WorldWideScience

Sample records for lowest detected concentration

  1. Determination of the lowest concentrations of aldehyde fixatives for completely fixing various cellular structures by real-time imaging and quantification.

    Science.gov (United States)

    Zeng, Fangfa; Yang, Wen; Huang, Jie; Chen, Yuan; Chen, Yong

    2013-05-01

    The effectiveness of fixatives for fixing biological specimens has long been widely investigated. However, the lowest concentrations of fixatives needed to completely fix whole cells or various cellular structures remain unclear. Using real-time imaging and quantification, we determined the lowest concentrations of glutaraldehyde (0.001-0.005, ~0.005, 0.01-005, 0.01-005, and 0.01-0.1 %) and formaldehyde/paraformaldehyde (0.01-0.05, ~0.05, 0.5-1, 1-1.5, and 0.5-1 %) required to completely fix focal adhesions, cell-surface particles, stress fibers, the cell cortex, and the inner structures of human umbilical vein endothelial cells within 20 min. With prolonged fixation times (>20 min), the concentration of fixative required to completely fix these structures will shift to even lower values. These data may help us understand and optimize fixation protocols and understand the potential effects of the small quantities of endogenously generated aldehydes in human cells. We also determined the lowest concentration of glutaraldehyde (0.5 %) and formaldehyde/paraformaldehyde (2 %) required to induce cell blebbing. We found that the average number and size of the fixation-induced blebs per cell were dependent on both fixative concentration and cell spread area, but were independent of temperature. These data provide important information for understanding cell blebbing, and may help optimize the vesiculation-based technique used to isolate plasma membrane by suggesting ways of controlling the number or size of fixation-induced cell blebs.

  2. Determining the 95% limit of detection for waterborne pathogen analyses from primary concentration to qPCR

    Science.gov (United States)

    Stokdyk, Joel P.; Firnstahl, Aaron; Spencer, Susan K.; Burch, Tucker R; Borchardt, Mark A.

    2016-01-01

    The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L−1 assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation.

  3. The Performance of CO2 Laser Photoacoustic Spectrometer In Concentration Acetone Detection As Biomarker For Diabetes Mellitus Type 2

    Science.gov (United States)

    Tyas, F. H.; Nikita, J. G.; Apriyanto, D. K.; Mitrayana; Amin, M. N.

    2018-04-01

    Breath analysis is useful for the diagnosis of human diseases and monitoring of metabolic status. However, because of the low concentrations and the large numbers of compounds in the breath, the breath analysis requires highly sensitive and highly selective instruments to identify and determine the concentrations of certain biomarkers [1]. Various methods developed over the past 20 years to detect biomarker gases [2]. CO2 laser photoacoustic spectroscopy offers a sensitive technique for the detection and monitoring of gas footprints at low concentrations [3]. The performance of photoacoustic spectrometer (PAS) examined with intracavity configuration. In this research, the highest observed intracavity power was (49,96 ± 0,02) W for active medium gas composition He: N2: CO2 at 30:50:50. The highest laser absorption line for standard acetone gas set at 10P20, and the lowest detection limit set at (30 ± 4) ppb. For application purposes, the photoacoustic spectrometer was used to measure the concentration of acetone gas in exhaled gases from a group of patients with type 2 diabetes mellitus and a group of healthy volunteers. Exhaled gas sampling method took manually, and the measurement result was examined using multicomponent analysis. The measurement showed that the highest acetone gas concentration for type 2 diabetes mellitus patients was (162 ± 3) × 10 ppb and the lowest one was (101 ± 3) × 10 ppb. Furthermore, for healthy volunteers, the highest acetone gas concentration was (85 ± 3) × 10 ppb and the lowest one was (15 ± 3) × 10 ppb.

  4. The advantageous way of getting the lowest uncertainty values of elemental concentration by INAA

    International Nuclear Information System (INIS)

    Cincu, Em.; Manea, I.; Manu, V.; Barbos, D.

    2007-01-01

    Analysts in a NAA accredited laboratory bear full responsibility for the report on the material they investigated. The document has to contain the most accurate values that can be, as confidence to further use of the material on the market. To this end, analysts are expected to use the standardization method providing the lowest element concentration uncertainty and carefully quantify every factor that may contribute to the validity of the results. The question is which method is the most advantageous one from this perspective and in what conditions. This paper presents a comparison between results of the elemental analysis of a CRM sample by INAA, as obtained through two standardization methods and three calculations variants applied to the same experimental data. The results were discussed in terms of uncertainty and of the E n statistical criterion recommended for inter-comparison exercises. The influence of the nuclear reaction and decay data was studied in several cases. (author)

  5. Theoretical study of the lowest-lying electronic states of Aluminium monoiodide

    International Nuclear Information System (INIS)

    Taher, F.; Kabbani, A.; Ani-El Houte, W.

    2004-01-01

    Full text.The spectroscopic study of Aluminium monohalides, especially the Aluminium monoiodide, is important for monitoring such species in high temperature fast-flow reactors. Theoretical calculations of AlI are not available, whereas several studies have been done for the other aluminium monohalides. In this work, CAS-SCF/MRCI calculations are performed for the lowest-lying electronic states of AlI in a range of internuclear distance between 2.30 A and 2.80 A. Ab-initio calculations have been effectuated by using the computational chemistry program Molpro. The basis set used in this study for aluminium atom is that used by Langhoff for aluminium monohalides, of contractions using atomic natural orbitals and a pseudopotential is used for iode. Accurate theoretical spectroscopic constants and potential curves are obtained for the ground state X 1 Σ + and the first excited states a 3 Π and A 1 Π. The calculated values of Te, ωe, ωexe and re of these states are compatible with the experimental results. An ordering of states is represented for the lowest five predicted singlet and lowest five predicted triplet states. These results provide a big support to determine the analogy in the ordering of the electronic states in AlF, AlBr and AlI respectively at lower energies. These theoretical results identify a set of electronic singlet and triplet states unobserved experimentally

  6. Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

    International Nuclear Information System (INIS)

    MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna; Haseley, David; Kelly, Mary M.; Liu, Franklin; Parikh, Jay R.; Beatty, J. David; Rogers, James V.

    2012-01-01

    Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44–4.1 kBq/mL, corresponding to 46–400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to score the presence of spheres. Results: Sensitivity was 100% for lesions ≥12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained ≥90% for injected activities as low as 100 MBq, for lesions ≥8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.

  7. Uncertainty and minimum detectable concentrations using relative, absolute and K*0-IAEA standardization for the INAA laboratory of the ETRR-2

    International Nuclear Information System (INIS)

    Khalil, M. Y.

    2006-01-01

    Full text: The Instrumental Neutron Activation Analysis (INAA) Laboratory of Egypt Second Training and Research Reactor (ETRR-2) is increasingly requested to perform multi-element analysis to large number of samples from different origins. The INAA laboratory has to demonstrate competence by conforming to appropriate internationally and nationally accepted standards. The objective of this work is to determine the uncertainty budget and sensitivity of the INAA laboratory measurements. Concentrations of 9 elements; Mn, Na, K, Ca, Co, Cr, Fe, Rb, and Cs, were measured against a certified test sample. Relative, absolute, and Ko-IAEA standardization methods were employed and results compared. The flux was monitored using cadmium covered gold method, and multifoil (gold, nickel and zirconium) method. The combined and expanded uncertainties were estimated. Uncertainty of concentrations ranged between 2-21% depending on the standardization method used. The relative method, giving the lowest uncertainty, produced uncertainty budget between 2 and 11%. The minimum detectable concentration was the lowest for Cs ranging between 0.36 and 0.59 ppb and the highest being for K in the range of 0.32 to 8.64 ppm

  8. Porous Silicon Covered with Silver Nanoparticles as Surface-Enhanced Raman Scattering (SERS) Substrate for Ultra-Low Concentration Detection.

    Science.gov (United States)

    Kosović, Marin; Balarin, Maja; Ivanda, Mile; Đerek, Vedran; Marciuš, Marijan; Ristić, Mira; Gamulin, Ozren

    2015-12-01

    Microporous and macro-mesoporous silicon templates for surface-enhanced Raman scattering (SERS) substrates were produced by anodization of low doped p-type silicon wafers. By immersion plating in AgNO3, the templates were covered with silver metallic film consisting of different silver nanostructures. Scanning electron microscopy (SEM) micrographs of these SERS substrates showed diverse morphology with significant difference in an average size and size distribution of silver nanoparticles. Ultraviolet-visible-near-infrared (UV-Vis-NIR) reflection spectroscopy showed plasmonic absorption at 398 and 469 nm, which is in accordance with the SEM findings. The activity of the SERS substrates was tested using rhodamine 6G (R6G) dye molecules and 514.5 nm laser excitation. Contrary to the microporous silicon template, the SERS substrate prepared from macro-mesoporous silicon template showed significantly broader size distribution of irregular silver nanoparticles as well as localized surface plasmon resonance closer to excitation laser wavelength. Such silver morphology has high SERS sensitivity that enables ultralow concentration detection of R6G dye molecules up to 10(-15) M. To our knowledge, this is the lowest concentration detected of R6G dye molecules on porous silicon-based SERS substrates, which might even indicate possible single molecule detection.

  9. Silica Gel Coated Spherical Micro resonator for Ultra-High Sensitivity Detection of Ammonia Gas Concentration in Air.

    Science.gov (United States)

    Mallik, Arun Kumar; Farrell, Gerald; Liu, Dejun; Kavungal, Vishnu; Wu, Qiang; Semenova, Yuliya

    2018-01-26

    A silica gel coated microsphere resonator is proposed and experimentally demonstrated for measurements of ammonia (NH 3 ) concentration in air with ultra-high sensitivity. The optical properties of the porous silica gel layer change when it is exposed to low (parts per million (ppm)) and even ultra-low (parts per billion (ppb)) concentrations of ammonia vapor, leading to a spectral shift of the WGM resonances in the transmission spectrum of the fiber taper. The experimentally demonstrated sensitivity of the proposed sensor to ammonia is estimated as 34.46 pm/ppm in the low ammonia concentrations range from 4 ppm to 30 ppm using an optical spectrum analyser (OSA), and as 800 pm/ppm in the ultra-low range of ammonia concentrations from 2.5 ppb to 12 ppb using the frequency detuning method, resulting in the lowest detection limit (by two orders of magnitude) reported to date equal to 0.16 ppb of ammonia in air. In addition, the sensor exhibits excellent selectivity to ammonia and very fast response and recovery times measured at 1.5 and 3.6 seconds, respectively. Other attractive features of the proposed sensor are its compact nature, simplicity of fabrication.

  10. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  11. Serum paraquat concentration detected by spectrophotometry in patients with paraquat poisoning

    Science.gov (United States)

    Li, Chang-bin; Li, Xin-hua; Wang, Zhen; Jiang, Cheng-hua; Peng, Ai

    2011-01-01

    BACKGROUND: Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role in prognosis. Spectrophotometry, including common spectrophotometry and second-derivative spectrophotometry, is commonly used for PQ detection in primary hospitals. So far, lack of systematic research on the reliability of the method and the correlation between clinical features of patients with PQ poisoning and the test results has restricted the clinical use of spectrophotometry. This study aimed to evaluate the reliability and value of spectrophotometry in detecting the concentration of serum PQ. METHODS: The wavelengths for detecting the concentration of serum PQ by common and second-derivative spectrophotometry were determined. Second-derivative spectrophotometry was applied to detect the concentration of serum PQ. The linear range and precision for detection of PQ concentration by this method were confirmed. The concentration of serum PQ shown by second-derivative spectrophotometry and HPLC were compared in 8 patients with PQ poisoning. Altogether 21 patients with acute poisoning 4 hours after PQ ingestion treated in the period of October 2008 to September 2010 were retrospectively reviewed. The patients were divided into higher and lower than 1.8 μg/mL groups based on their concentrations of serum PQ measured by second-derivative spectrophotometry on admission. The severity of clinical manifestations between the two groups were analyzed with Student's t test or Fisher's exact test. RESULTS: The absorption peak of 257 nm could not be found when common spectrophotometry was used to detect the PQ concentration in serum. The calibration curve in the 0.4–8.0 μg/mL range for PQ concentration shown by second-derivative spectrophotometry obeyed Beer's law with r=0.996. The average recovery rates of PQ were within a range of 95.0% to 99.5%, relative

  12. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  13. Detection of Changes in Ground-Level Ozone Concentrations via Entropy

    Directory of Open Access Journals (Sweden)

    Yuehua Wu

    2015-04-01

    Full Text Available Ground-level ozone concentration is a key indicator of air quality. Theremay exist sudden changes in ozone concentration data over a long time horizon, which may be caused by the implementation of government regulations and policies, such as establishing exhaust emission limits for on-road vehicles. To monitor and assess the efficacy of these policies, we propose a methodology for detecting changes in ground-level ozone concentrations, which consists of three major steps: data transformation, simultaneous autoregressive modelling and change-point detection on the estimated entropy. To show the effectiveness of the proposed methodology, the methodology is applied to detect changes in ground-level ozone concentration data collected in the Toronto region of Canada between June and September for the years from 1988 to 2009. The proposed methodology is also applicable to other climate data.

  14. Electromagnetic structure of the lowest-lying decuplet resonances in covariant chiral perturbation theory

    International Nuclear Information System (INIS)

    Geng, L. S.; Camalich, J. Martin; Vacas, M. J. Vicente

    2009-01-01

    We present a calculation of the leading SU(3)-breaking O(p 3 ) corrections to the electromagnetic moments and charge radius of the lowest-lying decuplet resonances in covariant chiral perturbation theory. In particular, the magnetic dipole moment of the members of the decuplet is predicted fixing the only low-energy constant (LEC) present up to this order with the well-measured magnetic dipole moment of the Ω - . We predict μ Δ ++ =6.04(13) and μ Δ + =2.84(2), which agree well with the current experimental information. For the electric quadrupole moment and the charge radius, we use state-of-the-art lattice QCD results to determine the corresponding LECs, whereas for the magnetic octupole moment there is no unknown LEC up to the order considered here, and we obtain a pure prediction. We compare our results with those reported in large N c , lattice QCD, heavy-baryon chiral perturbation theory, and other models.

  15. Determination of hydrogen peroxide in water by chemiluminescence detection, (1). Flow injection type hydrogen peroxide detection system

    International Nuclear Information System (INIS)

    Yamashiro, Naoya; Uchida, Shunsuke; Satoh, Yoshiyuki; Morishima, Yusuke; Yokoyama, Hiroaki; Satoh, Tomonori; Sugama, Junichi; Yamada, Rie

    2004-01-01

    A flow injection type hydrogen peroxide detection system with a sub-ppb detection limit has been developed to determine hydrogen peroxide concentration in water sampled from a high temperature, high pressure hydrogen peroxide water loop. The hydrogen peroxide detector is based on luminol chemiluminescence spectroscopy. A small amount of sample water (20 μl) is mixed with a reagent mixture, an aqueous solution of luminol and Co 2+ catalyst, in a mixing cell which is installed just upstream from the detection cell. The optimum values for pH and the concentrations of luminol and Co 2+ ion have been determined to ensure a lower detectable limit and a higher reproducibility. The photocurrent detected by the detection system is expressed by a linear function of the hydrogen peroxide concentration in the region of lower concentration ([H 2 O 2 ] 2 O 2 ] in the region of higher concentration ([H 2 O 2 ] > 10 ppb). The luminous intensity of luminol chemiluminescence is the highest when pH of the reagent mixture is 11.0. Optimization of the major parameters gives the lowest detectable limit of 0.3 ppb. (author)

  16. NO NEUTRON STAR COMPANION TO THE LOWEST MASS SDSS WHITE DWARF

    International Nuclear Information System (INIS)

    Agueeros, Marcel A.; Camilo, Fernando; Heinke, Craig; Kilic, Mukremin; Anderson, Scott F.; Silvestri, Nicole M.; Freire, Paulo; Kleinman, Scot J.; Liebert, James W.

    2009-01-01

    SDSS J091709.55+463821.8 (hereafter J0917+4638) is the lowest surface gravity white dwarf (WD) currently known, with log g = 5.55 ± 0.05 (M ∼ 0.17 M sun ). Such low-mass white dwarfs (LMWDs) are believed to originate in binaries that evolve into WD/WD or WD/neutron star (NS) systems. An optical search for J0917+4638's companion showed that it must be a compact object with a mass ≥0.28 M sun . Here we report on Green Bank Telescope 820 MHz and XMM-Newton X-ray observations of J0917+4638 intended to uncover a potential NS companion to the LMWD. No convincing pulsar signal is detected in our radio data. Our X-ray observation also failed to detect X-ray emission from J0917+4638's companion, while we would have detected any of the millisecond radio pulsars in 47 Tuc. We conclude that the companion is almost certainly another WD.

  17. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    Directory of Open Access Journals (Sweden)

    Qing-Hui WANG

    2014-02-01

    Full Text Available This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or concentration, the proposed detection system with lower cost and higher accuracy can be applied in the occasion which needs simultaneous monitoring of gas concentration and flow rate.

  18. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-16

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

  19. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

  20. Microfluidic acoustophoretic force based low-concentration oil separation and detection from the environment.

    Science.gov (United States)

    Wang, Han; Liu, Zhongzheng; Kim, Sungman; Koo, Chiwan; Cho, Younghak; Jang, Dong-Young; Kim, Yong-Joe; Han, Arum

    2014-03-07

    Detecting and quantifying extremely low concentrations of oil from the environment have broad applications in oil spill monitoring in ocean and coastal areas as well as in oil leakage monitoring on land. Currently available methods for low-concentration oil detection are bulky or costly with limited sensitivities. Thus they are difficult to be used as portable and field-deployable detectors in the case of oil spills or for monitoring the long-term effects of dispersed oil on marine and coastal ecosystems. Here, we present a low-concentration oil droplet trapping and detection microfluidic system based on the acoustophoresis phenomenon where oil droplets in water having a negative acoustic contrast factor move towards acoustic pressure anti-nodes. By trapping oil droplets from water samples flowing through a microfluidic channel, even very low concentrations of oil droplets can be concentrated to a detectable level for further analyses, which is a significant improvement over currently available oil detection systems. Oil droplets in water were successfully trapped and accumulated in a circular acoustophoretic trapping chamber of the microfluidic device and detected using a custom-built compact fluorescent detector based on the natural fluorescence of the trapped crude oil droplets. After the on-line detection, crude oil droplets released from the trapping chamber were successfully separated into a collection outlet by acoustophoretic force for further off-chip analyses. The developed microfluidic system provides a new way of trapping, detecting, and separating low-concentration crude oil from environmental water samples and holds promise as a low-cost field-deployable oil detector with extremely high sensitivity. The microfluidic system and operation principle are expected to be utilized in a wide range of applications where separating, concentrating, and detecting small particles having a negative acoustic contrast factor are required.

  1. Mixing of the lowest-lying qqq configurations with JP =1/2- in different hyperfine interaction models

    Science.gov (United States)

    Chen, Jia; An, Chunsheng; Chen, Hong

    2018-02-01

    We investigate mixing of the lowest-lying qqq configurations with JP = 1/2- caused by the hyperfine interactions between quarks mediated by Goldstone Boson Exchange, One Gluon Exchange, and both Goldstone Boson and One Gluon exchange, respectively. The first orbitally excited nucleon, Σ, Λ and Ξ states are considered. Contributions of both the contact term and tensor term are taken into account. Our numerical results show that mixing of the studied configurations in the two employed hyperfine interaction models are very different. Therefore, the present results, which should affect the strong and electromagnetic decays of baryon resonances, may be used to examine the present employed hyperfine interaction models. Supported by National Natural Science Foundation of China (11675131,11645002), Chongqing Natural Science Foundation (cstc2015jcyjA00032) and Fundamental Research Funds for the Central Universities (SWU115020)

  2. Millimeter-wave and Submillimeter-wave Spectra of Aminoacetonitrile in the Three Lowest Vibrational Excited States

    Energy Technology Data Exchange (ETDEWEB)

    Esposti, Claudio Degli; Dore, Luca; Melosso, Mattia [Dipartimento di Chimica “Giacomo Ciamician”, Università di Bologna, via Selmi 2, I-40126 Bologna (Italy); Kobayashi, Kaori [Department of Physics, Faculty of Science, University of Toyama, 3190 Gofuku, Toyama 930-8555 (Japan); Fujita, Chiho; Ozeki, Hiroyuki, E-mail: ozeki@env.sci.toho-u.ac.jp [Department of Environmental Science, Faculty of Science, Toho University, 2-2-1 Miyama, Funabashi, 274-8510 (Japan)

    2017-06-01

    It is important to study possible precursors of amino acids such as glycine to enable future searches in interstellar space. Aminoacetonitrile (NH{sub 2}CH{sub 2}CN) is one of the most feasible molecules for this purpose. This molecule was already detected toward Sgr B2(N). Aminoacetonitrile has a few low-lying vibrational excited states, and transitions within these states may be found in space. In this study, the pure-rotational transitions in the three lowest vibrational states in the 80–450 GHz range have been assigned and analyzed. It was found to be very important to include Coriolis coupling between the two lowest vibrational fundamentals, while the third one was unperturbed. The partition function was evaluated considering these new results.

  3. Alumina Concentration Detection Based on the Kernel Extreme Learning Machine.

    Science.gov (United States)

    Zhang, Sen; Zhang, Tao; Yin, Yixin; Xiao, Wendong

    2017-09-01

    The concentration of alumina in the electrolyte is of great significance during the production of aluminum. The amount of the alumina concentration may lead to unbalanced material distribution and low production efficiency and affect the stability of the aluminum reduction cell and current efficiency. The existing methods cannot meet the needs for online measurement because industrial aluminum electrolysis has the characteristics of high temperature, strong magnetic field, coupled parameters, and high nonlinearity. Currently, there are no sensors or equipment that can detect the alumina concentration on line. Most companies acquire the alumina concentration from the electrolyte samples which are analyzed through an X-ray fluorescence spectrometer. To solve the problem, the paper proposes a soft sensing model based on a kernel extreme learning machine algorithm that takes the kernel function into the extreme learning machine. K-fold cross validation is used to estimate the generalization error. The proposed soft sensing algorithm can detect alumina concentration by the electrical signals such as voltages and currents of the anode rods. The predicted results show that the proposed approach can give more accurate estimations of alumina concentration with faster learning speed compared with the other methods such as the basic ELM, BP, and SVM.

  4. Giant angular resonance and the structure of the lowest-lying nuclear states

    International Nuclear Information System (INIS)

    Mikhajlov, I.N.; Usmanov, P.N.; Yuldashbaeva, Eh.Kh.

    1987-01-01

    The analysis is given of the Hamiltonian of the two-rotor model, which is based on the assumption that the giant angular resonance exists, i.e. that it is possible to rotate the neutron component of a deformed nucleus as a whole with respect to the proton component. The realization of the projections on the intrinsic axes of the angular momentum operators is found, the Hamiltonian matrix is determined in the basis convenient for the case of strong neutron-proton coupling. The spectrum of the two-rotor model is determined taking into account the nondiagonal matrix elements in the lowest order of the perturbation theory. The g factors and the probabilities of the M1 transitions are discussed

  5. Lowest order Virtual Element approximation of magnetostatic problems

    Science.gov (United States)

    Beirão da Veiga, L.; Brezzi, F.; Dassi, F.; Marini, L. D.; Russo, A.

    2018-04-01

    We give here a simplified presentation of the lowest order Serendipity Virtual Element method, and show its use for the numerical solution of linear magneto-static problems in three dimensions. The method can be applied to very general decompositions of the computational domain (as is natural for Virtual Element Methods) and uses as unknowns the (constant) tangential component of the magnetic field $\\mathbf{H}$ on each edge, and the vertex values of the Lagrange multiplier $p$ (used to enforce the solenoidality of the magnetic induction $\\mathbf{B}=\\mu\\mathbf{H}$). In this respect the method can be seen as the natural generalization of the lowest order Edge Finite Element Method (the so-called "first kind N\\'ed\\'elec" elements) to polyhedra of almost arbitrary shape, and as we show on some numerical examples it exhibits very good accuracy (for being a lowest order element) and excellent robustness with respect to distortions.

  6. Comparison of concentrations of mercury in ambient air to its accumulation by leafy vegetables: An important step in terrestrial food chain analysis

    Energy Technology Data Exchange (ETDEWEB)

    Temmerman, Ludwig de [Veterinary and Agrochemical Research Centre, Leuvensesteenweg 17, B-3080 Tervuren (Belgium)], E-mail: ludet@var.fgov.be; Waegeneers, Nadia [Veterinary and Agrochemical Research Centre, Leuvensesteenweg 17, B-3080 Tervuren (Belgium); Claeys, Natacha; Roekens, Edward [Vlaamse Milieumaatschappij, Afdeling Lucht, Milieu en Communicatie, Kronenburgstraat 45, bus3, B-2000 Antwerpen (Belgium)

    2009-04-15

    A biomonitoring network with leafy vegetables was established near a chlor-alkali plant in order to compare the accumulation of mercury to the atmospheric total gaseous mercury (TGM) concentration. Based on data obtained in the reference area the 'normal' mercury concentration in vegetables is between 0.6 and 5.4 {mu}g kg{sup -1} FW. The effect detection limits (EDLs) are between 1.2 and 11.0 {mu}g kg{sup -1} FW and the biological detection limits (BDLs), the lowest [TGM] that can be detected significantly, are between 3 and 4 ng m{sup -3}. The accumulation rate is lowest for lettuce and high for curly kale that proved to be an excellent accumulator and as such it is very useful for biomonitoring purposes. A comparison made in the 1980s between biomonitoring results with grass and the mercury concentration in leafy vegetables from private gardens nearby proved to be valid when applied to the current biomonitoring results with vegetables. - Leafy vegetables are an important component in the transfer of atmospheric mercury through the terrestrial food chain.

  7. Comparison of concentrations of mercury in ambient air to its accumulation by leafy vegetables: An important step in terrestrial food chain analysis

    International Nuclear Information System (INIS)

    Temmerman, Ludwig de; Waegeneers, Nadia; Claeys, Natacha; Roekens, Edward

    2009-01-01

    A biomonitoring network with leafy vegetables was established near a chlor-alkali plant in order to compare the accumulation of mercury to the atmospheric total gaseous mercury (TGM) concentration. Based on data obtained in the reference area the 'normal' mercury concentration in vegetables is between 0.6 and 5.4 μg kg -1 FW. The effect detection limits (EDLs) are between 1.2 and 11.0 μg kg -1 FW and the biological detection limits (BDLs), the lowest [TGM] that can be detected significantly, are between 3 and 4 ng m -3 . The accumulation rate is lowest for lettuce and high for curly kale that proved to be an excellent accumulator and as such it is very useful for biomonitoring purposes. A comparison made in the 1980s between biomonitoring results with grass and the mercury concentration in leafy vegetables from private gardens nearby proved to be valid when applied to the current biomonitoring results with vegetables. - Leafy vegetables are an important component in the transfer of atmospheric mercury through the terrestrial food chain

  8. Concentrations of Nicotinamide in Plasma by RP-HPLC With Fluorescence Detection

    Directory of Open Access Journals (Sweden)

    Pan Zhipeng

    2016-01-01

    Full Text Available The purpose of this study is to establish a new method for detecting nicotinamide concentration in plasma. In the experiment, the high performance liquid chromatography (HPLC method was used, with a fluorescence detector. The nicotinamide in the plasma was first converted to N1- methylnicotinamide, then reacted with acetophenone under certain conditions to produce fluorescent derivatives for testing. The method is a kind of highly sensitive detection, of which the lower limit is 10 ng/mL, the recovery rate is between 92.75% and 105.13%, and the relative standard deviation (RSD is between 3.76% and 4.43%. The results showed that this measurement method is accurate, sensitive and rapid. It meets the requirements of the experiment, and applies to the detection of nicotinamide concentration in plasma.

  9. Automatic Echographic Detection of Halloysite Clay Nanotubes in a Low Concentration Range.

    Science.gov (United States)

    Conversano, Francesco; Pisani, Paola; Casciaro, Ernesto; Di Paola, Marco; Leporatti, Stefano; Franchini, Roberto; Quarta, Alessandra; Gigli, Giuseppe; Casciaro, Sergio

    2016-04-11

    Aim of this work was to investigate the automatic echographic detection of an experimental drug delivery agent, halloysite clay nanotubes (HNTs), by employing an innovative method based on advanced spectral analysis of the corresponding "raw" radiofrequency backscatter signals. Different HNT concentrations in a low range (5.5-66 × 10 10 part/mL, equivalent to 0.25-3.00 mg/mL) were dispersed in custom-designed tissue-mimicking phantoms and imaged through a clinically-available echographic device at a conventional ultrasound diagnostic frequency (10 MHz). The most effective response (sensitivity = 60%, specificity = 95%), was found at a concentration of 33 × 10 10 part/mL (1.5 mg/mL), representing a kind of best compromise between the need of enough particles to introduce detectable spectral modifications in the backscattered signal and the necessity to avoid the losses of spectral peculiarity associated to higher HNT concentrations. Based on theoretical considerations and quantitative comparisons with literature-available results, this concentration could also represent an optimal concentration level for the automatic echographic detection of different solid nanoparticles when employing a similar ultrasound frequency. Future dedicated studies will assess the actual clinical usefulness of the proposed approach and the potential of HNTs for effective theranostic applications.

  10. Detection of atmospheric tritium by scintillation. Variations in its concentration in France; Detection du tritium atmospherique par scintillation. Evolution de sa concentration en France

    Energy Technology Data Exchange (ETDEWEB)

    Bibron, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    The tritium released into the atmosphere as a result of the explosion of thermonuclear devices is a useful radioactive tracer for the study of certain geophysical problems. The low concentrations found however call for the use of extremely sensitive detectors. Two detection methods using liquid scintillators are described. In the first method, the sample is introduced into the scintillator in liquid form, after prior concentration of the tritium by electrolysis. In the second method the tritium is incorporated into the scintillator solvent molecule by chemical synthesis. In the last part of the report are examined the variations in the tritium concentration in rain-water and of the free hydrogen in the air in France. A discussion is then made of the seasonal variations in the case of rain-water and these are compared to the variations in the strontium-90 concentrations. (author) [French] Le tritium introduit dans l'atmosphere par les explosions d'armes thermonucleaires est un traceur radioactif Interessant pour l'etude de certains problemes de geophysique. Les faibles concentrations rencontrees obligent toutefois a utiliser des detecteurs extremement sensibles. On decrit deux methodes de detection utilisant des scintillateurs liquides. Dans la premiere methode, l'echantillon est introduit dans le scintillateur, sous forme aqueuse, apres une concentration prealable du tritium par electrolyse. Dans la seconde methode, le tritium est incorpore a la molecule du solvant du scintillateur par synthese chimique. Dans la derniere partie du rapport, on examine l'evolution de la concentration du tritium dans les eaux de precipitation et l'hydrogene libre de l'air en France. On discute ensuite les variations saisonnieres dans le cas des eaux de precipitation et on les compare aux variations du strontium 90. (auteur)

  11. Detection of atmospheric tritium by scintillation. Variations in its concentration in France; Detection du tritium atmospherique par scintillation. Evolution de sa concentration en France

    Energy Technology Data Exchange (ETDEWEB)

    Bibron, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    The tritium released into the atmosphere as a result of the explosion of thermonuclear devices is a useful radioactive tracer for the study of certain geophysical problems. The low concentrations found however call for the use of extremely sensitive detectors. Two detection methods using liquid scintillators are described. In the first method, the sample is introduced into the scintillator in liquid form, after prior concentration of the tritium by electrolysis. In the second method the tritium is incorporated into the scintillator solvent molecule by chemical synthesis. In the last part of the report are examined the variations in the tritium concentration in rain-water and of the free hydrogen in the air in France. A discussion is then made of the seasonal variations in the case of rain-water and these are compared to the variations in the strontium-90 concentrations. (author) [French] Le tritium introduit dans l'atmosphere par les explosions d'armes thermonucleaires est un traceur radioactif Interessant pour l'etude de certains problemes de geophysique. Les faibles concentrations rencontrees obligent toutefois a utiliser des detecteurs extremement sensibles. On decrit deux methodes de detection utilisant des scintillateurs liquides. Dans la premiere methode, l'echantillon est introduit dans le scintillateur, sous forme aqueuse, apres une concentration prealable du tritium par electrolyse. Dans la seconde methode, le tritium est incorpore a la molecule du solvant du scintillateur par synthese chimique. Dans la derniere partie du rapport, on examine l'evolution de la concentration du tritium dans les eaux de precipitation et l'hydrogene libre de l'air en France. On discute ensuite les variations saisonnieres dans le cas des eaux de precipitation et on les compare aux variations du strontium 90. (auteur)

  12. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  13. Concentration and detection of hepatitis A virus and its indicator from artificial seawater using zeolite.

    Science.gov (United States)

    Cormier, Jiemin; Janes, Marlene

    2016-09-01

    Hepatitis A virus (HAV) infection is the leading worldwide cause of acute viral hepatitis, and outbreaks caused by this virus often occur in fecal polluted waters. Rapid concentration and detection of viral contamination in water environments can prevent economic loss and can identify the source of contamination within a short time. However, conventional methods for virus concentration are often laborious, time consuming, and subject to clogging. Furthermore, most methods require a secondary concentration step to reduce the final volume of samples. We developed a method to concentrate HAV from seawater using zeolite in aid of rapid detection. In this method,artificial seawater was inoculated with HAV (7-8 log TCID50) and filtered with zeolite. The viruses were then eluted from zeolite with sodium dodecyl sulfate and detected via real-time PCR (qPCR). Zeolite was able to concentrate HAV from artificial seawater with ∼99% efficiency in less than 5min and was more efficient in seawater than in fresh water. The entire concentration and detection can be done in approximately 2h. Compared to existing methods, this method eliminated the need for a secondary concentration step as well as the necessity to modify the pH or salinity of the seawater during concentration, and was simple and inexpensive. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Europe the continent with the lowest fertility

    NARCIS (Netherlands)

    Baird, D. T.; Collins, J.; Evers, J. L. H.; Leridon, H.; Lutz, W.; Velde, E. Te; Thevenon, O.; Crosignani, P. G.; Devroey, P.; Diedrich, K.; Fauser, B. C. J. M.; Fraser, L.; Geraedts, J. P. M.; Gianaroli, L.; Glasier, A.; Sunde, A.; Tarlatzis, B.; Van Steirteghem, A.; Veiga, A.

    2010-01-01

    INTRODUCTION: Although fertility rates are falling in many countries, Europe is the continent with the lowest total fertility rate (TFR). This review assesses trends in fertility rates, explores possible health and social factors and reviews the impact of health and social interventions designed to

  15. Bacterial concentration detection using a portable embedded sensor system for environmental monitoring

    OpenAIRE

    Grossi , Marco; Riccò , Bruno; Parolin , Carola; Vitali , Beatrice

    2017-01-01

    International audience; The detection of bacterial concentration is important in different fields since high microbial contamination or the presence of particular pathogens can seriously endanger human health. The reference technique to measure bacterial concentration is Standard Plate Count (SPC) that, however, has long response times (24 to 72 hours) and is not suitable for automatic implementation. This paper presents a portable embedded system for bacterial concentration measurement based...

  16. Photoinduced nucleation: A novel tool for detecting molecules in air at ultra-low concentrations

    International Nuclear Information System (INIS)

    Katz, Joseph L.; Lihavainen, Heikki; Rudek, Markus M.; Salter, Brian C.

    2000-01-01

    This paper describes the development of a novel detection method and the demonstration of its capability to detect substances at concentrations as small as a few parts per trillion. It is shown that photoinduced nucleation is not in itself a nucleation process; rather, supersaturated vapor condenses onto long-lasting clusters formed by chemical reaction of photo-excited molecules. The role of the supersaturated vapor is to increase the size of these photoproducts by condensation to a size readily detectable by light scattering. Furthermore, the measured nucleation rate variation with illumination wavelength exactly matches the substance's vapor-phase UV light absorption wavelength dependence, thus providing species identification. The ability to detect and identify molecules of substances at extremely low concentrations from ambient air is useful for detecting and monitoring pollutants, and for detecting explosives such as TNT. (c) 2000 American Institute of Physics

  17. The sensitivity of the electron transport within bulk zinc-blende gallium nitride to variations in the crystal temperature, the doping concentration, and the non-parabolicity coefficient associated with the lowest energy conduction band valley

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqua, Poppy; O' Leary, Stephen K., E-mail: stephen.oleary@ubc.ca [School of Engineering, The University of British Columbia, 3333 University Way, Kelowna, British Columbia V1V 1V7 (Canada)

    2016-09-07

    Within the framework of a semi-classical three-valley Monte Carlo simulation approach, we analyze the steady-state and transient electron transport that occurs within bulk zinc-blende gallium nitride. In particular, we examine how the steady-state and transient electron transport that occurs within this material changes in response to variations in the crystal temperature, the doping concentration, and the non-parabolicity coefficient associated with the lowest energy conduction band valley. These results are then contrasted with those corresponding to a number of other compound semiconductors of interest.

  18. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    OpenAIRE

    Qing-Hui WANG; Fang MU; Li-Feng WEI

    2014-01-01

    This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or conce...

  19. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    International Nuclear Information System (INIS)

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B.

    1990-01-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis

  20. Detection of microbial concentration in ice-cream using the impedance technique.

    Science.gov (United States)

    Grossi, M; Lanzoni, M; Pompei, A; Lazzarini, R; Matteuzzi, D; Riccò, B

    2008-06-15

    The detection of microbial concentration, essential for safe and high quality food products, is traditionally made with the plate count technique, that is reliable, but also slow and not easily realized in the automatic form, as required for direct use in industrial machines. To this purpose, the method based on impedance measurements represents an attractive alternative since it can produce results in about 10h, instead of the 24-48h needed by standard plate counts and can be easily realized in automatic form. In this paper such a method has been experimentally studied in the case of ice-cream products. In particular, all main ice-cream compositions of real interest have been considered and no nutrient media has been used to dilute the samples. A measurement set-up has been realized using benchtop instruments for impedance measurements on samples whose bacteria concentration was independently measured by means of standard plate counts. The obtained results clearly indicate that impedance measurement represents a feasible and reliable technique to detect total microbial concentration in ice-cream, suitable to be implemented as an embedded system for industrial machines.

  1. Excitation of lowest electronic states of thymine by slow electrons

    Science.gov (United States)

    Chernyshova, I. V.; Kontros, E. J.; Markush, P. P.; Shpenik, O. B.

    2013-11-01

    Excitation of lowest electronic states of the thymine molecules in the gas phase is studied by elec- tron energy loss spectroscopy. In addition to dipole-allowed transitions to singlet states, transitions to the lowest triplet states were observed. The low-energy features of the spectrum at 3.66 and 4.61 eV are identified with the excitation of the first triplet states 13 A' (π → π*) and 13 A″ ( n → π*). The higher-lying features at 4.96, 5.75, 6.17, and 7.35 eV are assigned mainly to the excitation of the π → π* transitions to the singlet states of the molecule. The excitation dynamics of the lowest states is studied. It is found that the first triplet state 13 A'(π → π*) is most efficiently excited at a residual energy close to zero, while the singlet 21 A'(π → π*) state is excited with almost identical efficiency at different residual energies.

  2. Detection of Molecular Oxygen at Low Concentrations Using Quartz Enhanced Photoacoustic Spectroscopy

    Directory of Open Access Journals (Sweden)

    Andreas Pohlkötter

    2010-09-01

    Full Text Available Molecular oxygen is detected at low concentrations using photoacoustic spectroscopy despite its unfavorable photoacoustic properties. The system consists of a seed laser diode, a tapered amplifier and a quartz tuning fork based spectrophone, thus employing quartz enhanced photoacoustic spectroscopy (QEPAS. With this system a detection limit of 13 ppm is reached with a compact and long term stable setup. Further improvement of the detection limit is possible by adding suitable gases to the sample gas that promote the radiationless de-excitation of the oxygen molecules.

  3. Blueberry Galaxies: The Lowest Mass Young Starbursts

    Science.gov (United States)

    Yang, Huan; Malhotra, Sangeeta; Rhoads, James E.; Wang, Junxian

    2017-09-01

    Searching for extreme emission line galaxies allows us to find low-mass metal-poor galaxies that are good analogs of high redshift Lyα emitting galaxies. These low-mass extreme emission line galaxies are also potential Lyman-continuum leakers. Finding them at very low redshifts (z≲ 0.05) allows us to be sensitive to even lower stellar masses and metallicities. We report on a sample of extreme emission line galaxies at z≲ 0.05 (blueberry galaxies). We selected them from SDSS broadband images on the basis of their broadband colors and studied their properties with MMT spectroscopy. From the entire SDSS DR12 photometric catalog, we found 51 photometric candidates. We spectroscopically confirm 40 as blueberry galaxies. (An additional seven candidates are contaminants, and four remain without spectra.) These blueberries are dwarf starburst galaxies with very small sizes (<1 kpc) and very high ionization ([O III]/[O II] ˜ 10-60). They also have some of the lowest stellar masses ({log}(M/{M}⊙ )˜ 6.5{--}7.5) and lowest metallicities (7.1< 12+{log}({{O}}/{{H}})< 7.8) of starburst galaxies. Thus, they are small counterparts to green pea galaxies and high redshift Lyα emitting galaxies.

  4. On the possibility of detecting peaks of radon concentration in working areas

    International Nuclear Information System (INIS)

    Madelaine, G.; Zettwoog, P.

    1979-01-01

    Four methods for the continuous measurement of radon concentration, are described. The first two are based on the measurement of the ionization produced by the gas α disintegration. The third one carries out scintillation measurement of radon present in a chamber. The fourth is based on the disintegration chamber principle. Concerning the possibility of detecting radon concentration peaks, the use of ionization detectors, after a feasibility study seems to be suitable

  5. Ecological and Landscape Drivers of Neonicotinoid Insecticide Detections and Concentrations in Canada's Prairie Wetlands.

    Science.gov (United States)

    Main, Anson R; Michel, Nicole L; Headley, John V; Peru, Kerry M; Morrissey, Christy A

    2015-07-21

    Neonicotinoids are commonly used seed treatments on Canada's major prairie crops. Transported via surface and subsurface runoff into wetlands, their ultimate aquatic fate remains largely unknown. Biotic and abiotic wetland characteristics likely affect neonicotinoid presence and environmental persistence, but concentrations vary widely between wetlands that appear ecologically (e.g., plant composition) and physically (e.g., depth) similar for reasons that remain unclear. We conducted intensive surveys of 238 wetlands, and documented 59 wetland (e.g., dominant plant species) and landscape (e.g., surrounding crop) characteristics as part of a novel rapid wetland assessment system. We used boosted regression tree (BRT) analysis to predict both probability of neonicotinoid analytical detection and concentration. BRT models effectively predicted the deviance in neonicotinoid detection (62.4%) and concentration (74.7%) from 21 and 23 variables, respectively. Detection was best explained by shallow marsh plant species identity (34.8%) and surrounding crop (13.9%). Neonicotinoid concentration was best explained by shallow marsh plant species identity (14.9%) and wetland depth (14.2%). Our research revealed that plant composition is a key indicator and/or driver of neonicotinoid presence and concentration in Prairie wetlands. We recommend wetland buffers consisting of diverse native vegetation be retained or restored to minimize neonicotinoid transport and retention in wetlands, thereby limiting their potential effects on wetland-dependent organisms.

  6. Low-level exposure of guinea pigs and marmosets to sarin vapour in air: Lowest-observable-adverse-effect level (LOAEL) for miosis

    NARCIS (Netherlands)

    Helden, H.P.M. van; Trap, H.C.; Kuijpers, W.C.; Oostdijk, J.P.; Benschop, H.P.; Langenberg, J.P.

    2004-01-01

    The purpose of this pilot study was to indicate, for low-level exposure of conscious guinea pigs and marmoset monkeys to sarin vapour in air, the lowest-observable-adverse-effect level (LOAEL) of sarin for miosis. This is the concentration × time (C·t) value (t = 5 h) of exposure at which miosis

  7. Is action potential threshold lowest in the axon?

    NARCIS (Netherlands)

    Kole, Maarten H. P.; Stuart, Greg J.

    2008-01-01

    Action potential threshold is thought to be lowest in the axon, but when measured using conventional techniques, we found that action potential voltage threshold of rat cortical pyramidal neurons was higher in the axon than at other neuronal locations. In contrast, both current threshold and voltage

  8. The lowest surface brightness disc galaxy known

    International Nuclear Information System (INIS)

    Davies, J.I.; Phillipps, S.; Disney, M.J.

    1988-01-01

    The discovery of a galaxy with a prominent bulge and a dominant extremely low surface brightness disc component is reported. The profile of this galaxy is very similar to the recently discovered giant low surface brightness galaxy Malin 1. The disc central surface brightness is found to be ∼ 26.4 Rμ, some 1.5 mag fainter than Malin 1 and thus by far the lowest yet observed. (author)

  9. Single photon counting fluorescence lifetime detection of pericellular oxygen concentrations.

    Science.gov (United States)

    Hosny, Neveen A; Lee, David A; Knight, Martin M

    2012-01-01

    Fluorescence lifetime imaging microscopy offers a non-invasive method for quantifying local oxygen concentrations. However, existing methods are either invasive, require custom-made systems, or show limited spatial resolution. Therefore, these methods are unsuitable for investigation of pericellular oxygen concentrations. This study describes an adaptation of commercially available equipment which has been optimized for quantitative extracellular oxygen detection with high lifetime accuracy and spatial resolution while avoiding systematic photon pile-up. The oxygen sensitive fluorescent dye, tris(2,2'-bipyridyl)ruthenium(II) chloride hexahydrate [Ru(bipy)(3)](2+), was excited using a two-photon excitation laser. Lifetime was measured using a Becker & Hickl time-correlated single photon counting, which will be referred to as a TCSPC card. [Ru(bipy)(3)](2+) characterization studies quantified the influences of temperature, pH, cellular culture media and oxygen on the fluorescence lifetime measurements. This provided a precisely calibrated and accurate system for quantification of pericellular oxygen concentration based on measured lifetimes. Using this technique, quantification of oxygen concentrations around isolated viable chondrocytes, seeded in three-dimensional agarose gel, revealed a subpopulation of cells that exhibited significant spatial oxygen gradients such that oxygen concentration reduced with increasing proximity to the cell. This technique provides a powerful tool for quantifying spatial oxygen gradients within three-dimensional cellular models.

  10. Assessment of eight HPV vaccination programs implemented in lowest income countries

    OpenAIRE

    Ladner, Joël; Besson, Marie-Hélène; Hampshire, Rachel; Tapert, Lisa; Chirenje, Mike; Saba, Joseph

    2012-01-01

    Abstract Background Cervix cancer, preventable, continues to be the third most common cancer in women worldwide, especially in lowest income countries. Prophylactic HPV vaccination should help to reduce the morbidity and mortality associated with cervical cancer. The purpose of the study was to describe the results of and key concerns in eight HPV vaccination programs conducted in seven lowest income countries through the Gardasil Access Program (GAP). Methods The GAP provides free HPV vaccin...

  11. An ELM Based Online Soft Sensing Approach for Alumina Concentration Detection

    Directory of Open Access Journals (Sweden)

    Sen Zhang

    2015-01-01

    Full Text Available The concentration of alumina in the electrolyte is of great significance during the production of aluminum; it may affect the stability of aluminum reduction cell and the current efficiency. However, the concentration of alumina is hard to be detected online because of the special circumstance in the aluminum reduction cell. At present, there is lack of fast and accurate soft sensing methods for alumina concentration and existing methods can not meet the needs for online measurement. In this paper, a novel soft sensing method based on a modified extreme learning machine (MELM for online measurement of the alumina concentration is proposed. The modified ELM algorithm is based on the enhanced random search which is called incremental extreme learning machine in some references. It randomly chooses the input weights and analytically determines the output weights without manual intervention. The simulation results show that the approach can give more accurate estimations of alumina concentration with faster learning speed compared with other methods such as BP and SVM.

  12. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy.

    Science.gov (United States)

    Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie

    2017-11-21

    This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  13. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Rufeng Li

    2017-11-01

    Full Text Available This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1 Gaussian filtering to remove the noise of overall fluorescent targets, (2 a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3 an red maximizing inter-class variance thresholding method (OTSU to segment the enhanced image for getting the binary map of the overall micro-droplets, (4 a circular Hough transform (CHT method to detect overall micro-droplets and (5 an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  14. Preparations for an optical access to the lowest nuclear excitation in {sup 229}Th

    Energy Technology Data Exchange (ETDEWEB)

    Wense, Lars v.d.; Seiferle, Benedict; Thirolf, Peter G. [Ludwig-Maximilians-Universitaet Muenchen (Germany); Laatiaoui, Mustapha [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany)

    2015-07-01

    The isomeric lowest excited nuclear level of {sup 229}Th has been indirectly measured to be 7.6±0.5 eV (163±11 nm). This low transition energy, compared to energies typically involved in nuclear processes, would allow for the application of laser-spectroscopic methods. Also considering the isomeric lifetime of the excited state (estimated to be 10{sup 3} to 10{sup 4} s), which leads to an extremely sharp linewidth of Δω/ω ∝ 10{sup -20}, the isomer becomes a strong candidate for a nuclear-based frequency standard. In order to directly detect the isomeric ground-state decay and improve the accuracy of its energy as a prerequisite for an all-optical control, {sup 229m}Th is populated via a 2% decay branch in the α decay of {sup 233}U. The Thorium ions are extracted and cooled with the help of a buffer-gas stopping cell and an RFQ-cooler. In order to suppress accompanying α decay chain products other than {sup 229}Th, a quadrupole mass spectrometer (QMS) is used. Following the QMS, the Thorium isomeric decay is expected to be detectable. Internal conversion as well as photonic decay is probed via different detection techniques. Latest results are presented.

  15. Pricing strategies for combination pediatric vaccines based on the lowest overall cost formulary.

    Science.gov (United States)

    Behzad, Banafsheh; Jacobson, Sheldon H; Sewell, Edward C

    2012-10-01

    This paper analyzes pricing strategies for US pediatric combination vaccines by comparing the lowest overall cost formularies (i.e., formularies that have the lowest overall cost). Three pharmaceutical companies compete pairwise over the sale of monovalent and combination vaccines. Particular emphasis is placed on examining the price of Sanofi Pasteur's DTaP-IPV/HIb under different conditions. The main contribution of the paper is to provide the lowest overall cost formularies for different prices of DTaP-IPV/HIb and other Sanofi Pasteur vaccines. The resulting analysis shows that DTaP-IPV/HIb could have been more competitively priced compared with the combination vaccine DTaP-HepB-IPV, for federal contract prices in 2009, 2010 and 2011. This study also proposes the lowest overall cost formularies when shortages of monovalent vaccines occur.

  16. The lowest Landau level in QCD

    Directory of Open Access Journals (Sweden)

    Bruckmann Falk

    2017-01-01

    Full Text Available The thermodynamics of Quantum Chromodynamics (QCD in external (electro-magnetic fields shows some unexpected features like inverse magnetic catalysis, which have been revealed mainly through lattice studies. Many effective descriptions, on the other hand, use Landau levels or approximate the system by just the lowest Landau level (LLL. Analyzing lattice configurations we ask whether such a picture is justified. We find the LLL to be separated from the rest by a spectral gap in the two-dimensional Dirac operator and analyze the corresponding LLL signature in four dimensions. We determine to what extent the quark condensate is LLL dominated at strong magnetic fields.

  17. Detection of ethylene gas in exhaled breath of people living in landfill using CO{sub 2} laser photoacoustic spectroscopy with multicomponent analysis

    Energy Technology Data Exchange (ETDEWEB)

    Oktafiani, Fitri, E-mail: fitri.oktafiani@mail.ugm.ac.id; Stiyabudi, Rizky; Amin, Mochamad Nurul; Mitrayana [Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara BLS 21, Yogyakarta, 55281 Indonesia (Indonesia)

    2016-06-17

    The photoacoustic spectrometer (PAS) had been built and the performance had been determined. The research was based on the conversion of the absorbed middle infra red (IR) radiation by gas confined in a closed PAS cell into standing acoustic wave, which could be detected by a suitable electroacoustic transducer such as a microphone. The lowest detection limit for this setup was (57,1 ± 0,3) ppb and quality factor was (14,5 ± 0,6) for ethylene gas in 10P14 CO{sub 2} laser line. Then, this PAS was used to measure of ethylene gas concentration in breath sample of people living in near the Piyungan Bantul Yogyakarta landfill. The result from multicomponent analysis showed that PAS enable to measure the lowest concentration of volatile organic compound (VOC), such as ethylene, which occured on ambien air in Piyungan landfill. Variaty of distance area applied in this research. In the range of ±0,5 km from landfill, we obtained the concentration of ethylene gas concentration for human breath was (1,520 ± 0,002) ppm, while in the range of ±45 km, the ethylene gas concentration for human breath was (0,424 ± 0,002) ppm. Ethylene gas concentrations in exhaled gas decreased along with increasing distance variation of the landfill.

  18. A laser-based FAIMS detector for detection of ultra-low concentrations of explosives

    Science.gov (United States)

    Akmalov, Artem E.; Chistyakov, Alexander A.; Kotkovskii, Gennadii E.; Sychev, Alexey V.; Tugaenko, Anton V.; Bogdanov, Artem S.; Perederiy, Anatoly N.; Spitsyn, Eugene M.

    2014-06-01

    A non-contact method for analyzing of explosives traces from surfaces was developed. The method is based on the laser desorption of analyzed molecules from the surveyed surfaces followed by the laser ionization of air sample combined with the field asymmetric ion mobility spectrometry (FAIMS). The pulsed radiation of the fourth harmonic of a portable GSGG: Cr3+ :Nd3+ laser (λ = 266 nm) is used. The laser desorption FAIMS analyzer have been developed. The detection limit of the analyzer equals 40 pg for TNT. The results of detection of trinitrotoluene (TNT), cyclotrimethylenetrinitramine (RDX) and cyclotetramethylenetetranitramine (HMX) are presented. It is shown that laser desorption of nitro-compounds from metals is accompanied by their surface decomposition. A method for detecting and analyzing of small concentrations of explosives in air based on the laser ionization and the FAIMS was developed. The method includes a highly efficient multipass optical scheme of the intracavity fourthharmonic generation of pulsed laser radiation (λ = 266 nm) and the field asymmetric ion mobility (FAIM) spectrometer disposed within a resonator. The ions formation and detection proceed inside a resonant cavity. The laser ion source based on the multi-passage of radiation at λ = 266 nm through the ionization region was elaborated. On the basis of the method the laser FAIMS analyzer has been created. The analyzer provides efficient detection of low concentrations of nitro-compounds in air and shows a detection limit of 10-14 - 10-15 g/cm3 both for RDX and TNT.

  19. TRACING THE LOWEST PROPELLER LINE IN MAGELLANIC HIGH-MASS X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, Dimitris M.; Laycock, Silas G. T.; Yang, Jun; Fingerman, Samuel, E-mail: dimitris_christodoulou@uml.edu, E-mail: silas_laycock@uml.edu, E-mail: jun_yang@uml.edu, E-mail: fingerman.samuel@gmail.com [Lowell Center for Space Science and Technology, 600 Suffolk Street, Lowell, MA 01854 (United States)

    2016-09-20

    We have combined the published observations of high-mass X-ray binary (HMXB) pulsars in the Magellanic Clouds with a new processing of the complete archival data sets from the XMM-Newton and Chandra observatories in an attempt to trace the lowest propeller line below which accretion to polar caps is inhibited by the centrifugal force and the pulsations from the most weakly magnetized pulsars cease. Previously published data reveal that some of the faster-spinning pulsars with spin periods of P {sub S} < 12 s, detected at relatively low X-ray luminosities L {sub X} , appear to define such a line in the P {sub S} – L {sub X} diagram, characterized by a magnetic moment of μ = 3 × 10{sup 29} G cm{sup 3}. This value implies the presence of surface magnetic fields of B ≥ 3 × 10{sup 11} G in the compact objects of this class. Only a few quiescent HMXBs are found below the propeller line: LXP4.40 and SXP4.78, for which XMM-Newton and Chandra null detections respectively placed firm upper limits on their X-ray fluxes in deep quiescence; and A0538-66, for which many sub-Eddington detections have never measured any pulsations. On the other hand, the data from the XMM-Newton and Chandra archives show clearly that, during routine observation cycles, several sources have been detected below the propeller line in extremely faint, nonpulsating states that can be understood as the result of weak magnetospheric emission when accretion to the poles is centrifugally stalled or severely diminished. We also pay attention to the anomalous X-ray pulsar CXOU J010043.1-721134 that was reported in HMXB surveys. Its pulsations and locations near and above the propeller line indicate that this pulsar could be accreting from a fossil disk.

  20. Concentration of bisphenol A in highly consumed canned foods on the U.S. market.

    Science.gov (United States)

    Noonan, Gregory O; Ackerman, Luke K; Begley, Timothy H

    2011-07-13

    Metal food and drink cans are commonly coated with epoxy films made from phenolic polymers produced from bisphenol A (BPA). It is well established that residual BPA monomer migrates into can contents during processing and storage. While a number of studies have reported BPA concentrations in foods from foreign markets and specialty foods on the U.S. market, very few peer-reviewed data for the BPA concentrations in canned food from the U.S. market were available. This study quantified BPA concentrations in 78 canned and two frozen food products from the U.S. market using an adaptation of a previously reported liquid chromatography-tandem mass spectrometry method. The tested products represented 16 different food types that are from the can food classifications that constitute approximately 65% of U.S. canned food sales and canned food consumption. BPA was detected in 71 of the 78 canned food samples but was not detected in either of the two frozen food samples. Detectable BPA concentrations across all foods ranged from 2.6 to 730 ng/g. Large variations in BPA concentrations were found between different products of the same food type and between different lots of the same product. Given the large concentration ranges, the only distinguishable trend was that fruits and tuna showed the lowest BPA concentrations. Experiments with fortified frozen vegetables and brine solutions, as well as higher BPA concentrations in canned food solids over liquid portions, clearly indicated that BPA partitions into the solid portion of foods.

  1. Detection of atmospheric tritium by scintillation. Variations in its concentration in France

    International Nuclear Information System (INIS)

    Bibron, R.

    1964-06-01

    The tritium released into the atmosphere as a result of the explosion of thermonuclear devices is a useful radioactive tracer for the study of certain geophysical problems. The low concentrations found however call for the use of extremely sensitive detectors. Two detection methods using liquid scintillators are described. In the first method, the sample is introduced into the scintillator in liquid form, after prior concentration of the tritium by electrolysis. In the second method the tritium is incorporated into the scintillator solvent molecule by chemical synthesis. In the last part of the report are examined the variations in the tritium concentration in rain-water and of the free hydrogen in the air in France. A discussion is then made of the seasonal variations in the case of rain-water and these are compared to the variations in the strontium-90 concentrations. (author) [fr

  2. Improved OAM-Based Radar Targets Detection Using Uniform Concentric Circular Arrays

    Directory of Open Access Journals (Sweden)

    Mingtuan Lin

    2016-01-01

    Full Text Available Without any relative moves or beam scanning, the novel Orbital-Angular-Momentum- (OAM- based radar targets detection technique using uniform concentric circular arrays (UCCAs shows the azimuthal estimation ability, which provides new perspective for radar system design. However, the main estimation method, that is, Fast Fourier Transform (FFT, under this scheme suffers from low resolution. As a solution, this paper rebuilds the OAM-based radar targets detection model and introduces the multiple signal classification (MUSIC algorithm to improve the resolution for detecting targets within the main lobes. The spatial smoothing technique is proposed to tackle the coherent problem brought by the proposed model. Analytical study and simulation demonstrate the superresolution estimation capacity the MUSIC algorithm can achieve for detecting targets within the main lobes. The performance of the MUSIC algorithm to detect targets not illuminated by the main lobes is further evaluated. Despite the fact that MUSIC algorithm loses the resolution advantage under this case, its estimation is more robust than that of the FFT method. Overall, the proposed MUSIC algorithm for the OAM-based radar system demonstrates the superresolution ability for detecting targets within the main lobes and good robustness for targets out of the main lobes.

  3. Multi-scale magnetic nanoparticle based optomagnetic bioassay for sensitive DNA and bacteria detection

    DEFF Research Database (Denmark)

    Tian, Bo; Zardán Gómez De La Torre, Teresa; Donolato, Marco

    2016-01-01

    nanoparticles (binding to the target) and thus the optomagnetic response of the sample, which is measured by an optomagnetic setup including a 405 nm laser and a photodetector. The limit of detection is mainly set by the lowest measurable concentration of magnetic nanoparticles. Herein, as new results compared...... with the target. We show that the optimization and lowering of the 100 nm magnetic nanoparticle concentration result in a limit of detection of 780 fM of DNA coils formed by rolling circle amplification (size of about 1 μm) and 105 CFU per mL Salmonella (for immunoassay). These values are 15 times lower than...... those reported previously for this readout principle. Finally, we show that the 250 nm magnetic nanoparticles can serve as a second detection label for qualitative biplex detection of DNA coils formed by rolling circle amplification from V. cholerae and E. coli DNA coils using 100 nm and 250 nm magnetic...

  4. 48 CFR 47.306-2 - Lowest overall transportation costs.

    Science.gov (United States)

    2010-10-01

    ... transportation costs. 47.306-2 Section 47.306-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT TRANSPORTATION Transportation in Supply Contracts 47.306-2 Lowest overall transportation costs. (a) For the evaluation of offers, the transportation officer shall give to the contracting...

  5. Sugar type and concentration preference of the Cape white-eye ...

    African Journals Online (AJOL)

    . ... Minke Witteveen, Mark Brown ... sugar type preference at any sugar concentration, but showed a preference for the lowest concentration (10%) of both hexose and sucrose solutions when presented with a range of sugar concentrations.

  6. Development of a homogeneous pulse shape discriminating flow-cell radiation detection system

    International Nuclear Information System (INIS)

    Hastie, K.H.; DeVol, T.A.; Fjeld, R.A.

    1999-01-01

    A homogeneous flow-cell radiation detection system which utilizes coincidence counting and pulse shape discrimination circuitry was assembled and tested with five commercially available liquid scintillation cocktails. Two of the cocktails, Ultima Flo (Packard) and Mono Flow 5 (National Diagnostics) have low viscosities and are intended for flow applications; and three of the cocktails, Optiphase HiSafe 3 (Wallac), Ultima Gold AB (Packard), and Ready Safe (Beckman), have higher viscosities and are intended for static applications. The low viscosity cocktails were modified with 1-methylnaphthalene to increase their capability for alpha/beta pulse shape discrimination. The sample loading and pulse shape discriminator setting were optimized to give the lowest minimum detectable concentration for methylnaphthalenein a 30 s count time. Of the higher viscosity cocktails, Optiphase HiSafe 3 had the lowest minimum detectable activities for alpha and beta radiation, 0.2 and 0.4 Bq/ml for 233 U and 90 Sr/ 90 Y, respectively, for a 30 s count time. The sample loading was 70% and the corresponding alpha/beta spillover was 5.5%. Of the low viscosity cocktails, Mono Flow 5 modified with 2.5% (by volume) 1-methylnaphthalene resulted in the lowest minimum detectable activities for alpha and beta radiation; 0.3 and 0.5 Bq/ml for 233 U and 90 Sr/ 90 Y, respectively, for a 30 s count time. The sample loading was 50%, and the corresponding alpha/beta spillover was 16.6%. HiSafe 3 at a 10% sample loading was used to evaluate the system under simulated flow conditions

  7. Radioanalytical methods for the measurement of melanin concentrating hormone (MCH) and detection its receptor in rat tissues

    International Nuclear Information System (INIS)

    Lelesz, B.; Szilvassy, Z.; Varga, A.; Juhasz, B.; Nemeth, J.; Toth, G.K.; Toth, A.; Enyedi, A.; Felszeghy, E.

    2016-01-01

    In the present paper the development and application of a novel melanin concentrating hormone radioimmunoassay and receptor-binding assay are described. 125 I-labeling of melanin concentrating hormone (MCH) was performed by iodogen and the mono-iodinated peptide was separated by reversed-phase high performance liquid chromatography. Detection limit of the MCH specific assay was 0.2 fmol/ml. As a practical application of the novel radioimmunoassay, we measured the MCH concentration in different rat organs. High MCH concentrations were detected in the small intestine, pancreas, kidney, liver, trachea, hypothalamus and spinal cord. 125 I-MCH was also suitable for RBA to demonstrate the presence of MCH receptors in the rat brain. (author)

  8. Lowest-order average effect of turbulence on atmospheric profiles derived from radio occultation

    International Nuclear Information System (INIS)

    Eshleman, V.R.; Haugstad, B.S.

    1977-01-01

    Turbulence in planetary atmospheres and ionospheres causes changes in angles of refraction of radio waves used in occultation experiments. Atmospheric temperature and pressure profiles, and ionospheric electron concentration profiles, derived from radio occultation measurements of Doppler frequency contain errors due to such angular offsets. The lowest-order average errors are derived from a geometrical-optics treatment of the radio-wave phase advance caused by the addition of uniform turbulence to an initially homogeneous medium. It is concluded that the average profile errors are small and that precise Doppler frequency measurements at two or more wavelengths could be used to help determine characteristics of the turbulence, as well as accuracy limits and possible correction terms for the profiles. However, a more detailed study of both frequency and intensity characteristics in radio and optical occultation measurements of turbulent planetary atmospheres and ionospheres is required to realize the full potential of such measurements

  9. Electron mobility on the surface of liquid Helium: influence of surface level atoms and depopulation of lowest subbands

    International Nuclear Information System (INIS)

    Grigoriev, P. D.; Dyugaev, A. M.; Lebedeva, E. V.

    2008-01-01

    The temperature dependence of electron mobility is examined. We calculate the contribution to the electron scattering rate from the surface level atoms (SLAs), proposed in [10]. This contribution is substantial at low temperatures T < 0.5, when the He vapor concentration is exponentially small. We also study the effect of depopulation of the lowest energy subband, which leads to an increase in the electron mobility at high temperature. The results explain certain long-standing discrepancies between the existing theory and experiment on electron mobility on the surface of liquid helium

  10. Ecophysiological and seasonal variations in Cd, Pb, Zn, and Ni concentrations in the leaves of urban deciduous trees in Istanbul

    International Nuclear Information System (INIS)

    Baycu, Guelriz; Tolunay, Doganay; Ozden, Hakan; Guenebakan, Suereyya

    2006-01-01

    The concentrations of Cd, Pb, Zn and Ni were measured in the leaves of 7 species of deciduous trees, from the urban sites of Istanbul, in both the Spring and Autumn seasons. We detected some differences in the heavy metal concentrations of the control and urban site samples of identical species. Highest concentrations of Cd were detected in Populus, Pb in Aesculus and Robinia, Zn in Populus, and Ni in Robinia and Fraxinus. Lowest chlorophyll content and highest peroxidase (POD) activity was found in the urban site samples of Acer. We have found a positive correlation between the increase in the POD activity and the Pb concentration in Populus. Generally, the tree species investigated in this study, are considered to have different tolerance levels to heavy metal pollution. The data obtained show that the chlorophyll content and the POD activity may be used as heavy metal stress biomarkers in the urban trees. - Ecophysiological changes in the urban trees may be used as heavy metal stress biomarkers

  11. CADMIUM, COPPER, LEAD AND ZINC CONCENTRATIONS IN LOW QUALITY WINES AND ALCOHOL CONTAINING DRINKS FROM ITALY, BULGARIA AND POLAND

    Directory of Open Access Journals (Sweden)

    Renata Muchacka

    2012-02-01

    Full Text Available We studied Cu, Cd, Pb and Zn concentrations in low quality wines produced in Bulgaria and Italy and in alcohol containing multi-fruit drinks produced in Poland. All the metals were present in tested products. Cadmium was not detected in Italian and Polish products. In one of the Bulgarian wines cadmium was detected in concentration of 0.004 mg•l-1. Italian wines were not contaminated with Pb. Its concentration was the highest in Polish drinks (0.88±0.52 mg•l-1. The largest and statistically significant differences occurred between Cu and Zn contents. Both metals had the highest concetrations in Italian wines (Cu - 0.13±0.05 mg•l-1; Zn - 0.83±0.56 mg•l-1, and the lowest in Polish products (Cu - 0.04±0.001 mg•l-1; Zn -0.18±0.16 mg•l-1.

  12. Detection of protozoa in water samples by formalin/ether concentration method.

    Science.gov (United States)

    Lora-Suarez, Fabiana; Rivera, Raul; Triviño-Valencia, Jessica; Gomez-Marin, Jorge E

    2016-09-01

    Methods to detect protozoa in water samples are expensive and laborious. We evaluated the formalin/ether concentration method to detect Giardia sp., Cryptosporidium sp. and Toxoplasma in water. In order to test the properties of the method, we spiked water samples with different amounts of each protozoa (0, 10 and 50 cysts or oocysts) in a volume of 10 L of water. Immunofluorescence assay was used for detection of Giardia and Cryptosporidium. Toxoplasma oocysts were identified by morphology. The mean percent of recovery in 10 repetitions of the entire method, in 10 samples spiked with ten parasites and read by three different observers, were for Cryptosporidium 71.3 ± 12, for Giardia 63 ± 10 and for Toxoplasma 91.6 ± 9 and the relative standard deviation of the method was of 17.5, 17.2 and 9.8, respectively. Intraobserver variation as measured by intraclass correlation coefficient, was fair for Toxoplasma, moderate for Cryptosporidium and almost perfect for Giardia. The method was then applied in 77 samples of raw and drinkable water in three different plant of water treatment. Cryptosporidium was found in 28 of 77 samples (36%) and Giardia in 31 of 77 samples (40%). Theses results identified significant differences in treatment process to reduce the presence of Giardia and Cryptosporidium. In conclusion, the formalin ether method to concentrate protozoa in water is a new alternative for low resources countries, where is urgently need to monitor and follow the presence of theses protozoa in drinkable water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. A Florescence Detection Module for Photodynamic Therapy Optimization by Measuring the Concentration of Photo sensitizer

    International Nuclear Information System (INIS)

    Serrano Navarro, Joel; Stolik Isakina, Suren; La Rosa Vazquez, Jose M. de; Valor Reed, Alma

    2016-01-01

    In the present work, a portable fluorescence detection system designed and built for dosimetry control applications in Photodynamic Therapy is presented. The system excites the used photo sensitizer drug with a modulated laser light source and subsequently measures the radiance of the emitted fluorescent light. Since the fluorescent radiance is directly related to the photosensitizers concentration, this measurement allows for real-time monitoring of the photo sensitizer concentration in the treated tissue. The system is thought to permit adjusting the therapeutic regime in order to optimize the expected therapy results. In the developed system, a synchronous detection technique is employed to recover the fluorescence signals embedded in noisy backgrounds and lit environments. A scanning probe with a 405 nm diode laser is used to excite the photo sensitizer, while a detection wavelength range from 590 nm to 700 nm has been implemented. (Author)

  14. Bacterial contamination of platelet concentrates: pathogen detection and inactivation methods

    Directory of Open Access Journals (Sweden)

    Dana Védy

    2009-04-01

    Full Text Available Whereas the reduction of transfusion related viral transmission has been a priority during the last decade, bacterial infection transmitted by transfusion still remains associated to a high morbidity and mortality, and constitutes the most frequent infectious risk of transfusion. This problem especially concerns platelet concentrates because of their favorable bacterial growth conditions. This review gives an overview of platelet transfusion-related bacterial contamination as well as on the different strategies to reduce this problem by using either bacterial detection or inactivation methods.

  15. Lowest-order constrained variational method for simple many-fermion systems

    International Nuclear Information System (INIS)

    Alexandrov, I.; Moszkowski, S.A.; Wong, C.W.

    1975-01-01

    The authors study the potential energy of many-fermion systems calculated by the lowest-order constrained variational (LOCV) method of Pandharipande. Two simple two-body interactions are used. For a simple hard-core potential in a dilute Fermi gas, they find that the Huang-Yang exclusion correction can be used to determine a healing distance. The result is close to the older Pandharipande prescription for the healing distance. For a hard core plus attractive exponential potential, the LOCV result agrees closely with the lowest-order separation method of Moszkowski and Scott. They find that the LOCV result has a shallow minimum as a function of the healing distance at the Moszkowski-Scott separation distance. The significance of the absence of a Brueckner dispersion correction in the LOCV result is discussed. (Auth.)

  16. Bumblebees are not deterred by ecologically relevant concentrations of nectar toxins.

    Science.gov (United States)

    Tiedeken, Erin Jo; Stout, Jane C; Stevenson, Philip C; Wright, Geraldine A

    2014-05-01

    Bees visit flowers to collect nectar and pollen that contain nutrients and simultaneously facilitate plant sexual reproduction. Paradoxically, nectar produced to attract pollinators often contains deterrent or toxic plant compounds associated with herbivore defence. The functional significance of these nectar toxins is not fully understood, but they may have a negative impact on pollinator behaviour and health, and, ultimately, plant pollination. This study investigates whether a generalist bumblebee, Bombus terrestris, can detect naturally occurring concentrations of nectar toxins. Using paired-choice experiments, we identified deterrence thresholds for five compounds found in the nectar of bee-pollinated plants: quinine, caffeine, nicotine, amygdalin and grayanotoxin. The deterrence threshold was determined when bumblebees significantly preferred a sucrose solution over a sucrose solution containing the compound. Bumblebees had the lowest deterrence threshold for the alkaloid quinine (0.01 mmol l(-1)); all other compounds had higher deterrence thresholds, above the natural concentration range in floral nectar. Our data, combined with previous work using honeybees, suggest that generalist bee species have poor acuity for the detection of nectar toxins. The fact that bees do not avoid nectar-relevant concentrations of these compounds likely indicates that it is difficult for them to learn to associate floral traits with the presence of toxins, thus maintaining this trait in plant populations.

  17. Radionuclide concentrations in fish and invertebrates from Bikini Atoll

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Jokela, T.A.; Brunk, J.A.

    1988-01-01

    As in other global studies, 137 Cs was found in the highest concentrations in edible flesh of all species of fish and in the lowest concentrations in the bone or liver. The mean concentration of 137 Cs in muscle of reef fish from the southern part of the atoll is comparable to the global-fallout concentration measured in market samples of fish collected from Chicago, IL, USA, in 1982. Strontium-90 is associated generally with non-edible parts of fish, such as bone or viscera. Twenty-five to fifty percent of the total body burden of 60 Co is accumulated in the muscle tissue; the remainder is distributed among the liver, skin, and viscera. The mean concentration of 60 Co in fish has been decreasing at a rate faster than radiological decay alone. Most striking is the range of 207 Bi concentrations among different species of fish collected at the same time and place. Highest concentrations of 207 Bi were consistently detected in the muscle and other tissues of goatfish and some of the pelagic lagoon fish. In other reef fish, such as mullet, surgeonfish, and parrotfish, 207 Bi was usually below detection limits by gamma spectrometry. Over 70% of the whole-body activity of 207 Bi in goatfish is associated with the muscle tissue, whereas less than 5% is found in the muscle of mullet and surgeonfish. Neither 239+240 Pu nor 241 Am is accumulated significantly in the muscle tissue of any species of fish. Apparently, 238 Pu is in a more readily available form for accumulation by fishes than 239+240 Pu. Based on a daily ingestion rate of 200 g of fish flesh, dose rates to individuals through the fish-food ingestion pathway are well below current Federal guidelines. 24 refs., 1 fig., 27 tabs

  18. Immobilization with Metal Hydroxides as a Means To Concentrate Food-Borne Bacteria for Detection by Cultural and Molecular Methods†

    OpenAIRE

    Lucore, Lisa A.; Cullison, Mark A.; Jaykus, Lee-Ann

    2000-01-01

    The application of nucleic acid amplification methods to the detection of food-borne pathogens could be facilitated by concentrating the organisms from the food matrix before detection. This study evaluated the utility of metal hydroxide immobilization for the concentration of bacterial cells from dairy foods prior to detection by cultural and molecular methods. Using reconstituted nonfat dry milk (NFDM) as a model, two food-borne pathogens (Listeria monocytogenes and Salmonella enterica sero...

  19. Contract Source Selection: An Analysis of Lowest Price Technically Acceptable and Tradeoff Strategies

    Science.gov (United States)

    2016-06-15

    using- spss - statistics.php Lamoureux, J., Murrow, M., & Walls, C. (2015). Relationship of source selection methods to contract outcomes: an analysis ...Contract Source Selection: an Analysis of Lowest Price Technically Acceptable and Tradeoff Strategies 15 June 2016 LCDR Jamal M. Osman, USN...ACQUISITION RESEARCH PROGRAM SPONSORED REPORT SERIES Contract Source Selection: an Analysis of Lowest Price Technically Acceptable and Tradeoff

  20. Strontium and zinc concentrations in otoliths of common fish species in the northern Baltic Sea

    Energy Technology Data Exchange (ETDEWEB)

    Lill, J.-O., E-mail: jlill@abo.fi [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University, Porthansgatan 3, FI-20500 Turku (Finland); Himberg, M. [Laboratory of Aquatic Pathobiology, Husö Biological Station, Environmental and Marine Biology, Department of Biosciences, Åbo Akademi University, Artillerigatan 6, FI-20520 Turku (Finland); Harju, L.; Ek, P. [Analytical Chemistry, Department of Chemical Engineering, Åbo Akademi University, Biskopsgatan 8, FI-20500 Turku (Finland); Lindroos, A. [Geology and Mineralogy, Department of Natural Sciences, Åbo Akademi University, Domkyrkotorget, FI-20500 Turku (Finland); Wiklund, T. [Laboratory of Aquatic Pathobiology, Husö Biological Station, Environmental and Marine Biology, Department of Biosciences, Åbo Akademi University, Artillerigatan 6, FI-20520 Turku (Finland); Gunnelius, K.; Smått, J.-H. [Physical Chemistry, Department of Natural Sciences, Åbo Akademi University, Porthansgatan 3, FI-20500 Turku (Finland); Heselius, S.-J. [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University, Porthansgatan 3, FI-20500 Turku (Finland); Hägerstrand, H. [Laboratory of Aquatic Pathobiology, Husö Biological Station, Environmental and Marine Biology, Department of Biosciences, Åbo Akademi University, Artillerigatan 6, FI-20520 Turku (Finland)

    2014-01-01

    Otoliths of perch (Perca fluviatilis), pike (Esox lucius) and European whitefish (Coregonus lavaretus) caught at different locations in the northern Baltic Sea along the Finnish west coast and at some rivers and lakes were subjected to elemental analyses with particle induced X-ray emission and laser ablation inductively coupled plasma mass spectrometry. The strontium concentration in otoliths from whitefish (∼3300 μg/g) was 2–3 times higher than that of perch and pike (∼1400 μg/g), while within species the strontium concentration of otoliths from fish caught at different locations was in the same range. The strontium concentrations were lowest in fish from the lakes (∼450 μg/g). Whitefish otoliths contained more zinc (∼60 μg/g) than those of pike (∼30 μg/g), while the zinc concentration in perch otoliths were below the detection limit. No spatial intraspecies variations in zinc concentrations were observed. X-ray diffraction showed that the otoliths consisted of aragonite solely.

  1. Strontium and zinc concentrations in otoliths of common fish species in the northern Baltic Sea

    International Nuclear Information System (INIS)

    Lill, J.-O.; Himberg, M.; Harju, L.; Ek, P.; Lindroos, A.; Wiklund, T.; Gunnelius, K.; Smått, J.-H.; Heselius, S.-J.; Hägerstrand, H.

    2014-01-01

    Otoliths of perch (Perca fluviatilis), pike (Esox lucius) and European whitefish (Coregonus lavaretus) caught at different locations in the northern Baltic Sea along the Finnish west coast and at some rivers and lakes were subjected to elemental analyses with particle induced X-ray emission and laser ablation inductively coupled plasma mass spectrometry. The strontium concentration in otoliths from whitefish (∼3300 μg/g) was 2–3 times higher than that of perch and pike (∼1400 μg/g), while within species the strontium concentration of otoliths from fish caught at different locations was in the same range. The strontium concentrations were lowest in fish from the lakes (∼450 μg/g). Whitefish otoliths contained more zinc (∼60 μg/g) than those of pike (∼30 μg/g), while the zinc concentration in perch otoliths were below the detection limit. No spatial intraspecies variations in zinc concentrations were observed. X-ray diffraction showed that the otoliths consisted of aragonite solely

  2. Method and apparatus for detecting dilute concentrations of radioactive xenon in samples of xenon extracted from the atmosphere

    Science.gov (United States)

    Warburton, William K.; Hennig, Wolfgang G.

    2018-01-02

    A method and apparatus for measuring the concentrations of radioxenon isotopes in a gaseous sample wherein the sample cell is surrounded by N sub-detectors that are sensitive to both electrons and to photons from radioxenon decays. Signal processing electronics are provided that can detect events within the sub-detectors, measure their energies, determine whether they arise from electrons or photons, and detect coincidences between events within the same or different sub-detectors. The energies of detected two or three event coincidences are recorded as points in associated two or three-dimensional histograms. Counts within regions of interest in the histograms are then used to compute estimates of the radioxenon isotope concentrations. The method achieves lower backgrounds and lower minimum detectable concentrations by using smaller detector crystals, eliminating interference between double and triple coincidence decay branches, and segregating double coincidences within the same sub-detector from those occurring between different sub-detectors.

  3. All Electron ab initio Investigations of the Three Lowest Lying Electronic States of the RuC Molecule

    DEFF Research Database (Denmark)

    Shim, Irene; Gingerich, K. A.

    2000-01-01

    The three lowest-lying electronic states of RuC, (1)Sigma(+), (3)Delta, and (1)Delta, have been investigated by performing all-electron ab initio multi-configuration self-consistent-field (CASSCF) and multi-reference configuration interaction (MRCI) calculations including relativistic corrections....... The electronic ground state is derived as (1)Sigma(+) with the spectroscopic constants r(e) = 1.616 Angstrom and omega(e) = 1085 cm(-1). The lowest-lying excited state, (3)Delta, has r(e) = 1.632 Angstrom, omega(e) = 1063 cm(-1), and T-e = 912 cm(-1). These results are consistent with recent spectroscopic values....... The chemical bonds in all three lowest-lying states are triple bonds composed of one sigma and two pi bonds. (C) 2000 Elsevier Science B.V. All rights reserved....

  4. Echographic detectability of optoacoustic signals from low-concentration PEG-coated gold nanorods.

    Science.gov (United States)

    Conversano, Francesco; Soloperto, Giulia; Greco, Antonio; Ragusa, Andrea; Casciaro, Ernesto; Chiriacò, Fernanda; Demitri, Christian; Gigli, Giuseppe; Maffezzoli, Alfonso; Casciaro, Sergio

    2012-01-01

    To evaluate the diagnostic performance of gold nanorod (GNR)-enhanced optoacoustic imaging employing a conventional echographic device and to determine the most effective operative configuration in order to assure optoacoustic effectiveness, nanoparticle stability, and imaging procedure safety. The most suitable laser parameters were experimentally determined in order to assure nanoparticle stability during the optoacoustic imaging procedures. The selected configuration was then applied to a novel tissue-mimicking phantom, in which GNR solutions covering a wide range of low concentrations (25-200 pM) and different sample volumes (50-200 μL) were exposed to pulsed laser irradiation. GNR-emitted optoacoustic signals were acquired either by a couple of single-element ultrasound probes or by an echographic transducer. Off-line analysis included: (a) quantitative evaluation of the relationships between GNR concentration, sample volume, phantom geometry, and amplitude of optoacoustic signals propagating along different directions; (b) echographic detection of "optoacoustic spots," analyzing their intensity, spatial distribution, and clinical exploitability. MTT measurements performed on two different cell lines were also used to quantify biocompatibility of the synthesized GNRs in the adopted doses. Laser irradiation at 30 mJ/cm(2) for 20 seconds resulted in the best compromise among the requirements of effectiveness, safety, and nanoparticle stability. Amplitude of GNR-emitted optoacoustic pulses was proportional to both sample volume and concentration along each considered propagation direction for all the tested boundary conditions, providing an experimental confirmation of isotropic optoacoustic emission. Average intensity of echographically detected spots showed similar behavior, emphasizing the presence of an "ideal" GNR concentration (100 pM) that optimized optoacoustic effectiveness. The tested GNRs also exhibited high biocompatibility over the entire considered

  5. Helium concentration in tungsten nano-tendril surface morphology using Elastic Recoil Detection

    International Nuclear Information System (INIS)

    Woller, K.B.; Whyte, D.G.; Wright, G.M.; Doerner, R.P.; De Temmerman, G.

    2013-01-01

    Helium (He) concentrations in tungsten nano-tendrils (W fuzz) have been measured for the first time using Elastic Recoil Detection (ERD). Fuzzy and non-fuzzy W surfaces were analyzed in order to illuminate the role of He in the transition in surface morphologies. Samples grown in the PISCES-A and PILOT-PSI experiments allowed a survey of surface temperature ranging from T s = 470–2595 K and of He fluence on the order of Φ He ∼ 10 24 –10 27 ions/m 2 . He concentrations measured in the bulk of W fuzz layers are roughly uniform with bulk He concentration 1–4 at.% while samples with just He in the near surface peaked at 1–2 at.%. This confirms that the nano-tendrils are filled with high pressure He bubbles since the solubility of He in W is ∼10 −5 at.%. This indicates that the ∼1000 K temperature fuzz-growth threshold is determined by the response of the W, not the near-surface He concentration

  6. Modified graphene oxide sensors for ultra-sensitive detection of nitrate ions in water.

    Science.gov (United States)

    Ren, Wen; Mura, Stefania; Irudayaraj, Joseph M K

    2015-10-01

    Nitrate ions is a very common contaminant in drinking water and has a significant impact on the environment, necessitating routine monitoring. Due to its chemical and physical properties, it is hard to directly detect nitrate ions with high sensitivity in a simple and inexpensive manner. Herein with amino group modified graphene oxide (GO) as a sensing element, we show a direct and ultra-sensitive method to detect nitrate ions, at a lowest detected concentration of 5 nM in river water samples, much lower than the reported methods based on absorption spectroscopy. Furthermore, unlike the reported strategies based on absorption spectroscopy wherein the nitrate concentration is determined by monitoring an increase in aggregation of gold nanoparticles (GNPs), our method evaluates the concentration of nitrate ions based on reduction in aggregation of GNPs for monitoring in real samples. To improve sensitivity, several optimizations were performed, including the assessment of the amount of modified GO required, concentration of GNPs and incubation time. The detection methodology was characterized by zeta potential, TEM and SEM. Our results indicate that an enrichment of modified GO with nitrate ions contributed to excellent sensitivity and the entire detection procedure could be completed within 75 min with only 20 μl of sample. This simple and rapid methodology was applied to monitor nitrate ions in real samples with excellent sensitivity and minimum pretreatment. The proposed approach paves the way for a novel means to detect anions in real samples and highlights the potential of GO based detection strategy for water quality monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Preparations for an optical access to the lowest nuclear excitation in {sup 229}Th

    Energy Technology Data Exchange (ETDEWEB)

    Wense, Lars v.d.; Seiferle, Benedict; Thirolf, Peter [Ludwig-Maximilians-Universitaet Muenchen (Germany); Laatiaoui, Mustapha [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany)

    2014-07-01

    The isomeric lowest excited nuclear level of {sup 229}Th has been indirectly measured to be 7.6±0.5 eV (163±11 nm). In order to improve the accuracy as prerequisite of an all-optical control, {sup 229m}Th is populated via a 2% decay branch in the α decay of {sup 233}U. The Thorium ions are extracted and cooled with the help of a buffer gas stopping cell and an RFQ-cooler. In order to suppress accompanying α decay chain products other than {sup 229}Th, a quadrupole mass spectrometer (QMS) is used, performance and extraction efficiency measurements were performed. Following the QMS, the Thorium isomers will be collected on a 50 μm micro electrode. The decay of these isomers can then be detected using deep UV optics, presently in the phase of preparation and adjustment. Newest results are presented.

  8. Proposal for a methodology for the determination of the Detection Limit: Case of bulks detector for the Chlorothalonil

    International Nuclear Information System (INIS)

    Gonzalez G, J.; Parra M, C.M.; Romero R, R.M.

    1998-01-01

    As it usually found in the literature, the Lower Detection Limit for an analytical method is obtained by means of a simple statistical exercise whose value is seldom attained in practice. For this reason a method was designed for achieving a Practical Lower Detection Limit for the lowest concentration of the compound that could be detected, S= 2 R, with a probability of at least, 0.90. A methodological design was formulated to get a Practical Lower Detection Limit that is not timed consuming for the analyst. It is presented using an example and, additionally its benefits are discussed versus the unattainable values that are obtained by the traditional use of the standard deviation of a series of measurements of the compound at concentrations near zero, which is then multiplied by the t student for a one tailed test for n-1 degrees of freedom

  9. Detection of Adriamycin-DNA adducts by accelerator mass spectrometry at clinically relevant Adriamycin concentrations.

    Science.gov (United States)

    Coldwell, Kate E; Cutts, Suzanne M; Ognibene, Ted J; Henderson, Paul T; Phillips, Don R

    2008-09-01

    Limited sensitivity of existing assays has prevented investigation of whether Adriamycin-DNA adducts are involved in the anti-tumour potential of Adriamycin. Previous detection has achieved a sensitivity of a few Adriamycin-DNA adducts/10(4) bp DNA, but has required the use of supra-clinical drug concentrations. This work sought to measure Adriamycin-DNA adducts at sub-micromolar doses using accelerator mass spectrometry (AMS), a technique with origins in geochemistry for radiocarbon dating. We have used conditions previously validated (by less sensitive decay counting) to extract [(14)C]Adriamycin-DNA adducts from cells and adapted the methodology to AMS detection. Here we show the first direct evidence of Adriamycin-DNA adducts at clinically-relevant Adriamycin concentrations. [(14)C]Adriamycin treatment (25 nM) resulted in 4.4 +/- 1.0 adducts/10(7) bp ( approximately 1300 adducts/cell) in MCF-7 breast cancer cells, representing the best sensitivity and precision reported to date for the covalent binding of Adriamycin to DNA. The exceedingly sensitive nature of AMS has enabled over three orders of magnitude increased sensitivity of Adriamycin-DNA adduct detection and revealed adduct formation within an hour of drug treatment. This method has been shown to be highly reproducible for the measurement of Adriamycin-DNA adducts in tumour cells in culture and can now be applied to the detection of these adducts in human tissues.

  10. No detectable carotenoid concentrations in serum of llamas and alpacas.

    Science.gov (United States)

    Raila, J; Schweigert, F J; Stanitznig, A; Lambacher, B; Franz, S; Baldermann, S; Wittek, T

    2017-08-01

    Carotenoids are lipid-soluble pigments and important for a variety of physiological functions. They are major dietary vitamin A precursors and act as lipophilic antioxidants in a variety of tissues and are associated with important health benefits in humans and animals. All animals must acquire carotenoids from their diet, but to our knowledge, there are no studies investigating the intestinal carotenoid absorption and their blood concentrations in New World camelids. The present study aimed to assess the serum concentrations of selected carotenoids in llamas (n = 13) and alpacas (n = 27). Serum carotenoids as well as retinol (vitamin A) and α-tocopherol (vitamin E) were determined by high-performance liquid chromatography coupled with mass spectrometry and these were unable to detect any carotenoids (α- and β-carotene, α- and β-cryptoxanthin, lutein, zeaxanthin, lycopene) in the samples. The concentrations of retinol in alpacas (2.89 ± 1.13 μmol/l; mean ± SD) were higher (p = 0.024) than those found in llamas (2.05 ± 0.87 μmol/l); however, the concentrations of α-tocopherol were not significantly (p = 0.166) different (llamas: 3.98 ± 1.83 μmol/l; alpacas: 4.95 ± 2.14 μmol/l). The results show that both llamas and alpacas are not able to absorb intact carotenoids, but efficiently convert provitamin A carotenoids to retinol. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.

  11. Rationality, irrationality and escalating behavior in lowest unique bid auctions.

    Science.gov (United States)

    Radicchi, Filippo; Baronchelli, Andrea; Amaral, Luís A N

    2012-01-01

    Information technology has revolutionized the traditional structure of markets. The removal of geographical and time constraints has fostered the growth of online auction markets, which now include millions of economic agents worldwide and annual transaction volumes in the billions of dollars. Here, we analyze bid histories of a little studied type of online auctions--lowest unique bid auctions. Similarly to what has been reported for foraging animals searching for scarce food, we find that agents adopt Lévy flight search strategies in their exploration of "bid space". The Lévy regime, which is characterized by a power-law decaying probability distribution of step lengths, holds over nearly three orders of magnitude. We develop a quantitative model for lowest unique bid online auctions that reveals that agents use nearly optimal bidding strategies. However, agents participating in these auctions do not optimize their financial gain. Indeed, as long as there are many auction participants, a rational profit optimizing agent would choose not to participate in these auction markets.

  12. Detection system of capillary array electrophoresis microchip based on optical fiber

    Science.gov (United States)

    Yang, Xiaobo; Bai, Haiming; Yan, Weiping

    2009-11-01

    To meet the demands of the post-genomic era study and the large parallel detections of epidemic diseases and drug screening, the high throughput micro-fluidic detection system is needed urgently. A scanning laser induced fluorescence detection system based on optical fiber has been established by using a green laser diode double-pumped solid-state laser as excitation source. It includes laser induced fluorescence detection subsystem, capillary array electrophoresis micro-chip, channel identification unit and fluorescent signal processing subsystem. V-shaped detecting probe composed with two optical fibers for transmitting the excitation light and detecting induced fluorescence were constructed. Parallel four-channel signal analysis of capillary electrophoresis was performed on this system by using Rhodamine B as the sample. The distinction of different samples and separation of samples were achieved with the constructed detection system. The lowest detected concentration is 1×10-5 mol/L for Rhodamine B. The results show that the detection system possesses some advantages, such as compact structure, better stability and higher sensitivity, which are beneficial to the development of microminiaturization and integration of capillary array electrophoresis chip.

  13. Selectivity improvement of positive photoionization ion mobility spectrometry for rapid detection of organophosphorus pesticides by switching dopant concentration.

    Science.gov (United States)

    Zhou, Qinghua; Li, Jia; Wang, Bin; Wang, Shuang; Li, Haiyang; Chen, Jinyuan

    2018-01-01

    Ion mobility spectrometry (IMS) opened a potential avenue for the rapid detection of organophosphorus pesticides (OPPs), though an improved selectivity of stand-alone IMS was still in high demand. In this study, a stand-alone positive photoionization ion mobility spectrometry (PP-IMS) apparatus was constructed for the rapid detection of OPPs with acetone as dopant. The photoionization of acetone molecules was induced by the ultraviolet irradiation to produce the reactant ions (Ac) 2 H + , which were employed to ionize the OPPs including fenthion, imidan, phosphamidon, dursban, dimethoate and isocarbophos via the proton transfer reaction. Due to the difference in proton affinity, the tested OPPs exhibited the different dopant-dependent manners. Based on this observation, the switching of dopant concentration was implemented to improve the selectivity of PP-IMS for OPPs detection. For instance, a mixture of fenthion, dursban and dimethoate was tested. By switching the concentration of doped acetone from 0.07 to 2.33 to 19.94mgL -1 , the ion peaks of fenthion and dursban were inhibited in succession, achieving the selective detection of dimethoate at last. In addition, another mixture of imidan and phosphamidon was initially detected by PP-IMS with a dose of 0.07mgL -1 acetone, indicating that their ion peaks were severely overlapped; when the concentration of doped acetone was switched to 19.94mgL -1 , the inhibition of imidan signals promised the accurate identification of phosphamidon in mixture. Finally, the PP-IMS in combination of switching dopant concentration was applied to detect the mixed fenthion, dursban and dimethoate in Chinese cabbage, demonstrating the applicability of proposed method to real samples. Copyright © 2017. Published by Elsevier B.V.

  14. Enhancing reproducibility of SALDI MS detection by concentrating analytes within laser spot.

    Science.gov (United States)

    Teng, Fei; Zhu, Qunyan; Wang, Yalei; Du, Juan; Lu, Nan

    2018-03-01

    Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI TOF MS) has become one of the most important analytical methods due to its less interference at low molecular weight range. However, it is still a challenge to obtain a good reproducibility of SALDI TOF MS because of the inhomogeneous distribution of analyte molecules induced by coffee ring effect. We propose a universal and reliable method to eliminate the coffee ring effect by concentrating all the analyte molecules within the laser spot. This method exhibits an excellent reproducibility of spot-to-spot and substrate-to-substrate, and the relative standard deviations (RSDs) for different concentrations are lower than 12.6%. It also performs good linear dependency (R 2 > 0.98) in the log-log plot with the concentration range of 1nM to 1μM, and the limit of detection for R6G is down to 1fmol. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Multiple sensor integration for seizure onset detection in human patients comparing conventional disc versus novel tripolar concentric ring electrodes.

    Science.gov (United States)

    Makeyev, Oleksandr; Ding, Quan; Martínez-Juárez, Iris E; Gaitanis, John; Kay, Steven M; Besio, Walter G

    2013-01-01

    As epilepsy affects approximately one percent of the world population, electrical stimulation of the brain has recently shown potential for additive seizure control therapy. Closed-loop systems that apply electrical stimulation when seizure onset is automatically detected require high accuracy of automatic seizure detection based on electrographic brain activity. To improve this accuracy we propose to use noninvasive tripolar concentric ring electrodes that have been shown to have significantly better signal-to-noise ratio, spatial selectivity, and mutual information compared to conventional disc electrodes. The proposed detection methodology is based on integration of multiple sensors using exponentially embedded family (EEF). In this preliminary study it is validated on over 26.3 hours of data collected using both tripolar concentric ring and conventional disc electrodes concurrently each from 7 human patients with epilepsy including five seizures. For a cross-validation based group model EEF correctly detected 100% and 80% of seizures respectively with tripolar concentric ring electrodes.

  16. Detection of trace amount of arsenic in groundwater by laser-induced breakdown spectroscopy and adsorption

    Science.gov (United States)

    Haider, A. F. M. Y.; Hedayet Ullah, M.; Khan, Z. H.; Kabir, Firoza; Abedin, K. M.

    2014-03-01

    LIBS technique coupled with adsorption has been applied for the efficient detection of arsenic in liquid. Several adsorbents like tea leaves, bamboo slice, charcoal and zinc oxide have been used to enable sensitive detection of arsenic presence in water using LIBS. Among these, zinc oxide and charcoal show the better results. The detection limits for arsenic in water were 1 ppm and 8 ppm, respectively, when ZnO and charcoal were used as adsorbents of arsenic. To date, the determination of 1 ppm of As in water is the lowest concentration of detected arsenic in water by the LIBS technique. The detection limit of As was lowered to even less than 100 ppb by a combination of LIBS technique, adsorption by ZnO and concentration enhancement technique. Using the combination of these three techniques the ultimate concentration of arsenic was found to be 0.083 ppm (83 ppb) for arsenic polluted water collected from a tube-well of Farajikandi union (longitude 90.64°, latitude 23.338° north) of Matlab Upozila of Chandpur district in Bangladesh. This result compares fairly well with the finding of arsenic concentration of 0.078 ppm in the sample by the AAS technique at the Bangladesh Council of Scientific and Industrial Research (BCSIR) lab. Such a low detection limit (1 ppm) of trace elements in liquid matrix has significantly enhanced the scope of LIBS as an analytical tool.

  17. Ultrasensitive, highly selective, and real-time detection of protein using functionalized CNTs as MIP platform for FOSPR-based biosensor

    Science.gov (United States)

    Pathak, Anisha; Parveen, Shama; Gupta, Banshi D.

    2017-09-01

    A facile approach is presented for the detection of bovine serum albumin (BSA), based on fiber optic surface plasmon resonance (FOSPR) combined with molecular imprinting (MI). The probe is fabricated by exploiting the plasmonic property of silver thin film and vinyl-functionalised carbon nanotube-based MIP platform. BSA template molecules are imprinted on the MIP layer coated over multi-walled carbon nanotubes to ensure high specificity of the probe in the interfering environments. In addition, FOSPR endorses the sensor capability of real-time and remote sensing along with very high sensitivity due to the use of nanostructured MI platform. The response of the probe is considered in terms of the absorbance spectrum recorded for various concentrations of BSA. The sensor shows a wide dynamic range of 0-350 ng l-1 with a considerably linear response up to 100 ng l-1 in the peak absorbance wavelength with BSA concentration. A highest sensitivity of 0.862 nm per ng l-1 is achieved for the lowest concentration of BSA and it decreases with the increase in BSA concentration. The performance of the present sensor is compared with those reported in the literature in terms of the limit of detection. It is found that the probe possesses a lowest LOD of 0.386 ng l-1 in addition to other advantages such as real-time online monitoring, high sensitivity, high specificity, and remote sensing.

  18. Detecting and Identifying Industrial Gases by a Method Based on Olfactory Machine at Different Concentrations

    OpenAIRE

    Sun, Yunlong; Luo, Dehan; Li, Hui; Zhu, Chuchu; Xu, Ou; Gholam Hosseini, Hamid

    2018-01-01

    Gas sensors have been widely reported for industrial gas detection and monitoring. However, the rapid detection and identification of industrial gases are still a challenge. In this work, we measure four typical industrial gases including CO2, CH4, NH3, and volatile organic compounds (VOCs) based on electronic nose (EN) at different concentrations. To solve the problem of effective classification and identification of different industrial gases, we propose an algorithm based on the selective ...

  19. Rationality, irrationality and escalating behavior in lowest unique bid auctions.

    Directory of Open Access Journals (Sweden)

    Filippo Radicchi

    Full Text Available Information technology has revolutionized the traditional structure of markets. The removal of geographical and time constraints has fostered the growth of online auction markets, which now include millions of economic agents worldwide and annual transaction volumes in the billions of dollars. Here, we analyze bid histories of a little studied type of online auctions--lowest unique bid auctions. Similarly to what has been reported for foraging animals searching for scarce food, we find that agents adopt Lévy flight search strategies in their exploration of "bid space". The Lévy regime, which is characterized by a power-law decaying probability distribution of step lengths, holds over nearly three orders of magnitude. We develop a quantitative model for lowest unique bid online auctions that reveals that agents use nearly optimal bidding strategies. However, agents participating in these auctions do not optimize their financial gain. Indeed, as long as there are many auction participants, a rational profit optimizing agent would choose not to participate in these auction markets.

  20. Rationality, Irrationality and Escalating Behavior in Lowest Unique Bid Auctions

    Science.gov (United States)

    Radicchi, Filippo; Baronchelli, Andrea; Amaral, Luís A. N.

    2012-01-01

    Information technology has revolutionized the traditional structure of markets. The removal of geographical and time constraints has fostered the growth of online auction markets, which now include millions of economic agents worldwide and annual transaction volumes in the billions of dollars. Here, we analyze bid histories of a little studied type of online auctions – lowest unique bid auctions. Similarly to what has been reported for foraging animals searching for scarce food, we find that agents adopt Lévy flight search strategies in their exploration of “bid space”. The Lévy regime, which is characterized by a power-law decaying probability distribution of step lengths, holds over nearly three orders of magnitude. We develop a quantitative model for lowest unique bid online auctions that reveals that agents use nearly optimal bidding strategies. However, agents participating in these auctions do not optimize their financial gain. Indeed, as long as there are many auction participants, a rational profit optimizing agent would choose not to participate in these auction markets. PMID:22279553

  1. Concentrations of antibiotics predicted to select for resistant bacteria: Proposed limits for environmental regulation.

    Science.gov (United States)

    Bengtsson-Palme, Johan; Larsson, D G Joakim

    2016-01-01

    There are concerns that selection pressure from antibiotics in the environment may accelerate the evolution and dissemination of antibiotic-resistant pathogens. Nevertheless, there is currently no regulatory system that takes such risks into account. In part, this is due to limited knowledge of environmental concentrations that might exert selection for resistant bacteria. To experimentally determine minimal selective concentrations in complex microbial ecosystems for all antibiotics would involve considerable effort. In this work, our aim was to estimate upper boundaries for selective concentrations for all common antibiotics, based on the assumption that selective concentrations a priori need to be lower than those completely inhibiting growth. Data on Minimal Inhibitory Concentrations (MICs) were obtained for 111 antibiotics from the public EUCAST database. The 1% lowest observed MICs were identified, and to compensate for limited species coverage, predicted lowest MICs adjusted for the number of tested species were extrapolated through modeling. Predicted No Effect Concentrations (PNECs) for resistance selection were then assessed using an assessment factor of 10 to account for differences between MICs and minimal selective concentrations. The resulting PNECs ranged from 8 ng/L to 64 μg/L. Furthermore, the link between taxonomic similarity between species and lowest MIC was weak. This work provides estimated upper boundaries for selective concentrations (lowest MICs) and PNECs for resistance selection for all common antibiotics. In most cases, PNECs for selection of resistance were below available PNECs for ecotoxicological effects. The generated PNECs can guide implementation of compound-specific emission limits that take into account risks for resistance promotion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Behavior toxicity to Caenorhabditis elegans transferred to the progeny after exposure to sulfamethoxazole at environmentally relevant concentrations

    Institute of Scientific and Technical Information of China (English)

    Zhenyang Yu; Lei Jiang; Daqiang Yin

    2011-01-01

    Sulfamethoxazole (SMX) is one of the most common detected antibiotics in the environment. In order to study whether SMX can affect behavior and growth and whether these effects could be transferred to the progeny, Caenorhabditis elegans was exposed at environmentally relevant concentrations for 24, 48, 72 and 96 hr, respectively. After exposure, the exposed parent generation (Po) was measured for behavior and growth indicators, which were presented as percentage of controls (POC). Then their corresponding unexposed progeny (F1) was separated and measured for the same indicators. The lowest POC for Po after 96 hr-exposure at 100 mg/L were 37.8%, 12.7%, 45.8% and 70.1% for body bending frequency (BBF), reversal movement (RM), Omega turns (OT) and body length (BL), respectively. And F1 suffered defects with the lowest POC as 55.8%, 24.1%, 48.5% and 60.7% for BBF, RM, OT and BL, respectively. Defects in both Po and F1 showed a time- and concentration-dependent fashion and behavior indicators showed better sensitivity than growth indicator. The observed effects on F1 demonstrated the transferable properties of SMX. Defects of SMX at environmental concentrations suggested that it is necessary to perform further systematical studies on its ecological risk in actual conditions.

  3. An electron microscopy based method for the detection and quantification of nanomaterial number concentration in environmentally relevant media

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, A. [School of Geography, Earth and Environmental Sciences, College of Life and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lead, J.R., E-mail: jlead@mailbox.sc.edu [School of Geography, Earth and Environmental Sciences, College of Life and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Center for Environmental Nanoscience and Risk, Department of Environmental Health Sciences, Arnold School of Public Health, University South Carolina, Columbia 29208, SC (United States); Baalousha, M., E-mail: mbaalous@mailbox.sc.edu [Center for Environmental Nanoscience and Risk, Department of Environmental Health Sciences, Arnold School of Public Health, University South Carolina, Columbia 29208, SC (United States)

    2015-12-15

    Improved detection and characterization of nanomaterials (NMs) in complex environmental media requires the development of novel sampling approaches to improve the detection limit to be close to environmentally realistic concentrations. Transmission electron microscopy (TEM) is an indispensable metrological tool in nanotechnology and environmental nanoscience due to its high spatial resolution and analytical capabilities when coupled to spectroscopic techniques. However, these capabilities are hampered by the conventional sample preparation methods, which suffer from low NM recovery. The current work presents a validated, fully quantitative sampling technique for TEM that overcomes conventional sample preparation shortcomings, and thus enables the use of TEM for measurement of particle number concentration and their detection in complex media at environmentally realistic concentrations. This sampling method is based on ultracentrifugation of NMs from suspension onto a poly-L-lysine (PLL) functionalized TEM grid, using active deposition (by ultracentrifugation) and retention (by PLL interactions with NM surface) of NMs on the substrate, enabling fully quantitative analysis. Similar analysis with AFM was satisfactory in simple media but the lack of chemical-selectivity of AFM limits its applicability for the detection of NMs in complex environmental samples. The sampling approach was validated using both citrate- and PVP-coated AuNMs in pure water, which demonstrated an even distribution of NM on the TEM grid and high NM recovery (80–100%) at environmentally relevant NM concentrations (ca. 0.20–100 μg L{sup −1}). The applicability of the sampling method to complex environmental samples was demonstrated by the quantification of particle number concentration of AuNMs in EPA soft water (with and without Suwannee River fulvic acid) and lake water. This sample preparation approach is also applicable to other types of NMs with some modifications (e.g. centrifugation

  4. An electron microscopy based method for the detection and quantification of nanomaterial number concentration in environmentally relevant media

    International Nuclear Information System (INIS)

    Prasad, A.; Lead, J.R.; Baalousha, M.

    2015-01-01

    Improved detection and characterization of nanomaterials (NMs) in complex environmental media requires the development of novel sampling approaches to improve the detection limit to be close to environmentally realistic concentrations. Transmission electron microscopy (TEM) is an indispensable metrological tool in nanotechnology and environmental nanoscience due to its high spatial resolution and analytical capabilities when coupled to spectroscopic techniques. However, these capabilities are hampered by the conventional sample preparation methods, which suffer from low NM recovery. The current work presents a validated, fully quantitative sampling technique for TEM that overcomes conventional sample preparation shortcomings, and thus enables the use of TEM for measurement of particle number concentration and their detection in complex media at environmentally realistic concentrations. This sampling method is based on ultracentrifugation of NMs from suspension onto a poly-L-lysine (PLL) functionalized TEM grid, using active deposition (by ultracentrifugation) and retention (by PLL interactions with NM surface) of NMs on the substrate, enabling fully quantitative analysis. Similar analysis with AFM was satisfactory in simple media but the lack of chemical-selectivity of AFM limits its applicability for the detection of NMs in complex environmental samples. The sampling approach was validated using both citrate- and PVP-coated AuNMs in pure water, which demonstrated an even distribution of NM on the TEM grid and high NM recovery (80–100%) at environmentally relevant NM concentrations (ca. 0.20–100 μg L"−"1). The applicability of the sampling method to complex environmental samples was demonstrated by the quantification of particle number concentration of AuNMs in EPA soft water (with and without Suwannee River fulvic acid) and lake water. This sample preparation approach is also applicable to other types of NMs with some modifications (e.g. centrifugation

  5. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  6. Total protein and cholesterol concentrations in brain regions of male ...

    African Journals Online (AJOL)

    The results showed similarities (P>0.05) between the treatments in total protein concentrations in the cerebral cortex, medulla, hypothalamus, amygdala, mesencephalon and hippocampus. Total protein concentrations however differed significantly between diets (P<0.05) in the cerebellum and pons varoli with the lowest ...

  7. Optimizing Taq polymerase concentration for improved signal-to-noise in the broad range detection of low abundance bacteria.

    Directory of Open Access Journals (Sweden)

    Rudolph Spangler

    Full Text Available BACKGROUND: PCR in principle can detect a single target molecule in a reaction mixture. Contaminating bacterial DNA in reagents creates a practical limit on the use of PCR to detect dilute bacterial DNA in environmental or public health samples. The most pernicious source of contamination is microbial DNA in DNA polymerase preparations. Importantly, all commercial Taq polymerase preparations inevitably contain contaminating microbial DNA. Removal of DNA from an enzyme preparation is problematical. METHODOLOGY/PRINCIPAL FINDINGS: This report demonstrates that the background of contaminating DNA detected by quantitative PCR with broad host range primers can be decreased greater than 10-fold through the simple expedient of Taq enzyme dilution, without altering detection of target microbes in samples. The general method is: For any thermostable polymerase used for high-sensitivity detection, do a dilution series of the polymerase crossed with a dilution series of DNA or bacteria that work well with the test primers. For further work use the concentration of polymerase that gave the least signal in its negative control (H(2O while also not changing the threshold cycle for dilutions of spiked DNA or bacteria compared to higher concentrations of Taq polymerase. CONCLUSIONS/SIGNIFICANCE: It is clear from the studies shown in this report that a straightforward procedure of optimizing the Taq polymerase concentration achieved "treatment-free" attenuation of interference by contaminating bacterial DNA in Taq polymerase preparations. This procedure should facilitate detection and quantification with broad host range primers of a small number of bona fide bacteria (as few as one in a sample.

  8. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  9. Neonatal thyroid-stimulating hormone concentrations in Belgium: a useful indicator for detecting mild iodine deficiency?

    Directory of Open Access Journals (Sweden)

    Stefanie Vandevijvere

    Full Text Available It has been proposed that neonatal thyroid-stimulating hormone (TSH concentrations are a good indicator of iodine deficiency in the population. A frequency of neonatal TSH concentrations above 5 mU/L below 3% has been proposed as the threshold indicating iodine sufficiency. The objective of the present study was to evaluate feasibility and usefulness of nation-wide neonatal TSH concentration screening results to assess iodine status in Belgium. All newborns born in Belgium during the period 2009-2011 (n = 377713 were included in the study, except those suffering from congenital hypothyroidism and premature neonates. The frequency of neonatal TSH concentrations above 5 mU/L from 2009 to 2011 in Belgium fluctuated between 2.6 and 3.3% in the centres using the same TSH assay. There was a significant inverse association between neonatal TSH level and birth weight. The longer the duration between birth and screening, the lower the TSH level. Neonatal TSH levels were significantly lower in winter than in spring or autumn and significantly lower in spring and summer than in autumn while significantly higher in spring compared to summer. In conclusion, despite that pregnant women in Belgium are mildly iodine deficient, the frequency of neonatal TSH concentrations above 5 mU/L was very low, suggesting that the neonatal TSH threshold proposed for detecting iodine deficiency needs to be re-evaluated. Although neonatal TSH is useful to detect severe iodine deficiency, it should not be recommended presently for the evaluation of iodine status in mildly iodine deficient regions.

  10. Fine structure of the lowest Landau level in suspended trilayer graphene

    NARCIS (Netherlands)

    van Elferen, H. J.; Veligura, A.; Tombros, N.; Kurganova, E. V.; van Wees, B. J.; Maan, J. C.; Zeitler, U.

    2013-01-01

    Magnetotransport experiments on ABC-stacked suspended trilayer graphene reveal a complete splitting of the 12-fold degenerated lowest Landau level, and, in particular, the opening of an exchange-driven gap at the charge neutrality point. A quantitative analysis of distinctness of the quantum Hall

  11. Rapid detection of chlorpyrifos pesticide residue concentration in agro-product using Raman spectroscopy

    Science.gov (United States)

    Dhakal, Sagar; Peng, Yankun; Li, Yongyu; Chao, Kuanglin; Qin, Jianwei; Zhang, Leilei; Xu, Tianfeng

    2014-05-01

    Different chemicals are sprayed in fruits and vegetables before and after harvest for better yield and longer shelf-life of crops. Cases of pesticide poisoning to human health are regularly reported due to excessive application of such chemicals for greater economic benefit. Different analytical technologies exist to detect trace amount of pesticides in fruits and vegetables, but are expensive, sample destructive, and require longer processing time. This study explores the application of Raman spectroscopy for rapid and non-destructive detection of pesticide residue in agricultural products. Raman spectroscopy with laser module of 785 nm was used to collect Raman spectral information from the surface of Gala apples contaminated with different concentrations of commercially available organophosphorous (48% chlorpyrifos) pesticide. Apples within 15 days of harvest from same orchard were used in this study. The Raman spectral signal was processed by Savitzky-Golay (SG) filter for noise removal, Multiplicative Scatter Correction (MSC) for drift removal and finally polynomial fitting was used to eliminate the fluorescence background. The Raman spectral peak at 677 cm-1 was recognized as Raman fingerprint of chlorpyrifos. Presence of Raman peak at 677 cm-1 after fluorescence background removal was used to develop classification model (presence and absence of pesticide). The peak intensity was correlated with actual pesticide concentration obtained using Gas Chromatography and MLR prediction model was developed with correlation coefficient of calibration and validation of 0.86 and 0.81 respectively. Result shows that Raman spectroscopy is a promising tool for rapid, real-time and non-destructive detection of pesticide residue in agro-products.

  12. Study of dielectric properties of adulterated milk concentration and freshness

    Science.gov (United States)

    Jitendra Murthy, V.; Sai Kiranmai, N.; Kumar, Sanjeev

    2017-08-01

    The knowledge of dielectric properties may hold a potential to develop a new technique for quality evaluation of milk. The dielectric properties of water diluted cow’s milk with milk concentration from 70 percent to 100 percent stored during 36hour storage at 22°C and 144 hour at 5°C were measured at room temperature for frequencies ranging from 10 to 4500 MHz and at low, high & at microwave frequencies using X band bench and open-ended coaxial-line probe technology, along with electrical conductivity. The raw milk had the lowest dielectric constant (ɛ‧) when the frequency was higher than about 20M.Hz, and had the highest loss (ɛ″) or decepation factor tan (δ) at each frequency. The penetration depth (dp) increased with decreasing frequency, water content and storage time, which was large enough to detect dielectric properties changes in milk samples and provide large scale RF pasteurization processes. The loss factor can be an indicator in predicting milk concentration and freshness.

  13. Chern-Simons field theory of two-dimensional electrons in the lowest Landau level

    International Nuclear Information System (INIS)

    Zhang, L.

    1996-01-01

    We propose a fermion Chern-Simons field theory describing two-dimensional electrons in the lowest Landau level. This theory is constructed with a complete set of states, and the lowest-Landau-level constraint is enforced through a δ functional described by an auxiliary field λ. Unlike the field theory constructed directly with the states in the lowest Landau level, this theory allows one, utilizing the physical picture of open-quote open-quote composite fermion,close-quote close-quote to study the fractional quantum Hall states by mapping them onto certain integer quantum Hall states; but, unlike its application in the unconstrained theory, such a mapping is sensible only when interactions between electrons are present. An open-quote open-quote effective mass,close-quote close-quote which characterizes the scale of low energy excitations in the fractional quantum Hall systems, emerges naturally from our theory. We study a Gaussian effective theory and interpret physically the dressed stationary point equation for λ as an equation for the open-quote open-quote mass renormalization close-quote close-quote of composite fermions. copyright 1996 The American Physical Society

  14. Search for the lowest irradiation dose from literatures on radiation-induced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T [Tokyo Univ. (Japan). Faculty of Medicine

    1975-12-01

    A survey of past case reports concerning radiation-induced breast cancer was carried out in order to find the lowest irradiation dose. The search of literature published since 1951 revealed 10 cases of radiation-induced breast cancer. Only 5 cases had precise descriptions of the irradiation dose. The lowest irradiation dose was estimated at 1470 rads in the case of external X-ray irradiation for tuberous angioma. All of cases of radiation-induced breast cancer had received radiation for the treatment of nonmalignant tumors, such as pulmonary tuberculosis, mastitis, and tuberous angioma. There also were three statistical studies. The first concerned atomic bomb survivors, the second, pulmoanry tuberculous patients subjected to frequent fluoroscopies, and the third, patients of acute post partum mastitis. These statistical studies had revealed a significant increase in the incidence of breast cancer in the irradiated group, but there was little information about the lowest irradiation dose. It was noticed that radiation-induced breast cancer was more numerous in the upper inner quadrant of the breast. Most histopathological findings of radiation-induced breast cancer involved duct cell carcinoma. The latent period was about 15 years.

  15. Micro-evaporation electrolyte concentrator

    NARCIS (Netherlands)

    Timmer, B.H.; van Delft, K.M.; Olthuis, Wouter; Bergveld, Piet; van den Berg, Albert

    2003-01-01

    The sensitivity of miniaturized chemical analysis systems depends most of the time on the obtainable detection limit. Concentrating the analyte prior to the detection system can enhance the detection limit. In this writing an analyte concentrator is presented that makes use of evaporation to

  16. Composition and Concentration of Phenolic Compounds of ‘Auksis’ Apple Grown on Various Rootstocks

    Directory of Open Access Journals (Sweden)

    Kviklys Darius

    2017-06-01

    Full Text Available The trial was carried out at the Institute of Horticulture, Lithuanian Research Centre for Agriculture and Forestry in 2013-2015. Cv. ‘Auksis’ was tested on 12 rootstocks: B.396, B.9, M.9, M.26, P 22, P 59, P 61, P 62, P 66, P 67, PB.4, and Pure 1. Accumulation of phenolic compounds depended on fruit yield and average fruit weight. On average, significantly lower concentration among rootstocks occurred when apple trees had abundant yield and fruits were smaller. On average chlorogenic acid constituted 50% and total procyanidins 28% of total phenols in ‘Auksis’ fruits. Flavonoid concentration most depended on rootstock and the highest variation was recorded. More than 50% difference occurred between the highest total flavonoid concentration in apples on PB.4 and the lowest on M.9 rootstocks. Low variability of total procyanidin concentration among rootstocks was observed. Differences between the highest and lowest concentration was 15%. Total concentration of phenolic compounds differed among rootstocks by 29-35% depending on the year. Differences in accumulation of phenolic compounds depended on rootstock genotype but not on yield or fruit weight. PB.4 and P 67 rootstocks had the highest, and M.9, P 62 and M.26 had the lowest concentration of total phenol in ‘Auksis’ fruits

  17. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    Science.gov (United States)

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Effect of sampling site, repeated sampling, pH, and PCO2 on plasma lactate concentration in healthy dogs.

    Science.gov (United States)

    Hughes, D; Rozanski, E R; Shofer, F S; Laster, L L; Drobatz, K J

    1999-04-01

    To characterize the variation in plasma lactate concentration among samples from commonly used blood sampling sites in conscious, healthy dogs. 60 healthy dogs. Cross-sectional study using a replicated Latin square design. Each dog was assigned to 1 of 6 groups (n = 10) representing all possible orders for 3 sites (cephalic vein, jugular vein, and femoral artery) used to obtain blood. Samples were analyzed immediately, by use of direct amperometry for pH, PO2, Pco2, glucose, and lactate concentration. Significant differences in plasma lactate concentrations were detected among blood samples from the cephalic vein (highest), femoral artery, and jugular vein (lowest). Mean plasma lactate concentration in the first sample obtained, irrespective of sampling site, was lower than in subsequent samples. Covariation was identified among plasma lactate concentration, pH, and PCO2, but correlation coefficients were low. Plasma lactate concentrations differed among blood samples from various sites. A reference range for plasma lactate concentration was 0.3 to 2.5 mmol/L. Differences in plasma lactate concentrations among samples from various sites and with repeated sampling, in healthy dogs, are small. Use of the reference range may facilitate the clinical use of plasma lactate concentration in dogs.

  19. A cut-off in ocular chemesthesis from vapors of homologous alkylbenzenes and 2-ketones as revealed by concentration-detection functions

    International Nuclear Information System (INIS)

    Cometto-Muniz, J. Enrique; Abraham, Michael H.

    2008-01-01

    Studies of homologous series of environmental vapors have shown that their chemesthetic (i.e., sensory irritation) potency increases with carbon chain length (that is, their detection thresholds decrease) until they reach a homolog that fails to be detected, even at vapor saturation. All ensuing homologs cannot be detected either. In this investigation, we measured concentration-detection (i.e., psychometric) functions for ocular chemesthesis from homologous alkylbenzenes (pentyl, hexyl, and heptyl benzene) and 2-ketones (undecanone, dodecanone, and tridecanone). Using a three-alternative forced-choice procedure against air blanks, we tested a total of 18 to 24 subjects, about half of them females, average age 31 years, ranging from 18 to 56 years. Stimuli were generated and presented by a computer-controlled, vapor delivery device whose output was quantified by gas chromatography. Exposure time was 6 s and delivery flow 2.5 L/min. Within the context of present and previous findings, the outcome indicated that the functions for heptylbenzene and 2-tridecanone reached a plateau where further increases in concentration did not enhance detection. We conclude that: a) a cut-off point in ocular chemesthetic detection is reached along homologous alkylbenzenes and 2-ketones at the level of heptylbenzene and 2-tridecanone, respectively, and b) the observed effect rests on the homologs exceeding a critical molecular size (or dimension) rather than on them failing to achieve a high enough vapor concentration

  20. Synthesis, characterization and use of Ru-Fc intercalation complex as an electrochemical label for the detection of pathogen-DNA

    International Nuclear Information System (INIS)

    Díaz-Serrano, M; Rosado, A; Guadalupe, A R; Santana, D; Vega, E Z

    2013-01-01

    This report describes the synthesis of [Ru(Fe-Phen) 2 dppz](PF 6 ) 2 (Ru-Fe complex) for a label-free approach to detect DNA hybridization. The Ru-Fe complex showed oxidation signals at +608 mV and +1192 mV corresponding to the RuII/III and FeII/III centers, respectively. We used the Ru-Fe complex and the Ferrocene covalently attached to the target to monitor the hybridization event of a 70-mer oligo immobilized in 10.3KD NHS-PS-NHS. The lowest target detectable concentration for the DNA fragment was around 0.4 μM.

  1. [PM₂.₅ Background Concentration at Different Directions in Beijing in 2013].

    Science.gov (United States)

    Li, Yun-ting; Cheng, Niam-liang; Zhang, Da-wei; Sun, Rui-wen; Dong, Xin; Sun, Nai-di; Chen, Chen

    2015-12-01

    PM₂.₅, background concentration at different directions in 2013 in Beijing was analyzed combining the techniques of mathematical statistics, physical identification and numerical simulation (CMAQ4.7.1) as well as using monitoring data of six PM₂.₅ auto-monitoring sites and five meteorological sites in 2013. Results showed that background concentrations of PM₂.₅ at northwest, northeast, eastern, southeast, southern and southwest boundary sites were between 40.3 and 85.3 µg · m⁻³ in Beijing. From the lowest to the highest, PMPM₂.₅ background concentrations at different sites were: Miyun reservoir, Badaling, Donggaocun, Yufa, Yongledian and Liulihe. Background concentration of PM₂.₅ was the lowest under north wind, then under west wind, and significantly higher under south and east wind. Calculated PM₂.₅ background average concentrations were 6.5-27.9, 22.4-73.4, 67.2-91.7, 40.7-116.1 µg · m⁻³ respectively in different wind directions. Simulated PM₂.₅ background concentration showed a clear north-south gradient distribution and the surrounding area had a notable effect on the spatial distribution of PM₂.₅ background concentration in 2013 in Beijing.

  2. Optical characterization of nonimaging dish concentrator for the application of dense-array concentrator photovoltaic system.

    Science.gov (United States)

    Tan, Ming-Hui; Chong, Kok-Keong; Wong, Chee-Woon

    2014-01-20

    Optimization of the design of a nonimaging dish concentrator (NIDC) for a dense-array concentrator photovoltaic system is presented. A new algorithm has been developed to determine configuration of facet mirrors in a NIDC. Analytical formulas were derived to analyze the optical performance of a NIDC and then compared with a simulated result obtained from a numerical method. Comprehensive analysis of optical performance via analytical method has been carried out based on facet dimension and focal distance of the concentrator with a total reflective area of 120 m2. The result shows that a facet dimension of 49.8 cm, focal distance of 8 m, and solar concentration ratio of 411.8 suns is the most optimized design for the lowest cost-per-output power, which is US$1.93 per watt.

  3. Concentration of 210Po in cigars

    International Nuclear Information System (INIS)

    Kelecom, Alphonse; Gouvea, Rita C.S.; Santos, Pedro L.

    2000-01-01

    210 Po concentrations have been determined in 57 different cigar brands manufactured in 11 countries. Cuban and American cigars showed the lowest 210 Po content. The mean levels of 210 Po in Brazilian cigars were almost equal to those of European and Dominican cigars, and somewhat lower than cigars from Central American countries. (author)

  4. Echographic detectability of optoacoustic signals from low-concentration PEG-coated gold nanorods

    Directory of Open Access Journals (Sweden)

    Conversano F

    2012-08-01

    Full Text Available Francesco Conversano,1 Giulia Soloperto,1 Antonio Greco,1 Andrea Ragusa,1,2 Ernesto Casciaro,1 Fernanda Chiriacò,1 Christian Demitri,3 Giuseppe Gigli,2–5 Alfonso Maffezzoli,3 Sergio Casciaro11National Research Council, Institute of Clinical Physiology, Lecce, Italy; 2National Nanotechnology Laboratory of CNR-NANO, Lecce, Italy; 3University of Salento, Department of Engineering for Innovation, Lecce, Italy; 4Italian Institute of Technology – Center for Biomolecular Nanotechnology (CBN-IIT, Arnesano, Italy; 5University of Salento, Department of Mathematics and Physics ‘Ennio De Giorgi’, Lecce, ItalyPurpose: To evaluate the diagnostic performance of gold nanorod (GNR-enhanced optoacoustic imaging employing a conventional echographic device and to determine the most effective operative configuration in order to assure optoacoustic effectiveness, nanoparticle stability, and imaging procedure safety.Methods: The most suitable laser parameters were experimentally determined in order to assure nanoparticle stability during the optoacoustic imaging procedures. The selected configuration was then applied to a novel tissue-mimicking phantom, in which GNR solutions covering a wide range of low concentrations (25–200 pM and different sample volumes (50–200 µL were exposed to pulsed laser irradiation. GNR-emitted optoacoustic signals were acquired either by a couple of single-element ultrasound probes or by an echographic transducer. Off-line analysis included: (a quantitative evaluation of the relationships between GNR concentration, sample volume, phantom geometry, and amplitude of optoacoustic signals propagating along different directions; (b echographic detection of “optoacoustic spots,” analyzing their intensity, spatial distribution, and clinical exploitability. MTT measurements performed on two different cell lines were also used to quantify biocompatibility of the synthesized GNRs in the adopted doses.Results: Laser irradiation at

  5. Detection of low-concentration ammonia using differential laser-induced fluorescence on vapochromic coordination polymers

    Science.gov (United States)

    Yin, Dawei; Chapman, Glenn H.; Stevens, David; Gray, Bonnie; Leznoff, Daniel

    2018-02-01

    The detection of ammonia in parts per millions range has been challenging in sensors research, and is of great importance for industrial applications. In previous literature, Vapochromic Coordination Polymers (VCP) were developed to achieve luminescence upon a targeted gas exposures. We investigate a specific VCP, Zn[Au(CN)2]2,as an ammonia sensing material. Upon high concentration ammonia exposure, the fluorescent peak under near-UV stimulation undergoes a spectral shift from 460nm to 520nm, while the intensity increases by 3 4X. However, at ammonia concentrations portable spectrometer (Photon Control SPM-002), and processed the data by separating the spectrum into two regions; (A) from 425 nm to 460 nm and (B) from 460nm to 500nm. Next, the integrated emissions under both regions were computed, and the value of shorter wavelength region (A) was subtracted from the longer wavelength one (B). When exposed to ammonia, region (A) reduces overall intensity while region (B) increases, resulting a signal starting from negative value and gradually increases to positive values, enabling the detection of 5ppm ammonia in less than 30 seconds gas exposure.

  6. The activity concentration of radiocesium in mushrooms from locality Stare Ransko

    International Nuclear Information System (INIS)

    Kunova, V.; Dvorak, P.; Benova, K.

    2006-01-01

    In this paper, activity concentrations of radiocesium in mushrooms from Stare Ransko (Czech Republic) in the years 2003 - 2004 are presented. The highest activity concentrations of 137 Cs measured by gamma-spectrometry was 6 040 Bq/kg (on a dry mass basis) in Xerocomus badius. The lowest activity concentration of 137 Cs was < 2.4 Bq/kg in Lycoperdon perlatum. (authors)

  7. Development of an aptamer-based concentration method for the detection of Trypanosoma cruzi in blood.

    Directory of Open Access Journals (Sweden)

    Rana Nagarkatti

    Full Text Available Trypanosoma cruzi, a blood-borne parasite, is the etiological agent of Chagas disease. T. cruzi trypomastigotes, the infectious life cycle stage, can be detected in blood of infected individuals using PCR-based methods. However, soon after a natural infection, or during the chronic phase of Chagas disease, the number of parasites in blood may be very low and thus difficult to detect by PCR. To facilitate PCR-based detection methods, a parasite concentration approach was explored. A whole cell SELEX strategy was utilized to develop serum stable RNA aptamers that bind to live T. cruzi trypomastigotes. These aptamers bound to the parasite with high affinities (8-25 nM range. The highest affinity aptamer, Apt68, also demonstrated high specificity as it did not interact with the insect stage epimastigotes of T. cruzi nor with other related trypanosomatid parasites, L. donovani and T. brucei, suggesting that the target of Apt68 was expressed only on T. cruzi trypomastigotes. Biotinylated Apt68, immobilized on a solid phase, was able to capture live parasites. These captured parasites were visible microscopically, as large motile aggregates, formed when the aptamer coated paramagnetic beads bound to the surface of the trypomastigotes. Additionally, Apt68 was also able to capture and aggregate trypomastigotes from several isolates of the two major genotypes of the parasite. Using a magnet, these parasite-bead aggregates could be purified from parasite-spiked whole blood samples, even at concentrations as low as 5 parasites in 15 ml of whole blood, as detected by a real-time PCR assay. Our results show that aptamers can be used as pathogen specific ligands to capture and facilitate PCR-based detection of T. cruzi in blood.

  8. Determination of uranium in aqueous solutions by HPLC post column UV/VIS detection

    International Nuclear Information System (INIS)

    Abbasi, W.A.; Street, M.

    1995-01-01

    Analysis of uranium in different nitric acid concentration solutions is interest in nuclear industry where it is present in various process and waste streams. A method for the determination of uranium(VI) in nitric acid solution in described using ion chromatography and post-column derivatization with 4-(2-pyridylazo) resorcinol (PAR). The method does not require any sample treatment for acid removal or neutralization and can be used for routine laboratory analysis. The effluent used was ammonium sulphate / sulphuric acid and PAR was present in ammonium hydroxide/acetic acid buffer. The column effluents is reacted with PAR in a reaction coil and U(VI)-PAR complex is detector at 528 nm. The lowest uranium concentration detected was 100 ppb (0.1 mg/sup -1/) and linearity of up to 8 mgl -1 concentration was verified. The standard deviation in reproducibility at uranium concentration of 0.1 mgl/sup -1/ was 0.82%. (author)

  9. Facile preparation of a DNA sensor for rapid herpes virus detection

    Energy Technology Data Exchange (ETDEWEB)

    Tam, Phuong Dinh, E-mail: tampd-hast@mail.hut.edu.vn [Hanoi Advanced School of Science and Technology, Hanoi University of Technology (Viet Nam); Tuan, Mai Anh, E-mail: tuanma-itims@mail.hut.edu.vn [International Training Institute for Materials Science, Hanoi University of Technology (Viet Nam); Huy, Tran Quang [National Institute of Hygiene and Epidemiology (NIHE), 01 Yersin, Hai Ba Trung District, Hanoi (Viet Nam); Le, Anh-Tuan [Hanoi Advanced School of Science and Technology, Hanoi University of Technology (Viet Nam); Hieu, Nguyen Van, E-mail: hieu@itims.edu.vn [International Training Institute for Materials Science, Hanoi University of Technology (Viet Nam)

    2010-10-12

    In this paper, a simple DNA sensor platform was developed for rapid herpes virus detection in real samples. The deoxyribonucleic acid (DNA) sequences of the herpes simplex virus (DNA probe) were directly immobilized on the surface of interdigitated electrodes by electrochemical polymerization along with pyrrole monomers. The potential was scanned from - 0.7 to + 0.6 V, and the scanning rate was 100 mV/s. Fourier transform infrared spectroscopy was employed to verify specific DNA sequence binding and the conducting polymer. The morphology of the conducting polymer doped with DNA strands was characterized using a field emission scanning electron microscope. As-obtained DNA sensor was used to detect the herpes virus DNA in the real samples. The results show that the current DNA sensors detected the lowest DNA concentration of 2 nM. This sensitivity appears to be better than that of the DNA sensors prepared by immobilization of the DNA probe on the 3-aminopropyl-triethoxy-silance (APTS) membrane.

  10. Facile preparation of a DNA sensor for rapid herpes virus detection

    International Nuclear Information System (INIS)

    Tam, Phuong Dinh; Tuan, Mai Anh; Huy, Tran Quang; Le, Anh-Tuan; Hieu, Nguyen Van

    2010-01-01

    In this paper, a simple DNA sensor platform was developed for rapid herpes virus detection in real samples. The deoxyribonucleic acid (DNA) sequences of the herpes simplex virus (DNA probe) were directly immobilized on the surface of interdigitated electrodes by electrochemical polymerization along with pyrrole monomers. The potential was scanned from - 0.7 to + 0.6 V, and the scanning rate was 100 mV/s. Fourier transform infrared spectroscopy was employed to verify specific DNA sequence binding and the conducting polymer. The morphology of the conducting polymer doped with DNA strands was characterized using a field emission scanning electron microscope. As-obtained DNA sensor was used to detect the herpes virus DNA in the real samples. The results show that the current DNA sensors detected the lowest DNA concentration of 2 nM. This sensitivity appears to be better than that of the DNA sensors prepared by immobilization of the DNA probe on the 3-aminopropyl-triethoxy-silance (APTS) membrane.

  11. RED DWARF DYNAMO RAISES PUZZLE OVER INTERIORS OF LOWEST-MASS STARS

    Science.gov (United States)

    2002-01-01

    NASA's Hubble Space Telescope has uncovered surprising evidence that powerful magnetic fields might exist around the lowest mass stars in the universe, which are near the threshold of stellar burning processes. 'New theories will have to be developed to explain how these strong fields are produced, since conventional models predict that these low mass red dwarfs should have very weak or no magnetic fields,' says Dr. Jeffrey Linsky of the Joint Institute for Laboratory Astrophysics (JILA) in Boulder, Colorado. 'The Hubble observations provide clear evidence that very low mass red dwarf stars must have some form of dynamo to amplify their magnetic fields.' His conclusions are based upon Hubble's detection of a high-temperature outburst, called a flare, on the surface of the extremely small, cool red dwarf star Van Biesbroeck 10 (VB10) also known as Gliese 752B. Stellar flares are caused by intense, twisted magnetic fields that accelerate and contain gasses which are much hotter than a star's surface. Explosive flares are common on the Sun and expected for stars that have internal structures similar to our Sun's. Stars as small as VB10 are predicted to have a simpler internal structure than that of the Sun and so are not expected to generate the electric currents required for magnetic fields that drive flares. Besides leading to a clearer understanding of the interior structure of the smallest red dwarf stars known, these unexpected results might possibly shed light on brown dwarf stars. A brown dwarf is a long-sought class of astronomical object that is too small to shine like a star through nuclear fusion processes, but is too large to be considered a planet. 'Since VB10 is nearly a brown dwarf, it is likely brown dwarfs also have strong magnetic fields,' says Linsky. 'Additional Hubble searches for flares are needed to confirm this prediction.' A QUARTER-MILLION DEGREE TORCH The star VB10 and its companion star Gliese 752A make up a binary system located 19 light

  12. Network single-walled carbon nanotube biosensors for fast and highly sensitive detection of proteins

    International Nuclear Information System (INIS)

    Hu Pingan; Zhang Jia; Wen Zhenzhong; Zhang Can

    2011-01-01

    Detection of proteins is powerfully assayed in the diagnosis of diseases. A strategy for the development of an ultrahigh sensitivity biosensor based on a network single-walled carbon nanotube (SWNT) field-effect transistor (FET) has been demonstrated. Metallic SWNTs (m-SWNTs) in the network nanotube FET were selectively removed or cut via a carefully controlled procedure of electrical break-down (BD), and left non-conducting m-SWNTs which magnified the Schottky barrier (SB) area. This nanotube FET exhibited ultrahigh sensitivity and fast response to biomolecules. The lowest detection limit of 0.5 pM was achieved by exploiting streptavidin (SA) or a biotin/SA pair as the research model, and BD-treated nanotube biosensors had a 2 x 10 4 -fold lower minimum detectable concentration than the device without BD treatment. The response time is in the range of 0.3-3 min.

  13. A silicon-based electrochemical sensor for highly sensitive, specific, label-free and real-time DNA detection

    International Nuclear Information System (INIS)

    Guo, Yuanyuan; Su, Shao; Wei, Xinpan; Zhong, Yiling; Su, Yuanyuan; He, Yao; Huang, Qing; Fan, Chunhai

    2013-01-01

    We herein present a new kind of silicon-based electrochemical sensor using a gold nanoparticles-decorated silicon wafer (AuNPs@Si) as a high-performance electrode, which is facilely prepared via in situ AuNPs growth on a silicon wafer. Particularly significantly, the resultant electrochemical sensor is efficacious for label-free DNA detection with high sensitivity due to the unique merits of the prepared silicon-based electrode. Typically, DNA at remarkably low concentrations (1–10 fM) could be readily detected without requiring additional signal-amplification procedures, which is better than or comparable to the lowest DNA concentration ever detected via well-studied signal-amplification-assisted electrochemical sensors. Moreover, the silicon-based sensor features high specificity, allowing unambiguous discrimination of single-based mismatches. We further show that real-time DNA assembly is readily monitored via recording the intensity changes of current signals due to the robust thermal stability of the silicon-based electrode. The unprecedented advantages of the silicon-based electrochemical sensor would offer new opportunities for myriad sensing applications. (paper)

  14. Estimation of minimum detectable concentration of chlorine in the blast furnace slag cement concrete

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A., E-mail: aanaqvi@kfupm.edu.s [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Garwan, M.A.; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Khateeb-ur-Rehman,; Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2011-01-01

    The Prompt Gamma Neutron Activation Analysis technique was used to measure the concentration of chloride in the blast furnace slag (BFS) cement concrete to assess the possibility of reinforcement corrosion. The experimental setup was optimized using Monte Carlo calculations. The BFS concrete specimens containing 0.8-3.5 wt.% chloride were prepared and the concentration of chlorine was evaluated by determining the yield of 6.11, 6.62, 7.41, 7.79 and 8.58 MeV gamma-rays. The Minimum Detectable Concentration (MDC) of chlorine in the BFS cement concrete was estimated. The best value of MDC limit of chlorine in the BFS cement concrete was found to be 0.034 {+-} 0.011 and 0.038 {+-} 0.012 wt.% for 6.11 and 6.62 MeV prompt gamma-rays. Within the statistical uncertainty the lower bound of the measured MDC of chlorine in the BFS cement concrete meets the maximum permissible limit of 0.03 wt.% of chloride set by the American Concrete Institute.

  15. Bioconjugated fluorescent silica nanoparticles for the rapid detection of Entamoeba histolytica.

    Science.gov (United States)

    Hemadi, Ahmad; Ekrami, Alireza; Oormazdi, Hormozd; Meamar, Ahmad Reza; Akhlaghi, Lame; Samarbaf-Zadeh, Ali Reza; Razmjou, Elham

    2015-05-01

    Rapid detection of Entamoeba histolytica based on fluorescent silica nanoparticle (FSNP) indirect immunofluorescence microscopy was evaluated. Silica nanoparticles were synthesized using Stöber's method, with their surface activated to covalently bind to, and immobilize, protein A. For biolabeling, FSNP was added to conjugated E. histolytica trophozoites with monoclonal anti-E. histolytica IgG1 for microscopic observation of fluorescence. Fluorescent silica nanoparticle sensitivity was determined with axenically cultured E. histolytica serially diluted to seven concentrations. Specificity was evaluated using other intestinal protozoa. Fluorescent silica nanoparticles detected E. histolytica at the lowest tested concentration with no cross-reaction with Entamoeba dispar, Entamoeba moshkovskii, Blastocystis sp., or Giardia lamblia. Visualization of E. histolytica trophozoites with anti-E. histolytica antibody labeled with fluorescein isothiocyanate (FITC) was compared with that using anti-E. histolytica antibody bioconjugated FSNP. Although FITC and FSNP produced similar results, the amount of specific antibody required for FITC to induce fluorescence of similar intensity was fivefold that for FSNP. Fluorescent silica nanoparticles delivered a rapid, simple, cost-effective, and highly sensitive and specific method of detecting E. histolytica. Further study is needed before introducing FSNP for laboratory diagnosis of amoebiasis. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Trace element concentrations in barramundi (Lates calcarifer) collected along the coast of Vietnam

    International Nuclear Information System (INIS)

    Tu, Nguyen Phuc Cam; Ha, Nguyen Ngoc; Haruta, Shinsuke; Takeuchi, Ichiro

    2014-01-01

    Highlights: • We analyzed 23 trace elements in barramundi collected along the coast of Vietnam. • Isotope signatures (δ 15 N and δ 13 C) helped us track the feeding habitats of barramundi. • We found clear geographic zone-dependent differences for Mn, As, Sr and Tl. • Consumption of barramundi may be safe for Vietnamese people. - Abstract: We determined concentrations of 23 trace elements (TEs), and stable carbon and nitrogen isotope (δ 13 C and δ 15 N) signatures in barramundi (Lates calcarifer) specimens collected along the coast of Vietnam in the Northern (NCZ), Central (CCZ) and Southern (SCZ) zones in the period 2007–2010. A combination of δ 13 C and δ 15 N signatures provided insight into ontogenetic shifts in barramundi foraging choices. There were clear zone-dependent differences in Mn, As, Sr and Tl concentrations; levels of Tl were highest in the NCZ, As in the CCZ, and Mn and Sr in the SCZ. Lowest concentrations of Rb occurred in the NCZ, Bi was lowest in the CCZ, and Cd and Cs were lowest in the SCZ. δ 15 N values significantly increased with increasing Zn, Se, Sn and Cs. Concentrations of TEs in barramundi from Vietnam were below worldwide guidelines for human consumption

  17. Concentrations of radionuclides in fish collected from Bikini Atoll between 1977 and 1984

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Jokela, T.A.; Brunk, J.A.

    1986-07-01

    This report summarizes all available data on the concentrations of radionuclides in fish from Bikini Atoll between 1977 and 1984. As found in other global studies, 137 Cs is most highly accumulated in edible flesh of all species of fish, the lowest fractions are found in the bone or liver. The mean concentration of 137 Cs in muscle of reef fish from the southern part of the atoll is comparable to the global fallout concentration measured in market samples of fish collected from Chicago, Illinois, in 1982. 90 Sr is generally associated with non-edible parts of fish, such as bone or viscera. Twenty-five to fifty percent of the total body burden of 60 Co is accumulated in the muscle tissue; the remainder is distributed among the liver, skin, and viscera. The mean concentration of 60 Co in fish has been decreasing at a rate faster than radiological decay alone. Most striking is the range of 207 Bi concentrations among different species of fish collected at the same time and place. Highest concentrations of 207 Bi were consistently detected in the muscle (and other tissues) of goatfish and some of the pelagic lagoon fish. In other reef fish, such as mullet, surgeonfish, and parrotfish, 207 Bi was usually below detection limits by gamma spectrometry. Over 70% of the whole-body activity of 207 Bi in goatfish is associated with the muscle tissue, whereas less than 5% is found in the muscle of mullet and surgeonfish. Neither 239+240 Pu nor 241 Am is significantly accumulated in the muscle tissue of any species of fish. Apparently, 238 Pu is in a more readily available form for accumulation by fishes than 239+240 Pu. Based on a daily ingestion rate of 200 q of fish flesh, dose rates to individuals through the fish-food ingestion pathway are well below current Federal guidelines

  18. On the theoretical analysis of the lowest many-electron states for cyclic zigzag graphene nano-ribbons

    International Nuclear Information System (INIS)

    Álvarez-Collado, José R; Cantarero, Andrés

    2014-01-01

    We have calculated the optical and magnetic properties of the four lowest many-body states for cyclic zigzag graphene nano-ribbons (GNRs). The results have been obtained within the semi-empirical restricted frozen Hartree–Fock approximation. Firstly, we obtained one-determinant numerical and analytical coincident results. We detected the existence of two degenerate open-shell molecular orbitals (MOs) o, o’. Due to this degeneracy, some of the mentioned results do depend on any (arbitrary) orthogonal transformation between these two MOs. We have improved these preliminary results by using linear combinations of two determinants, which are eigenfunctions of the operators, which commute with the electronic Hamiltonian. These eigenfunctions represent properly the wave functions of these four electronic states. These calculations show that there are two degenerate ground states. One of them is ferromagnetic and the other state is non magnetic. Finally, we have calculated these four states to full configuration interaction level studying the dependence of their properties on the size of the GNRs. (paper)

  19. On the theoretical analysis of the lowest many-electron states for cyclic zigzag graphene nano-ribbons

    Science.gov (United States)

    Álvarez-Collado, José R.; Cantarero, Andrés

    2014-09-01

    We have calculated the optical and magnetic properties of the four lowest many-body states for cyclic zigzag graphene nano-ribbons (GNRs). The results have been obtained within the semi-empirical restricted frozen Hartree-Fock approximation. Firstly, we obtained one-determinant numerical and analytical coincident results. We detected the existence of two degenerate open-shell molecular orbitals (MOs) o, o’. Due to this degeneracy, some of the mentioned results do depend on any (arbitrary) orthogonal transformation between these two MOs. We have improved these preliminary results by using linear combinations of two determinants, which are eigenfunctions of the operators, which commute with the electronic Hamiltonian. These eigenfunctions represent properly the wave functions of these four electronic states. These calculations show that there are two degenerate ground states. One of them is ferromagnetic and the other state is non magnetic. Finally, we have calculated these four states to full configuration interaction level studying the dependence of their properties on the size of the GNRs.

  20. Concentration of metals in fishes from Thane and Bassein creeks of Bombay, India

    Digital Repository Service at National Institute of Oceanography (India)

    Krishnamurti, A.J.; Nair, V.R.

    -58% to the total metals accumulated. Maximum concentration of all metals was found either in liver or in alimentary canal with lowest level in muscle tissue. Though metal accumulation was found to be species specific maximum concentrations were found in bottom...

  1. Detection capabilities and accuracy requirements of concentrations of radioactive material in air for radiation protection purposes

    International Nuclear Information System (INIS)

    Brodsky, A.

    1987-01-01

    Recent developments in the formulation of detection capability and accuracy criteria for bioassay measurements will be interpreted and adapted to provide similar criteria for the measurement of air concentrations of radioactive material for radiation protection purposes. Considerations of accuracy will be related to the known variability of measurement processes, as well as the uncertainties in the calculated limits of intake that serve as the basis of regulatory and voluntary standards of practice. Formulations and criteria will be presented for minimum detection amounts (MDA) and precision and bias of measurements for radiation protection purposes. 17 references

  2. Detection of ultra-low oxygen concentration based on the fluorescence blinking dynamics of single molecules

    Science.gov (United States)

    Wu, Ruixiang; Chen, Ruiyun; Zhou, Haitao; Qin, Yaqiang; Zhang, Guofeng; Qin, Chengbing; Gao, Yan; Gao, Yajun; Xiao, Liantuan; Jia, Suotang

    2018-01-01

    We present a sensitive method for detection of ultra-low oxygen concentrations based on the fluorescence blinking dynamics of single molecules. The relationship between the oxygen concentration and the fraction of time spent in the off-state, stemming from the population and depopulation of triplet states and radical cationic states, can be fitted with a two-site quenching model in the Stern-Volmer plot. The oxygen sensitivity is up to 43.42 kPa-1 in the oxygen partial pressure region as low as 0.01-0.25 kPa, which is seven times higher than that of the fluorescence intensity indicator. This method avoids the limitation of the sharp and non-ignorable fluctuations that occur during the measurement of fluorescence intensity, providing potential applications in the field of low oxygen-concentration monitoring in life science and industry.

  3. A q-Schroedinger algebra, its lowest weight representations and generalized q-deformed heat equations

    International Nuclear Information System (INIS)

    Dobrev, V.K.; Doebner, H.D.; Mrugalla, C.

    1995-12-01

    We give a q-deformation S-perpendicular q of the centrally extended Schroedinger algebra. We construct the lowest weight representations of S-perpendicular q , starting from the Verma modules over S-perpendicular q , finding their singular vectors and factoring the Verma submodules built on the singular vectors. We also give a vector-field realization of S-perpendicular q which provides polynomial realization of the lowest weight representations and an infinite hierarchy of q-difference equations which may be called generalized q-deformed heat equations. We also apply our methods to the on-shell q-Schroedinger algebra proposed by Floreanini and Vinet. (author). 12 refs

  4. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    Science.gov (United States)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Electrochemical Detection of Ultratrace (Picomolar) Levels of Hg2+ Using a Silver Nanoparticle-Modified Glassy Carbon Electrode.

    Science.gov (United States)

    Suherman, Alex L; Ngamchuea, Kamonwad; Tanner, Eden E L; Sokolov, Stanislav V; Holter, Jennifer; Young, Neil P; Compton, Richard G

    2017-07-05

    Ultratrace levels of Hg 2+ have been quantified by undertaking linear sweep voltammetry with a silver nanoparticle-modified glassy carbon electrode (AgNP-GCE) in aqueous solutions containing Hg 2+ . This is achieved by monitoring the change in the silver stripping peak with Hg 2+ concentration resulting from the galvanic displacement of silver by mercury: Ag(np) + 1/2Hg 2+ (aq) → Ag + (aq) + 1/2Hg(l). This facile and reproducible detection method exhibits an excellent linear dynamic range of 100.0 pM to 10.0 nM Hg 2+ concentration with R 2 = 0.982. The limit of detection (LoD) based on 3σ is 28 pM Hg 2+ , while the lowest detectable level for quantification purposes is 100.0 pM. This method is appropriate for routine environmental monitoring and drinking water quality assessment since the guideline value set by the US Environmental Protection Agency (EPA) for inorganic mercury in drinking water is 0.002 mg L -1 (10 nM).

  6. Ultra-fast low concentration detection of Candida pathogens utilizing high resolution micropore chips.

    Science.gov (United States)

    Mulero, Rafael; Lee, Dong Heun; Kutzler, Michele A; Jacobson, Jeffrey M; Kim, Min Jun

    2009-01-01

    Although Candida species are the fourth most common cause of nosocomial blood stream infections in the United States, early diagnostic tools for invasive candidemia are lacking. Due to an increasing rate of candidemia, a new screening system is needed to detect the Candida species in a timely manner. Here we describe a novel method of detection using a solid-state micro-scale pore similar to the operational principles of a Coulter counter. With a steady electrolyte current flowing through the pore, measurements are taken of changes in the current corresponding to the shape of individual yeasts as they translocate or travel through the pore. The direct ultra-fast low concentration electrical addressing of C. albicans has established criteria for distinguishing individual yeast based on their structural properties, which may reduce the currently used methods' complexity for both identification and quantification capabilities in mixed blood samples.

  7. Ultra-Fast Low Concentration Detection of Candida Pathogens Utilizing High Resolution Micropore Chips

    Directory of Open Access Journals (Sweden)

    2009-03-01

    Full Text Available Although Candida species are the fourth most common cause of nosocomial blood stream infections in the United States, early diagnostic tools for invasive candidemia are lacking. Due to an increasing rate of candidemia, a new screening system is needed to detect the Candida species in a timely manner. Here we describe a novel method of detection using a solid-state micro-scale pore similar to the operational principles of a Coulter counter. With a steady electrolyte current flowing through the pore, measurements are taken of changes in the current corresponding to the shape of individual yeasts as they translocate or travel through the pore. The direct ultra-fast low concentration electrical addressing of C. albicans has established criteria for distinguishing individual yeast based on their structural properties, which may reduce the currently used methods’ complexity for both identification and quantification capabilities in mixed blood samples

  8. Sensor development for in situ detection of concentration polarization and fouling of reverse osmosis membranes

    Science.gov (United States)

    Detrich, Kahlil T.; Goulbourne, Nakhiah C.

    2009-03-01

    The purpose of this research is to evaluate three polymer electroding techniques in developing a novel in situ sensor for an RO system using the electrical response of a thin film composite sensor. Electrical impedance spectroscopy (EIS) was used to measure the sensor response when exposed to sodium chloride solutions with concentrations from 0.1 M to 0.8 M in both single and double bath configurations. An insulated carbon grease sensor was mechanically stable while a composite Direct Assembly Process (DAP) sensor was fragile upon hydration. Scanning electron microscopy results from an impregnation-reduction technique showed gold nanoparticles were deposited most effectively when presoaked in a potassium hydroxide solution and on an uncoated membrane; surface resistances remained too high for sensor implementation. Through thickness carbon grease sensors showed a transient response to changes in concentration, and no meaningful concentration sensitivity was noted for the time scales over which EIS measurements were taken. Surface carbon grease electrodes attached to the polyamide thin film were not sensitive to concentration. The impedance spectra indicated the carbon grease sensor was unable to detect changes in concentration in double bath experiments when implemented with the polyamide surface exposed to salt solutions. DAP sensors lacked a consistent response to changes in concentration too. A reverse double bath experiment with the polysulfone layer exposed to a constant concentration exhibited a transient impedance response similar to through thickness carbon grease sensors in a single bath at constant concentration. These results suggest that the microporous polysulfone layer is responsible for sensor response to concentration.

  9. Temperature Programmed Desorption of Quench-condensed Krypton and Acetone in Air; Selective Concentration of Ultra-trace Gas Components.

    Science.gov (United States)

    Suzuki, Taku T; Sakaguchi, Isao

    2016-01-01

    Selective concentration of ultra-trace components in air-like gases has an important application in analyzing volatile organic compounds in the gas. In the present study, we examined quench-condensation of the sample gas on a ZnO substrate below 50 K followed by temperature programmed desorption (TPD) (low temperature TPD) as a selective gas concentration technique. We studied two specific gases in the normal air; krypton as an inert gas and acetone as a reactive gas. We evaluated the relationship between the operating condition of low temperature TPD and the lowest detection limit. In the case of krypton, we observed the selective concentration by exposing at 6 K followed by thermal desorption at about 60 K. On the other hand, no selectivity appeared for acetone although trace acetone was successfully concentrated. This is likely due to the solvent effect by a major component in the air, which is suggested to be water. We suggest that pre-condensation to remove the water component may improve the selectivity in the trace acetone analysis by low temperature TPD.

  10. Concentration of circulating miRNA-containing particles in serum enhances miRNA detection and reflects CRC tissue-related deregulations.

    Science.gov (United States)

    ElSharawy, Abdou; Röder, Christian; Becker, Thomas; Habermann, Jens K; Schreiber, Stefan; Rosenstiel, Philip; Kalthoff, Holger

    2016-11-15

    The emerging potential of miRNAs as biomarkers for cancer detection demands parallel evaluation of strategies for reliable identification of disease-related signatures from easily accessible and pertinent body compartments. Here, we addressed whether efficient concentration of circulating miRNA-carrying particles is a rationale for miRNA biomarker discovery. We systematically compared miRNA signatures in 93 RNA preparations from three serum entities (whole serum, particle-concentrated, and particle-depleted fractions) and corresponding tissue samples from patients with colorectal cancer (CRC) as a model disease. Significant differences between whole sera and particle-concentrated serum fractions of CRC patients emerged for 45 of 742 tested miRNAs. Twenty-eight of these 45 miRNAs were differentially expressed between particle-concentrated serum fractions of metastatic CRC- and healthy individuals. Over half of these candidates (15 of 28) showed deregulations only in concentrated serum fractions, but not in whole sera, compared to the respective controls.Our results also provided evidence of a consistent downregulation of miR-486 and miR-92a, and further showed a possible "strand-specific" deregulation of extracellular miRNAs in CRC. More importantly, most of the identified miRNAs in the enriched sera reflected the patterns of the corresponding tumor tissues and showed links to cancer-related inflammation. Further investigation of seven serum pools revealed a subset of potential extracellular miRNA candidates to be implicated in both neoplastic and inflammatory bowel disease.Our findings demonstrate that enrichment and sensitive detection of miRNA carriers is a promising approach to detect CRC-related pathological changes in liquid biopsies, and has potential for clinical diagnostics.

  11. Using hyper-spectral indices to detect soil phosphorus concentration for various land use patterns.

    Science.gov (United States)

    Lin, Chen; Ma, Ronghua; Zhu, Qing; Li, Jingtao

    2015-01-01

    The management of nonpoint source pollution requires accurate information regarding soil phosphorus concentrations for different land use patterns. The use of remotely sensed information provides an important opportunity for such studies, and the previous studies showed that soil phosphorus shows no clear spectral response feature, while the phosphorus concentrations can be indirectly detected from the normalised difference vegetation indices (NDVI). Therefore, this study uses an optimised index in the RED and near-infrared (NIR) wavelengths to estimate total phosphorus and Olsen-P concentrations. The prediction accuracy is not entirely satisfactory with respect to a mixed land use dataset in which the determination coefficient was maintained at approximately 0.6, with particularly poor performance obtained for forest land group. However, the prediction accuracy increases markedly with the separation of samples into broad land use categories, even the R(2) was exceeded 0.8 for tea plantation group. The soil phosphorus prediction effect showed obvious variance for different land use patterns, which was related to vegetation growth conditions and critical soil properties including soil organic matter and mechanical composition.

  12. Spatial variation of epoxyscillirosidine concentrations in Moraea pallida (yellow tulp in South Africa

    Directory of Open Access Journals (Sweden)

    Christo J. Botha

    2013-05-01

    Full Text Available Moraea pallida (yellow tulp poisoning is economically the most important intoxication of livestock in South Africa. Poisoning varies according to locality, climatic conditions and growth stage of the plant. The primary objective of this study was to determine the concentration of the toxic principle, epoxyscillirosidine, in yellow tulp leaves and to ascertain the variability of epoxyscillirosidine concentrations within and between different locations. A secondary objective was to utilise Geographic Information Systems in an attempt to explain the variability in toxicity. Flowering yellow tulp plants were collected at 26 sampling points across 20 districts of South Africa. The leaves of five plants per sampling point were extracted and submitted for liquid chromatography/mass spectrometry analysis. A large variation in mean epoxyscillirosidine concentrations, ranging from 3.32 μg/g – 238.27 μg/g, occurred between different geographical regions. The epoxyscillirosidine concentrations also varied tremendously between individual plants (n= 5 collected at the same sampling point, with up to a 24 times difference between the lowest and highest concentration detected. No generalised correlation between epoxyscillirosidine concentrations and soil elemental concentrations could be established. However, samples obtained from the north-eastern part of the sampling region tended to have higher epoxyscillirosidine concentrations compared to samples obtained from the south-western part of the sampling region. Higher toxin concentrations in the northeast were associated with statistically significant higher soil concentrations of iron, bismuth, bromide, cadmium, chromium, rubidium, tellurium, thallium, titanium and zinc, whilst soil concentrations of strontium and soil pH, were significantly lower. This study corroborated the contention that epoxyscillirosidine concentration in yellow tulp fluctuates and may explain the variability in toxicity.

  13. Concept for lowest emissions of a hydrogen internal combustion engine; Niedrigstemissionskonzept fuer einen wasserstoffbetriebenen Verbrennungsmotor

    Energy Technology Data Exchange (ETDEWEB)

    Fouquet, Marcel Christian Thomas

    2012-03-15

    This paper describes a concept with lowest emissions for a hydrogen internal combustion engine for passenger cars. With optimisation of the combustion concept the level of nitrogen oxide is below 90%, hydrocarbon and carbon monoxide below 99% of the SULEV target (CARB). This concept enables a potential in power density that is comparable to current supercharged combustion engines at lowest emission level without catalytic aftertreatment. Additionally with a catalytic aftertreatment system, the emission level of a current hydrogen combustion engine (mono-fuel) is lowered to a level, that this car can be labeled as air cleaning vehicle for hydrocarbons and carbon monoxide.

  14. A comparison of methods for monitoring low airborne concentrations of argon-41 and tritium, with MIT-PFC design applications

    International Nuclear Information System (INIS)

    McLoughlin, J.C.

    1990-08-01

    Two primary methods, GM- and NaI-detection, of airborne 41 Ar monitoring were compared experimentally to determine the lowest resolvable concentration given reasonable sample sizes. NaI-detectors provided a lower resolvable concentration than GM tubes, primarily due to energy resolution, which greatly reduced background noise. Airborne 3 H collection was compared for two primary collection and one ancillary method (direct condensation). All 3 H detection was performed via liquid scintillation. Tritium collection with water baths yielded higher collection efficiencies than dessicant traps for short sampling durations. As the length of the sampling duration increased, water traps yielded lower collection efficiencies than dessicant traps, primarily due to evaporation of water from the water traps. Direct condensation as a collection method of airborne 3 H was found unsuitable, since large amounts of gas were initially condensed, yet evaporated as the sample's coolant was removed. 41 Ar detection for the MIT-PFC was determined to be best provided by a low 40 K NaI crystal shielded with lead and steel. A Marinelli beaker was used as a monitoring volume to hold the effluent sample. 3 H monitoring at the MIT-PFC was fulfilled with dessicant traps to catalytically separate the [HTO] and [HT] fractions without the use of a carrier gas for the [HT

  15. Aqueous vascular endothelial growth factor and aflibercept concentrations after bimonthly intravitreal injections of aflibercept for age-related macular degeneration.

    Science.gov (United States)

    Sawada, Tomoko; Wang, Xiying; Sawada, Osamu; Saishin, Yoshitsugu; Ohji, Masahito

    2018-01-01

    Clinical evidence supports the efficacy of bimonthly aflibercept injection for age-related macular degeneration. The study aimed to evaluate aqueous vascular endothelial growth factor and aflibercept concentrations and the efficacy of bimonthly aflibercept in patients with age-related macular degeneration. This study is a prospective, interventional case series. Enrolled were 35 eyes with exudative age-related macular degeneration from 35 patients. Patients received three bimonthly intravitreal aflibercept without loading doses. We collected the aqueous humor just before each injection, measured vascular endothelial growth factor and aflibercept concentrations by enzyme-linked immunosorbent assay and measured best-corrected visual acuity and central retinal subfield thickness before and after the injections. Aqueous vascular endothelial growth factor and aflibercept concentrations were measured. The vascular endothelial growth factor concentration was 135.4 ± 60.5 pg/mL (mean ± standard deviation, range 60.6-323.4) at baseline and below the lowest detectable limit in all eyes at month 2 and in 32 eyes at month 4 (P age-related macular degeneration. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  16. Agglomerative concentric hypersphere clustering applied to structural damage detection

    Science.gov (United States)

    Silva, Moisés; Santos, Adam; Santos, Reginaldo; Figueiredo, Eloi; Sales, Claudomiro; Costa, João C. W. A.

    2017-08-01

    The present paper proposes a novel cluster-based method, named as agglomerative concentric hypersphere (ACH), to detect structural damage in engineering structures. Continuous structural monitoring systems often require unsupervised approaches to automatically infer the health condition of a structure. However, when a structure is under linear and nonlinear effects caused by environmental and operational variability, data normalization procedures are also required to overcome these effects. The proposed approach aims, through a straightforward clustering procedure, to discover automatically the optimal number of clusters, representing the main state conditions of a structural system. Three initialization procedures are introduced to evaluate the impact of deterministic and stochastic initializations on the performance of this approach. The ACH is compared to state-of-the-art approaches, based on Gaussian mixture models and Mahalanobis squared distance, on standard data sets from a post-tensioned bridge located in Switzerland: the Z-24 Bridge. The proposed approach demonstrates more efficiency in modeling the normal condition of the structure and its corresponding main clusters. Furthermore, it reveals a better classification performance than the alternative ones in terms of false-positive and false-negative indications of damage, demonstrating a promising applicability in real-world structural health monitoring scenarios.

  17. Detecting microalbuminuria by urinary albumin/creatinine concentration ratio

    DEFF Research Database (Denmark)

    Jensen, J S; Clausen, P; Borch-Johnsen, K

    1997-01-01

    BACKGROUND: Microalbuminuria, i.e. a subclinical increase of the albumin excretion rate in urine, may be a novel atherosclerotic risk factor. This study aimed to test whether microalbuminuria can be identified by measurement of urinary albumin concentration or urinary albumin/creatinine concentra......BACKGROUND: Microalbuminuria, i.e. a subclinical increase of the albumin excretion rate in urine, may be a novel atherosclerotic risk factor. This study aimed to test whether microalbuminuria can be identified by measurement of urinary albumin concentration or urinary albumin/creatinine...... not included. Urinary albumin (Ualb) and creatinine (Ucreat) concentrations were measured in an overnight collected sample by enzyme-linked immunosorbent and colorimetric assays, respectively. Urinary albumin excretion rate (UAER) and urinary albumin/creatinine concentration ratio (Ualb/Ucreat) were calculated......, and 73%, 97%, and 73% for Ualb/Ucreat, respectively. CONCLUSIONS: It is concluded that measurement of the albumin/creatinine concentration ratio is a specific and quite sensitive alternative to measurement of the urinary albumin excretion rate in timed collections, when screening for microalbuminuria....

  18. Detection of land mines by amplified fluorescence quenching of polymer films: a man-portable chemical sniffer for detection of ultratrace concentrations of explosives emanating from land mines

    Science.gov (United States)

    la Grone, Marcus J.; Cumming, Colin J.; Fisher, Mark E.; Fox, Michael J.; Jacob, Sheena; Reust, Dennis; Rockley, Mark G.; Towers, Eric

    2000-08-01

    The explosive charge within a landmine is the source for a mixture of chemical vapors that form a distinctive 'chemical signature' indicative of a landmine. The concentration of these compounds in the air over landmines is extremely low, well below the minimum detection limits of most field- portable chemical sensors. Described in this paper is a man- portable landmine detection system that has for the first time demonstrated the ability to detect landmines by direct sensing of the vapors of signature compounds in the air over landmines. The system utilizes fluorescent polymers developed by collaborators at the MIT. The sensor can detect ultra-trace concentrations of TNT vapor and other nitroaromatic compounds found in many landmine explosives. Thin films of the polymers exhibit intense fluorescence, but when exposed to vapors of nitroaromatic explosives the intensity of the light emitted from the films decreases. A single molecule of TNT binding to a receptor site quenches the fluorescence from many polymer repeat units, increasing the sensitivity by orders of magnitude. A sensor prototype has been develop that response in near real-time to low femtogram quantities of nitroaromatic explosives. The prototype is portable, lightweight, has low power consumption, is simple to operate, and is relatively inexpensive. Simultaneous field testing of the sensor and experienced canine landmine detection teams was recently completed. Although the testing was limited in scope, the performance of the senor met or exceeded that of the canines against buried landmines.

  19. Hydrolysis with Cucurbita ficifolia serine protease reduces antigenic response to bovine whey protein concentrate and αs-casein.

    Science.gov (United States)

    Babij, Konrad; Bajzert, Joanna; Dąbrowska, Anna; Szołtysik, Marek; Zambrowicz, Aleksandra; Lubec, Gert; Stefaniak, Tadeusz; Willak-Janc, Ewa; Chrzanowska, Józefa

    2015-11-01

    In the present study the effect of hydrolysis with non-commercial Cucurbita ficifolia serine protease on a reduction of the IgE and IgG binding capacity of whey protein concentrate and αs-casein was investigated. The intensity of the protein degradation was analyzed by the degree of hydrolysis, the free amino groups content and RP-HPLC. The ability to bind the antibodies by native proteins and their hydrolysates was determined using a competitive ELISA test. Deep hydrolysis contributed to a significant reduction of immunoreactive epitopes present in WPC. In the case of IgE and IgG present in the serum pool of children with CMA, the lowest binding capacity was detected in the 24 h WPC hydrolysate, where the inhibition of the reaction with native WPC was ≤23 and ≤60 %, respectively. The analysis of the IgG reactivity in the antiserum of the immunized goat showed that the lowest antibody binding capacity was exhibited also by 24 h WPC hydrolysate at a concentration of 1000 μg/ml where the inhibition of the reaction with nWPC was ≤47 %. One-hour hydrolysis of α-casein was sufficient to significant reduction of the protein antigenicity, while the longer time (5 h) of hydrolysis probably lead to the appearance of new epitopes reactive with polyclonal.

  20. [Detection of rifampicin concentration in cerebrospinal fluid by online enrichment and restricted-access media coupled with high-performance liquid chromatography].

    Science.gov (United States)

    Yang, Xiaoping; Zhang, Xiaohui; Huang, Yanping; Wang, Rong; Xia, Hua; Li, Wenbin; Guo, YouMin

    2015-11-01

    To establish a method for detecting rifampicin in human cerebrospinal fluid (CSF) with restricted access media coupled with high-performance liquid chromatography that allows online direct sample injection and enrichment. We used the column of restricted access media as the pre-treatment column and a C18 column as the analytical column. The mobile phase of pre-treatment column was water-methanol (95:5,V/V) and the flow rate was 1 mL/min; the mobile phase of the analytical column was methanol-acetonitrile-10 mmol/L ammonuium acetate (volume ratio of 60:5:35). The detection wavelength was 254 nm and the column temperature was set at 25 degrees celsius;. For an injection volume of 100 µL, the peak area of rifampicin was 5.33 times that for an injection volume of 20 µL, and the limit of detection was effectively improved. The calibration curve showed an excellent linear relationship (r=0.9997) between rifampicin concentrations and peak areas within the concentration range of 0.25 to 8 µg/mL in CSF. The limits of detection and quantification was 0.07 µg/mL and 0.25 µg/mL, respecetively, with intra-day and inter-day assay precisions and relative standard deviation (RSD%) all below 5%. The recoveries of rifampicin at 3 blank spiked levels (low, medium, and high) ranged from 87.69% to 102.11%. In patients taking oral rifampicin at the dose of 10 mg/kg, the average rifampicin concentration was 0.29 in the CSF at 2 h after medication. The method we established is simple and fast for detecting rifampicin in CSF and allows direct online injection and enrichment with good detection precisions and accuracies.

  1. Ultra-wide detectable concentration range of GMR biosensors using Fe{sub 3}O{sub 4} microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jie [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); School of Chemical Science and Engineering, Qingdao University, Qingdao 266071 (China); Li, Qiang [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); Zong, Weihua [Shandong Provincial Key Laboratory of Industrial Control Technology, Qingdao University, Qingdao 266071 (China); Zhang, Yongcheng [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); Li, Shandong, E-mail: lishd@qdu.edu.cn [College of Physics, Key Laboratory of Photonics Materials and Technology in Universities of Shandong, and Laboratory of Fiber Materials and Modern Textile, the Growing Base for State Key Laboratory, Qingdao University, Qingdao 266071 (China); National Laboratory of Solid State Microstructures, Nanjing University, Nanjing 210093 (China)

    2016-11-01

    Exchange-biased GMR sensors were employed for biodetection using a DC in-plane measuring method and a magnetic label of Fe{sub 3}O{sub 4} microspheres. It was revealed that an ultra-wide concentration span covering five orders from 10 ng/mL to 1000 μg/mL was achieved in a home-made biodetection device. The concentration x dependence of output voltage difference |ΔV| between with and without magnetic labels, exhibits nonlinear futures, which undergoes two functions depending on the concentration region. For the low concentration region from 10 ng/mL to 10 μg/mL, a logarithmic relation of |ΔV|=26.3lgx+91.4 fits well, while for the high concentration region, a negative exponential function of |ΔV|=3113(1−e{sup −x/250}) describes the |ΔV|~x relation better. For the former, the “coffee ring” effect, formed during the solvent evaporation, was considered as the main reason for the nonlinear relation. While for the latter with high concentration, the overlap among the particles and the enhanced interaction of the magnetic dipole were responsible for the nonlinear |ΔV|~x relationship. Moreover, the calculated detectable concentration limit is agreed well with the experimental data. - Highlights: • Ultra-wide concentration span covering five orders from 0.01 to 1000 μg/mL. • A logarithmic function well describes the relation of |ΔV|~x at low concentration. • An exponential function well describes the relation of |ΔV|~x at high concentration.

  2. A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations.

    Science.gov (United States)

    Ma, Wei-Jhe; Luo, Ching-Hsing; Lin, Jiun-Ling; Chou, Sin-Houng; Chen, Ping-Hung; Syu, Mei-Jywan; Kuo, Shin-Hung; Lai, Shin-Chi

    2016-04-02

    This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10(-4) to 3.16 × 10(-2) M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R² = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications.

  3. Polymethylmethacrylate-based luminescent solar concentrators with bottom-mounted solar cells

    International Nuclear Information System (INIS)

    Zhang, Yi; Sun, Song; Kang, Rui; Zhang, Jun; Zhang, Ningning; Yan, Wenhao; Xie, Wei; Ding, Jianjun; Bao, Jun; Gao, Chen

    2015-01-01

    Graphical abstract: - Highlights: • Bottom-mounted luminescent solar concentrators on dye-doped plates were studied. • The mechanism of transport process was proposed. • The fabricated luminescent solar concentrator achieved a gain of 1.38. • Power conversion efficiency of 5.03% was obtained with cell area coverage of 27%. • The lowest cost per watt of $1.89 was optimized with cell area coverage of 18%. - Abstract: Luminescent solar concentrators offer an attractive approach to concentrate sunlight economically without tracking, but the narrow absorption band of luminescent materials hinders their further development. This paper describes bottom-mounted luminescent solar concentrators on dye-doped polymethylmethacrylate plates that absorb not only the waveguided light but also the transmitted sunlight and partial fluorescent light in the escape cone. A series of bottom-mounted luminescent solar concentrators with size of 78 mm × 78 mm × 7 mm were fabricated and their gain and power conversion efficiency were investigated. The transport process of the waveguided light and the relationship between the bottom-mounted cells were studied to optimize the performance of the device. The bottom-mounted luminescent solar concentrator with cell area coverage of 9% displayed a cell gain of 1.38, to our best knowledge, which is the highest value for dye-doped polymethylmethacrylate plate luminescent solar concentrators. Power conversion efficiency as high as 5.03% was obtained with cell area coverage of 27%. Furthermore, the bottom-mounted luminescent solar concentrator was found to have a lowest cost per watt of $1.89 with cell area coverage of 18%. These results suggested that the fabricated bottom-mounted luminescent solar concentrator may have a potential in low-cost building integrated photovoltaic application

  4. Lowest instrumented vertebra selection in Lenke 3C and 6C scoliosis

    DEFF Research Database (Denmark)

    Wang, Yu; Bünger, Cody; Zhang, Yanqun

    2012-01-01

    PURPOSE: The aim of this study was to investigate whether or not post-op curve behaviour differs due to different choices of lowest instrumented vertebra (LIV) with reference to lumbar apical vertebra (LAV) in Lenke 3C and 6C scoliosis. METHODS: We reviewed all the AIS cases surgically treated...... it can yield similar correction while preserving more lumbar mobility and growth potential....

  5. Aromatic hydrocarbon concentrations in sediments of Placentia Bay, Newfoundland

    International Nuclear Information System (INIS)

    Kiceniuk, J.W.

    1992-01-01

    A study was conducted to examine the potential for contamination of recent sediments with polycyclic aromatic hydrocarbons due to tanker and refinery activity in Placentia Bay, Newfoundland, an area without large local anthropogenic sources of aromatics. Sediment samples were taken from the vicinity of the Come By Chance refinery, Woody Island, Wild Cove, and Port Royal Arm, all in the north end of the bay. The samples were extracted by two methods, dichloromethane extraction of dried sediment for determination of total aromatic hydrocarbon content and hexane extraction of wet sediment for estimation of the bioavailability of hydrocarbons and determination of more volatile compounds. Class analysis of aromatic hydrocarbons was conducted on a NH 2 column with detection at 255 nm. Total concentrations of di-tricyclic aromatics were highest at the Woody Island site (0.6 μg/g). The sediments from the Come By Chance site, Wild Cove, and Port Royal Arm sediments contained 0.3, 0.1, and 0.2 μg/g respectively. The hexane extracts from Come By Chance were lowest in di-tricyclic aromatics (0.007 μg/g), with the other sites being equal in concentration (0.01 μg/g). It is evident from the study that aromatic hydrocarbon concentrations in Placentia Bay are elevated in some parts of the bay in the absence of local combustion sources, and that the most likely source is petroleum. 12 refs., 5 figs., 2 tabs

  6. The detection of pesticides in water using ZnCdSe quantum dot films

    International Nuclear Information System (INIS)

    Bakar, N A; Salleh, M M; Umar, A A; Yahaya, M

    2011-01-01

    This paper reports an attempt to develop a sensor system for detecting pesticides based on the effect of an analyte on the photoluminescence (PL) intensity of ZnCdSe quantum dot (QD) films. The ZnCdSe QDs were synthesized using a wet-chemical process. The sensor system comprises an excitation light source made of a laser diode, a dual arm fibre optic probe, a spectrometer and a sensor chamber. The QD films were deposited by dropping QD solution onto the probe surface and drying them at ambient temperature. The pesticides used in this study were Dipel, Siven 85% WP and Water-Dispersible Granules WG insecticides. The detection of pesticides was done by comparing the photoluminescence (PL) spectra of the films dipped in the deionized water and in pesticide solutions by varying the concentration of the pesticide solutions from 2.5 to 2500 μg l −1 . It was observed that the PL intensity of the films was quenched by the presence of the pesticide molecules. The quenching degree increased with the concentration of the pesticide solutions. There is a linear relationship between the pesticide solution concentrations and the QD film sensor sensitivities. The sensitivity of the sensor system depended on the type of pesticides successively from the highest to lowest sensitivity in the order Siven 85% WP, Dipel and Water-Dispersible Granules WG. The QD films could be used as fluorescence sensors to detect water that is contaminated by pesticides

  7. People In Sub-Saharan Africa Rate Their Health And Health Care Among Lowest In World

    Science.gov (United States)

    Deaton, Angus S.; Tortora, Robert

    2017-01-01

    The health of people in sub-Saharan Africa is a major global concern. However, data are weak, and little is known about how people in the region perceive their health or their health care. We used data from the Gallup World Poll in 2012 to document sub-Saharan Africans’ perceived health status, their satisfaction with health care, their contact with medical professionals, and the priority they attach to health care. In comparison to other regions of the world, sub-Saharan Africa has the lowest ratings for well-being and the lowest satisfaction with health care. It also has the second lowest perception of personal health, after only the former Soviet Union and its satellites. HIV prevalence is positively correlated with perceived improvements in health care in countries with high prevalence. This is consistent with an improvement in at least some health care services as a result of the largely aid-funded rollout of antiretroviral treatment. Even so, sub-Saharan Africans do not prioritize health care as a matter of policy, although donors are increasingly shifting their aid efforts in sub-Saharan Africa toward health. PMID:25715657

  8. Sensor integration of multiple tripolar concentric ring electrodes improves pentylenetetrazole-induced seizure onset detection in rats.

    Science.gov (United States)

    Makeyev, Oleksandr; Ding, Quan; Kay, Steven M; Besio, Walter G

    2012-01-01

    As epilepsy affects approximately one percent of the world population, electrical stimulation of the brain has recently shown potential for additive seizure control therapy. Previously, we applied noninvasive transcranial focal stimulation via tripolar concentric ring electrodes on the scalp of rats after inducing seizures with pentylenetetrazole. We developed a system to detect seizures and automatically trigger the stimulation and evaluated the system on the electrographic activity from rats. In this preliminary study we propose and validate a novel seizure onset detection algorithm based on exponentially embedded family. Unlike the previously proposed approach it integrates the data from multiple electrodes allowing an improvement of the detector performance.

  9. Electrochemical detection of dopamine using arrays of liquid-liquid micro-interfaces created within micromachined silicon membranes

    International Nuclear Information System (INIS)

    Berduque, Alfonso; Zazpe, Raul; Arrigan, Damien W.M.

    2008-01-01

    The detection of protonated dopamine by differential pulse voltammetry (DPV) and square wave voltammetry (SWV) at arrays of micro-interfaces between two immiscible electrolyte solutions (μITIES) is presented. Microfabricated porous silicon membranes (consisting of eight pores, 26.6 μm in radius and 500 μm pore-pore separation, in a hexagonal layout) were prepared by photolithographic and etching procedures. The membrane pores were fabricated with hydrophobic internal walls so that the organic phase filled the pores and created the liquid interface at the aqueous side of the membrane. These were used for harnessing the benefits of three-dimensional diffusion to the interface and for interface stabilisation. The liquid-liquid interface provides a simple method to overcome the major problem in the voltammetric detection of dopamine at solid electrodes due to the co-existence of ascorbate at higher concentrations. Selectivity for dopamine over ascorbate was achieved by the use of dibenzo-18-crown-6 (DB18C6) for the facilitated ion transfer of dopamine across the μITIES array. Under these conditions, the presence of ascorbate in excess did not interfere in the detection of dopamine and the lowest concentration detectable was ca. 0.5 μM. In addition, the drawback of current signal saturation (non-linear increase of the peak current with the concentration of dopamine) observed at conventional (millimetre-sized) liquid-liquid interfaces was overcome using the microfabricated porous membranes

  10. Estimating concentration of fluoride in edible leaves locally grown around Raipur, Chhattisgarh

    Directory of Open Access Journals (Sweden)

    Anubhuti Jain

    2017-01-01

    Full Text Available Introduction: Fluorine is the 13th most abundant element in the earth crust and is available in various environmental, clinical, and food samples in varied concentrations. Aim: To estimate concentration of fluoride in five medicinal and five nonmedicinal edible leaves locally grown around Raipur, Chhattisgarh, India. Materials and Methods: Samples of ten medicinal and nonmedicinal edible leaves, namely, spinach (Spinacia oleracea, coriander leaves (Coriandrum sativum, chawli bhaji (Amaranthus spinach, lal bhaji (Alternanthera bettzickiana, mooli bhaji (Raphanus sativus, neem (Azadirachta indica, tulsi (Ocimum tenuiflorum, mint leaves (Mentha longifolia, betel leaves (Piper betle, and bael leaves (Aegle marmelos were collected in the clean polyethene bags. After thorough washing with water, leaves were left to dry in ambient temperature and crushed into powder using a mixer grinder. One gram of each of the powdered samples was taken and analyzed for fluoride concentration using a 2-(4-sulfophenylazo 1,8-dihydroxy-3,6-naphthalenedisulfonic acid trisodium salt spectrophotometric method. Results: The presence of fluoride in varied concentrations in locally grown edible leaves were analyzed. The highest concentration of fluoride was reported in tulsi (6.0 μg/g and lowest in mint leaves (1.1 μg/g. Two edible leaves, neem and bael, showed fluoride concentration below detection limit. Conclusion: Knowledge regarding the importance of edible leaves may be lost in the near future unless efforts are made to educate younger generations about their importance. Hence, the time has come to make good use of centuries-old knowledge through modern approaches for their better economic and therapeutic utilization.

  11. Sequence variation does not confound the measurement of plasma PfHRP2 concentration in African children presenting with severe malaria

    Directory of Open Access Journals (Sweden)

    Ramutton Thiranut

    2012-08-01

    Full Text Available Abstract Background Plasmodium falciparum histidine-rich protein PFHRP2 measurement is used widely for diagnosis, and more recently for severity assessment in falciparum malaria. The Pfhrp2 gene is highly polymorphic, with deletion of the entire gene reported in both laboratory and field isolates. These issues potentially confound the interpretation of PFHRP2 measurements. Methods Studies designed to detect deletion of Pfhrp2 and its paralog Pfhrp3 were undertaken with samples from patients in seven countries contributing to the largest hospital-based severe malaria trial (AQUAMAT. The quantitative relationship between sequence polymorphism and PFHRP2 plasma concentration was examined in samples from selected sites in Mozambique and Tanzania. Results There was no evidence for deletion of either Pfhrp2 or Pfhrp3 in the 77 samples with lowest PFHRP2 plasma concentrations across the seven countries. Pfhrp2 sequence diversity was very high with no haplotypes shared among 66 samples sequenced. There was no correlation between Pfhrp2 sequence length or repeat type and PFHRP2 plasma concentration. Conclusions These findings indicate that sequence polymorphism is not a significant cause of variation in PFHRP2 concentration in plasma samples from African children. This justifies the further development of plasma PFHRP2 concentration as a method for assessing African children who may have severe falciparum malaria. The data also add to the existing evidence base supporting the use of rapid diagnostic tests based on PFHRP2 detection.

  12. Effect of pH, ethanol concentration, and temperature on detection of quagga mussel (Dreissena bugensis birefringence

    Directory of Open Access Journals (Sweden)

    Scott O’Meara

    2013-05-01

    Full Text Available In the western United States, federal, state, and local agencies have engaged in extensive efforts to detect the presence of larval dreissenid mussels (veligers in water bodies before such a presence becomes a full-scale infestation. Cross-polarized light microscopy (CPLM is commonly used to detect the veliger’s specific birefringence pattern, but the effect of sample preservation on dreissenid birefringence has not yet been determined. This study examined the effects of solution pH, ethanol concentration, and storage temperature on veliger birefringence loss. Birefringence loss was determined by examining veligers under CPLM at regular intervals over a 30 day period. Veliger birefringence loss was below five percent in all basic solutions, regardless of holding temperature or ethanol concentration. Veliger birefringence loss was also below five percent in acidic solutions that were refrigerated or contained 50–70 percent ethanol. Veligers in acidic solutions that were held at 25°C and 34°C with 0–25 percent ethanol had 7–25 percent veliger birefringence loss over a 30 day period. While ethanol addition and refrigeration are both important preservation methods, the results of this study indicate that samples collected for dreissenid veliger detection by CPLM must also be maintained at a basic pH in order to preserve veliger shell integrity and birefringence. Determining the best conditions for long-term preservation of veliger shells requires further investigation, and these results should not be assumed best for analyses other than CPLM.

  13. Achievable Strength-Based Signal Detection in Quantity-Constrained PAM OOK Concentration-Encoded Molecular Communication.

    Science.gov (United States)

    Mahfuz, Mohammad Upal

    2016-10-01

    In this paper, the expressions of achievable strength-based detection probabilities of concentration-encoded molecular communication (CEMC) system have been derived based on finite pulsewidth (FP) pulse-amplitude modulated (PAM) on-off keying (OOK) modulation scheme and strength threshold. An FP-PAM system is characterized by its duty cycle α that indicates the fraction of the entire symbol duration the transmitter remains on and transmits the signal. Results show that the detection performance of an FP-PAM OOK CEMC system significantly depends on the statistical distribution parameters of diffusion-based propagation noise and intersymbol interference (ISI). Analytical detection performance of an FP-PAM OOK CEMC system under ISI scenario has been explained and compared based on receiver operating characteristics (ROC) for impulse (i.e., spike)-modulated (IM) and FP-PAM CEMC schemes. It is shown that the effects of diffusion noise and ISI on ROC can be explained separately based on their communication range-dependent statistics. With full duty cycle, an FP-PAM scheme provides significantly worse performance than an IM scheme. The paper also analyzes the performance of the system when duty cycle, transmission data rate, and quantity of molecules vary.

  14. Potassium concentration in bone of Beijing residents

    International Nuclear Information System (INIS)

    Lin Lianqing

    1994-01-01

    The author presents the measuring results of K concentration in bone ash samples of 65 residents in Beijing area by atomic absorption spectrum. The results indicate that the K concentrations in bone ash is logarithmic normal distribution, ranging level is 0.75-8.44 g/kg ash, the average and standard deviation is respectively 2.40 and 1.52 g/kg ash. The highest concentration (4.88 g/kg ash) appears in infantile stage (< 1y), the lowest concentration (1.59 g/kg ash) appears in young stage (2-5 y). The lower concentration (1.88 g/kg ash) appears in adolescence (11-20 y). The K concentration in wet bone as a percentage of weight is 0.067%. The specific activities of K-40 in bone is about 22 mBq/g wet bone. The total radioactivity of K-40 in whole bone is 220 Bq. The annual absorbed dose is received in adult bone from K-40 is estimated to be 95 μGy

  15. Using an aqueous two-phase polymer-salt system to rapidly concentrate viruses for improving the detection limit of the lateral-flow immunoassay.

    Science.gov (United States)

    Jue, Erik; Yamanishi, Cameron D; Chiu, Ricky Y T; Wu, Benjamin M; Kamei, Daniel T

    2014-12-01

    The development of point-of-need (PON) diagnostics for viruses has the potential to prevent pandemics and protects against biological warfare threats. Here we discuss the approach of using aqueous two-phase systems (ATPSs) to concentrate biomolecules prior to the lateral-flow immunoassay (LFA) for improved viral detection. In this paper, we developed a rapid PON detection assay as an extension to our previous proof-of-concept studies which used a micellar ATPS. We present our investigation of a more rapid polymer-salt ATPS that can drastically improve the assay time, and show that the phase containing the concentrated biomolecule can be extracted prior to macroscopic phase separation equilibrium without affecting the measured biomolecule concentration in that phase. We could therefore significantly decrease the time of the diagnostic assay with an early extraction time of just 30 min. Using this rapid ATPS, the model virus bacteriophage M13 was concentrated between approximately 2 and 10-fold by altering the volume ratio between the two phases. As the extracted virus-rich phase contained a high salt concentration which destabilized the colloidal gold indicator used in LFA, we decorated the gold nanoprobes with polyethylene glycol (PEG) to provide steric stabilization, and used these nanoprobes to demonstrate a 10-fold improvement in the LFA detection limit. Lastly, a MATLAB script was used to quantify the LFA results with and without the pre-concentration step. This approach of combining a rapid ATPS with LFA has great potential for PON applications, especially as greater concentration-fold improvements can be achieved by further varying the volume ratio. Biotechnol. Bioeng. 2014;111: 2499-2507. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  16. Award of Construction Contracts: Public Institutions' Authority to Select the Lowest Responsible Bidder.

    Science.gov (United States)

    Cole, Elsa Kircher; Goldblatt, Steven M.

    1989-01-01

    The article describes the responsibilities of public colleges and universities to award construction contracts to the lowest responsible bidder; discusses the purpose of bid statutes; and lists the factors institutions should consider in determining a bidder's responsibility. Also covered are the standard of review and due process rights of the…

  17. Electrochemical detection of uric acid using ruthenium-dioxide-coated carbon nanotube directly grown onto Si wafer

    Science.gov (United States)

    Shih, Yi-Ting; Lee, Kuei-Yi; Lin, Chung-Kuang

    2015-12-01

    Carbon nanotubes (CNTs) directly grown onto a Si substrate by thermal chemical vapor deposition were used in uric acid (UA) detection. The process is simple and formation is easy without the need for additional chemical treatments. However, CNTs lack selectivity and sensitivity to UA. To enhance the electrochemical analysis, ruthenium oxide was used as a catalytic mediator in the modification of electrodes. The electrochemical results show that RuO2 nanostructures coated onto CNTs can strengthen the UA signal. The peak currents of RuO2 nanostructures coated onto CNTs linearly increase with increasing UA concentration, meaning that they can work as electrodes for UA detection. The lowest detection limit and highest sensitivity were 55 nM and 4.36 µA/µM, respectively. Moreover, the characteristics of RuO2 nanostructures coated onto CNTs were examined by scanning electron microscopy, transmission electron microscopy, and Raman spectroscopy.

  18. Both RIG-I and MDA5 detect alphavirus replication in concentration-dependent mode

    Energy Technology Data Exchange (ETDEWEB)

    Akhrymuk, Ivan; Frolov, Ilya; Frolova, Elena I., E-mail: evfrolova@UAB.edu

    2016-01-15

    Alphaviruses are a family of positive-strand RNA viruses that circulate on all continents between mosquito vectors and vertebrate hosts. Despite a significant public health threat, their biology is not sufficiently investigated, and the mechanisms of alphavirus replication and virus–host interaction are insufficiently understood. In this study, we have applied a variety of experimental systems to further understand the mechanism by which infected cells detect replicating alphaviruses. Our new data strongly suggest that activation of the antiviral response by alphavirus-infected cells is determined by the integrity of viral genes encoding proteins with nuclear functions, and by the presence of two cellular pattern recognition receptors (PRRs), RIG-I and MDA5. No type I IFN response is induced in their absence. The presence of either of these PRRs is sufficient for detecting virus replication. However, type I IFN activation in response to pathogenic alphaviruses depends on the basal levels of RIG-I or MDA5. - Highlights: • Both RIG-I and MDA5 detect alphavirus replication. • Alphavirus-induced transcriptional shutoff affects type I IFN induction. • Sensing of alphavirus replication by RIG-I and MDA5 depends on their concentrations. • High basal level of RIG-I and MDA5 allows IFN induction by pathogenic alphaviruses. • This dependence determines the discrepancy between the in vivo and in vitro data.

  19. Monitoring network of atmospheric Radon-222 concentration in East Asia and backward trajectory analysis of Radon-222 concentration trend at a small solitary island on pacific ocean

    International Nuclear Information System (INIS)

    Ohkura, Takehisa; Yamazawa, Hiromi; Moriizumi, Jun; Hirao, Shigekazu; Iida, Takao; Guo Qiuju; Tohjima, Yasunori

    2009-01-01

    A monitoring network of atmospheric 222 Rn concentration as a tracer for long-range transport in East Asia was established. Atmospheric 222 Rn concentration at Beijing, which is located on China Continent was 10-20 Bq m -3 , at Nagoya, which is located on edge of terrestrial area was 3-10 Bq m -3 and at Hachijo-jima and Hateruma-jima, which are solitary islands in Pacific Ocean was 0.5-3 Bq m -3 , respectively. The atmospheric 222 Rn concentration variations were different from sites. The 222 Rn concentration was the lowest in the summer and the highest in the winter except Nagoya where the highest was observed in the autumn and the lowest in the spring. Diurnal variations were measured at Beijing and Nagoya. In contrast, diurnal variations were not measured but several-day-cycle variations were measured at Hachijo-jima and Hateruma-jima. It was pointed out by this study that the several-day-cycle variations at Hachijo-jima were dependent on synoptic-scale atmospheric disturbance. 222 Rn concentration increased rapidly after a cold front passed through Hachijo-jima. Backward trajectory analysis of the relationship between atmospheric 222 Rn concentrations at Hachijo-jima and transport pathway of air mass indicates that air mass transported from China and Siberia has high concentration 222 Rn and air mass transported from Pacific Ocean has low concentration 222 Rn. In winter, atmospheric 222 Rn concentrations at Hachijo-jima is dependent on vertical transport pathway rather than horizontal transport pathway. (author)

  20. Medically relevant assays with a simple smartphone and tablet based fluorescence detection system.

    Science.gov (United States)

    Wargocki, Piotr; Deng, Wei; Anwer, Ayad G; Goldys, Ewa M

    2015-05-20

    Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  1. Medically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System

    Directory of Open Access Journals (Sweden)

    Piotr Wargocki

    2015-05-01

    Full Text Available Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  2. Concentrations of radionuclides in fish collected from Bikini Atoll between 1977 and 1984

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Jokela, T.A.; Brunk, J.A.

    1986-07-01

    This report summarizes all available data on the concentrations of radionuclides in fish from Bikini Atoll between 1977 and 1984. As found in other global studies, /sup 137/Cs is most highly accumulated in edible flesh of all species of fish, the lowest fractions are found in the bone or liver. The mean concentration of /sup 137/Cs in muscle of reef fish from the southern part of the atoll is comparable to the global fallout concentration measured in market samples of fish collected from Chicago, Illinois, in 1982. /sup 90/Sr is generally associated with non-edible parts of fish, such as bone or viscera. Twenty-five to fifty percent of the total body burden of /sup 60/Co is accumulated in the muscle tissue; the remainder is distributed among the liver, skin, and viscera. The mean concentration of /sup 60/Co in fish has been decreasing at a rate faster than radiological decay alone. Most striking is the range of /sup 207/Bi concentrations among different species of fish collected at the same time and place. Highest concentrations of /sup 207/Bi were consistently detected in the muscle (and other tissues) of goatfish and some of the pelagic lagoon fish. In other reef fish, such as mullet, surgeonfish, and parrotfish, /sup 207/Bi was usually below detection limits by gamma spectrometry. Over 70% of the whole-body activity of /sup 207/Bi in goatfish is associated with the muscle tissue, whereas less than 5% is found in the muscle of mullet and surgeonfish. Neither /sup 239 +240/Pu nor /sup 241/Am is significantly accumulated in the muscle tissue of any species of fish. Apparently, /sup 238/Pu is in a more readily available form for accumulation by fishes than /sup 239 +240/Pu. Based on a daily ingestion rate of 200 q of fish flesh, dose rates to individuals through the fish-food ingestion pathway are well below current Federal guidelines.

  3. Zinc concentrations in marine macroalgae and a lichen from western Ireland in relation to phylogenetic grouping, habitat and morphology

    International Nuclear Information System (INIS)

    Stengel, Dagmar B.; Macken, Ailbhe; Morrison, Liam; Morley, Nicholas

    2004-01-01

    Zinc concentrations in 19 species of marine macroalgae and a lichen from western Ireland (Spiddal, Co. Galway) were analysed by atomic absorption spectrophotometry. Algae were collected from a single site but occupied different shore levels and belonged to distinct phylogenetic groupings and to different (previously recognised) morphological groups. Concentrations ranged from 15-115 μg g -1 dry weight. The greatest variation in concentration occurred amongst the red algal species, containing both maximum and minimum concentrations. Zn concentrations in brown and green algae were generally lower than those in red algae. When grouped according to thallus morphology, thin, branched sheets (which consisted mainly of red algae) contained the highest Zn concentrations. In filamentous algae, Zn levels were higher than in thick-leathery or coarsely branched algae. However, all green algal species examined had similar Zn concentrations, despite their different morphologies. In brown algae, the highest Zn levels were detected in mid-shore fucoids (Fucus vesiculosus and Fucus serratus), while thicker, subtidal and low-shore brown algae (Laminaria digitata, Halydris siliquosa) exhibited lower Zn concentrations. The lowest Zn concentrations were detected in high-intertidal species (Fucus spiralis, Pelvetia canaliculata), the only marine lichen examined (Ramalina siliquosa) and a red crustose alga (Corallina officinalis). In all morphological groups, red algal representatives contained relatively higher levels of Zn, the exception being Corallina officinalis. Zn levels in 4 species from a second, estuarine site in Galway Bay exhibited the same relative differences amongst species, but were all consistently higher than in algae from Spiddal. It is concluded that Zn accumulation in macroalgae is closely related to ecological growth strategies, following a functional-form model. However, the phylogenetic origin of species which determines carbohydrate and phenol composition, and

  4. Zinc concentrations in marine macroalgae and a lichen from western Ireland in relation to phylogenetic grouping, habitat and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Stengel, Dagmar B.; Macken, Ailbhe; Morrison, Liam; Morley, Nicholas

    2004-05-01

    Zinc concentrations in 19 species of marine macroalgae and a lichen from western Ireland (Spiddal, Co. Galway) were analysed by atomic absorption spectrophotometry. Algae were collected from a single site but occupied different shore levels and belonged to distinct phylogenetic groupings and to different (previously recognised) morphological groups. Concentrations ranged from 15-115 {mu}g g{sup -1} dry weight. The greatest variation in concentration occurred amongst the red algal species, containing both maximum and minimum concentrations. Zn concentrations in brown and green algae were generally lower than those in red algae. When grouped according to thallus morphology, thin, branched sheets (which consisted mainly of red algae) contained the highest Zn concentrations. In filamentous algae, Zn levels were higher than in thick-leathery or coarsely branched algae. However, all green algal species examined had similar Zn concentrations, despite their different morphologies. In brown algae, the highest Zn levels were detected in mid-shore fucoids (Fucus vesiculosus and Fucus serratus), while thicker, subtidal and low-shore brown algae (Laminaria digitata, Halydris siliquosa) exhibited lower Zn concentrations. The lowest Zn concentrations were detected in high-intertidal species (Fucus spiralis, Pelvetia canaliculata), the only marine lichen examined (Ramalina siliquosa) and a red crustose alga (Corallina officinalis). In all morphological groups, red algal representatives contained relatively higher levels of Zn, the exception being Corallina officinalis. Zn levels in 4 species from a second, estuarine site in Galway Bay exhibited the same relative differences amongst species, but were all consistently higher than in algae from Spiddal. It is concluded that Zn accumulation in macroalgae is closely related to ecological growth strategies, following a functional-form model. However, the phylogenetic origin of species which determines carbohydrate and phenol composition

  5. Analysis of serotonin concentrations in human milk by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Chiba, Takeshi; Maeda, Tomoji; Tairabune, Tomohiko; Tomita, Takashi; Sanbe, Atsushi; Takeda, Rika; Kikuchi, Akihiko; Kudo, Kenzo

    2017-03-25

    Serotonin (5-hydroxytryptamine, 5-HT) plays an important role in milk volume homeostasis in the mammary gland during lactation; 5-HT in milk may also affect infant development. However, there are few reports on 5-HT concentrations in human breast milk. To address this issue, we developed a simple method based on high-performance liquid chromatography with fluorescence detection (HPLC-FD) for measuring 5-HT concentrations in human breast milk. Breast milk samples were provided by four healthy Japanese women. Calibration curves for 5-HT in each sample were prepared with the standard addition method between 5 and 1000 ng/ml, and all had correlation coefficients >0.999. The recovery of 5-HT was 96.1%-101.0%, with a coefficient of variation of 3.39%-8.62%. The range of 5-HT concentrations estimated from the calibration curves was 11.1-51.1 ng/ml. Thus, the HPLC-FD method described here can effectively extract 5-HT from human breast milk with high reproducibility. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations

    Science.gov (United States)

    Ma, Wei-Jhe; Luo, Ching-Hsing; Lin, Jiun-Ling; Chou, Sin-Houng; Chen, Ping-Hung; Syu, Mei-Jywan; Kuo, Shin-Hung; Lai, Shin-Chi

    2016-01-01

    This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10−4 to 3.16 × 10−2 M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R2 = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications. PMID:27049390

  7. A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations

    Directory of Open Access Journals (Sweden)

    Wei-Jhe Ma

    2016-04-01

    Full Text Available This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA was used to measure and amplify the open-circuit potential (OCP between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10−4 to 3.16 × 10−2 M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R2 = 0.995. This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h for at least four days. Accordingly, its use is feasible and even promising for home-care applications.

  8. Structure of the lowest excited 0/sup +/ rotational band of /sup 16/O

    Energy Technology Data Exchange (ETDEWEB)

    Ikebata, Yasuhiko; Suekane, Shota

    1983-10-01

    The structure of the lowest excited 0/sup +/ rotational band is investigated by using the extended Nilsson model wave functions with angular momentum projection and the B1 interaction, two-body LS-force of the Skyrme type and the Coulomb interaction. The results obtained show good agreement with energy interval in this band.

  9. Extra-large pore zeolite (ITQ-40) with the lowest framework density containing double four- and double three-rings

    Science.gov (United States)

    Díaz-Cabañas, M. J.; Jiang, J.; Afeworki, M.; Dorset, D. L.; Soled, S. L.; Strohmaier, K. G.

    2010-01-01

    The first zeolite structure (ITQ-40) that contains double four (D4) and double three (D3) member ring secondary building units has been synthesized by introducing Ge and NH4F and working in concentrated synthesis gels. It is the first time that D3-Rs have been observed in a zeolite structure. As was previously analyzed [Brunner GO, Meier, WM (1989) Nature 337:146–147], such a structure has a very low framework density (10.1 T/1,000 Å3). Indeed, ITQ-40 has the lowest framework density ever achieved in oxygen-containing zeolites. Furthermore, it contains large pore openings, i.e., 15-member rings parallel to the [001] hexagonal axis and 16-member ring channels perpendicular to this axis. The results presented here push ahead the possibilities of zeolites for uses in electronics, control delivery of drugs and chemicals, as well as for catalysis. PMID:20660773

  10. Assessment of eight HPV vaccination programs implemented in lowest income countries

    Directory of Open Access Journals (Sweden)

    Ladner Joël

    2012-05-01

    Full Text Available Abstract Background Cervix cancer, preventable, continues to be the third most common cancer in women worldwide, especially in lowest income countries. Prophylactic HPV vaccination should help to reduce the morbidity and mortality associated with cervical cancer. The purpose of the study was to describe the results of and key concerns in eight HPV vaccination programs conducted in seven lowest income countries through the Gardasil Access Program (GAP. Methods The GAP provides free HPV vaccine to organizations and institutions in lowest income countries. The HPV vaccination programs were entirely developed, implemented and managed by local institutions. Institutions submitted application forms with institution characteristics, target population, communication delivery strategies. After completion of the vaccination campaign (3 doses, institutions provided a final project report with data on doses administered and vaccination models. Two indicators were calculated, the program vaccination coverage and adherence. Qualitative data were also collected in the following areas: government and community involvement; communication, and sensitization; training and logistics resources, and challenges. Results A total of eight programs were implemented in seven countries. The eight programs initially targeted a total of 87,580 girls, of which 76,983 received the full 3-dose vaccine course, with mean program vaccination coverage of 87.8%; the mean adherence between the first and third doses of vaccine was 90.9%. Three programs used school-based delivery models, 2 used health facility-based models, and 3 used mixed models that included schools and health facilities. Models that included school-based vaccination were most effective at reaching girls aged 9-13 years. Mixed models comprising school and health facility-based vaccination had better overall performance compared with models using just one of the methods. Increased rates of program coverage and

  11. Assessment of eight HPV vaccination programs implemented in lowest income countries.

    Science.gov (United States)

    Ladner, Joël; Besson, Marie-Hélène; Hampshire, Rachel; Tapert, Lisa; Chirenje, Mike; Saba, Joseph

    2012-05-23

    Cervix cancer, preventable, continues to be the third most common cancer in women worldwide, especially in lowest income countries. Prophylactic HPV vaccination should help to reduce the morbidity and mortality associated with cervical cancer. The purpose of the study was to describe the results of and key concerns in eight HPV vaccination programs conducted in seven lowest income countries through the Gardasil Access Program (GAP). The GAP provides free HPV vaccine to organizations and institutions in lowest income countries. The HPV vaccination programs were entirely developed, implemented and managed by local institutions. Institutions submitted application forms with institution characteristics, target population, communication delivery strategies. After completion of the vaccination campaign (3 doses), institutions provided a final project report with data on doses administered and vaccination models. Two indicators were calculated, the program vaccination coverage and adherence. Qualitative data were also collected in the following areas: government and community involvement; communication, and sensitization; training and logistics resources, and challenges. A total of eight programs were implemented in seven countries. The eight programs initially targeted a total of 87,580 girls, of which 76,983 received the full 3-dose vaccine course, with mean program vaccination coverage of 87.8%; the mean adherence between the first and third doses of vaccine was 90.9%. Three programs used school-based delivery models, 2 used health facility-based models, and 3 used mixed models that included schools and health facilities. Models that included school-based vaccination were most effective at reaching girls aged 9-13 years. Mixed models comprising school and health facility-based vaccination had better overall performance compared with models using just one of the methods. Increased rates of program coverage and adherence were positively correlated with the number of

  12. High-resolution carbon dioxide concentration record 650,000-800,000 years before present

    Energy Technology Data Exchange (ETDEWEB)

    Luthi, D; Bereiter, B; Blunier, T; Siegenthaler, U; Kawamura, K; Stocker, T F [Climate and Environm. Physics, Physics Inst., Univ. Bern, CH-3012 Bern, (Switzerland); Luthi, D; Bereiter, B; Blunier, T; Siegenthaler, U; Kawamura, K; Stocker, T F [Oeschger Centre for Climate Change Research, Univ. Bern, CH-3012 Bern, (Switzerland); Le Floch, M; Barnola, J M; Raynaud, D [LGGE, CNRS-Univ. Grenoble 1, F-38402 Saint Martin d' Heres, (France); Jouzel, J [Inst. Pierre Simon Laplace, LSCE, CEA-CNRS-Universite Versailles-Saint Quentin, CEA Saclay, F-91191 Gif sur Yvette (France); Fischer, H [Alfred Wegener Inst. for Polar and Maine Research, D-27568 Bremerhaven, (Germany)

    2008-07-01

    Changes in past atmospheric carbon dioxide concentrations can be determined by measuring the composition of air trapped in ice cores from Antarctica. So far, the Antarctic Vostok and EPICA Dome C ice cores have provided a composite record of atmospheric carbon dioxide levels over the past 650,000 years. Here we present results of the lowest 200 m of the Dome C ice core, extending the record of atmospheric carbon dioxide concentration by two complete glacial cycles to 800,000 yr before present. From previously published data and the present work, we find that atmospheric carbon dioxide is strongly correlated with Antarctic temperature throughout eight glacial cycles but with significantly lower concentrations between 650,000 and 750,000 yr before present. Carbon dioxide levels are below 180 parts per million by volume (p.p.m.v.) for a period of 3,000 yr during Marine Isotope Stage 16, possibly reflecting more pronounced oceanic carbon storage. We report the lowest carbon dioxide concentration measured in an ice core, which extends the pre-industrial range of carbon dioxide concentrations during the late Quaternary by about 10 p.p.m.v. to 172-300 p.p.m.v. (authors)

  13. Projection-operator calculations of the lowest e--He resonance

    International Nuclear Information System (INIS)

    Berk, A.; Bhatia, A.K.; Junker, B.R.; Temkin, A.

    1986-01-01

    Results for the lowest (Schulz) autodetaching state of He - [1s(2s) 2 ] are reported. The calculation utilizes the full projection-operator formalism as explicitly developed by Temkin and Bhatia [Phys. Rev. A 31, 1259 (1985)]. Eigenvalues, scrE = , are calculated using projection operators Q depending on increasingly elaborate target wave functions going up to a 10-term Hylleraas-form, and a configuration-interaction total wave function Phi of 40 configurations. Results are well converged, but our best value is --0.13 eV above the experimental position at 19.37 eV. We conclude that the shift (Δ) in the Feshbach formalism gives a large contribution (relative to the width) to the position E/sub r/ ( = scrE+Δ). An appendix is devoted to the evaluation of the most complicated type of three-center integral involved in the calculation

  14. Through-container, extremely low concentration detection of multiple chemical markers of counterfeit alcohol using a handheld SORS device.

    Science.gov (United States)

    Ellis, David I; Eccles, Rebecca; Xu, Yun; Griffen, Julia; Muhamadali, Howbeer; Matousek, Pavel; Goodall, Ian; Goodacre, Royston

    2017-09-21

    Major food adulteration incidents occur with alarming frequency and are episodic, with the latest incident, involving the adulteration of meat from 21 producers in Brazil supplied to 60 other countries, reinforcing this view. Food fraud and counterfeiting involves all types of foods, feed, beverages, and packaging, with the potential for serious health, as well as significant economic and social impacts. In the spirit drinks sector, counterfeiters often 'recycle' used genuine packaging, or employ good quality simulants. To prove that suspect products are non-authentic ideally requires accurate, sensitive, analysis of the complex chemical composition while still in its packaging. This has yet to be achieved. Here, we have developed handheld spatially offset Raman spectroscopy (SORS) for the first time in a food or beverage product, and demonstrate the potential for rapid in situ through-container analysis; achieving unequivocal detection of multiple chemical markers known for their use in the adulteration and counterfeiting of Scotch whisky, and other spirit drinks. We demonstrate that it is possible to detect a total of 10 denaturants/additives in extremely low concentrations without any contact with the sample; discriminate between and within multiple well-known Scotch whisky brands, and detect methanol concentrations well below the maximum human tolerable level.

  15. Lowest-energy cage structures of medium-sized (ZnO){sub n} clusters with n = 15 − 24

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Lingli; Sai, Linwei [School of Mathematical Sciences, Dalian University of Technology, Dalian 116024, China and College of Advanced Science and Technology, Dalian University of Technology, Dalian 116024 (China); Zhao, Jijun, E-mail: zhaojj@dlut.edu.cn [College of Advanced Science and Technology, Dalian University of Technology, Dalian 116024, China and Key Laboratory of Materials Modification by Laser, Ion and Electron Beams (Dalian University of Technology), Ministry of Education, Dalian 116024 (China); Qiu, Ruifeng [School of Mathematical Sciences, Dalian University of Technology, Dalian 116024 (China)

    2015-01-22

    Fullerene-like cage structures of medium-sized (ZnO){sub n} clusters with n = 15 − 24 were generated by spiral algorithm and optimized using density functional theory calculations. Most of these lowest-energy cage structures contain only four-membered and six-membered rings, whereas eight-membered rings were found in the lowest-energy cages of (ZnO){sub n} (n = 19, 20, 23, 24). Our best cage configurations either reproduce or prevail the previously reported ones. The size-dependent electronic properties were also discussed.

  16. Plasma concentrations and intakes of amino acids in male meat-eaters, fish-eaters, vegetarians and vegans: a cross-sectional analysis in the EPIC-Oxford cohort.

    Science.gov (United States)

    Schmidt, J A; Rinaldi, S; Scalbert, A; Ferrari, P; Achaintre, D; Gunter, M J; Appleby, P N; Key, T J; Travis, R C

    2016-03-01

    We aimed to investigate the differences in plasma concentrations and in intakes of amino acids between male meat-eaters, fish-eaters, vegetarians and vegans in the Oxford arm of the European Prospective Investigation into Cancer and Nutrition. This cross-sectional analysis included 392 men, aged 30-49 years. Plasma amino acid concentrations were measured with a targeted metabolomic approach using mass spectrometry, and dietary intake was assessed using a food frequency questionnaire. Differences between diet groups in mean plasma concentrations and intakes of amino acids were examined using analysis of variance, controlling for potential confounding factors and multiple testing. In plasma, concentrations of 6 out of 21 amino acids varied significantly by diet group, with differences of -13% to +16% between meat-eaters and vegans. Concentrations of methionine, tryptophan and tyrosine were highest in fish-eaters and vegetarians, followed by meat-eaters, and lowest in vegans. A broadly similar pattern was seen for lysine, whereas alanine concentration was highest in fish-eaters and lowest in meat-eaters. For glycine, vegans had the highest concentration and meat-eaters the lowest. Intakes of all 18 dietary amino acids differed by diet group; for the majority of these, intake was highest in meat-eaters followed by fish-eaters, then vegetarians and lowest in vegans (up to 47% lower than in meat-eaters). Men belonging to different habitual diet groups have significantly different plasma concentrations of lysine, methionine, tryptophan, alanine, glycine and tyrosine. However, the differences in plasma concentrations were less marked than and did not necessarily mirror those seen for amino acid intakes.

  17. MicroCantilever (MC) based nanomechanical sensor for detection of molecular interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyung [Iowa State Univ., Ames, IA (United States)

    2011-01-01

    hybridization and the conventional mode for cocaine detection, the lowest detectable concentration was determined by binding activity between the ligand and receptor molecules. In order to overcome this limitation for cocaine detection, a novel competition sensing mode that relies on rate of aptamers unbinding from the cantilever due to either diffusion or reaction with cocaine as target ligands in solution was investigated. The rate of unbinding is found to be dependent on the concentration of cocaine molecules. A model based on diffusion-reaction equation was developed to explain the experimental observation. Experimental results indicate that the competition mode reduces the lowest detectable threshold to 200 nM which is comparable to that achieved analytical techniques such as mass spectrometry.

  18. Electrochemical Sandwich Immunoassay for the Ultrasensitive Detection of Human MUC1 Cancer Biomarker

    Directory of Open Access Journals (Sweden)

    Zahra Taleat

    2013-01-01

    Full Text Available A new electrochemical sandwich immunoassay for the ultrasensitive detection of human MUC1 cancer biomarker using protein G-functionalized magnetic beads (MBs and graphite-based screen-printed electrodes (SPEs was developed. Magnetic beads were employed as the platforms for the immobilization and immunoreaction process. A pair of primary and secondary antibodies was used to capture the MUC1 protein. After labeling with a third antibody conjugated with horseradish peroxidase (HRP, the resulting conjugate was trapped at the surface of the graphite-based SPEs and MUC1 determination was carried out by differential pulse voltammetry (DPV at 0.4 V upon H2O2 addition using acetaminophen (APAP as the redox mediator. A linear relationship was obtained for the detection of human MUC1 over a range of 0–25 ppb with the lowest detection limit of 1.34 ppb when HRP was applied as a label. Preliminary experiments were performed using disposable electrochemical sensors in order to optimize some parameters (i.e., incubation times, concentrations, and blocking agent.

  19. A sub-nationwide survey of outdoor and indoor 222Rn concentrations in China by passive method

    International Nuclear Information System (INIS)

    Jin Yihe; Ikebe, Y.; Iida, T.

    1996-01-01

    From Nov. 1988 to Mar. 1993, cooperated by China and Japan, a survey of outdoor and indoor 222 Rn concentrations in 10 cities which were highly populated in China was carried out by means of passive method. the annual mean of outdoor 222 Rn concentration in 10 cities was 8.8 Bq·m -3 . The highest of 13.5 Bq·m -3 was in Wuhan, the lowest of 3.3 Bq·m -3 was in Chongming Island of Shanghai; and there were no significant differences among the different years in the same areas. During the northwest wind seasons, about 50% of outdoor 222 Rn concentration in Taiwan was contributed by the airflow from the mainland. Typical apartment houses and offices built of brick and concrete were also surveyed for indoor 222 Rn concentration. The annual mean of indoor 222 Rn concentration in the 10 cities was 19.5 Bq·m - 3. The highest of 33.9 Bq·m -3 was observed in Guiyang, the lowest of 9.0 Bq·m -3 was observed in Chongming Island of Shanghai. The outdoor and indoor 222 Rn concentrations showed a clear seasonal pattern with the minimum in summer and the maximum in winter. And they also showed a clear geographic distribution tendency; they were higher in inland than in seashores, and higher in the south than in the north. The ratios of indoor to outdoor 222 Rn concentrations were from 1.1 to 4.6. The annual effective dose equivalents resulting from outdoor and indoor 222 Rn concentrations amounted to about 0.64 mSv·a -1 . The highest was in Guiyang, and the lowest was in Nantong, being 1.12 and 0.39 mSv·a -1 , respectively

  20. A new HPLC method for the detection of iodine applied to natural samples of edible seaweeds and commercial seaweed food products.

    Science.gov (United States)

    Nitschke, Udo; Stengel, Dagmar B

    2015-04-01

    Rich in micronutrients and considered to contain high iodine levels, seaweeds have multiple applications as food/supplements and nutraceuticals with potential health implications. Here, we describe the development and validation of a new analytical method to quantify iodine as iodide (I(-)) using an isocratic HPLC system with UV detection; algal iodine was converted to I(-) via dry alkaline incineration. The method was successfully applied to 19 macroalgal species from three taxonomic groups and five commercially available seaweed food products. Fesh kelps contained highest levels, reaching >1.0% per dry weight (DW), but concentrations differed amongst thallus parts. In addition to kelps, other brown (Fucales: ∼ 0.05% DW) and some red species (∼ 0.05% DW) can also serve as a rich source of iodine; lowest iodine concentrations were detected in green macroalgae (∼ 0.005% DW), implying that quantities recommended for seaweed consumption may require species-specific re-evaluation to reach adequate daily intake levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Search for the lowest irradiation dose from literatures on radiation-induced cancer in uterus

    International Nuclear Information System (INIS)

    Yoshizawa, Yasuo; Kusama, Tomoko

    1975-01-01

    A survey of past case reports on radiation-induced cancer of the uterus was carried out with the main object of finding the lowest irradiation dose. Search of literature published since 1912 revealed 548 cases of radiation-induced cancer of the uterus. All of these cases of radiation-induced cancer had received radiation for the treatment of non-malignant disease. The primary gynecological conditions which were the object of radiation therapy were functional bleeding, endometrial hyperplasia, myoma, endometritis, and polyps. The lowest irradiation dose was estimated at 1000-1450 rad in the case of external X-ray irradiation, and 100 mg.hr for intrauterine radium therapy, which corresponds to 100-1000 rad. It was noted that were more cases of corpus cancer than cervical cancer. Histopathological findings of radiation-induced uterine cancer were carcinoma, sarcoma, and mixed mesodermal tumors. The latent period was distributed in the range of 1 to 40 years, with the average of 10.1 years. (auth.)

  2. Anthropogenic lead concentrations and sources in Baltic Sea sediments based on lead isotopic composition

    International Nuclear Information System (INIS)

    Zaborska, Agata

    2014-01-01

    Highlights: • Pb concentrations reach even 147 μg/g at Gdansk Basin sediments. • Marine sediments deposited before 1860 are not contaminated by Pb. • Contemporary inventories of anthropogenic Pb in marine sediments was of 0.5–11 g for m 2 . • The lowest 206 Pb/ 207 Pb (1.165) were measured in sediments deposited between 1970s–90s. • Coal burning was always the most important Pb source in Poland. - Abstract: The Gulf of Gdańsk is influenced by heavy metals of anthropogenic origin. In this study, temporal concentration changes of Pb, Zn, Cd, and Cu were studied in six, 50 cm long sediment cores. The main aim of the study was to concentrate on the history of Pb fluxes and Pb isotopic composition ( 206 Pb/ 207 Pb and 208 Pb/ 206 Pb) to trace Pb sources. The lowest Pb concentrations (19 μg g −1 ) were measured in sediments deposited circa 1860, while the highest Pb concentrations (63–147 μg g −1 ) were measured in sediments deposited between 1960s and 70s. Pre-industrial Pb fluxes were 7 Pb m 2 year −1 , while after WWII they reached 199 Pb m 2 year −1 . Highest 206 Pb/ 207 Pb ratios (∼1.22) were measured in the oldest sediment layers, and the lowest 206 Pb/ 207 Pb ratios (∼1.165) were measured in the sediments deposited in 1970s–90s. During the period of highest Pb contamination, the anthropogenic Pb fraction reached up to 93%. A general discussion of the Pb sources, emissions, and loads for Poland is included

  3. Multisite study of particle number concentrations in urban air.

    Science.gov (United States)

    Harrison, Roy M; Jones, Alan M

    2005-08-15

    Particle number concentration data are reported from a total of eight urban site locations in the United Kingdom. Of these, six are central urban background sites, while one is an urban street canyon (Marylebone Road) and another is influenced by both a motorway and a steelworks (Port Talbot). The concentrations are generally of a similar order to those reported in the literature, although higher than those in some of the other studies. Highest concentrations are at the Marylebone Road site and lowest are at the Port Talbot site. The central urban background locations lie somewhere between with concentrations typically around 20 000 cm(-3). A seasonal pattern affects all sites, with highest concentrations in the winter months and lowest concentrations in the summer. Data from all sites show a diurnal variation with a morning rush hour peak typical of an anthropogenic pollutant. When the dilution effects of windspeed are accounted for, the data show little directionality at the central urban background sites indicating the influence of sources from all directions as might be expected if the major source were road traffic. At the London Marylebone Road site there is high directionality driven by the air circulation in the street canyon, and at the Port Talbot site different diurnal patterns are seen for particle number count and PM10 influenced by emissions from road traffic (particle number count) and the steelworks (PM10) and local meteorological factors. Hourly particle number concentrations are generally only weakly correlated to NO(x) and PM10, with the former showing a slightly closer relationship. Correlations between daily average particle number count and PM10 were also weak. Episodes of high PM10 concentration in summer typically show low particle number concentrations consistent with transport of accumulation mode secondary aerosol, while winter episodes are frequently associated with high PM10 and particle number count arising from poor dispersion of

  4. MSFIA-LOV system for {sup 226}Ra isolation and pre-concentration from water samples previous radiometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, Rogelio [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Borràs, Antoni [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Leal, Luz [Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Cerdà, Víctor [Department of Chemistry, University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Ferrer, Laura, E-mail: laura.ferrer@uib.es [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain)

    2016-03-10

    An automatic system based on multisyringe flow injection analysis (MSFIA) and lab-on-valve (LOV) flow techniques for separation and pre-concentration of {sup 226}Ra from drinking and natural water samples has been developed. The analytical protocol combines two different procedures: the Ra adsorption on MnO{sub 2} and the BaSO{sub 4} co-precipitation, achieving more selectivity especially in water samples with low radium levels. Radium is adsorbed on MnO{sub 2} deposited on macroporous of bead cellulose. Then, it is eluted with hydroxylamine to transform insoluble MnO{sub 2} to soluble Mn(II) thus freeing Ra, which is then coprecipitated with BaSO{sub 4}. The {sup 226}Ra can be directly detected in off-line mode using a low background proportional counter (LBPC) or through a liquid scintillation counter (LSC), after performing an on-line coprecipitate dissolution. Thus, the versatility of the proposed system allows the selection of the radiometric detection technique depending on the detector availability or the required response efficiency (sample number vs. response time and limit of detection). The MSFIA-LOV system improves the precision (1.7% RSD), and the extraction frequency (up to 3 h{sup −1}). Besides, it has been satisfactorily applied to different types of water matrices (tap, mineral, well and sea water). The {sup 226}Ra minimum detectable activities (LSC: 0.004 Bq L{sup −1}; LBPC: 0.02 Bq L{sup −1}) attained by this system allow to reach the guidance values proposed by the relevant international agencies e.g. WHO, EPA and EC. - Highlights: • Automatic, rapid and selective method for {sup 226}Ra extraction/pre-concentration from water. • MSFIA-LOV system performs a sample clean-up prior to {sup 226}Ra radiometric detection. • {sup 226}Ra sample preparation allows using two radiometric detectors (LBPC and LSC). • Environmental levels of {sup 226}Ra are easily quantified. • High sensitivity and selectivity are achieved, reaching the

  5. Microcontroller based driver alertness detection systems to detect drowsiness

    Science.gov (United States)

    Adenin, Hasibah; Zahari, Rahimi; Lim, Tiong Hoo

    2018-04-01

    The advancement of embedded system for detecting and preventing drowsiness in a vehicle is a major challenge for road traffic accident systems. To prevent drowsiness while driving, it is necessary to have an alert system that can detect a decline in driver concentration and send a signal to the driver. Studies have shown that traffc accidents usually occur when the driver is distracted while driving. In this paper, we have reviewed a number of detection systems to monitor the concentration of a car driver and propose a portable Driver Alertness Detection System (DADS) to determine the level of concentration of the driver based on pixelated coloration detection technique using facial recognition. A portable camera will be placed at the front visor to capture facial expression and the eye activities. We evaluate DADS using 26 participants and have achieved 100% detection rate with good lighting condition and a low detection rate at night.

  6. Effect of terbutryn at environmental concentrations on early life stages of common carp (Cyprinus carpio L.)

    Czech Academy of Sciences Publication Activity Database

    Velíšek, J.; Stará, A.; Máchová, J.; Dvořák, P.; Zusková, E.; Prokeš, Miroslav; Svobodová, Z.

    2012-01-01

    Roč. 102, č. 1 (2012), s. 102-108 ISSN 0048-3575 Institutional research plan: CEZ:AV0Z60930519 Keywords : Triazine * Embryo–larval toxicity test * Lowest observed-effect concentration * No observed-effect concentration * Early development * Malformation Subject RIV: GL - Fishing Impact factor: 2.111, year: 2012

  7. Dual channel detection of ultra low concentration of bacteria in real time by scanning fluorescence correlation spectroscopy

    Science.gov (United States)

    Altamore, Ilaria; Lanzano, Luca; Gratton, Enrico

    2013-06-01

    We describe a novel method to detect very low concentrations of bacteria in water. Our device consists of a portable horizontal geometry small confocal microscope with large pinhole and a holder for cylindrical cuvettes containing the sample. Two motors provide fast rotational and slow vertical motion of the cuvette so the device looks like a simplified flow cytometer without flow. To achieve high sensitivity, the design has two detection channels. Bacteria are stained by two different nucleic acid dyes and excited with two different lasers. Data are analyzed with a correlation filter based on particle passage pattern recognition. The passage of a particle through the illumination volume is compared with a Gaussian pattern in both channels. The width of the Gaussian correlates with the time of passage of the particle so one particle is counted when the algorithm finds a match with a Gaussian in both channels. The concentration of particles in the sample is deduced from the total number of coincident hits and the total volume scanned. This portable setup provides higher sensitivity, low-cost advantage, and it can have a wide use ranging from clinical applications to pollution monitors and water and air quality control.

  8. Dual channel detection of ultra low concentration of bacteria in real time by scanning fluorescence correlation spectroscopy

    International Nuclear Information System (INIS)

    Altamore, Ilaria; Lanzano, Luca; Gratton, Enrico

    2013-01-01

    We describe a novel method to detect very low concentrations of bacteria in water. Our device consists of a portable horizontal geometry small confocal microscope with large pinhole and a holder for cylindrical cuvettes containing the sample. Two motors provide fast rotational and slow vertical motion of the cuvette so the device looks like a simplified flow cytometer without flow. To achieve high sensitivity, the design has two detection channels. Bacteria are stained by two different nucleic acid dyes and excited with two different lasers. Data are analyzed with a correlation filter based on particle passage pattern recognition. The passage of a particle through the illumination volume is compared with a Gaussian pattern in both channels. The width of the Gaussian correlates with the time of passage of the particle so one particle is counted when the algorithm finds a match with a Gaussian in both channels. The concentration of particles in the sample is deduced from the total number of coincident hits and the total volume scanned. This portable setup provides higher sensitivity, low-cost advantage, and it can have a wide use ranging from clinical applications to pollution monitors and water and air quality control. (paper)

  9. A label-free silicon quantum dots-based photoluminescence sensor for ultrasensitive detection of pesticides.

    Science.gov (United States)

    Yi, Yinhui; Zhu, Gangbing; Liu, Chang; Huang, Yan; Zhang, Youyu; Li, Haitao; Zhao, Jiangna; Yao, Shouzhuo

    2013-12-03

    Sensitive, rapid, and simple detection methods for the screening of extensively used organophosphorus pesticides and highly toxic nerve agents are in urgent demand. A novel label-free silicon quantum dots (SiQDs)-based sensor was designed for ultrasensitive detection of pesticides. This sensing strategy involves the reaction of acetylcholine chloride (ACh) with acetylcholinesterase (AChE) to form choline that is in turn catalytically oxidized by choline oxidase (ChOx) to produce betaine and H2O2 which can quench the photoluminescence (PL) of SiQDs. Upon the addition of pesticides, the activity of AChE is inhibited, leading to the decrease of the generated H2O2, and hence the PL of SiQDs increases. By measuring the increase in SiQDs PL, the inhibition efficiency of pesticide to AChE activity was evaluated. It was found that the inhibition efficiency was linearly dependent on the logarithm of the pesticides concentration. Consequently, pesticides, such as carbaryl, parathion, diazinon, and phorate, were determined with the SiQDs PL sensing method. The lowest detectable concentrations for carbaryl, parathion, diazinon, and phorate reached 7.25 × 10(-9), 3.25 × 10(-8), 6.76 × 10(-8), and 1.9 × 10(-7) g/L, respectively, which were much lower than those previously reported. The detecting results of pesticide residues in food samples via this method agree well with those from high-performance liquid chromatography. The simple strategy reported here should be suitable for on-site pesticides detection, especially in combination with other portable platforms.

  10. Effects of low concentrations of glyphosate-based herbicide factor 540® on an agricultural stream freshwater phytoplankton community.

    Science.gov (United States)

    Smedbol, Élise; Gomes, Marcelo Pedrosa; Paquet, Serge; Labrecque, Michel; Lepage, Laurent; Lucotte, Marc; Juneau, Philippe

    2018-02-01

    Residual glyphosate from glyphosate based herbicides (GBH) are ubiquitously detected in streams draining agricultural fields, and may affect phytoplankton communities present in these ecosystems. Here, the effects of the exposure (96 h) of a phytoplankton community collected in an agricultural stream to various glyphosate concentrations (1, 5, 10, 50, 100, 500 and 1000 μg l -1 ) of Factor 540 ® GBH were investigated. The lowest GBH concentration of 1 μg l -1 reduced chlorophyll a and carotenoid contents. Low glyphosate concentrations, such as 5 and 10 μg l -1 , promoted changes in the community's structure and reduced the diversity of the main algal species. At glyphosate concentrations ranging from 50 to 1000 μg l -1 , the phytoplankton community's composition was modified and new main species appeared. The highest glyphosate concentrations (500 and 1000 μg l -1 ) affected the shikimate content, the lipid peroxidation and the activity of antioxidant enzymes (superoxide dismutase, catalase and ascorbate peroxidase). These results indicate that GBH can modify structural and functional properties of freshwater phytoplankton communities living in streams located in agricultural areas at glyphosate concentrations much inferior to the 800 μg l -1 threshold set by the Canadian guidelines for the protection of aquatic life. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  11. Three-point Green's function of massless QED in position space to lowest order

    International Nuclear Information System (INIS)

    Mitra, Indrajit

    2009-01-01

    The transverse part of the three-point Green's function of massless QED is determined to the lowest order in position space. Taken together with the evaluation of the longitudinal part in Mitra (2008) (J. Phys. A: Math. Theor. 41 315401), this gives a relation for QED which is analogous to the star-triangle relation. We relate our result to conformal-invariant three-point functions

  12. Diurnal variations in milk macro-mineral concentrations in Holstein dairy cows in Urmia, Iran

    Directory of Open Access Journals (Sweden)

    Shahram Nozad

    2012-12-01

    Full Text Available Milk samples from high and low milk producer Holstein cows, were obtained during the morning and afternoon milking over a one week period. Overall, 1064 samples were tested within 14 times sampling in Urmia, Iran. Milk macro-mineral concentrations in the morning milking and in low producers were greater than in the afternoon and in high producers. The highest and lowest concentrations were observed in Na+ and Mg++, respectively. Mean milk values between low and high producers in the morning, afternoon and daily milking times were different (p < 0.05. The individual comparison of milk parameters between both groups in the different milking times were also different (p < 0.05. The results of correlation among macro-minerals in the morning, afternoon and overall milking showed significant and positive correlations among all macro-minerals except for Na+ and K+, in which there was a significant negative correlation (p < 0.05. The highest and lowest correlations were found between Ca++ and inorganic phosphorus (IP (r=0.37, p < 0.05 and Na+ and IP (r=0.10, p < 0.05, respectively. It is concluded that the concentration of macro-minerals in different producers varied between milking times. The sodium concentration was the highest while Mg++ was the lowest among macro-minerals. The correlation between Ca++/ IP was the highest, while Na+/K+ revealed a negative correlation. Therefore, by organizing the appropriate macro-minerals in the ration, it would be possible to achieve an optimal purpose from animal husbandry.

  13. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr_3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. - Highlights: • A small-sized UAV airborne sensor system was developed. • Three radioactive models were chosen to simulate the Fukushima accident. • Both the air and ground radiation were considered in the models. • The efficiency calculations and MDAC values were given. • The sensor system is able to monitor in serious nuclear accidents.

  14. Change in Body Mass Index Associated With Lowest Mortality in Denmark, 1976-2013.

    Science.gov (United States)

    Afzal, Shoaib; Tybjærg-Hansen, Anne; Jensen, Gorm B; Nordestgaard, Børge G

    2016-05-10

    Research has shown a U-shaped pattern in the association of body mass index (BMI) with mortality. Although average BMI has increased over time in most countries, the prevalence of cardiovascular risk factors may also be decreasing among obese individuals over time. Thus, the BMI associated with lowest all-cause mortality may have changed. To determine whether the BMI value that is associated with the lowest all-cause mortality has increased in the general population over a period of 3 decades. Three cohorts from the same general population enrolled at different times: the Copenhagen City Heart Study in 1976-1978 (n = 13,704) and 1991-1994 (n = 9482) and the Copenhagen General Population Study in 2003-2013 (n = 97,362). All participants were followed up from inclusion in the studies to November 2014, emigration, or death, whichever came first. For observational studies, BMI was modeled using splines and in categories defined by the World Health Organization. Body mass index was calculated as weight in kilograms divided by height in meters squared. Main outcome was all-cause mortality and secondary outcomes were cause-specific mortality. The number of deaths during follow-up was 10,624 in the 1976-1978 cohort (78% cumulative mortality; mortality rate [MR], 30/1000 person-years [95%CI, 20-46]), 5025 in the 1991-1994 cohort (53%; MR, 16/1000 person-years [95%CI, 9-30]), and 5580 in the 2003-2013 cohort (6%;MR, 4/1000 person-years [95%CI, 1-10]). Except for cancer mortality, the association of BMI with all-cause, cardiovascular, and other mortality was curvilinear (U-shaped). The BMI associated with the lowest all-cause mortality increased by 3.3 from the 1976-1978 cohort compared with the 2003-2013 cohort. [table: see text] The multivariable-adjusted hazard ratios for all-cause mortality for BMI of 30 or more vs BMI of 18.5 to 24.9 were 1.31 (95%CI, 1.23-1.39;MR, 46/1000 person-years [95%CI, 32-66] vs 28/1000 person-years [95%CI, 18-45]) in the 1976

  15. Does the Lowest Bid Price Evaluation Criterion Make for a More Efficient Public Procurement Selection Criterion? (Case of the Czech Republic

    Directory of Open Access Journals (Sweden)

    Ochrana František

    2015-06-01

    Full Text Available Through the institute of public procurement a considerable volume of financial resources is allocated. It is therefore in the interest of contracting entities to seek ways of how to achieve an efficient allocation of resources. Some public contract-awarding entities, along with some public-administration authorities in the Czech Republic, believe that the use of a single evaluation criterion (the lowest bid price results in a more efficient tender for a public contract. It was found that contracting entities in the Czech Republic strongly prefer to use the lowest bid price criterion. Within the examined sample, 86.5 % of public procurements were evaluated this way. The analysis of the examined sample of public contracts proved that the choice of an evaluation criterion, even the preference of the lowest bid price criterion, does not have any obvious impact on the final cost of a public contract. The study concludes that it is inappropriate to prefer the criterion of the lowest bid price within the evaluation of public contracts that are characterised by their complexity (including public contracts for construction works and public service contracts. The findings of the Supreme Audit Office related to the inspection of public contracts indicate that when using the lowest bid price as an evaluation criterion, a public contract may indeed be tendered with the lowest bid price, but not necessarily the best offer in terms of supplied quality. It is therefore not appropriate to use the lowest bid price evaluation criterion to such an extent for the purpose of evaluating work and services. Any improvement to this situation requires a corresponding amendment to the Law on Public Contracts and mainly a radical change in the attitude of the Office for the Protection of Competition towards proposed changes, as indicated within the conclusions and recommendations proposed by this study.

  16. The Lowest Spin and Parity Levels on Two Particle System for Odd-oddNuclei 60Co and 46K

    International Nuclear Information System (INIS)

    Wardhani, VIS; Siagian, Toga

    2000-01-01

    For obtaining the lowest spin and parity levels of odd-odd nuclei, theanalyzing of the nuclei 60 Co and 46 K has been done using delta forcemodel. The calculation is done by theoretically and compared with experiment.To get a result optimally, the data analyzed using least square method. It isshown that the lowest spin and parity level from calculation result and theexperiment result are similar. (author)

  17. Simulated minimum detectable activity concentration (MDAC) for a real-time UAV airborne radioactivity monitoring system with HPGe and LaBr_3 detectors

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    An automatic real-time UAV airborne radioactivity monitoring system with high-purity germanium (HPGe) and lanthanum bromide (LaBr_3) detectors (NH-UAV) was developed to precisely obtain small-scope nuclide information in major nuclear accidents. The specific minimum detectable activity concentration (MDAC) calculation method for NH-UAV in the atmospheric environment was deduced in this study for a priori evaluation and quantification of the suitability of NH-UAV in the Fukushima nuclear accident, where the MDAC values of this new equipment were calculated based on Monte Carlo simulation. The effects of radioactive source term size and activity concentration on the MDAC values were analyzed to assess the detection performance of NH-UAV in more realistic environments. Finally, the MDAC values were calculated at different shielding thicknesses of the HPGe detector to improve the detection capabilities of the HPGe detector, and the relationship between the MDAC and the acquisition time of the system was deduced. The MDAC calculation method and data results in this study may be used as a reference for in-situ radioactivity measurement of NH-UAV. - Highlights: • A real-time UAV airborne radioactivity monitoring system (NH-UAV) was developed. • The efficiency calculations and MDAC values are given. • NH-UAV is able to monitor major nuclear accidents, such as the Fukushima accident. • The source term size can influence the detection sensitivity of the system. • The HPGe detector possesses measurement thresholds on activity concentration.

  18. A sensitive method for the detection of tritium-marked {beta}-indolylacetic acid in plant cells and tissues at physiological and experimental concentrations (1962); Une methode sensible pour la detection de l'acide {beta}-indolylacetique marque au tritium, dans des cellules et tissus vegetaux a des concentrations physiologiques et experimentales (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Figier, J; Khau Van Kien, L; Roux, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    The localisation of {beta}-indolylacetic acid (A.I.A.), a growth auxin is attempted using nuclear indicators ({sup 14}C and tritium). The radio - auto-histographic detection method depends on the insolubilization of A.I.A. 'in situ' by picric acid and basic lead acetate at a suitable pH, the A.I.A. being protected from histological solvents. The results of the detections corresponding to physiological responses during growth tests on Pisum, Avena, Phascolus and Vicia, at concentrations of 10{sup -5} and higher make possible the localisation of tissues in agreement with the auxinic activity and with the relations already known between A.L.A. and cellular formations. By increasing the time of exposures of the sections, it will be possible to attain concentrations which are much lower and more clearly physiological. (authors) [French] La localisation de l'acide {beta}-indolylacetique (A.L.A.), auxine de croissance est abordee avec les indicateurs nucleaires ({sup 14}C et tritium). La methode de detection radio-autohistographique repose sur l'insolubilisation de l'A.I.A. 'in situ' par l'acide picrique et l'acetate basique de plomb a pH convenable, le mettant a l'abri des solvants histologiques. Les resultats des detections correspondant a des reponses physiologiques au cours de test de croissance sur Pisum, Avena, Phascolus et Vicia, a la concentration de 10{sup -5} et plus elevee permettent des localisations tissulaires concordant avec l'activite auxinique et les rapports deja connus de l'A.I.A. avec les formations cellulaires. En prolongeant la duree d'exposition des coupes, il sera possible de descendre a des concentrations bien plus faibles et plus nettement physiologiques. (auteurs)

  19. N-representability of the Jastrow wave function pair density of the lowest-order.

    Science.gov (United States)

    Higuchi, Katsuhiko; Higuchi, Masahiko

    2017-08-08

    Conditions for the N-representability of the pair density (PD) are needed for the development of the PD functional theory. We derive sufficient conditions for the N-representability of the PD that is calculated from the Jastrow wave function within the lowest order. These conditions are used as the constraints on the correlation function of the Jastrow wave function. A concrete procedure to search the suitable correlation function is also presented.

  20. Selective vancomycin detection using optical fibre long period gratings functionalised with molecularly imprinted polymer nanoparticles.

    Science.gov (United States)

    Korposh, Sergiy; Chianella, Iva; Guerreiro, Antonio; Caygill, Sarah; Piletsky, Sergey; James, Stephen W; Tatam, Ralph P

    2014-05-07

    An optical fibre long period grating (LPG) sensor modified with molecularly imprinted polymer nanoparticles (nanoMIPs) for the specific detection of antibiotics is presented. The operation of the sensor is based on the measurement of changes in refractive index induced by the interaction of nanoMIPs deposited onto the cladding of the LPG with free vancomycin (VA). The binding of nanoMIPs to vancomycin was characterised by a binding constant of 4.3 ± 0.1 × 10(-8) M. The lowest concentration of analyte measured by the fibre sensor was 10 nM. In addition, the sensor exhibited selectivity, as much smaller responses were obtained for high concentrations (∼700 μM) of other commonly prescribed antibiotics such as amoxicillin, bleomycin and gentamicin. In addition, the response of the sensor was characterised in a complex matrix, porcine plasma, spiked with 10 μM of VA.

  1. Detecting and Identifying Industrial Gases by a Method Based on Olfactory Machine at Different Concentrations

    Directory of Open Access Journals (Sweden)

    Yunlong Sun

    2018-01-01

    Full Text Available Gas sensors have been widely reported for industrial gas detection and monitoring. However, the rapid detection and identification of industrial gases are still a challenge. In this work, we measure four typical industrial gases including CO2, CH4, NH3, and volatile organic compounds (VOCs based on electronic nose (EN at different concentrations. To solve the problem of effective classification and identification of different industrial gases, we propose an algorithm based on the selective local linear embedding (SLLE to reduce the dimensionality and extract the features of high-dimensional data. Combining the Euclidean distance (ED formula with the proposed algorithm, we can achieve better classification and identification of four kinds of gases. We compared the classification and recognition results of classical principal component analysis (PCA, linear discriminate analysis (LDA, and PCA + LDA algorithms with the proposed SLLE algorithm after selecting the original data and performing feature extraction. The experimental results show that the recognition accuracy rate of the SLLE reaches 91.36%, which is better than the other three algorithms. In addition, the SLLE algorithm provides more efficient and accurate responses to high-dimensional industrial gas data. It can be used in real-time industrial gas detection and monitoring combined with gas sensor networks.

  2. False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, Wayne; Krauter, Paula A.; Boucher, Raymond M.; Tezak, Mathew; Amidan, Brett G. (Pacific Northwest National Laboratory, Richland, WA); Piepel, Greg F. (Pacific Northwest National Laboratory, Richland, WA)

    2011-05-01

    Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

  3. Search for the lowest irradiation dose from literatures on radiation-induced bone tumor

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T; Morimoto, K [Tokyo Univ. (Japan). Faculty of Medicine

    1977-04-01

    A survey of past case reports of bone tumor induced by external radiation was carried out with the main object of finding the lowest irradiation dose. Search of the literature published since 1922 revealed 262 cases of radiation-induced bone tumor. These patients, except a patient with occupational exposure, had received radiation for treatment. The primary conditions as object of radiation therapy were nonmalignan bone diseases such as tuberclosis, giant cell tumor, fibrous dysplasia and bone cyst, and extra-skeletal diseases such as retinoblastoma, breast cancer and uterus cancer. The ratio of male to female patients with radiation-induced bone tumor was 1:1.3. The age of the patient ranged between 5 and 98 years, with an average of 37.6 years. Skeletal distribution of radiation-induced bone tumor was as follows: 20% the frontal and face bones, 17% the femur, 10% the humerus, 9% the vertebral column, and 44% other. The lowest absorbed dose reported was 800 rads in patients irradiated for the treatment of bone disease, but 1800 rads in patients with extra-skeletal disease. The latent period ranged between 2 and 42 years, with an average of 11.7 years. The histopathological findings were as follows: 60% osteosarcoma, 25% fibrosarcoma, 7% chondrosarcoma, and 8% other.

  4. People in sub-Saharan Africa rate their health and health care among the lowest in the world.

    Science.gov (United States)

    Deaton, Angus S; Tortora, Robert

    2015-03-01

    The health of people in sub-Saharan Africa is a major global concern. However, data are weak, and little is known about how people in the region perceive their health or their health care. We used data from the Gallup World Poll in 2012 to document sub-Saharan Africans' perceived health status, their satisfaction with health care, their contact with medical professionals, and the priority they attach to health care. In comparison to other regions of the world, sub-Saharan Africa has the lowest ratings for well-being and the lowest satisfaction with health care. It also has the second-lowest perception of personal health, after only the former Soviet Union and its Eastern European satellites. HIV prevalence is positively correlated with perceived improvements in health care in countries with high prevalence. This is consistent with an improvement in at least some health care services as a result of the largely aid-funded rollout of antiretroviral treatment. Even so, sub-Saharan Africans do not prioritize health care as a matter of policy, although donors are increasingly shifting their aid efforts in the region toward health. Project HOPE—The People-to-People Health Foundation, Inc.

  5. Studies evaluating the applicability of utilizing the same concentration techniques for the detection of protozoan parasites and viruses in water

    CSIR Research Space (South Africa)

    Kfir, R

    1995-01-01

    Full Text Available sample volume to about 101. This study shows that concentration techniques utilised for the isolation of enteric viruses can also be applied for the detection of protozoan parasites from water. This procedure allows for co-analysis of both viruses...

  6. Lowest vibrational states of 4He3He+: Non-Born-Oppenheimer calculations

    International Nuclear Information System (INIS)

    Stanke, Monika; Bubin, Sergiy; Kedziera, Dariusz; Molski, Marcin; Adamowicz, Ludwik

    2007-01-01

    Very accurate quantum mechanical calculations of the first five vibrational states of the 4 He 3 He + molecular ion are reported. The calculations have been performed explicitly including the coupling of the electronic and nuclear motions [i.e., without assuming the Born-Oppenheimer (BO) approximation]. The nonrelativistic non-BO wave functions were used to calculate the α 2 relativistic mass velocity, Darwin, and spin-spin interaction corrections. For the lowest vibrational transition, whose experimental energy is established with high precision, the calculated and the experimental results differ by only 0.16 cm -1

  7. Use of a fractal-like gold nanostructure in surface-enhanced raman spectroscopy for detection of selected food contaminants.

    Science.gov (United States)

    He, Lili; Kim, Nam-Jung; Li, Hao; Hu, Zhiqiang; Lin, Mengshi

    2008-11-12

    The safety of imported seafood products because of the contamination of prohibited substances, including crystal violet (CV) and malachite green (MG), raised a great deal of concern in the United States. In this study, a fractal-like gold nanostructure was developed through a self-assembly process and the feasibility of using surface-enhanced Raman spectroscopy (SERS) coupled with this nanostructure for detection of CV, MG, and their mixture (1:1) was explored. SERS was capable of characterizing and differentiating CV, MG, and their mixture on fractal-like gold nanostructures quickly and accurately. The enhancement factor of the gold nanostructures could reach an impressive level of approximately 4 x 10(7), and the lowest detectable concentration for the dye molecules was at approximately 0.2 ppb level. These results indicate that SERS coupled with fractal-like gold nanostructures holds a great potential as a rapid and ultra-sensitive method for detecting trace amounts of prohibited substances in contaminated food samples.

  8. Toward in vivo detection of hydrogen peroxide with ultrasound molecular imaging

    Science.gov (United States)

    Olson, Emilia S.; Orozco, Jahir; Wu, Zhe; Malone, Christopher D.; Yi, Boemha; Gao, Wei; Eghtedari, Mohammad; Wang, Joseph; Mattrey, Robert F.

    2013-01-01

    We present a new class of ultrasound molecular imaging agents that extend upon the design of micromotors that are designed to move through fluids by catalyzing hydrogen peroxide (H2O2) and propelling forward by escaping oxygen microbubbles. Micromotor converters require 62 mm of H2O2 to move – 1000-fold higher than is expected in vivo. Here, we aim to prove that ultrasound can detect the expelled microbubbles, to determine the minimum H2O2 concentration needed for microbubble detection, explore alternate designs to detect the H2O2 produced by activated neutrophils and perform preliminary in vivo testing. Oxygen microbubbles were detected by ultrasound at 2.5 mm H2O2. Best results were achieved with a 400–500 nm spherical design with alternating surface coatings of catalase and PSS over a silica core. The lowest detection limit of 10–100 µm was achieved when assays were done in plasma. Using this design, we detected the H2O2 produced by freshly isolated PMA-activated neutrophils allowing their distinction from naïve neutrophils. Finally, we were also able to show that direct injection of these nanospheres into an abscess in vivo enhanced ultrasound signal only when they contained catalase, and only when injected into an abscess, likely because of the elevated levels of H2O2 produced by inflammatory mediators. PMID:23958028

  9. A colorimetric nitrite detection system with excellent selectivity and high sensitivity based on Ag@Au nanoparticles.

    Science.gov (United States)

    Li, Tianhua; Li, Yonglong; Zhang, Yujie; Dong, Chen; Shen, Zheyu; Wu, Aiguo

    2015-02-21

    Excessive uptake of NO2(-) is detrimental to human health, but the currently available methods used to sensitively detect this ion in the environment are cumbersome and expensive. In this study, we developed an improved NO2(-) detection system based on a redox etching strategy of CTAB-stabilized Ag-Au core-shell nanoparticles (Ag@AuNPs). The detection mechanism was verified by UV-Vis spectroscopy, TEM and XPS. The detection system produces a color change from purple to colorless in response to an increase of NO2(-) concentration. The selectivity of detection of NO2(-), both with the unaided eye and by measurement of UV-Vis spectra, is excellent in relation to other ions, including Cu(2+), Co(2+), Ni(2+), Cr(3+), Al(3+), Pb(2+), Cd(2+), Ca(2+), Ba(2+), Zn(2+), Mn(2+), Mg(2+), Fe(3+), Hg(2+), Ag(+), K(+), F(-), PO4(3-), C2O4(2-), SO3(2-), CO3(2-), SO4(2-), NO3(-) and CH3-COO(-) (Ac(-)). The limit of detection (LOD) for NO2(-) is 1.0 μM by eye and 0.1 μM by UV-Vis spectroscopy. The LOD by eye is lower than the lowest previously reported value (4.0 μM). There is a good linear relationship between A/A0 and the concentration of NO2(-) from 1.0 to 20.0 μM NO2(-), which permits a quantitative assay. The applicability of our detection system was also verified by analysis of NO2(-) in tap water and lake water. The results demonstrate that our Ag@AuNP-based detection system can be used for the rapid colorimetric detection of NO2(-) in complex environmental samples, with excellent selectivity and high sensitivity.

  10. A Switchable Linker-Based Immunoassay for Ultrasensitive Visible Detection of Salmonella in Tomatoes.

    Science.gov (United States)

    Hahn, Jungwoo; Kim, Eunghee; You, Young Sang; Gunasekaran, Sundaram; Lim, Seokwon; Choi, Young Jin

    2017-10-01

    On-site detection for sensitive identification of foodborne pathogens on fresh produce with minimal use of specialized instrumentation is crucial to the food industry. A switchable linker (SL)-based immunoassay was designed for ultrasensitive on-site detection of Salmonella in tomato samples. The assay is based on large-scale aggregation of gold nanoparticles (GNPs), induced by a quantitative relationship among the biotinylated Salmonella polyclonal antibody (b-Ab) used as the SL, the functionalized GNPs, and Salmonella. Important factors such as the concentration of SLs, time required for large-scale aggregation, and selectivity of b-Ab were optimized to minimize the detection time (within 45 min with gentle agitation) and achieve the lowest limit of detection (LOD; 10 CFU/g in tomato samples) possible. This SL-based immunoassay with its relatively low LOD and short detection time may meet the need for rapid, simple, on-site analysis of pathogens in fresh produce. The novel switchable linker-based immunoassay is a rapid, specific, and sensitive method that has potential applications for routine diagnostics of Salmonella in tomato products. These advantages make it a practical approach for general use in the processing industry to detect Salmonella rapidly and to implement appropriate regulatory procedures. Furthermore, it could be applied to other fresh products including cantaloupe, strawberry, and cucumbers. © 2017 Institute of Food Technologists®.

  11. Optimization of the elution buffer and concentration method for detecting hepatitis E virus in swine liver using a nested reverse transcription-polymerase chain reaction and real-time reverse transcription-polymerase chain reaction.

    Science.gov (United States)

    Son, Na Ry; Seo, Dong Joo; Lee, Min Hwa; Seo, Sheungwoo; Wang, Xiaoyu; Lee, Bog-Hieu; Lee, Jeong-Su; Joo, In-Sun; Hwang, In-Gyun; Choi, Changsun

    2014-09-01

    The aim of this study was to develop an optimal technique for detecting hepatitis E virus (HEV) in swine livers. Here, three elution buffers and two concentration methods were compared with respect to enhancing recovery of HEV from swine liver samples. Real-time reverse transcription-polymerase chain reaction (RT-PCR) and nested RT-PCR were performed to detect HEV RNA. When phosphate-buffered saline (PBS, pH 7.4) was used to concentrate HEV in swine liver samples using ultrafiltration, real-time RT-PCR detected HEV in 6 of the 26 samples. When threonine buffer was used to concentrate HEV using polyethylene glycol (PEG) precipitation and ultrafiltration, real-time RT-PCR detected HEV in 1 and 3 of the 26 samples, respectively. When glycine buffer was used to concentrate HEV using ultrafiltration and PEG precipitation, real-time RT-PCR detected HEV in 1 and 3 samples of the 26 samples, respectively. When nested RT-PCR was used to detect HEV, all samples tested negative regardless of the type of elution buffer or concentration method used. Therefore, the combination of real-time RT-PCR and ultrafiltration with PBS buffer was the most sensitive and reliable method for detecting HEV in swine livers. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. UV Absorption Spectroscopy in Water-Filled Antiresonant Hollow Core Fibers for Pharmaceutical Detection.

    Science.gov (United States)

    Nissen, Mona; Doherty, Brenda; Hamperl, Jonas; Kobelke, Jens; Weber, Karina; Henkel, Thomas; Schmidt, Markus A

    2018-02-06

    Due to a worldwide increased use of pharmaceuticals and, in particular, antibiotics, a growing number of these substance residues now contaminate natural water resources and drinking supplies. This triggers a considerable demand for low-cost, high-sensitivity methods for monitoring water quality. Since many biological substances exhibit strong and characteristic absorption features at wavelengths shorter than 300 nm, UV spectroscopy presents a suitable approach for the quantitative identification of such water-contaminating species. However, current UV spectroscopic devices often show limited light-matter interaction lengths, demand sophisticated and bulky experimental infrastructure which is not compatible with microfluidics, and leave large fractions of the sample analyte unused. Here, we introduce the concept of UV spectroscopy in liquid-filled anti-resonant hollow core fibers, with large core diameters and lengths of approximately 1 m, as a means to overcome such limitations. This extended light-matter interaction length principally improves the concentration detection limit by two orders of magnitude while using almost the entire sample volume-that is three orders of magnitude smaller compared to cuvette based approaches. By integrating the fibers into an optofluidic chip environment and operating within the lowest experimentally feasible transmission band, concentrations of the application-relevant pharmaceutical substances, sulfamethoxazole (SMX) and sodium salicylate (SS), were detectable down to 0.1 µM (26 ppb) and 0.4 µM (64 ppb), respectively, with the potential to reach significantly lower detection limits for further device integration.

  13. UV Absorption Spectroscopy in Water-Filled Antiresonant Hollow Core Fibers for Pharmaceutical Detection

    Directory of Open Access Journals (Sweden)

    Mona Nissen

    2018-02-01

    Full Text Available Due to a worldwide increased use of pharmaceuticals and, in particular, antibiotics, a growing number of these substance residues now contaminate natural water resources and drinking supplies. This triggers a considerable demand for low-cost, high-sensitivity methods for monitoring water quality. Since many biological substances exhibit strong and characteristic absorption features at wavelengths shorter than 300 nm, UV spectroscopy presents a suitable approach for the quantitative identification of such water-contaminating species. However, current UV spectroscopic devices often show limited light-matter interaction lengths, demand sophisticated and bulky experimental infrastructure which is not compatible with microfluidics, and leave large fractions of the sample analyte unused. Here, we introduce the concept of UV spectroscopy in liquid-filled anti-resonant hollow core fibers, with large core diameters and lengths of approximately 1 m, as a means to overcome such limitations. This extended light-matter interaction length principally improves the concentration detection limit by two orders of magnitude while using almost the entire sample volume—that is three orders of magnitude smaller compared to cuvette based approaches. By integrating the fibers into an optofluidic chip environment and operating within the lowest experimentally feasible transmission band, concentrations of the application-relevant pharmaceutical substances, sulfamethoxazole (SMX and sodium salicylate (SS, were detectable down to 0.1 µM (26 ppb and 0.4 µM (64 ppb, respectively, with the potential to reach significantly lower detection limits for further device integration.

  14. Development of Lectin-Linked Immunomagnetic Separation for the Detection of Hepatitis A Virus

    Science.gov (United States)

    Ko, Sang-Mu; Kwon, Joseph; Vaidya, Bipin; Choi, Jong Soon; Lee, Hee-Min; Oh, Myung-Joo; Bae, Hyeun-Jong; Cho, Se-Young; Oh, Kyung-Seo; Kim, Duwoon

    2014-01-01

    The accuracy and sensitivity of PCR-based methods for detection of hepatitis A virus (HAV) are dependent on the methods used to separate and concentrate the HAV from the infected cells. The pH and ionic strength affect the binding affinity of the virus to cells. In this study, we initially investigated the effects of pH (4.0–10.0) and metal ions (Fe2+, Co2+, Cu2+, Mg2+, K+, and Ca2+) on the binding of HAV to oyster digestive cells. The lowest relative binding (RB) of HAV to the cells was found at pH 4.0 and in FeSO4 solution (64.6% and 68.1%, respectively). To develop an alternative to antibody-dependent immunomagnetic separation prior to detection of HAV using RT-PCR, the binding of HAV to five lectins, peanut agglutinin (PNA), Dolichos biflorus agglutinin (DBA), Helix pomatia agglutinin (HPA), Ulex europaeus agglutinin (UEA-1) and soybean agglutinin (SBA), was evaluated using ELISAs. SBA showed significantly higher RB to HAV than the other lectins tested. In addition, HAV could be concentrated within 30 min using SBA-linked magnetic bead separation (SMS) prior to the RT-PCR assay. Our findings demonstrate the feasibility of using SMS combined with RT-PCR to detect HAV at dilutions ranging from 10−1–10−4 of a HAV stock (titer: 104 TCID50/mL). PMID:24599279

  15. Development of Lectin-Linked Immunomagnetic Separation for the Detection of Hepatitis A Virus

    Directory of Open Access Journals (Sweden)

    Sang-Mu Ko

    2014-03-01

    Full Text Available The accuracy and sensitivity of PCR-based methods for detection of hepatitis A virus (HAV are dependent on the methods used to separate and concentrate the HAV from the infected cells. The pH and ionic strength affect the binding affinity of the virus to cells. In this study, we initially investigated the effects of pH (4.0–10.0 and metal ions (Fe2+, Co2+, Cu2+, Mg2+, K+, and Ca2+ on the binding of HAV to oyster digestive cells. The lowest relative binding (RB of HAV to the cells was found at pH 4.0 and in FeSO4 solution (64.6% and 68.1%, respectively. To develop an alternative to antibody-dependent immunomagnetic separation prior to detection of HAV using RT-PCR, the binding of HAV to five lectins, peanut agglutinin (PNA, Dolichos biflorus agglutinin (DBA, Helix pomatia agglutinin (HPA, Ulex europaeus agglutinin (UEA-1 and soybean agglutinin (SBA, was evaluated using ELISAs. SBA showed significantly higher RB to HAV than the other lectins tested. In addition, HAV could be concentrated within 30 min using SBA-linked magnetic bead separation (SMS prior to the RT-PCR assay. Our findings demonstrate the feasibility of using SMS combined with RT-PCR to detect HAV at dilutions ranging from 10−1–10−4 of a HAV stock (titer: 104 TCID50/mL.

  16. Photoacoustic investigation of QCL modulation techniques

    International Nuclear Information System (INIS)

    Germer, M; Wolff, M

    2010-01-01

    High detection sensitivity and spectral selectivity is important for gas analysers to identify the measured compound and to detect low concentrations. We investigated three different modulation methods - pulse gate modulation, pulse frequency modulation and chopper modulation - for a new pulsed quantum cascade laser based photoacoustic sensor. The spectral selectivity and the detection limit for the three modulation methods are compared by measuring nitric oxide absorption lines and different concentrations. The highest detection sensitivity of 70 ppb was achieved with pulse gate modulation but at the lowest spectral resolution. The highest spectral resolution was achieved with chopper modulation but at the lowest detection sensitivity. It is demonstrated that for the three modulation methods a compromise has to be made between selectivity and sensitivity for each measuring task.

  17. Lowest-order corrections to the RPA polarizability and GW self-energy of a semiconducting wire

    NARCIS (Netherlands)

    Groot, de H.J.; Ummels, R.T.M.; Bobbert, P.A.; van Haeringen, W.

    1996-01-01

    We present the results of the addition of lowest-order vertex and self-consistency corrections to the RPA polarizability and the GW self-energy for a semiconducting wire. It is found that, when starting from a local density approximation zeroth-order Green function and systematically including these

  18. Effect of gamma irradiation on total carbohydrate concentration of finger millet flour

    International Nuclear Information System (INIS)

    Lathika; Patil, Shrikant L.; Bhasker Shenoy, K.; Somashekarappa, H.M.

    2015-01-01

    Ragi or finger millet (Eleusine coracana L.) is one of the common millets in several regions of India. The effect of gamma irradiation, on ragi flour was investigated in the study. Ragi flour is procured from market. Flour samples of 50 gms were taken in triplicates in a polyethylene pouch, air sealed and subjected to gamma irradiation doses ranging from 0.25 to 10 kGy and stored in polyethylene bags and plastic containers for a period of 30 and 90 days. Within 24 hours of irradiation, the samples were tested for total carbohydrate concentration by phenol-sulphuric acid method. The same was repeated after 30 and 90 days of storage. The comparative study showed that, at 0 day, total carbohydrate concentration has decreased slightly when compared to the non-irradiated sample (0.024 mg/ml). The lowest concentration of carbohydrate is seen at 0.025 kGy (0.019mg/ml). The samples stored in polyethylene bag, after 30 days showed both increase (0.056 mg/ml at 0.025 kGy) and decrease (0.04 mg/ml at 10 kGy) in total carbohydrate concentration when compared to control (0.046 mg/ml). 90 days stored samples showed increase in carbohydrate concentration when compared to control (0.029 mg/ml). The highest carbohydrate concentration is seen in 1 kGy dose (0.037 mg/ml). The samples stored at container after 30 days showed both increase (0.045 mg/ml at 5 kGy) and decrease (0.034 mg/ml at 0.025 mg/ml) of carbohydrate concentration when compared to control (0.043 mg/ml). 90 days stored samples showed decrease in carbohydrate concentration when compared to control (0.034 mg/ml). The lowest concentration is seen at 5 kGy (0.022 mg/ml). (author)

  19. Measurement of fluorescent probes concentration ratio in the cerebrospinal fluid for early detection of Alzheimer's disease

    Science.gov (United States)

    Harbater, Osnat; Gannot, Israel

    2014-03-01

    The pathogenic process of Alzheimer's Disease (AD), characterized by amyloid plaques and neurofibrillary tangles in the brain, begins years before the clinical diagnosis. Here, we suggest a novel method which may detect AD up to nine years earlier than current exams, minimally invasive, with minimal risk, pain and side effects. The method is based on previous reports which relate the concentrations of biomarkers in the Cerebrospinal Fluid (CSF) (Aβ and Tau proteins) to the future development of AD in mild cognitive impairment patients. Our method, which uses fluorescence measurements of the relative concentrations of the CSF biomarkers, replaces the lumbar puncture process required for CSF drawing. The process uses a miniature needle coupled trough an optical fiber to a laser source and a detector. The laser radiation excites fluorescent probes which were prior injected and bond to the CSF biomarkers. Using the ratio between the fluorescence intensities emitted from the two biomarkers, which is correlated to their concentration ratio, the patient's risk of developing AD is estimated. A theoretical model was developed and validated using Monte Carlo simulations, demonstrating the relation between fluorescence emission and biomarker concentration. The method was tested using multi-layered tissue phantoms simulating the epidural fat, the CSF in the sub-arachnoid space and the bone. These phantoms were prepared with different scattering and absorption coefficients, thicknesses and fluorescence concentrations in order to simulate variations in human anatomy and in the needle location. The theoretical and in-vitro results are compared and the method's accuracy is discussed.

  20. Paper-based microfluidic approach for surface-enhanced raman spectroscopy and highly reproducible detection of proteins beyond picomolar concentration.

    Science.gov (United States)

    Saha, Arindam; Jana, Nikhil R

    2015-01-14

    Although microfluidic approach is widely used in various point of care diagnostics, its implementation in surface enhanced Raman spectroscopy (SERS)-based detection is challenging. This is because SERS signal depends on plasmonic nanoparticle aggregation induced generation of stable electromagnetic hot spots and in currently available microfluidic platform this condition is difficult to adapt. Here we show that SERS can be adapted using simple paper based microfluidic system where both the plasmonic nanomaterials and analyte are used in mobile phase. This approach allows analyte induced controlled particle aggregation and electromagnetic hot spot generation inside the microfluidic channel with the resultant SERS signal, which is highly reproducible and sensitive. This approach has been used for reproducible detection of protein in the pico to femtomolar concentration. Presented approach is simple, rapid, and cost-effective, and requires low sample volume. Method can be extended for SERS-based detection of other biomolecules.

  1. Detection of low plasma estradiol concentrations in nesting green turtles (Chelonia mydas) by HPLC/Ms-Ms.

    Science.gov (United States)

    Mahmoud, I Y; Alkindi, A Y; Khan, T; Al-Bahry, S N

    2011-03-01

    In previous studies on nesting green turtles under natural conditions from different geographical regions, 17-β-estradiol (E(2) ) was either undetectable or detected at very low levels. RIA and other related techniques were not sensitive enough to measure low E(2) values in the green turtles. In this study, a sensitive method was used in detecting low hormone concentrations: high performance liquid chromatography with tandem quadruple mass spectrometry (HPLC-MS/MS). Using this technique, estradiol for the first time was detected in nesting green turtles during the peak season (June-October) at Ras Al-Hadd Reserve, Oman. The E(2) values recorded from this study were the highest ever recorded from nesting green turtles in any geographical region, but the levels did not vary significantly throughout different phases of nesting. The presence of E(2) during nesting presumably plays a role in the physiology and behavior of this species. Ras Al-Hadd hosts one of the largest nesting populations of green turtles in the world, and an understanding of their nesting patterns may be of value in conservation and management programs for this endangered species. Copyright © 2011 Wiley-Liss, Inc., A Wiley Company.

  2. Degeneracy of the lowest Landau level and suq(2) on the Poincare half plane

    International Nuclear Information System (INIS)

    Jellal, A.

    2000-01-01

    It is shown that the presence of the quantum group symmetry su q (2) in the quantum Hall effect on the Poincare upper half plane the degeneracy of the lowest Landau level. It is also shown that the relation between the degeneracy and the cyclic representation of su q (2) appears in accordance with q being a kth root of unity. (Authors)

  3. Detection of radon products in atmosphere and its concentration

    International Nuclear Information System (INIS)

    Al-Naemi, H.M.

    1993-01-01

    The climate of the State of Qatar is very warm during the summer and also for considerable parts of the spring and autumn. Energy-tight houses and buildings with air conditioning working day and night for several months are very common. Consequently, the problem of accumulation of indoor radon may exist. No measurements of radon concentration in Qatar have been performed before. The aim of the present work is to implement a suitable technique to measure radon concentration in Qatari houses and buildings. As a first stage, it was found reasonable to start with a technique to evaluate the short-term average indoor radon concentration. The activated charcoal method was chosen to perform this evaluation

  4. Effect of Heat-treatment on Accuracy of Infrared Spectroscopy and Digital and Optical Brix Refractometers for Measuring Immunoglobulin G Concentration in Bovine Colostrum.

    Science.gov (United States)

    Elsohaby, I; McClure, J T; Dow, N; Keefe, G P

    2018-01-01

    Heat-treatment of colostrum is a method developed to reduce calf exposure to pathogens. Infrared (IR) spectroscopy and Brix refractometers can be used for measuring colostral IgG concentration and assessing colostrum quality. To determine the impact of heat-treatment on accuracy of IR spectroscopy and Brix refractometers for measuring colostral IgG concentration and assessing colostrum quality before and after heat-treatment. A total of 60 Holstein dairy cows on 8 commercial dairy farms. A cross-sectional study was designed to determine the effect of heat-treatment at 60°C and 63°C each for 30 and 60 minutes duration on colostral IgG concentration measured by the reference radial immunodiffusion (RID) assay, IR spectroscopy, and digital and optical refractometers. Colostrum IgG concentration significantly decreased after heat-treatment at 63°C for 30 or 60 minutes as measured by RID, but the IgG values remained unchanged when measured by IR spectroscopy and refractometers. The lowest correlation coefficient found between IR spectroscopy (r = 0.70) and RID results was in colostrum heat-treated at 63°C for 60 minutes. For digital (r = 0.48) and optical (r = 0.50) refractometers, the lowest correlation coefficient was at 63°C for 30 minutes when compared to RID. The accuracy of the IR spectroscopy, digital and optical Brix refractometers was decreased from 91.7 to 80%, 81.7 to 45%, and 80 to 45%, respectively, when colostrum heat-treated at 63°C for 60 minutes. Radial immunodiffusion, IR spectroscopy, and Brix refractometers exhibit utility for measuring IgG concentration when colostrum heat-treated at 60°C but does not detect decrease IgG concentrations when heat-treated at 63°C. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Charge-Transfer Dynamics in the Lowest Excited State of a Pentacene–Fullerene Complex: Implications for Organic Solar Cells

    KAUST Repository

    Joseph, Saju

    2017-10-02

    We characterize the dynamic nature of the lowest excited state in a pentacene/C60 complex on the femtosecond time scale, via a combination of ab initio molecular dynamics and time-dependent density functional theory. We analyze the correlations between the molecular vibrations of the complex and the oscillations in the electron-transfer character of its lowest excited state, which point to vibration-induced coherences between the (pentacene-based) local-excitation (LE) state and the complex charge-transfer (CT) state. We discuss the implications of our results on this model system for the exciton-dissociation process in organic solar cells.

  6. Changes in Rice Pesticide Use and Surface Water Concentrations in the Sacramento River Watershed, California

    Science.gov (United States)

    Orlando, James L.; Kuivila, Kathryn

    2004-01-01

    in the basin area feeding the Colusa Basin Drain 1, is consistent with the higher use ratio, suggesting that differences in application amounts can explain the observed concentration differences. The samples from the downstream site (Tower) sampled in 2002 had the lowest concentrations of pesticides. Performance goals were exceeded for either molinate or thiobencarb in six samples from the upstream sites, but not in any samples from the downstream Tower site. In 2003, concentrations at upstream sites were much lower than the previous year with only one sample containing thiobencarb at a concentration above the performance goal. Lower concentrations could be partially due to delays in rice planting and pesticide application owing to spring rainstorms. Historical data is available on peak concentrations of molinate and thiobencarb measured at Colusa Basin Drain 5 (one of our sites in 2003) since 1981. Implementing holding times for pesticide-treated rice field water in the early 1980s succeeded in decreasing concentrations in surface waters. Detailed pesticide use data is available since 1991 and changing use patterns for molinate and thiobencarb can explain some, but not all, of the trends in peak pesticide concentrations. A stronger relationship is seen between the lengths of time that performance goals were exceeded and the amount of a pesticide applied within a basin. Different extraction and analytical techniques were used to improve the recovery and lower the method detection limit for lambda-cyhalothrin. Recoveries of lambda-cyhalothrin from solid-phase extraction cartridges typically vary, so subsamples were processed by liquid-liquid extraction. The advantage of using a larger sample volume (3 L instead of 1 L) to lower detection limits was offset by poor recovery during the cleanup step using an activated carbon column. Results suggest that as the concentrations of dissolved organic carbon in the sample increase, the recovery g

  7. Sandwich-type enzyme immunoassay for big endothelin-I in plasma: concentrations in healthy human subjects unaffected by sex or posture.

    Science.gov (United States)

    Aubin, P; Le Brun, G; Moldovan, F; Villette, J M; Créminon, C; Dumas, J; Homyrda, L; Soliman, H; Azizi, M; Fiet, J

    1997-01-01

    A sandwich-type enzyme immunoassay has been developed for measuring human big endothelin-1 (big ET-1) in human plasma and supernatant fluids from human cell cultures. Big ET-1 is the precursor of endothelin 1 (ET-1), the most potent vasoconstrictor known. A rabbit antibody raised against the big ET-1 COOH-terminus fragment was used as an immobilized antibody (anti-P16). The Fab' fragment of a monoclonal antibody (1B3) raised against the ET-1 loop fragment was used as the enzyme-labeled antibody, after being coupled to acetylcholinesterase. The lowest detectable value in the assay was 1.2 pg/mL (0.12 pg/well). The assay was highly specific for big ET-1, demonstrating no cross-reactivity with ET-1, big endothelin-2 (big ET-2), and big endothelin-3 (big ET-3). We used this assay to evaluate the effect of two different postural positions (supine and standing) on plasma big ET-1 concentrations in 11 male and 11 female healthy subjects. Data analysis revealed that neither sex nor body position influenced plasma big ET-1 concentrations. This assay should thus permit the detection of possible variations in plasma concentrations of big ET-1 in certain pathologies and, in association with ET-1 assay, make possible in vitro study of endothelin-converting enzyme activity in cell models. Such studies could clarify the physiological and clinical roles of this family of peptides.

  8. Consumer Airfare Report: Table 5 - Detailed Fare Information For Highest and Lowest Fare Markets Under 750 Miles

    Data.gov (United States)

    Department of Transportation — Provides detailed fare information for highest and lowest fare markets under 750 miles. For a more complete explanation, please read the introductory information at...

  9. Excitation energy of the lowest 2+ and 3- levels in 32Mg and 146Gd

    International Nuclear Information System (INIS)

    Barranco, M.; Lombard, R.J.

    1978-06-01

    The excitation energy of the lowest 2 + and 3 - levels are calculated for neutron rich Mg-isotopes as well as for N=82 isotones. The calculations are made by assuming quadrupole-quadrupole and octupole-octupole forces. The quasi-particles energies and occupation numbers are taken from the energy density method

  10. How Effective Are Community College Remedial Math Courses for Students with the Lowest Math Skills?

    Science.gov (United States)

    Xu, Di; Dadgar, Mina

    2018-01-01

    Objective: This article examines the effectiveness of remediation for community college students who are identified as having the lowest skills in math. Method: We use transcript data from a state community college system and take advantage of a regression discontinuity design that compares statistically identical students who are assigned to the…

  11. Distribution of 210Pb and 210Po concentrations in wild berries and mushrooms in boreal forest ecosystems

    International Nuclear Information System (INIS)

    Vaaramaa, Kaisa; Solatie, Dina; Aro, Lasse

    2009-01-01

    The activity concentrations and distribution of 210 Pb and 210 Po in wild berries and edible mushrooms were investigated in Finnish forests. The main study areas were located in Scots pine (Pinus sylvestris L.) forests in southern and northern Finland. The activity concentrations of 210 Pb and 210 Po in blueberry (Vaccinium myrtillus L.) and lingonberry (Vaccinium vitis-idaea L.) samples decreased in the order: stems > leaves > berries (i.e. fruits). The activity ratios of 210 Po/ 210 Pb in the wild berry samples were mainly higher than one, indicating elevated activity concentrations of polonium in the samples. In mushrooms the activity concentrations of 210 Pb and especially 210 Po were higher than in fruits of the wild berries. The highest activity concentration of 210 Pb was detected in Cortinarius armillatus L. (16.2 Bq kg -1 d.w.) and the lowest in Leccinum vulpinum L. (1.38 Bq kg -1 d.w.). The 210 Po activity concentrations of the whole fruiting bodies ranged from 7.14 Bq kg -1 d.w. (Russula paludosa L.) to 1174 Bq kg -1 d.w. (L. vulpinum L.). In general, the highest activity concentrations of 210 Po were recorded in boletes. The caps of mushrooms of the Boletaceae family showed higher activity concentrations of 210 Po compared to the stipes. In most of the mushrooms analyzed, the activity concentrations of 210 Po were higher than those of 210 Pb. 210 Po and 210 Pb dominate the radiation doses received via ingestion of wild berries and mushrooms in northern Finland, while in southern Finland the ingested dose is dominated by 137 Cs from the Chernobyl fallout.

  12. Feasibility for EGRET detection of antimatter concentrations in the universe

    Science.gov (United States)

    Hartman, R. C.

    1990-01-01

    Although the Grand Unified Theories of elementary particle dynamics have to some extent reduced the aesthetic attraction of matter-antimatter symmetry in the Universe, the idea is still not ruled out. Although first introduced by Alfven (1965), most of the theoretical development related to gamma-ray astronomy was carried out by Stecker, who has proposed (Stecker, Morgan, and Bredekamp, 1971) matter-antimatter annihilation extending back to large redshifts as a possible explanation of the apparently extragalactic diffuse gamma radiation. Other candidate explanations were also proposed, such as superposition of extragalactic discrete sources. Clearly, the existence of significant amounts of antimatter in the universe would be of great cosmological importance; its detection, however, is not simple. Since the photon is its own antiparticle, it carries no signature identifying whether it originated in a matter or an antimatter process; even aggregates of photons (spectra) are expected to be identical from matter and antimatter processes. The only likely indicator of the presence of concentrations of antimatter is evidence of its annihilation with normal matter, assuming there is some region of contact or overlap. The EGRET (Energetic Gamma-Ray Experimental Telescope) on the Gamma Ray Observatory, with a substantial increase in sensitivity compared with earlier high energy gamma ray telescopes, may be able to address this issue. The feasibility of using EGRET in such a search for antimatter annihilation in the Universe is considered.

  13. Feasibility for EGRET detection of antimatter concentrations in the universe

    International Nuclear Information System (INIS)

    Hartman, R.C.

    1990-01-01

    Although the Grand Unified Theories of elementary particle dynamics have to some extent reduced the aesthetic attraction of matter-antimatter symmetry in the Universe, the idea is still not ruled out. Although first introduced by Alfven (1965), most of the theoretical development related to gamma-ray astronomy was carried out by Stecker, who has proposed (Stecker, Morgan, and Bredekamp, 1971) matter-antimatter annihilation extending back to large redshifts as a possible explanation of the apparently extragalactic diffuse gamma radiation. Other candidate explanations were also proposed, such as superposition of extragalactic discrete sources. Clearly, the existence of significant amounts of antimatter in the universe would be of great cosmological importance; its detection, however, is not simple. Since the photon is its own antiparticle, it carries no signature identifying whether it originated in a matter or an antimatter process; even aggregates of photons (spectra) are expected to be identical from matter and antimatter processes. The only likely indicator of the presence of concentrations of antimatter is evidence of its annihilation with normal matter, assuming there is some region of contact or overlap. The EGRET (Energetic Gamma-Ray Experimental Telescope) on the Gamma Ray Observatory, with a substantial increase in sensitivity compared with earlier high energy gamma ray telescopes, may be able to address this issue. The feasibility of using EGRET in such a search for antimatter annihilation in the Universe is considered

  14. Effect of alternative salt use on broiler breast meat yields, tenderness, flavor, and sodium concentration.

    Science.gov (United States)

    Broadway, P R; Behrends, J M; Schilling, M W

    2011-12-01

    Fresh chicken breast fillets were marinated with gourmet-style salts: Himalayan pink salt, Sonoma gourmet salt, sel gus de Guerande, and Bolivian rose salt to evaluate their effects on marination and cook loss yields, tenderness, sensory attributes, and sodium concentration. Fresh chicken breast fillets (48-h postmortem) were vacuum tumbled (137 kPa at 20 rpm for 17 min) in a solution of water, salt, and sodium tripolyphosphate at a level of 20% of the meat weights. Instrumental analyses showed no significant difference (P > 0.05) in meat quality with respect to marination yield, cook yield, or shear-force value. There were also no significant differences (P > 0.05) in sensory descriptors between salt treatments. However, Sonoma gourmet salt showed a tendency (P = 0.0693) to score increased savory note values from panelists, whereas Bolivian rose salt received the lowest score. There were no significant differences (P > 0.05) in sodium concentrations between salt treatments, but numerically, sel gus de Guerande had the lowest sodium concentration, which could be important in producing reduced sodium products. Understanding different salts and sodium concentrations allows the poultry industry to use gourmet salts in products and maintain overall meat quality and flavor.

  15. Concentration of 232Th, 230Th and 228Th in various tissues of Japanese subjects

    International Nuclear Information System (INIS)

    Takizawa, Y.; Qingmei, H.; Hisamatsu, S.; Abe, T.

    1997-01-01

    The concentration of 232 Th, 230 Th and 228 Th in various human tissues of Japanese subjects obtained at autopsies are reported. The tissue samples were weighed, spiked with 234 Th tracer and ashed by acid. The solution was dried on a hot-plate. Separation of thorium radionuclides was accomplished through cation-exchange resin chromatography and electrodeposition. The concentrations of thorium isotopes were measured by α-spectrometry. Thorium-232 and 230 Th concentrations were found to be highest in lung, followed by bone. The maximum concentration of 228 Th was in bone. The lowest concentrations of thorium isotopes were in muscle. (author)

  16. Serum copper and zinc concentrations in a representative sample of the Canarian population.

    Science.gov (United States)

    Díaz Romero, Carlos; Henríquez Sánchez, Patricia; López Blanco, Félix; Rodríguez Rodríguez, Elena; Serra Majem, Lluis

    2002-01-01

    Serum copper (Cu) and zinc (Zn) concentrations of 395 individuals (187 males + 208 females) living in Canary Islands were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 1.10 +/- 0.25 mg/L and 1.16 +/- 0.52 mg/L respectively. Our data were similar to other data published in other Spanish regions. Individuals from Lanzarote presented a mean Cu and Zn concentrations higher (p EL Hierro showed the lowest (p 0.05) among the different age intervals. No clear trends in the serum Cu and Zn concentrations were observed when drinking and smoking habits were considered. The increase of physical exercise reduced (p < 0.05) the serum Cu concentrations.

  17. Effect of ventilation type on radon concentration at places of work

    International Nuclear Information System (INIS)

    Oksanen, E.

    1994-01-01

    Indoor radon ( 222 Rn) concentrations were measured at 76 child care facilities and 36 schools in southern Finland. The buildings had three different types of ventilation systems: mechanical air supply and exhaust, mechanical exhaust, and natural ventilation, the first being most common. The effect of the ventilation type on the long-term radon concentration was studied in child care facilities. The radon concentrations were highest in the naturally ventilated buildings. The mechanical air supply and exhaust system maintained the lowest values in cold wintertime. In school buildings both the long-term radon concentration and short-term radon and daughter concentrations were measured. The correlation of the ventilation type and the radon concentration was not obvious in this group of measurements, but the radon concentrations and the equilibrium factors were highest in buildings with natural ventilation. Radon concentrations were generally lower during the working hours than during the one-month period, as expected. (author)

  18. Measurements of 212Pb concentration in the ground-level air in Beijing area and assessment of ionizing radiation exposure of the population

    International Nuclear Information System (INIS)

    Lin Lianqing; Wen Huifen; Zhou Yuanwen

    1994-01-01

    The paper describes the method of measuring 212 Pb concentration in the ground-level air with a gamma spectrometer and the results of the measurements of 212 Pb concentrations during February 1988-January 1989. The results showed that the average and standard deviation are 0.54 and 0.40 Bq·m -3 ; the distribution of 212 Pb concentrations in air was logarithmic normal distribution, geometric average and geometric standard deviation are 0.44 Bq·m -3 and 2.0. The 212 Pb concentration in rain season is the lowest (0.42 Bq·m -3 ) while in heating season is the highest (0.66 Bq· -3 ). In period of a day, 212 Pb concentration in the morning 0-4 o'clock is the highest and in the afternoon 12-18 o'clock is the lowest, 212 Pb(max)/ 212 Pb(min) = 4.8

  19. Study on the effects of different cooking methods on concentration of essential elements (Fe, Zn, Cu, Ni in Cyprinus Carpio

    Directory of Open Access Journals (Sweden)

    Askary Sary A., Askary Sary A.,

    2017-11-01

    Full Text Available This study was performed to evaluate the effect of different cooking methods on the level of iron, copper, zinc, and nickel in the muscle of Cyprinus carpio. For this purpose, 75 samples of fish with different sizes were obtained from Azadegan Aquaculture Center in Ahvaz. The samples were digested through the wet-digestion method and the concentrations of the essential elements were measured by Atomic Absorption Spectrophotometer. According to the results, fried and steamed samples had the highest (3.54±0.31 mg/100g wet weight and lowest (1.64±0.11 mg/100g wet weight concentration of iron. The highest and lowest concentration of zinc was recorded in the fried (1.74±0.09 mg/100g WW and steamed (1.24±0.09 mg/100g WW samples, respectively. In the case of copper, the highest (0.12±0.09 mg/100g WW and lowest (0.07±0.003 mg/100g WW concentration were recorded in the micro-waved and steamed specimens, respectively. The results for nickel was determined as 0.023±0.001 mg/100g WW and 0.016±0.0002 mg/100g WW in the fried and grilled fishes Moreover, the highest and the lowest level of essential elements which were recorded among the samples belonged to iron and nickel respectively. In all samples, the level of iron was recorded below the FDA limit. In addition, in all samples, the level of nickel, zinc, and copper was estimated below the maximum acceptable limit of WHO, MAFF, NHMRC, and FAO.

  20. Distribution of Mercury Concentrations in Tree Rings and Surface Soils Adjacent to a Phosphate Fertilizer Plant in Southern Korea.

    Science.gov (United States)

    Jung, Raae; Ahn, Young Sang

    2017-08-01

    This study aimed to determine mercury concentrations in tree rings and surface soils at distances of 4, 26 and 40 km from a fertilizer plant located in Yeosu City, Korea. Mercury concentrations in all tree rings were low prior to the establishment of the plant in 1977 and became elevated thereafter. The highest average mercury concentration in the tree rings was 11.96 ng g -1 at the Yeosu site located nearest to the plant, with the lowest average mercury concentration of 4.45 ng g -1 at the Suncheon site furthest away from the plant. In addition, the highest mercury content in the surface soil was 108.51 ng cm -3 at the Yeosu site, whereas the lowest mercury content in the surface soil was 31.47 ng cm -3 at the Suncheon site. The mercury levels decreased gradually with increasing distance from the plant.

  1. Sleep Duration Associated with the Lowest Risk of Depression/Anxiety in Adolescents.

    Science.gov (United States)

    Ojio, Yasutaka; Nishida, Atsushi; Shimodera, Shinji; Togo, Fumiharu; Sasaki, Tsukasa

    2016-08-01

    To investigate sleep duration associated with the least depression/anxiety in adolescence. Grades 7-12 Japanese students (n = 18,250, aged 12-18 y) from public junior high/high schools were studied in a cross-sectional design. Due to missing/implausible data, 15,637 out of the 18,250 students were statistically analyzed. Relationship between sleep duration on school nights and depression/anxiety, measured using self-report questionnaires, including the General Health Questionnaire-12 (GHQ-12), were studied by sex and grade, controlling for bedtime regularity. When sleep duration was classified by 1-h intervals, rate of adolescents with a GHQ-12 score ≥ 4 was the lowest in males and females who slept 8.5-9.5 h and 7.5-8.5 h, respectively, (designated "references") in both grades 7-9 and 10-12. The rate was significantly higher than the references in both males and females who slept Sleep duration for the minimum GHQ-12 score was estimated to be 8.8 and 8.5 h in males, and 8.0 and 7.5 h in females, in grades 7-9 and 10-12, respectively, using the General Additive Model. Sleep duration of ≥ 8.5 h on school nights may be associated with the lowest risk of depression/anxiety on average in male adolescents. Although the duration was estimated to be shorter in females (≥ 7.5 h) than males, this should be interpreted carefully. Most adolescents may currently be sleeping less than the optimal duration. A commentary on this article appears in this issue on page 1491. © 2016 Associated Professional Sleep Societies, LLC.

  2. THE LOWEST-MASS MEMBER OF THE β PICTORIS MOVING GROUP

    International Nuclear Information System (INIS)

    Rice, Emily L.; Faherty, Jacqueline K.; Cruz, Kelle L.

    2010-01-01

    We present spectral and kinematic evidence that 2MASS J06085283-2753583 (M8.5γ) is a member of the β Pictoris Moving Group (BPMG, age ∼12 Myr), making it the latest-type known member of this young, nearby association. We confirm low-gravity spectral morphology at both medium and high resolutions in the near-infrared. We present new radial velocity and proper motion measurements, and use these to calculate galactic location and space motion consistent with other high-probability members of the BPMG. The predicted mass range consistent with the object's effective temperature, surface gravity, spectral type, and age is 15-35 M Jup , placing 2MASS 0608-27 well within the brown dwarf mass regime. 2MASS J06085283-2753583 is thus confidently added to the short list of very low mass, intermediate age benchmark objects that inform ongoing searches for the lowest-mass members of nearby young associations.

  3. Time-resolved resonance raman spectrum of all-trans-diphenylbutadiene in the lowest excited singlet state

    DEFF Research Database (Denmark)

    Wilbrandt, Robert Walter; Jensen, Niels-Henrik; Langkilde, F.W.

    1984-01-01

    The resonance Raman spectrwn of all-trans-diphenylbutadiene in its lowest excited S1 state excited in resonance with the S1 → Sn absorption band at 650 nm in non-polar solvents is reported. Three vibrational bands at 1572, 1481 and 1165 cm−1 are observed. A possible assignment of the the 1481 cm−...

  4. Concentration of radionuclides in uranium tailings and its uptake by plants at Jaduguda, Jharkhand, India

    International Nuclear Information System (INIS)

    Singh, Lal; Soni, Prafulla

    2010-01-01

    Mining and processing of uranium ore was started in several parts of eastern Singhbhum, viz. Jaduguda, Bhatin and Narwapahar (Jharkhand) in 1968. Radioactivity in the mine tailings has to be consolidated so that it does not emanate in the atmosphere or enter the food chain. Hence, the area has been covered with 30 cm thick soil cover followed by development of plant species that do not have any socioeconomic relevance in the area. Seven native plant species of forestry origin, viz. Colebrookea oppositifolia, Dodonaea viscosa, Furcraea foetida, Imperata cylindrica, Jatropha gossypifolia, Pogostemon benghalense and Saccharum spontaneum have been selected for experimental trials. Distribution and concentration of radionuclides have been evaluated in a tailing pond at different depths in soil and tailings. Radionuclide uptake in each of the selected plant species has been evaluated and discussed in this article. The highest concentration of radionuclides has been found in tailings > soil cover on tailings > roots of selected plant species > shoots of all the selected species. These results show that among the seven species tried, J. gossypifolia and F. foetida have the lowest uptake (below detectable limits), while S. spontaneum and P. benghalense have comparatively higher uptake. However, radionuclide concentration in all the tried species is significantly low compared to species of natural occurrence which have higher radionuclides uptake and accumulation. (author)

  5. Concentration of radionuclides in uranium tailings and its uptake by plants at Jaduguda, Jharkhand, India

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Lal; Soni, Prafulla [Ecology and Environment Div., Forest Research Institute, Dehradun (India)

    2010-01-10

    Mining and processing of uranium ore was started in several parts of eastern Singhbhum, viz. Jaduguda, Bhatin and Narwapahar (Jharkhand) in 1968. Radioactivity in the mine tailings has to be consolidated so that it does not emanate in the atmosphere or enter the food chain. Hence, the area has been covered with 30 cm thick soil cover followed by development of plant species that do not have any socioeconomic relevance in the area. Seven native plant species of forestry origin, viz. Colebrookea oppositifolia, Dodonaea viscosa, Furcraea foetida, Imperata cylindrica, Jatropha gossypifolia, Pogostemon benghalense and Saccharum spontaneum have been selected for experimental trials. Distribution and concentration of radionuclides have been evaluated in a tailing pond at different depths in soil and tailings. Radionuclide uptake in each of the selected plant species has been evaluated and discussed in this article. The highest concentration of radionuclides has been found in tailings > soil cover on tailings > roots of selected plant species > shoots of all the selected species. These results show that among the seven species tried, J. gossypifolia and F. foetida have the lowest uptake (below detectable limits), while S. spontaneum and P. benghalense have comparatively higher uptake. However, radionuclide concentration in all the tried species is significantly low compared to species of natural occurrence which have higher radionuclides uptake and accumulation. (author)

  6. Portable monitors for measuring radon and its progenies air by intergrated sampling method

    International Nuclear Information System (INIS)

    Zhang Huaiqin; Su Jingling; Yao Wanyuan; Liu Jinhua

    1989-01-01

    Two kinds of portable monitors have been developed, which can be used to measure the concentration of radon or potential energy concentration of radon or potential energy concentration of radon progenies in air. The thermoluminescent material CaSO 4 (Tm) is used as a detecting element for both of them. The lowest detectable limit of the passive radon monitor is about 1.5 Bq/m 3 for radon in air, as the exposure time being one week. Its main advantages are high reliability and convenient manipulation. The working level monitor for radon progenies in air consists of a mini membrane pump and an integrating probe. The lowest detectable limit is about 6.2 x 10 -9 J/m 3 , as the sampling time being 6 hours. It weights only about 0.35 kg

  7. Impurity binding energy of lowest-excited state in (In,Ga)N–GaN spherical QD under electric field effect

    International Nuclear Information System (INIS)

    Ghazi, Haddou El; Jorio, Anouar; Zorkani, Izeddine

    2013-01-01

    External electric field effect on the lowest-excited state in wurtzite (In,Ga)N–GaN spherical quantum dot is considered. By means of a traditional Ritz variational method within the effective-mass approximation and finite potential barrier, the lowest-excited state energy with and without the presence of the impurity is investigated. The normalized binding energy under electric field effect is also performed. Our numerical results are compared with the previous theoretical findings and show a good agreement with those concerning especially the ground-state for different semiconductors materials and different QDs-shapes

  8. Impurity binding energy of lowest-excited state in (In,Ga)N–GaN spherical QD under electric field effect

    Energy Technology Data Exchange (ETDEWEB)

    Ghazi, Haddou El, E-mail: hadghazi@gmail.com [LPS, Faculty of Sciences, Dhar EL Mehrez, B.P 1796 Atlas, Fez (Morocco); Special Mathematics, CPGE Kénitra (Morocco); Jorio, Anouar; Zorkani, Izeddine [LPS, Faculty of Sciences, Dhar EL Mehrez, B.P 1796 Atlas, Fez (Morocco)

    2013-10-01

    External electric field effect on the lowest-excited state in wurtzite (In,Ga)N–GaN spherical quantum dot is considered. By means of a traditional Ritz variational method within the effective-mass approximation and finite potential barrier, the lowest-excited state energy with and without the presence of the impurity is investigated. The normalized binding energy under electric field effect is also performed. Our numerical results are compared with the previous theoretical findings and show a good agreement with those concerning especially the ground-state for different semiconductors materials and different QDs-shapes.

  9. Detection of somaclonal variation by random amplified polymorphic ...

    African Journals Online (AJOL)

    Detection of somaclonal variation by random amplified polymorphic DNA analysis during micropropagation of Phalaenopsis bellina (Rchb.f.) Christenson. ... Among the primers used, P 16 produced the highest number of bands (29), while primer OPU 10 produced the lowest number (15). The range of similarity coefficient ...

  10. 226Ra concentrations in crayfish tissues, water, and sediments from the Serpent River Basin in Northeastern Ontario, Canada

    International Nuclear Information System (INIS)

    Alikhan, M.A.

    1996-01-01

    Lower Serpent River, as well as Elliot, McCarthy and McCabe lakes had highest 226 Ra contamination, Chrisman, Quirke and Whiskey lakes a moderate one, Flack and Semiwhite lakes and the 'distant' control, Lake Wanapitei, the lowest. 226 Ra activity in Cambarus robustus tissues was directly related to their background levels. Thus, concentration coefficient (tissue/sediment concentrations) for 226 Ra ranged from 0.53 to 0.74 in highly contaminated Elliot and McCarthy lakes, 0.28 to 0.59 in moderately contaminated Quirke and Whiskey lakes, and from 0.27 to 3.44 in least contaminated Semiwhite and Flack lakes. Among various organs analysed, exoskeleton showed the highest (43.04 - 90.69%) and the tail muscles the lowest (2.95 -17.14%) 226 Ra activity. 226 Ra concentrations in the alimentary canal were considered a part of the ambient environment as they had not been absorbed

  11. Sit still and pay attention: Using the Wii Balance-Board to detect lapses in concentration in children during psychophysical testing.

    Science.gov (United States)

    Jones, Pete R

    2018-05-16

    During psychophysical testing, a loss of concentration can cause observers to answer incorrectly, even when the stimulus is clearly perceptible. Such lapses limit the accuracy and speed of many psychophysical measurements. This study evaluates an automated technique for detecting lapses based on body movement (postural instability). Thirty-five children (8-11 years of age) and 34 adults performed a typical psychophysical task (orientation discrimination) while seated on a Wii Fit Balance Board: a gaming device that measures center of pressure (CoP). Incorrect responses on suprathreshold catch trials provided the "reference standard" measure of when lapses in concentration occurred. Children exhibited significantly greater variability in CoP on lapse trials, indicating that postural instability provides a feasible, real-time index of concentration. Limitations and potential applications of this method are discussed.

  12. The colorimetric detection of Pb2+ by using sodium thiosulfate and hexadecyl trimethyl ammonium bromide modified gold nanoparticles.

    Science.gov (United States)

    Zhang, Yujie; Leng, Yumin; Miao, Lijing; Xin, Junwei; Wu, Aiguo

    2013-04-21

    A simple, rapid colorimetric detection method for Pb(2+) in aqueous solution has been developed by using sodium thiosulfate (Na2S2O3) and hexadecyl trimethyl ammonium bromide (CTAB) modified gold nanoparticles (Au NPs). Na2S2O3 was added into the Au NP solution and thiosulfate ions (S2O3(2-)) were adsorbed on the surface of the Au NPs due to electrostatic interactions. Au atoms on the surface of the Au NPs were then oxidized to Au(i) by the O2 that existed in the solution in presence of thiosulfate. The addition of Pb(2+) (the final concentration was lower than 10 μM), accelerated the leaching of the Au NPs, and Pb-Au alloys also formed on the surface of the Au NPs. There was an obvious decrease in the surface plasmon resonance (SPR) absorption of the Au NPs. The lowest concentration for Pb(2+) that could be detected by the naked eye was 0.1 μM and using UV-vis spectroscopy was 40 nM. This is lower than the lead toxic level defined by the US Environmental Protection Agency (US EPA), which is 75 nM. In this method, CTAB, as a stabilizing agent for Au NPs, can accelerate the adsorption of S2O3(2-) on the surface of the Au NPs, which shortened the detection time to within 30 min. Moreover, this detection method is simple, cheap and environmentally friendly.

  13. Uncertainty of Blood Alcohol Concentration (BAC Results as Related to Instrumental Conditions: Optimization and Robustness of BAC Analysis Headspace Parameters

    Directory of Open Access Journals (Sweden)

    Haleigh A. Boswell

    2015-12-01

    Full Text Available Analysis of blood alcohol concentration is a routine analysis performed in many forensic laboratories. This analysis commonly utilizes static headspace sampling, followed by gas chromatography combined with flame ionization detection (GC-FID. Studies have shown several “optimal” methods for instrumental operating conditions, which are intended to yield accurate and precise data. Given that different instruments, sampling methods, application specific columns and parameters are often utilized, it is much less common to find information on the robustness of these reported conditions. A major problem can arise when these “optimal” conditions may not also be robust, thus producing data with higher than desired uncertainty or potentially inaccurate results. The goal of this research was to incorporate the principles of quality by design (QBD in the adjustment and determination of BAC (blood alcohol concentration instrumental headspace parameters, thereby ensuring that minor instrumental variations, which occur as a matter of normal work, do not appreciably affect the final results of this analysis. This study discusses both the QBD principles as well as the results of the experiments, which allow for determination of more favorable instrumental headspace conditions. Additionally, method detection limits will also be reported in order to determine a reporting threshold and the degree of uncertainty at the common threshold value of 0.08 g/dL. Furthermore, the comparison of two internal standards, n-propanol and t-butanol, will be investigated. The study showed that an altered parameter of 85 °C headspace oven temperature and 15 psi headspace vial pressurization produces the lowest percent relative standard deviation of 1.3% when t-butanol is implemented as an internal standard, at least for one very common platform. The study also showed that an altered parameter of 100 °C headspace oven temperature and 15-psi headspace vial pressurization

  14. Study of Fe, Zn, Cu, Cd, Pb concentrations in liver, kidney and muscle tissue of cow and sheep marketed in Hamedan in 2011

    Directory of Open Access Journals (Sweden)

    S Sobhanardakani

    2012-11-01

    Full Text Available Importance of heavy metals in food safety and detrimental effects of their high concentrations in food stuff is well documented. In this study, concentrations of Fe, Zn, Cu, Cd and Pb in kidney, liver and muscle tissues of cow and sheep at Hamedan retails were evaluated. A total number of 180 samples was assessed for the amount of heavy metals as ppb in wet weight. For this, wet-digestion method was used to determine the concentration of given elements by ICP (Varian ES-710. Results showed that the highest concentration of heavy metals was determined in the liver and kidney samples, while the lowest concentration was found in muscle tissue. Among the heavy metals, Fe in cow’s liver had the highest concentration (25507±879 ppb and Cd in muscle tissue of sheep has the lowest concentration (192±54 ppb. In overall, accumulation of heavy metals in tissues of cows was higher than sheep. Statistical comparison of accumulated metals concentration in various tissues of these two animal groups showed significant difference (P

  15. Lowest excited-state impurity binding energy in InGaN/GaN parabolic QWW: magnetic field effect

    International Nuclear Information System (INIS)

    Haddou El Ghazi; Anouar Jorio; Izeddine Zorkani

    2013-01-01

    In this paper, we have investigated the magnetic field effect on the lowest excited-state binding energy of hydrogenic shallow-donor impurity in wurtzite (In,Ga)N/GaN parabolic transversal-section quantum-well wire (PQWW) using the finite-difference method within the quasi-one-dimensional effective potential model. The calculations are performed within the framework of the effective mass approximation. A cylindrical QWW effective radius is taken into account to describe the lateral confinement strength. The numerical results show that: (i) the probability density is the largest on a circularity whose radius is the effective radius and (ii) the lowest excited-state binding energy is the largest when an impurity is located on this circularity while it starts to decrease as the impurity is away from the circularity. (author)

  16. Plasma homocyst(e)ine concentrations in eclamptic and preeclamptic African women postpartum.

    Science.gov (United States)

    Rajkovic, A; Mahomed, K; Malinow, M R; Sorenson, T K; Woelk, G B; Williams, M A

    1999-09-01

    To examine the relationship between plasma homocyst(e)ine and risk of eclampsia and preeclampsia among sub-Saharan African women who delivered at Harare Maternity Hospital in Zimbabwe. We ran a hospital-based, case-control study at Harare Maternity Hospital, University of Zimbabwe, Harare, Zimbabwe comprising 33 pregnant women with eclampsia and 138 with preeclampsia. Controls were 185 normotensive pregnant women. Plasma was collected postpartum and homocyst(e)ine levels were measured by high-performance liquid chromatography and electrochemical detection. Women with eclampsia or preeclampsia had significantly higher mean homocyst(e)ine levels than normotensive controls (12.54 or 12.77 micromol/L versus 9.93 micromol/L, respectively, Pine distribution (median 13.9 micromol/L) compared with women in the lowest quartile (median 6.2 micromol/L). The corresponding OR for preeclampsia was 4.57. Nulliparas with elevated homocyst(e)ine had a 12.90 times higher risk of preeclampsia compared with multiparas without elevated homocyst(e)ine. Postpartum plasma homocyst(e)ine concentrations are higher among Zimbabwean women with eclampsia and preeclampsia compared with normotensive women.

  17. Effects of different concentrations of pollen extract on brain tissues of Oncorhynchus mykiss

    Directory of Open Access Journals (Sweden)

    Mehmet Fuat Gulhan

    2014-03-01

    Full Text Available Objective: To determine the antioxidant capacities of pollen extract applied at different concentrations on biochemical parameters in brain tissues of rainbow trouts. Methods: The effective concentration of pollen was determined with some biochemical parameters in brain tissues of fish treated at various concentrations of the pollen extract (0.5, 2.5, 5, 10, 20 and 30 mg/L for 96 h. The malondialdehyde levels, total antioxidant status, total oxidant status, oxidative stress index and amounts of total free sulfhydryl groups were analyzed in fish brain. Results: The malondialdehyde levels decreased in groups of 0.5, 2.5, 5, 10, 20 and 30 mg/L pollen-treated compared to control group (P<0.05. The highest level of total antioxidant status (P<0.05 and the lowest value (P<0.05 of the total oxidant status was 10 mg/L concentration of pollen. Oxidative stress index and level of sulfhydryl groups showed lowest values (P<0.05 in 10 mg/L pollen treated group compared with control group. Conclusions: To apply the pollen to fish reduces the detrimental effects and modulates oxidative status via activating antioxidant defense systems at brain tissue. As a result, pollen can be added up to 10 mg/L to the medium of rainbow trout to improve health of fish.

  18. Three different signal amplification strategies for the impedimetric sandwich detection of thrombin

    Energy Technology Data Exchange (ETDEWEB)

    Ocaña, Cristina; Valle, Manel del, E-mail: manel.delvalle@uab.cat

    2016-03-17

    In this work, we report a comparative study on three highly specific amplification strategies for the ultrasensitive detection of thrombin with the use of aptamer sandwich protocol. The protocol consisted on the use of a first thrombin aptamer immobilized on the electrode surface, the recognition of thrombin protein, and the reaction with a second biotinylated thrombin aptamer forming the sandwich. Through the exposed biotin end, three variants have been tested to amplify the electrochemical impedance signal. The strategies included (a) silver enhancement treatment, (b) gold enhancement treatment and (c) insoluble product produced by the combination of the enzyme horseradish peroxidase (HRP) and 3-amino-9-ethylcarbazole (AEC). The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the ferrocyanide/ferricyanide redox marker. Insoluble product strategy and silver enhancement treatment resulted in the lowest detection limit (0.3 pM), while gold enhancement method resulted in the highest reproducibility, 8.8% RSD at the pM thrombin concentration levels. Results of silver and gold enhancement treatment also permitted direct inspection by scanning electron microscopy (SEM). - Highlights: • Aptasensor to detect thrombin reaching the femtomolar level. • Biosensing protocol employs two thrombin aptamers in a sandwich capture scheme. • Use of second biotinylated aptamer allows many amplification and detection variants. • Precipitation reaction provides the highest signal amplification of ca. 3 times. • Double recognition event improves remarkably selectivity for thrombin detection.

  19. Three different signal amplification strategies for the impedimetric sandwich detection of thrombin

    International Nuclear Information System (INIS)

    Ocaña, Cristina; Valle, Manel del

    2016-01-01

    In this work, we report a comparative study on three highly specific amplification strategies for the ultrasensitive detection of thrombin with the use of aptamer sandwich protocol. The protocol consisted on the use of a first thrombin aptamer immobilized on the electrode surface, the recognition of thrombin protein, and the reaction with a second biotinylated thrombin aptamer forming the sandwich. Through the exposed biotin end, three variants have been tested to amplify the electrochemical impedance signal. The strategies included (a) silver enhancement treatment, (b) gold enhancement treatment and (c) insoluble product produced by the combination of the enzyme horseradish peroxidase (HRP) and 3-amino-9-ethylcarbazole (AEC). The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the ferrocyanide/ferricyanide redox marker. Insoluble product strategy and silver enhancement treatment resulted in the lowest detection limit (0.3 pM), while gold enhancement method resulted in the highest reproducibility, 8.8% RSD at the pM thrombin concentration levels. Results of silver and gold enhancement treatment also permitted direct inspection by scanning electron microscopy (SEM). - Highlights: • Aptasensor to detect thrombin reaching the femtomolar level. • Biosensing protocol employs two thrombin aptamers in a sandwich capture scheme. • Use of second biotinylated aptamer allows many amplification and detection variants. • Precipitation reaction provides the highest signal amplification of ca. 3 times. • Double recognition event improves remarkably selectivity for thrombin detection.

  20. Quantitative assessment of hyperspectral imaging in detection of plasmonic nanoparticles: a modified contrast-detail analysis approach

    Science.gov (United States)

    Wang, Jianting; Chen, Yu; Pfefer, T. Joshua

    2016-03-01

    Hyperspectral reflectance imaging (HRI) is an emerging imaging modality being applied for clinical indications such as tissue oximetry, and cancer detection based on endogenous biological constituents including plasmonic nanoparticles. However, there is currently a lack of standardized test methods for objective, quantitative evaluation of HRI system performance. Contrast-detail analysis (CDA) is a phantom-based test method commonly used to evaluate medical imaging devices (e.g., mammography systems) in terms of their lower detection limit. We investigated a modified CDA (mCDA) method to quantify the detectability of gold nanoparticles by HRI systems. Silicone-based turbid phantoms containing micro-fluidic channels were developed for the mCDA tests. Polydimethylsiloxane (PDMS) phantom materials were doped with chromophores and scatterers to achieve biologically relevant optical properties (OPs). Molds were used to produce cylindrical channels of diameters 0.3 to 1.65 mm and depths of 0.2 mm inside the phantoms. Channels were filled with a mixture of hemoglobin and concentrations of gold nanorods (GNR) and measured with our HRI system. The contrast of GNRs was solved with a spectral unmixing algorithm from the reflectance spectra. The lowest detectable concentration was determined as a function of inclusion size and depth and plotted as modified contrast detail curve (mCDC). mCDCs were used to compare the detectabilities of the HRI system with different data processing algorithms. It is demonstrated that our mCDA test method involving turbid microchannel phantoms can help to elucidate the combined performance of imaging devices and plasmonic nanoparticle contrast agents. This approach may be useful for performing clinical trial standardization and device re-calibration, thus ensuring quality control and clinical performance.

  1. Paracetamol (acetaminophen) protein adduct concentrations during therapeutic dosing.

    Science.gov (United States)

    Heard, Kennon; Green, Jody L; Anderson, Victoria; Bucher-Bartelson, Becki; Dart, Richard C

    2016-03-01

    Paracetamol protein adducts (PPA) are a biomarker of paracetamol exposure. PPA are quantified as paracetamol-cysteine (APAP-CYS), and concentrations above 1.1 μmol l(-1) have been suggested as a marker of paracetamol-induced hepatotoxicity. However, there is little information on the range of concentrations observed during prolonged therapeutic dosing. The aim of the present study was to describe the concentration of PPA in the serum of subjects taking therapeutic doses of paracetamol for at least 16 days. Preplanned secondary aim of a prospective randomized controlled (placebo vs. 4g day(-1) paracetamol) trial. We measured subjects' serum PPA concentrations every 3 days for a minimum of 16 days. We also measured concentrations on study days 1-3 and 16-25 in subsets of patients. PPA were quantified as APAP-CYS after gel filtration and protein digestion using liquid chromatography/mass spectrometry. Ninety per cent of subjects had detectable PPA after five doses. Median APAP-CYS concentrations in paracetamol-treated subjects increased to a plateau of 0.1 μmol l(-1) on day 7, where they remained. The highest concentration measured was 1.1 μmol l(-1) and two subjects never had detectable PPA levels. PPA were detected in the serum of 78% of subjects 9 days after their final dose. PPA are detectable in the vast majority of subjects taking therapeutic doses of paracetamol. While most have concentrations well below the threshold associated with hepatotoxicity, concentrations may approach 1.1 μmol l(-1) in rare cases. Adducts are detectable after a few doses and can persist for over a week after dosing is stopped. © 2015 The British Pharmacological Society.

  2. Quantitative SERS detection of low-concentration aromatic polychlorinated biphenyl-77 and 2,4,6-trinitrotoluene.

    Science.gov (United States)

    Bao, Zhi Yong; Liu, Xin; Chen, Y; Wu, Yucheng; Chan, Helen L W; Dai, Jiyan; Lei, Dang Yuan

    2014-09-15

    This paper reports a simple label-free high-sensitive method for detecting low-concentration persistent organic pollutants and explosive materials. The proposed method combines surface-enhanced Raman spectroscopy (SERS) and magnetomotive enrichment of the target molecules on the surface of Ag nanoparticles (NPs). This structure can be achieved through self-assembling integration of Ag NPs with ferromagnetic Fe3O4 microspheres, forming a hybrid SERS nanoprobe with both optical and magnetic properties. Moreover, the magnetic response of ferromagnetic Fe3O4 microspheres can be used to dynamically modulate the optical property of Ag NPs through controlling their geometric arrangement on the substrate by applying an external magnetic field. It is also demonstrated from the full-wave numerical simulation results that the maximum electromagnetic field enhancement can be greatly increased by shortening the distance of neighboring Ag NPs and therefore resulting in an improved SERS detecting limit. More importantly, by using the prepared substrate, the SERS signals from organic pollution substances, i.e. aromatic polychlorinated biphenyl-77 and 2,4,6-trinitrotoluene, were quantitatively analyzed. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Low plasma triiodothyronine concentrations and outcome in preterm infants.

    Science.gov (United States)

    Lucas, A; Rennie, J; Baker, B A; Morley, R

    1988-01-01

    A major association has been found between low plasma triiodothyronine concentrations in preterm neonates and their later developmental outcome. Plasma triiodothyronine concentration was measured longitudinally in 280 preterm infants below 1850 g birth weight. Babies whose lowest recorded concentration was less than 0.3 nmol/l had, at 18 months' corrected age, 8.3 and 7.4 point disadvantages in Bayley mental and motor scales and a 8.6 point disadvantage on the academic scale of Developmental Profile II, even after adjusting for a range of antenatal and neonatal factors known to influence later development. Low concentrations of triiodothyronine were strongly associated with infant mortality, but not after adjusting for the presence of respiratory illness. There was no association between plasma triiodothyronine concentrations and somatic growth up to 18 months, and no association with necrotising enterocolitis or later cerebral palsy. Data on postnatal changes in plasma triiodothyronine concentrations are presented for reference purposes. While cited reference ranges for plasma triiodothyronine concentration appear suitable for well infants above 1500 g birth weight, smaller or ill babies often have very low values for many weeks. Our data are relevant to the debate on endocrine 'replacement' treatment in premature babies. PMID:2461683

  4. [Perioperative fibrinogen concentrations in cardiac surgery with cardiopulmonary bypass].

    Science.gov (United States)

    Uji, Makiko; Terada, Yuki; Noguchi, Teruo; Nishida, Takaya; Hasuwa, Kyoko; Shinohara, Kozue; Kumano, Hotaka; Ishimura, Naoko; Nishiwada, Makoto

    2012-08-01

    Patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) need many blood products due to deficiency of coagulation factors. Blood transfusion therapy in patients with excessive bleeding after CPB is generally empiric. We checked and studied the fibrinogen concentration and transfusion, as well as bleeding amount in the perioperative period. The study was approved by our institutional ethics committee. Thirty patients were studied. Blood samples were obtained at the induction of anesthesia (before CPB), at the end of CPB, at the end of operation, and on the next morning, or before the patient was given fresh frozen plasma in the intensive care unit. For all cases, fibrinogen concentration and platelet concentration were lowest at the end of CPB. Fibrinogen concentration rose up to before CPB level on the next morning. The group in which fibrinogen concentration was less than 150 mg x dl(-1) at the end of CPB consumed more blood products than the group with fibrinogen concentration of over 150 mg x dl(-1). Blood transfusion therapy based on fibrinogen concentration is needed to maintain adequacy of the perioperative blood transfusion and blood conservation in cardiac surgery.

  5. In vitro fermentation pattern and acidification potential of different sources of carbohydrates for ruminants given high concentrate diets

    Energy Technology Data Exchange (ETDEWEB)

    Amanzougarene, Z.; Yuste, S.; Vega, A. De; Fondevila, M.

    2017-07-01

    The in vitro fermentation pattern of five sources of carbohydrates of differing nature (maize grain, MZ; sucrose, SU; wheat bran, WB; sugarbeet pulp, BP; and citrus pulp, CT) under conditions of high concentrate diets for ruminants was studied. A first 8 h incubation trial was performed under optimal pH using inoculum from ewes given a fibrous diet, to compare fermentative characteristics of substrates. As planned, incubation pH ranged within 6.3 to 6.6. The gas produced from CT was higher than MZ, SU and BP from 4 and 6 h onwards, and at 8 h, respectively (p<0.05). There were no differences (p>0.05) on total volatile fatty acid (VFA) concentration, nor on acetate or propionate proportions, but butyrate was lowest (p<0.05) with CT and BP. The second incubation trial was performed in a poorly-buffered medium, with inoculum from ewes given a concentrate diet. All substrates showed a gradual drop of pH, being lowest with SU after 4 h (p<0.05). Throughout the incubation, gas production was highest with CT and lowest with MZ and BP (p<0.05). Total 8 h VFA concentration was higher with CT than BP, SU and MZ (p<0.05). Acetate proportion was higher, and that of propionate lower, with BP than WB (p<0.05), butyrate proportion being higher with MZ and WB than with BP and CT (p<0.05). Lactic acid concentration was higher (p<0.05) with SU than WB and BP. Fermentation characteristics and acidification potential of feeds depend on the nature of their carbohydrate fraction, and must be considered for practical applications.

  6. Hydrogel-Forming Microneedle Arrays Allow Detection of Drugs and Glucose In Vivo: Potential for Use in Diagnosis and Therapeutic Drug Monitoring.

    Directory of Open Access Journals (Sweden)

    Ester Caffarel-Salvador

    Full Text Available We describe, for the first time the use of hydrogel-forming microneedle (MN arrays for minimally-invasive extraction and quantification of drug substances and glucose from skin in vitro and in vivo. MN prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride (11.1% w/w and poly(ethyleneglycol 10,000 daltons (5.6% w/w and crosslinked by esterification swelled upon skin insertion by uptake of fluid. Post-removal, theophylline and caffeine were extracted from MN and determined using HPLC, with glucose quantified using a proprietary kit. In vitro studies using excised neonatal porcine skin bathed on the underside by physiologically-relevant analyte concentrations showed rapid (5 min analyte uptake. For example, mean concentrations of 0.16 μg/mL and 0.85 μg/mL, respectively, were detected for the lowest (5 μg/mL and highest (35 μg/mL Franz cell concentrations of theophylline after 5 min insertion. A mean concentration of 0.10 μg/mL was obtained by extraction of MN inserted for 5 min into skin bathed with 5 μg/mL caffeine, while the mean concentration obtained by extraction of MN inserted into skin bathed with 15 μg/mL caffeine was 0.33 μg/mL. The mean detected glucose concentration after 5 min insertion into skin bathed with 4 mmol/L was 19.46 nmol/L. The highest theophylline concentration detected following extraction from a hydrogel-forming MN inserted for 1 h into the skin of a rat dosed orally with 10 mg/kg was of 0.363 μg/mL, whilst a maximum concentration of 0.063 μg/mL was detected following extraction from a MN inserted for 1 h into the skin of a rat dosed with 5 mg/kg theophylline. In human volunteers, the highest mean concentration of caffeine detected using MN was 91.31 μg/mL over the period from 1 to 2 h post-consumption of 100 mg Proplus® tablets. The highest mean blood glucose level was 7.89 nmol/L detected 1 h following ingestion of 75 g of glucose, while the highest mean glucose concentration

  7. Reopening abandoned forest roads in northern Idaho, USA: Quantification of runoff, sediment concentration, infiltration, and interrill erosion parameters

    Science.gov (United States)

    R. B. Foltz; N. S. Copeland; W. J. Elliot

    2009-01-01

    This study measured runoff and sediment concentration from the tire track and from the non-tire track to determine infiltration, interrill erodibility, and vegetative cover impacts of reopening an abandoned forest road. Runoff was lowest on the non-track portion of the abandoned road and highest on the reopened road. Sediment concentrations were significantly higher on...

  8. Fiber Bragg Grating Sensor for Detection of Nitrate Concentration in Water

    Directory of Open Access Journals (Sweden)

    A. S. LALASANGI

    2011-02-01

    Full Text Available The concentrations of chemical species in drinking water are of great interest. We demonstrated etched fiber Bragg grating (FBG as a concentration sensor for nitrate by analyzing the Bragg wavelength shift with concentration of chemical solution. The FBG is fabricated by phase mask technique on single mode Ge-B co-doped photosensitive fiber. Sensitivity of FBGs to the surrounding solution concentration can be enhanced by reducing diameter of the cladding with 40 % HF solution. The maximum sensitivity achieved is 1.322 ´ 10-3 nm/ppm. The overall shift of Bragg wavelength is of the order of 6.611 ´ 10-2 nm for 10 to 50 ppm concentration.

  9. Steam generators of Phenix: Measurement of the hydrogen concentration in sodium for detecting water leaks in the steam generator tubes

    International Nuclear Information System (INIS)

    Cambillard, E.; Lacroix, A.; Langlois, J.; Viala, J.

    1975-01-01

    The Phenix secondary circuits are provided with measurement systems of hydrogen concentration in sodium, that allow for the detection of possible water leaks in steam generators and the location of a faulty module. A measurement device consists of : a detector with nickel membranes of 0, 3 mm wall thickness, an ion pump with a 200 l/s flow rate, a quadrupole mass spectrometer and a calibrated hydrogen leak. The temperature correction is made automatically. The main tests carried out on the leak detection systems are reported. Since the first system operation (October 24, 1973), the measurements allowed us to obtain the hydrogen diffusion rates through the steam generator tube walls. (author)

  10. Environmentally relevant pyrethroid mixtures: A study on the correlation of blood and brain concentrations of a mixture of pyrethroid insecticides to motor activity in the rat.

    Science.gov (United States)

    Hughes, Michael F; Ross, David G; Starr, James M; Scollon, Edward J; Wolansky, Marcelo J; Crofton, Kevin M; DeVito, Michael J

    2016-06-01

    Human exposure to multiple pyrethroid insecticides may occur because of their broad use on crops and for residential pest control. To address the potential health risk from co-exposure to pyrethroids, it is important to understand their disposition and toxicity in target organs such as the brain, and surrogates such as the blood when administered as a mixture. The objective of this study was to assess the correlation between blood and brain concentrations of pyrethroids and neurobehavioral effects in the rat following an acute oral administration of the pyrethroids as a mixture. Male Long-Evans rats were administered a mixture of β-cyfluthrin, cypermethrin, deltamethrin, esfenvalerate and cis- and trans-permethrin in corn oil at seven dose levels. The pyrethroid with the highest percentage in the dosing solution was trans-permethrin (31% of total mixture dose) while deltamethrin and esfenvalerate had the lowest percentage (3%). Motor activity of the rats was then monitored for 1h. At 3.5h post-dosing, the animals were euthanized and blood and brain were collected. These tissues were extracted and analyzed for parent pyrethroid using HPLC-tandem mass spectrometry. Cypermethrin and cis-permethrin were the predominate pyrethroids detected in blood and brain, respectively, at all dosage levels. The relationship of total pyrethroid concentration between blood and brain was linear (r=0.93). The pyrethroids with the lowest fraction in blood were trans-permethrin and β-cyfluthrin and in brain were deltamethrin and esfenvalerate. The relationship between motor activity of the treated rats and summed pyrethroid blood and brain concentration was described using a sigmoidal Emax model with the Effective Concentration50 being more sensitive for brain than blood. The data suggests summed pyrethroid rat blood concentration could be used as a surrogate for brain concentration as an aid to study the neurotoxic effects of pyrethroids administered as a mixture under the conditions

  11. Highly sensitive and selective detection of dopamine using one-pot synthesized highly photoluminescent silicon nanoparticles.

    Science.gov (United States)

    Zhang, Xiaodong; Chen, Xiaokai; Kai, Siqi; Wang, Hong-Yin; Yang, Jingjing; Wu, Fu-Gen; Chen, Zhan

    2015-03-17

    A simple and highly efficient method for dopamine (DA) detection using water-soluble silicon nanoparticles (SiNPs) was reported. The SiNPs with a high quantum yield of 23.6% were synthesized by using a one-pot microwave-assisted method. The fluorescence quenching capability of a variety of molecules on the synthesized SiNPs has been tested; only DA molecules were found to be able to quench the fluorescence of these SiNPs effectively. Therefore, such a quenching effect can be used to selectively detect DA. All other molecules tested have little interference with the dopamine detection, including ascorbic acid, which commonly exists in cells and can possibly affect the dopamine detection. The ratio of the fluorescence intensity difference between the quenched and unquenched cases versus the fluorescence intensity without quenching (ΔI/I) was observed to be linearly proportional to the DA analyte concentration in the range from 0.005 to 10.0 μM, with a detection limit of 0.3 nM (S/N = 3). To the best of our knowledge, this is the lowest limit for DA detection reported so far. The mechanism of fluorescence quenching is attributed to the energy transfer from the SiNPs to the oxidized dopamine molecules through Förster resonance energy transfer. The reported method of SiNP synthesis is very simple and cheap, making the above sensitive and selective DA detection approach using SiNPs practical for many applications.

  12. Heterogeneity at the CETP gene locus. Influence on plasma CETP concentrations and HDL cholesterol levels

    NARCIS (Netherlands)

    Kuivenhoven, J.A.; de Knijff, P.; Boer, J M; Smalheer, H A; Botma, G.J.; Seidell, J C; Kastelein, J.J.; Pritchard, P H

    This study was designed to investigate the association(s) between heterogeneity at the cholesteryl ester transfer protein (CETP) gene locus, CETP plasma concentrations, and HDL cholesterol levels. Healthy men with the lowest, median, and highest deciles of HDL cholesterol were selected from a large

  13. Copper clean-up procedure for ultrasonic extraction and analysis of pyrethroid and phenylpyrazole pesticides in sediments by gas chromatography-electron capture detection

    International Nuclear Information System (INIS)

    Wu Jun; Lin Youjian; Lu Jian; Wilson, Chris

    2011-01-01

    A rapid ultrasonic extraction method coupled with a heated-copper clean-up procedure for removing interfering constituents was developed for analyzing pyrethroid and phenylpyrazole pesticides in sediments. Incubation of the 60 mL extract with 12 g copper granules at 60 o C for 2 h was determined to be the optimal conditions for removing the interfering constituents. Eleven pyrethroid and phenylpyrazole pesticides were spiked into sediment samples to determine the effectiveness of the ultrasonic extraction method. The average recoveries of pyrethroids and phenylpyrazoles in sediment at 4 o C storage on day 0, 1, 7, 14, and 21 ranged from 98.6 to 120.0%, 79.2 to 116.0%, 85.0 to 119.7%, 93.6 to 118.7%, and 92.1 to 118.2%, respectively, with all percent relative standard deviations less than 10% (most o C. Recoveries of the pesticides ranged from 98.6% to 120.0% for lowest fortification level (2-16 μg kg -1 ), from 97.8% to 117.9% for middle fortification level (10-80 μg kg -1 ), and from 94.3% to 118.1% for highest fortification level (20-160 μg kg -1 ). Relative standard deviations of pesticide recoveries were usually less than 7%. Method detection limits of target pesticides ranged from 0.22 μg kg -1 to 3.72 μg kg -1 . Furthermore, field sediment samples collected from four residential lakes during a three-month monitoring period were analyzed to evaluate the effectiveness of this method. Bifenthrin was detected in all of sediment samples (highest concentration 260.33 ± 41.71 μg kg -1 , lowest concentration 5.68 ± 0.38 μg kg -1 ), and fipronil sulfone was detected at least once in sediment samples collected from three sites with concentrations ranging from 1.73 ± 0.53 to 7.53 ± 0.01 μg kg -1 . - Highlights: → A rapid extraction and copper-based clean-up method was developed. → Recoveries after storage at 4 o C for 21 d ranged from 79.2 to 120.0%. → Percent relative standard deviations less than 10% (most -1 to 3.72 μg kg -1 .

  14. Elastic recoil detection analysis for the determination of hydrogen concentration profiles in switchable mirrors

    International Nuclear Information System (INIS)

    Huisman, M.C.; Molen, S.J. van der; Vis, R.D.

    1999-01-01

    Switchable mirrors [J.N. Huiberts, R. Griessen, J.H. Rector, R.J. Wijngaarden, J.P. Dekker, D.G. de Groot, N.J. Koeman, Nature 380 (1996) 231; J.N Huiberts, J.H. Rector, R.J. Wijngaarden, S. Jetten, D. de Groot, B. Dam, N.J.. Koeman, R. Griessen, B. Hjoervarsson, S Olafsson, Y.S. Cho, J. Alloys and Compounds 239 (1996) 158; F.J.A. den Broeder, S.J. van der Molen, M. Kremers, J. N. Huiberts, D.G. Nagengast, A.T.M. van Gogh, W.H. Huisman, N. J. Koeman, B. Dam, J.H. Rector, S. Plota, M. Haaksma, R.M.N. Hanzen, R.M. Jungblut, P.A. Duine, R. Griessen, Nature 394 (1998) 656] made of thin films of Y, La or rare-earth (RE) metals exhibit spectacular changes in their optical and electrical properties upon hydrogen loading. The study of these materials has indicated that the occurring phenomena are highly sensitive to the actual hydrogen concentration in these materials. In this paper elastic recoil detection analysis (ERDA) is used as a tool to measure hydrogen concentrations on a micrometer scale. The measurements have been performed using a 4 He 2+ ion beam from a 1.7 MV Pelletron accelerator. The ion beam can be focused routinely to a spot size of approximately 10 μm 2 . The experimental set-up enables the simultaneous measurement of Rutherford backscattering spectrometry (RBS) as well as particle induced X-ray emission (PIXE) spectra, which provide complementary information. The results of ERDA measurements on laterally diffused YH x (0< x<3) samples with a qualitatively known hydrogen concentration profile are presented and discussed. The calibration of the microbeam set-up and possible improvement of the measurement technique are described

  15. Elastic recoil detection analysis for the determination of hydrogen concentration profiles in switchable mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Huisman, M.C. E-mail: huisman@nat.vu.nl; Molen, S.J. van der; Vis, R.D

    1999-09-02

    Switchable mirrors [J.N. Huiberts, R. Griessen, J.H. Rector, R.J. Wijngaarden, J.P. Dekker, D.G. de Groot, N.J. Koeman, Nature 380 (1996) 231; J.N Huiberts, J.H. Rector, R.J. Wijngaarden, S. Jetten, D. de Groot, B. Dam, N.J.. Koeman, R. Griessen, B. Hjoervarsson, S Olafsson, Y.S. Cho, J. Alloys and Compounds 239 (1996) 158; F.J.A. den Broeder, S.J. van der Molen, M. Kremers, J. N. Huiberts, D.G. Nagengast, A.T.M. van Gogh, W.H. Huisman, N. J. Koeman, B. Dam, J.H. Rector, S. Plota, M. Haaksma, R.M.N. Hanzen, R.M. Jungblut, P.A. Duine, R. Griessen, Nature 394 (1998) 656] made of thin films of Y, La or rare-earth (RE) metals exhibit spectacular changes in their optical and electrical properties upon hydrogen loading. The study of these materials has indicated that the occurring phenomena are highly sensitive to the actual hydrogen concentration in these materials. In this paper elastic recoil detection analysis (ERDA) is used as a tool to measure hydrogen concentrations on a micrometer scale. The measurements have been performed using a {sup 4}He{sup 2+} ion beam from a 1.7 MV Pelletron accelerator. The ion beam can be focused routinely to a spot size of approximately 10 {mu}m{sup 2}. The experimental set-up enables the simultaneous measurement of Rutherford backscattering spectrometry (RBS) as well as particle induced X-ray emission (PIXE) spectra, which provide complementary information. The results of ERDA measurements on laterally diffused YH{sub x} (0concentration profile are presented and discussed. The calibration of the microbeam set-up and possible improvement of the measurement technique are described.

  16. Diagnostic value of Joint Detection of GP73 and AFP-L3 in Primary Hepatic Carcinoma with Low Concentration of AFP

    Directory of Open Access Journals (Sweden)

    Lei CAI

    2015-03-01

    Full Text Available Objective: To explore the applicative value of serum Golgi protein (GP73 and alpha-proteinvariant (AFP-L3 in the diagnosis of patients with primary hepatic carcinoma (PHC. Methods:Totally 110 patients were enrolled, including 60 PHC patients with low concentration of AFP ((1.1-108.0 μg/L and 50 patients with non-PHC digestive system diseases (20 cases of patients with chronic hepatitis, 15 patients with liver cirrhosis, 4 patients with bile duct cancer, 4 patients with gastric cancer, 4 patients with rectal cancer and 3 patients with colon cancer. In addition, 42 healthy people were selected as control group. GP73 was detected by enzyme-linked immunosorbent assay (ELISA trace centrifugal column method was adopted for separation of AFP-L3. Luo's chemiluminescence method was used to determine the total content of AFP and AFP-L3 in eluent for calculating the ratio of AFP-L3/ AFP. Results: The levels of serum GP73 and AFP-L3(% in PHC group were significantly higher than the other 2 groups (P<0.01 and the level of serum GP73 and AFP-L3 (% in Non-PHC group were higher than those in healthy group (P<0.01. ROC analysis showed that the area under ROC curve of single GP73 and AFP-L3(% in diagnosis of PHC and non-PHC were 0.887 and 0.860, respectively. Additionally, the ROC analysis also showed that critical value of GP73 and AFP-L3 for the diagnosis of HPC were 83.78 μg/L and 13.87%, respectively. The sensitivity of joint detection of serum GP73 or AFP-L3 was higher than detection of them alone (90.0 vs. 71.7 and 60.0, P<0.05 but the specificity was similar between single detection and joint detection (P>0.05. The positive predictive value and negative predictive value of joint detection of them was higher than single detections of them and there was significant differences in negative predictive value (P<0.05 but no difference in positive predictive value (P>0.05. The overall response rate of joint detection of GP73 and AFP-L3 was higher

  17. Copper and zinc concentrations in serum of healthy Greek adults

    International Nuclear Information System (INIS)

    Kouremenou-Dona, Eleni; Dona, Artemis; Papoutsis, John; Spiliopoulou, Chara

    2006-01-01

    Serum copper and zinc concentrations of 506 (414 males and 92 females) apparently healthy Greek blood donors aged 18-60 years old were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 115.46 ± 23.56 μg/dl and 77.11 ± 17.67 μg/dl, respectively. The mean value for copper and zinc in females was higher than in males, although the difference for zinc was smaller than the one observed for copper. When the subjects were divided into various age groups there appeared to be some increase in copper concentration as a function of age, whereas zinc concentration did not change. There were no significant variations in serum copper and zinc concentrations due to place of residence, occupation and socioeconomic status. This study is the first one evaluating the serum status of copper and zinc in healthy Greeks and it has shown that they are at the highest concentration range for copper and the lowest for zinc compared to literature data on copper and zinc levels for various countries

  18. Copper and zinc concentrations in serum of healthy Greek adults

    Energy Technology Data Exchange (ETDEWEB)

    Kouremenou-Dona, Eleni [A' Hospital of IKA, Athens (Greece); Dona, Artemis [Department of Forensic Medicine and Toxicology, Medical School, University of Athens, M. Asias 75, Goudi, 11527 Athens (Greece)]. E-mail: artedona@med.uoa.gr; Papoutsis, John [Department of Forensic Medicine and Toxicology, Medical School, University of Athens, M. Asias 75, Goudi, 11527 Athens (Greece); Spiliopoulou, Chara [Department of Forensic Medicine and Toxicology, Medical School, University of Athens, M. Asias 75, Goudi, 11527 Athens (Greece)

    2006-04-15

    Serum copper and zinc concentrations of 506 (414 males and 92 females) apparently healthy Greek blood donors aged 18-60 years old were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 115.46 {+-} 23.56 {mu}g/dl and 77.11 {+-} 17.67 {mu}g/dl, respectively. The mean value for copper and zinc in females was higher than in males, although the difference for zinc was smaller than the one observed for copper. When the subjects were divided into various age groups there appeared to be some increase in copper concentration as a function of age, whereas zinc concentration did not change. There were no significant variations in serum copper and zinc concentrations due to place of residence, occupation and socioeconomic status. This study is the first one evaluating the serum status of copper and zinc in healthy Greeks and it has shown that they are at the highest concentration range for copper and the lowest for zinc compared to literature data on copper and zinc levels for various countries.

  19. Amanitin and phallotoxin concentration in Amanita phalloides var. alba mushroom.

    Science.gov (United States)

    Kaya, Ertugrul; Yilmaz, Ismail; Sinirlioglu, Zeynep Aydin; Karahan, Selim; Bayram, Recep; Yaykasli, Kursat Oguz; Colakoglu, Serdar; Saritas, Ayhan; Severoglu, Zeki

    2013-12-15

    Although rarely seen, Amanita phalloides var. alba, a variety of A. phalloides type mushrooms, causes mushroom poisoning resulting in death. Since it is frequently confused with some edible mushrooms due to its white colored cap and macroscopic appearance, it becomes important in toxicological terms. Knowledge of the toxin amount contained in this mushroom type is invaluable in the treatment of cases involving poisoning. In this study, we examined the toxin levels of various parts of the A. phalloides var. alba mushroom growing Duzce region of Turkey. Toxin analyses were carried out for A. phalloides var. alba, which were collected from the forests Duzce region of Turkey in 2011, as a whole and also separately in its spore, pileus, gills, stipe and volva parts. The alpha amanitin, beta amanitin, gamma amanitin, phalloidin and phallacidine analyses of the mushrooms were carried out using the RP-HPLC method. A genetic analysis of the mushroom showed that it had similar genetic characteristics as A. phalloides and was a variety of it. The lowest toxins quantity was detected in spores, volva and stipe among all parts of the mushroom. The maximum amount of amatoxins was measured in the gills. The pileus also contained a high amount of amatoxins. Generally, amatoxins and phallotoxin concentrations were lower as compared to A. phalloides, but interestingly all toxins other than gamma toxin were higher in the spores of A. phalloides var. alba. The amount of toxin in all of its parts had sufficient concentrations to cause death. With this study, the amatoxin and phallotoxin concentrations in A. phalloides var. alba mushroom and in its parts have been revealed in detail for the first time. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Rotational structure of the five lowest frequency fundamental vibrational states of dimethylsulfoxide

    Science.gov (United States)

    Cuisset, Arnaud; Drumel, Marie-Aline Martin; Hindle, Francis; Mouret, Gaël; Sadovskií, Dmitrií A.

    2013-10-01

    We report on the successful extended analysis of the high-frequency (200-700 GHz) part of the gas phase (sub)mm-wave spectra of dimethylsulfoxide (DMSO). The spectrum was recorded at 100 kHz resolution using a solid state subTHz spectrometer. The five lowest energy fundamental vibrational states of DMSO with frequencies below 400 cm-1 were observed as sidebands along with the main 0←0 band. Neglecting the internal rotation of methyls, our rotational Hamiltonian reproduced the spectrum to the subMHz accuracy. We have found that the asymmetric bending state ν23 is the only low frequency fundamental vibrational state with the "anomalous" rotational structure uncovered in Cuisset et al. [1]. dmsomw 2013-09-04 15:03

  1. Superhydrophobic analyte concentration utilizing colloid-pillar array SERS substrates.

    Science.gov (United States)

    Wallace, Ryan A; Charlton, Jennifer J; Kirchner, Teresa B; Lavrik, Nickolay V; Datskos, Panos G; Sepaniak, Michael J

    2014-12-02

    The ability to detect a few molecules present in a large sample is of great interest for the detection of trace components in both medicinal and environmental samples. Surface enhanced Raman spectroscopy (SERS) is a technique that can be utilized to detect molecules at very low absolute numbers. However, detection at trace concentration levels in real samples requires properly designed delivery and detection systems. The following work involves superhydrophobic surfaces that have as a framework deterministic or stochastic silicon pillar arrays formed by lithographic or metal dewetting protocols, respectively. In order to generate the necessary plasmonic substrate for SERS detection, simple and flow stable Ag colloid was added to the functionalized pillar array system via soaking. Native pillars and pillars with hydrophobic modification are used. The pillars provide a means to concentrate analyte via superhydrophobic droplet evaporation effects. A ≥ 100-fold concentration of analyte was estimated, with a limit of detection of 2.9 × 10(-12) M for mitoxantrone dihydrochloride. Additionally, analytes were delivered to the surface via a multiplex approach in order to demonstrate an ability to control droplet size and placement for scaled-up uses in real world applications. Finally, a concentration process involving transport and sequestration based on surface treatment selective wicking is demonstrated.

  2. {sup 226}Ra concentrations in crayfish tissues, water, and sediments from the Serpent River Basin in Northeastern Ontario, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Alikhan, M.A. [Laurentian Univ., Sudbury, ON (Canada). Dept of Biology

    1996-12-31

    Lower Serpent River, as well as Elliot, McCarthy and McCabe lakes had highest {sup 226}Ra contamination, Chrisman, Quirke and Whiskey lakes a moderate one, Flack and Semiwhite lakes and the `distant` control, Lake Wanapitei, the lowest. {sup 226}Ra activity in Cambarus robustus tissues was directly related to their background levels. Thus, concentration coefficient (tissue/sediment concentrations) for {sup 226}Ra ranged from 0.53 to 0.74 in highly contaminated Elliot and McCarthy lakes, 0.28 to 0.59 in moderately contaminated Quirke and Whiskey lakes, and from 0.27 to 3.44 in least contaminated Semiwhite and Flack lakes. Among various organs analysed, exoskeleton showed the highest (43.04 - 90.69%) and the tail muscles the lowest (2.95 -17.14%) {sup 226}Ra activity. {sup 226}Ra concentrations in the alimentary canal were considered a part of the ambient environment as they had not been absorbed. 12 refs, 1 fig, 1 tab.

  3. Correlation between air flow rate and pollutant concentrations during two-stage oak log combustion in a 25 KW residential boiler

    Directory of Open Access Journals (Sweden)

    Juszczak Marek

    2016-09-01

    Full Text Available It can be expected that there is a considerable correlation between combustion air flow rate and the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas. The influence of temperature and oxygen concentration in the combustion zone on the concentrations of carbon monoxide, hydrocarbons and nitrogen oxide in the flue gas, for high and low combustion air flow, was analysed. Oxygen concentration for which the concentration of carbon monoxide is the lowest was determined, as well as the mutual relation between carbon monoxide and nitrogen oxide concentration.

  4. Computer simulation of 2D grain growth using a cellular automata model based on the lowest energy principle

    International Nuclear Information System (INIS)

    He Yizhu; Ding Hanlin; Liu Liufa; Shin, Keesam

    2006-01-01

    The morphology, topology and kinetics of normal grain growth in two-dimension were studied by computer simulation using a cellular automata (Canada) model based on the lowest energy principle. The thermodynamic energy that follows Maxwell-Boltzmann statistics has been introduced into this model for the calculation of energy change. The transition that can reduce the system energy to the lowest level is chosen to occur when there is more than one possible transition direction. The simulation results show that the kinetics of normal grain growth follows the Burke equation with the growth exponent m = 2. The analysis of topology further indicates that normal grain growth can be simulated fairly well by the present CA model. The vanishing of grains with different number of sides is discussed in the simulation

  5. Annexin V–CLIO: A Nanoparticle for Detecting Apoptosis by MRI

    Directory of Open Access Journals (Sweden)

    Eyk A. Schellenberger

    2002-04-01

    Full Text Available Annexin V, which recognizes the phosphatidylserine of apoptotic cells, was conjugated to crosslinked iron oxide (CLIO nanoparticles, a functionalized superparamagnetic preparation developed for target-specific magnetic resonance imaging (MRI. The resulting nanoparticle had an average of 2.7 annexin V proteins linked per CLIO nanoparticle through disulfide bonds. Using camptothecin to induce apoptosis, a mixture of Jurkat T cells (69% healthy and 31% apoptotic was incubated with annexin V–CLIO and was applied to magnetic columns. The result was an almost complete removal of the apoptotic cells (>99%. In a phantom MRI experiment, untreated control cells (12% apoptotic cells, 88% healthy cells and camptothecin-treated cells (65% apoptotic cells, 35% healthy cells were incubated with either annexin V–CLIO (1.0, 0.5, and 0.1 μg Fe/mL or with unlabeled CLIO. A significant signal decrease of camptothecin-treated cells relative to untreated cells was observed even at the lowest concentration tested. Unmodified CLIO failed to cause a significant signal change of apoptotic cells. Hence, annexin V–CLIO allowed the identification of cell suspensions containing apoptotic cells by MRI even at very low concentrations of magnetic substrate. Conjugation of annexin V to CLIO affords a strategy for the development of a MRI imaging probe for detecting apoptosis.

  6. Search for the lowest irradiation dose from literatures on radiation-induced cancer in gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T [Tokyo Univ. (Japan). Faculty of Medicine

    1976-05-01

    A survey of past case reports about radiation-induced cancer in the gastrointestinal tract was carried out with the main object of finding the lowest irradiation dose. Search of the literature published since 1923 revealed 80 cases of radiation-induced large intestine cancer and one case of stomach cancer. The cases of radiation-induced cancer in the large intestine had received radiation for the treatment of non-malignant conditions, fibroma, ovarial cyste, myoma, endometritis and duodenal ulcer. The lowest irradiation dose was estimated at 460 rads. Adenocarcinoma was the histopathological finding in all cases of radiation-induced cancer in the caecum, colon and rectum, and squamous cell carcinoma in the cases of anal cancer. The latent period ranged from 1 to 31 years, with the average of 13.6 years. There were some reports of statistical studies of radiation-induced stomach cancer. Three groups were the subjects of these studies. The first group was composed of atomic bomb survivors, the second of patients who had undergone radiation treatment for ankylosing spondilitis, and the third of duodenal ulcer patients subjected to radiation treatment for the purpose of suppressing gastric acid secretion. These statistical studies showed no significant increase of the incidence of stomach cancer in the irradiated groups.

  7. Search for the lowest irradiation dose from literatures on radiation-induced cancer in gastrointestinal tract

    International Nuclear Information System (INIS)

    Yoshizawa, Yasuo; Kusama, Tomoko

    1976-01-01

    A survey of past case reports about radiation-induced cancer in the gastrointestinal tract was carried out with the main object of finding the lowest irradiation dose. Search of the literature published since 1923 revealed 80 cases of radiation-induced large intestine cancer and one case of stomach cancer. The cases of radiation-induced cancer in the large intestine had received radiation for the treatment of non-malignant conditions, fibroma, ovarial cyste, myoma, endometritis and duodenal ulcer. The lowest irradiation dose was estimated at 460 rads. Adenocarcinoma was the histopathological finding in all cases of radiation-induced cancer in the caecum, colon and rectum, and squamous cell carcinoma in the cases of anal cancer. The latent period ranged from 1 to 31 years, with the average of 13.6 years. There were some reports of statistical studies of radiation-induced stomach cancer. Three groups were the subjects of these studies. The first group was composed of atomic bomb survivors, the second of patients who had undergone radiation treatment for ankylosing spondilitis, and the third of duodenal ulcer patients subjected to radiation treatment for the purpose of suppressing gastric acid secretion. These statistical studies showed no significant increase of the incidence of stomach cancer in the irradiated groups. (auth.)

  8. Potential energies for the two lowest 1A' electronic states of H3+

    International Nuclear Information System (INIS)

    Ichihara, Akira; Yokoyama, Keiichi; Iwamoto, Osamu

    1998-11-01

    Potential energies for the two lowest 1 A' states of H 3 + at 701 different spatial geometries are tabulated. These energies have been calculated by the ab initio full configuration interaction method with a (8s6p2d1f) Gaussian type basis set. Features of avoided crossing of two surfaces as well as the potential well in the ground state can be produced by interpolating calculated energies. These ab initio energies are expressed as a function of three internuclear distances in the range from 0.6 to 10.0 bohr, and they are applicable to the molecular dynamics study for the H + + H 2 system. (author)

  9. A study of radon-222 concentrations in North Carolina groundwater

    International Nuclear Information System (INIS)

    Evans, J.P.

    1992-01-01

    The groundwater of 400 North Carolina homes was sampled to ascertain the distribution and extent of 222 Rn in North Carolina groundwater. Arithmetic mean (AM) and geometric mean (GM) concentrations of 1,816 pCi L -1 and 656 pCi L -1 were found for the state. These results indicate that two-thirds of 114 degree C. homes served by groundwater exceed the EPA proposed 300 pCi L -1 maximum contaminant level (MCL). Only 2% of NC homes exceeded 10,000 pCi L-1. The Eastern region had the lowest radon concentrations by far, with a GM of 2-)0 pCi L -1 . The Central region and Western region had GM's of 794 pCi L -1 and 1,032 pCi L -1 respectively. The groundwater data approached a log normal distribution. No consistent trends were noted in the relationship between indoor radon concentrations and groundwater radon concentrations. A correlation coefficient of 0.00921 revealed a very weak linear relationship

  10. Detecting peptidic drugs, drug candidates and analogs in sports doping: current status and future directions.

    Science.gov (United States)

    Thevis, Mario; Thomas, Andreas; Schänzer, Wilhelm

    2014-12-01

    With the growing availability of mature systems and strategies in biotechnology and the continuously expanding knowledge of cellular processes and involved biomolecules, human sports drug testing has become a considerably complex field in the arena of analytical chemistry. Proving the exogenous origin of peptidic drugs and respective analogs at lowest concentration levels in biological specimens (commonly blood, serum and urine) of rather limited volume is required to pursue an action against cheating athletes. Therefore, approaches employing chromatographic-mass spectrometric, electrophoretic, immunological and combined test methods have been required and developed. These allow detecting the misuse of peptidic compounds of lower (such as growth hormone-releasing peptides, ARA-290, TB-500, AOD-9604, CJC-1295, desmopressin, luteinizing hormone-releasing hormones, synacthen, etc.), intermediate (e.g., insulins, IGF-1 and analogs, 'full-length' mechano growth factor, growth hormone, chorionic gonadotropin, erythropoietin, etc.) and higher (e.g., stamulumab) molecular mass with desired specificity and sensitivity. A gap between the technically possible detection and the day-to-day analytical practice, however, still needs to be closed.

  11. Detection, concentrations and distribution of paxilline, an animal neurotoxin, in mouse brain: an application of ultra-high sensitivity detection of 14C by accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Roberts, P.B.; Kim, K.

    1999-01-01

    Full text: Paxilline is an intermediate in the biosynthesis of lolitrem neurotoxins that cause the disorder rye grass staggers in livestock grazing on pastures infected with certain fungi. Paxilline itself produces similar symptoms and the 14 C-labelled compound has been produced bio-synthetically at low specific activity. Using conventional liquid scintillation counting it was not possible to detect the labelled compound in the brain of mice sacrificed at the time they displayed physiological symptoms. Accelerator mass spectrometry (AMS) counts 14 C atoms, not decays, and provides sensitivity 10,000-100,000 times greater than conventional scintillation counting of radioactive decays. Measurements are easily obtained at the level of the natural abundance of 14 C in living tissue of 6fCi or 10 -16 moles 14 C per mg total carbon. Extraction of the labelled compound from the tissue is unnecessary and sample size can be 0.01-10mg. Paxilline (8mg/kg ip) was given to 25g mice. The total activity injected was 11,000 dpm though the results showed that 1,000dpm would have been sufficient. The concentration of paxilline in homogenised whole brain was determined to be 985 pg or 0.0075 dpm mg dry tissue. The concentration in the major brain segments ranged from 893-1137 pgmg dry tissue. The spinal cord contained 719 pg/mg dry tissue. Our results suggest that toxicologists and pharmacologists should consider what new information may be obtained by combining tracer studies with the power of AMS detection. The AMS method makes possible great reductions in the amount of label and sample sizes, plus wider ranges in concentration/time course studies. In particular, it opens up new possibilities such as: studies at true dietary or environmental levels; tracer studies in large animal or plant systems; field trials; human studies where radiation dose must be considered; and studies with compounds that can only be synthesised with low specific activity. Copyright (1999) Australasian

  12. Study of different 3-aminopropyl triethoxysilane (APTES) concentration on TiO2 particles based IDE for cervical cancer detection

    Science.gov (United States)

    Raqeema, S.; Hashim, U.; Azizah, N.; Nadzirah, Sh.; Arshad, M. K. Md; Ruslinda, A. R.; Gopinath, Subash C. B.

    2017-03-01

    HPV that also called Human Papillomaviruses is the major cause of the cervical cancer. HPV 16 and HPV 18 are the two types of HPV are the most HPV-associated cancers and responsible as a high-risk HPV. Cervical cancer taken about 70 percent of all cases due HPV infections. Cervical malignancy for the most part development on a lady's cervix and its was developed slowly as cancer disease. TiO2 particles give better performance and low cost of the biosensor. The used of 3-aminopropyl triethoxysilane (APTES) will be more efficient for DNA nanochip. APTES used as absorption reaction to immobilize organic biomolecules on the inorganic surface. Besides, APTES give better functionalization of the adsorption mechanism on IDE. The surface functionalized for immobilizing the DNA, which is the combination of the DNA probe and the HPV target produce high sensitivity andfast detection of the IDE. The Current-Voltage (IV) characteristic proved the sensitivity of the DNA nanochip increase as the concentration varied from 0% concentration to 24% of APTES concentration.

  13. Validity of the lowest-Landau-level approximation for rotating Bose gases

    International Nuclear Information System (INIS)

    Morris, Alexis G.; Feder, David L.

    2006-01-01

    The energy spectrum for an ultracold rotating Bose gas in a harmonic trap is calculated exactly for small systems, allowing the atoms to occupy several Landau levels. Two vortexlike states and two strongly correlated states (the Pfaffian and Laughlin) are considered in detail. In particular, their critical rotation frequencies and energy gaps are determined as a function of particle number, interaction strength, and the number of Landau levels occupied (up to three). For the vortexlike states, the lowest-Landau-level (LLL) approximation is justified only if the interaction strength decreases with the number of particles; nevertheless, the constant of proportionality increases rapidly with the angular momentum per particle. For the strongly correlated states, however, the interaction strength can increase with particle number without violating the LLL condition. The results suggest that, in large systems, the Pfaffian and Laughlin states might be stabilized at rotation frequencies below the centrifugal limit for sufficiently large interaction strengths, with energy gaps a significant fraction of the trap energy

  14. Investigation of contactless detection using a giant magnetoresistance sensor for detecting prostate specific antigen.

    Science.gov (United States)

    Sun, Xuecheng; Zhi, Shaotao; Lei, Chong; Zhou, Yong

    2016-08-01

    This paper presents a contactless detection method for detecting prostate specific antigen with a giant magnetoresistance sensor. In contactless detection case, the prostate specific antigen sample preparation was separated from the sensor that prevented the sensor from being immersed in chemical solvents, and made the sensor implementing in immediately reuse without wash. Experimental results showed that applied an external magnetic field in a range of 50 Oe to 90 Oe, Dynabeads with a concentration as low as 0.1 μg/mL can be detected by this system and could give an approximate quantitation to the logarithmic of Dynabeads concentration. Sandwich immunoassay was employed for preparing PSA samples. The PSA capture was implemented on a gold film modified with a self-assembled monolayer and using biotinylated secondary antibody against PSA and streptavidinylated Dynabeads. With DC magnetic field in the range of 50 to 90 Oe, PSA can be detected with a detection limit as low as 0.1 ng/mL. Samples spiked with different concentrations of PSA can be distinguished clearly. Due to the contactless detection method, the detection system exhibited advantages such as convenient manipulation, reusable, inexpensive, small weight. So, this detection method was a promising candidate in biomarker detection, especially in point of care detection.

  15. The DTU15 MSS (Mean Sea Surface) and DTU15LAT (Lowest Astronomical Tide) reference surface

    DEFF Research Database (Denmark)

    Andersen, Ole Baltazar; Stenseng, Lars; Piccioni, Gaia

    in the Arctic Ocean for DTU10MSS and DTU13MSS.A new reference surface for off-shore vertical referencing is introduced. This is called the DTU15LAT.The surface is derived from the DTU15MSS and the DTU10 Global ocean tide to give a 19 year Lowest Astronomical Tide referenced to either the Mean sea surface...

  16. Distribution of {sup 210}Pb and {sup 210}Po concentrations in wild berries and mushrooms in boreal forest ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Vaaramaa, Kaisa, E-mail: Kaisa.Vaaramaa@Helsinki.fi [Laboratory of Radiochemistry, Department of Chemistry, P.O. Box 55, FI-00014 University of Helsinki (Finland); Solatie, Dina [STUK-Radiation and Nuclear Safety Authority, Regional Laboratory in Northern Finland, FI-96500 Rovaniemi (Finland); Aro, Lasse [Finnish Forest Research Institute (METLA), Parkano Research Unit, FI-39700 Parkano (Finland)

    2009-12-15

    The activity concentrations and distribution of {sup 210}Pb and {sup 210}Po in wild berries and edible mushrooms were investigated in Finnish forests. The main study areas were located in Scots pine (Pinus sylvestris L.) forests in southern and northern Finland. The activity concentrations of {sup 210}Pb and {sup 210}Po in blueberry (Vaccinium myrtillus L.) and lingonberry (Vaccinium vitis-idaea L.) samples decreased in the order: stems > leaves > berries (i.e. fruits). The activity ratios of {sup 210}Po/{sup 210}Pb in the wild berry samples were mainly higher than one, indicating elevated activity concentrations of polonium in the samples. In mushrooms the activity concentrations of {sup 210}Pb and especially {sup 210}Po were higher than in fruits of the wild berries. The highest activity concentration of {sup 210}Pb was detected in Cortinarius armillatus L. (16.2 Bq kg{sup -1} d.w.) and the lowest in Leccinum vulpinum L. (1.38 Bq kg{sup -1} d.w.). The {sup 210}Po activity concentrations of the whole fruiting bodies ranged from 7.14 Bq kg{sup -1} d.w. (Russula paludosa L.) to 1174 Bq kg{sup -1} d.w. (L. vulpinum L.). In general, the highest activity concentrations of {sup 210}Po were recorded in boletes. The caps of mushrooms of the Boletaceae family showed higher activity concentrations of {sup 210}Po compared to the stipes. In most of the mushrooms analyzed, the activity concentrations of {sup 210}Po were higher than those of {sup 210}Pb. {sup 210}Po and {sup 210}Pb dominate the radiation doses received via ingestion of wild berries and mushrooms in northern Finland, while in southern Finland the ingested dose is dominated by {sup 137}Cs from the Chernobyl fallout.

  17. Variation in chemical composition and physical characteristics of cereal grains from different genotypes

    DEFF Research Database (Denmark)

    Rodehutscord, Markus; Rückert, Christine; Maurer, Hans Peter

    2016-01-01

    . The mean lysine concentration of protein was the highest in oats (4.2 g/16 g N) and the lowest in wheat (2.7 g/16 g N). Significant differences were also detected in the concentrations of macro elements as well as iron, manganese, zinc and copper. Concentrations of arsenic, cadmium and lead were below...... the limit of detection. The concentration of lower inositol phosphates was low, but some inositol pentaphosphates were detected in all grains. In barley, relatively high inositol tetraphosphate concentration also was found. Intrinsic phytase activity was the highest in rye, followed by triticale, wheat...

  18. Temporal variation of carbonyl compound concentrations at a semi-rural site in Denmark

    DEFF Research Database (Denmark)

    Christensen, C.S.; Skov, H.; Nielsen, T.

    2000-01-01

    The atmospheric concentrations of formaldehyde, acetaldehyde and acetone were measured by the DNPH-technique at the semi-rural site Lille Valby, Denmark (55 degrees N) between May-July 1995, The average concentrations were observed to be 1.2 ppbv for formaldehyde, 0.8 ppbv for acetaldehyde and 1.......9 ppbv for acetone, For the set of carbonyl compounds, concentrations were found to be highly correlated, though only during daytime, The weak correlations observed during nighttime are believed to be caused by the dry deposition of especially formaldehyde, During periods with low photochemical activity...... of hydrocarbons during long-range transport. Especially, the concentration levels of acetone showed a pronounced seasonal-variation with the highest levels observed during summertime and lowest in winter and spring. The seasonal variation in the concentration levels of formaldehyde and acetaldehyde were small...

  19. Airborne concentrations of Polybrominated diethyl etherin residential homes

    Directory of Open Access Journals (Sweden)

    S. Rahimzadeh

    2009-07-01

    Full Text Available Background and aims   Polybrominated diphenyl ethers (PBDE have been widely applied to different home and offices' appliances as flame retardant additives to inhibit ignition and enhance  the fire safety. Their toxicity, health effects, and resistance to environmental degradation are  matters of great interested among scientists. Airborne concentrations of PBDE in residential  homes were determined in this study.   Methods   In a cross sectional study, 33 residential homes were selected and airborne concentrations of PBDEs were investigated using PUF disk passive air samplers. Also in two building the concentraction of PBDEs were monitored in two rooms of a department in each building for 12 months.   Results   Average airborne concentration of ?PBDE (sum of congener #s 17, 28, 47, 49, 66, 85, 99, 100, 153, and 154 for all locations monitored was 52 (4-245 pgm -3 . While in one of the buildings the contaminant level of bedroom was significantly higher than the living room, PBDE   concentrations remained relatively constant for whole monitoring period.   Conclusion   The range of concentrations results to a wide variation between inhalation intakes of dwellers of the lowest and the highest contaminated homes (~50 folds.  

  20. Pt-MWCNT modified carbon electrode strip for rapid and quantitative detection of H2O2 in food

    Directory of Open Access Journals (Sweden)

    Tai-Cheng Chou

    2018-04-01

    Full Text Available A single-use screen-printed carbon electrode strip was designed and fabricated. Nanohybrids, prepared by deposition of platinum (Pt nanoparticles on multi-wall carbon nanotube (MWCNT, was modified on the surface of screen-printed carbon electrode for the development of a fast, sensitive and cost-effective hydrogen peroxide (H2O2 detection amperometric sensor strip. With Pt-MWCNT nanohybrids surface modification, current generated in response to H2O2 by the screen-printed carbon electrode strip was enhanced 100 fold with an applied potential of 300 mV. Quality of as-prepared electrode strip was assured by the low coefficient of variation (CV (<5% of currents measured at 5 s. Three linear detection ranges with sensitivity of 75.2, 120.7, and 142.8 μA mM−1 cm−2 were observed for H2O2 concentration in the range of 1–15 mM, 0.1–1 mM, and 10–100 μM, respectively. The lowest H2O2 concentration could be measured by the as-prepared strip was 10 μM. H2O2 levels in green tea infusion and pressed Tofu could be rapidly detected with results comparable to that measured by ferrous oxidation xylenol orange (FOX assay and peroxidase colorimetric method. Keywords: Platinum-multi-wall carbon nanotube (Pt-MWCNT, Disposable carbon electrode, Hydrogen peroxide (H2O2, Amperometric sensor

  1. Final survey reports on radon concentration in Japan

    International Nuclear Information System (INIS)

    1997-03-01

    In order to grasp the present state of indoor radon concentration all over Japan, this survey was conducted in five years from Heisei 4 FY to 8 FY. Measurements were conducted using a radon and thoron separation apparatus so as to enable to develop radon and thoron separately. This was only one survey all over Japan obtained the only radon concentration by removing thoron perfectly. However, it was planned to obtain the mean indoor radon concentration all over Japan by limiting 20 houses for measurement aim because of limitation on numbers of the apparatus. In this survey, no extremely high region of the radon concentration was found. However, it was comparatively higher in Chugoku, Kinki and Kyushu-Okinawa areas, but was comparatively low in Kanto area. These results showed the same tendency as those of γ-ray level from the ground, and the radon concentration also showed temperature difference of a tendency of higher west and lower east. In this survey, seasonal variation of the radon concentration was found. In the third quarter (from October to December) maximum radon concentration (mean value: 15 Bq/cu m) and in the second quarter, the minimum concentration (mean value: 9 Bq/cu m) were observed, respectively. On comparing the indoor radon concentration of each housing structure used in enquete survey, concrete block house showed higher radon concentration. On its arithmetic mean, the radon concentration was high in order of concrete, steel frame, and wood constructions, and lowest in prefabricated house. The radon concentration of the concrete construction showed about 1.8 times higher than that of the wood construction. (G.K.)

  2. Lowest cost due to highest productivity and highest quality

    Science.gov (United States)

    Wenk, Daniel

    2003-03-01

    Since global purchasing in the automotive industry has been taken up all around the world there is one main key factor that makes a TB-supplier today successful: Producing highest quality at lowest cost. The fact that Tailored Blanks, which today may reach up to 1/3 of a car body weight, are purchased on the free market but from different steel suppliers, especially in Europe and NAFTA, the philosophy on OEM side has been changing gradually towards tough evaluation criteria. "No risk at the stamping side" calls for top quality Tailored- or Tubular Blank products. Outsourcing Tailored Blanks has been starting in Japan but up to now without any quality request from the OEM side like ISO 13919-1B (welding quality standard in Europe and USA). Increased competition will automatically push the quality level and the ongoing approach to combine high strength steel with Tailored- and Tubular Blanks will ask for even more reliable system concepts which enables to weld narrow seams at highest speed. Beside producing quality, which is the key to reduce one of the most important cost driver "material scrap," in-line quality systems with true and reliable evaluation is going to be a "must" on all weld systems. Traceability of all process related data submitted to interfaces according to customer request in combination with ghost-shift-operation of TB systems are tomorrow's state-of-the-art solutions of Tailored Blank-facilities.

  3. Indoor radon concentrations in the coastal and central regions of Montenegro

    International Nuclear Information System (INIS)

    Vukotic, Perko; Antovic, Nevenka; Svrkota, Ranko

    2008-01-01

    This paper presents the results of the first systematic indoor radon survey in Montenegro, in 10 municipalities of its coastal and central regions. In rural areas one home was randomly selected in each 5 x 5 km square of a regular grid covering the territory of Montenegro, while in urban areas the basic grid was subdivided into 0.5 x 0.5 km squares, and in each of them one building was selected and one dwelling within the building. In each of these 434 homes, radon measurements were performed twice a year, using passive dosimeters placed in the living room or bedroom on the ground floor or the first floor. The CR-39 nuclear track detectors were exposed each time for about six months. The annual average radon concentrations in the surveyed homes are found to be log normally distributed (GM = 49.6 Bq m -3 , GSD 3.2) within the range 2-2,208 Bq m -3 . Their arithmetic mean is 105 Bq m -3 and median 41.4 Bq m -3 . Radon concentrations above the action level of 400 Bq m -3 are detected in 5.6% of the surveyed homes. Most of these 24 homes are detached single-family houses, and the majority are rural. Radon concentrations were generally higher in detached family houses than in apartment buildings, in older than in newer houses, and higher in rural than in urban homes. As to the domestic radon exposure, this survey indicates reinforced concrete as the most favorable and stones as the most unfavorable of the building materials commonly used in Montenegro. The lowest average effective dose is in urban homes on the Montenegrin Coast (0.80 mSv y -1 ), while the highest is in the rural area of the Niksic municipality (7.31 mSv y - 1 ) , which is abundant in bauxite deposits. (author)

  4. Detecting Lamb waves with broadband acousto-ultrasonic signals in composite structures

    Science.gov (United States)

    Kautz, Harold E.

    1992-01-01

    Lamb waves can be produced and detected in ceramic matrix composites (CMC) and metal matrix composites (MMC) plates using the acousto-ultrasonic configuration employing broadband transducers. Experimental dispersion curves of lowest symmetric and lowest antisymmetric modes behave in a manner analogous to the graphite/polymer theoretical curves. In this study a basis has been established for analyzing Lamb wave velocities for characterizing composite plates. Lamb wave disperison curves and group velocities were correlated with variations in axial stiffness and shear stiffness in MMC and CMC. For CMCs, interfacial shear strength was also correlated with the first antisymmetric Lamb mode.

  5. Kepler planet-detection mission

    DEFF Research Database (Denmark)

    Borucki...[], William J.; Koch, David; Buchhave, Lars C. Astrup

    2010-01-01

    The Kepler mission was designed to determine the frequency of Earth-sized planets in and near the habitable zone of Sun-like stars. The habitable zone is the region where planetary temperatures are suitable for water to exist on a planet’s surface. During the first 6 weeks of observations, Kepler...... is one of the lowest-density planets (~0.17 gram per cubic centimeter) yet detected. Kepler-5b, -6b, and -8b confirm the existence of planets with densities lower than those predicted for gas giant planets....

  6. An Aqueous Two-Phase System for the Concentration and Extraction of Proteins from the Interface for Detection Using the Lateral-Flow Immunoassay.

    Directory of Open Access Journals (Sweden)

    Ricky Y T Chiu

    Full Text Available The paper-based immunoassay for point-of-care diagnostics is widely used due to its low cost and portability over traditional lab-based assays. Lateral-flow immunoassay (LFA is the most well-established paper-based assay since it is rapid and easy to use. However, the disadvantage of LFA is its lack of sensitivity in some cases where a large sample volume is required, limiting its use as a diagnostic tool. To improve the sensitivity of LFA, we previously reported on the concentration of analytes into one of the two bulk phases of an aqueous two-phase system (ATPS prior to detection. In this study, we preserved the advantages of LFA while significantly improving upon our previous proof-of-concept studies by employing a novel approach of concentrating gold nanoparticles, a common LFA colorimetric indicator. By conjugating specific antibodies and polymers to the surfaces of the particles, these gold nanoprobes (GNPs were able to capture target proteins in the sample and subsequently be concentrated within 10 min at the interface of an ATPS solution comprised of polyethylene glycol, potassium phosphate, and phosphate-buffered saline. These GNPs were then extracted and applied directly to LFA. By combining this prior ATPS interface extraction with LFA, the detection limit of LFA for a model protein was improved by 100-fold from 1 ng/μL to 0.01 ng/μL. Additionally, we examined the behavior of the ATPS system in fetal bovine serum and synthetic urine to more closely approach real-world applications. Despite using more complex matrices, ATPS interface extraction still improved the detection limit by 100-fold within 15 to 25 min, demonstrating the system's potential to be applied to patient samples.

  7. An Aqueous Two-Phase System for the Concentration and Extraction of Proteins from the Interface for Detection Using the Lateral-Flow Immunoassay.

    Science.gov (United States)

    Chiu, Ricky Y T; Thach, Alison V; Wu, Chloe M; Wu, Benjamin M; Kamei, Daniel T

    2015-01-01

    The paper-based immunoassay for point-of-care diagnostics is widely used due to its low cost and portability over traditional lab-based assays. Lateral-flow immunoassay (LFA) is the most well-established paper-based assay since it is rapid and easy to use. However, the disadvantage of LFA is its lack of sensitivity in some cases where a large sample volume is required, limiting its use as a diagnostic tool. To improve the sensitivity of LFA, we previously reported on the concentration of analytes into one of the two bulk phases of an aqueous two-phase system (ATPS) prior to detection. In this study, we preserved the advantages of LFA while significantly improving upon our previous proof-of-concept studies by employing a novel approach of concentrating gold nanoparticles, a common LFA colorimetric indicator. By conjugating specific antibodies and polymers to the surfaces of the particles, these gold nanoprobes (GNPs) were able to capture target proteins in the sample and subsequently be concentrated within 10 min at the interface of an ATPS solution comprised of polyethylene glycol, potassium phosphate, and phosphate-buffered saline. These GNPs were then extracted and applied directly to LFA. By combining this prior ATPS interface extraction with LFA, the detection limit of LFA for a model protein was improved by 100-fold from 1 ng/μL to 0.01 ng/μL. Additionally, we examined the behavior of the ATPS system in fetal bovine serum and synthetic urine to more closely approach real-world applications. Despite using more complex matrices, ATPS interface extraction still improved the detection limit by 100-fold within 15 to 25 min, demonstrating the system's potential to be applied to patient samples.

  8. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    Science.gov (United States)

    Bordelon, Hali; Russ, Patricia K; Wright, David W; Haselton, Frederick R

    2013-01-01

    Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3) to 5×10(8) copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6), 14×10(6), and 8×10(6) copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  9. Measurement of the lowest dosage of phenobarbital that can produce drug discrimination in rats

    Science.gov (United States)

    Overton, Donald A.; Stanwood, Gregg D.; Patel, Bhavesh N.; Pragada, Sreenivasa R.; Gordon, M. Kathleen

    2009-01-01

    Rationale Accurate measurement of the threshold dosage of phenobarbital that can produce drug discrimination (DD) may improve our understanding of the mechanisms and properties of such discrimination. Objectives Compare three methods for determining the threshold dosage for phenobarbital (D) versus no drug (N) DD. Methods Rats learned a D versus N DD in 2-lever operant training chambers. A titration scheme was employed to increase or decrease dosage at the end of each 18-day block of sessions depending on whether the rat had achieved criterion accuracy during the sessions just completed. Three criterion rules were employed, all based on average percent drug lever responses during initial links of the last 6 D and 6 N sessions of a block. The criteria were: D%>66 and N%50 and N%33. Two squads of rats were trained, one immediately after the other. Results All rats discriminated drug versus no drug. In most rats, dosage decreased to low levels and then oscillated near the minimum level required to maintain criterion performance. The lowest discriminated dosage significantly differed under the three criterion rules. The squad that was trained 2nd may have benefited by partially duplicating the lever choices of the previous squad. Conclusions The lowest discriminated dosage is influenced by the criterion of discriminative control that is employed, and is higher than the absolute threshold at which discrimination entirely disappears. Threshold estimations closer to absolute threshold can be obtained when criteria are employed that are permissive, and that allow rats to maintain lever preferences. PMID:19082992

  10. Detection of Dirofilaria immitis and other arthropod-borne filarioids by an HRM real-time qPCR, blood-concentrating techniques and a serological assay in dogs from Costa Rica.

    Science.gov (United States)

    Rojas, Alicia; Rojas, Diana; Montenegro, Víctor M; Baneth, Gad

    2015-03-23

    Canine filarioids are important nematodes transmitted to dogs by arthropods. Diagnosis of canine filariosis is accomplished by the microscopic identification of microfilariae, serology or PCR for filarial-DNA. The aim of this study was to evaluate a molecular assay for the detection of canine filariae in dog blood, to compare its performance to other diagnostic techniques, and to determine the relationship between microfilarial concentration and infection with other vector-borne pathogens. Blood samples from 146 dogs from Costa Rica were subjected to the detection of canine filarioids by four different methods: the microhematocrit tube test (MCT), Knott's modified test, serology and a high resolution melt and quantitative real-time PCR (HRM-qPCR). Co-infection with other vector-borne pathogens was also evaluated. Fifteen percent of the dogs were positive to Dirofilaria immitis by at least one of the methods. The HRM-qPCR produced distinctive melting plots for the different filarial worms and revealed that 11.6% of dogs were infected with Acanthocheilonema reconditum. The latter assay had a limit of detection of 2.4x10⁻⁴ mf/μl and detected infections with lower microfilarial concentrations in comparison to the microscopic techniques and the serological assay. The MCT and Knott's test only detected dogs with D. immitis microfilaremias above 0.7 mf/μl. Nevertheless, there was a strong correlation between the microfilarial concentration obtained by the Knott's modified test and the HRM-qPCR (r = 0.906, p HRM-qPCR showed the most sensitive and reliable performance in the detection of blood filaroids in comparison to the Knott's modified test, the MCT test and a serological assay.

  11. A dual chemosensor: Colorimetric detection of Co{sup 2+} and fluorometric detection of Zn{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seong Youl; Kim, So Young; Kim, Jin Ah; Kim, Cheal, E-mail: chealkim@seoultech.ac.kr

    2016-11-15

    A new dual chemosensor 1was designed and synthesized. Receptor 1 detected Co{sup 2+} via color change and Zn{sup 2+} with turn-on fluorescence in a 1:1stoichiometric system, respectively. The response mechanisms of 1-Co{sup 2+} and 1-Zn{sup 2+} complexes have been analyzed using UV–vis spectroscopy, fluorescence titration, ESI-mass spectrometry analysis, NMR titration and DFT calculations. Importantly, the detection limit of 1 for Co{sup 2+}was down to 0.34 μM a near-perfect aqueous solution, which is the lowest one among those previously reported for organic chemosensors for sensing of Co{sup 2+}. 1 was also used to quantify Co{sup 2+} in real water samples. Therefore, a versatile chemosensor 1 could be a great method for detecting of both Co{sup 2+} and Zn{sup 2+}.

  12. Radiometers for radon concentration in air

    International Nuclear Information System (INIS)

    Bartak, J.; Machaj, B.; Pienkos, J.P.

    2002-01-01

    Constant grow of science and technology stimulates development of new improved measuring tools. New measuring demand arise also in radon concentration measurements. Varying rock stress and rock cracks influencing radon emanation encouraged research aimed at use of this phenomenon to predict crumps of mine formation among others based on variation of radon emanation. A measuring set was developed in the Institute of Nuclear Chemistry and Technology enabling long term monitoring of radon concentration in mine bore-hole. The set consists probe and probe controller. Detection threshold of the probe is 230 Bq/m 3 . The set can operate in the environment with methane explosion hazard. A radiometer employing Lucas cell as radiation detector for radon concentration in air was also developed its detection threshold is approx. 10 Bq/m 3 . Replaceable Lucas cell of the radiometer allows for measurement of high as well as low radon concentration in short time interval. (author)

  13. Spatial temporal determination of phosphorus concentration in Lake Tota

    International Nuclear Information System (INIS)

    Cordero, Ruben D; Ruiz, J Efraim; Vargas, Edgar F

    2005-01-01

    The lapse from July to November of 2003 a study was made to determine the spatial and temporal concentration of phosphorus in the lake of Tota (Boyaca, Colombia). Samples were taken with a Van-Dorn bottle of the horizontal type of two-liter capacity in the superficial stratum up to 20 cm in the water column and at 10 m depth. The different forms of phosphorus studied, show that there are significant differences in their concentrations, the highest values being found in the sector known as Lago Chico and the lowest in the area of Lago Grande; this behavior is found to be closely related to the agricultural uses of the land in the littoral zone and additionally with the climatic factors especially the precipitation in the area investigated

  14. Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor

    Directory of Open Access Journals (Sweden)

    Varun Lingaiah Kopparthy

    2015-01-01

    Full Text Available A thermoelectric biosensor for the detection of L-glutamate concentration was developed. The thermoelectric sensor is integrated into a micro-calorimeter which measures the heat produced by biochemical reactions. The device contains a single flow channel that is 120 µm high and 10 mm wide with two fluid inlets and one fluid outlet. An antimony-bismuth (Sb-Bi thermopile with high common mode rejection ratio is attached to the lower channel wall and measures the dynamic changes in the temperature when L-glutamate undergoes oxidative deamination in the presence of glutamate oxidase (GLOD. The thermopile has a Seebeck coefficient of ~7 µV·(m·K−1. The device geometry, together with hydrodynamic focusing, eliminates the need of extensive temperature control. Layer-by-layer assembly is used to immobilize GLOD on the surface of glass coverslips by alternate electrostatic adsorption of polyelectrolyte and GLOD. The impulse injection mode using a 6-port injection valve minimizes sample volume to 5 µL. The sensitivity of the sensor for glutamate is 17.9 nVs·mM−1 in the linear range of 0–54 mM with an R2 value of 0.9873. The lowest detection limit of the sensor for glutamate is 5.3 mM.

  15. [Investigation of concentration levels of chromium(VI) in bottled mineral and spring waters by high performance ion chromatography technique with application of postcolumn reaction with 1,5-diphenylcarbazide and VIS detection].

    Science.gov (United States)

    Swiecicka, Dorota; Garboś, Sławomir

    2008-01-01

    The aim of this work was optimization and validation of the method of determination of Cr(VI) existing in the form of chromate(VI) in mineral and spring waters by High Performance Ion Chromatography (HPIC) technique with application of postcolumn reaction with 1,5-diphenylcarbazide and VIS detection. Optimization of the method performed with the use of initial apparatus parameters and chromatographic conditions from the Method 218.6 allowed to lowering detection limit for Cr(VI) from 400 ng/l to 2 ng/l. Thanks to very low detection limit achieved it was possible to determine of Cr(VI) concentrations in 25 mineral and spring waters presented at Polish market. In the cases of four mineral and spring waters analyzed, determined Cr(VI) concentrations were below of quantification limit (waters the concentrations of chromium(VI) were determined in the range of 5.6 - 1281 ng/l. The fact of existence of different Cr(VI) concentrations in investigated waters could be connected with secondary contamination of mineral and spring waters by chromium coming from metal installations and fittings. One should be underlined that even the highest determined concentration level of chromium(VI) was below of the maximum admissible concentration of total chromium presented in Polish Decree of Minister of Health from April 29th 2004. Therefore after taking into account determined in this work concentration of Cr(VI), the consumption of all waters analyzed in this study does not lead to essential human health risk.

  16. Development of a PCR-RFLP assay for the detection and differentiation of canine parvovirus and mink enteritis virus.

    Science.gov (United States)

    Zhang, Chuanmei; Yu, Yongle; Yang, Haiyan; Li, Guimei; Yu, Zekun; Zhang, Hongliang; Shan, Hu

    2014-12-15

    A polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) assay has been developed to detect and differentiate between canine parvovirus (CPV) and mink enteritis virus (MEV). Eight CPV and three MEV epidemic strains isolated from 28 pathological samples from dogs and minks suspected of being infected with parvovirus were amplified by PCR using a pair of specific primers designed based on the CPV-N strain (M19296). PCR amplified a fragment of 1016bp from the genomic DNA of both MEV and CPV. The MEV-derived fragment could be digested with the restriction enzyme BSP1407I into three fragments of 102bp, 312bp and 602bp, while the fragment amplified from the CPV genomic DNA was digested into only two fragments of 414bp and 602bp. The lowest DNA concentration of CPV and MEV that could be detected using this assay was 0.004μg/ml and 0.03μg/ml, respectively. The PCR-RFLP assay developed in the present study can, therefore, be used to detect and differentiate MEV from CPV with high specificity and sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. [Ultrafine particle number concentration and size distribution of vehicle exhaust ultrafine particles].

    Science.gov (United States)

    Lu, Ye-qiang; Chen, Qiu-fang; Sun, Zai; Cai, Zhi-liang; Yang, Wen-jun

    2014-09-01

    Ultrafine particle (UFP) number concentrations obtained from three different vehicles were measured using fast mobility particle sizer (FMPS) and automobile exhaust gas analyzer. UFP number concentration and size distribution were studied at different idle driving speeds. The results showed that at a low idle speed of 800 rmin-1 , the emission particle number concentration was the lowest and showed a increasing trend with the increase of idle speed. The majority of exhaust particles were in Nuclear mode and Aitken mode. The peak sizes were dominated by 10 nm and 50 nm. Particle number concentration showed a significantly sharp increase during the vehicle acceleration process, and was then kept stable when the speed was stable. In the range of 0. 4 m axial distance from the end of the exhaust pipe, the particle number concentration decayed rapidly after dilution, but it was not obvious in the range of 0. 4-1 m. The number concentration was larger than the background concentration. Concentration of exhaust emissions such as CO, HC and NO showed a reducing trend with the increase of idle speed,which was in contrast to the emission trend of particle number concentration.

  18. Evaluation of Chlorinated Hydrocarbon Concentrations in Tehran’s Districts Drinking Water

    Directory of Open Access Journals (Sweden)

    Alireza Pardakhti

    2012-01-01

    Full Text Available In this study Tehran’s drinking water was evaluated for the presence of chlorinated hydrocarbons during spring and summer of 2009. Chlorinated hydrocarbons are an important class of environmental pollutants that cause adverse health effects on human’s kidney, liver and central nervous systems. In this study six water districts were selected for taking drinking water samples in the city of Tehran as well as one location outside the city limits. The samples were analyzed by GC/MS using EPA method 8260. The average concentrations of 1,1-dichloroethylene, 1,2 Dichloromethane, Tetra chloromethane, Trichloroethylene and tetra chloroethylene were determined during a 7 month period and the results were 0.04ppb, 0.52ppb, 0.01ppb, 0.24ppb, 0.03ppb respectively. The highest concentration of chlorinated hydrocarbon observed in Tehran’s drinking water was Trichloroethylene and the lowest concentration was Tetra chloromethane. Districts 5 and 6 showed the highest concentrations of chlorinated hydrocarbons in the city of Tehran.

  19. Natural and anthropogenic radionuclide activity concentrations in the New Zealand diet.

    Science.gov (United States)

    Pearson, Andrew J; Gaw, Sally; Hermanspahn, Nikolaus; Glover, Chris N

    2016-01-01

    To support New Zealand's food safety monitoring regime, a survey was undertaken to establish radionuclide activity concentrations across the New Zealand diet. This survey was undertaken to better understand the radioactivity content of the modern diet and also to assess the suitability of the current use of milk as a sentinel for dietary radionuclide trends. Thirteen radionuclides were analysed in 40 common food commodities, including animal products, fruits, vegetables, cereal grains and seafood. Activity was detected for (137)Caesium, (90)Strontium and (131)Iodine. No other anthropogenic radionuclides were detected. Activity concentrations of the three natural radionuclides of Uranium and the daughter radionuclide (210)Polonium were detected in the majority of food sampled, with a large variation in magnitude. The maximum activity concentrations were detected in shellfish for all these radionuclides. Based on the established activity concentrations and ranges, the New Zealand diet contains activity concentrations of anthropogenic radionuclides far below the Codex Alimentarius guideline levels. Activity concentrations obtained for milk support its continued use as a sentinel for monitoring fallout radionuclides in terrestrial agriculture. The significant levels of natural and anthropogenic radionuclide activity concentrations detected in finfish and molluscs support undertaking further research to identify a suitable sentinel for New Zealand seafood monitoring. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Comparison of Ground-Based PM2.5 and PM10 Concentrations in China, India, and the U.S.

    Directory of Open Access Journals (Sweden)

    Xingchuan Yang

    2018-07-01

    Full Text Available Urbanization and industrialization have spurred air pollution, making it a global problem. An understanding of the spatiotemporal characteristics of PM2.5 and PM10 concentrations (particulate matter with an aerodynamic diameter of less than 2.5 μm and 10 μm, respectively is necessary to mitigate air pollution. We compared the characteristics of PM2.5 and PM10 concentrations and their trends of China, India, and the U.S. from 2014 to 2017. Particulate matter levels were lowest in the U.S., while China showed higher concentrations, and India showed the highest. Interestingly, significant declines in PM2.5 and PM10 concentrations were found in some of the most polluted regions in China as well as the U.S. No comparable decline was observed in India. A strong seasonal trend was observed in China and India, with the highest values occurring in winter and the lowest in summer. The opposite trend was noted for the U.S. PM2.5 was highly correlated with PM10 for both China and India, but the correlation was poor for the U.S. With regard to reducing particulate matter pollutant concentrations, developing countries can learn from the experiences of developed nations and benefit by establishing and implementing joint regional air pollution control programs.

  1. Transuranic concentrations in reef and pelagic fish from the Marshall Islands

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Eagle, R.J.; Wong, K.M.; Jokela, T.A.

    1980-09-01

    Concentrations of /sup 239 + 240/Pu are reported in tissues of several species of reef and pelagic fish caught at 14 different atolls in the northern Marshall Islands. Several regularities that are species dependent are evident in the distribution of /sup 239 + 240/Pu among different body tissues. Concentrations in liver always exceeded those in bone and concentrations were lowest in the muscle of all fish analyzed. A progressive discrimination against /sup 239 + 240/Pu was observed at successive trophic levels at all atolls except Bikini and Enewetak, where it was difficult to conclude if any real difference exists between the average concentration factor for /sup 239 + 240/Pu among all fish, which include bottom feeding and grazing herbivores, bottom feeding carnivores, and pelagic carnivores from different atoll locations. The average concentration of /sup 239 + 240/Pu in the muscle of surgeonfish from Bikini and Enewetak was not significantly different from the average concentrations determined in these fish at the other, lesser contaminated atolls. Concentrations among all 3rd, 4th, and 5th trophic level species are highest at Bikini where higher environmental concentrations are found. The reasons for the anomalously low concentrations in herbivores from Bikini and Enewetak are not known

  2. Transuranic concentrations in reef and pelagic fish from the Marshall Islands

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Eagle, R.J.; Wong, K.M.; Jokela, T.A.

    1981-01-01

    Concentrations of sup(239+240)Pu are reported in tissues of several species of reef and pelagic fish caught at 14 different atolls in the northern Marshall Islands. Several regularities that are species dependent are evident in the distribution of sup(239+240)Pu among different body tissues. Concentrations in liver always exceeded those in bone and concentrations were lowest in the muscle of all fish analysed. A progressive discrimination against sup(239+240)Pu was observed at successive trophic levels at all atolls except Bikini and Enewetak, where it was difficult to conclude if any real difference exists between the average concentration factor for sup(239+240)Pu among all fish, which include bottom-feeding and grazing herbivores, bottom-feeding carnivores and pelagic carnivores from different atoll locations. The average concentration of sup(239+240)Pu in the muscle of surgeonfish from Bikini and Enewetak was not significantly different from the average concentrations determined in these fish at the other lesser contaminated atolls. Concentrations among all 3rd, 4th and 5th trophic level species are highest at Bikini where higher environmental concentrations are found. The reasons for the anomalously low concentrations in herbivores from Bikini and Enewetak are not known. (author)

  3. Nitrogen concentrations in mosses indicate the spatial distribution of atmospheric nitrogen deposition in Europe

    International Nuclear Information System (INIS)

    Harmens, H.; Norris, D.A.; Cooper, D.M.; Mills, G.; Steinnes, E.; Kubin, E.; Thoeni, L.; Aboal, J.R.; Alber, R.; Carballeira, A.; Coskun, M.; De Temmerman, L.; Frolova, M.; Gonzalez-Miqueo, L.

    2011-01-01

    In 2005/6, nearly 3000 moss samples from (semi-)natural location across 16 European countries were collected for nitrogen analysis. The lowest total nitrogen concentrations in mosses ( 2 = 0.91) linear relationship was found between the total nitrogen concentration in mosses and measured site-specific bulk nitrogen deposition rates. The total nitrogen concentrations in mosses complement deposition measurements, helping to identify areas in Europe at risk from high nitrogen deposition at a high spatial resolution. - Highlights: → Nitrogen concentrations in mosses were determined at ca. 3000 sites across Europe. → Moss concentrations were compared with EMEP modelled nitrogen deposition. → The asymptotic relationship for Europe showed saturation at ca. 15 kg N ha -1 y -1 . → Linear relationships were found with measured nitrogen deposition in some countries. → Moss concentrations complement deposition measurements at high spatial resolution. - Mosses as biomonitors of atmospheric nitrogen deposition in Europe.

  4. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-05-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm²). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD₉₅ was lowest for glass (0.429 CFU/cm² with BAS and 0.341 CFU/cm² with BG) and highest for vinyl tile (0.919 CFU/cm² with BAS and 0.917 CFU/cm² with BG). These mRV-PCR LOD₉₅ values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm² and BG: 0.820 to 1.489 CFU/cm²). The FNR and LOD₉₅ values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  5. False Negative Rates of a Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates via Real-Time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L.D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-01

    Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, and plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm2). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD95 was lowest for glass (0.429 CFU/cm2 with BAS and 0.341 CFU/cm2 with BG) and highest for vinyl tile (0.919 CFU/cm2 with BAS and 0.917 CFU/cm2 with BG). These mRV-PCR LOD95 values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm2 and BG: 0.820 to 1.489 CFU/cm2). The FNR and LOD95 values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.

  6. Refractometric total protein concentrations in icteric serum from dogs.

    Science.gov (United States)

    Gupta, Aradhana; Stockham, Steven L

    2014-01-01

    To determine whether high serum bilirubin concentrations interfere with the measurement of serum total protein concentration by refractometry and to assess potential biases among refractometer measurements. Evaluation study. Sera from 2 healthy Greyhounds. Bilirubin was dissolved in 0.1M NaOH, and the resulting solution was mixed with sera from 2 dogs from which food had been withheld to achieve various bilirubin concentrations up to 40 mg/dL. Refractometric total protein concentrations were estimated with 3 clinical refractometers. A biochemical analyzer was used to measure biuret assay-based total protein and bilirubin concentrations with spectrophotometric assays. No interference with refractometric measurement of total protein concentrations was detected with bilirubin concentrations up to 41.5 mg/dL. Biases in refractometric total protein concentrations were detected and were related to the conversion of refractive index values to total protein concentrations. Hyperbilirubinemia did not interfere with the refractometric estimation of serum total protein concentration. The agreement among total protein concentrations estimated by 3 refractometers was dependent on the method of conversion of refractive index to total protein concentration and was independent of hyperbilirubinemia.

  7. Use of neutron activation analysis to measure the variation in trace element concentrations in a coal seam

    International Nuclear Information System (INIS)

    Fardy, J.J.; Swaine, D.J.

    1985-01-01

    Trace element concentrations were measured by neutron activation on 57 run-of-mine coal samples from several locations in seven mines located in the Lithgow seam in the Western Coalfield, Sydney Basin. Results were tabulated as ratios of the highest to the lowest variance for each element

  8. Chlorination or monochloramination: Balancing the regulated trihalomethane formation and microbial inactivation in marine aquaculture waters

    KAUST Repository

    Sanawar, Huma; Xiong, Yanghui; Alam, Aftab; Croue, Jean-Philippe; Hong, Pei-Ying

    2017-01-01

    at the lowest tested concentration of chlorine (1mg/L) and contact time (1h). Comparatively, regulated THMs concentration was only detectable at 30μg/L level in one of the three sets of monochloraminated marine aquaculture waters. The average log reduction

  9. Investigating high-concentration monoclonal antibody powder suspension in nonaqueous suspension vehicles for subcutaneous injection.

    Science.gov (United States)

    Bowen, Mayumi; Armstrong, Nick; Maa, Yuh-Fun

    2012-12-01

    Developing high-concentration monoclonal antibody (mAb) liquid formulations for subcutaneous (s.c.) administration is challenging because increased viscosity makes injection difficult. To overcome this obstacle, we investigated a nonaqueous powder suspension approach. Three IgG1 mAbs were spray dried and suspended at different concentrations in Miglyol® 840, benzyl benzoate, or ethyl lactate. Suspensions were characterized for viscosity, particle size, and syringeability; physical stability was visually inspected. Suspensions generally outperformed liquid solutions for injectability despite higher viscosity at the same mAb concentrations. Powder formulations and properties had little effect on viscosity or injectability. Ethyl lactate suspensions had lowest viscosity (Miglyol® 840 improved overall performance in high mAb concentration suspensions. This study demonstrated the viability of high mAb concentration (>300 mg/mL) in suspension formulations for s.c. administration. Copyright © 2012 Wiley Periodicals, Inc.

  10. Radio refractivity gradients in the lowest 100m of the atmosphere over Lagos, Nigeria in the rainy-harmattan transition phase

    Science.gov (United States)

    Dairo, O. F.; Kolawole, L. B.

    2018-01-01

    Radio engineers and researchers in conjunction with the International Telecommunication Union (ITU) have established the pivotal role of radio refractivity to the propagation of electromagnetic energy in the troposphere. In particular, the refractivity gradient statistics for the lowest 100m in the troposphere are used to determine the probability of occurrence of anomalous propagation conditions known as ducting. The major challenge to characterising the propagation condition over any environment is accessing the data of the lowest boundary layer of the atmosphere, which is highly dynamic and turbulent in evolution. High resolution radiosonde data from the Nigerian Meteorological Agency (NiMet) were used for a synoptic study of the rain-harmattan transition phase. The rain-harmattan transition phase marks the onset of the dry season due to the movement of the intertropical convergence zone interplay between (north-easterly and south-westerly) trade winds and monsoonal circulation. The lowest 100m data were analysed to determine the frequency of ducting per month. Progressive increase in the occurrence of ducting was observed during the rain-harmattan transition phase, which coincides with the West African Monsoon retreat. The results show significant divergence from previous studies, which reported that the tropospheric condition over Lagos (Geo. 6 . 5 °N, 3 . 3 °E), Nigeria, is predominantly super-refractive.

  11. Evaluating the cancer detection and grading potential of prostatic-zinc imaging: a simulation study

    International Nuclear Information System (INIS)

    Cortesi, M; Chechik, R; Breskin, A; Vartsky, D; Ramon, J; Raviv, G; Volkov, A; Fridman, E

    2009-01-01

    The present work deals with the analysis of prostatic-zinc-concentration images. The goal is to evaluate potential clinically relevant information that can be extracted from such images. In the absence of experimental images, synthetic ones are produced from clinically measured zinc-concentration distributions in certified benign and cancerous tissue samples, classified by the lesion grade. We describe the method for producing the images and model the effect of counting statistics noise. We present in detail the image analysis, which is based on a combination of standard image processing and segmentation tools, optimized for this particular application. The information on lowest zinc value obtained from the image analysis is translated to clinical data such as tumour presence, location, size and grade. Their confidence is evaluated with the help of standard statistical tools such as receiver operating characteristic analysis. The present work predicts a potential for detecting small prostate-cancer lesions, of grade (4+3) and above, with very good specificity and sensitivity. The present analysis further provides data on the pixel size and image counting statistics requested from the trans-rectal probe that will record in vivo prostatic-zinc maps in patients.

  12. Studies of radioimmunoassay for plasma aldosterone concentration by immunologic purification and extraction procedure without chromatography

    International Nuclear Information System (INIS)

    Yokoyama, Hisamitsu

    1975-01-01

    After the aldosterone fraction of plasma was specifically absorbed using highly concentrated anti-aldosterone serum(i.e. Ab-II; diluted to 1:50,000), it was applied to the radioimmunoassay: and the separation of the free from the bound fractions was performed by the saturated ammonium sulfate method. Reasonable and satisfactory standard curves were obtained, but attention should be given to environmental factors at measurement, especially to the room temperature in summer. According to our results the mean final recovery for 58 specimens was 41.8+-6.4(SD)% through the overall extraction procedure, and the minimum detectable sensitivity of the standard curve was 10pg. The mean water blank value was 7.02+-2.62 (SD) pg/tube. Possible reasons for the higher blank value than others may have been the reagent or the solvent blank, and/or the insufficient process of immunologic purification by Ad-II for the tritium-labelled aldosterone which was used for recovery and immunoassay. The precision was from 9.4 to 25.3% coefficient of variations; the accuracy and recovery rate were almost satisfactory. In our clinical application, the plasma aldosterone concentration indicated high values in the peripheral and affected adrenal venous blood of patients with primary aldosteronism. In a patient with Bartter's syndrome, hyperreninemia and secondary hyperaldosteronism were observed. Almost all of the patients with Addison's disease and with total adrenalectomy indicated the lowest or undetectable levels. A high level of plasma aldosterone concentration was measured in a patient with edema and chronic renal failure and one with juvenile hypertension associated with an orbital tumor. (JPN)

  13. Studies of radioimmunoassay for plasma aldosterone concentration by immunologic purification and extraction procedure without chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, H [Okayama Univ. (Japan). School of Medicine

    1975-07-01

    After the aldosterone fraction of plasma was specifically absorbed using highly concentrated anti-aldosterone serum(i.e. Ab-II; diluted to 1:50,000), it was applied to the radioimmunoassay: and the separation of the free from the bound fractions was performed by the saturated ammonium sulfate method. Reasonable and satisfactory standard curves were obtained, but attention should be given to environmental factors at measurement, especially to the room temperature in summer. According to our results the mean final recovery for 58 specimens was 41.8+-6.4(SD)% through the overall extraction procedure, and the minimum detectable sensitivity of the standard curve was 10pg. The mean water blank value was 7.02+-2.62 (SD) pg/tube. Possible reasons for the higher blank value than others may have been the reagent or the solvent blank, and/or the insufficient process of immunologic purification by Ad-II for the tritium-labelled aldosterone which was used for recovery and immunoassay. The precision was from 9.4 to 25.3% coefficient of variations; the accuracy and recovery rate were almost satisfactory. In our clinical application, the plasma aldosterone concentration indicated high values in the peripheral and affected adrenal venous blood of patients with primary aldosteronism. In a patient with Bartter's syndrome, hyperreninemia and secondary hyperaldosteronism were observed. Almost all of the patients with Addison's disease and with total adrenalectomy indicated the lowest or undetectable levels. A high level of plasma aldosterone concentration was measured in a patient with edema and chronic renal failure and one with juvenile hypertension associated with an orbital tumor.

  14. Development of a rapid HRM genotyping method for detection of dog-derived Giardia lamblia.

    Science.gov (United States)

    Tan, Liping; Yu, Xingang; Abdullahi, Auwalu Yusuf; Wu, Sheng; Zheng, Guochao; Hu, Wei; Song, Meiran; Wang, Zhen; Jiang, Biao; Li, Guoqing

    2015-11-01

    Giardia lamblia is a zoonotic flagellate protozoan in the intestine of human and many mammals including dogs. To assess a threat of dog-derived G. lamblia to humans, the common dog-derived G. lamblia assemblages A, C, and D were genotyped by high-resolution melting (HRM) technology. According to β-giardin gene sequence, the qPCR-HRM primers BG5 and BG7 were designed. A series of experiments on the stability, sensitivity, and accuracy of the HRM method were also tested. Results showed that the primers BG5 and BG7 could distinguish among three assemblages A, C, and D, which Tm value differences were about 1 °C to each other. The melting curves of intra-assay reproducibility were almost coincided, and those of inter-assay reproducibility were much the same shape. The lowest detection concentration was about 5 × 10(-6)-ng/μL sample. The genotyping results from 21 G. lamblia samples by the HRM method were in complete accordance with sequencing results. It is concluded that the HRM genotyping method is rapid, stable, specific, highly sensitive, and suitable for clinical detection and molecular epidemiological survey of dog-derived G. lamblia.

  15. Pathways of low carbon transition at the lowest cost. Pathways of low carbon transition in France at the lowest cost - Dynamics and average abatement costs (MACC)

    International Nuclear Information System (INIS)

    Perrissin Fabert, Baptiste; Foussard, Alexis

    2016-11-01

    The objective to divide greenhouse gas emissions in France by a factor four by 2050 implies the mobilisation at the lowest cost of the whole set of known sources of reduction of emissions in all economic sectors. In this context, this report is based on a methodology (D-CAM in French for dynamics - average abatement costs, MACC in English for Medium Abatement Cost Curves) which relies on a theoretical business-as-usual scenario, on a database on the potential, rate of development, and cost of mobilizable sources, and on a dynamic model of cost minimisation. The MACC tool is used to explore, for each sector, scenarios of de-carbonation which allow objectives of reduction of greenhouse gas emissions to be reached at different time horizons. An aggregated approach of this tool modifies the distribution of efforts of emission reduction between sectors with respect to a sector-based approach. Thus, a macro-assessment of low carbon transition does not reveal any obvious over-cost with respect to the business-as-usual scenario. A second document is a Power Point presentation which contains the same information, curves and graphs

  16. Heavy metal concentrations in the razor clams (Solen spp.) from Muara Tebas, Sarawak

    International Nuclear Information System (INIS)

    Devagi Kanakaraju; Connie Jios; Shabdin Mohd Long

    2008-01-01

    The razor clams (Solen spp) or locally known as ambal in Sarawak collected from Muara Tebas were studied for their heavy metals contents in tissues and shells. Sediment samples were also tested for their metal contents. Concentrations of Pb, Fe, Zn, Cu, Cd and Mn were determined by using Flame Atomic Absorption Spectrophotometer (FAAS). Tissues of razor clams showed highest concentrations of Fe and Zn, while shells accumulated highest concentrations of Pb and Mn. The lowest metal concentrations found were Cu and Cd. In general, the levels of metals in ambal were within the permissible limit recommended by international standard, the Food and Agricultural Organization (FAO). However, the study revealed that the sediments at Muara Tebas fall under the category of slightly polluted (for Pb) when compared to the guidelines suggested by United States Environment Protection Agency (USEPA). (author)

  17. Effects of ambient oxygen concentration on soot temperature and concentration for biodiesel and diesel spray combustion

    KAUST Repository

    Zhang, Ji

    2015-06-01

    Ambient oxygen concentration, a key variable directly related to exhaust gas recirculation (EGR) levels in diesel engines, plays a significant role in particulate matter (PM) and nitrogen oxides (NOx) emissions. The utilization of biodiesel in diesel engines has been investigated over the last decades for its renewable characteristics and lower emissions compared to diesel. In an earlier work, we demonstrated that the soot temperature and concentration of biodiesel were lower than diesel under regular diesel engine conditions without EGR. Soot concentration was quantified by a parameter called KL factor. As a continuous effort, this paper presents an experimental investigation of the ambient oxygen concentration on soot temperature and KL factor during biodiesel and diesel spray combustion. The experiment was implemented in a constant volume chamber system, where the ambient oxygen concentration varied from 21 to 10% and the ambient temperature was kept to 1,000 K. A high speed two-color pyrometry technique was used to measure transient soot temperature and the KL factor of the spray flame. The soot temperature of biodiesel is found to be lower than that of diesel under the same conditions, which follows the same trend from our previous results found when the ambient temperature changes to 21% oxygen conditions. A reduction in ambient oxygen concentration generally reduces the soot temperature for both fuels. However, this is a complicated effect on soot processes as the change of oxygen concentration greatly affects the balance between soot formation and oxidation. The KL factor is observed to be the highest at 12% O2 for diesel and 18% O2 for biodiesel, respectively. On the other hand, the 10% O2 condition shows the lowest KL factor for both fuels. These results can provide quantitative experimental evidences to optimize the ambient oxygen concentration for diesel engines using different fuels for better emissions characteristics. © 2014 American Society of

  18. Copper clean-up procedure for ultrasonic extraction and analysis of pyrethroid and phenylpyrazole pesticides in sediments by gas chromatography-electron capture detection

    Energy Technology Data Exchange (ETDEWEB)

    Wu Jun; Lin Youjian; Lu Jian; Wilson, Chris, E-mail: pcwilson@ufl.edu

    2011-08-15

    A rapid ultrasonic extraction method coupled with a heated-copper clean-up procedure for removing interfering constituents was developed for analyzing pyrethroid and phenylpyrazole pesticides in sediments. Incubation of the 60 mL extract with 12 g copper granules at 60 {sup o}C for 2 h was determined to be the optimal conditions for removing the interfering constituents. Eleven pyrethroid and phenylpyrazole pesticides were spiked into sediment samples to determine the effectiveness of the ultrasonic extraction method. The average recoveries of pyrethroids and phenylpyrazoles in sediment at 4 {sup o}C storage on day 0, 1, 7, 14, and 21 ranged from 98.6 to 120.0%, 79.2 to 116.0%, 85.0 to 119.7%, 93.6 to 118.7%, and 92.1 to 118.2%, respectively, with all percent relative standard deviations less than 10% (most < 6%). This illustrated the stability of pyrethroids and phenylpyrazoles in sediment during sediment aging at 4 {sup o}C. Recoveries of the pesticides ranged from 98.6% to 120.0% for lowest fortification level (2-16 {mu}g kg{sup -1}), from 97.8% to 117.9% for middle fortification level (10-80 {mu}g kg{sup -1}), and from 94.3% to 118.1% for highest fortification level (20-160 {mu}g kg{sup -1}). Relative standard deviations of pesticide recoveries were usually less than 7%. Method detection limits of target pesticides ranged from 0.22 {mu}g kg{sup -1} to 3.72 {mu}g kg{sup -1}. Furthermore, field sediment samples collected from four residential lakes during a three-month monitoring period were analyzed to evaluate the effectiveness of this method. Bifenthrin was detected in all of sediment samples (highest concentration 260.33 {+-} 41.71 {mu}g kg{sup -1}, lowest concentration 5.68 {+-} 0.38 {mu}g kg{sup -1}), and fipronil sulfone was detected at least once in sediment samples collected from three sites with concentrations ranging from 1.73 {+-} 0.53 to 7.53 {+-} 0.01 {mu}g kg{sup -1}. - Highlights: {yields} A rapid extraction and copper-based clean-up method was

  19. Airborne Measurements of CO2 Column Concentration and Range Using a Pulsed Direct-Detection IPDA Lidar

    Science.gov (United States)

    Abshire, James B.; Ramanathan, Anand; Riris, Haris; Mao, Jianping; Allan, Graham R.; Hasselbrack, William E.; Weaver, Clark J.; Browell, Edward V.

    2013-01-01

    We have previously demonstrated a pulsed direct detection IPDA lidar to measure range and the column concentration of atmospheric CO2. The lidar measures the atmospheric backscatter profiles and samples the shape of the 1,572.33 nm CO2 absorption line. We participated in the ASCENDS science flights on the NASA DC-8 aircraft during August 2011 and report here lidar measurements made on four flights over a variety of surface and cloud conditions near the US. These included over a stratus cloud deck over the Pacific Ocean, to a dry lake bed surrounded by mountains in Nevada, to a desert area with a coal-fired power plant, and from the Rocky Mountains to Iowa, with segments with both cumulus and cirrus clouds. Most flights were to altitudes >12 km and had 5-6 altitude steps. Analyses show the retrievals of lidar range, CO2 column absorption, and CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds, between cumulus clouds, and to stratus cloud tops. The retrievals shows the decrease in column CO2 due to growing vegetation when flying over Iowa cropland as well as a sudden increase in CO2 concentration near a coal-fired power plant. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption lineshape (averaged for 50 s) matched the predicted shapes to better than 1% RMS error. For 10 s averaging, the scatter in the retrievals was typically 2-3 ppm and was limited by the received signal photon count. Retrievals were made using atmospheric parameters from both an atmospheric model and from in situ temperature and pressure from the aircraft. The retrievals had no free parameters and did not use empirical adjustments, and >70% of the measurements passed screening and were used in analysis. The differences between the lidar-measured retrievals and in situ measured average CO2 column concentrations were 6 km.

  20. The effect of growing media and concentration of nutrient solution on growth, flowering and macroelement content of media and leaves of Tymophylla tenuiloba Small

    Directory of Open Access Journals (Sweden)

    Joanna Nowak

    2013-12-01

    Full Text Available Effects of growing media and concentration of nutrient solution on growth, flowering, evapotranspiration and macroelement content of media and leaves of Tymophylla tenuiloba were evaluated under ebb-and-flow conditions. Two media: peat and peat + perlite (3:l, v/v, and four concentrations of nutrient solution: 1.0, 1.5, 2.0, 2.5 mS cm-1 were applied. High quality plants were produced in both media and all concentration of nutrient solution. The lowest evapotranspiration was measured at the highest concentration of nutrient solution. N concentration of leaves was high in all treatments. Concentrations of K, Ca, and Mg decreased with increasing concentration of nutrient solution. Opposite was found for P. At the end of cultivation the lowest pH was measured in the upper layer of growing media. The highest total soluble salt level was measured in the upper layers. Upper layers accumulated more N-NO3, P, Ca, and Mg. Mineral element content of both media was high in all concentrations of nutrient solution. Low concentration of nutrient solution at 1.0 mS cm-1 is recommended, although -1Tymophylla tenuiloba-1 can be also cultivated at higher concentrations of nutrient solution up to 2.5mS cm-1, if placed on the same bench with other bedding plants requiring more nutrients.

  1. Application of PIGE to determine fluorine concentration in human teeth. Contribution to fluorosis study

    International Nuclear Information System (INIS)

    Salah, H.; Arab, N.

    2007-01-01

    Fluorosis, osteoselerosis, and systemic illness may result when tolerance levels of fluorine intake are exceeded. To avoid these abnormalities, we shall be aware of the mechanisms of their development. For this, quantitative results gathered from different parts of the world are necessary. In this paper, PIGE method is used to determine fluorine concentration in human teeth, collected from different regions of the Algerian Sahara. Both enamel and dentine regions were inspected. The external and internal mappings of the analyzed teeth have shown more variation in the localized fluorine concentration in dentine than in enamel, and the lowest level of fluorine concentration was observed in the frontier crown-root zone. The obtained results reveal relatively high fluorine concentration lying within the limit of fluorosis, according to the standardised grading dental fluorosis. (author)

  2. Temporal variations of methane concentration and isotopic composition in groundwater of the St. Lawrence Lowlands, eastern Canada

    Science.gov (United States)

    Rivard, Christine; Bordeleau, Geneviève; Lavoie, Denis; Lefebvre, René; Malet, Xavier

    2018-03-01

    Dissolved methane concentrations in shallow groundwater are known to vary both spatially and temporally. The extent of these variations is poorly documented although this knowledge is critical for distinguishing natural fluctuations from anthropogenic impacts stemming from oil and gas activities. This issue was addressed as part of a groundwater research project aiming to assess the risk of shale gas development for groundwater quality over a 500-km2 area in the St. Lawrence Lowlands (Quebec, Canada). A specific study was carried out to define the natural variability of methane concentrations and carbon and hydrogen isotope ratios in groundwater, as dissolved methane is naturally ubiquitous in aquifers of this area. Monitoring was carried out over a period of up to 2.5 years in seven monitoring wells. Results showed that for a given well, using the same sampling depth and technique, methane concentrations can vary over time from 2.5 to 6 times relative to the lowest recorded value. Methane isotopic composition, which is a useful tool to distinguish gas origin, was found to be stable for most wells, but varied significantly over time in the two wells where methane concentrations are the lowest. The use of concentration ratios, as well as isotopic composition of methane and dissolved inorganic carbon (DIC), helped unravel the processes responsible for these variations. This study indicates that both methane concentrations and isotopic composition, as well as DIC isotopes, should be regularly monitored over at least 1 year to establish their potential natural variations prior to hydrocarbon development.

  3. Uric acid detection using uv-vis spectrometer

    Science.gov (United States)

    Norazmi, N.; Rasad, Z. R. Abdul; Mohamad, M.; Manap, H.

    2017-10-01

    The aim of this research is to detect uric acid (UA) concentration using Ultraviolet-Visible (UV-Vis) spectrometer in the Ultraviolet (UV) region. Absorption technique was proposed to detect different uric acid concentrations and its UV absorption wavelength. Current practices commonly take a lot of times or require complicated structures for the detection process. By this proposed spectroscopic technique, every concentration can be detected and interpreted into an absorbance value at a constant wavelength peak in the UV region. This is due to the chemical characteristics belong to the uric acid since it has a particular absorption cross-section, σ which can be calculated using Beer’s Lambert law formula. The detection performance was displayed using Spectrasuite sofware. It showed fast time response about 3 seconds. The experiment proved that the concentrations of uric acid were successfully detected using UV-Vis spectrometer at a constant absorption UV wavelength, 294.46 nm in a low time response. Even by an artificial sample of uric acid, it successfully displayed a close value as the ones reported with the use of the medical sample. It is applicable in the medical field and can be implemented in the future for earlier detection of abnormal concentration of uric acid.

  4. Analysis of glycoprotein-derived oligosaccharides in glycoproteins detected on two-dimensional gel by capillary electrophoresis using on-line concentration method.

    Science.gov (United States)

    Kamoda, Satoru; Nakanishi, Yasuharu; Kinoshita, Mitsuhiro; Ishikawa, Rika; Kakehi, Kazuaki

    2006-02-17

    Capillary electrophoresis (CE) is an effective tool to analyze carbohydrate mixture derived from glycoproteins with high resolution. However, CE has a disadvantage that a few nanoliters of a sample solution are injected to a narrow capillary. Therefore, we have to prepare a sample solution of high concentration for CE analysis. In the present study, we applied head column field-amplified sample stacking method to the analysis of N-linked oligosaccharides derived from glycoprotein separated by two-dimensional gel electrophoresis. Model studies demonstrated that we achieved 60-360 times concentration effect on the analysis of carbohydrate chains labeled with 3-aminobenzoic acid (3-AA). The method was applied to the analysis of N-linked oligosaccharides from glycoproteins separated and detected on PAGE gel. Heterogeneity of alpha1-acid glycoprotein (AGP), i.e. glycoforms, was examined by 2D-PAGE and N-linked oligosaccharides were released by in-gel digestion with PNGase F. The released oligosaccharides were derivatized with 3-AA and analyzed by CE. The results showed that glycoforms having lower pI values contained a larger amount of tetra- and tri-antennary oligosaccharides. In contrast, glycoforms having higher pI values contained bi-antennary oligosaccharides abundantly. The result clearly indicated that the spot of a glycoprotein glycoform detected by Coomassie brilliant blue staining on 2D-PAGE gel is sufficient for quantitative profiling of oligosaccharides.

  5. Rapid colorimetric sensing platform for the detection of Listeria monocytogenes foodborne pathogen.

    Science.gov (United States)

    Alhogail, Sahar; Suaifan, Ghadeer A R Y; Zourob, Mohammed

    2016-12-15

    Listeria monocytogenes is a serious cause of human foodborne infections worldwide, which needs spending billions of dollars for inspection of bacterial contamination in food every year. Therefore, there is an urgent need for rapid, in-field and cost effective detection techniques. In this study, rapid, low-cost and simple colorimetric assay was developed using magnetic nanoparticles for the detection of listeria bacteria. The protease from the listeria bacteria was detected using D-amino acid substrate. D-amino acid substrate was linked to the carboxylic acid on the magnetic nanoparticles using EDC/NHS chemistry. The cysteine residue at the C-terminal of the substrate was used for the self-assembled monolayer formation on the gold sensor surface, which in turn the black magnetic nanobeads will mask the golden color. The color will change from black to golden color upon the cleavage of the specific peptide sequence by the Listeria protease. The sensor was tested with serial dilutions of Listeria bacteria. It was found that the appearance of the gold surface area is proportional to the bacterial concentrations in CFU/ml. The lowest detection limit of the developed sensor for Listeria was found to be 2.17×10(2) colony forming unit/ml (CFU/ml). The specificity of the biosensor was tested against four different foodborne associated bacteria (Escherichia coli, Salmonella, Shigella flexnerii and Staphylococcus aureus). Finally, the sensor was tested with artificially spiked whole milk and ground meat spiked with listeria. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Dietary fish oil alters the lysophospholipid metabolomic profile and decreases urinary 11-dehydro thromboxane B₂ concentration in healthy Beagles.

    Science.gov (United States)

    Hall, Jean A; Brockman, Jeffrey A; Jewell, Dennis E

    2011-12-15

    Increased concentrations of dietary fish oil and antioxidants have been shown previously to change circulating concentrations of individual fatty acids (FAs) and vitamin E. The purpose of this study was to further investigate the effects of vitamins E and C, in combination with dietary fish oil, on selected blood and urinary biomarkers. Fifty adult Beagle dogs (mean age 5.3 years, range 1.4-14.2 years) were randomized into five dietary treatment groups for 90 days. All foods were complete and balanced and met the nutrient profiles of AAFCO for adult dogs. For 60 days before study initiation, dogs consumed a pretrial food that contained 74 IU/kg vitaminE and 0mg/kg vitaminC. The five experimental foods were confirmed by analytical methods to contain ≥ 640 IU/kg vitaminE and 130 mg/kg vitaminC (as fed). Experimental foods ranged from low levels of EPA and DHA (pretrial food and lowest experimental food had 0.01% EPA and no detectable DHA) to the highest experimental food with 0.25% EPA and 0.17% DHA. Serum was analyzed for FAs, vitamin E, and cholesterol concentrations; urine was analyzed for 11-dehydro thromboxane B(2) (TXB(2)). Serum was also used for metabolomic analysis. FA intake ranged from 0.02 g/day EPA and 0.02 g/day DHA to 0.58 g/day EPA and 0.39 g/day DHA. Increasing dietary concentrations of EPA and DHA resulted in increased serum concentrations of EPA and DHA in a dose-dependent fashion. Greater dietary vitamin E intake resulted in increased serum vitamin E concentrations (Pvitamin E concentrations (Pvitamin E concentration is enhanced primarily by feeding vitamin E and secondarily by serum cholesterol concentration. When feeding diets enriched with fish oil, the major negative predictor of urinary 11-dehydro TXB(2) concentration is serum EPA concentration. Plasma lysophospholipids can be dynamically regulated by dietary fish oil supplementation. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Evaluation of dissolved oxygen and organic substances concentrations in water of the nature reserve Alluvium Zitavy

    International Nuclear Information System (INIS)

    Palaticka, A.; Noskovic, J.; Babosova, M.

    2007-01-01

    In 2006 concentrations of dissolved oxygen and organic substances were evaluated in water in the Nature Reserve Alluvium Zitavy (indirect method based on their oxidation by K 2 Cr 2 0 7 was used). The results are represented in mg of O 2 · dm -3 . Taking of samples took place in 6 sampling sites in regular month intervals. Based on obtained data and according to the standard STN 75 7221 (Water quality -The classification of the water surface quality) water in individual sampling sites was ranked into the classes of the .water surface quality. From the data it is clear that the concentrations of dissolved oxygen and organic substances in the Nature Reserve Alluvium Zitavy changed in dependence on sampling sites and time. The highest mean concentrations of dissolved oxygen in dependence on sampling time were found out in spring months and the lowest concentrations in summer months. They ranged from 1.6 mg 0 2 · dm -3 (July) to 9.0 mg O 2 · dm -3 (March). Falling dissolved oxygen values can be related to successive increase of water temperature, thus good conditions were created for decomposition of organic matter by microorganisms in water and sediments in which they use dissolved oxygen. In dependence on sampling place the highest mean concentration of dissolved oxygen was in sampling site No. 4 (6.0 mg 0 2 · dm -3 ) which is situated in the narrowest place in the NR. The lowest value was in sampling site No. 2 (3.6 mg 0 2 · dm -3 ) which is a typical wetland ecosystem. High mean values of COD Cr in dependence on sampling time were determined in summer months and low values during winter moths. Dependence of COD Cr values on sampling site was also manifested. The lowest mean value was obtained in sampling site No. 4 (59.5 mg · dm -3 ) and the highest value in sampling site No. 5 (97.1 mg · dm -3 ) which is also a typical wetland. Based on the results and according to the STN 75 7221 we ranked water in all sampling sites into the 5 th class of the water

  8. Bioaccumulation of heavy metals in fish (tilapia zilli and clarias gariepinus) organs from river Benue, North - Central Nigeria

    International Nuclear Information System (INIS)

    Eneji, I.S.; Ato, R.S.; Annune, P.A.

    2011-01-01

    Heavy metals concentrations were determined in fish organs of Tilapia zilli and Clarias gariepinus from River Benue along Makurdi metropolis sing atomic absorption spectrophotometer. The results indicated that Tilapia zilli gills contained the highest concentration (52.2%) of all the detected heavy metals, followed by the intestine (26.3%), while the muscle tissues appeared to be the least preferred site for the bioaccumulation of metals as the lowest metal concentration (21.5%) were detected in this tissue. Similarly, the Clarias gariepinus gills contained the highest concentration (40.3%) of all the detected heavy metals, followed by the intestine (31.6%), while the muscle tissue (28.1%) was the lowest. The trend of heavy metals concentration can be represented as: Cr > Zn > Cu > Fe > Mn > Cd > Pb for Tilapia zilli, while that of Clarias gariepinus was Cr > Zn > Fe > Cu > Mn > Cd > Pb. Tilapia zilli showed high bioaccumulation factors of 244, 229 and 178 for Cr, Zn and Cu, respectively. Claria gariepinus showed 232, 226 and 151 for Cr, Zn and Fe, respectively. This suggests that the fish samples could be used to monitor Cr and Zn pollution levels in the River Benue. (author)

  9. Fluorescence spectroscopy of Rhodamine 6G: concentration and solvent effects.

    Science.gov (United States)

    Zehentbauer, Florian M; Moretto, Claudia; Stephen, Ryan; Thevar, Thangavel; Gilchrist, John R; Pokrajac, Dubravka; Richard, Katherine L; Kiefer, Johannes

    2014-01-01

    Rhodamine 6G (R6G), also known as Rhodamine 590, is one of the most frequently used dyes for application in dye lasers and as a fluorescence tracer, e.g., in the area of environmental hydraulics. Knowing the spectroscopic characteristics of the optical emission is key to obtaining high conversion efficiency and measurement accuracy, respectively. In this work, solvent and concentration effects are studied. A series of eight different organic solvents (methanol, ethanol, n-propanol, iso-propanol, n-butanol, n-pentanol, acetone, and dimethyl sulfoxide (DMSO)) are investigated at constant dye concentration. Relatively small changes of the fluorescence spectrum are observed for the different solvents; the highest fluorescence intensity is observed for methanol and lowest for DMSO. The shortest peak wavelength is found in methanol (568 nm) and the longest in DMSO (579 nm). Concentration effects in aqueous R6G solutions are studied over the full concentration range from the solubility limit to highly dilute states. Changing the dye concentration provides tunability between ∼550 nm in the dilute case and ∼620 nm at high concentration, at which point the fluorescence spectrum indicates the formation of R6G aggregates. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Culture growth of testate amoebae under different silicon concentrations.

    Science.gov (United States)

    Wanner, Manfred; Seidl-Lampa, Barbara; Höhn, Axel; Puppe, Daniel; Meisterfeld, Ralf; Sommer, Michael

    2016-10-01

    Testate amoebae with self-secreted siliceous shell platelets ("idiosomes") play an important role in terrestrial silicon (Si) cycles. In this context, Si-dependent culture growth dynamics of idiosomic testate amoebae are of interest. Clonal cultures of idiosomic testate amoebae were analyzed under three different Si concentrations: low (50μmolL -1 ), moderate/site-specific (150μmolL -1 ) and high Si supply (500μmolL -1 ). Food (Saccharomyces cerevisiae) was provided in surplus. (i) Shell size of four different clones of idiosomic testate amoebae either decreased (Trinema galeata, Euglypha filifera cf.), increased (E. rotunda cf.), or did not change (E. rotunda) under the lowest Si concentration (50μmolSiL -1 ). (ii) Culture growth of idiosomic Euglypha rotunda was dependent on Si concentration. The more Si available in the culture medium, the earlier the entry into exponential growth phase. (iii) Culture growth of idiosomic Euglypha rotunda was dependent on origin of inoculum. Amoebae previously cultured under a moderate Si concentration revealed highest sustainability in consecutive cultures. Amoebae derived from cultures with high Si concentrations showed rapid culture growth which finished early in consecutive cultures. (iv) Si (diluted in the culture medium) was absorbed by amoebae and fixed in the amoeba shells resulting in decreased Si concentrations. Copyright © 2016 Elsevier GmbH. All rights reserved.

  11. Correction factor to determine total hydrogen+deuterium concentration obtained by inert gas fusion-thermal conductivity detection (IGF- TCD) technique

    International Nuclear Information System (INIS)

    Ramakumar, K.L.; Sesha Sayi, Y.; Shankaran, P.S.; Chhapru, G.C; Yadav, C.S.; Venugopal, V.

    2004-01-01

    The limitation of commercially available dedicated equipment based on Inert Gas Fusion- Thermal Conductivity Detection (IGF - TCD) for the determination of hydrogen+deuterium is described. For a given molar concentration, deuterium is underestimated vis a vis hydrogen because of lower thermal conductivity and not considering its molecular weight in calculations. An empirical correction factor based on the differences between the thermal conductivities of hydrogen, deuterium and the carrier gas argon, and the mole fraction of deuterium in the sample has been derived to correct the observed hydrogen+deuterium concentration. The corrected results obtained by IGF - TCD technique have been validated by determining hydrogen and deuterium contents in a few samples using an independent method based on hot vacuum extraction-quadrupole mass spectrometry (HVE-QMS). Knowledge of mole fraction of deuterium (XD) is necessary to effect the correction. The correction becomes insignificant at low X D values (XD < 0.2) as the precision in the IGF measurements is comparable with the extent of correction. (author)

  12. Influence of land cover on riverine dissolved organic carbon concentrations and export in the Three Rivers Headwater Region of the Qinghai-Tibetan Plateau.

    Science.gov (United States)

    Ma, Xiaoliang; Liu, Guimin; Wu, Xiaodong; Smoak, Joseph M; Ye, Linlin; Xu, Haiyan; Zhao, Lin; Ding, Yongjian

    2018-07-15

    The Qinghai-Tibetan plateau (QTP) stores a large amount of soil organic carbon and is the headwater region for several large rivers in Asia. Therefore, it is important to understand the influence of environmental factors on river water quality and the dissolved organic carbon (DOC) export in this region. We examined the water physico-chemical characteristics, DOC concentrations and export rates of 7 rivers under typical land cover types in the Three Rivers Headwater Region during August 2016. The results showed that the highest DOC concentrations were recorded in the rivers within the catchment of alpine wet meadow and meadow. These same rivers had the lowest total suspended solids (TSS) concentrations. The rivers within steppe and desert had the lowest DOC concentrations and highest TSS concentrations. The discharge rates and catchment areas were negatively correlated with DOC concentrations. The SUVA 254 values were significantly negatively correlated with DOC concentrations. The results suggest that the vegetation degradation, which may represent permafrost degradation, can lead to a decrease in DOC concentration, but increasing DOC export and soil erosion. In addition, some of the exported DOC will rapidly decompose in the river, and therefore affect the regional carbon cycle, as well as the water quality in the source water of many large Asian rivers. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Serum vitamin E concentrations among highly functioning hip fracture patients are higher than in nonfracture controls.

    Science.gov (United States)

    D'Adamo, Christopher R; Shardell, Michelle D; Hicks, Gregory E; Orwig, Denise L; Hochberg, Marc C; Semba, Richard D; Yu-Yahiro, Janet A; Ferrucci, Luigi; Magaziner, Jay S; Miller, Ram R

    2011-03-01

    Malnutrition after hip fracture is common and associated with poor outcomes and protracted recovery. Low concentrations of vitamin E have been associated with incident decline in physical function among older adults and may, therefore, be particularly important to functionally compromised patients hip fracture patients. Serum concentrations of α-tocopherol and γ-tocopherol, the 2 major forms of vitamin E, were assessed in 148 female hip fracture patients 65 years or older from the Baltimore Hip Studies cohort 4 around the time of fracture (baseline) and at 2, 6, and 12 month postfracture follow-up visits (recovery). It was hypothesized that mean concentrations of both forms of vitamin E among these hip fracture patients would be lowest at the baseline visit and increase at each study visit during the year after fracture. Linear regression and generalized estimating equations were used to assess changes in vitamin E concentrations after adjustment for covariates and to determine predictors of vitamin E concentrations at baseline and throughout recovery. It was also hypothesized that vitamin E concentrations shortly after hip fracture would be lower than those in nonfracture controls after adjustment for covariates. To evaluate this hypothesis, linear regression was used to perform adjusted comparisons of baseline vitamin E concentrations among Baltimore Hip Studies cohort 4 participants to 1076 older women without history of hip fracture from the Women's Health and Aging Study I, Invecchiare in Chianti Study, and the National Health and Nutrition Examination Surveys. Mean α-tocopherol was lowest at baseline, and time from fracture to blood draw was positively associated with baseline α-tocopherol (P = .005). Mean γ-tocopherol did not change appreciably throughout the year after fracture, although it fluctuated widely within individuals. Serum concentrations of α-tocopherol and γ-tocopherol were highest among the hip fracture population after adjustment (P hip

  14. ON THE BINARY FREQUENCY OF THE LOWEST MASS MEMBERS OF THE PLEIADES WITH HUBBLE SPACE TELESCOPE WIDE FIELD CAMERA 3

    International Nuclear Information System (INIS)

    Garcia, E. V.; Dupuy, Trent J.; Allers, Katelyn N.; Liu, Michael C.; Deacon, Niall R.

    2015-01-01

    We present the results of a Hubble Space Telescope Wide Field Camera 3 (WFC3) imaging survey of 11 of the lowest mass brown dwarfs in the Pleiades known (25–40 M Jup ). These objects represent the predecessors to T dwarfs in the field. Using a semi-empirical binary point-spread function (PSF)-fitting technique, we are able to probe to 0.″ 03 (0.75 pixel), better than 2x the WFC3/UVIS diffraction limit. We did not find any companions to our targets. From extensive testing of our PSF-fitting method on simulated binaries, we compute detection limits which rule out companions to our targets with mass ratios of ≳0.7 and separations ≳4 AU. Thus, our survey is the first to attain the high angular resolution needed to resolve brown dwarf binaries in the Pleiades at separations that are most common in the field population. We constrain the binary frequency over this range of separation and mass ratio of 25–40 M Jup Pleiades brown dwarfs to be <11% for 1σ (<26% at 2σ). This binary frequency is consistent with both younger and older brown dwarfs in this mass range

  15. Effect of Crack Tip Stress Concentration Factor on Fracture Resistance in Vacuum Environment

    Science.gov (United States)

    2015-01-20

    indicate: (1) in all alloys, the fracture resistance is highest for blunt-notches (smaller Kt), and is lowest for fatigue -sharpened precracked...paths are transgranular and the fracture mode is ductile void coalescence in all cases, irrespective of the stress concentration factor. 20-01-2015...because of corrosion and/or various loading conditions such as fatigue , fretting, abrasion, etc. Also, the geometry of the structure may cause an

  16. A magnetic bead-based method for concentrating DNA from human urine for downstream detection.

    Directory of Open Access Journals (Sweden)

    Hali Bordelon

    Full Text Available Due to the presence of PCR inhibitors, PCR cannot be used directly on most clinical samples, including human urine, without pre-treatment. A magnetic bead-based strategy is one potential method to collect biomarkers from urine samples and separate the biomarkers from PCR inhibitors. In this report, a 1 mL urine sample was mixed within the bulb of a transfer pipette containing lyophilized nucleic acid-silica adsorption buffer and silica-coated magnetic beads. After mixing, the sample was transferred from the pipette bulb to a small diameter tube, and captured biomarkers were concentrated using magnetic entrainment of beads through pre-arrayed wash solutions separated by small air gaps. Feasibility was tested using synthetic segments of the 140 bp tuberculosis IS6110 DNA sequence spiked into pooled human urine samples. DNA recovery was evaluated by qPCR. Despite the presence of spiked DNA, no DNA was detectable in unextracted urine samples, presumably due to the presence of PCR inhibitors. However, following extraction with the magnetic bead-based method, we found that ∼50% of spiked TB DNA was recovered from human urine containing roughly 5×10(3 to 5×10(8 copies of IS6110 DNA. In addition, the DNA was concentrated approximately ten-fold into water. The final concentration of DNA in the eluate was 5×10(6, 14×10(6, and 8×10(6 copies/µL for 1, 3, and 5 mL urine samples, respectively. Lyophilized and freshly prepared reagents within the transfer pipette produced similar results, suggesting that long-term storage without refrigeration is possible. DNA recovery increased with the length of the spiked DNA segments from 10±0.9% for a 75 bp DNA sequence to 42±4% for a 100 bp segment and 58±9% for a 140 bp segment. The estimated LOD was 77 copies of DNA/µL of urine. The strategy presented here provides a simple means to achieve high nucleic acid recovery from easily obtained urine samples, which does not contain inhibitors of PCR.

  17. Automatic detection of arterial input function in dynamic contrast enhanced MRI based on affinity propagation clustering.

    Science.gov (United States)

    Shi, Lin; Wang, Defeng; Liu, Wen; Fang, Kui; Wang, Yi-Xiang J; Huang, Wenhua; King, Ann D; Heng, Pheng Ann; Ahuja, Anil T

    2014-05-01

    To automatically and robustly detect the arterial input function (AIF) with high detection accuracy and low computational cost in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In this study, we developed an automatic AIF detection method using an accelerated version (Fast-AP) of affinity propagation (AP) clustering. The validity of this Fast-AP-based method was proved on two DCE-MRI datasets, i.e., rat kidney and human head and neck. The detailed AIF detection performance of this proposed method was assessed in comparison with other clustering-based methods, namely original AP and K-means, as well as the manual AIF detection method. Both the automatic AP- and Fast-AP-based methods achieved satisfactory AIF detection accuracy, but the computational cost of Fast-AP could be reduced by 64.37-92.10% on rat dataset and 73.18-90.18% on human dataset compared with the cost of AP. The K-means yielded the lowest computational cost, but resulted in the lowest AIF detection accuracy. The experimental results demonstrated that both the AP- and Fast-AP-based methods were insensitive to the initialization of cluster centers, and had superior robustness compared with K-means method. The Fast-AP-based method enables automatic AIF detection with high accuracy and efficiency. Copyright © 2013 Wiley Periodicals, Inc.

  18. Portable devices for monitoring radon and its progeny in air

    International Nuclear Information System (INIS)

    Zhang Huaiqin; Yao Wanyuan; Su Jingling; Liu Jinhua

    1990-01-01

    We have developed two kinds of portable monitoring devices to measure the concentration and potential energy concentration of radon and its progeny in air. The thermoluminescence material CaSO4 (Tm) is used as the detection element. One of the devices is called passive radon monitor. The lowest detectable limit for radon in air is about 1.5 Bq/m 3 , as a sampling time being one week. Good reliability and ease to operate are its main advantages. The second kind of device is called a working level monitor which consists of a miniature remembrane pump and an integrating sampling probe. The lowest detectable limit is about 0.00043 WL (9x10 -9 J/m 3 ) for a sampling time of 6 hours. It weighs only 0.35 kg, but maintenance is necessary sometimes. (author). 6 refs, 2 figs, 4 tabs

  19. Bioaerosol collection and concentration for microseparations-based detectors.

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, Eric B. (Sandia National Laboratories, Livermore, CA); Ellis, C. R. Bowe (Sandia National Laboratories, Livermore, CA); Kanouff, Michael P. (Sandia National Laboratories, Livermore, CA); Rader, Daniel John; Wally, Karl (Sandia National Laboratories, Livermore, CA)

    2005-03-01

    The ability to detect Weapons of Mass Destruction biological agents rapidly and sensitively is vital to homeland security, spurring development of compact detection systems at Sandia and elsewhere. One such system is Sandia's microseparations-based pChemLab. Many bio-agents are serious health threats even at extremely low concentrations. Therefore, a universal challenge for detection systems is the efficient collection and selective transport of highly diffuse bio-agents against the enormous background of benign particles and species ever present in the ambient environment. We have investigated development of a ''front end'' system for the collection, preconcentration, and selective transport of aerosolized biological agents from dilute (1-10 active particles per liter of air) atmospheric samples, to ultimate concentrations of {approx}20 active particles per microliter of liquid, for interface with microfluidic-based analyses and detection systems. Our approach employs a Sandia-developed aerosol particle-focusing microseparator array to focus size-selected particles into a mating microimpinger array of open microfluidic transport channels. Upon collection (i.e., impingement, submergence, and liquid suspension), microfluidic dielectrophoretic particle concentrators and sorters can be employed to further concentrate and selectively transport bio-agent particles to the sample preparation stages of microfluidic analyses and detection systems. This report documents results in experimental testing, modeling and analysis, component design, and materials fabrication critical to establishing proof-of-principle for this collection ''front end''. Outstanding results have been achieved for the aerodynamic microseparator, and for the post-collection dielectrophoretic concentrator and sorter. Results have been obtained for the microimpinger, too, but issues of particle-trapping by surface tension in liquid surfaces have proven

  20. Reflective measurement of water concentration using millimeter wave illumination

    Science.gov (United States)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  1. Colloid Detection in Natural Ground Water from Ruprechtov by Laser-Induced Breakdown Detection

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, W.; Geckeis, H.; Goetz, R. [FZK - Inst. fuer Nukleare Entsorgung, Ka rlsruhe (Germany)]. e-mail: hauser@ine.fzk.de; Noseck, U. [Gesellschaft fuer Anlagen- und Reaktorsicherheit, D-38122 Braunschweig (Germany); Laciok, A. [Nuclear Research Inst. Rez plc, Waste and Environmental Management Dept., Husinec-Rez, PSC 250 68 (Czech Republic)

    2007-06-15

    A borehole ground water sampling system and a mobile laser-induced breakdown detection (LIBD) equipment for colloid detection combined with a geomonitoring unit have been applied to characterize the natural background colloid concentration in ground waters of the Ruprechtov natural analogue site (Czech Republic). Ground water has been sampled using steel cylinders. To minimize artifacts during ground water sampling the contact to atmospheric oxygen has been excluded. The ground water samples collected in this way are transported to the laboratory where they have been connected to a series of flow-through detection cells. Argon gas is used to press the ground water through these detection cells for colloid analysis (LIBD), pH, Eh, electrical conductivity and oxygen content. After the above mentioned analysis additional samples are taken for chemical analysis by ICP-AES, ICP-MS, IC- and DOC-detection. Our data obtained by in-situ- and laboratory- measurements point out that the natural colloid concentration found at the Ruprechtov site is a strong function of the ground water ionic strength. The LIBD determined natural background colloid concentrations found at Ruprechtov are compared with data of studies performed in Aespoe (Sweden) and Grimsel (Switzerland)

  2. Motivated for Leisure in the Future: A Person-Centred Longitudinal Study in the Lowest Level of Secondary Education

    Science.gov (United States)

    Van der Veen, Ineke; Peetsma, Thea

    2011-01-01

    Long-term future time perspective on leisure has been found to relate negatively to school effort. This was studied further by recognizing types of students based on developments in long-term leisure perspectives and comparing their development in motivation and academic achievement. Around 1200 12-13 year old students attending the lowest level…

  3. Heavy metals detection using biosensor cells of a novel marine luminescent bacterium Vibrio sp. MM1 isolated from the Caspian Sea.

    Science.gov (United States)

    Mohseni, Mojtaba; Abbaszadeh, Jaber; Maghool, Shima-Sadat; Chaichi, Mohammad-Javad

    2018-02-01

    Monitoring and assessing toxic materials which are being released into the environment along with wastewater is a growing concern in many industries. The current research describes a highly sensitive and rapid method for the detection of toxic concentrations of heavy metals in aquatic environments. Water samples were collected from southern coasts of the Caspian Sea followed by screening of luminescent bacteria. Phylogenetic analysis, including gene sequence of 16S rRNA, and biochemical tests were performed for identification of the isolate. Luminescence activity was tested and measured after treatment of the isolate with different concentrations of heavy metals and reported as EC 50 value for each metal. A luminous, gram negative bacterium with the shape of a curved rod was isolated from the Caspian Sea. Biochemical tests and 16S rRNA gene sequence analysis indicated that the isolate MM1 had more than 99% similarity to Vibrio campbellii. The novel isolate is able to emit high levels of light. Bioluminescence inhibitory assay showed that the Vibrio sp. MM1 had the highest sensitivity to zinc and the lowest sensitivity to cadmium; EC 50 values were 0.97mgl -1 and 14.54mgl -1 , respectively. The current research shows that even low concentrations of heavy metals can cause a detectable decline in luminescence activity of the novel bacterium Vibrio sp. MM1; hence, it makes a good choice for commercial kits for the purpose of monitoring toxic materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols.

    Science.gov (United States)

    Suchorska-Woźniak, Patrycja; Rac, Olga; Fiedot, Marta; Teterycz, Helena

    2016-11-09

    The article presents the results of the detection of low-concentration C1-C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter of the single tube ranges from several to tens of nanometers. The sepiolite layer itself demonstrated no chemical activity in the presence of volatile organic compounds (VOC), and the passive filter made of this material did not modify the chemical composition of the gaseous atmosphere diffusing to the gas-sensitive layer. The test results revealed that the structural remodelling of the sepiolite that occurs under the influence of temperature, as well as the effect of the filter (a compound with ionic bonds) with molecules of water, has a significant impact on the improvement of the sensitivity of the sensor in relation to volatile organic compounds when compared to the sensor without a filter.

  5. Radium concentration factors in passionfruit (Passiflora foetida) from the Alligator Rivers Region, Northern Territory, Australia

    International Nuclear Information System (INIS)

    Medley, Peter; Bollhöfer, Andreas; Parry, David; Martin, Paul

    2013-01-01

    In this study, uptake of Ra from soil into the edible fruit of the wild passionfruit species Passiflora foetida was investigated, using selective extraction from the soil samples. A wide range of environmental exposure conditions were represented by the locations that were sampled, including both natural soils, and soils influenced by past and present uranium mining activities. The bioavailable 226 Ra fraction in soils was found to be a better predictor of 226 Ra fruit activity concentrations than the total soil activity concentration, or any of the other fractions studied. Concentration Factors (CFs) derived using the bioavailable fraction varied by only a factor of 7 between different locations, whereas CFs derived using other fractions and total soil varied by up to two orders of magnitude. CFs were highest for those soils containing the lowest concentrations of Mg, Ca and Ba, and approached a saturation value at higher soil concentrations. This finding suggests that group II elements influence radium uptake, most likely the result of increased pressure on the plant to take up essential nutrient group II elements from soil with the lower concentrations, with Ra being taken up as an analogue element. It is also possible that at higher concentrations of bioavailable Ca and Mg in the soil, these ions will outcompete Ra for adsorption sites in the soil and/or on the root surfaces. The study also shows that 228 Ra can potentially be a significant contributor to ingestion doses and should also be considered when assessing committed effective doses from the ingestion of fruits. -- Highlights: • Fruit and soil samples were taken from wild growing native passionfruit plants. • The sampling locations were on natural and U mining impacted sites. • Sequential extraction of the soil was undertaken. • Radium-226, radium-228 and other key elements were measured. • Concentration factors show the lowest variability in the bioavailable fraction

  6. Concentration of elements on impregnated paper followed by their determination by peak chromatography

    International Nuclear Information System (INIS)

    Aleskovskaya, V.N.; Aleskovskij, V.B.; Bogdanova, Eh.G.

    1977-01-01

    To increase the limits of detection of ions Au, Ru and others in paper peak chromatography, their concentration is suggested on this very paper due to an increase of the analysed solution volume introduced on the paper. It is shown that deviation from the linear dependence of the peak heights on the determined ion concentration on the primary chromatograph near the limit of detection is explained by sorption of the ion with its precipitate. The concentration by two orders of magnitude enlargeds the concentration ranges of 1 - and Ru(3). The concentration is possible for small amounts of ions for which a nonlinear dependence occurs near the limit of detection

  7. Pinning of fullerene lowest unoccupied molecular orbital edge at the interface with standing up copper phthalocyanine

    International Nuclear Information System (INIS)

    Wang, Chenggong; Irfan, Irfan; Turinske, Alexander J.; Gao, Yongli

    2012-01-01

    The electronic structure evolution of interfaces of fullerene (C 60 ) with copper phthalocyanine (CuPc) on highly oriented pyrolitic graphite (HOPG) and on native silicon oxide has been investigated with ultra-violet photoemission spectroscopy and inverse photoemission spectroscopy. The lowest unoccupied molecular orbital edge of C 60 was found to be pinned at the interface with CuPc on SiO 2 . A substantial difference in the electron affinity of CuPc on the two substrates was observed as the orientation of CuPc is lying flat on HOPG and standing up on SiO 2 . The ionization potential and electron affinity of C 60 were not affected by the orientation of CuPc due to the spherical symmetry of C 60 molecules. We observed band bending in C 60 on the standing-up orientation of CuPc molecules, while the energy levels of C 60 on the flat lying orientation of CuPc molecules were observed to be flat. - Highlights: ► Orientation of copper phthalocyanine (CuPc) on ordered graphite and silicon oxide. ► Pinning of lowest unoccupied molecular orbital edge of C60 to the Fermi level on CuPc. ► No C60 pinning or band bending was observed on flat laying CuPc. ► Results are useful for organic photovoltaic and organic light emitting diode research.

  8. The optimal value of BMI for the lowest risk of osteoporosis in postmenopausal women aged 40-88 years.

    Science.gov (United States)

    Skrzek, A; Kozieł, S; Ignasiak, Z

    2014-06-01

    The aim of this paper is to establish the optimal values of the body mass index (BMI) which would indicate the most favourable preservation of the bone mineral density in postmenopausal women. The material consists of the data of 369 healthy women aged between 40 and 88 years (mean age 67.84, SD=6.70) inhabitants of Wrocław, which were followed up between 2001 and 2006. The absolute measure of bone mineral density (BMD) of the femoral neck was assessed using dual energy X-ray absorptiometry (DEXA), expressed in g/(100mm(2)) and was transformed to T-score values. According to the value of BMI, the women were divided into eight groups, the reference group with value between 18.0 and 21.9kg/m(2) and seven other groups beginning with the value 22.0 with a 2-point interval. Postmenopausal status was defined according to the occurrence of menstruation within the last 360 days. The women with osteopenia and osteoporosis were pooled together and comprised the risk group, whereas the other women comprised the normal group (T-score values above -1.0). The adjusted odds ratio showed the highest value for intervals between 24.0 and 25.9 units of BMI, and the lowest value for interval 26.0-27.9 units of BMI. The Youden index showed the lowest value in the 26.0-27.9BMI kg/m(2) interval. For our sample the optimal value of BMI, with the lowest risk of osteopenia and/or osteoporosis was the value of 26.9kg/m(2). A further increase of BMI does not result in a favourable effect on the bones, it rather intensifies negative phenomena in the body resulting in the onset of many diseases. Copyright © 2014. Published by Elsevier GmbH.

  9. Liquid chromatographic separation and indirect detection of non-absorbing aliphatic compounds using m-nitrophenol as a detection agent

    International Nuclear Information System (INIS)

    Lee, Seung Seok; Kang, Sam Woo; Moon, Young Ja

    1991-01-01

    m-Nitrophenol(m-NP) was a detection agent for the use of the detection and separation of non-absorbing compounds such as aliphatic acids, alcohols, amines and tetraalkylammonium salts by indirect photometric detection in reversed-phase liquid chromatography. Response of samples was investigated to the several factors such as pH, temperature, and concentration of MeOH as well as concentration of detection reagent in mobile phase. The separation of several mixtures were attempted under optimum condition. (Author)

  10. Detection of large-scale concentric gravity waves from a Chinese airglow imager network

    Science.gov (United States)

    Lai, Chang; Yue, Jia; Xu, Jiyao; Yuan, Wei; Li, Qinzeng; Liu, Xiao

    2018-06-01

    Concentric gravity waves (CGWs) contain a broad spectrum of horizontal wavelengths and periods due to their instantaneous localized sources (e.g., deep convection, volcanic eruptions, or earthquake, etc.). However, it is difficult to observe large-scale gravity waves of >100 km wavelength from the ground for the limited field of view of a single camera and local bad weather. Previously, complete large-scale CGW imagery could only be captured by satellite observations. In the present study, we developed a novel method that uses assembling separate images and applying low-pass filtering to obtain temporal and spatial information about complete large-scale CGWs from a network of all-sky airglow imagers. Coordinated observations from five all-sky airglow imagers in Northern China were assembled and processed to study large-scale CGWs over a wide area (1800 km × 1 400 km), focusing on the same two CGW events as Xu et al. (2015). Our algorithms yielded images of large-scale CGWs by filtering out the small-scale CGWs. The wavelengths, wave speeds, and periods of CGWs were measured from a sequence of consecutive assembled images. Overall, the assembling and low-pass filtering algorithms can expand the airglow imager network to its full capacity regarding the detection of large-scale gravity waves.

  11. Biological variables and health status affecting inorganic element concentrations in harbour porpoises (Phocoena phocoena) from Portugal (western Iberian Peninsula)

    International Nuclear Information System (INIS)

    Ferreira, Marisa; Monteiro, Silvia S.; Torres, Jordi; Oliveira, Isabel; Sequeira, Marina; López, Alfredo

    2016-01-01

    The coastal preferences of harbour porpoise (Phocoena phocoena) intensify their exposure to human activities. The harbour porpoise Iberian population is presently very small and information about the threats it endures is vital for the conservation efforts that are being implemented to avoid local extinction. The present study explored the possible relation between the accumulation of trace elements by porpoises and their sex, body length, nutritional state, presence of parasites and gross pathologies. The concentrations of arsenic (As), cadmium (Cd), copper (Cu), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), zinc (Zn) and selenium (Se) were evaluated in 42 porpoises stranded in Portugal between 2005 and 2013. Considering European waters, porpoises stranded in Portugal present the highest Hg concentrations and the lowest Cd concentrations, which may reflect dietary preferences and the geographic availability of these pollutants. While no effect of sex on trace element concentrations was detected, there was a positive relationship between porpoise body length and the concentration of Cd, Hg and Pb. Animals in worse nutritional condition showed higher levels of Zn. Harbour porpoises with high parasite burdens showed lower levels of Zn and As in all analysed tissues and also lower levels of renal Ni, while those showing gross pathologies presented higher Zn and Hg levels. This is the first data on the relationship between trace elements and health-related variables in porpoises from southern European Atlantic waters, providing valuable baseline information about the contamination status of this vulnerable population. - Highlights: • High levels of mercury in harbour porpoises from Portugal. • Evidence of bioaccumulation of non-essential trace elements. • Presence of parasites influenced some essential trace elements. • Evidence of nutritional state effect on Zn levels. • Presence of gross pathologies influenced Zn and Hg levels. - The small harbour

  12. An electrochemical aptasensor for chiral peptide detection using layer-by-layer assembly of polyelectrolyte-methylene blue/polyelectrolyte-graphene multilayer

    International Nuclear Information System (INIS)

    Qin Haixia; Liu Jiyang; Chen Chaogui; Wang Jiahi; Wang Erkang

    2012-01-01

    Highlights: ► An electrochemical aptasensor for selective detection of peptide is constructed. ► This aptasensor is based on grapheme multilayer via layer-by-layer assembly. ► Such multilayer facilitates electron transfer and provides more adsorption sites. - Abstract: Here we demonstrate for the first time that by physically adsorbing aptamer onto conductive film assembled via alternate adsorption of graphene/polyelectrolyte and methylene blue/polyelectrolyte, a label-free electrochemical aptasensor with high sensitivity and selectivity for peptide detection is constructed. Graphene multilayer derived from layer-by-layer assembly has played significant roles in this sensing strategy: allowing accumulation of methylene blue, facilitating electron transfer and providing much more adsorption site. As compared to previous electrochemical aptasensors, the current sensor based on graphene multilayer alternated with electroactive molecule layer offers extremely high capability for sensitive detection of target without interference of environmental surrounding. This electroactive probe-confined graphene multilayer confers great flexibility to combine with differential pulse voltammetry (DPV) together. In the presence of target D entiomer of arginine vasopressin (D-VP), the binding of peptide to aptamer block the electron transfer process of MB, leading to decreased current peak of DPV. By this way, this electrochemical aptasensor based on electroactive molecule-intercalated graphene multilayer provide highly sensitive and specific detection of D-VP with the lowest detectable concentration of 1 ng mL −1 and a wide detection range from 1 to 265 ng mL −1 .

  13. Brief Communication: Comparison of formol-acetone concentration ...

    African Journals Online (AJOL)

    Background: Formol-ether concentration technique is taken as a gold standard method to detect most intestinal parasites; however, because of its low safety and hazardous impact a need for better technique has a paramount importance. Objective: To evaluate a formol- acetone concentration method in comparison with the ...

  14. Fluorescence detection system for microfluidic droplets

    Science.gov (United States)

    Chen, Binyu; Han, Xiaoming; Su, Zhen; Liu, Quanjun

    2018-05-01

    In microfluidic detection technology, because of the universality of optical methods in laboratory, optical detection is an attractive solution for microfluidic chip laboratory equipment. In addition, the equipment with high stability and low cost can be realized by integrating appropriate optical detection technology on the chip. This paper reports a detection system for microfluidic droplets. Photomultiplier tubes (PMT) is used as a detection device to improve the sensitivity of detection. This system improves the signal to noise ratio by software filtering and spatial filter. The fluorescence intensity is proportional to the concentration of the fluorescence and intensity of the laser. The fluorescence micro droplets of different concentrations can be distinguished by this system.

  15. Comparison of two-concentration with multi-concentration linear regressions: Retrospective data analysis of multiple regulated LC-MS bioanalytical projects.

    Science.gov (United States)

    Musuku, Adrien; Tan, Aimin; Awaiye, Kayode; Trabelsi, Fethi

    2013-09-01

    Linear calibration is usually performed using eight to ten calibration concentration levels in regulated LC-MS bioanalysis because a minimum of six are specified in regulatory guidelines. However, we have previously reported that two-concentration linear calibration is as reliable as or even better than using multiple concentrations. The purpose of this research is to compare two-concentration with multiple-concentration linear calibration through retrospective data analysis of multiple bioanalytical projects that were conducted in an independent regulated bioanalytical laboratory. A total of 12 bioanalytical projects were randomly selected: two validations and two studies for each of the three most commonly used types of sample extraction methods (protein precipitation, liquid-liquid extraction, solid-phase extraction). When the existing data were retrospectively linearly regressed using only the lowest and the highest concentration levels, no extra batch failure/QC rejection was observed and the differences in accuracy and precision between the original multi-concentration regression and the new two-concentration linear regression are negligible. Specifically, the differences in overall mean apparent bias (square root of mean individual bias squares) are within the ranges of -0.3% to 0.7% and 0.1-0.7% for the validations and studies, respectively. The differences in mean QC concentrations are within the ranges of -0.6% to 1.8% and -0.8% to 2.5% for the validations and studies, respectively. The differences in %CV are within the ranges of -0.7% to 0.9% and -0.3% to 0.6% for the validations and studies, respectively. The average differences in study sample concentrations are within the range of -0.8% to 2.3%. With two-concentration linear regression, an average of 13% of time and cost could have been saved for each batch together with 53% of saving in the lead-in for each project (the preparation of working standard solutions, spiking, and aliquoting). Furthermore

  16. Transport of indoleacetic acid in intact corn coleoptiles

    International Nuclear Information System (INIS)

    Parker, K.E.; Briggs, W.R.

    1990-01-01

    We have characterized the transport of [ 3 H]indoleacetic acid (IAA) in intact corn (Zea mays L.) coleoptiles. We have used a wide range of concentrations of added IAA (28 femtomoles to 100 picomoles taken up over 60 minutes). The shape of the transport curve varies with the concentration of added IAA, although the rate of movement of the observed front of tracer is invariant with concentration. At the lowest concentration of tracer used, the labeled IAA in the transport stream is not detectably metabolized or immobilized, curvature does not develop as a result of tracer application, and normal phototropic and gravitropic responsiveness are not affected. Therefore we believe we are observing the transport of true tracer quantities of labeled auxin at this lowest concentration

  17. Determination of the lowest critical power levels of the Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Huy, Ngo Quang [Centre for Nuclear Technique Application, Ho Chi Minh City (Viet Nam); Thong, Ha Van; Long, Vu Hai; Binh, Do Quang; Nghiem, Huynh Ton; Tuan, Nguyen Minh; Vien, Luong Ba; Vinh, Le Vinh [Nuclear Research Inst., Da Lat (Viet Nam)

    1994-10-01

    This paper presents the experimental methods for determining critical states of the Dalat Nuclear Research Reactor containing an extraneous neutron source induced by gamma ray reactions on beryllium in the reactor. The lowest critical power levels are measured at various moments after the reactor is shut down following 100 hours of its continuous operation. Th power levels vary from (0.5-1.2) x 10{sup -4} of P{sub n}, i.e. (25-60)W to (1.1-1.6) x 10{sup -5} of P{sub n}, i.e. (5.5-8)W at corresponding times of 4 days to 13 days after the reactor is shut down. However the critical power must be chosen greater than 500 W to sustain the steady criticality of the reactor for a long time. (author). 3 refs. 4 figs. 1 tab.

  18. Total solar eclipse of 16 February 1980 and the vertical profiles of atmospheric parameters in the lowest 200M

    Digital Repository Service at National Institute of Oceanography (India)

    RameshBabu, V.; Sastry, J.S.

    Vertical profiles of air temperature, wind and humidity at Raichur (16 degrees 12'N and 77 degrees 21'E) in the lowest 200m of the atmosphere are presented for the period 15-18 February 1980. The effect of the total solar eclipse, on 16 February...

  19. Determination of Trace Anions in Concentrated Hydrogen Peroxide by Direct Injection Ion Chromatography with Conductivity Detection after Pt-Catalyzed On-Line Decomposition

    International Nuclear Information System (INIS)

    Kim, Do Hee; Lee, Bo Kyung; Lee, Dong Soo

    1999-01-01

    A method has been developed for the determination of trace anion impurities in concentrated hydrogen peroxide. The method involves on-line decomposition of hydrogen peroxide, ion chromatographic separation and subsequent suppressed-type conductivity detection. H 2 O 2 is decomposed in Pt-catalyst filled Gore-Tex membrane tubing and the resulting aqueous solution containing analytes is introduced to the injection valve of an ion chromatograph for periodic determinations. The oxygen gas evolving within the membrane tubing escapes freely through the membrane wall causing no problem in ion chromatographic analysis. Decomposition efficiency is above 99.99% at a flow rate of 0.4mL/min for a 30% hydrogen peroxide concentration. Analytes are quantitatively retained. The analysis results for several brands of commercial hydrogen peroxides are reported

  20. A Monoclonal Antibody Based Capture ELISA for Botulinum Neurotoxin Serotype B: Toxin Detection in Food

    Directory of Open Access Journals (Sweden)

    Larry H. Stanker

    2013-11-01

    Full Text Available Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT, produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A–H have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD’s for individual antibodies ranging from 10 to 48 × 10−11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D., ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule and readily detects toxin in those food samples tested.

  1. A monoclonal antibody based capture ELISA for botulinum neurotoxin serotype B: toxin detection in food.

    Science.gov (United States)

    Stanker, Larry H; Scotcher, Miles C; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert

    2013-11-18

    Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A-H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD's) for individual antibodies ranging from 10 to 48 × 10-11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested.

  2. Summer concentrations of NMHCs in ambient air of the Arctic and Antarctic

    Energy Technology Data Exchange (ETDEWEB)

    Hellen, H.; Paatero, J.; Hakola, H.; Virkkula, A. [Finnish Meteorological Inst., Helsinki (Finland); Leck, C. [Stockholm Univ. (Sweden). Dept. of Meteorology

    2012-11-01

    Summer concentrations of C{sub 2}-C{sub 6} non-methane hydrocarbons (NMHCs) were measured in Antarctica and in the Arctic in 2008. The results show that NMHC concentrations are on average five times higher in the Arctic than in Antarctica. In Antarctica, there were few concentration peaks, but during most of the remaining time concentrations were below or close to the detection limits. Over the Arctic pack ice area north of 80 deg, concentrations of most of the measured NMHCs were always above the detection limits. No differences based on air-mass origin were detected in Antarctica, but samples collected over the central Arctic Ocean showed higher concentrations in air masses being advected from the Kara Sea and the western-central Arctic Ocean. The relatively higher NMHC-to-ethyne molar ratios calculated for samples collected over the central Arctic Ocean suggest additional alkane sources in the region. (orig.)

  3. Plasma concentration of ionized calcium in healthy iguanas.

    Science.gov (United States)

    Dennis, P M; Bennett, R A; Harr, K E; Lock, B A

    2001-08-01

    To measure plasma concentration of ionized calcium in healthy green iguanas. Prospective study. 9 juvenile and 21 (10 male, 11 female) adult iguanas. Blood samples were obtained from each iguana, and plasma calcium, glucose, phosphorus, uric acid, total protein, albumin, globulin, potassium, and ionized calcium concentrations, aspartate transaminase (AST) activity, and pH were measured. Heparinized blood was used for measurement of ionized calcium concentration and blood pH. A CBC was also performed to assess the health of the iguanas. Significant differences were not detected among the 3 groups (juveniles, males, and females) with regard to ionized calcium concentration. Mean ionized calcium concentration measured in blood was 1.47 +/- 0.105 mmol/L. Significant differences were detected between juveniles and adults for values of phosphorus, glucose, total protein, albumin, globulin, and AST activity. Ionized calcium concentration provides a clinical measurement of the physiologically active calcium in circulation. Evaluation of physiologically active calcium in animals with suspected calcium imbalance that have total plasma calcium concentrations within reference range or in gravid animals with considerably increased total plasma calcium concentrations is vital for determining a therapeutic plan. Accurate evaluation of calcium status will provide assistance in the diagnosis of renal disease and seizures and allow for better evaluation of the health status of gravid female iguanas.

  4. AN APPLICATION OF FLOW INJECTION ANALYSIS WITH GAS DIFFUSION AND SPECTROPHOTOMETRIC DETECTION FOR THE MONITORING OF DISSOLVED SULPHIDE CONCENTRATION IN ENVIRONMENTAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Malwina Cykowska

    2014-10-01

    Full Text Available The monitoring of the concentration of sulphide is very important from the environment point of view because of high toxicity of hydrogen sulphide. What is more hydrogen sulphide is an important pollution indicator. In many cases the determination of sulphide is very difficult due to complicated matrix of some environmental samples, which causes that most analytical methods cannot be used. Flow injection analysis allows to avoid matrix problem what makes it suitable for a wide range of applications in analytical laboratories. In this paper determination of dissolved sulphide in environmental samples by gas-diffusion flow injection analysis with spectrophotometric detection was presented. Used gas-diffusion separation ensures the elimination of interferences caused by sample matrix and gives the ability of determination of sulphides in coloured and turbid samples. Studies to optimize the measurement conditions and to determine the value of the validation parameters (e.g. limit of detection, limit of quantification, precision, accuracy were carried out. Obtained results confirm the usefulness of the method for monitoring the concentration of dissolved sulphides in water and waste water. Full automation and work in a closed system greatly reduces time of analysis, minimizes consumption of sample and reagents and increases safety of analyst’s work.

  5. Influence of atmospheric stability and transport on CH{sub 4} concentrations in northern Spain

    Energy Technology Data Exchange (ETDEWEB)

    García, M. Ángeles, E-mail: magperez@fa1.uva.es; Sánchez, M. Luisa; Pérez, Isidro A.; Ozores, Marta I.; Pardo, Nuria

    2016-04-15

    Continuous methane (CH{sub 4}) concentrations were measured in Northern Spain over two years (2011–2012) by multi-point sampling at 1.8, 3.7 and 8.3 m using a Picarro analyser. The technique is based on cavity ring-down spectroscopy. The contrast in mean concentrations was about 1.2 ppb, with 95th percentiles differing by 2.2 ppb and mean minimum concentrations proving similar. Temporal variations of CH{sub 4} were also analysed, with a similar seasonal variability being found for the three heights. The highest CH{sub 4} concentrations were obtained in late autumn and winter and the lowest in summer, yielding a range of 52 ppb. This variation may depend on the active photochemical reaction with OH radical during a period of intense solar radiation and changes in soil conditions together with variations in emissions. Peak concentration levels were recorded at night-time, between 5:00–7:00 GMT, with mean values ranging between 1920 and 1923 ppb. The lowest value, around 1884 ppb, was obtained at 16:00 GMT. This diurnal variation was mainly related to vertical mixing and photochemistry. Therefore, CH{sub 4} concentrations were also examined using the bulk Richardson number (R{sub B}) as a stability indicator. Four groups were distinguished: unstable cases, situations with pure shear flow, transitional stages and drainage flows. The highest contrast in mean CH{sub 4} concentrations between lower and upper heights was obtained for the transition and drainage cases, mainly associated to high concentrations from nearby sources. The impact of long range transport was analysed by means of 3-day isobaric backward air mass trajectories, which were calculated taking into account origins from Europe, Africa, the Atlantic Ocean and Local conditions. Assessment of the results showed the influence of S and SE wind sectors, especially with Local conditions associated with low winds. Finally, an estimation of the background CH{sub 4} concentration in the study period provided an

  6. A chromosomally based luminescent bioassay for mercury detection in red soil of China

    Energy Technology Data Exchange (ETDEWEB)

    Wei, He [Chinese Academy of Sciences, Nanking (China). State Key Lab. of Soil and Sustainable Agriculture; Nanjing Normal Univ., Nanking (China). College of Life Science; Cheng, Han; Ting, Mao; Zhong, Wen-Hui [Nanjing Normal Univ., Nanking (China). College of Chemistry and Environmental Science; Lin, Xian-Gui [Chinese Academy of Sciences, Nanking (China). State Key Lab. of Soil and Sustainable Agriculture

    2010-07-15

    A luminescent reporter gene system was constructed by fusing the mercury-inducible promoter, P{sub merT}, and its regulatory gene, merR, with a promoterless reporter gene EGFP. A stable and nonantibiotic whole-cell reporter (BMB-ME) was created by introducing the system cassette into the chromosome of Pseudomonas putida strain and then applied it for mercury detection in the red soil of China. Spiked with 10 and 100 {mu}g g{sup -1} Hg{sup 2+} and after 15 and 30 days incubation, soil samples were extracted and evaluated water soluble, bioavailable, organic matter bound, and residual fractions of mercury by both BMB-ME and chemical way. The expression of EGFP was confirmed in soil extraction, and fluorescence intensity was quantified by luminescence spectrometer. The sensor strain BMB-ME appeared to have a detection range similar to that of reversed-phase high-performance liquid chromatography method. The optimal temperature for EGFP expression was 35 C and the lowest detectable concentration of Hg{sup 2+} 200 nM. Cu{sup 2+}, Fe{sup 2+}, Mn{sup 2+}, Sn{sup 2+}, Zn{sup 2+}, Co{sup 2+}, Ag{sup +}, Ba{sup 2+}, Mg{sup 2+}, and Pb{sup 2+} ions at nanomolar level did not interfere with the measurement. These results showed that the BMB-ME constitute an adaptable system for easy sensing of small amounts of mercury in the red soil of China. (orig.)

  7. Elevated blood harmane (1-methyl-9H-pyrido[3,4-b]indole) concentrations in essential tremor.

    Science.gov (United States)

    Louis, Elan D; Jiang, Wendy; Pellegrino, Kathryn M; Rios, Eileen; Factor-Litvak, Pam; Henchcliffe, Claire; Zheng, Wei

    2008-03-01

    Essential tremor (ET) is a widespread late-life neurological disease. Genetic and environmental factors likely play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-b]indole) is a potent tremor-producing neurotoxin. In 2002, we demonstrated elevated blood harmane concentrations in an initial sample of 100 ET cases compared to 100 controls. Between 2002 and 2007, we assembled a new and larger sample of ET cases and controls. We now attempt to replicate our previous findings. Cases and controls were frequency-matched on age, gender, and race. Blood harmane concentrations were quantified by high-performance liquid chromatography. Subjects comprised 150 ET cases and 135 controls (mean age 65.3+/-15.5 vs. 65.5+/-14.2 years, p=0.94). Mean log blood harmane concentration was approximately 50% higher in cases than controls (0.50+/-0.54g(-10)/ml vs. 0.35+/-0.62g(-10)/ml, p=0.038). In a logistic regression analysis, log blood harmane concentration was associated with ET (OR(adjusted) 1.56, 95% CI 1.01-2.42, p=0.04), and odds of ET was 1.90 (95% CI 1.07-3.39, p=0.029) in the highest versus lowest log blood harmane tertile. Log blood harmane was highest in ET cases with familial ET (0.53+/-0.57g(-10)/ml), intermediate in cases with sporadic ET (0.43+/-0.45g(-10)/ml) and lowest in controls (0.35+/-0.62g(-10)/ml) (test for trend, p=0.026). Blood harmane appears to be elevated in ET. The higher concentrations in familial ET suggests that the mechanism may involve genetic factors.

  8. Solar Cycle 24 UV Radiation: Lowest in more than 6 Decades

    Science.gov (United States)

    Schroder, Klaus-Peter; Mittag, Marco; Schmitt, J. H. M. M.

    2015-01-01

    Using spectra taken by the robotic telescope ``TIGRE'' (see Fig. 1 and the TIGRE-poster presented by Schmitt et al. at this conference) and its mid-resolution (R=20,000) HEROS double-channel echelle spectrograph, we present our measurements of the solar Ca II H&K chromospheric emission. Using moonlight, we applied the calibration and definition of the Mt. Wilson S-index , which allows a direct comparison with historic observations, reaching back to the early 1960's. At the same time, coming from the same EUV emitting plage regions, the Ca II H&K emission is a good proxy for the latter, which is of interest as a forcing factor in climate models. Our measurements probe the weak, asynchronous activity cycle 24 around its 2nd maximum during the past winter. Our S-values suggest that this maximum is the lowest in chromospheric emission since at least 60 years -- following the longest and deepest minimum since a century. Our observations suggest a similarly long-term (on a scale of decades) low of the far-UV radiation, which should be considered by the next generation of climate models. The current, very interesting activity behaviour calls for a concerted effort on long-term solar monitoring.

  9. Growth, aboveground biomass, and nutrient concentration of young Scots pine and lodgepole pine in oil shale post-mining landscapes in Estonia.

    Science.gov (United States)

    Kuznetsova, Tatjana; Tilk, Mari; Pärn, Henn; Lukjanova, Aljona; Mandre, Malle

    2011-12-01

    The investigation was carried out in 8-year-old Scots pine (Pinus sylvestris L.) and lodgepole pine (Pinus contorta var. latifolia Engelm.) plantations on post-mining area, Northeast Estonia. The aim of the study was to assess the suitability of lodgepole pine for restoration of degraded lands by comparing the growth, biomass, and nutrient concentration of studied species. The height growth of trees was greater in the Scots pine stand, but the tree aboveground biomass was slightly larger in the lodgepole pine stand. The aboveground biomass allocation to the compartments did not differ significantly between species. The vertical distribution of compartments showed that 43.2% of the Scots pine needles were located in the middle layer of the crown, while 58.5% of the lodgepole pine needles were in the lowest layer of the crown. The largest share of the shoots and stem of both species was allocated to the lowest layer of the crown. For both species, the highest NPK concentrations were found in the needles and the lowest in the stems. On the basis of the present study results, it can be concluded that the early growth of Scots pine and lodgepole pine on oil shale post-mining landscapes is similar.

  10. Direct detection of ammonium ion by means of oxygen electrocatalysis at a copper-polyaniline composite on a screen-printed electrode

    International Nuclear Information System (INIS)

    Zhybak, Mykhailo T.; Vagin, Mikhail Yu.; Beni, Valerio; Liu, Xianjie; Turner, Anthony P. F.; Dempsey, Eithne; Korpan, Yaroslav I.

    2016-01-01

    We describe a composite material for use in electrochemical oxygen reduction. A screen-printed electrode (SPE) was consecutively modified with electrodeposited copper, a Nafion membrane and electropolymerized polyaniline (PANi) to give an electrocatalytic composite of type PANi/Nafion/Cu_2O/SPE that displays good electrical conductivity at neutral pH values. It is found that the presence of ammonia causes complex formation with Cu(I), and this causes electroreduction of oxygen to result in an increased cathodic current. The finding was applied to the quantification of ammonium ions in the 1 to 1000 μM concentration range by amperometry at −0.45 V (vs. Ag/AgCl). This Faradaic phenomenon offers the advantage of direct voltammetric detection, one of the lowest known limits of detection (0.5 μM), and high sensitivity (250 mA∙M"−"1∙cm"−"2). It was applied to the determination of ammonium ion in human serum where it compared well with the photometric routine approach for clinical analysis using glutamate dehydrogenase. (author)

  11. Seasonal variation in radon concentration in the atmosphere simultaneously measured in Donghae on Korean peninsula, Matsue on Shimane peninsula, and Oki island in the sea of Japan

    International Nuclear Information System (INIS)

    Yoshioka, Katsuhiro; Iida, Takao; Kim, Yoon Shin

    2008-01-01

    We measured simultaneously radon concentration in the atmosphere at Donghae, Oki Island and Matsue. In Donghae, radon concentration had peaks in the winter and summer and lower values in the spring. It was the highest in the winter and lowest in the summer in Oki Island, in Matsue, the highest in the fall and lowest in the summer. The timing and frequency of arrival air mass from the ocean and the land were different among the three measuring points. The highest values in Donghae and Oki Island were because of effects of radon flow from Eurasian continent in the winter. The inversion layer often formed in the atmospheric boundary layer over the land area around the Sea of Japan caused the peak values in the summer in Donghae. The atmosphere over Oki Island is always mixed with that over the ocean because the island is small. Radon escaping from the ground of the island does not stay with the surface layer even at night, therefore, diurnal variation was almost none throughout the year. Air mass with low radon concentration coming from the Pacific Ocean caused the lowest values in the summer. In Matsue, the peak was found in the fall in which occurrences of surface inversion layer is most common in the year. (author)

  12. Determination of Anionic Detergent Concentration of Karasu Stream in Sinop (Turkey

    Directory of Open Access Journals (Sweden)

    Ayşe Gündoğdu

    2018-02-01

    Full Text Available The study was achieved between May 2014 and April 2015 at the Karasu Creek located in the province of Sinop. It was conducted to determine anionic detergent pollution and some physicochemical properties (pH, temperature, conductivity, salinity, dissolved oxygen, total hardness, chemical oxygen demand, phosphate PO4-3, total nitrogen. The anionic detergent concentration of the stations was determined on a monthly basis. Seasonally averaged values of the anionic detergent was measured as the highest value in the autumn season. The lowest values of anionic detergent were found in stations in winter and spring. The increase in the concentration of anionic detergent is caused by population growth in residential areas, increased agricultural activities and rains, and that chemicals move to riverbed from terrestrial areas with rain water.

  13. The influence of bias magnetization of nanoparticles on GMR sensor signal and sensitivity for the ultra-low concentration detection

    Science.gov (United States)

    Zhang, Yang; Xu, Jie; Cao, Derang; Li, Qiang; Zhao, Guoxia; Sun, Nian X.; Li, Shandong

    2018-05-01

    In the broad research of the GMR bio-sensing technology, it is vital to explore appropriate magnetic labels and its influences on the detection signal. In this work, four kinds of ferrite particles of γ-Fe2O3, CoFe2O4, NiFe2O4 and NiZnFe2O4 were prepared through calcining the Dimethyl Formamide (DMF) solution of the transition metal nitrates [Fe(NO3)3 and X(NO3)2, X = Co, Ni, Zn] to study the effect of magnetic properties on detection signals using a DC in-plane measuring method. It was revealed that for four particles, the output voltage differences |ΔV| between with and without magnetic particles exhibit log-linear functions of the particles concentrations x in the range from 0.1 to 10 ng/mL. A very low limitation of detection (LOD) of 0.1 ng/mL for all the samples was obtained, which is two orders smaller than that in the previous work. Moreover, the change of output voltage difference at the LOD (|ΔVlim|) is proportional to the magnetization at bias field (bias magnetization, Mbias), which indicates that larger Mbias leads to a lower LOD. This work provides a useful guidance in selecting or preparing magnetic labels to enhance the sensitivity of GMR biosensors.

  14. Rapid analysis of malachite green and leucomalachite green in fish muscles with surface-enhanced resonance Raman scattering.

    Science.gov (United States)

    Zhang, Yuanyuan; Yu, Wansong; Pei, Lu; Lai, Keqiang; Rasco, Barbara A; Huang, Yiqun

    2015-02-15

    Surface-enhanced resonance Raman scattering (SERRS) coupled with gold nanospheres was applied for rapid analysis of the hazardous substances malachite green (MG) and leucomalachite green (LMG) in fish muscle tissues. The lowest concentration of MG that could be detected was 0.5ngmL(-1) with high linear correlation (R(2)=0.970-0.998) between MG concentration and intensities of characteristic Raman peaks. A simplified sample preparation method taking less than 1h for recovering MG and LMG in fish fillets was developed for SERRS analysis, and 4-8 samples could be handled in parallel. MG and LMG could be detected in extracts of tilapia fish fillets at as low as 2ngg(-1) with SERRS and a simple principle component analysis method. For six other fish species, the lowest detectable concentration of MG ranged from 1ngg(-1) to 10ngg(-1). This study provides a new sensitive approach for the detection of trace amounts of the prohibited drugs MG and LMG in muscle food, which has the potential for rapidly screening a large number of samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Optimization in the nuclear fuel cycle II: Concentration of alpha emitters in the air

    International Nuclear Information System (INIS)

    Pereira, W.S.; Silva, A.X.; Lopes, J.M.; Carmo, A.S.; Mello, C.R.; Fernandes, T.S.; Kelecom, A.

    2017-01-01

    Optimization is one of the bases of radioprotection and aims to move doses away from the dose limit that is the borderline of acceptable radiological risk. The work aims to use the monitoring of the concentration of alpha emitters in the air as a tool of the optimization process. We analyzed 27 sampling points of airborne alpha concentration in a nuclear fuel cycle facility. The monthly averages were considered statistically different, the highest in the month of February and the lowest in the month of August. All other months were found to have identical mean activity concentration values. Regarding the sampling points, the points with the highest averages were points 12, 15 and 9. These points were indicated for the beginning of the optimization process. Analysis of the production of the facility should be performed to verify possible correlations between production and concentration of alpha emitters in the air

  16. An exploratory study of competition scores and salivary cortisol concentrations in Warmblood horses.

    Science.gov (United States)

    Munk, R; Jensen, R B; Palme, R; Munksgaard, L; Christensen, J W

    2017-10-01

    The main objective of this explorative study was to describe the relationship between competition scores and salivary cortisol concentrations in young horses during dressage and showjumping competitions. The study also investigated whether the diurnal rhythm of salivary cortisol concentrations was affected by competition over consecutive days compared with the home environment. Saliva samples were collected from 126 dressage horses and showjumpers in their home environment and at 3 different events. The relationship between scores given by judges at the competition and cortisol concentrations at the event was assessed. The results demonstrated that competition scores correlated positively to baseline cortisol concentrations at one of 3 events (r = 0.53, P cortisol concentrations followed a diurnal rhythm with the highest concentrations measured in the morning and the lowest in the evening, both at home and in the competition environment (P cortisol concentrations were greater during the competitions than at home (P cortisol concentrations at competition, and exercise caused cortisol concentrations to increase in both showjumpers and dressage horses (P cortisol concentrations was maintained in the novel environment. Dressage horses demonstrated greater baseline cortisol concentrations at competition than showjumpers, suggesting that they may perceive the novel environment as more stressful. Furthermore, there was no consistent relationship between baseline salivary cortisol concentrations and competition scores across the events. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Distribution of gaseous and particle-bound Hg concentrations at the sites representative for urban and non-urban zones of Silesia Province

    Directory of Open Access Journals (Sweden)

    Pyta Halina

    2018-01-01

    Full Text Available The basic features of the distribution of total gaseous (TGM and particle-bound mercury (PBM concentrations were determined for a five locations representative for urban (Bielsko-Biała, Lubliniec, Zabrze and rural areas (Godów, Złoty Potok of Silesia Province. Gaseous mercury concentrations were measured (1 continuously - the automatic 1h TGM measurements in Zloty Potok and Zabrze and (2 non-continuously manual 24h TGM measurements with a pre-concentration of the Hg on gold traps (Bielsko-Biała, Lubliniec, Godów. The PBM concentrations were measured non-continuously by taking PM2.5 samples. The Hg content was determined by using a CVAAS method. The highest average concentration of TGM was recorded in Zabrze (2.8ng/m3, significantly lower (2.0ng/m3 in Bielsko-Biała and in the non-urban station in Godów, the lowest concentration (<2.0 ng/m3 was observed in Lubliniec and at the regional background station in Zloty Potok. The results obtained for TGM concentrations exceeded the European average level of 1.5 ng/m3 (AirBase, 2014. The highest average PBM concentration, associated with PM2.5, was obtained in Zabrze (70pg/m3, more than 20% lower results were obtained in Bielsko-Biała and Godów, finally, the lowest one (lower by about 40% in comparison with Zabrze were obtained in Lubliniec and Złoty Potok. Moreover, an enrichment of Hg concentration in PM was observed with the increasing of the PM content, during the heating season.

  18. Real-time detection with AdaBoost-svm combination in various face orientation

    Science.gov (United States)

    Fhonna, R. P.; Nasution, M. K. M.; Tulus

    2018-03-01

    Most of the research has used algorithm AdaBoost-SVM for face detection. However, to our knowledge so far there is no research has been facing detection on real-time data with various orientations using the combination of AdaBoost and Support Vector Machine (SVM). Characteristics of complex and diverse face variations and real-time data in various orientations, and with a very complex application will slow down the performance of the face detection system this becomes a challenge in this research. Face orientation performed on the detection system, that is 900, 450, 00, -450, and -900. This combination method is expected to be an effective and efficient solution in various face orientations. The results showed that the highest average detection rate is on the face detection oriented 00 and the lowest detection rate is in the face orientation 900.

  19. Determination of the levels of some heavy metals in urban run-off ...

    African Journals Online (AJOL)

    ... were determined using Atomic Absorption Spectrophotometric technique Zinc, iron and cadmium were found in very concentration in the Urban sediment from these cities whilst for most of the locations, lead was found to be below the detection level. Iron has the highest mean concentration while lead had the lowest level.

  20. Improvement of fragment and primer selection for mutation detection by denaturing gradient gel electrophoresis

    NARCIS (Netherlands)

    Wu, Y; Hayes, VM; Osinga, J; Mulder, IM; Looman, MWG; Buys, CHCM; Hofstra, RMW

    1998-01-01

    Denaturing gradient gel electrophoresis (DGGE) is one of the most powerful methods for mutation detection currently available. For successful application the appropriate selection of PCR fragments and PCR primers is crucial. The sequence of interest should always be within the domain with the lowest

  1. Pesticide concentrations in wetlands on the Lake Traverse Indian Reservation, South and North Dakota, July 2015

    Science.gov (United States)

    Carter, Janet M.; Thompson, Ryan F.

    2016-05-04

    During July 2015, water samples were collected from 18 wetlands on the Lake Traverse Indian Reservation in northeastern South Dakota and southeastern North Dakota and analyzed for physical properties and 54 pesticides. This study by the U.S. Geological Survey in cooperation with the Sisseton-Wahpeton Oyate was designed to provide an update on pesticide concentrations of the same 18 wetlands that were sampled for a reconnaissance-level assessment during July 2006. The purpose of this report is to present the results of the assessment of pesticide concentrations in selected Lake Traverse Indian Reservation wetlands during July 2015 and provide a comparison of pesticide concentrations between 2006 and 2015.Of the 54 pesticides that were analyzed for in the samples collected during July 2015, 47 pesticides were not detected in any samples. Seven pesticides—2-chloro-4-isopropylamino-6-amino-s-triazine (CIAT); 2,4–D; acetachlor; atrazine; glyphosate; metolachlor; and prometon—were detected in the 2015 samples with estimated concentrations or concentrations greater than the laboratory reporting level, and most pesticides were detected at low concentrations in only a few samples. Samples from all wetlands contained at least one detected pesticide. The maximum number of pesticides detected in a wetland sample was six, and the median number of pesticides detected was three.The most commonly detected pesticides in the 2015 samples were atrazine and the atrazine degradate CIAT (also known as deethylatrazine), which were detected in 14 and 13 of the wetlands sampled, respectively. Glyphosate was detected in samples from 11 wetlands, and metolachlor was detected in samples from 10 wetlands. The other detected pesticides were 2,4–D (4 wetlands), acetochlor (3 wetlands), and prometon (1 wetland).The same pesticides that were detected in the 2006 samples were detected in the 2015 samples, with the exception of simazine, which was detected only in one sample in 2006

  2. Low tube voltage CT for improved detection of pancreatic cancer: detection threshold for small, simulated lesions

    International Nuclear Information System (INIS)

    Holm, Jon; Loizou, Louiza; Albiin, Nils; Kartalis, Nikolaos; Leidner, Bertil; Sundin, Anders

    2012-01-01

    Pancreatic ductal adenocarcinoma is associated with dismal prognosis. The detection of small pancreatic tumors which are still resectable is still a challenging problem. The aim of this study was to investigate the effect of decreasing the tube voltage from 120 to 80 kV on the detection of pancreatic tumors. Three scanning protocols was used; one using the standard tube voltage (120 kV) and current (160 mA) and two using 80 kV but with different tube currents (500 and 675 mA) to achieve equivalent dose (15 mGy) and noise (15 HU) as that of the standard protocol. Tumors were simulated into collected CT phantom images. The attenuation in normal parenchyma at 120 kV was set at 130 HU, as measured previously in clinical examinations, and the tumor attenuation was assumed to differ 20 HU and was set at 110HU. By scanning and measuring of iodine solution with different concentrations the corresponding tumor and parenchyma attenuation at 80 kV was found to be 185 and 219 HU, respectively. To objectively evaluate the differences between the three protocols, a multi-reader multi-case receiver operating characteristic study was conducted, using three readers and 100 cases, each containing 0–3 lesions. The highest reader averaged figure-of-merit (FOM) was achieved for 80 kV and 675 mA (FOM = 0,850), and the lowest for 120 kV (FOM = 0,709). There was a significant difference between the three protocols (p < 0,0001), when making an analysis of variance (ANOVA). Post-hoc analysis (students t-test) shows that there was a significant difference between 120 and 80 kV, but not between the two levels of tube currents at 80 kV. We conclude that when decreasing the tube voltage there is a significant improvement in tumor conspicuity

  3. Prediction of indoor radon concentration based on residence location and construction

    International Nuclear Information System (INIS)

    Maekelaeinen, I.; Voutilainen, A.; Castren, O.

    1992-01-01

    We have constructed a model for assessing indoor radon concentrations in houses where measurements cannot be performed. It has been used in an epidemiological study and to determine the radon potential of new building sites. The model is based on data from about 10,000 buildings. Integrated radon measurements were made during the cold season in all the houses; their geographic coordinates were also known. The 2-mo measurement results were corrected to annual average concentrations. Construction data were collected from questionnaires completed by residents; geological data were determined from geological maps. Data were classified according to geographical, geological, and construction factors. In order to describe different radon production levels, the country was divided into four zones. We assumed that the factors were multiplicative, and a linear concentration-prediction model was used. The most significant factor in determining radon concentration was the geographical region, followed by soil type, year of construction, and type of foundation. The predicted indoor radon concentrations given by the model varied from 50 to 440 Bq m -3 . The lower figure represents a house with a basement, built in the 1950s on clay soil, in the region with the lowest radon concentration levels. The higher value represents a house with a concrete slab in contact with the ground, built in the 1980s, on gravel, in the region with the highest average radon concentration

  4. The Characteristics and Potential Source Area Analysis of PM2.5 Concentration for Zhengzhou during 2016

    Science.gov (United States)

    Li, D.; Liu, J.; Li, S.; Wang, C.; Zhou, S.

    2018-04-01

    This study used the HYSPLIT-4 model combined with cluster analysis, potential source pollution contribution functions and other methods to analyse the ground air pollution monitoring data and meteorological data in Zhengzhou during 2016. The results showed that: 1) the level of PM2.5 reached the low value in summer. The PM2.5 concentration reached the highest level in December and reached the lowest level in August. The daily variation characteristics of PM2.5 concentration in different seasons were roughly the same, and it had an obviously "double-peak" structure. 2) The annual PM2.5 concentration was positively correlated with atmospheric pressure and relative humidity. The annual PM2.5 concentration was negatively correlated with temperature, visibility, precipitation, and wind speed. 3) In winter, the air mass trajectory that through the northern Sichuan - Gansu - Shaanxi - Hubei was polluted seriously, and the level of PM2.5 was the highest which reached to 202.13 μg/m3. In summer, the air mass trajectory that came from Hubei was the lowest level with the value is 40.17 μg/m3. 4) The potential source areas located in northwest of Zhengzhou, Gansu, Hubei and Beijing-Tianjin-Hebei region in spring. The surrounding of Zhengzhou contributed to the pollution of Zhengzhou. The potential source areas appeared in Shaanxi, Sichuan, and Qinghai, the border between Ningxia and Inner Mongolia in autumn. In winter the potential source areas located in Jiangsu, Hubei, Henan, eastern of Shanxi, southern of Shanxi, Ningxia and the area of Yellow Sea, etc.

  5. Quaternary ammonium promoted ultra selective and sensitive fluorescence detection of fluoride ion in water and living cells.

    Science.gov (United States)

    Li, Long; Ji, Yuzhuo; Tang, Xinjing

    2014-10-21

    Highly selective and sensitive fluorescent probes with a quaternary ammonium moiety have been rationally designed and developed for fast and sensitive fluorescence detection of fluoride ion (F(-) from NaF, not TBAF) in aqueous solution and living cells. With the sequestration effect of quaternary ammonium, the detection time was less than 2 min and the detection limit of fluoride ion was as low as 0.57 ppm that is among the lowest detection limits in aqueous solutions of many fluoride fluorescence probes in the literature.

  6. Subthreshold neutron interrogator for detection of radioactive materials

    Science.gov (United States)

    Evans, Michael L.; Menlove, Howard O.; Baker, Michael P.

    1980-01-01

    A device for detecting fissionable material such as uranium in low concentrations by interrogating with photoneutrons at energy levels below 500 keV, and typically about 26 keV. Induced fast neutrons having energies above 500 keV by the interrogated fissionable material are detected by a liquid scintillator or recoil proportional counter which is sensitive to the induced fast neutrons. Since the induced fast neutrons are proportional to the concentration of fissionable material, detection of induced fast neutrons indicate concentration of the fissionable material.

  7. Effect of silage type and energy concentration on conjugated linoleic acid (CLA) in milk fat from dairy cows

    DEFF Research Database (Denmark)

    Nielsen, T.S.; Sejrsen, K.; Andersen, H.R

    2004-01-01

    40 lactating cows were fed either clovergrass or maize silage and a low or high dietary energy concentration in a 2x2 factorial design. The maize silage diets rich in starch and linoleic acid resulted in a higher content of c9t11 and t10c12 CLA in milk fat than the grass silage diets. A high energy...... concentration plus maize silage led to a pronounced shift in the biohydrogenation pathway of linoleic acid, the highest t10c12 CLA content and lowest milk fat percentage. Energy concentration had no effect on milk fat CLA content or milk fat percentage in grass silage fed cows....

  8. Cooking decreases observed perfluorinated compound concentrations in fish.

    Science.gov (United States)

    Del Gobbo, Liana; Tittlemier, Sheryl; Diamond, Miriam; Pepper, Karen; Tague, Brett; Yeudall, Fiona; Vanderlinden, Loren

    2008-08-27

    Dietary intake is a major route of exposure to perfluorinated compounds (PFCs). Although fish and seafood contribute significantly to total dietary exposure to these compounds, there is uncertainty with respect to the effect of cooking on PFC concentrations in these foods. Eighteen fish species purchased from markets in Toronto, Mississauga, and Ottawa, Canada were analyzed for perfluorooctanesulfonamide (PFOSAs)-based fluorochemicals and perfluorinated acids (PFAs) in raw and cooked (baked, boiled, fried) samples. Of 17 analytes, perfluorooctanesulfonic acid (PFOS) was detected most frequently; concentrations ranged from 0.21 to 1.68 ng/g ww in raw and cooked samples. PFOSAs were detected only in scallops at concentrations ranging from 0.20 ng/g ww to 0.76 ng/g ww. Total concentrations of PFAs in samples were 0.21 to 9.20 ng/g ww, respectively, consistent with previous studies. All cooking methods reduced PFA concentrations. Baking appeared to be the most effective cooking method; after baking samples for 15 min at 163 C (325 degrees F), PFAs were not detected in any of the samples. The margin of exposures (MOE) between the toxicological points of reference and the dietary intake of perfluorocarboxylates (PFCAs) and PFOS in fish and seafood muscle tissue were greater than 4 orders of magnitude. This indicates that reducing consumption of fish muscle tissue is not warranted on the basis of PFC exposure concerns at the reported levels of contamination, even for high fish consuming populations.

  9. The evaluation and quantification of respirable coal and silica dust concentrations: a task-based approach.

    Science.gov (United States)

    Grové, T; Van Dyk, T; Franken, A; Du Plessis, J

    2014-01-01

    Silicosis and coal worker's pneumoconiosis are serious occupational respiratory diseases associated with the coal mining industry and the inhalation of respirable dusts containing crystalline silica. The purpose of this study (funded by the Mine Health and Safety Council of South Africa) was to evaluate the individual contributions of underground coal mining tasks to the respirable dust and respirable silica dust concentrations in an underground section by sampling the respirable dust concentrations at the intake and return of each task. The identified tasks were continuous miner (CM) cutting, construction, transfer of coal, tipping, and roof bolting. The respirable dust-generating hierarchy of the tasks from highest to lowest was: transfer of coal > CM right cutting > CM left cutting > CM face cutting > construction > roof bolting > tipping; and for respirable silica dust: CM left cutting > construction > transfer of coal > CM right cutting. Personal exposure levels were determined by sampling the exposures of workers performing tasks in the section. Respirable dust concentrations and low concentrations of respirable silica dust were found at the intake air side of the section, indicating that air entering the section is already contaminated. The hierarchy for personal respirable dust exposures was as follows, from highest to lowest: CM operator > cable handler > miner > roof bolt operator > shuttle car operator, and for respirable silica dust: shuttle car operator > CM operator > cable handler > roof bolt operator > miner. Dust control methods to lower exposures should include revision of the position of workers with regard to the task performed, positioning of the tasks with regard to the CM cutting, and proper use of the line curtains to direct ventilation appropriately. The correct use of respiratory protection should also be encouraged.

  10. Detection Limits Of The 125I Air Sampler ''RIS125''

    International Nuclear Information System (INIS)

    Belaish, I.; Levinson, S.; German, U.; Kravchik, T.

    1999-01-01

    A system for 125 I monitoring in air (RIS-125) was designed and manufactured at NRCN. The main features of the system are described elsewhere. The system can monitor 125 I air contamination in gaseous and aerosol forms. An air monitoring system should have a fast response and the lowest available Minimum Detectable Activity (MDA). The present work presents the characteristic MDA values of the system

  11. The association between soya consumption and serum thyroid-stimulating hormone concentrations in the Adventist Health Study-2.

    Science.gov (United States)

    Tonstad, Serena; Jaceldo-Siegl, Karen; Messina, Mark; Haddad, Ella; Fraser, Gary E

    2016-06-01

    Consumers may choose soya foods as healthful alternatives to animal products, but concern has arisen that eating large amounts of soya may adversely affect thyroid function. The present study aimed to examine the association between soya food consumption and serum thyroid-stimulating hormone (TSH) concentrations in North American churchgoers belonging to the Seventh-day Adventist denomination that encourages vegetarianism. Participants completed six repeated 24 h dietary recalls within a 6-month period. Soya protein and soya isoflavone intakes were estimated, and their relationships to TSH concentrations measured at the end of 6 months were calculated using logistic regression analyses. Calibration sub-study of the Adventist Health Study-2. Women (n 548) and men (n 295) who were not taking thyroid medications. In men, age and urinary iodine concentrations were associated with high serum TSH concentrations (>5 mIU/l), while among women White ethnicity was associated with high TSH. In multivariate models adjusted for age, ethnicity and urinary iodine, soya isoflavone and protein intakes were not associated with high TSH in men. In women higher soya isoflavone consumption was associated with higher TSH, with an adjusted odds ratio (highest v. lowest quintile) of 4·17 (95 % CI 1·73, 10·06). Likewise, women with high consumption of soya protein (midpoint of highest quintile, 11 g/d) v. low consumption (midpoint of lowest quintile, 0 g/d) carried increased odds of high TSH (OR=2·69; 95 % CI 1·34, 5·30). In women high consumption of soya was associated with elevated TSH concentrations. No associations between soya intake and TSH were found in men.

  12. Fluorine concentration profiles in archaeological bone

    International Nuclear Information System (INIS)

    Coote, G.E.; Sparks, R.J.

    1981-01-01

    The nuclear microprobe at the Institute of Nuclear Sciences was applied to the measurement of radial concentration profiles of fluorine, in transverse slices of archaeological bone from humans, moas, and other animals. A beam of 2.5 MeV protons was focused to a rectangular spot 250 microns by 50 microns, traversed along a radial line 3mm long, and gamma rays of 5-7 MeV from the reaction 19 F(p, α#betta#) 16 O were detected in a large sodium iodide crystal. Bombardment caused no detectable loss of fluorine from the bone. Measured profiles display a wide variety of shapes and maximum concentrations. In bones which had been exposed to ground water the fluorine concentration usually increases from the centre towards the surface, sometimes by as much as a factor of eight. The concentration at the surface is usually in the range 0.2 to 1%, though in moa bone from a limestone cave it is only 0.025%. Once a quantitative method of analysis has been developed, based on the shape of the profile rather than its magnitude, these profiles might be useful for dating bone. In the meantime, they could be used to distinguish bones of different ages from a common site

  13. Airborne Precursors Predict Maternal Serum Perfluoroalkyl Acid Concentrations.

    Science.gov (United States)

    Makey, Colleen M; Webster, Thomas F; Martin, Jonathan W; Shoeib, Mahiba; Harner, Tom; Dix-Cooper, Linda; Webster, Glenys M

    2017-07-05

    Human exposure to persistent perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorooctanesulfonate (PFOS), can occur directly from contaminated food, water, air, and dust. However, precursors to PFAAs (PreFAAs), such as dipolyfluoroalkyl phosphates (diPAPs), fluorotelomer alcohols (FTOHs), perfluorooctyl sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs), which can be biotransformed to PFAAs, may also be a source of exposure. PFAAs were analyzed in 50 maternal sera samples collected in 2007-2008 from participants in Vancouver, Canada, while PFAAs and PreFAAs were measured in matching samples of residential bedroom air collected by passive sampler and in sieved vacuum dust (<150 μm). Concentrations of PreFAAs were higher than for PFAAs in air and dust. Positive associations were discovered between airborne 10:2 FTOH and serum PFOA and PFNA and between airborne MeFOSE and serum PFOS. On average, serum PFOS concentrations were 2.3 ng/mL (95%CI: 0.40, 4.3) higher in participants with airborne MeFOSE concentrations in the highest tertile relative to the lowest tertile. Among all PFAAs, only PFNA in air and vacuum dust predicted serum PFNA. Results suggest that airborne PFAA precursors were a source of PFOA, PFNA, and PFOS exposure in this population.

  14. Optics of Confined Liquid Crystals for Gas Detection

    Science.gov (United States)

    Charles, William; Carrozzi, Daniel; Vigilia, Lee Anne; Wang, Xiaoyurui; Guzman, Violet; Shibayev, Petr; Fordham University Students of Undergraduate Physics Team

    Cholesteric liquid crystals (CLCs) of a wide range of viscosities were studied experimentally in relation to their use as gas sensors and sensors of volatile organic compounds (VOCs), specifically ethanol, cyclohexane, toluene, acetic acid, and pyridine. CLCs were obtained by mixing low molar mass liquid crystals (MBBA and cholesterol derivatives with siloxane based oligomers). The droplets of CLCs were placed in containers with controlled atmospheres. The shift of the selective reflection band, predominantly from shorter to longer wavelengths, and the color changes were observed in the CLC illuminated by light coming from the various directions. Visible optical changes were observed in droplets with viscosities of CLCs ranging from c.a. 4 Pa*s to 105 Pa*s. The most responsive droplets in which the shift of the selective reflection band occurs at lower concentrations of VOCs were prepared from CLC mixtures with the lowest viscosities. Higher viscosities of CLCs lead to a slower response to VOCs, but the rate of response is different for each pair of VOC and CLC with a certain viscosity. This finding opens a possibility for selective detection of VOCs by CLCs with different viscosities. The mechanism of VOCs diffusion, interaction with CLC matrix and optical changes is discusse

  15. Development of mediator-type biosensor to wirelessly monitor whole cholesterol concentration in fish.

    Science.gov (United States)

    Takase, Mai; Murata, Masataka; Hibi, Kyoko; Huifeng, Ren; Endo, Hideaki

    2014-04-01

    We developed a wireless monitoring system to monitor fish condition by tracking the change in whole cholesterol concentration. The whole cholesterol concentration of fish is a source of steroid hormones or indicator of immunity level, which makes its detection important for tracking physiological condition of fish. Wireless monitoring system comprises of mediator-type biosensor and wireless transmission device. Biosensor is implantable to fish body, and transmission device is so light, in that fish is allowed to swim freely during monitoring. Cholesterol esterase and oxidase were fixated on to the detection site of biosensor and used to detect the whole cholesterol concentration. However, cholesterol oxidase incorporates oxidation-reduction reaction of oxygen for detection, which concentration fluctuates easily due to change in environmental condition. Meanwhile, mediator-type biosensor enables monitoring of whole cholesterol concentration by using mediator to substitute that oxidation-reduction reaction of oxygen. Characteristic of fabricated mediator-type biosensor was tested. The sensor output current of mediator-type biosensor remained stable compared to output current of non-mediator-type biosensor under fluctuating oxygen concentration of 0-8 ppm, which implied that this sensor is less affected by change in dissolved oxygen concentration. That biosensor was then implanted into fish for wireless monitoring. As a result, approximately 48 h of real-time monitoring was successful.

  16. Improved optical properties and detectivity of an uncooled silicon carbide mid-wave infrared optical detector with increased dopant concentration

    International Nuclear Information System (INIS)

    Lim, Geunsik; Kar, Aravinda; Manzur, Tariq

    2012-01-01

    An n-type 4H-SiC substrate is doped with gallium using a laser doping technique and its optical response is investigated at the mid-wave infrared (MWIR) wavelength 4.21 μm as a function of the dopant concentration. The dopant creates a p-type energy level of 0.3 eV, which is the energy of a photon corresponding to the MWIR wavelength 4.21 μm. Therefore, Ga-doped SiC can be used as an uncooled MWIR detector because an optical signal was obtained at this wavelength when the sample was at room temperature. The energy level of the Ga dopant in the substrate was confirmed by optical absorption spectroscopy. Secondary ion mass spectroscopy (SIMS) of the doped samples revealed an enhancement in the solid solubility of Ga in the substrate when doping is carried out by increasing the number of laser scans. A higher dopant concentration increases the number of holes in the dopant energy level, enabling photoexcitation of more electrons from the valence band by the incident MWIR photons. The detector performance improves as the dopant concentration increases from 1.15 × 10 19 to 6.25 × 10 20 cm −3 . The detectivity of the optical photodetector is found to be 1.07 × 10 10 cm Hz 1/2 W −1 for the case of doping with four laser passes. (paper)

  17. Direct observation of the lowest indirect exciton state in the bulk of hexagonal boron nitride

    Science.gov (United States)

    Schuster, R.; Habenicht, C.; Ahmad, M.; Knupfer, M.; Büchner, B.

    2018-01-01

    We combine electron energy-loss spectroscopy and first-principles calculations based on density-functional theory (DFT) to identify the lowest indirect exciton state in the in-plane charge response of hexagonal boron nitride (h-BN) single crystals. This remarkably sharp mode forms a narrow pocket with a dispersion bandwidth of ˜100 meV and, as we argue based on a comparison to our DFT calculations, is predominantly polarized along the Γ K direction of the hexagonal Brillouin zone. Our data support the recent report by Cassabois et al. [Nat. Photonics 10, 262 (2016), 10.1038/nphoton.2015.277] who indirectly inferred the existence of this mode from the photoluminescence signal, thereby establishing h-BN as an indirect semiconductor.

  18. Natural and anthropogenic radionuclide activity concentrations in the New Zealand diet

    International Nuclear Information System (INIS)

    Pearson, Andrew J.; Gaw, Sally; Hermanspahn, Nikolaus; Glover, Chris N.

    2016-01-01

    To support New Zealand's food safety monitoring regime, a survey was undertaken to establish radionuclide activity concentrations across the New Zealand diet. This survey was undertaken to better understand the radioactivity content of the modern diet and also to assess the suitability of the current use of milk as a sentinel for dietary radionuclide trends. Thirteen radionuclides were analysed in 40 common food commodities, including animal products, fruits, vegetables, cereal grains and seafood. Activity was detected for 137 Caesium, 90 Strontium and 131 Iodine. No other anthropogenic radionuclides were detected. Activity concentrations of the three natural radionuclides of Uranium and the daughter radionuclide 210 Polonium were detected in the majority of food sampled, with a large variation in magnitude. The maximum activity concentrations were detected in shellfish for all these radionuclides. Based on the established activity concentrations and ranges, the New Zealand diet contains activity concentrations of anthropogenic radionuclides far below the Codex Alimentarius guideline levels. Activity concentrations obtained for milk support its continued use as a sentinel for monitoring fallout radionuclides in terrestrial agriculture. The significant levels of natural and anthropogenic radionuclide activity concentrations detected in finfish and molluscs support undertaking further research to identify a suitable sentinel for New Zealand seafood monitoring. - Highlights: • A radionuclide monitoring program was undertaken across the New Zealand food supply. • 40 food types were analysed for 13 radionuclides. • 137 Cs was present in 15% of foods (range: 0.05–0.44Bq/kg). • Anthropogenic radionuclides displayed compliance with international limits. • 210 Po, 234 U and 238 U were present in most foods with large ranges of activities.

  19. Detection of saliva-range glucose concentrations using organic thin-film transistors

    International Nuclear Information System (INIS)

    Elkington, D.; Belcher, W. J.; Dastoor, P. C.; Zhou, X. J.

    2014-01-01

    We describe the development of a glucose sensor through direct incorporation of an enzyme (glucose oxidase) into the gate of an organic thin film transistor (OTFT). We show that glucose diffusion is the key determinant of the device response time and present a mechanism of glucose sensing in these devices that involves protonic doping of the transistor channel via enzymatic oxidation of glucose. The integrated OTFT sensor is sensitive across 4 decades of glucose concentration; a range that encompasses both the blood and salivary glucose concentration levels. As such, this work acts as a proof-of-concept for low-cost printed biosensors for salivary glucose.

  20. Detection of saliva-range glucose concentrations using organic thin-film transistors

    Energy Technology Data Exchange (ETDEWEB)

    Elkington, D.; Belcher, W. J.; Dastoor, P. C.; Zhou, X. J. [Centre for Organic Electronics, University of Newcastle, Callaghan, New South Wales 2308 (Australia)

    2014-07-28

    We describe the development of a glucose sensor through direct incorporation of an enzyme (glucose oxidase) into the gate of an organic thin film transistor (OTFT). We show that glucose diffusion is the key determinant of the device response time and present a mechanism of glucose sensing in these devices that involves protonic doping of the transistor channel via enzymatic oxidation of glucose. The integrated OTFT sensor is sensitive across 4 decades of glucose concentration; a range that encompasses both the blood and salivary glucose concentration levels. As such, this work acts as a proof-of-concept for low-cost printed biosensors for salivary glucose.

  1. Mercury, cadmium and lead concentrations in different ecophysiological groups of earthworms in forest soils

    International Nuclear Information System (INIS)

    Ernst, Gregor; Zimmermann, Stefan; Christie, Peter; Frey, Beat

    2008-01-01

    Bioaccumulation of Hg, Cd and Pb by eight ecophysiologically distinct earthworm species was studied in 27 polluted and uncontaminated forest soils. Lowest tissue concentrations of Hg and Cd occurred in epigeic Lumbricus rubellus and highest in endogeic Octolasion cyaneum. Soils dominated by Dendrodrilus rubidus possess a high potential of risk of Pb biomagnification for secondary predators. Bioconcentration factors (soil-earthworm) followed the sequence ranked Cd > Hg > Pb. Ordination plots of redundancy analysis were used to compare HM concentrations in earthworm tissues with soil, leaf litter and root concentrations and with soil pH and CEC. Different ecological categories of earthworms are exposed to Hg, Cd and Pb in the topsoil by atmospheric deposition and accumulate them in their bodies. Species differences in HM concentrations largely reflect differences in food selectivity and niche separation. - Accumulation of non-essential heavy metals by earthworms is species-dependent and is affected by soil characteristics in natural forest soils

  2. High-resolution carbon dioxide concentration record 650,000-800,000 years before present

    DEFF Research Database (Denmark)

    Lüthi, Dieter; Le Floch, Martine; Bereiter, Bernhard

    2008-01-01

    Changes in past atmospheric carbon dioxide concentrations can be determined by measuring the composition of air trapped in ice cores from Antarctica. So far, the Antarctic Vostok and EPICA Dome C ice cores have provided a composite record of atmospheric carbon dioxide levels over the past 650......,000 years. Here we present results of the lowest 200 m of the Dome C ice core, extending the record of atmospheric carbon dioxide concentration by two complete glacial cycles to 800,000 yr before present. From previously published data and the present work, we find that atmospheric carbon dioxide...... is strongly correlated with Antarctic temperature throughout eight glacial cycles but with significantly lower concentrations between 650,000 and 750,000 yr before present. Carbon dioxide levels are below 180 parts per million by volume (p.p.m.v.) for a period of 3,000 yr during Marine Isotope Stage 16...

  3. Entry of Nd+3 ions into the LiYF4 matrix and determination of Nd+3 concentration by the nondestructing spectrophotometric method

    International Nuclear Information System (INIS)

    Tkachuk, A.M.; Poletimova, A.V.; Petrova, M.A.; Egorov, V.Yu.; Korolev, N.E.

    1991-01-01

    Entering of Nd 3+ ions into LiYF 4 lattice was investigation. Nondestructive spectrophotometric method for determining activator concentration in the crystal was developed. It enables to determine both the average integral concentration in the active element. Absorption cross sections were determined for a series of reference lines λ i with the lowest polarization degree. Values of β(λ i ) coefficients, enabling to determine the average neodymium concentration in the sample, are presented. Coefficient of neodymium entering into LiYF 4 lattice was determined: K nd =0.31+-0.02

  4. Detecting terrestrial nutrient limitation: a global meta-analysis of foliar nutrient concentrations after fertilization

    Directory of Open Access Journals (Sweden)

    Rebecca eOstertag

    2016-03-01

    Full Text Available Examining foliar nutrient concentrations after fertilization provides an alternative method for detecting nutrient limitation of ecosystems, which is logistically simpler to measure than biomass change. We present a meta-analysis of response ratios of foliar nitrogen and phosphorus (RRN, RRP after addition of fertilizer of nitrogen (N, phosphorus (P, or the two elements in combination, in relation to climate, ecosystem type, life form, family, and methodological factors. Results support other meta-analyses using biomass, and demonstrate there is strong evidence for nutrient limitation in natural communities. However, because N fertilization experiments greatly outnumber P fertilization trials, it is difficult to discern the absolute importance of N vs. P vs. co-limitation across ecosystems. Despite these caveats, it is striking that results did not follow conventional wisdom that temperate ecosystems are N-limited and tropical ones are P-limited. In addition, the use of ratios of N-to-P rather than response ratios also are a useful index of nutrient limitation, but due to large overlap in values, there are unlikely to be universal cutoff values for delimiting N vs. P limitation. Differences in RRN and RRP were most significant across ecosystem types, plant families, life forms, and between competitive environments, but not across climatic variables.

  5. Optimal serum selenium concentrations are associated with lower depressive symptoms and negative mood among young adults.

    Science.gov (United States)

    Conner, Tamlin S; Richardson, Aimee C; Miller, Jody C

    2015-01-01

    There is evidence that low, and possibly high, selenium status is associated with depressed mood. More evidence is needed to determine whether this pattern occurs in young adults with a wide range of serum concentrations of selenium. The aim of this study was to determine if serum selenium concentration is associated with depressive symptoms and daily mood states in young adults. A total of 978 young adults (aged 17-25 y) completed the Center for Epidemiological Studies-Depression scale and reported their negative and positive mood daily for 13 d using an Internet diary. Serum selenium concentration was determined by inductively coupled plasma mass spectrometry. ANCOVA and regression models tested the linear and curvilinear associations between decile of serum selenium concentration and mood outcomes, controlling for age, gender, ethnicity, BMI, and weekly alcohol intake. Smoking and childhood socioeconomic status were further controlled in a subset of participants. The mean ± SD serum selenium concentration was 82 ± 18 μg/L and ranged from 49 to 450 μg/L. Participants with the lowest serum selenium concentration (62 ± 4 μg/L; decile 1) and, to a lesser extent, those with the highest serum selenium concentration (110 ± 38 μg/L; decile 10) had significantly greater adjusted depressive symptoms than did participants with midrange serum selenium concentrations (82 ± 1 to 85 ± 1 μg/L; deciles 6 and 7). Depressive symptomatology was lowest at a selenium concentration of ∼85 μg/L. Patterns for negative mood were similar but more U-shaped. Positive mood showed an inverse U-shaped association with selenium, but this pattern was less consistent than depressive symptoms or negative mood. In young adults, an optimal range of serum selenium between ∼82 and 85 μg/L was associated with reduced risk of depressive symptomatology. This range approximates the values at which glutathione peroxidase is maximal, suggesting that future research should investigate

  6. Metals in the Scheldt estuary: From environmental concentrations to bioaccumulation.

    Science.gov (United States)

    Van Ael, Evy; Blust, Ronny; Bervoets, Lieven

    2017-09-01

    To investigate the relationship between metal concentrations in abiotic compartments and in aquatic species, sediment, suspended matter and several aquatic species (Polychaeta, Oligochaeta, four crustacean species, three mollusc species and eight fish species) were collected during three seasons at six locations along the Scheldt estuary (the Netherlands-Belgium) and analysed on their metal content (Ag, Cd, Co, Cr, Cu, Ni, Pb, Zn and the metalloid As). Sediment and biota tissue concentrations were significantly influenced by sampling location, but not by season. Measurements of Acid Volatile Sulphides (AVS) concentrations in relation to Simultaneously Extracted Metals (SEM) in the sediment suggested that not all metals in the sediment will be bound to sulphides and some metals might be bioavailable. For all metals but zinc, highest concentrations were measured in invertebrate species; Ag and Ni in periwinkle, Cr, Co and Pb in Oligochaete worms and As, Cd and Cu in crabs and shrimp. Highest concentrations of Zn were measured in the kidney of European smelt. In fish, for most of the metals, the concentrations were highest in liver or kidney and lowest in muscle. For Zn however, highest concentrations were measured in the kidney of European smelt. For less than half of the metals significant correlations between sediment metal concentrations and bioaccumulated concentrations were found (liver/hepatopancreas or whole organism). To calculate the possible human health risk by consumption, average and maximum metal concentrations in the muscle tissues were compared to the minimum risk levels (MRLs). Concentrations of As led to the highest risk potential for all consumable species. Cadmium and Cu posed only a risk when consuming the highest contaminated shrimp and shore crabs. Consuming blue mussel could result in a risk for the metals As, Cd and Cr. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. HH 1158: THE LOWEST LUMINOSITY EXTERNALLY IRRADIATED HERBIG–HARO JET

    International Nuclear Information System (INIS)

    Riaz, B.; Whelan, E. T.

    2015-01-01

    We have identified a new externally irradiated Herbig–Haro (HH) jet, HH 1158, within ∼2 pc of the massive OB type stars in the σ Orionis cluster. At an L bol  ∼ 0.1 L ⊙ , HH 1158 is the lowest luminosity irradiated HH jet identified to date in any cluster. Results from the analysis of high-resolution optical spectra indicate asymmetries in the brightness, morphology, electron density, velocity, and the mass outflow rates for the blue and redshifted lobes. We constrain the position angle of the HH 1158 jet at 102° ± 5°. The mass outflow rate and the mean accretion rate for HH 1158 using multiple diagnostics are estimated to be (5.2 ± 2.6) × 10 −10 M ⊙ yr −1 and (3.0 ± 1.0) × 10 −10 M ⊙ yr −1 , respectively. The properties for HH 1158 are notably similar to the externally irradiated HH 444–HH 447 jets previously identified in σ Orionis. In particular, the morphology is such that the weaker jet beam is tilted toward the massive stars, indicating a higher extent of photo-evaporation. The high value for the Hα/[S ii] ratio is also consistent with the ratios measured in other irradiated jets, including HH 444–HH 447. The presence of an extended collimated jet that is bipolar and the evidence of shocked emission knots make HH 1158 the first unique case of irradiated HH jets at the very low-luminosity end, and provides an opportunity to learn the physical properties of very faint HH jet sources

  8. Concentration of mercury and selenium in tissues of five cetacean species from Croatian coastal waters

    Directory of Open Access Journals (Sweden)

    Bilandžić Nina

    2015-01-01

    Full Text Available Mercury (Hg and selenium (Se concentrations were measured in muscle, liver, kidney, spleen and lung tissues of five cetacean species, three dolphin (Stenella coeruleoalba, Tursiops truncatus and Grampus griseus and two whale species (Balaenoptera physalus and Ziphius cavirostris, stranded along the Croatian coast during the period 1999-2002. Statistically significant differences in Hg concentrations in muscle, spleen and lung, and Se in liver and lung of the different dolphin species were observed. Mercury levels in liver and spleen and Se levels in liver differed between young and adult T. truncatus species. A significant positive correlation between different tissue types for Hg and Se concentrations was observed. In all tissues tested, the lowest Hg and Se concentrations were found in B. physalus. Mercury concentrations were positively correlated with Se in all tissues. The results present one of few studies related to lung and spleen tissues in these mammals, particularly in the Adriatic Sea. Since very little data are available, this research provides new data on concentrations of Hg and Se in five cetacean species from the Adriatic Sea basin.

  9. Varying hemin concentrations affect Porphyromonas gingivalis strains differently.

    Science.gov (United States)

    Ohya, Manabu; Cueno, Marni E; Tamura, Muneaki; Ochiai, Kuniyasu

    2016-05-01

    Porphyromonas gingivalis requires heme to grow, however, heme availability and concentration in the periodontal pockets vary. Fluctuations in heme concentration may affect each P. gingivalis strain differently, however, this was never fully demonstrated. Here, we elucidated the effects of varying hemin concentrations in representative P. gingivalis strains. Throughout this study, representative P. gingivalis strains [FDC381 (type I), MPWIb-01 (type Ib), TDC60 (type II), ATCC49417 (type III), W83 (type IV), and HNA99 (type V)] were used and grown for 24 h in growth media under varying hemin concentrations (5 × , 1 × , 0.5 × , 0.1 × ). Samples were lysed and protein standardized. Arg-gingipain (Rgp), H2O2, and superoxide dismutase (SOD) levels were subsequently measured. We focused our study on 24 h-grown strains which excluded MPWIb-01 and HNA99. Rgp activity among the 4 remaining strains varied with Rgp peaking at: 1 × for FDC381, 5 × for TDC60, 0.5 × for ATCC49417, 5 × and 0.5 × for W83. With regards to H2O2 and SOD amounts: FDC381 had similar H2O2 amounts in all hemin concentrations while SOD levels varied; TDC60 had the lowest H2O2 amount at 1 × while SOD levels became higher in relation to hemin concentration; ATCC49417 also had similar H2O2 amounts in all hemin concentrations while SOD levels were higher at 1 × and 0.5 × ; and W83 had statistically similar H2O2 and SOD amounts regardless of hemin concentration. Our results show that variations in hemin concentration affect each P. gingivalis strain differently. Published by Elsevier Ltd.

  10. Comparison of Attenuation of petroleum hydrocarbons in surface ...

    African Journals Online (AJOL)

    These concentrations further changed at day 56 with the non amended soils now having the lowest TPH concentrations. 56 days after spiking with TPH, only the C 10 – C 12 and > C16 carbon number fractions were detected at both depths. Results suggest that natural attenuation can be a viable remediation strategy in ...

  11. Poly(zwitterionic liquids) functionalized polypyrrole/graphene oxide nanosheets for electrochemically detecting dopamine at low concentration

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Hui; Liang, Jiachen; Ji, Chunguang; Zhang, Haifeng; Pei, Qi; Zhang, Yuyang; Zhang, Yu [Liaoning Key Laboratory for Green Synthesis and Preparative Chemistry of Advanced Materials, College of Chemistry, Liaoning University, Shenyang 110036 (China); Hisaeda, Yoshio [Department of Chemistry and Biochemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Song, Xi-Ming, E-mail: songlab@lnu.edu.cn [Liaoning Key Laboratory for Green Synthesis and Preparative Chemistry of Advanced Materials, College of Chemistry, Liaoning University, Shenyang 110036 (China); Department of Chemistry and Biochemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-08-01

    Poly(3-(1-vinylimidazolium-3-yl)propane-1-sulfonate) (PVIPS), a novel kind of poly(zwitterionic liquids) (PZILs) containing both imidazolium cation and sulfonate anion, was successfully modified on the surface of polypyrrole/graphene oxide nanosheets (PPy/GO) by covalent bonding. The obtained novel PZILs functionalized PPy/GO nanosheets (PVIPS/PPy/GO) modified glassy carbon electrode (GCE) presented the excellent electrochemical catalytic activity towards dopamine (DA) with high stability, sensitivity, selectivity and wide linear range (40–1220 nM), especially having a lower detection limit (17.3 nM). The excellent analytical performance is attributed to the strongly negative charges on the surface of modified GCE in aqueous solution, which is different from conventional poly(ionic liquids) modified GCE. DA cations could be quickly enriched on the electrode surface by electrostatic interaction in solution due to the existence of −SO{sub 3}{sup −} groups with negative charge at the end of pendant groups in zwitterionic PVIPS, resulting in a change of the electrons transmission mode in the oxidation of DA, that is, from a typical diffusion-controlled process at conventional poly(1-vinyl-3-ethylimidazole bromide) (PVEIB)/PPy/GO modified GCE to a typical surface-controlled process. - Graphical Abstract: Novel poly(zwitterionic liquids) functionalized polypyrrole/graphene oxide nanosheets were successfully synthesized and presented an excellent performance for determination to DA. Display Omitted - Highlights: • Zwitterionic PVIPS functionalized PPy/GO nanosheets were successfully synthesized. • Their surface charge property has been obviously changed to electronegativity. • The excellent electrochemical catalytic activities towards DA were achieved. • −SO{sub 3}{sup −} groups with negative charge changed the transmission mode of electrons. • PVIPS/PPy/GO can act as an electrode material for detecting DA at low concentration.

  12. Magnetic moments of the lowest-lying singly heavy baryons

    Science.gov (United States)

    Yang, Ghil-Seok; Kim, Hyun-Chul

    2018-06-01

    A light baryon is viewed as Nc valence quarks bound by meson mean fields in the large Nc limit. In much the same way a singly heavy baryon is regarded as Nc - 1 valence quarks bound by the same mean fields, which makes it possible to use the properties of light baryons to investigate those of the heavy baryons. A heavy quark being regarded as a static color source in the limit of the infinitely heavy quark mass, the magnetic moments of the heavy baryon are determined entirely by the chiral soliton consisting of a light-quark pair. The magnetic moments of the baryon sextet are obtained by using the parameters fixed in the light-baryon sector. In this mean-field approach, the numerical results of the magnetic moments of the baryon sextet with spin 3/2 are just 3/2 larger than those with spin 1/2. The magnetic moments of the bottom baryons are the same as those of the corresponding charmed baryons.

  13. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Science.gov (United States)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO2) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO2 and HHb, total haemoglobin concentration and SO2. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l-1 (±58 µM) and ±4

  14. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Energy Technology Data Exchange (ETDEWEB)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London WC1E 6BT (United Kingdom)

    2007-01-07

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO{sub 2}) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO{sub 2}) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO{sub 2} and HHb, total haemoglobin concentration and SO{sub 2}. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of {+-}3

  15. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    International Nuclear Information System (INIS)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO 2 ) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO 2 ) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO 2 and HHb, total haemoglobin concentration and SO 2 . The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l -1 (±58

  16. Some methods for the detection of fissionable matter; Quelques methodes de detection des corps fissiles

    Energy Technology Data Exchange (ETDEWEB)

    Guery, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-03-01

    A number of equipments or processes allowing to detect uranium or plutonium in industrial plants, and in particular to measure solution concentrations, are studied here. Each method has its own field of applications and has its own performances, which we have tried to define by calculations and by experiments. The following topics have been treated: {gamma} absorptiometer with an Am source, detection test by neutron multiplication, apparatus for the measurement of the {alpha} activity of a solution, fissionable matter detection by {gamma} emission, fissionable matter detection by neutron emission. (author) [French] On examine ici plusieurs appareils ou procedes qui permettent de detecter l'uranium ou le plutonium dans les installations industrielles, et en particulier de mesurer les concentrations de solutions. Chacune des methodes a son domaine d'application et ses performances, qu'on a tente de definir par le calcul et par des experiences. Les sujets traites sont les suivants: absorptiometre {gamma} a source d'americium, essais de detection par multiplication neutronique, appareil de mesure de l'activite {alpha} d'une solution, detection des matieres fissiles par leur emission {gamma}, detection des matieres fissiles par leur emission neutronique. (auteur)

  17. Detection of macrophages in rabbit semen and their relationship with semen quality.

    Science.gov (United States)

    Kuželová, Lenka; Vašíček, Jaromír; Rafay, Ján; Chrenek, Peter

    2017-07-15

    We aimed at the evaluating the occurrence of macrophages in rabbit semen and finding possible relationship between macrophage concentration and spermatozoa quality. The concentration of macrophages in semen samples from broiler rabbit males of lines M91 and P91 (n = 30) without overt evidence of genital tract infections was determined using monocyte/macrophage lineage antigen CD14 and flow cytometry. Then the rabbits were assigned into three groups according to the macrophage concentration in semen (MΦ1 group with less than 1 × 10 6 macrophages/mL, MΦ2 group with 1.5-3.5 × 10 6 macrophages/mL and MΦ3 group with more than 8 × 10 6 macrophages/mL). Spermatozoa viability parameters such as occurrence of apoptotic (Yo-Pro-1) and dead/necrotic (propidium iodide) spermatozoa and plasma membrane integrity (PNA-Fluos) were evaluated using flow cytometry. Sperm motility parameters were determined by CASA (Computer Assisted Semen Analysis). Ultrastructural detection of macrophages was performed using transmission electron microscopy. Spermatozoa fertility potential was examined after intravaginal artificial insemination of rabbit doses. Significantly higher proportions of the apoptotic and necrotic spermatozoa and spermatozoa with lower plasma membrane integrity were revealed in the MΦ3 group compared to MΦ1 and MΦ2 groups. The percentage value of total motility and progressive movement was significantly highest in the MΦ1 group, whilst lowest in the MΦ3 group. The conception rate and the kindling rate were significantly decreased in the group with the highest macrophage concentration (MΦ3). Based on our results we can conclude that the abundance of seminal macrophages in the rabbit semen may be closely associated with poor spermatozoa quality. Copyright © 2017. Published by Elsevier Inc.

  18. Mercury concentrations in the coastal marine food web along the Senegalese coast.

    Science.gov (United States)

    Diop, Mamadou; Amara, Rachid

    2016-06-01

    This paper presents the results of seasonal (wet and dry seasons) and spatial (five sites) variation of mercury concentration in seven marine organisms representative for shallow Senegalese coastal waters and including species of commercial importance. Total mercury levels were recorded in the green algae (Ulva lactuca); the brown mussel (Perna perna); the Caramote prawn (Penaeus kerathurus); and in the liver and muscles of the following fish: Solea senegalensis, Mugil cephalus, Saratherondon melanotheron, and Sardinella aurita. The total selenium (Se) contents were determined only in the edible part of Perna perna, Penaeus kerathurus and in the muscles of Sardinella aurita and Solea senegalensis. Hg concentration in fish species was higher in liver compared to the muscle. Between species differences in Hg, concentrations were recorded with the highest concentration found in fish and the lowest in algae. The spatiotemporal study showed that there was no clear seasonal pattern in Hg concentrations in biota, but spatial differences existed with highest concentrations in sites located near important anthropogenic pressure. For shrimp, mussel, and the muscles of sardine and sole, Hg concentrations were below the health safety limits for human consumption as defined by the European Union. The Se/Hg molar ratio was always higher than one whatever the species or location suggesting a protection of Se against Hg potential adverse effect.

  19. Is increasing industrialization affecting remote ecosystem health in the South Americas? Insights from ocean surface water measurements of As, Sb and Pb from a GEOTRACES transect

    Science.gov (United States)

    Weiss, Dominik; Salaun, Pascal; Van den Berg, Stan; Bi, Zaoshun

    2014-05-01

    Continued industrial development of the South Americas with increasing atmospheric emission of toxic trace metals has lead to a growing concern about possible effects on pristine ecosystem health. Concentration measurements of trace metals in ocean surface waters in the North Atlantic have successfully revealed the global extent of atmospheric pollution in the Northern Hemisphere during economical growth in the USA and Europe, suggesting a similar approach can be applied to the Southern Hemisphere. To this end, we determined concentrations of lead (Pb), antimony (Sb) and arsenic (As) using voltammetry in surface water samples of the South Atlantic Ocean collected during the third leg of the GEOTRACES West Atlantic Cruise. These elements are volatile and therefore most likely suitable tracer elements of industrial emissions from South America. The samples were not filtered and the solutions were acidified and UV digested. Total concentrations of Pb were detected. Detected As levels correspond to the sum of inorganic species (AsIII + AsV) plus the mono methyl arsenic acid (MMA) while the dimethyl arsenic acid (DMA) is not detected in such conditions. For Sb, detected levels correspond at least to the sum of inorganic fractions (SbIII + SbV). The measured concentrations for Pb varied from 6 to 23 pM. Concentrations were highest at -35° latitude and lowest at -40° and -50° latitude. We found a decreasing trend from about -35° latitude southwards. The average concentrations of As was 20 nM and of Sb 1.2 nM. Arsenic showed a more significant north to south trend than Sb. Arsenic concentration was highest at -23 ° latitude (21 nM) and the lowest at -43 ° latitude (17.7 nM). Antimony concentration was highest at -31 ° latitude (1.5 nM) and lowest at -35 ° latitude (1.0 nM). Our preliminary data suggests that the major industrial centres in Brazil (i.e., Sao Paolo, Rio de Janeiro) and Argentina (i.e., Buenos Aires) affect atmospheric metal fluxes to remote

  20. Estimation of radionuclide concentration of 238U, 226Ra, 232Th in air in Wuhan city

    International Nuclear Information System (INIS)

    Shi Jinhua; Chen Changhua

    1989-01-01

    The concentrations of 238 U, 226 Ra and 232 Th in air in Wuhan area were estimated by assuming that they originate from resuspended particles of soil and investigating the dust content in air and the concentrations of these radionuclides in soil. 60 soil samples were collected from April to October, 1984, and 7346 air dust samples during 1981-1985. The estimated mean air concentrations of 238 U, 226 Ra and 232 Th were 24.0 x 10 -9 , 18.9 x 10 -9 and 28.7 x 10 -9 , Bq/L, respectively. Their highest values were observed of 30.4 x 10 -9 , 23.9 x 10 -9 and 36.2 x 10 -9 Bq/L in 1983. Seasonal change of the concentrations was clear as shown in the data of 1984 and 1985, which was related to the meterological conditions. Among the 6 districts of Wuhan city, the highest concentration was in Qingshan and the lowest in Wuchang

  1. Riparian zone controls on base cation concentrations in boreal streams

    Science.gov (United States)

    Ledesma, J. L. J.; Grabs, T.; Futter, M. N.; Bishop, K. H.; Laudon, H.; Köhler, S. J.

    2013-01-01

    Forest riparian zones are a major in control of surface water quality. Base cation (BC) concentrations, fluxes, and cycling in the riparian zone merit attention because of increasing concern of negative consequences for re-acidification of surface waters from future climate and forest harvesting scenarios. We present a two-year study of BC and silica (Si) flow-weighted concentrations from 13 riparian zones and 14 streams in a boreal catchment in northern Sweden. The Riparian Flow-Concentration Integration Model (RIM) was used to estimate riparian zone flow-weighted concentrations and tested to predict the stream flow-weighted concentrations. Spatial variation in BC and Si concentrations as well as in flow-weighted concentrations was related to differences in Quaternary deposits, with the largest contribution from lower lying silty sediments and the lowest contribution from wetland areas higher up in the catchment. Temporal stability in the concentrations of most elements, a remarkably stable Mg / Ca ratio in the soil water and a homogeneous mineralogy suggest that the stable patterns found in the riparian zones are a result of distinct mineralogical upslope groundwater signals integrating the chemical signals of biological and chemical weathering. Stream water Mg / Ca ratio indicates that the signal is subsequently maintained in the streams. RIM gave good predictions of Ca, Mg, and Na flow-weighted concentrations in headwater streams. The difficulty in modelling K and Si suggests a stronger biogeochemical influence on these elements. The observed chemical dilution effect with flow in the streams was related to variation in groundwater levels and element concentration profiles in the riparian zones. This study provides a first step toward specific investigations of the vulnerability of riparian zones to changes induced by forest management or climate change, with focus on BC or other compounds.

  2. Cytotoxicity of β-D-glucose/sucrose-coated silver nanoparticles depends on cell type, nanoparticles concentration and time of incubation

    Science.gov (United States)

    Vergallo, Cristian; Panzarini, Elisa; Carata, Elisabetta; Ahmadi, Meysam; Mariano, Stefania; Tenuzzo, Bernardetta Anna; Dini, Luciana

    2016-06-01

    The use of silver NanoParticles (AgNPs) in several consumer commercialized products, like food contact materials, medical devices and cosmetics has increased significantly, owing to their antibacterial and antifungal properties. Even though the NPs are widely diffused, due to the great variety in size, coating or shape, controversial data on their possible detrimental health effects still exist. Herein, by performing an easy and fast green method synthesis, we used β-D-glucose/sucrose to stabilize AgNPs and avoid the release of cytotoxic soluble silver ions Ag+ in the culture medium. The cytotoxic effects of these β-D-Glucose/Sucrose-Coated AgNPs (AgNPs-GS) was assessed on two cell culture models, which are human liver HepG2 and human Peripheral Blood Lymphocytes (PBLs) cells. AgNPs-GS, as determined by Transmission Electron Microscopy (TEM) analyses, had an average diameter of 30±5 nm, a spherical shape and were well-dispersed in the freshly-prepared solution. In addition, they were found spectrophotometrically stable throughout the experiment. Cytotoxicity, determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) reduction assay, was evaluated by using two AgNPs-GS amounts, indicated as highest (10×103 of NPs/cell) and lowest (2×103 NPs/cell) concentration for 6, 12 and 24 h. The highest concentration of AgNPs-GS was significantly cytotoxic for both HepG2 and PBLs cells at all times, when compared with the negative control; conversely, the lowest amount of AgNPs-GS was toxic only for HepG2 cells. A significant increase of Reactive Oxygen Species (ROS) levels, determined by Nitro Blue Tetrazolium (NBT) reduction assay, was observed only in PBLs after treatment with NPs, by reaching maximum levels after the incubation with the lowest amount of NPs for 24 h. Significant morphological changes, depending on NPs/cell amount, characteristic of cell toxicity, like shape, cytoplasm, and nucleus alterations, were observed in lymphocytes and Hep

  3. Comparison of DNA extraction protocols to detect Mycobacterium bovis in bovine tissue by PCR

    Directory of Open Access Journals (Sweden)

    Cássia Yumi Ikuta

    2016-11-01

    Full Text Available The current scenario of international beef trading has increased the pressure for better and faster diagnosis of bovine tuberculosis. Although traditional culture remains the gold standard method to confirm Mycobacterium bovis infection, it is exceedingly time consuming, and demands viable mycobacteria. Molecular methods overcome the flaws of the bacteriological methods with faster detection and identification. However, mycobacterial features like a complex cell wall and pathogen–host interaction make the molecular detection a challenge. Three protocols for DNA extraction (A, B and C from bovine tissues were tested to verify the most suitable technique for routine diagnostic assessment of their specificity and sensitivity. Thirty culture-positive and thirty culture-negative granulomatous lesions were included in the trial. From each sample, three tissue suspensions at different dilutions (10-1, 10-2 and 10-3 were prepared and submitted to DNA extraction. PCR procedures targeting IS6110 were performed, employing two volumes of DNA: 5 µL of all three dilutions, and 2.5 µL of the 10-1 dilution. Protocol A was able to detect members of the M. tuberculosis complex in most samples. The sensitivity of the test decreased with increase in tissue-suspension dilution. Although Protocol A presented the highest sensitivity followed by C and B, it showed the lowest specificity, which can be due to a failure in primary isolation caused by the lack of viable organisms or incubation time. Regardless classical bacteriological methods are still recommended by OIE, after evaluating the sensitivity of DNA extraction protocols and PCR procedures, we conclude that the best strategy for M. bovis detection is to follow Protocol A on concentrated tissue suspensions.

  4. Diurnal and seasonal variations of concentration and size distribution of nano aerosols (10-1100 nm) enclosing radon decay products in the Postojna Cave, Slovenia.

    Science.gov (United States)

    Bezek, M; Gregoric, A; Kávási, N; Vaupotic, J

    2012-11-01

    At the lowest point along the tourist route in the Postojna Cave, the activity concentration of radon ((222)Rn) short-lived decay products and number concentration and size distribution of background aerosol particles in the size range of 10-1100 nm were measured. In the warm yearly season, aerosol concentration was low (52 cm(-3)) with 21 % particles smaller than 50 nm, while in the cold season, it was higher (1238 cm(-3)) with 8 % of <50 nm particles. Radon activity concentrations were 4489 and 1108 Bq m(-3), and fractions of unattached radon decay products were 0.62 and 0.13, respectively.

  5. Effect of different concentrations of dl-isoleucine, dl-valine, and dl-alanine on growth and sporulation in Fusarium oxysporum f. udum (Butl.) Sn. et H.

    Science.gov (United States)

    Prasad, M; Chaudhary, S K

    1977-01-01

    D1-alanine and dl-valine, when added as an extra nitrogen for fortifying the already present inorganic nitrogen source, actually acted as growth retardant for F. oxysporum f. udum (Butl.) Sn. et H. Sporulation of microconidia was indifferently affected by these two amino acids. DI-valine stimulated microconidial formation in young cultures only. In both young and old cultures the lowest concentration of dl-valine depressed macronidial sporulation. In old cultures the lowest concentration of valine stimulated chlamydospore differentiation rapidly, higher concentrations being less effective. D1-alanine, as an additional nitrogen source, depressed both macro- and microconidal sporulation. It did not even invigorate chlamydospore formation. D1-isoleucine, on the other hand, belongs to the category of growth promoters and profuse and stimulative sporulators of macro- and microconidia. This pathogen needs very specific and preferential doses of the three amino acids, if these are used as a booster in addition to the already present nitrogen source. The response, both in terms of mycelial growth and sporulation of the three spore forms, was also conditioned by the age of the culture.

  6. Maternal Methadone Dose, Placental Methadone Concentrations, and Neonatal Outcomes

    Science.gov (United States)

    de Castro, Ana; Jones, Hendreé E.; Johnson, Rolley E.; Gray, Teresa R.; Shakleya, Diaa M.; Huestis, Marilyn A.

    2015-01-01

    BACKGROUND Few investigations have used placenta as an alternative matrix to detect in utero drug exposure, despite its availability at the time of birth and the large amount of sample. Methadone-maintained opioid-dependent pregnant women provide a unique opportunity to examine the placental disposition of methadone and metabolite [2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP)], to explore their correlations with maternal methadone dose and neonatal outcomes, and to test the ability to detect in utero exposure to illicit drugs. METHODS We calculated the correlations of placental methadone and EDDP concentrations and their correlations with maternal methadone doses and neonatal outcomes. Cocaine- and opiate-positive placenta results were compared with the results for meconium samples and for urine samples collected throughout gestation. RESULTS Positive correlations were found between placental methadone and EDDP concentrations (r = 0.685), and between methadone concentration and methadone dose at delivery (r = 0.542), mean daily dose (r = 0.554), mean third-trimester dose (r = 0.591), and cumulative daily dose (r = 0.639). The EDDP/methadone concentration ratio was negatively correlated with cumulative daily dose (r = 0.541) and positively correlated with peak neonatal abstinence syndrome (NAS) score (r = 0.513). Placental EDDP concentration was negatively correlated with newborn head circumference (r = 0.579). Cocaine and opiate use was detected in far fewer placenta samples than in thrice-weekly urine and meconium samples, a result suggesting a short detection window for placenta. CONCLUSIONS Quantitative methadone and EDDP measurement may predict NAS severity. The placenta reflects in utero drug exposure for a shorter time than meconium but may be useful when meconium is unavailable or if documentation of recent exposure is needed. PMID:21245372

  7. Failures of TDDFT in describing the lowest intramolecular charge-transfer excitation in para-nitroanilin

    DEFF Research Database (Denmark)

    Eriksen, J.J.; Sauer, S.P.A.; Mikkelsen, K.V.

    2013-01-01

    We investigate the failure of Time{Dependent Density Functional Theory (TDDFT) with the CAM{B3LYP exchange{correlation (xc) functional coupled to the Polarizable Embedding (PE) scheme (PE-CAM-B3LYP) in reproducing the solvatochromic shift of the lowest intense charge{transfer excitation in para...... the electric dipole moments in the gas phase and for 100 solvent congurations. We find that CAM-B3LYP overestimates the amount of charge separation inherent in the ground state and TDDFT/CAM-B3LYP drastically underestimates this amount in the excited charge-transfer state. As the errors in the solvatochromatic...... to benchmark results of TDDFT calculations with CAM-B3LYP for intramolecular charge{transfer excitations in molecular systems similar to pNA against higher{level ab initio wave function methods, like, e.g., CCSD, prior to their use. Using the calculated change in dipole moment upon excitation as a measure...

  8. Favorable performance of the DFT methods in predicting the minimum-energy structure of the lowest triplet state of WF4

    International Nuclear Information System (INIS)

    Gutowski, M.; Univ. of Utah, Salt Lake City, UT

    1999-01-01

    The tetrahedral structure of the lowest triplet state of the WF 4 complex was examined using different variants of the density functional theory (DFT) and conventional ab initio methods. The low-level, conventional, ab initio methods, such as SCF, MP2, MP3, and CISD, predict the tetrahedral structure to be a minimum, whereas the DFT schemes predict an imaginary frequency for the e vibrational mode. Only after recovering electron correlation effects at the MP4 and higher levels, the conventional electronic structure methods also predict the T d structure to be a second-order stationary point. This is not the correlation but the exchange part of the DFT functionals which is responsible for the discrepancy between the DFT and low-level, conventional, ab initio predictions. The lowering of symmetry to C 2v leads to a minimum on the lowest triplet potential energy surface and the electronic energy difference between the T d and C 2v stationary points amounts to 0.85 and 0.96 kcal/mol at the B3LYP and CCSD(T) levels, respectively

  9. Microfluidic bead-based multienzyme-nanoparticle amplification for detection of circulating tumor cells in the blood using quantum dots labels

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, He, E-mail: mzhang_he@126.com; Fu, Xin; Hu, Jiayi; Zhu, Zhenjun

    2013-05-24

    -channel delivers fresh analyte solution to the reaction site which maintains a high concentration gradient differential to enhance mass transport. Based on the dual signal amplification strategy, the developed microfluidic bead-based nucleic acid sensor could discriminate as low as 5 fM (signal-to-noise (S/N) 3) of synthesized carcinoembryonic antigen (CEA) gene fragments and showed a 1000-fold increase in detection limit compared to the off-chip test. In addition, using spiked colorectal cancer cell lines (HT29) in the blood as a model system, the detection limit of this chip-based approach was found to be as low as 1 HT29 in 1 mL blood sample. This microfluidic bead-based nucleic acid sensor is a promising platform for disease-related nucleic acid molecules at the lowest level at their earliest incidence.

  10. Comparative study of the mutant prevention concentrations of moxifloxacin, levofloxacin, and gemifloxacin against pneumococci.

    Science.gov (United States)

    Credito, Kim; Kosowska-Shick, Klaudia; McGhee, Pamela; Pankuch, Glenn A; Appelbaum, Peter C

    2010-02-01

    We tested the propensity of three quinolones to select for resistant Streptococcus pneumoniae mutants by determining the mutant prevention concentration (MPC) against 100 clinical strains, some of which harbored mutations in type II topoisomerases. Compared with levofloxacin and gemifloxacin, moxifloxacin had the lowest number of strains with MPCs above the susceptibility breakpoint (P<0.001), thus representing a lower selective pressure for proliferation of resistant mutants. Only moxifloxacin gave a 50% MPC (MPC50) value (1 microg/ml) within the susceptible range.

  11. Evaluation of an alternative extraction procedure for enterotoxin determination in dairy products.

    Science.gov (United States)

    Meyrand, A; Atrache, V; Bavai, C; Montet, M P; Vernozy-Rozand, C

    1999-06-01

    A concentration protocol based on trichloroacetic acid precipitation was evaluated and compared with the reference method using dialysis concentration. Different quantities of purified staphylococcal enterotoxins were added to pasteurized Camembert-type cheeses. Detection of enterotoxins in these cheeses was performed using an automated detection system. Raw goat milk Camembert-type cheeses involved in a staphylococcal food poisoning were also tested. Both enterotoxin extraction methods allowed detection of the lowest enterotoxin concentration level used in this study (0.5 ng g-1). Compared with the dialysis concentration method, TCA precipitation of staphylococcal enterotoxins was 'user-friendly' and less time-consuming. These results suggest that TCA precipitation is a rapid (1 h), simple and reliable method of extracting enterotoxin from food which gives excellent recovery from dairy products.

  12. Detection Efficiency of a ToF Spectrometer from Heavy-Ion Elastic Recoil Detection

    International Nuclear Information System (INIS)

    Barbara, E. de; Marti, G. V.; Capurro, O. A.; Fimiani, L.; Mingolla, M. G.; Negri, A. E.; Arazi, A.; Figueira, J. M.; Pacheco, A. J.; Martinez Heimann, D.; Carnelli, P. F. F.; Fernandez Niello, J. O.

    2010-01-01

    The detection efficiency of a time-of-flight system based on two micro-channel plates (MCP) time zero detectors plus a conventional silicon surface barrier detector was obtained from heavy ion elastic recoil measurements (this ToF spectrometer is mainly devoted to measurements of total fusion cross section of weakly bound projectiles on different mass-targets systems). In this work we have used beams of 7 Li, 16 O, 32 S and 35 Cl to study the mass region of interest for its application to measurements fusion cross sections in the 6,7 Li+ 27 Al systems at energies around and above the Coulomb barrier (0.8V B ≤E≤2.0V B ). As the efficiency of a ToF spectrometer is strongly dependent on the energy and mass of the detected particles, we have covered a wide range of the scattered particle energies with a high degree of accuracy at the lowest energies. The different experimental efficiency curves obtained in that way were compared with theoretical electronic stopping power curves on carbon foils and were applied.

  13. Electrochemical aptasensor for detecting tetracycline in milk

    International Nuclear Information System (INIS)

    Le, Thi Hanh; Pham, Van Phuc; La, Thi Huyen; Le, Quang Huan; Phan, Thi Binh

    2016-01-01

    A rapid, simple and sensitive biosensor system for tetracycline detection is very important in food safety. In this paper we developed a label-free aptasensor for electrochemical detection of tetracycline. According to the electrochemical impendence spectroscopy (EIS) analysis, there was a linear relationship between the concentration of tetracycline and the electron transfer resistance from 10 to 3000 ng ml −1 of the tetracycline concentration. The detection limit was 10 ng ml −1 in 15 min detection duration. The prepared aptasensor showed a good reproducibility with an acceptable stability in tetracycline detection. The recoveries of tetracycline in spiked milk samples were in the range of 88.1%–94.2%. The aptasensor has sensitivity 98% and specificity of 100%. (paper)

  14. Serum concentrations of cholesterol, apolipoprotein A-I and apolipoprotein B in a total of 1694 meat-eaters, fish-eaters, vegetarians and vegans.

    Science.gov (United States)

    Bradbury, K E; Crowe, F L; Appleby, P N; Schmidt, J A; Travis, R C; Key, T J

    2014-02-01

    The objective of this study was to describe serum lipid concentrations, including apolipoproteins A-I and B, in different diet groups. A cross-sectional analysis of a sample of 424 meat-eaters, 425 fish-eaters, 423 vegetarians and 422 vegans, matched on sex and age, from the European Prospective Investigation into Cancer and Nutrition-Oxford cohort. Serum concentrations of total, and high-density lipoprotein (HDL) cholesterol, as well as apolipoproteins A-I and B were measured, and serum non-HDL cholesterol was calculated. Vegans had the lowest body mass index (BMI) and the highest and lowest intakes of polyunsaturated and saturated fat, respectively. After adjustment for age, alcohol and physical activity, compared with meat-eaters, fish-eaters and vegetarians, serum concentrations of total and non-HDL cholesterol and apolipoprotein B were significantly lower in vegans. Serum apolipoprotein A-I concentrations did not differ between the diet groups. In males, the mean serum total cholesterol concentration was 0.87 mmol/l lower in vegans than in meat-eaters; after further adjustment for BMI this difference was 0.76 mmol/l. In females, the difference in total cholesterol between these two groups was 0.6 mmol/l, and after further adjustment for BMI was 0.55 mmol/l. [corrected]. In this study, which included a large number of vegans, serum total cholesterol and apolipoprotein B concentrations were lower in vegans compared with meat-eaters, fish-eaters and vegetarians. A small proportion of the observed differences in serum lipid concentrations was explained by differences in BMI, but a large proportion is most likely due to diet.

  15. Seasonal variation of copper and zinc concentrations in the oyster Saccostrea cuccullata from the Dampier Archipelago, Western Australia: implications for pollution monitoring.

    Science.gov (United States)

    Talbot, V

    1986-12-01

    The intertidal rock oyster Saccostrea cuccullata, sampled at eight sites on eight occasions over a 1-year period, contained mean Cu and Zn concentrations ranging between 34 and 267 and 206 and 4078 mg kg-1 dry weight, respectively. In the study area, Cu and Zn emanate from sewage and boat slips (antifouling paints), while Zn probably also originates from coolant water from an electricity power generating station and iron ore exporting facilities. Highest oyster wet weight, Cu and Zn concentrations and loads occurred in January (spawning period), indicating that metal variation was not reciprocating wet weight. Lowest metal concentrations and loads occurred in October (period of onset of gametogenesis), while lowest wet weight occurred in April (post-spawning period). No significant (P less than 0.001) variation in the wet to dry weight ratio was noted temporally. However, significant, though slight, variation was noted between polluted and unpolluted oysters. Results of this study indicate that pollution control monitoring programs should consider: seasonal variation of metal concentrations; portion of the year during which standards are exceeded; oyster size and availability for human consumption; suitability of standards where shellfish are not consumed as a staple diet; appropriate size indicies which can be used for selecting specimens for intersite comparisons; wet to dry weight calculations: techniques, spatial and temporal variations; and the physical dynamics of sites used.

  16. Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

    Science.gov (United States)

    Kurzeja, R. J.; Buckley, R. L.; Werth, D. W.; Chiswell, S. R.

    2018-03-01

    A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

  17. Diurnal and seasonal variations of concentration and size distribution of nano aerosols (10-1100 nm) enclosing radon decay products in the Postojna Cave, Slovenia

    International Nuclear Information System (INIS)

    Bezek, M.; Gregoric, A.; Kavasi, N.; Vaupotic, J.

    2012-01-01

    At the lowest point along the tourist route in the Postojna Cave, the activity concentration of radon ( 222 Rn) short-lived decay products and number concentration and size distribution of background aerosol particles in the size range of 10-1100 nm were measured. In the warm yearly season, aerosol concentration was low (52 cm -3 ) with 21 % particles smaller than 50 nm, while in the cold season, it was higher (1238 cm -3 ) with 8 % of -3 , and fractions of unattached radon decay products were 0.62 and 0.13, respectively. (authors)

  18. Reduction of serum triacylglycerol-rich lipoprotein concentrations in cows with hepatic lipidosis.

    Science.gov (United States)

    Herdt, T H; Liesman, J S; Gerloff, B J; Emery, R S

    1983-02-01

    The hepatic and serum lipid concentrations in 49 dairy cows with displaced abomasum, 7 postpartum cows fasted for 6 days, and 14 healthy postpartum cows were studied. The cows with displaced abomasums were retrospectively allotted to 2 groups: those with greater than 15% liver fat (DAHF) and those with less than 15% liver fat (DALF). Liver total lipid concentrations were high in the DAHF group, exceeding these values in the fasted cows by 30% and in the healthy and DALF cows by 63% on the average. In contrast, the liver phospholipid concentrations were low in the DAHF group, intermediate in the fasted and DALF groups and high in the healthy group. On a group basis, an inverse relationship was observed between serum and liver lipid concentrations. The serum concentrations of both total and dextran-sulfate-precipitable (DSP) lipids were high in the fasted cows and were less in the DALF and healthy cows and in the DAHF cows (lowest). The between-group differences in serum total and serum DSP concentrations of triacylglycerol, cholesterol, and phospholipid followed the same quantitative pattern as the total lipids. However, the relative difference between groups was greater for each of the DSP lipid fractions. These results support the hypothesis that severe hepatic lipidosis in cattle occurs due to impaired hepatic lipoprotein synthesis and secretion.

  19. Study of the specific concentrations of 40K, 224Ra, 226Ra and 228Ra in some seasonings marketed in Rio de Janeiro City

    International Nuclear Information System (INIS)

    Garcêz, Ricardo W.D.; Lopes, José M.; Silva, Leandro B.; Silva, Ademir X. da; Lima, Marco A.F.

    2017-01-01

    The seasoning are vegetables substances used in foods to enhance their flavor, aroma and color. This work presents an investigation of the activity concentration of Naturally Occurring Radioactive Materials (NORMs) in 28 samples of seasoning utilized by brazilian population. The seasoning samples were measured using gamma spectroscopy technique with a high-purity germanium (HPGe) detector, a non-destructive nuclear method and with the LabSOCS software for the calculation of the efficiency curve. The analysis shows that the activity concentration of 40 K was measured in all samples and ranges from 21.0 Bq/kg to 1288 Bq/kg. The highest concentration activity of 40 K was measured to 'cheiro verde', a local seasoning made of chives (Allium Schoenoprasum) and parsley (Petroselinum Crispum), while annatto, made with the fruit of Bixa Orelhana, had the lowest activity concentration. Brazil nut (Bertholletia Excelsa) presented the highest concentrations for 226 Ra and 228 Ra with 24 Bq/kg and 25.7 Bq/kg, respectively and black pepper (Piper Nigrum) presented the highest concentration for 224 Ra with 33.9 Bq/kg. The highest effective dose for members of the public due to ingestion was 23.5 μSv/y due to Brazil nut and the lowest effective dose was found for annatto: 0.13 μSv/y. The syrian seasoning sample present specific concentration of 6.1±1.1 Bq/kg for 137 Cs and 0.08 μSv/y of effective dose. The values found in this work do not represent a risk to human health. (author)

  20. Analysis of ultra-high sensitivity configuration in chip-integrated photonic crystal microcavity bio-sensors

    International Nuclear Information System (INIS)

    Chakravarty, Swapnajit; Hosseini, Amir; Xu, Xiaochuan; Zhu, Liang; Zou, Yi; Chen, Ray T.

    2014-01-01

    We analyze the contributions of quality factor, fill fraction, and group index of chip-integrated resonance microcavity devices, to the detection limit for bulk chemical sensing and the minimum detectable biomolecule concentration in biosensing. We analyze the contributions from analyte absorbance, as well as from temperature and spectral noise. Slow light in two-dimensional photonic crystals provide opportunities for significant reduction of the detection limit below 1 × 10 −7 RIU (refractive index unit) which can enable highly sensitive sensors in diverse application areas. We demonstrate experimentally detected concentration of 1 fM (67 fg/ml) for the binding between biotin and avidin, the lowest reported till date

  1. NEW X-RAY DETECTIONS OF WNL STARS

    International Nuclear Information System (INIS)

    Skinner, Stephen L.; Zhekov, Svetozar A.; Güdel, Manuel; Schmutz, Werner; Sokal, Kimberly R.

    2012-01-01

    Previous studies have demonstrated that putatively single nitrogen-type Wolf-Rayet stars (WN stars) without known companions are X-ray sources. However, almost all WN star X-ray detections so far have been of earlier WN2-WN6 spectral subtypes. Later WN7-WN9 subtypes (also known as WNL stars) have proved more difficult to detect, an important exception being WR 79a (WN9ha). We present here new X-ray detections of the WNL stars WR 16 (WN8h) and WR 78 (WN7h). These new results, when combined with previous detections, demonstrate that X-ray emission is present in WN stars across the full range of spectral types, including later WNL stars. The two WN8 stars observed to date (WR 16 and WR 40) show unusually low X-ray luminosities (L x ) compared to other WN stars, and it is noteworthy that they also have the lowest terminal wind speeds (v ∞ ). Existing X-ray detections of about a dozen WN stars reveal a trend of increasing L x with wind luminosity L wind = (1/2)M-dot v 2 ∞ , suggesting that wind kinetic energy may play a key role in establishing X-ray luminosity levels in WN stars.

  2. NEW X-RAY DETECTIONS OF WNL STARS

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, Stephen L. [Center for Astrophysics and Space Astronomy (CASA), University of Colorado, Boulder, CO 80309-0389 (United States); Zhekov, Svetozar A. [Space and Solar-Terrestrial Research Institute, Moskovska str. 6, Sofia-1000 (Bulgaria); Guedel, Manuel [Department of Astronomy, University of Vienna, Tuerkenschanzstr. 17, A-1180 Vienna (Austria); Schmutz, Werner [Physikalisch-Meteorologisches Observatorium Davos (PMOD), Dorfstrasse 33, CH-7260 Davos Dorf (Switzerland); Sokal, Kimberly R., E-mail: Stephen.Skinner@colorado.edu [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904-4325 (United States)

    2012-05-15

    Previous studies have demonstrated that putatively single nitrogen-type Wolf-Rayet stars (WN stars) without known companions are X-ray sources. However, almost all WN star X-ray detections so far have been of earlier WN2-WN6 spectral subtypes. Later WN7-WN9 subtypes (also known as WNL stars) have proved more difficult to detect, an important exception being WR 79a (WN9ha). We present here new X-ray detections of the WNL stars WR 16 (WN8h) and WR 78 (WN7h). These new results, when combined with previous detections, demonstrate that X-ray emission is present in WN stars across the full range of spectral types, including later WNL stars. The two WN8 stars observed to date (WR 16 and WR 40) show unusually low X-ray luminosities (L{sub x} ) compared to other WN stars, and it is noteworthy that they also have the lowest terminal wind speeds (v{sub {infinity}}). Existing X-ray detections of about a dozen WN stars reveal a trend of increasing L{sub x} with wind luminosity L{sub wind} = (1/2)M-dot v{sup 2}{sub {infinity}}, suggesting that wind kinetic energy may play a key role in establishing X-ray luminosity levels in WN stars.

  3. Maternal Buprenorphine Dose, Placenta Buprenorphine and Metabolite Concentrations and Neonatal Outcomes

    Science.gov (United States)

    Concheiro, Marta; Jones, Hendreé E.; Johnson, Rolley E.; Choo, Robin; Shakleya, Diaa M.; Huestis, Marilyn A.

    2010-01-01

    Buprenorphine is approved as pharmacotherapy for opioid dependence in non-pregnant patients in multiple countries, and is currently under investigation for pregnant women in the US and Europe. This research evaluates the disposition of buprenorphine, opiates, cocaine, and metabolites in 5 term placentas from a US cohort. Placenta and matched meconium concentrations were compared, and relationships between maternal buprenorphine dose, placenta concentrations, and neonatal outcomes following controlled administration during gestation were investigated. Buprenorphine and/or metabolites were detected in all placenta specimens and were uniformly distributed across this tissue (CV<27.5%, 4 locations), except for buprenorphine in 3 placentas. In 2 of these, buprenorphine was not detected in some locations and, in the 3rd placenta, was totally absent. Median (range) concentrations were buprenorphine 1.6ng/g (not detected to 3.2), norbuprenorphine 14.9ng/g (6.2 to 24.2), buprenorphine-glucuronide 3ng/g (1.3 to 5.0) and norbuprenorphine-glucuronide 14.7ng/g (11.4 to 25.8). Placenta is a potential alternative matrix for detecting in utero buprenorphine exposure, but at lower concentrations (15–70 fold) than in meconium. Statistically significant correlations were observed for mean maternal daily dose from enrollment to delivery and placenta buprenorphine-glucuronide concentration, and for norbuprenorphine-glucuronide concentrations and time to neonatal abstinence syndrome (NAS) onset and duration, and for norbuprenorphine/norbuprenorphine-glucuronide ratio and maximum NAS score, and newborn length. Analysis of buprenorphine and metabolites in this alternative matrix, an abundant waste product available at the time of delivery, may be valuable for prediction of neonatal outcomes for clinicians treating newborns of buprenorphine-exposed women. PMID:20216119

  4. Solute concentration affects bradykinin-mediated increases in renal prostaglandin E2

    International Nuclear Information System (INIS)

    Zenser, T.V.; Davis, E.S.; Rapp, N.S.; Davis, B.B.

    1981-01-01

    The effects of solute concentration on the bradykinin-mediated increase in inner medullary slice prostaglandin E2 (PGE2) synthesis were investigated. PG content was determined by specific RIA. Bradykinin stimulation was prevented by the addition of the following solutes to Krebs buffer: 1.0 M urea, 0.5 or 1.0 M NaCl, 0.5 or 1.0 M mannitol, 1.0 M urea plus 0.5 M NaCl, or 1.0 M mannitol plus 0.5 M NaCl. By contrast, basal PGE2 synthesis was increased by 1.0 M mannitol or by 1.0 M mannitol plus 0.5 M NaCl, but decreased by 1.0 M urea. Urea elicited a concentration-dependent, reversible inhibition of bradykinin stimulation, with 0.01 M urea being the lowest effective concentration. By contrast, basal PGE2 synthesis was only reduced at a urea concentration greater than 0.6 M. Arachidonic acid-mediated increases in both PGE2 and PGF2 alpha synthesis were not prevented by 1.0 M urea. The latter suggests that neither PG endoperoxide synthetase nor PG endoperoxide E isomerase are inhibited by urea. The data indicate that different hypertonic solutions have different effects on basal PG production, but all inhibit bradykinin stimulation

  5. Sensor and instrumentation for progesterone detection

    KAUST Repository

    Zia, Asif I.

    2012-05-01

    The reported research work uses a real time and noninvasive method to detect progesterone hormone concentration in purified water using Electrochemical Impedance Spectroscopy (E.I.S.) technique. Planar capacitive sensor, consisting of inter-digitated microelectrodes, is designed and fabricated on silicon substrate using thin-film Microelectromechanical system (MEMS) based semiconductor device fabrication technology. The sensor in conjunction with EIS is used to evaluate conductivity, permeability and dielectric properties of reproductive hormone progesterone and its concentration quantification in purified water. Impedance spectrums are obtained with various concentrations of the hormone in purified water by using an electric circuit in order to extract sample conductance. Relationship of sample conductance with progesterone concentration level is studied in this research work. The ability of E.I.S. to detect progesterone concentration is aimed to be used in dairy farming industry in order to obtain better reproductive performance of the dairy cattle. © 2012 IEEE.

  6. Sensor and instrumentation for progesterone detection

    KAUST Repository

    Zia, Asif I.; Mohd. Syaifudin, A. R.; Mukhopadhyay, Subhas Chandra; Yu, Paklam; Al-Bahadly, Ibrahim H.; Kosel, Jü rgen; Gooneratne, Chinthaka Pasan

    2012-01-01

    The reported research work uses a real time and noninvasive method to detect progesterone hormone concentration in purified water using Electrochemical Impedance Spectroscopy (E.I.S.) technique. Planar capacitive sensor, consisting of inter-digitated microelectrodes, is designed and fabricated on silicon substrate using thin-film Microelectromechanical system (MEMS) based semiconductor device fabrication technology. The sensor in conjunction with EIS is used to evaluate conductivity, permeability and dielectric properties of reproductive hormone progesterone and its concentration quantification in purified water. Impedance spectrums are obtained with various concentrations of the hormone in purified water by using an electric circuit in order to extract sample conductance. Relationship of sample conductance with progesterone concentration level is studied in this research work. The ability of E.I.S. to detect progesterone concentration is aimed to be used in dairy farming industry in order to obtain better reproductive performance of the dairy cattle. © 2012 IEEE.

  7. Perchlorate Detection at Nanomolar Concentrations by Surface-Enhanced Raman Scattering

    Science.gov (United States)

    2009-01-01

    grooves/mm grating light path controlled by Renishaw WiRE software and analyzed by Galactic GRAMS software. RESULTS AND DISCUSSION Quantitative... Federal Rights License 14. ABSTRACT Perchlorate (ClO4 ) has emerged as a widespread environmental contaminant and has been detected in various food...by means of dynamic light scattering using a ZetaPlus particle size analyzer (Brookhaven Instruments, Holtsville, NY). Data were collected for every

  8. Season, molt, and body size influence mercury concentrations in grebes

    Science.gov (United States)

    Hartman, Christopher; Ackerman, Joshua T.; Herzog, Mark; Eagles-Smith, Collin A.

    2017-01-01

    We studied seasonal and physiological influences on mercury concentrations in western grebes (Aechmophorus occidentalis) and Clark's grebes (A. occidentalis) across 29 lakes and reservoirs in California, USA. Additionally, at three of these lakes, we conducted a time series study, in which we repeatedly sampled grebe blood mercury concentrations during the spring, summer, and early fall. Grebe blood mercury concentrations were higher among males (0.61 ± 0.12 μg/g ww) than females (0.52 ± 0.10 μg/g ww), higher among Clark's grebes (0.58 ± 0.12 μg/g ww) than western grebes (0.51 ± 0.10 μg/g ww), and exhibited a strong seasonal pattern (decreasing by 60% from spring to fall). Grebe blood THg concentrations exhibited a shallow, inverse U-shaped pattern with body size, and was lowest among the smallest and largest grebes. Further, the relationship between grebe blood mercury concentrations and wing primary feather molt exhibited a shallow U-shaped pattern, where mercury concentrations were highest among birds that had not yet begun molting, decreased approximately 24% between pre-molt and late molt, and increased approximately 19% from late molt to post-molt. Because grebes did not begin molting until mid-summer, lower grebe blood mercury concentrations observed in late summer and early fall were consistent with the onset of primary feather molt. However, because sampling date was a much stronger predictor of grebe mercury concentrations than molt, other seasonally changing environmental factors likely played a larger role than molt in the seasonal variation in grebe mercury concentrations. In the time series study, we found that seasonal trends in grebe mercury concentrations were not consistent among lakes, indicating that lake-specific variation in mercury dynamics influence the overall seasonal decline in grebe blood mercury concentrations. These results highlight the importance of accounting for sampling date, as well as ecological processes that may

  9. Effect of recall rate on earlier screen detection of breast cancers based on the Dutch performance indicators.

    NARCIS (Netherlands)

    Otten, J.D.M.; Karssemeijer, N.; Hendriks, J.H.C.L.; Groenewoud, J.H.; Fracheboud, J.; Verbeek, A.L.M.; Koning, H.J. de; Holland, R.

    2005-01-01

    BACKGROUND: The recall rate (i.e., the rate at which mammographically screened women are recalled for additional assessment) in the Dutch breast screening program (0.89% in 2000 for subsequent examinations) is the lowest worldwide, with possible consequences including higher rates of late-detected

  10. Optimization of ultrasonic tube testing with concentric transducers

    International Nuclear Information System (INIS)

    Dufayet, J.-P.; Gambin, Raymond.

    1978-01-01

    In order to test tubes by ultrasonics without rotation, concentric transducers can be used with conical mirrors to detect transverse defects and with helical shaped mirrors to detect longitudinal defects. Further optimization studies have been carried out in order to bring the system highly operational. The respective advantages brought by the rotating screen or by our especially designed sectorial transducers are discussed [fr

  11. Optical detection of polychlorinated biphenyls

    Science.gov (United States)

    Kuncova, Gabriela; Berkova, Daniela; Burkhard, Jiri; Demnerova, Katerina; Pazlarova, Jarmila; Triska, Jan; Vrchotova, Nadezda

    1999-12-01

    In this paper we describe the detection of polychlorinated biphenyls (PCBs) which is based on the measurement of changes of optical absorption at 400 nm of the medium in an aerobic bioreactor with immobilized cells Pseudomonas species 2. The rate of production, composition and the concentration of yellow intermediates are influenced by concentration and composition of PCB mixtures, concentration of cells and by the methods of immobilization. The method was applied in the detection of commercial mixture D103. It was found that the advantageous carriers were inorganic or organic-inorganic matrices, which sorbed PCBs and a cell outgrowth from their surface was low. In water contaminated with transformer oil and chlorinated hydrocarbons the detection limit is 10-2 gD103/kg. In transformer oil the upper limit for degradation of D103 by sodium dehalogenation (1.5 gD103 /kgoil) was determined also in the presence of the same concentration of trichloroethylene. The employment to of a liquid core waveguide spectrophotometer instead of a diode array spectrophotometer increased the sensitivity of the measurement of yellow intermediates by a factor of 100. An extrinsic fiber-optic sensor was used for in-situ measurement during biodegradation of PCBs in bioreactors.

  12. Comparison of Plasma, Saliva, and Hair Levetiracetam Concentrations.

    Science.gov (United States)

    Karaś-Ruszczyk, Katarzyna; Kuczyńska, Julita; Sienkiewicz-Jarosz, Halina; Kurkowska-Jastrzębska, Iwona; Bienkowski, Przemyslaw; Restel, Magdalena; Samochowiec, Jerzy; Mierzejewski, Pawel

    2017-06-01

    Previous findings revealed high correlations between serum/plasma and saliva levetiracetam concentrations, indicating saliva as an alternative matrix for monitoring levetiracetam therapy. Levetiracetam concentration in the hair, which could reflect long-term drug exposure and patients' compliance, has not been systematically tested, as yet. The aim of this study was to determine the correlation between plasma, saliva, and hair levetiracetam concentrations in 47 patients with epilepsy. Plasma, saliva, and hair levetiracetam concentrations were measured by liquid chromatography-tandem mass spectrometry with positive ionization. Levetiracetam saliva and plasma concentrations were highly correlated (r = 0.93). Plasma concentrations were not influenced by sex, age, and other concomitant antiepileptic drugs. Levetiracetam hair concentrations correlated with plasma concentrations (r = 0.36) but not daily dose (mg/kg). Drug hair concentrations were not influenced by hair color or treatment (dyed). The results tend to indicate that saliva may be a reliable alternative to plasma for monitoring levetiracetam concentrations. Levetiracetam can also be detected in human hair.

  13. Novel Fluorometric Method for the Determination of Production Rate and Steady-State Concentration of Photochemically Generated Superoxide Radical in Seawater Using 3',6'-(Diphenylphosphinyl)fluorescein.

    Science.gov (United States)

    Anifowose, Adebanjo Jacob; Takeda, Kazuhiko; Sakugawa, Hiroshi

    2015-12-15

    Superoxide radical (O2(•-)) is an important reactive oxygen species in seawater. Measurements of its production rates and steady-state concentrations generated by photochemical processes have been a Herculean task over the years. In this study, a probe - 3'6'-(diphenylphosphinyl)fluorescein (PF-1) - was used to trap photochemically generated O2(•-) in seawater, thereby yielding fluorescein. The fluorescein produced was measured by an isocratic fluorescence HPLC at excitation/emission wavelengths of 490/513 nm, respectively. The reaction rate constant of PF-1 with O2(•-) (kPF-1) was pH-dependent: (3.2-23.5) × 10(7) M(-1) s(-1) at pHTOT 7.65-8.50. By applying appropriate equations, both the production rate and the steady-state concentration of O2(•-) generated by photochemical reactions in the seawater were quantified. Under the optimized experimental conditions, fluorescein standards (3-50 nM) exhibited linearity in the seawater by HPLC. The photoformation of fluorescein, due to the reaction of PF-1 with the O2(•-) photochemically produced in the seawater, was linear within the 20 min irradiation. The detection limit of the fluorescein photoformation rate was 0.03 pM s(-1), defined as 3σ of the lowest standard fluorescein concentration per 20 min irradiation. Using this value, the yield of fluorescein, and the fraction of O2(•-) that reacted with PF-1 in the seawater, the detection limit of the O2(•-) photoformation rate was 1.78 pM s(-1). Superoxide measurements using the proposed method were relatively unaffected by the potential interfering species in seawater. Application of the proposed method to ten (10) seawater samples from the Seto Inland Sea, Japan, resulted in measured O2(•-) photoformation rates of 3.1-8.5 nM s(-1), with steady-state concentrations ranging (0.06-0.3) × 10(-10) M. The method is simple, requires no technical sample preparation, and can be used to analyze a large number of samples.

  14. Nanotip analysis for dielectrophoretic concentration of nanosized viral particles.

    Science.gov (United States)

    Yeo, Woon-Hong; Lee, Hyun-Boo; Kim, Jong-Hoon; Lee, Kyong-Hoon; Chung, Jae-Hyun

    2013-05-10

    Rapid and sensitive detection of low-abundance viral particles is strongly demanded in health care, environmental control, military defense, and homeland security. Current detection methods, however, lack either assay speed or sensitivity, mainly due to the nanosized viral particles. In this paper, we compare a dendritic, multi-terminal nanotip ('dendritic nanotip') with a single terminal nanotip ('single nanotip') for dielectrophoretic (DEP) concentration of viral particles. The numerical computation studies the concentration efficiency of viral particles ranging from 25 to 100 nm in radius for both nanotips. With DEP and Brownian motion considered, when the particle radius decreases by two times, the concentration time for both nanotips increases by 4-5 times. In the computational study, a dendritic nanotip shows about 1.5 times faster concentration than a single nanotip for the viral particles because the dendritic structure increases the DEP-effective area to overcome the Brownian motion. For the qualitative support of the numerical results, the comparison experiment of a dendritic nanotip and a single nanotip is conducted. Under 1 min of concentration time, a dendritic nanotip shows a higher sensitivity than a single nanotip. When the concentration time is 5 min, the sensitivity of a dendritic nanotip for T7 phage is 10(4) particles ml(-1). The dendritic nanotip-based concentrator has the potential for rapid identification of viral particles.

  15. Nanotip analysis for dielectrophoretic concentration of nanosized viral particles

    International Nuclear Information System (INIS)

    Yeo, Woon-Hong; Lee, Hyun-Boo; Kim, Jong-Hoon; Chung, Jae-Hyun; Lee, Kyong-Hoon

    2013-01-01

    Rapid and sensitive detection of low-abundance viral particles is strongly demanded in health care, environmental control, military defense, and homeland security. Current detection methods, however, lack either assay speed or sensitivity, mainly due to the nanosized viral particles. In this paper, we compare a dendritic, multi-terminal nanotip (‘dendritic nanotip’) with a single terminal nanotip (‘single nanotip’) for dielectrophoretic (DEP) concentration of viral particles. The numerical computation studies the concentration efficiency of viral particles ranging from 25 to 100 nm in radius for both nanotips. With DEP and Brownian motion considered, when the particle radius decreases by two times, the concentration time for both nanotips increases by 4–5 times. In the computational study, a dendritic nanotip shows about 1.5 times faster concentration than a single nanotip for the viral particles because the dendritic structure increases the DEP-effective area to overcome the Brownian motion. For the qualitative support of the numerical results, the comparison experiment of a dendritic nanotip and a single nanotip is conducted. Under 1 min of concentration time, a dendritic nanotip shows a higher sensitivity than a single nanotip. When the concentration time is 5 min, the sensitivity of a dendritic nanotip for T7 phage is 10 4 particles ml −1 . The dendritic nanotip-based concentrator has the potential for rapid identification of viral particles. (paper)

  16. Surprising abundance of Gallionella-related iron oxidizers in creek sediments at pH 4.4 or at high heavy metal concentrations

    Directory of Open Access Journals (Sweden)

    Maria eFabisch

    2013-12-01

    Full Text Available We identified and quantified abundant iron-oxidizing bacteria (FeOB at three iron-rich, metal-contaminated creek sites with increasing sediment pH from extremely acidic (R1, pH 2.7, to moderately acidic (R2, pH 4.4, to slightly acidic (R3, pH 6.3 in a former uranium-mining district. The geochemical parameters showed little variations over the 1.5 year study period. The highest metal concentrations found in creek sediments always coincided with the lowest metal concentrations in creek water at the slightly acidic site R3. Sequential extractions of R3 sediment revealed large portions of heavy metals (Ni, Cu, Zn, Pb, U bound to the iron oxide fraction. Light microscopy of glass slides exposed in creeks detected twisted stalks characteristic of microaerobic FeOB of the family Gallionellaceae at R3 but also at the acidic site R2. Sequences related to FeOB such as Gallionella ferruginea, Sideroxydans sp. CL21, Ferritrophicum radicicola, and Acidovorax sp. BrG1 were identified in the sediments. The highest fraction of clone sequences similar to the acidophilic ‘Ferrovum myxofaciens’ was detected in R1. Quantitative PCR using primer sets specific for Gallionella spp., Sideroxydans spp., and ‘Ferrovum myxofaciens’ revealed that approximately 72% (R2 sediment and 37% (R3 sediment of total bacterial 16S rRNA gene copies could be assigned to groups of FeOB with dominance of microaerobic Gallionella spp. at both sites. Gallionella spp. had similar and very high absolute and relative gene copy numbers in both sediment communities. Thus, Gallionella-like organisms appear to exhibit a greater acid and metal tolerance than shown before. Microaerobic FeOB from R3 creek sediment enriched in newly developed metal gradient tubes tolerated metal concentrations of 35 mM Co, 24 mM Ni, and 1.3 mM Cd, higher than those in sediments. Our results will extend the limited knowledge of FeOB at contaminated, moderately to slightly acidic environments.

  17. Surprising abundance of Gallionella-related iron oxidizers in creek sediments at pH 4.4 or at high heavy metal concentrations

    Science.gov (United States)

    Fabisch, Maria; Beulig, Felix; Akob, Denise M.; Küsel, Kirsten

    2013-01-01

    We identified and quantified abundant iron-oxidizing bacteria (FeOB) at three iron-rich, metal-contaminated creek sites with increasing sediment pH from extremely acidic (R1, pH 2.7), to moderately acidic (R2, pH 4.4), to slightly acidic (R3, pH 6.3) in a former uranium-mining district. The geochemical parameters showed little variations over the 1.5 year study period. The highest metal concentrations found in creek sediments always coincided with the lowest metal concentrations in creek water at the slightly acidic site R3. Sequential extractions of R3 sediment revealed large portions of heavy metals (Ni, Cu, Zn, Pb, U) bound to the iron oxide fraction. Light microscopy of glass slides exposed in creeks detected twisted stalks characteristic of microaerobic FeOB of the family Gallionellaceae at R3 but also at the acidic site R2. Sequences related to FeOB such as Gallionella ferruginea, Sideroxydans sp. CL21, Ferritrophicum radicicola, and Acidovorax sp. BrG1 were identified in the sediments. The highest fraction of clone sequences similar to the acidophilic “Ferrovum myxofaciens” was detected in R1. Quantitative PCR using primer sets specific for Gallionella spp., Sideroxydans spp., and “Ferrovum myxofaciens” revealed that ~72% (R2 sediment) and 37% (R3 sediment) of total bacterial 16S rRNA gene copies could be assigned to groups of FeOB with dominance of microaerobic Gallionella spp. at both sites. Gallionella spp. had similar and very high absolute and relative gene copy numbers in both sediment communities. Thus, Gallionella-like organisms appear to exhibit a greater acid and metal tolerance than shown before. Microaerobic FeOB from R3 creek sediment enriched in newly developed metal gradient tubes tolerated metal concentrations of 35 mM Co, 24 mM Ni, and 1.3 mM Cd, higher than those in sediments. Our results will extend the limited knowledge of FeOB at contaminated, moderately to slightly acidic environments.

  18. Research of the absorbance detection and fluorescence detection for multifunctional nutrition analyzer

    Science.gov (United States)

    Ni, Zhengyuan; Yan, Huimin; Ni, Xuxiang; Zhang, Xiuda

    2017-10-01

    The research of the multifunctional analyzer which integrates absorbance detection, fluorescence detection, time-resolved fluorescence detection, biochemical luminescence detection methods, can make efficient detection and analysis for a variety of human body nutrients. This article focuses on the absorbance detection and fluorescence detection system. The two systems are modular in design and controlled by embedded system, to achieve automatic measurement according to user settings. In the optical path design, the application of confocal design can improve the optical signal acquisition capability, and reduce the interference. A photon counter is used for detection, and a high performance counter module is designed to measure the output of photon counter. In the experiment, we use neutral density filters and potassium dichromate solution to test the absorbance detection system, and use fluorescein isothiocyanate FITC for fluorescence detection system performance test. The experimental results show that the absorbance detection system has a detection range of 0 4OD, and has good linearity in the detection range, while the fluorescence detection system has a high sensitivity of 1pmol/L concentration.

  19. LUSH-based SPR sensor for the detection of alcohols and pheromone

    Science.gov (United States)

    Lau, Hui-Chong; Lee, Yeon-Kyung; Kwon, Jae-Young; Sohn, Young-Soo; Lim, Jeong Ok

    2013-05-01

    Protein is a widely used sensing substrate in the biosensing technology. In the study conducted here, we used odorant binding protein, LUSH from Drosophila as a biosensing substrate in a miniaturized surface plasmon resonance (SPR) sensor. LUSH contains the specific alcohols binding sites, which mediates the detection of alcohols and pheromone. We first modified the surface of the gold sensor chip using the self assembled monolayer in the chloroform solution. The saturated concentration was determined prior to the detection of alcohols and pheromone at various concentrations. The results showed that the LUSH was saturated at 1000 μg/ml on the gold sensor chip. The detection response of LUSH was significant at higher concentration of alcohols. LUSH detected ethanol at concentration >=50% propanol was detected at >=25% whereas pheromone was detected at >=1.25 μg/μl. The results provide some fundamental information on the potential use of LUSH-based SPR as a simple and easy protein-based sensor in the near future.

  20. Serum concentrations of vitamin B12 and folate in British male omnivores, vegetarians, and vegans: results from a cross-sectional analysis of the EPIC-Oxford cohort study

    Science.gov (United States)

    Gilsing, Anne MJ; Crowe, Francesca L; Lloyd-Wright, Zouë; Sanders, Thomas AB; Appleby, Paul N; Allen, Naomi E; Key, Timothy J

    2010-01-01

    Background/Objectives Vegans and to a lesser extent vegetarians have low average circulating concentrations of vitamin B12; however, the relation between factors such as age or time on these diets and vitamin B12 concentrations is not clear. The objectives were to investigate differences in serum vitamin B12 and folate concentrations between omnivores, vegetarians and vegans and to ascertain whether vitamin B12 concentrations differed by age and time on the diet. Subjects/Methods A cross-sectional analysis involving 689 men (226 omnivores, 231 vegetarians and 232 vegans) from the European Prospective Investigation into Cancer and Nutrition Oxford cohort. Results Mean serum vitamin B12 was highest among omnivores (281, 95% CI: 270-292 pmol/l), intermediate in vegetarians (182, 95% CI: 175-189 pmol/l), and lowest in vegans (122, 95% CI: 117-127 pmol/l). Fifty-two percent of vegans, 7% of vegetarians and one omnivore were classified as vitamin B12 deficient (defined as serum vitamin B12 vegan diet and serum vitamin B12. In contrast, folate concentrations were highest among vegans, intermediate in vegetarians, and lowest in omnivores, but only two men (both omnivores) were categorised as folate deficient (defined as serum folate Vegans have lower vitamin B12 concentrations, but higher folate concentrations, than vegetarians and omnivores. Half of the vegans were categorised as vitamin B12 deficient and would be expected to have a higher risk of developing clinical symptoms related to vitamin B12 deficiency. PMID:20648045