  1. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study

    Directory of Open Access Journals (Sweden)

    Shyam K Saraf

    2013-01-01

    Full Text Available Background: The objective of this cadaveric study was to analyze the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of lower thoracic and lumbar pedicle screws. We also investigated the effect of bone mineral density (BMD, diameter of pedicle screws, and the region of spine on the pullout strength of pedicle screws. Materials and Methods: Sixty fresh human cadaveric vertebrae (D10-L2 were harvested. Dual-energy X-ray absorptiometry (DEXA scan of vertebrae was done for BMD. Titanium pedicle screws of different diameters (5.2 and 6.2 mm were inserted in the thoracic and lumbar segments after dividing the specimens into three groups: a standard pedicle screw (no cortical perforation; b screw with medial cortical perforation; and c screw with lateral cortical perforation. Finally, pullout load of pedicle screws was recorded using INSTRON Universal Testing Machine. Results: Compared with standard placement, medially misplaced screws had 9.4% greater mean pullout strength and laterally misplaced screws had 47.3% lesser mean pullout strength. The pullout strength of the 6.2 mm pedicle screws was 33% greater than that of the 5.2 mm pedicle screws. The pullout load of pedicle screws in lumbar vertebra was 13.9% greater than that in the thoracic vertebra ( P = 0.105, but it was not statistically significant. There was no significant difference between pullout loads of vertebra with different BMD ( P = 0.901. Conclusion: The mean pullout strength was less with lateral misplaced pedicle screws while medial misplaced pedicle screw had more pullout strength. The pullout load of 6.2 mm screws was greater than that of 5.2 mm pedicle screws. No significant correlation was found between bone mineral densities and the pullout strength of vertebra. Similarly, the pullout load of screw placed in thoracic and lumbar vertebrae was not significantly different.

  2. Design of three-dimensional visualization based on the posterior lumbar pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Kai XU

    2011-09-01

    Full Text Available Objective To establish a three-dimensional visualization model of posterior lumbar pedicle screw fixation.Methods A patient with lumbar intervertebral disc hernia and another patient with compression fracture of lumbar vertebra were involved in the present study.Both patients underwent multi-slice spiral CT scan before and after lumbar pedicle screw fixation.The degree of preoperative vertebral compression,vertebral morphology before and after surgery,postoperative pedicle screw position,and decompression effects were observed.The original data of the multi-slice spiral CT were inputted into the computer.The three-dimensional reconstructed images of the lumbar and implanted screws were obtained using the software Amira 4.1 to show the three-dimensional shape of the lumbar vertebrae before and after surgery and the location of the implanted screws.Results The morphology and structure of the lumbar vertebrae before and after surgery and of the implanted screws were reconstructed using the digital navigation platform.The reconstructed 3D images could be displayed in multicolor,transparent,or arbitrary combinations.In the 3D surface reconstruction images,the location and structure of the implanted screws could be clearly observed,and the decompression of the spinal cord or nerve roots and the severity of the fracture and the compression of lumbar vertebrae could be fully evaluated.The reconstructed images before operation revealed the position of the vertebral pedicles and provided reference for intraoperative localization.Conclusions The three-dimensional computerized reconstructions of lumbar pedicle screw fixation may be valuable in basic research,clinical experiment,and surgical planning.The software Amira is one of the bases of three-dimensional reconstruction.

  3. Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

    OpenAIRE

    Liu, Da; Zhang, Yi; Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming

    2013-01-01

    BACKGROUND: It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL FINDINGS: After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were random...

  4. [Polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis].

    Science.gov (United States)

    Sun, H L; Li, C D; Yang, Z C; Yi, X D; Liu, H; Lu, H L; Li, H; Wang, Y

    2016-12-18

    To describe the application of polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis. Observation group included 14 cases of degenerative lumbar diseases with osteoporosis received polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws from November 2014 to July 2015, control group included 12 cases of degenerative lumbar diseases with osteoporosis received polymethylmethacrylate augmentation with traditional pedicle screws.The operation time, blood loss, number of pedicle screws and number of augmented pedicle screws in the two groups were compared. The bone cement leakage and pulmonary bone cement embolism in the two groups were also compared. The fusion rate and pedicle screws loosening by lumbar X ray and dynamic X ray were evaluated. The clinical results were assessed by visual analog scale (VAS) of pain on lumbar and lower limbers, lumbar Japanese Orthopaedic Association scores (JOA), Prolo functional scores and Oswestry disability (ODI) scores. Differences of operation time and blood loss in the two groups were not statistically significant. The average number of pedicle screws was 9.9±4.7 and the average number of augmented pedicle screws was 5.9±2.6 in observation group while the average number of pedicle screws was 7.1±2.8 and the average number of augmented pedicle screws was 3.0±1.9 in control group. The ratio of augmented pedicle screws was higher in observation group than in control group (0.69±0.30 vs.0.47±0.30,Pdegenerative lumbar diseases with osteoporosis was effective, with simple working processes and lower risk of bone cement leakage. The short-term clinical result was good.

  5. Safety of lumbar spine radiofrequency procedures in the presence of posterior pedicle screws: technical report of a cadaver study.

    Science.gov (United States)

    Gazelka, Halena M; Welch, Tasha L; Nassr, Ahmad; Lamer, Tim J

    2015-05-01

    To determine whether the thermal energy associated with lumbar spine radiofrequency neurotomy (RFN) performed near titanium and stainless steel pedicle screws is conducted to the pedicle screws or adjacent tissues, or both, thus introducing potential for thermal damage to those tissues. Cadaver study. Cadaver laboratory equipped with fluoroscopy, surgical spine implements, and radiofrequency generator. No live human subject; a fresh frozen (and thawed) cadaver torso was used for the study. Titanium and stainless steel pedicle screws were placed in the lumbar spine of a fresh frozen cadaver torso with real-time fluoroscopic guidance. Conventional RFN cannula placement was performed at the level of pedicle screws and a control (nonsurgically altered) lumbar level. Neurotomy was performed with conventional radiofrequency lesioning parameters. Temperatures were recorded at multiple sites through thermistor probes. Direct contact of the radiofrequency cannula with the pedicle screws during conventional RFN produced a substantial increase in temperature in the surrounding soft tissues. A small increase in temperature occurred at the same sites at the control level. Titanium and stainless steel pedicle screws are capable of sustaining large increases in temperature when the radiofrequency probe comes in contact with the screw. These results are suggestive that pedicle screws could serve as a possible source of tissue heating and thermal injury during RFN. Wiley Periodicals, Inc.

  6. [Clinical efficacy of unilateral percutaneous transfacet screws combined with contralateral pedicle screw versus bilateral pedicle screws fixation in the treatment of the degenerative lumbar disease].

    Science.gov (United States)

    Hao, Rong-Xue; Zhou, Hui; Pan, Hao; Yue, Jun; Chen, Hui-Guo; Yang, He-Jie; Jia, Gao-Yong; Wang, Dong; Lin, Yan; Xu, Hua-Zi

    2017-09-25

    To investigate the surgical outcome of unilateral pedicle screw(UPS) after TLIF technique combined with contralateral percutaneous transfacet screw(PTS) fixation vs bilateral pedicle screws(BPS) fixation in treatment of degenerative lumbar disease. From January 2009 to June 2012, 46 patients with degenerative lumbar diseases, including 30 males and 16 females with an average age of 51.5 years old, who were divided into two groups according to different fixation methods. Twenty-two cases underwent UPS after TLIF technique combined with contralateral PTS fixation (group A), while the others underwent BPS fixation(group B). The relative data were analyzed, such as blood loss volume, operative time, fusion rate, ODI score, JOA score and so on. All the patients were followed up for 1 to 3 years with an average of 22 months. Except one case of each group was uncertainty fusion, the rest have obtained bony fusion, and the fusion rates in group A and B were 95.5% and 95.8%, respectively. No displacement and breakage of screw were found during follow-up. Operative time and blood loss volume in group A were better than of group B( P 0.05). Two approaches had similar clinical outcomes for degenerative lumbar disease with no severe instability. Compared with BPS fixation, the UPS after TLIF technique and contralateral PTS fixation has the advantages of less trauma, shorter operative time and less blood loss, and it is a safe and feasible surgical technique.

  7. [Effect evaluation of over 5 year follow up of unilateral pedicle screw fixation with transforaminal lumbar interbody fusion for lumbar degenerative diseases].

    Science.gov (United States)

    Wang, Chong; Ying, Jin-He; Xie, Pan-Pan; Wu, Xiao-Guang

    2016-07-25

    To evaluate the clinical effects of over 5 year follow up of unilateral pedicle screw fixation with transforaminal lumbar interbody fusion(TLIF) in treating lumbar degenerative diseases. The clinical data of 24 patients with lumbar degenerative disease underwent unilateral pedicle screw fixation with transforaminal lumbar interbody fusion from March 2007 to October 2009, were retrospectively analyzed. There were 13 males and 11 females, aged from 34 to 68 years old with an average of 52 years. Postoperative pain and functional results were analyzed by the visual analogue scale(VAS) and Oswestry Disability Index(ODI). Radiological examination was obtained for each patient to assess the height of intervertebral space, postoperative intervertebral fusion conditions and general complications. All patients were followed up from 5 to 8 years with an average of 6.7 years. VAS scores of low back pain and leg pain decreased from preoperative 7.82±0.71, 8.42±1.24 to postoperative 1.87±0.81, 2.23±1.62, respectively( P degenerative diseases according to over 5 year follow up, however, its indications should be well considered. But the problems such as intervertebral space height of operated side loss and adjacent segment degeneration after unilateral pedicle screw fixation need further clinical study.

  8. Adjacent-segment disease after thoracic pedicle screw fixation.

    Science.gov (United States)

    Agarwal, Nitin; Heary, Robert F; Agarwal, Prateek

    2018-03-01

    OBJECTIVE Pedicle screw fixation is a technique widely used to treat conditions ranging from spine deformity to fracture stabilization. Pedicle screws have been used traditionally in the lumbar spine; however, they are now being used with increasing frequency in the thoracic spine as a more favorable alternative to hooks, wires, or cables. Although safety concerns, such as the incidence of adjacent-segment disease (ASD) after cervical and lumbar fusions, have been reported, such issues in the thoracic spine have yet to be addressed thoroughly. Here, the authors review the literature on ASD after thoracic pedicle screw fixation and report their own experience specifically involving the use of pedicle screws in the thoracic spine. METHODS Select references from online databases, such as PubMed (provided by the US National Library of Medicine at the National Institutes of Health), were used to survey the literature concerning ASD after thoracic pedicle screw fixation. To include the authors' experience at Rutgers New Jersey Medical School, a retrospective review of a prospectively maintained database was performed to determine the incidence of complications over a 13-year period in 123 consecutive adult patients who underwent thoracic pedicle screw fixation. Children, pregnant or lactating women, and prisoners were excluded from the review. By comparing preoperative and postoperative radiographic images, the occurrence of thoracic ASD and disease within the surgical construct was determined. RESULTS Definitive radiographic fusion was detected in 115 (93.5%) patients. Seven incidences of instrumentation failure and 8 lucencies surrounding the screws were observed. One patient was observed to have ASD of the thoracic spine. The mean follow-up duration was 50 months. CONCLUSIONS This long-term radiographic evaluation revealed the use of pedicle screws for thoracic fixation to be an effective stabilization modality. In particular, ASD seems to be less of a problem in the

  9. Transforaminal lumbar interbody fusion using unilateral pedicle screw fixation plus contralateral translaminar facet screw fixation in lumbar degenerative diseases.

    Science.gov (United States)

    Liu, Fubing; Jiang, Chun; Cao, Yuanwu; Jiang, Xiaoxing; Feng, Zhenzhou

    2014-07-01

    Transforaminal lumbar interbody fusion (TLIF) has been used in lumbar degenerative diseases. Some researchers have applied unilateral fixation in TLIF to reduce operational trauma without compromising the clinical outcome, but it is always suspected biomechanically unstable. The supplementary contralateral translaminar facet screw (cTLFS) seemed to be able to overcome the inherent drawbacks of unilateral pedicle screw (uPS) fixation theoretically. This study evaluates the safety, feasibility and efficacy of TLIF using uPS with cTLFS fixation in the treatment of lumbar degenerative diseases (LDD). 50 patients (29 male) underwent the aforementioned surgical technique for their LDD between December 2009 and April 2012. The results were evaluated based on visual analogue scale (VAS) of the leg and back, Japanese Orthopedic Association (JOA) score and Oswestry Disability Index (ODI) were recorded. The radiographic examinations in form of X-ray, computed tomography (CT) or magnetic resonance imaging was done preoperatively and 1 week, 3 months, 6 months, 12 months and 24 months postoperatively. The student t-test was used for comparison between the preoperative values and postoperative counterparts. P degenerative diseases short termly.

  10. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    Directory of Open Access Journals (Sweden)

    William D. Harrison

    2013-01-01

    Full Text Available Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf.

  11. Undertapping of Lumbar Pedicle Screws Can Result in Tapping With a Pitch That Differs From That of the Screw, Which Decreases Screw Pullout Force.

    Science.gov (United States)

    Bohl, Daniel D; Basques, Bryce A; Golinvaux, Nicholas S; Toy, Jason O; Matheis, Erika A; Bucklen, Brandon S; Grauer, Jonathan N

    2015-06-15

    Survey of spine surgeons and biomechanical comparison of screw pullout forces. To investigate what may be a suboptimal practice regularly occurring in spine surgery. In order for a tap to function in its intended manner, the pitch of the tap should be the same as the pitch of the screw. Undertapping has been shown to increase the pullout force of pedicle screws compared with line-to-line tapping. However, given the way current commercial lumbar pedicle screw systems are designed, undertapping may result in a tap being used that has a different pitch from that of the screw (incongruent pitch). A survey asked participants questions to estimate the proportion of cases each participant performed in the prior year using various hole preparation techniques. Participant responses were interpreted in the context of manufacturing specifications of specific instrumentation systems. Screw pullout forces were compared between undertapping with incongruent pitch and undertapping with congruent pitch using 0.16 g/cm polyurethane foam block and 6.5-mm screws. Of the 3679 cases in which participants reported tapping, participants reported line-to-line tapping in 209 cases (5%), undertapping with incongruent pitch in 1156 cases (32%), and undertapping with congruent pitch in 2314 cases (63%). The mean pullout force for undertapping with incongruent pitch was 56 N (8%) less than the mean pullout force for undertapping with congruent pitch. This is equivalent to 13 lb. This study estimates that for about 1 out of every 3 surgical cases with tapping of lumbar pedicle screws in the United States, hole preparation is being performed by undertapping with incongruent pitch. This study also shows that undertapping with incongruent pitch results in a decrease in pullout force by 8% compared with undertapping with congruent pitch. Steps should be taken to correct this suboptimal practice. 3.

  12. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.

    Science.gov (United States)

    Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N

    2015-08-01

    We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.

  13. Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.

    Science.gov (United States)

    Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung

    2010-01-01

    Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.

  14. Image Guidance to Aid Pedicle Screw Fixation of a Lumbar Fracture-Dislocation Injury in a Toddler.

    Science.gov (United States)

    Houten, John K; Nahkla, Jonathan; Ghandi, Shashank

    2017-09-01

    Pedicle screw fixation of the lumbar spine in children age <2 years is particularly challenging, as successful cannulation of the small pedicle dimensions requires a high level of precision and there are no implants specifically designed for the infant spine. Image-guided navigation is commonly used in adult spinal surgery and may be particularly helpful for the placement of spinal screws in areas where the bony anatomy is small and/or anatomically complex, as in the upper cervical area. A 19-month-old female presented with a fracture-dislocation injury of L1-2. Intraoperative imaging using the O-arm multidimensional imaging system was networked to a workstation, and neuronavigation was used to place pedicle instrumentation with 3.5-mm-diameter polyaxial screws designed for posterior cervical fixation. At a 48-month follow-up, the patient was neurologically intact, demonstrated normal physical development, and was engaging in normal physical activity for her age. Radiographs obtained approximately 4 years postsurgery showed no evidence of loss for fixation. Image-guided placement of pedicle screws may be a useful aid in achieving accurate and safe fixation in the small dimensions of the infant spine. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Treatment of degenerative lumbar spondylolisthesis by using minimally invasive transforaminal lumbar interbody fusion and percutaneous pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Hao WU

    2016-04-01

    Full Text Available Objective To discuss clinical therapeutic effects of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF combined with percutaneous pedicle screw fixation for degenerative lumbar spondylolisthesis (DLS.  Methods A total of 32 DLS patients treated by MIS-TLIF and percutaneous pedicle screw fixation from January 2013 to September 2015 in Xuanwu Hospital, Capital Medical University were retrospectively reviewed. Visual Analogue Scale (VAS, Oswestry Disability Index (ODI and Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36 scores were assessed and compared between preoperation and one week, 3 months after operation and in the last follow-up. Lumbar lordosis angle, coronal Cobb angle, coronal and sagittal body shifting, complication, the degree of spondylolisthesis (Meyerding classification and the rate of spondylolisthesis were measured according to preoperative and postoperative spinal X-ray examination. Fusion rate was evaluated according to X-rays or CT in the last follow-up, and MRI was used to assess the degree of decompression.  Results Thirty-two patients were under test with mean operation time 160 min, intraoperative blood loss 120 ml, postoperative hospital stay 7.22 d and follow-up 10.83 months. Decompression and fusion levels ranged from L2-S1 and interbody fusion was performed in 32 patients and 41 levels were fused. Compared with preoperation, the VAS and ODI scores were significantly increased at one week, 3 months after operation and in the last follow-up (P = 0.000, for all, while SF-36 score (P = 0.002, 0.000, 0.000, lumbar lordotic angle (P = 0.000, for all, coronal Cobb angle (P = 0.000, for all and slippage rate (P = 0.000, for all were significantly decreased. The fusion rate was 92.22%, and the improvement rate of ODI was (80.51 ± 6.02% in the last follow-up. There were 3 cases appeared complications, including one case of infection and 2 cases of cerebrospinal fluid (CSF fistula, and were

  16. Pull out Strength of Dual Outer Diameter Pedicle Screws Compared to Uncemented and Cemented Standard Pedicle Screws: A Biomechanical in vitro Study.

    Science.gov (United States)

    Lorenz, Andrea; Leichtle, Carmen I; Frantz, Sandra; Bumann, Marte; Tsiflikas, Ilias; Shiozawa, Thomas; Leichtle, Ulf G

    2017-05-01

    To analyze the potential of the dual outer diameter screw and systematically evaluate the pull-out force of the dual outer diameter screw compared to the uncemented and cemented standard pedicle screws with special regard to the pedicle diameter and the vertebra level. Sixty vertebrae of five human spines (T 6 -L 5 ) were sorted into three study groups for pairwise comparison of the uncemented dual outer diameter screw, the uncemented standard screw, and the cemented standard screw, and randomized with respect to bone mineral density (BMD) and vertebra level. The vertebrae were instrumented, insertion torque was determined, and pull-out testing was performed using a material testing machine. Failure load was evaluated in pairwise comparison within each study group. The screw-to-pedicle diameter ratio was determined and the uncemented dual outer diameter and standard screws were compared for different ratios as well as vertebra levels. Significantly increased pull-out forces were measured for the cemented standard screw compared to the uncemented standard screw (+689 N, P dual outer diameter screw (+403 N, P dual outer diameter screw to the uncemented standard screw in the total study group, a distinct but not significant increase was measured (+149 N, P = 0.114). Further analysis of these two screws, however, revealed a significant increase of pull-out force for the dual outer diameter screw in the lumbar region (+247 N, P = 0.040), as well as for a screw-to-pedicle diameter ratio between 0.6 and 1 (+ 488 N, P = 0.028). For clinical application, cement augmentation remains the gold standard for increasing screw stability. According to our results, the use of a dual outer diameter screw is an interesting option to increase screw stability in the lumbar region without cement augmentation. For the thoracic region, however, the screw-to-pedicle diameter should be checked and attention should be paid to screw cut out, if the dual outer diameter screw is considered.

  17. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.

    Science.gov (United States)

    Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner

    2018-03-01

    Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3  ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3  ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard

  18. MIS Single-position Lateral and Oblique Lateral Lumbar Interbody Fusion and Bilateral Pedicle Screw Fixation: Feasibility and Perioperative Results.

    Science.gov (United States)

    Blizzard, Daniel J; Thomas, J Alex

    2018-03-15

    Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with

  19. [Direct repair of adolescent lumbar spondylolysis using a pedicle screw-laminar hook system by paramedian approach].

    Science.gov (United States)

    Wang, Bin; Tang, Yong-hua; Tang, Hong-chao; Jin, Cai-yi

    2011-08-01

    To discuss the indication and clinical effect of direct repair of adolescent lumbar spondylolysis by screw-laminar hook system. From August 2003 to December 2008, 28 patients (13 males and 15 females,ranging in age from 15 and 26 years, averaged 21.6 years) with lumbar spondylolysis were treated with isthmic bone grafting and internal fixation with a pedicle screw-laminar hook system. Three patients had spondylolysis at L3, L4; 5 patients had spondylolysis at L4, L5; 8 patients had spondylolysis at L4; and 12 patients had spondylolysis at L5. All the patients had low back pain and lasted over 6 months. According to preoperative and postoperative plain radiograph, CT scan and Macnab criteria, the fusion rate and clinical effect of this technique were evaluated. All the patients were followed up with a mean period of 14.9 months, ranging from 9 to 24 months. All the patients had bony union according to the X-rays and CT scan. According to the calculation results of Macnab criteria, 22 patients got an excellent result, 5 good and 1 fair. The direct repair of adolescent lumbar spondylolysis with pedicle screw-laminar hook system can shorten length of operation,decrease blood loss, preserve more posterior structures of spine and avoid iatrogenic instability of spine. The postoperative immediate stability of vertebral segment is acquired and the mobility of adjacent intervertebral discs is reserved. The screw-laminar hook system for the treatment of adolescent spondylolisthesis can get satisfactory clinical results.

  20. [Effectiveness of posterior intrasegmental fixation with pedicle screw-lamina hook system in treatment of lumbar spondylolysis].

    Science.gov (United States)

    Zhou, Zhongjie; Song, Yueming; Zeng, Jiancheng; Liu, Hao; Liu, Limin; Kong, Qingquan; Li, Tao; Gong, Quan

    2013-03-01

    To investigate the effectiveness of posterior intrasegmental fixation with pedicle screw-lamina hook system and bone grafting for lumbar spondylolysis. Between January 2005 and October 2009, 22 patients with lumbar spondylolysis underwent posterior intrasegmental fixation with pedicle screw-lamina hook system and bone grafting. There were 19 males and 3 females with an average age of 18.4 years (range, 12-26 years). The main symptom was low back pain with an average disease duration of 16 months (range, 8-56 months). The visual analogue scale (VAS) was 6.0 +/- 1.2 and Oswestry disability index (ODI) was 72.0% +/- 10.0% preoperatively. The X-ray films showed bilateral spondylolysis at L4 in 9 cases and at L5 in 13 cases. The range of motion (ROM) at upper and lower intervertebral spaces was (11.8 +/- 2.8) degrees and (14.1 +/- 1.9) degrees, respectively. All incisions healed by first intention. All patients were followed up 12-45 months (mean, 25 months). Low back pain was significantly alleviated after operation. The VAS score (0.3 +/- 0.5) and ODI (17.6% +/- 3.4%) were significantly decreased at last follow-up when compared with preoperative scores (P spondylolysis, having a high fusion rate, low complication rate, and maximum retention of lumbar ROM.

  1. A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine.

    Science.gov (United States)

    Merc, Matjaz; Drstvensek, Igor; Vogrin, Matjaz; Brajlih, Tomaz; Recnik, Gregor

    2013-07-01

    The method of free-hand pedicle screw placement is generally safe although it carries potential risks. For this reason, several highly accurate computer-assisted systems were developed and are currently on the market. However, these devices have certain disadvantages. We have developed a method of pedicle screw placement in the lumbar and sacral region using a multi-level drill guide template, created with the rapid prototyping technology and have validated it in a clinical study. The aim of the study was to manufacture and evaluate the accuracy of a multi-level drill guide template for lumbar and first sacral pedicle screw placement and to compare it with the free-hand technique under fluoroscopy supervision. In 2011 and 2012, a randomized clinical trial was performed on 20 patients. 54 screws were implanted in the trial group using templates and 54 in the control group using the fluoroscopy-supervised free-hand technique. Furthermore, applicability for the first sacral level was tested. Preoperative CT-scans were taken and templates were designed using the selective laser sintering method. Postoperative evaluation and statistical analysis of pedicle violation, displacement, screw length and deviation were performed for both groups. The incidence of cortex perforation was significantly reduced in the template group; likewise, the deviation and displacement level of screws in the sagittal plane. In both groups there was no significantly important difference in deviation and displacement level in the transversal plane as not in pedicle screw length. The results for the first sacral level resembled the main investigated group. The method significantly lowers the incidence of cortex perforation and is therefore potentially applicable in clinical practice, especially in some selected cases. The applied method, however, carries a potential for errors during manufacturing and practical usage and therefore still requires further improvements.

  2. Biomechanical comparative study of the stability of injectable pedicle screws with different lateral holes augmented with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae.

    Science.gov (United States)

    Liu, Da; Sheng, Jun; Luo, Yang; Huang, Chen; Wu, Hong-Hua; Zhou, Jiang-Jun; Zhang, Xiao-Jun; Zheng, Wei

    2018-03-19

    Polymethylmethacrylate (PMMA) is widely used for pedicle screw augmentation in osteoporosis. Until now, there had been no studies of the relationship between screw stability and the distribution and volume of PMMA. The objective of this study was to analyze the relationship between screw stability and the distribution pattern and injected volume of PMMA. This is a biomechanical comparison of injectable pedicle screws with different lateral holes augmented with different volumes of PMMA in cadaveric osteoporotic lumbar vertebrae. Forty-eight osteoporotic lumbar vertebrae were randomly divided into Groups A, B, and C with different pedicle screws (16 vertebrae in each group), and then each group was randomly divided into Subgroups 0, 1, 2, and 3 with different volumes of PMMA (four vertebra with eight pedicles in each subgroup). A pilot hole was prepared in advance using the same method in all samples. Type A and type B pedicle screws were directly inserted into vertebrae in Groups A and B, respectively, and then different volumes of PMMA (0, 1.0, 1.5, and 2.0 mL) were injected through the screws and into vertebrae in Subgroups 0, 1, 2, and 3. The pilot holes were filled with different volumes of PMMA (0, 1.0, 1.5, and 2.0 mL), and then the screws were inserted in Groups C0, C1, C2, and C3. Screw position and distribution of PMMA were evaluated radiographically, and axial pullout tests were performed to measure maximum axial pullout strength (F max ). Polymethylmethacrylate surrounded the anterior one-third of screws in the vertebral body in Groups A1, A2, and A3; the middle one-third of screws in the junction area of the vertebral body and the pedicle in Groups B1, B2, and B3; and the full length of screws evenly in both the vertebral body and the pedicle in Groups C1, C2, and C3. There was no malpositioning of screws or leakage of PMMA in any sample. Two-way analysis of variance revealed that two factors-distribution and volume of PMMA-significantly influenced

  3. Clinical efficacy of bone cement injectable pedicle screw system combined with intervertebral fusion in treatment of lumbar spondylolysis and osteoporosis

    Directory of Open Access Journals (Sweden)

    Peng-yi DAI

    2016-10-01

    Full Text Available Objective  To observe the therapeutic effect of bone cement injectable pedicle screw system combined with intervertebral fusion for lumbar spondylolysis and osteoporosis. Methods  The clinical data were analyzed retrospectively of 21 patients with lumbar spondylolysis and osteoporosis who received treatment of bone cement injectable pedicle screw system and intervertebral fusion from Aug. 2013 to Nov. 2015. The 21 patients (9 males and 12 females aged from 60 to 80 years (mean 64 years old; 6 of them presented degenerative spondylolysis, 15 with isthmic spondylolisthesis; 2 cases had I degree slippage, 13 had Ⅱdegree slippage, 6 had Ⅲdegree slippage, and all the cases were unisegmental slippage including 9 cases in L4 and 12 cases in L5. Bone mineral density of lumbar vertebrae (L2-L5 was measured with dual-energy X-ray absorptiometry, and T values conforming to the diagnostic criteria of osteoporosis were less than or equal to -2.5; All patients were operated with whole lamina resection for decompression, bone cement injectable pedicle screws system implantation, propped open reduction and fixation intervertebral fusion. The clinical outcomes were determined by the radiographic evaluation including intervertebral height, height of intervertebral foramen, slip distance, slip rate and slip angle, and Oswestry disability index (ODI on preoperative, 3 months after operation and the end of the time, and the interbody fusion were followed up. Results  Cerebrospinal fluid leakage of incision was observed in two cases after operation, compression and dressing to incision, Trendelenburg position, dehydration and other treatments were taken, and the stitches of incisions were taken out on schedule. Slips in the 21 patients were reset to different extent, and lumbar physiological curvatures were recovered. The intervertebral height and height of intervertebral foramen were obviously higher 3 months after operation than that before operation (P0

  4. [Clinical application of accurate placement of lumbar pedicle screws using three-dimensional printing navigational templates under Quadrant system].

    Science.gov (United States)

    Chen, Xuanhuang; Yu, Zhengxi; Wu, Changfu; Li, Xing; Chen, Xu; Zhang, Guodong; Zheng, Zugao; Lin, Haibin

    2017-02-01

    To explore the feasibility and the effectiveness of the accurate placement of lumbar pedicle screws using three-dimensional (3D) printing navigational templates in Quadrant minimally invasive system. The L 1-5 spines of 12 adult cadavers were scanned using CT. The 3D models of the lumbar spines were established. The screw trajectory was designed to pass through the central axis of the pedicle by using Mimics software. The navigational template was designed and 3D-printed according to the bony surface where the soft tissues could be removed. The placed screws were scanned using CT to create the 3D model again after operation. The 3D models of the designed trajectory and the placed screws were registered to evaluate the placed screws coincidence rate. Between November 2014 and November 2015, 31 patients with lumbar instability accepted surgery assisted with 3D-printing navigation module under Quadrant minimally invasive system. There were 14 males and 17 females, aged from 42 to 60 years, with an average of 45.2 years. The disease duration was 6-13 months (mean, 8.8 months). Single segment was involved in 15 cases, two segments in 13 cases, and three segments in 3 cases. Preoperative visual analogue scale (VAS) was 7.59±1.04; Oswestry disability index (ODI) was 76.21±5.82; and the Japanese Orthopaedic Association (JOA) score was 9.21±1.64. A total of 120 screws were placed in 12 cadavers specimens. The coincidence rate of placed screw was 100%. A total of 162 screws were implanted in 31 patients. The operation time was 65-147 minutes (mean, 102.23 minutes); the intraoperative blood loss was 50-116 mL (mean, 78.20 mL); and the intraoperative radiation exposure time was 8-54 seconds (mean, 42 seconds). At 3-7 days after operation, CT showed that the coincidence rate of the placed screws was 98.15% (159/162). At 4 weeks after operation, VAS, ODI, and JOA score were 2.24±0.80, 29.17±2.50, and 23.43±1.14 respectively, showing significant differences when compared

  5. Surgical outcome of posterior lumbar interbody fusion with pedicle screw fixation for lumbar spondylolisthesis

    International Nuclear Information System (INIS)

    Shoda, Motoi; Kuno, Shigehiko; Inoue, Tatsushi

    2009-01-01

    Problems of lumbar spondylolisthesis treatment are many surgical tactics, elderly patient, osteoporosis, complications and recurrence of the symptoms. PLIF (posterior lumbar interbody fusion) and PS (pedicle screw) fixation technique for lumbar spondylolisthesis provide good patient satisfaction. Good outcome has been reported by only laminectomy alone, but patient satisfaction becomes worse year after year. The role of instrumentation for lumbar spondylolisthesis is decompression of the nerve root, correction of lumbar pathologies, bony fusion and early mobilization. We show our surgical technique and long term outcome of PLIF with PS for lumbar spondylolisthesis. Three hundred and fifty cases of lumbar spondylolisthesis were operated on in Department of Neurosurgery, Fujita Health University during the period of from December 1992 to August 2008. Patient background: age 16-84 years old (mean 62.5), Gender: male 153, female 197. Follow-up period 1-180 months (mean 61.2). Degenerative: 255, Isthmic: 63, Dysplastic: 10, Fracture: 5 and scoliosis 16 cases. Surgical procedure was PS with interbody fusion cage: 331, Hybrid cage (titanium cage with hydroxyapatite) 314, PS with Cerabone: 2 and PS with autograft: 17. CT was done to evaluate bony fusion postoperatively. Post operative improvements by JOA (Japan Orthopedic Association) score is 11.4 before surgery, 24.1 (post op. within 2 years), 25.4 (post op. 2-5 years), 25.0 (post op. 5-10 years) and 22.4 (post op. 10-15 years). Significant improvements were observed in %Slip and Slip angle but no remarkable change was observed in lumbar lordotic angle by postoperative X-ray evaluation. No root injury, and systemic complication except 4 cases of cerebrospinal fluid (CSF) leakage during surgery. Two cases were reoperated in whom cage with autograft migration due to pseudoarthrosis. Two cases had to undergo screw and cage system removal due to infection. Two cases of adjacent level stenosis had to undergo operation 10

  6. Clinical study on minimally invasive transforaminal lumbar interbody fusion combined with percutaneous pedicle screw fixation for degenerative lumbar scoliosis

    Directory of Open Access Journals (Sweden)

    Hao WU

    2016-04-01

    Full Text Available Objective To discuss the operative essentials and therapeutic effects of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF combined with percutaneous pedicle screw fixation for degenerative lumbar scoliosis (DLS.  Methods A total of 17 DLS patients without prior spinal diseases were treated by MIS-TLIF and percutaneous pedicle screw fixation from January 2013 to September 2015 in Xuanwu Hospital, Capital Medical University. The operation time, intraoperative blood loss, hospital stay, and postoperative complication were recorded in each patient. Visual Analogue Scale (VAS and Oswestry Disability Index (ODI were used to evaluate postoperative improvement of low back and leg pain, and clinical effects were assessed according to Medical Outcome Study 36-Item Short-Form Health Survey (SF-36. Coronal Cobb angle, sagittal lordosis angle and spinal deviation distances on coronal and sagittal plane were measured before operation, one week, 3 months after operation and in the last follow-up in spinal full-length X-ray examination. Fusion rate was calculated according to X-ray or CT scan, and the degree of decompression was evaluated by MRI.  Results Decompression and fusion levels ranged from T12-S1 vertebrae, and interbody fusion was performed in 17 patients and 56 levels were fused. Average operation time was 200 min (180-300 min, intraoperative blood loss was 320 ml (200-1000 ml and hospital stay was 8.21 d (5-12 d. All patients were followed-up for 12.13 months (5-24 months. Compared with preoperation, VAS (P = 0.000, for all and ODI scores (P = 0.000, for all decreased significantly, SF-36 score increased (P = 0.000, for all, coronal Cobb angle (P = 0.000, for all, sagittal lordosis angle (P = 0.000, for all, coronal and sagittal deviation (P = 0.000, for all decreased significantly one week and 3 months after operation and in the last follow-up. The improvement rate of ODI was (86.51 ± 6.02%, fusion rate of vertebral bodies

  7. Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation. Short-term observation

    International Nuclear Information System (INIS)

    Mizuno, Koichi; Shinomiya, Kenichi; Otani, Kazuyuki

    2005-01-01

    The correlation between the insertion torque of a lumbar pedicle screw and the mechanical stability of the screw in the bone has been mentioned in in vitro studies. The purpose of this study was to confirm the factors affecting the insertion torque of such screws in vivo. Also, the contribution of insertion torque to the initial stability of the fusion area was to be analyzed in vivo. A series of 23 cases representing 50 lumbar vertebrae were included in this study, in which we examined bone mineral density using quantitative computed tomography (CT) prior to operation. Two screw shapes were utilized, with the insertion torque for each screw measured at two points in time. The correlation between insertion torque and mineral density was investigated. Screw positions were confirmed on postoperative CT scans, and the effect of the screw thread cutting into the cortex bone was investigated. Radiographic changes at three points during a period of 3 months were also measured, and we then evaluated the interrelations between these changes and insertion torque. Furthermore, the relation between insertion torque and instability at 3 months was investigated. Correlations of insertion torque and bone mineral density depended on screw shape. There was no correlation found with mineral density in the case of cylindrical screws. Insertion torque was not affected by the screw thread cutting into the cortex of bone. As for postoperative alignment changes, no definitive trends could be ascertained, and no interrelations with torque and alignment changes were observed. There is a possibility that insertion torque was related to early-stage stability, but no statistical relation could be determined. (author)

  8. EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.

    Science.gov (United States)

    Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido

    2010-01-01

    To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.

  9. Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing.

    Directory of Open Access Journals (Sweden)

    Sophie Le Cann

    Full Text Available The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to optimize pedicle screw fixation in the porcine model, this study evaluates ex vivo the impact of weight (age of the animal, the level of the vertebrae (lumbar or thoracic and the type of screw anchorage (mono- or bi-cortical on pedicle screw pullouts. Among the 80 pig vertebrae (90- and 140-day-old tested in this study, the average screw pullout forces ranged between 419.9N and 1341.2N. In addition, statistical differences were found between test groups, pointing out the influence of the three parameters stated above. We found that the the more caudally the screws are positioned (lumbar level, the greater their pullout resistance is, moreover, screw stability increases with the age, and finally, the screws implanted with a mono-cortical anchorage sustained lower pullout forces than those implanted with a bi-cortical anchorage. We conclude that the best anchorage can be obtained with older animals, using a lumbar fixation and long screws traversing the vertebra and inducing bi-cortical anchorage. In very young animals, pedicle screw fixations need to be bi-cortical and more numerous to prevent pullout.

  10. Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing.

    Science.gov (United States)

    Le Cann, Sophie; Cachon, Thibaut; Viguier, Eric; Miladi, Lotfi; Odent, Thierry; Rossi, Jean-Marie; Chabrand, Patrick

    2015-01-01

    The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to optimize pedicle screw fixation in the porcine model, this study evaluates ex vivo the impact of weight (age) of the animal, the level of the vertebrae (lumbar or thoracic) and the type of screw anchorage (mono- or bi-cortical) on pedicle screw pullouts. Among the 80 pig vertebrae (90- and 140-day-old) tested in this study, the average screw pullout forces ranged between 419.9N and 1341.2N. In addition, statistical differences were found between test groups, pointing out the influence of the three parameters stated above. We found that the the more caudally the screws are positioned (lumbar level), the greater their pullout resistance is, moreover, screw stability increases with the age, and finally, the screws implanted with a mono-cortical anchorage sustained lower pullout forces than those implanted with a bi-cortical anchorage. We conclude that the best anchorage can be obtained with older animals, using a lumbar fixation and long screws traversing the vertebra and inducing bi-cortical anchorage. In very young animals, pedicle screw fixations need to be bi-cortical and more numerous to prevent pullout.

  11. Experimental study of pedicle screw stability on low BMD vertebrae

    International Nuclear Information System (INIS)

    Li Qi; Yang Huilin; Tang Tiansi; Wu Yiwei; Wang Yijin

    2005-01-01

    Objective: To conduct biomechanical study of different pedicle screws stability on spinal specimen, discuss the relationship between design parameter of screw, insertion torgue and BMD, establish the theoretical foundation for application of pedicle screw on osteoporotic patients. Methods: Six fixed lumbar cadavers were collected, the effects of design parameter, insertion torque and etc on fixation stability were determined under various BMD by using biomechanical ways. Results: According to in vitro study: (1) There was a significant difference among pullout strength of all screws (P 2 >U 1 >SF 1 >SF 2 >RF. Conclusions: There is a close correlated between type of screw, BMD and stability. The U-type screw displays the best fixation effect on specimen of low BMD. (authors)

  12. A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine.

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    Full Text Available Technical developments for improving the safety and accuracy of pedicle screw placement play an increasingly important role in spine surgery. In addition to the standard techniques of free-hand placement and fluoroscopic navigation, the rate of complications is reduced by 3D fluoroscopy, cone-beam CT, intraoperative CT/MRI, and various other navigation techniques. Another important aspect that should be emphasized is the reduction of intraoperative radiation exposure for personnel and patient. The aim of this study was to investigate the accuracy of a new navigation system for the spine based on an electromagnetic field.Twenty pedicle screws were placed in the lumbar spine of human cadavers using EMF navigation. Navigation was based on data from a preoperative thin-slice CT scan. The cadavers were positioned on a special field generator and the system was matched using a patient tracker on the spinous process. Navigation was conducted using especially developed instruments that can be tracked in the electromagnetic field. Another thin-slice CT scan was made postoperatively to assess the result. The evaluation included the position of the screws in the direction of trajectory and any injury to the surrounding cortical bone. The results were classified in 5 groups: grade 1: ideal screw position in the center of the pedicle with no cortical bone injury; grade 2: acceptable screw position, cortical bone injury with cortical penetration ≤ 2 mm; grade 3: cortical bone injury with cortical penetration 2,1-4 mm, grad 4: cortical bone injury with cortical penetration 4,1-6 mm, grade 5: cortical bone injury with cortical penetration >6 mm.The initial evaluation of the system showed good accuracy for the lumbar spine (65% grade 1, 20% grade 2, 15% grade 3, 0% grade 4, 0% grade 5. A comparison of the initial results with other navigation techniques in literature (CT navigation, 2D fluoroscopic navigation shows that the accuracy of this system is

  13. Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

    Directory of Open Access Journals (Sweden)

    Lutz Weise

    2008-10-01

    Full Text Available Lutz Weise, Olaf Suess, Thomas Picht, Theodoros KombosNeurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, GermanyObjective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker. The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326. In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more was 3.37% (11/326. Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforation

  14. Lumbar pedicle screw placement: Using only AP plane imaging

    Directory of Open Access Journals (Sweden)

    Anil Sethi

    2012-01-01

    Conclusion: Placement of pedicle screws under fluoroscopic guidance using AP plane imaging alone with tactile guidance is safe, fast, and reliable. However, a good understanding of the radiographic landmarks is a prerequisite.

  15. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    Science.gov (United States)

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  16. The pullout performance of pedicle screws

    CERN Document Server

    Demir, Teyfik

    2015-01-01

    This brief book systematically discusses all subjects that affect the pullout strength of pedicle screws. These screws are used in spinal surgeries to stabilize the spine. The holding strength of the pedicle screw is vital since loosening of the pedicle screws can cause revision surgeries. Once the pedicle screw is pulled out, it is harder to obtain same stabilization for the fused vertebrae. The book reviews the effect of screw designs, application techniques, cement augmentation, coating of the screw and test conditions on the pullout strength. The studies with finite element analysis were also included.

  17. Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training.

    Science.gov (United States)

    Park, Hyun Jin; Wang, Chenyu; Choi, Kyung Ho; Kim, Hyong Nyun

    2018-04-16

    Training beginners of the pedicle screw instrumentation technique in the operating room is limited because of issues related to patient safety and surgical efficiency. Three-dimensional (3D) printing enables training or simulation surgery on a real-size replica of deformed spine, which is difficult to perform in the usual cadaver or surrogate plastic models. The purpose of this study was to evaluate the educational effect of using a real-size 3D-printed spine model for training beginners of the free-hand pedicle screw instrumentation technique. We asked whether the use of a 3D spine model can improve (1) screw instrumentation accuracy and (2) length of procedure. Twenty life-size 3D-printed lumbar spine models were made from 10 volunteers (two models for each volunteer). Two novice surgeons who had no experience of free-hand pedicle screw instrumentation technique were instructed by an experienced surgeon, and each surgeon inserted 10 pedicle screws for each lumbar spine model. Computed tomography scans of the spine models were obtained to evaluate screw instrumentation accuracy. The length of time in completing the procedure was recorded. The results of the latter 10 spine models were compared with those of the former 10 models to evaluate learning effect. A total of 37/200 screws (18.5%) perforated the pedicle cortex with a mean of 1.7 mm (range, 1.2-3.3 mm). However, the latter half of the models had significantly less violation than the former half (10/100 vs. 27/100, p 3D-printed spine model can be an excellent tool for training beginners of the free-hand pedicle screw instrumentation.

  18. Minimally invasive mini open split-muscular percutaneous pedicle screw fixation of the thoracolumbar spine

    Directory of Open Access Journals (Sweden)

    Murat Ulutaş

    2015-03-01

    Full Text Available We prospectively assessed the feasibility and safety of a new percutaneous pedicle screw (PPS fixation technique for instrumentation of the thoracic and lumbar spine in this study. All patients were operated in the prone position under general anesthesia. A 6 to 8 cm midline skin incision was made and wide sub-cutaneous dissection was performed. The paravertebral muscles were first dissected subperiosteally into the midline incision of the fascia for lumbar microdiscectomy with transforaminal lumbar interbody fusion cage implantation. After the secondary paramedian incisions on the fascia, the PPSs were inserted via cleavage of the multifidus muscles directly into the pedicles under fluoroscopy visualization. A total of 35 patients underwent surgery with this new surgical technique. The control group for operative time, blood loss and analgesic usage consisted of 35 randomly selected cases from our department. The control group underwent surgery via conventional pedicle screw instrumentation with paramedian fusion. All patients in the minimal invasive surgery series were ambulatory with minimal pain on the first postoperative day. The operation time and blood loss and the postoperative analgesic consumption were significantly less with this new technique. In conclusion, the minimal invasive mini open split-muscular percutaneous pedicle screw fixation technique is safe and feasible. It can be performed via a short midline skin incision and can also be combined with interbody fusion, causing minimal pain without severe muscle damage.

  19. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary

  20. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L.; Booz, Christian; Bauer, Ralf W.; Kerl, J.M.; Fischer, Sebastian; Lehnert, Thomas; Vogl, Thomas J.; Khan, M.F. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wesarg, Stefan [Fraunhofer IGD, Cognitive Computing and Medical Imaging, Darmstadt (Germany); Kafchitsas, Konstantinos [Spine Center, Asklepios Klinik Lindenlohe, Schwandorf (Germany)

    2015-06-01

    To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. Average pedicle screw vector BMD (R1, 0.232 g/cm{sup 3}; R2, 0.166 g/cm{sup 3}; R3, 0.173 g/cm{sup 3}; global, 0.236 g/cm{sup 3}) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. (orig.)

  1. [Evaluation of the risk of mediastinal or retroperitoneal injuries caused by dorso-lumbar pedicle screws].

    Science.gov (United States)

    Hernigou, P; Germany, W

    1998-09-01

    Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of

  2. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  3. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    Science.gov (United States)

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each

  4. Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support.

    Science.gov (United States)

    Perez-Orribo, Luis; Kalb, Samuel; Reyes, Phillip M; Chang, Steve W; Crawford, Neil R

    2013-04-15

    Seven different combinations of posterior screw fixation, with or without interbody support, were compared in vitro using nondestructive flexibility tests. To study the biomechanical behavior of a new cortical screw (CS) fixation construct relative to the traditional pedicle screw (PS) construct. The CS is an alternative to the PS for posterior fixation of the lumbar spine. The CS trajectory is more sagittally and cranially oriented than the PS, being anchored in the pars interarticularis. Like PS fixation, CS fixation uses interconnecting rods fastened with top-locking connectors. Stability after bilateral CS fixation was compared with stability after bilateral PS fixation in the setting of intact disc and with direct lateral interbody fixation (DLIF) or transforaminal lateral interbody fixation (TLIF) support. Standard nondestructive flexibility tests were performed in cadaveric lumbar specimens, allowing non-paired comparisons of specific conditions from 28 specimens (4 groups of 7) within a larger experiment of multiple hardware configurations. Condition tested and group from which results originated were as follows: (1) intact (all groups); (2) with L3-L4 bilateral PS-rods (group 1); (3) with bilateral CS-rods (group 2); (4) with DLIF (group 3); (5) with DLIF + CS-rods (group 4); (6) with DLIF + PS-rods (group 3); (7) with TLIF + CS-rods (group 2), and (8) with TLIF + PS-rods (group 2). To assess spinal stability, the mean range of motion, lax zone, and stiff zone at L3-L4 were compared during flexion-extension, lateral bending, and axial rotation. With intact disc, stability was equivalent after PS-rod and CS-rod fixation, except that PS-rod fixation was stiffer during axial rotation. With DLIF support, there was no significant difference in stability between PS-rod and CS-rod fixation. With TLIF support, PS-rod fixation was stiffer than CS-rod fixation during lateral bending. Bilateral CS-rod fixation provided about the same stability in cadaveric specimens

  5. [The shor-term clinical outcomes and safety of extreme lateral interbody fusion combined with percutaneous pedicle screw fixation for the treatment of degenerative lumbar disease].

    Science.gov (United States)

    Hu, Xu-Dong; Ma, Wei-Hu; Jiang, Wei-Yu; Ruan, Chao-Yue; Chen, Yun-Lin

    2017-02-25

    To evaluate the early efficacy and safety of extreme lateral interbody fusion (XLIF) combined with percutaneous pedicle screw fixation for lumbar degenerative disease. From January 2013 to June 2014, 13 patients with degenerative lumbar disease were treated with XLIF combined with percutaneous pedicle screw fixation, including 8 cases of lumbar instability, 5 cases of mild to moderate lumbar spondylolisthesis;there were 5 males and 8 females, aged from 56 to 73 years with an average of 62.1 years. All patients were single segment fusion. Operation time, perioperative bleeding and perioperative complications were recorded. Visual analogue scale (VAS) and Oswestry Disability Index (ODI) were used to evaluate the clinical efficacy. Interbody fusion rate was observed and the intervertebral foramen area changes were compared preoperation and postoperation by X-rays and CT scanning. The mean operation time and perioperative bleeding in the patients respectively was(62.8±5.2) min and(82.5±22.6) ml. One case occurred in the numbness of femoribus internus and 1 case occurred in the muscle weakness of hip flexion after operation, both of them recovered within 2 weeks. All the patients were followed up from 12 to 19 months with an average of 15.6 months. VAS was decreased from preoperative 7.31±0.75 to 2.31±0.75 at final follow-up( P degenerative disease.

  6. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard A total of 48 patients (median age 49 years, range 21-81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CT scans were determined to be false negatives if surgery was still required and loosening of material was found. The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12-192 months). Median follow-up was 18 months (range 6-57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients. Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac

  7. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation

  8. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  9. Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique.

    Science.gov (United States)

    Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso

    2018-06-14

    This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both popen and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.

  10. History of Retractor Technologies for Percutaneous Pedicle Screw Fixation Systems.

    Science.gov (United States)

    Mobbs, Ralph J; Phan, Kevin

    2016-02-01

    Minimally invasive techniques aimed at minimizing surgery-associated risk and morbidity of spinal surgery have increased in popularity in recent years. Their potential advantages include reduced length of hospital stay, blood loss, and requirement for post-operative analgesia and earlier return to work. One such minimally invasive technique is the use of percutaneous pedicle screw fixation, which is paramount for promoting rigid and stable constructs and fusion in the context of trauma, tumors, deformity and degenerative disease. Percutaneous pedicle screw insertion can be an intimidating prospect for surgeons who have only been trained in open techniques. One of the ongoing challenges of this percutaneous system is to provide the surgeon with adequate access to the pedicle entry anatomy and adequate tactile or visual feedback concerning the position and anatomy of the rod and set-screw construct. This review article discusses the history and evolution of percutaneous pedicle screw retractor technologies and outlines the advances over the last decade in the rapidly expanding field of minimal access surgery for posterior pedicle screw based spinal stabilization. As indications for percutaneous pedicle screw techniques expand, the nuances of the minimally invasive surgery techniques and associated technologies will also multiply. It is important that experienced surgeons have access to tools that can improve access with a greater degree of ease, simplicity and safety. We here discuss the technical challenges of percutaneous pedicle screw retractor technologies and a variety of systems with a focus on the pros and cons of various retractor systems. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  11. Radiofrequency-activated PMMA-augmentation through cannulated pedicle screws: A cadaver study to determine the biomechanical benefits in the osteoporotic spine.

    Science.gov (United States)

    Karius, T; Deborre, C; Wirtz, D C; Burger, C; Prescher, A; Fölsch, A; Kabir, K; Pflugmacher, R; Goost, H

    2017-01-01

    PMMA-augmentation of pedicle screws strengthens the bone-screw-interface reducing cut-out risk. Injection of fluid cement bears a higher risk of extravasation, with difficulty of application because of inconsistent viscosity and limited injection time. To test a new method of cement augmentation of pedicle screws using radiofrequency-activated PMMA, which is suspected to be easier to apply and have less extravasations. Twenty-seven fresh-frozen human cadaver lumbar spines were divided into 18 osteoporotic (BMD ≤ 0.8 g/cm2) and 9 non-osteoporotic (BMD > 0.8 g/cm2) vertebral bodies. Bipedicular cannulated pedicle screws were implanted into the vertebral bodies; right screws were augmented with ultra-high viscosity PMMA, whereas un-cemented left pedicle screws served as negative controls. Cement distribution was controlled with fluoroscopy and CT scans. Axial pullout forces of the screws were measured with a material testing machine, and results were analyzed statistically. Fluoroscopy and CT scans showed that in all cases an adequately big cement depot with homogenous form and no signs of extravasation was injected. Pullout forces showed significant differences (p < 0.001) between the augmented and non-augmented pedicle screws for bone densities below 0.8 g/cm2 (661.9 N ± 439) and over 0.8 g/cm2 (744.9 N ± 415). Pullout-forces were significantly increased in osteoporotic as well as in non-osteoporotic vertebral bodies without a significant difference between these groups using this standardized, simple procedure with increased control and less complications like extravasation.

  12. Are We Underestimating the Significance of Pedicle Screw Misplacement?

    Science.gov (United States)

    Sarwahi, Vishal; Wendolowski, Stephen F; Gecelter, Rachel C; Amaral, Terry; Lo, Yungtai; Wollowick, Adam L; Thornhill, Beverly

    2016-05-01

    A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and

  13. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography

    Directory of Open Access Journals (Sweden)

    Bruno Moreira Gavassi

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS.METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient. No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4% while in the sagittal plane, 226 screws were found in ideal position (80.4%. Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281 of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.

  14. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?

    Science.gov (United States)

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2013-11-01

    Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright

  15. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  16. Clinical evaluation of patients undergoing dynamic pedicle fixation in lumbar spine

    Directory of Open Access Journals (Sweden)

    Felipe José Vieira Figueiredo

    2015-06-01

    Full Text Available OBJECTIVE: To evaluate the preliminary clinical results and complications in patients undergoing dynamic pedicle fixation of the spine in the treatment of a specific group of degenerative lumbar disease.METHODS: In this preliminary retrospective study, we selected 14 patients who underwent surgery from January 2006 to July 2010. We selected only patients with spondylolisthesis without spondylolysis (Grade 1 Meyerding. All patients underwent surgery at one level and the levels mostly addressed were: L3-L4, L4-L5 or L5-S1. The approach was the same in all patients (posterior median approach with preservation of the posterior elements. All patients underwent intense conservative treatment without clinical response and the same research algorithm preoperatively.RESULTS: Retrospective analysis of Oswestry questionnaire after selection and publication of results of 14 patients with Grade 1 spondylolisthesis who underwent dynamic pedicle stabilization in a total of 56 pedicle screws, being all in one level. There was no fracture of any screws, the mean hospital stay was a day and a half, no patient required blood transfusion and there were no cases of infection, with significant improvement in the Oswestry questionnaire.CONCLUSION: In this study, the dynamic pedicle stabilization method proved to be an excellent treatment option when surgical criteria are strictly adhered to. There was an improvement in Oswestry values, lower hospital stay and low rate of complications, consisting of an alternative in motion preservation surgery.

  17. Ball tip method for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis

    International Nuclear Information System (INIS)

    Watanabe, Kota; Matsumoto, Morio; Iizuka, Shingo

    2008-01-01

    The purpose of this study was to evaluate the efficacy of ball tip method for thoracic pedicle screw placements in idiopathic scoliosis patients. 24 patients with adolescent idiopathic scoliosis were included in this study. Conventional method was performed in 12 patients. Ball tip method was performed in 12 patients. Accuracy of the pedicle screw placement was evaluated based on the postoperative CT. In the ball tip method, a probe which was consisted of ball tip with flexible shaft was used. After removing of cortical bone at a starting point, the probe was inserted manually or sometimes with gently tapping by hammer. During the maneuver, the probe will gradually progress into cancellous bone in the pedicle, without perforating cortical bone in the pedicle. Following expansion of the hole by a rigid gear shift probe, screw was placed in the pedicle. 65.1% of screws were located within pedicle in the conventional group and 86.5% in the ball tip group. 5.3% of screws were located out of pedicle within 2 mm in the conventional group and 8.2% in the ball tip group. 15.8% of screws were located out of pedicle beyond 2 mm and 1.8% in the ball tip group. The ball tip method enhanced the accuracy of thoracic pedicle screw placements in adolescent idiopathic scoliosis patients. The ball tip method may be effective for accurate pedicle screw placement in patients with adolescent idiopathic scoliosis. (author)

  18. [Clinical research progress of direct surgical repair of lumbar spondylolysis in young patients].

    Science.gov (United States)

    Liu, Haichao; Qian, Jixian

    2013-01-01

    To review and summarize the surgical techniques and their outcomes for the treatment of lumbar spondylolysis in young patients by direct surgical repair. Both home and abroad literature on the surgical techniques and their outcomes respectively for the treatment of lumbar spondylolysis in young patients by direct surgical repair was reviewed extensively and summarized. Direct surgical repair of lumbar spondylolysis can offer a simple reduction and fixation for the injured vertebra, which is also in accord with normal anatomy and physiology. In this way, normal anatomy of vertebra can be sustained. As reported surgical techniques of direct repair, such as single lag screw, hook screw, cerclage wire, pedicle screw cable, pedicle screw rod, and pedicle screw hook system, they all can provide acceptable results for lumbar spondylolysis in young patients. Furthermore, to comply strictly with the inclusion criteria of surgical management and select the appropriate internal fixation can also contribute to a good effectiveness. Within the various methods of internal fixation, pedicle screw hook system has been widely recognized. Pedicle screw hook system fixation is simple and safe clinically. With the gradual improvement of this method and the development of minimally invasive technologies, it will have broad application prospects.

  19. In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application.

    Science.gov (United States)

    Liebsch, Christian; Zimmermann, Julia; Graf, Nicolas; Schilling, Christoph; Wilke, Hans-Joachim; Kienle, Annette

    2018-01-01

    Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0N shear force + 20.0N per step, 51.0N tension force + 10.2N per step, 4.2Nm bending moment + 0.8Nm per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMD 75.4 ± 4.0mg/cc HA, pedicle width 9.8 ± 0.6mm) were tested after implanting pedicle screws under X-ray control. Relative motions of pedicle screw, specimen fixture, and rod fixture were detected using an optical motion tracking system. Translational motions of the mechanical testing model experiments in the point of load introduction (0.9-2.2mm at 240N shear force) were reproducible within the variation range of the in vitro experiments (0.6-3.5mm at 240N shear force). Screw loosening occurred continuously in

  20. Effects of nonlinearity in the materials used for the semi-rigid pedicle screw systems on biomechanical behaviors of the lumbar spine after surgery

    International Nuclear Information System (INIS)

    Kim, Hyun; Lee, Sung-Jae; Lim, Do-Hyung; Oh, Hyun-Ju; Lee, Kwon-Yong

    2011-01-01

    Recently, various types of semi-rigid pedicle screw fixation systems have been developed for the surgical treatment of the lumbar spine. They were introduced to address the adverse issues commonly found in traditional rigid spinal fusion--abnormally large motion at the adjacent level and subsequent degeneration. The semi-rigid system uses more compliant materials (nitinol or polymers) and/or changes in rod design (coiled or twisted rods) as compared to the conventional rigid straight rods made of Ti alloys (E = 114 GPa, υ = 0.32). However, biomechanical studies on the semi-rigid pedicle screw systems were usually limited to linear modeling of the implant and anatomic elements, which may not be capable of reflecting realistic post-operative motions of the spine. In this study, we evaluated the effects of nonlinearity in materials used for semi-rigid pedicle screw fixation systems to evaluate the changes in biomechanical behaviors using finite element analysis. Changes in range of motion (ROM) and center of rotation (COR) were assessed at the operated and adjacent levels. Actual load-displacement results of the semi-rigid rod from mechanical test were carried out to reflect the nonlinearity of the implant. In addition, nonlinear material properties of various spinal ligaments studies were used for the finite element modeling. The post-operative models were constructed by modifying the previously validated intact model of the L1-S1 spine. Eight different post-operative models were made to address the effects of nonlinearity-with a traditional stiffness modulus rod (with linear ligaments, case 1; with nonlinear ligaments, case 5), with a rigid rod (with linear ligaments, case 2; with nonlinear ligaments, case 6), with a soft rod (with linear ligaments, case 3; with nonlinear ligaments, case 7), and with a nonlinear rod (with linear ligaments, case 4; with nonlinear ligaments, case 8). To simulate the load on the lumbar spine in a neutral posture, follower load (400 N

  1. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.

    Directory of Open Access Journals (Sweden)

    Fei Guo

    Full Text Available Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine.Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis. The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group, pedicle screws fixation were guided by the navigation template; in the second set (Control group, the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is 1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable.A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group.The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.

  2. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.

    Science.gov (United States)

    Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi

    2017-01-01

    Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. The individualized 3D printing navigation template for pedicle screw fixation is easy and safe

  3. Simple Technique for Removing Broken Pedicular Screws

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2014-03-01

    Full Text Available The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to current admission and had developed the complication of pedicle screw breakage within the vertebral body. The patient underwent re-exploration and removal of the distal screws. Through a paravertebral incision and muscle separation, the screws and rods were exposed and the implants were removed.

  4. Intra-operative computer navigation guided cervical pedicle screw insertion in thirty-three complex cervical spine deformities

    Directory of Open Access Journals (Sweden)

    S Rajasekaran

    2010-01-01

    Full Text Available Background: Cervical pedicle screw fixation is challenging due to the small osseous morphometrics and the close proximity of neurovascular elements. Computer navigation has been reported to improve the accuracy of pedicle screw placement. There are very few studies assessing its efficacy in the presence of deformity. Also cervical pedicle screw insertion in children has not been described before. We evaluated the safety and accuracy of Iso-C 3D-navigated pedicle screws in the deformed cervical spine. Materials and Methods: Thirty-three patients including 15 children formed the study group. One hundred and forty-five cervical pedicle screws were inserted using Iso-C 3D-based computer navigation in patients undergoing cervical spine stabilization for craniovertebral junction anomalies, cervico-thoracic deformities and cervical instabilities due to trauma, post-surgery and degenerative disorders. The accuracy and containment of screw placement was assessed from postoperative computerized tomography scans. Results: One hundred and thirty (89.7% screws were well contained inside the pedicles. Nine (6.1% Type A and six (4.2% Type B pedicle breaches were observed. In 136 levels, the screws were inserted in the classical description of pedicle screw application and in nine deformed vertebra, the screws were inserted in a non-classical fashion, taking purchase of the best bone stock. None of them had a critical breach. No patient had any neurovascular complications. Conclusion: Iso-C navigation improves the safety and accuracy of pedicle screw insertion and is not only successful in achieving secure pedicle fixation but also in identifying the best available bone stock for three-column bone fixation in altered anatomy. The advantages conferred by cervical pedicle screws can be extended to the pediatric population also.

  5. Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion

    International Nuclear Information System (INIS)

    Sugimoto, Yoshihisa; Ito, Yasuo; Shimokawa, Tetsuya; Shiozaki, Yasuyuki; Mazaki, Tetsuro; Tomioka, Masao; Tanaka, Masato

    2010-01-01

    Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 vertebrae (C7 to T6) in 38 patients. Screws were placed using intraoperative data acquisition by an isocentric C-arm fluoroscope (Siremobile Iso-C3D) and computer navigation. Out of 90 pedicle screws inserted into 45 vertebrae between C7 and T2, 87 of the 90 (96.7%) screws were classified as grade 1 (no perforation). Of 64 pedicle screws inserted into 33 vertebrae between T3 and T6, 61 of 64 (95.3%) screws were classified as grade 1. In this study, we reduced pedicle screw misplacement at the level of the C7 and upper thoracic (T1-6) vertebrae using the three-dimensional fluoroscopy navigation system. (author)

  6. Accuracy of navigated pedicle screw insertion by a junior spine surgeon without spinal surgery experience

    International Nuclear Information System (INIS)

    Yamazaki, Hironori; Kotani, Toshiaki; Motegi, Hiroyuki; Nemoto, Tetsuharu; Koshi, Takana; Nagahara, Ken; Minami, Syohei

    2010-01-01

    The purpose of this study was to investigate pedicle screw placement accuracy during navigated surgery by a junior spine surgeon who had no spinal surgery experience. A junior spine surgeon with no spinal surgery experience implanted a total of 137 pedicle screws by using a navigation system. Postoperative computerized tomography was performed to evaluate screw placement, and the pedicle perforation rate was 2.2%. There were no neurologic or vascular complications related to the pedicle screws. The results demonstrated that pedicle screws can be placed safely and effectively by a junior spine surgeon who has no spinal surgery experience when instructed by a senior spine surgeon. The results of this study suggest that navigation can be used as a surgical training tool for junior spine surgeons. (author)

  7. Therapeutic efficacy of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting for tuberculosis of lumbar vertebra

    Directory of Open Access Journals (Sweden)

    Jia-ming LIU

    2015-11-01

    Full Text Available Objective To evaluate the efficacy and safety of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting in the treatment of tuberculosis of mono-segmental lumbar vertebra. Methods From January 2010 to April 2013, 21 patients (9 males and 12 females with an average age of 49.1 years with mono-segmental tuberculosis of lumbar vertebra underwent surgery in our hospital were included. Eight patients had neurological deficit. The focus of tuberculosis was located on one side of the vertebral body, and all the patients had obvious signs of bone destruction on CT and MRI. All the patients were given anti-tuberculosis chemotherapy for 2-3 weeks before surgery. The local bone chips and autologous iliac cancellous bone were used as the intervertebral bone graft. Postoperative plain radiographs and CT were obtained to evaluate the fusion rate and degree of lumbar lordosis. The visual analogue scale score (VAS, erythrocyte sedimentation rate (ESR, and C-reactive protein (CRP before and after operation, and at final follow-up date were recorded. Results All the patients were followed up for 25.3±4.2 months. The mean operation time was 157±39 minutes, and the average blood loss was 470±143ml. The fusion rate of the interbody bone graft was 95.2%, with an average fusion period of 6.1±2.5 months. The neurological function was improved by 100%, and no severe complication or neurological injury occured. The preoperative and postoperative lordosis angles of the lumbar spine were 21.4°±5.7° and 33.6°±3.1°, respectively, and it was 31.3°±2.7° at the final follow up. The preoperative and postoperative VAS scores were 7.8±2.6 and 2.4±1.7 respectively, and it was 0.9±0.7 at the final follow up. The ESR and CRP were significantly decreased 3 months after surgery, and they became normal at 6 months. Conclusion Pedicle screw-rod internal fixation after one-stage posterior

  8. Creation of false pedicles and a neo-pelvis for lumbopelvic reconstruction following en bloc resection of an iliosacral chondrosarcoma with lumbar spine extension: technical note.

    Science.gov (United States)

    Mendel, Ehud; Nathoo, Narendra; Scharschmidt, Thomas; Schmidt, Carl; Boehmler, James; Mayerson, Joel L

    2014-03-01

    En bloc resection with negative tumor margins remains the principal treatment option for control or cure of primary pelvic chondrosarcomas, as current adjuvant therapies remain ineffective. Iliosacral chondrosarcomas with involvement of the sciatic notch are sufficiently challenging tumors. However, when there is concomitant lumbar extension requiring resection of the pedicles to maintain negative surgical margins, transpedicular screw fixation is not possible, making reconstruction of the lumbopelvic junction extremely challenging. A patient with an iliosacral chondrosarcoma with lumbar spine extension is presented in this report to illustrate a novel lumbopelvic spinal construct. Following combined external pelvectomy and hemisacrectomy with contralateral L3-5 hemilaminectomy and ipsilateral pediculotomy, bicortical transvertebral body screws were substituted for the missing pedicles, resulting in the creation of "false pedicles," which were further supplemented with an autologous vascularized fibular strut graft from the amputated lower limb and applied to the lateral aspect of the vertebral bodies. The creation of false pedicles allowed for a robust reconstruction of the lumbopelvic junction, including maintaining pelvic ring integrity with a "neo-pelvis", creating a functional load-bearing construct adequate for early mobilization and ambulation. The biomechanical dynamics of this unique construct are also discussed.

  9. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    Science.gov (United States)

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be

  10. CT provides precise size assessment of implanted titanium alloy pedicle screws.

    Science.gov (United States)

    Elliott, Michael J; Slakey, Joseph B

    2014-05-01

    After performing instrumented spinal fusion with pedicle screws, postoperative imaging using CT to assess screw position may be necessary. Stainless steel implants produce significant metal artifact on CT, and the degree of distortion is at least partially dependent on the cross-sectional area of the implanted device. If the same effect occurs with titanium alloy implants, ability to precisely measure proximity of screws to adjacent structures may be adversely affected as screw size increases. We therefore asked whether (1) CT provides precise measurements of true screw widths; and (2) precision degrades based on the size of the titanium implant imaged. CT scans performed on 20 patients after instrumented spinal fusion for scoliosis were reviewed. The sizes of 151 titanium alloy pedicle screws were measured and compared with known screw size. The amount of metal bloom artifact was determined for each of the four screw sizes. ANOVA with Tukey's post hoc test were performed to evaluate differences in scatter, and Spearman's rho coefficient was used to measure relationship between screw size and scatter. All screws measured larger than their known size, but even with larger 7-mm screws the size differential was less than 1 mm. The four different screw sizes produced scatter amounts that were different from each other (p titanium alloy pedicle screws produces minimal artifact, thus making this the preferred imaging modality to assess screw position after surgery. Although the amount of artifact increases with the volume of titanium present, the degree of distortion is minimal and is usually less than 1 mm.

  11. Anatomical study of lumbar vertebral pedicle and adjacent neural structures

    Directory of Open Access Journals (Sweden)

    Matuoka Cláudia Maria

    2002-01-01

    Full Text Available For the evaluation of the Lumbar pedicle morphometry and its relation to the neural structures, 14 male adult cadavers were dissected, and the size of the lumbar pedicle was assessed by measuring its sagittal and transversal diameter. It was found that the size of the pedicle increases from L2 to L5, both in the sagittal and transversal diameter, the first bigger. The relation of the lumbar pedicle to the neural structures was evaluated by measuring the distance between dura-mater and the pedicle medial area, the distance between the most distal area of the pedicle and the nerve root that appears under it, and , to obtain in an indirect way, the distance between the pedicle apex and the nerve root that appears over it. The acquired results showed that the distance between the most distal area of the pedicle and the nerve root that appears under it, and the distance between the pedicle medial area and dura-mater, do not increase from L2 to L5, and they are in average 1,98 and 3,02 respectively. The distance between the pedicle apex and the nerve root that appears over it, increases from L2 to L5, varying from 13,64 in L2 to 21,62 in L5. The location of the spinal ganglion in relation to the pedicle has also been found, and 87% of the spinal ganglions are located in the foraminal zone.

  12. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  13. Adolescent idiopathic scoliosis: sagital plane and low density pedicle screws

    Directory of Open Access Journals (Sweden)

    Rodrigo Augusto do Amaral

    2014-03-01

    Full Text Available OBJECTIVE: To examine the sagittal curves of patients treated with CD instrumentation using exclusively pedicle screws. METHODS: Image analysis of medical records of 27 patients (26 M and 1 F with a minimum follow-up of 6 months, who underwent surgical treatment in our service between January 2005 and December 2010. The curves were evaluated on coronal and sagittal planes, taking into account the potential correction of the technique. RESULTS: In the coronal plan the following curves were evaluated: proximal thoracic (TPx, main thoracic (TPp, and thoracolumbar; lumbar (TL, L, and the average flexibility was 52%, 52%, and 92% and the capacity of correction was 51%, 72%, and 64%, respectively. In the sagittal plane there was a mean increase in thoracic kyphosis (CT of 41% and an average reduction of lumbar lordosis (LL of 17%. Correlation analysis between variables showed Pearson coefficient of correlation of 0.053 and analysis of dispersion of R2 = <0.001. CONCLUSION: The method has shown satisfactory results with maintenance of kyphosis correction in patients with normal and hyper kyphotic deformities.

  14. Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique

    International Nuclear Information System (INIS)

    He Xishun; Yang Huilin; Zhu Ruofu; Tan Xiangqi; Wang Genlin; Tang Tiansi

    2008-01-01

    Objective: To explore a safe and effective method for placing the cervical pedicle screws. Methods: There were ten adult cadaver specimens of cervica spine (C 1 -C 7 ) with intact structures including ligament and perivertebral muscles. The spiral computed tomography scan (Elscint CT Twin flash) at the section of 1 mm and three-dimensional reconstruction of all 10 cervical specimens were taken. By CT scan, the parameters of the cervical pedicles were measure,Then taking randomly 5 cervical specimens, according to the CT measurements, an appropriate screw was inserted into pedicle individually. In the other 5 human cadaver cervical vertebraes, Φ3.5 mm screws were inserted into the C 2 -C 7 pedicles by assisted by CT-based navigation system. Cortical integrity of every sample was examined by anatomic dissection, the spiral computed tomography scan and arrows,and coronal reconstruction. Results: Sixty screws was inserted into pedicle individually, and the achievement ratio was 90%, the perfectness ratio was 75%, 60 screws was placed into pedicle assisted by CT-based navigation system, and the achievement ratio was 96.6%, the perfectness ratio was 90%. By chi-square test for statistical analysis, there were no statistical significance between the accuracy rate of two methods(P>0.05). However there was statistical significance between the perfectness ratio between two methods(P<0.05). Conclusion: Compared with the individual cervical peddle screws placement technique, the perfectness ratio of pedicle screw fixation of cervical spine assisted by CT-based navigation system is higher, but there are no significant difference in accuracy. (authors)

  15. A Novel Pedicle Screw with Mobile Connection: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Yasuaki Tokuhashi

    2014-01-01

    Full Text Available To prevent adjacent disc problems after spinal fusion, a pedicle screw with a mobile junction between the head and threaded shaft was newly developed. The threaded shaft of the screw has 10 degrees mobility in all directions, but its structure is to prevent abnormal translation and tilting. This screw was evaluated as follows: (1 endurance test: 106 times rotational stress was applied; (2 biological reactions: novel screws with a mobile head and conventional screws with a fixed head were inserted into the bilateral pedicles of the L3, L4, and L5 in two mini pigs with combination. Eight months after surgery, vertebral units with the screw rod constructs were collected. After CT scan, the soft and bony tissues around the screws were examined grossly and histologically. As a result, none of the screws broke during the endurance test stressing. The mean amount of abrasion wear was 0.0338 g. In the resected mini pig section, though zygapophyseal joints between fixed-head screws showed bony union, the amount of callus in the zygapophyseal joints connected with mobile-head screws was small, and joint space was confirmed by CT. No metalloses were noted around any of the screws. Novel screws were suggested to be highly durable and histologically safe.

  16. Application of an expandable pedicle screw in the severe osteoporotic spine: a preliminary study.

    Science.gov (United States)

    Wu, Zi-xiang; Cui, Geng; Lei, Wei; Fan, Yong; Wan, Shi-yong; Ma, Zhen-sheng; Sang, Hong-xun

    2010-12-01

    To investigate the clinical abstract and radiographic outcome of multi-axial expandable pedicle screws (MEPS) in patients with osteoporosis. One hundred and twenty-five consecutive patients received MEPS from the UPASS spinal fixation system to obtain thoracolumbar or lumbosacral stabilization. All patients underwent bone mineral density (BMD) scans. The indications for use of the MEPS were spinal diseases with severe osteoporosis (degenerative diseases 46 cases, compression fractures 28 cases, lumbar tuberculosis 27 cases and revision spine surgery 24 cases). The pre-operative and three months post-operative functional evaluations were graded with JOA and VAS scoring system. One week, six months and 12 months after surgery, plain film and three-dimensional CT scans were obtained to evaluate the spinal fusion and fixation effectiveness of MEPS. The mean follow-up period was 18 months (ranged from 6 to 33 months). All patients suffered from severely osteoporosis with a decrease of 25.3% in BMD. The pre-operative JOA and VAS scores were 11.3±3.0 and 6.7±1.8 mm, respectively. Three months after operation, the JOA and VAS scores were 25.2±2.0 and 2.3±1.7 mm. The recovery rate was 78.1±11.5% and the clinical results were satisfying. There were no instances of screw loosening or pullout of the MEPS and the screw-bone interface was excellent. The radiographic results showed that bone healing, both around the screws and inter-vertebral, was achieved. In osteoporosis spine surgery, excellent bone-screw interface and fixation strength can be achieved by using MEPS. MEPS are a novel approach to increase the pedicle screw fixation in osteoporotic and revision spine surgeries.

  17. A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases

    Science.gov (United States)

    Chen, Xiong-sheng; Zhou, Sheng-yuan; Jia, Lian-shun; Gu, Xiao-min; Fang, Lei; Zhu, Wei

    2013-01-01

    Objective To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis. Methods Twenty-four patients with isthmic spondylolysis at L5 and grade 0–I spondylolisthesis (Meyerding classification) received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS) and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed. Results Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (Pspondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis. PMID:23691090

  18. A universal pedicle screw and V-rod system for lumbar isthmic spondylolysis: a retrospective analysis of 21 cases.

    Directory of Open Access Journals (Sweden)

    Xiong-sheng Chen

    Full Text Available To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis.Twenty-four patients with isthmic spondylolysis at L5 and grade 0-I spondylolisthesis (Meyerding classification received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed.Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (P<0.001. The VAS scores were 0 to 3 at 6 months postoperatively in all patients and no back pain was reported in all patients except 2 patients who complained of back pain after prolonged sitting. X-ray examination showed a bone graft healing time of 3 to 12 months. Grade I spondylolisthesis improved to grade 0 in 4 patients and no noticeable change was observed in the remaining 17 cases. The intervertebral space height at L5/S1 was statistically increased (P<0.05 while no statistically significant change was seen at L4/L5. There was no statistically significant difference in the ROM of the intervertebral disks of L5/S1 and L4/5 before and after surgery.The universal pedicle screw-V rod system and isthmic bone grafting directly repairs isthmic spondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis.

  19. Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection

    Directory of Open Access Journals (Sweden)

    Engin Çetin

    2015-01-01

    Full Text Available Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod. In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01. Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005. Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

  20. Two-level anterior lumbar interbody fusion with percutaneous pedicle screw fixation. A minimum 3-year follow-up study

    International Nuclear Information System (INIS)

    Lee, Dong-Yeob; Lee, Sang-Ho; Maeng, Dae-Hyeon

    2010-01-01

    The clinical and radiological outcomes of two-level anterior lumbar interbody fusion (ALIF) with percutaneous pedicle screw fixation (PSF) were evaluated in 24 consecutive patients who underwent two level ALIF with percutaneous PSF for segmental instability and were followed up for more than 3 years. Clinical outcomes were assessed using a visual analogue scale (VAS) score and the Oswestry Disability Index (ODI). Sagittal alignment, bone union, and adjacent segment degeneration (ASD) were assessed using radiography and magnetic resonance imaging. The mean age of the patients at the time of operation was 56.3 years (range 39-70 years). Minor complications occurred in 2 patients in the perioperative period. At a mean follow-up duration of 39.4 months (range 36-42 months), VAS scores for back pain and leg pain, and ODI score decreased significantly (from 6.5, 6.8, and 46.9% to 3.0, 1.9, and 16.3%, respectively). Clinical success was achieved in 22 of the 24 patients. The mean segmental lordosis, whole lumbar lordosis, and sacral tilt significantly increased after surgery (from 25.1deg, 39.2deg, and 32.6deg to 32.9deg, 44.5deg, and 36.6deg, respectively). Solid fusion was achieved in 21 patients. ASD was found in 8 of the 24 patients. No patient underwent revision surgery due to nonunion or ASD. Two-level ALIF with percutaneous PSF yielded satisfactory clinical and radiological outcomes and could be a useful alternative to posterior fusion surgery. (author)

  1. Two-level anterior lumbar interbody fusion with percutaneous pedicle screw fixation. A minimum 3-year follow-up study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Yeob; Lee, Sang-Ho; Maeng, Dae-Hyeon [Wooridul Spine Hospital, Seoul (Korea, Republic of)

    2010-08-15

    The clinical and radiological outcomes of two-level anterior lumbar interbody fusion (ALIF) with percutaneous pedicle screw fixation (PSF) were evaluated in 24 consecutive patients who underwent two level ALIF with percutaneous PSF for segmental instability and were followed up for more than 3 years. Clinical outcomes were assessed using a visual analogue scale (VAS) score and the Oswestry Disability Index (ODI). Sagittal alignment, bone union, and adjacent segment degeneration (ASD) were assessed using radiography and magnetic resonance imaging. The mean age of the patients at the time of operation was 56.3 years (range 39-70 years). Minor complications occurred in 2 patients in the perioperative period. At a mean follow-up duration of 39.4 months (range 36-42 months), VAS scores for back pain and leg pain, and ODI score decreased significantly (from 6.5, 6.8, and 46.9% to 3.0, 1.9, and 16.3%, respectively). Clinical success was achieved in 22 of the 24 patients. The mean segmental lordosis, whole lumbar lordosis, and sacral tilt significantly increased after surgery (from 25.1deg, 39.2deg, and 32.6deg to 32.9deg, 44.5deg, and 36.6deg, respectively). Solid fusion was achieved in 21 patients. ASD was found in 8 of the 24 patients. No patient underwent revision surgery due to nonunion or ASD. Two-level ALIF with percutaneous PSF yielded satisfactory clinical and radiological outcomes and could be a useful alternative to posterior fusion surgery. (author)

  2. Clinical results of free-hand pedicle screw placement by the palpation of lateral wall of pedicle (PLP) method for scoliosis surgery

    International Nuclear Information System (INIS)

    Oyama, Motohiko; Shimizu, Takachika; Fueki, Keisuke; Ino, Masatake; Toda, Naofumi; Tanouti, Tetu; Tatara, Yasunori; Manabe, Nodoka

    2011-01-01

    The purpose of this study was to evaluate the accuracy of thoracic pedicle screw (TPS) placement by the palpation of the lateral wall of the pedicle (PLP) method. The subjects of this study were 45 scoliosis patients. The accuracy of TPS placement was evaluated by postoperative CT. Of the 348 TPSs inserted, 26 (7.5%) breached the pedicle wall. Of the 26 misplaced screws, 20 were inserted on the wrong trajectory, and 6 were inserted at the wrong insertion point. The preoperative major Cobb angle averaged 70.4 deg in the group with pedicle perforation by the TPS, and 54.1 deg in the group with correct placement of the TPS (p=0.006). No intra- or post-operative complications developed as a result of the pedicle perforation. The PLP method is useful in deciding on the correct insertion point, but it is of no assistance in inserting screws along the correct trajectory. This, it will be necessary to improve the technique of determining the correct trajectory for the TPS. (author)

  3. Virtual surgery simulation versus traditional approaches in training of residents in cervical pedicle screw placement.

    Science.gov (United States)

    Hou, Yang; Shi, Jiangang; Lin, Yanping; Chen, Huajiang; Yuan, Wen

    2018-06-01

    The cervical screw placement is one of the most difficult procedures in spine surgery, which often needs a long period of repeated practices and could cause screw placement-related complications. We performed this cadaver study to investigate the effectiveness of virtual surgical training system (VSTS) on cervical pedicle screw instrumentation for residents. A total of ten novice residents were randomly assigned to two groups: the simulation training (ST) group (n = 5) and control group (n = 5). The ST group received a surgical training of cervical pedicle screw placement on VSTS and the control group was given an introductory teaching session before cadaver test. Ten fresh adult spine specimens including 6 males and 4 females were collected, and were randomly allocated to the two groups. The bilateral C3-C6 pedicle screw instrumentation was performed in the specimens of the two groups, respectively. After instrumentation, screw positions of the two groups were evaluated by image examinations. There was significantly statistical difference in screw penetration rates between the ST (10%) and control group (62.5%, P VSTS as an advanced training tool exhibited promising effects on improving performance of novice residents in cervical pedicle screw placement compared with the traditional teaching methods.

  4. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of

  5. Robot assisted navigated drilling for percutaneous pedicle screw placement: A preliminary animal study

    Directory of Open Access Journals (Sweden)

    Hongwei Wang

    2015-01-01

    Conclusions: The preliminary study supports the view that computer assisted pedicle screw fixation using spinal robot is feasible and the robot can decrease the intraoperative fluoroscopy time during the minimally invasive pedicle screw fixation surgery. As spine robotic surgery is still in its infancy, further research in this field is worthwhile especially the accuracy of spine robot system should be improved.

  6. Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report.

    Science.gov (United States)

    Watanabe, Kei; Yamazaki, Akiyoshi; Hirano, Toru; Izumi, Tomohiro; Sano, Atsuki; Morita, Osamu; Kikuchi, Ren; Ito, Takui

    2010-09-15

    Case report. To describe an iatrogenic aortic injury by pedicle screw instrumentation during posterior reconstructive surgery of spinal deformity. Iatrogenic major vascular injuries during anterior instrumentation procedures have been reported by several authors, but there have been few reports regarding iatrogenic major vascular injuries during posterior instrumentation procedures. A 57-year-old woman with thoracolumbar kyphosis due to osteoporotic T12 vertebral fracture underwent posterior correction and fusion (T10-L2), using segmental pedicle screw construct concomitant with T12 pedicle subtraction osteotomy. Postoperative routine plain radiographs and computed tomography myelography demonstrated a misplaced left T10 pedicle screw, which was in contact with the posteromedial aspect of the thoracic aorta, and suspected penetration of the aortic wall. The patient underwent removal of the pedicle screw, and repair of the penetrated aortic wall through a simultaneous anterior-posterior approach. The patient tolerated the procedure well without neurologic sequelae, and was discharged several days after removal of a left tube thoracostomy. Plain radiographs demonstrated solid fusion at the osteotomy site and no loosening of hardware. Preoperative neurologic symptoms improved completely at 18-months follow-up. Use of pedicle screw instrumentation has the potential to cause major vascular injury during posterior spinal surgery, and measures to prevent this complication must be taken. Timely diagnosis and treatment are essential to prevent both early and delayed complications and death.

  7. Minimally Invasive Transforaminal Lumbar Interbody Fusion with Percutaneous Bilateral Pedicle Screw Fixation for Lumbosacral Spine Degenerative Diseases. A retrospective database of 40 consecutive treated cases and literature review.

    Science.gov (United States)

    Millimaggi, Daniele Francesco; DI Norcia, Valerio; Luzzi, Sabino; Alfiero, Tommaso; Galzio, Renato Juan; Ricci, Alessandro

    2017-04-12

    To report our results about minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) with bilateral pedicle screw fixation, in patients with degenerative lumbosacral spine disease. To describe the indications, surgical technique and results of a consecutive series of 40 patients undergone MI-TLIF. Despite the limited number of clinical studies, published data suggest tremendous potential advantages of this technique. Forty patients with radiological findings of degenerative lumbosacral spine disease were undergone MI-TLIF between July 2012 and January 2015. Clinical outcomes were assessed by means of Oswestry Disability Index (ODI) and Health Survey Scoring (SF36) before surgery and at first year follow-up. Furthermore, the following parameters were retrospectively reviewed: age, sex, working activity, body mass index (BMI), type of degenerative disease, number of levels of fusion, operative time, blood loss, length of hospital stay. Average operative time was of 230 minutes, mean estimated blood loss 170 mL, average length of hospital stay 5 days. The ODI improved from a score of 59, preoperatively, to post-operative score of 20 at first year follow-up. Average SF36 score increased from 36 to 54 (Physical Health) and from 29 to 50 (Mental Health) at first year outcome evaluation. MI-TLIF with bilateral pedicle screw fixation is an excellent choice for selected patients suffering from symptomatic degenerative lumbosacral spine disease, especially secondary to recurrent disk herniations.

  8. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  9. Alternative radiation-free registration technique for image-guided pedicle screw placement in deformed cervico-thoracic segments.

    Science.gov (United States)

    Kantelhardt, Sven R; Neulen, Axel; Keric, Naureen; Gutenberg, Angelika; Conrad, Jens; Giese, Alf

    2017-10-01

    Image-guided pedicle screw placement in the cervico-thoracic region is a commonly applied technique. In some patients with deformed cervico-thoracic segments, conventional or 3D fluoroscopy based registration of image-guidance might be difficult or impossible because of the anatomic/pathological conditions. Landmark based registration has been used as an alternative, mostly using separate registration of each vertebra. We here investigated a routine for landmark based registration of rigid spinal segments as single objects, using cranial image-guidance software. Landmark based registration of image-guidance was performed using cranial navigation software. After surgical exposure of the spinous processes, lamina and facet joints and fixation of a reference marker array, up to 26 predefined landmarks were acquired using a pointer. All pedicle screws were implanted using image guidance alone. Following image-guided screw placement all patients underwent postoperative CT scanning. Screw positions as well as intraoperative and clinical parameters were retrospectively analyzed. Thirteen patients received 73 pedicle screws at levels C6 to Th8. Registration of spinal segments, using the cranial image-guidance succeeded in all cases. Pedicle perforations were observed in 11.0%, severe perforations of >2 mm occurred in 5.4%. One patient developed a transient C8 syndrome and had to be revised for deviation of the C7 pedicle screw. No other pedicle screw-related complications were observed. In selected patients suffering from pathologies of the cervico-thoracic region, which impair intraoperative fluoroscopy or 3D C-arm imaging, landmark based registration of image-guidance using cranial software is a feasible, radiation-saving and a safe alternative.

  10. Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model.

    Science.gov (United States)

    Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat

    2018-02-01

    Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

  11. Pedicle screw-rod fixation: a feasible treatment for dogs with severe degenerative lumbosacral stenosis.

    Science.gov (United States)

    Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P

    2015-12-07

    Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.

  12. Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study.

    Science.gov (United States)

    Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen

    2018-03-14

    The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.

  13. 3D printing-assisted preoperative plan of pedicle screw placement for middle-upper thoracic trauma: a cohort study.

    Science.gov (United States)

    Xu, Wei; Zhang, Xuming; Ke, Tie; Cai, Hongru; Gao, Xiang

    2017-08-11

    This study aimed to evaluate the application of 3D printing in assisting preoperative plan of pedicle screw placement for treating middle-upper thoracic trauma. A preoperative plan was implemented in seven patients suffering from middle-upper thoracic (T3-T7) trauma between March 2013 and February 2016. In the 3D printing models, entry points of 56 pedicle screws (Magerl method) and 4 important parameters of the pedicle screws were measured, including optimal diameter (ϕ, mm), length (L, mm), inclined angle (α), head-tilting angle (+β), and tail-tilting angle (-β). In the surgery, bare-hands fixation of pedicle screws was performed using 3D printing models and the measured parameters as guidance. A total of seven patients were enrolled, including five men and two women, with the age of 21-62 years (mean age of 37.7 years). The position of the pedicle screw was evaluated postoperatively using a computerized tomography scan. Totally, 56 pedicle screws were placed, including 33 pieces of level 0, 18 pieces of level 1, 4 pieces of level 2 (pierced lateral wall), and 1 piece of level 3 (pierced lateral wall, no adverse consequences), with a fine rate of 91.0%. 3D printing technique is an intuitive and effective assistive technology to pedicle screw fixation for treating middle-upper thoracic vertebrae, which improve the accuracy of bare-hands screw placement and reduce empirical errors. The trial was approved by the Ethics Committee of the Fujian Provincial Hospital. It was registered on March 1st, 2013, and the registration number was K2013-03-001.

  14. The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients.

    Science.gov (United States)

    Zhang, Xin-Liang; Huang, Da-Geng; Wang, Xiao-Dong; Zhu, Jin-Wen; Li, Yi-Bing; He, Bao-Rong; Hao, Ding-Jun

    2017-04-01

    Ponticulus posticus is a common anatomic variation that can be mistaken for a broad posterior arch during C1 pedicle screw placement. When the atlas lateral mass screws are placed via the posterior arch, injury to the vertebral artery may result. To our knowledge, there are few clinical studies that have analyzed the feasibility of C1 pedicle screw fixation in patients with ponticulus posticus, in clinical practice. To evaluate the feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus. Between January 2008 and January 2012, 11 consecutive patients with atlantoaxial instability, and with a ponticulus posticus at C1, underwent posterior fusion surgery in our institution. According to preoperative computed tomography (CT) reconstruction, a complete ponticulus posticus was found unilaterally in nine patients and bilaterally in two. Postoperative CT reconstructive imaging was performed to assess whether C1 pedicle screw placement was successful. Patients were followed up at regular intervals and evaluated for symptoms of ponticulus posticus syndrome. Thirteen C1 pedicles (atlas vertebral artery groove), each with a complete ponticulus posticus, were successfully inserted with thirteen 3.5- or 4.0-mm diameter pedicle screws, without resection of the bony anomaly. No intraoperative complications (venous plexus, vertebral artery, or spinal cord injury) occurred. The mean follow-up period was 21 (range 14-30) months. Postoperative CT reconstructive images showed that all 13 pedicle screws were inserted in the C1 pedicles without destruction of the atlas pedicle cortical bone. In the follow-up period, none of the patients demonstrated clinical symptoms of ponticulus posticus syndrome or developed bone fusion. Three-dimensional CT imaging should be considered prior to C1 pedicle screw fixation in patients with ponticulus posticus, to avoid mistaking the ponticulus posticus for a widened dorsal arch of the atlas. If there is no ponticulus posticus

  15. Pullout characteristics of percutaneous pedicle screws with different cement augmentation methods in elderly spines: An in vitro biomechanical study.

    Science.gov (United States)

    Charles, Y P; Pelletier, H; Hydier, P; Schuller, S; Garnon, J; Sauleau, E A; Steib, J-P; Clavert, P

    2015-05-01

    Vertebroplasty prefilling or fenestrated pedicle screw augmentation can be used to enhance pullout resistance in elderly patients. It is not clear which method offers the most reliable fixation strength if axial pullout and a bending moment is applied. The purpose of this study is to validate a new in vitro model aimed to reproduce a cut out mechanism of lumbar pedicle screws, to compare fixation strength in elderly spines with different cement augmentation techniques and to analyze factors that might influence the failure pattern. Six human specimens (82-100 years) were instrumented percutaneously at L2, L3 and L4 by non-augmented screws, vertebroplasty augmentation and fenestrated screws. Cement distribution (2 ml PMMA) was analyzed on CT. Vertebral endplates and the rod were oriented at 45° to the horizontal plane. The vertebral body was held by resin in a cylinder, linked to an unconstrained pivot, on which traction (10 N/s) was applied until rupture. Load-displacement curves were compared to simultaneous video recordings. Median pullout forces were 488.5 N (195-500) for non-augmented screws, 643.5 N (270-1050) for vertebroplasty augmentation and 943.5 N (750-1084) for fenestrated screws. Cement augmentation through fenestrated screws led to significantly higher rupture forces compared to non-augmented screws (P=0.0039). The pullout force after vertebroplasty was variable and linked to cement distribution. A cement bolus around the distal screw tip led to pullout forces similar to non-augmented screws. A proximal cement bolus, as it was observed in fenestrated screws, led to higher pullout resistance. This cement distribution led to vertebral body fractures prior to screw pullout. The experimental setup tended to reproduce a pullout mechanism observed on radiographs, combining axial pullout and a bending moment. Cement augmentation with fenestrated screws increased pullout resistance significantly, whereas the fixation strength with the vertebroplasty

  16. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.

    Science.gov (United States)

    Luo, Jiaquan; Wu, Chunyang; Huang, Zhongren; Pan, Zhimin; Li, Zhiyun; Zhong, Junlong; Chen, Yiwei; Han, Zhimin; Cao, Kai

    2017-04-01

    This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion. To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine. Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called "notch-referred" technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated. Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared. A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The

  17. Comparative Analysis of Interval, Skipped, and Key-vertebral Pedicle Screw Strategies for Correction in Patients With Lenke Type 1 Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Wang, Fei; Xu, Xi-Ming; Lu, Yanghu; Wei, Xian-Zhao; Zhu, Xiao-Dong; Li, Ming

    2016-03-01

    Pedicle screw constructs have become the mainstay for surgical correction in patients with spinal deformities. To reduce or avoid the risk of pedicle screw-based complications and to decrease the costs associated with pedicle screw instrumentation, some authors have introduced interval, skipped, and key-vertebral pedicle screw strategies for correction. However, there have been no comparisons of outcomes among these 3 pedicle screw-placement strategies.The aim of this study was to compare the correlative clinical outcomes of posterior correction and fusion with pedicle screw fixation using these 3 surgical strategies.Fifty-six consecutive patients with Lenke type 1 adolescent idiopathic scoliosis were included in this study. Twenty patients were treated with the interval pedicle screw strategy (IPSS), 20 with the skipped pedicle screw strategy (SPSS), and 16 with the key-vertebral pedicle screw strategy (KVPSS). Coronal and sagittal radiographs were analyzed before surgery, at 1 week after surgery, and at the last follow-up after surgery.There were no significant differences among the 3 groups regarding preoperative radiographic parameters. No significant difference was found between the IPSS and SPSS groups in correction of the main thoracic curve (70.8% vs 70.0%; P = 0.524). However, there were statistically significant differences between the IPSS and KVPSS groups (70.8% vs 64.9%) and between the SPSS and KVPSS groups (70.0% vs 64.9%) in correction of the main thoracic curve (P SPSS group was significantly higher than those in the IPSS (P SPSS and KVPSS groups (P SPSS, it can achieve a satisfactory clinical outcome and is more cost-effective.

  18. Posterior Surgery for Adolescent Idiopathic Scoliosis With Pedicle Screws and Ultrahigh-Molecular Weight Polyethylene Tape: Achieving the Ideal Thoracic Kyphosis.

    Science.gov (United States)

    Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Ando, Kei; Hirano, Kenichi; Tauchi, Ryoji; Muramoto, Akio; Matsui, Hiroki; Matsumoto, Tomohiro; Sakai, Yoshihito; Katayama, Yoshito; Matsuyama, Yukihiro; Ishiguro, Naoki

    2016-10-01

    Prospective clinical case series. To describe our surgical procedure and results for posterior correction and fusion with a hybrid approach using pedicle screws, hooks, and ultrahigh-molecular weight polyethylene tape with direct vertebral rotation (DVR) (the PSTH-DVR procedure) for treatment of adolescent idiopathic scoliosis (AIS) with satisfactory correction in the coronal and sagittal planes. Introduction of segmental pedicle screws in posterior surgery for AIS has facilitated good correction and fusion. However, procedures using only pedicle screws have risks during screw insertion, higher costs, and decreased postoperative thoracic kyphosis. We have obtained good outcomes compared with segmental pedicle screw fixation in surgery for AIS using a relatively simple operative procedure (PSTH-DVR) that uses fewer pedicle screws. The subjects were 30 consecutive patients with AIS who underwent the PSTH-DVR procedure and were followed for a minimum of 2 years. Preoperative flexibility, preoperative and postoperative Cobb angles, correction rates, loss of correction, thoracic kyphotic angles (T5-T12), coronal balance, sagittal balance, and shoulder balance were measured on plain radiographs. Rib hump, operation time, estimated blood loss, spinal cord monitoring findings, complications, and scoliosis research society (SRS)-22 scores were also examined. The mean preoperative curve of 58.0 degrees (range, 40-96 degrees) was corrected to a mean of 9.9 degrees postoperatively, and the correction rate was 83.6%. Fusion was obtained in all patients without loss of correction. In 10 cases with preoperative kyphosis angles (T5-T12) correction of deformity with PSTH-DVR is equivalent to that of all-pedicle screw constructs. The procedure gives favorable correction, is advantageous for kyphosis compared with segmental screw fixation, and uses the minimum number of pedicle screws. Therefore, the PSTH-DVR procedure may be useful for treatment of idiopathic scoliosis.

  19. NONFUSION STABILIZATION IN THE DEGENERATIVE LUMBAR SPINE DISEASES

    Directory of Open Access Journals (Sweden)

    Matjaž Voršič

    2009-04-01

    Conclusions Cosmic is a posterior dynamic nonfusion pedicle screw-rod system for the stabilization of the lumbar vertebral column. It represents the new step in the development of the spinal instrumentation and can efficiently replace the spondylodesis in the treatment of painful degenerative diseases of the lumbar spine.

  20. First clinical results of minimally invasive vector lumbar interbody fusion (MIS-VLIF) in spondylodiscitis and concomitant osteoporosis: a technical note.

    Science.gov (United States)

    Rieger, Bernhard; Jiang, Hongzhen; Ruess, Daniel; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Tong, Huaiyu; Schackert, Gabriele

    2017-12-01

    First description of MIS-VLIF, a minimally invasive lumbar stabilization, to evaluate its safety and feasibility in patients suffering from weak bony conditions (lumbar spondylodiscitis and/or osteoporosis). After informed consent, 12 patients suffering from lumbar spondylodiscitis underwent single level MIS-VLIF. Eight of them had a manifest osteoporosis, either. Pre- and postoperative clinical status was documented using numeric rating scale (NRS) for leg and back pain. In all cases, the optimal height for the cage was preoperatively determined using software-based range of motion and sagittal balance analysis. CT scans were obtained to evaluate correct placement of the construct and to verify fusion after 6 months. Since 2013, 12 patients with lumbar pyogenic spondylodiscitis underwent MIS-VLIF. Mean surgery time was 169 ± 28 min and average blood loss was less than 400 ml. Postoperative CT scans showed correct placement of the implants. Eleven patients showed considerable postoperative improvement in clinical scores. In one patient, we observed screw loosening. After documented bony fusion in the CT scan, the fixation system was removed in two cases to achieve lower material load. The load-bearing trajectories (vectors) of MIS-VLIF are different from those of conventional coaxial pedicle screw implantation. The dorsally converging construct combines the heads of the dorsoventral pedicle screws with laminar pedicle screws following cortical bone structures within a small approach. In case of lumbar spondylodiscitis and/or osteoporosis, MIS-VLIF relies on cortical bony structures for all screw vectors and the construct does not depend on conventional coaxial pedicle screws in the presence of inflamed, weak, cancellous or osteoporotic bone. MIS-VLIF allows full 360° lumbar fusion including cage implantation via a small, unilateral dorsal midline approach.

  1. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    International Nuclear Information System (INIS)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W.

    2000-01-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  2. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W. [Dept. of Radiology, Univ. of Virginia Health System, Charlottesville, VA (United States)

    2000-12-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  3. Comparison of low density and high density pedicle screw instrumentation in Lenke 1 adolescent idiopathic scoliosis.

    Science.gov (United States)

    Shen, Mingkui; Jiang, Honghui; Luo, Ming; Wang, Wengang; Li, Ning; Wang, Lulu; Xia, Lei

    2017-08-02

    The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. We retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups. Comparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs.

  4. Translaminar screw fixation in the lumbar spine: technique, indications, results

    OpenAIRE

    Grob, D.; Humke, T.

    1998-01-01

    Translaminar screw fixation of the lumbar spine represents a simple and effective technique for short segment fusion in the degenerative spine. Clinical experience with 173 patients who underwent translaminar screw fixation revealed a fusion rate of 94%. The indications for translaminar screw fixation as a primary fixation procedure are: segmental dysfunction, lumbar spinal stenosis with painful degenerative changes, segmental revision surgery after discectomies, and painful disc-related synd...

  5. Fatigue life prediction of pedicle screw for spinal surgery

    Czech Academy of Sciences Publication Activity Database

    Major, Štěpán; Kocour, Vladimír; Cyrus, P.

    2016-01-01

    Roč. 10, č. 35 (2016), s. 379-388 ISSN 1971-8993. [European Conference on Fracture. ECF21. Catania, 20.06.2015-20.06.2015] Institutional support: RVO:68378297 Keywords : pedicle-screw * titan alloy * fatigue life * finite element analysis Subject RIV: JK - Corrosion ; Surface Treatment of Materials http://www.fracturae.com/index.php/fis/article/view/IGF-ESIS.35.43

  6. Metal Artifacts Reduction of Pedicle Screws on Spine Computed Tomography Images Using Variable Thresholding Technique

    International Nuclear Information System (INIS)

    Kaewlek, T.; Koolpiruck, D.; Thongvigitmanee, S.; Mongkolsuk, M.; Chiewvit, P.; Thammakittiphan, S.

    2012-01-01

    Metal artifacts are one of significant problems in computed tomography (CT). The streak lines and air gaps arise from metal implants of orthopedic patients, such as prosthesis, dental bucket, and pedicle screws that cause incorrect diagnosis and local treatment planning. A common technique to suppressed artifacts is by adjusting windows, but those artifacts still remain on the images. To improve the detail of spine CT images, the variable thresholding technique is proposed in this paper. Three medical cases of spine CT images categorized by the severity of artifacts (screws head, one full screw, and two full screws) were investigated. Metal regions were segmented by k-mean clustering, then transformed into a sinogram domain. The metal sinogram was identified by the variable thresholding method, and then replaced the new estimated values by linear interpolation. The modified sinogram was reconstructed by the filtered back- projection algorithm, and added the metal region back to the modified reconstructed image in order to reproduce the final image. The image quality of the proposed technique, the automatic thresholding (Kalender) technique, and window adjustment technique was compared in term of noise and signal to noise ratio (SNR). The propose method can reduce metal artifacts between pedicle screws. After processing by our proposed technique, noise in the modified images is reduced (screws head 121.15 to73.83, one full screw 160.88 to 94.04, and two full screws 199.73 to 110.05 from the initial image) and SNR is increased (screws head 0.87 to 1.88, one full screw 1.54 to 2.82, and two full screws 0.32 to 0.41 from the initial image). The variable thresholding technique can identify the suitable boundary for restoring the missing data. The efficiency of the metal artifacts reduction is indicated on the case of partial and full pedicle screws. Our technique can improve the detail of spine CT images better than automatic thresholding (Kalender) technique, and

  7. Navigation of Pedicle Screws in the Thoracic Spine with a New Electromagnetic Navigation System: A Human Cadaver Study

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    2015-01-01

    Full Text Available Introduction. Posterior stabilization of the spine is a standard procedure in spinal surgery. In addition to the standard techniques, several new techniques have been developed. The objective of this cadaveric study was to examine the accuracy of a new electromagnetic navigation system for instrumentation of pedicle screws in the spine. Material and Method. Forty-eight pedicle screws were inserted in the thoracic spine of human cadavers using EMF navigation and instruments developed especially for electromagnetic navigation. The screw position was assessed postoperatively by a CT scan. Results. The screws were classified into 3 groups: grade 1 = ideal position; grade 2 = cortical penetration <2 mm; grade 3 = cortical penetration ≥2 mm. The initial evaluation of the system showed satisfied positioning for the thoracic spine; 37 of 48 screws (77.1%, 95% confidence interval [62.7%, 88%] were classified as group 1 or 2. Discussion. The screw placement was satisfactory. The initial results show that there is room for improvement with some changes needed. The ease of use and short setup times should be pointed out. Instrumentation is achieved without restricting the operator’s mobility during navigation. Conclusion. The results indicate a good placement technique for pedicle screws. Big advantages are the easy handling of the system.

  8. Cost-Utility Analysis of Pedicle Screw Removal After Successful Posterior Instrumented Fusion in Thoracolumbar Burst Fractures.

    Science.gov (United States)

    Lee, Han-Dong; Jeon, Chang-Hoon; Chung, Nam-Su; Seo, Young-Wook

    2017-08-01

    A cost-utility analysis (CUA). The aim of this study was to determine the cost-effectiveness of pedicle screw removal after posterior fusion in thoracolumbar burst fractures. Pedicle screw instrumentation is a standard fixation method for unstable thoracolumbar burst fracture. However, removal of the pedicle screw after successful fusion remains controversial because the clinical benefits remain unclear. CUA can help clinicians make appropriate decisions about optimal health care for pedicle screw removal after successful fusion in thoracolumbar burst fractures. We conducted a single-center, retrospective, longitudinal matched-cohort study of prospectively collected outcomes. In total, 88 consecutive patients who had undergone pedicle screw instrumentation for thoracolumbar burst fracture with successful fusion confirmed by computed tomography (CT) were used in this study. In total, 45 patients wanted to undergo implant removal surgery (R group), and 43 decided not to remove the implant (NR group). A CUA was conducted from the health care perspective. The direct costs of health care were obtained from the medical bill of each patient. Changes in health-related quality of life (HRQoL) scores, validated by Short Form 6D, were used to calculate quality-adjusted life-years (QALYs). Total costs and gained QALY were calculated at 1 year (1 year) and 2 years (2 years) compared with baseline. Results are expressed as an incremental cost-effectiveness ratio (ICER). Different discount rates (0%, 3%, and 5%) were applied to both cost and QALY for sensitivity analysis. Baseline patient variables were similar between the two groups (all P > 0.05). The additional benefits of implant removal (0.201 QALY at 2 years) were achieved with additional costs ($2541 at 2 years), equating to an ICER of $12,641/QALY. On the basis of the different discount rates, the robustness of our study's results was also determined. Implant removal after successful fusion in a thoracolumbar burst

  9. Clinical study on the application of minimally invasive percutaneous pedicle screw fixation in single segment thoracolumbar fracture without neurological symptoms

    Directory of Open Access Journals (Sweden)

    Jin-ping LIU

    2016-04-01

    Full Text Available Objective To discuss the clinical effects of minimally invasive percutaneous pedicle screw fixation in the treatment of single segment thoracolumbar fracture without neurological symptoms.  Methods From June 2012 to October 2014, 38 neurologically intact patients with thoracolumbar fracture underwent surgeries, including open pedicle screw fixation in 16 cases and percutaneous pedicle screw fixation in 22 cases. The incision length, operation time, intraoperative blood loss, postoperative drainage and postoperative complication were recorded and compared between 2 groups. Thoracolumbar orthophoric, lateral and flexion-extension X-ray was used to measure sagittal Cobb angle and height of injured anterior vertebral body before and after operation. Modified Macnab evaluation was used to assess the curative effects 3 months after operation. Results The success rate of operations in 38 patients was 100%. There were a total of 114 vertebral bodies fused and 228 pedicle screws implanted. Patients in the percutaneous pedicle screw group had smaller incision length [(10.55 ± 1.23 cm vs (18.50 ± 2.50 cm, P = 0.000], less intraoperative blood loss [(32.55 ± 7.22 ml vs (320.50 ± 15.48 ml, P = 0.000], shorter hospital stay [(6.55 ± 1.50 d vs (13.50 ± 2.52 d, P = 0.000], and without postoperative drainage. The follow-up after operation ranged from 3 to 6 months, with the average time of (4.65 ± 1.24 months. Cobb angle was reduced (P = 0.000 and height of injured anterior vertebral body were improved signifcantly (P = 0.000 3 months after surgery in both groups. The total effective rate was 14/16 in open surgery group, and 86.36% (19/22 in percutaneous pedicle screw group, however, the difference between 2 groups was not significant (P = 1.000. Conclusions Minimally invasive percutaneous pedicle screw fixation is a surgical method with less iatrogenic injury, less intraoperative blood loss and quick recovery for patients with thoracolumbar fracture

  10. Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model

    OpenAIRE

    Krishnan, Venkatesh; Varghese, Vicky; Kumar, Gurunathan Saravana

    2016-01-01

    Study Design Biomechanical study. Purpose To determine the effect of density, insertion angle and reinsertion on pull-out strength of pedicle screw in single and two screw-rod configurations. Overview of Literature Pedicle screw pull-out studies have involved single screw construct, whereas two screws and rod constructs are always used in spine fusions. Extrapolation of results using the single screw construct may lead to using expensive implants or increasing the fusion levels specifically i...

  11. Use of next generation sequencing to detect biofilm bacteria in a patient with pedicle screw loosening after spine surgery

    DEFF Research Database (Denmark)

    Xu, Yijuan; Thomsen, Trine Rolighed; Lorenzen, Jan

    2016-01-01

    2. Center for Microbial Communities, Department of Biotechnology, Chemistry and Environmental Engineering, Aalborg University, Denmark 3. Otto-von-Guericke University Magdeburg, Department of Orthopedic Surgery, Magdeburg, Germany 4. Eifelklinik St. Brigida, Simmerath, Germany Aim: ”Hidden deep...... implant-related infection is believed to be linked to pedicle screw loosening after spine surgery. Low-grade bacterial infection can be hard to diagnose and may be undetected by conventional culture based methods. Next generation sequencing (NGS) could help to uncover hidden bacterial infections...... as a possible cause for implant loosening. This case report describes the use of NGS in the diagnostic work-up of a patient with pedicle screw loosening after spine surgery.” Method: ”A 60 y/o male had to undergo revision spine surgery for pedicle screw loosening and adjacent segment disease 3 years after...

  12. Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation.

    Science.gov (United States)

    Kong, Xiangxue; Tang, Lei; Ye, Qiang; Huang, Wenhua; Li, Jianyi

    2017-11-01

    Accurate and safe posterior thoracic pedicle insertion (PTPI) remains a challenge. Patient-specific drill templates (PDTs) created by rapid prototyping (RP) can assist in posterior thoracic pedicle insertion, but pose biocompatibility risks. The aims of this study were to develop alternative PDTs with computer numerical control (CNC) and assess their feasibility and accuracy in assisting PTPI. Preoperative CT images of 31 cadaveric thoracic vertebras were obtained and then the optimal pedicle screw trajectories were planned. The PDTs with optimal screw trajectories were randomly assigned to be designed and manufactured by CNC or RP in each vertebra. With the guide of the CNC- or RP-manufactured PDTs, the appropriate screws were inserted into the pedicles. Postoperative CT scans were performed to analyze any deviations at entry point and midpoint of the pedicles. The CNC group was found to be significant manufacture-time-shortening, and cost-decreasing, when compared with the RP group (P  0.05). The screw positions were grade 0 in 90.3% and grade 1 in 9.7% of the cases in the CNC group and grade 0 in 93.5% and grade 1 in 6.5% of the cases in the RP group (P = 0.641). CNC-manufactured PDTs are viable for assisting in PTPI with good feasibility and accuracy.

  13. Navigated pedicle screw placement using computed tomographic data in dorsolumbar fractures

    Directory of Open Access Journals (Sweden)

    Saurabh Kapoor

    2014-01-01

    Conclusion: CT-based navigation is effective in improving accuracy of pedicle screw placement in traumatic injuries of dorsolumbar spine (T9-L5, however additional cost of procuring CT scan to the patient and cost of equipment is of significant concern in developing countries. Reduced radiation exposure and lowered ergonomic constraints around the operation table are its additional benefits.

  14. Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases

    Directory of Open Access Journals (Sweden)

    Mark A Rivkin

    2014-01-01

    Full Text Available Summary of Background Data: Multilevel posterior cervical instrumented fusions are becoming more prevalent in current practice. Biomechanical characteristics of the cervicothoracic junction may necessitate extending the construct to upper thoracic segments. However, fixation in upper thoracic spine can be technically demanding owing to transitional anatomy while suboptimal placement facilitates vascular and neurologic complications. Thoracic instrumentation methods include free-hand, fluoroscopic guidance, and CT-based image guidance. However, fluoroscopy of upper thoracic spine is challenging secondary to vertebral geometry and patient positioning, while image-guided systems present substantial financial commitment and are not readily available at most centers. Additionally, imaging modalities increase radiation exposure to the patient and surgeon while potentially lengthening surgical time. Materials and Methods: Retrospective review of 44 consecutive patients undergoing a cervicothoracic fusion by a single surgeon using the novel free-hand T1 pedicle screw technique between June 2009 and November 2012. A starting point medial and cephalad to classic entry as well as new trajectory were utilized. No imaging modalities were employed during screw insertion. Postoperative CT scans were obtained on day 1. Screw accuracy was independently evaluated according to the Heary classification. Results: In total, 87 pedicle screws placed were at T1. Grade 1 placement occurred in 72 (82.8% screws, Grade 2 in 4 (4.6% screws and Grade 3 in 9 (10.3% screws. All Grade 2 and 3 breaches were <2 mm except one Grade 3 screw breaching 2-4 mm laterally. Only two screws (2.3% were noted to be Grade 4, both breaching medially by less than 2 mm. No new neurological deficits or returns to operating room took place postoperatively. Conclusions: This modification of the traditional starting point and trajectory at T1 is safe and effective. It attenuates additional bone

  15. Lumbar Spinal Stenosis Minimally Invasive Treatment with Bilateral Transpedicular Facet Augmentation System

    Energy Technology Data Exchange (ETDEWEB)

    Masala, Salvatore, E-mail: salva.masala@tiscali.it [Interventional Radiology and Radiotherapy, University of Rome ' Tor Vergata' , Department of Diagnostic and Molecular Imaging (Italy); Tarantino, Umberto [University of Rome ' Tor Vergata' , Department of Orthopaedics and Traumatology (Italy); Nano, Giovanni, E-mail: gionano@gmail.com [Interventional Radiology and Radiotherapy, University of Rome ' Tor Vergata' , Department of Diagnostic and Molecular Imaging (Italy); Iundusi, Riccardo [University of Rome ' Tor Vergata' , Department of Orthopaedics and Traumatology (Italy); Fiori, Roberto, E-mail: fiori.r@libero.it; Da Ros, Valerio, E-mail: valeriodaros@hotmail.com; Simonetti, Giovanni [Interventional Radiology and Radiotherapy, University of Rome ' Tor Vergata' , Department of Diagnostic and Molecular Imaging (Italy)

    2013-06-15

    Purpose. The purpose of this study was to evaluate the effectiveness of a new pedicle screw-based posterior dynamic stabilization device PDS Percudyn System Trade-Mark-Sign Anchor and Stabilizer (Interventional Spine Inc., Irvine, CA) as alternative minimally invasive treatment for patients with lumbar spine stenosis. Methods. Twenty-four consecutive patients (8 women, 16 men; mean age 61.8 yr) with lumbar spinal stenosis underwent implantation of the minimally invasive pedicle screw-based device for posterior dynamic stabilization. Inclusion criteria were lumbar stenosis without signs of instability, resistant to conservative treatment, and eligible to traditional surgical posterior decompression. Results. Twenty patients (83 %) progressively improved during the 1-year follow-up. Four (17 %) patients did not show any improvement and opted for surgical posterior decompression. For both responder and nonresponder patients, no device-related complications were reported. Conclusions. Minimally invasive PDS Percudyn System Trade-Mark-Sign has effectively improved the clinical setting of 83 % of highly selected patients treated, delaying the need for traditional surgical therapy.

  16. Lumbar Spinal Stenosis Minimally Invasive Treatment with Bilateral Transpedicular Facet Augmentation System

    International Nuclear Information System (INIS)

    Masala, Salvatore; Tarantino, Umberto; Nano, Giovanni; Iundusi, Riccardo; Fiori, Roberto; Da Ros, Valerio; Simonetti, Giovanni

    2013-01-01

    Purpose. The purpose of this study was to evaluate the effectiveness of a new pedicle screw-based posterior dynamic stabilization device PDS Percudyn System™ Anchor and Stabilizer (Interventional Spine Inc., Irvine, CA) as alternative minimally invasive treatment for patients with lumbar spine stenosis. Methods. Twenty-four consecutive patients (8 women, 16 men; mean age 61.8 yr) with lumbar spinal stenosis underwent implantation of the minimally invasive pedicle screw-based device for posterior dynamic stabilization. Inclusion criteria were lumbar stenosis without signs of instability, resistant to conservative treatment, and eligible to traditional surgical posterior decompression. Results. Twenty patients (83 %) progressively improved during the 1-year follow-up. Four (17 %) patients did not show any improvement and opted for surgical posterior decompression. For both responder and nonresponder patients, no device-related complications were reported. Conclusions. Minimally invasive PDS Percudyn System™ has effectively improved the clinical setting of 83 % of highly selected patients treated, delaying the need for traditional surgical therapy.

  17. Comparison of serum markers for muscle damage, surgical blood loss, postoperative recovery, and surgical site pain after extreme lateral interbody fusion with percutaneous pedicle screws or traditional open posterior lumbar interbody fusion.

    Science.gov (United States)

    Ohba, Tetsuro; Ebata, Shigeto; Haro, Hirotaka

    2017-10-16

    The benefits of extreme lateral interbody fusion (XLIF) as a minimally invasive lumbar spinal fusion treatment for lumbar degenerative spondylolisthesis have been unclear. We sought to evaluate the invasiveness and tolerability of XLIF with percutaneous pedicle screws (PPS) compared with traditional open posterior lumbar interbody fusion (PLIF). Fifty-six consecutive patients underwent open PLIF and 46 consecutive patients underwent single-staged treatment with XLIF with posterior PPS fixation for degenerative lumbar spondylolisthesis, and were followed up for a minimum of 1 year. We analyzed postoperative serum makers for muscle damage and inflammation, postoperative surgical pain, and performance status. A Roland-Morris Disability Questionnaire (RDQ) and Oswestry Disability Index (ODI) were obtained at the time of hospital admission and 1 year after surgery. Intraoperative blood loss (51 ± 41 ml in the XLIF/PPS group and 206 ± 191 ml in the PLIF group), postoperative WBC counts and serum CRP levels in the XLIF/PPS group were significantly lower than in the PLIF group. Postoperative serum CK levels were significantly lower in the XLIF/PPS group on postoperative days 4 and 7. Postoperative recovery of performance was significantly greater in the XLIF/PPS group than in the PLIF group from postoperative days 2 to 7. ODI and visual analog scale (VAS) score (lumbar) 1 year after surgery were significantly lower in the XLIF/PPS group compared with the PLIF group. The XLIF/PPS procedure is advantageous to minimize blood loss and muscle damage, with consequent earlier recovery of daily activities and reduced incidence of low back pain after surgery than with the open PLIF procedure.

  18. Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.

    Science.gov (United States)

    Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang

    2016-06-01

    To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration 4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P arm navigation compared to free-hand technique (2 vs. 15 %, P arm navigation (58 vs. 42 %, P arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.

  19. Cervical pedicle screw fixation at C6 and C7 A cadaveric study

    Directory of Open Access Journals (Sweden)

    Ye Li

    2015-01-01

    Conclusion: The intersection of the horizontal line through the midpoint of the transverse process root and vertical line through the intersection of the posterolateral and posterior planes of the isthmus can be used as an entry point for C6 and C7 pedicle screw fixation. The screws should be inserted at 60 or 90° with the posterolateral isthmus in the horizontal plane and at 75° with the posterior isthmus in the sagittal plane. The LSC should not exceed 30 mm.

  20. Unilateral pedicle screws asymmetric tethering: an innovative method to create idiopathic deformity

    Directory of Open Access Journals (Sweden)

    Zhang Xuesong

    2007-10-01

    Full Text Available Abstract Objective To evaluate the feasibility of the method that unilateral pedicle screws asymmetric tethering in concave side in combination with convex rib resection for creating idiopathic deformity. Summary of background data Various methods are performed to create idiopathic deformity. Among these methods, posterior asmmetric tethering of the spine shows satisfying result, but some drawbacks related to the current posterior asymmetric tether were still evident. Materials and methods Unilateral pedicle screws asymmetric tethering was performed to 14 female goats (age: 5–8 week-old, weight: 6–8 kg in concave side in combination with convex rib resection. Dorsoventral and lateral plain radiographs were taken of each thoracic spine in the frontal and sagittal planes right after the surgery and later every 4 weeks. Results All animals ambulated freely after surgery. For technical reasons, 2 goats were excluded (one animal died for anesthetic during the surgery, and one animal was lost for instrumental fail due to postoperative infection. Radiography showed that 11 goats exhibited scoliosis with convex toward to the right side, and as the curve increased with time, only 1 goat showed nonprogressive. The initial scoliosis generated in the progressors after the procedures measured 29.0° on average (range 23.0°–38.5° and increased to 43.0° on average (range 36.0°–58.0° over 8 to 10 weeks. The average progression of 14.0° was measured. The curvature immediately after tethering surgery (the initial Cobb angle did have a highly significant correlation with the final curvature (p Conclusion Unilateral pedicle screws asymmetric tethering is a practical method to create experimental scoliosis, especially for those who would like to study the correction of this deformity.

  1. Minimal access direct spondylolysis repair using a pedicle screw-rod system: a case series

    Directory of Open Access Journals (Sweden)

    Mohi Eldin Mohamed

    2012-11-01

    Full Text Available Abstract Introduction Symptomatic spondylolysis is always challenging to treat because the pars defect causing the instability needs to be stabilized while segmental fusion needs to be avoided. Direct repair of the pars defect is ideal in cases of spondylolysis in which posterior decompression is not necessary. We report clinical results using segmental pedicle-screw-rod fixation with bone grafting in patients with symptomatic spondylolysis, a modification of a technique first reported by Tokuhashi and Matsuzaki in 1996. We also describe the surgical technique, assess the fusion and analyze the outcomes of patients. Case presentation At Cairo University Hospital, eight out of twelve Egyptian patients’ acute pars fractures healed after conservative management. Of those, two young male patients underwent an operative procedure for chronic low back pain secondary to pars defect. Case one was a 25-year-old Egyptian man who presented with a one-year history of axial low back pain, not radiating to the lower limbs, after falling from height. Case two was a 29-year-old Egyptian man who presented with a one-year history of axial low back pain and a one-year history of mild claudication and infrequent radiation to the leg, never below the knee. Utilizing a standardized mini-access fluoroscopically-guided surgical protocol, fixation was established with two titanium pedicle screws place into both pedicles, at the same level as the pars defect, without violating the facet joint. The cleaned pars defect was grafted; a curved titanium rod was then passed under the base of the spinous process of the affected vertebra, bridging the loose fragment, and attached to the pedicle screw heads, to uplift the spinal process, followed by compression of the defect. The patients were discharged three days after the procedure, with successful fusion at one-year follow-up. No rod breakage or implant-related complications were reported. Conclusions Where there is no

  2. Increased incidence of pseudarthrosis after unilateral instrumented transforaminal lumbar interbody fusion in patients with lumbar spondylosis: Clinical article.

    Science.gov (United States)

    Gologorsky, Yakov; Skovrlj, Branko; Steinberger, Jeremy; Moore, Max; Arginteanu, Marc; Moore, Frank; Steinberger, Alfred

    2014-10-01

    Transforaminal lumbar interbody fusion (TLIF) with segmental pedicular instrumentation is a well established procedure used to treat lumbar spondylosis with or without spondylolisthesis. Available biomechanical and clinical studies that compared unilateral and bilateral constructs have produced conflicting data regarding patient outcomes and hardware complications. A prospective cohort study was undertaken by a group of neurosurgeons. They prospectively enrolled 80 patients into either bilateral or unilateral pedicle screw instrumentation groups (40 patients/group). Demographic data collected for each group included sex, age, body mass index, tobacco use, and Workers' Compensation/litigation status. Operative data included segments operated on, number of levels involved, estimated blood loss, length of hospital stay, and perioperative complications. Long-term outcomes (hardware malfunction, wound dehiscence, and pseudarthrosis) were recorded. For all patients, preoperative baseline and 6-month postoperative scores for Medical Outcomes 36-Item Short Form Health Survey (SF-36) outcomes were recorded. Patient follow-up times ranged from 37 to 63 months (mean 52 months). No patients were lost to follow-up. The patients who underwent unilateral pedicle screw instrumentation (unilateral cohort) were slightly younger than those who underwent bilateral pedicle screw instrumentation (bilateral cohort) (mean age 42 vs. 47 years, respectively; p = 0.02). No other significant differences were detected between cohorts with regard to demographic data, mean number of lumbar levels operated on, or distribution of the levels operated on. Estimated blood loss was higher for patients in the bilateral cohort, but length of stay was similar for patients in both cohorts. The incidence of pseudarthrosis was significantly higher among patients in the unilateral cohort (7 patients [17.5%]) than among those in the bilateral cohort (1 patient [2.5%]) (p = 0.02). Wound dehiscence occurred for

  3. The pedicle screw-rod system is an acceptable method of reconstructive surgery after resection of sacroiliac joint tumours

    Directory of Open Access Journals (Sweden)

    Yi-Jun Zhou

    2016-03-01

    Full Text Available Hemipelvic resections for primary bone tumours require reconstruction to restore weight bearing along anatomic axes. However, reconstruction of the pelvic arch remains a major surgical challenge because of the high rate of associated complications. We used the pedicle screw-rod system to reconstruct the pelvis, and the purpose of this investigation was to assess the oncology, functional outcome and complication rate following this procedure. The purpose of this study was to investigate the operative indications and technique of the pedicle screw-rod system in reconstruction of the stability of the sacroiliac joint after resection of sacroiliac joint tumours. The average MSTS (Musculoskeletal Tumour Society score was 26.5 at either three months after surgery or at the latest follow-up. Seven patients had surgery-related complications, including wound dehiscence in one, infection in two, local necrosis in four (including infection in two, sciatic nerve palsy in one and pubic symphysis subluxation in one. There was no screw loosening or deep vein thrombosis occurring in this series. Using a pedicle screw-rod after resection of a sacroiliac joint tumour is an acceptable method of pelvic reconstruction because of its reduced risk of complications and satisfactory functional outcome, as well as its feasibility of reconstruction for type IV pelvis tumour resection without elaborate preoperative customisation. Level of evidence: Level IV, therapeutic study.

  4. The role of bone SPECT/CT in the evaluation of lumbar spinal fusion with metallic fixation devices

    DEFF Research Database (Denmark)

    Damgaard, Morten; Nimb, Lars; Madsen, Jan L

    2010-01-01

    PURPOSE: It is difficult to evaluate the stability of the lumbar spondylodesis with metallic fixation devices by conventional imaging methods such as radiography or magnetic resonance imaging. It is unknown whether single photon emission computed tomography/computed tomography (SPECT/CT) may......, whereas in 1 case loose pedicle screws were detected at a wrong vertebral level. CONCLUSION: SPECT/CT may be useful to detect a lack of fixation of the metallic implants, and hence instability of the spondylodesis by evaluating the focal bone mineralization activity in relation to the pedicle screws....

  5. Mini-open transforaminal lumbar interbody fusion.

    Science.gov (United States)

    Tangviriyapaiboon, Teera

    2008-09-01

    To demonstrate the surgical technique and advantages of the mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation. Clinical and radiographic results were assessed to determine the clinical outcomes in twelve consecutive patients selected for minimally invasive access (mini-open technique) for TLIF in Prasat Neurological Institute. A retrospective analysis was performed on 12 patients (age range, 38-74 yr; mean, 54. 8 yr) who underwent mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation between September 2006 and June 2008. The titanium pedicle screws were introduced bilaterally through the 3.5 cm length, skin incisions with Spine Classics MLD- system retractor, autologous bone graft were inserted to perform TLIF in all patients. Eight patients were augmented anterior column support with titanium interbody cage, unilateral cage insertion in four patients and the others were inserted bilaterally interbody cages. Six patients presented with low back pain and associated radiculopathy, and six presented with low back pain only. Transforaminal lumbar interbody fusion was performed at L3-L4 in two patients, L4-L5 in four patients, L5-S1 in five patients, and two levels fusion in one patient. All patients were able to ambulate after spinal fusion. The patients were able to walk within 1.4 days (range 1-2 days). The hospital stay averaged 4.4 days (range 3-7 days). Periodic follow-up took place 1 to 21 months after surgery (mean, 7.4 months). The radiological fusion was archived in all nine patients who were operated on more than two months age. The other three patients who had been follow-up less than two months were probably fusion on the 1-month followed-up radiological examination. The use of mini-open technique for pedicle screw instrumentation with spinal fusion procedure provides excellent clinical results and may be an operation of choice for

  6. Comparison of revision strategies for failed C2-posterior cervical pedicle screws: a biomechanical study.

    Science.gov (United States)

    Mayer, Michael; Zenner, Juliane; Bogner, Robert; Hitzl, Wolfgang; Figl, Markus; von Keudell, Arvind; Stephan, Daniel; Penzkofer, Rainer; Augat, Peter; Korn, Gundobert; Resch, Herbert; Koller, Heiko

    2013-01-01

    With increasing usage within challenging biomechanical constructs, failures of C2 posterior cervical pedicle screws (C2-pCPSs) will occur. The purpose of the study was therefore to investigate the biomechanical characteristics of two revision techniques after the failure of C2-pCPSs. Twelve human C2 vertebrae were tested in vitro in a biomechanical study to compare two strategies for revision screws after failure of C2-pCPSs. C2 pedicles were instrumented using unicortical 3.5-mm CPS bilaterally (Synapse/Synthes, Switzerland). Insertion accuracy was verified by fluoroscopy. C2 vertebrae were potted and fixed in an electromechanical testing machine with the screw axis coaxial to the pullout direction. Pullout testing was conducted with load and displacement data taken continuously. The peak load to failure was measured in newtons (N) and is reported as the pullout resistance (POR). After pullout, two revision strategies were tested in each vertebra. In Group-1, revision was performed with 4.0-mm C2-pCPSs. In Group-2, revision was performed with C2-pedicle bone-plastic combined with the use of a 4-mm C2-pCPSs. For the statistical analysis, the POR between screws was compared using absolute values (N) and the POR of the revision techniques normalized to that of the primary procedures (%). The POR of primary 3.5-mm CPSs was 1,140.5 ± 539.6 N for Group-1 and 1,007.7 ± 362.5 N for Group-2; the difference was not significant. In the revision setting, the POR in Group-1 was 705.8 ± 449.1 N, representing a reduction of 38.1 ± 32.9 % compared with that of primary screw fixation. For Group-2, the POR was 875.3 ± 367.9 N, representing a reduction of 13.1 ± 23.4 %. A statistical analysis showed a significantly higher POR for Group-2 compared with Group-1 (p = 0.02). Although the statistics showed a significantly reduced POR for both revision strategies compared with primary fixation (p plastic, the POR can be significantly increased compared with the use of only an

  7. Multilevel Direct Repair Surgery for Three-Level Lumbar Spondylolysis

    Directory of Open Access Journals (Sweden)

    Tetsu Arai

    2013-01-01

    Full Text Available A 45-year-old man presented to our clinic requesting evaluation for surgical treatment of chronic low back pain of more than 20 years duration. He was diagnosed with 3-level lumbar spondylolysis at L3–5. Direct repair using the pedicle screw and hook-rod system was conducted for all three levels. After the surgery, his low back pain completely disappeared. Six months later, he felt discomfort and heard a metallic sound as he twisted his trunk. Computed tomography and radiography indicated that the hook head for L3 and the screw head for L4 were interfering with each other, causing the sound. We confirmed bony union at L3 and removed the L3 system. Surgeons should be aware of such complications if direct repair using a pedicle screw and hook-rod system is conducted for multilevel spondylolysis.

  8. Clinical effects of posterior pedicle screw fixation on spinal deformity in growing period: a report of 360 cases

    Directory of Open Access Journals (Sweden)

    Zheng-lei WANG

    2011-08-01

    Full Text Available Objective To observe the effect of a new kind of pedicle screw frame system with sliding terminus and locked middle segment on spinal deformity in growing period.Methods Three hundred and sixty patients in growing period were involved in the present study,and among them 82 were suffering from congenital scoliosis,218 idiopathic scoliosis and 60 kyphosis.All the patients were treated with the pedicle screw frame system with sliding terminus and locked middle segment.The treatment effects and postoperative complications were observed,and the Cobb angle before and after the operation was compared.Results The Cobb angle of 300 scoliosis patients was corrected from 53°±3° to 8°±2°,and the Cobb angle of 60 kyphosis patients was corrected from 60°±2° to 25°±3°,and the corrective effect was satisfactory.The correction rate of patients with Cobb angle ≤50° was 80%.Two hundred and ten patients were followed-up for 1 to 6 years,and the longitudinal growth of spine was 1.5-4.0cm.No severe complication,such as screw fracture,rod fracture or nerve injury,occurred.Conclusion The pedicle screw frame system with sliding terminus had a favorable three-dimensional correction effect,and the spine growth would not be restricted,and there was no stiffness,vertebral rotation,or distortion of shaft after operation.

  9. Complications in posterior lumbar interbody fusion

    OpenAIRE

    Kreuzer, Rolf-Peter

    2010-01-01

    From 1993 to 2000, 220 consecutive patients with unstable degenerative spondylolisthesis were studied after posterior lumbar interbody fusion (PLIF) using different types of grafts and pedicle screw systems. In a retrospective review the author detail the associated complications and their correlation with perioperative factors. The causes, strategies for their avoidance, and the clinical course of these complications are also disscused. The study group was composed of 136 women and 84 men...

  10. Feasibility study of patient-specific surgical templates for the fixation of pedicle screws.

    Science.gov (United States)

    Salako, F; Aubin, C-E; Fortin, C; Labelle, H

    2002-01-01

    Surgery for scoliosis, as well as other posterior spinal surgeries, frequently uses pedicle screws to fix an instrumentation on the spine. Misplacement of a screw can lead to intra- and post-operative complications. The objective of this study is to design patient-specific surgical templates to guide the drilling operation. From the CT-scan of a vertebra, the optimal drilling direction and limit angles are computed from an inverse projection of the pedicle limits. The first template design uses a surface-to-surface registration method and was constructed in a CAD system by subtracting the vertebra from a rectangular prism and a cylinder with the optimal orientation. This template and the vertebra were built using rapid prototyping. The second design uses a point-to-surface registration method and has 6 adjustable screws to adjust the orientation and length of the drilling support device. A mechanism was designed to hold it in place on the spinal process. A virtual prototype was build with CATIA software. During the operation, the surgeon places either template on patient's vertebra until a perfect match is obtained before drilling. The second design seems better than the first one because it can be reused on different vertebra and is less sensible to registration errors. The next step is to build the second design and make experimental and simulations tests to evaluate the benefits of this template during a scoliosis operation.

  11. Avaliação tomográfica do posicionamento de parafusos pediculares em deformidades na coluna torácica e lombar introduzidos com base na técnica "free hand" Evaluación tomográfica de la colocación de tornillos pediculares en deformidades de la columna torácica y lumbar, introducidos con base en la técnica "free hand" Tomographic evaluation of the placement of pedicle screws used in deformities of the thoracic and lumbar spine based on the "free hand" technique

    Directory of Open Access Journals (Sweden)

    Dante Bernardes Giubilei

    2011-01-01

    ículo, 244 (86% de los parafusos fueron colocados entre las corticales o apenas las tocaron. Lesión cortical lateral se observó en 16 tornillos y lesión cortical medial en 13 tornillos. Fue mayor el número de violaciones torácicas. CONCLUSIÓN: El uso de tornillos pediculares en la instrumentación de las vértebras torácicas y lumbares en la escoliosis demostró ser seguro y eficaz cuando se aplican a diferentes niveles con la técnica de "free hand''. En las vértebras torácicas, las violaciones de la cortical pedicular fueron más frecuentes, pero sin poner en peligro la estabilidad de la fijación y sin dañar estructuras neurales, vasculares y viscerales.OBJECTIVE: To evaluate the placement of pedicle screws in the vertebrae of the thoracic and lumbar spine in patients with scoliosis using the"free hand" technique. METHODS: Evaluation of CT scans of 284 pedicle screws in 15 patients (seven men and eight women aged between 12 and 39 years (mean 16.7 years with scoliosis. The screws were inserted from T2 to S1 for the following conditions: two congenital scoliosis and 13 neuromuscular, to evaluate the placement of screws in relation to the walls of pedicles. RESULTS: Regarding the cortical pedicle screws, 244 (86% were positioned between the cortical or just touching it. Lateral cortical lesion was seen in 16 screws and medial cortex lesion in 13 screws, being greater the number of violations in the thoracic vertebrae. CONCLUSION: The use of pedicle screw instrumentation in thoracic and lumbar vertebrae for scoliosis proved safe and effective when applied to different levels with the "free hand" technique. In the thoracic vertebrae, the pedicular cortical violations were more frequent, but did not impair the stability of fixation and did not injure the neural, vascular and visceral structures.

  12. Outcomes of percutaneous pedicle screw fixation for spinal trauma and tumours.

    Science.gov (United States)

    Mobbs, Ralph J; Park, Ashley; Maharaj, Monish; Phan, Kevin

    2016-01-01

    We investigated the clinical and radiological results of percutaneous pedicle screw fixation in the management of spinal trauma and metastatic tumours. A retrospective analysis was performed on a series of 14 patients who were operated on from March 2009 to November 2011 by a single surgeon (RJM). Following a radiological review (CT scan/MRI), six patients underwent short segment fixation, while the remaining underwent long segment fixation. All patients had routine follow-ups at 4, 6, 12months, and annually thereafter. Clinical examinations were conducted preoperatively and postoperatively, and the length of operation, blood loss, and postoperative pain relief were recorded. There was a single patient with an incision site complication. The mean blood loss was 269mL. All of the parameters demonstrated no significant differences between the trauma and the tumour groups (p=0.10). The neurological power scores improved for all patients, with the largest increase being from a score of 2 to 4. At follow-up, the majority of patients had returned to their previous activities and had reduced pain scores. One patient suffered high pain levels from other medical conditions that were not related to the operation. Minimally invasive pedicle screw fixation is a suitable option for patients with spinal tumours and fractures, with acceptable safety and efficacy in this small retrospective patient series. We have seen favourable results in our patients, who have experienced an increased quality of life following their surgery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Surgical results of a one-stage combined anterior lumbosacral fusion and posterior percutaneous pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Chien-Yuan Huang

    2018-01-01

    Full Text Available Objectives: Lumbosacral fusion through either an anterior or a posterior approach to achieve good lordosis and stability is always a challenging surgical operation and is often accompanied by a higher rate of pseudarthrosis than when other lumbar segments are involved. This study evaluated the clinical and radiological results of lumbosacral fusions achieved through a combined anterior and posterior approach. Materials and Methods: From June 2008 to 2012, 20 patients who had L5–S1 instability and stenosis were consecutively treated, first by anterior interbody fusion using an allogenous strut bone graft through the pararectus approach and then by posterior pedicle screw fixation. A minimum of 1-year of clinical and radiological follow-up was conducted. Intraoperative blood loss, surgical time, and any surgery-related complications were recorded. Clinical outcomes were assessed using a visual analog scale (VAS and the patient's Oswestry Disability Index (ODI score. After 1 year, radiological outcomes were assessed by analyzing pelvic incidence, lumbar lordosis, and segmental lordosis using static plain films, while fusion stability was assessed using dynamic plain films. Results: The mean operative time and blood loss were 215 min and 325 cc, respectively. After 1 year, the VAS and ODI scores had significantly improved, and stable fusion with good lordotic curvature was obtained in all cases. Conclusion: The surgical results of the combined procedure are satisfactory in terms of the functional and radiological outcomes. Our method offers advantages regarding both anterior fusion and posterior fixation.

  14. Biomechanics of an Expandable Lumbar Interbody Fusion Cage Deployed Through Transforaminal Approach

    Science.gov (United States)

    Mica, Michael Conti; Voronov, Leonard I.; Carandang, Gerard; Havey, Robert M.; Wojewnik, Bartosz

    2017-01-01

    Introduction A novel expandable lumbar interbody fusion cage has been developed which allows for a broad endplate footprint similar to an anterior lumbar interbody fusion (ALIF); however, it is deployed from a minimally invasive transforaminal unilateral approach. The perceived benefit is a stable circumferential fusion from a single approach that maintains the anterior tension band of the anterior longitudinal ligament. The purpose of this biomechanics laboratory study was to evaluate the biomechanical stability of an expandable lumbar interbody cage inserted using a transforaminal approach and deployed in situ compared to a traditional lumbar interbody cage inserted using an anterior approach (control device). Methods Twelve cadaveric spine specimens (L1-L5) were tested intact and after implantation of both the control and experimental devices in two (L2-L3 and L3-L4) segments of each specimen; the assignments of the control and experimental devices to these segments were alternated. Effect of supplemental pedicle screw-rod stabilization was also assessed. Moments were applied to the specimens in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). The effect of physiologic preload on construct stability was evaluated in FE. Segmental motions were measured using an optoelectronic motion measurement system. Results The deployable expendable TLIF cage and control devices significantly reduced FE motion with and without compressive preload when compared to the intact condition (p0.05). Adding bilateral pedicle screws resulted in further reduction of ROM for all loading modes compared to intact condition, with no statistical difference between the two constructs (p>0.05). Conclusions The ability of the deployable expendable interbody cage in reducing segmental motions was equivalent to the control cage when used as a stand-alone construct and also when supplemented with bilateral pedicle screw-rod instrumentation. The larger footprint of the fully

  15. Significance of magnetic resonance imaging signal change in the pedicle in the management of pediatric lumbar spondylolysis.

    Science.gov (United States)

    Sakai, Toshinori; Sairyo, Koichi; Mima, Seiichi; Yasui, Natsuo

    2010-06-15

    Prospective study. To investigate the time course of signal changes in the adjacent pedicle in fresh pediatric lumbar spondylolysis. A recent study reported that high signal change (HSC) on T2-magnetic resonance image (MRI) in the pedicle adjacent to the pars interarticularis could be an indicator of early spondylolysis. In addition, the HSC-positive pars defects showed significant better bony healing than the HSC-negative pars defects. However, there has been no report on the time course and the duration of HSC. We prospectively investigated 10 boys and 5 girls with fresh lumbar spondylolysis showing HSC in the adjacent pedicle. Their mean age was 15.1 years, ranging from 10 to 17 years. Two patients had multilevel unilateral spondylolysis. Among 15 patients, HSC was found in 22 (12 unilateral and 5 bilateral) pedicles. At the first presentation, the diagnosis of spondylolysis was made based on the plain radiograph findings, multidetector computed tomograms (CTs), and MRI. Every month from the first presentation, follow-up MRIs were taken. When HSC disappeared, multidetector CT was taken to confirm bony healing of the pars defect. Bony healing of the pars was obtained in 21 out of 22 defects. The bony healing rate was 95.6%. In 19 pedicles of 12 patients, HSC gradually diminished by every month until it disappeared 3 months later, and radiologic osseous healing was confirmed by CT in all but 1 patient. In the 3 remaining pedicles of 3 patients, HSC took more than 4 months to disappear. In this study, HSC disappeared in most pedicles on the 3-month follow-up MRI. In patients who did not comply with treatment, HSC tended to last longer. These results led us to hypothesize that MRI at the third month during follow-up can indicate whether the conservative treatment is being successful or not.

  16. Improving the trajectory of transpedicular transdiscal lumbar screw fixation with a computer-assisted 3D-printed custom drill guide

    Directory of Open Access Journals (Sweden)

    Zhen-Xuan Shao

    2017-07-01

    Full Text Available Transpedicular transdiscal screw fixation is an alternative technique used in lumbar spine fixation; however, it requires an accurate screw trajectory. The aim of this study is to design a novel 3D-printed custom drill guide and investigate its accuracy to guide the trajectory of transpedicular transdiscal (TPTD lumbar screw fixation. Dicom images of thirty lumbar functional segment units (FSU, two segments of L1–L4 were acquired from the PACS system in our hospital (patients who underwent a CT scan for other abdomen diseases and had normal spine anatomy and imported into reverse design software for three-dimensional reconstructions. Images were used to print the 3D lumbar models and were imported into CAD software to design an optimal TPTD screw trajectory and a matched custom drill guide. After both the 3D printed FSU models and 3D-printed custom drill guide were prepared, the TPTD screws will be guided with a 3D-printed custom drill guide and introduced into the 3D printed FSU models. No significant statistical difference in screw trajectory angles was observed between the digital model and the 3D-printed model (P > 0.05. Our present study found that, with the help of CAD software, it is feasible to design a TPTD screw custom drill guide that could guide the accurate TPTD screw trajectory on 3D-printed lumbar models.

  17. Biomechanical evaluation of bending strength of spinal pedicle screws, including cylindrical, conical, dual core and double dual core designs using numerical simulations and mechanical tests.

    Science.gov (United States)

    Amaritsakul, Yongyut; Chao, Ching-Kong; Lin, Jinn

    2014-09-01

    Pedicle screws are used for treating several types of spinal injuries. Although several commercial versions are presently available, they are mostly either fully cylindrical or fully conical. In this study, the bending strengths of seven types of commercial pedicle screws and a newly designed double dual core screw were evaluated by finite element analyses and biomechanical tests. All the screws had an outer diameter of 7 mm, and the biomechanical test consisted of a cantilever bending test in which a vertical point load was applied using a level arm of 45 mm. The boundary and loading conditions of the biomechanical tests were applied to the model used for the finite element analyses. The results showed that only the conical screws with fixed outer diameter and the new double dual core screw could withstand 1,000,000 cycles of a 50-500 N cyclic load. The new screw, however, exhibited lower stiffness than the conical screw, indicating that it could afford patients more flexible movements. Moreover, the new screw produced a level of stability comparable to that of the conical screw, and it was also significantly stronger than the other screws. The finite element analysis further revealed that the point of maximum tensile stress in the screw model was comparable to the point at which fracture occurred during the fatigue test. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Load-bearing evaluation of spinal posterior column by measuring surface strain from lumbar pedicles. An in vitro study.

    Science.gov (United States)

    Sun, Peidong; Zhao, Weidong; Bi, Zhenyu; Wu, Changfu; Ouyang, Jun

    2012-01-01

    An understanding of the load transfer within spinal posterior column of lumbar spine is necessary to determine the influence of mechanical factors on potential mechanisms of the motion-sparing implant such as artificial intervertebral disc and the dynamic spine stabilization systems. In this study, a new method has been developed for evaluating the load bearing of spinal posterior column by the surface strain of spinal pedicle response to the loading of spinal segment. Six cadaveric lumbar spine segments were biomechanically evaluated between levels L1 and L5 in intact condition and the strain gauges were pasted to an inferior surface of L2 pedicles. Multidirectional flexibility testing used the Panjabi testing protocol; pure moments for the intact condition with overall spinal motion and unconstrained intact moments of ±8 Nm were used for flexion-extension and lateral bending testing. High correlation coefficient (0.967-0.998) indicated a good agreement between the load of spinal segment and the surface strain of pedicle in all loading directions. Principal compressive strain could be observed in flexion direction and tensile strain in extension direction, respectively. In conclusion, the new method seems to be effective for evaluating posterior spinal column loads using pedicles' surface strain data collected during biomechanical testing of spine segments.

  19. Polyetheretherketone (PEEK) rods: short-term results in lumbar spine degenerative disease.

    Science.gov (United States)

    Colangeli, S; Barbanti Brodàno, G; Gasbarrini, A; Bandiera, S; Mesfin, A; Griffoni, C; Boriani, S

    2015-06-01

    Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the surgical treatment of lumbar spine degenerative disease. Rigid fixation leads to high fusion rates but may also contribute to stress shielding and adjacent segment degeneration. Thus, the use of semirigid rods made of polyetheretherketone (PEEK) has been proposed. Although the PEEK rods biomechanical properties, such as anterior load sharing properties, have been shown, there are few clinical studies evaluating their application in the lumbar spine surgical treatment. This study examined a retrospective cohort of patients who underwent posterior lumbar fusion for degenerative disease using PEEK rods, in order to evaluate the clinical and radiological outcomes and the incidence of complications.

  20. [Finite element analysis of stress changes of posterior spinal pedicle screw infixation].

    Science.gov (United States)

    Yan, Jia-Zhi; Wu, Zhi-Hong; Xu, Ri-Xin; Wang, Xue-Song; Xing, Ze-Jun; Zhao, Yu; Zhang, Jian-Guo; Shen, Jian-Xiong; Wang, Yi-Peng; Qiu, Gui-Xing

    2009-01-06

    To evaluate the mechanical response of L3-L4 segment after posterior interfixation with a transpedicle screw system. Spiral CT machine was used to conduct continuous parallel scan on the L3-L4 section of a 40-year-old healthy male Chinese. The image data thus obtained were introduced into MIMICS software to reconstruct the 2-D data into volume data and obtain 3-D models of every element.. Pro/3-D model construction software system was used to simulate the 3-D entity of L3-L4 fixed by screw robs through spinal pedicle via posterior approach that was introduced into the finite element software ABAQUS to construct a 3-D finite element model. The stress changes on the vertebrae and screw under the axial pressure of 0.5 mPa was analyzed. Under the evenly distributed pressure the displacement of the L4 model was 0.00125815 mm, with an error of only 0.8167% from the datum displacement. The convergence of the model was good. The stress of the fixed vertebral body, intervertebral disc, and internal fixators changed significantly. The stress concentration zone of the intervertebral disc turned from the posterolateral side to anterolateral side. The stress produced by the fixed vertebral bodies decreased significantly. Obvious stress concentration existed in the upper and lower sides of the base of screw and the fixed screw at the upper vertebral body bore greater stress than the lower vertebral body. Integration of computer aided device and finite element analysis can successfully stimulate the internal fixation of L3-IA visa posterior approach and observe the mechanic changes in the vertebral column more directly.

  1. Multiple Levels of Lumbar Spondylolysis - A Case Report -

    Science.gov (United States)

    Park, Kwang-Hwan; Ha, Joong-Won; Kim, Hak-Sun; Moon, Seong-Hwan; Lee, Hwan-Mo; Kim, Ho-Joong; Kim, Ju-Young

    2009-01-01

    We report here on an unusual case of multiple levels of asymmetric lumbar spondylolysis in a 19-year-old woman. The patient had severe low back pain of increasing intensity with lumbar instability, which was evident on the dynamic radiographs. MRI demonstrated the presence of abnormalities and the three dimensional CT scan revealed asymmetric complete spondylolysis at the left L2, L3 and L4 levels and the right L1, L2 and L3 levels. This case was treated surgically by posterior and posterolateral fusion at L2-3-4 with intersegmental fixation using pedicle screws and an auto iliac bone graft. The patient was relieved of her low back pain after the surgery. PMID:20404945

  2. Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep.

    Science.gov (United States)

    Wan, Shi-yong; Lei, Wei; Wu, Zi-xiang; Lv, Rong; Wang, Jun; Fu, Suo-chao; Li, Bo; Zhan, Ce

    2008-04-01

    To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive sections than non-expansive sections (P less than 0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

  3. Digitalized design of extraforaminal lumbar interbody fusion: a computer-based simulation and cadaveric study.

    Science.gov (United States)

    Yang, Mingjie; Zeng, Cheng; Guo, Song; Pan, Jie; Han, Yingchao; Li, Zeqing; Li, Lijun; Tan, Jun

    2014-01-01

    This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF), a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study. The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the superior articular process, dilation of the vertebral foramen, and placement of pedicle screws and a cage. ELIF anatomical measures were documented using a digitalized technique and subsequently validated on fresh cadavers. The use of the Mimics allowed for the vivid simulation of ELIF surgical procedures, while the cadaveric study proved the feasibility of this novel approach. ELIF had a relatively lateral access approach that was located 8-9 cm lateral to the median line with an access depth of approximately 9 cm through the intermuscular space. Dissection of the superior articular processes could fully expose the target intervertebral discs and facilitate a more inclined placement of the pedicle screws and cage with robust enhancement. According to the computer-based simulation and cadaveric study, it is feasible to perform ELIF. Further research including biomechanical study is needed to prove ELIF has a superior ability to preserve the posterior tension bands of the spinal column, with similar effects on spinal decompression, fixation, and fusion, and if it can enhance post-fusion spinal stability and expedites postoperative recovery.

  4. Analysis of risk factors for loss of lumbar lordosis in patients who had surgical treatment with segmental instrumentation for adolescent idiopathic scoliosis.

    Science.gov (United States)

    Trobisch, Per D; Samdani, Amer F; Betz, Randal R; Bastrom, Tracey; Pahys, Joshua M; Cahill, Patrick J

    2013-06-01

    Iatrogenic flattening of lumbar lordosis in patients with adolescent idiopathic scoliosis (AIS) was a major downside of first generation instrumentation. Current instrumentation systems allow a three-dimensional scoliosis correction, but flattening of lumbar lordosis remains a significant problem which is associated with decreased health-related quality of life. This study sought to identify risk factors for loss of lumbar lordosis in patients who had surgical correction of AIS with the use of segmental instrumentation. Patients were included if they had surgical correction for AIS with segmental pedicle screw instrumentation Lenke type 1 or 2 and if they had a minimum follow-up of 24 months. Two groups were created, based on the average loss of lumbar lordosis. The two groups were then compared and multivariate analysis was performed to identify parameters that correlated to loss of lumbar lordosis. Four hundred and seventeen patients were analyzed for this study. The average loss of lumbar lordosis at 24 months follow-up was an increase of 10° lordosis for group 1 and a decrease of 15° for group 2. Risk factors for loss of lumbar lordosis included a high preoperative lumbar lordosis, surgical decrease of thoracic kyphosis, and the particular operating surgeon. The lowest instrumented vertebra or spinopelvic parameters were two of many parameters that did not seem to influence loss of lumbar lordosis. This study identified important risk factors for decrease of lumbar lordosis in patients who had surgical treatment for AIS with segmental pedicle screw instrumentation, including a high preoperative lumbar lordosis, surgical decrease of thoracic kyphosis, and factors attributable to a particular operating surgeon that were not quantified in this study.

  5. Traumatic Fracture of Thin Pedicles Secondary to Extradural ...

    African Journals Online (AJOL)

    sequelae, secondary to local mass effect. Our objective is to report a technical case report, illustrating a traumatic spinal injury with multiple pedicle fractures, secondary to atrophic lumbar pedicles as well as the diagnostic workup and surgical management of this problem. Posterior lumbar decompression, resection of the ...

  6. Surgical outcome of posterior decompression, posterolateral fusion and stabilization by pedicle screw and rod in thoracolumbar tuberculosis

    Directory of Open Access Journals (Sweden)

    Md. Anowarul Islam

    2017-05-01

    Full Text Available Spinal tuberculosis causes severe complications like neurological and spinal deformity which may lead to respiratory distress, costo-pelvic impingement, paraplegia and consequent reduction in the quality and longevity of life. The aim of the present treatment is to avoid the consequence of neural complications and gain near-normal spine. Mechanical factor causes pathological fracture or dislocation of an affected vertebral body. Surgical decompression ensues further instability. Reconstruction of spinal column by pedicle screw and rod provide stability and prevents secondary neural damage and deformity thereby helps in early mobilization. Prospective study was done to evaluate the results in 20 cases of spinal tuberculosis in thoracolumbar region associated with neurological deficit. We operated our cases (12 males and 8 females by posterolateral decompression, fusion and stabilization by pedicle screw and rod along with antitubercular drug treatment. All patients were with neurological deficit, single level involvement and 10 to 30 degree of mild kyphosis. After surgery, kyphosis improved from 20.7 ± 5.5 degrees to 12.5 ± 3.9 degree. Bony fusion was in 65.0% cases. Neurological improvement and pain subsided in all the patients.

  7. Morphology study of thoracic transverse processes and its significance in pedicle-rib unit screw fixation.

    Science.gov (United States)

    Cui, Xin-gang; Cai, Jin-fang; Sun, Jian-min; Jiang, Zhen-song

    2015-03-01

    Thoracic transverse process is an important anatomic structure of the spine. Several anatomic studies have investigated the adjacent structures of the thoracic transverse process. But there is still a blank on the morphology of the thoracic transverse processes. The purpose of the cadaveric study is to investigate the morphology of thoracic transverse processes and to provide morphology basis for the pedicle-rib unit (extrapedicular) screw fixation method. Forty-five adult dehydrated skeletons (T1-T10) were included in this study. The length, width, thickness, and the tilt angle (upward and backward) of the thoracic transverse process were measured. The data were then analyzed statistically. On the basis of the morphometric study, 5 fresh cadavers were used to place screws from transverse processes to the vertebral body in the thoracic spine, and then observed by the naked eye and on computed tomography scans. The lengths of thoracic transverse processes were between 16.63±1.59 and 18.10±1.95 mm; the longest was at T7, and the shortest was at T10. The widths of thoracic transverse processes were between 11.68±0.80 and 12.87±1.48 mm; the widest was at T3, and the narrowest was at T7. The thicknesses of thoracic transverse processes were between 7.86±1.24 and 10.78±1.35 mm; the thickest was at T1, and the thinnest was at T7. The upward tilt angles of thoracic transverse processes were between 24.9±3.1 and 3.0±1.56 degrees; the maximal upward tilt angle was at T1, and the minimal upward tilt angle was at T7. The upward tilt angles of T1 and T2 were obviously different from the other thoracic transverse processes (Ptransverse processes gradually increased from 24.5±2.91 degrees at T1 to 64.5±5.12 degrees at T10. The backward tilt angles were significantly different between each other, except between T5 and T6. In the validation study, screws were all placed successfully from transverse processes to the vertebrae of thoracic spine. The length, width, and

  8. Range of motion, sacral screw and rod strain in long posterior spinal constructs: a biomechanical comparison between S2 alar iliac screws with traditional fixation strategies.

    Science.gov (United States)

    Sutterlin, Chester E; Field, Antony; Ferrara, Lisa A; Freeman, Andrew L; Phan, Kevin

    2016-12-01

    S1 screw failure and L5/S1 non-union are issues with long fusions to S1. Improved construct stiffness and S1 screw offloading can help avoid this. S2AI screws have shown to provide similar stiffness to iliac screws when added to L3-S1 constructs. We sought to examine and compare the biomechanical effects on an L2-S1 pedicle screw construct of adding S2AI screws, AxiaLIF, L5-S1 interbody support via transforaminal lumbar interbody fusion (TLIF), and to examine the effect of the addition of cross connectors to each of these constructs. Two S1 screws and one rod with strain gauges (at L5/S1) were used in L2-S1 screw-rod constructs in 7 L1-pelvis specimens (two with low BMD). ROM, S1 screw and rod strain were assessed using a pure-moment flexibility testing protocol. Specimens were tested intact, and then in five instrumentation states consisting of: (I) Pedicle screws (PS) L2-S1; (II) PS + S2AI screws; (III) PS + TLIF L5/S1; (IV) PS + AxiaLIF L5/S1; (V) PS + S2AI + AxiaLIF L5/S1. The five instrumentation conditions were also tested with crosslinks at L2/3 and S1/2. Tests were conducted in flexion-extension, lateral bending and axial torsion with no compressive preload. S2A1 produces reduced S1 screw strain for flexion-extension, lateral bending and axial torsion, as well as reduced rod strain in lateral bending and axial torsion in comparison to AxiaLIF and interbody instrumentation, at the expense of increased rod flexion-extension strain. Cross-connectors may have a role in further reduction of S1 screw and rod strain. From a biomechanical standpoint, the use of the S2AI technique is at least equivalent to traditional iliac screws, but offers lower prominence and ease of assembly compared to conventional sacroiliac stabilization.

  9. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.

    Science.gov (United States)

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.

  10. Comparison of pedicle screw-based dynamic stabilization and fusion surgery in the treatment of radiographic adjacent-segment degeneration: a retrospective analysis of single L5-S1 degenerative spondylosis covering 4 years.

    Science.gov (United States)

    Han, Yu; Sun, Jianguang; Luo, Chenghan; Huang, Shilei; Li, Liren; Ji, Xiang; Duan, Xiaozong; Wang, Zhenqing; Pi, Guofu

    2016-12-01

    OBJECTIVE Pedicle screw-based dynamic spinal stabilization systems (PDSs) were devised to decrease, theoretically, the risk of long-term complications such as adjacent-segment degeneration (ASD) after lumbar fusion surgery. However, to date, there have been few studies that fully proved that a PDS can reduce the risk of ASD. The purpose of this study was to examine whether a PDS can influence the incidence of ASD and to discuss the surgical coping strategy for L5-S1 segmental spondylosis with preexisting L4-5 degeneration with no related symptoms or signs. METHODS This study retrospectively compared 62 cases of L5-S1 segmental spondylosis in patients who underwent posterior lumbar interbody fusion (n = 31) or K-Rod dynamic stabilization (n = 31) with a minimum of 4 years' follow-up. The authors measured the intervertebral heights and spinopelvic parameters on standing lateral radiographs and evaluated preexisting ASD on preoperative MR images using the modified Pfirrmann grading system. Radiographic ASD was evaluated according to the results of radiography during follow-up. RESULTS All 62 patients achieved remission of their neurological symptoms without surgical complications. The Kaplan-Meier curve and Cox proportional-hazards model showed no statistically significant differences between the 2 surgical groups in the incidence of radiographic ASD (p > 0.05). In contrast, the incidence of radiographic ASD was 8.75 times (95% CI 1.955-39.140; p = 0.005) higher in the patients with a preoperative modified Pfirrmann grade higher than 3 than it was in patients with a modified Pfirrmann grade of 3 or lower. In addition, no statistical significance was found for other risk factors such as age, sex, and spinopelvic parameters. CONCLUSIONS Pedicle screw-based dynamic spinal stabilization systems were not found to be superior to posterior lumbar interbody fusion in preventing radiographic ASD (L4-5) during the midterm follow-up. Preexisting ASD with a modified Pfirrmann

  11. Clinical and radiological results 6 years after treatment of traumatic thoracolumbar burst fractures with pedicle screw instrumentation and balloon assisted endplate reduction

    NARCIS (Netherlands)

    Verlaan, Jorrit Jan; Somers, Inne; Dhert, Wouter J A; Oner, F. Cumhur

    2015-01-01

    Background context  When used to fixate traumatic thoracolumbar burst fractures, pedicle screw constructs may fail in the presence of severe vertebral body comminution as the intervertebral disc can creep through the fractured endplates leading to insufficient anterior column support.

  12. Segmental vs non-segmental thoracic pedicle screws constructs in adolescent idiopathic scoliosis: is there any implant alloy effect?

    Science.gov (United States)

    Di Silvestre, Mario; Bakaloudis, Georgeous; Ruosi, Carlo; Pipola, Valerio; Colella, Gianluca; Greggi, Tiziana; Ruffilli, Alberto; Vommaro, Francesco

    2017-10-01

    The aim of this study is to understand how many anchor sites are necessary to obtain maximum posterior correction of idiopathic scoliotic curve and if the alloy of instrumentation, stainless steel or titanium, may have a role in the percent of scoliosis correction. We reviewed 143 consecutive patients, affected by AIS (Lenke 1-2), who underwent a posterior spinal fusion with pedicle screw-only instrumentation between 2002 and 2005. According to the implant density and alloy used we divided the cohort in four groups. All 143 patients were reviewed at an average follow-up of 7, 2 years, the overall final main thoracic curve correction averaged 61.4%, whereas the implant density within the major curve averaged 71%. A significant correlation was observed between final% MT correction and preoperative MT flexibility and implant density. When stainless steel instrumentation is used non-segmental pedicle screw constructs seem to be equally effective as segmental instrumentations in obtaining satisfactory results in patients with main thoracic AIS. When the implant alloy used is titanium one, an implant density of ≥60% should be guaranteed to achieve similar results.

  13. Digitalized design of extraforaminal lumbar interbody fusion: a computer-based simulation and cadaveric study.

    Directory of Open Access Journals (Sweden)

    Mingjie Yang

    Full Text Available PURPOSE: This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF, a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study. METHODS: The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the superior articular process, dilation of the vertebral foramen, and placement of pedicle screws and a cage. ELIF anatomical measures were documented using a digitalized technique and subsequently validated on fresh cadavers. RESULTS: The use of the Mimics allowed for the vivid simulation of ELIF surgical procedures, while the cadaveric study proved the feasibility of this novel approach. ELIF had a relatively lateral access approach that was located 8-9 cm lateral to the median line with an access depth of approximately 9 cm through the intermuscular space. Dissection of the superior articular processes could fully expose the target intervertebral discs and facilitate a more inclined placement of the pedicle screws and cage with robust enhancement. CONCLUSIONS: According to the computer-based simulation and cadaveric study, it is feasible to perform ELIF. Further research including biomechanical study is needed to prove ELIF has a superior ability to preserve the posterior tension bands of the spinal column, with similar effects on spinal decompression, fixation, and fusion, and if it can enhance post-fusion spinal stability and expedites postoperative recovery.

  14. POSTERIOR LUMBAR INTERBODY FUSION AND INSTRUMENTED POSTEROLATERAL FUSION IN ADULT SPONDYLOLISTHESIS: ASSESSMENT AND CLINICAL OUTCOME

    Directory of Open Access Journals (Sweden)

    Rajarajan

    2015-11-01

    Full Text Available OBJECTIVE: Aim of this study is to assess and compare the outcomes of posterior lumbar interbody fusion (PLIF and posterolateral fusion (PLF in adult isthmic spondylosthesis. BACKGROUND: Posterolateral fusion has been considered the best method and widely been used for surgical treatment of adult spondylolisthesis.Superior results have subsequently been reported with interbody fusion with cages and posterior instrumentation MATERIALS AND METHODS: Thirty six patients with isthmic spondylolisthesis were operated. One group (20 patients had decompression and posterolateral fusion (PLF with a pedicle screw system; other group (16 patients was treated by decompression, posterior lumbar interbody fusion (PLIF and a Pedicle screw system. In both groups adequate decompression was done RESULTS: Seventy seven percent of the patients had a good result with (PLIF and 68 percent with posterolateral fusion (PLF. However there was no statistical difference in cases with low grade slipping, whereas the difference was significant for cases with high grade slipping. Fusion rate was 93% with (PLIF and 68% with (PLF, but without any significant incidence in the functional outcome. 78% has relief of sciatica and neurogenic claudication. CONCLUSION: Based on these findings we found that for high grade spondylolisthesis which requires reduction or if the disc space is still high posterior lumbar inter body fusion is preferable. For low grade spondylolisthesis or if the disc space is narrow posterolateral fusion is preferable. A successful result of fusion operation depends on adequate decompression which relieves radicular symptoms.

  15. Analysis of MRI signal changes in the adjacent pedicle of adolescent patients with fresh lumbar spondylolysis.

    Science.gov (United States)

    Goda, Yuichiro; Sakai, Toshinori; Sakamaki, Tadanori; Takata, Yoichiro; Higashino, Kosaku; Sairyo, Koichi

    2014-09-01

    The purpose of this study is to investigate a discrepancy between MRI and computed tomography (CT) findings in the spinal level distribution of spondylolysis. Recent advances in MRI have led to the early diagnosis of spondylolysis. Therefore, bony healing can be expected before the condition has a chance to worsen. In this study, we used MRI to examine the changes in spinal level signals in the pedicles adjacent to the pars interarticularis in adolescents with fresh lumbar spondylolysis. We then compared spinal level distribution of spondylolysis with that of previous results obtained by multidetector CT. The study included 98 adolescent patients (31 women and 67 men; mean age, 13.6 years; age range, 9-18 years) with fresh lumbar spondylolysis who showed MRI signal changes in the adjacent pedicle. An MRI signal change was defined as a high signal change on fat-suppressed imaging. MRI signal changes were detected in 150 adjacent pedicles of 101 vertebrae. Of these vertebrae, MRI signal changes in only 67 (66.3%) corresponded to L5, while changes in 34 (33.7%) corresponded to L3 or L4. In our follow-up study, the bone-healing rate with no vertebral defect was 100% at L3, 97.1% at L4, and 84.4% at L5. In addition, 11 of 34 (32.4%) vertebrae with signal changes at L3 or L4 occurred with L5 terminal-stage spondylolysis (no MRI signal change). MRI revealed a higher prevalence of L3 or L4 spondylolysis than observed with CT.

  16. Direct repair of defects in lumbar spondylolysis with a new pedicle screw hook fixation: clinical, functional and Ct-assessed study

    Science.gov (United States)

    Troussel, Serge

    2007-01-01

    Spondylolysis is a common entity, a minority of people affected by this disease need medical care, and only a few require surgery. Reconstruction of the pars interarticularis is an interesting alternative to segmental fusion; this technique has the advantage of preserving segmental motion. Most authors report good results for young patients without intervertebral disk or facet degenerative changes. Moreover Louis also showed good to excellent results with his technique carried out among people who presented a satisfactory disk height (equal to two thirds of normal height). This could extend the number of patients for whom pars interarticularis repair could be proposed. In this study, the limit of reconstruction was set at grade 3of the Pfirrmann’s classification. The fixation of the isthmus was done with a new kind of pedicle screw hook system. This stable and strong device is easy to use, allows an anatomic pars interarticularis reconstruction of spondylolysis and avoids a postoperative bracing. Twenty-three patients were assessed in this study, the mean age at operation was 34 (range 16–52 years) and the average follow-up was for 59 months (range 6–113 months). Eight patients showed moderate degenerative disk disease before the surgery and 12 patients had a grade 1 spondylolisthesis. The visual analogical scale, the Oswestry disability index (ODI) and the modified Prolo score were used for assessment of pain and clinical outcome before and after surgery. The results were from “excellent” to “good” for twenty patients (87%) and “fair” for three of them (13%). The consolidation of the isthmus was assessed at the end of the study (CT-scan); the fusion rate was observed in 91%. Among patients aged less than 30 years results are from “good”, to “excellent” in all cases and consolidation was always observed. All of them showed normal disc signal before the surgery. In the group aged more than 30 years, the results varied from

  17. Midline lumbar fusion using cortical bone trajectory screws. Preliminary report

    Directory of Open Access Journals (Sweden)

    Mateusz Bielecki

    2016-09-01

    Full Text Available Introduction : Midline lumbar fusion (MIDLF using cortical bone trajectory is an alternative method of transpedicular spinal fusion for degenerative disease. The new entry points’ location and screwdriving direction allow the approach-related morbidity to be reduced. Aim: To present our preliminary experience with the MIDLF technique on the first 5 patients with lumbar degenerative disease and with follow-up of at least 6 months. Material and methods: Retrospective analysis was performed on the first 5 patients with foraminal (4 or central (1 stenosis operated on between December 2014 and February 2015. Three patients were fused at L4–L5 and two at the L5–S1 level. Results: No intra- or post-operative complications occurred with this approach. An improvement regarding the leading symptom in the early postoperative period (sciatica 4/4, claudication 1/1 was achieved in all patients. The mean improvements in the visual analogue scale for low back and leg pain were 2.2 and 4.8 respectively. The mean Oswestry Disability Index scores were 52% (range: 16–82% before surgery and 33% (range: 12–56% at 3-month follow-up (mean improvement 19%. At the most recent follow-up, 4 patients reported the maintenance of the satisfactory result. The early standing and follow-up X-rays showed satisfactory screw placement in all patients. Conclusions : In our initial experience, the MIDLF technique seems to be an encouraging alternative to traditional transpedicular trajectory screws when short level lumbar fusion is needed. Nevertheless, longer observations on larger groups of patients are needed to reliably evaluate the safety of the method and the sustainability of the results.

  18. Biomechanical comparison of force levels in spinal instrumentation using monoaxial versus multi degree of freedom postloading pedicle screws.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Crandall, Dennis; Labelle, Hubert

    2011-01-15

    biomechanical analysis and simulations of correction mechanisms and force levels during scoliosis instrumentation using two types of pedicle screws and primary correction maneuvers. to biomechanically analyze implant-vertebra and inter-vertebral forces during scoliosis correction, to address the hypothesis that multi degree of freedom (MDOF) postloading screws with a direct incremental segmental translation (DIST) correction technique significantly reduce the loads as compared with monoaxial (MA) tulip-top design screws with a rod derotation technique (RDT). MA screw is widely used for spinal instrumentation. The MDOF screw was introduced as a refinement of the correction philosophy based on multiaxial screws. The kinematics of the MDOF construct is fundamentally different and offers more degrees of freedom than that of the MA construct; however, a systematic comparison of their biomechanics has not been done so far. a biomechanical model was developed to simulate the instrumentation of six scoliotic patients, first with the MDOF screws and DIST. Then, the instrumentation with MA screws and RDT was simulated using the same cases. Thirty more simulations were done to study the force-level sensitivity to small implant placement variation. there was a small average difference of 7°, 5°, and 4° between the two simulated systems for the computed main thoracic Cobb angle, kyphosis, and apical axial rotation, respectively. On average, the mean, standard deviation (SD), and maximum values of the implant-vertebra forces for MDOF screws were 56%, 59%, and 59%, respectively, lower than those for the MA screws, while the intervertebral forces for the MDOF screws were 31%, 37%, and 36% lower, respectively. Under the same set of random small implant placement changes, the mean, SD, and maximum values of implant-vertebra force magnitude changes for MDOF screws were 93%, 92%, and 95%, respectively, lower than those for MA screws. with MDOF screws and DIST, it is possible for

  19. Results of instrumented posterolateral fusion in treatment of lumbar spondylolisthesis with and without segmental kyphosis: A retrospective investigation

    Directory of Open Access Journals (Sweden)

    Szu-Yuan Chen

    2015-06-01

    Full Text Available Background: Treatment by posterolateral fusion (PLF with pedicle-screw instrumentation can be unsuccessful in one-segment and low-grade lumbar spondylolisthesis. Segmental kyphosis, either rigid or dynamic, was hypothesized to be one of the factors interfering with the fusion results. Methods: From 2004 to 2005, 239 patients with single-segment and low-grade spondylolisthesis were recruited and divided into two groups: Group 1 consisting of 129 patients without segmental kyphosis and group 2 consisting of 110 patients with segmental kyphosis. All patients underwent instrumented PLF at the same medical institute, and the average follow-up period was 31 ± 19 months. We obtained plain radiographs of the lumbosacral spine with the anteroposterior view, the lateral view, and the dynamic flexion-extension views before the operation and during the follow-ups. The results of PLF in the two groups were then compared. Results: There was no significant difference in the demographic data of the two groups, except for gender distribution. The osseous fusion rates were 90.7% in group 1 and 68.2% in group 2 (p < 0.001. Conclusion: Instrumented PLF resulted in significantly higher osseous fusion rate in patients without segmental kyphosis than in the patients with segmental kyphosis. For the patients with sagittal imbalance, such as rigid or dynamic kyphosis, pedicle-screw fixation cannot ensure successful PLF. Interbody fusion by the posterior lumbar interbody fusion or transforaminal lumbar interbody fusion technique might help overcome this problem.

  20. Time Demand and Radiation Dose in 3D-Fluoroscopy-based Navigation-assisted 3D-Fluoroscopy-controlled Pedicle Screw Instrumentations.

    Science.gov (United States)

    Balling, Horst

    2018-05-01

    Prospective single-center cohort study to record additional time requirements and radiation dose in navigation-assisted O-arm-controlled pedicle screw (PS) instrumentations. The aim of this study was to evaluate amount of extra-time and radiation dose for navigation-assisted PS instrumentations of the thoracolumbosacral spine using O-arm 3D-real-time-navigation (O3DN) compared to non-navigated spinal procedures (NNSPs) with a single C-arm and postoperative computed tomography (CT) scan for controlling PS positions. 3D-navigation is reported to enhance PS insertion accuracy. But time-consuming navigational steps and considerable additional radiation doses seem to limit this modern technique's attraction. A detailed analysis of additional time demand and extra-radiation dose in 3D-navigated spine surgery is not provided in literature, yet. From February 2011 through July 2015, 306 consecutive posterior instrumentations were performed in vertebral levels T10-S1 using O3DN for PS insertion. The duration of procedure-specific navigational steps of the overall collective (I) and the last cohort of 50 consecutive O3DN-surgeries (II) was compared to the average duration of analogous surgical steps in 100 consecutive NNSP using a single C-arm. 3D-radiation dose (dose-length-product, DLP) of navigational and postinstrumentation O-arm scans in group I and II was compared to the average DLP of 100 diagnostic lumbar CT scans. The average presurgical time from patient positioning on the operating table to skin incision was 46.2 ± 10.1 minutes (O3DN, I) and 40.6 ± 9.8 minutes (O3DN, II) versus 30.6 ± 8.3 minutes (NNSP) (P demand of 13.0 minutes compared to NNSP, and with a total DLP below that of a diagnostic lumbar CT scan (P ≈ 0.81). 4.

  1. The Effect of Lumbar Lordosis on Screw Loosening in Dynesys Dynamic Stabilization: Four-Year Follow-Up with Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao-Hung Kuo

    2015-01-01

    Full Text Available Introduction. This study aimed to evaluate the effects of Dynesys dynamic stabilization (DDS on clinical and radiographic outcomes, including spinal pelvic alignment. Method. Consecutive patients who underwent 1- or 2-level DDS for lumbar spondylosis, mild degenerative spondylolisthesis, or degenerative disc disease were included. Clinical outcomes were evaluated by Visual Analogue Scale for back and leg pain, Oswestry Disability Index, and the Japanese Orthopedic Association scores. Radiographic outcomes were assessed by radiographs and computed tomography. Pelvic incidence and lumbar lordosis (LL were also compared. Results. In 206 patients with an average follow-up of 51.1 ± 20.8 months, there were 87 screws (8.2% in 42 patients (20.4% that were loose. All clinical outcomes improved at each time point after operation. Patients with loosened screws were 45 years older. Furthermore, there was a higher risk of screw loosening in DDS involving S1, and these patients were more likely to have loosened screws if the LL failed to increase after the operation. Conclusions. The DDS screw loosening rate was overall 8.2% per screw and 20.4% per patient at more than 4 years of follow-up. Older patients, S1 involvement, and those patients who failed to gain LL postoperatively were at higher risk of screw loosening.

  2. Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis.

    Science.gov (United States)

    Leitner, Lukas; Malaj, Isabella; Sadoghi, Patrick; Amerstorfer, Florian; Glehr, Mathias; Vander, Klaus; Leithner, Andreas; Radl, Roman

    2018-04-13

    Spinal fusion is used for treatment of spinal deformities, degeneration, infection, malignancy, and trauma. Reduction of motion enables osseous fusion and permanent stabilization of segments, compromised by loosening of the pedicle screws (PS). Deep implant infection, biomechanical, and chemical mechanisms are suspected reasons for loosening of PS. Study objective was to investigate the frequency and impact of deep implant infection on PS loosening. Intraoperative infection screening from wound and explanted material sonication was performed during revision surgeries following dorsal stabilization. Case history events and factors, which might promote implant infections, were included in this retrospective survey. 110 cases of spinal metal explantation were included. In 29.1% of revision cases, infection screening identified a germ, most commonly Staphylococcus (53.1%) and Propionibacterium (40.6%) genus. Patients screened positive had a significant higher number of previous spinal operations and radiologic loosening of screws. Patients revised for adjacent segment failure had a significantly lower rate of positive infection screening than patients revised for directly implant associated reasons. Removal of implants that revealed positive screening effected significant pain relief. Chronic implant infection seems to play a role in PS loosening and ongoing pain, causing revision surgery after spinal fusion. Screw loosening and multiple prior spinal operations should be suspicious for implant infection after spinal fusion when it comes to revision surgery. These slides can be retrieved under Electronic Supplementary Material.

  3. Can intermuscular cleavage planes provide proper transverse screw angle? Comparison of two paraspinal approaches.

    Science.gov (United States)

    Cheng, Xiaofei; Ni, Bin; Liu, Qi; Chen, Jinshui; Guan, Huapeng

    2013-01-01

    The goal of this study was to determine which paraspinal approach provided a better transverse screw angle (TSA) for each vertebral level in lower lumbar surgery. Axial computed tomography (CT) images of 100 patients, from L3 to S1, were used to measure the angulation parameters, including transverse pedicle angle (TPA) and transverse cleavage plane angle (TCPA) of entry from the two approaches. The difference value between TCPA and TPA, defined as difference angle (DA), was calculated. Statistical differences of DA obtained by the two approaches and the angulation parameters between sexes, and the correlation between each angulation parameter and age or body mass index (BMI) were analyzed. TPA ranged from about 16° at L3 to 30° at S1. TCPA through the Wiltse's and Weaver's approach ranged from about -10° and 25° at L3 to 12° and 32° at S1, respectively. The absolute values of DA through the Weaver's approach were significantly lower than those through the Wiltse's approach at each level. The angulation parameters showed no significant difference with sex and no significant correlation with age or BMI. In the lower lumbar vertebrae (L3-L5) and S1, pedicle screw placement through the Weaver's approach may more easily yield the preferred TSA consistent with TPA than that through the Wiltse's approach. The reference values obtained in this paper may be applied regardless of sex, age or BMI and the descriptive statistical results may be used as references for applying the two paraspinal approaches.

  4. Posterior cervical spine arthrodesis with laminar screws. A report of two cases

    International Nuclear Information System (INIS)

    Nakanishi, Kazuo; Tanaka, Masato; Sugimoto, Yoshihisa; Ozaki, Toshifumi

    2007-01-01

    We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS). When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascular injury, so we used laminar screws. The other case was an 18-year-old man who had a hangman fracture. Preoperative magnetic resonance angiography showed occlusion of the left vertebral artery. A laminar screw was inserted into the patent side (i.e., the right side of C2). Cervical pedicle screws are the most biomechanically stable screws. However, their use carries a high risk of neurovascular complications during screw insertion, because the cervical pedicle is small and is adjacent laterally to the vertebral artery, medially to the spinal cord, and vertically to the nerve roots. Lateral mass screws are also reported to involve a risk of neurovascular injuries. The laminar screw method was thus thought to be useful, since arterial injuries could thus be avoided and it could also be used as a salvage modality for the previous misinsertion. (author)

  5. The application of data measurement before the pedicle vertebral arch fixed operation with spiral CT

    International Nuclear Information System (INIS)

    Yang Zenian; Luo Zhongyao; Chen Yong'an

    2003-01-01

    Objective: Authors carry out volume scans and 3D surface reconstruction. Then authors get the precise data of pedicle of vertebral arch, entering nail angle on horizontal direction, entering nail screw length, and the smallest horizontal diameter and entering nails' distance on pedicle of vertebral arch before the pedicle vertebral arch fixed operation. Method: Select the axial image of the widest pedicle of vertebral arch and it SSD image, measure the entering nail distance on the pedicle of vertebral arch, TSA, entering nail screw length, and the smallest horizontal diameter of the pedicle of vertebral arch. Result: The method helps to prepare the length, size and location of the nail and TSA for the pedicle of vertebral arch fixed operation, increase the operation success rate. Conclusion: This is a simple and reliable method to prepare the precise data of the nail length and size, TSA for the operation

  6. Percutaneous Facet Screw Fixation in the Treatment of Symptomatic Recurrent Lumbar Facet Joint Cyst: A New Technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas, E-mail: amorettinicolas@yahoo.fr; Gallo, Giacomo, E-mail: giacomo.gallo83@gmail.com; Bertrand, Anne-Sophie, E-mail: asbertrand3@hotmail.com [Centre Hospitalier Universitaire de Nice (France); Bard, Robert L., E-mail: rbard@cancerscan.com [New York Medical College (United States); Kelekis, Alexis, E-mail: akelekis@med.uoa.gr [University General Hospital “ATTIKON” (Greece)

    2016-01-15

    We present a case of percutaneous treatment of symptomatic recurrent lumbar facet joint cyst resistant to all medical treatments including facet joint steroid injection. Percutaneous transfacet fixation was then performed at L4–L5 level with a cannulated screw using CT and fluoroscopy guidance. The procedure time was 30 min. Using the visual analog scale (VAS), pain decreased from 9.5, preoperatively, to 0 after the procedure. At 6-month follow-up, an asymptomatic cystic recurrence was observed, which further reduced at the 1-year follow-up. Pain remained stable (VAS at 0) during all follow-ups. CT- and fluoroscopy-guided percutaneous cyst rupture associated with facet screw fixation could be an alternative to surgery in patients suffering from a symptomatic recurrent lumbar facet joint cyst.

  7. Outcome and safety analysis of 3D printed patient specific pedicle screw jigs for complex spinal deformities: A comparative study.

    Science.gov (United States)

    Garg, Bhavuk; Gupta, Manish; Singh, Menaka; Kalyanasundaram, Dinesh

    2018-05-03

    Spinal deformities are very challenging to treat and have a great risk of neurological complications due to hardware placement during corrective surgery. Various techniques have been introduced to ensure safe and accurate placement of pedicle screws. Patient-specific screw guides with pre-drawn and pre-validated trajectory seems to be an attractive option. We have focused on developing 3D printing technique for complex spinal deformities in India. This study also aimed to compare the placement of pedicle screw with 3D printing and free hand technique. This is a retrospective comparative clinical study at an academic institutional setting. A total of 20 patients were enrolled during the study, 10 were operated with the help of 3D printing (group 1) and 10 were operated with freehand technique (group 2). Group 1 included 6 congenital, 3 adolescent idiopathic scoliosis (AIS), one post tubercular kyphosis and Group 2 included 5 congenital, 4 AIS and one post tubercular kyphosis patient. Primary outcomes were measured in terms of screw violation and secondary outcome were measured in terms of Surgical time, Blood loss, Radiation exposure (no. of shoots required) and complications. MIMICS v18.0 Software was used for 3D reconstruction from CT scan images of all the patients. 3-Matic software was used to create drill guide. 3-D printer from Stratasys Mojo ABS P 430 model material cartilage (a thermoplastic material) was used for printing of vertebrae model and jigs. Two sample test of proportion was used to compare correctly and wrongly pedicle screw placement with 3D printing and freehand technique. T-test with equal variance was used for operating surgical time and blood loss. This work was carried out by collaboration of Orthopaedics Department, All India Institute of Medical Sciences (AIIMS), New Delhi and Biomedical Engineering Department, Indian Institute of Technology (IIT) Delhi. This project received the grant of USD 60000 from Department of Biotechnology (DBT

  8. Surgical treatment of degenerative and traumatic spinal diseases with expandable screws in patients with osteoporosis: 2-year follow-up clinical study.

    Science.gov (United States)

    Gazzeri, Roberto; Roperto, Raffaelino; Fiore, Claudio

    2016-11-01

    OBJECTIVE Pedicle screw instrumentation of the osteoporotic spine carries an increased risk of screw loosening, pullout, and fixation failure. A variety of techniques have been used clinically to improve pedicle screw fixation in the presence of compromised bone. Pedicle screws may be augmented with cement, but this may lead to cement leakage and result in disastrous consequences. To avoid these complications, a multiaxial expandable pedicle screw has been developed. This was a prospective, single-center study designed to evaluate the clinical results of patients with osteoporosis with traumatic and degenerative spinal diseases treated with expandable pedicle screws. METHODS Thirty-three patients (mean age 61.4 years) with osteoporosis and traumatic or degenerative spinal diseases underwent spinal posterior fixation with expandable screws. Preoperative and postoperative visual analog scale (VAS) for pain and Oswestry Disability Index (ODI) questionnaire scores were obtained. The immediate postoperative screw position was measured and compared with the final position on lateral plain radiographs and axial CT scans at the 1- and 2-year follow-up examinations. RESULTS A total of 182 pedicle screws were used, including 174 expandable and 8 regular screws. The mean preoperative patient VAS score improved from 8.2 to 3.6 after surgery. The mean ODI score improved from 83.7% before surgery to 29.7% after the operation and to 36.1% at the final follow-up. No screw migration had occurred at the 1-year follow-up, but 1 screw breakage/migration was visualized on spinal radiography at the 2-year follow-up. CONCLUSIONS The results of this study show that the multiaxial expandable pedicle screw is a safe and practical technique for patients with osteoporosis and various spinal diseases and adds a valuable tool to the armamentarium of spinal instrumentation.

  9. [Effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults].

    Science.gov (United States)

    Pu, Xiaobing; Yang, Shuangshi; Cao, Haiquan; Jing, Xingquan; Yin, Jun

    2014-03-01

    To investigate the effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults. Between January 2008 and December 2011, 32 patients with lumbar spondylolysis underwent U-shape titanium screw-rod fixation system with bone autografting. All patients were male with an average age of 22 years (range, 19-32 years). The disease duration ranged from 3 to 24 months (mean, 14 months). L3 was involved in spondylolysis in 2 cases, L4 in 10 cases, and L5 in 20 cases. The preoperative visual analogue scale (VAS) and Oswestry disability index (ODI) scores were 8.0 +/- 1.1 and 75.3 +/- 11.2, respectively. The operation time was 80-120 minutes (mean, 85 minutes), and the blood loss was 150-250 mL (mean, 210 mL). Primary healing of incision was obtained in all patients without complications of infection and nerve symptom. Thirty-two patients were followed up 12-24 months (mean, 14 months). Low back pain was significantly alleviated after operation. The VAS and ODI scores at 3 months after operation were 1.0 +/- 0.5 and 17.6 +/- 3.4, respectively, showing significant differences when compared with preoperative ones (t = 30.523, P = 0.000; t = 45.312, P = 0.000). X-ray films and CT showed bone fusion in the area of isthmus defects, with the bone fusion time of 6-12 months (mean, 9 months). During follow-up, no secondary lumbar spondyloly, adjacent segment degeneration, or loosening or breaking of internal fixator was found. The U-shape titanium screw-rod fixation system with bone autografting is a reliable treatment for lumbar spondylolysis of young adults because of a high fusion rate, minimal invasive, and maximum retention of lumbar range of motion.

  10. Evaluation of Outcome of Posterior Decompression and Instrumented Fusion in Lumbar and Lumbosacral Tuberculosis.

    Science.gov (United States)

    Jain, Akshay; Jain, Ravikant; Kiyawat, Vivek

    2016-09-01

    For surgical treatment of lumbar and lumbosacral tuberculosis, the anterior approach has been the most popular approach because it allows direct access to the infected tissue, thereby providing good decompression. However, anterior fixation is not strong, and graft failure and loss of correction are frequent complications. The posterior approach allows circumferential decompression of neural elements along with three-column fixation attained via pedicle screws by the same approach. The purpose of this study was to evaluate the outcome (functional, neurological, and radiological) in patients with lumbar and lumbosacral tuberculosis operated through the posterior approach. Twenty-eight patients were diagnosed with tuberculosis of the lumbar and lumbosacral region from August 2012 to August 2013. Of these, 13 patients had progressive neurological deterioration or increasing back pain despite conservative measures and underwent posterior decompression and pedicle screw fixation with posterolateral fusion. Antitubercular therapy was given till signs of radiological healing were evident (9 to 16 months). Functional outcome (visual analogue scale [VAS] score for back pain), neurological recovery (Frankel grading), and radiological improvement were evaluated preoperatively, immediately postoperatively and 3 months, 6 months, and 1 year postoperatively. The mean VAS score for back pain improved from 7.89 (range, 9 to 7) preoperatively to 2.2 (range, 3 to 1) at 1-year follow-up. Frankel grading was grade B in 3, grade C in 7, and grade D in 3 patients preoperatively, which improved to grade D in 7 and grade E in 6 patients at the last follow-up. Radiological healing was evident in the form of reappearance of trabeculae formation, resolution of pus, fatty marrow replacement, and bony fusion in all patients. The mean correction of segmental kyphosis was 9.85° postoperatively. The mean loss of correction at final follow-up was 3.15°. Posterior decompression with instrumented

  11. A STUDY OF POSTERIOR LUMBAR INTERBODY FUSION WITH LOCALLY HARVESTED SPINOLAMINECTOMY BONE GRAFT AND PEDICLE SCREW FIXATION IN SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Pardhasaradhi M

    2017-08-01

    Full Text Available BACKGROUND Posterior Lumbar Interbody Fusion (PLIF and Transforaminal Lumbar Interbody Fusion (TLIF create intervertebral fusion by means of a posterior approach. Successful results have been reported with allograft, various cages (for interbody support, autograft and recombinant human bone morphogenetic protein‐2. Interbody fusion techniques facilitate reduction and enhance fusion. Corticocancellous laminectomy bone chips alone can be used as a means of spinal fusion in patients with single level instrumented PLIF. This has got a good fusion rate. PLIF with cage gives better fusion on radiology than PLIF with iliac bone graft, but no statistical difference in the clinical outcome. Cage use precludes complications associated with iliac bone harvesting. The reported adjacent segment degeneration was 40.5% and reoperation was 8.1% after 10 years of follow up. MATERIALS AND METHODS 30 cases of spondylolisthesis who attended the Orthopaedic Outpatient Department of Andhra Medical College, Visakhapatnam, from 2014 to 2016 were taken up for study. All the cases were examined clinically and confirmed radiologically. The patient’s age, sex, symptoms and duration were noted and were examined clinically for the status of the spine. Straight leg raising test was done and neurological examination of the lower limbs performed. All the patients were subjected to the radiological examination of the lumbosacral spine by taking anteroposterior, lateral (flexion and extension views, oblique views to demonstrate spondylolysis and spondylolisthesis. MRI and x-rays studies were done in all the cases to facilitate evaluation of the root compression disk changes and spinal cord changes. RESULTS In our study, we followed all the 30 patients after the surgery following procedure of removal of loose lamina, spinous process and fibrocartilaginous mass, PLIF with only the laminectomy bone mass and CD screw system fixation up to 2 years. 12 patients (40% had excellent

  12. Pedicle measurement of the thoracolumbar spine: a cadaveric, radiographic, and CT scan study in Filipinos

    International Nuclear Information System (INIS)

    Molano, A.M.V.; Sison, A.B.; Fong, H.C.; Lim, N.T.; Sabile, K.

    1994-01-01

    With the popular usage of spinal pedicular screw fixation, it is essential to have a knowledge of the morphometry of the pedicles of the spine of particular populations. This study compared the direct pedicle measurements of ten cadavers in an institution, with their respective radiographic and computerized tomographic (CT) scan values, and also compared the effective pedicle diameter (EPD) with the conventional outer pedicle diameter (OPD) measurements. A compilation of pedicle values was also made in X-ray and CT scan plates of a Filipino population. A statistical analysis made on the 2,760 pedicle measurements taken from cadaveric T6-L5 vertebrae showed that direct measurements were significantly different from X-ray and CT scan values. The mean values of the EPD differed from those of the OPD, but not statistically significant. Comparison with previous foreign studies revealed significant differences in these pedicle dimensions. Pedicle measurements in a living Filipino population were found to be significantly different statistically between sexes. Accurate measurement of the pedicle diameters and lengths are indeed critical for the success of a spinal stabilization procedure using pedicular screws. (author). 8 refs.; 5 figs.; 1 tab

  13. iPod touch-assisted instrumentation of the spine: a technical report.

    Science.gov (United States)

    Jost, Gregory F; Bisson, Erica F; Schmidt, Meic H

    2013-12-01

    Instrumentation of the spine depends on choosing the correct insertion angles to implant screws. Although modern image guidance facilitates precise instrumentation of the spine, the equipment is costly and availability is limited. Although most surgeons use lateral fluoroscopy to guide instrumentation in the sagittal plane, the lateromedial angulation is often chosen by estimation. To overcome the associated uncertainty, iPod touch-based applications for measuring angles can be used to assist with screw implantation. To evaluate the use of the iPod touch to adjust instruments to the optimal axial insertion angle for placement of pedicle screws in the lumbar spine. Twenty lumbar pedicle screws in 5 consecutive patients were implanted using the iPod touch. The lateromedial angulation was measured on preoperative images and reproduced in the operative field with the iPod touch. The instruments to implant the screws were aligned with the side of the iPod for screw insertion. Actual screw angles were remeasured on postoperative imaging. We collected demographic, clinical, and operative data for each patient. In 16 of 20 screws, the accuracy of implantation was within 3 degrees of the ideal trajectory. The 4 screws with an angle mismatch of 7 to 13 degrees were all implanted at the caudal end of the exposure, where maintaining the planned angulation was impeded by strong muscles pushing medially. iPod touch-assisted instrumentation of the spine is a very simple technique, which, in combination with a lateral fluoroscopy, may guide placement of pedicle screws in the lumbar spine.

  14. Asymmetry of the Vertebral Body and Pedicles in the True Transverse Plane in Adolescent Idiopathic Scoliosis: A CT-Based Study.

    Science.gov (United States)

    Brink, Rob C; Schlösser, Tom P C; Colo, Dino; Vincken, Koen L; van Stralen, Marijn; Hui, Steve C N; Chu, Winnie C W; Cheng, Jack C Y; Castelein, René M

    2017-01-01

    Cross-sectional. To quantify the asymmetry of the vertebral bodies and pedicles in the true transverse plane in adolescent idiopathic scoliosis (AIS) and to compare this with normal anatomy. There is an ongoing debate about the existence and magnitude of the vertebral body and pedicle asymmetry in AIS and whether this is an expression of a primary growth disturbance, or secondary to asymmetrical loading. Vertebral body asymmetry, defined as left-right overlap of the vertebral endplates (ie, 100%: perfect symmetry, 0%: complete asymmetry) was evaluated in the true transverse plane on CT scans of 77 AIS patients and 32 non-scoliotic controls. Additionally, the pedicle width, length, and angle and the length of the ideal screw trajectory were calculated. Scoliotic vertebrae were on average more asymmetric than controls (thoracic: AIS 96.0% vs. controls 96.4%; p = .005, lumbar: 95.8% vs. 97.2%; p transverse pedicle angle was greater (12.3° vs. 5.7°; p transverse plane in AIS and no uniform relation between the axial rotation and vertebral asymmetry could be observed in these moderate to severe patients, suggesting that asymmetrical vertebral growth does not initiate rotation, but rather follows it as a secondary phenomenon. Level 4. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  15. Mid-range outcomes in 64 consecutive cases of multilevel fusion for degenerative diseases of the lumbar spine

    Directory of Open Access Journals (Sweden)

    Marc Röllinghoff

    2010-01-01

    Full Text Available In the treatment of multilevel degenerative disorders of the lumbar spine, spondylodesis plays a controversial role. Most patients can be treated conservatively with success. Multilevel lumbar fusion with instrumentation is associated with severe complications like failed back surgery syndrome, implant failure, and adjacent segment disease (ASD. This retrospective study examines the records of 70 elderly patients with degenerative changes or instability of the lumbar spine treated between 2002 and 2007 with spondylodesis of more than two segments. Sixty-four patients were included; 5 patients had died and one patient was lost to follow-up. We evaluated complications, clinical/radiological outcomes, and success of fusion. Flexion-extension and standing X-rays in two planes, MRI, and/or CT scans were obtained pre-operatively. Patients were assessed clinically using the Oswestry disability index (ODI and a Visual Analogue Scale (VAS. Surgery performed was dorsolateral fusion (46.9% or dorsal fusion with anterior lumbar interbody fusion (ALIF; 53.1%. Additional decompression was carried out in 37.5% of patients. Mean follow-up was 29.4±5.4 months. Average patient age was 64.7±4.3 years. Clinical outcomes were not satisfactory for all patients. VAS scores improved from 8.6±1.3 to 5.6±3.0 pre- to post-operatively, without statistical significance. ODI was also not significantly improved (56.1±22.3 pre- and 45.1±26.4 post-operatively. Successful fusion, defined as adequate bone mass with trabeculation at the facets and transverse processes or in the intervertebral segments, did not correlate with good clinical outcomes. Thirty-five of 64 patients (54% showed signs of pedicle screw loosening, especially of the screws at S1. However, only 7 of these 35 (20% complained of corresponding back pain. Revision surgery was required in 24 of 64 patients (38%. Of these, indications were adjacent segment disease (16 cases, pedicle screw loosening (7 cases

  16. Optimization of spinal implant screw for lower vertebra through finite element studies.

    Science.gov (United States)

    Biswas, Jayanta; Karmakar, Santanu; Majumder, Santanu; Banerjee, Partha Sarathi; Saha, Subrata; Roychowdhury, Amit

    2014-01-01

    The increasing older population is suffering from an increase in age-related spinal degeneration that causes tremendous pain. Spine injury is mostly indicated at the lumbar spine (L3-L5) and corresponding intervertebral disks. Finite element analysis (FEA) is now one of the most efficient and accepted tools used to simulate these pathological conditions in computer-assisted design (CAD) models. In this study, L3-L5 spines were modeled, and FEA was performed to formulate optimal remedial measures. Three different loads (420, 490.5, and 588.6 N) based on three body weights (70, 90, and 120 kg) were applied at the top surface of the L3 vertebra, while the lower surface of the L5 vertebra remained fixed. Models of implants using stainless steel and titanium alloy (Ti6Al4V) pedicle screws and rods with three different diameters (4, 5, and 6 mm) were inserted into the spine models. The relative strengths of bone (very weak, weak, standard, strong, and very strong) were considered to determine the patient-specific effect. A total of 90 models were simulated, and von Mises stress and strain, shear stress, and strain intensity contour at the bone-implant interface were analyzed. Results of these analyses indicate that the 6-mm pedicle screw diameter is optimal for most cases. Experimental and clinical validation are needed to confirm these theoretical results.

  17. Percutaneous pedicle screw for unstable spine fractures in polytraumatized patients: A report of two cases

    Directory of Open Access Journals (Sweden)

    Boon Beng Tan

    2012-01-01

    Full Text Available Unstable spine fractures commonly occur in the setting of a polytraumatized patient. The aim of management is to balance the need for early operative stabilization and prevent additional trauma due to the surgery. Recent published literature has demonstrated the benefits of early stabilization of an unstable spine fracture particularly in patients with higher injury severity score (ISS. We report two cases of polytrauma with unstable spine fractures stabilized with a minimally invasive percutaneous pedicle screw instrumentation system as a form of damage control surgery. The patients had good recovery from the polytrauma injuries. These two cases illustrate the role of minimally invasive stabilization, its limitations and technical pitfalls in the management of unstable spine fractures in the polytrauma setting as a form of damage control surgery.

  18. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  19. Comparison of Direct Pars Repair Techniques of Spondylolysis in Pediatric and Adolescent Patients: Pars Compression Screw Versus Pedicle Screw-Rod-Hook.

    Science.gov (United States)

    Karatas, Ali F; Dede, Ozgur; Atanda, Alfred A; Holmes, Larry; Rogers, Kenneth; Gabos, Peter; Shah, Suken A

    2016-08-01

    Retrospective clinical cohort study. To compare the clinical and radiographic outcomes of patients who were treated with intrasegmental pars fixation by either laminar compression screw (LS) or a pedicle screw, rod, and laminar hook (PSRH) construct. Spondylolysis is a nonunion defect of the pars interarticularis. In symptomatic spondylolysis, direct repair of the pars interarticularis defect can preserve motion and prevent abnormal stresses at the adjacent levels. Sixteen patients who failed nonoperative treatment and underwent direct pars repair by using LS (n=9) or PSRH (n=7) constructs were included in the study. Clinical outcome was assessed by using the MacNab criteria. Radiologic fusion and complications were evaluated using plain radiographs or computed tomography images and patient charts. The healing rate was 100% after 6 months. The healing time was similar in both the groups: LS, 6.5 months; PSRH, 6.2 months. Patients with PSRH (5.9 mo) were more likely to return to sports earlier relative to patients with LS (7.7 mo). There were no complications in the LS group; in the PSRH group, 1 patient had mild sensory deficit and 2 had superficial wound infections. The MacNab criteria for pain assessment showed an excellent or good outcome in 8 of 9 patients in LS group and 6 of 7 patients in PSRH group. Relative to LS patients, there was a significant increase in surgical time and estimated blood loss among PSRH patients. Either of the mentioned 2 techniques appears to produce acceptable results. Biplanar fluoroscopy and navigation systems could minimize the risk of screw misplacement with LS construct. Familiarity with the various fixation techniques will allow the surgeon to select the most appropriate surgical technique.

  20. Postoperative quality-of-life assessment in patients with spine metastases treated with long-segment pedicle-screw fixation.

    Science.gov (United States)

    Bernard, Florian; Lemée, Jean-Michel; Lucas, Olivier; Menei, Philippe

    2017-06-01

    OBJECTIVE In recent decades, progress in the medical management of cancer has been significant, resulting in considerable extension of survival for patients with metastatic disease. This has, in turn, led to increased attention to the optimal surgical management of bone lesions, including metastases to the spine. In addition, there has been a shift in focus toward improving quality of life and reducing hospital stay for these patients, and many minimally invasive techniques have been introduced with the aim of reducing the morbidity associated with more traditional open approaches. The goal of this study was to assess the efficacy of long-segment percutaneous pedicle screw stabilization for the treatment of instability associated with thoracolumbar spine metastases in neurologically intact patients. METHODS This study was a retrospective review of data from a prospective database. The authors analyzed cases in which long-segment percutaneous pedicle screw fixation was performed for the palliative treatment of thoracolumbar spinal instability due to spinal metastases in neurologically intact patients. All of the patients included in the study underwent surgery between January 2014 and May 2015 at the authors' institution. Postoperative radiation therapy was planned within 10 days following the stabilization in all cases. Clinical and radiological follow-up assessments were planned for 3 days, 3 weeks, 6 weeks, 3 months, 6 months, and 1 year after surgery. Outcome was assessed by means of standard postoperative evaluation and oncological and spinal quality of life measures (European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Version 3.0 [EORTC QLQ-C30] and Oswestry Disability Index [ODI], respectively). Moreover, 5 patients were given an activity monitoring device for recording the distance walked daily; preoperative and postoperative daily distances were compared. RESULTS Data from 17 cases were analyzed. There were no

  1. Selection of Fusion Levels Using the Fulcrum Bending Radiograph for the Management of Adolescent Idiopathic Scoliosis Patients with Alternate Level Pedicle Screw Strategy: Clinical Decision-making and Outcomes.

    Science.gov (United States)

    Samartzis, Dino; Leung, Yee; Shigematsu, Hideki; Natarajan, Deepa; Stokes, Oliver; Mak, Kin-Cheung; Yao, Guanfeng; Luk, Keith D K; Cheung, Kenneth M C

    2015-01-01

    Selecting fusion levels based on the Luk et al criteria for operative management of thoracic adolescent idiopathic scoliosis (AIS) with hook and hybrid systems yields acceptable curve correction and balance parameters; however, it is unknown whether utilizing a purely pedicle screw strategy is effective. Utilizing the fulcrum bending radiographic (FBR) to assess curve flexibility to select fusion levels, the following study assessed the efficacy of pedicle screw fixation with alternate level screw strategy (ALSS) for thoracic AIS. A retrospective study with prospective radiographic data collection/analyses (preoperative, postoperative 1-week and minimum 2-year follow-up) of 28 operative thoracic AIS patients undergoing ALSS was performed. Standing coronal/sagittal and FBR Cobb angles, FBR flexibility, fulcrum bending correction index (FBCI), trunkal shift, radiographic shoulder height (RSH), and list were assessed on x-rays. Fusion level selection was based on the Luk et al criteria and compared to conventional techniques. In the primary curve, the mean preoperative and postoperative 1 week and last follow-up standing coronal Cobb angles were 59.9, 17.2 and 20.0 degrees, respectively. Eighteen patients (64.3%) had distal levels saved (mean: 1.6 levels) in comparison to conventional techniques. Mean immediate and last follow-up FBCIs were 122.6% and 115.0%, respectively. Sagittal alignment did not statistically differ between any assessment intervals (p>0.05). A decrease in trunkal shift was noted from preoperative to last follow-up (p = 0.003). No statistically significant difference from preoperative to last follow-up was noted in RSH and list (p>0.05). No "add-on" of other vertebra or decompensation was noted and all patients achieved fusion. This is the first report to note that using the FBR for decision-making in selecting fusion levels in thoracic AIS patients undergoing management with pedicle screw constructs (e.g. ALSS) is a cost-effective strategy that

  2. Multiple-level lumbar spondylolysis and spondylolisthesis.

    Science.gov (United States)

    Liu, Xinyu; Wang, Lianlei; Yuan, Suomao; Tian, Yonghao; Zheng, Yanping; Li, Jianmin

    2015-03-01

    Lumbar spondylolysis and isthmic spondylolisthesis occur most commonly at only one spinal level. The authors report on 13 cases of lumbar spondylolysis with spondylolisthesis at multiple levels. During July 2007-March 2012, multiple-level spondylolysis associated with spondylolisthesis was diagnosed in 13 patients (10 male, 3 female) at Qilu Hospital of Shandong University. The mean patient age was 43.5 ± 14.6 years. The duration of low-back pain was 11.7 ± 5.1 months. Spondylolysis occurred at L-2 in 2 patients, L-3 in 4 patients, L-4 in all patients, and L-5 in 5 patients. Spondylolysis occurred at 3 spinal levels in 3 patients and at 2 levels in 10 patients. All patients had spondylolisthesis at 1 or 2 levels. Japanese Orthopaedic Association and visual analog scale scores were used to evaluate preoperative and postoperative neurological function and low-back pain. All patients underwent pedicle screw fixation and interbody fusion or direct pars interarticularis repair. Both low-back pain scores improved significantly after surgery (p spondylolysis and spondylolisthesis occurred more often in men. Most multiplelevel lumbar spondylolysis occurred at 2 spinal levels and was associated with sports, trauma, or heavy labor. Multiplelevel lumbar spondylolysis occurred mostly at L3-5; associated spondylolisthesis usually occurred at L-4 and L-5, mostly at L-4. The treatment principle was the same as that for single-level spondylolisthesis.

  3. Tophaceous gout causing lumbar stenosis: A case report.

    Science.gov (United States)

    Lu, Huigen; Sheng, Jianming; Dai, Jiaping; Hu, Xuqi

    2017-08-01

    Gout in the spine is very rare. The clinical symptoms of the spinal gout are various and lack of specificity. The authors report a case of spinal gout causing lumbar stenosis. We never find such wide-invasive spinal gouty lesion in the published studies. A 68-year-old male had low back pain radiating to bilateral lower limbs, accompanying with intermittent claudication that lasted for 3 months and aggravated 5 days ago. Spinal gout, lumbar stenosis. The patient underwent L2-L4 laminectomy, L2/3 L3/4 an d L4/5 discectomy and transforaminal lumbar interbody fusion with pedicle screw fixation. Dual-energy computed tomography detected extensive tophaceous deposits in L1/2 L2/3 L3/4 and L4/5 lumbar discs as well as the posterior column, especially L2-L3 and L4-L5 facet joints. During the surgery, we found a mass of chalky white material at the posterior column of L3 to L5 vertebral bodies, which also involved the intervertebral discs. Pathological examination confirmed the diagnosis of spinal gout. Although spinal gout is thought to be rare, the diagnosis should be considered if the patient had severe back pain and a history of gout. Dual-energy computed tomography is highly recommended for these patients.

  4. Internal fixation and muscle pedicle bone grafting in femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Gupta A

    2008-01-01

    Full Text Available Background: The treatment of displaced intracapsular femoral neck fracture is still an unsolved problem. Non-union and avascular necrosis are the two main complications of this fracture, especially if patient presents late. Muscle pedicle bone grafting has been advocated to provide additional blood supply. We present analysis of our 32 cases of displaced femoral neck fracture treated by internal fixation and quadratus femoris based muscle pedicle bone grafting. Materials and Methods: Open reduction and internal fixation with muscle pedicle grafting was done in 32 patients. The age of patients varied from 14-62 years (average age 45 years with male to female ratio of 13:3. Twenty-nine fractures were more than three weeks old. All the cases were treated by Meyers′ procedure. The fracture was internally fixed after open reduction and then a muscle pedicle graft was applied. It was supplemented by cancellous bone graft in seven cases. Fixation was done by parallel cancellous lag screws ( n = 19, crossed Garden′s screws ( n = 7, parallel Asnis screws ( n = 5 and Moore′s pin ( n = 1.Quadratus femoris muscle pedicle graft was used in 32 cases. In the initial 12 cases the graft was fixed with circumferential proline sutures, but later, to provide a secure fixation, the graft was fixed with a cancellous screw ( n = 20. Postoperative full weight bearing was deferred to an average of 10 weeks. Results: Union was achieved in 26/29 (89.65% cases which could be followed for an average period of 3.4 years, (2-8.5 years with good functional results and had the ability to squat and sit cross-legged. Results were based on hip rating system given by Salvatti and Wilson. The results were excellent in 15 cases, good in four cases, fair in four cases and poor in six cases. Complications were avascular necrosis ( n = 2, transient foot drop ( n = 2, coxa-vara ( n = 1 and temporary loss of scrotal sensation ( n = 1. Conclusion: Muscle pedicle bone grafting with

  5. Anterior debridement and fusion followed by posterior pedicle screw fixation in pyogenic spondylodiscitis: autologous iliac bone strut versus cage.

    Science.gov (United States)

    Pee, Yong Hun; Park, Jong Dae; Choi, Young-Geun; Lee, Sang-Ho

    2008-05-01

    An anterior approach for debridement and fusion with autologous bone graft has been recommended as the gold standard for surgical treatment of pyogenic spondylodiscitis. The use of anterior foreign body implants at the site of active infection is still a challenging procedure for spine surgeons. Several authors have recently introduced anterior grafting with titanium mesh cages instead of autologous bone strut in the treatment of spondylodiscitis. The authors present their experience of anterior fusion with 3 types of cages followed by posterior pedicle screw fixation. They also compare their results with the use of autologous iliac bone strut. The authors retrospectively reviewed the cases of 60 patients with pyogenic spondylodiscitis treated by anterior debridement between January 2003 and April 2005. Fusion using either cages or iliac bone struts was performed during the same course of anesthesia followed by posterior fixation. Twenty-three patients underwent fusion with autologous iliac bone strut, and 37 patients underwent fusion with 1 of the 3 types of cages. The infections resolved in all patients, as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. Patients in both groups were evaluated in terms of their preoperative and postoperative clinical and imaging findings. Single-stage anterior debridement and cage fusion followed by posterior pedicle screw fixation can be effective in the treatment of pyogenic spondylodiscitis. There was no difference in clinical and imaging outcomes between the strut group and cage group except for the subsidence rate. The subsidence rate was higher in the strut group than in the cage group. The duration until subsidence was also shorter in the strut group than in the cage group.

  6. Comparison of measurement results between cervical pedicle specimens and CT images

    International Nuclear Information System (INIS)

    Zhang Guangjian; Li Hua; Liu Haiyan; Gao Zhenping

    2011-01-01

    Objective: To compare the difference between the measurement results of the cervical pedicle specimens and CT image, and provide the basis for clinical cervical screw internal fixation operation. Methods: Twenty-seven Chinese adult cadaver cervical specimens including C3 to C7 vertebrae were measured by a digital calipers and CT image, containing pedicle height (PH, PH'), pedicle width(PW, PW'), total pedicle length (TL, TL') and two pedicle lengths(PL1, PL2; PL1', PL2'). The results of specimens and CT image were compared. Results: Different cervical vertebra in the same side of specimens or CT images, PW (PW'): C3, C4< C5, C6 (P<0.05), C5, C6< C7 (P<0.01); PH (PH'): there were no significant differences; TL, PL1, PL2 (TL', PL1', PL2'): there were no marked differences. In the same cervical vertebra of the specimens or CT images, PW (PW')< PH (PH') (P<0.01), PL1 (PL1') < PL2 (PL2') (P<0.01). Conclusion: The results of measurement by CT images are not markedly different from that of specimens. CT image measurement is available before cervical screw internal fixation operation. (authors)

  7. Lumbar spinal fusion. Outcome in relation to surgical methods, choice of implant and postoperative rehabilitation.

    Science.gov (United States)

    Christensen, Finn Bjarke

    2004-10-01

    Chronic low back pain (CLBP) has become one of the most common causes of disability in adults under 45 years of age and is consequently one of the most common reasons for early retirement in industrialised societies. Accordingly, CLBP represents an expensive drain on society's resources and is a very challenging area for which a consensus for rational therapy is yet to be established. The spinal fusion procedure was introduced as a treatment option for CLBP more than 70 years ago. However, few areas of spinal surgery have caused so much controversy as spinal fusion. The literature reveals divergent opinions about when fusion is indicated and how it should be performed. Furthermore, the significance of the role of postoperative rehabilitation following spinal fusion may be underestimated. There exists no consensus on the design of a program specific for rehabilitation. Ideally, for any given surgical procedure, it should be possible to identify not only possible complications relative to a surgical procedure, but also what symptoms may be expected, and what pain behaviour may be expected of a particular patient. The overall aims of the current studies were: 1) to introduce patient-based functional outcome evaluation into spinal fusion treatment; 2) to evaluate radiological assessment of different spinal fusion procedures; 3) to investigate the effect of titanium versus stainless steel pedicle screws on mechanical fixation and bone ingrowth in lumbar spinal fusion; 4) to analyse the clinical and radiological outcome of different lumbar spinal fusion techniques; 5) to evaluate complications and re-operation rates following different surgical procedures; and 6) to analyse the effect of different rehabilitation strategies for lumbar spinal fusion patients. The present thesis comprises 9 studies: 2 clinical retrospective studies, 1 clinical prospective case/reference study, 5 clinical randomised prospective studies and 1 animal study (Mini-pigs). In total, 594 patients

  8. Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis.

    Science.gov (United States)

    Dea, Nicolas; Fisher, Charles G; Batke, Juliet; Strelzow, Jason; Mendelsohn, Daniel; Paquette, Scott J; Kwon, Brian K; Boyd, Michael D; Dvorak, Marcel F S; Street, John T

    2016-01-01

    Pedicle screws are routinely used in contemporary spinal surgery. Screw misplacement may be asymptomatic but is also correlated with potential adverse events. Computer-assisted surgery (CAS) has been associated with improved screw placement accuracy rates. However, this technology has substantial acquisition and maintenance costs. Despite its increasing usage, no rigorous full economic evaluation comparing this technology to current standard of care has been reported. Medical costs are exploding in an unsustainable way. Health economic theory requires that medical equipment costs be compared with expected benefits. To answer this question for computer-assisted spinal surgery, we present an economic evaluation looking specifically at symptomatic misplaced screws leading to reoperation secondary to neurologic deficits or biomechanical concerns. The study design was an observational case-control study from prospectively collected data of consecutive patients treated with the aid of CAS (treatment group) compared with a matched historical cohort of patients treated with conventional fluoroscopy (control group). The patient sample consisted of consecutive patients treated surgically at a quaternary academic center. The primary effectiveness measure studied was the number of reoperations for misplaced screws within 1 year of the index surgery. Secondary outcome measures included were total adverse event rate and postoperative computed tomography usage for pedicle screw examination. A patient-level data cost-effectiveness analysis from the hospital perspective was conducted to determine the value of a navigation system coupled with intraoperative 3-D imaging (O-arm Imaging and the StealthStation S7 Navigation Systems, Medtronic, Louisville, CO, USA) in adult spinal surgery. The capital costs for both alternatives were reported as equivalent annual costs based on the annuitization of capital expenditures method using a 3% discount rate and a 7-year amortization period

  9. Biomechanical effect of interspinous process distraction height after lumbar fixation surgery: An in vitro model.

    Science.gov (United States)

    Fu, Lin; Ma, Jianxiong; Lu, Bin; Jia, Haobo; Zhao, Jie; Kuang, Mingjie; Feng, Rui; Xu, Liyan; Bai, Haohao; Sun, Lei; Wang, Ying; Ma, Xinlong

    2017-07-01

    Pedicle screw fixation may induce abnormal activity at adjacent segment and accelerate the degeneration of lumbar vertebrae. Dynamic stabilizers could provide an intermediate solution between conservative treatment and fusion surgery. Lumbar vertebral segment cephalad to instrumented fixation was the most common localization of adjacent segment degeneration. The aim of this study is to explore the use of interspinous process devices in the lumbar vertebral segment cephalad to fixation segment in changing the mechanical distribution and limiting abnormal activity of the spine. Eight specimens were tested in the following groups: intact group, instability group (bilateral facetectomy at L3-L4), fixation group (bilateral facetectomy and pedicle screw fixation at L3-L4), and hybrid fixation group (fixation at L3-L4 and simulating interspinous device implantation of 6, 8, 10, 12, 14, 16, and 18 mm at L2-L3). Range of motion, motion of vertebral body, and strain distribution change were recorded. The range of motion in extension with 16- and 18-mm hybrid constructs was significantly lower than intact, instability, and fixation groups. In flexion and lateral bending, the strain values of L4 inferior articular process with 18-mm hybrid construct have a significant difference compared with other groups. In axial rotation, under the condition of a contralateral state, the strain values of L2 superior articular process with 18-mm hybrid construct have a significant difference compared with intact and fixation groups. The strain value of the L4 inferior articular process had negative correlation with height distraction in three dimensions, except extension. A negative correlation between the strain value of the L2 superior articular process and distraction height was found in contralateral bending and contralateral axial rotation. Interspinous process devices above the fixation segment can change the mechanical distribution of the spine and limit activity in some of the

  10. Minimally Invasive Transforaminal Lumbar Interbody Fusion and Unilateral Fixation for Degenerative Lumbar Disease.

    Science.gov (United States)

    Wang, Hui-Wang; Hu, Yong-Cheng; Wu, Zhan-Yong; Wu, Hua-Rong; Wu, Chun-Fu; Zhang, Lian-Suo; Xu, Wei-Kun; Fan, Hui-Long; Cai, Jin-Sheng; Ma, Jian-Qing

    2017-08-01

    To evaluate the clinical effect of the minimally invasive transforaminal lumbar interbody fusion combined with posterolateral fusion and unilateral fixation using a tubular retractor in the management of degenerative lumbar disease. A retrospective analysis was conducted to analyze the clinical outcome of 58 degenerative lumbar disease patients who were treated with minimally invasive transforaminal lumbar interbody fusion combined with posterolateral fusion and unilateral fixation during December 2012 to January 2015. The spine was unilaterally approached through a 3.0-cm skin incision centered on the disc space, located 2.5 cm lateral to the midline, and the multifidus muscles and longissimus dorsi were stripped off. After transforaminal lumbar interbody fusion and posterolateral fusion the unilateral pedicle screw fixation was performed. The visual analogue scale (VAS) for back and leg pain, the Oswestry disability index (ODI), and the MacNab score were applied to evaluate clinical effects. The operation time, peri-operative bleeding, postoperative time in bed, hospitalization costs, and the change in the intervertebral height were analyzed. Radiological fusion based on the Bridwell grading system was also assessed at the last follow-up. The quality of life of the patients before and after the operation was assessed using the short form-36 scale (SF-36). Fifty-eight operations were successfully performed, and no nerve root injury or dural tear occurred. The average operation time was 138 ± 33 min, intraoperative blood loss was 126 ± 50 mL, the duration from surgery to getting out of bed was 46 ± 8 h, and hospitalization cost was 1.6 ± 0.2 ten thousand yuan. All of the 58 patients were followed up for 7-31 months, with an average of 14.6 months. The postoperative VAS scores and ODI score were significantly improved compared with preoperative data (P degenerative lumbar disease, and the short-term clinical outcome is satisfactory

  11. Pedicle screws with a thin hydroxyapatite coating for improving fixation at the bone-implant interface in the osteoporotic spine: experimental study in a porcine model.

    Science.gov (United States)

    Ohe, Makoto; Moridaira, Hiroshi; Inami, Satoshi; Takeuchi, Daisaku; Nohara, Yutaka; Taneichi, Hiroshi

    2018-03-30

    OBJECTIVE Instrumentation failure caused by the loosening of pedicle screws (PSs) in patients with osteoporosis is a serious problem after spinal surgery. The addition of a thin hydroxyapatite (HA) surface coating applied by using a sputtering process was reported recently to be a promising method for providing bone conduction around an implant without a significant risk of coating-layer breakage. In this study, the authors evaluated the biomechanical and histological features of the bone-implant interface (BII) of PSs with a thin HA coating in an in vivo porcine osteoporotic spine model. METHODS Three types of PSs (untreated/standard [STPS], sandblasted [BLPS], and HA-coated [HAPS] PSs) were implanted into the thoracic and lumbar spine (T9-L6) of 8 mature Clawn miniature pigs (6 ovariectomized [osteoporosis group] and 2 sham-operated [control group] pigs). The spines were harvested from the osteoporosis group at 0, 2, 4, 8, 12, or 24 weeks after PS placement and from the control group at 0 or 24 weeks. Their bone mineral density (BMD) was measured by peripheral quantitative CT. Histological evaluation of the BIIs was conducted by performing bone volume/tissue volume and bone surface/implant surface measurements. The strength of the BII was evaluated with extraction torque testing. RESULTS The BMD decreased significantly in the osteoporosis group (p < 0.01). HAPSs exhibited the greatest mean extraction peak torque at 8 weeks, and HAPSs and BLPSs exhibited significantly greater mean torque than the STPSs at 12 weeks (p < 0.05). The bone surface/implant surface ratio was significantly higher for HAPSs than for STPSs after 2 weeks (p < 0.05), and bonding between bone and the implant surface was maintained until 24 weeks with no detachment of the coating layer. In contrast, the bone volume/tissue volume ratio was significantly higher for HAPSs than for BLPSs or STPSs only at 4 weeks. CONCLUSIONS Using PSs with a thin HA coating applied using a sputtering process

  12. Simulated lumbar minimally invasive surgery educational model with didactic and technical components.

    Science.gov (United States)

    Chitale, Rohan; Ghobrial, George M; Lobel, Darlene; Harrop, James

    2013-10-01

    The learning and development of technical skills are paramount for neurosurgical trainees. External influences and a need for maximizing efficiency and proficiency have encouraged advancements in simulator-based learning models. To confirm the importance of establishing an educational curriculum for teaching minimally invasive techniques of pedicle screw placement using a computer-enhanced physical model of percutaneous pedicle screw placement with simultaneous didactic and technical components. A 2-hour educational curriculum was created to educate neurosurgical residents on anatomy, pathophysiology, and technical aspects associated with image-guided pedicle screw placement. Predidactic and postdidactic practical and written scores were analyzed and compared. Scores were calculated for each participant on the basis of the optimal pedicle screw starting point and trajectory for both fluoroscopy and computed tomographic navigation. Eight trainees participated in this module. Average mean scores on the written didactic test improved from 78% to 100%. The technical component scores for fluoroscopic guidance improved from 58.8 to 52.9. Technical score for computed tomography-navigated guidance also improved from 28.3 to 26.6. Didactic and technical quantitative scores with a simulator-based educational curriculum improved objectively measured resident performance. A minimally invasive spine simulation model and curriculum may serve a valuable function in the education of neurosurgical residents and outcomes for patients.

  13. A study on a pedicle-screw-based reduction method for artificially reduced artifacts

    Science.gov (United States)

    Kim, Hyun-Ju; Lee, Hae-Kag; Cho, Jae-Hwan

    2017-09-01

    The purpose of this study is a quantitative analysis of the degree of the reduction of the artifacts that are induced by pedicle screws through the application of the recently developed iterative metallic artifact reduction (I MAR) software. Screw-type implants that are composed of 4.5 g/cm3 titanium (Ti) with an approximate average computed tomography (CT) value of 6500 Hounsfield units (HUs) that are used for the treatment of spinal diseases were placed in paraffin, a tissueequivalent material, and then dried. After the insertion, the scanning conditions were fixed as 120 kVp and 250 mA using multidetector computed tomography (MDCT) (Enlarge, Siemens, Germany). The slice thickness and the increment were set at the fields of view (FOVs) of 3 mm and 120 mm, respectively; the pitch is 0.8; the rotation time is 1 s; and the I MAR software was applied to the raw data of the acquired images to compare the CT-value changes of the posterior images. When the I MAR software was applied to animal vertebrae, it was possible to reduce the 65.7% image loss of the black-hole-effect image through the application of the I MAR software. When the I MAR image loss (%) was compared with the white-streak-effect image, the high-intensity image type with the white-streak effect could be reduced by 91.34% through the application of the I MAR software. In conclusion, a metal artifact that is due to a high-density material can be reduced more effectively when the I MAR algorithm is applied compared with that from the application of the conventional MAR algorithm. The I MAR can provide information on the various tissues that form around the artifact and the reduced metal structures, which can be helpful for radiologists and clinicians in their determination of an accurate diagnosis.

  14. Biomechanical Analysis of an Expandable Lumbar Interbody Spacer.

    Science.gov (United States)

    Soriano-Baron, Hector; Newcomb, Anna G U S; Malhotra, Devika; Palma, Atilio E; Martinez-Del-Campo, Eduardo; Crawford, Neil R; Theodore, Nicholas; Kelly, Brian P; Kaibara, Taro

    2018-06-01

    Recently developed expandable interbody spacers are widely accepted in spinal surgery; however, the resulting biomechanical effects of their use have not yet been fully studied. We analyzed the biomechanical effects of an expandable polyetheretherketone interbody spacer inserted through a bilateral posterior approach with and without different modalities of posterior augmentation. Biomechanical nondestructive flexibility testing was performed in 7 human cadaveric lumbar (L2-L5) specimens followed by axial compressive loading. Each specimen was tested under 6 conditions: 1) intact, 2) bilateral L3-L4 cortical screw/rod (CSR) alone, 3) WaveD alone, 4) WaveD + CSR, 5) WaveD + bilateral L3-L4 pedicle screw/rod (PSR), and 6) WaveD + CSR/PSR, where CSR/PSR was a hybrid construct comprising bilateral cortical-level L3 and pedicle-level L4 screws interconnected by rods. The range of motion (ROM) with the interbody spacer alone decreased significantly compared with the intact condition during flexion-extension (P = 0.02) but not during lateral bending or axial rotation (P ≥ 0.19). The addition of CSR or PSR to the interbody spacer alone condition significantly decreased the ROM compared with the interbody spacer alone (P ≤ 0.002); and WaveD + CSR, WaveD + PSR, and WaveD + CSR/PSR (hybrid) (P ≥ 0.29) did not differ. The axial compressive stiffness (resistance to change in foraminal height during compressive loading) with the interbody spacer alone did not differ from the intact condition (P = 0.96), whereas WaveD + posterior instrumentation significantly increased compressive stiffness compared with the intact condition and the interbody spacer alone (P ≤ 0.001). The WaveD alone significantly reduced ROM during flexion-extension while maintaining the axial compressive stiffness. CSR, PSR, and CSR/PSR hybrid constructs were all effective in augmenting the expandable interbody spacer system and improving its stability. Copyright © 2018 Elsevier Inc. All

  15. Biomechanics of Posterior Dynamic Fusion Systems in the Lumbar Spine: Implications for Stabilization With Improved Arthrodesis.

    Science.gov (United States)

    Yu, Alexander K; Siegfried, Catherine M; Chew, Brandon; Hobbs, Joseph; Sabersky, Abraham; Jho, Diana J; Cook, Daniel J; Bellotte, Jonathan Brad; Whiting, Donald M; Cheng, Boyle C

    2016-08-01

    A comparative biomechanical human cadaveric spine study of a dynamic fusion rod and a traditional titanium rod. The purpose of this study was to measure and compare the biomechanical metrics associated with a dynamic fusion device, Isobar TTL Evolution, and a rigid rod. Dynamic fusion rods may enhance arthrodesis compared with a rigid rod. Wolff's law implies that bone remodeling and growth may be enhanced through anterior column loading (AL). This is important for dynamic fusion rods because their purpose is to increase AL. Six fresh-frozen lumbar cadaveric specimens were used. Each untreated specimen (Intact) underwent biomechanical testing. Next, each specimen had a unilateral transforaminal lumbar interbody fusion performed at L3-L4 using a cage with an integrated load cell. Pedicle screws were also placed at this time. Subsequently, the Isobar was implanted and tested, and finally, a rigid rod replaced the Isobar in the same pedicle screw arrangement. In terms of range of motion, the Isobar performed comparably to the rigid rod and there was no statistical difference found between Isobar and rigid rod. There was a significant difference between the intact and rigid rod and also between intact and Isobar conditions in flexion extension. For interpedicular displacement, there was a significant increase in flexion extension (P=0.017) for the Isobar compared with the rigid rod. Isobar showed increased AL under axial compression compared with the rigid rod (P=0.024). Isobar provided comparable stabilization to a rigid rod when using range of motion as the metric, however, AL was increased because of the greater interpedicular displacement of dynamic rod compared with a rigid rod. By increasing interpedicular displacement and AL, it potentially brings clinical benefit to procedures relying on arthrodesis.

  16. Lumbar Lordosis Minus Thoracic Kyphosis: Remain Constant in Adolescent Idiopathic Scoliosis Patients Before and After Correction Surgery.

    Science.gov (United States)

    Yang, Mingyuan; Yang, Changwei; Chen, Ziqiang; Wei, Xianzhao; Chen, Yuanyuan; Zhao, Jian; Shao, Jie; Zhu, Xiaodong; Li, Ming

    2016-03-01

    A retrospective study. To explore the relationship between the change of lumbar lordosis (LL) and thoracic kyphosis (TK) in AIS patients after correction surgery. TK tends to decrease in Lenke 1 and Lenke 2 AIS patients after correction surgery using pedicle screws, with the compensation of LL decrease. We hypothesize that lumbar lordosis minus thoracic kyphosis (LL-TK) remains constant after correction surgery to achieve the sagittal balance in AIS patients. Medical records of Lenke 1 or Lenke 2 AIS patients who received posterior correction surgery using pedicle screws in our hospital from January 2010 to January 2013 were reviewed. General characters of patients and radiological parameters were evaluated before the surgery and at two years' follow-up. Correlation analysis between TK and LL was conducted. LL-TK and the change of LL and TK were analyzed at preoperation and final follow-up. A total of 76 Lenke 1 and Lenke 2 AIS patients were included. Both TK and LL decreased significantly after correction surgery (P = 0.019 and P = 0.040, respectively). There were significant correlations between TK and LL before and after surgery, respectively (preoperative: r = 0.234, P = 0.042; postoperative: r = 0.310, P = 0.006). Preoperative and postoperative LL-TK was 23.80° and 25.09°, respectively, and no significant difference of LL-TK was observed (P = 0.372). The same tendency was observed in the change of LL and TK, and significant correlation was also found between the change of TK and LL (r = 0.626, P = 0.002). The same change of LL and TK and no significant difference in LL-TK indicated that LL-TK might be an important compensatory mechanism in keeping sagittal balance.

  17. Tratamento da instabilidade lombar com parafusos pediculares Treatment of lumbar instability with pedicular screws

    Directory of Open Access Journals (Sweden)

    Osmar Avanzi

    2005-01-01

    Full Text Available A instabilidade lombar é uma doença freqüente na prática clínica. Vários autores preconizam o uso de parafusos pediculares para fixação da artrodese posterior, demonstrando melhores resultados do que a estabilização in situ. OBJETIVO: Avaliar o resultado funcional e radiográfico dos pacientes que procuraram o Grupo de Coluna da Faculdade de Ciências Médicas da Santa Casa de São Paulo portadores de instabilidade lombar submetidos ao tratamento cirúrgico pela artrodese vertebral por via posterior utilizando-se fixação metálica representada por parafusos pediculares. MÉTODOS: Foram coletados dados dos prontuários médicos do Serviço de Arquivos Médicos (S.A.M.E da Irmandade da Santa Casa de Misericórdia de São Paulo e avaliação por meio de radiografias simples nas incidências frente, perfil e oblíquas para estudos de imagem além da avaliação funcional pré e pós-operatória, com seguimento mínimo de dois anos. RESULTADOS: Durante o período de Novembro de 1995 à Junho de 2000 avaliamos dez pacientes portadores de instabilidade lombar degenerativa (48%, cinco pacientes com espondilolistese ístmica (23% e seis com estenose lombar degenerativa (29%. Quanto à avaliação funcional, obtivemos 76% de resultados excelentes e bons. As complicações verificadas foram infecção superficial, pseudartrose e posicionamento inadequado dos parafusos (19%. CONCLUSÕES: Os autores concluem que este método de fixação é eficaz, apresentando fusão da artrodese em 95% dos pacientes.The lumbar instability is a common desease in clinical practice. Several authors recommend the use of pedicular screws as a fixation system for posterior arthodesis since they provide better results compared to in situ stabilization. Objective: to evaluate the functional and radiographic results in patients assisted by the Spine Group of the Medical Sciences School of Santa Casa of São Paulo, presenting lumbar instability and who underwent

  18. Sacroiliac joint luxation after pedicle subtraction osteotomy: report of two cases and analysis of failure mechanism.

    Science.gov (United States)

    Charles, Yann Philippe; Yu, Bo; Steib, Jean-Paul

    2016-05-01

    Sagittal decompensation after pedicle subtraction osteotomy (PSO) is considered as late onset complication. Several mechanisms have been suggested, but little attention has been paid to the caudal end of lumbar instrumented fusion, especially sacral iliac joint (SIJ) deterioration. Clinical histories and radiographic sagittal parameters of two patients with SIJ luxation after PSO are presented. The biomechanical failure mechanism and risk factors are analysed. Two patients underwent correction of fixed anterior sagittal imbalance by PSO, followed by pseudarthrosis revision surgery. Both of them sustained persistent sacroiliac pain, progressive recurrence of anterior imbalance and progressive pelvic incidence (PI) increase around 10°. An acute bilateral SIJ luxation occurred in both patients leading to sharp increase or PI around 20°. One patient was treated by SIJ fusion and the other patient was placed on non-weight-bearing crutch ambulation for 1 year. Both patients had a high preoperative PI (95° and 78°). A theoretical match between lumbar lordosis (LL) and PI was not achieved by PSO. Osteopenia was present in both patients. Computed tomography evidenced L5-S1 pseudarthrosis and sacroiliac joint violation by pelvic or sacral ala screws. Patients with high PI might seek for further compensation at their SIJ when lacking LL after PSO. Chronic anterior imbalance might lead to progressive weakening of sacroiliac ligaments. Initial circumferential lumbosacral fusion and accurate iliac screw fixation might reduce stress on implants, risk for pseudarthrosis, implant failure and finally SIJ deterioration. Bone mineral density should further be investigated preoperatively.

  19. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory.

    Science.gov (United States)

    Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J

    2014-02-01

    Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.

  20. Comparison of multiple linear regression and artificial neural network in developing the objective functions of the orthopaedic screws.

    Science.gov (United States)

    Hsu, Ching-Chi; Lin, Jinn; Chao, Ching-Kong

    2011-12-01

    Optimizing the orthopaedic screws can greatly improve their biomechanical performances. However, a methodical design optimization approach requires a long time to search the best design. Thus, the surrogate objective functions of the orthopaedic screws should be accurately developed. To our knowledge, there is no study to evaluate the strengths and limitations of the surrogate methods in developing the objective functions of the orthopaedic screws. Three-dimensional finite element models for both the tibial locking screws and the spinal pedicle screws were constructed and analyzed. Then, the learning data were prepared according to the arrangement of the Taguchi orthogonal array, and the verification data were selected with use of a randomized selection. Finally, the surrogate objective functions were developed by using either the multiple linear regression or the artificial neural network. The applicability and accuracy of those surrogate methods were evaluated and discussed. The multiple linear regression method could successfully construct the objective function of the tibial locking screws, but it failed to develop the objective function of the spinal pedicle screws. The artificial neural network method showed a greater capacity of prediction in developing the objective functions for the tibial locking screws and the spinal pedicle screws than the multiple linear regression method. The artificial neural network method may be a useful option for developing the objective functions of the orthopaedic screws with a greater structural complexity. The surrogate objective functions of the orthopaedic screws could effectively decrease the time and effort required for the design optimization process. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Can experimental data in humans verify the finite element-based bone remodeling algorithm?

    DEFF Research Database (Denmark)

    Wong, C.; Gehrchen, P.M.; Kiaer, T.

    2008-01-01

    STUDY DESIGN: A finite element analysis-based bone remodeling study in human was conducted in the lumbar spine operated on with pedicle screws. Bone remodeling results were compared to prospective experimental bone mineral content data of patients operated on with pedicle screws. OBJECTIVE......: The validity of 2 bone remodeling algorithms was evaluated by comparing against prospective bone mineral content measurements. Also, the potential stress shielding effect was examined using the 2 bone remodeling algorithms and the experimental bone mineral data. SUMMARY OF BACKGROUND DATA: In previous studies...... operated on with pedicle screws between L4 and L5. The stress shielding effect was also examined. The bone remodeling results were compared with prospective bone mineral content measurements of 4 patients. They were measured after surgery, 3-, 6- and 12-months postoperatively. RESULTS: After 1 year...

  2. Unilateral Pedicle Stress Fracture in a Long-Term Hemodialysis Patient with Isthmic Spondylolisthesis

    Directory of Open Access Journals (Sweden)

    Keishi Maruo

    2015-01-01

    Full Text Available Most unilateral pedicle stress fractures occur on the contralateral side of patients with unilateral spondylolysis. However, there are few reports of unilateral pedicle stress fractures in patients with bilateral spondylolysis and spondylolisthesis. We report a unique case of unilateral pedicle stress fracture in a long-term hemodialysis patient with isthmic spondylolisthesis. A 65-year-old man who had undergone hemodialysis presented with lower back pain that had persisted for several years. The patient experienced severe right lower extremity pain with no history of trauma. Computed tomography revealed unilateral pedicle fracture with bilateral L5 spondylolysis and spondylolisthesis with progression of scoliosis. The patient underwent Gill laminectomy of L5 with pedicle screw fixation at L4-S1 and interbody fusion at L5-S1. The patient’s leg pain ceased immediately, and he began walking without leg pain. In our present patient, development of scoliosis caused by destructive spondyloarthropathy may have contributed to a unilateral pedicle fracture.

  3. Polyetheretherketone (PEEK) Rods in Lumbar Spine Degenerative Disease: A Case Series.

    Science.gov (United States)

    Ormond, D Ryan; Albert, Ladislau; Das, Kaushik

    2016-08-01

    Retrospective case series. The purpose of our study was to retrospectively review the results of posterior lumbar fusion using polyetheretherketone (PEEK) rods. Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the lumbar spine for degenerative disease. Rigid fixation with titanium rods leads to high fusion rates, but may also contribute to stress shielding and adjacent segment degeneration (ASD). Thus, some have advocated using semirigid rods made of PEEK. Although the biomechanical properties of PEEK rods have shown improved stress-shielding characteristics and anterior load-sharing properties, there are very few clinical studies evaluating their application in the lumbar spine. We evaluated a retrospective cohort of 42 patients who underwent posterior lumbar fusion from 2007 to 2009 for the treatment of lumbar spine degenerative disease using PEEK rods. Reoperation rate was the primary outcome evaluated. Fusion rate was also evaluated. Eight of the 42 patients with PEEK rods required reoperation. Reasons for reoperation mainly included ASD (5/8) and nonunion with cage migration (3/8). Radiographically, documented fusion rate was 86%. Mean follow-up was 31.4 months. No statistical differences were found in fusion rates or reoperation between age above 55 years and younger than 55 years (P=1.00), male and female (P=0.110), single or multilevel fusion (P=0.67), and fusion with and without an interbody graft (P=0.69). Smokers showed a trend towards increased risk of reoperation for ASD or instrumentation failure (P=0.056). PEEK rods demonstrate a similar fusion and reoperation rate in comparison to other instrumentation modalities in the treatment of degenerative lumbar spine disease.

  4. Short term outcome of posterior dynamic stabilization system in degenerative lumbar diseases.

    Science.gov (United States)

    Yang, Mingyuan; Li, Chao; Chen, Ziqiang; Bai, Yushu; Li, Ming

    2014-11-01

    Decompression and fusion is considered as the 'gold standard' for the treatment of degenerative lumbar diseases, however, many disadvantages have been reported in several studies, recently like donor site pain, pseudoarthrosis, nonunion, screw loosening, instrumentation failure, infection, adjacent segment disease (ASDis) and degeneration. Dynamic neutralization system (Dynesys) avoids many of these disadvantages. This system is made up of pedicle screws, polyethylene terephthalate cords, and polycarbonate urethane spacers to stabilize the functional spinal unit and preserve the adjacent motion after surgeries. This was a retrospective cohort study to compare the effect of Dynesys for treating degenerative lumbar diseases with posterior lumbar interbody fusion (PLIF) based on short term followup. Seventy five consecutive patients of lumbar degenerative disease operated between October 2010 and November 2012 were studied with a minimum followup of 2 years. Patients were divided into two groups according to the different surgeries. 30 patients underwent decompression and implantation of Dynesys in two levels (n = 29) or three levels (n = 1) and 45 patients underwent PLIF in two levels (n = 39) or three levels (n = 6). Clinical and radiographic outcomes between two groups were reviewed. Thirty patients (male:17, female:13) with a mean age of 55.96 ± 7.68 years were included in Dynesys group and the PLIF group included 45 patients (male:21, female:24) with a mean age of 54.69 ± 3.26 years. The average followup in Dynesys group and PLIF group was 2.22 ± 0.43 year (range 2-3.5 year) and 2.17 ± 0.76 year (range 2-3 year), respectively. Dynesys group showed a shorter operation time (141.06 ± 11.36 min vs. 176.98 ± 6.72 min, P degenerative disease showed clinical benefits with motion preservation of the operated segments, but does not have the significant advantage on motion preservation at adjacent segments, to avoid the degeneration of adjacent intervertebral disk.

  5. Surgical treatment in lumbar spondylolisthesis: experience with 45 patients

    International Nuclear Information System (INIS)

    Pasha, I.; Haider, I.Z.; Qureshi, M.A.; Malik, A.S.

    2012-01-01

    Background: Spondylolithesis is forward slipping of upper vertebra in relation to its lower one, which at times requires surgery. The objective of present study is to document the outcome of surgical treatment in spondylolisthesis of lumbosacral region. Methods: We reviewed outcome of surgery in 45 patients with spondylolisthesis. Improvement in pain intensity, neurological status and union achieved after surgery was studied. All patients requiring surgical treatment were included in the study. The patients were operated by single spine surgeon. A proforma was made for each patient and records were kept in a custom built Microsoft access database. Results: Majority of our patient were in 4th and 5th decade with some male domination. Pain was main indication for surgery which was excruciating in 6, severe in 33, and moderate in 6 cases. The neurological status was normal in 34 cases while 11 patients had some deficit. L5-S1 was affected in 26, L4-L5 in 13 and multi or high level was found in rest of cases. Slip grade was measured with Meyerding grades, 18 had grade II, 15 had I, 9 had III and 3 had IV spondylolisthesis. Posterior lumbar inter body fusion (PLIF) was done in 24 patients, posterolateral, transforaminal lumbar inter body and anterior inter body fusion in others. Translaminar screw fixation, transpedicular transdiscal transcorporial and Delta fixation in some cases. Pedicle screw fixation was done in most cases, AO fixator internae and 4.5 mm screw in others. Average follow up was 2 years and 5 months, max 5 years and minimum 6 months. Pain relief was achieved in 82%, neurological improvement 60% and union in 91% cases. There was no deterioration of neurological status, two implant failure and one wound infection. Conclusion: Surgical procedure for Spondylolisthesis must be individualised. Young patients with spondylolysis can be treated with osteosynthesis and sparing of motion segment. PLIF provides satisfactory results in majority of low to moderate

  6. A pilot study of the utility of a laboratory-based spinal fixation training program for neurosurgical residents.

    Science.gov (United States)

    Sundar, Swetha J; Healy, Andrew T; Kshettry, Varun R; Mroz, Thomas E; Schlenk, Richard; Benzel, Edward C

    2016-05-01

    OBJECTIVE Pedicle and lateral mass screw placement is technically demanding due to complex 3D spinal anatomy that is not easily visualized. Neurosurgical and orthopedic surgery residents must be properly trained in such procedures, which can be associated with significant complications and associated morbidity. Current training in pedicle and lateral mass screw placement involves didactic teaching and supervised placement in the operating room. The objective of this study was to assess whether teaching residents to place pedicle and lateral mass screws using navigation software, combined with practice using cadaveric specimens and Sawbones models, would improve screw placement accuracy. METHODS This was a single-blinded, prospective, randomized pilot study with 8 junior neurosurgical residents and 2 senior medical students with prior neurosurgery exposure. Both the study group and the level of training-matched control group (each group with 4 level of training-matched residents and 1 senior medical student) were exposed to a standardized didactic education regarding spinal anatomy and screw placement techniques. The study group was exposed to an additional pilot program that included a training session using navigation software combined with cadaveric specimens and accessibility to Sawbones models. RESULTS A statistically significant reduction in overall surgical error was observed in the study group compared with the control group (p = 0.04). Analysis by spinal region demonstrated a significant reduction in surgical error in the thoracic and lumbar regions in the study group compared with controls (p = 0.02 and p = 0.04, respectively). The study group also was observed to place screws more optimally in the cervical, thoracic, and lumbar regions (p = 0.02, p = 0.04, and p = 0.04, respectively). CONCLUSIONS Surgical resident education in pedicle and lateral mass screw placement is a priority for training programs. This study demonstrated that compared with a

  7. Unconventional fixation Thoracolumbar fractures using round hole boneplates and transpedicular screws

    International Nuclear Information System (INIS)

    Behairy, Yaser M.

    2001-01-01

    In an attempt to contain the high cost of commercially available pediclescrew systems, several authors have used unconventional alternatives such aslocally made plates or dynamic compression plates (DCP) along with cancellousscrews for transpedicular fixation of the thoracolumbar spine. These plates,however, allow for a wide range of motion at the plate-screw interphase andthe construct does not provide stability in the sagittal plane. Round holebone plates, on the other hand, allow much less mobility at the plate-screwinterphase and the final construct offers better stability in the sagittalplane. Our objective was to determine the clinical, radiologic and functionalstatus of patients who underwent posterior fracture fixation using round holebone plates and cancellous screws and evaluate the construct's ability tomaintain reduction of the fracture. This was a postoperative follow-up ofpatients with fractures around the thoracolumbar junction fixed using roundhole bone plates and cancellous transpedicular screws. Round hole bone platesalong with 6.5 mm transpedicular cancellous screws were used for posteriorspinal instrumentation in neurologically intact patients with isolatedunstable fractures of the last thoracic or first lumbar vertebra. Seventeenpatients were included in this study. There mean follow-up was 10 months(range 5 to 12). All had evidence of fusion at a mean of 5 months (range 4 to7). No patients had breakage or loosening of the screws and none had breakageof the plate. The mean kyphosis angle at the fracture site was 34 degreepreoperatively, -4 degree in the immediate postoperative period, and 3 degreeon final follow-up radiographs. The percentage loss of anterior vertebralbody height was 51% in the immediate postoperative period and 16% on finalfollow-up radiographs. The use of round hole bone plates along with 6.5 mmcancellous screws inserted into the pedicles provides an angle-stableconstruct that allows for better stability in the sagittal plane

  8. Pneumomediastinum, Subcutaneous Emphysema, and Tracheal Tear in the Early Postoperative Period of Spinal Surgery in a Paraplegic Achondroplastic Dwarf

    Directory of Open Access Journals (Sweden)

    Sinan Kahraman

    2013-01-01

    Full Text Available Achondroplasia was first described in 1878 and is the most common form of human skeletal dysplasia. Spinal manifestations include thoracolumbar kyphosis, foramen magnum, and spinal stenosis. Progressive kyphosis can result in spinal cord compression and paraplegia due to the reduced size of spinal canal. The deficits are typically progressive, presenting as an insidious onset of paresthesia, followed by the inability to walk and then by urinary incontinence. Paraplegia can be the result of direct pressure on the cord by bone or the injury to the anterior spinal vessels by a protruding bone. Surgical treatment consists of posterior instrumentation, fusion with total wide laminectomy at stenosis levels, and anterior interbody support. Pedicle screws are preferred for spinal instrumentation because wires and hooks may induce spinal cord injury due to the narrow spinal canal. Pedicle lengths are significantly shorter, and 20–25 mm long screws are appropriate for lower thoracic and lumbar pedicles in adult achondroplastic There is no information about the appropriate length of screws for the upper thoracic pedicles. Tracheal injury due to inappropriate pedicle screw length is a rare complication. We report an extremely rare case of tracheal tear due to posterior instrumentation and its management in the early postoperative period.

  9. What is the Difference in Morphologic Features of the Thoracic Pedicle Between Patients With Adolescent Idiopathic Scoliosis and Healthy Subjects? A CT-based Case-control Study.

    Science.gov (United States)

    Gao, Bo; Gao, Wenjie; Chen, Chong; Wang, Qinghua; Lin, Shaochun; Xu, Caixia; Huang, Dongsheng; Su, Peiqiang

    2017-11-01

    Describing the morphologic features of the thoracic pedicle in patients with adolescent idiopathic scoliosis is necessary for placement of pedicle screws. Previous studies showed inadequate reliability owing to small sample size and heterogeneity of the patients surveyed. To use CT scans (1) to describe the morphologic features of 2718 thoracic pedicles from 60 female patients with Lenke Type 1 adolescent idiopathic scoliosis and 60 age-, sex-, and height-matched controls; and (2) to classify the pedicles in three types based on pedicle width and analyze the distribution of each type. A total of 2718 pedicles from 60 female patients with Lenke Type 1 adolescent idiopathic scoliosis and 60 matched female controls were analyzed via CT. All patients surveyed were diagnosed with adolescent idiopathic scoliosis, Lenke Type 1, at the First Affiliated Hospital of Sun Yat-sen University, and all underwent pedicle screw fixation between January 2008 and December 2013 with preoperative radiographs and CT images on file. We routinely obtained CT scans before these procedures; all patients who underwent surgery during that period had CT scans, and all were available for analysis here. Control subjects had CT scans for other clinical indications and had no abnormal findings of the spine. The control subjects were chosen to match patients in terms of age (15 ± 2.6 years versus 15 ± 2.6 years) and sex. Height of the two groups also was matched (154 ± 9 cm versus 155 ± 10 cm; mean difference, -1.06 cm; 95% CI, -1.24 to -0.81 cm; p adolescent idiopathic scoliosis (22%; 293 of 1322) compared with controls (13%; 178 of 1396) (odds ratio [OR] = 0.51; 95% CI, 0.42-0.63; p adolescent idiopathic scoliosis, they commonly occurred on the concave side 34% (228 of 661) and on the AV-SC region (32%; 43 of 136). Pedicle width on the concave side was narrower than pedicle width on the convex side and pedicle width in healthy control subjects. The apical vertebra in the structural curve was

  10. Axial lumbar interbody fusion: a 6-year single-center experience

    Directory of Open Access Journals (Sweden)

    Zeilstra DJ

    2013-08-01

    Full Text Available Dick J Zeilstra,1 Larry E Miller,2,3 Jon E Block3 1Bergman Clinics, Naarden and NedSpine, Ede, The Netherlands; 2Miller Scientific Consulting, Inc, Arden, NC, USA; 3The Jon Block Group, San Francisco, CA, USA Introduction: The aim of this study is to report our 6-year single-center experience with L5–S1 axial lumbar interbody fusion (AxiaLIF. Methods: A total of 131 patients with symptomatic degenerative disc disease refractory to nonsurgical treatment were treated with AxiaLIF at L5–S1, and were followed for a minimum of 1 year (mean: 21 months. Main outcomes included back and leg pain severity, Oswestry Disability Index score, working status, analgesic medication use, patient satisfaction, and complications. Computed tomography was used to determine postoperative fusion status. Results: No intraoperative complications, including vascular, neural, urologic, or bowel injuries, were reported. Back and leg pain severity decreased by 51% and 42%, respectively, during the follow-up period (both P < 0.001. Back function scores improved 50% compared to baseline. Clinical success, defined as improvement ≥30%, was 67% for back pain severity, 65% for leg pain severity, and 71% for back function. The employment rate increased from 47% before surgery to 64% at final follow-up (P < 0.001. Less than one in four patients regularly used analgesic medications postsurgery. Patient satisfaction with the AxiaLIF procedure was 83%. The fusion rate was 87.8% at final follow-up. During follow-up, 17 (13.0% patients underwent 18 reoperations on the lumbar spine, including pedicle screw fixation (n = 10, total disc replacement of an uninvolved level (n = 3, facet screw fixation (n = 3, facet screw removal (n = 1, and interbody fusion at L4–L5 (n = 1. Eight (6.1% reoperations were at the index level. Conclusion: Single-level AxiaLIF is a safe and effective means to achieve lumbosacral fusion in patients with symptomatic degenerative disc disease. Keywords: Axia

  11. Hemorrhoidectomy: pedicle ligation vs pedicle coagulation

    International Nuclear Information System (INIS)

    Shaikh, B.S.; Balaoch, I.B.; Sohu, K.M.

    2015-01-01

    Objective: To compare the outcome of pedicle ligation vs pedicle coagulation haemorrhoidectomy. Methodology: This comparative prospective study was carried out at Department of Surgery, Ghulam Muhammad Maher Medcial College Hospital, Sukkur, Pakistan from January 2011 to January 2013 and included 300 patients of hemorrhoids. After routine workup, patients were randomly divided into two equal groups with one group receiving pedicle ligation and other pedicle coagulation for hemorrhoidectomy. Postoperatively they were followed for a period of 8 weeks for complications including pain, urinary retention, bleeding and anal stricture. Pain was recorded up to 10th postoperative day on the basis of visual analogue scale. Results: Mean age was 45 years and male to female ratio was 1.7:1. Mean operative time in pedicle ligation group was 15 min (range 14-20 min) and 17 min (15-25 min) in pedicle coagulation group. In Pedicle ligation group, pain was worst in 35 patients, moderate in 85 and mild in 30 patients; on the other hand in pedicle coagulation group, just 09 patients experienced worst pain. Urinary retention was observed in 44 patients in pedicle ligation group and 19 in pedicle coagulation group. Five patients in pedicle ligation group developed bleeding after their discharge from hospital; 7 patients in pedicle coagulation group reported secondary bleeding. Anal stricture was a rare complication and was found equally common in both the groups. Conclusion: Conventional hemorrhoidectomy with pedicle coagulation is an effective treatment modality for hemorrhoids and is associated with less chance of postoperative anal pain and urinary retention. (author)

  12. Acute lumbar spondylolysis in intercollegiate athletes.

    Science.gov (United States)

    Sutton, Jeremy Hunter; Guin, Patrick D; Theiss, Stephen M

    2012-12-01

    A retrospective case series. The purpose of this study was to describe a unique group of intercollegiate athletes who are skeletally mature and who developed symptomatic acute lumbar spondylolysis and to study long-term return to play outcome of nonoperative and surgical repair of L3 and L4 spondylolysis in skeletally mature athletes. Traditionally, symptomatic acute lumbar spondylolysis is a defect found in skeletally immature athletes, most commonly in the pars interarticularis of L5, less commonly in the L3/L4 region, and even less commonly in skeletally mature athletes as described in this group. Eight intercollegiate athletes (2 women and 6 men, ages ranging from 19 to 21 y) with acute lumbar spondylolysis were diagnosed by means of computed tomography (CT) and single photon emission-CT bone scan. L3 lesions were present in 5 patients, and L4 lesions were present in 3 patients. All patients were treated initially nonoperatively with a protocol of bracing and activity modification. The healing progress was assessed through repeat CT scan. Patients who failed to respond to nonoperative procedures underwent direct repair of their pars defect through variable angle pedicle screw and sublaminar hook. Outcomes were measured by completion of the Oswestry Low Back Pain Disability Questionnaire (mean follow-up 6.5 y) and return to athletic participation. All patients successfully returned to full athletic competition. Two patients showed radiographic healing and resolution of pain following 3 months of nonoperative treatment. Five patients required surgical repair of the pars defect. All of these patients eventually returned to unrestricted participation in athletics. This study shows that this subgroup will generally respond well to surgical correction of the pars defect and return to uninhibited competition following conservative treatment and/or surgical repair.

  13. Risk factors for adjacent segment degeneration after surgical correction of degenerative lumbar scoliosis

    Directory of Open Access Journals (Sweden)

    Kee-yong Ha

    2013-01-01

    Full Text Available Background: Degenerative lumbar scoliosis surgery can lead to development of adjacent segment degeneration (ASD after lumbar or thoracolumbar fusion. Its incidence, risk factors, morbidity and correlation between radiological and clinical symptoms of ASD have no consensus. We evaluated the correlation between the occurrence of radiologic adjacent segment disease and certain imperative parameters. Materials and Methods: 98 patients who had undergone surgical correction and lumbar/thoracolumbar fusion with pedicle screw instrumentation for degenerative lumbar scoliosis with a minimum 5 year followup were included in the study. We evaluated the correlation between the occurrence of radiologic adjacent segment disease and imperative patient parameters like age at operation, sex, body mass index (BMI, medical comorbidities and bone mineral density (BMD. The radiological parameters taken into consideration were Cobb′s angle, angle type, lumbar lordosis, pelvic incidence, intercristal line, preoperative existence of an ASD on plain radiograph and magnetic resonance imaging (MRI and surgical parameters were number of the fusion level, decompression level, floating OP (interlumbar fusion excluding L5-S1 level and posterolateral lumbar interbody fusion (PLIF. Clinical outcomes were assessed with the Visual Analogue Score (VAS and Oswestry Disability Index (ODI. Results: ASD was present in 44 (44.9% patients at an average period of 48.0 months (range 6-98 months. Factors related to occurrence of ASD were preoperative existence of disc degeneration (as revealed by MRI and age at operation ( P = 0.0001, 0.0364. There were no statistically significant differences between radiological adjacent segment degeneration and clinical results (VAS, P = 0.446; ODI, P = 0.531. Conclusions: Patients over the age of 65 years and with preoperative disc degeneration (as revealed by plain radiograph and MRI were at a higher risk of developing ASD.

  14. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    OpenAIRE

    Hughes Matthew; Papadakos Nikolaos; Bishop Tim; Bernard Jason

    2018-01-01

    Introduction: Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Methods: Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar sp...

  15. Properties of an interspinous fixation device (ISD) in lumbar fusion constructs: a biomechanical study.

    Science.gov (United States)

    Techy, Fernando; Mageswaran, Prasath; Colbrunn, Robb W; Bonner, Tara F; McLain, Robert F

    2013-05-01

    Segmental fixation improves fusion rates and promotes patient mobility by controlling instability after lumbar surgery. Efforts to obtain stability using less invasive techniques have lead to the advent of new implants and constructs. A new interspinous fixation device (ISD) has been introduced as a minimally invasive method of stabilizing two adjacent interspinous processes by augmenting an interbody cage in transforaminal interbody fusion. The ISD is intended to replace the standard pedicle screw instrumentation used for posterior fixation. The purpose of this study is to compare the rigidity of these implant systems when supplementing an interbody cage as used in transforaminal lumbar interbody fusion. An in vitro human cadaveric biomechanical study. Seven human cadaver spines (T12 to the sacrum) were mounted in a custom-designed testing apparatus, for biomechanical testing using a multiaxial robotic system. A comparison of segmental stiffness was carried out among five conditions: intact spine control; interbody spacer (IBS), alone; interbody cage with ISD; IBS, ISD, and unilateral pedicle screws (unilat); and IBS, with bilateral pedicle screws (bilat). An industrial robot (KUKA, GmbH, Augsburg, Germany) applied a pure moment (±5 Nm) in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) through an anchor to the T12 vertebral body. The relative vertebral motion was captured using an optoelectronic camera system (Optotrak; Northern Digital, Inc., Waterloo, Ontario, Canada). The load sensor and the camera were synchronized. Maximum rotation was measured at each level and compared with the intact control. Implant constructs were compared with the control and with each other. A statistical analysis was performed using analysis of variance. A comparison between the intact spine and the IBS group showed no significant difference in the range of motion (ROM) in FE, LB, or AR for the operated level, L3-L4. After implantation of the ISD to augment

  16. Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

    Directory of Open Access Journals (Sweden)

    Jan-Helge Klingler

    2015-01-01

    Full Text Available Purpose. To describe the minimally invasive technique for cement augmentation of cannulated and fenestrated screws using an injection cannula as well as to report its safety and efficacy. Methods. A total of 157 cannulated and fenestrated pedicle screws had been cement-augmented during minimally invasive posterior screw-rod spondylodesis in 35 patients from January to December 2012. Retrospective evaluation of cement extravasation and screw loosening was carried out in postoperative plain radiographs and thin-sliced triplanar computed tomography scans. Results. Twenty-seven, largely prevertebral cement extravasations were detected in 157 screws (17.2%. None of the cement extravasations was causing a clinical sequela like a new neurological deficit. One screw loosening was noted (0.6% after a mean follow-up of 12.8 months. We observed no cementation-associated complication like pulmonary embolism or hemodynamic insufficiency. Conclusions. The presented minimally invasive cement augmentation technique using an injection cannula facilitates convenient and safe cement delivery through polyaxial cannulated and fenestrated screws during minimally invasive screw-rod spondylodesis. Nevertheless, the optimal injection technique and design of fenestrated screws have yet to be identified. This trial is registered with German Clinical Trials DRKS00006726.

  17. Can cantilever transforaminal lumbar interbody fusion (C-TLIF) maintain segmental lordosis for degenerative spondylolisthesis on a long-term basis?

    Science.gov (United States)

    Kida, Kazunobu; Tadokoro, Nobuaki; Kumon, Masashi; Ikeuchi, Masahiko; Kawazoe, Tateo; Tani, Toshikazu

    2014-03-01

    To determine if cantilever transforaminal lumbar interbody fusion (C-TLIF) using the crescent-shaped titanium interbody spacer (IBS) favors acquisition of segmental and lumbar lordosis even for degenerative spondylolisthesis (DS) on a long-term basis. We analyzed 23 consecutive patients who underwent C-TLIF with pedicle screw instrumentations fixed with compression for a single-level DS. Measurements on the lateral radiographs taken preoperatively, 2 weeks postoperatively and at final follow-up included disc angle (DA), segmental angle (SA), lumbar lordosis (LL), disc height (%DH) and slip rate (%slip). There was a good functional recovery with 100 % fusion rate at the mean follow-up of 62 months. Segmental lordosis (DA and SA) and %DH initially increased, but subsequently decreased with the subsidence of the interbody spacer, resulting in a significant increase (p = 0.046) only in SA from 13.2° ± 5.5° preoperatively to 14.7° ± 6.4° at the final follow-up. Changes of LL and %slip were more consistent without correction loss finally showing an increase of LL by 3.6° (p = 0.005) and a slip reduction by 6.7 % (p lordosis on a long-term basis, which would be of benefit in preventing hypolordosis-induced back pain and the adjacent level disc disease.

  18. Radiological outcome of transpedicular screws fixation in the management of thoracolumbar spine injury

    International Nuclear Information System (INIS)

    Haq, M.I.U.

    2015-01-01

    Traumatic fracture of the spine is a serious neurosurgical condition that has serious impact on the patient's quality of life. Thoracolumbar junction is the most common site of spinal injuries. The aims of management of thoracolumbar spinal fractures are to restore vertebral column stability, and to obtain spinal canal decompression. This ultimately leads to early mobilization of the patients. This study was conducted to compare preoperative and post-operative vertebral height, kyphotic angle and sagittal index in patients treated with pedicle screws and rods in thoracolumbar spine fractures. Methods: This cross-sectional study was conducted in the department of Neurosurgery, Hayatabad Medical Complex, Peshawar from 1st February 2010 to 31st July 2011. A total 161 patients with unstable thoracolumber spine fracture were included in this study. In these patients fixation was done through transpedicle screws with rods. Anteroposterior and lateral views X-rays of thoraco-lumbar spine were done pre and post operatively. Results: Out of 161 patients, 109 (67.7%) were males and 52 (32.3%) females. The age of patients ranged from 20 to 70 years (mean 42.2 years) with 71 (44.1%) in the age range of 31-40 years. Preoperative average vertebral height was 9.4194 mm while postoperative average was 19.642 mm. The mean kyphosis was 23.06 degree preoperatively. Immediately after surgery the average correction of kyphosis was 9.45 degree. The pre-operative average sagittal index was 19.38 degree, which was reduced to an average 5.41 degree post operatively. Conclusions: Transpedicular fixation for unstable thoraco-lumbar spinal fractures achieves a stable fracture segment with improvement of vertebral height, kyphotic angle and sagittal index. Hence, preventing the secondary spinal deformities. (author)

  19. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    Science.gov (United States)

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  20. Reproducibility of thoracic kyphosis measurements in patients with adolescent idiopathic scoliosis

    DEFF Research Database (Denmark)

    Ohrt-Nissen, Søren; Cheung, Jason Pui Yin; Hallager, Dennis Winge

    2017-01-01

    ) surgically treated for AIS with alternate-level pedicle screw fixation were included in the study. Three raters independently evaluated pre- and postoperative standing lateral plain radiographs. For each radiograph, several definitions of TK were measured as well as L1-S1 and nonfixed lumbar lordosis. All...

  1. Hybrid dynamic stabilization: a biomechanical assessment of adjacent and supraadjacent levels of the lumbar spine.

    Science.gov (United States)

    Mageswaran, Prasath; Techy, Fernando; Colbrunn, Robb W; Bonner, Tara F; McLain, Robert F

    2012-09-01

    The object of this study was to evaluate the effect of hybrid dynamic stabilization on adjacent levels of the lumbar spine. Seven human spine specimens from T-12 to the sacrum were used. The following conditions were implemented: 1) intact spine; 2) fusion of L4-5 with bilateral pedicle screws and titanium rods; and 3) supplementation of the L4-5 fusion with pedicle screw dynamic stabilization constructs at L3-4, with the purpose of protecting the L3-4 level from excessive range of motion (ROM) and to create a smoother motion transition to the rest of the lumbar spine. An industrial robot was used to apply continuous pure moment (± 2 Nm) in flexion-extension with and without a follower load, lateral bending, and axial rotation. Intersegmental rotations of the fused, dynamically stabilized, and adjacent levels were measured and compared. In flexion-extension only, the rigid instrumentation at L4-5 caused a 78% decrease in the segment's ROM when compared with the intact specimen. To compensate, it caused an increase in motion at adjacent levels L1-2 (45.6%) and L2-3 (23.2%) only. The placement of the dynamic construct at L3-4 decreased the operated level's ROM by 80.4% (similar stability as the fusion at L4-5), when compared with the intact specimen, and caused a significant increase in motion at all tested adjacent levels. In flexion-extension with a follower load, instrumentation at L4-5 affected only a subadjacent level, L5-sacrum (52.0%), while causing a reduction in motion at the operated level (L4-5, -76.4%). The dynamic construct caused a significant increase in motion at the adjacent levels T12-L1 (44.9%), L1-2 (57.3%), and L5-sacrum (83.9%), while motion at the operated level (L3-4) was reduced by 76.7%. In lateral bending, instrumentation at L4-5 increased motion at only T12-L1 (22.8%). The dynamic construct at L3-4 caused an increase in motion at T12-L1 (69.9%), L1-2 (59.4%), L2-3 (44.7%), and L5-sacrum (43.7%). In axial rotation, only the placement of

  2. Sagittal curve and high metal density in adolescent idiopathic scoliosis

    Directory of Open Access Journals (Sweden)

    Fabio Araújo Fernandes

    2014-01-01

    Full Text Available Objectives: To analyze radiographically the postoperative kyphosis from patients undergoing surgical treatment for AIS with pedicle screws in all vertebrae included in the arthrodesis. Methods: Retrospective study. The following measurements were evaluated: Cobb angle in anteroposterior radiograph of the three curves (proximal thoracic, main thoracic, and lumbar, Cobb angle in the lateral view of the two curves: thoracic kyphosis (T5-T12 and lumbar lordosis (T12-S1. Results: Of the 25 patients evaluated preoperatively, four (16% were hypokyphotic, 20 patients (80% were normokyphotic and only one (4% was hyperkyphotic. For hypokyphotic and hiperkyphotic patients a satisfactory correction of thoracic kyphosis was obtained in 100% of cases, which was preserved in the final result. The same pattern of thoracic kyphosis was observed for all normokyphotic patients throughout the follow-up. Conclusion: Radiographic evaluation of thoracic kyphosis in patients with AIS treated surgically with pedicle screws in all vertebrae showed satisfactory results with respect to the correction of thoracic kyphosis.

  3. The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.

    Science.gov (United States)

    Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin

    2017-07-28

    Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.

  4. Morphology of the atlas pedicle revisited: a morphometric CT-based study on 120 patients.

    Science.gov (United States)

    Qian, Li-Xiong; Hao, Ding-Jun; He, Bao-Rong; Jiang, Yong-Hong

    2013-05-01

    To quantify the dimensions of the atlas pedicles and to analyze the relationship between extra medullary height (EMH) with intra medullary height (IMH) of the atlas pedicle. The images of the patients who had CT scanning and three-dimensional (3D) reconstruction involving atlantoaxial complex between June 2011 and April 2012 and meet our inclusion criteria were studied retrospectively. After reformatting the original images, the EMH and IMH of the atlas pedicles were measured. Extra medullary height and IMH were, respectively, 4.83 ± 1.13 and 1.29 ± 1.10 mm for males and 3.75 ± 0.93 and 0.60 ± 0.83 mm for females, with statistical difference (P atlas pedicles were measured by using CT images of the atlas, providing anatomic parameters for surgery. They showed a certain correlation but with a high variability. C1 pedicle screw fixation was well performed when the medullary canal was ≥1 mm, but the surgical procedure should be careful when it was between 0 and 1 mm, and avoided when there was no medullary canal in the atlas pedicle! So 3D CT reconstruction should be conducted to obtain data and establish individualized fixation strategy preoperatively.

  5. Posterior-only approach for lumbar vertebral column resection and expandable cage reconstruction for spinal metastases.

    Science.gov (United States)

    Jandial, Rahul; Kelly, Brandon; Chen, Mike Yue

    2013-07-01

    The increasing incidence of spinal metastasis, a result of improved systemic therapies for cancer, has spurred a search for an alternative method for the surgical treatment of lumbar metastases. The authors report a single-stage posterior-only approach for resecting any pathological lumbar vertebral segment and reconstructing with a medium to large expandable cage while preserving all neurological structures. The authors conducted a retrospective consecutive case review of 11 patients (5 women, 6 men) with spinal metastases treated at 1 institution with single-stage posterior-only vertebral column resection and reconstruction with an expandable cage and pedicle screw fixation. For all patients, the indications for operative intervention were spinal cord compression, cauda equina compression, and/or spinal instability. Neurological status was classified according to the American Spinal Injury Association impairment scale, and functional outcomes were analyzed by using a visual analog scale for pain. For all patients, a circumferential vertebral column resection was achieved, and full decompression was performed with a posterior-only approach. Each cage was augmented by posterior pedicle screw fixation extending 2 levels above and below the resected level. No patient required a separate anterior procedure. Average estimated blood loss and duration of each surgery were 1618 ml (range 900-4000 ml) and 6.6 hours (range 4.5-9 hours), respectively. The mean follow-up time was 14 months (range 10-24 months). The median survival time after surgery was 17.7 months. Delayed hardware failure occurred for 1 patient. Preoperatively, 2 patients had intractable pain with intact lower-extremity strength and 8 patients had severe intractable pain, lower-extremity paresis, and were unable to walk; 4 of whom regained the ability to walk after surgery. Two patients who were paraplegic before decompression recovered substantial function but remained wheelchair bound, and 2 patients

  6. Congenital lumbar spinal stenosis: a prospective, control-matched, cohort radiographic analysis.

    Science.gov (United States)

    Singh, Kern; Samartzis, Dino; Vaccaro, Alexander R; Nassr, Ahmad; Andersson, Gunnar B; Yoon, S Tim; Phillips, Frank M; Goldberg, Edward J; An, Howard S

    2005-01-01

    Degenerative lumbar spinal stenosis manifests primarily after the sixth decade of life as a result of facet hypertrophy and degenerative disc disease. Congenital stenosis, on the other hand, presents earlier in age with similar clinical findings but with multilevel involvement and fewer degenerative changes. These patients may have subtle anatomic variations of the lumbar spine that may increase the likelihood of thecal sac compression. However, to the authors' knowledge, no quantitative studies have addressed various radiographic parameters of symptomatic, congenitally stenotic individuals to normal subjects. To radiographically quantify and compare the anatomy of the lumbar spine in symptomatic, congenitally stenotic individuals to age- and sex-matched, asymptomatic, nonstenotic controlled individuals. A prospective, control-matched, cohort radiographic analysis. Axial and sagittal magnetic resonance imaging (MRI) and lateral, lumbar, plain radiographs of 20 surgically treated patients who were given a clinical diagnosis of congenital lumbar stenosis by the senior author were randomized with images of 20, asymptomatic age- and sex-matched subjects. MRIs and lateral, lumbar, plain radiographs were independently quantitatively assessed by two individuals. Measurements obtained from the axial MRIs included: midline anterior-posterior (AP) vertebral body diameter, vertebral body width, midline AP canal diameter, canal width, spinal canal cross-sectional area, pedicle length, and pedicle width. From the sagittal MRIs, the following measurements were calculated: AP vertebral body diameter, vertebral body height, and AP canal diameter at the mid-vertebral level. On the lateral, lumbar, plain radiograph (L3 level), the AP diameters of the vertebral body spinal canal were measured. The images of these 40 individuals were then randomized and distributed in a blinded fashion to five separate spine surgeons who graded the presence and severity of congenital stenosis

  7. Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level

    DEFF Research Database (Denmark)

    Hallager, Dennis Winge; Gehrchen, Poul Martin; Dahl, Benny

    2016-01-01

    and rod strain is necessary to determine the biomechanical efficacy of these techniques. METHODS: Five specimens (T12-S1) underwent PSO at L3 with pedicle screw stabilization at L1-S1. Pedicle subtraction was adjusted to achieve a final lordosis of 70°. Flexion-extension (FE), lateral bending, and axial...

  8. Biomechanical demands on posterior fusion instrumentation during lordosis restoration procedures.

    Science.gov (United States)

    Kuo, Calvin C; Martin, Audrey; Telles, Connor; Leasure, Jeremi; Iezza, Alex; Ames, Christopher; Kondrashov, Dimitriy

    2016-09-01

    OBJECTIVE The goal of this study was to investigate the forces placed on posterior fusion instrumentation by 3 commonly used intraoperative techniques to restore lumbar lordosis: 1) cantilever bending; 2) in situ bending; and 3) compression and/or distraction of screws along posterior fusion rods. METHODS Five cadaveric torsos were instrumented with pedicle screws at the L1-5 levels. Specimens underwent each of the 3 lordosis restoration procedures. The pedicle screw pullout force was monitored in real time via strain gauges that were mounted unilaterally at each level. The degree of correction was noted through fluoroscopic imaging. The peak loads experienced on the screws during surgery, total demand on instrumentation, and resting loads after corrective maneuvers were measured. RESULTS A mean overall lordotic correction of 10.9 ± 4.7° was achieved. No statistically significant difference in lordotic correction was observed between restoration procedures. In situ bending imparted the largest loads intraoperatively with an average of 1060 ± 599.9 N, followed by compression/distraction (971 ± 534.1 N) and cantilever bending (705 ± 413.0 N). In situ bending produced the largest total demand and postoperative loads at L-1 (1879 ± 1064.1 and 487 ± 118.8 N, respectively), which were statistically higher than cantilever bending and compression/distraction (786 ± 272.1 and 138 ± 99.2 N, respectively). CONCLUSIONS In situ bending resulted in the highest mechanical demand on posterior lumbar instrumentation, as well as the largest postoperative loads at L-1. These results suggest that the forces generated with in situ bending indicate a greater chance of intraoperative instrumentation failure and postoperative proximal pedicle screw pullout when compared with cantilever bending and/or compression/distraction options. The results are aimed at optimizing correction and fusion strategies in lordosis restoration cases.

  9. Repeated adjacent-segment degeneration after posterior lumbar interbody fusion.

    Science.gov (United States)

    Okuda, Shinya; Oda, Takenori; Yamasaki, Ryoji; Maeno, Takafumi; Iwasaki, Motoki

    2014-05-01

    One of the most important sequelae affecting long-term results is adjacent-segment degeneration (ASD) after posterior lumbar interbody fusion (PLIF). Although several reports have described the incidence rate, there have been no reports of repeated ASD. The purpose of this report was to describe 1 case of repeated ASD after PLIF. A 62-year-old woman with L-4 degenerative spondylolisthesis underwent PLIF at L4-5. At the second operation, L3-4 PLIF was performed for L-3 degenerative spondylolisthesis 6 years after the primary operation. At the third operation, L2-3 PLIF was performed for L-2 degenerative spondylolisthesis 1.5 years after the primary operation. Vertebral collapse of L-1 was detected 1 year after the third operation, and the collapse had progressed. At the fourth operation, 3 years after the third operation, vertebral column resection of L-1 and replacement of titanium mesh cages with pedicle screw fixation between T-4 and L-5 was performed. Although the patient's symptoms resolved after each operation, the time between surgeries shortened. The sacral slope decreased gradually although each PLIF achieved local lordosis at the fused segment.

  10. Adult's Degenerative Scoliosis: Midterm Results of Dynamic Stabilization without Fusion in Elderly Patients—Is It Effective?

    Science.gov (United States)

    Di Silvestre, Mario; Lolli, Francesco; Greggi, Tiziana; Vommaro, Francesco; Baioni, Andrea

    2013-01-01

    Study Design. A retrospective study. Purpose. Posterolateral fusion with pedicle screw instrumentation used for degenerative lumbar scoliosis can lead to several complications. In elderly patients without sagittal imbalance, dynamic stabilization could represent an option to avoid these adverse events. Methods. 57 patients treated by dynamic stabilization without fusion were included. All patients had degenerative lumbar de novo scoliosis (average Cobb angle 17.2°), without sagittal imbalance, associated in 52 cases (91%) with vertebral canal stenosis and in 24 (42%) with degenerative spondylolisthesis. Nineteen patients (33%) had previously undergone lumbar spinal surgery. Results. At an average followup of 77 months, clinical results improved with statistical significance. Scoliosis Cobb angle was 17.2° (range, 12° to 38°) before surgery and 11.3° (range, 4° to 26°) at last follow-up. In the patients with associated spondylolisthesis, anterior vertebral translation was 19.5% (range, 12% to 27%) before surgery, 16.7% (range, 0% to 25%) after surgery, and 17.5% (range, 0% to 27%) at followup. Complications incidence was low (14%), and few patients required revision surgery (4%). Conclusions. In elderly patients with mild degenerative lumbar scoliosis without sagittal imbalance, pedicle screw-based dynamic stabilization is an effective option, with low complications incidence, granting curve stabilization during time and satisfying clinical results. PMID:23781342

  11. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  12. The SNAP trial: a double blind multi-center randomized controlled trial of a silicon nitride versus a PEEK cage in transforaminal lumbar interbody fusion in patients with symptomatic degenerative lumbar disc disorders: study protocol

    Science.gov (United States)

    2014-01-01

    Background Polyetheretherketone (PEEK) cages have been widely used in the treatment of lumbar degenerative disc disorders, and show good clinical results. Still, complications such as subsidence and migration of the cage are frequently seen. A lack of osteointegration and fibrous tissues surrounding PEEK cages are held responsible. Ceramic implants made of silicon nitride show better biocompatible and osteoconductive qualities, and therefore are expected to lower complication rates and allow for better fusion. Purpose of this study is to show that fusion with the silicon nitride cage produces non-inferior results in outcome of the Roland Morris Disability Questionnaire at all follow-up time points as compared to the same procedure with PEEK cages. Methods/Design This study is designed as a double blind multi-center randomized controlled trial with repeated measures analysis. 100 patients (18–75 years) presenting with symptomatic lumbar degenerative disorders unresponsive to at least 6 months of conservative treatment are included. Patients will be randomly assigned to a PEEK cage or a silicon nitride cage, and will undergo a transforaminal lumbar interbody fusion with pedicle screw fixation. Primary outcome measure is the functional improvement measured by the Roland Morris Disability Questionnaire. Secondary outcome parameters are the VAS leg, VAS back, SF-36, Likert scale, neurological outcome and radiographic assessment of fusion. After 1 year the fusion rate will be measured by radiograms and CT. Follow-up will be continued for 2 years. Patients and clinical observers who will perform the follow-up visits will be blinded for type of cage used during follow-up. Analyses of radiograms and CT will be performed independently by two experienced radiologists. Discussion In this study a PEEK cage will be compared with a silicon nitride cage in the treatment of symptomatic degenerative lumbar disc disorders. To our knowledge, this is the first randomized controlled

  13. Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model

    Directory of Open Access Journals (Sweden)

    Kalpit N. Shah

    2018-03-01

    Full Text Available Instrumentation failure is a common complication following complex spinal reconstruction and deformity correction. Rod fracture is the most frequent mode of hardware failure and often occurs at or near a 3-column osteotomy site. Titanium (Ti rods are commonly utilized for spinal fixations, however, theoretically stiffer materials, such as cobalt-chrome (CoCr rods are also available. Despite ongoing use in clinical practice, there is little biomechanical evidence that compares the construct ability to withstand fatigue stress for Ti and Co-Cr rods. Six models using 2 polyethylene blocks each were used to simulate a pedicle subtraction osteotomy. Within each block 6.0×45 mm polyaxial screws were placed and connected to another block using either two 6.0×100 mm Ti (3 models or CoCr rods (3 models. The rods were bent to 40° using a French bender and were secured to the screws to give a vertical height of 1.5 cm between the blocks. The blocks were fatigue tested with 700N at 4 Hz until failure. The average number of cycles to failure for the Ti rod models was 12840 while the CoCr rod models failed at a significantly higher, 58351 cycles (P=0.003. All Ti models experienced rod fracture as the mode of failure. Two out of the three CoCr models had rod fractures while the last sample failed via screw fracture at the screw-tulip junction. The risk of rod failure is substantial in the setting of long segment spinal arthrodesis and corrective osteotomy. Efforts to increase the mechanical strength of posterior constructs may reduce the occurrence of this complication. Utilizing CoCr rods in patients with pedicle subtraction osteotomy may reduce the rate of device failure during maturation of the posterior fusion mass and limit the need for supplemental anterior column support.

  14. [Clinical effects of Dynesys system and transfacet decompression through Wiltse approach in the treatment of lumbar degenerative diseases].

    Science.gov (United States)

    Shang, K; Chen, M J; Wang, D G

    2017-05-23

    Objective: To investigate the early clinical effects of Dynesys system and transfacet decompression by Wiltse approach in the treatment of lumbar degenerative diseases. Methods: From January 2010 to December 2013, 48 patients suffering from lumbar degenerative diseases were treated with Dynesys system in addition to transfacet decompression through Wiltse approach.There were 28 males and 20 females with age of (51.8±6.8). The preoperative diagnosis included lumbar spinal stenosis(10 cases); lumber intervertebral disc herniation (38 cases). There were 23 cases in L4/5, 16 cases in L5/S1 and 9 cases in both of L4/5 and L5/S1.Posterolateral fixation with Dynesys pedicle screw through Wiltse approach.Unilateral resection of the inferior articular facet of the superior vertebra and the superior articular facet of the inferior vertebra.Decompression of the vertebral canal until the never root was decompressed satisfactorily.In the end, Dynesys was performed according to normal procedure.VAS, ODI evaluating standards were applied to evaluate the therapeutic effect.The intervertebral space and ROM of the lumbar were observed by X ray. Results: All patients underwent surgery safely without severe complications occurred.The average following up time was 33.5 (24-60) months.Compared with preoperative parameters (7.7±1.3, 70.8±13.5), the scores of VAS and ODI decreased significantly after surgery (2.3±1.5, 23.6±12.2) and at the final follow-up (2.2±1.4, 20.0±9.8) ( P 0.05). X-ray scan showed neither instability or internal fixation loosen, breakage or distortion in follow-up. Conclusion: Dynesys system in addition to transfacet decompression through Wiltse approach is a therapy option for mild lumbar degenerative disease.This method can retention the structure of lumbar posterior complex and the activity of the fixed segment, reduce the risk of low back pain together with nerve root decompressed.The early clinical results are satisfactory.

  15. Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area.

    Science.gov (United States)

    Takemoto, Mitsuru; Fujibayashi, Shunsuke; Ota, Eigo; Otsuki, Bungo; Kimura, Hiroaki; Sakamoto, Takeshi; Kawai, Toshiyuki; Futami, Tohru; Sasaki, Kiyoyuki; Matsushita, Tomiharu; Nakamura, Takashi; Neo, Masashi; Matsuda, Shuich

    2016-06-01

    Image-based navigational patient-specific templates (PSTs) for pedicle screw (PS) placement have been described. With recent advances in three-dimensional computer-aided designs and additive manufacturing technology, various PST designs have been reported, although the template designs were not optimized. We have developed a novel PST design that reduces the contact area without sacrificing stability. It avoids susceptibility to intervening soft tissue, template geometric inaccuracy, and difficulty during template fitting. Fourteen candidate locations on the posterior aspect of the vertebra were evaluated. Among them, locations that had high reproducibility on computed tomography (CT) images and facilitated accurate PS placement were selected for the final PST design. An additive manufacturing machine (EOSINT M270) fabricated the PSTs using commercially pure titanium powder. For the clinical study, 36 scoliosis patients and 4 patients with ossification of the posterior longitudinal ligament (OPLL) were treated with thoracic PSs using our newly developed PSTs. We intraoperatively and postoperatively evaluated the accuracy of the PS hole created by the PST. Based on the segmentation reproducibility and stability analyses, we selected seven small, round contact points for our PST: bilateral superior and inferior points on the transverse process base, bilateral inferior points on the laminar, and a superior point on the spinous process. Clinically, the success rates of PS placement using this PST design were 98.6 % (414/420) for scoliosis patients and 100 % (46/46) for OPLL patients. This study provides a useful design concept for the development and introduction of patient-specific navigational templates for placing PSs.

  16. "Two-step" technique with OsiriXTM to evaluate feasibility of C2 pedicle for surgical fixation

    Directory of Open Access Journals (Sweden)

    Luis Miguel Sousa Marques

    2016-01-01

    Full Text Available Background: Surgical treatment of craniovertebral junction pathology has evolved considerably in recent decades with the implementation of short atlanto-axial fixation techniques, notwhithstanding increasing neurovascular risks. Also, there is strong evidence that fixation of C2 anatomical pedicle has the best biomechanical profile of the entire cervical spine. However, it is often difficult and misleading, to evaluate anatomical bony and vascular anomalies using the three orthogonal planes (axial, coronal, and sagittal of CT. Objectives: The authors describe an innovative and simple technique to evaluate the feasibility of C2 pedicle for surgical screw fixation using preoperative planning with the free DICOM (Digital Imaging and Communications in Medicine software OsiriX TM . Materials and Methods: The authors report the applicatin of this novel technique in 5 cases (3 traumatic, 1 Os Odontoideum, and 1 complex congenital malformation collected from our general case series of the Department in the last 5 years. Results: In this "proof of concept" study, the pre-operative analysis with the "two-step" tecnique was detrimental for choosing the surgical tecnique. Detailed post-operative analysis confirmed correct position of C2 screws without cortical breach. There were no complications or mortality reported. Conclusion: This "two-step" technique is an easy and reliable way to determine the feasibility of C2 pedicle for surgical fixation. The detailed tridimensional radiological preoperative evaluation of craniovertebral junction anatomy is critical to the sucess and safety of this surgeries, and can avoid, to certain degree, expensive intra-operative tridimensional imaging facilities.

  17. Evaluation of osseous integration of titanium orthopedic screws with novel SLA treatment in porcine model.

    Directory of Open Access Journals (Sweden)

    Tzu-Hsiang Lin

    Full Text Available The success of many endosseous implants in orthopaedic and dental applications depends on the surface characteristics, as they affect osseous integration. Previous investigations indicated that a novel large-grit sand-blasted and acid-etched (SLA titanium (denoted as SLAffinity-Ti implant had better bone integration than that of a comparably shaped implant with a plasma-sprayed titanium surface. The purpose of the present investigation was to create a SLAffinity surface on pedicle screws and trauma screws and to compare it with the surfaces of a sand-blasted-only implant and commercial implants in terms of bone integration. The cortical bone and spine of twelve minipigs were implanted with 3 and 4 implants, respectively, and the bone integration was evaluated using micro-computed tomography (micro-CT, mechanical tests (pull-out strength and stripping torque, and histological analysis (toluidine blue and hematoxylin and eosin staining one and three months after implantation. The micro-CT images showed that the gap between the bone and implant was consistently higher in the sand-blasted-only and commercial groups compared to that in the SLAffinity group 1 and 3 months after implantation. Moreover, the bone volume of implant inserted into bone and the percentage of implant inside bone tissue were greater in the SLAffinity screws 1 and 3 months after implantation, as compared to the sand-blasted and commercial screws. In the mechanical tests, the removal torque and pull-out strength (p < 0.05 were higher in the SLAffinity group at 1 and 3 months. The histological results were consistent with mechanical testing, showing that the SLAffinity group had the most mineralized matrix, the most bone formation around the screws, and the most bone cells in bone tissue. These findings indicate that a SLAffinity surface can effectively enhance the holding strength and integration of pedicle screws and cortical screws, promoting early healing and improving

  18. Treatment Results of Injuries of Thoracic and Lumbar Backbone Departments at Osteoporosis Patients

    Directory of Open Access Journals (Sweden)

    D.Y. Sumin

    2009-06-01

    Full Text Available Information relates to radiologic (computer tomography manifestations providing the visualization of thoracic and lumbar backbone department injuries at osteoporotic patients. Contemporary methods of transcutaneous and trans-pedicle vertebroplasty with bone cement allows to obtain a stable positive healing effect against such pathologies.

  19. Pedicular stress fracture in the lumbar spine

    International Nuclear Information System (INIS)

    Chong, V.F.H.; Htoo, M.M.

    1997-01-01

    Spondylolisthesis with or without spondylolysis is common in the lumbar spine. Associated fracture in the pedicle ('pediculolysis') is unusual. The margins of pedicular stress fractures, like spondylolysis, usually appear sclerotic. A patient with a pedicular stress fracture with minimal marginal sclerosis suggesting an injury of recent onset is presented here. There was associated bilateral spondylolysis. The findings in this patient suggest that established pediculolysis probably represents a stress fracture that has failed to heal. (authors)

  20. Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices

    International Nuclear Information System (INIS)

    Ahn, Yoon-Ho; Chen, W-M; Lee, Kwon-Yong; Park, Kyung-Woo; Lee, Sung-Jae

    2008-01-01

    Recently, numerous types of posterior dynamic stabilization (PDS) devices have been introduced as an alternative to the fusion devices for the surgical treatment of degenerative lumbar spine. It is hypothesized that the use of 'compliant' materials such as Nitinol (Ni-Ti alloy, elastic modulus = 75 GPa) or polyether-etherketone (PEEK, elastic modulus = 3.2 GPa) in PDS can restore stability of the lumbar spine without adverse stress-shielding effects that have often been found with 'rigid' fusion devices made of 'rigid' Ti alloys (elastic modulus = 114 GPa). Previous studies have shown that suitably designed PDS devices made of more compliant material may be able to help retain kinematic behavior of the normal spine with optimal load sharing between the anterior and posterior spinal elements. However, only a few studies on their biomechanical efficacies are available. In this study, we conducted a finite-element (FE) study to investigate changes in load-sharing characteristics of PDS devices. The implanted models were constructed after modifying the previously validated intact model of L3-4 spine. Posterior lumbar fusion with three different types of pedicle screw systems was simulated: a conventional rigid fixation system (Ti6Al4V, Φ = 6.0 mm) and two kinds of PDS devices (one with Nitinol rod with a three-coiled turn manner, Φ = 4.0 mm; the other with PEEK rod with a uniform cylindrical shape, Φ = 6.0 mm). To simulate the load on the lumbar spine in a neutral posture, an axial compressive load (400 N) was applied. Subsequently, the changes in load-sharing characteristics and stresses were investigated. When the compressive load was applied on the implanted models (Nitinol rod, PEEK rod, Ti-alloy rod), the predicted axial compressive loads transmitted through the devices were 141.8 N, 109.8 N and 266.8 N, respectively. Axial forces across the PDS devices (Nitinol rod, PEEK rod) and rigid system (Ti-alloy rod) with facet joints were predicted to take over 41%, 33

  1. A computed tomography morphometric study of occipital bone and C2 pedicle anatomy for occipital-cervical fusion.

    Science.gov (United States)

    King, Nicolas K K; Rajendra, Tiruchelvarayan; Ng, Ivan; Ng, Wai Hoe

    2014-01-01

    Occipital-cervical fusion (OCF) has been used to treat instability of the occipito-cervical junction and to provide biomechanical stability after decompressive surgery. The specific areas that require detailed morphologic knowledge to prevent technical failures are the thickness of the occipital bone and diameter of the C2 pedicle, as the occipital midline bone and the C2 pedicle have structurally the strongest bone to provide the biomechanical purchase for cranio-cervical instrumentation. The aim of this study was to perform a quantitative morphometric analysis using computed tomography (CT) to determine the variability of the occipital bone thickness and C2 pedicle thickness to optimize screw placement for OCF in a South East Asian population. Thirty patients undergoing cranio-cervical junction instrumentation during the period 2008-2010 were included. The thickness of the occipital bone and the length and diameter of the C2 pedicle were measured based on CT. The thickest point on the occipital bone was in the midline with a maximum thickness below the external occipital protuberance of 16.2 mm (±3.0 mm), which was thicker than in the Western population. The average C2 pedicle diameter was 5.3 mm (±2.0 mm). This was smaller than Western population pedicle diameters. The average length of the both pedicles to the midpoint of the C2 vertebral body was 23.5 mm (±3.3 mm on the left and ±2.3 mm on the right). The results of this first study in the South East Asian population should help guide and improve the safety in occipito-cervical region instrumentation. Thus reducing the risk of technical failures and neuro-vascular injury.

  2. THE USE OF NITINOL RODS IN SURGICAL TREATMENT OF DEGENERATIVE SCOLIOSIS. 2.5-YEAR FOLLOW-UP

    Directory of Open Access Journals (Sweden)

    Natalia Sergeyevna Morozova

    2016-03-01

    Full Text Available ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases pedicle screws and nitinol rods with a diameter of 5.5 mm were used. Thirty patients underwent fixation at L1-S1 and 40 patients underwent fixation at L1-L5. Spinal fusion was not performed. All patients had radiography, CT and MRI performed. The results were assessed according to the Oswestry scale, SRS 22, SF 36 and VAS. The minimum follow-up period for all patients was 2.5 years. For the control group, consisting of 72 patients, pedicle fixation with titanium rods and interbody fusion in the lumbosacral region were performed. Results: The average level of deformity correction equaled 25° (10° - 38°. The analysis of X-ray and CT-scans revealed a single patient with implant instability, two patients with bone resorption around the screws and one patient with rod fractures. Functional radiography 2.5 years after surgery showed an average mobility of the lumbar spine of 21° (15° - 30°. There were no problems at the adjacent levels. Conclusions: The use of nitinol rods in spinal deformity surgery is promising. This technology is an alternative to rigid fixation. Continued gathering of clinical data and its further evaluation is necessary.

  3. Evaluation of the Results of Posterior Decompression, Corpectomy and Instrumentation in Traumatic Unstable Thoraco-Lumbar Burst Fractures

    Directory of Open Access Journals (Sweden)

    Md. Anowarul Islam

    2012-06-01

    Full Text Available Background: Thoraco-lumbar burst fractures occur as a result of axial load which often causes displacement of the middle column into the vertebral canal. Posterior surgery reduces the morbid outcomes of different other approaches. Objective: To evaluate the clinical and radiological success of posterior corpectomy and instrumentation in the management of traumatic unstable thoraco-lumbar burst fractures. Methods: It is a prospective interventional study carried out in Bangabandhu Sheikh Mujib Medical University and different private hospitals in Dhaka from July 2008 to December 2011. Total 18 patients; 13 male and 05 female within an age range of 21-40 years were selected. Total 09 cases involved L1, 05 cases at D12, 02 cases at D11 and at L2 each. Neurological status was assessed by Frankel‘s grading and pain status by Visual Analogue Score (VAS. Paired t-test was used for statistical analysis. Results: All the patients were followed up for minimum 1 year. Eleven out of 12 patients with Frankel grade-B and 04 patients out of 06 with Frankel grade-C recovered fully and could walk without support (p<0.05. Overall 03 patients ended with some degrees of persistant neurological deficit. The mean postoperative pain improvement and kyphotic angle correction was significant  (p<0.05. Conclusion: Decompression through posterior approach by laminectomy, corpectomy and fusion by cage with bone graft and stabilization by pedicle screw and rod significantly improves the clinical and radiological outcome in management of traumatic unstable thoraco-lumbar burst fractures.DOI: http://dx.doi.org/10.3329/bsmmuj.v5i1.10998 BSMMU J 2012; 5(1:35-41 

  4. Occam paradox? A variation of tapia syndrome and an unreported complication of guidewire-assisted pedicle screw insertion.

    Science.gov (United States)

    Emohare, Osa; Peterson, Erik; Slinkard, Nathaniel; Janus, Seth; Morgan, Robert

    2013-10-01

    Study Design Case report. Clinical Question The clinical aim is to report on a previously unknown association between guidewire-assisted pedicle screw insertion and neuropraxia of the recurrent laryngeal nerve (RLN), and how this may overlap with the signs of Tapia syndrome; we also report our approach to the clinical management of this patient. Methods A 17-year-old male patient with idiopathic scoliosis experienced Tapia syndrome after posterior instrumentation and arthrodesis at the level of T1-L1. After extubation, the patient had a hoarse voice and difficulty in swallowing. Imaging showed a breach in the cortex of the anterior body of T1 corresponding to the RLN on the right. Results Otolaryngological examination noted right vocal fold immobility, decreased sensation of the endolarynx, and pooling of secretions on flexible laryngoscopy that indicated right-sided cranial nerve X injury and left-sided tongue deviation. Aspiration during a modified barium swallow prompted insertion of a percutaneous endoscopic gastrostomy tube before the patient was sent home. On postoperative day 20, a barium swallow demonstrated reduced aspiration, and the patient reported complete resolution of symptoms. The feeding tube was removed, and the patient resumed a normal diet 1 month later. Tapia syndrome, or persistent unilateral laryngeal and hypoglossal paralysis, is an uncommon neuropraxia, which has previously not been observed in association with a breached vertebral body at T1 along the course of the RLN. Conclusion Tapia syndrome should be a differential diagnostic consideration whenever these symptoms persist postoperatively and spine surgeons should be aware of this as a potential complication of guidewires in spinal instrumentation.

  5. Pedicular stress fracture in the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Chong, V.F.H.; Htoo, M.M. [Singapore General Hospital, Singapore, (Singapore). Department of Diagnostic Radiology

    1997-08-01

    Spondylolisthesis with or without spondylolysis is common in the lumbar spine. Associated fracture in the pedicle (`pediculolysis`) is unusual. The margins of pedicular stress fractures, like spondylolysis, usually appear sclerotic. A patient with a pedicular stress fracture with minimal marginal sclerosis suggesting an injury of recent onset is presented here. There was associated bilateral spondylolysis. The findings in this patient suggest that established pediculolysis probably represents a stress fracture that has failed to heal. (authors). 10 refs., 2 figs.

  6. The values of MSCT multi-planar reconstruction in the diagnosis of lumbar spondylolysis

    International Nuclear Information System (INIS)

    Tan Qixuan; Zhu Gangming; Qian Huirong; Zhong Sheng

    2007-01-01

    Objective: To study the reasonable schedule and diagnostic values of MSCT multi-planar reconstruction in patients with lumbar spondylolysis. Methods: Volume scan ranging from T12 to S1 was done in 540 cases suffered from backleg pain without definite trauma. The lumbar disc axial and whole lumbar axial, sagital, coronal images were reconstructed from raw data of MSCT. Results: Of the 540 cases, 54 spondylolysis in isthmus of lumbar pedicle were demonstrated in 29 ones (29/540, 5.37%). 20 cases were accompanied with spondylolisthesis. The sagital multi-planar reconstruction was the best way to reveal the fissures of spondylolysis and accompanying abnormalities. The detectable ratio of fissures in lumbar disc with axial, whole lumbar axial, sagital and coronal multi-planer reconstruction images were 7.41%, 100%, 100% and 51.85% respectively. Conclusions: MSCT sagital multi-planar reconstruction is the best images to reveal the fissures of spondylolysis. It should be taken as routine item in MSCT examination for the patients with lower back pain. (authors)

  7. Pedicle streaking: A novel and simple aid in pedicle positioning in free tissue transfer

    Directory of Open Access Journals (Sweden)

    Aditya Aggarwal

    2015-01-01

    Full Text Available Introduction: The pedicle positioning in free tissue transfer is critical to its success. Long thin pedicles are especially prone to this complication where even a slight twist in the perforator can result in flap loss. Pedicles passing through the long tunnels are similarly at risk. Streaking the pedicle with methylene blue is a simple and safe method which increases the safety of free tissue transfer. Materials and Methods: Once the flap is islanded on the pedicle and the vascularity of the flap is confirmed, the pedicle is streaked with methylene blue dye at a distance of 6-7 mm. The streaking starts from the origin of the vessels and continued distally on to the under surface of flap to mark the complete course of the pedicle in alignment. The presence of streaking in some parts and not in rest indicates twist in the pedicle. Observation and Results: Four hundred and sixty five free flaps have been done at our centre in the last 5 years. The overall success rate of free flaps is 95.3% (22 free flap failures. There has not been a single case of pedicle twist leading to flap congestion and failure. Conclusion: This simple and novel method is very reliable for pedicle positioning avoiding any twist necessary for successful free tissue transfer.

  8. Adjacent Lumbar Disc Herniation after Lumbar Short Spinal Fusion

    Directory of Open Access Journals (Sweden)

    Koshi Ninomiya

    2014-01-01

    Full Text Available A 70-year-old outpatient presented with a chief complaint of sudden left leg motor weakness and sensory disturbance. He had undergone L4/5 posterior interbody fusion with L3–5 posterior fusions for spondylolisthesis 3 years prior, and the screws were removed 1 year later. He has been followed up for 3 years, and there had been no adjacent segment problems before this presentation. Lumbar magnetic resonance imaging (MRI showed a large L2/3 disc hernia descending to the L3/4 level. Compared to the initial MRI, this hernia occurred in an “intact” disc among multilevel severely degenerated discs. Right leg paresis and bladder dysfunction appeared a few days after admission. Microscopic lumbar disc herniotomy was performed. The right leg motor weakness improved just after the operation, but the moderate left leg motor weakness and difficulty in urination persisted.

  9. Unilateral lumbar spondylolysis on radiography and MRI: emphasis on morphologic differences according to involved segment.

    Science.gov (United States)

    Park, Ji Seon; Moon, Sung Kyoung; Jin, Wook; Ryu, Kyung Nam

    2010-01-01

    The objective of our study was to retrospectively compare the radiography and MRI findings of unilateral spondylolysis in the upper lumbar segment and in the lower lumbar segment and to consider how these radiologic findings can be applied in the diagnosis of unilateral spondylolysis. Thirty patients with unilateral lumbar spondylolysis were categorized into one of two groups according to the lumbar levels involved with pars interarticularis defects: group A (L1, L2, and L3) or group B (L4 and L5). On radiographs, we evaluated contour bulging of the affected pars interarticularis, reactive sclerosis in the contralateral pedicle, anterolisthesis of the involved vertebra, and deviation of the spinous process. On MRI, we assessed pseudoarticulation of the pars interarticularis defect, uneven distribution of posterior epidural fat, the interspinous distance between adjacent segments, facet and disk degeneration in adjacent segments, and other anomalous changes. Among the 63 patients with unilateral spondylolysis, the upper lumbar segment was involved in 29 and the lower lumbar segment, in 34. Group A often displayed contour bulging of the affected pars interarticularis, reactive sclerosis of the contralateral pedicle, and contralateral deviation of the spinous process, all of which were easily detectable on radiography. Group B frequently showed anterolisthesis, pseudoarticulation of the pars interarticularis defect, adjacent facet-disk degeneration, and other anomalous changes that were well observed on MRI. Unilateral lumbar spondylolysis displayed radiologic differences in morphology of the isthmic defect itself and in ancillary findings of the adjacent structures based on the segment involved. Recognition of different ancillary features of unilateral spondylolysis with the use of a feasible diagnostic tool can be helpful for the diagnosis of cases in which a direct sign of isthmic defect is equivocal.

  10. Adjacent Lumbar Disc Herniation after Lumbar Short Spinal Fusion

    OpenAIRE

    Ninomiya, Koshi; Iwatsuki, Koichi; Ohnishi, Yu-ichiro; Ohkawa, Toshika; Yoshimine, Toshiki

    2014-01-01

    A 70-year-old outpatient presented with a chief complaint of sudden left leg motor weakness and sensory disturbance. He had undergone L4/5 posterior interbody fusion with L3–5 posterior fusions for spondylolisthesis 3 years prior, and the screws were removed 1 year later. He has been followed up for 3 years, and there had been no adjacent segment problems before this presentation. Lumbar magnetic resonance imaging (MRI) showed a large L2/3 disc hernia descending to the L3/4 level. Compared to...

  11. Percutaneous endoscopic lumbar discectomy via contralateral approach: a technical case report.

    Science.gov (United States)

    Kim, Jin-Sung; Choi, Gun; Lee, Sang-Ho

    2011-08-01

    Technical case report. The authors report a new percutaneous endoscopic lumbar discectomy (PELD) technique for the treatment of lumbar disc herniation via a contralateral approach. When there are highly down-migrated lumbar disc herniation along just medial to pedicle and narrow ipsilateral intervertebral foramen, the conventional PELD is not easily accessible via ipsilateral transforaminal route. Five patients manifested gluteal and leg pain because of a soft disc herniation at the L4-L5 level. Transforaminal PELD via a contralateral approach was performed to remove the herniated fragment, achieving complete decompression of the nerve root. The symptom was relieved and the patient was discharged the next day. When a conventional transforaminal PELD is difficult because of some anatomical reasons, PELD via a contralateral route could be a good alternative option in selected cases.

  12. Minimally Invasive Direct Repair of Bilateral Lumbar Spine Pars Defects in Athletes

    Directory of Open Access Journals (Sweden)

    Gabriel A. Widi

    2013-01-01

    Full Text Available Spondylolysis of the lumbar spine has traditionally been treated using a variety of techniques ranging from conservative care to fusion. Direct repair of the defect may be utilized in young adult patients without significant disc degeneration and lumbar instability. We used minimally invasive techniques to place pars interarticularis screws with the use of an intraoperative CT scanner in three young adults, including two athletes. This technique is a modification of the original procedure in 1970 by Buck, and it offers the advantage of minimal muscle dissection and optimal screw trajectory. There were no intra- or postoperative complications. The detailed operative procedure and the postoperative course along with a brief review of pars interarticularis defect treatment are discussed.

  13. Treatment effect, postoperative complications, and their reasons in juvenile thoracic and lumbar spinal tuberculosis surgery.

    Science.gov (United States)

    He, Qing-Yi; Xu, Jian-Zhong; Zhou, Qiang; Luo, Fei; Hou, Tianyong; Zhang, Zehua

    2015-10-01

    Fifty-four juvenile cases under 18 years of age with thoracic and lumbar spinal tuberculosis underwent focus debridement, deformity correction, bone graft fusion, and internal fixation. The treatment effects, complications, and reasons were analyzed retrospectively. There were 54 juvenile cases under 18 years of age with thoracolumbar spinal tuberculosis. The average age was 9.2 years old, and the sample comprised 38 males and 16 females. The disease types included 28 thoracic cases, 17 thoracolumbar cases, and 9 lumbar cases. Nerve function was evaluated with the Frankel classification. Thirty-six cases were performed with focus debridement and deformity correction and were supported with allograft or autograft in mesh and fixed with pedicle screws from a posterior approach. Eight cases underwent a combined anterior and posterior surgical approach. Nine cases underwent osteotomy and deformity correction, and one case received focus debridement. The treatment effects, complications, and bone fusions were tracked for an average of 52 months. According to the Frankel classification, paralysis was improved from 3 cases of B, 8 cases of C, 18 cases of D, and 25 cases of E preoperatively. This improvement was found in 3 cases of C, 6 cases of D, and 45 cases of E at a final follow-up postoperatively. No nerve dysfunction was aggravated. VAS was improved from 7.8 ± 1.7 preoperatively to 3.2 ± 2.1 at final follow-up postoperatively. ODI was improved from 77.5 ± 17.3 preoperatively to 28.4 ± 15.9 at final follow-up postoperatively. Kyphosis Cobb angle improved from 62.2° ± 3.7° preoperatively to 37° ± 2.4° at final follow-up postoperatively. Both of these are significant improvements, and all bone grafts were fused. Complications related to the operation occurred in 31.5% (17/54) of cases. Six cases suffered postoperative aggravated kyphosis deformity, eight cases suffered proximal kyphosis deformity, one case suffered pedicle penetration

  14. Perioperative surgical complications and learning curve associated with minimally invasive transforaminal lumbar interbody fusion: a single-institute experience.

    Science.gov (United States)

    Park, Yung; Lee, Soo Bin; Seok, Sang Ok; Jo, Byung Woo; Ha, Joong Won

    2015-03-01

    As surgical complications tend to occur more frequently in the beginning stages of a surgeon's career, knowledge of perioperative complications is important to perform a safe procedure, especially if the surgeon is a novice. We sought to identify and describe perioperative complications and their management in connection with minimally invasive transforaminal lumbar interbody fusion (TLIF). We performed a retrospective chart review of our first 124 patients who underwent minimally invasive TLIF. The primary outcome measure was adverse events during the perioperative period, including neurovascular injury, implant-related complications, and wound infection. Pseudarthroses and adjacent segment pathologies were not included in this review. Adverse events that were not specifically related to spinal surgery and did not affect recovery were also excluded. Perioperative complications occurred in 9% of patients (11/124); including three cases of temporary postoperative neuralgia, two deep wound infections, two pedicle screw misplacements, two cage migrations, one dural tear, and one grafted bone extrusion. No neurologic deficits were reported. Eight complications occurred in the first one-third of the series and only 3 complications occurred in the last two-thirds of the series. Additional surgeries were performed in 6% of patients (7/124); including four reoperations (two for cage migrations, one for a misplaced screw, and one for an extruded graft bone fragment) and three hardware removals (one for a misplaced screw and two for infected cages). We found perioperative complications occurred more often in the early period of a surgeon's experience with minimally invasive TLIF. Implant-related complications were common and successfully managed by additional surgeries in this series. We suggest greater caution should be exercised to avoid the potential complications, especially when surgeon is a novice to this procedure.

  15. Does Lordotic Angle of Cage Determine Lumbar Lordosis in Lumbar Interbody Fusion?

    Science.gov (United States)

    Hong, Taek-Ho; Cho, Kyu-Jung; Kim, Young-Tae; Park, Jae-Woo; Seo, Beom-Ho; Kim, Nak-Chul

    2017-07-01

    Retrospective, radiological analysis. To determine that 15° lordotic angle cages create higher lumbar lordosis in open transforaminal lumbar interbody fusion (TLIF) than 4° and 8° cages. Restoration of lumbar lordosis is important to obtain good outcome after lumbar fusion surgery. Various shapes and angles of cages in interbody fusion have been used; however, it is not proved that lordotic angle of cages determine lumbar lordosis. Sixty-seven patients were evaluated after TLIF using 15° cages and screw instrumentation. For comparison, TLIF using 4° lordotic angle cages in 65 patients and 8° cages in 49 patients were analyzed. Lumbar lordosis angles, segmental lordosis angles, disc height, and bony union rate were measured on the radiographs. The lumbar lordosis was 31.1° preoperatively, improved to 42.9° postoperatively, and decreased to 36.4° at the last follow-up in the 15° group. It was 35.8° before surgery, corrected to 41.5° after surgery, and changed to 33.6° at the last follow-up in the 4° group. In the 8° group, it was 32.7° preoperatively, improved to 39.1° postoperatively, and decreased to 34.5° at the last follow-up. These changes showed statistical significances (P lordosis at L4-5 was 6.6° before surgery, 13.1° after surgery, and 9.8° at the last follow-up in the 15° group. It was 6.9°, 9.5°, and 6.2° in the 4° group and 6.7°, 9.8°, and 8.1° in the 8° group, respectively (P lordosis after TLIF. Cages with sufficient lordotic angle showed better restoration of lumbar lordosis and prevention of loss of correction. 4.

  16. Direct repair surgery with screw fixation for young patients with lumbar spondylolysis: patient-reported outcomes and fusion rate in a prospective interventional study.

    Science.gov (United States)

    Lee, Gun Woo; Lee, Sun-Mi; Suh, Bo-Gun

    2015-02-15

    Prospective interventional study. To thoroughly investigate the therapeutic outcomes of direct repair (DR) for young patients with lumbar spondylolysis. DR surgery with screw fixation for a pars defect of lumbar spondylolysis is considered a notable surgical option. However, prior studies do not provide clear information on the significance of DR and its outcomes in young patients with lumbar spondylolysis because most previous studies in this area were conducted with spondylolysis patients of all ages and with low-quality study designs that were retrospective in design and had a small sample size and short follow-up time. A total of 47 young patients with lumbar spine spondylolysis who were surgically treated with DR surgery and followed up for 1 year after surgery were enrolled in this study. The primary outcome was degree of pain assessed by visual analogue scale, which separately recorded pain intensity and pain frequency. Secondary outcomes included (1) patient satisfaction, (2) clinical outcomes based on Oswestry Disability Index score and a 12-item short form health survey, (3) fusion rate of pars defect based on computed tomographic scans, and (4) surgery-related complications. The degree of lower back pain (intensity and frequency) significantly improved at final follow-up compared with preoperative level. However, 6 patients (13%) had no significant improvement, and pain frequency tended to worsen 6 months after the operation. Only 25 patients (53%) were satisfied with DR surgery. One-year postoperative clinical outcomes (Oswestry Disability Index and 12-item short form health survey) significantly improved compared with preoperative levels, but the 2 scores also tended to decrease after 6 months. The union rate of the pars defect was 55% (26/47). There was no significant difference in clinical outcomes between fusion group and nonunion group of the pars defect at the final follow-up. Two patients (4%) experienced surgery-related complications. The

  17. Construction and accuracy assessment of patient-specific biocompatible drill template for cervical anterior transpedicular screw (ATPS insertion: an in vitro study.

    Directory of Open Access Journals (Sweden)

    Maoqing Fu

    Full Text Available BACKGROUND: With the properties of three-column fixation and anterior-approach-only procedure, anterior transpedicular screw (ATPS is ideal for severe multilevel traumatic cervical instabilities. However, the accurate insertion of ATPS remains challenging. Here we constructed a patient-specific biocompatible drill template and evaluated its accuracy in assisting ATPS insertion. METHODS: After ethical approval, 24 formalin-preserved cervical vertebrae (C2-C7 were CT scanned. 3D reconstruction models of cervical vertebra were obtained with 2-mm-diameter virtual pin tracts at the central pedicles. The 3D models were used for rapid prototyping (RP printing. A 2-mm-diameter Kirschner wire was then inserted into the pin tract of the RP model before polymethylmethacrylate was used to construct the patient-specific biocompatible drill template. After removal of the anterior soft tissue, a 2-mm-diameter Kirschner wire was inserted into the cervical pedicle with the assistance of drill template. Cadaveric cervical spines with pin tracts were subsequently scanned using the same CT scanner. A 3D reconstruction was performed of the scanned spines to get 3D models of the vertebrae containing the actual pin tracts. The deviations were calculated between 3D models with virtual and actual pin tracts at the middle point of the cervical pedicle. 3D models of 3.5 mm-diameter screws were used in simulated insertion to grade the screw positions. FINDINGS: The patient-specific biocompatible drill template was constructed to assist ATPS insertion successfully. There were no significant differences between medial/lateral deviations (P = 0.797 or between superior/inferior deviations (P = 0.741. The absolute deviation values were 0.82±0.75 mm and 1.10±0.96 mm in axial and sagittal planes, respectively. In the simulated insertion, the screws in non-critical position were 44/48 (91.7%. CONCLUSIONS: The patient-specific drill template is biocompatible, easy

  18. CT morphometric analysis to determine the anatomical basis for the use of transpedicular screws during reconstruction and fixations of anterior cervical vertebrae.

    Directory of Open Access Journals (Sweden)

    Chun Chen

    Full Text Available BACKGROUND: Accurate placement of pedicle screw during Anterior Transpedicular Screw fixation (ATPS in cervical spine depends on accurate anatomical knowledge of the vertebrae. However, little is known of the morphometric characteristics of cervical vertebrae in Chinese population. METHODS: Three-dimensional reconstructions of CT images were performed for 80 cases. The anatomic data and screw fixation parameters for ATPS fixation were measured using the Mimics software. FINDINGS: The overall mean OPW, OPH and PAL ranged from 5.81 to 7.49 mm, 7.77 to 8.69 mm, and 33.40 to 31.13 mm separately, and SPA was 93.54 to 109.36 degrees from C3 to C6, 104.99 degrees at C7, whereas, 49.00 to 32.26 degrees from C4 to C7, 46.79 degrees at C3 (TPA. Dl/rSIP had an increasing trend away from upper endplate with mean value from 1.87 to 5.83 mm. Dl/rTIP was located at the lateral portion of the anterior cortex of vertebrae for C3 to C5 and ipsilateral for C6 to C7 with mean value from -2.70 to -3.00 mm, and 0.17 to 3.18 mm. The entrance points for pedicular screw insertion for C3 to C5 and C6 to C7 were recommended -2∼-3 mm and 0-4 mm from the median sagittal plane, respectively, 1-4 mm and 5-6 mm from the upper endplate, with TPA being 46.79-49.00 degrees and 40.89-32.26 degrees, respectively, and SPA being 93.54-106.69 degrees and 109.36-104.99 degrees, respectively. The pedicle screw insertion diameter was recommended 3.5 mm (C3 and C4, 4.0 mm (C5 to C7, and the pedicle axial length was 21-24 mm for C3 to C7 for both genders. However, the ATPS insertion in C3 should be individualized given its relatively small anatomical dimensions. CONCLUSIONS: The data provided a morphometric basis for the ATPS fixation technique in lower cervical fixation. It will help in preoperative planning and execution of this surgery.

  19. [Use of pedicle percutaneous cemented screws in the management of patients with poor bone stock].

    Science.gov (United States)

    Pesenti, S; Graillon, T; Mansouri, N; Adetchessi, T; Tropiano, P; Blondel, B; Fuentes, S

    2016-12-01

    Management of patients with poor bone stock remains difficult due to the risks of mechanical complications such as screws pullouts. At the same time, development of minimal invasive spinal techniques using a percutaneous approach is greatly adapted to these fragile patients with a reduction in operative time and complications. The aim of this study was to report our experience with cemented percutaneous screws in the management of patients with a poor bone stock. Thirty-five patients were included in this retrospective study. In each case, a percutaneous osteosynthesis using cemented screws was performed. Indications were osteoporotic fractures, metastasis or fractures on ankylosing spine. Depending on radiologic findings, short or long constructs (2 levels above and below) were performed and an anterior column support (kyphoplasty or anterior approach) was added. Evaluation of patients was based on pre and postoperative CT-scans associated with clinical follow-up with a minimum of 6 months. Eleven men and 24 women with a mean age of 73 years [60-87] were included in the study. Surgical indication was related to an osteoporotic fracture in 20 cases, a metastasis in 13 cases and a fracture on ankylosing spine in the last 2 cases. Most of the fractures were located between T10 and L2 and a long construct was performed in 22 cases. Percutaneous kyphoplasty was added in 24 cases and a complementary anterior approach in 3 cases. Average operative time was 86minutes [61-110] and blood loss was estimated as minor in all the cases. In the entire series, average volume of cement injected was 1.8 cc/screw. One patient underwent a major complication with a vascular leakage responsible for a cement pulmonary embolism. With a 9 months average follow-up [6-20], no cases of infection or mechanical complication was reported. Minimal invasive spinal techniques are greatly adapted to the management of fragile patients. The use of percutaneous cemented screws is, in our experience

  20. Results of triple muscle (sartorius, tensor fascia latae and part of gluteus medius pedicle bone grafting in neglected femoral neck fracture in physiologically active patients

    Directory of Open Access Journals (Sweden)

    Pankaj Kumar Mishra

    2014-01-01

    Full Text Available Background: Femoral neck fractures are notorious for complications like avascular necrosis and nonunion. In developing countries, various factors such as illiteracy, low socioeconomic status, ignorance are responsible for the delay in surgery. Neglected fracture neck femur always poses a formidable challenge. The purpose of this study was to evaluate the results of triple muscle pedicle bone grafting using sartorius, tensor fasciae latae and part of gluteus medius in neglected femoral neck fracture. Materials and Methods: This is a retrospective study with medical record of 50 patients, who were operated by open reduction, internal fixation along with muscle pedicle bone grafting by the anterior approach. After open reduction, two to three cancellous screws (6.5 mm were used for internal fixation in all cases. A bony chunk of the whole anterior superior iliac spine of 1 cm thickness, 1 cm width and 4.5 cm length, taken from the iliac crest comprised of muscle pedicle of sartorius, tensor fascia latae and part of gluteus medius. Then the graft with all three muscles mobilized and put in the trough made over the anterior or anterosuperior aspect of the femoral head. The graft was fixed with one or two 4.5 mm self-tapping cortical screw in anterior to posterior direction. Results: 14 patients were lost to followup. The results were based on 36 patients. We observed that in our series, there was union in 34, out of 36 (94.4% patients. All patients were within the age group of 15-51 years (average 38 years with displaced neglected femoral neck fracture of ≥30 days. Mean time taken for full clinicoradiological union was 14 weeks (range-10-24 weeks. Conclusion: Triple muscle pedicle bone grafting gives satisfactory results for neglected femoral neck fracture in physiologically active patients.

  1. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  2. MORPHOMETRY OF THE PEDICLE OF FIRST SACRAL VERTEBRAE AND ITS APPLICATION IN POSTERIOR TRANSPEDICULAR SCREW FIXATION. Morfometría del pedículo de la primera vértebra sacra y su aplicación en la fijación posterior con tornillo transpedicular

    Directory of Open Access Journals (Sweden)

    Mangala M Pai

    2016-03-01

    were 27.2±4.0 mms and 23.9±3.7 mms for the male and female respectively. The anteroposterior width of S1 pedicle was 7.5± 1.3 mms, 7.5± 1.7 mms in males and females respectively. The anteroposterior distances of S1, from the sacral promontory to the spinous process of S1 were 52.9± 5.2 mms and 50.4± 6.8 mms respectively for the male and female genders. The present study observed that the mean S1 pedicle length and the cephalocaudal height were higher (p<0.05 for the males than that of females. The data (male vs female were not found statistically different (p>0.05, with respect to the anteroposterior width of the S1 pedicle and the anteroposterior distances of S1 from the sacral promontory to the spinous process of S1. The present study has provided important morphometric data onto the pedicle of the first sacral vertebrae, from the anatomical samples of the South Indian population. The knowledge of pedicle diameters of S1 is crucial to the safe placement of screws in the posterior transpedicular screw fixation.

  3. Nilai Rerata Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio Vascular Pedicle-Thoracic Ratio Orang Dewasa Normal Indonesia Studi di RS dr. Cipto Mangunkusomo

    Directory of Open Access Journals (Sweden)

    Rommy Zunera

    2016-03-01

    Full Text Available Vascular pedicle width (VPW adalah jarak tepi luar vena kava superior ke tepi luar arteri subklavia kiri. Pemeriksaan VPW di foto toraks bersifat non-invasif, cepat dan mudah untuk memprediksi hipervolemia.Penelitian ini bertujuan untuk mengetahui rerata nilai VPW orang dewasa normal Indonesia. VPW diukurdengan dua metode: pertama pengukuran VPW tunggal yang akurasinya terbatas di foto toraks digital karenarelatif tidak dipengaruhi faktor magnifikasi. Metode kedua untuk foto toraks nondigital yaitu pengukuranrasio:vascular pedicle-cardiac ratio (VPCR dan vascular pedicle-thoracic ratio (VPTR. Pengukuran serupadilakukan terhadap  topogram CT scan toraks AP terlentang dan CT scan toraks lalu dibandingkan akurasipengukuran di topogram dengan CT scan  toraks sebagai standar baku. Sampel terdiri atas 104 foto toraksPA subyek normal dan 103 CT scan  toraks subyek terpilih. Pada pemeriksaan toraks PA didapatkan rerata VPW 48,0±5,5mm, rerata VPCR 40,3±4,6%, dan rerata VPTR 17,2±1,7%. Pada pemeriksaan topogram CTscan didapatkan rerata VPW 50,3±6,2mm, rerata VPTR 45±5,1%, dan rerata VPTR 19,8±2,5%. Rerata VPWpada CT scan toraks 50,4±6,1mm. Pengukuran di foto toraks AP 10% lebih besar dibandingkan pada fototoraks PA dan pengukuranVPW di foto toraks terbukti memiliki akurasi  tinggi. Kata kunci: fototoraks, vascular pedicle width, vascular pedicle-cardiac ratio, vascular pedicle-thoracic ratio, hipervolemia.   The Mean Value of Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio,Vascular Pedicle-Thoracic Ratio of Normal Indonesian Adult Study In dr. Cipto Mangunkusomo Hospital Abstract Vascular pedicle width (VPW is the distance, from a perpendicular line at the takeoff point of the left subclavian artery off the aorta to the point at which the superior vena cava. Measurement of VPW on chestx-ray is relatively non-invasive, fast and easy technique as  hypervolemia predictor. The purpose of thisstudy is to know the mean VPW value of normal

  4. [Enlargement in managment of lumbar spinal stenosis].

    Science.gov (United States)

    Steib, J P; Averous, C; Brinckert, D; Lang, G

    1996-05-01

    flexion, obesity or quite simply overuse, involve an increase in the lumbar lordosis. The posterior articulations are worn out and the disc gets damaged by shear forces. The disc space becomes shorter with a bulging disc, and the inferior articular process of the superior vertebra goes down. This is responsible of a loss of lordosis. For restoring the sagittal balance the patient needs more extension of the spine. Above and below the considered level the degenerative disease carries on extending to the whole spine. At the level considered, because of local extension, the inferior facet moves forward, the disc bulges, the ligamentum flavum is shortened and the stenosis is increased. This situation is improved by local kyphosis: the inferior facet moves backward, the disc and the ligamentum flavum are stretched with a quite normal posterior disc height and most often there is no more stenosis. Myelograms show this very well with a quite normal appearance lying, clear compression standing, worse in extension and improved, indeed disappeared in flexion. CT scan and MRI don't show that because they are done lying. The expression of the clinical situation is the same, mute lying and maximum standing with restriction of walking. For us lumbar stenosis is operated with lumbar reconstruction without opening the canal. The patient is in moderate kyphosis on the operating table. Pedicle screws rotated to match a bent rod allow reduction of the spine. The posterior disc height is respected and not distracted, and the anterior part of the disc is stretched in lordosis. The inferior facet is cut for the arthrodesis and no longer compresses the dura. The canal is well enlarged and the lumbar segment in lordosis is the best protection of the adjacent levels at follow-up. This behaviour responds to the same analysis as the ≪recalibrage≫ (enlargement). The mobile segment is damaged by the degenerative disease, the stenosis is a consequence of this damage. It's logical to treat the

  5. Combined anterior C2-C3 fusion and C2 pedicle screw fixation for the treatment of unstable hangman's fracture: a contrast to anterior approach only.

    Science.gov (United States)

    Xie, Ning; Khoo, Larry T; Yuan, Wen; Ye, Xiao-Jian; Chen, De-Yu; Xiao, Jian-Ru; Ni, Bin

    2010-03-15

    A retrospective clinical study was used to evaluate the effect of a new surgical treatment of the hangman's fractures. To determine the treatment efficacy of combined anterior C2-C3 reduction and fusion and posterior compressive C2 pedicle screw fixation for the management of unstable hangman's fractures. The classification of hangman's fractures as proposed by Levine-Edwards was used to classify and guide the treatment of these injuries. Most of these fractures respond to a variety of conservative therapies, but recently, earlier surgery has been increasingly advocated by authors from several countries for the rapid stabilization of these fractures. If surgery is indicated, an anterior approach using a C2-C3 reduction and fusion is preferred usually. Another well-accepted surgical method is the direct transpedicular osteosynthesis by the dorsal approach. However, there was rare report of the combined use of these 2 techniques. A group of 45 surgical patients were all diagnosed with radiograph, magnetic resonance imaging (MRI), and 3D CT scans. Initial and final radiographs were measured for anterior translation and angulation of the C2-C3 complex. Initial external skull traction with extension was used in all patients after admission to reduce the fracture. Then an anterior C2-C3 discectomy followed by an interbody fusion and locking plate fixation was performed. Intraoperative reduction was confirmed by fluoroscopic control. About 29 patients therefore received anterior surgeries only since satisfactory reduction was achieved during the procedure. For the 16 patients who had persistent large residual gaps after the anterior procedure, additional same stage posterior C2 compressive pedicle screws were placed. Clinical and radiologic comparisons were performed in these 2 groups. The follow-up ranged from 24 to 54 months, with an average 33.6 months. There was radiographic evidence of continuity of the fracture and the bone graft seen at 4.7 months on average. Neck

  6. The shape of the human lumbar vertebral canal A forma do canal vertebral lombar humano

    Directory of Open Access Journals (Sweden)

    Edmundo Zarzur

    1996-09-01

    Full Text Available Literature on the anatomy of the human vertebral column characterizes the shape of the lumbar vertebral canal as triangular. The purpose of the present study was to determine the precise shape of the lumbar vertebral canal. Ten lumbar vertebral columns of adult male cadavers were dissected. Two transverse sections were performed in the third lumbar vertebra. One section was performed at the level of the lower border of the ligamenta flava, and the other section was performed at the level of the pedicles. The shape of the lumbar vertebral canal at the level of the pedicles tends to be oval or circular, whereas the shape of the lumbar vertebral canal at the level of the lower border of the ligamenta flava is triangular. Thus, the shape of the human lumbar vertebral canal is not exclusively triangular, as reported in the literature. It is related to the level of the transversal section performed on the lumbar vertebra. This finding should be taken into consideration among factors involved in the spread of solutions introduced into the epidural space.A literatura sobre a anatomia da coluna vertebral descreve como sendo triangular o formato do canal vertebral na região lombar. O objetivo deste estudo é determinar a real forma do canal da coluna vertebral lombar.Dez colunas vertebrais de cadáveres de homens adultos foram dissecadas. Dois cortes transversais foram executados na terceira vértebra lombar. Um corte foi feito no nível das bordas inferiores de dois ligamentos amarelos vizinhos e o outro corte foi transversal, no nível dos pedículos. A forma do canal vertebral variou: no nível dos pedículos ela tende a ser oval ou circular e junto às bordas inferiores dos ligamentos amarelos passa a ser triangular. Portanto, a forma do canal vertebral lombar não é somente triangular; ela depende do nível em que se faz o corte transversal da vértebra. Estes achados devem ser levados em consideração entre os fatores envolvidos na difusão das

  7. Posterior all-pedicle screw instrumentation combined with multiple chevron and concave rib osteotomies in the treatment of adolescent congenital kyphoscoliosis.

    Science.gov (United States)

    Ayvaz, Mehmet; Olgun, Z Deniz; Demirkiran, H Gokhan; Alanay, Ahmet; Yazici, Muharrem

    2014-01-01

    Congenital kyphoscoliosis is a disorder that often requires surgical treatment. Although many methods of surgical treatment exist, posterior-only vertebral column resection with instrumentation and fusion seem to have become the gold standard for very severe and very rigid curves. Multiple chevron and concave rib osteotomies have been previously reported to be effective in the treatment of neglected severe idiopathic curves. We hypothesized that this method may also be used successfully in the treatment of congenital kyphoscoliosis. To evaluate the effectiveness and safety of multiple chevron osteotomies combined with concave rib osteotomy and posterior pedicle screw instrumentation. Retrospective chart review in the spine service of a large university hospital. Adolescent patients undergoing a specific surgical treatment for the indication of rigid congenital kyphoscoliotic deformity. Radiographic images were used for the measurement of deformity correction. The Turkish version of the Scoliosis Research Society 22 (SRS-22) Patient Questionnaire has been used as a clinical outcome measure in the patient population. A retrospective chart review was performed. Patients admitted to Hacettepe Hospital Spine Center during the period of 2005 to 2009 were included. Criteria for inclusion were as follows: adolescent age group (10-16 years); congenital kyphoscoliosis; formation and/or segmentation defect of at least two vertebral motion segments; surgical treatment of deformity by posterior all-pedicle screw instrumentation, multiple chevron osteotomies, and multiple concave rib osteotomies; follow-up of at least 24 months; and a complete set of preoperative, postoperative, and follow-up standing posteroanterior and lateral full spinal radiographs. The patients' hospital records and X-rays were reviewed. Duration of surgery, intraoperative blood loss, postoperative transfusion requirements, postoperative stay in postanesthesia care unit (PACU), time of hospitalization, and

  8. Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

    Science.gov (United States)

    Işik, Hasan Serdar; Sandal, Evren; Çağli, Sedat

    2017-06-14

    In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016, were analyzed. 28 patients, who had pre and post-operative images, follow-up forms and who were followed for at least one year, were analyzed. Preoperative clinical and radiological records, preoperative observations, postoperative complications, and clinical responses were evaluated. The average age of 28 patients (F:13 M:19) was 44.7 (21-73). Fixation was performed with C1-C2 screw-rod system on the basis of the following diagnoses; type 2 odontoid fracture (16), basilar invagination (5), C1-C2 instability (5), and atlantoaxial subluxation secondary to rheumatoid arthritis (2). Lateral mass screws were inserted at C1 segment. C2 screws inserted were bilateral pedicle in 12 cases, bilateral pars in 4, bilateral laminar in 8 and one side pars, one side laminar in 4 cases. There was no screw malposition. Neither implant failure nor recurrent instability was observed during follow-up. Significant clinical improvement was reported according to the assessments done with JOA and VAS scores. C1-C2 screw fixation is regarded as a more successful and safe method than other fixation methods in surgical treatment of atlantoaxial instability considering complications, success in reduction, fusion and fixation strength. C2 laminar screw technique is as successful as the other alternatives in fixation and fusion.

  9. The freestyle pedicle perforator flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Jackson, Ian T; Westvik, Tormod S

    2015-01-01

    BACKGROUND: Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally...... not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. METHODS: We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled...... perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects...

  10. Pedicled perforator flaps

    DEFF Research Database (Denmark)

    Demirtas, Yener; Ozturk, Nuray; Kelahmetoglu, Osman

    2009-01-01

    Described in this study is a surgical concept that supports the "consider and use a pedicled perforator flap whenever possible and indicated" approach to reconstruct a particular skin defect. The operation is entirely free-style; the only principle is to obtain a pedicled perforator flap...... to reconstruct the defect. The perforators are marked with a hand-held Doppler probe and multiple flaps are designed. The appropriate flap is elevated after identifying the perforator(s). Dissection of the perforator(s) or complete incision of the flap margins are not mandatory if the flap is mobilized...... adequately to cover the defect. Defects measuring 3 x 3 cm up to 20 x 20 cm at diverse locations were successfully reconstructed in 20 of 21 patients with 26 flaps. Pedicled perforator flaps offer us reliable and satisfactory results of reconstruction at different anatomic territories of the body. It sounds...

  11. Ti-24Nb-4Zr-8Sn Alloy Pedicle Screw Improves Internal Vertebral Fixation by Reducing Stress-Shielding Effects in a Porcine Model.

    Science.gov (United States)

    Qu, Yang; Zheng, Shuang; Dong, Rongpeng; Kang, Mingyang; Zhou, Haohan; Zhao, Dezhi; Zhao, Jianwu

    2018-01-01

    To ensure the biomechanical properties of Ti-24Nb-4Zr-8Sn, stress-shielding effects were compared between Ti-24Nb-4Zr-8Sn and Ti-6Al-4V fixation by using a porcine model. Twelve thoracolumbar spines (T12-L5) of 12-month-old male pigs were randomly divided into two groups: Ti-24Nb-4Zr-8Sn (EG, n = 6) and Ti-6Al-4V (RG, n = 6) fixation. Pedicle screw was fixed at the outer edge of L4-5 vertebral holes. Fourteen measuring points were selected on the front of transverse process and middle and posterior of L4-5 vertebra. Electronic universal testing machine was used to measure the strain resistance of measuring points after forward and backward flexion loading of 150 N. Meanwhile, stress resistance was compared between both groups. The strain and stress resistance of measurement points 1, 2, 5, 6, 9, and 10-14 in Ti-24Nb-4Zr-8Sn fixation was lower than that of Ti-6Al-4V fixation after forward and backward flexion loading ( P Ti-24Nb-4Zr-8Sn fixation than that of Ti-6Al-4V fixation ( P Ti-24Nb-4Zr-8Sn internal fixation were less than that of Ti-6Al-4V internal fixation. These results suggest that Ti-24Nb-4Zr-8Sn elastic fixation has more biomechanical goals than conventional Ti-6Al-4V internal fixation by reducing stress-shielding effects.

  12. Direct lateral approach to lumbar fusion is a biomechanically equivalent alternative to the anterior approach: an in vitro study.

    Science.gov (United States)

    Laws, Cory J; Coughlin, Dezba G; Lotz, Jeffrey C; Serhan, Hassan A; Hu, Serena S

    2012-05-01

    A human cadaveric biomechanical study of lumbar mobility before and after fusion and with or without supplemental instrumentation for 5 instrumentation configurations. To determine the biomechanical differences between anterior lumbar interbody fusion (ALIF) and direct lateral interbody fusion (DLIF) with and without supplementary instrumentation. Some prior studies have compared various surgical approaches using the same interbody device whereas others have investigated the stabilizing effect of supplemental instrumentation. No published studies have performed a side-by-side comparison of standard and minimally invasive techniques with and without supplemental instrumentation. Eight human lumbosacral specimens (16 motion segments) were tested in each of the 5 following configurations: (1) intact, (2) with ALIF or DLIF cage, (3) with cage plus stabilizing plate, (4) with cage plus unilateral pedicle screw fixation (PSF), and (5) with cage plus bilateral PSF. Pure moments were applied to induce specimen flexion, extension, lateral bending, and axial rotation. Three-dimensional kinematic responses were measured and used to calculate range of motion, stiffness, and neutral zone. Compared to the intact state, DLIF significantly reduced range of motion in flexion, extension, and lateral bending (P = 0.0117, P = 0.0015, P = 0.0031). Supplemental instrumentation significantly increased fused-specimen stiffness for both DLIF and ALIF groups. For the ALIF group, bilateral PSF increased stiffness relative to stand-alone cage by 455% in flexion and 317% in lateral bending (P = 0.0009 and P < 0.0001). The plate increased ALIF group stiffness by 211% in extension and 256% in axial rotation (P = 0.0467 and P = 0.0303). For the DLIF group, bilateral PSF increased stiffness by 350% in flexion and 222% in extension (P < 0.0001 and P = 0.0008). No differences were observed between ALIF and DLIF groups supplemented with bilateral PSF. Our data support that the direct lateral approach

  13. Muscle gap approach under a minimally invasive channel technique for treating long segmental lumbar spinal stenosis: A retrospective study.

    Science.gov (United States)

    Bin, Yang; De Cheng, Wang; Wei, Wang Zong; Hui, Li

    2017-08-01

    This study aimed to compare the efficacy of muscle gap approach under a minimally invasive channel surgical technique with the traditional median approach.In the Orthopedics Department of Traditional Chinese and Western Medicine Hospital, Tongzhou District, Beijing, 68 cases of lumbar spinal canal stenosis underwent surgery using the muscle gap approach under a minimally invasive channel technique and a median approach between September 2013 and February 2016. Both approaches adopted lumbar spinal canal decompression, intervertebral disk removal, cage implantation, and pedicle screw fixation. The operation time, bleeding volume, postoperative drainage volume, and preoperative and postoperative visual analog scale (VAS) score and Japanese Orthopedics Association score (JOA) were compared between the 2 groups.All patients were followed up for more than 1 year. No significant difference between the 2 groups was found with respect to age, gender, surgical segments. No diversity was noted in the operation time, intraoperative bleeding volume, preoperative and 1 month after the operation VAS score, preoperative and 1 month after the operation JOA score, and 6 months after the operation JOA score between 2 groups (P > .05). The amount of postoperative wound drainage (260.90 ± 160 mL vs 447.80 ± 183.60 mL, P gap approach group than in the median approach group (P gap approach under a minimally invasive channel group, the average drainage volume was reduced by 187 mL, and the average VAS score 6 months after the operation was reduced by an average of 0.48.The muscle gap approach under a minimally invasive channel technique is a feasible method to treat long segmental lumbar spinal canal stenosis. It retains the integrity of the posterior spine complex to the greatest extent, so as to reduce the adjacent spinal segmental degeneration and soft tissue trauma. Satisfactory short-term and long-term clinical results were obtained.

  14. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    Science.gov (United States)

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  15. Anatomic considerations for C2 pedicle screw placement: the use of computerized tomography measurements Consideraciones anatómicas de la cocalización de los tornillos pediculares en C2: uitlización de las medidas de la tomografia computadorizada Considerações anatômicas sobre a localização dos parafusos pediculares em C2: utilização das medidas da tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Adebukoa Onibokun

    2009-03-01

    Full Text Available OBJECTIVE: more detailed anatomical knowledge of the C2 pedicle is required to optimize and minimize the risk of screw placement. The aim of this study was to evaluate the linear and angular dimensions of the true C2 pedicle using axial CT. METHODS: ninety three patients (47 males, 46 females mean age 48 years who had cervical spinal CT imaging performed were evaluated for this study. Axial images of the C2 pedicle were selected and the following pedicle parameters were determined: pedicle width (PW, the mediolateral diameter of the pedicle isthmus, perpendicular to the pedicle axis and pedicle transverse angle (PTA, that is, the angle between the pedicle axis and the midline of the vertebral body. RESULTS: the overall mean pedicle width was 5.8 1.2mm. The mean pedicle width in males (6.01.3mm was greater than that in the female subjects (5.6 1.1mm. This difference was not found to be statistically significant (p=.6790. The overall mean pedicle transverse angle was 43.93.9 degrees. The mean PTA in males was 43.23.8 degrees, while that in females was 44.73.7 degrees. CONCLUSION: preoperative planning is absolutely mandatory, particularly in determining not only screw trajectory, but in analyzing individual patient anatomy and reception to a C2 pedicle screw.OBJETIVO: el conocimiento detallado de las características anatómicas del pedículo de C2 es necesario para minimizar los riesgos relacionados con la colocación de los tornillos. El objetivo del estudio fue evaluar las medidas lineares y angulares del eje axial verdadero del pedículo de C2 utilizando la tomografía computadorizada. MÉTODOS: fueron utilizadas tomografías computadorizadas axiales de 93 pacientes (47 del sexo masculino y 46 del sexo femenino con promedio de edad de 48 años. Las imágenes axiales del pedículo de C2 fueron seleccionadas para el estudio y los parámetros estudiados fueron: Ancho del pedículo (diámetro mediolateral del istmo del pedículo perpendicular al

  16. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality.

    Science.gov (United States)

    Martín-Fernández, M; López-Herradón, A; Piñera, A R; Tomé-Bermejo, F; Duart, J M; Vlad, M D; Rodríguez-Arguisjuela, M G; Alvarez-Galovich, L

    2017-08-01

    Dramatic increases in the average life expectancy have led to increases in the variety of degenerative changes and deformities observed in the aging spine. The elderly population can present challenges for spine surgeons, not only because of increased comorbidities, but also because of the quality of their bones. Pedicle screws are the implants used most commonly in spinal surgery for fixation, but their efficacy depends directly on bone quality. Although polymethyl methacrylate (PMMA)-augmented screws represent an alternative for patients with osteoporotic vertebrae, their use has raised some concerns because of the possible association between cement leakages (CLs) and other morbidities. To analyze potential complications related to the use of cement-augmented screws for spinal fusion and to investigate the effectiveness of using these screws in the treatment of patients with low bone quality. A retrospective single-center study. This study included 313 consecutive patients who underwent spinal fusion using a total of 1,780 cement-augmented screws. We analyzed potential complications related to the use of cement-augmented screws, including CL, vascular injury, infection, screw extraction problems, revision surgery, and instrument failure. There are no financial conflicts of interest to report. A total of 1,043 vertebrae were instrumented. Cement leakage was observed in 650 vertebrae (62.3%). There were no major clinical complications related to CL, but two patients (0.6%) had radicular pain related to CL at the S1 foramina. Of the 13 patients (4.1%) who developed deep infections requiring surgical debridement, two with chronic infections had possible spondylitis that required instrument removal. All patients responded well to antibiotic therapy. Revision surgery was performed in 56 patients (17.9%), most of whom had long construction. A total of 180 screws were removed as a result of revision. There were no problems with screw extraction. These results

  17. Minimally invasive lateral trans-psoas approach for tuberculosis of lumbar spine

    Directory of Open Access Journals (Sweden)

    Nitin Garg

    2014-01-01

    Full Text Available Anterior, posterolateral and posterior approaches are used for managing lumbar tuberculosis. Minimally invasive methods are being used increasingly for various disorders of the spine. This report presents the utility of lateral trans-psoas approach to the lumbar spine (LS using minimal access techniques, also known as direct lateral lumbar interbody fusion in 2 cases with tuberculosis of LS. Two patients with tuberculosis at L2-3 and L4-5 presented with back pain. Both had destruction and deformity of the vertebral body. The whole procedure comprising debridement and placement of iliac crest graft was performed using tubular retractors and was augmented by posterior fixation using percutaneous transpedicular screws. Both patients recovered well with no significant procedure related morbidity. Post-operative computed tomography scans showed appropriate position of the graft and instrumentation. At follow-up, both patients are ambulant with no progression of the deformity. Minimal access direct lateral transpsoas approach can be used for debridement and reconstruction of ventral column in tuberculous of Lumbar spine. This paper highlights the growing applications of minimal access surgery for spine.

  18. Evaluation of an omental pedicle extension technique in the dog.

    Science.gov (United States)

    Ross, W E; Pardo, A D

    1993-01-01

    A two-step omental pedicle extension technique was performed on 10 dogs. Step 1 of the pedicle extension involved release of the dorsal leaf of the omentum from its pancreatic attachment, whereas step 2 consisted of an inverse L-shaped incision to double the length of the pedicle. The pedicle dimensions were measured and the distance reached when extended toward the hind limb, forelimb, and the muzzle recorded after each stage of the procedure. The vascular patency of the pedicle was determined by intravenous injection of fluorescein dye after the second stage of omental extension. Mean pedicle lengths were 44.5 cm with the first stage of extension and 82.0 cm after full extension. The mean width at the caudal extent of the pedicles after dorsal and full extension was 30.4 cm and 17.2 cm, respectively. Eight of the 10 pedicles were patent after full extension. The fully extended omental pedicles reached and, in most cases, extended beyond the distal extremities and the muzzle. The findings in this study suggest that the canine omentum can be extended to any part of the body without being detached from its vascular supply.

  19. Endoscopic combined “transseptal/transnasal” approach for pituitary adenoma: reconstruction of skull base using pedicled nasoseptal flap in 91 consecutive cases

    Directory of Open Access Journals (Sweden)

    Yasunori Fujimoto

    2015-07-01

    Full Text Available Objective The purpose of this study was to describe the endoscopic combined “transseptal/transnasal” approach with a pedicled nasoseptal flap for pituitary adenoma and skull base reconstruction, especially with respect to cerebrospinal fluid (CSF fistula.Method Ninety-one consecutive patients with pituitary adenomas were retrospectively reviewed. All patients underwent the endoscopic combined “transseptal/transnasal” approach by the single team including the otorhinolaryngologists and neurosurgeons. Postoperative complications related to the flap were analyzed.Results Intra- and postoperative CSF fistulae were observed in 36 (40% and 4 (4.4% patients, respectively. Among the 4 patients, lumbar drainage and bed rest healed the CSF fistula in 3 patients and reoperation for revision was necessary in one patient. Other flap-related complications included nasal bleeding in 3 patients (3.3%.Conclusion The endoscopic combined “transseptal/transnasal” approach is most suitable for a two-surgeon technique and a pedicled nasoseptal flap is a reliable technique for preventing postoperative CSF fistula in pituitary surgery.

  20. [Three-dimensional computed tomography analysis and clinical application of sacroiliac screw placement].

    Science.gov (United States)

    Yin, Y C; Zhang, R P; Li, S L; Hou, Z Y; Chen, W; Zhang, Y Z

    2018-03-01

    of the oblique S(1) sacroiliac screw was (35.6±6.2)°, the anteversion angle was (37.2±4.4)°, and the mean screw length was (90.2±4.7)mm. In the dysmorphic group, the placement rate of S(3) transverse sacroiliac screw was 48.0%, and that of the normal sacral group was 9.1%. Conclusions: There is often dysmorphic in the sacrum in patients with large S(1) anterior vertebral height and S(1)S(2) angle. Sacral dysmorphic patients with posterior pelvic ring injury may be treated with S(1) pedicle oblique sacroiliac screws. S(3) transverse sacroiliac screws should be carefully placed, especially for the absence of sacral dysmorphic in patients.

  1. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    Science.gov (United States)

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p torque than the outboard distal screw (p torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  2. Postoperative dysesthesia in lumbar three-column resection osteotomies.

    Science.gov (United States)

    Zhang, Zhengfeng; Wang, Honggang; Zheng, Wenjie

    2016-08-01

    Three-column lumbar spinal resection osteotomies including pedicle subtraction osteotomy (PSO), vertebral column resection (VCR), and total en bloc spondylectomy (TES) can potentially lead to dorsal root ganglion (DRG) injury which may cause postoperative dysesthesia (POD). The purpose of retrospective study was to describe the uncommon complication of POD in lumbar spinal resection osteotomies. Between January 2009 and December 2013, 64 patients were treated with lumbar three-column spinal resection osteotomies (PSO, n = 31; VCR, n = 29; TES, n = 4) in investigator group. POD was defined as dysesthetic pain or burning dysesthesia at a proper DRG innervated region, whether spontaneous or evoked. Non-steroidal antiinflammatory drugs, central none-opioid analgesic agent, neuropathic pain drugs and/or intervertebral foramen block were selectively used to treat POD. There were 5 cases of POD (5/64, 7.8 %), which consisted of 1 patient in PSO (1/31, 3.2 %), 3 patients in PVCR (3/29, 10.3 %), and 1 patient in TES (1/4, 25 %). After the treatment by drugs administration plus DRG block, all patients presented pain relief with duration from 8 to 38 days. A gradual pain moving to distal end of a proper DRG innervated region was found as the beginning of end. Although POD is a unique and rare complication and maybe misdiagnosed as nerve root injury in lumbar spinal resection osteotomies, combination drug therapy and DRG block have an effective result of pain relief. The appearance of a gradual pain moving to distal end of a proper DRG innervated region during recovering may be used as a sign for the good prognosis.

  3. Parafusos pediculares: estruturas anatômicas em risco no tratamento da escoliose idiopática Tornillos pediculares: las estructuras anatómicas en riesgo en el tratamiento de escoliosis idiopática Pedicle screws: anatomic structures at risk in idiopathic scoliosis treatment

    Directory of Open Access Journals (Sweden)

    Herton Rodrigo Tavares Costa

    2012-12-01

    Full Text Available OBJETIVO: Avaliar a posição das estruturas anatômicas em risco durante a inserção de parafusos pediculares na coluna torácica e sua relação com a variação do ângulo de Cobb. MÉTODOS: Os parâmetros estudados foram: a medida do ângulo de Cobb nas radiografias e a posição da medula espinhal, da cavidade pleural e aorta na ressonância nuclear magnética em relação a uma linha de 40mm criada para simular o parafuso pedicular nas cinco vértebras apicais. RESULTADOS: A distância da aorta ao corpo vertebral e o ângulo de segurança do lado convexo apresentaram diferença estatística quando relacionados com a variação do ângulo de Cobb medido. CONCLUSÃO: Os resultados apresentados sugerem maior risco de lesão da artéria aorta com o aumento do ângulo de Cobb e aumento do risco na inserção de parafusos pediculares no lado convexo da curvatura, quando se considera o ângulo de segurança.OBJETIVO: Evaluar la posición de las estructuras anatómicas en situación de riesgo durante la inserción de tornillos pediculares en la columna torácica y su relación con la variación del ángulo de Cobb. MÉTODOS: Los parámetros estudiados fueron: la medida del ángulo de Cobb en las radiografías y la posición de la médula espinal, la cavidad pleural y la aorta en la RM en relación con una línea de 40mm, diseñada para simular el tornillo pedicular en el plano de las cinco vértebras apicales. RESULTADOS: La distancia desde la aorta hacia el cuerpo vertebral y el ángulo de seguridad en el lado convexo mostraron diferencia estadística relacionada con la variación del ángulo de Cobb medido. CONCLUSIÓN: Los resultados sugieren un mayor riesgo de daño a la aorta con el aumento del ángulo de Cobb e incremento del riesgo en la inserción de tornillos pediculares en el lado convexo cuando se considera el ángulo de seguridad.OBJECTIVE: To evaluate the position of anatomical structures at risk during insertion of pedicle screws in

  4. Investigation of biomechanical behavior of lumbar vertebral segments with dynamic stabilization device using finite element approach

    Science.gov (United States)

    Deoghare, Ashish B.; Kashyap, Siddharth; Padole, Pramod M.

    2013-03-01

    Degenerative disc disease is a major source of lower back pain and significantly alters the biomechanics of the lumbar spine. Dynamic stabilization device is a remedial technique which uses flexible materials to stabilize the affected lumbar region while preserving the natural anatomy of the spine. The main objective of this research work is to investigate the stiffness variation of dynamic stabilization device under various loading conditions under compression, axial rotation and flexion. Three dimensional model of the two segment lumbar spine is developed using computed tomography (CT) scan images. The lumbar structure developed is analyzed in ANSYS workbench. Two types of dynamic stabilization are considered: one with stabilizing device as pedicle instrumentation and second with stabilization device inserted around the inter-vertebral disc. Analysis suggests that proper positioning of the dynamic stabilization device is of paramount significance prior to the surgery. Inserting the device in the posterior region indicates the adverse effects as it shows increase in the deformation of the inter-vertebral disc. Analysis executed by positioning stabilizing device around the inter-vertebral disc yields better result for various stiffness values under compression and other loadings. [Figure not available: see fulltext.

  5. Ball Screw Actuator Including a Compliant Ball Screw Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  6. Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study.

    Science.gov (United States)

    Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami

    2016-11-01

    A cadaveric laboratory study. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. N/A.

  7. [Exploratory study of 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation].

    Science.gov (United States)

    Yin, Yiheng; Yu, Xinguang; Tong, Huaiyu; Xu, Tao; Wang, Peng; Qiao, Guangyu

    2015-10-06

    To investigate the clinical application value of the 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation. From January 2013 to September 2013, 10 patients with basilar invagination and atlantoaxial dislocation needing posterior fixation undertook 3D printing modes at the Department of Neurosurgery in PLA General Hospital. The 1:1 size models were established from skull base to C4 level with different colors between bone structures and vertebral arteries. The simulation of screw insertion was made to investigate the fixation plan and ideal entry point to avoid vertebral artery injury. After obtaining the individual screw insertion data in 3D printing modes, the according surgical operations were performed. The actual clinical results and virtual screw data in 3D printing mode were compared with each other. The 3D printing modes revealed that all the 10 patients had the dysplasia or occipitalized C1 posterior arch indicating C1 posterior arch screw implantation was not suitable. C1 lateral masses were chosen as the screws entry points. C2 screws were designed individually based on the 3D printing modes as follows: 3 patients with aberrant vertebral artery or narrow C2 pedicle less than 3.5 mm were not suitable for pedicle screw implantation. Among the 3 patients, 1 was fixed with C2 laminar screw, and 1 with C2-3 transarticular screw and 1 with C3 pedicle screw (also combined with congenital C2-3 vertebral fusion). Two patients with narrow C2 pedicle between 3.5 and 4mm were designed to choose pedicle screw fixation after 3D printing mode evaluation. One patient with C1 lateral mass vertically dislocated axis was planned with C1-2 transarticular screw fixation. All the other patients were planned with C2 pedicle screws. All the 10 patients had operation designed as the 3D printing modes schemes. The follow-up ranged from 12 to 18 months and all the patients recovered from the clinical symptoms and the bony fusion attained to

  8. [Features of the new minimally invasive techniques facet fixation system «Facet Wedge» in the treatment of degenerative diseases of the lumbar spine in elderly patients.

    Science.gov (United States)

    Byvaltsev, V A; Kalinin, A A; Okoneshnikova, A K

    2017-01-01

    The aim of the study was a comparative analysis of the clinical and radiographic effectiveness of the use of interbody fusion and open pedicle screw stabilization of simultaneous and new minimally invasive techniques facet fixation system «Facet Wedge» in the treatment of degenerative diseases of the lumbar spine in elderly patients. The study included 39 elderly patients (older than 60), which carries out the transforaminal interbody fusion Cage «T-pal»: open transpedicaular stabilization was used in 1st group (n=23), ipsilateral open transpedicular stabilization with contralateral transfaset installing titanium Cage «facet Wedge» -in 2nd group (n=16). We used intraoperative interventions and specific post-operative patient management, clinical data and radiographic outcomes for a comparative analysis of the parameters. Dynamic assessment was made in a period of 8 to 36 months after surgery (median 24 mo.). As a result, it found that the use of the system «facet Wedge» allows you to achieve the best clinical outcomes and fewer postoperative complications compared with open transpedicular stabilization in similar radiographic findings of bone block formation. Low traumatic facet fixation makes it possible to use methods for the treatment of elderly patients with degenerative diseases of the lumbosacral spine.

  9. [Renal angiomyolipoma rupture as a cause of lumbar pain: report of one case].

    Science.gov (United States)

    Cifuentes, Melissa; Calleja, Félix; Hola, José; Daviú, Antonio; Jara, Danilo; Vallejos, Humberto

    2008-08-01

    Renal angiomyolipoma is a benign tumor formed by smooth muscle, adipose tissue and blood vessels. It is commonly found incidentally and its clinical manifestations are pain and abdominal mass or spontaneous tumor rupture with retroperitoneal bleeding. The clinical presentation of a hemorrhagic shock secondary to a retroperitoneal hematoma is uncommon. We report a 40 year-old male who presented to the emergency room with lumbar pain and deterioration of hemodynamic parameters. The CT scan showed a left renal injury associated to an expansive retroperitoneal process. The abdominal exploration, vascular control of the renal pedicle and nephrectomy allowed a successful outcome.

  10. Prediction of Curve Correction Using Alternate Level Pedicle Screw Placement in Patients With Adolescent Idiopathic Scoliosis (AIS) Lenke 1 and 2 Using Supine Side Bending (SB) and Fulcrum Bending (FB) Radiograph.

    Science.gov (United States)

    Kwan, Mun Keong; Zeyada, Hassan E; Chan, Chris Yin Wei

    2015-10-15

    Prospective cohort study. To compare side bending (SB) and fulcrum bending (FB) radiographs in patients with adolescent idiopathic scoliosis (AIS) and effect of magnitude and AR curves on curve correctability. The prediction of correction using side bending flexibility (SBF) and fulcrum bending flexibility (FBF) in alternate level pedicle screw (PS) configuration and effect of curve magnitude and AR curves are not well understood. 100 AIS Lenke 1 and 2 were recruited. Curve magnitude was stratified to G1 (41°-60°), G2 (61°-80°), G3 (>80°). The main thoracic (MT) curves were subclassified to AR curves [Miyanji F, Pawelek JB, Van Valin SE, et al. Is the lumbar modifier useful in surgical decision making? Defining two distinct Lenke 1A curve patterns. Spine 2008;33:2545-51]. Preoperatively SBF and FBF were determined whereas postoperative parameters were correction rate (CR), fulcrum bending correction index (FBCI), and side bending correction index (SBCI). Correlation test were carried out between SBF, FBF versus CR for the cohort. There were 38 (G1), 42 (G2), and 20 (G3) patients. 34% were AR curves. SBF for G1, G2, and G3 were 61.3 ± 14.4, 59.2 ± 16.2 and 43.1 ± 13.1% (P = 0.000) whereas FBF for G1, G2, and G3 were 71.1 ± 16.5, 58.3 ± 18.1 and 52.7 ± 17.1% (P = 0.000). The CR was G1 (74.5 ± 11.5%), G2 (69.2 ± 12.7%), and G3 (70.2 ± 8.6%). FBCI was 1.11 ± 0.3 (G1), 1.28 ± 0.4 (G2) and 1.48 ± 0.6 for G3. SBCI was 1.26 ± 0.2 (G1), 1.50 ± 0.5 (G2), and 1.72 ± 0.4 for G3. There was strong correlation for SBF and FBF versus CR for G1 and G2. For G3, a very strong correlation was established between SBF (r = 0.846, r = 0.716) and FBF versus CR (r = 0.700, r = 0.540). AR curves demonstrated higher SBF and FBF. CR remains almost constant in G1, G2, and G3. SBCI and FBCI increase significantly in G1, G2, and G3. Correlation between SBF and FBF and CR was strong for G1, G2, and very strong for G3. AR curves showed better correctability with SB and FB films.

  11. Transpedicular fixation for the espondilolistesis treatment, espondilolisis and channel lumbar narrow of the lumbosacral column

    International Nuclear Information System (INIS)

    Matta Javier Ernesto; Diaz, Cesar Jacobo; Gamba S, Cesar Enrique

    2002-01-01

    A descriptive, prospective study was designs with the objective of analyzing the experience with the technique of transpedicular fixation, for the treatment of degenerative espondilolistesis, espondilolisis and channel lumbar narrow. Eighty patients (42 men and 38 women) they were intervened between February of 1992 and February of 2002; the age average was of 46,3 years and the minimum pursuit of 7 months. The cases were tabulated according to the diagnostic, clinical presentation, previous interventions, descompressive procedures associated to the fixation, anatomical level of lesion, number of fixed vertebras, number of placed screws, type of bony implants and complications. In 33 patients (41,3%) it diagnose degenerative espondilolistesis, espondilolisis in 24 (30%), channel lumbar narrow in 20 (25%), displasic espondilolistesis in 2,5% and espondiloptosis in 1%. the clinical presentations more frequent were radicular and lumbar pain, with 33,8 each one; one carries out arthrodesis 15-S1 in 38 patients (47,5%) and 14 15 in 15 patients (18,7%). as complications we find deep infection in 7,5% of the cases, neurological deficit in 5%, rupture of duramadre 3,8%, false route of screws, bony failure and material rupture in 2,5% each one and seroma in 1,3%. Doesn't present seudoarthrosis. The transpedicular fixation is a sure technique for the treatment of the degenerative espondilolistesis, espondilolisis and channel lumbar narrow. With the transpedicular fixation the average of fixed vertebras is smaller than with the Harrington and Luque techniques, preserving in more degree the mobility to articulate. The association of the transpedicular fixation with arthrodesis and coalition by means of placement of autogenous implants diminishes the seudoarthrosis incidence

  12. Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging

    Science.gov (United States)

    Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami

    2016-01-01

    Study Design. A cadaveric laboratory study. Objective. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Summary of Background Data. Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. Methods. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. Results. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. Conclusion. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. Level of Evidence: N/A PMID:27513166

  13. Current strategies for the restoration of adequate lordosis during lumbar fusion

    Science.gov (United States)

    Barrey, Cédric; Darnis, Alice

    2015-01-01

    Not restoring the adequate lumbar lordosis during lumbar fusion surgery may result in mechanical low back pain, sagittal unbalance and adjacent segment degeneration. The objective of this work is to describe the current strategies and concepts for restoration of adequate lordosis during fusion surgery. Theoretical lordosis can be evaluated from the measurement of the pelvic incidence and from the analysis of spatial organization of the lumbar spine with 2/3 of the lordosis given by the L4-S1 segment and 85% by the L3-S1 segment. Technical aspects involve patient positioning on the operating table, release maneuvers, type of instrumentation used (rod, screw-rod connection, interbody cages), surgical sequence and the overall surgical strategy. Spinal osteotomies may be required in case of fixed kyphotic spine. AP combined surgery is particularly efficient in restoring lordosis at L5-S1 level and should be recommended. Finally, not one but several strategies may be used to achieve the need for restoration of adequate lordosis during fusion surgery. PMID:25621216

  14. Spondylolysis outcomes in adolescents after direct screw repair of the pars interarticularis.

    Science.gov (United States)

    Snyder, Laura A; Shufflebarger, Harry; O'Brien, Michael F; Thind, Harjot; Theodore, Nicholas; Kakarla, Udaya K

    2014-09-01

    Isthmic spondylolysis can significantly decrease functional abilities, especially in adolescent athletes. Although treatment can range from observation to surgery, direct screw placement through the fractured pars, or Buck's procedure, may be a more minimally invasive procedure than the more common pedicle screw-hook construct. Review of surgical databases identified 16 consecutive patients treated with Buck's procedure from 2004 to 2010. Twelve patients were treated at Miami Children's Hospital and 4 at Barrow Neurological Institute. Demographics and clinical and radiographic outcomes were recorded and analyzed retrospectively. The 16 patients had a median age of 16 years, and 14 were 20 years or younger at the time of treatment. Symptoms included axial back pain in 100% of patients with concomitant radiculopathy in 38%. Pars defects were bilateral in 81% and unilateral in 19% for a total of 29 pars defects treated using Buck's procedure. Autograft or allograft augmented with recombinant human bone morphogenetic protein as well as postoperative bracing was used in all cases. Postoperatively, symptoms resolved completely or partially in 15 patients (94%). Of 29 pars defects, healing was observed in 26 (89.6%) prior to 1 revision surgery, and an overall fusion rate of 97% was observed at last radiological follow-up. There were no implant failures. All 8 athletes in this group had returned to play at last follow-up. Direct screw repair of the pars interarticularis defect as described in this series may provide a more minimally invasive treatment of adolescent patients with satisfactory clinical and radiological outcomes, including return to play of adolescent athletes.

  15. [MINIMALLY INVASIVE SURGERY FOR DIRECT REPAIR OF LUMBAR SPONDYLOLYSIS BY UTILIZING INTRAOPERATIVE NAVIGATION AND MICROENDOSCOPIC TECHNIQUES].

    Science.gov (United States)

    Zhu, Xiaolong; Wang, Jian; Zhou, Yue; Zhang, Zhengfeng; Li, Changqing; Zheng, Wenjie

    2015-10-01

    To analyze the effectiveness of direct screw repair for lumbar spondylolysis by using intraoperative O-arm based navigation and microendoscopic techniques. Between February 2012 and May 2014, 11 consecutive patients with lumbar spondylolysis were treated with Buck's procedure by the aid of intraoperative O-arm based navigation and minimally invasive approach. The debridement and autograft of pars interarticularis defects was performed under microendoscopy. There were 7 males and 4 females, with an average age of 28.4 years (range, 19 - 47 years) and an average disease duration of 10.5 months (range, 8-23 months); no nerve symptoms or signs of lower limb was observed. The radiological examinations showed single level bilateral lumbar spondylolysis without obvious disc degeneration, lumbar instability, or spondylolisthesis. Isthmic injury located at L4 in 2 cases and at L5 in 9 cases. Of 11 patients, 7 were rated as grade 2 disc degeneration, and 4 as grade 3 disc degeneration according to the modified Pfirrmann classification system. The operation time, intraoperative blood loss, and complications were recorded. The fluoroscopic examinations were performed to assess defect repair and screw position. Visual analogue scale (VAS) score was used to evaluate the improvement of low back pain. The average operation time was 147.6 minutes (range, 126-183 minutes). The average blood loss was 54.9 mL (range, 40-85 mL). Primary healing of incision was obtained. There was no complication of nerve root injury, dural tear, or infection. Three patients had pain at donor site postoperatively, and pain disappeared within 3 weeks. The average follow-up duration was 15.7 months (range, 10-23 months). VAS score of low back pain was significantly decreased from preoperative 7.1 ± 2.3 to 1.8 ± 0.4 at last follow-up (t = 13.42, P = 0.01). Of 22 isthmic bone grafting, bilateral isthmic bony fusion was achieved in 7 patients and unilateral isthmic bony fusion in 3 patients at 6-10 months

  16. Will immediate postoperative imbalance improve in patients with thoracolumbar/lumbar degenerative kyphoscoliosis? A comparison between Smith-Petersen osteotomy and pedicle subtraction osteotomy with an average 4 years of follow-up.

    Science.gov (United States)

    Bao, Hongda; He, Shouyu; Liu, Zhen; Zhu, Zezhang; Qiu, Yong; Zhu, Feng

    2015-03-01

    A retrospective radiographical study. To compare compensatory behavior of coronal and sagittal alignment after pedicle subtraction osteotomy (PSO) and Smith-Petersen osteotomy (SPO) for degenerative kyphoscoliosis. There was a paucity of literature paying attention to the postoperative imbalance after PSO or SPO and natural evolution of the imbalance. A retrospective study was performed on 68 consecutive patients with degenerative kyphoscoliosis treated by lumbar PSO (25 patients) or SPO (43 patients) procedures at a single institution. Long-cassette standing radiographs were taken preoperatively, postoperatively, and at the last follow-up and radiographical parameters were measured. The lower instrumented vertebral level and level of osteotomy were compared between the patients with and without improvement. Negative sagittal vertical axis (SVA) was observed in the PSO group postoperatively, implying an overcorrection of SVA. This negative SVA improved spontaneously during follow-up (P imbalance (P = 0.027), whereas no difference in term of levels of osteotomy was found (P > 0.05). The overcorrection of SVA is more often seen in the PSO group. The coronal imbalance is more likely to occur in the SPO group. The postoperative sagittal imbalance often spontaneously improves with time. Lower instrumented vertebra at S1 or with pelvic fixation should be regarded as potential risk factors for persistent coronal imbalance in patients with SPO. 3.

  17. Outcome of instrumented spinal fusion for chronic low back pain: review of 100 patients

    International Nuclear Information System (INIS)

    Qureshi, M.A; Pasha, I.F.; Malik, A.S.; Asad, A.; Aebi, M.

    2010-01-01

    Objective of this study was to evaluate the outcome of instrumented spinal fusion in selected patients with Chronic Low Back Pain (CLBP) in our setup. Consecutive first one hundred patients were selected from spine unit database that underwent instrumented spinal fusion for chronic low back pain lasting more than one year, due to degenerative disease of spine. Average age was 42 years. There were 62 males and 38 females. Diagnosis included; spinal stenosis (26%), failed disc surgery (22%), spondylolisthesis (19%), degenerative disc disease (17%), and instability (16%). Operations performed; Pedicle Screw Fixation (PSF) with Postero-lateral Fusion (PLF) in 3% patients. Trans Laminar Facet Screw (TLFS) with PLF in 24% patients. Anterior Lumbar Inter-body Fusion (ALIF) in 9% patients. Posterior Lumbar Inter-body Fusion (PLIF) in 40% patients and Trans-foraminal Lumbar Inter-body Fusion (TLIF) in 24% patients. Average follow up was for 30 months. 86% patients had full spinal fusion. 71% patients were fully satisfied with treatment, 28% were partially satisfied. Post-operatively, on average, visual analogue scale (VAS) showed 48 points significant improvement and Oswestry Disability Index (ODI) showed 53 points significant improvement. Instrumented Spinal Fusion is effective in our set up for relieving symptoms and improving functional outcome in selected patients with debilitating Chronic Low Back Pain due to degenerative disease of spine. Single fusion technique is not ideal for all types of patients and surgeon has to be versatile and trained in using different fusion techniques as the situation demands. (author)

  18. Finite element simulation and clinical follow-up of lumbar spine biomechanics with dynamic fixations.

    Directory of Open Access Journals (Sweden)

    Yolanda Más

    Full Text Available Arthrodesis is a recommended treatment in advanced stages of degenerative disc disease. Despite dynamic fixations were designed to prevent abnormal motions with better physiological load transmission, improving lumbar pain and reducing stress on adjacent segments, contradictory results have been obtained. This study was designed to compare differences in the biomechanical behaviour between the healthy lumbar spine and the spine with DYNESYS and DIAM fixation, respectively, at L4-L5 level. Behaviour under flexion, extension, lateral bending and axial rotation are compared using healthy lumbar spine as reference. Three 3D finite element models of lumbar spine (healthy, DYNESYS and DIAM implemented, respectively were developed, together a clinical follow-up of 58 patients operated on for degenerative disc disease. DYNESYS produced higher variations of motion with a maximum value for lateral bending, decreasing intradiscal pressure and facet joint forces at instrumented level, whereas screw insertion zones concentrated stress. DIAM increased movement during flexion, decreased it in another three movements, and produced stress concentration at the apophyses at instrumented level. Dynamic systems, used as single systems without vertebral fusion, could be a good alternative to degenerative disc disease for grade II and grade III of Pfirrmann.

  19. Solitary myofibroma of the lumbar vertebra: adult case

    International Nuclear Information System (INIS)

    Konishi, E.; Yanagisawa, A.; Mazaki, T.; Urata, Y.; Tanaka, K.; Kanoe, H.; Ikenaga, M.; Hayakawa, K.

    2007-01-01

    We present the first known adult case of solitary myofibroma of bone, which affected a lumbar vertebra in a 33-year-old male. Radiography identified a purely lytic lesion with a sclerotic rim in the right pedicle of L1. CT showed an expansile lytic lesion with a sclerotic rim. MRI of the lesion revealed an isointense signal on T1-weighted images, an inhomogeneously hyperintense signal on T2-weighted images, and marked enhancement with gadolinium. Pathological study showed a mixed picture of nodular proliferation of spindle-shaped myoid cells and hemangiopericytomatous proliferation of short spindle/small round cells. The tumor cells were immunoreactive for smooth muscle actin and immunonegative for desmin. This case of solitary myofibroma of bone is exceptionally rare because of its occurrence in an adult older than 20 years of age and its location at an extra-craniofacial site. (orig.)

  20. Solitary myofibroma of the lumbar vertebra: adult case

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, E.; Yanagisawa, A. [Kyoto Prefectural University of Medicne, Department of Pathology, Kyoto (Japan); Mazaki, T.; Urata, Y. [Kyoto City Hospital, Department of Pathology, Kyoto (Japan); Tanaka, K.; Kanoe, H.; Ikenaga, M. [Kyoto City Hospital, Department of Orthopedic Surgery, Kyoto (Japan); Hayakawa, K. [Kyoto City Hospital, Department of Radiology, Kyoto (Japan)

    2007-06-15

    We present the first known adult case of solitary myofibroma of bone, which affected a lumbar vertebra in a 33-year-old male. Radiography identified a purely lytic lesion with a sclerotic rim in the right pedicle of L1. CT showed an expansile lytic lesion with a sclerotic rim. MRI of the lesion revealed an isointense signal on T1-weighted images, an inhomogeneously hyperintense signal on T2-weighted images, and marked enhancement with gadolinium. Pathological study showed a mixed picture of nodular proliferation of spindle-shaped myoid cells and hemangiopericytomatous proliferation of short spindle/small round cells. The tumor cells were immunoreactive for smooth muscle actin and immunonegative for desmin. This case of solitary myofibroma of bone is exceptionally rare because of its occurrence in an adult older than 20 years of age and its location at an extra-craniofacial site. (orig.)

  1. Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws.

    Science.gov (United States)

    Zipprich, Holger; Rathe, Florian; Pinz, Sören; Schlotmann, Luca; Lauer, Hans-Christoph; Ratka, Christoph

    The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.

  2. Cervical Fusion for Absent Pedicle Syndrome Manifesting with Myelopathy.

    Science.gov (United States)

    Goodwin, C Rory; Desai, Atman; Khattab, Mohamed H; Elder, Benjamin D; Bydon, Ali; Wolinsky, Jean-Paul

    2016-02-01

    Absent congenital pedicle syndrome is a posterior arch defect characterized by numerous congenital and mechanical abnormalities that result from disconnection of the anterior and posterior columns of the spinal canal. Absent congenital pedicle syndrome is a rare anomaly that is most commonly diagnosed incidentally, after evaluation of minor trauma, or after complaints of chronic neck pain. We report a case of absent congenital pedicle syndrome in a patient who presented with myelopathy and lower extremity weakness and review the literature on the surgical management of this entity. A 32-year-old woman with a history of systemic lupus erythematosus presented to the Neurosurgery Service with progressive weakness in her upper and lower extremities, clonus, and hyperreflexia. Magnetic resonance imaging revealed congenital absence of the pedicles of C2, C3, C4, C5, and C6 with a congenitally narrow canal at C4-5. The patient underwent a staged anterior and posterior cervical decompression and fusion. She was placed in a halo after surgery; at the 1-year follow-up, she was ambulatory with demonstrated improvement in weakness and fusion of her cervical spine. Absent congenital pedicle syndrome is rare, and most reported cases were treated conservatively. Surgical management is reserved for patients with myelopathy or instability. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Single-stage epidural catheter lavage with posterior spondylodesis in lumbar pyogenic spondylodiscitis with multilevel epidural abscess formation.

    Science.gov (United States)

    Tschoeke, Sven K; Kayser, Ralph; Gulow, Jens; Hoeh, Nicolas von der; Salis-Soglio, Georg von; Heyde, Christoph

    2014-11-01

    Despite significant advances in the conservative management of pyogenic spondylodiscitis, consecutive instability, deformity, and/or neurologic compromise demands a prompt surgical intervention. However, in rare cases involving additional multilevel epidural abscess formation, the appropriate surgical strategy remains controversial. In this retrospective cohort analyses, we evaluated the efficacy of a single-stage posterior approach with the addition of a one-time multilevel epidural lavage via the surgically exposed interlaminar fenestration of the infected segment. From January 2009 through December 2010, 73 patients presenting pyogenic spondylodiscitis with instability of the lumbar spine were admitted. In all cases, the surgical strategy included a radical resection of the affected intervertebral disc and stabilization by intervertebral fusion using a titanium cage with autologous bone grafting in a level-dependent posterior approach with additional pedicle screw-and-rod instrumentation. In cases where multilevel abscess formation was evident, the standard surgical procedure was complemented by drainage and irrigation of the abscess from posterior by carefully advancing a soft infant feeding tube via the surgically exposed epidural space under fluoroscopic guidance. All patients received complementary oral antibiotic therapy for 12 weeks and were followed-up for a minimum of 12 months postoperatively. Ten patients (three male and seven female patients; mean age: 64.9 ± 10.9 years) presented with an additional lumbar epidural abscess extending beyond three levels proximal or distal to the infected disc. In all 10 patients the laboratory-chemical inflammatory parameters (leukocyte count, C-reactive protein) remained within the physiologic range after completing antibiotic therapy throughout the 1-year follow-up period. The plain radiographs and magnetic resonance imaging demonstrated solid fusion and the complete remission of the initial abscess formation after

  4. Segmental fracture of the lumbar spine.

    Science.gov (United States)

    O'hEireamhoin, Sven; Devitt, Brian; Baker, Joseph; Kiely, Paul; Synnott, Keith

    2010-10-01

    A case report is presented. To describe a rare, previously undescribed pattern of spinal injury. This seems to be a unique injury with no previously described injuries matching the fracture pattern observed. This is a case report based on the experience of the authors. The discussion includes a short literature review based on pubmed searches. We report the case of a 26-year-old female cyclist involved in a road traffic accident with a truck resulting in complete disruption of the lumbar spine. The cyclist was caught on the inside of a truck turning left and seems to have passed under the rear wheels. She was brought to the local emergency department where, after appropriate resuscitation, trauma survey revealed spinal deformity with complete neurologic deficit below T12 and fractured pubic rami, soft tissue injuries to the perineum and multiple abrasions. Plain radiology showed a segmental fracture dislocation of her lumbar vertebrae, extending from the L1 superior endplate through to L4-L5 disc space. The entire segment was displaced in both anteroposterior and lateral planes. Computed tomography confirmed these injuries and ruled out significant visceral injury. She was transferred to the national spinal unit (author unit), where she underwent reduction and fixation with rods and screws from T9-S1, using one cross-link. After her immediate postoperative recovery, she was referred to the national rehabilitation unit. Although so-called "en bloc" lumbar fractures have been previously described, the authors were unable to find any injury of this degree in the literature. This rare injury seems to show a pattern of spinal injury previously undescribed.

  5. Segmental correction of adolescent idiopathic scoliosis by all-screw fixation method in adolescents and young adults. minimum 5 years follow-up with SF-36 questionnaire

    Directory of Open Access Journals (Sweden)

    Yu Ching-Hsiao

    2012-02-01

    Full Text Available Abstract Background In our institution, the fixation technique in treating idiopathic scoliosis was shifted from hybrid fixation to the all-screw method beginning in 2000. We conducted this study to assess the intermediate -term outcome of all-screw method in treating adolescent idiopathic scoliosis (AIS. Methods Forty-nine consecutive patients were retrospectively included with minimum of 5-year follow-up (mean, 6.1; range, 5.1-7.3 years. The average age of surgery was 18.5 ± 5.0 years. We assessed radiographic measurements at preoperative (Preop, postoperative (PO and final follow-up (FFU period. Curve correction rate, correction loss rate, complications, accuracy of pedicle screws and SF-36 scores were analyzed. Results The average major curve was corrected from 58.0 ± 13.0° Preop to 16.0 ± 9.0° PO(p p = 0.12 FFU. This revealed a 72.7% correction rate and a correction loss of 2.4° (3.92%. The thoracic kyphosis decreased little at FFU (22 ± 12° to 20 ± 6°, (p = 0.25. Apical vertebral rotation decreased from 2.1 ± 0.8 PreOP to 0.8 ± 0.8 at FFU (Nash-Moe grading, p Conclusion Follow-up more than 5 years, the authors suggest that all-screw method is an efficient and safe method.

  6. Complications in lumbar spine surgery: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Luca Proietti

    2013-01-01

    Full Text Available Background: Surgical treatment of adult lumbar spinal disorders is associated with a substantial risk of intraoperative and perioperative complications. There is no clearly defined medical literature on complication in lumbar spine surgery. Purpose of the study is to retrospectively evaluate intraoperative and perioperative complications who underwent various lumbar surgical procedures and to study the possible predisposing role of advanced age in increasing this rate. Materials and Methods: From 2007 to 2011 the number and type of complications were recorded and both univariate, (considering the patients′ age and a multivariate statistical analysis was conducted in order to establish a possible predisposing role. 133 were lumbar disc hernia treated with microdiscetomy, 88 were lumbar stenosis, treated in 36 cases with only decompression, 52 with decompression and instrumentation with a maximum of 2 levels. 26 patients showed a lumbar fracture treated with percutaneous or open screw fixation. 12 showed a scoliotic or kyphotic deformity treated with decompression, fusion and osteotomies with a maximum of 7.3 levels of fusion (range 5-14. 70 were spondylolisthesis treated with 1 or more level of fusion. In 34 cases a fusion till S1 was performed. Results: Of the 338 patients who underwent surgery, 55 showed one or more complications. Type of surgical treatment ( P = 0.004, open surgical approach (open P = 0.001 and operative time ( P = 0.001 increased the relative risk (RR of complication occurrence of 2.3, 3.8 and 5.1 respectively. Major complications are more often seen in complex surgical treatment for severe deformities, in revision surgery and in anterior approaches with an occurrence of 58.3%. Age greater than 65 years, despite an increased RR of perioperative complications (1.5, does not represent a predisposing risk factor to complications ( P = 0.006. Conclusion: Surgical decision-making and exclusion of patients is not justified only

  7. Positioning device for screwing or unscrewing screw nut

    International Nuclear Information System (INIS)

    Sevelinge, G.

    1987-01-01

    This automatic positioning device for screwing or unscrewing a screw nut on a closure stud has a drawed socket and means for axially centre and angularly by wedge the socket on the closure stud and generate a continuous spiral between the socket and the closure stud [fr

  8. Evaluation of efficacy of a new hybrid fusion device: a randomized, two-centre controlled trial.

    Science.gov (United States)

    Siewe, Jan; Bredow, Jan; Oppermann, Johannes; Koy, Timmo; Delank, Stefan; Knoell, Peter; Eysel, Peer; Sobottke, Rolf; Zarghooni, Kourosh; Röllinghoff, Marc

    2014-09-05

    The 360° fusion of lumbar segments is a common and well-researched therapy to treat various diseases of the spine. But it changes the biomechanics of the spine and may cause adjacent segment disease (ASD). Among the many techniques developed to avoid this complication, one appears promising. It combines a rigid fusion with a flexible pedicle screw system (hybrid instrumentation, "topping off"). However, its clinical significance is still uncertain due to the lack of conclusive data. The study is a randomized, therapy-controlled, two-centre trial conducted in a clinical setting at two university hospitals. If they meet the criteria, outpatients presenting with degenerative disc disease, facet joint arthrosis or spondylolisthesis will be included in the study and randomized into two groups: a control group undergoing conventional fusion surgery (PLIF - posterior lumbar intervertebral fusion), and an intervention group undergoing fusion surgery using a new flexible pedicle screw system (PLIF + "topping off"), which was brought on the market in 2013. Follow-up examination will take place immediately after surgery, after 6 weeks and after 6, 12, 24 and 36 months. An ongoing assessment will be performed every year.Outcome measurements will include quality of life and pain assessments using validated questionnaires (ODI - Ostwestry Disability Index, SF-36™ - Short Form Health Survey 36, COMI - Core Outcome Measure Index). In addition, clinical and radiologic ASD, sagittal balance parameters and duration of work disability will be assessed. Inpatient and 6-month mortality, surgery-related data (e.g., intraoperative complications, blood loss, length of incision, surgical duration), postoperative complications (e.g. implant failure), adverse events, and serious adverse events will be monitored and documented throughout the study. New hybrid "topping off" systems might improve the outcome of lumbar spine fusion. But to date, there is a serious lack of and a great need

  9. Repair of the spondylolysis in lumbar spine

    International Nuclear Information System (INIS)

    Matta Ibarra, Javier; Arrieta Maria, Victor; Torres Romero Fernando; Ramirez Cabrales, Vladimir

    2005-01-01

    The objective is to present the surgical experience in the repair of the spondylolysis in lumbar spine. Background: Spodylolysis is an important cause of low back pain in young adults and is responsible for high grade of incapacity. Classically, patients with surgical indications with Spondylolysis have been treated with vertebral arthrodesis arthrodesis, with the following functional lost of the intervened segment and biomechanical overload of the upper contiguous segment. There are not previous reports about repairing of lysis in national literature and international references in this technique are scarce. Materials and methods: Eight patients within 2002-2004 were operated, a direct repairing of the lyses by in situ, fusion and interfragmental osteosynthesis with AO 3.5 mm titanium cortical screws with autogenous bone grafts was achieved. The casuistic was analyzed depending on clinical presentation, consolidation, mobility and vitality of the disc in imaginology studies. Results: During the follow-up a firm fusion in all cases, mobility and vitality preservation of the L5-S1 intervertebral disc was detected. There was neither infection nor neurological deficit. Recommendations: Repairing of spondylolysis in lumbar column, in young symptomatic patients without or with mild lystesis (grade I) and without associated disc damage, is a safe surgical technique

  10. Delayed vertebral diagnosed L4 pincer vertebral fracture, L2-L3 ruptured vertebral lumbar disc hernia, L5 vertebral wedge fracture - Case report

    Directory of Open Access Journals (Sweden)

    Balasa D

    2016-08-01

    Full Text Available An association between delayed ruptured lumbar disc hernia, L5 vertebral wedge fracture and posttraumaticL4 pincer vertebral fracture (A2.3-AO clasification at different levels is a very rare entity. We present the case of a 55 years old male who falled down from a bicycle. 2 months later because of intense and permanent vertebral lumbar and radicular L2 and L3 pain (Visual Scal Autologus of Pain7-8/10 the patient came to the hospital. He was diagnosed with pincer vertebral L4 fracture (A2.3-AO clasification and L2-L3 right ruptured lumbar disc hernia in lateral reces. The patient was operated (L2-L3 right fenestration, and resection of lumbar disc hernia, bilateral stabilisation, L3-L4-L5 with titan screws and postero-lateral bone graft L4 bilateral harvested from iliac crest.

  11. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    Science.gov (United States)

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  12. [Fracture of implant abutment screws and removal of a remaining screw piece

    NARCIS (Netherlands)

    Broeke, S.M. van den; Baat, C. de

    2008-01-01

    Fracture of the implant abutment screws is a complication which can render an implant useless. The prevalence of abutment screw fracture does not exceed 2.5% after 10 years. Causes are loosening of implant abutment screw, too few, too short or too narrow implants, implants not inserted perpendicular

  13. Correlation analysis between change in thoracic kyphosis and multilevel facetectomy and screw density in main thoracic adolescent idiopathic scoliosis surgery.

    Science.gov (United States)

    Sudo, Hideki; Abe, Yuichiro; Kokabu, Terufumi; Ito, Manabu; Abumi, Kuniyoshi; Ito, Yoichi M; Iwasaki, Norimasa

    2016-09-01

    Controversy exists regarding the effects of multilevel facetectomy and screw density on deformity correction, especially thoracic kyphosis (TK) restoration in adolescent idiopathic scoliosis (AIS) surgery. This study aimed to evaluate the effects of multilevel facetectomy and screw density on sagittal plane correction in patients with main thoracic (MT) AIS curve. A retrospective correlation and comparative analysis of prospectively collected, consecutive, non-randomized series of patients at a single institution was undertaken. Sixty-four consecutive patients with Lenke type 1 AIS treated with posterior correction and fusion surgery using simultaneous double-rod rotation technique were included. Patient demographics and preoperative and 2-year postoperative radiographic measurements were the outcome measures for this study. Multiple stepwise linear regression analysis was conducted between change in TK (T5-T12) and the following factors: age at surgery, Risser sign, number of facetectomy level, screw density, preoperative main thoracic curve, flexibility in main thoracic curve, coronal correction rate, preoperative TK, and preoperative lumbar lordosis. Patients were classified into two groups: TKcorrect hypokyphosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Effect of Repeated Screw Joint Closing and Opening Cycles and Cyclic Loading on Abutment Screw Removal Torque and Screw Thread Morphology: Scanning Electron Microscopy Evaluation.

    Science.gov (United States)

    Arshad, Mahnaz; Mahgoli, Hosseinali; Payaminia, Leila

    To evaluate the effect of repeated screw joint closing and opening cycles and cyclic loading on abutment screw removal torque and screw thread morphology using scanning electron microscopy (SEM). Three groups (n = 10 in each group) of implant-abutment-abutment screw assemblies were created. There were also 10 extra abutment screws as new screws in group 3. The abutment screws were tightened to 12 Ncm with an electronic torque meter; then they were removed and removal torque values were recorded. This sequence was repeated 5 times for group 1 and 15 times for groups 2 and 3. The same screws in groups 1 and 2 and the new screws in group 3 were then tightened to 12 Ncm; this was also followed by screw tightening to 30 Ncm and retightening to 30 Ncm 15 minutes later. Removal torque measurements were performed after screws were subjected to cyclic loading (0.5 × 10⁶ cycles; 1 Hz; 75 N). Moreover, the surface topography of one screw from each group before and after cyclic loading was evaluated with SEM and compared with an unused screw. All groups exhibited reduced removal torque values in comparison to insertion torque in each cycle. However, there was a steady trend of torque loss in each group. A comparison of the last cycle of the groups before loading showed significantly greater torque loss value in the 15th cycle of groups 2 and 3 compared with the fifth cycle of group 1 (P abutment is definitively placed.

  15. Which is the ideal point of time to perform intraoperative 3D imaging in dorsal stabilisation of thoracolumbar spine fractures? A matched pair analysis.

    Science.gov (United States)

    Beck, M; Mittlmeier, T; Gierer, P; Rotter, R; Harms, C; Gradl, G

    2010-10-01

    After dorsal stabilisation of vertebral fractures by an internal fixateur the postoperative computed tomography is a standard procedure to control the positions of the pedicle screws, the success of the reposition, the clearance of the spinal canal and to plane an additive secondary ventral stabilisation. An intraoperative scan with a 3D image intensifier may clarify these questions directly after the implantation with the possibility of an immediate correction of the implants. The aim of this study was to find out the optimal point of time to perform an intraoperative 3D scan and if a postoperative computed tomography is dispensable. Intraoperative 3D scans were carried out on 33 patients with thoracolumbar spine fractures (T11-L5) after bi-segmental fixateur interne montage (Group 1). A matched pair group of 33 patients (Group 2) with a 3D scan after implantation of pedicle screws was built. A postoperative computed tomography of the instrumented spinal section was done in all patients. The following measurements were done in sagittal and axial reconstruction planes and were compared: classification of screw positions, maximal axial diameter of pedicles, cortical perforation of the screws. Additionally in Group 1 the distance between the upper and lower end plates of the injured section, the height of posterior vertebral body wall, the dislocation of the posterior wall and the minimal diameter of the spinal canal were measured. The intraoperative scoring of pedicle screws positions and the measurement of pedicle width showed in both groups a significant accordance with the computed tomography determinations. The measurements "posterior wall dislocation" and "diameter of spinal canal" were only possible in 24 3D scans and showed a significant difference compared with the CT data. The picture quality in Group 2 was scored significantly better than for Group 1 with the complete assembly of the fixateur. The ideal point of time for an intraoperative 3D imaging with

  16. L5 pedicle length is increased in subjects with spondylolysis: an anatomic study of 1072 cadavers.

    Science.gov (United States)

    Bajwa, Navkirat S; Toy, Jason O; Ahn, Nicholas U

    2012-11-01

    In spondylolisthesis, it is believed that as L5 slips on S1, the pedicle may become elongated in response to the instability in an attempt to bridge the defect. Whether patients with spondylolysis, which is largely developmental, also develop elongation of the pedicles is unknown. The purpose of this study is to evaluate and quantify the increase in L5 pedicle length in subjects with spondylolysis as compared with normal healthy subjects. Nine hundred fifty-two human cadaveric specimens without spondylolysis and 120 specimens with spondylolysis from the Hamann-Todd Osteological Collection were examined by a single examiner. Baseline data, including age, sex, and race of specimens, were collected. Digital calipers were used to measure the pedicle lengths at the L5 level. Linear regression analysis was performed to compare the L5 pedicle lengths in healthy patients and patients with spondylolysis. Linear regression showed a significant association of increased L5 pedicle length in subjects with spondylolysis. The average L5 pedicle length in subjects with spondylolysis was greater compared with subjects without spondylolysis. In spondylolytic specimens, pedicles start to elongate after the age of 40 years. The pedicle lengths increase progressively from 5.6 mm at 40 years to 6.7 mm at 80 years with a 1% to 3% increment every decade. The pedicle lengths showed little variation in specimens from healthy subjects. In spondylolytic specimens, there is progressive elongation of L5 pedicle length after the third decade. An increase in L5 pedicle length in all age groups compared with the specimens from healthy subjects suggests that pathologic changes occur in bony anatomy of L5 vertebrae as early as adolescence when the condition develops.

  17. CT of lumbar spine disk herniation: correlation with surgical findings

    International Nuclear Information System (INIS)

    Firooznia, H.; Benjamin, V.; Kricheff, I.I.; Rafii, M.; Golimbu, C.

    1984-01-01

    Computed tomography (CT) of the lumbar spine was performed with selectively positioned 5-mm-thick axial cross sections to examine each disk level from the top of the neural foramen to the pedicle of the next caudad vertebra. One hundred consecutive patients with 116 surgical disk explorations were reviewed. There was agreement between the CT and surgical findings in 89 patients (104 explorations) in determination of presence or absence of a herniated nucleus pulposus (HNP). Discrepancy occurred in 12 instances (11 patients): two because of incorrect interpretations, five in previously operated patients, three in spondylolisthesis, and two in spinal stenosis. There were 97 true-positives, eight false-negatives, seven true-negatives, and four false-positives. If nine previously operated patients are excluded from the study, then CT was accurate in detection of presence or absence of an HNP in 93% of the disk explorations

  18. [Cement augmentation on the spine : Biomechanical considerations].

    Science.gov (United States)

    Kolb, J P; Weiser, L; Kueny, R A; Huber, G; Rueger, J M; Lehmann, W

    2015-09-01

    Vertebral compression fractures are the most common osteoporotic fractures. Since the introduction of vertebroplasty and screw augmentation, the management of osteoporotic fractures has changed significantly. The biomechanical characteristics of the risk of adjacent fractures and novel treatment modalities for osteoporotic vertebral fractures, including pure cement augmentation by vertebroplasty, and cement augmentation of screws for posterior instrumentation, are explored. Eighteen human osteoporotic lumbar spines (L1-5) adjacent to vertebral bodies after vertebroplasty were tested in a servo-hydraulic machine. As augmentation compounds we used standard cement and a modified low-strength cement. Different anchoring pedicle screws were tested with and without cement augmentation in another cohort of human specimens with a simple pull-out test and a fatigue test that better reflects physiological conditions. Cement augmentation in the osteoporotic spine leads to greater biomechanical stability. However, change in vertebral stiffness resulted in alterations with the risk of adjacent fractures. By using a less firm cement compound, the risk of adjacent fractures is significantly reduced. Both screw augmentation techniques resulted in a significant increase in the withdrawal force compared with the group without cement. Augmentation using perforated screws showed the highest stability in the fatigue test. The augmentation of cement leads to a significant change in the biomechanical properties. Differences in the stability of adjacent vertebral bodies increase the risk of adjacent fractures, which could be mitigated by a modified cement compound with reduced strength. Screws that were specifically designed for cement application displayed greatest stability in the fatigue test.

  19. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Directory of Open Access Journals (Sweden)

    Bo Kyun Sim

    2017-01-01

    Full Text Available The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  20. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Science.gov (United States)

    Kim, Bongju; Shin, Yoo Jin

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA. PMID:29065610

  1. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    Directory of Open Access Journals (Sweden)

    Hughes Matthew

    2018-01-01

    Discussion: For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction.

  2. OUTCOMES OF HILAR PEDICLE CONTROL USING SUTURE LIGATION DURING LAPAROSCOPIC SPLENECTOMY.

    Science.gov (United States)

    Makgoka, M

    2017-06-01

    Laparoscopic splenectomy is a well described gold standard procedure for various indications. One of the key steps during laparoscopic splenectomy is the hilar pedicle vessels control, which can be challenging in most cases. Most centres around the world recommend the use Ligaclib or endovascular staplers as Methods of choice for hilar pedicle control but the issue is the cost and efficiency of the laparoscopic haemostatic devices. A descriptive retrospective study of patients who had laparoscopic splenectomy from 2013 to present. Hilar splenic vessel control was done with suture ligation. We looked at outcomes of patients offered this technique, complications of this technique, and describing the technique of hilar control in laparoscopic splenectomy. Total of 27 patients had laparoscopic splenectomy with splenic hilar pedicle control with suture ligation. Mean operative time, mean blood volume loss, length of hospital stay, postoperative complications conversion to laparotomy. Laparoscopic hilar pedicle control with suture ligation is safe and effective for the patient in our hospital setting.

  3. The influence of muscle forces on the stress distribution in the lumbar spine

    DEFF Research Database (Denmark)

    Wong, C; Rasmussen, J; Simonsen, Erik B.

    2011-01-01

    muscles. Results: In general the von Mises stress was larger by 30 %, and even higher when looking at the von Mises stress distribution in the superio-anterior and central part of the vertebral body and in the pedicles. Conclusion: The application of spine muscles to a finite element model showed markedly...... larger von Mises stress responses in the central and anterior part of the vertebral body, which can be tolerated in the young and healthy spine, but it would increase the risk of compression fractures in the elderly, osteoporotic spine.......Introduction: Previous studies of bone stresses in the human lumbar spine have relied on simplified models when modeling the spinal musculature, even though muscle forces are likely major contributors to the stresses in the vertebral bones. Detailed musculoskeletal spine models have recently become...

  4. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    OpenAIRE

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access ...

  5. Extraction of sunflower oil by twin screw extruder: screw configuration and operating condition effects

    Energy Technology Data Exchange (ETDEWEB)

    Kartika, I.A. [FATETA-IPB, Bogor (Indonesia). Department of Agroindustrial Technology; Pontalier, P.Y.; Rigal, L. [Laboratoire de Chimie Agro-Industrielle, UMR 1010 INRA/INP-ENSIACET, Toulouse (France)

    2006-12-15

    The objective of this study was to investigate the screw configuration allowing oil extraction from sunflower seeds with a twin-screw extruder. Experiments were conducted using a co-rotating twin-screw extruder. Five screw profiles were examined to define the best performance (oil extraction yield, specific mechanical energy and oil quality) by studying the influence of operating conditions, barrel temperature, screw speed and feed rate. Generally, the position and spacing between two reversed screw elements affected oil extraction yield. An increase of oil extraction yield was observed as the reversed screw elements were moved with increased spacing between two elements and with smaller pitch elements. In addition, oil extraction yield increased as barrel temperature, screw speed and feed rate were decreased. Highest oil extraction yield (85%) with best cake meal quality (residual oil content lower than 13%) was obtained under operating conditions of 120 {sup o}C, 75 rpm and 19 kg/h. Furthermore, the operating parameters influenced energy input. A decrease in barrel temperature and feed rate followed by an increase in screw speed increased energy input, particularly specific mechanical energy input. Effect of the operating parameters on oil quality was less important. In all experiments tested, the oil quality was very good. The acid value was below 2 mg of KOH/g of oil and total phosphorus content was low, below 100 mg/kg. (author)

  6. Development of load calculation techniques on screw and screw press energy consumption

    OpenAIRE

    Татарьянц, Максим Сергеевич; Завинский, Сергей Иванович; Трошин, Алексей Георгиевич

    2015-01-01

    The process of pressing of wood chips in screw machines is researched. It is defined processes taking place in different parts of the screw, formulas allowing to calculate the loads acting on the screw flights, as well as to determine the power required for compression. The unit costs of energy consumption and raw materials in the degree of heat pressing are determined

  7. PEDICLE TONGUE FLAP SURGERY IN ORAL SUBMUCOUS FIBROSIS

    Directory of Open Access Journals (Sweden)

    Muthubabu K

    2016-09-01

    Full Text Available BACKGROUND Oral submucous fibrosis is a disease of unknown aetiology and is a legacy of Indians. It has been variously treated both medically and surgically but neither has been found to be rewarding. Various groups have been studying the therapy schedules and aetiological association, but the conclusions have remained unclear. AIM The study aims to focus on newer surgical therapy stressing on the mechanics and use of pedicle tongue flap in the management of this condition. METHODS AND MATERIALS The study comprised of 40 patients from our outpatient department suffering from oral submucous fibrosis in the age group of 11 to 70 years. The contributory factors of oral submucous fibrosis and the symptoms of the disease were evaluated and the role of pedicle tongue flap surgery in the management of this disease which is a premalignant condition is discussed. RESULTS AND CONCLUSION Pedicle tongue flap surgery has given promising results in the treatment of trismus due to oral submucous fibrosis. After the surgery, none of our patients developed any malignant change.

  8. Cross sectional CT morphology of the three lower lumbar vertebrae: with contributions to a more accurate interpretation of AP radiographs of the lumbar spine

    International Nuclear Information System (INIS)

    Schaik, J.P.J. van.

    1984-01-01

    This thesis is concerned with a cross-sectional morphological analysis of certain structures contained in the bony portion of the motion segments between L3 and S1, the vertebral bodies included. Measurements of lengths and angles were based on the use of constant reference points, which permitted comparative studies. Reference points were selected which were sufficiently well defined as to avoid gross errors in measurements. The lateral borders of the vertebral body of L3 are well visualized in AP radiographs, as well as the entire circumference of the pedicles. The bony cortical margins of these structures are more or less orientated in a sagittal direction, and are therefore caught by the X ray beam tangentially over the major part of their length. This tangential projection results in a sharp definition of these margins. Radiographic analysis of wired specimens of lumbar vertebrae showed that the shadow cast by the spinous process in the AP projection corresponds with its posterior portion. (Auth.)

  9. 2D and 3D assessment of sustentaculum tali screw fixation with or without Screw Targeting Clamp.

    Science.gov (United States)

    De Boer, A Siebe; Van Lieshout, Esther M M; Vellekoop, Leonie; Knops, Simon P; Kleinrensink, Gert-Jan; Verhofstad, Michael H J

    2017-12-01

    Precise placement of sustentaculum tali screw(s) is essential for restoring anatomy and biomechanical stability of the calcaneus. This can be challenging due to the small target area and presence of neurovascular structures on the medial side. The aim was to evaluate the precision of positioning of the subchondral posterior facet screw and processus anterior calcanei screw with or without a Screw Targeting Clamp. The secondary aim was to evaluate the added value of peroperative 3D imaging over 2D radiographs alone. Twenty Anubifix™ embalmed, human anatomic lower limb specimens were used. A subchondral posterior facet screw and a processus anterior calcanei screw were placed using an extended lateral approach. A senior orthopedic trauma surgeon experienced in calcaneal fracture surgery and a senior resident with limited experience in calcaneal surgery performed screw fixation in five specimens with and in five specimens without the clamp. 2D lateral and axial radiographs and a 3D recording were obtained postoperatively. Anatomical dissection was performed postoperatively as a diagnostic golden standard in order to obtain the factual screw positions. Blinded assessment of quality of fixation was performed by two surgeons. In 2D, eight screws were considered malpositioned when placed with the targeting device versus nine placed freehand. In 3D recordings, two additional screws were malpositioned in each group as compared to the golden standard. As opposed to the senior surgeon, the senior resident seemed to get the best results using the Screw Targeting Clamp (number of malpositioned screws using freehand was eight, and using the targeting clamp five). In nine out of 20 specimens 3D images provided additional information concerning target area and intra-articular placement. Based on the 3D assessment, five additional screws would have required repositioning. Except for one, all screw positions were rated equally after dissection when compared with 3D examinations

  10. Frictional performance of ball screw

    International Nuclear Information System (INIS)

    Nakashima, Katuhiro; Takafuji, Kazuki

    1985-01-01

    As feed screws, ball screws have become to be adopted in place of trapezoidal threads. The structure of ball screws is complex, but those are the indispensable component of NC machine tools and machining centers, and are frequently used for industrial robots. As the problems in the operation of ball screws, there are damage, life and the performance related to friction. As to the damage and life, though there is the problem of the load distribution on balls, the results of the research on rolling bearings are applied. The friction of ball screws consists of the friction of balls and a spiral groove, the friction of a ball and a ball, the friction in a ball-circulating mechanism and the viscous friction of lubricating oil. It was decided to synthetically examine the frictional performance of ball screws, such as driving torque, the variation of driving torque, efficiency, the formation of oil film and so on, under the working condition of wide range, using the screws with different accuracy and the nuts of various circuit number. The experimental setup and the processing of the experimental data, the driving performance of ball screws and so on are reported. (Kako, I.)

  11. Kinematics of Planetary Roller Screw Mechanism considering Helical Directions of Screw and Roller Threads

    Directory of Open Access Journals (Sweden)

    Shangjun Ma

    2015-01-01

    Full Text Available Based on the differential principle of thread transmission, an analytical model considering helical directions between screw and roller threads in planetary roller screw mechanism (PRSM is presented in this work. The model is critical for the design of PRSM with a smaller lead and a bigger pitch to realize a higher transmission accuracy. The kinematic principle of planetary transmission is employed to analyze the PRSM with different screw thread and roller thread directions. In order to investigate the differences with different screw thread and roller thread directions, the numerical model is developed by using the software Adams to validate the analytical solutions calculated by the presented model. The results indicate, when the helical direction of screw thread is identical with the direction of roller thread, that the lead of PRSM is unaffected regardless of whether sliding between screw and rollers occurs or not. Only when the direction of screw thread is reverse to the direction of roller thread, the design of PRSM with a smaller lead can be realized under a bigger pitch. The presented models and numerical simulation method can be used to research the transmission accuracy of PRSM.

  12. Short Segment Fixation Versus Short Segment Fixation With Pedicle Screws at the Fracture Level for Thoracolumbar Burst Fracture

    Directory of Open Access Journals (Sweden)

    Anghel S

    2014-04-01

    Full Text Available Objective: The most prevailing surgical procedure in the treatment of thoracolumbar burst fractures, Short Segment Fixation (SSF, is often followed by loss of correction or hardware failure which may be significant enough to require another surgical intervention. In order to take advantage of its benefits but to avoid or diminish the risk and impact of associated drawbacks, some other alternatives have been lately developed among which we refer to short segment fixation with intermediate screws (SSF+IS. This article provides a comparative picture over the effectiveness of the two above-mentioned surgical treatments, focusing on their potential to prevent the loss of correction.

  13. A novel route for placing free flap pedicle from a palatal defect

    Directory of Open Access Journals (Sweden)

    Rajeev B Ahuja

    2014-01-01

    Full Text Available One of the better options available to repair a large palatal defect is by employing a free flap. Almost all the times such free flaps are plumbed to facial vessels. The greatest challenge in such cases is the placement of the pedicle from palatal shelf to recipient vessels because there is no direct route available. As majority of large palatal fistulae are encountered in operated cleft palates there is a possibility of routing the pedicle through a cleft in the maxillary arch or via pyriform aperture. When such a possibility doesn′t exist the pedicle is routed behind the maxillary arch. We describe a novel technique of pedicle placement through a maxillary antrostomy, in this case report, where a large palatal fistula in a 16 year old boy was repaired employing a free radial artery forearm flap. The direct route provided by maxillary antrostomy is considered the most expeditious of all possibilities mentioned above.

  14. OPEN SURGICAL VS. MINIMALLY INVASIVE TREATMENT OF THORACOLUMBAR AO FRACTURES TYPE A AND B1 IN A REFERENCE HOSPITAL

    Directory of Open Access Journals (Sweden)

    José Enrique Salcedo Oviedo

    Full Text Available ABSTRACT Objective: The thoracolumbar spine trauma represents 30% of spinal diseases. To compare the minimally invasive technique with the open technique in lumbar fractures. Method: A prospective, cross-sectional, comparative observational study, which evaluated the following variables: surgery time, length of hospital stay, transoperative bleeding, postoperative pain, analyzed by SPSS software using Student's t test with statistical significance of p ≥ 0.05, with 24 patients with single-level thoracolumbar fractures, randomly treated with percutaneous pedicle screws and by open technique with a transpedicular system. Results: The surgery time was 90 minutes for the minimally invasive technique and 60 minutes for the open technique, the bleeding was on average 50 cm3 vs. 400 cm3. The mean visual analogue scale for pain at 24 hours of surgery was 5 for the minimally invasive group vs. 8 for the open group. The number of fluoroscopic projections of pedicle screws was 220 in the minimally invasive technique vs. 100 in the traditional technique. Quantified bleeding was minimal for percutaneous access vs. 340 cm3 for the traditional system. The hospital discharge for the minimally invasive group was at 24 hours and at 72 hours for those treated with open surgery. Conclusions: It is a technique that requires longer surgical time, with reports of less bleeding, less postoperative pain and less time for hospital discharge, reasons why it is supposed to be a procedure that requires a learning curve, statistical significance with respect to bleeding, visual analogue scale for pain and showed no significant difference in the variables of surgical time.

  15. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    Science.gov (United States)

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  16. Sacroiliac Screw Fixation

    NARCIS (Netherlands)

    E.W. van den Bosch

    2003-01-01

    textabstractThe aim of this thesis is to evaluate three major aspects of the use of sacroiliac screws in patients with unstable pelvic ring fractures: the optimal technique for sacroiliac screw fixation, the reliability of peroperative fluoroscopy and the late results. We focused on the questions

  17. MR imaging of lumbar spondylolysis: signal intensity change in the pars interarticularis and adjacent structures

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Suk Whan; Lee, Ghi Jai; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    2001-05-01

    To assess changes in MR signal intensity in the pars interarticularis and adjacent structures in patients with lumbar spondylolysis. The MR images of 36 patients with lumbar spondylolysis, confirmed by plain radiographs, were retrospectively analyzed. Using a 1.0T unit, we evaluated the signal intensity of a total of 216 parts interarticulares and adjacent structures from L3 to L5, as seen on sagittal images, and differences between areas with and without spondylolysis. The signal intensity of T1-and T2-weighted images was graded 0(more hypointense than spinal body), 1(as isointense as spinal body), 2(more hyperintense than spinal body and more hypointense than epidural fat), or 3(as isointense as epidural fat). Signal intensity change in endplates and degree of spondylolisthesis were analyzed, and the relationship between these factors was determined. Spondylolysis was noted at L5 in 61 cases, at L4 in 22, and of L3 in no case. In three cases spondylolysis was unilateral, and in the remainder it was bilateral. The degree of signal intensity was the same on T1-and T2-weighted images, and no case was grade 0. Eighty-six of 133 areas without spondylolysis were grade 1, 43 were grade 2, and four were grade 3. In 42 of 47 cases, signal intensity change was localized at pedicles. Among 83 areas with spondylolysis,on the other hand, nine were grade 1, 48 were grade 2, and 26 were grade 3. Signal intensity change was most commonly observed at the pars interarticularis, pedicle, and lamina(50/74)({rho}<0.001). Signal intensity change at the pars interarticularis and adjacent structures was accompanied in most cases by degenerative endplate change(10/11) and spondylolisthesis(11/13)({rho}<0.001). In patients with spondylolysis, signal intensity was frequently higher at the pars interarticularis and adjacent structures, and is thought to have a close relationship with degenerative endplate change and spondylolisthesis. Increases in signal intensity at the pars

  18. MR imaging of lumbar spondylolysis: signal intensity change in the pars interarticularis and adjacent structures

    International Nuclear Information System (INIS)

    Jang, Suk Whan; Lee, Ghi Jai; Shim, Jae Chan; Kim, Ho Kyun

    2001-01-01

    To assess changes in MR signal intensity in the pars interarticularis and adjacent structures in patients with lumbar spondylolysis. The MR images of 36 patients with lumbar spondylolysis, confirmed by plain radiographs, were retrospectively analyzed. Using a 1.0T unit, we evaluated the signal intensity of a total of 216 parts interarticulares and adjacent structures from L3 to L5, as seen on sagittal images, and differences between areas with and without spondylolysis. The signal intensity of T1-and T2-weighted images was graded 0(more hypointense than spinal body), 1(as isointense as spinal body), 2(more hyperintense than spinal body and more hypointense than epidural fat), or 3(as isointense as epidural fat). Signal intensity change in endplates and degree of spondylolisthesis were analyzed, and the relationship between these factors was determined. Spondylolysis was noted at L5 in 61 cases, at L4 in 22, and of L3 in no case. In three cases spondylolysis was unilateral, and in the remainder it was bilateral. The degree of signal intensity was the same on T1-and T2-weighted images, and no case was grade 0. Eighty-six of 133 areas without spondylolysis were grade 1, 43 were grade 2, and four were grade 3. In 42 of 47 cases, signal intensity change was localized at pedicles. Among 83 areas with spondylolysis,on the other hand, nine were grade 1, 48 were grade 2, and 26 were grade 3. Signal intensity change was most commonly observed at the pars interarticularis, pedicle, and lamina(50/74)(ρ<0.001). Signal intensity change at the pars interarticularis and adjacent structures was accompanied in most cases by degenerative endplate change(10/11) and spondylolisthesis(11/13)(ρ<0.001). In patients with spondylolysis, signal intensity was frequently higher at the pars interarticularis and adjacent structures, and is thought to have a close relationship with degenerative endplate change and spondylolisthesis. Increases in signal intensity at the pars interarticularis and

  19. A comparison of the techniques of direct pars interarticularis repairs for spondylolysis and low-grade spondylolisthesis: a meta-analysis.

    Science.gov (United States)

    Mohammed, Nasser; Patra, Devi Prasad; Narayan, Vinayak; Savardekar, Amey R; Dossani, Rimal Hanif; Bollam, Papireddy; Bir, Shyamal; Nanda, Anil

    2018-01-01

    OBJECTIVE Spondylosis with or without spondylolisthesis that does not respond to conservative management has an excellent outcome with direct pars interarticularis repair. Direct repair preserves the segmental spinal motion. A number of operative techniques for direct repair are practiced; however, the procedure of choice is not clearly defined. The present study aims to clarify the advantages and disadvantages of the different operative techniques and their outcomes. METHODS A meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The following databases were searched: PubMed, Cochrane Library, Web of Science, and CINAHL ( Cumulative Index to Nursing and Allied Health Literature). Studies of patients with spondylolysis with or without low-grade spondylolisthesis who underwent direct repair were included. The patients were divided into 4 groups based on the operative technique used: the Buck repair group, Scott repair group, Morscher repair group, and pedicle screw-based repair group. The pooled data were analyzed using the DerSimonian and Laird random-effects model. Tests for bias and heterogeneity were performed. The I 2 statistic was calculated, and the results were analyzed. Statistical analysis was performed using StatsDirect version 2. RESULTS Forty-six studies consisting of 900 patients were included in the study. The majority of the patients were in their 2nd decade of life. The Buck group included 19 studies with 305 patients; the Scott group had 8 studies with 162 patients. The Morscher method included 5 studies with 193 patients, and the pedicle group included 14 studies with 240 patients. The overall pooled fusion, complication, and outcome rates were calculated. The pooled rates for fusion for the Buck, Scott, Morscher, and pedicle screw groups were 83.53%, 81.57%, 77.72%, and 90.21%, respectively. The pooled complication rates for the Buck, Scott, Morscher, and pedicle

  20. Complications of syndesmotic screw removal

    NARCIS (Netherlands)

    Schepers, Tim; van Lieshout, Esther M. M.; de Vries, Mark R.; van der Elst, Maarten

    2011-01-01

    Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw

  1. Long-term follow-up and patient satisfaction after reduction mammoplasty: Superomedial versus inferior pedicle

    Directory of Open Access Journals (Sweden)

    Mohamed Makboul

    2016-01-01

    Full Text Available Background: Surgery for hypertrophied breasts represents a challenge for plastic surgeons. The search for a good post-surgical cosmetic breast has led to the development of many techniques. Objectives for reduction mammoplasty are to achieve elevated, symmetrical breasts, a round shape, good projection, small cicatrices that are not very perceptible, and a lasting result. Patients and Methods: This study was carried out on sixty cases who had done reduction mammoplasty from January 2009 to December 2014. All patients were examined and were asked for late post-operative results and overall patients' satisfaction. Results: Long-term projection and contour of the breast were more satisfactory among patients who had superomedial pedicle with a statistically significant difference. No statistically significant difference was observed between patients underwent either superomedial or inferior pedicle reduction mammoplasty with regard to breast shape symmetry, nipple symmetry and sensation. The mean score for satisfaction was higher among patients who underwent superomedial pedicle rather than the inferior pedicle method. Conclusion: The superomedial pedicle shows better long-term cosmetic results.

  2. [Lumbar spondylosis].

    Science.gov (United States)

    Seichi, Atsushi

    2014-10-01

    Lumbar spondylosis is a chronic, noninflammatory disease caused by degeneration of lumbar disc and/or facet joints. The etiology of lumbar spondylosis is multifactorial. Patients with lumbar spondylosis complain of a broad variety of symptoms including discomfort in the low back lesion, whereas some of them have radiating leg pain or neurologenic intermittent claudication (lumbar spinal stenosis). The majority of patients with spondylosis and stenosis of the lumbosacral spine can be treated nonsurgically. Nonsteroidal anti-inflammatory drugs and COX-2 inhibitors are helpful in controlling symptoms. Prostaglandin, epidural injection, and transforaminal injection are also helpful for leg pain and intermittent claudication. Operative therapy for spinal stenosis or spondylolisthesis is reserved for patients who are totally incapacitated by their condition.

  3. Assessment of Lumbar Lordosis and Lumbar Core Strength in Information Technology Professionals.

    Science.gov (United States)

    Mehta, Roma Satish; Nagrale, Sanket; Dabadghav, Rachana; Rairikar, Savita; Shayam, Ashok; Sancheti, Parag

    2016-06-01

    Observational study. To correlate lumbar lordosis and lumbar core strength in information technology (IT) professionals. IT professionals have to work for long hours in a sitting position, which can affect lumbar lordosis and lumbar core strength. Flexicurve was used to assess the lumbar lordosis, and pressure biofeedback was used to assess the lumbar core strength in the IT professionals. All subjects, both male and female, with and without complaint of low back pain and working for two or more years were included, and subjects with a history of spinal surgery or spinal deformity were excluded from the study. Analysis was done using Pearson's correlation. For the IT workers, no correlation was seen between lumbar lordosis and lumbar core strength (r=-0.04); however, a weak negative correlation was seen in IT people who complained of pain (r=-0.12), while there was no correlation of lumbar lordosis and lumbar core in IT people who had no complains of pain (r=0.007). The study shows that there is no correlation of lumbar lordosis and lumbar core strength in IT professionals, but a weak negative correlation was seen in IT people who complained of pain.

  4. Diagnosis of lumbar central spinal stenosis by plain radiography

    International Nuclear Information System (INIS)

    Ilkko, E.

    1989-01-01

    The usefulness of plain radiography in the diagnosis of lumbar central spinal stenosis was studied in 116 patients using computed tomography (CT) as a reference. The most significant signs found in central spinal stenosis were short pedicles, high narrow intervertebral foramina, small interlaminar windows and deep posterior concavity of the vertebral bodies. The sensitivity of plain radiography in the diagnosis of central spinal stenosis as compared to CT was 66%, the specificity was 93% and the accuracy was 86%. The midsagittal and interpedicular diameters were measured from plain radiograms and were compared with corresponding CT diameters. In approximately half of the cases, the sagittal diameters were compatible. The maximum error was 6 mm. On average, the interpedicular distances were measured as too wide. The reliability of CT measurements were established by taking the measurements from the vertebral column of a moose calf, and then comparing these to the real measurements obtained with a calibrated ruler. The maximal differences were 2 mm. (author). 24 refs.; 8 figs.; 3 tabs

  5. Scaphoid Fracture Fixation with an Acutrak? Screw

    OpenAIRE

    Loving, Vilert A.; Richardson, Michael L.

    2015-01-01

    We report a case of fixation of a scaphoid fracture using an Acutrak? screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compression across a fracture as the screw is advanced, and gives the screw its unique appearance. This featur...

  6. In vitro evaluation of force-expansion characteristics in a newly designed orthodontic expansion screw compared to conventional screws

    Directory of Open Access Journals (Sweden)

    Oshagh Morteza

    2009-01-01

    Full Text Available Objective : Expansion screws like Hyrax, Haas and other types, produce heavy interrupted forces which are unfavorable for dental movement and could be harmful to the tooth and periodontium. The other disadvantage of these screws is the need for patient cooperation for their regular activation. The purpose of this study was to design a screw and compare its force- expansion curve with other types. Materials and Methods : A new screw was designed and fabricated in the same dimension, with conventional types, with the ability of 8 mm expansion (Free wire length: 12 mm, initial compression: 4.5 mm, spring wire diameter: 0.4 mm, spring diameter: 3 mm, number of the coils: n0 ine, material: s0 tainless steel. In this in vitro study, the new screw was placed in an acrylic orthodontic appliance, and after mounting on a stone cast, the force-expansion curve was evaluated by a compression test machine and compared to other screws. Results : Force-expansion curve of designed screw had a flatter inclination compared to other screws. Generally it produced a light continuous force (two to 3.5 pounds for every 4 mm of expansion. Conclusion : In comparison with heavy and interrupted forces of other screws, the newly designed screw created light and continuous forces.

  7. Diaphragmatic hernia repair using a rectus abdominis muscle pedicle flap in three dogs.

    Science.gov (United States)

    Chantawong, P; Komin, K; Banlunara, W; Kalpravidh, M

    2013-01-01

    To report the clinical use of a pedicle flap from the rectus abdominis muscle to repair extensive diaphragmatic tears in dogs with diaphragmatic hernia. Three dogs with a combination of radial and circumferential diaphragmatic tears were studied. The circumferential tear was repaired by suturing the wound edge with the edge at the abdominal wall. A pedicle flap of the rectus abdominis muscle was used for repairing the radial tear. The dogs were examined radiographically for lung and diaphragm appearance and evidence of reherniation at 10 days, and at one, two, and four months after surgery, and fluoroscopically for paradoxical motion of the diaphragm at one and four months. The rectus abdominis muscle pedicle flap was successfully used in all three dogs. The animals recovered uneventfully without evidence of reherniation during the four follow-up months. Fluoroscopic examination revealed no paradoxical motion of the diaphragm. A rectus abdominis muscle pedicle flap can be used for repairing large diaphragmatic defects in dogs.

  8. Geothermal ORC Systems Using Large Screw Expanders

    OpenAIRE

    Biederman, Tim R.; Brasz, Joost J.

    2014-01-01

    Geothermal ORC Systems using Large Screw Expanders Tim Biederman Cyrq Energy Abstract This paper describes a low-temperature Organic Rankine Cycle Power Recovery system with a screw expander a derivative of developed of Kaishan's line of screw compressors, as its power unit. The screw expander design is a modified version of its existing refrigeration compressor used on water-cooled chillers. Starting the ORC development program with existing refrigeration screw compre...

  9. The applicability of PEEK-based abutment screws.

    Science.gov (United States)

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter

    2016-10-01

    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. LUMBAR CORSETS CAN DECREASE LUMBAR MOTION IN GOLF SWING

    Directory of Open Access Journals (Sweden)

    Koji Hashimoto

    2013-03-01

    Full Text Available Swinging a golf club includes the rotation and extension of the lumbar spine. Golf-related low back pain has been associated with degeneration of the lumbar facet and intervertebral discs, and with spondylolysis. Reflective markers were placed directly onto the skin of 11young male amateur golfers without a previous history of back pain. Using a VICON system (Oxford Metrics, U.K., full golf swings were monitored without a corset (WOC, with a soft corset (SC, and with a hard corset (HC, with each subject taking 3 swings. Changes in the angle between the pelvis and the thorax (maximum range of motion and angular velocity in 3 dimensions (lumbar rotation, flexion-extension, and lateral tilt were analyzed, as was rotation of the hip joint. Peak changes in lumbar extension and rotation occurred just after impact with the ball. The extension angle of the lumbar spine at finish was significantly lower under SC (38° or HC (28° than under WOC (44° conditions (p < 0.05. The maximum angular velocity after impact was significantly smaller under HC (94°/sec than under SC (177°/sec and WOC (191° /sec conditions, as were the lumbar rotation angles at top and finish. In contrast, right hip rotation angles at top showed a compensatory increase under HC conditions. Wearing a lumbar corset while swinging a golf club can effectively decrease lumbar extension and rotation angles from impact until the end of the swing. These effects were significantly enhanced while wearing an HC

  11. Lumbar paraspinal muscle morphometry and its correlations with demographic and radiological factors in adult isthmic spondylolisthesis: a retrospective review of 120 surgically managed cases.

    Science.gov (United States)

    Thakar, Sumit; Sivaraju, Laxminadh; Aryan, Saritha; Mohan, Dilip; Sai Kiran, Narayanam Anantha; Hegde, Alangar S

    2016-05-01

    OBJECTIVE The objective of this study was to assess the cross-sectional areas (CSAs) of lumbar paraspinal muscles in adults with isthmic spondylolisthesis (IS), to compare them with those in the normative population, and to evaluate their correlations with demographic factors and MRI changes in various spinal elements. METHODS The authors conducted a retrospective study of patients who had undergone posterior lumbar interbody fusion for IS, and 2 of the authors acting as independent observers calculated the CSAs of various lumbar paraspinal muscles (psoas, erector spinae [ES], multifidus [MF]) on preoperative axial T2-weighted MR images from the L-3 to L-5 vertebral levels and computed the CSAs as ratios with respect to the corresponding vertebral body areas. These values were then compared with those in an age- and sex-matched normative population and were analyzed with respect to age, sex, duration of symptoms, grade of listhesis, and various MRI changes at the level of the listhesis (pedicle signal change, disc degeneration, and facetal arthropathy). RESULTS Compared with values in normative controls, the mean CSA value for the ES muscle was significantly higher in the study cohort of 120 patients (p = 0.002), whereas that for the MF muscle was significantly lower (p = 0.009), and more so in the patients with PSC (p = 0.002). Magnetic resonance imaging signal change in the pedicle was seen in half of the patients, all of whom demonstrated a Type 2 change. Of the variables tested in a multivariate analysis, age independently predicted lower area values for all 3 muscles (p ≤ 0.001), whereas female sex predicted a lower mean psoas area value (p < 0.001). None of the other variables significantly predicted any of the muscle area values. A decrease in the mean MF muscle area value alone was associated with a significantly increased likelihood of a PSC (p = 0.039). CONCLUSIONS Compared with normative controls, patients with IS suffer selective atrophy of their MF

  12. The Omental Pedicle Flap in Dogs Revised and Refined: A Cadaver Study.

    Science.gov (United States)

    Doom, Marjan; Cornillie, Pieter; Simoens, Paul; Huyghe, Stephanie; de Rooster, Hilde

    2016-08-01

    To expand current knowledge on the canine omental vasculature and refine the existing lengthening technique of the canine omentum. Ex vivo study. Canine cadavers (n=20). In 10 canine cadavers the omental arteries were mapped using intravascular latex injection and these results were used to create an omental pedicle flap based on the splenic artery in 10 additional cadavers. The operating range of the flap was recorded with particular attention to the main regions of interest for omental transposition in dogs (axillary and inguinal regions). The superficial and deep omental leaves were each predominantly supplied by a left and a right marginal omental artery that anastomosed near the caudal omental border into a superficial and a deep omental arch, respectively. Anastomoses between arteries of the superficial and the deep omental leaves were weak and inconsistent, except for 1 anastomosis that was found in 8 of 10 dogs. By transposing the intact omentum, the right axilla could be reached in 3 dogs, both axillae in 1 dog, and both groins in all cadavers. In all cases, the omental pedicle reached to and beyond the axillary and inguinal regions. By unfolding the pedicle leaves, the width of the pedicle tip could be doubled. When lengthening the omentum is necessary to reach extra-abdominal structures, the omental pedicle flap based on the splenic artery appears to preserve the omental vascular supply. These observations warrant further clinical trials to evaluate this new omtental flap technique in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.

  13. The influence of lumbar extensor muscle fatigue on lumbar-pelvic coordination during weightlifting.

    Science.gov (United States)

    Hu, Boyi; Ning, Xiaopeng

    2015-01-01

    Lumbar muscle fatigue is a potential risk factor for the development of low back pain. In this study, we investigated the influence of lumbar extensor muscle fatigue on lumbar-pelvic coordination patterns during weightlifting. Each of the 15 male subjects performed five repetitions of weightlifting tasks both before and after a lumbar extensor muscle fatiguing protocol. Lumbar muscle electromyography was collected to assess fatigue. Trunk kinematics was recorded to calculate lumbar-pelvic continuous relative phase (CRP) and CRP variability. Results showed that fatigue significantly reduced the average lumbar-pelvic CRP value (from 0.33 to 0.29 rad) during weightlifting. The average CRP variability reduced from 0.17 to 0.15 rad, yet this change ws statistically not significant. Further analyses also discovered elevated spinal loading during weightlifting after the development of lumbar extensor muscle fatigue. Our results suggest that frequently experienced lumbar extensor muscle fatigue should be avoided in an occupational environment. Lumbar extensor muscle fatigue generates more in-phase lumbar-pelvic coordination patterns and elevated spinal loading during lifting. Such increase in spinal loading may indicate higher risk of back injury. Our results suggest that frequently experienced lumbar muscle fatigue should be avoided to reduce the risk of LBP.

  14. Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

    Directory of Open Access Journals (Sweden)

    Jesse Chieh-Szu Yang

    Full Text Available Fixation with a dynamic hip screw (DHS is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw' to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03. Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12. However, the patient's implanted with a DHS did display significantly greater migration (P<0.001 than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

  15. Comparison of effectiveness between cork-screw and peg-screw electrodes for transcranial motor evoked potential monitoring using the finite element method.

    Science.gov (United States)

    Tomio, Ryosuke; Akiyama, Takenori; Ohira, Takayuki; Yoshida, Kazunari

    2016-01-01

    Intraoperative monitoring of motor evoked potentials by transcranial electric stimulation is popular in neurosurgery for monitoring motor function preservation. Some authors have reported that the peg-screw electrodes screwed into the skull can more effectively conduct current to the brain compared to subdermal cork-screw electrodes screwed into the skin. The aim of this study was to investigate the influence of electrode design on transcranial motor evoked potential monitoring. We estimated differences in effectiveness between the cork-screw electrode, peg-screw electrode, and cortical electrode to produce electric fields in the brain. We used the finite element method to visualize electric fields in the brain generated by transcranial electric stimulation using realistic three-dimensional head models developed from T1-weighted images. Surfaces from five layers of the head were separated as accurately as possible. We created the "cork-screws model," "1 peg-screw model," "peg-screws model," and "cortical electrode model". Electric fields in the brain radially diffused from the brain surface at a maximum just below the electrodes in coronal sections. The coronal sections and surface views of the brain showed higher electric field distributions under the peg-screw compared to the cork-screw. An extremely high electric field was observed under cortical electrodes. Our main finding was that the intensity of electric fields in the brain are higher in the peg-screw model than the cork-screw model.

  16. Lumbar spine MRI in the elite-level female gymnast with low back pain

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, D. Lee [Department of Radiology, University of Iowa, Roy J. and Lucille A. Carver College of Medicine, Iowa City, IA (United States); Department of Radiology, Michigan State University, Colleges of Human Medicine and Osteopathic Medicine, East Lansing, MI (United States); Nassar, Lawrence [Department of Sports Medicine and Kinesiology, Michigan State University, College of Osteopathic Medicine, East Lansing, MI (United States); DeLano, Mark C. [Department of Radiology, Michigan State University, Colleges of Human Medicine and Osteopathic Medicine, East Lansing, MI (United States)

    2006-07-15

    Previous studies have shown increased degenerative disk changes and spine injuries in the competitive female gymnast. However, it has also been shown that many of these findings are found in asymptomatic athletic people of the same age. Previous magnetic resonance imaging (MRI) studies evaluating the gymnastic spine have not made a distinction between symptomatic and asymptomatic athletes. Our hypothesis is that MRI will demonstrate the same types of abnormalities in both the symptomatic and asymptomatic gymnasts. Olympic-level female gymnasts received prospectively an MRI exam of the lumbar spine. Each of the gymnasts underwent a physical exam by a sports medicine physician just prior to the MRI for documentation of low back pain. Each MRI exam was evaluated for anterior apophyseal ring avulsion injury, compression deformity of the vertebral body, spondylolysis, spondylolisthesis, degenerative disease, focal disk protrusion/extrusion, muscle strain, epidural mass, and bone-marrow edema. Nineteen Olympic-level female gymnasts (age 12-20 years) were evaluated prospectively in this study. All of these gymnasts were evaluated while attending a specific training camp. Anterior ring apophyseal injuries (9/19) and degenerative disk disease (12/19) were common. Spondylolysis (3/19) and spondylolisthesis (3/19) were found. Focal bone-marrow edema was found in both L3 pedicles in one gymnast. History and physical exam revealed four gymnasts with current low back pain at the time of imaging. There were findings confined to those athletes with current low back pain: spondylolisthesis, spondylolysis, bilateral pedicle bone-marrow edema, and muscle strain. (orig.)

  17. Lumbar spine MRI in the elite-level female gymnast with low back pain

    International Nuclear Information System (INIS)

    Bennett, D. Lee; Nassar, Lawrence; DeLano, Mark C.

    2006-01-01

    Previous studies have shown increased degenerative disk changes and spine injuries in the competitive female gymnast. However, it has also been shown that many of these findings are found in asymptomatic athletic people of the same age. Previous magnetic resonance imaging (MRI) studies evaluating the gymnastic spine have not made a distinction between symptomatic and asymptomatic athletes. Our hypothesis is that MRI will demonstrate the same types of abnormalities in both the symptomatic and asymptomatic gymnasts. Olympic-level female gymnasts received prospectively an MRI exam of the lumbar spine. Each of the gymnasts underwent a physical exam by a sports medicine physician just prior to the MRI for documentation of low back pain. Each MRI exam was evaluated for anterior apophyseal ring avulsion injury, compression deformity of the vertebral body, spondylolysis, spondylolisthesis, degenerative disease, focal disk protrusion/extrusion, muscle strain, epidural mass, and bone-marrow edema. Nineteen Olympic-level female gymnasts (age 12-20 years) were evaluated prospectively in this study. All of these gymnasts were evaluated while attending a specific training camp. Anterior ring apophyseal injuries (9/19) and degenerative disk disease (12/19) were common. Spondylolysis (3/19) and spondylolisthesis (3/19) were found. Focal bone-marrow edema was found in both L3 pedicles in one gymnast. History and physical exam revealed four gymnasts with current low back pain at the time of imaging. There were findings confined to those athletes with current low back pain: spondylolisthesis, spondylolysis, bilateral pedicle bone-marrow edema, and muscle strain. (orig.)

  18. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Directory of Open Access Journals (Sweden)

    Herrera Antonio

    2010-06-01

    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  19. [Comparison of pedicle and free tissue transfers in the German DRG system].

    Science.gov (United States)

    Lotter, O; Stahl, S; Hohenstein, C; Schaller, H-E; Jaminet, P

    2011-12-01

    Diagnosis-Related Groups (DRGs) are a patient classification system grouping related types of patients to the resources they have consumed. In this analysis, we compared pedicle and free flaps in plastic and reconstructive surgery in the actual German DRG system. After grouping common flaps while systematically modifying the diagnosis, the operative procedure(s), and the receptor site, reimbursement and thresholds of length of stay were identified. The mean value of the average length of stay was higher in free flaps as compared to pedicle flaps (15 vs. 9 days) and the mean reimbursement in free flaps was almost twice as high as in pedicle flaps (8 936 € vs. 4 582 €). Regarding the diagnosis, third-grade open fractures in pedicle flaps and full-thickness burns in free flaps are in the vanguard of reimbursement. Higher DRG conformity is generally found with free flaps. Different possibilities in coding the procedures and the strong dependence on the underlying diagnosis lead to variations of remuneration and length of stay, which are not explainable and sometimes even seem paradoxical. Furthermore, mixed calculation creates DRGs that lose the ability to describe the real effort. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Utility of Glissonean Pedicle Transection for Surgical Treatment of Severe Liver Trauma

    Directory of Open Access Journals (Sweden)

    Satoshi Koizumi

    2017-04-01

    Full Text Available The most common initial strategy for treatment of severe liver trauma is damage control in which hemostasis is achieved by perihepatic gauze packing and/or vascular embolization. However, we encounter patients in whom this strategy alone is not adequate. We have applied the principles of Glissonean pedicle transection, a technique that was originally devised to ensure safe and quick performance of planned hepatectomy for liver cancer, to 3 cases of severe liver trauma. We performed Glissonean pedicle ligation during damage control surgery in 2 patients and Glissonean pedicle transection during the definitive surgery in 1 patient. We describe the approaches and our experience with them, including operation times and outcomes. From our experience thus far, it seems that 8–12 h after the damage control procedure is appropriate for performing the definitive surgery. Although there are some problems posed by this strategy and cases to which it will not be applicable, the method seems to be particularly useful for cases of severe liver trauma in which the damage is extensive and involves the Glissonean pedicles near the hepatic hilus. We describe our 3 cases in detail and review our experience in light of the available literature.

  1. Comparison of open reduction versus minimally invasive surgical approaches on screw position in canine sacroiliac lag-screw fixation.

    Science.gov (United States)

    Déjardin, Loïc M; Marturello, Danielle M; Guiot, Laurent P; Guillou, Reunan P; DeCamp, Charles E

    2016-07-19

    To compare accuracy and consistency of sacral screw placement in canine pelves treated for sacroiliac luxation with open reduction and internal fixation (ORIF) or minimally invasive osteosynthesis (MIO) techniques. Unilateral sacroiliac luxations created experimentally in canine cadavers were stabilized with an iliosacral lag screw applied via ORIF or MIO techniques (n = 10/group). Dorsoventral and craniocaudal screw angles were measured using computed tomography multiplanar reconstructions in transverse and dorsal planes, respectively. Ratios between pilot hole length and sacral width (PL/SW-R) were obtained. Data between groups were compared statistically (p sacroiliac luxations provides more accurate and consistent sacral screw placement than ORIF. With proper techniques, iatrogenic neurological damage can be avoided with both techniques. The PL /SW-R, which relates to safe screw fixation, also demonstrates that screw penetration of at least 60% of the sacral width is achievable regardless of surgical approach. These findings, along with the limited dissection needed for accurate sacral screw placement, suggest that MIO of sacroiliac luxations is a valid alternative to ORIF.

  2. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  3. Combined posteroanterior fusion versus transforaminal lumbar interbody fusion (TLIF) in thoracolumbar burst fractures.

    Science.gov (United States)

    Schmid, Rene; Lindtner, Richard Andreas; Lill, Markus; Blauth, Michael; Krappinger, Dietmar; Kammerlander, Christian

    2012-04-01

    The optimal treatment strategy for burst fractures of the thoracolumbar junction is discussed controversially in the literature. Whilst 360° fusion has shown to result in better radiological outcome, recent studies have failed to show its superiority concerning clinical outcome. The morbidity associated with the additional anterior approach may account for these findings. The aim of this prospective observational study was therefore to compare two different techniques for 360° fusion in thoracolumbar burst fractures using either thoracoscopy or a transforaminal approach (transforaminal lumbar interbody fusion (TLIF)) to support the anterior column. Posterior reduction and short-segmental fixation using angular stable pedicle screw systems were performed in all patients as a first step. Monocortical strut grafts were used for the anterior support in the TLIF group, whilst tricortical grafts or titanium vertebral body replacing implants of adjustable height were used in the combined posteroanterior group. At final follow-up, the radiological outcome was assessed by performing X-rays in a standing position. The clinical outcome was measured using five validated outcome scores. The morbidity associated with the approaches and the donor site was assessed as well. There were 21 patients in the TLIF group and 14 patients in the posteroanterior group included. The postoperative loss of correction was higher in the TLIF group (4.9°±8.3° versus 3.4°±6.4°, p>0.05). There were no significant differences regarding the outcome scores between the two groups. There were no differences in terms of return to employment, leisure activities and back function either. More patients suffered from donor-site morbidity in the TLIF group, whilst the morbidity associated with the surgical approach was higher in the posteroanterior group. The smaller donor-site morbidity in the posteroanterior group is counterbalanced by an additional morbidity associated with the anterior approach

  4. Standard Waste Box Lid Screw Removal Option Testing

    International Nuclear Information System (INIS)

    Anast, Kurt Roy

    2016-01-01

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  5. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  6. Misplaced Cervical Screws Requiring Reoperation.

    Science.gov (United States)

    Peterson, Jeremy C; Arnold, Paul M; Smith, Zachary A; Hsu, Wellington K; Fehlings, Michael G; Hart, Robert A; Hilibrand, Alan S; Nassr, Ahmad; Rahman, Ra'Kerry K; Tannoury, Chadi A; Tannoury, Tony; Mroz, Thomas E; Currier, Bradford L; De Giacomo, Anthony F; Fogelson, Jeremy L; Jobse, Bruce C; Massicotte, Eric M; Riew, K Daniel

    2017-04-01

    A multicenter, retrospective case series. In the past several years, screw fixation of the cervical spine has become commonplace. For the most part, this is a safe, low-risk procedure. While rare, screw backout or misplaced screws can lead to morbidity and increased costs. We report our experiences with this uncommon complication. A multicenter, retrospective case series was undertaken at 23 institutions in the United States. Patients were included who underwent cervical spine surgery from January 1, 2005, to December 31, 2011, and had misplacement of screws requiring reoperation. Institutional review board approval was obtained at all participating institutions, and detailed records were sent to a central data center. A total of 12 903 patients met the inclusion criteria and were analyzed. There were 11 instances of screw backout requiring reoperation, for an incidence of 0.085%. There were 7 posterior procedures. Importantly, there were no changes in the health-related quality-of-life metrics due to this complication. There were no new neurologic deficits; a patient most often presented with pain, and misplacement was diagnosed on plain X-ray or computed tomography scan. The most common location for screw backout was C6 (36%). This study represents the largest series to tabulate the incidence of misplacement of screws following cervical spine surgery, which led to revision procedures. The data suggest this is a rare event, despite the widespread use of cervical fixation. Patients suffering this complication can require revision, but do not usually suffer neurologic sequelae. These patients have increased cost of care. Meticulous technique and thorough knowledge of the relevant anatomy are the best means of preventing this complication.

  7. Effect of aging and lumbar spondylosis on lumbar lordosis

    Directory of Open Access Journals (Sweden)

    Francis Osita Okpala

    2018-01-01

    Full Text Available Background: Lumbar lordosis (LL, the anterior convexity of the lumbar spine in the mid-sagittal plane, gives the spine some resilience and helps in protecting it from compressive forces because some of the force is taken by the anterior longitudinal ligaments. In aging and lumbar spondylosis, the intervertebral discs undergo the same degenerative changes though at different rates, and in both, while some authors reported a straightening of LL, others reported no significant change. This morphologic information would hopefully influence therapeutic decision-making, particularly in lumbar spondylosis, which though usually asymptomatic, is a common cause of low back pain. Aim: The aim of the study was to investigate the effect of aging and lumbar spondylosis on LL. Subjects and Methods: Lumbosacral joint angle (LSJA, an angular measure of LL, was retrospectively measured in 252 normal and 329 spondylotic adolescent and adult supine lateral lumbosacral spine archival radiographs, and data were analyzed with IBM SPSS Statistics 23.0 (New York, USA. Results: Normal LSJA range was 5°–39°; the mean was 18.7° and showed insignificant variation with gender and aging. Spondylotic range was 5°–40° and the mean (20.8° differed from the normal mean by about 2°, which probably have inconsequential effect on the lumbar curvature, suggesting that the normal and spondylotic mean values are essentially equal. The spondylotic mean also showed insignificant variation with aging and inconsequential 1° gender difference in favor of females. Conclusion: LL is substantially maintained in aging and lumbar spondylosis.

  8. Isolated unilateral vertebral pedicle fracture caused by a back massage in an elderly patient: a case report and literature review.

    Science.gov (United States)

    Guo, Zhiping; Chen, Wei; Su, Yanling; Yuan, Junhui; Zhang, Yingze

    2013-11-01

    The vertebral pedicle injuries are clinically common. However, the isolated vertebral pedicle fracture with intact vertebral bodies is a rare lesion. We reported a case of a 66-year-old man who experienced a pedicle fracture after a back massage. The patient sustained osteoporosis, long-existing low back pain and nerve compression symptoms without antecedent major trauma. Imaging findings demonstrated an isolated unilateral L5 vertebral pedicle fracture with intact vertebral bodies, spinal canal stenosis at the L4-5 levels, bulging annulus fibrosus at the L4-S1 levels, bilateral spondylolysis and an L5/S1 spondylolisthesis. The patient underwent L4-S1 decompressive laminectomy, L5/S1 discectomy and neurolysis, and reduction and fixation of the L5 vertebral pedicle fracture and L5/S1 spondylolisthesis using the pedicle nail system. At follow-ups, the patient showed good recovery without pain or numbness in the low back and bilateral lower extremities. This study raises the awareness of a complication of alternative medicine and the possibility of a pedicle fracture caused by a low-energy trauma.

  9. Long constructs in the thoracic and lumbar spine with a minimally invasive technique.

    Science.gov (United States)

    Roldan, H; Perez-Orribo, L; Spreafico, M; Ginoves-Sierra, M

    2011-04-01

    Literature about long implants used together with a minimally invasive spine surgery (MISS) technique is scarce. Our objective is to contribute our surgical experience in this field and to specifically focus on several technical details. A digitally-dissected canal along the paravertebral muscles was created linking the stab wounds on each side in relation with the pedicles to be cannulated. Screws were inserted following the percutaneous technique. Long rods were modelled, threaded through the extender sleeves along the paravertebral canal and pushed into the screw heads with the reduction forceps. When fusion was needed, the facet complex was decorticated with a drill. To insert a cross-link, a canal between the 2 rods was digitally created and the spinous process was drilled. 8 patients underwent surgery (age range: 25-77 years). Indications were postosteomyelitis kyphosis in 3 patients, bone tumor in 3, and spine fracture in 2. No blood transfusions were necessary during or after surgery. A cross-link was inserted in 2 patients. Posterolateral bone fusion was attempted in 4, but radiologically identifiable in none. In one patient a cantilever manoeuvre was done to correct kyphosis. Mean duration of surgery was 4 h. There were no clinical complications related to the operation or the hardware (mean follow-up of 7.14 months, range: 1-15 months). The application of MISS techniques can be broadened to long spinal constructs to assess fractures, tumors or deformity, especially in elderly or debilitated patients. Nevertheless, posterolateral fusion is still a challenge through these limited exposures. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Tricortical cervical inter-body screw fixation.

    Directory of Open Access Journals (Sweden)

    Goel A

    1997-01-01

    Full Text Available A new tricortical method of screw implantation for anterior cervical interbody plate fixation is described. The screws are placed obliquely such that they engage the anterior cortex of the body and traverse through the cortices adjoining the disc space. By this method the screws not only hold the plate firmly with a tricortical purchase, but by virtue of their course stabilize the two adjoining vertebral bodies by themselves. Sixteen patients were treated by this method. In three of these cases only tricortical screws without the metal plate were used for fixation. The advantages of the technique are discussed.

  11. Osteonecrosis of femoral head: Treatment by core decompression and vascular pedicle grafting

    Directory of Open Access Journals (Sweden)

    Babhulkar Sudhir

    2009-01-01

    Full Text Available Background: Femoral head-preserving core decompression and bone grafting have shown excellent result in preventing collapse. The use of vascularized grafts have shown better clinical results. The vascular pedicle bone graft is an easy to perform operation and does not require special equipment. We analyzed and report a series of patients of osteonecrosis of femoral head treated by core decompression and vascular pedicle grafting of part of iliac crest based on deep circumflex iliac vessels. Materials and Methods: The article comprises of the retrospective study of 31 patients of osteonecrosis of femoral head in stage II and III treated with core decompression and vascular pedicle grafting by using part of iliac crest with deep circumflex iliac vessels from January 1990 to December 2005. The young patients with a mean age 32 years (18-52 years with a minimum follow-up of five years were included for analysis. Sixteen patients had osteonecrosis following alcohol abuse, 12 patients following corticosteroid consumption, 3 patients had idiopathic osteonecrosis. Nine patients were stage IIB, and 22 patients were stage IIIC according to ARCO′s system. The core decompression and vascular pedicle grafting was performed by anterior approach by using part of iliac crest with deep circumflex iliac vessels. Results: Digital subtraction arteriography performed in 9 patients at the end of 12 weeks showed the patency of deep circumflex artery in all cases, and bone scan performed in 6 other patients showed high uptake in the grafted area of the femoral head proving the efficacy of the operative procedure. Out of 31 patients, only one patient progressed to collapse and total joint replacement was advised. At the final follow up period of 5-8 years, Harris Hip Score improved mean ± SD of 28.2 ± 6.4 ( p < 0.05. Forty-eight percent of patients had an improvement in Harris Hip Score of more that 28 points. Conclusion: The core decompression and vascular pedicle

  12. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  13. The effect of intraosseous injection of calcium sulfate on microstructure and biomechanics of osteoporotic lumbar vertebrae in sheep

    Directory of Open Access Journals (Sweden)

    Da LIU

    2014-10-01

    Full Text Available Objective To investigate the effect of calcium sulfate (CS on improvement of microstructure and biomechanical performance of osteoporotic lumbar vertebrae in sheep. Methods Osteoporosis model was reproduced in 8 female sheep by bilateral ovariectomy and methylprednisolone administration. Then the lumbar vertebrae (L1-L4 in each sheep were randomly divided into CS group and blank group (2 vertebrae in each sheep. CS was injected into the vertebral bodies through the pedicle in CS group, and no treatment was given in blank group. All of the animals were sacrificed 3 months later, and vertebrae L1-L4 were harvested. The microstructure and biomechanical performance of vertebral bodies were assessed by micro-CT scanning, histological observation and biomechanical test. Results After ovariectomy and methylprednisolone administration, the mean bone mineral density of the lumbar vertebrae in the sheep was significantly decreased (>25% compared with that before induction (P<0.05, demonstrating a successful reproduction of osteoporosis model. Three months after injection, it was shown that CS was completely degraded without any remnant in the bone tissue. The quality of the bone tissue (trabecular number and tissue mineral density in CS group was significantly better than that in blank group (P<0.05, and the biomechanical performance in CS group was significantly superior to that in blank group (P<0.05. Conclusions  Local injection of CS could significantly improve the microstructure and biomechanical performance of osteoporotic vertebrae, and it may decrease the risk of fracture of patients with osteoporosis. DOI: 10.11855/j.issn.0577-7402.2014.09.02

  14. Risk factors for pedicled flap necrosis in hand soft tissue reconstruction: a multivariate logistic regression analysis.

    Science.gov (United States)

    Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun

    2018-03-01

    Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.

  15. Two-Stage Surgical Management of Multilevel Symptomatic Thoracic Haemangioma Using Ethanol and Iliac Crest Bone Graft

    Science.gov (United States)

    Brahmajoshyula, Venkatramana; Mayi, Shivanand; Teegala, Suman

    2014-01-01

    This article presents a 56-year-old obese female who presented with back pain and progressive weakness in her lower limbs for three months. She was bed-ridden for one week before reporting to our hospital. Plain radiographs showed vertical striations in multiple vertebrae classical of haemangioma. Magnetic resonance imaging (MRI) spine revealed multiple thoracic and lumbar vertebral haemangiomas. Extra osseous extension of haemangioma at T12 was causing spinal cord compression. Two-stage surgery was performed with absolute alcohol (ethanol) injection followed by pedicle screw fixation and decompression with tricortical iliac crest bone graft into the vertebral body. Postoperatively rapid neurological improvement was seen. After three weeks, she could walk independently. One year later, computed tomography showed complete incorporation of bone graft and maintained vertebral body height. MRI showed complete resolution of the cord edema at T12. These findings indicated diminished vascularity of the tumor. PMID:25187869

  16. Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.

    Science.gov (United States)

    Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen

    2011-05-01

    To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  17. Omental pedicle transposition and suture repair of peripheral nerve ...

    African Journals Online (AJOL)

    Abu wael

    This study aimed to compare the effectiveness of omental pedicle transposition and ... Assessment of the nerve regeneration was based on functional (motor and sensory), ..... peripheral nerve fibers regenerating after crush, multiple crush, and.

  18. Management of rigid post-traumatic kyphosis.

    Science.gov (United States)

    Wu, S S; Hwa, S Y; Lin, L C; Pai, W M; Chen, P Q; Au, M K

    1996-10-01

    Rigid post-traumatic kyphosis after fracture of the thoracolumbar and lumbar spine represents a failure of initial management of the injury. Kyphosis moves the center of gravity anterior. The kyphosis and instability may result in pain, deformity, and increased neurologic deficits. Management for symptomatic post-traumatic kyphosis always has presented a challenge to orthopedic surgeons. To evaluate the surgical results of one stage posterior correction for rigid symptomatic post-traumatic kyphosis of the thoracolumbar and lumbar spine. The management for post-traumatic kyphosis remains controversial. Anterior, posterior, or combined anterior and posterior procedures have been advocated by different authors and show various degrees of success. One vertebra immediately above and below the level of the deformity was instrumented posteriorly by a transpedicular system (internal fixator AO). Posterior decompression was performed by excision of the spinal process and bilateral laminectomy. With the deformed vertebra through the pedicle, the vertebral body carefully is removed around the pedicle level, approximating a wedge shape. The extent to which the deformed vertebral body should be removed is determined by the attempted correction. Correction of the deformity is achieved by manipulation of the operating table and compression of the adjacent Schanz screws above and below the lesion. Thirteen patients with post-traumatic kyphosis with symptoms of fatigue and pain caused by slow progression of kyphotic deformities received posterior decompression, correction, and stabilization as a definitive treatment. The precorrection kyphosis ranged from 30-60 degrees, with a mean of 40 degrees +/- 10.8 degrees. After correction, kyphosis was reduced to an average of 1.5 degrees +/- 3.8 degrees, with a range from -5 degrees to 5 degrees. The average angle of correction was 38.8 degrees +/- 10.4 degrees, with a range from 25 degrees to 60 degrees. Significant difference was found

  19. [Clinical application of three-dimensional O-arm navigation system in treating patients with dystrophic scoliosis secondary to neurofibromatosis type Ⅰ].

    Science.gov (United States)

    Liu, Z; Qiu, Y; Li, Y; Zhao, Z H; Wang, B; Zhu, F; Yu, Y; Sun, X; Zhu, Z Z

    2017-03-01

    Objective: To investigate the clinical outcomes and the accuracy of O-arm-navigation system assisted pedicle screw insertion in dystrophic scoliosis secondary to neurofibromatosis type Ⅰ(NF-1). Methods: A retrospective study was conducted in 41 patients with dystrophic NF-1-associated thoracic scoliosis who were surgically treated at Department of Orthopaedics, Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School between June 2012 and October 2014 with more than 18 months follow-up. The patients were then divided into two groups: 18 patients were under the assistance of O-arm-navigation-based pedicle screw insertion (O-arm group) and the remaining 23 patients' pedicle screws insertion were conducted by free-hand (free-hand group). The X-ray and CT were analyzed to investigate the correction rate and safety of pedicle insertion. t -test was used to analyze measurement data and χ(2) test was used to analyze accuracy of screw insertion between the two groups. Results: The mean coronal Cobb angle was 63.2°±8.7° in the O-arm group and 66.9°±7.4° in the free-hand group ( P >0.05), which was then corrected into 23.1°±6.8° and 30.2°±7.6°( t =2.231, P =0.031) after surgery respectively.Operation time was (265.0±70.3)minutes and estimated blood loss was (1 024±465)ml in the O-arm group. Operation time and estimated blood loss was (243.0±49.6)minutes and (1 228±521)ml respectively in the free-hand group, which had no significant difference between the two groups. However, the implant density was higher in the O-arm group than that in the free-hand group ((64.1±10.8)% vs .(44.3±15.3)%)( t =4.652, P =0.000). The O-arm group comprised 122 screws, of which 72.9% were excellent, 22.1% were good and 4.9% were bad. The free-hand group comprised 136 screws and 48.5% of them were excellent, 33.8% were good and 17.6% were bad.Accuracy of pedicle screw insertion was higher in the O-arm group than that in the free-hand group(χ(2

  20. Side effects after diagnostic lumbar puncture and lumbar iohexol myelography

    International Nuclear Information System (INIS)

    Sand, T.; Stovner, L.J.; Salvesen, R.; Dale, L.

    1987-01-01

    A prospective, controlled study was performed to compare side effect incidences after lumbar iohexol myelography (n=97) and diagnostic lumbar puncture (n=85). No significant side effect incidence differences (iohexol vs. controls) were found regarding number of patients with any side effect (63 vs. 73%), headache (44 vs. 54%), nausea, dizziness, visual, auditory, or psychic symptoms. Early-onset headache occurred significantly more often in the iohexol group (16 vs 5%), while postural headache occurred most frequently after lumbar puncture (25 vs. 41%). These results suggest that apart from the slight early-onset headache, most side effets after lumbar iohexol myelography are related to the puncture per se, not to the contrast agent. (orig.)

  1. Screw piles for cold climate foundations

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.; Sakr, M. [Almita Manufacturing Ltd., Edmonton, AB (Canada)

    2008-07-01

    Almita Manufacturing is an Alberta-based company that designs and builds screw piles with its own installation teams. It also engineers and supplies piles to numerous other companies and independent installers. The company services industries such as oil and gas; power transmission and distribution; and commercial construction. This presentation discussed the design and technical aspects of screw piles. A screw pile was defined as a steel pipe shaft with a 45 degree cut at the bottom and a formed helical plate welded to the outside of the pipe near the base and at a selected point on the shaft. The pile is screwed into the ground with a planetary drive head of suitable torque rating. The helical plate or helix helps facilitate the installation of the pile and gives the screw pile increased bearing capacity and pull-out resistance over a traditional straight-shaft pile. Screw piles were compared against cast in place concrete piles and steel driven piles. Screw piles were reported to have no tailings; no concrete curing time; no rebar, anchor belts, and no liners; and no dewatering. Screw piles can also be installed in all types of weather. Rhe Cree Burn Camp case study near Fort McMurray, Alberta was also presented. This residential camp and recreation complex consists of pre-fabricated units that make up three storey housing buildings and a single floor multi-use building. The case study provided information on soil; design parameter inputs; load testing program and pile configuration; geotechnical and structural design results; compression load test arrangement; pile test setup; and test results. The presentation also discussed fabrication as well as installation equipment. Various applications were also presented through a series of project pictures. Last, the presentation provided a simple cost analysis. tabs., figs.

  2. Influence of Lumbar Lordosis on the Outcome of Decompression Surgery for Lumbar Canal Stenosis.

    Science.gov (United States)

    Chang, Han Soo

    2018-01-01

    Although sagittal spinal balance plays an important role in spinal deformity surgery, its role in decompression surgery for lumbar canal stenosis is not well understood. To investigate the hypothesis that sagittal spinal balance also plays a role in decompression surgery for lumbar canal stenosis, a prospective cohort study analyzing the correlation between preoperative lumbar lordosis and outcome was performed. A cohort of 85 consecutive patients who underwent decompression for lumbar canal stenosis during the period 2007-2011 was analyzed. Standing lumbar x-rays and 36-item short form health survey questionnaires were obtained before and up to 2 years after surgery. Correlations between lumbar lordosis and 2 parameters of the 36-item short form health survey (average physical score and bodily pain score) were statistically analyzed using linear mixed effects models. There was a significant correlation between preoperative lumbar lordosis and the 2 outcome parameters at postoperative, 6-month, 1-year, and 2-year time points. A 10° increase of lumbar lordosis was associated with a 5-point improvement in average physical scores. This correlation was not present in preoperative scores. This study showed that preoperative lumbar lordosis significantly influences the outcome of decompression surgery on lumbar canal stenosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Clinical anatomy and 3D virtual reconstruction of the lumbar plexus with respect to lumbar surgery

    Directory of Open Access Journals (Sweden)

    Ding Zi-hai

    2011-04-01

    Full Text Available Abstract Background Exposure of the anterior or lateral lumbar via the retroperitoneal approach easily causes injuries to the lumbar plexus. Lumbar plexus injuries which occur during anterior or transpsoas lumbar spine exposure and placement of instruments have been reported. This study aims is to provide more anatomical data and surgical landmarks in operations concerning the lumbar plexus in order to prevent lumbar plexus injuries and to increase the possibility of safety in anterior approach lumbar surgery. Methods To study the applied anatomy related to the lumbar plexus of fifteen formaldehyde-preserved cadavers, Five sets of Virtual Human (VH data set were prepared and used in the study. Three-dimensional (3D computerized reconstructions of the lumbar plexus and their adjacent structures were conducted from the VH female data set. Results The order of lumbar nerves is regular. From the anterior view, lumbar plexus nerves are arranged from medial at L5 to lateral at L2. From the lateral view, lumbar nerves are arranged from ventral at L2 to dorsal at L5. The angle of each nerve root exiting outward to the corresponding intervertebral foramen increases from L1 to L5. The lumbar plexus nerves are observed to be in close contact with transverse processes (TP. All parts of the lumbar plexus were located by sectional anatomy in the dorsal third of the psoas muscle. Thus, access to the psoas major muscle at the ventral 2/3 region can safely prevent nerve injuries. 3D reconstruction of the lumbar plexus based on VCH data can clearly show the relationships between the lumbar plexus and the blood vessels, vertebral body, kidney, and psoas muscle. Conclusion The psoas muscle can be considered as a surgical landmark since incision at the ventral 2/3 of the region can prevent lumbar plexus injuries for procedures requiring exposure of the lateral anterior of the lumbar. The transverse process can be considered as a landmark and reference in surgical

  4. Clinical anatomy and 3D virtual reconstruction of the lumbar plexus with respect to lumbar surgery.

    Science.gov (United States)

    Lu, Sheng; Chang, Shan; Zhang, Yuan-zhi; Ding, Zi-hai; Xu, Xin Ming; Xu, Yong-qing

    2011-04-14

    Exposure of the anterior or lateral lumbar via the retroperitoneal approach easily causes injuries to the lumbar plexus. Lumbar plexus injuries which occur during anterior or transpsoas lumbar spine exposure and placement of instruments have been reported. This study aims is to provide more anatomical data and surgical landmarks in operations concerning the lumbar plexus in order to prevent lumbar plexus injuries and to increase the possibility of safety in anterior approach lumbar surgery. To study the applied anatomy related to the lumbar plexus of fifteen formaldehyde-preserved cadavers, Five sets of Virtual Human (VH) data set were prepared and used in the study. Three-dimensional (3D) computerized reconstructions of the lumbar plexus and their adjacent structures were conducted from the VH female data set. The order of lumbar nerves is regular. From the anterior view, lumbar plexus nerves are arranged from medial at L5 to lateral at L2. From the lateral view, lumbar nerves are arranged from ventral at L2 to dorsal at L5. The angle of each nerve root exiting outward to the corresponding intervertebral foramen increases from L1 to L5. The lumbar plexus nerves are observed to be in close contact with transverse processes (TP). All parts of the lumbar plexus were located by sectional anatomy in the dorsal third of the psoas muscle. Thus, access to the psoas major muscle at the ventral 2/3 region can safely prevent nerve injuries. 3D reconstruction of the lumbar plexus based on VCH data can clearly show the relationships between the lumbar plexus and the blood vessels, vertebral body, kidney, and psoas muscle. The psoas muscle can be considered as a surgical landmark since incision at the ventral 2/3 of the region can prevent lumbar plexus injuries for procedures requiring exposure of the lateral anterior of the lumbar. The transverse process can be considered as a landmark and reference in surgical operations by its relative position to the lumbar plexus. 3D

  5. Complications of syndesmotic screw removal

    NARCIS (Netherlands)

    T. Schepers (Tim); E.M.M. van Lieshout (Esther); M.R. de Vries (Mark); M. van der Elst (Maarten)

    2011-01-01

    textabstractBackground: Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of

  6. Surgical Outcome of Reduction and Instrumented Fusion in Lumbar Degenerative Spondylolisthesis

    Directory of Open Access Journals (Sweden)

    Farzad Omidi-Kashani

    2016-02-01

    Full Text Available Background: Lumbar degenerative spondylolisthesis (LDS is a degenerative slippage of the lumbar vertebrae. We aimed to evaluate the surgical outcome of degenerative spondylolisthesis with neural decompression, pedicular screw fixation, reduction, and posterolateral fusion. Methods: This before-after study was carried out on 45 patients (37 female and 8 male with LDS operated from August 2008 to January 2011. The patients’ pain and disability were assessed by visual analogue scale (VAS and Oswestry disability index (ODI questionnaire. In surgery, we applied distraction force to facilitate slip reduction. All the intra- and postoperative complications were recorded. The paired t-test and Pearson correlation coefficient were used for statistical analysis. Results: The mean age of patients and mean follow-up period were 58.3±3.5 years and 31.2±4.8 months, respectively. The mean slip correction rate was 52.2% with a mean correction loss of 4.8%. Preoperative VAS and ODI improved from 8.8 and 71.6 to postoperative 2.1 and 28.7, respectively. Clinical improvement was more prominent in more reduced patients, but Pearson coefficient could not find a significant correlation. Conclusion: Although spinal decompression with fusion and posterior instrumentation in surgical treatment of the patients with LDS result in satisfactory outcome, vertebral reduction cannot significantly enhance the clinical improvement.

  7. Lumbar facet syndrome - Lumbar facet joint injection and low back pain

    International Nuclear Information System (INIS)

    Acevedo Gonzalez, Juan Carlos; Jimenez Hakim, Enrique; Rodriguez, Jose Maria; Hakim Daccach, Fernando; Quinonez, German; Rodriguez Munera, Andres

    2004-01-01

    The authors conducted a retrospective study lo evaluate the effectiveness of injection therapy in the lumbar zygapophysial joints with anesthetics and steroids in patients with persisting low back pain and lumbar facer syndrome. Thirty-seven patients with low back pain who reported immediate relief of their pain after controlled blocks into the facet joints between the fourth and fifth lumbar vertebrae and the fifth lumbar and first sacral vertebrae were evaluated. Outcome was evaluated using the visual analog pain scales. All outcome measures were repeated at eight days and six weeks alter controlled injection. At six-week follow-up examination 83,7% of thirty-seven patients experienced a good response to controlled blocks of the lumbar zygaphyseal (facet) joints. Good result is the pain relief of 50% or more. Fifteen patients experienced a good response with pain relief of eight points or more in the VAS

  8. Biomechanical evaluation of a corporectomy in porcine lumbar specimens using flexible polymer belts

    Science.gov (United States)

    Beltrán-Fernández, J. A.; Hernández-Gómez, L. H.; Ruiz-Muñoz, E.; González-Rebattú, A.; Rodríguez-Cañizo, R. G.; Urriolagoitia-Calderón, G.; Urriolagoitia-Sosa, G.; Hernández-Moreno, H.

    2009-08-01

    This paper presents the experimental results of a biomechanical evaluation in lumbar porcine specimens (L2-L4), instrumented with flexible polymer belts, under fatigue and tensile loading. The clinical effect called facetary arthrosis is evaluated. An experimental analysis was carried on 3 lumbar porcine specimens. In two of them, polyamide belts are fixed on the interspinous ligament from L2 to L4. Specimens are taken from pigs which are 6 month old. For the present work, the stiffness reduction of the spine and the biomechanical behaviour of the belts in conjunction with the interspinous ligament are evaluated. The purpose is to determine the failure conditions for the elements of the specimen (vertebral disk, supra and intraspinous ligament and vertebral body). Under static loading, which is the base line case, the elements of the specimen failed as a typical healthy structure. While in the fatigue combined with static loading, the element failed in different order. Additionally, the stiffness changed in accordance with the fatigue loading conditions. Because of the simplicity of this alternative technique, a high level of the structural integrity is preserved, as no holes are made on the spinous process in order to insert the fixation screws. Furthermore, there is a cost reduction.

  9. Biomechanical evaluation of a corporectomy in porcine lumbar specimens using flexible polymer belts

    International Nuclear Information System (INIS)

    Beltran-Fernandez, J A; Hernandez-Gomez, L H; Ruiz-Munoz, E; Urriolagoitia-Calderon, G; Urriolagoitia-Sosa, G; Gonzalez-Rebattu, A; RodrIguez-Canizo, R G; Hernandez-Moreno, H

    2009-01-01

    This paper presents the experimental results of a biomechanical evaluation in lumbar porcine specimens (L2-L4), instrumented with flexible polymer belts, under fatigue and tensile loading. The clinical effect called facetary arthrosis is evaluated. An experimental analysis was carried on 3 lumbar porcine specimens. In two of them, polyamide belts are fixed on the interspinous ligament from L2 to L4. Specimens are taken from pigs which are 6 month old. For the present work, the stiffness reduction of the spine and the biomechanical behaviour of the belts in conjunction with the interspinous ligament are evaluated. The purpose is to determine the failure conditions for the elements of the specimen (vertebral disk, supra and intraspinous ligament and vertebral body). Under static loading, which is the base line case, the elements of the specimen failed as a typical healthy structure. While in the fatigue combined with static loading, the element failed in different order. Additionally, the stiffness changed in accordance with the fatigue loading conditions. Because of the simplicity of this alternative technique, a high level of the structural integrity is preserved, as no holes are made on the spinous process in order to insert the fixation screws. Furthermore, there is a cost reduction.

  10. Lower complication and reoperation rates for laminectomy rather than MI TLIF/other fusions for degenerative lumbar disease/spondylolisthesis: A review

    Science.gov (United States)

    Epstein, Nancy E.

    2018-01-01

    Background: Utilizing the spine literature, we compared the complication and reoperation rates for laminectomy alone vs. instrumented fusions including minimally invasive (MI) transforaminal lumbar interbody fusion (TLIF) for the surgical management of multilevel degenerative lumbar disease with/without degenerative spondylolisthesis (DS). Methods: Epstein compared complication and reoperation rates over 2 years for 137 patients undergoing laminectomy alone undergoing 2-3 level (58 patients) and 4-6 level (79 patients) Procedures for lumbar stenosis with/without DS. Results showed no new postoperative neurological deficits, no infections, no surgery for adjacent segment disease (ASD), 4 patients (2.9%) who developed intraoperative cerebrospinal fluid (CSF) fistulas, no readmissions, and just 1 reopereation for a (postoperative day 7). These rates were compared to other literature for lumbar laminectomies vs. fusions (e.g. particularly MI TLIF) addressing pathology comparable to that listed above. Results: Some studies in the literature revealed an average 4.8% complication rate for laminectomy alone vs. 8.3% for decompressions/fusion; at 5 postoperative years, reoperation rates were 10.6% vs. 18.4%, respectively. Specifically, the MI TLIF literature complication rates ranged from 7.7% to 23.0% and included up to an 8.3% incidence of wound infections, 6.1% durotomies, 9.7% permanent neurological deficits, and 20.2% incidence of new sensory deficits. Reoperation rates (1.6–6%) for MI TLIF addressed instrumentation failure (2.3%), cage migration (1.26–2.4%), cage extrusions (0.8%), and misplaced screws (1.6%). The learning curve (e.g. number of cases required by a surgeon to become proficient) for MI TLIF was the first 33-44 cases. Furthermore, hospital costs for lumbar fusions were 2.6 fold greater than those for laminectomy alone, with overall neurosurgeon reimbursement quoted in one study as high as $142,075 per year. Conclusions: The spinal literature revealed

  11. Dual-worm screw compressors; Compresseurs bi-vis

    Energy Technology Data Exchange (ETDEWEB)

    Baleydier, J P [Bitzer France, 69 - Lyon (France)

    1998-12-31

    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  12. Dual-worm screw compressors; Compresseurs bi-vis

    Energy Technology Data Exchange (ETDEWEB)

    Baleydier, J.P. [Bitzer France, 69 - Lyon (France)

    1997-12-31

    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  13. reduction mammoplasty using inferior pedicle in heavy breasts

    African Journals Online (AJOL)

    2011-09-09

    Sep 9, 2011 ... sexual relationships. Reduction mammoplasty procedure provides weight and volume reduction of the breast as well as enhancement of the aesthetic appearance of the breasts. In this study, the inferior pedicle technique was used in reduction of thirty five patients over the last four years with macromastia.

  14. Vertical-Screw-Auger Conveyer Feeder

    Science.gov (United States)

    Walton, Otis (Inventor); Vollmer, Hubert J. (Inventor)

    2016-01-01

    A conical feeder is attached to a vertically conveying screw auger. The feeder is equipped with scoops and rotated from the surface to force-feed regolith the auger. Additional scoops are possible by adding a cylindrical section above the conical funnel section. Such then allows the unit to collect material from swaths larger in diameter than the enclosing casing pipe of the screw auger. A third element includes a flexible screw auger. All three can be used in combination in microgravity and zero atmosphere environments to drill and recover a wide area of subsurface regolith and entrained volatiles through a single access point on the surface.

  15. Osseous anatomy of the lumbosacral spine in Marfan syndrome.

    Science.gov (United States)

    Sponseller, P D; Ahn, N U; Ahn, U M; Nallamshetty, L; Rose, P S; Kuszyk, B S; Fishman, E K

    2000-11-01

    This study examines pedicle widths, laminar thicknesses, and scalloping values for lumbosacral spine elements in Marfan volunteers. Comparisons were made between these measurements and norms as well as measurements between Marfan patients with and without dural ectasia. To determine if the lumbosacral vertebral elements are altered in the patient with Marfan syndrome. Several abnormalities have been noted in Marfan lumbar spine, including pedicular attenuation and widened interpediculate distances. This may be due to abnormalities of growth or presence of dural ectasia. Given the large numbers of Marfan patients requiring spinal surgery and the high postoperative failure rate, better understanding of the bony anatomy of Marfan lumbar spine is necessary, especially if use of instrumentation is anticipated. Thirty-two volunteers with Marfan syndrome based on the Ghent criteria underwent spiral computed tomography of the lumbosacral spine. Images were evaluated for dural ectasia, and measurements of pedicle width, laminar thickness, and vertebral scalloping were made. Pedicle widths and laminar thicknesses were significantly smaller in Marfan patients at all levels (Plaminar thickness from L5-S2 and pedicle widths at all lumbar levels were significantly reduced (Plaminar thickness are significantly reduced in Marfan individuals. Those with dural ectasia demonstrate increased bony erosion of anterior and posterior elements of lumbosacral spine. Preoperative planning and routine computed tomography scans are recommended when operating on Marfan lumbosacral spine.

  16. [Pedicled versus free TRAM flap for breast reconstruction].

    Science.gov (United States)

    Galla, T J; Lukas, B; Feller, A M

    1999-03-01

    In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.

  17. Short-Term Therapeutic Efficacy of the Isobar TTL Dynamic Internal Fixation System for the Treatment of Lumbar Degenerative Disc Diseases.

    Science.gov (United States)

    Qian, Jiale; Bao, Zhaohua; Li, Xuefeng; Zou, Jun; Yang, Huilin

    2016-07-01

    At present, posterior interbody fusion surgery with pedicle internal fixation is the gold standard for the treatment of lumbar degenerative disc diseases. However, an increasing number of studies have shown that because fused lumbar vertebrae lose their physiological activity, the compensatory range of motion (ROM) of the adjacent levels increases. To address this issue, dynamic internal fixation systems have been developed. Our goal was to investigate the short-term therapeutic efficacy of the Isobar TTL dynamic internal fixation system for the treatment of lumbar degenerative disc diseases and its effect on the ROM of the surgical segments. Retrospective Evaluation. Tertiary hospital setting in China. Twenty-four lumbar degenerative disc disease patients who underwent posterior lumbar decompression and single-segment Isobar TTL dynamic internal fixation at our hospital between January 2013 and July 2014 were retrospectively analyzed. The preoperative and one month, 3 month, and 12 month postoperative visual analog scale (VAS) pain scores, Japanese Orthopedic Association (JOA) scores, and Oswestry Disability Index (ODI) scores were observed and recorded to assess the clinical therapeutic effect; the lumbar ROM was measured preoperatively and at the last follow-up to evaluate the preservation of functional movement in the dynamically stabilized segment. All patients underwent the operation successfully without complications during hospitalization and were followed for 12 to 27 months, with an average of 18 months. The patients' preoperative and one month, 3 month, and 12 month postoperative VAS scores were 6.42 ± 0.72, 1.71 ± 0.86, 1.38 ± 0.65, and 1.37 ± 0.58, respectively, and their JOA scores were 9.54 ± 1.89, 21.21 ± 1.98, 22.50 ± 1.47, and 23.46 ± 1.32, respectively. The preoperative ODI score was 42.04 ± 2.63; the one month, 3 month, and 12 month postoperative ODI scores were 22.79 ± 1.61, 18.63 ± 1.61, and 15.08 ± 1.21, respectively. These

  18. Minimally-invasive posterior lumbar stabilization for degenerative low back pain and sciatica. A review

    Energy Technology Data Exchange (ETDEWEB)

    Bonaldi, G., E-mail: bbonaldi@yahoo.com [Neuroradiology Department, Ospedale Papa Giovanni XXIII, Bergamo (Italy); Brembilla, C. [Department of neurosurgery, Ospedale Papa Giovanni XXIII, Bergamo (Italy); Cianfoni, A. [Neuroradiology of Neurocenter of Italian Switzerland, Lugano, CH (Switzerland)

    2015-05-15

    The most diffused surgical techniques for stabilization of the painful degenerated and instable lumbar spine, represented by transpedicular screws and rods instrumentation with or without interbody cages or disk replacements, require widely open and/or difficult and poorly anatomical accesses. However, such surgical techniques and approaches, although still considered “standard of care”, are burdened by high costs, long recovery times and several potential complications. Hence the effort to open new minimally-invasive surgical approaches to eliminate painful abnormal motion. The surgical and radiological communities are exploring, since more than a decade, alternative, minimally-invasive or even percutaneous techniques to fuse and lock an instable lumbar segment. Another promising line of research is represented by the so-called dynamic stabilization (non-fusion or motion preservation back surgery), which aims to provide stabilization to the lumbar spinal units (SUs), while maintaining their mobility and function. Risk of potential complications of traditional fusion methods (infection, CSF leaks, harvest site pain, instrumentation failure) are reduced, particularly transitional disease (i.e., the biomechanical stresses imposed on the adjacent segments, resulting in delayed degenerative changes in adjacent facet joints and discs). Dynamic stabilization modifies the distribution of loads within the SU, moving them away from sensitive (painful) areas of the SU. Basic biomechanics of the SU will be discussed, to clarify the mode of action of the different posterior stabilization devices. Most devices are minimally invasive or percutaneous, thus accessible to radiologists’ interventional practice. Devices will be described, together with indications for patient selection, surgical approaches and possible complications.

  19. Minimally-invasive posterior lumbar stabilization for degenerative low back pain and sciatica. A review

    International Nuclear Information System (INIS)

    Bonaldi, G.; Brembilla, C.; Cianfoni, A.

    2015-01-01

    The most diffused surgical techniques for stabilization of the painful degenerated and instable lumbar spine, represented by transpedicular screws and rods instrumentation with or without interbody cages or disk replacements, require widely open and/or difficult and poorly anatomical accesses. However, such surgical techniques and approaches, although still considered “standard of care”, are burdened by high costs, long recovery times and several potential complications. Hence the effort to open new minimally-invasive surgical approaches to eliminate painful abnormal motion. The surgical and radiological communities are exploring, since more than a decade, alternative, minimally-invasive or even percutaneous techniques to fuse and lock an instable lumbar segment. Another promising line of research is represented by the so-called dynamic stabilization (non-fusion or motion preservation back surgery), which aims to provide stabilization to the lumbar spinal units (SUs), while maintaining their mobility and function. Risk of potential complications of traditional fusion methods (infection, CSF leaks, harvest site pain, instrumentation failure) are reduced, particularly transitional disease (i.e., the biomechanical stresses imposed on the adjacent segments, resulting in delayed degenerative changes in adjacent facet joints and discs). Dynamic stabilization modifies the distribution of loads within the SU, moving them away from sensitive (painful) areas of the SU. Basic biomechanics of the SU will be discussed, to clarify the mode of action of the different posterior stabilization devices. Most devices are minimally invasive or percutaneous, thus accessible to radiologists’ interventional practice. Devices will be described, together with indications for patient selection, surgical approaches and possible complications

  20. Biomechanical study of percutaneous lumbar diskectomy

    International Nuclear Information System (INIS)

    Li Yuan; Huang Xianglong; Shen Tianzhen; Hu Zhou; Hong Shuizong; Mei Haiying

    2003-01-01

    Objective: To investigate the stiffness of lumbar spine after the injury caused by percutaneous diskectomy and evaluate the efficiency of percutaneous lumbar diskectomy by biomechanical study. Methods: Four fresh lumbar specimens were used to analyse load-displacement curves in the intact lumbar spine and vertical disc-injured lumbar spine. The concepts of average flexibility coefficient (f) and standardized average flexibility coefficient (fs) were also introduced. Results: The load-displacement curves showed a good stabilization effect of the intact lumbar spine and disc-injured lumbar spine in flexion, extension, right and left bending. The decrease of anti-rotation also can be detected (P<0.05). Conclusion: In biomechanical study, percutaneous lumbar diskectomy is one of the efficiency methods to treat lumbar diac hernia

  1. Calculating Characteristics of the Screws with Constant And Variable Step

    Directory of Open Access Journals (Sweden)

    B. N. Zotov

    2015-01-01

    Full Text Available This work is devoted to creating a technique for calculating power characteristics of the screws with constant and variable step for the centrifugal pumps. The technique feature is that the reverse currents, which are observed in screws working at low flow, are numerically taken into account. The paper presents a diagram of the stream in the screw with flow to the network Q=0, and the static pressure of the screw in this mode is computed according to reverse current parameters. Maximum flow of screw is determined from the known formulas. When calculating the power characteristics and computing the overall efficiency of the screw, for the first time a volumetric efficiency of the screw is introduced. It is defined as a ratio between the flow into the network and the sum of the reverse current flows and a flow into the network. This approach allowed us to determine the efficiency of the screw over the entire range of flows.A comparison of experimental characteristics of the constant step screw with those of calculated by the proposed technique shows their good agreement.The technique is also used in calculating characteristics of the variable step screws. The variable step screw is considered as a screw consisting of two screws with a smooth transition of the blades from the inlet to the outlet. Screws in which the step at the inlet is less than that of at the outlet as well as screws with the step at the inlet being more than that of at the outlet were investigated. It is shown that a pressure of the screw with zero step and the value of the reverse currents depend only on the parameters of the input section of the screw, and the maximum flow, if the step at the inlet is more than the step at the outlet, is determined by the parameters of the output part of the screw. Otherwise, the maximum flow is determined a little bit differently.The paper compares experimental characteristics with characteristics calculated by the technique for variable step

  2. Sagittal Plane Correction Using the Lateral Transpsoas Approach: A Biomechanical Study on the Effect of Cage Angle and Surgical Technique on Segmental Lordosis.

    Science.gov (United States)

    Melikian, Rojeh; Yoon, Sangwook Tim; Kim, Jin Young; Park, Kun Young; Yoon, Caroline; Hutton, William

    2016-09-01

    Cadaveric biomechanical study. To determine the degree of segmental correction that can be achieved through lateral transpsoas approach by varying cage angle and adding anterior longitudinal ligament (ALL) release and posterior element resection. Lordotic cage insertion through the lateral transpsoas approach is being used increasingly for restoration of sagittal alignment. However, the degree of correction achieved by varying cage angle and ALL release and posterior element resection is not well defined. Thirteen lumbar motion segments between L1 and L5 were dissected into single motion segments. Segmental angles and disk heights were measured under both 50 N and 500 N compressive loads under the following conditions: intact specimen, discectomy (collapsed disk simulation), insertion of parallel cage, 10° cage, 30° cage with ALL release, 30° cage with ALL release and spinous process (SP) resection, 30° cage with ALL release, SP resection, facetectomy, and compression with pedicle screws. Segmental lordosis was not increased by either parallel or 10° cages as compared with intact disks, and contributed small amounts of lordosis when compared with the collapsed disk condition. Placement of 30° cages with ALL release increased segmental lordosis by 10.5°. Adding SP resection increased lordosis to 12.4°. Facetectomy and compression with pedicle screws further increased lordosis to approximately 26°. No interventions resulted in a decrease in either anterior or posterior disk height. Insertion of a parallel or 10° cage has little effect on lordosis. A 30° cage insertion with ALL release resulted in a modest increase in lordosis (10.5°). The addition of SP resection and facetectomy was needed to obtain a larger amount of correction (26°). None of the cages, including the 30° lordotic cage, caused a decrease in posterior disk height suggesting hyperlordotic cages do not cause foraminal stenosis. N/A.

  3. scrotal reconstruction with a pedicled gracilis muscle flap after

    African Journals Online (AJOL)

    nonviable tissue is removed and a granulation bed suitable for .... The pedicled or free greater omental flap as well as scrotal tissue ... Bien-keem Tan, Mohammed ZulfikarRasheed,. WofflesT.L.Wu ... Honda Hsu Chih Ming Lin, Tzong-Bon Sun,.

  4. Evaluation of 99mTc-MDP bone imaging in monitoring the muscle-pedicle bone graft osteogenic activation

    International Nuclear Information System (INIS)

    Sang Shibiao; Wu Yiwei; Zhang Wei; Jiang Yimin; Chen Guangxiang; Dong Tianhua

    2002-01-01

    Nine mature and healthy dogs were divided into 4 groups randomly. The first group consists of 3 dogs, and the rest groups, 2 dogs. Self-control way was used. The left ilium was the experimental site, where the bone piece with sartorial muscle attached was cut from ilium. The right side served as control, where the graft bone from ilium was wrapped up with silica gel, then fixed subcutaneously. The pedicled bone pieces were retrieved in 2, 4, 6, 8 weeks after surgery, the size of graft bones from two sides were the same. Survival range, osteogenic formation of muscle-pedicle bone were examined by 99m Tc-MDP bone imaging and histological method to evaluate the clinical value of treatment of ischemic osteonecrosis of the femoral head with muscle-pedicle bone grafting. The results were as follows: 1. The part of bone attached by the sartorial survived, but osteonecrosis was observed at the location of 1.2-1.7 cm from attached point of muscle. 2. There were two forms observed in the course of osteogenic activation of muscle-pedicle bone. Under the reduction of mechanical stimulation and blood supply, bone marrow tissue was replaced by fibro-granulation tissue and new capillary in the survival part, while the survival bone of proximal part grew distally and gradually replace the dead bone of distal part. 3. Histological examination revealed that small amounts of fibro-granulation tissue and new capillary appeared in 2nd week, primary trabeculae appeared in 6th week, and in 8th week, some trabeculae recovered their normal appearance and osteogenic cell reduced remarkably. 4. Survival range of muscle-pedicle graft bone was directly proportional to the width of muscle pedicle. Therefore, radionuclide bone imaging and histological examination demonstrated that muscle-pedicle graft bone was a piece of bone with relatively poor blood supply, its effect is repairing necrosis and collapse of the femoral head is limited. 99m Tc-MDP bone imaging may be an effective and first

  5. [Biomechanics changes of lumbar spine caused by foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy].

    Science.gov (United States)

    Qian, J; Yu, S S; Liu, J J; Chen, L; Jing, J H

    2018-04-03

    Objective: To analyze the biomechanics changes of lumbar spine caused by foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy using the finite element method. Methods: Three healthy adult males (aged 35.6 to 42.3 years) without spinal diseases were enrolled in this study and 3D-CT scans were carried out to obtain the parameters of lumbar spine. Mimics software was applied to build a 3D finite element model of lumbar spine. Graded resections (1/4, 2/4, 3/4 and 4/4) of the left superior articular process of L(5) were done via percutaneous transforaminal endoscopic lumbar discectomy. Then, the pressure of the L(4/5) right facets, the pressure of the L(4/5) intervertebral disc and the motion of lumbar spine were recorded after simulating the normal flexion and extension, lateral flexion and rotation of the lumbar spine model during different resections. The data were compared among groups with analysis of variance. Results: Comparing with the normal group, after 1/4 resection of the left superior articular process of L(5), the pressure of the L(4/5) right facets showed significant differences during left lateral flexion and rotation of lumbar spine ( q =8.823, 8.248, both P biomechanics and the stability of lumbar spine changed partly after 1/4 resection of the superior articular process and obviously after more than 2/4 is resected. The superior articular process should be paid more attention during foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy.

  6. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  7. Head and neck reconstruction with pedicled flaps in the free flap era.

    Science.gov (United States)

    Mahieu, R; Colletti, G; Bonomo, P; Parrinello, G; Iavarone, A; Dolivet, G; Livi, L; Deganello, A

    2016-12-01

    Nowadays, the transposition of microvascular free flaps is the most popular method for management of head and neck defects. However, not all patients are suitable candidates for free flap reconstruction. In addition, not every defect requires a free flap transfer to achieve good functional results. The aim of this study was to assess whether pedicled flap reconstruction of head and neck defects is inferior to microvascular free flap reconstruction in terms of complications, functionality and prognosis. The records of consecutive patients who underwent free flap or pedicled flap reconstruction after head and neck cancer ablation from 2006 to 2015, from a single surgeon, in the AOUC Hospital, Florence Italy were analysed. A total of 93 patients, the majority with oral cancer (n = 59), were included, of which 64 were pedicled flap reconstructions (69%). The results showed no significant differences in terms of functional outcome, flap necrosis and complications in each type of reconstruction. Multivariate regression analysis of flap necrosis and functional impairments showed no associated factors. Multivariate regression analysis of complicated flap healing showed that only comorbidities remained an explaining factor (p = 0.019). Survival analysis and proportional hazard regression analysis regarding cancer relapse or distant metastasis, showed no significant differences in prognosis of patients concerning both types of reconstruction. In this retrospective, non-randomised study cohort, pedicled flaps were not significantly inferior to free flaps for reconstruction of head and neck defects, considering functionality, complications and prognosis. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  8. Use of omental pedicle flap for radiation induced chest wall ulcer. A case report

    International Nuclear Information System (INIS)

    Takamori, Shinzo; Hayashi, Akihiro; Nagamatsu, Yoshinori; Tsushimi, Mutsuo; Ono, Hirofumi; Ohtsuka, Shoji

    1995-01-01

    A 79-year-old female with breast carcinoma undergoing a classical Halsted radical mastectomy followed by irradiation (total; 180 Gy) 20 years before developed a left anterior chest wall ulcer. The ulcer was 10.0 x 8.0 cm in size with osteolysis of 3rd, 4th and 5th ribs, exposed pericardium, and parietal pleura with a pleuro-cutaneous fistula. After thorough debridement, an omental pedicle flap was transposed onto the chest wall defect and subsequently covered using a split-skin graft. The omental pedicle flap was 90% effective in covering the pericardial defect and resulted in a complete closure of the pleuro-cutaneous fistula. This report emphasises that an omental pedicle flap is effective in the treatment of radio-necrosis of the chest wall and also stresses the importance of judging the extent of debridement of radio-necrotic tissue. (author)

  9. Use of omental pedicle flap for radiation induced chest wall ulcer. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Takamori, Shinzo; Hayashi, Akihiro; Nagamatsu, Yoshinori; Tsushimi, Mutsuo; Ono, Hirofumi; Ohtsuka, Shoji [Kurume Univ., Fukuoka (Japan). School of Medicine

    1995-12-01

    A 79-year-old female with breast carcinoma undergoing a classical Halsted radical mastectomy followed by irradiation (total; 180 Gy) 20 years before developed a left anterior chest wall ulcer. The ulcer was 10.0 x 8.0 cm in size with osteolysis of 3rd, 4th and 5th ribs, exposed pericardium, and parietal pleura with a pleuro-cutaneous fistula. After thorough debridement, an omental pedicle flap was transposed onto the chest wall defect and subsequently covered using a split-skin graft. The omental pedicle flap was 90% effective in covering the pericardial defect and resulted in a complete closure of the pleuro-cutaneous fistula. This report emphasises that an omental pedicle flap is effective in the treatment of radio-necrosis of the chest wall and also stresses the importance of judging the extent of debridement of radio-necrotic tissue. (author).

  10. Ball Screw Actuator Including a Stop with an Integral Guide

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  11. Ball Screw Actuator Including an Axial Soft Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)

    2016-01-01

    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  12. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    Science.gov (United States)

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Tratamento cirúrgico da escoliose em pacientes com amiotrofia espinhal com parafusos pediculares (instrumental de 3ª geração e complicações precoces Tratamiento quirúrgico de la escoliosis en pacientes con amiotrofia espinal con tornillos pediculares (instrumental de 3ª generación y complicaciones precoces Surgical treatment of scoliosis in spinal muscular atrophy with pedicle screws (third generation instrumentation and early complications

    Directory of Open Access Journals (Sweden)

    Daniel Cantarelli dos Santos

    2010-06-01

    pacientes tuvieron complicaciones precoces (31.2% con buena resolución. CONCLUSIÓN: el tratamiento quirúrgico de la escoliosis en pacientes con amiotrofia espinal, con artrodesis vía posterior utilizando tornillos pediculares, tiene gran potencial de corrección de la deformidad coronal y de la oblicuidad pélvica, sin grandes complicaciones en el postoperatorio precoz.OBJECTIVES: to report the results on the treatment of scoliosis in spinal muscular atrophy, using posterior arthrodesis with pedicle screws. METHODS: a retrospective study was carried out with 16 patients who underwent posterior spinal fusion with pedicle screws. The general status of the patients, correction of the Cobb angle, correction of pelvic obliquity and early complications were analyzed. RESULTS: the initial Cobb angle mean was 94.6º (65 to 132º turning into 40,4º (2 to 20º after the surgery, correction of 57.2%. The initial pelvic obliquity mean was 34.7º(25 to 56º turning into 11.3º (0 to 20º, correction of 67.4%. CONCLUSIONS: the treatment of scoliosis in spinal muscular atrophy using posterior arthrodesis with pedicle screws presents a great potential of correction for the coronal deformity and pelvic obliquity, without serious early complications.

  14. [Finite element analysis of lumbar pelvic and proximal femur model with simulate lumbar rotatory manipulation].

    Science.gov (United States)

    Hu, Hua; Xiong, Chang-Yuan; Han, Guo-Wu

    2012-07-01

    To study the changes of displacement and stress in the model of lumbar pelvic and proximal femur during lumbar rotatory manipulation. The date of lumbar pelvic and proximal femur CT scan by Mimics 10.01 software was established a lumbar pelvic and proximal femur geometric model, then the model was modified with Geomagic 9, at last the modified model was imported into hypermesh 10 and meshed with tetrahedron, at the same time,add disc and ligaments. According to the principle of lumbar rotatory manipulation,the lumbar rotatory manipulation were decomposed. The mechanical parameters assigned into the three-dimensional finite element model. The changes of displacement and stress in the model of lunbar pelvic and proximal femur under the four conditions were calculated with Abaqus model of Hypermesh 10. 1) Under the same condition,the displacement order of lumbar was L1>L2>L3>L5 L5, anterior column > middle column > posterior column. 2) Under the different conditions, the displacement order of lumbar,case 3>case 1>case 4>case 2. 3) Under the same conditions, the displacement order of lumbar inter-vertebral disc from L1,2 to L5S1 was L1,2>L2,3>L3,4>L4,5>L5S1, as for the same inter-vertebral disc, the order was: second quadrant>third quadrant>first quadrant>fourth quadrant. 4) Under the different conditions,the displacement order of the inter-vertebral disc was L1,2>L2,3>L3,4>L4,5>L5S1, but to same inter-vertebral disc: case 3>case 4>case 1 >case 2. 5) There were apparent displacement and stress concentration in pelvis and hip during the manipulation. 1) The principles of lumbar rotation manipulation closely related to the relative displacement caused by rotation of various parts of lumbar pelvic and proximal femur model; 2) During the process of lumbar rotatory manipulation, the angle of lateral bending and flexion can not be randomly increased; 3) During the process of lumbar rotatory manipulation, all the conditions of lumbar pelvic and proximal femur must be

  15. Hydraulic screw fastening devices - design, maintenance, operational experience

    International Nuclear Information System (INIS)

    Lachner.

    1976-01-01

    With hydraulic screw fastening devices, pretension values with a maximum deviation of +-2.5% from the rated value can be achieved. This high degree of pretension accuracy is of considerable importance with regard to the safety factor required for the screw connection between reactor vessel head and reactor vessel. The operating rhythm of a nuclear power station with its refuelling art regular intervals makes further demands on the screw fastening device, in particular in connection with the transport of screws and for nuts. The necessary installations extend the screw fastening device into a combination of a high-pressure hydraulic cylinder system with an electrical or pneumoelectrical driving unit and an electrical control unit. Maintenance work is complicated by the large number of identical, highly stressed structural elements in connection with an unfavourable relation operating time/outage time. The problems have been perpetually reduced by close cooperation between the manufacturers and users of screw fastening devices. (orig./AK) [de

  16. Stress corrosion cracking lifetime prediction of spring screw

    International Nuclear Information System (INIS)

    Koh, S. K.; Ryu, C. H.

    2004-01-01

    A lifetime prediction of holddown spring screw in nuclear fuel assembly was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure and to predict the stress corrosion cracking life of the screw, a stress analysis of the top nozzle spring assembly was done using finite element analysis. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Normalized stress intensity factors for PWSCC life prediction was proposed. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.78 years, which was fairly close to the actual service life of the holddown spring screw

  17. Lateral retroperitoneal transpsoas interbody fusion in a patient with achondroplastic dwarfism.

    Science.gov (United States)

    Staub, Blake N; Holman, Paul J

    2015-02-01

    The authors present the first reported use of the lateral retroperitoneal transpsoas approach for interbody arthrodesis in a patient with achondroplastic dwarfism. The inherent anatomical abnormalities of the spine present in achondroplastic dwarfism predispose these patients to an increased incidence of spinal deformity as well as neurogenic claudication and potential radicular symptoms. The risks associated with prolonged general anesthesia and intolerance of significant blood loss in these patients makes them ideal candidates for minimally invasive spinal surgery. The patient in this case was a 51-year-old man with achondroplastic dwarfism who had a history of progressive claudication and radicular pain despite previous extensive lumbar laminectomies. The lateral retroperitoneal transpsoas approach was used for placement of interbody cages at L1/2, L2/3, L3/4, and L4/5, followed by posterior decompression and pedicle screw instrumentation. The patient tolerated the procedure well with no complications. Postoperatively his claudicatory and radicular symptoms resolved and a CT scan revealed solid arthrodesis with no periimplant lucencies.

  18. Magnesium Alloys as a Biomaterial for Degradable Craniofacial Screws

    Science.gov (United States)

    Henderson, Sarah E.; Verdelis, Konstantinos; Maiti, Spandan; Pal, Siladitya; Chung, William L.; Chou, Da-Tren; Kumta, Prashant N.; Almarza, Alejandro J.

    2014-01-01

    Recently, magnesium (Mg) alloys have received significant attention as a potential biomaterial for degradable implants, and this study was directed at evaluating the suitability of Mg for craniofacial bone screws. The objective was to implant screws fabricated from commercially available Mg-alloys (pure Mg and AZ31) in-vivo in a rabbit mandible. First, Mg-alloy screws were compared to stainless steel screws in an in-vitro pull-out test and determined to have a similar holding strength (~40N). A finite element model of the screw was created using the pull-out test data, and the model can be used for future Mg-alloy screw design. Then, Mg-alloy screws were implanted for 4, 8, and 12 weeks, with two controls of an osteotomy site (hole) with no implant and a stainless steel screw implanted for 12 weeks. MicroCT (computed tomography) was used to assess bone remodeling and Mg-alloy degradation, both visually and qualitatively through volume fraction measurements for all time points. Histologic analysis was also completed for the Mg-alloys at 12 weeks. The results showed that craniofacial bone remodeling occurred around both Mg-alloy screw types. Pure Mg had a different degradation profile than AZ31, however bone growth occurred around both screw types. The degradation rate of both Mg-alloy screw types in the bone marrow space and the muscle were faster than in the cortical bone space at 12 weeks. Furthermore, it was shown that by alloying Mg, the degradation profile could be changed. These results indicate the promise of using Mg-alloys for craniofacial applications. PMID:24384125

  19. Etiology of lumbar lordosis and its pathophysiology: a review of the evolution of lumbar lordosis, and the mechanics and biology of lumbar degeneration.

    Science.gov (United States)

    Sparrey, Carolyn J; Bailey, Jeannie F; Safaee, Michael; Clark, Aaron J; Lafage, Virginie; Schwab, Frank; Smith, Justin S; Ames, Christopher P

    2014-05-01

    The goal of this review is to discuss the mechanisms of postural degeneration, particularly the loss of lumbar lordosis commonly observed in the elderly in the context of evolution, mechanical, and biological studies of the human spine and to synthesize recent research findings to clinical management of postural malalignment. Lumbar lordosis is unique to the human spine and is necessary to facilitate our upright posture. However, decreased lumbar lordosis and increased thoracic kyphosis are hallmarks of an aging human spinal column. The unique upright posture and lordotic lumbar curvature of the human spine suggest that an understanding of the evolution of the human spinal column, and the unique anatomical features that support lumbar lordosis may provide insight into spine health and degeneration. Considering evolution of the skeleton in isolation from other scientific studies provides a limited picture for clinicians. The evolution and development of human lumbar lordosis highlight the interdependence of pelvic structure and lumbar lordosis. Studies of fossils of human lineage demonstrate a convergence on the degree of lumbar lordosis and the number of lumbar vertebrae in modern Homo sapiens. Evolution and spine mechanics research show that lumbar lordosis is dictated by pelvic incidence, spinal musculature, vertebral wedging, and disc health. The evolution, mechanics, and biology research all point to the importance of spinal posture and flexibility in supporting optimal health. However, surgical management of postural deformity has focused on restoring posture at the expense of flexibility. It is possible that the need for complex and costly spinal fixation can be eliminated by developing tools for early identification of patients at risk for postural deformities through patient history (genetics, mechanics, and environmental exposure) and tracking postural changes over time.

  20. Congenitally absent thoracic pedicle in a child with rhabdomyosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Kaufman, R A; Poznanski, A K; Hensinger, R N

    1980-04-01

    A case of congenital absence of a thoracic pedicle is reported in a 9 year old boy with embryonal rhabdomyosarcoma of the eyelid. In this clinical setting a surgical exploration was necessary in order to differentiate a developmental anomaly from an acquired metastatic deposit.

  1. Post-traumatic arteriovenous fistula of the hepatic pedicle.

    Science.gov (United States)

    Ibn Majdoub Hassani, K; Mohsine, R; Belkouchi, A; Bensaid, Y

    2010-10-01

    Hepatico-portal fistula (HPF) is a rare condition, most often of post-traumatic or iatrogenic origin and occasionally secondary to a ruptured aneurysm of the hepatic artery into the portal vein. HPF in extrahepatic locations often results in portal hypertension (PHT). While Doppler ultrasound, CT angiography, and magnetic resonance angiography are usually demonstrative, arteriography remains indispensable to clarify the exact anatomical configuration. In the treatment of these arteriovenous (AV) fistulas, open surgical approaches have increasingly given way to radiological embolization techniques, especially in intrahepatic locations, but surgery remains indicated for AV fistulas of the hepatic pedicle where maintenance of hepatic arterial flow is a priority of treatment. We report a patient who had an AV fistula of the hepatic pedicle with resultant PHT presenting 5 years after open abdominal trauma. Treatment was surgical; the immediate and long-term postoperative course was uneventful with regression of PHT. Through analysis of this case and a review of the literature, we discuss the clinical, paraclinical, therapeutic, and prognostic features of this lesion. Copyright © 2010. Published by Elsevier Masson SAS.

  2. Tightening techniques for the retaining screws of universal abutment

    Directory of Open Access Journals (Sweden)

    Alexandre Wittcinski REGALIN

    Full Text Available Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque; and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001. The H20+R technique showed the highest maintained torque (p=0.003, but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque.

  3. Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case-control study.

    Science.gov (United States)

    Taniguchi, N; Jinno, T; Takada, R; Koga, D; Ando, T; Okawa, A; Haro, H

    2018-05-01

    The use of screws and the presence of screw holes may cause acetabular osteolysis and implant loosening in cementless total hip arthroplasty (THA) using conventional polyethylene. In contrast, this issue is not fully understood using highly crosslinked polyethylene (HXLPE), particularly in large comparative study. Therefore, we performed a case-control study to assess the influence of screw usage and screw holes on: (1) implant fixation and osteolysis and (2) polyethylene steady-state wear rate, using cases with HXLPE liners followed up for 7-10 years postoperatively. The screw usage and screw holes adversely affect the implant fixation and incidence of wear-related osteolysis in THA with HXLPE. We reviewed 209 primary cementless THAs performed with 26-mm cobalt-chromium heads on HXLPE liners. To compare the effects of the use of screws and the presence of screw holes, the following groups were established: (1) with-screw (n=140); (2) without-screw (n=69); (3) no-hole (n=27) and (4) group in which a cup with screw holes, but no screw was used (n=42). Two adjunct groups (no-hole cups excluded) were established to compare the differences in the two types of HXLPE: (5) remelted group (n=100) and (6) annealed group (n=82). Implant stability and osteolysis were evaluated by plain radiography and computed tomography. The wear rate from 1 year to the final evaluation was measured using plain X-rays and PolyWare Digital software. All cups and stems achieved bony fixation. On CT-scan, no acetabular osteolysis was found, but there were 3 cases with a small area of femoral osteolysis. The mean steady-state wear rate of each group was (1) 0.031±0.022, (2) 0.033±0.035, (3) 0.031±0.024, (4) 0.029±0.018, (5) 0.030±0.018 and (6) 0.034±0.023mm/year, respectively. A comparison of the effects of screw usage or screw holes found no significant between-group differences in the implant stability, prevalence of osteolysis [no acetabular osteolysis and 3/209 at femoral side (1

  4. Postero-Inferior Pedicle Surgical Technique for the Treatment of Grade III Gynecomastia.

    Science.gov (United States)

    Thiénot, Sophie; Bertheuil, Nicolas; Carloni, Raphaël; Méal, Cécile; Aillet, Sylvie; Herlin, Christian; Watier, Eric

    2017-06-01

    Surgical treatment of Grade III gynecomastia generally utilizes mastectomy techniques and free transplantation of the nipple-areola complex. Moreover, with rising obesity rates and the development of bariatric surgery, an increasing demand for correctional surgery for pseudogynecomastia has been observed, which is comparable to Grade III gynecomastia in terms of its surgical management. Here, we describe an innovative technique to deal with these new demands: fascio-cutaneous flap by postero-inferior pedicle. All patients in the Department of Plastic Surgery from our University Hospital suffering from Grade III gynecomastia or pseudogynecomastia underwent surgery via the postero-inferior pedicle flap technique. Briefly, we performed extensive liposuction of the infero-internal and infero-external mammary quadrants followed by liposuction of the deep tissues of the superior quadrants, except in the area of the pedicle. After removing the skin just above the dermis of the inferior quadrants and performing de-epithelialization of the postero-inferior pedicle flap, the thoracic flap was lowered and the areola transposed. Nine patients underwent surgery between March 2015 and March 2016, and their results were collected prospectively. The mean patient age was 46.6 years, the mean weight was 94.2 kg, and the mean body mass index was 30.8 kg/m 2 . In addition, the mean operative time was 132 min, the mean liposuction volume was 633 mL, the excised weight was 586 g, and the mean hospitalization and drainage durations were 3.8 days. No major complications occurred, no re-intervention was required, and no recurrence was found. We report a new operative technique using a postero-inferior pedicle. Its main advantage is preservation of neurovascular function, which makes this a promising technique for patients who wish to maintain nipple sensitivity. This surgery is reliable and reproducible. We recommend it as the first line treatment for Grade III gynecomastia because

  5. A geometrical introduction to screw theory

    International Nuclear Information System (INIS)

    Minguzzi, E

    2013-01-01

    This work introduces screw theory, a venerable but little known theory aimed at describing rigid body dynamics. This formulation of mechanics unifies in the concept of screw the translational and rotational degrees of freedom of the body. It captures a remarkable mathematical analogy between mechanical momenta and linear velocities, and between forces and angular velocities. For instance, it clarifies that angular velocities should be treated as applied vectors and that, under the composition of motions, they sum with the same rules of applied forces. This work provides a short and rigorous introduction to screw theory intended for an undergraduate and general readership. (paper)

  6. Twin screw wet granulation: Binder delivery.

    Science.gov (United States)

    Saleh, Mohammed F; Dhenge, Ranjit M; Cartwright, James J; Hounslow, Michael J; Salman, Agba D

    2015-06-20

    The effects of three ways of binder delivery into the twin screw granulator (TSG) on the residence time, torque, properties of granules (size, shape, strength) and binder distribution were studied. The binder distribution was visualised through the transparent barrel using high speed imaging as well as quantified using offline technique. Furthermore, the effect of binder delivery and the change of screw configuration (conveying elements only and conveying elements with kneading elements) on the surface velocity of granules across the screw channel were investigated using particle image velocimetry (PIV). The binder was delivered in three ways; all solid binder incorporated with powder mixture, 50% of solid binder mixed with powder mixture and 50% mixed with water, all the solid binder dissolved in water. Incorporation of all solid binder with powder mixture resulted in the relatively longer residence time and higher torque, narrower granule size distribution, more spherical granules, weaker big-sized granules, stronger small-sized granules and better binder distribution compared to that in other two ways. The surface velocity of granules showed variation from one screw to another as a result of uneven liquid distribution as well as shown a reduction while introducing the kneading elements into the screw configuration. Copyright © 2015. Published by Elsevier B.V.

  7. Influência do diâmetro do orifício piloto na resistência ao arrancamento dos parafusos do corpo vertebral The influence of pilot hole diameter on screw pullout resistance

    Directory of Open Access Journals (Sweden)

    Helton L. A. Defino

    2007-01-01

    Full Text Available Foram realizados ensaios mecânicos com o objetivo de avaliar a influência do diâmetro do orifício piloto em relação ao diâmetro interno do parafuso na resistência ao arrancamento dos parafusos do sistema de fixação vertebral aplicados no corpo da vértebra. O estudo foi realizado em duas etapas. Na primeira etapa foram utilizados corpos de prova de poliuretana para a colocação de parafusos de 5mm e, 6mm , e na segunda etapa os parafusos foram inseridos na face lateral dos corpos das vértebras lombares de suínos. O orifício piloto foi realizado com brocas de diâmetro menor, igual ou maior que o diâmetro interno do parafuso. Foram realizados ensaios mecânicos de arrancamento em máquina universal de teste para a avaliação da força máxima de arrancamento dos implantes. Foi observado que o diâmetro do orifício piloto em relação ao diâmetro interno do parafuso influencia na resistência ao arrancamento dos implantes.Mechanical assays were performed in order to assess the influence of pilot hole diameter versus screw's inner diameter on screw pullout resistance in the vertebral fixation systems applied to the vertebral body. The study was conducted in two stages. In the first, polyurethane test bodies were used for placing 5 and 6 mm screws, and, in the second stage, the screws were inserted into the lateral surface of the lumbar vertebral bodies of pigs. The pilot hole was built with drills with smaller, similar or larger diameter than screws' inner diameter. Mechanical pullout assays were performed using a universal test machine for the assessment of maximum pullout screw resistance. The diameter of the pilot hole versus screw's inner diameter was shown to influence screw pullout resistance.

  8. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    Science.gov (United States)

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  9. Lower abdominal wall reconstructions with pedicled rectus femoris flaps

    International Nuclear Information System (INIS)

    Arashiro, Ken; Nishizeki, Osamu; Ishida, Kunihiro

    2003-01-01

    During the past 10 years, seven pedicled rectus femoris muscle or musculocutaneous flaps were used to repair lower abdominal defects; three recalcitrant incisional hernias with previous radiotherapy, two long-standing wound infections after synthetic mesh reconstruction, one posttraumatic wall defect and one metastatic tumor. There were two flap complications, one skin paddle necrosis and one wound infection. There was no significant disability of the donor limb encountered. During the two-year and seven month average follow-up, there was no recurrence of the problems except for one minor fascial dehiscence in the patient with metastatic abdominal wall tumor. Easy approach, rapid harvest, relatively large and reliable overlying fascia lata, a single dominant neurovascular pedicle, easy primary closure of the donor site, and minimal donor site morbidity all make the rectus femoris flap a good alternative flap for lower abdominal wall reconstruction. It is especially useful in a condition where synthetic mesh would be unsuitable for defects with infection or recurrent incisional hernia after radiotherapy. (author)

  10. Development of structural schemes of parallel structure manipulators using screw calculus

    Science.gov (United States)

    Rashoyan, G. V.; Shalyukhin, K. A.; Gaponenko, EV

    2018-03-01

    The paper considers the approach to the structural analysis and synthesis of parallel structure robots based on the mathematical apparatus of groups of screws and on a concept of reciprocity of screws. The results are depicted of synthesis of parallel structure robots with different numbers of degrees of freedom, corresponding to the different groups of screws. Power screws are applied with this aim, based on the principle of static-kinematic analogy; the power screws are similar to the orts of axes of not driven kinematic pairs of a corresponding connecting chain. Accordingly, kinematic screws of the outlet chain of a robot are simultaneously determined which are reciprocal to power screws of kinematic sub-chains. Solution of certain synthesis problems is illustrated with practical applications. Closed groups of screws can have eight types. The three-membered groups of screws are of greatest significance, as well as four-membered screw groups [1] and six-membered screw groups. Three-membered screw groups correspond to progressively guiding mechanisms, to spherical mechanisms, and to planar mechanisms. The four-membered group corresponds to the motion of the SCARA robot. The six-membered group includes all possible motions. From the works of A.P. Kotelnikov, F.M. Dimentberg, it is known that closed fifth-order screw groups do not exist. The article presents examples of the mechanisms corresponding to the given groups.

  11. Technical strategies and anatomic considerations for parapedicular access to thoracic and lumbar vertebral bodies

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Martin, Hal D.; Stapp, Annette M.; Puckett, Timothy A.; Stechison, M.T.; Braswell, John J.

    2007-01-01

    To investigate and illustrate a variation on the traditional percutaneous access to the vertebral body via a parapedicular approach. An effective parapedicular access technique that could safely and reliably guide the needle tip into the center of the vertebral body was developed from cadaver dissection observations for the purpose of clinical use. A total of 102 vertebral compression fractures from T-4 to L-5 were treated via the parapedicular access at our institution between July 2005 and March 2006. There were 72 patients between the ages of 17 and 96 years (mean age: 68.2 years) who underwent treatment. The cadaver dissection revealed a relatively avascular and aneural portion of the vertebral body along the superior margin of the vertebral body-pedicle junction. A total 102 vertebral fractures were treated using the parapedicular access technique without any recognized clinical complications from the needle access or the instrumentation. The thoracic and lumbar vertebral bodies may be safely, reliably, and reproducibly accessed using a percutaneous parapedicular access technique. The technique presented represents a relatively avascular and aneural approach to vertebral body. (orig.)

  12. Fate of the syndesmotic screw--Search for a prudent solution.

    Science.gov (United States)

    Kaftandziev, Igor; Spasov, Marko; Trpeski, Simon; Zafirova-Ivanovska, Beti; Bakota, Bore

    2015-11-01

    Ankle fractures are common injuries. Since the recognition of the importance of syndesmotic injury in ankle fractures, much of the scientific work has been focused on concomitant syndesmotic injury. Despite the invention of novel devices for restoration and maintenance of the congruent syndesmosis following syndesmotic injury, the metallic syndesmotic screw is still considered to be the "gold standard". The aim of this study was to compare the clinical results in patients who retained the syndesmosis screw with those in whom the screw was removed following open reduction and internal fixation of the malleolar fracture associated with syndesmosis disruption. This was a retrospective study of 82 patients. Minimum follow-up was 12 months. Clinical evaluation included American Orthopaedic Foot and Ankle Society (AOFAS) score and Visual Analogue Scale (VAS) for patient general satisfaction. The condition of the screw (removed, intact or broken), presence of radiolucency around the syndesmotic screw and the tibiofibular clear space were recorded using final follow-up radiographs. Three cortices were engaged in 66 patients (80%) and quadricortical fixation was performed in the remaining 16 patients (20%). The number of engaged cortices did not correlate with the clinical outcome and screw fracture. A single syndesmotic screw was used in 71 patients (86%. The mean AOFAS score in the group with intact screw (I) was 83; the scores in the group with broken screw (B) and removed screw (R) were 92.5 and 85.5, respectively. There was a statistically significant difference between the three groups: this was due to the difference between groups I and B; the difference between groups I and R and groups B and R were not statistically significant. There were no statistically significant differences in VAS results. There were no statistically significant differences in clinical outcome between the group with the screw retained and the group in which the screw was removed; however, the

  13. Gossypiboma complicated with paraspinal abscess and lumbar sinus: An uncommon complication of posterior lumbar spinal surgery

    OpenAIRE

    Sahoo, Ranjan Kumar; Tripathy, Pradipta; Das, Pulin Bihari; Mohapatra, Debahuti

    2017-01-01

    A 42-year-old female presented with the complaint of purulent discharging sinus over posterior lumbar area following one month of lumbar spinal surgery for prolapsed intervertebral disc. Gossypiboma complicated with paraspinal abscess and sinus track formation over posterior lumbar area was diagnosed in magnetic resonance imaging which was confirmed in re- exploration of lumbar spinal operative site.

  14. Economics of water injected air screw compressor systems

    Science.gov (United States)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  15. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  16. The Arrival of Robotics in Spine Surgery: A Review of the Literature.

    Science.gov (United States)

    Ghasem, Alexander; Sharma, Akhil; Greif, Dylan N; Alam, Milad; Maaieh, Motasem Al

    2018-04-18

    Systematic Review. The authors aim to review comparative outcome measures between robotic and free-hand spine surgical procedures including: accuracy of spinal instrumentation, radiation exposure, operative time, hospital stay, and complication rates. Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedures has prompted the need for innovation and allowed the emergence of robotics in spine surgery. Prior to incorporation of robotic surgery in routine practice, demonstration of improved instrumentation accuracy, operative efficiency, and patient safety is required. A systematic search of the PubMed, OVID-MEDLINE, and Cochrane databases was performed for papers relevant to robotic assistance of pedicle screw placement. Inclusion criteria were constituted by English written randomized control trials, prospective and retrospective cohort studies involving robotic instrumentation in the spine. Following abstract, title, and full-text review, 32 articles were selected for study inclusion. Intrapedicular accuracy in screw placement and subsequent complications were at least comparable if not superior in the robotic surgery cohort. There is evidence supporting that total operative time is prolonged in robot assisted surgery compared to conventional free-hand. Radiation exposure appeared to be variable between studies; radiation time did decrease in the robot arm as the total number of robotic cases ascended, suggesting a learning curve effect. Multi-level procedures appeared to tend toward earlier discharge in patients undergoing robotic spine surgery. The implementation of robotic technology for pedicle screw placement yields an acceptable level of accuracy on a highly consistent basis. Surgeons should remain vigilant about confirmation of robotic assisted screw trajectory, as drilling pathways have been shown to be altered by soft tissue pressures, forceful surgical application, and bony surface skiving. However, the effective

  17. Comprehensive comparing percutaneous endoscopic lumbar discectomy with posterior lumbar internal fixation for treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis

    Science.gov (United States)

    Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong

    2017-01-01

    Abstract The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery. In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared. The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively. PELD operation was superior in terms of operation time, bleeding volume, recovery period

  18. A case of severe congenital kyphoscoliosis secondary to multiple bilateral thoracic pedicle aplasia

    International Nuclear Information System (INIS)

    Geoffray, Anne; Leloutre, Beatrice; Albertario, Marco; Bechard-Sevette, Nancy; Clement, Jean-Luc

    2008-01-01

    A 9-month-old boy with congenital kyphoscoliosis secondary to multiple bilateral thoracic pedicle aplasias is presented. This anomaly has rarely been described in the literature. Plain films showed absence of thoracic pedicles bilaterally from T2 to T9, which was better demonstrated on CT multiplanar and 3-D reformatted images. There were no neurological symptoms even though the deformity progressed rapidly. Congenital kyphosis or kyphoscoliosis is often related to spinal anomalies that are located on the anterior aspect of the vertebrae. However, posterior anomalies may also be responsible and should be recognized before neurological complications occur. (orig.)

  19. The effect of starting point placement technique on thoracic transverse process strength: an ex vivo biomechanical study

    Directory of Open Access Journals (Sweden)

    Burton Douglas C

    2010-07-01

    Full Text Available Abstract Background The use of thoracic pedicle screws in spinal deformity, trauma, and tumor reconstruction is becoming more common. Unsuccessful screw placement may require salvage techniques utilizing transverse process hooks. The effect of different starting point placement techniques on the strength of the transverse process has not previously been reported. The purpose of this paper is to determine the biomechanical properties of the thoracic transverse process following various pedicle screw starting point placement techniques. Methods Forty-seven fresh-frozen human cadaveric thoracic vertebrae from T2 to T9 were disarticulated and matched by bone mineral density (BMD and transverse process (TP cross-sectional area. Specimens were randomized to one of four groups: A, control, and three others based on thoracic pedicle screw placement technique; B, straightforward; C, funnel; and D, in-out-in. Initial cortical bone removal for pedicle screw placement was made using a burr at the location on the transverse process or transverse process-laminar junction as published in the original description of each technique. The transverse process was tested measuring load-to-failure simulating a hook in compression mode. Analysis of covariance and Pearson correlation coefficients were used to examine the data. Results Technique was a significant predictor of load-to-failure (P = 0.0007. The least squares mean (LS mean load-to-failure of group A (control was 377 N, group B (straightforward 355 N, group C (funnel 229 N, and group D (in-out-in 301 N. Significant differences were noted between groups A and C, A and D, B and C, and C and D. BMD (0.925 g/cm2 [range, 0.624-1.301 g/cm2] was also a significant predictor of load-to-failure, for all specimens grouped together (P P 0.05. Level and side tested were not found to significantly correlate with load-to-failure. Conclusions The residual coronal plane compressive strength of the thoracic transverse process

  20. Screw-worm eradication in the Americas - Overview

    International Nuclear Information System (INIS)

    Wyss, John H.

    2000-01-01

    Screw-worms (Cochliomyia hominivorax, Coquerel) are found only in the Americas, and are known, therefore, as the New World Screw-worm (NWS). The larval stages of the fly feed on the living flesh of their host. A screw-worm infestation can kill an adult animal in 7-10 days if not treated. All warm-blooded animals are affected including man. Although screw-worms had long been recognised as a severe pest of animals in the southwestern United States, they had never been detected east of the Mississippi River before 1933. In July 1933, screw-worms were transported on infested cattle to Georgia and became established east of the Mississippi River. Screw-worms spread quickly in the southeastern United States and were able to overwinter in southern Florida. Being new to the region, they were quickly recognised as a severe pest with a tremendous economic impact on livestock production. The livestock owners in the southeastern United States immediately noticed an increase in the number of animal deaths and increased costs of insecticides, veterinary medicines, veterinary services, inspection and handling. At the same time, they observed a decrease in animal weights and in milk production. Due to these observations, the livestock industry in the southeastern United States requested help in controlling screw-worms. Because of these requests, the research community became interested in control and eradication measures for this pest. Early work by Crushing and Patton in 1933 recognised that C. hominivorax was an obligatory animal parasite and different from the secondary blowfly, Cochliomyia macellaria. In 1934, the US Department of Agriculture (USDA), Agricultural Research Service (ARS) opened a research station in Valdosa, Georgia, and E.W. Laake and E.F. Knipling were assigned to work there. In September 1935, R.C. Bushland was hired by ARS to do research related to screw-worms at an ARS Research Laboratory in Dallas, Texas. Melvin and Bushland in 1936 developed artificial

  1. Spine segmentation from C-arm CT data sets: application to region-of-interest volumes for spinal interventions

    Science.gov (United States)

    Buerger, C.; Lorenz, C.; Babic, D.; Hoppenbrouwers, J.; Homan, R.; Nachabe, R.; Racadio, J. M.; Grass, M.

    2017-03-01

    Spinal fusion is a common procedure to stabilize the spinal column by fixating parts of the spine. In such procedures, metal screws are inserted through the patients back into a vertebra, and the screws of adjacent vertebrae are connected by metal rods to generate a fixed bridge. In these procedures, 3D image guidance for intervention planning and outcome control is required. Here, for anatomical guidance, an automated approach for vertebra segmentation from C-arm CT images of the spine is introduced and evaluated. As a prerequisite, 3D C-arm CT images are acquired covering the vertebrae of interest. An automatic model-based segmentation approach is applied to delineate the outline of the vertebrae of interest. The segmentation approach is based on 24 partial models of the cervical, thoracic and lumbar vertebrae which aggregate information about (i) the basic shape itself, (ii) trained features for image based adaptation, and (iii) potential shape variations. Since the volume data sets generated by the C-arm system are limited to a certain region of the spine the target vertebra and hence initial model position is assigned interactively. The approach was trained and tested on 21 human cadaver scans. A 3-fold cross validation to ground truth annotations yields overall mean segmentation errors of 0.5 mm for T1 to 1.1 mm for C6. The results are promising and show potential to support the clinician in pedicle screw path and rod planning to allow accurate and reproducible insertions.

  2. Co-occurrence of lumbar spondylolysis and lumbar disc herniation with lumbosacral nerve root anomaly

    Science.gov (United States)

    Yılmaz, Tevfik; Turan, Yahya; Gülşen, İsmail; Dalbayrak, Sedat

    2014-01-01

    Lumbosacral nerve root anomalies are the leading cause of lumbar surgery failures. Although co-occurrence of lumbar spondylolysis and disc herniation is common, it is very rare to observe that a nerve root anomaly accompanies these lesions. A 49-year-old male patient presented with sudden-onset right leg pain. Examinations revealed L5/S1 lumbar spondylolysis and disc herniation. At preoperative period, he was also diagnosed with lumbosacral root anomaly. Following discectomy and root decompression, stabilization was performed. The complaints of the patient diagnosed with lumbosacral root anomaly at intraoperative period were improved at postoperative period. It should be remembered that in patients with lumbar disc herniation and spondylolysis, lumbar root anomalies may coexist when clinical and neurological picture is severe. Preoperative and perioperative assessments should be made meticulously to prevent neurological injury. PMID:25210343

  3. Co-occurrence of lumbar spondylolysis and lumbar disc herniation with lumbosacral nerve root anomaly

    Directory of Open Access Journals (Sweden)

    Tevfik Yilmaz

    2014-01-01

    Full Text Available Lumbosacral nerve root anomalies are the leading cause of lumbar surgery failures. Although co-occurrence of lumbar spondylolysis and disc herniation is common, it is very rare to observe that a nerve root anomaly accompanies these lesions. A 49-year-old male patient presented with sudden-onset right leg pain. Examinations revealed L5/S1 lumbar spondylolysis and disc herniation. At preoperative period, he was also diagnosed with lumbosacral root anomaly. Following discectomy and root decompression, stabilization was performed. The complaints of the patient diagnosed with lumbosacral root anomaly at intraoperative period were improved at postoperative period. It should be remembered that in patients with lumbar disc herniation and spondylolysis, lumbar root anomalies may coexist when clinical and neurological picture is severe. Preoperative and perioperative assessments should be made meticulously to prevent neurological injury.

  4. Conceptual design of ball-screw type control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Ho; Kim, Jong In; Huh, Hyung [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In this report, the design features of ball-screw type CEDM with fine-step movement capability are described. The contents of this report are as follows: -Review of Design Requirements for Ball-screw type CEDM -System Description for Ball-screw type CEDM -Design of Ball Bearing and Ball-screw Assembly -Detail Design of Rotary Step Motor -Detail Design of Angular Position Indicator -Materials. The Ball-screw type CEDM described in this report is to be utilized as the starting point for design development of CEDM for SMART. 11 refs., 43 figs., 3 tabs. (Author)

  5. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract.

    Science.gov (United States)

    Leitner, L; Brückmann, C I; Gilg, M M; Bratschitsch, G; Sadoghi, P; Leithner, A; Radl, R

    2017-01-01

    Purpose . Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods . We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results . A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI) tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion . Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  6. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    L. Leitner

    2017-01-01

    Full Text Available Purpose. Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods. We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results. A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion. Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  7. Safety and surgical techniques of C1 lateral mass screws

    International Nuclear Information System (INIS)

    Kubo, Shinichiro; Kuroki, Hiroshi; Hanado, Shoji; Hamanaka, Hideaki; Inomata, Naoki; Kuroki, Shuji; Chosa, Etsuo

    2010-01-01

    The objectives of this study were to evaluate the proper insertion techniques of C1 lateral mass screws. Eighteen consecutive patients were examined after upper cervical fusion using twenty-nine C1 lateral mass screws. Screws were placed by three different techniques; Goel's technique (4), Tan's technique (20), Notching technique (5). Pre and post-operative CT scans with multiplanar reconstruction were used to detect cortical breaches and direction of screws. No transverse foramen and vertebral groove violation was found in CT scans. Three had breached superior articular facet of the atlas. However, the range of motion (R.O.M) of atlanto-occipital joints had not changed postoperatively. Theses screws were inserted with Tan's technique and two of three were directed medially. It is feasible to safely insert C1 lateral mass screws when correct insertion point and direction are considered preoperatively. However, care should be taken because screws can violate the atlanto-occipital joint especially with Tan's technique. (author)

  8. The use of pedicled prepucial skin flap urethroplasty for proximal ...

    African Journals Online (AJOL)

    The use of pedicled prepucial skin flap urethroplasty for proximal bulbomembraneous urethral stricture in children: an easy alternative to transpubic urethroplasty. Harshjeet S. Bal, Jujju J. Kurian and Sudipta Sen. Objective Pediatric urethral strictures are not uncommon, and a myriad of treatment options is available.

  9. Lumbar lordosis.

    Science.gov (United States)

    Been, Ella; Kalichman, Leonid

    2014-01-01

    Lumbar lordosis is a key postural component that has interested both clinicians and researchers for many years. Despite its wide use in assessing postural abnormalities, there remain many unanswered questions regarding lumbar lordosis measurements. Therefore, in this article we reviewed different factors associated with the lordosis angle based on existing literature and determined normal values of lordosis. We reviewed more than 120 articles that measure and describe the different factors associated with the lumbar lordosis angle. Because of a variety of factors influencing the evaluation of lumbar lordosis such as how to position the patient and the number of vertebrae included in the calculation, we recommend establishing a uniform method of evaluating the lordosis angle. Based on our review, it seems that the optimal position for radiologic measurement of lordosis is standing with arms supported while shoulders are flexed at a 30° angle. There is evidence that many factors, such as age, gender, body mass index, ethnicity, and sport, may affect the lordosis angle, making it difficult to determine uniform normal values. Normal lordosis should be determined based on the specific characteristics of each individual; we therefore presented normal lordosis values for different groups/populations. There is also evidence that the lumbar lordosis angle is positively and significantly associated with spondylolysis and isthmic spondylolisthesis. However, no association has been found with other spinal degenerative features. Inconclusive evidence exists for association between lordosis and low back pain. Additional studies are needed to evaluate these associations. The optimal lordotic range remains unknown and may be related to a variety of individual factors such as weight, activity, muscular strength, and flexibility of the spine and lower extremities. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Process and remote device for unscrewing and extracting an assembly screw

    International Nuclear Information System (INIS)

    Lagarrigue, F.

    1990-01-01

    The device comprises a C-shaped frame, with two parallel arms and a joining section fixed at one end of a long support, an extraction screw engaged in a hole through one arm and having one end made of a centre punch directed towards the inside of the frame and a remote mean for screwed or unscrewed the extraction screw. A supporting and centering piece can also be fixed to the second branch of the frame. The screw is extracted by exerting a moment about the axis of the screw through the support and frame after tightening the extraction screw. This device can be used particularly for the unscrewing and the extraction of the screw of the springs of a nuclear fuel assembly [fr

  11. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    Science.gov (United States)

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  12. Phalloplasty with an Innervated Island Pedicled Anterolateral Thigh Flap in a Female-to-Male Transsexual

    OpenAIRE

    Hasegawa, Kenjiro; Namba, Yuzaburo; Kimata, Yoshihiro

    2013-01-01

    Since 2001, we have been performing phalloplasty with a radial forearm free flap as the flap of first choice in female-to-male transsexuals (FTMTS). In the present case, a 22-year-old FTMTS with a negative Allen test, we achieved good results by performing phalloplasty with an innervated island pedicled anterolateral thigh flap using the "tube within a tube" technique, in which the penis and urethra are constructed with a single flap. While phalloplasty with an island-pedicled or free anterol...

  13. BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.

    Science.gov (United States)

    Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz

    2009-01-01

    To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.

  14. Enlargement of lumbar spinal canal in lumbar degenerative spondylolisthesis. Evaluation with three-dimensional computed tomography

    International Nuclear Information System (INIS)

    Kunishi, Yoshihiko

    2003-01-01

    A number of clinical studies have demonstrated that enlargement of the lumbar spinal canal is one of the effective surgical procedures for the treatment of the lumbar degenerative spondylolisthesis and provides a good result. In the present study, we have evaluated the long-term outcome of the enlargement of the lumbar canal without fusion in thirty eight patients with lumbar degenerative spondylolisthesis using three-dimensional computed tomography (3D-CT) The improvement rate was excellent in 80% of the patients (mean improvement ratio, 83%) according to the Japanese Orthopedic Association scoring system. We found that the sufficient enlargement of the canal was obtained by the surgery and maintained for a long period of time. The results from 3D-CT suggested that a round shape was maintained in the canal after the surgery because of pressures of the dura mater against to the bony canal. None of patients showed lumbar instability. In conclusion, enlargement of lumbar canal without fusion is useful for the treatment of lumbar degenerative spondylolisthesis, and the enlarged canal has been maintained for a long period of time after the surgery. The results demonstrated the clinical utility of 3D-CT to evaluate the preoperative and postoperative shape of the spine. (author)

  15. Posterior Rigid Instrumentation of C7: Surgical Considerations and Biomechanics at the Cervicothoracic Junction. A Review of the Literature.

    Science.gov (United States)

    Bayoumi, Ahmed B; Efe, Ibrahim E; Berk, Selim; Kasper, Ekkehard M; Toktas, Zafer Orkun; Konya, Deniz

    2018-03-01

    The cervicothoracic junction is a challenging anatomic transition in spine surgery. It is commonly affected by different types of diseases that may significantly impair stability in this region. The seventh cervical vertebra (C7) is an atypical cervical vertebra with unique anatomic features compared to subaxial cervical spine (C3 to C6). C7 has relatively broader laminae, larger pedicles, smaller lateral masses, and a long nonbifid spinous process. These features allow a variety of surgical methods for performing posterior rigid instrumentation in the form of different types of screws, such as lateral mass screws, pedicle screws, transfacet screws, and intralaminar screws. Many biomechanical studies on cadavers have evaluated and compared different types of implants at C7. We reviewed PubMed/Medline by using specific combinations of keywords to summarize previously published articles that examined C7 posterior rigid instrumentation thoroughly in an experimental fashion on patients or cadavers with additional descriptive radiologic parameters for evaluation of the optimum surgical technique for each type. A total of 44 articles were reported, including 22 articles that discussed anatomic considerations (entry points, sagittal and axial trajectories, and features of screws) and another 22 articles that discussed the relevant biomechanical testing at this transitional region if C7 was directly involved in terms of receiving posterior rigid implants. C7 can accommodate different types of screws, which can provide additional benefits and risks based on availability of bony purchase, awareness of surgical technique, biomechanics, and anatomic considerations. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Monitoração intraoperatória com teste de estimulação eletromiográfica dos instrumentais de pacientes submetidos à correção cirúrgica de escoliose idiopática Seguimiento de estimulación intraoperatoria con electromiografía de los instrumentales de pacientes sometidos a corrección quirúrgica de la escoliosis idiopática Intraoperative neurophysiological monitoring of patients undergoing idiopathic scoliosis surgical correction

    Directory of Open Access Journals (Sweden)

    Wagner Pasqualini

    2010-09-01

    Full Text Available OBJETIVO: apresentar a metodologia empregada na monitoração neurofisiológica de pacientes submetidos a tratamento para correção de escoliose idiopática com instrumentação cirúrgica, utilizando parafusos pediculares torácicos e lombares. MÉTODOS: foram estudados, retrospectivamente, 32 prontuários de pacientes operados no Serviço de Cirurgia da Coluna Vertebral do Instituto da Coluna,Jundiaí, São Paulo, entre os anos de 2004 e 2008. A idade variou de 11 a 18 anos, e a maioria era do sexo feminino (93,75%. RESULTADOS: verificou-se que em seis pacientes houve relação entre a incidência de positividade no teste com estimulação eletromiográfica dos instrumentais e mau posicionamento dos parafusos pediculares, sem evidências de complicações após correção dos mesmos. CONCLUSÃO: os resultados confirmam a eficácia da monitoração intraoperatória.OBJETIVO: presentar la metodología utilizada en la vigilancia neurofisiológica de los pacientes sometidos al tratamiento de corrección de la escoliosis idiopática, con el uso de instrumentación quirúrgica, utilizando tornillos pediculares torácicos y lumbares. MÉTODOS: se estudiaron 32 pacientes operados en el Servicio de Cirugía del Raquis del Instituto de la Columna (Jundiaí, en el Brasil, entre 2004 y 2008. Las edades oscilaban entre los 11 a 18 años y la mayoría era mujeres (93,75%. RESULTADOS: se ha detectado en seis pacientes la relación entre la incidencia de positivo en la prueba de estimulación con electromiografía de los instrumentales y la mala colocación de los tornillos pediculares, sin evidencias de complicaciones después de la corrección de los mismos. CONCLUSIÓN: los resultados confirman la eficacia de la monitorización intraoperatoria.OBJECTIVE: to present the methodology used for neurophysiological monitoring of patients undergoing idiopathic scoliosis correction with surgical instrumentation, using thoracic and lumbar pedicle screws. METHODS

  17. NEUROMUSCULAR CONTROL IN LUMBAR DISORDERS

    Directory of Open Access Journals (Sweden)

    Ville Leinonen

    2004-03-01

    Full Text Available Impaired motor and sensory functions have been associated with low back pain (LBP. This includes disturbances in a wide range of sensorimotor control e.g. sensory dysfunctions, impaired postural responses and psychomotor control. However, the physiological mechanisms, clinical relevance and characteristics of these findings in different spinal pathologies require further clarification. The purposes of this study were to investigate postural control, lumbar muscle function, movement perception and associations between these findings in healthy volunteers (n=35, patients with lumbar disc herniation (n=20 and lumbar spinal stenosis (LSS, n=26. Paraspinal muscle responses for sudden upper limb loading and muscle activation during flexion-extension movement and the lumbar endurance test were measured by surface electromyography (EMG. Postural stability was measured on a force platform during two- and one-footed standing. Lumbar movement perception was assessed in a motorised trunk rotation unit in the seated position. In addition, measurements of motor-(MEP and somatosensory evoked potentials (SEP and needle EMG examination of lumbar multifidus muscles were performed in the LSS patients. Clinical and questionnaire data were also recorded. A short latency paraspinal muscle response (~50 ms for sudden upper limb loading was observed. The latency of the response was shortened by expectation (p=0.017. The response latency for unexpected loading was similar in healthy persons and disc herniation patients but the latency was not shortened by expectation in the patients (p = 0.014. Also impaired postural control (p < 0.05 and lumbar movement perception (p = 0.012 were observed in disc herniation patients. The impaired lumbar movement perception (p=0.054 and anticipatory muscle activation (p = 0.043 tended to be restored after successful surgery but postural control had still not recovered after 3 months of follow-up. The majority of LSS patients were unable

  18. The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.

    Science.gov (United States)

    Akamaru, Tomoyuki; Kawahara, Norio; Sakamoto, Jiro; Yoshida, Akira; Murakami, Hideki; Hato, Taizo; Awamori, Serina; Oda, Juhachi; Tomita, Katsuro

    2005-12-15

    A finite-element study of posterior alone or anterior/posterior combined instrumentation following total spondylectomy and replacement with a titanium mesh cage used as an anterior strut. To compare the effect of posterior instrumentation versus anterior/posterior instrumentation on transmission of the stress to grafted bone inside a titanium mesh cage following total spondylectomy. The most recent reconstruction techniques following total spondylectomy for malignant spinal tumor include a titanium mesh cage filled with autologous bone as an anterior strut. The need for additional anterior instrumentation with posterior pedicle screws and rods is controversial. Transmission of the mechanical stress to grafted bone inside a titanium mesh cage is important for fusion and remodeling. To our knowledge, there are no published reports comparing the load-sharing properties of the different reconstruction methods following total spondylectomy. A 3-dimensional finite-element model of the reconstructed spine (T10-L4) following total spondylectomy at T12 was constructed. A Harms titanium mesh cage (DePuy Spine, Raynham, MA) was positioned as an anterior replacement, and 3 types of the reconstruction methods were compared: (1) multilevel posterior instrumentation (MPI) (i.e., posterior pedicle screws and rods at T10-L2 without anterior instrumentation); (2) MPI with anterior instrumentation (MPAI) (i.e., MPAI [Kaneda SR; DePuy Spine] at T11-L1); and (3) short posterior and anterior instrumentation (SPAI) (i.e., posterior pedicle screws and rods with anterior instrumentation at T11-L1). The mechanical energy stress distribution exerted inside the titanium mesh cage was evaluated and compared by finite-element analysis for the 3 different reconstruction methods. Simulated forces were applied to give axial compression, flexion, extension, and lateral bending. In flexion mode, the energy stress distribution in MPI was higher than 3.0 x 10 MPa in 73.0% of the total volume inside

  19. Clinical application of percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation under CT guidance

    International Nuclear Information System (INIS)

    Wang Linyou; Li Yuan; Shao Yangtong

    2004-01-01

    Objective: To evaluate the effect of the percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation. Methods: 75 cases of lumbar disc herniation with significant clinical signs were confirmed by CT scan. The technique of the percutaneous lumbar puncture led the needle to approach nerve root and injected medicine diffusing into extraduramater, and then relieved the symptom of sciatica. Results: The rate of success of percutaneous lumbar puncture guided by CT reached to 100%. After two weeks of follow-up, the symptom of pain was obviously improved and disappeared in 63.3% cases. There were 23.0% cases needed a second procedure, and no change was obsesved in 9.3% cases. Conclusions: The percutaneous lumbar puncture guided by CT to treat sciatica resulted from lumbar disc herniation is one of the safe, reliable, effective new methods with no complication. The long term effectiveness is still in need of investigation. (authors)

  20. Modeling and Analyzing the Slipping of the Ball Screw

    Directory of Open Access Journals (Sweden)

    Nannan Xu

    Full Text Available AbstractThis paper aims to set up the ball systematic slipping model and analyze the slipping characteristics caused by different factors for a ball screw operating at high speeds. To investigate the ball screw slipping mechanism, transformed coordinate system should be established firstly. Then it is used to set up mathematical modeling for the ball slipping caused by the three main reasons and the speed of slipping can be calculated. Later, the influence of the contact angle, helix angle and screw diameter for ball screw slipping will be analyzed according to the ball slipping model and slipping speeds equation and the slipping analysis will be obtained. Finally, curve of slipping analysis and that of mechanical efficiency of the ball screw analysis by Lin are compared, which will indirectly verify the correctness of the slipping model. The slipping model and the curve of slipping analysis established in this paper will provide theory basis for reducing slipping and improving the mechanical efficiency of a ball screw operating at high speeds.

  1. Imaging appearances and clinical outcome following sacrectomy and ilio-lumbar reconstruction for sacral neoplasia

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Marianna; Davies, A.M.; James, Steven L.J. [Department of Radiology, The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham (United Kingdom); Stirling, A.J.; Grainger, M. [Department of Spinal Surgery, The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham (United Kingdom); Grimer, R.J. [Department of Orthopaedic Oncology, The Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham (United Kingdom)

    2014-02-15

    Sacrectomy and ilio-lumbar reconstruction is an uncommonly performed complex surgical procedure for the treatment of sacral neoplasia. There are many challenges in the post-operative period including the potential for tumor recurrence, infection, and construct failure. We present our experience of this patient cohort and describe the complications and imaging appearances that can be encountered during the follow-up period. Retrospective review of our Orthopaedic Oncology database was undertaken which has been collected over a 30-year period to identify patients that had undergone sacrectomy and ilio-lumbar reconstruction. Pre and post-operative imaging including radiographs, CT, and MRI was reviewed. These were viewed by two experienced musculoskeletal radiologists with consensus opinion if there was disagreement over the imaging findings. Data regarding patient demographics, tumor type, and dimensions was collected. Serial review of radiographs, CT, and MRI was performed to assess implant position and integrity, strut graft position and union, and for the presence of recurrence within the surgical bed. Five male and two female patients (mean age 36 years, age range 15-54 years) were treated with this procedure. Histological diagnoses included chordoma, chondrosarcoma, osteosarcoma, and spindle cell sarcoma. Mean maximal tumor size on pre-operative imaging was 10.7 cm (range, 6-16 cm). Post-operative follow-up ranged from 10-46 months. A total of 76 imaging studies were reviewed. Commonly identified complications included vertical rod and cross-connector fracture and screw loosening. Fibula strut graft non-union and fracture was also evident on imaging review. Two patients demonstrated disease recurrence during the follow-up period. This study demonstrates the spectrum and frequency of complications that can occur following sacrectomy and ilio-lumbar reconstruction for sacral neoplasia. (orig.)

  2. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study.

    Science.gov (United States)

    Kanneganti, Krishna Chaitanya; Vinnakota, Dileep Nag; Pottem, Srinivas Rao; Pulagam, Mahesh

    2018-01-01

    The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  3. A four lumen screwing device for multiparametric brain monitoring.

    Science.gov (United States)

    Feuerstein, T H; Langemann, H; Gratzl, O; Mendelowitsch, A

    2000-01-01

    We describe multiparametric monitoring in severe head trauma using a new screwing device. Our aim was to create a screw which would make the implantation of the probes and thus multiparametric monitoring easier. The new screw allows us to implant 3 probes (microdialysis, Paratrend and an intracranial pressure device) through one burr hole. The screw has four channels, the fourth being for ventricular drainage. We monitored 13 patients with severe head trauma (GCS = 3-8) for up to 7 days. Brain tissue pO2, pCO2, pH, and temperature were measured on-line with the Paratrend 7 machine. The microdialytic parameters glucose, lactate, pyruvate and glutamate were determined semi on-line with a CMA 600 enzymatic analyser. There were no complications in any of the patients that could be ascribed to the screw.

  4. Experiments on screw-pinch plasmas with elongated cross section

    International Nuclear Information System (INIS)

    Lassing, H.W.

    1989-01-01

    In this thesis experiments are described carried out with SPICA II, a toroidal screw-pinch plasma device. this device is the last one in a series of plasma machines of the toroidal screw-pinch differing from its predecessor in its race-track shaped section. In devices of the type toroidal screw-pinch stable confinement is possible of plasmas with larger β values than in a tokamak discharge. In a pinch the plasma is screwed up, during the formation, in such a way that in a relatively small volume a plasma is formated with a high pressure. During the screwing up the plasma is heated by shock heating as well as adiabatic compression. With the modified snowplow model the density and temperature after the formation can be calculated, starting from the initial conditions. When all ions arrive into the plasma column, the density in the column is determined by the volume compression. First purpose of the experiments was to find a stable discharge. Subsequently discharges have been made with a high as possible β in order to investigate at which maximum β it is possible to confine screw-pinch plasmas stably. When these had been found, the nature and importance could be investigated of the processes following which the screw-pinch plasma looses its energy. (author), 75 res.; 95 figs.; 8 tabs

  5. Determination of Screw and Nail Withdrawal Resistance of Some Important Wood Species

    Directory of Open Access Journals (Sweden)

    Alper Aytekin

    2008-04-01

    Full Text Available In this study, screw and nail withdrawal resistance of fir (Abies nordmanniana, oak (Quercus robur L. black pine (Pinus nigra Arnold and Stone pine (Pinus pinea L. wood were determined and compared. The data represent the testing of withdrawal resistance of three types of screws as smart, serrated and conventional and common nails. The specimens were prepared according to TS 6094 standards. The dimensions of the specimens were 5x5x15cm and for all of the directions. Moreover, the specimens were conditioned at ambient room temperature and 65±2% relative humidity. The screws and nails were installed according to ASTM-D 1761 standards. Nail dimensions were 2.5mm diameter and 50 mm length, conventional screws were 4x50mm, serrated screws were 4x45mm and smart screws were 4x50mm. Results show that the maximum screw withdrawal resistance value was found in Stone pine for the serrated screw. There were no significant differences between Stone pine and oak regarding screw withdrawal resistance values. Conventional screw yielded the maximum screw withdrawal resistance value in oak, followed by Stone pine, black pine and fir. Oak wood showed the maximum screw withdrawal resistance value for the smart screw, followed by Stone pine, black pine, and fir. Oak wood showed higher nail withdrawal resistances than softwood species. It was also determined that oak shows the maximum nail withdrawal resistance in all types. The nail withdrawal resistances at the longitudinal direction are lower with respect to radial and tangential directions.

  6. Enhancement of Orthodontic Anchor Screw Stability Under Immediate Loading by Ultraviolet Photofunctionalization Technology.

    Science.gov (United States)

    Takahashi, Maiko; Motoyoshi, Mitsuru; Inaba, Mizuki; Hagiwara, Yoshiyuki; Shimizu, Noriyoshi

    Ultraviolet (UV)-mediated photofunctionalization technology is intended to enhance the osseointegration capability of titanium implants. There are concerns about orthodontic anchor screws loosening under immediate loading protocols in adolescent orthodontic treatment. The purpose of this in vivo study was to evaluate the effects of photofunctionalization on the intrabony stability of orthodontic titanium anchor screws and bone-anchor screw contact under immediate loading in growing rats. Custom-made titanium anchor screws (1.4 mm in diameter and 4.0 mm in length) with or without photofunctionalization pretreatment were placed on the proximal epiphysis of the tibial bone in 6-week-old male Sprague-Dawley rats and were loaded immediately after placement. After 2 weeks of loading, the stability of the anchor screws was evaluated using a Periotest device, and the bone-anchor screw contact ratio (BSC) was assessed by a histomorphometric analysis using field-emission scanning electron microscopy. In the unloaded group, Periotest values (PTVs) were ~25 for UV-untreated screws and 13 for UVtreated screws (P < .01), while in the immediate-loading group, PTVs were 28 for UV-untreated screws and 16 for UV-treated screws (P < .05). Significantly less screw mobility was observed in both UV-treated groups regardless of the loading protocol. The BSC was increased ~1.8 fold for UV-treated screws, compared with UV-untreated screws, regardless of the loading protocol. Photofunctionalization enhanced the intrabony stability of orthodontic anchor screws under immediate loading in growing rats by increasing bone-anchor screw contact.

  7. Economics of water injected air screw compressor systems

    OpenAIRE

    Madhav, K. V.; Kovacevic, A.

    2015-01-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an in...

  8. Lumbar Scoliosis Combined Lumbar Spinal Stenosis and Herniation Diagnosed Patient Was Treated with “U” Route Transforaminal Percutaneous Endoscopic Lumbar Discectomy

    Directory of Open Access Journals (Sweden)

    Binbin Wu

    2017-01-01

    Full Text Available The objective was to report a case of a 63-year-old man with a history of low back pain (LBP and left leg pain for 2 years, and the symptom became more serious in the past 5 months. The patient was diagnosed with lumbar scoliosis combined with lumbar spinal stenosis (LSS and lumbar disc herniation (LDH at the level of L4-5 that was confirmed using Computerized Topography and Magnetic Resonance Imaging. The surgical team preformed a novel technique, “U” route transforaminal percutaneous endoscopic lumbar discectomy (PELD, which led to substantial, long-term success in reduction of pain intensity and disability. After removing the osteophyte mass posterior to the thecal sac at L4-5, the working channel direction was changed to the gap between posterior longitudinal ligament and thecal sac, and we also removed the herniation and osteophyte at L3-4 with “U” route PELD. The patient’s symptoms were improved immediately after the surgical intervention; low back pain intensity decreased from preoperative 9 to postoperative 2 on a visual analog scale (VAS recorded at 1 month postoperatively. The success of the intervention suggests that “U” route PELD may be a feasible alternative to treat lumbar scoliosis with LSS and LDH patients.

  9. Lumbar lordosis in female collegiate dancers and gymnasts.

    Science.gov (United States)

    Ambegaonkar, Jatin P; Caswell, Amanda M; Kenworthy, Kristen L; Cortes, Nelson; Caswell, Shane V

    2014-12-01

    Postural deviations can predispose an individual to increased injury risk. Specifically, lumbar deviations are related to increased low back pain and injury. Dancers and gymnasts are anecdotally suggested to have exaggerated lumbar lordosis and subsequently may be at increased risk of lumbar pathologies. Our objective was to examine lumbar lordosis levels in dancers and gymnasts. We examined lumbar lordosis in 47 healthy collegiate females (17 dancers, 29 gymnasts; mean age 20.2 ± 1.6 yrs) using 2-dimensional sagittal plane photographs and the Watson MacDonncha Posture Analysis instrument. Participants' lordosis levels were cross-tabulated and a Mann-Whitney U-test compared lumbar lordosis between groups (plordosis deviations. The distribution of lordosis was similar across groups (p=0.22). Most dancers and gymnasts had moderate or marked lumbar lordosis. The extreme ranges of motion required during dancing and gymnastics may contribute to the participants' high lumbar lordosis. Instructors should be aware that there may be links between repetitive hyperextension activities and lumbar lordosis levels in dancers and gymnasts. Thus, they should proactively examine lumbar lordosis in their dancers and gymnasts. How much age of training onset, regimens, survivor bias, or other factors influence lumbar lordosis requires study. Longitudinal studies are also needed to determine if lumbar lordosis levels influence lumbar injury incidence in dancers and gymnasts.

  10. Lumbar radiculopathy due to unilateral facet hypertrophy following lumbar disc hernia operation: a case report.

    Science.gov (United States)

    Kökeş, Fatih; Günaydin, Ahmet; Aciduman, Ahmet; Kalan, Mehmet; Koçak, Halit

    2007-10-01

    To present a radiculopathy case due to unilateral facet hypertrophy developing three years after a lumbar disc hernia operation. A fifty two-year-old female patient, who had been operated on for a left L5-S1 herniated lumbar disc three years ago, was hospitalized and re-operated with a diagnosis of unilateral facet hypertrophy. She had complaints of left leg pain and walking restrictions for the last six months. Left Straight Leg Raising test was positive at 40 degrees , left ankle dorsiflexion muscle strength was 4/5, left Extensor Hallucis Longus muscle strength was 3/5, and left Achilles reflex was hypoactive. Lumbar spinal Magnetic Resonance Imaging revealed left L5-S1 facet hypertrophy. Lumbar radiculopathy due to lumbar facet hypertrophy is a well-known neurological condition. Radicular pain develops during the late postoperative period following lumbar disc hernia operations that are often related to recurrent disc herniation or to formation of post-operative scar tissue. In addition, it can be speculated that unilateral facet hypertrophy, which may develop after a disc hernia operation, might also be one of the causes of radiculopathy.

  11. Spinaplasty following lumbar laminectomy for multilevel lumbar spinal stenosis to prevent iatrogenic instability

    Directory of Open Access Journals (Sweden)

    Surendra Mohan Tuli

    2011-01-01

    Conclusion: Spinaplasty following posterior decompression for multilevel lumbar canal stenosis is a simple operation, without any serious complications, retaining median structures, maintaining the tension band and the strength with least disturbance of kinematics, mobility, stability and lordosis of the lumbar spine.

  12. Preoperative CT planning of screw length in arthroscopic Latarjet.

    Science.gov (United States)

    Hardy, Alexandre; Gerometta, Antoine; Granger, Benjamin; Massein, Audrey; Casabianca, Laurent; Pascal-Moussellard, Hugues; Loriaut, Philippe

    2018-01-01

    The Latarjet procedure has shown its efficiency for the treatment of anterior shoulder dislocation. The success of this technique depends on the correct positioning and fusion of the bone block. The length of the screws that fix the bone block can be a problem. They can increase the risk of non-union if too short or be the cause of nerve lesion or soft tissue discomfort if too long. Suprascapular nerve injuries have been reported during shoulder stabilisation surgery up to 6 % of the case. Bone block non-union depending on the series is found around 20 % of the cases. The purpose of this study was to evaluate the efficiency of this CT preoperative planning to predict optimal screws length. The clinical importance of this study lies in the observation that it is the first study to evaluate the efficiency of CT planning to predict screw length. Inclusion criteria were patients with chronic anterior instability of the shoulder with an ISIS superior to 4. Exclusion criteria were patients with multidirectional instability or any previous surgery on this shoulder. Thirty patients were included prospectively, 11 of them went threw a CT planning, before their arthroscopic Latarjet. Optimal length of both screws was calculated, adding the size of the coracoid at 5 and 15 mm from the tip to the glenoid. Thirty-two-mm screws were used for patients without planning. On a post-operative CT scan with 3D reconstruction, the distance between the screw tip and the posterior cortex was measured. A one-sample Wilcoxon test was used to compare the distance from the tip of the screw to an acceptable positioning of ±2 mm from the posterior cortex. In the group without planning, screw 1 tended to differ from the acceptable positioning: mean 3.44 mm ± 3.13, med 2.9 mm, q1; q3 [0.6; 4.75] p = 0.1118, and screw 2 differed significantly from the acceptable position: mean 4.83 mm ± 4.11, med 3.7 mm, q1; q3 [1.7; 5.45] p = 0.0045. In the group with planning, position of

  13. Lumbar stenosis: clinical case

    Directory of Open Access Journals (Sweden)

    Pedro Sá

    2014-08-01

    Full Text Available Lumbar stenosis is an increasingly common pathological condition that is becoming more frequent with increasing mean life expectancy, with high costs for society. It has many causes, among which degenerative, neoplastic and traumatic causes stand out. Most of the patients respond well to conservative therapy. Surgical treatment is reserved for patients who present symptoms after implementation of conservative measures. Here, a case of severe stenosis of the lumbar spine at several levels, in a female patient with pathological and surgical antecedents in the lumbar spine, is presented. The patient underwent two different decompression techniques within the same operation.

  14. Simple prediction method of lumbar lordosis for planning of lumbar corrective surgery: radiological analysis in a Korean population.

    Science.gov (United States)

    Lee, Chong Suh; Chung, Sung Soo; Park, Se Jun; Kim, Dong Min; Shin, Seong Kee

    2014-01-01

    This study aimed at deriving a lordosis predictive equation using the pelvic incidence and to establish a simple prediction method of lumbar lordosis for planning lumbar corrective surgery in Asians. Eighty-six asymptomatic volunteers were enrolled in the study. The maximal lumbar lordosis (MLL), lower lumbar lordosis (LLL), pelvic incidence (PI), and sacral slope (SS) were measured. The correlations between the parameters were analyzed using Pearson correlation analysis. Predictive equations of lumbar lordosis through simple regression analysis of the parameters and simple predictive values of lumbar lordosis using PI were derived. The PI strongly correlated with the SS (r = 0.78), and a strong correlation was found between the SS and LLL (r = 0.89), and between the SS and MLL (r = 0.83). Based on these correlations, the predictive equations of lumbar lordosis were found (SS = 0.80 + 0.74 PI (r = 0.78, R (2) = 0.61), LLL = 5.20 + 0.87 SS (r = 0.89, R (2) = 0.80), MLL = 17.41 + 0.96 SS (r = 0.83, R (2) = 0.68). When PI was between 30° to 35°, 40° to 50° and 55° to 60°, the equations predicted that MLL would be PI + 10°, PI + 5° and PI, and LLL would be PI - 5°, PI - 10° and PI - 15°, respectively. This simple calculation method can provide a more appropriate and simpler prediction of lumbar lordosis for Asian populations. The prediction of lumbar lordosis should be used as a reference for surgeons planning to restore the lumbar lordosis in lumbar corrective surgery.

  15. On Helical Projection and Its Application in Screw Modeling

    Directory of Open Access Journals (Sweden)

    Riliang Liu

    2014-04-01

    Full Text Available As helical surfaces, in their many and varied forms, are finding more and more applications in engineering, new approaches to their efficient design and manufacture are desired. To that end, the helical projection method that uses curvilinear projection lines to map a space object to a plane is examined in this paper, focusing on its mathematical model and characteristics in terms of graphical representation of helical objects. A number of interesting projective properties are identified in regard to straight lines, curves, and planes, and then the method is further investigated with respect to screws. The result shows that the helical projection of a cylindrical screw turns out to be a Jordan curve, which is determined by the screw's axial profile and number of flights. Based on the projection theory, a practical approach to the modeling of screws and helical surfaces is proposed and illustrated with examples, and its possible application in screw manufacturing is discussed.

  16. Accuracy of S2 Alar-Iliac Screw Placement Under Robotic Guidance.

    Science.gov (United States)

    Laratta, Joseph L; Shillingford, Jamal N; Lombardi, Joseph M; Alrabaa, Rami G; Benkli, Barlas; Fischer, Charla; Lenke, Lawrence G; Lehman, Ronald A

    Case series. To determine the safety and feasibility of S2 alar-iliac (S2AI) screw placement under robotic guidance. Similar to standard iliac fixation, S2AI screws aid in achieving fixation across the sacropelvic junction and decreasing S1 screw strain. Fortunately, the S2AI technique minimizes prominent instrumentation and the need for offset connectors to the fusion construct. Herein, we present an analysis of the largest series of robotic-guided S2AI screws in the literature without any significant author conflicts of interest with the robotics industry. Twenty-three consecutive patients who underwent spinopelvic fixation with 46 S2AI screws under robotic guidance were analyzed from 2015 to 2016. Screws were placed by two senior spine surgeons, along with various fellow or resident surgical assistants, using a proprietary robotic guidance system (Renaissance; Mazor Robotics Ltd., Caesara, Israel). Screw position and accuracy was assessed on intraoperative CT O-arm scans and analyzed using three-dimensional interactive viewing and manipulation of the images. The average caudal angle in the sagittal plane was 31.0° ± 10.0°. The average horizontal angle in the axial plane using the posterior superior iliac spine as a reference was 42.8° ± 6.6°. The average S1 screw to S2AI screw angle was 11.3° ± 9.9°. Two violations of the iliac cortex were noted, with an average breach distance of 7.9 ± 4.8 mm. One breach was posterior (2.2%) and one was anterior (2.2%). The overall robotic S2AI screw accuracy rate was 95.7%. There were no intraoperative neurologic, vascular, or visceral complications related to the placement of the S2AI screws. Spinopelvic fixation achieved using a bone-mounted miniature robotic-guided S2AI screw insertion technique is safe and reliable. Despite two breaches, no complications related to the placement of the S2AI screws occurred in this series. Level IV, therapeutic. Copyright © 2017 Scoliosis Research Society. Published by Elsevier

  17. Development and Testing of X-Ray Imaging-Enhanced Poly-L-Lactide Bone Screws.

    Directory of Open Access Journals (Sweden)

    Wei-Jen Chang

    Full Text Available Nanosized iron oxide particles exhibit osteogenic and radiopaque properties. Thus, iron oxide (Fe3O4 nanoparticles were incorporated into a biodegradable polymer (poly-L-lactic acid, PLLA to fabricate a composite bone screw. This multifunctional, 3D printable bone screw was detectable on X-ray examination. In this study, mechanical tests including three-point bending and ultimate tensile strength were conducted to evaluate the optimal ratio of iron oxide nanoparticles in the PLLA composite. Both injection molding and 3D printing techniques were used to fabricate the PLLA bone screws with and without the iron oxide nanoparticles. The fabricated screws were implanted into the femoral condyles of New Zealand White rabbits. Bone blocks containing the PLLA screws were resected 2 and 4 weeks after surgery. Histologic examination of the surrounding bone and the radiopacity of the iron-oxide-containing PLLA screws were evaluated. Our results indicated that addition of iron oxide nanoparticles at 30% significantly decreased the ultimate tensile stress properties of the PLLA screws. The screws with 20% iron oxide exhibited strong radiopacity compared to the screws fabricated without the iron oxide nanoparticles. Four weeks after surgery, the average bone volume of the iron oxide PLLA composite screws was significantly greater than that of PLLA screws without iron oxide. These findings suggested that biodegradable and X-ray detectable PLLA bone screws can be produced by incorporation of 20% iron oxide nanoparticles. Furthermore, these screws had significantly greater osteogenic capability than the PLLA screws without iron oxide.

  18. Biomechanical properties of a novel biodegradable magnesium-based interference screw

    Directory of Open Access Journals (Sweden)

    Marco Ezechieli

    2016-06-01

    Full Text Available Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57. Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P>0.05. Stiffness was 121.1±13.8 N/mm for the magnesiumbased screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32. MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future.

  19. Cumulative occupational lumbar load and lumbar disc disease – results of a German multi-center case-control study (EPILIFT

    Directory of Open Access Journals (Sweden)

    Michaelis Martina

    2009-05-01

    Full Text Available Abstract Background The to date evidence for a dose-response relationship between physical workload and the development of lumbar disc diseases is limited. We therefore investigated the possible etiologic relevance of cumulative occupational lumbar load to lumbar disc diseases in a multi-center case-control study. Methods In four study regions in Germany (Frankfurt/Main, Freiburg, Halle/Saale, Regensburg, patients seeking medical care for pain associated with clinically and radiologically verified lumbar disc herniation (286 males, 278 females or symptomatic lumbar disc narrowing (145 males, 206 females were prospectively recruited. Population control subjects (453 males and 448 females were drawn from the regional population registers. Cases and control subjects were between 25 and 70 years of age. In a structured personal interview, a complete occupational history was elicited to identify subjects with certain minimum workloads. On the basis of job task-specific supplementary surveys performed by technical experts, the situational lumbar load represented by the compressive force at the lumbosacral disc was determined via biomechanical model calculations for any working situation with object handling and load-intensive postures during the total working life. For this analysis, all manual handling of objects of about 5 kilograms or more and postures with trunk inclination of 20 degrees or more are included in the calculation of cumulative lumbar load. Confounder selection was based on biologic plausibility and on the change-in-estimate criterion. Odds ratios (OR and 95% confidence intervals (CI were calculated separately for men and women using unconditional logistic regression analysis, adjusted for age, region, and unemployment as major life event (in males or psychosocial strain at work (in females, respectively. To further elucidate the contribution of past physical workload to the development of lumbar disc diseases, we performed lag

  20. Reproduction of the lumbar lordosis

    DEFF Research Database (Denmark)

    Andreasen, Marianne Løgtholt; Langhoff, Lotte; Jensen, Tue Secher

    2007-01-01

    OBJECTIVE: This study investigates whether it is possible to reproduce the lumbar lordosis in the upright position during magnetic resonance imaging (MRI) by positioning the patient supine with straightened lower extremities and investigates intra- and interexaminer reliability of measurements...... of the lumbar lordosis on radiographs and MRI. METHODS: This was an observational study, which included an intra- and interexaminer reliability study. The lumbar lordosis was measured digitally on radiographs taken from 22 patients in an upright standing position, and 22 MRI scans of the same patients lying...... supine with straightened lower extremities. These measurements were compared statistically. Intra- and interexaminer reliability was calculated applying the Bland and Altman method. RESULTS: The lumbar lordosis in the standing position was reproduced in the straightened supine position with a median...

  1. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    Science.gov (United States)

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Electromagnetic Lead Screw for Potential Wave Energy Application

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Wu, Weimin

    2014-01-01

    This paper presents a new type electromagnetic lead screw (EMLS) intended for wave energy application. Similar to the mechanical lead screw, this electromagnetic version can transfer slow linear motion to high-rotational motion, offering gearing effects. Compared with the existing pure magnetic...

  3. Characterization and Predictive Value of Segmental Curve Flexibility in Adolescent Idiopathic Scoliosis Patients

    DEFF Research Database (Denmark)

    Yao, Guanfeng; Cheung, Jason P Y; Shigematsu, Hideki

    2017-01-01

    STUDY DESIGN: A prospective radiographic analysis of adolescent idiopathic scoliosis (AIS) patients managed with alternate-level pedicle screw fixation was performed. OBJECTIVE: The objective of this study was to characterize segmental curve flexibility and to determine its predictive value...

  4. Bioresorbable screws reinforced with phosphate glass fibre: manufacturing and mechanical property characterisation.

    Science.gov (United States)

    Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D

    2013-01-01

    Use of bioresorbable screws could eliminate disadvantages associated with metals such as removal operations, corrosion, MRI interference and stress shielding. Mechanical properties of bioresorbable polymers alone are insufficient for load bearing applications application as screws. Thus, reinforcement is necessary to try and match or surpass the mechanical properties of cortical bone. Phosphate based glass fibres were used to reinforce polylactic acid (PLA) in order to produce unidirectionally aligned (UD) and unidirectionally plus randomly distributed (UD/RM) composite screws (P40 UD and P40 UD/RM). The maximum flexural and push-out properties for the composite screws (P40 UD and P40 UD/RM) increased by almost 100% in comparison with the PLA screws. While the pull-out strength and stiffness of the headless composite screws were ∼80% (strength) and ∼130% (stiffness) higher than for PLA, those with heads exhibited properties lower than those for PLA alone as a result of failure at the heads. An increase in the maximum shear load and stiffness for the composite screws (∼30% and ∼40%) in comparison to the PLA screws was also seen. Maximum torque for the PLA screws was ∼1000 mN m, while that for the composite screws were slightly lower. The SEM micrographs for P40 UD and P40 UD/RM screws revealed small gaps around the fibres, which were suggested to be due to buckling of the UD fibres during the manufacturing process. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Misdiagnosing absent pedicle of cervical spine in the acute trauma setting

    Directory of Open Access Journals (Sweden)

    Fahad H. Abduljabbar

    2015-09-01

    Full Text Available Congenital absence of cervical spine pedicle can be easily misdiagnosed as facet dislocation on plain radiographs especially in the acute trauma setting. Additional imaging, including computed tomography (CT-scan with careful interpretation is required in order to not misdiagnose cervical posterior arch malformation with subsequent inappropriate management. A 39-year-old patient presented to the emergency unit of our university hospital after being trampled by a cow over her back and head followed by loss of consciousness, retrograde amnesia and neck pain. Her initial cervical CT-scan showed possible C5-C6 dislocation, then, it became clear that her problem was a misdiagnosed congenital cervical abnormality. Patient was treated symptomatically without consequences. The congenital absence of a cervical pedicle is a very unusual condition that is easily misdiagnosed. Diagnosis can be accurately confirmed with a CT-scan of the cervical spine. Symptomatic conservative treatment will result in resolution of the symptoms.

  6. Nursing care for patients receiving percutaneous lumbar discectomy and intradiscal electrothermal treatment for lumbar disc herniation

    International Nuclear Information System (INIS)

    Mou Ling

    2009-01-01

    Objective: To summarize the nursing experience in caring patients with lumbar intervertebral disc herniation who received percutaneous lumbar discectomy (PLD) together with intradiscal electrothermal treatment (IDET) under DSA guidance. Methods: The perioperative nursing care measures carried out in 126 patients with lumbar intervertebral disc herniation who underwent PLD and IDET were retrospectively analyzed. Results: Successful treatment of PLD and IDET was accomplished in 112 cases. Under comprehensive and scientific nursing care and observation, no serious complications occurred. Conclusion: Scientific and proper nursing care is a strong guarantee for a successful surgery and a better recovery in treating lumbar intervertebral disc herniation with PLD and IDET under DSA guidance. (authors)

  7. A great number of old vertebral fractures expressing instability are pedicle fractures. With the use of 64-line multi slice computerized tomography

    International Nuclear Information System (INIS)

    Kobayashi, Akihiko; Nishida, Kenki; Ogawa, Koichi; Takahashi, Yuichi; Nakahara, Masayuki; Hijikata, Yasukazu

    2008-01-01

    We examined old vertebral fractures expressing instability with the use of 64-line CT. From April 2006 to December 2006, CT photographic images of 15 unstable fractures were examined in detail. We confirmed gas or liquid in all vertebral bodies. In 5 cases (33%), vertebral body protruding into the canal was observed. Four cases (23%) had other vertebral fractures. In addition, 12 pedicle fractures (73%) were seen. We confirmed many pedicle fractures in vertebral fractures expressing instability. These results suggest that pedicle fracture is a risk factor for back pain associated with vertebral fracture. (author)

  8. Lumbar spine degenerative disease : effect on bone mineral density measurements in the lumbar spine and femoral neck

    International Nuclear Information System (INIS)

    Juhng, Seon Kwan; Koplyay, Peter; Jeffrey Carr, J.; Lenchik, Leon

    2001-01-01

    To determine the effect of degenerative disease of the lumbar spine on bone mineral density in the lumbar spine and femoral neck. We reviewed radiographs and dual energy x-ray absorptiometry scans of the lumbar spine and hip in 305 Caucasian women with suspected osteoporosis. One hundred and eight-six patient remained after excluding women less than 40 years of age (n=18) and those with hip osteoarthritis, scoliosis, lumbar spine fractures, lumbar spinal instrumentation, hip arthroplasty, metabolic bone disease other than osteoporosis, or medications known to influence bone metabolism (n=101). On the basis of lumbar spine radiographs, those with absent/mild degenerative disease were assigned to the control group and those with moderate/severe degenerative disease to the degenerative group. Spine radiographs were evaluated for degenerative disease by two radiologists working independently; discrepant evaluations were resolved by consensus. Lumbar spine and femoral neck bone mineral density was compared between the two groups. Forty-five (24%) of 186 women were assigned to the degenerative group and 141 (76%) to the control group. IN the degenerative group, mean bone mineral density measured 1.075g/cm? in the spine and 0.788g/cm 2 in the femoral neck, while for controls the corresponding figures were 0.989g/cm 2 and 0.765g/cm 2 . Adjusted for age, weight and height by means of analysis of variance, degenerative disease of the lumbar spine was a significant predictor of increased bone mineral density in the spine (p=0.0001) and femoral neck (p=0.0287). Our results indicate a positive relationship between degenerative disease of the lumbar spine and bone mineral density in the lumbar spine and femoral neck, and suggest that degenerative disease in that region, which leads to an intrinsic increase in bone mineral density in the femoral neck, may be a good negative predictor of osteoporotic hip fractures

  9. Parafuso pedicular: método para correção da deformidade na escoliose idiopática do adolescente Tornillo pedicular: método para corregir la deformidad en la escoliosis idiopática del adolescente Pedicular screw: method to correct the deformity in adolescent idiopatic scoliosis

    Directory of Open Access Journals (Sweden)

    Raphael de Rezende Pratali

    2010-09-01

    translation y la rotación vertebral apical (AVR, del inglés apical vertebral rotation. El porcentaje de corrección postoperatoria fue analizado con el "índice de corrección de Cincinnati" (CPI. RESULTADOS: se observó una corrección significativa en el ángulo de Cobb en las curvas de mayor (pOBJECTIVE: to evaluate retrospectively the power of scoliotic deformity in patients that were submitted to surgical treatment with third generation instrumentation using exclusively pedicle screws in both thoracic and lumbar curves. METHODS: seventeen patients with adolescent idiopathic scoliosis (AIS were submitted to surgical treatment with deformity correction and fusion by posterior approach with pedicle screws in all vertebral bodies. Sex, age, Risser line and Lenke system of classification were analyzed. The curves were compared between pre and postoperatory in relation to Cobb angle, curve flexibility by the bending radiographs, apical vertebral translation (AVT and apical vertebral rotation (AVR. The postoperative correction percentage was expressed by the Cincinnati correction index (CCI. RESULTS: the Cobb angle had significant correction in the major curves (p<0.0001 and the minor curves (p<0.0001. The CCI of the major curves (2.89 and minor curves (1.21 differ significantly from zero (p=0.0143 and p<0.0001, respectively. The AVT had significant correction in the major curves (p=0007, but not significant in the minor curves (p=1.082. The AVR was significantly corrected in both major (p=0.0001 and minor (p=0.0033 curves. CONCLUSION: the surgery treatment of AIS with posterior fusion using third generation instrumentation has proved to be powerful in correcting the deformities besides shown to be a safe technique.

  10. Process and apparatus for optimizing screwing position for closure stud

    International Nuclear Information System (INIS)

    Bourdonne, J.C.; Briand, A.

    1987-01-01

    The stud is fixed to a screwing and unscrewing device. The vertical position and alignment of the stud with the axis of the threated hole is checking. The stud is descended into the hole and rotated in the unscrewing direction. After detection of the point of engagement, the stud is rotated in the screwing direction. When a gamming is detected the descent is stopped and the screwing device is positioned in a new position. When the screwing couple returns below the disconnection couple, the stud is rotated with a reduced speed and then with a normal speed until the end [fr

  11. Grid deformation strategies for CFD analysis of screw compressors

    OpenAIRE

    Rane, S.; Kovacevic, A.; Stosic, N.; Kethidi, M.

    2013-01-01

    Customized grid generation of twin screw machines for CFD analysis is widely used by the refrigeration and air-conditioning industry today, but is currently not suitable for topologies such as those of single screw, variable pitch or tri screw rotors. This paper investigates a technique called key-frame re-meshing that supplies pre-generated unstructured grids to the CFD solver at different time steps. To evaluate its accuracy, the results of an isentropic compression-expansion process in a r...

  12. [Stability of ventral, dorsal and combined spondylodesis in vertebral body prosthesis implantation].

    Science.gov (United States)

    Vahldiek, M; Gossè, F; Panjabi, M M

    2002-05-01

    The purpose of this study was to evaluate the biomechanical characteristics of short-segment anterior, posterior, and combined instrumentations in lumbar spine vertebral body replacement surgery. Eight fresh frozen human cadaveric thoracolumbar spine specimens (T12-L4) were prepared for biomechanical testing. Pure moments (2.5, 5, and 7.5 Nm) of flexion-extension, left-right axial torsion, and left-right lateral bending were applied to the top vertebra in a flexibility machine and the motions of L1 vertebra with respect to L3 were recorded with an optoelectronic motion measurement system after preconditioning. One anterior, two posterior pedicle screw systems, and two combined instrumentations were tested. Load-displacement curves were recorded and neutral zone (NZ) and range of motion (ROM) were determined. The anterior instrumentation, after vertebral body replacement, showed greater motion than the intact spine, especially in axial torsion. Posterior instrumentation provided greater rigidity than the anterior instrumentation, especially in flexion-extension. The combined instrumentation provided superior rigidity in all directions compared to all other instrumentations.

  13. Locking screw apparatus and method for underwater remote replacement

    International Nuclear Information System (INIS)

    Balog, L.J.

    1987-01-01

    A method is described for locking in place a screw which secures together first and second structures in the internal region of a nuclear reactor core. The first structure has a screw bore with a counterbore portion formed in an outer surface. The method comprises the steps of: forming a lateral recess in the counterbore portion and spaced from the outer surface, providing an elongated screw having an enlarged shoulder flange and an angular drive head with a lateral width substantially less than that of the counterbore portion, disposing the screw through the screw bore in threaded engagement with the second structure and with the shoulder rotatably seated in the counterbore portion. This provides a locking member having an angular opening and disposing it in the counterbore portion against the flange with the drive head received in the opening for engagement with the locking member to prevent rotation. This deforms a portion of the locking member into the recess for engagement to prevent movement of the locking member with respect to the first structure

  14. Tests for the dynamic behavior of insulation valve screws

    International Nuclear Information System (INIS)

    Tulke, K.D.; Stoppler, W.; Stern, G.

    1994-01-01

    Thermal tensile tests were performed at a temperature of 270 C, with two new original insulation valve conical screws M30-Tx92,5 mm (material: 21 CrMo V 5 7)and two prestrained ones during the event on 27.12.92. In order to assure the results obtained with regard to the dynamic load on the insulation valve during ''quick opening'', in addition tensile impact tests were performed at 270 C with six original insulation valve conical screws. Impact velocity reached 13,5 m/s at four screws and 6 m/s at two screws. Test conditions regarding collision damping and mass distribution were adapted, by means of parameter studies, to the situation of the insulation valve. During thermal tensile tests, strength and deformation values, such as stress at flow start, tensile strength, fracture prolongation and strain, necking at fracture as well as energy absorption up to maximum force and up to rupture, were determined. During tensile impact tests, deformation values, such as elongation, strain and necking, and energy absorption by the screw, were determined. (orig.) [de

  15. CT study of vertebral metastasis: re-realization of the diagnostic role of the vertebral pedicle sign

    International Nuclear Information System (INIS)

    Meng Quanfei; Jiang Bo; Chen Yingming; Zhang Chaohui

    2000-01-01

    Objective: To investigate the essence of the vertebral pedicle sign of vertebral metastasis on plain film, and to explore the useful CT signs for the diagnosis and differential diagnosis of this tumor. Methods: The CT scans of the spine obtained in 48 patients with vertebral metastases, 19 patients with vertebral tuberculosis, and 11 with vertebral myeloma, were analyzed. The CT findings were correlated with the abnormalities seen on plain films in 34 of the 48 patients (66 vertebrae involved) with vertebral metastasis. Results: 66 vertebrae were involved in the group of metastasis. Of the 28 vertebrae whose vertebral body were completely destroyed, 15 were seen bilateral pedicles destruction; Of the 22 vertebrae with lateral destruction of the body, 16 were noticed unilateral pedicle destruction which located posterior to the involved side of the body. Of the 62 micro-metastatic foci, 56 were scattered in the vertebral body. In the 19 para-spinal soft-tissue masses of vertebral tuberculosis, 5 were noticed calcifications and 12 with postcontrast rings enhancement. The rates of vertebral pedicle destruction of vertebral metastasis and myeloma were not statistically different (X 2 = 0.03, P > 0.50). The locations of destruction of vertebral body in vertebral metastasis and myeloma had no statistical difference (X 2 = 3.52, P > 0.10), but they differed from that in tuberculosis (X 2 = 39.32, P < 0.001). The distribution of lesions within the vertebrae of metastasis and tuberculosis was similar, but was quite different from myeloma. Conclusion: The vertebral metastasis initially occurs in the vertebral body. The vertebral pedicle sign on plain film of vertebral metastasis is the outcome of the posterior invasion of the tumor in the vertebral body, which is of no differential significance for vertebral metastasis and myeloma. Para-spinal soft tissue mass, location of destruction of vertebral body, and the distribution of lesions within the vertebrae may help

  16. [Longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo type IV].

    Science.gov (United States)

    Zeng, Li; Shan, Wei; Yuan, Miao; Huang, Guizhen; Huang, Lugang

    2012-11-01

    To investigate the effectiveness of longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo IV type. Between June 1994 and October 2011, 30 patients with chordee (Donnahoo type IV) underwent longitudinal preputial pedicled flap urethroplasty. The patients' age ranged from 2 to 16 years (mean, 5.8 years). The morphology of the balanus-navicular fossa-external urethral orifice ranged normal; the penis length was 2.5-6.8 cm (mean, 4.3 cm); the penis bending angle was 35-70 degrees (mean, 40.1 degrees). Primary and secondary operation was 27 cases and 3 cases, respectively. The size of flap ranged from 1.5 cm x 1.3 cm to 4.0 cm x 2.0 cm. After correction, the penis length was 3.0-8.5 cm (mean, 6.6 cm); the penis bending angle was 0-10 degrees (mean, 1.2 degrees). All patients were followed up 6 months to 12 years (mean, 33 months). No recurrence, stabbing pain of the balanus, or foreign body sensation occurred during follow-up. Of them, 4 patients (13.33%) had urinary fistular, they had satisfactory results after the second operation; 2 patients (6.67%) had urethral stricture 1 month after operation, they also had satisfactory results after arethral dilatation. The other patients showed no scattering urinary flow and good direction without complication. Six patients had satisfactory sexual function after puberty without erection disorder, pain, or dyspareunia. Longitudinal preputial pedicled flap urethroplasty can achieve maximum utilization of prepuce and aesthetic and functional improvement with less complication, so it is a relatively ideal mean for treating chordee of Donnahoo type IV.

  17. The improvement of screw compressor performance using a newly developed rotor profile

    International Nuclear Information System (INIS)

    Kishi, Takayuki; Nishio, Toshio; Matsui, Akira; Ino, Nobumi

    1994-01-01

    An oil-compression phenomenon occurs at two portions of a conventional oil injected screw compressor that degrades the isothermal efficiency of the screw compressor. Hence a new screw rotor profile and lubricant have been developed in order to avoid the above oil-compression phenomena. Mycom and Fermi National Accelerator Laboratory have measured the performance of a new Mycom compound type screw compressor 2016C using the new profile rotors and the new lubricant. In the experiments, a 33% enhancement rate in the isothermal efficiency of the new screw compressor installed in Fermilab was achieved

  18. Numerical study of internal flow in twin screw extruder and its mixing performance analysis

    International Nuclear Information System (INIS)

    Kim, Nak Soo; Kim, Hong Bum; Lee, Jae Wook

    2006-01-01

    We analyzed the non-Newtonian and non-isothermal flow in the melt conveying zone in co-rotating and counter-rotating screw extruder system with the commercial code, STAR-CD, and compared the mixing performance with respect to screw speed and rotating direction. The viscosity of fluid was described by power-law model. The dynamics of mixing was studied numerically by tracking the motion of particles in a twin screw extruder system. The extent of mixing was characterized in terms of the residence time distribution and average strain. The results showed that high screw speed decreases the residence time but increases the shear rate. Therefore higher screw speed increases the strain and has better mixing performance. Counter-rotating screw extruder system and co-rotating screw extruder has the similar shear rate with the same screw speed in spite of different rotating direction. However, the counter-rotating screw has good mixing performance, which is resulted from longer residence time than that of co-rotating screw extruder

  19. Long-term Clinical and Radiographic Outcomes of Pedicle Subtraction Osteotomy for Fixed Sagittal Imbalance: Does Level of Proximal Fusion Affect the Outcome? Minimum 5-Year Follow-up.

    Science.gov (United States)

    Yagi, Mitsuru; King, Akilah B; Cunningham, Matthew E; Boachie-Adjei, Oheneba

    2013-03-01

    Retrospective case series of surgically treated adult patients with fixed sagittal imbalance. To assess clinical and radiographic changes after pedicle subtraction osteotomy (PSO) to treat adult fixed sagittal imbalance. Although recent reports have shown favorable clinical outcomes for PSO, few reports have published long-term follow-up outcomes. It is also unknown whether long-term outcomes are correlated with the level of proximal fusion and the radiographic changes that are observed after PSO. We reviewed the charts, X-rays, and postoperative SRS-22 and Oswestry Disability Index (ODI) scores of 32 adult patients who presented with fixed sagittal imbalance and were treated with lumbar PSO. Long fusions were defined as those proximal to T6, and short fusions were defined as those below T8. Measured radiographic parameters included thoracic kyphosis, lumbar lordosis (LL), sacral slope, pelvic incidence, and sagittal balance (SVA). Statistical analysis included Student t test and chi-square test. A p value of imbalance, PSO provided good sagittal balance and maintained favorable clinical outcomes in both the short and long fusion groups despite a slight decrease in the SVA and a high complication rate. The data suggest that the loss of sagittal balance may be attributed to increase global and junctional kyphosis in short fusion groups, and should be monitored for long-term outcomes. Particular attention should be paid to the long-term deterioration of the SVA in adults who present with fixed sagittal imbalance after PSO. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  20. Comprehensive comparing percutaneous endoscopic lumbar discectomy with posterior lumbar internal fixation for treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis: A retrospective case-control study.

    Science.gov (United States)

    Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong

    2017-07-01

    The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery.In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared.The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively.PELD operation was superior in terms of operation time, bleeding volume, recovery period, and financial