WorldWideScience

Sample records for low-voltage mains verteilte

  1. Telecontrol and telemanagement over low voltage mains distribution network. Telemeting en telebesturing via het elektriciteitsnet

    Energy Technology Data Exchange (ETDEWEB)

    Homer, G [Thorn Security Ltd., London (UK); De Snoo, J K [Intechmij BV, Diemen (Netherlands)

    1990-11-01

    Mainsborne Telecontrol, now being manufactured by Thorn Security Ltd., is an integrated system for automatic meter reading, intelligent load control and real time feedback. The system is designed to respond to today's economic, social and political pressures for the better use of energy, reduced operating costs and greater customer satisfaction. Research and the application of modern electronics technology to solving the problems for achieving reliable two-way data communication over low voltage mains distribution network had opened up significant opportunities for supply authorities to provide a new range of services, aiding both themselves and their customers. London Electricity is now introducing tried, tested and available technology. 2 figs.

  2. Surge currents and voltages at the low voltage power mains during lightning strike to a GSM tower

    Energy Technology Data Exchange (ETDEWEB)

    Markowska, Renata [Bialystok Technical University (Poland)], E-mail: remark@pb.edu.pl

    2007-07-01

    The paper presents the results of numerical calculations of lightning surge currents and voltages in the low voltage power mains system connected to a free standing GSM base station. Direct lightning strike to GSM tower was studied. The analysis concerned the current that flows to the transformer station through AC power mains, the potential difference between the grounding systems of the GSM and the transformer stations and the voltage differences between phase and PE conductors of the power mains underground cable at both the GSM and the transformer sides. The calculations were performed using a numerical program based on the electromagnetic field theory and the method of moments. (author)

  3. Controlled storage for distributed power generation and optimised energy flow in low-voltage mains; Steuerbare Speicher zur Optimierung des Energieflusses in Niederspannungsnetzen mit DEA

    Energy Technology Data Exchange (ETDEWEB)

    Hoeckel, M.; Vollenwyder, R. [Berner Fachhochschule, Hochschule fuer Technik und Informatik (BFH-HTI), Biel (Switzerland); Buholzer, M.; Kreyenbuehl, U. [RIPEnergy AG, Zollikon (Switzerland); Schnyder, G.; Mauchle, P. [Schnyder Ingenieure AG, Huenenberg (Switzerland)

    2005-07-01

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) examines ways to optimise energy flows in mains networks that include distributed generation facilities. Increasing use of decentralised generation, its effects on the operation of low-voltage mains and the efficient use of the 400 V mains is discussed. The principles of operation and construction of controlled storage installations are discussed and concrete examples of their use in both grid-connected and island operation are quoted. Alternatives to storage are looked at from both the technical and economic points of view. The storage technologies used such as flywheels, supercaps, redox-flow batteries and lead-acid accumulators are briefly assessed and the results of simulations are discussed.

  4. Low-voltage gyrotrons

    International Nuclear Information System (INIS)

    Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S.; Nusinovich, G. S.

    2013-01-01

    For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5–10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%–2% in the submillimeter wavelength region).

  5. Observability of Low Voltage grids

    DEFF Research Database (Denmark)

    Martin-Loeches, Ruben Sánchez; Iov, Florin; Kemal, Mohammed Seifu

    2017-01-01

    Low Voltage (LV) distribution power grids are experiencing a transformation from a passive to a more active role due to the increasing penetration of distributed generation, heat pumps and electrical vehicles. The first step towards a smarter operation of LV electrical systems is to provide grid ...... an updated state of the art on DSSE-AMI based, adaptive data collection techniques and database management system types. Moreover, the ongoing Danish RemoteGRID project is presented as a realistic case study.......Low Voltage (LV) distribution power grids are experiencing a transformation from a passive to a more active role due to the increasing penetration of distributed generation, heat pumps and electrical vehicles. The first step towards a smarter operation of LV electrical systems is to provide grid....... It becomes unrealistic to provide near real time full observability of the LV grid by applying Distribution System State Estimation (DSSE) utilizing the classical data collection and storage/preprocessing techniques. This paper investigates up-todate the observability problem in LV grids by providing...

  6. Protection of Low Voltage CIGRE distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Bak, Claus Leth

    2013-01-01

    High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is protection of the system which needs to be fast, reliable and cost effective. The study about the protection of the Low Voltage (LV) CIGRE distribution...... grid and networks like this has been proposed in this paper. The main objective of this paper is to develop protection against short circuit faults which might appear any-where in the network. The protection of the power networks that comprises of renewable energy generation units is complicated...... because of the bidirectional flow of the current and is a challenge for the protection engineers. The selection of the protection devices in this paper is made to protect the network against faults in grid connected and island mode of operation. Ultra-fast fuses are proposed in order to protect...

  7. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical

  8. Bootstrapped Low-Voltage Analog Switches

    DEFF Research Database (Denmark)

    Steensgaard-Madsen, Jesper

    1999-01-01

    Novel low-voltage constant-impedance analog switch circuits are proposed. The switch element is a single MOSFET, and constant-impedance operation is obtained using simple circuits to adjust the gate and bulk voltages relative to the switched signal. Low-voltage (1-volt) operation is made feasible...

  9. Low Power/Low Voltage Interface Circuitry for Capacitive Sensors

    DEFF Research Database (Denmark)

    Furst, Claus Efdmann

    This thesis focuses mainly on low power/low voltage interface circuits, implemented in CMOS, for capacitive sensors. A brief discussion of demands and possibilities for analog signal processing in the future is presented. Techniques for low power design is presented. This is done by analyzing power...... power consumption. It is shown that the Sigma-Delta modulator is advantageous when embedded in a feedback loop with a mechanical sensor. Here a micro mechanical capacitive microphone. Feedback and detection circuitry for a capacitive microphone is presented. Practical implementations of low power....../low voltage interface circuitry is presented. It is demonstrated that an amplifier optimized for a capacitive microphone implemented in a standard 0.7 micron CMOS technology competes well with a traditional JFET amplifier. Furthermore a low power/low voltage 3rd order Sigma-Delta modulator is presented...

  10. Extension algorithm for generic low-voltage networks

    Science.gov (United States)

    Marwitz, S.; Olk, C.

    2018-02-01

    Distributed energy resources (DERs) are increasingly penetrating the energy system which is driven by climate and sustainability goals. These technologies are mostly connected to low- voltage electrical networks and change the demand and supply situation in these networks. This can cause critical network states. Network topologies vary significantly and depend on several conditions including geography, historical development, network design or number of network connections. In the past, only some of these aspects were taken into account when estimating the network investment needs for Germany on the low-voltage level. Typically, fixed network topologies are examined or a Monte Carlo approach is used to quantify the investment needs at this voltage level. Recent research has revealed that DERs differ substantially between rural, suburban and urban regions. The low-voltage network topologies have different design concepts in these regions, so that different network topologies have to be considered when assessing the need for network extensions and investments due to DERs. An extension algorithm is needed to calculate network extensions and investment needs for the different typologies of generic low-voltage networks. We therefore present a new algorithm, which is capable of calculating the extension for generic low-voltage networks of any given topology based on voltage range deviations and thermal overloads. The algorithm requires information about line and cable lengths, their topology and the network state only. We test the algorithm on a radial, a loop, and a heavily meshed network. Here we show that the algorithm functions for electrical networks with these topologies. We found that the algorithm is able to extend different networks efficiently by placing cables between network nodes. The main value of the algorithm is that it does not require any information about routes for additional cables or positions for additional substations when it comes to estimating

  11. Low voltage arc formation in railguns

    Science.gov (United States)

    Hawke, R.S.

    1985-08-05

    A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

  12. DC injection into low voltage AC networks

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report summarises the results of a study investigating the impact of levels of injected DC current injections on a low voltage AC distribution network systems in order to recommend acceptable limits of DC from microgeneration. Relevant literature is reviewed, and the impact of DC levels in distribution transformers, transformer modelling, and instrumental transformers are discussed. The impact of DC in residual current devices (RCD) and in domestic electricity watt hour meters is examined along with DC enhanced corrosion, corrosion failure, and the measurement of DC current injection. Sources of DC injection outlined include DC from computer power supplies, network faults, geomagnetic phenomena, lighting circuits/dimmers, and embedded generators.

  13. Lightning-induced overvoltages in low-voltage systems

    Energy Technology Data Exchange (ETDEWEB)

    Hoeidalen, Hans Kristian

    1997-12-31

    Lightning-induced overvoltages (LIOs) are a main source of failures in low-voltage overhead line systems. This thesis deals mainly with calculations of LIOs aiming to enable the design of a proper voltage protection. Models for calculation of LIOs are adapted from the literature or developed based on measurements. The models used are believed to be fairly accurate for the first few microseconds, which is usually sufficient for predicting the maximum induced voltage in the system. The lightning channel is modelled by the Modified Transmission Line (MTL) model with the Transmission Line (TL) model as a special case. The coupling between the electrical fields from a lightning channel and an overhead line is modelled by Agrawal`s model. The attenuation of electrical fields over a lossy ground is modelled by Norton`s- or the Surface Impedance methods. The validity of all the applied models is analysed. In addition, measurements have been performed in order to develop models of distribution transformers and low-voltage power installation (LVPI) networks. Simple models of typical transformers and LVPIs are developed for calculations when specific data are unavailable. The practical range of values and its influence on the LIOs in a system is investigated. The main frequency range of interest related to LIOs is 10 kHz - 1 MHz in which all the models are accurate. The adapted or developed models are used to calculate LIOs in low-voltage systems. The influence of various key parameters in the system is investigated. Most important are the return stroke amplitude and rise time, the overhead line height and location, the termination of overhead line segments, neutral grounding, and the ground conductivity. 135 refs., 136 figs., 12 tabs.

  14. Modular low-voltage electron beams

    International Nuclear Information System (INIS)

    Berejka, A.J.; Avnery, Tovi; Carlson, Carl

    2004-01-01

    Modular, low-voltage systems have simplified electron beam (EB) technology for industrial uses and for research and development. Modular EB units are produced in quantity as sealed systems that are evacuated at the factory eliminating the need for vacuum pumps at the point of use. A simple plug-out--plug-in method of replacement eliminates downtime for servicing. Use of ultra-thin beam windows (<10 μm of titanium foil), solid-state 19 in. (48 cm) rack-mounted power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, combine for ease of use and electrical transfer efficiency at voltages that can be varied between 80 and 150 kV and with high beam currents (up to 40 mA across the 25 cm window). These electron systems are available in three widths, the standard 25 cm and new 5 and 40 cm beams. Traditional uses in the graphic arts and coatings areas as well as uses in surface sterilization have found these compact, lightweight (approximately 15 kg) modular beams of interest. Units have been configured around complex shapes to enable three-dimensional surface curing (as for coatings on aluminum tubing) to be achieved at high production rates. Details of the beam construction and some industrial uses are discussed

  15. Modular low-voltage electron emitters

    International Nuclear Information System (INIS)

    Berejka, Anthony J.

    2005-01-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates

  16. Modular low-voltage electron emitters

    Science.gov (United States)

    Berejka, Anthony J.

    2005-12-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates.

  17. Modular low-voltage electron beams

    Science.gov (United States)

    Berejka, Anthony J.; Avnery, Tovi; Carlson, Carl

    2004-09-01

    Modular, low-voltage systems have simplified electron beam (EB) technology for industrial uses and for research and development. Modular EB units are produced in quantity as sealed systems that are evacuated at the factory eliminating the need for vacuum pumps at the point of use. A simple plug-out—plug-in method of replacement eliminates downtime for servicing. Use of ultra-thin beam windows (innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, combine for ease of use and electrical transfer efficiency at voltages that can be varied between 80 and 150 kV and with high beam currents (up to 40 mA across the 25 cm window). These electron systems are available in three widths, the standard 25 cm and new 5 and 40 cm beams. Traditional uses in the graphic arts and coatings areas as well as uses in surface sterilization have found these compact, lightweight (approximately 15 kg) modular beams of interest. Units have been configured around complex shapes to enable three-dimensional surface curing (as for coatings on aluminum tubing) to be achieved at high production rates. Details of the beam construction and some industrial uses are discussed.

  18. Methodology for the assessment of possible damages in low voltage equipment due to lightning surges

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Nelson M.; Kagan, Nelson [University of Sao Paulo (USP), SP (Brazil)], Emails: matsuonm@usp.br, nelsonk@pea.usp.br; Domingues, Ivo T. [AES Eletropaulo, SP (Brazil); Jesus, Nelson C. de [AES Sul, Porto Alegre, RS (Brazil); Silva, Marcelo H.I. da [Grupo Rede, Sao Paulo, SP (Brazil); Takauti, Edson H. [Bandeirante, Sao Paulo, SP (Brazil)

    2007-07-01

    This paper deals with the development of a methodology to assess the possibility of equipment damages in low voltage customers due to lightning surges. The main objective is to incorporate this methodology in a computation system that supports distribution companies to determine the possible causes of equipment damages claimed by customers and to decide whether the claims are to be reimbursed or not. The proposed methodology determines whether a specific customer could be affected by a lightning strike according to his/her location and to the lightning main parameters, by using data from a lightning detection system and from the specific equipment surge withstand capability. A specific study using ATP (Alternative Transients Program) was carried out to assess the propagation of lightning surges in electric power distribution systems and their impact over low voltage customers. On the other hand, the withstand capability of the main household appliances was determined by a series of tests carried out in the University's power quality laboratory. The paper details the modeling used for simulation, such as network configuration, grounding points, and modelling of insulator flashover, distribution transformer, low voltage loads. It also presents some results regarding the evaluation of over voltages in low voltage customers installations. A practical method is proposed for assessing the possibility of equipment damage and describes how the existing uncertainties were handled. Also, some issues regarding the withstand capability of electric household appliances to lightning surges are discussed and some results of the laboratory tests are presented. (author)

  19. Left atrial low-voltage areas predict atrial fibrillation recurrence after catheter ablation in patients with paroxysmal atrial fibrillation.

    Science.gov (United States)

    Masuda, Masaharu; Fujita, Masashi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Shota; Ohashi, Takuya; Tsuji, Aki; Mano, Toshiaki

    2018-04-15

    Association between the presence of left atrial low-voltage areas and atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been shown mainly in persistent AF patients. We sought to compare the AF recurrence rate in paroxysmal AF patients with and without left atrial low-voltage areas. This prospective observational study included 147 consecutive patients undergoing initial ablation for paroxysmal AF. Voltage mapping was performed after PVI during sinus rhythm, and low-voltage areas were defined as regions where bipolar peak-to-peak voltage was low-voltage areas after PVI were observed in 22 (15%) patients. Patients with low-voltage areas were significantly older (72±6 vs. 66±10, plow-voltage areas than without (36% vs. 6%, pLow-voltage areas were independently associated with AF recurrence even after adjustment for the other related factors (Hazard ratio, 5.89; 95% confidence interval, 2.16 to 16.0, p=0.001). The presence of left atrial low-voltage areas after PVI predicts AF recurrence in patients with paroxysmal AF as well as in patients with persistent AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    Any problem in voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM), Dynamic Voltage Restorer (DVR) etc. are commonly used for the mitigation of voltage p....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0.......Any problem in voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM), Dynamic Voltage Restorer (DVR) etc. are commonly used for the mitigation of voltage...... problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate voltage sags in the CIGRE Low Voltage (LV) test network and networks like this. The voltage sags, for the tested cases in the CIGRE LV test network are mainly due to three phase faults...

  1. Lightning Overvoltage on Low-Voltage Distribution System

    Science.gov (United States)

    Michishita, Koji

    The portion of the faults of a medium-voltage line, cause by lightning, tends to increase with often reaching beyond 30%. However, due to the recent progress of the lightning protection design, the number of faults has decreased to 1/3 of that at 30 years ago. As for the low-voltage distribution line, the fault rate has been estimated primarily, although the details of the overvoltages have not been studied yet. For the further development of highly information-oriented society, improvement of reliability of electric power supply to the appliance in a low-voltage customer will be socially expected. Therefore, it is important to establish effective lightning protection design of the low-voltage distribution system, defined to be composed of lines having mutual interaction on the customers' electric circuits, such as a low-voltage distribution line, an antenna line and a telecommunication line. In this report, the author interprets the recent research on the lightning overvoltage on a low-voltage distribution system.

  2. Technical solutions for low-voltage microgrid concept

    Energy Technology Data Exchange (ETDEWEB)

    Laaksonen, H.

    2011-07-01

    Future electricity distribution networks with large amount of distributed energy resources will require creation of a totally new smart grid architecture. The micro grid concept is expected to play a major role in the new smart grid architecture. A special feature of microgrids is that during disturbances in the utility grid they can continue operation automatically in the island mode so that electricity supply to microgrid customers can be continued without any interruption. Thereby, the microgrid concept allows the reliability benefit of distributed energy resources to be realized while also fulfilling the future energy efficiency requirements. In this thesis a total technical concept for low-voltage microgrid which could be integrated into the future smart grids has been developed and specified. The key technical challenges of low-voltage microgrids are the transition to island operation, the power quality management and the microgrid protection especially during island operation. Essential part of the concept development involved the development of solutions and operation principles to these key technical challenges of low-voltage microgrids so that all these solutions would be compatible with each other. The role of one central energy storage unit and the location of it are very important in the developed concept from the low-voltage microgrid management and protection point of view. The development work with the related technical challenges was carried out in this thesis with PSCAD simulation software. PSCAD enabled the examination of a simultaneous interaction of different types of distributed energy resource units and loads both in the normal utility grid connected and in the island operation mode of the microgrid. This information from simulations with multiple component configurations was essential when the technical solutions were developed and these studies could not have been undertaken to this extent in a laboratory environment without major

  3. Low-voltage CMOS operational amplifiers theory, design and implementation

    CERN Document Server

    Sakurai, Satoshi

    1995-01-01

    Low-Voltage CMOS Operational Amplifiers: Theory, Design and Implementation discusses both single and two-stage architectures. Opamps with constant-gm input stage are designed and their excellent performance over the rail-to-rail input common mode range is demonstrated. The first set of CMOS constant-gm input stages was introduced by a group from Technische Universiteit, Delft and Universiteit Twente, the Netherlands. These earlier versions of circuits are discussed, along with new circuits developed at the Ohio State University. The design, fabrication (MOSIS Tiny Chips), and characterization of the new circuits are now complete. Basic analog integrated circuit design concepts should be understood in order to fully appreciate the work presented. However, the topics are presented in a logical order and the circuits are explained in great detail, so that Low-Voltage CMOS Operational Amplifiers can be read and enjoyed by those without much experience in analog circuit design. It is an invaluable reference boo...

  4. Ultra-Low Voltage Class AB Switched Current Memory Cell

    DEFF Research Database (Denmark)

    Igor, Mucha

    1996-01-01

    This paper presents the theoretical basis for the design of class AB switched current memory cells employing floating-gate MOS transistors, suitable for ultra-low-voltage applications. To support the theoretical assumptions circuits based on these cells were designed using a CMOS process with thr......This paper presents the theoretical basis for the design of class AB switched current memory cells employing floating-gate MOS transistors, suitable for ultra-low-voltage applications. To support the theoretical assumptions circuits based on these cells were designed using a CMOS process...... with threshold voltages of 0.9V. Both hand calculations and PSPICE simulations showed that the cells designed allowed a maximum signal range better than +/-13 micoamp, with a supply voltage down to 1V and a quiescent bias current of 1 microamp, resulting in a very high current efficiency and effective power...

  5. Characterization of a low-voltage electron beam

    International Nuclear Information System (INIS)

    Berejka, A.J.

    2004-01-01

    Growing interests in low-voltage electron beam (EB) processing in areas that may require regulatory compliance, such as the curing of inks and coatings for food packaging materials and in the surface disinfection of medicinal and food containers, lead to the characterization of a low-voltage EB by two methods: a widely used thin radiochromic film and a film strip made on a continuous basis with an alanine coating. Using a laboratory unit, beam currents and voltages were varied and then optical density and alanine/matrix ratios were, respectively, determined. No inferences as to 'dose' were made. The radiochromic film was found to be insensitive to slight changes at low beam currents and to show considerable divergence and a broadening in response as current was increased across a meaningful range at the three applied beam voltages of 80, 100 and 120 kV. The electron paramagnetic resonance (EPR) increase in response of the alanine coated film taken as a ratio to an internal reference material within the test instrument itself was shown to have a linear response with respect to beam current and no divergence as current increased. The use of an alanine coating of thickness greater than that of the extrapolated range of the electron penetration offers a method for the characterization of the output of such very low-voltage beams

  6. Low-voltage circuit breaker arcs—simulation and measurements

    International Nuclear Information System (INIS)

    Yang, Fei; Wu, Yi; Rong, Mingzhe; Sun, Hao; Ren, Zhigang; Niu, Chunping; Murphy, Anthony B

    2013-01-01

    As one of the most important electrical components, the low-voltage circuit breaker (LVCB) has been widely used for protection in all types of low-voltage distribution systems. In particular, the low-voltage dc circuit breaker has been arousing great research interest in recent years. In this type of circuit breaker, an air arc is formed in the interrupting process which is a 3D transient arc in a complex chamber geometry with splitter plates. Controlling the arc evolution and the extinction are the most significant problems. This paper reviews published research works referring to LVCB arcs. Based on the working principle, the arcing process is divided into arc commutation, arc motion and arc splitting; we focus our attention on the modelling and measurement of these phases. In addition, previous approaches in papers of the critical physical phenomenon treatment are discussed, such as radiation, metal erosion, wall ablation and turbulence in the air arc. Recommendations for air arc modelling and measurement are presented for further investigation. (topical review)

  7. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  8. Dynamic range of low-voltage cascode current mirrors

    DEFF Research Database (Denmark)

    Bruun, Erik; Shah, Peter Jivan

    1995-01-01

    Low-voltage cascode current mirrors are reviewed with respect to the design limitations imposed if all transistors in the mirror are required to operate in the saturation region. It is found that both a lower limit and an upper limit exist for the cascode transistor bias voltage. Further, the use....... The proposed configuration has the advantage of simplicity combined with a complete elimination of the need for fixed bias voltages or bias currents in the current mirror. A disadvantage is that it requires a higher input voltage to the current mirror...

  9. Symmetric low-voltage powering system for relativistic electronic devices

    International Nuclear Information System (INIS)

    Agafonov, A.V.; Lebedev, A.N.; Krastelev, E.G.

    2005-01-01

    A special driver for double-sided powering of relativistic magnetrons and several methods of localized electron flow forming in the interaction region of relativistic magnetrons are proposed and discussed. Two experimental installations are presented and discussed. One of them is designed for laboratory research and demonstration experiments at a rather low voltage. The other one is a prototype of a full-scale installation for an experimental research at relativistic levels of voltages on the microwave generation in the new integrated system consisting of a relativistic magnetron and symmetrical induction driver

  10. Evolution of graphene nanoribbons under low-voltage electron irradiation

    KAUST Repository

    Zhu, Wenpeng

    2012-01-01

    Though the all-semiconducting nature of ultrathin graphene nanoribbons (GNRs) has been demonstrated in field-effect transistors operated at room temperature with ∼105 on-off current ratios, the borderline for the potential of GNRs is still untouched. There remains a great challenge in fabricating even thinner GNRs with precise width, known edge configurations and specified crystallographic orientations. Unparalleled to other methods, low-voltage electron irradiation leads to a continuous reduction in width to a sub-nanometer range until the occurrence of structural instability. The underlying mechanisms have been investigated by the molecular dynamics method herein, combined with in situ aberration-corrected transmission electron microscopy and density functional theory calculations. The structural evolution reveals that the zigzag edges are dynamically more stable than the chiral ones. Preferential bond breaking induces atomic rings and dangling bonds as the initial defects. The defects grow, combine and reconstruct to complex edge structures. Dynamic recovery is enhanced by thermal activation, especially in cooperation with electron irradiation. Roughness develops under irradiation and reaches a plateau less than 1 nm for all edge configurations after longtime exposure. These features render low-voltage electron irradiation an attractive technique in the fabrication of ultrathin GNRs for exploring the ultimate electronic properties. © 2012 The Royal Society of Chemistry.

  11. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    DEFF Research Database (Denmark)

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis...

  12. A Generalised Fault Protection Structure Proposed for Uni-grounded Low-Voltage AC Microgrids

    Science.gov (United States)

    Bui, Duong Minh; Chen, Shi-Lin; Lien, Keng-Yu; Jiang, Jheng-Lun

    2016-04-01

    This paper presents three main configurations of uni-grounded low-voltage AC microgrids. Transient situations of a uni-grounded low-voltage (LV) AC microgrid (MG) are simulated through various fault tests and operation transition tests between grid-connected and islanded modes. Based on transient simulation results, available fault protection methods are proposed for main and back-up protection of a uni-grounded AC microgrid. In addition, concept of a generalised fault protection structure of uni-grounded LVAC MGs is mentioned in the paper. As a result, main contributions of the paper are: (i) definition of different uni-grounded LVAC MG configurations; (ii) analysing transient responses of a uni-grounded LVAC microgrid through line-to-line faults, line-to-ground faults, three-phase faults and a microgrid operation transition test, (iii) proposing available fault protection methods for uni-grounded microgrids, such as: non-directional or directional overcurrent protection, under/over voltage protection, differential current protection, voltage-restrained overcurrent protection, and other fault protection principles not based on phase currents and voltages (e.g. total harmonic distortion detection of currents and voltages, using sequence components of current and voltage, 3I0 or 3V0 components), and (iv) developing a generalised fault protection structure with six individual protection zones to be suitable for different uni-grounded AC MG configurations.

  13. A wiggler magnet for FEL low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Al-Shamma`a, A.; Stuart, R.A.; Lucas, J.

    1995-12-31

    In low voltage FELs (ie, 200kV), operation is necessarily in the microwave frequency range for wiggler periods of the order of cms., so that a waveguide system is mandatory. Also, because of the relatively low velocity of the electron beam, the wiggle amplitude of the electron beam can be much larger than is normal for highly relativistic FELs. Both these factors mean that the electron trajectory must be carefully controlled to avoid beam collision with the waveguide walls. A wiggler system with half poles at entrance and exit is not an acceptable solution because of the offset is gives rise to the electron trajectory. Consequently, we have designed and constructed a wiggler magnet with exponential entrance and exit tapers for a minimal deflection and displacement of the electron beam. Simulations and experimental measurements showed that an on axis trajectory is easily obtainable.

  14. Innovative energy efficient low-voltage electron beam emitters

    International Nuclear Information System (INIS)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-01-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates

  15. Innovative energy efficient low-voltage electron beam emitters

    Science.gov (United States)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-03-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates.

  16. Review of mixer design for low voltage - low power applications

    Science.gov (United States)

    Nurulain, D.; Musa, F. A. S.; Isa, M. Mohamad; Ahmad, N.; Kasjoo, S. R.

    2017-09-01

    A mixer is used in almost all radio frequency (RF) or microwave systems for frequency translation. Nowadays, the increase market demand encouraged the industry to deliver circuit designs to create proficient and convenient equipment with very low power (LP) consumption and low voltage (LV) supply in both digital and analogue circuits. This paper focused on different Complementary Metal Oxide Semiconductor (CMOS) design topologies for LV and LP mixer design. Floating Gate Metal Oxide Semiconductor (FGMOS) is an alternative technology to replace CMOS due to their high ability for LV and LP applications. FGMOS only required a few transistors per gate and can have a shift in threshold voltage (VTH) to increase the LP and LV performances as compared to CMOS, which makes an attractive option to replace CMOS.

  17. A nanoscale piezoelectric transformer for low-voltage transistors.

    Science.gov (United States)

    Agarwal, Sapan; Yablonovitch, Eli

    2014-11-12

    A novel piezoelectric voltage transformer for low-voltage transistors is proposed. Placing a piezoelectric transformer on the gate of a field-effect transistor results in the piezoelectric transformer field-effect transistor that can switch at significantly lower voltages than a conventional transistor. The piezoelectric transformer operates by using one piezoelectric to squeeze another piezoelectric to generate a higher output voltage than the input voltage. Multiple piezoelectrics can be used to squeeze a single piezoelectric layer to generate an even higher voltage amplification. Coupled electrical and mechanical modeling in COMSOL predicts a 12.5× voltage amplification for a six-layer piezoelectric transformer. This would lead to more than a 150× reduction in the power needed for communications.

  18. Integration of Electric Vehicles in Low Voltage Danish Distribution Grids

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Thøgersen, Paul; Møller, Jan

    2012-01-01

    Electric Vehicles (EVs) are considered as one of the important components of the future intelligent grids. Their role as energy storages in the electricity grid could provide local sustainable solutions to support more renewable energy. In order to estimate the extent of interaction of EVs...... in the electricity grid operation, a careful examination in the local electricity system is essential. This paper investigates the degree of EV penetration and its key influence on the low voltage distribution grids. Three detailed models of residential grids in Denmark are considered as test cases in this study...... it is shown that there is enough head-space on the transformer capacity which can be used to charge many EVs during a day. The overall transformer capability of handling EV loads varies between 6-40% for peak and minimum demand hours, which is dependent on the robustness of the grids. The voltage drops...

  19. Load Insensitive, Low Voltage Quadrature Oscillator Using Single Active Element

    Directory of Open Access Journals (Sweden)

    Jitendra Mohan

    2017-01-01

    Full Text Available In this paper, a load insensitive quadrature oscillator using single differential voltage dual-X second generation current conveyor operated at low voltage is proposed. The proposed circuit employs single active element, three grounded resistors and two grounded capacitors. The proposed oscillator offers two load insensitive quadrature current outputs and three quadrature voltage outputs simultaneously. Effects of non-idealities along with the effects of parasitic are further studied. The proposed circuit enjoys the feature of low active and passive sensitivities. Additionally, a resistorless realization of the proposed quadrature oscillator is also explored. Simulation results using PSPICE program on cadence tool using 90 nm Complementary Metal Oxide Semiconductor (CMOS process parameters confirm the validity and practical utility of the proposed circuit.

  20. Electrical and optical investigations on the low voltage vacuum arc

    International Nuclear Information System (INIS)

    Braic, M.; Braic, V.; Pavelescu, G.; Balaceanu, M.; Pavelescu, D.; Dumitrescu, G.; Gherendi, F.

    2002-01-01

    Preliminary investigations of a low voltage circuit breaker, adapted from a real industrial device, were carried out by electrical and optical methods. Electrical, parameters were measured in the high current arc period and in zero current moment (C.Z) and corroborated with the arc plasma spectroscopic investigations. For the first time in vacuum arc diagnostics, the paper presents results based on single shot time resolved emission spectroscopy around C.Z. The short-circuit current was produced in a special high power installation in order to reproduce exactly the short-circuit regimes developing in low voltage distribution networks. A stainless steel vacuum chamber with classical Cu-Cr electrodes was used. Tests were performed for different current values in the range 3 - 20 kA rms , the voltages being varied between 200 and 1000 V ac . Interruption processes in the different arc regimes (from the diffuse arc mode to the constricted column mode) were analyzed. The success of the arc interruption was analyzed in terms of electric arc energy achieved in the first current halfperiod. The results obtained were corroborated with arc plasma spectroscopic investigations. The emission spectroscopy setup, using an Acton spectrograph and an intensified CCD camera, allowed the spatial and time-resolved investigation of spectra emitted by the vacuum arc plasma. The first truly time-resolved spectroscopic measurements on a single half-period was proven to be a good method to investigate the vacuum arc. Using single shot time resolved spectroscopy around zero current on partial unsuccessful interruption we concluded that the Cu ions, more that Cr ions were responsible for the arc reignition. The financial support for this work comes from NATO-STI SfP /974083 and CORINT-Romania projects. (authors)

  1. Successful application of Low Voltage Electron Microscopy to practical materials problems

    International Nuclear Information System (INIS)

    Bell, David C.; Mankin, Max; Day, Robert W.; Erdman, Natasha

    2014-01-01

    Low-voltage High-Resolution Electron Microscopy (LVHREM) has several advantages, including increased cross-sections for inelastic and elastic scattering, increased contrast per electron, decreased delocalization effects and reduced knock-on damage. Imaging at differing voltages has shown advantages for imaging materials that are knock-on damage sensitive. We show experimentally that different materials systems benefit from low voltage high-resolution microscopy. There are advantages for imaging single layer materials such as graphene at below the knock-on threshold; we present an example of imaging a graphene sheet at 40 kV. We have also examined mesoporous silica decorated with Pd nanoparticles and carbon black functionalized with Pd/Pt nanoparticles. In these cases we show that the lower voltage imaging maintains the structure of the surrounding matrix during imaging, whereas aberration correction provides the higher resolution for imaging the nanoparticle lattice. Perhaps surprisingly we show that zeolites damage preferentially by ionization effects (radiolysis). The current literature suggests that below incident energies of 40 kV the damage is mainly radiolitic, whereas at incident energies above 200 kV the knock-on damage and material sputtering will be the dominant effect. Our experimental observations support this conclusion and the effects we have observed at 40 kV are not indicative of knock-on damage. Other nanoscale materials such as thin silicon nanowires also benefit from lower voltage imaging. LVHREM imaging provides an excellent option to avoid beam damage to nanowires; our results suggest that LVHREM is suitable for nanowire-biological composites. Our experimental observations serve as a clear demonstration that even at 40 keV accelerating voltage, LVHREM can be used without inducing beam damage to locate dislocations and other crystalline defects, which may have adverse effects on nanowire device performance. Low voltage operation will likely

  2. Fully low voltage and large area searching scanning tunneling microscope

    International Nuclear Information System (INIS)

    Pang, Zongqiang; Wang, Jihui; Lu, Qingyou

    2009-01-01

    We present a novel scanning tunneling microscope (STM), which allows the tip to travel a large distance (millimeters) on the sample and take images (to find microscopic targets) anywhere it reaches without losing atomic resolution. This broad range searching capability, together with the coarse approach and scan motion, is all done with only one single piezoelectric tube scanner as well as with only low voltages (<15 V). Simple structure, low interference and high precision are thus achieved. To this end, a pillar and a tube scanner are mounted in parallel on a base with one ball glued on the pillar top and two balls glued on the scanner top. These three balls form a narrow triangle, which supports a triangular slider piece. By inertial stepping, the scanner can move the slider toward the pillar (coarse approach) or rotate the slider about the pillar (travel along sample surface). Since all the stepping motions are driven by the scanner's lateral bending which is large per unit voltage, high voltages are unnecessary. The technology is also applicable to scanning force microscopes (SFM) such as atomic force microscopes (AFM), etc

  3. Baking of tandem accelerator tube by low voltage arc discharge

    International Nuclear Information System (INIS)

    Nakajima, Yutaka

    1982-01-01

    In designing the accelerating tube for a static tandem accelerator in Kyushu University, the basic policy was as described below: individual unit composing the accelerating tube should fully withstand the electric field of 2 MV/m, and electric discharge must not be propagated from one unit to the adjacent unit when these are assembled to the accelerating tube. The accelerating tube units are each 25 cm in length, and both high and low energy sides are composed of 20 units, respectively. Although about 10 -9 Torr vacuum was obtained at the both ends of the accelerating tube by baking the tube at 300 to 350 deg C with electric heaters wound outside the tube in the conventional method, vast outgas was generated, which decreased vacuum by two or three figures if breakdown occurred through the intermediary of outgas. As a method of positively outgassing and cleaning the electrodes inside the accelerating tube, it was attempted to directly bake all the electrodes in the accelerating tube by causing strong arc discharge flowing H 2 gas in the tube. As a result of considering the conditions for this method, the low voltage arc discharge was employed using oxide cathodes. Thus, after implementing 10A arc discharge for several hours, the voltage was able to be raised to 10 MV almost immediately after the vacuum recovery, and further, after another conditioning for several hours, it was successful to raise voltage up to 11 MV. (Wakatsuki, Y.)

  4. Life testing of a low voltage air circuit breaker

    International Nuclear Information System (INIS)

    Subudhi, M.

    1991-01-01

    ADS-416 low voltage air circuit breaker manufacture by Westinghouse was mechanically cycled to identify age-related degradation in various breaker subcomponents, in particular, the power-operating mechanism. This accelerated aging test was performed on one breaker unit for over 36,000 cycles. Three separate pole shafts, one with a 60 degree weld, one with a 120 degree weld and one with a 180 degree weld in the third pole lever were used to characterize the cracking in these welds. In addition, during the testing, three different operating mechanisms and several other parts were replaced as they degraded to an inoperable condition. Of the seven welds on the pole shaft, two were found to be the critical ones whose fracture can result in misalignment problems of the pole levers. These failures, in turn can lead to many other problems with the operating mechanism including the burn-out of coils, excessive wear in certain parts and over-stressed linkages. Furthermore, the limiting service life of a number of subcomponents of the power-operated mechanism, including the operating mechanism itself, were assessed. 1 ref., 3 figs

  5. Life testing of a low voltage air circuit breaker

    International Nuclear Information System (INIS)

    Subudhi, M.; Aggarwal, S.

    1992-01-01

    A DS-416 low voltage air circuit breaker manufactured by Westinghouse was mechanically cycled to identify age-related degradation in the various breaker subcomponents, specifically the power-operated mechanism. This accelerated aging test was performed on one breaker unit for over 36,000 cycles. Three separate pole shafts, one with a 60-degree weld, one with a 120-degree weld, and one with a 180-degree weld in the third pole lever were used to characterize cracking in the welds. In addition, during the testing three different operating mechanisms and several other parts were replaced as they became inoperable. Among the seven welds on the pole shaft, number-sign 1 and number-sign 3 were found to be critical ones whose fracture can result in misalignment of the pole levers. This can lead to problems with the operating mechanism, including the burning of coils, excessive wear in certain parts, and overstressed linkages. Furthermore, the limiting service life of a number of subcomponents of the power-operated mechanism, including the operating mechanism itself, were assessed. Based on these findings, suggestions are provided to alleviate the age-related degradation that could occur as a result of normal closing and opening of the breaker contacts during its service life. Also, cause and effect analyses of various age-related degradation in various breaker parts are discussed

  6. Low-voltage electricity-induced lung injury.

    Science.gov (United States)

    Truong, Thai; Le, Thuong Vu; Smith, David L; Kantrow, Stephen P; Tran, Van Ngoc

    2018-02-01

    We report a case of bilateral pulmonary infiltrates and haemoptysis following low-voltage electricity exposure in an agricultural worker. A 58-year-old man standing in water reached for an electric watering machine and sustained an exposure to 220 V circuit for an uncertain duration. The electricity was turned off by another worker, and the patient was asymptomatic for the next 10 h until he developed haemoptysis. A chest radiograph demonstrated bilateral infiltrates, and chest computed tomography (CT) revealed ground-glass opacities with interstitial thickening. Evaluations, including electrocardiogram, serum troponin, N-terminal pro-B-type natriuretic peptide (NT-pro BNP), coagulation studies, and echocardiogram, found no abnormality. The patient was treated for suspected electricity-induced lung injury and bleeding with tranexamic acid and for rhabdomyolysis with volume resuscitation. He recovered with complete resolution of chest radiograph abnormalities by Day 7. This is the first reported case of bilateral lung oedema and/or injury after electricity exposure without cardiac arrest.

  7. Development of a prototype solid state fault current limiting and interrupting device for low voltage distribution networks.

    OpenAIRE

    Ahmed, M.; Putrus, G. A.; Ran, L.; Penlington, R.

    2006-01-01

    This paper describes the development of a solid-state Fault Current Limiting and Interrupting Device (FCLID) suitable for low voltage distribution networks. The main components of the FCLID are a bidirectional semiconductor switch that can disrupt the short-circuit current, and a voltage clamping element that helps in controlling the current and absorbing the inductive energy stored in the network during current interruption. Using a hysteresis type control algorithm, the short-circuit curren...

  8. Low Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    The progressively growing of single-phase photovoltaic (PV) systems makes the Distribution System Operators (DSO) to update or revise the existing grid codes in order to guarantee the availability, quality and reliability of the electrical system. It is expected that the future PV systems connected...... to the low-voltage grid will be more active with functionalities of low voltage ride-through (LVRT) and the grid support capability, which is not the case today. In this paper, the operation principle is demonstrated for a single-phase grid-connected PV system in low voltage ride through operation in order...... to map future challenges. The system is verified by simulations and experiments. Test results show that the proposed power control method is effective and the single-phase PV inverters connected to low-voltage networks are ready to provide grid support and ride-through voltage fault capability...

  9. Small Distributed Renewable Energy Generation for Low Voltage Distribution Networks

    Directory of Open Access Journals (Sweden)

    Chindris M.

    2016-08-01

    Full Text Available Driven by the existing energy policies, the use of renewable energy has increased considerably all over the world in order to respond to the increasing energy consumption and to reduce the environmental impact of the electricity generation. Although most policy makers and companies are focusing on large applications, the use of cheap small generation units, based on local renewable resources, has become increasingly attractive for the general public, small farms and remote communities. The paper presents several results of a research project aiming to identify the power quality issues and the impact of RES based distributed generation (DG or other non-linear loads on low voltage (LV distribution networks in Romania; the final goal is to develop a Universal Power Quality Conditioner (UPQC able to diminish the existing disturbances. Basically, the work analyses the existing DG technologies and identifies possible solutions for their integration in Romania; taking into account the existent state of the art, the attention was paid on small systems, using wind and solar energy, and on possibility to integrate them into suburban and rural LV distribution networks. The presence of DG units at distribution voltage level means the transition from traditional passive to active distribution networks. In general, the relatively low penetration levels of DG does not produce problems; however, the nowadays massive increase of local power generation have led to new integration challenges in order to ensure the reliability and quality of the power supply. Power quality issues are identified and their assessment is the key element in the design of measures aiming to diminish all existing disturbances.

  10. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system...... to unbalanced faults. The compensation of unbalanced voltage sags and voltage unbalance in the CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0........ The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and net-works like this. The voltage unbalances, for the tested cases in the CIGRE LV test network are mainly due to single phase loads and due...

  11. Selective electromembrane extraction at low voltages based on analyte polarity and charge

    DEFF Research Database (Denmark)

    Domínguez, Noelia Cabaleiro; Gjelstad, Astrid; Nadal, Andrea Molina

    2012-01-01

    Electromembrane extraction (EME) at low voltage (0-15V) of 29 different basic model drug substances was investigated. The drug substances with logP......Electromembrane extraction (EME) at low voltage (0-15V) of 29 different basic model drug substances was investigated. The drug substances with logP...

  12. Plasma diagnostics with electrostatic probes in the reactive low voltage ion plating process

    International Nuclear Information System (INIS)

    Lechleitner, T.; Huber, D.; Pulker, H.K.

    2002-01-01

    The analysis of cold plasmas, which are used in thin film coating techniques, is mainly important for the understanding of the correlation between the film properties and the plasma (or the process) parameters. With the knowledge of these correlations, one is able to optimise and eventually improve the coating processes for the production of films with certain desirable properties. The plasma for the reactive-low-voltage-ion-plating processes is a cold non-isothermal plasma produced by a low-pressure dc non-self sustained arc discharge, controlled by two main parameters, the arc current and the total gas pressure in the chamber. It was shown that the arc current is in a direct linear relation to the degree of ionization and the increase of the total gas pressure has a contrary effect. Besides, it was also demonstrated, that the usage of electrostatic probes for the plasma analysis od deposition processes is a powerful tool to complete the common plasma monitor measurements (energy analysing quadrupol mass spectrometer) and to improve the understanding of industrially used plasma. (nevyjel)

  13. Recycling potential for low voltage and high voltage high rupturing capacity fuse links.

    Science.gov (United States)

    Psomopoulos, Constantinos S; Barkas, Dimitrios A; Kaminaris, Stavros D; Ioannidis, George C; Karagiannopoulos, Panagiotis

    2017-12-01

    Low voltage and high voltage high-rupturing-capacity fuse links are used in LV and HV installations respectively, protecting mainly the LV and HV electricity distribution and transportation networks. The Waste Electrical and Electronic Equipment Directive (2002/96/EC) for "Waste of electrical and electronic equipment" is the main related legislation and as it concerns electrical and electronic equipment, it includes electric fuses. Although, the fuse links consist of recyclable materials, only small scale actions have been implemented for their recycling around Europe. This work presents the possibilities for material recovery from this specialized industrial waste for which there are only limited volume data. Furthermore, in order to present the huge possibilities and environmental benefits, it presents the potential for recycling of HRC fuses used by the Public Power Corporation of Greece, which is the major consumer for the country, but one of the smallest ones in Europe and globally, emphasizing in this way in the issue. According to the obtained results, fuse recycling could contribute to the effort for minimize the impacts on the environment through materials recovery and reduction of the wastes' volume disposed of in landfills. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Simulation and Experimental Study of Arc Column Expansion After Ignition in Low-Voltage Circuit Breakers

    Institute of Scientific and Technical Information of China (English)

    MA Qiang; RONG Mingzhe; WU Yi; XU Tiejun; SUN Zhiqiang

    2008-01-01

    The dynamicprocess of arc pressure and corresponding arc column expansion, which is the main feature after arc ignition and has a significant effect on the breaking behaviour of low -voltage circuit breakers, is studied. By constructing a three dimensional mathematical model of air arc plasma and adopting the Control Volume Method, the parameters of arc plasma including temperature and pressure axe obtained. The variations of pressure field and temperature field with time are simulated. The result indicates that there are six stages for the process of arc column expansion according to the variation of pressure in arc chamber. In the first stage, the maximal pressure locates in the region close to cathode, and in the second stage the maximal pressure shifts to the region close to the anode. In the third stage, the pressure difference between the middle of arc column and the ambient gas is very large, so the arc column begins to expand apparently. In the fourth stage, the pressure wave propagates towards both ends and the maximal pressure appears at the two ends when the pressure wave reaches both sidewalls. In the fifth stage, the pressure wave is reflected and collides in the middle of the arc chamber. In the last stage, the propagation and reflection of pressure wave will repeat several times until a steady burning state is reached. In addition, the experimental results of arc column expansion, corresponding to the arc pressure variation, are presented to verify the simulation results.

  15. Evaluation of seismic resistance of low voltage switchgear, NPP V1 Jaslovske Bohunice, Slovakia

    International Nuclear Information System (INIS)

    Zeman, P.

    1999-01-01

    During this year, company Stevenson and Associates took part in the project of evaluation of seismic resistance of NPP V-1 Jaslovske Bohunice in Slovakia. It was responsible for a part of electrical equipment, mainly for the evaluation of low voltage switchgears. There were four steps of the evaluation: Detailed Walkdown; Application of GIP-WWER Methodology; Developing, of In Cabinet Response Spectra; and Evaluation of Acceptance of Formerly Performed Relay Tests According to the Russian Standard OEG l-330.00-3). Tests performed according to the Russian Standard OAG are acceptable only if the tested subject shows just one dominant natural frequency in the significant energy frequency range. If there is no knowledge of modal properties of the tested subject (that is a frequent situation because test reports usually contain only generalized Fourier loading spectrum) the enveloping of In Cabinet Response Spectra (ICRS) in all significant energy frequency ranges by Response Spectra (RS) of harmonic signal on one arbitrary frequency. This criteria is usually not satisfied because the shake tables used for the tests are not able to produce the sufficient level of excitation in the low frequency range. It may lead to the demand for test repeating

  16. Low-voltage Power Supply Subsystem for a Sub-Orbital Particle Physic Instrument

    Directory of Open Access Journals (Sweden)

    Hector Hugo Silva Lopez

    2014-01-01

    Full Text Available The Japanese Experiment Module–Extreme Universe Space Observatory (JEM-EUSO is a wide-field (+/-~30°of aperture 2.5m refractor telescope to be installed in the International Space Station (ISS. The instrument looks downward from its orbit, into Earth’s atmosphere, with the main objective of observing ultra-violet (UV fluorescence light generated by Ultra-High Energy Cosmic Rays (UHECR extensive air showers (EAS. It is a frontier particle-physics experiment, the first of its kind. The validation of the technical readiness level of such a complex and unique instrument requires prototypes at several levels of integration. At the highest level, the EUSO-Balloon instrument has been conceived, through French space agency (CNES. At a smaller scale and in suborbital flight, EUSO-Balloon integrates all the sub-systems of the full space JEM-EUSO telescope, allowing end-to-end testing of hardware and interfaces, and to probing the global detection chain and strategy, while improving at the same time our knowledge of atmospheric and terrestrial UV background. EUSO-Balloon will be flown by CNES for the first time from Timmins, Canada; on spring 2014.This article presents the low-voltage power supply (LVPS subsystem development for the EUSO-Balloon instrument. This LVPS is the fully operational prototype for the space instrument JEM-EUSO. Besides design and construction, all performance tests and integration results with the other involved subsystems are shown.

  17. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  18. Application of Low Voltage High Resistance Grounding in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Choong-Koo Chang

    2016-02-01

    Full Text Available Most nuclear power plants now utilize solid grounded low voltage systems. For safety and reliability reasons, the low voltage (LV high resistance grounding (HRG system is also increasingly used in the pulp and paper, petroleum and chemical, and semiconductor industries. Fault detection is easiest and fastest with a solidly grounded system. However, a solidly grounded system has many limitations such as severe fault damage, poor reliability on essential circuits, and electrical noise caused by the high magnitude of ground fault currents. This paper will briefly address the strengths and weaknesses of LV grounding systems. An example of a low voltage HRG system in the LV system of a nuclear power plant will be presented. The HRG system is highly recommended for LV systems of nuclear power plants if sufficient considerations are provided to prevent nuisance tripping of ground fault relays and to avoid the deterioration of system reliability.

  19. The degradation diagnosis of low voltage cables used at nuclear power plants

    International Nuclear Information System (INIS)

    Yamamoto, Toshio; Ashida, Tetsuya; Ikeda, Takeshi; Yasuhara, Takeshi; Takechi, Kei; Araki, Shogo

    2001-01-01

    Low voltage cables which have been used for the supply of electric power and the propagation of control signals in nuclear power plants must be sound for safe and stable operation. The long use of nuclear power plants has been reviewed, and the degradation diagnosis to estimate the soundness of low voltage cables has been emphasized. Mitsubishi Cable Industries has established a degradation diagnosis method of cables which convert the velocity of ultrasonic wave in the surface layer of the cable insulation or jacket into breaking elongation, and has developed a degradation diagnosis equipment of low voltage cables used at nuclear power plants in cooperation with Mitsubishi Heavy Industries. This equipment can be moved by an ultrasonic probe by sequential control and measure the ultrasonic velocity automatically. It is capable of a fast an sensitive diagnosis of the cables. We report the outline of this degradation diagnosis equipment and an example of the adaptability estimation at an actual nuclear power plant. (author)

  20. Output Force Enhancement of Scratch Drive Actuator in Low-Voltage Region by Using Flexible Joint

    Directory of Open Access Journals (Sweden)

    Shawn CHEN

    2010-04-01

    Full Text Available Here a low-voltage scratch drive actuator (LVSDA is proposed by incorporating flexible joint into the conventional SDA to improve performance in low-voltage region. Experimental results show that, at the same total plate length of 80 mm and width of 65 mm, the proposed LVSDA can be actuated as low as 40 V, much lower than 80 V, the minimum required input voltage of the conventional SDA. From finite element analysis by CosmosWorks, yielding effect is found to be a critical factor. Before yielding, LVSDA can provide better performance than SDA at the same input voltage. However, the yielding stress in flexible joint would limit the achievable maximum output force in high-voltage region. By varying joint length, width, or location, LVSDA is shown to be operated in low-voltage region where the conventional SDA can not be operated, and can still provide comparable performance as SDA in high-voltage region.

  1. Asymmetrical Grid Fault Ride-Through Strategy of Three-phase Grid-connected Inverter Considering Network Impedance Impact in Low Voltage Grid

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Zhang, Xue; Wang, Baocheng

    2014-01-01

    This letter presents a new control strategy of threephase grid-connected inverter for the positive sequence voltage recovery and negative sequence voltage reduction under asymmetrical grid faults. Unlike the conventional control strategy based on an assumption that the network impedance is mainly...... of the proposed solution for the flexible voltage support in a low-voltage grid, where thenetwork impedance is mainly resistive.......This letter presents a new control strategy of threephase grid-connected inverter for the positive sequence voltage recovery and negative sequence voltage reduction under asymmetrical grid faults. Unlike the conventional control strategy based on an assumption that the network impedance is mainly...... inductive, the proposed control strategy is more flexible and effective by considering the network impedance impact, which is of great importance for the high penetration of grid-connected renewable energy systems into low-voltage grids. The experimental tests are carried out to validate the effectiveness...

  2. Demand Response in Low Voltage Distribution Networks with High PV Penetration

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    the required flexibility from the electricity market through an aggregator. The optimum demand response enables consumption of maximum renewable energy within the network constraints. Simulation studies are conducted using Matlab and DigSilent Power factory software on a Danish low-voltage distribution system......In this paper, application of demand response to accommodate maximum PV power in a low-voltage distribution network is discussed. A centralized control based on model predictive control method is proposed for the computation of optimal demand response on an hourly basis. The proposed method uses PV...

  3. Safety Training: "Habilitation électrique - Electrician Low Voltage - Initial" course in October

    CERN Multimedia

    Safety Training, HSE Unit

    2016-01-01

    The next session of the course "Habilitation électrique - Electrician Low Voltage - Initial" will be given, in French, from 03 to 05 October 2016.   This course is designed for anyone required to safely perform operations on electrical installations and equipment at low voltage to comply with the requirements of the NF C 18 510 standard. Grade of authorisation: B1-B1V-B2-B2V-BR-BC. There are places available. If you are interested in following this course, please fill in your EDH training request via our classroom course catalogue CTA.  

  4. Low voltage control for the liquid argon hadronic end-cap calorimeter of ATLAS

    CERN Document Server

    Brettel, H; Habring, J; Oberlack, H; Schacht, P

    2002-01-01

    At the ATLAS detector a SCADA system surveys and controls the sub- detectors. The link is realized by PVSS2 software and a CanBus hardware system. The low voltages for the Hadronic Endcaps of the liquid argon calorimeter are produced by DC/DC-converters in the power boxes and split into 320 channels corresponding to the pre- amplifier and summing boards in the cryostat. Six units of a prototype distribution board are currently under test. Each of it contains 2 ELMBs as CanBus interface, a FPGA of type QL3012 for digital control and 30 low voltage regulators for the individual fine adjustments of the outputs.

  5. ANALYSIS OF GRID-CONNECTED PHOTOVOLTAIC SYSTEM INTEGRATON ON LOW-VOLTAGE DISTRIBUTION NETWORK

    Directory of Open Access Journals (Sweden)

    NEMES C.

    2016-03-01

    Full Text Available The introduction of new local sources on the distribution network will impact the quality of power in different ways. The low-voltage customers are strongly affected by the level of power quality, especially by harmonic distortions. In present paper, the impact on the power quality of a low-voltage utility network with an integrated PV system has been assessed at the point of common coupling of the PV system. In this order, the most representative power quality indices concerning the harmonic distortion have been monitored and compared with the limits set by the corresponding standards.

  6. Introduction of cooperating conductive components into the phosphor to improve the low voltage cathodoluminescence

    International Nuclear Information System (INIS)

    Shang, Chun Yu; Kang, Hui; Jiang, Hong Bo; Bu, Shu Po; Shang, Xiao Hong; Wu, Yan

    2013-01-01

    In order to improve the electric conductivity of Y 2 O 3 :Eu 3+ phosphor with the least amount of conductive component so as to maximize the improvement in low voltage cathodoluminescence, In 2 O 3 and Cu nanowires (NWs) were simultaneously introduced to form Cu NWs/In 2 O 3 -attached Y 2 O 3 :Eu 3+ phosphor. In 2 O 3 and Cu NWs play different roles in the formation of electrically conductive network, i.e., Cu NWs are suitable as conductive channels for charge transmission due to their one-dimensional morphology with large slenderness ratios, while the island-like In 2 O 3 condensates form local conductive contacts joining the adjacent Cu NWs. Meanwhile, In 2 O 3 forms attachment between Cu NWs and the phosphor. Owing to the cooperating effects between Cu NWs/In 2 O 3 conductive components in the phosphor, the efficiency in low voltage cathodoluminescence was significantly improved. -- Highlights: ► In 2 O 3 /Cu NWs were introduced in Y 2 O 3 :Eu 3+ phosphor to improve the low voltage cathodoluminescence. ► In 2 O 3 /Cu NWs play different key roles in the formation of electrically conductive network. ► The cooperating effect was proved by comparing the experimental data and the calculated results. ► The low voltage cathodoluminescence was significantly improved

  7. Real time diagnostic for operation at a CW low voltage FEL

    Energy Technology Data Exchange (ETDEWEB)

    Balfour, C.; Shaw, A.; Mayhew, S.E. [and others

    1995-12-31

    At Liverpool University, a system for single user control of an FEL has been designed to satisfy the low voltage FEL (ie 200kV) operational requirements. This system incorporates many aspects of computer automation for beam diagnostics, radiation detection and vacuum system management. In this paper the results of the development of safety critical control systems critical control systems are reported.

  8. Grid modeling, analysis and simulation of different scenarios for a smart low-voltage distribution grid

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Han, Xue; Bindner, Henrik W.

    2013-01-01

    , the number of cabinets and customers and the load per customer. The aim of the model is to design, implement and test the proposed configuration and to investigate whether the low-voltage distribution grid is prepared for the expected future increase of PV penetration, heat pumps and electric cars. The model...

  9. Power quality issues into a Danish low-voltage grid with electric vehicles

    DEFF Research Database (Denmark)

    Marra, Francesco; Jensen, Morten M.; Garcia-Valle, Rodrigo

    2011-01-01

    An increased interest on electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs) is dealing with their introduction into low voltage (LV) distribution grids. Lately, analysis on power quality issues has received attention when considering EVs as additional load. The charging of EVs...

  10. Electric vehicles integration within low voltage electricity networks & possibilities for distribution energy loss reduction

    NARCIS (Netherlands)

    Lampropoulos, I.; Veldman, E.; Kling, W.L.; Gibescu, M.; Slootweg, J.G.

    2010-01-01

    With the prospect of an increasing number of electric vehicles (EVs) on the road, domestic charging will be the most obvious way to recharge the vehicles’ batteries. However, this can have adverse impacts to low voltage (LV) distribution grids such as high current demand, increased 3-phase load

  11. Control of a battery energy storage system connected to a low voltage grid

    NARCIS (Netherlands)

    van Dun, J.J.C.M.; de Groot, Robert; Morren, Johan; Slootweg, Han

    2015-01-01

    This paper describes the development of a control algorithm for a battery energy storage system, which is connected to a residential low voltage grid. By predicting future load demand and photovoltaic production within the neighbourhood concerned, flattening of the aggregated neighbourhood

  12. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...

  13. Input-current-shaper based on a modified SEPIC converter with low voltage stress

    DEFF Research Database (Denmark)

    Petersen, Lars

    2001-01-01

    The boost topology is often the designer's first choice when dealing with PFC front-ends. This topology is well documented in the literature and has obvious advantages like continuous input current and low voltage- and current-stress compared to other PFC topologies. The PFC SEPIC converter also...

  14. Humidity Steady State Low Voltage Testing of MLCCs (Based on NESC Technical Assessment Report)

    Science.gov (United States)

    Sampson, Mike; Brusse, Jay; Teverovsky, Alexander

    2011-01-01

    Review of the low voltage reduced Insulation Resistance (IR) failure phenomenon in Multilayer ceramic capacitors (MLCCs)and NASA approaches to contend with this risk. 1. Analyze published materials on root cause mechanisms. 2. Investigate suitability of current test methods to assess MLCC lots for susceptibility. 3. Review current NASA parts selection and application guidelines in consideration of benefits vs. disadvantages.

  15. Admissibility of building cost subsidy in the power grid above the low voltage level

    International Nuclear Information System (INIS)

    Foerster, Sven

    2015-01-01

    Electricity networks are essential to the provision of electrical power to businesses and individuals. In particular for manufacturing businesses a connection to the grid above the low-voltage level is often useful. Network operators demand a subsidy for the new connection and for the change to a higher network level under the auspices of construction cost. The power network market above the low-voltage level is a natural monopoly. This leaves consumers looking for a connection to the power grid with no possibility to select among different network operators. Construction cost subsidies are not regulated by law above the low voltage level. The lack of legal regulation and the natural monopoly above the low-voltage level affect the balance of power between network operators and system users. The lawfulness of the construction cost subsidies, the prerequisites for their demand and a review of the calculation models (Leistungspreismodell, 2-Ebenen-Modell) as well as a proposal for a reform of this system form the subject of this work.

  16. Low voltage driven dielectric electro active polymer actuator with integrated piezoelectric transformer based driver

    DEFF Research Database (Denmark)

    Andersen, Thomas; Rødgaard, Martin Schøler; Thomsen, Ole Cornelius

    2011-01-01

    actuators, a low voltage solution is developed by integrating the driver electronic into a 110 mm tall cylindrical coreless Push InLastor actuator. To decrease the size of the driver, a piezoelectric transformer (PT) based solution is utilized. The PT is essentially an improved Rosen type PT...

  17. Multi-objective optimization control of plug-in electric vehicles in low voltage distribution networks

    DEFF Research Database (Denmark)

    García-Villalobos, J.; Zamora, I.; Knezovic, Katarina

    2016-01-01

    The massive introduction of plug-in electric vehicles (PEVs) into low voltage (LV) distribution networks will lead to several problems, such as: increase of energy losses, decrease of distribution transformer lifetime, lines and transformer overload issues, voltage drops and unbalances...

  18. Low voltage electroosmotic pump for high density integration into microfabricated fluidic systems

    NARCIS (Netherlands)

    Heuck, F.C.A.; Staufer, U.

    2011-01-01

    A low voltage electroosmotic (eo) pump suitable for high density integration into microfabricated fluidic systems has been developed. The high density integration of the eo pump required a small footprint as well as a specific on-chip design to ventilate the electrolyzed gases emerging at the

  19. A structured approach to increase situational awareness in low voltage distribution grids

    NARCIS (Netherlands)

    Helmholt, K.A.; Groote Schaarsberg, M.; Broersma, T.; Morren, J.; Kruizinga, B.; Wouters, P.A.A.F.; Steennis, E.F.; Baldinger, F.

    2015-01-01

    Wear and tear, electrification and aging of (low voltage) distribution grids require maintenance in order to assure continuous provision of electricity. Situational awareness is required to find out when parts of the grid need maintenance and which parts should be prioritized. The paper proposes a

  20. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    of incorporating electric vehicles (EVs) in a low voltage distribution network with high penetration of photovoltaic installations (PVs), and focuses on analysing potential voltage support functions from EVs and PVs. In addition, the paper evaluates the benefits that reactive power control may provide...

  1. The fabrication of 3-D nanostructures by a low- voltage EBL

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Seung Hun [Department of Nano Science and Technology, Pusan National University (Korea, Republic of); Kim, Jae Gu [Department of Nano-Mechanical Systems, Korea Institute of Machinery and Materials (Korea, Republic of); Kim, Chang Seok [Department of Cogno-Mechatronics Engineering, Pusan National University (Korea, Republic of); Choi, Doo Sun; Chang, Sunghwan [Department of Nano-Mechanical Systems, Korea Institute of Machinery and Materials (Korea, Republic of); Jeong, Myung Yung, E-mail: myjeong@pusan.ac.kr [Department of Cogno-Mechatronics Engineering, Pusan National University (Korea, Republic of)

    2011-02-15

    Three-dimensional (3-D) structures are used in many applications, including the fabrication of opto-electronic and bio-MEMS devices. Among the various fabrication techniques available for 3-D structures, nano imprint lithography (NIL) is preferred for producing nanoscale 3-D patterns because of its simplicity, relatively short processing time, and high manufacturing precision. For efficient replication in NIL, a precise 3-D stamp must be used as an imprinting tool. Hence, we attempted the fabrication of original 3-D master molds by low-voltage electron beam lithography (EBL). We then fabricated polydimethylsiloxane (PDMS) stamps from the original 3-D mold via replica molding with ultrasonic vibration.First, we experimentally analyzed the characteristics of low-voltage EBL in terms of various parameters such as resist thickness, acceleration voltage, aperture size, and baking temperature. From these e-beam exposure experiments, we found that the exposure depth and width were almost saturated at 3 kV or lesser, even when the electron dosage was increased. This allowed for the fabrication of various stepped 3-D nanostructures at a low voltage. In addition, by using line-dose EBL, V-groove patterns could be fabricated on a cured electron resist (ER) at a low voltage and low baking temperature. Finally, the depth variation could be controlled to within 10 nm through superposition exposure at 1 kV. From these results, we determined the optimum electron beam exposure conditions for the fabrication of various 3-D structures on ERs by low-voltage EBL. We then fabricated PDMS stamps via the replica molding process.

  2. Abstract behaviour modelling and prognosis on the basis of spatially distributed sensor networks with Kohonen cards and Markov chains; Abstrakte Verhaltensmodellierung und -prognose auf der Basis raeumlich verteilter Sensornetze mit Kohonen-Karten und Markov-Ketten

    Energy Technology Data Exchange (ETDEWEB)

    Matthes, J.; Keller, H.B.; Mikut, R. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Angewandte Informatik

    2000-10-01

    Evironmental processes, e.g. local air quality changes in urban agglomerations, buildings and production halls are dynamic processes with regionally distributed physical variables. They can be monitored by networks of distributed measuring probes. Processes of this type form the basis of complex systems with many degrees of freedom and stochastic effects that are difficult to measure. The contribution presents an introduction to Markov chains, proposes a method of generating Markov chains as a prognostic model, and demonstrates the method using the example of an air quality monitoring process. [German] Fuer die Ueberwachung dynamischer Prozesse, deren physikalische Groessen raeumlich verteilt auftreten, werden oft Netze raeumlich verteilter Sensoren eingesetzt. Umweltprozesse, wie z.B. die oertliche Luftqualitaetsaenderung in Ballungsraeumen, Gebaeuden und Produktionsanlagen, aber auch verschiedene verfahrenstechnische Prozesse sind Vertreter dieser Prozessklasse. Solchen Prozessen hinterliegen komplexe Systeme, die durch eine hohe Anzahl an Freiheitsgraden und durch stochastische schwer messbare Einfluesse gekennzeichnet sind. Ziel dieses Vortrages ist es, - eine kurze Einfuehrung zu Markov-Ketten zu gegeben (Abschnitt 2); - ein datengestuetztes Verfahren vorzuschlagen, das nach einer Schaetzung abstrakter Prozesszustaende mit Hilfe von Kohonen-Karten Markov-Ketten als Prognosemodell generiert (Abschnitt 3), und - dieses Verfahren anhand eines Simulationsbeispiels zur Luftqualitaetsueberwachung zu demonstrieren (Abschnitt 4). (orig.)

  3. 30 CFR 77.906 - Trailing cables supplying power to low-voltage mobile equipment; ground wires and ground check...

    Science.gov (United States)

    2010-07-01

    ... portable or mobile equipment from low-voltage three-phase resistance grounded power systems shall contain... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables supplying power to low-voltage... STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage...

  4. Evaluation of diagnostic technique for degradation of low-voltage electric cables with silicone rubber insulator

    International Nuclear Information System (INIS)

    Mikami, Masao

    2005-01-01

    As a part of countermeasures against ageing problems of nuclear power plants, it is requested to establish non-destructive diagnostic technique for their degradation of low voltage electric cables and assessment standard of their life. Having aimed at investigating the degradation of low-voltage electric cable with silicone rubber insulator, change of its surface hardness at elevated temperature were measured by indenter modules. Moreover, we also measured the elongation at break, which is regarded as general degradation index of electric cables, and the surface hardness with a micro hardness meter. Consequently, it is seen that the indenter modulus measurement is (1) capable to obtain general feature of the thermal degradation of silicone rubber insulator, (2) applicable to diagnose the degree of degradation of the electric cable by converting the result to elongation at break, (3) well correlated with the hardness measurement of the electric cable with the micro hardness meter. (author)

  5. Technical Training Seminar: Low-Voltage Differential Signaling (LVDS): Technology and Applications

    CERN Multimedia

    Monique Duval

    2004-01-01

    Tuesday 26 October TECHNICAL TRAINING SEMINAR from 14:00 to 16:30, Auditorium 40-SS-C01 Low-Voltage Differential Signaling (LVDS): Technology and Applications Herbert Eisenring, Kai Peters / NATIONAL SEMICONDUCTOR (Europe) National Semiconductor pioneered the Low-Voltage Differential Signaling (LVDS) technology, and is a recognized leader in high speed differential products and design tools. National Semiconductor offers a wide range of innovative, affordable interconnect solutions including serializer-deserializers (SerDes), drivers-receivers-transceivers, crosspoint switches and clock drivers. LVDS is a new technology addressing the needs of todays high performance data transmission applications, and the LVDS standard is becoming the most popular differential data transmission standard in the industry. This Technical Training Seminar will present National Semiconductor existing and future products, and some applications relevant to the activities carried out at CERN. 14:00 - 14:15 Presentation of Nati...

  6. Technical Training Seminar: Low-Voltage Differential Signaling (LVDS): Technology and Applications

    CERN Multimedia

    Monique Duval

    2004-01-01

    Tuesday 26 October TECHNICAL TRAINING SEMINAR from 14:00 to 16:30, Auditorium 40-SS-C01 Low-Voltage Differential Signaling (LVDS): Technology and Applications Herbert Eisenring, Kai Peters / NATIONAL SEMICONDUCTOR (Europe) National Semiconductor pioneered the Low-Voltage Differential Signaling (LVDS) technology, and is a recognized leader in high speed differential products and design tools. National Semiconductor offers a wide range of innovative, affordable interconnect solutions including serializer-deserializers (SerDes), drivers-receivers-transceivers, crosspoint switches and clock drivers. LVDS is a new technology addressing the needs of todays high performance data transmission applications, and the LVDS standard is becoming the most popular differential data transmission standard in the industry. This Technical Training Seminar will present National Semiconductor existing and future products, and some applications relevant to the activities carried out at CERN. 14:00 - 14:15 Presentation of Nat...

  7. Flexible Demand Control to Enhance the Dynamic Operation of Low Voltage Networks

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Szczesny, Ireneusz Grzegorz; Pillai, Jayakrishnan Radhakrishna

    2015-01-01

    Moving towards a carbon free energy system has become an objective for many countries nowadays. Among other changes, the electrification of strategic sectors such as heating and transportation is inevitable. As a consequence, the current power system load will substantially increase...... for controlling the demand response of a low voltage grid. This is designed to; i) maximize the grid utilization, thereby reducing the need for reinforcement, ii) accommodate the maximum number of flexible loads and iii) satisfy the power and comfort requirements from each of the consumers in the network....... In this context, the nature of the expected loads (heat pumps, plug-in electric vehicles, etc.) makes the low voltage networks specially targeted. A promising solution to overcome the challenges resulting from their grid integration, is demand response. This paper introduces a hierarchical structure...

  8. A Decentralized Multi-Agent-Based Approach for Low Voltage Microgrid Restoration

    Directory of Open Access Journals (Sweden)

    Ebrahim Rokrok

    2017-09-01

    Full Text Available Although a well-organized power system is less subject to blackouts, the existence of a proper restoration plan is nevertheless still essential. The goal of a restoration plan is to bring the power system back to its normal operating conditions in the shortest time after a blackout occurs and to minimize the impact of the blackout on society. This paper presents a decentralized multi-agent system (MAS-based restoration method for a low voltage (LV microgrid (MG. In the proposed method, the MG local controllers are assigned to the specific agents who interact with each other to achieve a common decision in the restoration procedure. The evaluation of the proposed decentralized technique using a benchmark low-voltage MG network demonstrates the effectiveness of the proposed restoration plan.

  9. Restoration of Low-Voltage Distribution Systems with Inverter-Interfaced DG Units

    DEFF Research Database (Denmark)

    Dietmannsberger, Markus; Wang, Xiongfei; Blaabjerg, Frede

    2018-01-01

    -area voltage collapse. This paper proposes a restoration strategy from zero voltage conditions for inverter-interfaced DG under islanded conditions. In the approach, a flexible and scalable Master DG inverter concept is introduced for distributed generations, where no communication is needed and an outage......The increasing share of distributed generation (DG) offers new chances in grid restoration of low-voltage distribution grids. Instead of relying on the transmission or high- and medium-voltage levels, establishing islanding operation in low-voltage grids might be a good option after a wide...... of the Master can be balanced by other DG inverters. The control strategy ensures the tracking of nominal values of the system voltage and frequency without zero steady-state error. The influences of non-controllable DG are also taken into account in the strategy with an effective countermeasure developed...

  10. Antenna Characterization for the JOLT Impulsive Radiator via Low-Voltage Measurements

    Science.gov (United States)

    Tyo, J. S.; Schoenberg, J. S. H.; Baum, C. E.; Prather, W. D.; Hackett, R.; Burger, J. W.; Farr, E. G.; Giri, D. V.; McLemore, D. P.

    The JOLT system is a highly directive, impulse-like radiator. The antenna for JOLT is a 10-ft-diameter half-impulse radiating antenna (HIRA). JOLT was one of the first impulse radiating systems to employ a half IRA. For that reason, extensive measurements were made with a prototype, scale model HIRA in order to understand the performance of this class of antenna. In addition, a series of low-voltage antenna subsystem tests were performed with the full JOLT antenna before it was couple to the pulsed power and run at high voltage. The low-voltage measurements proved to be quite valuable, as an important manufacturing defect—a failure to mount the dish perpendicular to the ground plane—was identified and mitigated.

  11. Assessing the use of Low Voltage UV-light Emitting Miniature LEDs for Marine Biofouling Control

    Science.gov (United States)

    2016-07-01

    of that required to drive traditional UV mercury lamps . Secondly, given their small size and relatively low cost, UV LEDs provide ease of maintenance...UNCLASSIFIED UNCLASSIFIED Assessing the use of Low Voltage UV -light Emitting Miniature LEDs for Marine Biofouling Control Richard...settling organisms. The introduction of miniature UV light emitting diodes ( LEDs ) as a light source enables them to be embedded into thin, flexible

  12. Theory of the low-voltage impedance of superconductor-- p insulator--normal metal tunnel junctions

    International Nuclear Information System (INIS)

    Lemberger, T.R.

    1984-01-01

    A theory for the low-voltage impedance of a superconductor-- p insulator--normal metal tunnel junction is developed that includes the effects of charge imbalance and of quasiparticle fluctuations. A novel, inelastic, charge-imbalance relaxation process is identified that is associated with the junction itself. This new process leads to the surprising result that the charge-imbalance component of the dc resistance of a junction becomes independent of the electron-phonon scattering rate as the insulator resistance decreases

  13. A low voltage programmable unipolar inverter with a gold nanoparticle monolayer on plastic.

    Science.gov (United States)

    Zhou, Ye; Han, Su-Ting; Huang, Long-Biao; Huang, Jing; Yan, Yan; Zhou, Li; Roy, V A L

    2013-05-24

    A programmable low voltage unipolar inverter with saturated-load configuration has been demonstrated on a plastic substrate. A self-assembled monolayer of gold (Au) nanoparticles was inserted into the dielectric layer acting as a charge trapping layer. The inverter operated well with supply voltages of inverter. Furthermore, the programmable behavior was maintained well at various bending states, demonstrating the adequate flexibility of our devices.

  14. Investigation of Electron Beam Induced Mass Loss of Embedding Media in the Low Voltage STEM

    Czech Academy of Sciences Publication Activity Database

    Novotná, V.; Hrubanová, Kamila; Nebesářová, J.; Krzyžánek, Vladislav

    2014-01-01

    Roč. 20, S3 (2014), s. 1270-1271 ISSN 1431-9276 R&D Projects: GA MŠk EE.2.3.20.0103; GA MŠk(CZ) LO1212; GA ČR(CZ) GA14-20012S; GA TA ČR TE01020118 Institutional support: RVO:68081731 Keywords : mass loss * mass -thickness measurement * low voltage STEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.877, year: 2014

  15. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  16. The European Foundation for Quality Management (EFQM Excellence Model in a Low Voltage Switchgear Compan

    Directory of Open Access Journals (Sweden)

    Özgür Özmen

    2017-11-01

    Full Text Available The Turkish low voltage switchgear sector is made up of several local and international companies. Generally, local companies operating in this sector try to get a competitive advantage by fabricating cheap products, in order to cope with the competition that focuses more on quality. What’s more, international corporations perform quality activities under the organization and control of their top-managements from abroad. Although VIKO is a local producer, it is a company willing to invest more in quality, as well as in research and development. VIKO company is the focus of this self-assessment study, since it lies at the conjunction of companies operating in this sector, it being a local company performing various quality enhancement activities. Simultaneously, the authors consider that this study shall prove useful to create an overview over the entire Turkish low voltage switchgear sector. The evaluation of the company and its core-activities was based upon nine criteria of the European Foundation for Quality Management (EFQM Excellence Model, in order to identify the strengths, the weaknesses and aspects that require improvements. This is the first study worldwide performed in the low voltage switchgear sector and it is aimed at motivating other Turkish companies that operate in this sector to implement The European Foundation for Quality Management (EFQM Excellence Model in their TQM activities (Total Quality Management.

  17. Efficient Low-Voltage Operation of a CW Gyrotron Oscillator at 233 GHz.

    Science.gov (United States)

    Hornstein, Melissa K; Bajaj, Vikram S; Griffin, Robert G; Temkin, Richard J

    2007-02-01

    The gyrotron oscillator is a source of high average power millimeter-wave through terahertz radiation. In this paper, we report low beam power and high-efficiency operation of a tunable gyrotron oscillator at 233 GHz. The low-voltage operating mode provides a path to further miniaturization of the gyrotron through reduction in the size of the electron gun, power supply, collector, and cooling system, which will benefit industrial and scientific applications requiring portability. Detailed studies of low-voltage operation in the TE(2) (,) (3) (,) (1) mode reveal that the mode can be excited with less than 7 W of beam power at 3.5 kV. During CW operation with 3.5-kV beam voltage and 50-mA beam current, the gyrotron generates 12 W of RF power at 233.2 GHz. The EGUN electron optics code describes the low-voltage operation of the electron gun. Using gun-operating parameters derived from EGUN simulations, we show that a linear theory adequately predicts the low experimental starting currents.

  18. A high-efficiency low-voltage CMOS rectifier for harvesting energy in implantable devices.

    Science.gov (United States)

    Hashemi, S Saeid; Sawan, Mohamad; Savaria, Yvon

    2012-08-01

    We present, in this paper, a new full-wave CMOS rectifier dedicated for wirelessly-powered low-voltage biomedical implants. It uses bootstrapped capacitors to reduce the effective threshold voltage of selected MOS switches. It achieves a significant increase in its overall power efficiency and low voltage-drop. Therefore, the rectifier is good for applications with low-voltage power supplies and large load current. The rectifier topology does not require complex circuit design. The highest voltages available in the circuit are used to drive the gates of selected transistors in order to reduce leakage current and to lower their channel on-resistance, while having high transconductance. The proposed rectifier was fabricated using the standard TSMC 0.18 μm CMOS process. When connected to a sinusoidal source of 3.3 V peak amplitude, it allows improving the overall power efficiency by 11% compared to the best recently published results given by a gate cross-coupled-based structure.

  19. The Simulation Study of a Restructured Residential Low-Voltage Distribution System Microgrid

    Directory of Open Access Journals (Sweden)

    L. Ramesh

    2016-12-01

    Full Text Available A primary and necessary focus in creating a greener environment is the conversion of existing power-generation sources to renewable power sources in the near future. Another important focus is to develop sustainable household power generation to a low-voltage electricity grid with a power purchase and selling facility. To help with achieving the above vision, the objective of this work is to critically analyze the existing low-voltage distribution system and make suggestions for restructuring it to the low-voltage interconnected microgrid (MG. The test was carried out in the Tamil Nadu Electricity Board (TNEB 100kVA transformer feeder which was connected to supply around 100 houses with electricity. The performance analysis of the proposed system was examined through different case studies, represented as a normal operating condition of the existing distribution system and a reconstructed and interconnected MG to the TNEB grid. The project was designed and analyzed using PSCAD software. The results discussed in the project are helpful in examining the effects of multiple distributed energy resources on distributed generation. In future, knowledge of these effects may be helpful for rural area electrification.

  20. Digital control systems. Verteilte Prozessleitsysteme

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    With a distinct description of the systems properties thin regulation shall provide a latter transparency for the use of digital control systems. The application of the new technique shall be facilitated, incitations for the further development shall be given and the compatibility of the systems shall be advanced. Moreover, the regulation can be used as criteria catalogue for the evaluation of digital systems.

  1. Frequency pulling in a low-voltage medium-power gyrotron

    Science.gov (United States)

    Luo, Li; Du, Chao-Hai; Huang, Ming-Guang; Liu, Pu-Kun

    2018-04-01

    Many recent biomedical applications use medium-power frequency-tunable terahertz (THz) sources, such as sensitivity-enhanced nuclear magnetic resonance, THz imaging, and biomedical treatment. As a promising candidate, a low-voltage gyrotron can generate watt-level, continuous THz-wave radiation. In particular, the frequency-pulling effect in a gyrotron, namely, the effect of the electron beam parameters on the oscillation frequency, can be used to tune the operating frequency. Most previous investigations used complicated and time-consuming gyrotron nonlinear theory to study the influence of many beam parameters on the interaction performance. While gyrotron linear theory investigation demonstrates the advantages of rapidly and clearly revealing the physical influence of individual key beam parameters on the overall system performance, this paper demonstrates systematically the use of gyrotron linear theory to study the frequency-pulling effect in a low-voltage gyrotron with either a Gaussian or a sinusoidal axial-field profile. Furthermore, simulations of a gyrotron operating in the first axial mode are carried out in the framework of nonlinear theory as a contrast. Close agreement is achieved between the two theories. Besides, some interesting results are obtained. In a low-current sinusoidal-profile cavity, the ranges of frequency variation for different axial modes are isolated from each other, and the frequency tuning bandwidth for each axial mode increases by increasing either the beam voltage or pitch factor. Lowering the voltage, the total tuning ranges are squeezed and become concentrated. However, the isolated frequency regions of each axial mode cannot be linked up unless the beam current is increased, meaning that higher current operation is the key to achieving a wider and continuous tuning frequency range. The results presented in this paper can provide a reference for designing a broadband low-voltage gyrotron.

  2. Calibration of Monte Carlo simulation code to low voltage electron beams through radiachromic dosimetry

    International Nuclear Information System (INIS)

    Weiss, D.E.; Kalweit, H.W.; Kensek, R.P.

    1994-01-01

    A simple multilayer slab model of an electron beam using the ITS/TIGER code can consistently account for about 80% of the actual dose delivered by a low voltage electron beam. The difference in calculated values is principally due to the 3D hibachi structure which blocks 22% of the beam. A 3D model was constructed using the ITS/ACCEPT code to improve upon the TIGER simulations. A rectangular source description update to the code and reproduction of all key geometric elements involved, including the hibachi, accounted for 90-95% of the dose received by routine dosimetry

  3. Collapse of a cavitation bubble generated by low voltage discharge in water

    Directory of Open Access Journals (Sweden)

    Zima Patrik

    2012-04-01

    Full Text Available The article presents experimental results of the optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of two low-voltage capacitors. High-speed CCD camera was used to record the time evolution of the bubble size. High-power halogen lamp was used for illumination. The system was synchronized by pulse generator connected to an oscilloscope. The velocity of the re-entrant jet was estimated from the time resolved photography for different maximum bubble sizes.

  4. Integration of Fuel Cell Micro-CHPs on Low. Voltage Grid: A Danish Case Study

    DEFF Research Database (Denmark)

    You, Shi; Marra, Francesco; Træholt, Chresten

    2012-01-01

    The future significance of fuel cell (FC) powered micro combined heat and power (micro-CHP) units in meeting the residential energy demands is set to increase, which may have a considerable impact on the low voltage (LV) grid. The objective of this paper is to investigate into the related technical...... issues using a Danish case study with different penetration levels of uncoordinated FC micro-CHPs. Based on the findings, it is recommended to design grid oriented integration strategies such as Virtual Power Plants (VPPs) for achieving future smart grids with a large roll out of distributed energy...

  5. Low voltage excess noise and shot noise in YBCO bicrystal junctions

    DEFF Research Database (Denmark)

    Constantinian, K.Y.; Ovsyannikov, G.A.; Borisenko, I.V.

    2002-01-01

    The spectral density of background noise emitted by symmetric bicrystal YBaCuO Josephson junctions on sapphire substrates have been measured by a low noise cooled HEMT amplifier for bias voltages up to V approximate to 50 mV. At relatively low voltages V noise rise has been...... registered. At large bias voltages V > 30 mV a clear dependence of noise power. exactly coinciding to the asymptote of the Schottky shot noise function, has been observed for the first time. Experimental results are discussed in terms of multiple Andreev reflections which may take place in d...

  6. Studies on low-voltage x-ray radiography for graphite materials

    International Nuclear Information System (INIS)

    Muraoka, Susumu; Itami, Hiroharu

    1978-09-01

    Low-voltage radiography has been studied to provide optimum technique for graphite less than 50 mm thick. First we determined the exposure conditions under which the most appropriate photographic density can be obtained. By parametric studies, an exposure chart was prepared. Then we studied how the environment of photographing affected the film density. Thirdly, by use of graphite materials with artificial flaws, Image Quality Indicator (I.Q.I.) sensitivity was determined. Detectability of a crack depended on an incidence angle of X-rays onto a crack. Finally, we photographed graphites having natural flaws and gained a useful information. (author)

  7. Effects of low voltage electrolysis and freezing on coliform content of contaminated water

    International Nuclear Information System (INIS)

    Qazi, J.I.; Saleem, F.

    2003-01-01

    A sewage sample was mixed with drinking water and subjected to low voltage (15V) electrolysis in the presence of 1% NaCl. The prepared sample was also kept in freezer with and without the presence of sodium chloride for 4-hours. Among these treatments the electrolysis proved to kill the coliforms, while the freezing reduced the bacterial content. Antibiotics sensitivity patterns revealed that certain of the coliform strains survived the freezing and thawing shocks. Nature of such surviving bacteria and need to study chemical parameters of electrolyzed water are discussed. (author)

  8. Conversion Coatings Produced on AZ61 Magnesium Alloy by Low-Voltage Process

    Directory of Open Access Journals (Sweden)

    Nowak M.

    2016-03-01

    Full Text Available The resultes of anodic oxide conversion coatings on wrought AZ61 magnesium alloy production are describe. The studies were conducted in a solution containing: KOH (80 g/l and KF (300 g/l using anodic current densities of 3, 5 and 10 A/dm2 and different process durations. The obtained coatings were examined under a microscope and corrosion tests were performed by electrochemical method. Based on these results, it was found that the low-voltage process produces coatings conferring improved corrosion resistance to the tested magnesium alloy.

  9. Effects of a low-voltage static electric field on energy metabolism in astrocytes.

    Science.gov (United States)

    Huang, R; Peng, L; Hertz, L

    1997-01-01

    Mouse astrocytes (glial cells) in primary cultures were exposed to a low-voltage static DC electric field with no current flow and thus with no generation of magnetic fields. The electric field altered the rate of glycolysis, measured by 2-deoxyglucose accumulation. The magnitude and direction of this effect depended on the polarization of the field and the applied voltage. The maximum effect was an increase of approximately 30%, which occurred with field across the cells at an intensity that can be calculated to be 0.3 mV/cm or less. Reversal of the polarization converted the stimulation to a small but statistically significant inhibition.

  10. Low-Voltage Ride-Through of Variable Speed Wind Turbines with Permanent Magnet Synchronous Generator

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2009-01-01

    This paper presents a simulation model of a MW-level variable speed wind turbine with a permanent magnet synchronous generator (PMSG) and a full-scale converter developed in the simulation tool of PSCAD/EMTDC. The low voltage ride-through (LVRT) capability of the wind turbine is investigated. A new...... control scheme for the wind turbine that keeps it connected to the grid during grid faults is designed and simulated. Its design has special focus on the regulation of the DC-link voltage. Simulation results show the proposed control scheme is an effective measure to improve LVRT capability of variable...

  11. Optimal Design of DC Fast-Charging Stations for EVs in Low Voltage Grids

    DEFF Research Database (Denmark)

    Gjelaj, Marjan; Træholt, Chresten; Hashemi Toghroljerdi, Seyedmostafa

    2017-01-01

    DC Fast Charging Station (DCFCS) is essential for widespread use of Electric Vehicle (EVs). It can recharge EVs in direct current in a short period of time. In recent years, the increasing penetration of EVs and their charging systems are going through a series of changes. This paper addresses...... on the power grid through the application of electrical storage systems within the DC fast charging stations. The proposed solution decreases the charging time and the impact on the low voltage (LV) grid significantly. The charger can be used as a multifunctional grid-utility such as congestion management...

  12. A novel water resistor divider with a coaxial low-voltage arm.

    Science.gov (United States)

    Jia, Wei; Chen, Weiqing; Mao, Congguang; Zeng, Jiangtao

    2010-03-01

    A new style high voltage resistor divider made of saline solution has been constructed and tested. A coaxial construction is used on the low-voltage arm, as the signal extraction electrode, which can increase the attenuation ratio of the divider. The time response of divider limited by the stray parameter also can be improved. Comparing the results of calibrated experiment with the commonly used equal size copper sulfate dividers, the new probe has nearly five times increase in the attenuation ratio. The time response of the new style divider in the dimension of 30 mm in diameter and 400 mm in length can reach to 1 ns.

  13. Magnetic lens apparatus for a low-voltage high-resolution electron microscope

    Science.gov (United States)

    Crewe, Albert V.

    1996-01-01

    A lens apparatus in which a beam of charged particles of low accelerating voltage is brought to a focus by a magnetic field, the lens being situated behind the target position. The lens comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. The lens apparatus comprises the sole focusing lens for high-resolution imaging in a low-voltage scanning electron microscope.

  14. Integration of 100% Micro-Distributed Energy Resources in the Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    You, Shi; Segerberg, Helena

    2014-01-01

    of heat pumps (HPs) and plug-in electric vehicles (PEVs) at 100% penetration level on a representative urban residential low voltage (LV) distribution network of Denmark are investigated by performing a steady-state load flow analysis through an integrated simulation setup. Three DERs integration...... oriented integration strategies, having 100% integration of DER in the provided LV network is feasible.......The existing electricity infrastructure may to a great extent limit a high penetration of the micro-sized Distributed Energy Resources (DERs), due to the physical bottlenecks, e.g. thermal capacitates of cables, transformers and the voltage limitations. In this study, the integration impacts...

  15. Design Margin Elimination Through Robust Timing Error Detection at Ultra-Low Voltage

    OpenAIRE

    Reyserhove, Hans; Dehaene, Wim

    2017-01-01

    This paper discusses a timing error masking-aware ARM Cortex M0 microcontroller system. Through in-path timing error detection, operation at the point-of-first-failure is possi- ble without corrupting the pipeline state, effectively eliminat- ing traditional timing margins. Error events are flagged and gathered to allow dynamic voltage scaling. The error-aware microcontroller was implemented in a 40nm CMOS process and realizes ultra-low voltage operation down to 0.29V at 5MHz consuming 12.90p...

  16. Separating topographical and chemical analysis of nanostructure of polymer composite in low voltage SEM

    International Nuclear Information System (INIS)

    Wan, Q; Plenderleith, R A; Claeyssens, F; Rodenburg, C; Dapor, M; Rimmer, S

    2015-01-01

    The possibility of separating the topographical and chemical information in a polymer nano-composite using low-voltage SEM imaging is demonstrated, when images are acquired with a Concentric Backscattered (CBS) detector. This separation of chemical and topographical information is based on the different angular distribution of electron scattering which were calculated using a Monte Carlo simulation. The simulation based on angular restricted detection was applied to a semi-branched PNIPAM/PEGDA interpenetration network for which a linear relationship of topography SEM contrast and feature height data was observed. (paper)

  17. Loss of Synchronism of Wind Turbine Converters during Low Voltage Grid Faults

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sørensen, Poul Ejnar; Iov, Florin

    2014-01-01

    In the recent grid codes, wind power plants are required to stay connected and inject reactive and active currents during grid short-circuit faults, even when the grid voltage drops down to zero. However, the physical fact, Loss of Synchronism (LOS) of wind turbines during these very low voltage ...... as whole. Additionally, existing methods to solve the LOS problem are briefly reviewed, and a closed loop frequency based solution is implemented within PowerFactory simulations of a detailed generic wind power plant model....

  18. Surge Protection in Low-Voltage AC Power Circuits: An Anthology

    Science.gov (United States)

    Martzloff, F. D.

    2002-10-01

    The papers included in this part of the Anthology provide basic information on the propagation of surges in low-voltage AC power circuits. The subject was approached by a combination of experiments and theoretical considerations. One important distinction is made between voltage surges and current surges. Historically, voltage surges were the initial concern. After the introduction and widespread use of current-diverting surge-protective devices at the point-of-use, the propagation of current surges became a significant factor. The papers included in this part reflect this dual dichotomy of voltage versus current and impedance mismatch effects versus simple circuit theory.

  19. Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers

    International Nuclear Information System (INIS)

    McBride, J. W.; Balestrero, A.; Tribulato, G.; Ghezzi, L.; Cross, K. J.

    2010-01-01

    An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10 6 images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

  20. Three-phase Power Flow Calculation of Low Voltage Distribution Network Considering Characteristics of Residents Load

    Science.gov (United States)

    Wang, Yaping; Lin, Shunjiang; Yang, Zhibin

    2017-05-01

    In the traditional three-phase power flow calculation of the low voltage distribution network, the load model is described as constant power. Since this model cannot reflect the characteristics of actual loads, the result of the traditional calculation is always different from the actual situation. In this paper, the load model in which dynamic load represented by air conditioners parallel with static load represented by lighting loads is used to describe characteristics of residents load, and the three-phase power flow calculation model is proposed. The power flow calculation model includes the power balance equations of three-phase (A,B,C), the current balance equations of phase 0, and the torque balancing equations of induction motors in air conditioners. And then an alternating iterative algorithm of induction motor torque balance equations with each node balance equations is proposed to solve the three-phase power flow model. This method is applied to an actual low voltage distribution network of residents load, and by the calculation of three different operating states of air conditioners, the result demonstrates the effectiveness of the proposed model and the algorithm.

  1. Coordinated Low Voltage Ride through strategies for Permanent Magnet Direct Drive Synchronous Generators

    Directory of Open Access Journals (Sweden)

    Zhang Ge

    2016-01-01

    Full Text Available By analyzing the mechanism of the low voltage ride through on the permanent magnet direct drive synchronous wind power generating units, this paper proposes a coordinated control strategy for permanent magnet synchronous generator. In order to avoid over speed operation of the generation units, over voltage on DC capacitor and over current on convert, the improved pitch angle control and inverter control are used. When the grid voltage drops, the captured wind power is cut down by the variable pitch system, which limits the speed of the generator, the generator side converter keeps the DC capacitor voltage stabile; and the grid side converter provides reactive power to the grid to help the grid voltage recover. The control strategy does not require any additional hardware equipment, with existing control means, the unit will be able to realize low voltage ride through. Finally, based on Matlab/Simulink to build permanent magnet direct drive wind power generation system, the simulation results verify the correctness and effectiveness of the control strategy.

  2. Statistical Feature Extraction for Fault Locations in Nonintrusive Fault Detection of Low Voltage Distribution Systems

    Directory of Open Access Journals (Sweden)

    Hsueh-Hsien Chang

    2017-04-01

    Full Text Available This paper proposes statistical feature extraction methods combined with artificial intelligence (AI approaches for fault locations in non-intrusive single-line-to-ground fault (SLGF detection of low voltage distribution systems. The input features of the AI algorithms are extracted using statistical moment transformation for reducing the dimensions of the power signature inputs measured by using non-intrusive fault monitoring (NIFM techniques. The data required to develop the network are generated by simulating SLGF using the Electromagnetic Transient Program (EMTP in a test system. To enhance the identification accuracy, these features after normalization are given to AI algorithms for presenting and evaluating in this paper. Different AI techniques are then utilized to compare which identification algorithms are suitable to diagnose the SLGF for various power signatures in a NIFM system. The simulation results show that the proposed method is effective and can identify the fault locations by using non-intrusive monitoring techniques for low voltage distribution systems.

  3. Flexible and low-voltage integrated circuits constructed from high-performance nanocrystal transistors.

    Science.gov (United States)

    Kim, David K; Lai, Yuming; Diroll, Benjamin T; Murray, Christopher B; Kagan, Cherie R

    2012-01-01

    Colloidal semiconductor nanocrystals are emerging as a new class of solution-processable materials for low-cost, flexible, thin-film electronics. Although these colloidal inks have been shown to form single, thin-film field-effect transistors with impressive characteristics, the use of multiple high-performance nanocrystal field-effect transistors in large-area integrated circuits has not been shown. This is needed to understand and demonstrate the applicability of these discrete nanocrystal field-effect transistors for advanced electronic technologies. Here we report solution-deposited nanocrystal integrated circuits, showing nanocrystal integrated circuit inverters, amplifiers and ring oscillators, constructed from high-performance, low-voltage, low-hysteresis CdSe nanocrystal field-effect transistors with electron mobilities of up to 22 cm(2) V(-1) s(-1), current modulation >10(6) and subthreshold swing of 0.28 V dec(-1). We fabricated the nanocrystal field-effect transistors and nanocrystal integrated circuits from colloidal inks on flexible plastic substrates and scaled the devices to operate at low voltages. We demonstrate that colloidal nanocrystal field-effect transistors can be used as building blocks to construct complex integrated circuits, promising a viable material for low-cost, flexible, large-area electronics.

  4. Degradation diagnosing method for low voltage electric wire and cable in nuclear facility

    International Nuclear Information System (INIS)

    Kamimura, Seiji; Seki, Ikuo; Yagyu, Hideki; Onishi, Takao; Kusama, Yasuo.

    1991-01-01

    A considerable skill is required for a visual inspection method which has been used most widely for determining the degradation of low voltage electric wires and cables used mostly in facilities such as nuclear power plants. It is extremely difficult to determine the degradation accurately and appropriately even for skilled inspectors because of individual difference. Then, a small amount of organic insulation materials is taken as a sample from insulators or sheath materials actually disposed. The pyrolytic temperature of the sample is measured by thermal gravimetric analysis to determine the extent of the degradation of the electric wire and cable based on the relationship between the degradation and the elongation. Since there is a close relationship between the temperature at which the measured weight of the sample is reduced by 5% and the degradation behavior of the mechanical property, analysis can be conducted effectively by an extremely small amount of the sample. Since the insulation degradation of relatively low voltage electric wires and cables can be determined in a non-destructive manner at high accuracy, the lifetime can be forecasted. (N.H.)

  5. Proton conducting sodium alginate electrolyte laterally coupled low-voltage oxide-based transistors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang Hui; Wan, Qing, E-mail: wanqing@nju.edu.cn [Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); School of Electronic Science and Engineering, Nanjing University, Nanjing 210093 (China); Qiang Zhu, Li, E-mail: lqzhu@nimte.ac.cn [Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Shi, Yi [School of Electronic Science and Engineering, Nanjing University, Nanjing 210093 (China)

    2014-03-31

    Solution-processed sodium alginate electrolyte film shows a high proton conductivity of ∼5.5 × 10{sup −3} S/cm and a high lateral electric-double-layer (EDL) capacitance of ∼2.0 μF/cm{sup 2} at room temperature with a relative humidity of 57%. Low-voltage in-plane-gate indium-zinc-oxide-based EDL transistors laterally gated by sodium alginate electrolytes are fabricated on glass substrates. The field-effect mobility, current ON/OFF ratio, and subthreshold swing of such EDL transistors are estimated to be 4.2 cm{sup 2} V{sup −1} s{sup −1}, 2.8 × 10{sup 6}, and 130 mV/decade, respectively. At last, a low-voltage driven resistor-load inverter is also demonstrated. Such in-plane-gate EDL transistors have potential applications in portable electronics and low-cost biosensors.

  6. Decision Optimization for Power Grid Operating Conditions with High- and Low-Voltage Parallel Loops

    Directory of Open Access Journals (Sweden)

    Dong Yang

    2017-05-01

    Full Text Available With the development of higher-voltage power grids, the high- and low-voltage parallel loops are emerging, which lead to energy losses and even threaten the security and stability of power systems. The multi-infeed high-voltage direct current (HVDC configurations widely appearing in AC/DC interconnected power systems make this situation even worse. Aimed at energy saving and system security, a decision optimization method for power grid operating conditions with high- and low-voltage parallel loops is proposed in this paper. Firstly, considering hub substation distribution and power grid structure, parallel loop opening schemes are generated with GN (Girvan-Newman algorithms. Then, candidate opening schemes are preliminarily selected from all these generated schemes based on a filtering index. Finally, with the influence on power system security, stability and operation economy in consideration, an evaluation model for candidate opening schemes is founded based on analytic hierarchy process (AHP. And a fuzzy evaluation algorithm is used to find the optimal scheme. Simulation results of a New England 39-bus system and an actual power system validate the effectiveness and superiority of this proposed method.

  7. Induction and Conduction Electromagnetic Waves Caused by Lightning Strike on the Low Voltage Network

    Directory of Open Access Journals (Sweden)

    Reynaldo Zoro

    2010-10-01

    Full Text Available Direct and indirect lightning strikes can disturb and induce low voltage overheadlines and it can produced overvoltage due to traveling waves along the lines. This overvoltage can damage the equipments connected to it. It was recorded that there were already a lot of damages of electronic equipments and arrestesr located inside the building of Lightning Measurement Station at Mnt. Tangkuban Perahu. Most of the overvoltage which was developed on the low voltage lines were coming from indirect lightning strike nearby due to the fact that most of the lines were covered by trees. Research was carried out to study and evaluate the induction and conduction of the lightning strikes to the LV lines that can lead to the cause of equipment and arrester damages inside the building. Local lightning data for the analysis were derived from measurement system installed at the stations and historical lightning data from lightning detection network called Jadpen (National Lightning Detection Network. The data was used for calculating and evaluating the voltage elevation, induction voltage profiles and conduction in the form of traveling waves using Rusck Model. Two damaged arresters were evaluated and compared and it give the better understanding on how the protection system work.Keywords: 

  8. The Significance of Breakdown Voltages for Quality Assurance of Low-Voltage BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander A.

    2014-01-01

    Application of thin dielectric, base metal electrode (BME) ceramic capacitors for high-reliability applications requires development of testing procedures that can assure high quality and reliability of the parts. In this work, distributions of breakdown voltages (VBR) in variety of low-voltage BME multilayer ceramic capacitors (MLCCs) have been measured and analyzed. It has been shown that analysis of the distributions can indicate the proportion of defective parts in the lot and significance of the defects. Variations of the distributions after solder dip testing allow for an assessment of the robustness of capacitors to soldering-related stresses. The drawbacks of the existing screening and qualification methods to reveal defects in high-value, low-voltage MLCCs and the importance of VBR measurements are discussed. Analysis has shown that due to a larger concentration of oxygen vacancies, defect-related degradation of the insulation resistance (IR) and failures are more likely in BME compared to the precious metal electrode (PME) capacitors.

  9. DC-link Voltage Control to Compensate Voltage Deviation for PV–BESSs Integrated System in Low-Voltage (LV Networks

    Directory of Open Access Journals (Sweden)

    Lee Gyu-sub

    2016-01-01

    Full Text Available The exhaustion of fossil fuel and the greenhouse gas emission are one of the most significant energy and environmental issues, respectively. Photovoltaic (PV generators and battery energy storage systems (BESSs have been significantly increased for recent years. The BESSs are mainly used for smoothing active power fluctuation of the PV. In this paper, PV–BESSs integration of two DC/DC converters and one AC/DC converter is investigated and DC-link voltage control to compensate the AC voltage deviation is proposed for the PV‒BESS system in low-voltage (LV networks.

  10. Efficiency of high- and low-voltage pulse combinations for gene electrotransfer in muscle, liver, tumor, and skin

    DEFF Research Database (Denmark)

    André, F M; Gehl, J; Sersa, G

    2008-01-01

    Gene electrotransfer is gaining momentum as an efficient methodology for nonviral gene transfer. In skeletal muscle, data suggest that electric pulses play two roles: structurally permeabilizing the muscle fibers and electrophoretically supporting the migration of DNA toward or across the permeab......Gene electrotransfer is gaining momentum as an efficient methodology for nonviral gene transfer. In skeletal muscle, data suggest that electric pulses play two roles: structurally permeabilizing the muscle fibers and electrophoretically supporting the migration of DNA toward or across...... the permeabilized membrane. To investigate this further, combinations of permeabilizing short high-voltage pulses (HV; hundreds of V/cm) and mainly electrophoretic long low-voltage pulses (LV; tens of V/cm) were investigated in muscle, liver, tumor, and skin in rodent models. The following observations were made......, but not to liver; and (4) efficient gene electrotransfer was achieved with HV field strengths below the detectability thresholds for permeabilization; and (5) the lag time interval between the HV and LV pulses decreased sensitivity to the HV pulses, enabling a wider HV amplitude range. In conclusion, HV plus LV...

  11. Low Voltage Ride-Through Capability Solutions for Permanent Magnet Synchronous Wind Generators

    Directory of Open Access Journals (Sweden)

    Victor F. Mendes

    2016-01-01

    Full Text Available Due to the increasing number of wind power plants, several countries have modified their grid codes to include specific requirements for the connection of this technology to the power system. One of the requirements is the ride-through fault capability (RTFC, i.e., the system capability to sustain operation during voltage sags. In this sense, the present paper intends to investigate the behavior of a full-converter wind generator with a permanent magnet synchronous machine during symmetrical and asymmetrical voltage sags. Two solutions to improve the low voltage ride-through capability (LVRT of this technology are analyzed: discharging resistors (brake chopper and resonant controllers (RCs. The design and limitations of these solutions and the others proposed in the literature are discussed. Experimental results in a 34 kW test bench, which represents a scaled prototype of a real 2 MW wind conversion system, are presented.

  12. Solution Processable Electrochemiluminescent Ion Gels for Flexible, Low Voltage, Emissive Displays on Plastic

    Science.gov (United States)

    Moon, Hong Chul; Lodge, Timothy P.; Frisbie, C. Daniel

    2014-03-01

    We have expanded the functionality of ion gels and successfully demonstrated low voltage, flexible electrochemiluminescent (ECL) devices using patterned ECL gels. An ECL device composed of only an emissive gel and two electrodes was fabricated on an ITO-coated substrate by solution casting the ECL gel and brush-painting the top silver electrode. The device turned on at an AC voltage as low as 2.6 V (-1.3 V ~ +1.3 V) and showed a relatively rapid response (sub-ms). Also, we varied the mechanical properties of the ECL gel simply by substituting polystyrene-block-poly(methyl methacrylate)-block-polystyrene (SMS) with commercially available poly(vinylidene fluoride-co-hexafluoropropylene) (P(VDF-co-HFP)), enabling the fabrication of flexible ECL devices on any target substrate by the ``cut-and-stick'' strategy. This simple, rubbery ECL gel should be attractive for flexible electronics applications such as displays on packaging.

  13. A low-voltage high-speed terahertz spatial light modulator using active metamaterial

    Directory of Open Access Journals (Sweden)

    Saroj Rout

    2016-11-01

    Full Text Available An all solid-state metamaterial based terahertz (THz spatial light modulator (SLM is presented which uses high mobility 2DEG to manipulate the metamaterial resonant frequency (0.45 THz leading to terahertz wave modulation. The 2DEG is created by embedding pseudomorphic high-electron mobility transistors in the capacitive gap of each electrical-LC resonator, allowing the charge density to be controlled with very low voltage (1 V and modulating speeds up to 10 MHz while consuming sub-milliwatt power. We have demonstrated our SLM as a 2 × 2 pixel array operating around 0.45 THz by raster scanning a 6 × 6 image of an occluded metal object behind a thick polystyrene screen using a single-pixel THz imaging setup.

  14. Integration of distributed energy resources into low voltage grid: A market-based multiperiod optimization model

    Energy Technology Data Exchange (ETDEWEB)

    Mashhour, Elahe; Moghaddas-Tafreshi, S.M. [Faculty of Electrical Engineering, K.N. Toosi University of Technology, Seyd Khandan, P.O. Box 16315-1355, Shariati, Tehran (Iran)

    2010-04-15

    This paper develops a multiperiod optimization model for an interconnected micro grid with hierarchical control that participates in wholesale energy market to maximize its benefit (i.e. revenues-costs). In addition to the operational constraints of distributed energy resources (DER) including both inter-temporal and non-inter-temporal types, the adequacy and steady-state security constraints of micro grid and its power losses are incorporated in the optimization model. In the presented model, DER are integrated into low voltage grid considering both technical and economical aspects. This integration as a micro grid can participate in wholesale energy market as an entity with dual role including producer and consumer based on the direction of exchanged power. The developed model is evaluated by testing on a micro grid considering different cases and the results are analyzed. (author)

  15. An inductor-based converter with EMI reduction for low-voltage thermoelectric energy harvesting

    Science.gov (United States)

    Wang, Chuang; Zhao, Kai; Li, Zunchao

    2017-07-01

    This paper presents a self-powered inductor-based converter which harvests thermoelectric energy and boosts extremely low voltage to a typical voltage level for supplying body sensor nodes. Electromagnetic interference (EMI) of the converter is reduced by spreading spectrum of fundamental frequency and harmonics via pseudo-random modulation, which is obtained via combining the linear feedback shift register and digitally controlled oscillator. Besides, the methods, namely extracting energy near MPP and reducing the power dissipation, are employed to improve the power efficiency. The presented inductor-based converter is designed and verified in CSMC CMOS 0.18-µm 1P6M process. The results reveal that it achieves the high efficiency and EMI reduction at the same time.

  16. Flow reversal at low voltage and low frequency in a microfabricated ac electrokinetic pump

    DEFF Research Database (Denmark)

    Gregersen, Misha Marie; Olesen, Laurits Højgaard; Brask, Anders

    2007-01-01

    measured in a regime, where both the applied voltage and the frequency are low, Vrms1.5 V and f20 kHz, compared to previously investigated parameter ranges. The impedance spectrum has been thoroughly measured and analyzed in terms of an equivalent circuit diagram to rule out trivial circuit explanations......Microfluidic chips have been fabricated in Pyrex glass to study electrokinetic pumping generated by a low-voltage ac bias applied to an in-channel asymmetric metallic electrode array. A measurement procedure has been established and followed carefully resulting in a high degree of reproducibility...... of the measurements over several days. A large coverage fraction of the electrode array in the microfluidic channels has led to an increased sensitivity allowing for pumping measurements at low bias voltages. Depending on the ionic concentration a hitherto unobserved reversal of the pumping direction has been...

  17. Study on Control Scheme for the Inverters in Low Voltage Microgrid with Nonlinear Loads

    Science.gov (United States)

    Xu, Jiqiang; Lu, Wenzhou; Wu, Lei

    2017-05-01

    There are a lot of nonlinear loads in real low voltage microgrid system. It will cause serious output voltage and grid current harmonic distortions problems in island and grid-connected modes, respectively. To solve this problem, this paper proposes a droop control scheme with quasi-proportion and resonant (quasi-PR) controller based on αβ stationary reference frame to make microgrid smoothly switch between grid-connected and island modes without changing control method. Moreover, in island mode, not only stable output voltage and frequency, but also reduced output voltage harmonics with added nonlinear loads can be achieved; In grid-connected mode, not only constant power, but also reduced grid current harmonics can be achieved. Simulation results verify the effectiveness of the proposed control scheme.

  18. Low-voltage protonic/electronic hybrid indium zinc oxide synaptic transistors on paper substrates

    International Nuclear Information System (INIS)

    Wu, Guodong; Wan, Changjin; Wan, Qing; Zhou, Jumei; Zhu, Liqiang

    2014-01-01

    Low-voltage (1.5 V) indium zinc oxide (IZO)-based electric-double-layer (EDL) thin-film transistors (TFTs) gated by nanogranular proton conducting SiO 2 electrolyte films are fabricated on paper substrates. Both enhancement-mode and depletion-mode operation are obtained by tuning the thickness of the IZO channel layer. Furthermore, such flexible IZO protonic/electronic hybrid EDL TFTs can be used as artificial synapses, and synaptic stimulation response and short-term synaptic plasticity function are demonstrated. The protonic/electronic hybrid EDL TFTs on paper substrates proposed here are promising for low-power flexible paper electronics, artificial synapses and bioelectronics. (paper)

  19. Influence of Crowbar and Chopper Protection on DFIG during Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Rita M. Monteiro Pereira

    2018-04-01

    Full Text Available The energy sector is evolving rapidly, namely due to the increasing importance of renewable energy sources. The connection of large amounts of wind power generation poses new challenges for the dynamic voltage stability analysis of an electric power system, which has to be studied. In this paper, the traditional Doubly-Fed Induction Generator model is employed. Based on this model, a crowbar and chopper circuit is set up to protect the turbine during the short-circuit period. The EUROSTAG software package was used for the simulation studies of the system, and numerical results were obtained. Conclusions are drawn that provide a better understanding of the influence of crowbar and chopper protection on Doubly-Fed Induction Generators (DFIG, during low voltage ride through, in a system with wind power generation.

  20. Development of halogen-free, heat-resistant, low-voltage wire for automotive use

    International Nuclear Information System (INIS)

    Ueno, Keiji; Suzuki, Sizuo; Takahagi, Masatoshi; Uda, Ikujiro

    1995-01-01

    The environmental load of our motorized society is of major concern, and includes considerations of recycling of automotive parts as the industrial wastes. The total average length of AV, AVX (electrical wire insulated with PVC, cross-linked PVC), and AEX (electrical wire insulated with cross-linked polyolefin) wires required for the harnesses in modern automobiles is approximately 2,000-3,000 meters per unit. However these electrical wires contain a large amount of halogen, which can generate the smoke and corrosive gas. In response to this problem the authors have developed the electron beam irradiated halogen-free, heat-resistant, low-voltage electrical wire which does not contain any halogen based polymer or flame retardants. The developed wire features the reliability equivalent to AEX wire with minimum environmental load. (Author)

  1. Low voltage powering of on-detector electronics for HL-LHC experiments upgrades

    CERN Document Server

    Bobillier, Vincent; Vasey, Francois; Karmakar, Sabyasachi; Maity, Manas; Roy, Subhasish; Kundu, Tapas Kumar

    2018-01-01

    All LHC experiments will be upgraded during the next LHC long shutdowns (LS2 and LS3). The increase in resolution and luminosity and the use of more advanced CMOS technology nodes typically implies higher current consumption of the on-detector electronics. In this context, and in view of limiting the cable voltage drop, point-of-load DC-DC converters will be used on detector. This will have a direct impact on the existing powering scheme, implying new AC-DC and/or DC-DC stages as well as changes in the power cabling infrastructure. This paper presents the first results obtained while evaluating different LV powering schemes and distribution layouts for HL-LHC trackers. The precise low voltage power source requirements are being assessed and understood using the CMS tracker upgrade as a use-case.

  2. Ultra Low Voltage Class AB Switched Current Memory Cells Based on Floating Gate Transistors

    DEFF Research Database (Denmark)

    Mucha, Igor

    1999-01-01

    current memory cells were designed using a CMOS process with threshold voltages V-T0n = \\V-T0p\\ = 0.9 V for the n- and p-channel devices. Both hand calculations and PSPICE simulations showed that the designed example switched current memory cell allowed a maximum signal range better than +/-18 mu......A proposal for a class AB switched current memory cell, suitable for ultra-low-voltage applications is presented. The proposal employs transistors with floating gates, allowing to build analog building blocks for ultralow supply voltage operation also in CMOS processes with high threshold voltages....... This paper presents the theoretical basis for the design of "floating-gate'' switched current memory cells by giving a detailed description and analysis of the most important impacts degrading the performance of the cells. To support the theoretical assumptions circuits based on "floating-gate'' switched...

  3. A low-voltage fully balanced CMFF transconductor with improved linearity

    Science.gov (United States)

    Calvo, B.; Celma, S.; Alegre, J. P.; Sanz, M. T.

    2007-05-01

    This paper presents a new low-voltage pseudo-differential continuous-time CMOS transconductor for wideband applications. The proposed cell is based on a feedforward cancellation of the input common-mode signal and keeps the input common mode voltage constant, while the transconductance is easily tunable through a continuous bias voltage. Linearity is preserved during the tuning process for a moderate range of transconductance values. Simulation results for a 0.35 μm CMOS design show a 1:2 G m tuning range with an almost constant bandwidth over 600 MHz. Total harmonic distortion figures are below -60 dB over the whole range at 10 MHz up to a 200 μA p-p differential output. The proposed cell consumes less than 1.2 mW from a single 2.0 V supply.

  4. Merits of CMOS/SIMOX technology for low-voltage SRAM macros

    CERN Document Server

    Kumagai, K; Yamada, T; Nakamura, H; Onishi, H; Matsubara, Y; Imai, K; Kurosawa, S

    1999-01-01

    A 128-kbit SRAM (static random access memory) macro with the 0.35 mu m FD (fully-depleted) CMOS/SIMOX (separation by implantation of oxygen) technology has been developed to demonstrate the merits of that technology for low-voltage $9 applications. Its access time at Vdd =1.5 V was comparable with that obtained with the 0.35 mu m standard bulk CMOS technology at Vdd=3.3 V, due to the combination of the small S/D capacitance and the small back-bias effect. As the $9 yield of the 128-kbit SRAM macros was almost the same as the standard bulk CMOS technology, the manufacturability of the 0.35 mu m FD-CMOS/SIMOX technology has also been demonstrated. (7 refs).

  5. Methods and Strategies for Overvoltage Prevention in Low Voltage Distribution Systems with PV

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob

    2016-01-01

    to handle a high share of PV power. This paper provides an in-depth review of methods and strategies proposed to prevent overvoltage in LV grids with PV, and discusses the effectiveness, advantages, and disadvantages of them in detail. Based on the mathematical framework presented in the paper......, the overvoltage caused by high PV penetration is described, solutions to facilitate higher PV penetration are classified, and their effectiveness, advantages, and disadvantages are illustrated. The investigated solutions include the grid reinforcement, electrical energy storage application, reactive power...... absorption by PV inverters, application of active medium voltage to low voltage (MV/LV) transformers, active power curtailment, and demand response (DR). Coordination between voltage control units by localized, distributed, and centralized voltage control methods is compared using the voltage sensitivity...

  6. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections from...... PVs. In order to increase PV penetration level further, new voltage support control functions for individual inverters are required. This paper investigates distributed reactive power regulation and active power curtailment strategies regarding the development of PV connection capacity by evaluation...... of reactive power efforts and requirement of minimum active power curtailment. Furthermore, a small scale experimental setup is built to reflect real grid interaction in the laboratory by achieving critical types of grid (weak and sufficiently stiff)....

  7. An Optimized Reactive Power Control of Distributed Solar Inverters in Low Voltage Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    This study examines the reactive power ancillary services of solar inverters which are connected to low voltage (LV) distribution networks by giving attention to the grid voltage support service and grid losses. Two typical reference LV distribution network models as suburban and farm...... are introduced from the literature in order to evaluate contribution of two static droop strategies cosφ(P) and Q(U) on the grid voltage. Photovoltaic (PV) hosting capacities of the suburban and farm networks are estimated and the most predominant limitations of connecting more solar inverters are emphasized...... for each network type. Regarding the overloading of MV/LV distribution transformers, overloading of lines and the grid overvoltage limitations, new local grid voltage support methods (cosφ(P,U) and Q(U,P)) are also proposed. Resulting maximum allowable penetration levels with different reactive power...

  8. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... optimization. The proposed method is used to calculate the voltage bands and droop settings of PV inverters at each node by the supervisory controller. The local controller of each PV inverter implements the volt/var control and if necessary, the active power curtailment as per the received settings and based...... on measured local voltages. The advantage of the proposed method is that the calculated reactive power and active power droop settings enable fair contribution of the PV inverters at each node to the voltage regulation. Simulation studies are conducted using DigSilent Power factory software on a simplified...

  9. Design concept for radiation hardening of low power and low voltage dynamic memories

    International Nuclear Information System (INIS)

    Schleifer, H.; Ropp, T.V.D.; Reczek, W.

    1995-01-01

    A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study

  10. Detection of high-impedance fault in low-voltage DC distribution system via mathematical morphology

    Directory of Open Access Journals (Sweden)

    Yun-Sik Oh

    2016-01-01

    Full Text Available This study presents a method for high-impedance fault (HIF detection in a low-voltage DC (LVDC distribution system via mathematical morphology (MM, which is composed of two elementary transformations, namely, dilation and erosion. Various MM-based filters are used to detect abnormal signals of current waveform. The LVDC distribution system, including power conversion devices, such as AC/DC and DC/DC converters, is modelled with electromagnetic transient program (EMTP software to verify the proposed method. The HIF arc model in the DC system is also implemented with EMTP/MODELS, which is a symbolic language interpreter for EMTP. Simulation results show that the proposed method can be applied to detect HIF effectively in the LVDC distribution system.

  11. Study on condition monitoring techniques for low voltage electrical cables in nuclear power plants

    International Nuclear Information System (INIS)

    Hirao, Hideo; Sakai, Takeshi; Kajimura, Yuusaku

    2017-01-01

    Low voltage electrical cables installed in nuclear power plants are required to maintain its function in a design basis accident environment and they are qualified to that environment. The cables degrade also in normal operating conditions due to ageing and they must maintain integrity until the end of their qualified life. Demands for the condition monitoring technique for low voltage electrical cables have therefore been increasing as nuclear power plants operate longer. A single perfect method for this purpose is not available yet, but the possibility to use two different types of methods which can complement with each other has been examined. The combination of Fourier Transform Infrared Spectroscopy (FT-IR) and Indenter Modulus (IM) method was found highly effective. FT-IR is a method that determines chemical properties (changes in molecular bindings) of cables by using infrared rays, while IM is a method that determines mechanical properties (changes in hardness) of cables by indenters. Both methods are non-destructive and can be applied in-situ to the same material. Reliability of the evaluation can be assured by applying two different types of measurement principles that complement with each other. In this study, various cable samples with different kinds of insulation material (cross-linked polyethylene, ethylene propylene rubber, silicone rubber etc.) were aged with a special accelerated ageing technique which applies simultaneous thermal and radiation ageing to simulate ageing phenomena in a more realistic manner, and the degree of ageing was evaluated with FT-IR and IM. The evaluation result shows good correlation with ageing time and other ageing properties for most material types and the effectiveness of these methods were demonstrated. (author)

  12. Robust and Energy-Efficient Ultra-Low-Voltage Circuit Design under Timing Constraints in 65/45 nm CMOS

    Directory of Open Access Journals (Sweden)

    David Bol

    2011-01-01

    Full Text Available Ultra-low-voltage operation improves energy efficiency of logic circuits by a factor of 10×, at the expense of speed, which is acceptable for applications with low-to-medium performance requirements such as RFID, biomedical devices and wireless sensors. However, in 65/45 nm CMOS, variability and short-channel effects significantly harm robustness and timing closure of ultra-low-voltage circuits by reducing noise margins and jeopardizing gate delays. The consequent guardband on the supply voltage to meet a reasonable manufacturing yield potentially ruins energy efficiency. Moreover, high leakage currents in these technologies degrade energy efficiency in case of long stand-by periods. In this paper, we review recently published techniques to design robust and energy-efficient ultra-low-voltage circuits in 65/45 nm CMOS under relaxed yet strict timing constraints.

  13. A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kang, Suk Chull; Goo, Cheol Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, Jin Ho; Park, Jae Seok; Joo, Geum Jong; Park, Chi Seung [KAITEC, Seoul (Korea, Republic of)

    2004-08-15

    Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed

  14. Trap Healing for High-Performance Low-Voltage Polymer Transistors and Solution-Based Analog Amplifiers on Foil.

    Science.gov (United States)

    Pecunia, Vincenzo; Nikolka, Mark; Sou, Antony; Nasrallah, Iyad; Amin, Atefeh Y; McCulloch, Iain; Sirringhaus, Henning

    2017-06-01

    Solution-processed semiconductors such as conjugated polymers have great potential in large-area electronics. While extremely appealing due to their low-temperature and high-throughput deposition methods, their integration in high-performance circuits has been difficult. An important remaining challenge is the achievement of low-voltage circuit operation. The present study focuses on state-of-the-art polymer thin-film transistors based on poly(indacenodithiophene-benzothiadiazole) and shows that the general paradigm for low-voltage operation via an enhanced gate-to-channel capacitive coupling is unable to deliver high-performance device behavior. The order-of-magnitude longitudinal-field reduction demanded by low-voltage operation plays a fundamental role, enabling bulk trapping and leading to compromised contact properties. A trap-reduction technique based on small molecule additives, however, is capable of overcoming this effect, allowing low-voltage high-mobility operation. This approach is readily applicable to low-voltage circuit integration, as this work exemplifies by demonstrating high-performance analog differential amplifiers operating at a battery-compatible power supply voltage of 5 V with power dissipation of 11 µW, and attaining a voltage gain above 60 dB at a power supply voltage below 8 V. These findings constitute an important milestone in realizing low-voltage polymer transistors for solution-based analog electronics that meets performance and power-dissipation requirements for a range of battery-powered smart-sensing applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Surges in low voltage distribution networks: some of conducted studies; Surtos em redes de baixa tensao: alguns estudos realizados

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    This article presents an experience conducted by the Brazilian CELESC - Centrais Electricas de Santa Catarina, by installing two low voltage Si C lightning rods, one near of a batch of distribution transformers, and the other in the protection and measurement cabinet. That installation considered the high number of damages in transformers and meters in a region where 118 days of storm are detected. For the study, two regions presented similar climate characteristics and high number of damaged equipment. The low voltage lightning rods were installed only in one of the regions.

  16. Effect of Transportation and Low Voltage Electrical Stimulation on Meat Quality Characteristics of Omani Sheep

    Directory of Open Access Journals (Sweden)

    Isam T. Kadim

    2010-01-01

    Full Text Available The aim of this study was to determine the effects of road transportation during the hot season (36 oC and low voltage electrical stimulation on meat quality characteristics of Omani sheep. Twenty intact male sheep (1-year old were divided into two equal groups: 3 hrs transported or non-transported. The transported group was transferred to the slaughterhouse the day of slaughter in an open truck covering a distance of approximately 300 km. The non-transported group was kept in a lairage of a commercial slaughterhouse with ad libitum feed and water for 3 days prior to slaughter. Blood samples were collected from the animals before loading and prior to slaughter in order to assess their physiological response to stress in terms of hormonal levels. Fifty percent of the carcasses from each group were randomly assigned to low voltage (90 V at 20 min postmortem. Muscle ultimate pH, expressed juice, cooking loss percentage, WB-shear force value, sarcomere length, myofibrillar fragmentation index and colour L*, a*, b* were measured on samples from Longissimus dorsi muscles collected 24 hrs postmortem at 2-4 oC. The transported sheep had significantly (P<0.05 higher cortisol adrenaline, nor-adrenaline, and dopamine levels than the non-transported group. Muscles from electrically-stimulated carcasses had significantly (P<0.05 lower pH values, longer sarcomere length, lower shear force value, higher expressed juice, myofibrillar fragmentation index and L* values than those from non-stimulated ones. Transportation significantly influenced meat quality characteristics of the Longissimus dorsi muscle. Muscle ultimate pH and shear force values were significantly higher, while CIE L*, a*, b*, expressed juice and cooking loss were lower in transported than non-transported sheep. This study indicated that pre-slaughter transportation at high ambient temperatures can cause noticeable changes in muscle physiology in sheep. Nevertheless, meat quality of transported

  17. Performance and scalability of isolated DC-DC converter topologies in low voltage, high current applications

    Energy Technology Data Exchange (ETDEWEB)

    Vaisanen, V.

    2012-07-01

    Fuel cells are a promising alternative for clean and efficient energy production. A fuel cell is probably the most demanding of all distributed generation power sources. It resembles a solar cell in many ways, but sets strict limits to current ripple, common mode voltages and load variations. The typically low output voltage from the fuel cell stack needs to be boosted to a higher voltage level for grid interfacing. Due to the high electrical efficiency of the fuel cell, there is a need for high efficiency power converters, and in the case of low voltage, high current and galvanic isolation, the implementation of such converters is not a trivial task. This thesis presents galvanically isolated DC-DC converter topologies that have favorable characteristics for fuel cell usage and reviews the topologies from the viewpoint of electrical efficiency and cost efficiency. The focus is on evaluating the design issues when considering a single converter module having large current stresses. The dominating loss mechanism in low voltage, high current applications is conduction losses. In the case of MOSFETs, the conduction losses can be efficiently reduced by paralleling, but in the case of diodes, the effectiveness of paralleling depends strongly on the semiconductor material, diode parameters and output configuration. The transformer winding losses can be a major source of losses if the windings are not optimized according to the topology and the operating conditions. Transformer prototyping can be expensive and time consuming, and thus it is preferable to utilize various calculation methods during the design process in order to evaluate the performance of the transformer. This thesis reviews calculation methods for solid wire, litz wire and copper foil winding losses, and in order to evaluate the applicability of the methods, the calculations are compared against measurements and FEM simulations. By selecting a proper calculation method for each winding type, the winding

  18. Task 5. Grid interconnection of building integrated and other dispersed photovoltaic power systems. Risk analysis of islanding of photovoltaic power systems within low voltage distribution networks

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, N. [Freelance Consultant, Hillside House, Swindon SN1 3QA (United Kingdom); Thornycroft, J. [Halcrow Group Ltd, Burderop Park, Swindon SN4 0QD (United Kingdom); Collinson, A. [EA Technology, Capenhurst Technology Park, Chester CH1 6ES (United Kingdom)

    2002-03-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme presents the results of a risk analysis concerning photovoltaic power systems islanding in low-voltage distribution networks. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. The purpose of this study was to apply formal risk analysis techniques to the issue of islanding of photovoltaic power systems within low voltage distribution networks. The aim was to determine the additional level of risk that islanding could present to the safety of customers and network maintenance staff. The study identified the reliability required for islanding detection and control systems based on standard procedures for developing a safety assurance strategy. The main conclusions are presented and discussed and recommendations are made. The report is concluded with an appendix that lists the relative risks involved.

  19. Low Voltage Electrowetting on Ferroelectric PVDF-HFP Insulator with Highly Tunable Contact Angle Range.

    Science.gov (United States)

    Sawane, Yogesh B; Ogale, Satishchandra B; Banpurkar, Arun G

    2016-09-14

    We demonstrate a consistent electrowetting response on ferroelectric poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) insulator covered with a thin Teflon AF layer. This bilayer exhibits a factor of 3 enhancement in the contact angle modulation compared to that of conventional single-layered Teflon AF dielectric. On the basis of the proposed model the enhancement is attributed to the high value of effective dielectric constant (εeff ≈ 6) of the bilayer. Furthermore, the bilayer dielectric exhibits a hysteresis-free contact angle modulation over many AC voltage cycles. But the contact angle modulation for DC voltage shows a hysteresis because of the field-induced residual polarization in the ferroelectric layer. Finally, we show that a thin bilayer exhibits contact angle modulation of Δθ (U) ≈ 60° at merely 15 V amplitude of AC voltage indicating a potential dielectric for practical low voltage electrowetting applications. A proof of concept confirms electrowetting based rapid mixing of a fluorescent dye in aqueous glycerol solution for 15 V AC signal.

  20. Control Strategy of Three-Phase Photovoltaic Inverter under Low-Voltage Ride-Through Condition

    Directory of Open Access Journals (Sweden)

    Xianbo Wang

    2015-01-01

    Full Text Available The new energy promoting community has recently witnessed a surge of developments in photovoltaic power generation technologies. To fulfill the grid code requirement of photovoltaic inverter under low-voltage ride-through (LVRT condition, by utilizing the asymmetry feature of grid voltage, this paper aims to control both restraining negative sequence current and reactive power fluctuation on grid side to maintain balanced output of inverter. Two mathematical inverter models of grid-connected inverter containing LCL grid-side filter under both symmetrical and asymmetric grid are proposed. PR controller method is put forward based on inverter model under asymmetric grid. To ensure the stable operation of the inverter, grid voltage feedforward method is introduced to restrain current shock at the moment of voltage drop. Stable grid-connected operation and LVRT ability at grid drop have been achieved via a combination of rapid positive and negative sequence component extraction of accurate grid voltage synchronizing signals. Simulation and experimental results have verified the superior effectiveness of our proposed control strategy.

  1. An integrated low-voltage rated HTS DC power system with multifunctions to suit smart grids

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian Xun, E-mail: jxjin@uestc.edu.cn [Center of Applied Superconductivity, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China); Center of Applied Superconductivity and Electrical Engineering, School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731 (China); Chen, Xiao Yuan [School of Engineering, Sichuan Normal University, Chengdu 610101 (China); Qu, Ronghai; Fang, Hai Yang [School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Xin, Ying [Center of Applied Superconductivity, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China)

    2015-03-15

    Highlights: • A novel LVDC HTS power transmission network is presented. • An integrated power system is achieved by using HTS DC cable and SMES. • DC superconducting cable is verified to achieve self-acting fault current limitation. • SMES is verified to achieve fast-response buffering effect under a power fluctuation. • SMES is verified to achieve favorable load voltage protection effect under a fault. - Abstract: A low-voltage rated DC power transmission network integrated with superconducting cables (SCs) and superconducting magnetic energy storage (SMES) devices has been studied with analytic results presented. In addition to the properties of loss-less and high current transportation capacity, the effectively integrated system is formed with a self-acting fault current limitation feature of the SC and a buffering effect of the SMES to power fluctuations. The results obtained show that the integrated system can achieve high-quality power transmission under common power fluctuation conditions with an advanced self-protection feature under short circuit conditions, which is identified to suit especially the smart grid applications.

  2. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  3. Coordinated control for low voltage ride-through of a PMSG-based wind power plant

    Directory of Open Access Journals (Sweden)

    Khagendra Thapa

    2016-01-01

    Full Text Available Wind turbine generators should be kept connected to a power grid, while supporting the voltage recovery in the case of a grid fault to meet low voltage ride-through requirement in some grid codes. This paper proposes a coordinated control scheme that prevents the increase in the DC-link voltage by reducing the active power in the machine side converter of permanent magnet synchronous generators (PMSGs in proportion to the voltage dip at the terminal of PMSGs. The proposed scheme changes the current priorities from the active current to the reactive current to inject more reactive power for a severe fault depending on the voltage dip. In addition, the grid-side converter operates in a voltage control mode with the slope, which is the ratio of reactive current capability to the voltage tolerance around a rated value. Moreover, during the fault, the slope is changed depending on the voltage dip to inject more reactive current. The performance of the proposed scheme is validated for a wind power plant consisting of 20 units of 5-MW PMSGs using an EMTP-RV simulator. The results demonstrate that the scheme enables the PMSGs not only to survive during the fault, but also to provide a dynamic reactive power support.

  4. Irreversible electroporation ablation area enhanced by synergistic high- and low-voltage pulses.

    Directory of Open Access Journals (Sweden)

    Chenguo Yao

    Full Text Available Irreversible electroporation (IRE produced by a pulsed electric field can ablate tissue. In this study, we achieved an enhancement in ablation area by using a combination of short high-voltage pulses (HVPs to create a large electroporated area and long low-voltage pulses (LVPs to ablate the electroporated area. The experiments were conducted in potato tuber slices. Slices were ablated with an array of four pairs of parallel steel electrodes using one of the following four electric pulse protocols: HVP, LVP, synergistic HVP+LVP (SHLVP or LVP+HVP. Our results showed that the SHLVPs more effectively necrotized tissue than either the HVPs or LVPs, even when the SHLVP dose was the same as or lower than the HVP or LVP doses. The HVP and LVP order mattered and only HVPs+LVPs (SHLVPs treatments increased the size of the ablation zone because the HVPs created a large electroporated area that was more susceptible to the subsequent LVPs. Real-time temperature change monitoring confirmed that the tissue was non-thermally ablated by the electric pulses. Theoretical calculations of the synergistic effects of the SHLVPs on tissue ablation were performed. Our proposed SHLVP protocol provides options for tissue ablation and may be applied to optimize the current clinical IRE protocols.

  5. Irreversible electroporation ablation area enhanced by synergistic high- and low-voltage pulses.

    Science.gov (United States)

    Yao, Chenguo; Lv, Yanpeng; Dong, Shoulong; Zhao, Yajun; Liu, Hongmei

    2017-01-01

    Irreversible electroporation (IRE) produced by a pulsed electric field can ablate tissue. In this study, we achieved an enhancement in ablation area by using a combination of short high-voltage pulses (HVPs) to create a large electroporated area and long low-voltage pulses (LVPs) to ablate the electroporated area. The experiments were conducted in potato tuber slices. Slices were ablated with an array of four pairs of parallel steel electrodes using one of the following four electric pulse protocols: HVP, LVP, synergistic HVP+LVP (SHLVP) or LVP+HVP. Our results showed that the SHLVPs more effectively necrotized tissue than either the HVPs or LVPs, even when the SHLVP dose was the same as or lower than the HVP or LVP doses. The HVP and LVP order mattered and only HVPs+LVPs (SHLVPs) treatments increased the size of the ablation zone because the HVPs created a large electroporated area that was more susceptible to the subsequent LVPs. Real-time temperature change monitoring confirmed that the tissue was non-thermally ablated by the electric pulses. Theoretical calculations of the synergistic effects of the SHLVPs on tissue ablation were performed. Our proposed SHLVP protocol provides options for tissue ablation and may be applied to optimize the current clinical IRE protocols.

  6. Low-Voltage High-Performance UV Photodetectors: An Interplay between Grain Boundaries and Debye Length.

    Science.gov (United States)

    Bo, Renheng; Nasiri, Noushin; Chen, Hongjun; Caputo, Domenico; Fu, Lan; Tricoli, Antonio

    2017-01-25

    Accurate detection of UV light by wearable low-power devices has many important applications including environmental monitoring, space to space communication, and defense. Here, we report the structural engineering of ultraporous ZnO nanoparticle networks for fabrication of very low-voltage high-performance UV photodetectors. A record high photo- to dark-current ratio of 3.3 × 10 5 and detectivity of 3.2 × 10 12 Jones at an ultralow operation bias of 2 mV and low UV-light intensity of 86 μW·cm -2 are achieved by controlling the interplay between grain boundaries and surface depletion depth of ZnO nanoscale semiconductors. An optimal window of structural properties is determined by varying the particle size of ultraporous nanoparticle networks from 10 to 42 nm. We find that small electron-depleted nanoparticles (≤40 nm) are necessary to minimize the dark-current; however, the rise in photocurrent is tampered with decreasing particle size due to the increasing density of grain boundaries. These findings reveal that nanoparticles with a size close to twice their Debye length are required for high photo- to dark-current ratio and detectivity, while further decreasing their size decreases the photodetector performance.

  7. Realisation of low-voltage square-root-domain all-pass filters

    Directory of Open Access Journals (Sweden)

    Farooq A. Khanday

    2013-10-01

    Full Text Available Novel l ow-voltage first-order and second-order square-root-domain all-pass filters derived systematically by means of transfer function decomposition and state -space synthesis techniques are proposed. The employment of only a few geometric-mean cells and grounded capacitors permits the circuits to absorb shunt parasitic capacitances, which is desirable for production in monolithic form . The circuits enjoy the features of electronic adjustment of frequency characteristics, wider dynamic range and low-voltage environment operation. The filters are employed to design high-order all-pass filters using cascade approach. First-order low-pass and second-order band-pass filters, being the inherited building blocks of the proposed low-order all-pass filters are also discussed. The behaviour of the filters is evaluated through simulations using Taiwan semiconductor manufacturing company 0.25 μm level-3 complementary metal oxide semiconductor process parameters, where the most important performance factors are considered.

  8. Application of optical diagnosis to aged low-voltage cable insulation in nuclear plants

    International Nuclear Information System (INIS)

    Katagiri, Junichi; Takezawa, Yoshitaka; Shouji, Hiroshi

    2008-01-01

    We have developed a novel non-destructive optical diagnosis technique for low-voltage cable insulations used in nuclear power plants. The key features of this diagnosis are the use of two wavelengths to measure the change in reflective absorbance (ΔA R ), the use of polarized light to measure crystallinity and the use of element volatilizing to measure fluorescence. Chemical kinetics is used to predict the lifetimes of the cable insulations. When cable insulations darken and harden by time degradation, the ΔA R and depolarization parameters increase. This means that the cross-linking density in the cable insulations increases due to deterioration reactions. When the cross-linking density of insulation increases, its elasticity, corresponding to the material's life, increases. Similarly, as the crystallinity increases due to the change in the high-order structure of the insulating resin caused by irradiation, its elongation property decreases. The elongation property of insulation is one of the most important parameters that can be used to evaluate material lifetimes, because it relates to elasticity. The ΔA R correlated with the elongation property, and the correlation coefficient of an accelerated experiment using model pieces was over 0.9. Thus, we concluded that this optical diagnosis should be applied to evaluate the degradation of cable insulations used in nuclear power plants. (author)

  9. An ultra-low-voltage electronic implementation of inertial neuron model with nonmonotonous Liao's activation function.

    Science.gov (United States)

    Kant, Nasir Ali; Dar, Mohamad Rafiq; Khanday, Farooq Ahmad

    2015-01-01

    The output of every neuron in neural network is specified by the employed activation function (AF) and therefore forms the heart of neural networks. As far as the design of artificial neural networks (ANNs) is concerned, hardware approach is preferred over software one because it promises the full utilization of the application potential of ANNs. Therefore, besides some arithmetic blocks, designing AF in hardware is the most important for designing ANN. While attempting to design the AF in hardware, the designs should be compatible with the modern Very Large Scale Integration (VLSI) design techniques. In this regard, the implemented designs should: only be in Metal Oxide Semiconductor (MOS) technology in order to be compatible with the digital designs, provide electronic tunability feature, and be able to operate at ultra-low voltage. Companding is one of the promising circuit design techniques for achieving these goals. In this paper, 0.5 V design of Liao's AF using sinh-domain technique is introduced. Furthermore, the function is tested by implementing inertial neuron model. The performance of the AF and inertial neuron model have been evaluated through simulation results, using the PSPICE software with the MOS transistor models provided by the 0.18-μm Taiwan Semiconductor Manufacturer Complementary Metal Oxide Semiconductor (TSM CMOS) process.

  10. Implementation methodology for interoperable personal health devices with low-voltage low-power constraints.

    Science.gov (United States)

    Martinez-Espronceda, Miguel; Martinez, Ignacio; Serrano, Luis; Led, Santiago; Trigo, Jesús Daniel; Marzo, Asier; Escayola, Javier; Garcia, José

    2011-05-01

    Traditionally, e-Health solutions were located at the point of care (PoC), while the new ubiquitous user-centered paradigm draws on standard-based personal health devices (PHDs). Such devices place strict constraints on computation and battery efficiency that encouraged the International Organization for Standardization/IEEE11073 (X73) standard for medical devices to evolve from X73PoC to X73PHD. In this context, low-voltage low-power (LV-LP) technologies meet the restrictions of X73PHD-compliant devices. Since X73PHD does not approach the software architecture, the accomplishment of an efficient design falls directly on the software developer. Therefore, computational and battery performance of such LV-LP-constrained devices can even be outperformed through an efficient X73PHD implementation design. In this context, this paper proposes a new methodology to implement X73PHD into microcontroller-based platforms with LV-LP constraints. Such implementation methodology has been developed through a patterns-based approach and applied to a number of X73PHD-compliant agents (including weighing scale, blood pressure monitor, and thermometer specializations) and microprocessor architectures (8, 16, and 32 bits) as a proof of concept. As a reference, the results obtained in the weighing scale guarantee all features of X73PHD running over a microcontroller architecture based on ARM7TDMI requiring only 168 B of RAM and 2546 B of flash memory.

  11. Coordinated single-phase control scheme for voltage unbalance reduction in low voltage network.

    Science.gov (United States)

    Pullaguram, Deepak; Mishra, Sukumar; Senroy, Nilanjan

    2017-08-13

    Low voltage (LV) distribution systems are typically unbalanced in nature due to unbalanced loading and unsymmetrical line configuration. This situation is further aggravated by single-phase power injections. A coordinated control scheme is proposed for single-phase sources, to reduce voltage unbalance. A consensus-based coordination is achieved using a multi-agent system, where each agent estimates the averaged global voltage and current magnitudes of individual phases in the LV network. These estimated values are used to modify the reference power of individual single-phase sources, to ensure system-wide balanced voltages and proper power sharing among sources connected to the same phase. Further, the high X / R ratio of the filter, used in the inverter of the single-phase source, enables control of reactive power, to minimize voltage unbalance locally. The proposed scheme is validated by simulating a LV distribution network with multiple single-phase sources subjected to various perturbations.This article is part of the themed issue 'Energy management: flexibility, risk and optimization'. © 2017 The Author(s).

  12. A low-voltage sense amplifier with two-stage operational amplifier clamping for flash memory

    Science.gov (United States)

    Guo, Jiarong

    2017-04-01

    A low-voltage sense amplifier with reference current generator utilizing two-stage operational amplifier clamp structure for flash memory is presented in this paper, capable of operating with minimum supply voltage at 1 V. A new reference current generation circuit composed of a reference cell and a two-stage operational amplifier clamping the drain pole of the reference cell is used to generate the reference current, which avoids the threshold limitation caused by current mirror transistor in the traditional sense amplifier. A novel reference voltage generation circuit using dummy bit-line structure without pull-down current is also adopted, which not only improves the sense window enhancing read precision but also saves power consumption. The sense amplifier was implemented in a flash realized in 90 nm flash technology. Experimental results show the access time is 14.7 ns with power supply of 1.2 V and slow corner at 125 °C. Project supported by the National Natural Science Fundation of China (No. 61376028).

  13. Model Based Optimization of Integrated Low Voltage DC-DC Converter for Energy Harvesting Applications

    Science.gov (United States)

    Jayaweera, H. M. P. C.; Muhtaroğlu, Ali

    2016-11-01

    A novel model based methodology is presented to determine optimal device parameters for the fully integrated ultra low voltage DC-DC converter for energy harvesting applications. The proposed model feasibly contributes to determine the maximum efficient number of charge pump stages to fulfill the voltage requirement of the energy harvester application. The proposed DC-DC converter based power consumption model enables the analytical derivation of the charge pump efficiency when utilized simultaneously with the known LC tank oscillator behavior under resonant conditions, and voltage step up characteristics of the cross-coupled charge pump topology. The verification of the model has been done using a circuit simulator. The optimized system through the established model achieves more than 40% maximum efficiency yielding 0.45 V output with single stage, 0.75 V output with two stages, and 0.9 V with three stages for 2.5 kΩ, 3.5 kΩ and 5 kΩ loads respectively using 0.2 V input.

  14. A novel low-voltage operational amplifier for low-power pipelined ADCs

    International Nuclear Information System (INIS)

    Fan Mingjun; Ren Junyan; Guo Yao; Li Ning; Ye Fan; Li Lian

    2009-01-01

    A novel low-voltage two-stage operational amplifier employing class-AB architecture is presented. The structure utilizes level-shifters and current mirrors to create the class-AB behavior in the first and second stages. With this structure, the transconductances of the two stages are double compared with the normal configuration without class-AB behaviors with the same current consumption. Thus power can be saved and the operation frequency can be increased. The nested cascode miller compensation and symmetric common-mode feedback circuits are used for large unit-gain bandwidth, good phase margin and stability. Simulation results show that the sample-and-hold of the 12-bit 40-Ms/s pipelined ADC using the proposed amplifier consumes only 5.8 mW from 1.2 V power supply with signal-to-noise-and-distortion ratio 89.5 dB, spurious-free dynamic range 95.7 dB and total harmonic distortion -94.3 dB with Nyquist input signal frequency.

  15. Controlled Operation of the Islanded Portion of the International Council on Large Electric Systems (CIGRE Low Voltage Distribution Network

    Directory of Open Access Journals (Sweden)

    Ghullam Mustafa Bhutto

    2017-07-01

    Full Text Available In islanding, a portion of the power network, comprised of the loads and distributed generation (DG units, is isolated from the rest of the power grid and forms a micro grid (MG. In this condition, it becomes essential for the islanded MG to operate in a stable and controlled manner by providing ancillary services. When the MG is cut off from the main grid, the islanding must be detected by the DG units. In this condition it is essential that one of the controllers should be switched to the voltage-frequency (VF control mode. In islanding, the network loses it slack reference and this reference is established by a VF controller. The voltage and the frequency of the islanded MG deviate when disconnected from the transmission grid and these deviations are caused by the load-generation imbalance. The voltage and the frequency of the islanded MG can be restored to the permissible limits if the desired/exceeded amount of active and reactive power is injected/absorbed by the locally available sources in islanded MG. This paper proposes a control strategy which can compensate the voltage and the frequency deviations in the islanded portion of the International Council on Large Electric Systems (CIGRE low voltage distribution network by using advanced power electronics devices such as STATCOMs for Photovoltaic (PV Units and Battery Energy Storage Systems (BESS STATCOMs (for battery units. The selection of the VF controller for the most suitable DG unit of this test network is also presented in this paper, and the effectiveness of the controllers is verified by presenting simulation results using DIgSILENT (DIgSILENT GmbH, Gomaringen, Germany power factory software version 15.0.

  16. A Low-Voltage Ride-Through Control Strategy for Three-Phase Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Afshari, Ehsan; Farhangi, Babak; Yang, Yongheng

    2017-01-01

    similar variations in the dc-link voltage of conventional two-stage PV inverters. In such systems with an electrolytic capacitor in the dc-link, the oscillations of the dc-link voltage with DGF can deteriorate the capacitor lifetime, and thus the entire system. The proposed Low-Voltage Ride-Through (LVRT...

  17. A Comprehensive Review of Low-Voltage-Ride-Through Methods for Fixed-Speed Wind Power Generators

    DEFF Research Database (Denmark)

    Moghadasi, Amirhasan; Sarwat, Arif; Guerrero, Josep M.

    2016-01-01

    This paper presents a comprehensive review of various techniques employed to enhance the low voltage ride through (LVRT) capability of the fixed-speed induction generators (FSIGs)-based wind turbines (WTs), which has a non-negligible 20% contribution of the existing wind energy in the world...

  18. Distributed Control to Ensure Proportional Load Sharing and Improve Voltage Regulation in Low-Voltage DC Microgrids

    DEFF Research Database (Denmark)

    Anand, Sandeep; G. Fernandes, Baylon; Guerrero, Josep M.

    2013-01-01

    DC microgrids are gaining popularity due to high efficiency, high reliability, and easy interconnection of renewable sources as compared to the ac system. Control objectives of dc microgrid are: 1) to ensure equal load sharing (in per unit) among sources; and 2) to maintain low-voltage regulation...

  19. A low-offset low-voltage CMOS Op Amp with rail-to-rail input and output ranges

    NARCIS (Netherlands)

    Holzmann, Peter J.; Wiegerink, Remco J.; Gierkink, Sander L.J.; Wassenaar, R.F.; Stroet, Peter; Stroet, P.M.

    1996-01-01

    A low voltage CMOS op amp is presented. The circuit uses complementary input pairs to achieve a rail-to-rail common mode input voltage range. Special attention has been given to the reduction of the op amp's systematic offset voltage. Gain boost amplifiers are connected in a special way to provide

  20. Thermal Optimized Operation of the Single-Phase Full-Bridge PV Inverter under Low Voltage Ride-Through Mode

    DEFF Research Database (Denmark)

    Wang, Huai; Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    The efficiency of 98% has been reported on transformer-less photovoltaic (PV) inverters and the penetration of grid-connected PV systems is booming as well. In the future, the PV systems are expected to contribute to the grid stability by means of low voltage ride-through operation and grid suppo...

  1. A Low-Voltage Ride-Through Technique for Grid-Connected Converters with Reduced Power Transistors Stress

    DEFF Research Database (Denmark)

    Chen, Hsin-Chih; Lee, Chia-Tse; Cheng, Po-Tai

    2016-01-01

    With more and more distributed energy resources being installed in the utility grid, grid operators start imposing the low-voltage ride-through requirement on such systems to remain grid-connected and inject reactive and/or active current to support grid voltage during fault conditions. This pape...

  2. Low-Voltage, Low-Power, and Wide-Tuning-Range Ring-VCO for Frequency ΔΣ Modulator

    DEFF Research Database (Denmark)

    Tuan Vu, Cao; Wisland, Dag T.; Lande, Tor Sverre

    A low-voltage, low-power, and wide-tuning-range VCO which converts an analog input voltage to phase information for a frequency ΔΣ modulator is proposed in this paper. The VCO is based on a differential ring oscillator, which is improved with modified symmetric load and a positive feedback...

  3. Reliability of supply of switchgear for auxiliary low voltage in substations extra high voltage to high voltage

    Directory of Open Access Journals (Sweden)

    Perić Dragoslav M.

    2015-01-01

    Full Text Available Switchgear for auxiliary low voltage in substations (SS of extra high voltages (EHV to high voltage (HV - SS EHV/HV kV/kV is of special interest for the functioning of these important SS, as it provides a supply for system of protection and other vital functions of SS. The article addresses several characteristic examples involving MV lines with varying degrees of independence of their supply, and the possible application of direct transformation EHV/LV through special voltage transformers. Auxiliary sources such as inverters and diesel generators, which have limited power and expensive energy, are also used for the supply of switchgear for auxiliary low voltage. Corresponding reliability indices are calculated for all examples including mean expected annual engagement of diesel generators. The applicability of certain solutions of switchgear for auxiliary low voltage SS EHV/HV, taking into account their reliability, feasibility and cost-effectiveness is analyzed too. In particular, the analysis of applications of direct transformation EHV/LV for supply of switchgear for auxiliary low voltage, for both new and existing SS EHV/HV.

  4. Results of a literature review on the environmental qualification of low-voltage electric cables

    International Nuclear Information System (INIS)

    Lofaro, R.; Lee, B.; Villaran, M.; Gleason, J.; Aggarwal, S.

    1995-01-01

    In the design of nuclear power plants in the US, safety-related electric equipment must be qualified to provide reasonable assurance it can withstand the effects of a design basis event (DBE) and still be able to perform its prescribed safety function, even if the accident were to occur at the end of its service life. The requirement for environmental qualification (EQ) originates from the General Design Criteria in the Code of Federal Regulations, Title 10, Part 50 (10 CFR 50). The acceptable method of performing the qualification of this equipment has evolved over the years, starting with the NRC Division of Operating Reactors (DOR) Guidelines, which were issued in Bulletin 79--01B, and NUREG-0588 requirements and ending with the current EQ Rule, 10 CFR 50.49. While the EQ methods described in these documents have the same overall objective, there are some notable differences for which a clear technical basis has not been established. One difference is the preaging requirement for equipment prior to LOCA testing. In addition, specific issues related to current EQ practices have been raised by the US NRC which need to be addressed. These issues, which are discussed in detail later in this paper, are related to the sources of conservatism and uncertainty in IEEE Standard 323--1974, which is the qualification standard currently endorsed by the NRC. To address these issues, the NRC Office of Nuclear Reactor Regulation (NRR) implemented a Task Action Plan (TAP), and the Office of Nuclear Reactor Research (RES) initiated a complementary research program. The current focus of this program is on the qualification of low-voltage instrumentation and control cables. These cables were selected since they are not typically replaced on a routine basis, and their degradation could impact plant safety

  5. The Design of Operational Amplifier for Low Voltage and Low Current Sound Energy Harvesting System

    Science.gov (United States)

    Fang, Liew Hui; Rahim, Rosemizi Bin Abd; Isa, Muzamir; Idris Syed Hassan, Syed; Ismail, Baharuddin Bin

    2018-03-01

    The objective of this paper is to design a combination of an operational amplifier (op-amp) with a rectifier used in an alternate current (ac) to direct current (dc) power conversion. The op-amp was designed to specifically work at low voltage and low current for a sound energy harvesting system. The goal of the op-amp design with adjustable gain was to control output voltage based on the objectives of the experiment conducted. The op-amp was designed for minimum power dissipation performance, with the means of increasing the output current when receiving a large amount of load. The harvesting circuits which designed further improved the power output efficiency by shortening the fully charged time needed by a supercapacitor bank. It can fulfil the long-time power demands for low power device. Typically, a small amount of energy sources were converted to electricity and stored in the supercapacitor bank, which was built by 10 pieces of capacitors with 0.22 F each, arranged in parallel connection. The highest capacitance was chosen based on the characteristic that have the longest discharging time to support the applications of a supercapacitor bank. Testing results show that the op-amp can boost the low input ac voltage (∼3.89 V) to high output dc voltage (5.0 V) with output current of 30 mA and stored the electrical energy in a big supercapacitor bank having a total of 2.2 F, effectively. The measured results agree well with the calculated results.

  6. Spatial Relationship of Focal Impulses, Rotors and Low Voltage Zones in Patients With Persistent Atrial Fibrillation.

    Science.gov (United States)

    Schade, Anja; Nentwich, Karin; Costello-Boerrigter, Lisa C; Halbfass, Philipp; Mueller, Patrick; Roos, Markus; Barth, Sebastian; Krug, Joachim; Szoelloesi, Geza-Atilla; Lapp, Harald; Deneke, Thomas

    2016-05-01

    Focal impulses (FI) and rotors are sources associated with the initiation and maintenance of atrial fibrillation (AF). Their ablation results in a lower recurrence rate. The aim of this study was to characterize for the first time the spatial relationship between such sources and atrial low voltage zones (LVZ) representing fibrosis. Twenty-five consecutive patients undergoing their first ablation for persistent AF were included. Voltage mapping of both atria was done during AF. Endocardial mapping of FI and rotors (sources) was performed using a basket catheter and displayed using RhythmView(TM) (Topera Inc.) before ablation. Spatial relationship of LVZ and sources was analyzed. LVZs covered 13 ± 12% of right atrial (RA) endocardial surface and 33 ± 25% of left atrial (LA) endocardial surface. The median number of sources was 1 [1-3] in RA and 3 [1-4] in LA. Of LA sources, 18 (30%) were definitely not associated with LVZs or pulmonary vein (PV) antra. Of RA sources, 32 (84%) were remote from LVZ. During ablation of such sources substantial cycle length (CL) prolongation or AF conversion occurred in 11/23 patients (48%). Altogether, 8/11 (73%) of these pertinent sources were located remotely from LVZ and PV antra. There is a wide discrepancy in distribution of LVZ areas and sites of identified rotors. Site and incidence of FIRM sources appear to be unpredictable with atrial substrate mapping. Further prospective, randomized studies are necessary to elucidate the impact of additional ablation of such sources in patients with persistent or longstanding persistent AF. © 2016 Wiley Periodicals, Inc.

  7. Digital-circuit analysis of short-gate tunnel FETs for low-voltage applications

    International Nuclear Information System (INIS)

    Zhuge, Jing; Huang, Ru; Wang, Yangyuan; Verhulst, Anne S; Vandenberghe, William G; Dehaene, Wim; Groeseneken, Guido

    2011-01-01

    This paper investigates the potential of tunnel field-effect transistors (TFETs), with emphasis on short-gate TFETs, by simulation for low-power digital applications having a supply voltage lower than 0.5 V. A transient study shows that the tunneling current has a negligible contribution in charging and discharging the gate capacitance of TFETs. In spite of a higher resistance region in the short-gate TFET, the gate (dis)charging speed still meets low-voltage application requirements. A circuit analysis is performed on short-gate TFETs with different materials, such as Si, Ge and heterostructures in terms of voltage overshoot, delay, static power, energy consumption and energy delay product (EDP). These results are compared to MOSFET and full-gate TFET performance. It is concluded that short-gate heterostructure TFETs (Ge–source for nTFET, In 0.6 Ga 0.4 As–source for pTFET) are promising candidates to extend the supply voltage to lower than 0.5 V because they combine the advantage of a low Miller capacitance, due to the short-gate structures, and strong drive current in TFETs, due to the narrow bandgap material in the source. At a supply voltage of 0.4 V and for an EOT and channel length of 0.6 nm and 40 nm, respectively, a three-stage inverter chain based on short-gate heterostructure TFETs saves 40% energy consumption per cycle at the same delay and shows 60%–75% improvement of EDP at the same static power, compared to its full-gate counterpart. When compared to the MOSFET, better EDP can be achieved in the heterostructure TFET especially at low static power consumption

  8. Utilization of low voltage D-T neutron generators in neutron physics studies

    Energy Technology Data Exchange (ETDEWEB)

    Singkarat, S.

    1995-08-01

    In a small nuclear laboratory of a developing country a low voltage D-T neutron generator can be a very useful scientific apparatus. Such machines have been used successfully for more than 40 years in teaching and scientific research. The original continuous mode 150-kV D-T neutron generator has been modified to have also a capability of producing 2-ns pulsed neutrons. Together with a carefully designed 10 m long flight path collimator and shielding of a 25 cm diameter {center_dot} 10 cm thick BC-501 neutron detector, the pulsing system was successfully used for measuring the double differential cross-section (DDX) of natural iron for 14.1-MeV neutron from the angle of 30 deg to 150 deg in 10 deg steps. In order to extend the utility of the generator, two methods for converting the almost monoenergetic 14-MeV neutrons to monoenergetic neutrons of lower energy were proposed and tested. The first method uses a pulsed neutron generator and the second method uses an ordinary continuous mode generator. The latter method was successfully used to measure the scintillation light output of a 1.4 cm diameter spherical NE-213 scintillation detector. The neutron generator has also been used in the continuous search for improved neutron detection techniques. There is a proposal, based on Monte Carlo calculations, of using a scintillation fiber for a fast neutron spectrometer. Due to the slender shape of the fiber, the pattern of produced light gives a peak in the pulse height spectrum instead of the well-known rectangular-like distribution, when the fiber is bombarded end-on by a beam of 14-MeV neutrons. Experimental investigations were undertaken. Detailed investigations on the light transportation property of a short fiber were performed. The predicted peak has not yet been found but the fiber detector may be developed as a directional discrimination fast neutron detector. 18 refs.

  9. Fast Self-Synchronization between LowVoltage Microgrid and Inverter using Virtual Synchronous Converter

    Directory of Open Access Journals (Sweden)

    Md Ruhul Amin

    2017-12-01

    Full Text Available In this paper, a fast self-synchronization known as virtual synchronous converter (VSCon between single-phase microgrid and inverter in low-voltage microgrid, has been developed in Matlab/Simulink. The idea is to any phase locked loop (PLL circuit for inverter-microgrid synchronization in order to improve the synchronization time. As known, it is difficult and lengthy process to tune the PLL gain parameters to reach suitable performance for synchronizing among the voltage, phase-angle and frequency between them. Due to this problem, a fast self synchronization technique is needed in order to minimize the time losses at the microgrid connection. Therefore, the VSCon has been developed which is based on the synchronous generator mathematical model but in virtual environment representation. It has been applied in the inverter control for generating switching pattern to the inverter switches in order to respond to the grid voltage for improve the synchronization. For a prove of concept, several simulation tests in MATLAB models have been conducted, in order to see the effectiveness of this VSCon. First test has been conducted, when a 240V, 50Hz frequency grid source is used for observing the self-synchronization the system with the power flows output. Furthermore, the next test is conducted when the grid frequency is changed from the rated frequency at 50Hz to 51Hz and the result shows the VSCon in inverter control takes nearly 40ms to synchronize to this new frequency value. The test on grid phase-angle delay also been tested when ac grid voltage has 150 phase delay. As from all the results, the improved inverter control with VSCon structure is able to have fast and self-synchronized between the invertergrid connection before the power from the inverter can be transferred.

  10. Nonlinear Robust Control for Low Voltage Direct-Current Residential Microgrids with Constant Power Loads

    Directory of Open Access Journals (Sweden)

    Martín-Antonio Rodríguez-Licea

    2018-05-01

    Full Text Available A Direct Current (DC microgrid is a concept derived from a smart grid integrating DC renewable sources. The DC microgrids have three particularities: (1 integration of different power sources and local loads through a DC link; (2 on-site power source generation; and (3 alternating loads (on-off state. This kind of arrangement achieves high efficiency, reliability and versatility characteristics. The key device in the development of the DC microgrid is the power electronic converter (PEC, since it allows an efficient energy conversion between power sources and loads. However, alternating loads with strictly-controlled PECs can provide negative impedance behavior to the microgrid, acting as constant power loads (CPLs, such that the overall closed-loop system becomes unstable. Traditional CPL compensation techniques rely on a damping increment by the adaptation of the source or load voltage level, adding external circuitry or by using some advanced control technique. However, none of them provide a simple and general solution for the CPL problem when abrupt changes in parameters and/or in alternating loads/sources occur. This paper proposes a mathematical modeling and a robust control for the basic PECs dealing with CPLs in continuous conduction mode. In particular, the case of the low voltage residential DC microgrid with CPLs is taken as a benchmark. The proposed controller can be easily tuned for the desired response even by the non-expert. Basic converters with voltage mode control are taken as a basis to show the feasibility of this analysis, and experimental tests on a 100-W testbed include abrupt parameter changes such as input voltage.

  11. A differential low-voltage high gain current-mode integrated RF receiver front-end

    Energy Technology Data Exchange (ETDEWEB)

    Wang Chunhua; Ma Minglin; Sun Jingru; Du Sichun; Guo Xiaorong; He Haizhen, E-mail: wch1227164@sina.com [School of Information Science and Technology, Hunan University, Changsha 410082 (China)

    2011-02-15

    A differential low-voltage high gain current-mode integrated RF front end for an 802.11b WLAN is proposed. It contains a differential transconductance low noise amplifier (G{sub m}-LNA) and a differential current-mode down converted mixer. The single terminal of the G{sub m}-LNA contains just one MOS transistor, two capacitors and two inductors. The gate-source shunt capacitors, C{sub x1} and C{sub x2}, can not only reduce the effects of gate-source C{sub gs} on resonance frequency and input-matching impedance, but they also enable the gate inductance L{sub g1,2} to be selected at a very small value. The current-mode mixer is composed of four switched current mirrors. Adjusting the ratio of the drain channel sizes of the switched current mirrors can increase the gain of the mixer and accordingly increase the gain of RF receiver front-end. The RF front-end operates under 1 V supply voltage. The receiver RFIC was fabricated using a chartered 0.18 {mu}m CMOS process. The integrated RF receiver front-end has a measured power conversion gain of 17.48 dB and an input referred third-order intercept point (IIP3) of -7.02 dBm. The total noise figure is 4.5 dB and the power is only 14 mW by post-simulations. (semiconductor integrated circuits)

  12. Characterization of ultraviolet light cured polydimethylsiloxane films for low-voltage, dielectric elastomer actuators

    Science.gov (United States)

    Töpper, Tino; Wohlfender, Fabian; Weiss, Florian; Osmani, Bekim; Müller, Bert

    2016-04-01

    The reduction the operation voltage has been the key challenge to realize of dielectric elastomer actuators (DEA) for many years - especially for the application fields of robotics, lens systems, haptics and future medical implants. Contrary to the approach of manipulating the dielectric properties of the electrically activated polymer (EAP), we intend to realize low-voltage operation by reducing the polymer thickness to the range of a few hundred nanometers. A study recently published presents molecular beam deposition to reliably grow nanometer-thick polydimethylsiloxane (PDMS) films. The curing of PDMS is realized using ultraviolet (UV) radiation with wavelengths from 180 to 400 nm radicalizing the functional side and end groups. The understanding of the mechanical properties of sub-micrometer-thin PDMS films is crucial to optimize DEAs actuation efficiency. The elastic modulus of UV-cured spin-coated films is measured by nano-indentation using an atomic force microscope (AFM) according to the Hertzian contact mechanics model. These investigations show a reduced elastic modulus with increased indentation depth. A model with a skin-like SiO2 surface with corresponding elastic modulus of (2.29 +/- 0.31) MPa and a bulk modulus of cross-linked PDMS with corresponding elastic modulus of (87 +/- 7) kPa is proposed. The surface morphology is observed with AFM and 3D laser microscopy. Wrinkled surface microstructures on UV-cured PDMS films occur for film thicknesses above (510 +/- 30) nm with an UV-irradiation density of 7.2 10-4 J cm-2 nm-1 at a wavelength of 190 nm.

  13. Low voltage-activated calcium channels gate transmitter release at the dorsal root ganglion sandwich synapse.

    Science.gov (United States)

    Rozanski, Gabriela M; Nath, Arup R; Adams, Michael E; Stanley, Elise F

    2013-11-15

    A subpopulation of dorsal root ganglion (DRG) neurons are intimately attached in pairs and separated solely by thin satellite glial cell membrane septa. Stimulation of one neuron leads to transglial activation of its pair by a bi-, purinergic/glutamatergic synaptic pathway, a transmission mechanism that we term sandwich synapse (SS) transmission. Release of ATP from the stimulated neuron can be attributed to a classical mechanism involving Ca(2+) entry via voltage-gated calcium channels (CaV) but via an unknown channel type. Specific blockers and toxins ruled out CaV1, 2.1 and 2.2. Transmission was, however, blocked by a moderate depolarization (-50 mV) or low-concentration Ni(2+) (0.1 mM). Transmission persisted using a voltage pulse to -40 mV from a holding potential of -80 mV, confirming the involvement of a low voltage-activated channel type and limiting the candidate channel type to either CaV3.2 or a subpopulation of inactivation- and Ni(2+)-sensitive CaV2.3 channels. Resistance of the neuron calcium current and SS transmission to SNX482 argue against the latter. Hence, we conclude that inter-somatic transmission at the DRG SS is gated by CaV3.2 type calcium channels. The use of CaV3 family channels to gate transmission has important implications for the biological function of the DRG SS as information transfer would be predicted to occur not only in response to action potentials but also to sub-threshold membrane voltage oscillations. Thus, the SS synapse may serve as a homeostatic signalling mechanism between select neurons in the DRG and could play a role in abnormal sensation such as neuropathic pain.

  14. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  15. Low voltage aluminium anodes. Optimization of the insert-anode bond

    Energy Technology Data Exchange (ETDEWEB)

    Le Guyader, Herve; Debout, Valerie; Grolleau, Anne-Marie [DCN Cherbourg, Departement 2EI, Place Bruat, BP 440, 50104 Cherbourg-Octeville (France); Pautasso, Jean-Pierre [DGA/CTA 16 bis, avenue Prieur de la Cote D' Or, 94 114 Arcueil Cedex (France)

    2004-07-01

    Zinc or Al/Zn/In sacrificial anodes are widely used to protect submerged marine structures from corrosion. Their Open Circuit Potential range from - 1 V vs. Ag/AgCl for Zn anodes to -1.1 V vs. Ag/AgCl for Al/Zn/In. These potentials are sufficiently electronegative as to reduce the threshold for stress corrosion cracking and/or hydrogen embrittlement, KISCC, especially in the presence of high strength alloys. In the 90's, an extensive research programme was initiated by DGA/DCN to implement a new low voltage material. Laboratory and full scale marine tests performed on industrial castings, as previously reported, led to the development of a new patented Al- 0.1%Ga alloy having a working potential of - 0.80 to - 0.83 V vs. Ag/AgCl. This alloy was also evaluated at full scale at the Naval Research Laboratory anode qualification site in Key West, Fl, and gave satisfactory results. Around 500 cylindrical AlGa anodes were then installed on a submerged marine structure replacing the classical zinc anode. A first inspection, carried out after a few months of service, showed that some of the anodes had not operated as expected, which led to further investigations. The examinations performed indicated that the problem was due to a bad metallurgical compatibility between the insert and the sacrificial materials inducing a poor bond between the anode and the plain rod insert. Progressive loss of contact between the anode and the structure to be protected was then induced by penetration of sea water and corrosion at the anode-insert interface. This phenomenon was aggravated by seawater pressure. Additional studies were therefore launched with two aims: (1) find temporary remedies for the anodes already installed on the structure; (2) correct the anode original design and/or manufacturing process to achieve the maximum performance on new anodes lots. This paper describes the various solutions investigated to improve the insert-anode bond: design of the anode, rugosity and

  16. Utilization of low voltage D-T neutron generators in neutron physics studies

    International Nuclear Information System (INIS)

    Singkarat, S.

    1995-01-01

    In a small nuclear laboratory of a developing country a low voltage D-T neutron generator can be a very useful scientific apparatus. Such machines have been used successfully for more than 40 years in teaching and scientific research. The original continuous mode 150-kV D-T neutron generator has been modified to have also a capability of producing 2-ns pulsed neutrons. Together with a carefully designed 10 m long flight path collimator and shielding of a 25 cm diameter · 10 cm thick BC-501 neutron detector, the pulsing system was successfully used for measuring the double differential cross-section (DDX) of natural iron for 14.1-MeV neutron from the angle of 30 deg to 150 deg in 10 deg steps. In order to extend the utility of the generator, two methods for converting the almost monoenergetic 14-MeV neutrons to monoenergetic neutrons of lower energy were proposed and tested. Both designs used the neutron-proton interaction at a circular surface-of-revolution made of hydrocarbon materials. The first design is for a pulsed neutron generator and the second design is for an ordinary continuous mode generator. The latter method was successfully used to measure the scintillation light output of a 1.4 cm diameter spherical NE-213 scintillation detector. The neutron generator has also been used in the continuous search for improved neutron detection techniques. There is a proposal, based on Monte Carlo calculations, of using a scintillation fiber for a fast neutron spectrometer. Due to the slender shape of the fiber, the pattern of produced light gives a peak in the pulse height spectrum instead of the well-known rectangular-like distribution, when the fiber is bombarded end-on by a beam of 14-MeV neutrons. Experimental investigations were undertaken. Detailed investigations on the light transportation property of a short fiber were performed. The predicted peak has not yet been found but the fiber detector may be developed as a directional discrimination fast neutron

  17. Solution-processable electrochemiluminescent ion gels for flexible, low-voltage, emissive displays on plastic.

    Science.gov (United States)

    Moon, Hong Chul; Lodge, Timothy P; Frisbie, C Daniel

    2014-03-05

    Ion gels comprising ABA triblock copolymers and ionic liquids have received much attention as functional materials in numerous applications, especially as gate dielectrics in organic transistors. Here we have expanded the functionality of ion gels by demonstrating low-voltage, flexible electrochemiluminescent (ECL) devices using patterned ion gels containing redox-active luminophores. The ECL devices consisted only of a 30 μm thick emissive gel and two electrodes and were fabricated on indium tin oxide-coated substrates (e.g., polyester) simply by solution-casting the ECL gel and brush-painting a top Ag electrode. The triblock copolymer employed in the gel was polystyrene-block-poly(methyl methacrylate)-block-polystyrene, where the solvophobic polystyrene end blocks associate into micellar cross-links in the versatile ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMI][TFSI]). An ECL gel containing ~6.25 wt % Ru(bpy)3Cl2 (relative to [EMI][TFSI]) as the luminophore turned on at an AC peak-to-peak voltage as low as 2.6 V (i.e., -1.3 to +1.3 V) and showed a relatively rapid response (sub-ms). The wavelength of maximum emission was 610 nm (red-orange). With the use of an iridium(III) complex, Ir(diFppy)2(bpy)PF6 [diFppy = 2-(2',4'-difluorophenyl)pyridine; bpy = 2,2'-bipyridyl], the emitting color was tuned to a maximum wavelength of 540 nm (green). Moreover, when a blended luminophore system containing a 60:40 mixture of Ru(bpy)3(2+) and Ir(diFppy)2(bpy)(+) was used in the emissive layer, the luminance of red-orange-colored light was enhanced by a factor of 2, which is explained by the generation of the additional excited state Ru(bpy)3(2+)* by a coreactant pathway with Ir(diFppy)2(bpy)(+)* in addition to the usual annihilation pathway. This is the first time that enhanced ECL has been achieved in ion gels (or ionic liquids) using a coreactant. Overall, the results indicate that ECL ion gels are attractive multifunctional materials for

  18. Prevalence and predictors of low voltage zones in the left atrium in patients with atrial fibrillation.

    Science.gov (United States)

    Huo, Yan; Gaspar, Thomas; Pohl, Matthias; Sitzy, Judith; Richter, Utz; Neudeck, Sebastian; Mayer, Julia; Kronborg, Mads Brix; Piorkowski, Christopher

    2017-06-10

    To describe the extent and distribution of low voltage zones (LVZ) in a large cohort of patients undergoing ablation for paroxysmal and persistent atrial fibrillation (AF), and to explore baseline predictors of LVZ in these patients. Consecutive patients who underwent a bipolar voltage map guided AF ablation, were enrolled. Voltage maps were conducted for each patient using 3-dimensional electroanatomical mapping system and LVZ were defined as areas of bipolar voltage voltage zones was present in 58 out of 292 patients with paroxysmal and 134 out of 247 persistent AF (P < 0.001). The area of LVZ was larger in patients with persistent as compare to paroxysmal AF, 5 cm2 (IQR 3-18.6) vs. 12.1 cm2 (IQR 3.6-28.5), P = 0.026, respectively. In the multivariate analysis age (OR 1.07, 95%CI 1.05-1.10, P < 0.001), female gender (OR 2.18, 95%CI 1.38-3.43, P = 0.001), sinoatrial node dysfunction (OR 3.90, 95%CI 1.24-12.21, P = 0.020), larger surface area of left atrium pr. cm2 (OR 1.01, 95%CI 1.00-1.02, P = 0.016), and persistent AF (OR 5.03, 95%CI 3.20-7.90, P<0.001) were associated with presence of LVZ. In a large cohort of patients undergoing ablation for AF, the prevalence of LVZ was higher and LVZ areas larger in patients with persistent as compared with paroxysmal AF. The most frequent localization of LVZ was anterior wall, septum and posterior wall. Presence of LVZ was associated with higher age, female gender, larger LA surface area, and sinoatrial node dysfunction. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  19. Low-voltage, large-strain soft electrothermal actuators based on laser-reduced graphene oxide/Ag particle composites

    Science.gov (United States)

    Wang, Qian; Li, Yu-Tao; Zhang, Tian-Yu; Wang, Dan-Yang; Tian, Ye; Yan, Jun-Chao; Tian, He; Yang, Yi; Yang, Fan; Ren, Tian-Ling

    2018-03-01

    In this paper, low-voltage, large-strain flexible electrothermal actuators (ETAs) based on laser-reduced graphene oxide (LRGO)/Ag particle composites were fabricated in a simple and cost-efficient process. By adding Ag particles to the LRGO, the sheet resistance decreased effectively. Under a driving voltage of 28 V, the actuator obtained a bending angle of 192° within 6 s. Besides, the bending deformation could be precisely controlled by the driving voltage ranging from 10° to 192°. Finally, a gripper composed of two actuators was demonstrated to manipulate a piece of polydimethylsiloxane block. With the advantages of low-voltage, fast-response, and easy-to-manufacture, the graphene based ETAs have a promising application in soft robotics and soft machines.

  20. Input Stage for Low-Voltage, Low-Noise Preamplifiers Based on a Floating-Gate MOS Transistor

    DEFF Research Database (Denmark)

    Igor, Mucha

    1997-01-01

    A novel input stage for low-voltage, low-noise preamplifiers for integrated capacitive sensors is presented. The input stage of the preamplifier employs floating-gate MOS transistors which are capable of storing the operation point of the input stage over several years without any severe degradat......A novel input stage for low-voltage, low-noise preamplifiers for integrated capacitive sensors is presented. The input stage of the preamplifier employs floating-gate MOS transistors which are capable of storing the operation point of the input stage over several years without any severe...... degradation of the performance of the circuit and without the need for a repeating programming. In this way the noise originating from any resistance previously used for the definition of the operating point is avoided completely and, moreover, by avoiding the input high-pass filter both the saturation...

  1. Tungsten oxide proton conducting films for low-voltage transparent oxide-based thin-film transistors

    International Nuclear Information System (INIS)

    Zhang, Hongliang; Wan, Qing; Wan, Changjin; Wu, Guodong; Zhu, Liqiang

    2013-01-01

    Tungsten oxide (WO x ) electrolyte films deposited by reactive magnetron sputtering showed a high room temperature proton conductivity of 1.38 × 10 −4 S/cm with a relative humidity of 60%. Low-voltage transparent W-doped indium-zinc-oxide thin-film transistors gated by WO x -based electrolytes were self-assembled on glass substrates by one mask diffraction method. Enhancement mode operation with a large current on/off ratio of 4.7 × 10 6 , a low subthreshold swing of 108 mV/decade, and a high field-effect mobility 42.6 cm 2 /V s was realized. Our results demonstrated that WO x -based proton conducting films were promising gate dielectric candidates for portable low-voltage oxide-based devices.

  2. Proposal for the award of a contract, without competitive tendering, for the maintenance of low-voltage switchgear

    CERN Document Server

    2003-01-01

    This document concerns the award of a contract, without competitive tendering, for the maintenance of low-voltage switchgear. The Finance Committee is invited to agree to the negotiation of a contract, without competitive tendering, for the maintenance of low-voltage switchgear with HAZEMEYER (FR) for a total amount of 385 000 euros (610 000 Swiss francs), covering an initial period of five years, subject to revision for inflation after 1 January 2007. The contract will include options for two one-year extensions beyond the initial five-year period. The amount in Swiss francs has been calculated using the present rate of exchange. The firm has indicated the following distribution by country of the contract value covered by this adjudication proposal: FR - 100%.

  3. Urban exposure to ELF magnetic field due to high-, medium- and low-voltage electricity supply networks

    International Nuclear Information System (INIS)

    Bottura, V.; Cappio Borlino, M.; Carta, N.; Cerise, L.; Imperial, E.

    2009-01-01

    The regional environment protection agency (ARPA) of the Aosta Valley region in north Italy performed a survey of magnetic field triggered by the power supply network in high, medium and low voltages on the entire area of Aosta town. The electrical distribution system for houses was not however taken into account. The aim of the survey was to evaluate the global population exposure and not simply the assessment of the legal exposure limit compliance. (authors)

  4. Interpolation by a prime factor other than 2 in low-voltage low-power ΣΔ DAC

    DEFF Research Database (Denmark)

    Pracný, Peter; Jørgensen, Ivan Harald Holger; Chen, Liang

    2013-01-01

    This paper presents power optimization of a sigma-delta (ΣΔ) modulator based digital-to-analog converter (DAC) for hearing-aid audio back-end application. In a number of state-of-the-art publications the oversampling ratio (OSR) of the ΣΔ modulator is chosen as a factor of integer power of two...... optimization approach can be used for other low voltage low power portable audio applications (mobile phones, notebook computers etc.)....

  5. A High Resolution Switched Capacitor 1bit Sigma-Delta Modulator for Low-Voltage/Low-Power Applications

    DEFF Research Database (Denmark)

    Furst, Claus Efdmann

    1996-01-01

    A high resolution 1bit Sigma-Delta modulator for low power/low voltage applications is presented. The modulator operates at a supply of 1-1.5V, the current drain is 0.1mA. The maximum resolution is 87dB equivalent to 14 bits of resolution. This is achieved with a signal-band of 5kHz, over-samplin...

  6. Towards low-voltage organic thin film transistors (OTFTs with solution-processed high-k dielectric and interface engineering

    Directory of Open Access Journals (Sweden)

    Yaorong Su

    2015-11-01

    Full Text Available Although impressive progress has been made in improving the performance of organic thin film transistors (OTFTs, the high operation voltage resulting from the low gate capacitance density of traditional SiO2 remains a severe limitation that hinders OTFTs'development in practical applications. In this regard, developing new materials with high-k characteristics at low cost is of great scientific and technological importance in the area of both academia and industry. Here, we introduce a simple solution-based technique to fabricate high-k metal oxide dielectric system (ATO at low-temperature, which can be used effectively to realize low-voltage operation of OTFTs. On the other hand, it is well known that the properties of the dielectric/semiconductor and electrode/semiconductor interfaces are crucial in controlling the electrical properties of OTFTs. By optimizing the above two interfaces with octadecylphosphonic acid (ODPA self-assembled monolayer (SAM and properly modified low-cost Cu, obviously improved device performance is attained in our low-voltage OTFTs. Further more, organic electronic devices on flexible substrates have attracted much attention due to their low-cost, rollability, large-area processability, and so on. Basing on the above results, outstanding electrical performance is achieved in flexible devices. Our studies demonstrate an effective way to realize low-voltage, high-performance OTFTs at low-cost.

  7. Effect of Copper and Silicon on Al-5%Zn Alloy as a Candidate Low Voltage Sacrificial Anode

    Science.gov (United States)

    Pratesa, Yudha; Ferdian, Deni; Togina, Inez

    2017-05-01

    One common method used for corrosion protection is a sacrificial anode. Sacrificial anodes that usually employed in the marine environment are an aluminum alloy sacrificial anode, especially Al-Zn-In. However, the electronegativity of these alloys can cause corrosion overprotection and stress cracking (SCC) on a high-strength steel. Therefore, there is a development of the sacrificial anode aluminum low voltage to reduce the risk of overprotection. The addition of alloying elements such as Cu, Si, and Ge will minimize the possibility of overprotection. This study was conducted to analyze the effect of silicon and copper addition in Al-5Zn. The experiment started from casting the sacrificial anode aluminum uses electrical resistance furnace in a graphite crucible in 800°C. The results alloy was analyzed using Optical emission spectroscopy (OES), Differential scanning calorimetry, electrochemical impedance spectroscopy, and metallography. Aluminum alloy with the addition of a copper alloy is the most suitable and efficient to serve as a low-voltage sacrificial anode aluminum. Charge transfer resistivity of copper is smaller than silicon which indicates that the charge transfer between the metal and the electrolyte is easier t to occur. Also, the current potential values in coupling with steel are also in the criteria range of low-voltage aluminum sacrificial anodes.

  8. An air-breathing single cell small proton exchange membrane fuel cell system with AB5-type metal hydride and an ultra-low voltage input boost converter

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Kazuya; Matsumoto, Satoshi; Miyasaka, Akihiro; Shodai, Takahisa [NTT Energy and Environment System Laboratories, 3-1 Morinosato-Wakamiya Atsugi-shi, Kanagawa (Japan)

    2009-01-01

    A new strategy for increasing the power density of an air-breathing small proton exchange membrane fuel cell (PEMFC) system for the main energy source of portable consumer electronics is presented. The small PEMFC system is composed of a single cell. Utilizing the output voltage of the single cell, we introduce a newly designed ultra-low voltage input boost converter. The boost converter can generate 4.1 V output from input sources with low voltage ranges, such as under 1.0 V. The cathode plate is made from a thin SUS 316L stainless steel plate and has ribs that prevent the cathode from bending. The hydrogen is supplied by a metal hydride (MH) tank cartridge. The MH tank contains highly packed AB5-type MH. The MH tank cartridge has a volume of 13.2 cm{sup 3} and can absorb 6.7 L of hydrogen. The maximum power of the small PEMFC is 4.42 W at room temperature. Using 6.7 L of hydrogen, the small PEMFC can generate 11 Wh of electricity. The power density of the small PEMFC reaches 0.51 Wh cm{sup -3}. And the power density of the whole small PEMFC system, which contains the boost converter, a small Li-ion battery for a load absorber, and a case for the system, reaches 0.14 Wh cm{sup -3}. This value matches that of external Li-ion battery chargers for cell phones. We installed the small PEMFC system in a cell phone and confirmed the operations of calling, receiving, videophone, connecting to the Internet, and watching digital TV. And also confirmed that the small PEMFC system provides approximately 8.25 h of talk time, which is about three times as long as that for the original Li-ion battery. (author)

  9. Analysis of Planar E+I and ER+I Transformers for Low-Voltage High-Current DC/DC Converters with Focus on Winding Losses and Leakage Inductance

    DEFF Research Database (Denmark)

    Pittini, Riccardo; Zhang, Zhe; Ouyang, Ziwei

    2012-01-01

    on winding resistance and leakage inductances which represent the main concerns related to low-voltage high-current applications. The PCB winding design has a one to one turn ratio with no interleaving between primary and secondary windings. The main goal was to determine if ER planar core could provide...... a significant advantage in terms of winding losses compared to planar E cores. Results from finite element analysis highlight that low frequency winding resistance is lower for the ER core since it is dominated by the lower mean turn length however, as the AC-resistance becomes dominating the winding eddy...... more realistic results when computing the winding AC-resistance....

  10. A 32 kb 9T near-threshold SRAM with enhanced read ability at ultra-low voltage operation

    Science.gov (United States)

    Kim, Tony Tae-Hyoung; Lee, Zhao Chuan; Do, Anh Tuan

    2018-01-01

    Ultra-low voltage SRAMs are highly sought-after in energy-limited systems such as battery-powered and self-harvested SoCs. However, ultra-low voltage operation diminishes SRAM read bitline (RBL) sensing margin significantly. This paper tackles this issue by presenting a novel 9T cell with data-independent RBL leakage in combination with an RBL boosting technique for enhancing the sensing margin. The proposed technique automatically tracks process, temperature and voltage (PVT) variations for robust sensing margin enhancement. A test chip fabricated in 65 nm CMOS technology shows that the proposed scheme significantly enlarges the sensing margin compared to the conventional bitline sensing scheme. It also achieves the minimum operating voltage of 0.18 V and the minimum energy consumption of 0.92 J/access at 0.4 V. He received 2016 International Low Power Design Contest Award from ISLPED, a best paper award at 2014 and 2011 ISOCC, 2008 AMD/CICC Student Scholarship Award, 2008 Departmental Research Fellowship from Univ. of Minnesota, 2008 DAC/ISSCC Student Design Contest Award, 2008, 2001, and 1999 Samsung Humantec Thesis Award and, 2005 ETRI Journal Paper of the Year Award. He is an author/co-author of +100 journal and conference papers and has 17 US and Korean patents registered. His current research interests include low power and high performance digital, mixed- mode, and memory circuit design, ultra-low voltage circuits and systems design, variation and aging tolerant circuits and systems, and circuit techniques for 3D ICs. He serves as an associate editor of IEEE Transactions on VLSI Systems. He is an IEEE senior member and the Chair of IEEE Solid-State Circuits Society Singapore Chapter. He has served numerous conferences as a committee member.

  11. Five-Phase Five-Level Open-Winding/Star-Winding Inverter Drive for Low-Voltage/High-Current Applications

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Wheeler, Patrick

    2016-01-01

    This paper work proposed a five-phase five-level open-/star-winding multilevel AC converter suitable for low-voltage/high-current applications. Modular converter consists of classical two-level five-phase voltage source inverter (VSI) with slight reconfiguration to serve as a multilevel converter...... for open-/star-winding loads. Elaborately, per phase of the VSI is built with one additional bi-directional switch (MOSFET/IGBT) and all five legs links to the neutral through two capacitors. The structure allows multilevel generation to five-level output with greater potential for fault tolerability under...

  12. Design of Low Voltage Low Power CMOS OP-AMPS with Rail-to-Rail Input/Output Swing

    OpenAIRE

    Gopalaiah, SV; Shivaprasad, AP; Panigrahi, Sukanta K

    2004-01-01

    A novel input and output biasing circuit to extend the input common mode (CM) voltage range and the output swing to rail-to-rail in a low voltage op-amp in standard CMOS technology is presented. The input biasing circuit uses a Switched Capacitor Based Attenuator (SCBA) approach to establish rail-to-rail common mode input voltage range. And the output biasing circuit uses an Output Driver (OD), with floating bias to give the rail-to-rail swing at output stage. Three different OD schemes in op...

  13. Analysis of Energy and Power Generation in a Photovoltaic Micro installation Interconnected with a Low Voltage Grid

    Directory of Open Access Journals (Sweden)

    Marian Sobierajski

    2015-12-01

    Full Text Available The paper discusses the performance of the 15 kW photovoltaic micro installation located on the roof of building D-1 of the Faculty of Electrical Engineering at Wroclaw University of Technology. The micro installation is connected to the low voltage grid, which supplies the new, air-conditioned building D-20. The paper discusses the energy and power generation output in yearly, monthly, and daily intervals. The micro installation’s output in the summer morning peaks is compared with the daily wind generation against the background of the demand, generation, regulation reserve, and overhauls in the National Power System.

  14. Distributed Low Voltage Ride-Through Operation of Power Converters in Grid-Connected Microgrids under Voltage Sags

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Dragicevic, Tomislav

    2015-01-01

    it can make the MG a contributor in smooth ride through the faults. In this paper, a reactive power support strategy using droop controlled converters is proposed to aid MG riding through three phase symmetrical voltage sags. In such a case, the MGs should inject reactive power to the grid to boost...... the voltage in all phases at AC common bus. However, since the line admittances from each converter to point of common coupling (PCC) are not identical, the injected reactive power may not be equally shared. In order to achieve low voltage ride through (LVRT) capability along with a good power sharing...

  15. Atomically Smooth Epitaxial Ferroelectric Thin Films for the Development of a Nonvolatile, Ultrahigh Density, Fast, Low Voltage, Radiation-Hard Memory

    National Research Council Canada - National Science Library

    Ahn, Charles H

    2006-01-01

    The goal of this research is to fabricate atomically smooth, single crystalline, complex oxide thin film nanostructures for use in a nonvolatile, ultrahigh density, fast, low voltage, radiation-hard memory...

  16. Hysteresis behaviour of low-voltage organic field-effect transistors employing high dielectric constant polymer gate dielectrics

    International Nuclear Information System (INIS)

    Kim, Se Hyun; Yun, Won Min; Kwon, Oh-Kwan; Hong, Kipyo; Yang, Chanwoo; Park, Chan Eon; Choi, Woon-Seop

    2010-01-01

    Here, we report on the fabrication of low-voltage-operating pentacene-based organic field-effect transistors (OFETs) that utilize crosslinked cyanoethylated poly(vinyl alcohol) (CR-V) gate dielectrics. The crosslinked CR-V-based OFET could be operated successfully at low voltages (below 4 V), but abnormal behaviour during device operation, such as uncertainty in the field-effect mobility (μ) and hysteresis, was induced by the slow polarization of moieties embedded in the gate dielectric (e.g. polar functionalities, ionic impurities, water and solvent molecules). In an effort to improve the stability of OFET operation, we measured the dependence of μ and hysteresis on dielectric thickness, CR-V crosslinking conditions and sweep rate of the gate bias. The influence of the CR-V surface properties on μ, hysteresis, and the structural and morphological features of the pentacene layer grown on the gate dielectric was characterized and compared with the properties of pentacene grown on a polystyrene surface.

  17. Novel Interleaved Converter with Extra-High Voltage Gain to Process Low-Voltage Renewable-Energy Generation

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2016-10-01

    Full Text Available This paper presents a novel interleaved converter (NIC with extra-high voltage gain to process the power of low-voltage renewable-energy generators such as photovoltaic (PV panel, wind turbine, and fuel cells. The NIC can boost a low input voltage to a much higher voltage level to inject renewable energy to DC bus for grid applications. Since the NIC has two circuit branches in parallel at frond end to share input current, it is suitable for high power applications. In addition, the NIC is controlled in an interleaving pattern, which has the advantages that the NIC has lower input current ripple, and the frequency of the ripple is twice the switching frequency. Two coupled inductors and two switched capacitors are incorporated to achieve a much higher voltage gain than conventional high step-up converters. The proposed NIC has intrinsic features such as leakage energy totally recycling and low voltage stress on power semiconductor. Thorough theoretical analysis and key parameter design are presented in this paper. A prototype is built for practical measurements to validate the proposed NIC.

  18. Calculation of harmonic losses and ampacity in low-voltage power cables when used for feeding large LED lighting loads

    Directory of Open Access Journals (Sweden)

    N. J. Milardovich

    2014-10-01

    Full Text Available A numerical investigation on the harmonic disturbances in low-voltage cables feeding large LED loads is reported. A frequency domain analysis on several commercially-available LEDs was performed to investigate the signature of the harmonic current injected into the power system. Four-core cables and four single-core cable arrangements (three phases and neutral of small, medium, and large conductor cross sections, with the neutral conductor cross section approximately equal to the half of the phase conductors, were examined. The cables were modelled by using electromagnetic finite-element analysis software. High harmonic power losses (up to 2.5 times the value corresponding to an undistorted current of the same rms value of the first harmonic of the LED current were found. A generalized ampacity model was employed for re-rating the cables. It was found that the cross section of the neutral conductor plays an important role in the derating of the cable ampacity due to the presence of a high-level of triplen harmonics in the distorted current. The ampacity of the cables should be derated by about 40 %, almost independent of the conductor cross sections. The calculation have shown that an incoming widespread use of LED lamps in lighting could create significant additional harmonic losses in the supplying low-voltage lines, and thus more severely harmonic emission limits should be defined for LED lamps.

  19. Low-voltage analog front-end processor design for ISFET-based sensor and H+ sensing applications

    Science.gov (United States)

    Chung, Wen-Yaw; Yang, Chung-Huang; Peng, Kang-Chu; Yeh, M. H.

    2003-04-01

    This paper presents a modular-based low-voltage analog-front-end processor design in a 0.5mm double-poly double-metal CMOS technology for Ion Sensitive Field Effect Transistor (ISFET)-based sensor and H+ sensing applications. To meet the potentiometric response of the ISFET that is proportional to various H+ concentrations, the constant-voltage and constant current (CVCS) testing configuration has been used. Low-voltage design skills such as bulk-driven input pair, folded-cascode amplifier, bootstrap switch control circuits have been designed and integrated for 1.5V supply and nearly rail-to-rail analog to digital signal processing. Core modules consist of an 8-bit two-step analog-digital converter and bulk-driven pre-amplifiers have been developed in this research. The experimental results show that the proposed circuitry has an acceptable linearity to 0.1 pH-H+ sensing conversions with the buffer solution in the range of pH2 to pH12. The processor has a potential usage in battery-operated and portable healthcare devices and environmental monitoring applications.

  20. Characterization of conductive nanobiomaterials derived from viral assemblies by low-voltage STEM imaging and Raman scattering

    International Nuclear Information System (INIS)

    Plascencia-Villa, Germán; Bahena, Daniel; José-Yacamán, Miguel; Carreño-Fuentes, Liliana; Palomares, Laura A; Ramírez, Octavio T

    2014-01-01

    New technologies require the development of novel nanomaterials that need to be fully characterized to achieve their potential. High-resolution low-voltage scanning transmission electron microscopy (STEM) has proven to be a very powerful technique in nanotechnology, but its use for the characterization of nanobiomaterials has been limited. Rotavirus VP6 self-assembles into nanotubular assemblies that possess an intrinsic affinity for Au ions. This property was exploited to produce hybrid nanobiomaterials by the in situ functionalization of recombinant VP6 nanotubes with gold nanoparticles. In this work, Raman spectroscopy and advanced analytical electron microscopy imaging with spherical aberration-corrected (Cs) STEM and nanodiffraction at low-voltage doses were employed to characterize nanobiomaterials. STEM imaging revealed the precise structure and arrangement of the protein templates, as well as the nanostructure and atomic arrangement of gold nanoparticles with high spatial sub-Angstrom resolution and avoided radiation damage. The imaging was coupled with backscattered electron imaging, ultra-high resolution scanning electron microscopy and x-ray spectroscopy. The hybrid nanobiomaterials that were obtained showed unique properties as bioelectronic conductive devices and showed enhanced Raman scattering by their precise arrangement into superlattices, displaying the utility of viral assemblies as functional integrative self-assembled nanomaterials for novel applications. (paper)

  1. Reconnection of the islanded portion of the CIGRE low voltage distribution network

    DEFF Research Database (Denmark)

    Bhutto, G.M.; Bak, Claus Leth; Somro, Duur M.

    2016-01-01

    Islanding is phenomena in which a part of the distribution grid is electrically disconnected from the main transmission system. Islanded operation is encouraged in order to operate the electrical power networks in reliable manners. However, the reliability of the small networks operating is island...... is less as compared to that of the grid connected system. The islanded portion of the distribution network can be reconnected to the transmission grid if the voltage magnitudes, voltage phase angles and the frequencies of the two systems are synchronized. The main objective of this paper is to facilitate...

  2. Management of Power Quality Issues in Low Voltage Networks using Electric Vehicles: Experimental Validation

    DEFF Research Database (Denmark)

    Martinenas, Sergejus; Knezovic, Katarina; Marinelli, Mattia

    2017-01-01

    the existing and future power quality problems. One of the main aspects of the power quality relates to voltage quality. The aim of this work is to experimentally analyse whether series-produced EVs, adhering to contemporary standard and without relying on any V2G capability, can mitigate line voltage drops...... in improving the power quality of a highly unbalanced grid...

  3. Low voltage ride through strategies for SCIG wind turbines in distributed power generation systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Rodriguez, Pedro

    2008-01-01

    Fulfilling the new grid codes constitutes one of the main challenges for the wind power industry, that is specially concerned about the new fault-ride-through requirements. Enhancing the operation of wind-turbines in front of grid faults is not only an important issue for new wind farms, but also...

  4. Conducted EMI Prediction and Mitigation Strategy Based on Transfer Function for a High-Low Voltage DC-DC Converter in Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Li Zhai

    2018-04-01

    Full Text Available The high dv/dt and di/dt outputs from power devices in a high-low voltage DC-DC converter on electric vehicles (EVs can always introduce the unwanted conducted electromagnetic interference (EMI emissions. A conducted EMI prediction and mitigation strategy that is based on transfer function for the high-low voltage DC-DC converter in EVs are proposed. A complete test for the DC-DC converter is conducted to obtain the conducted EMI from DC power cables in the frequency band of 150 kHz-108 MHz. The equivalent circuit with high-frequency parasitic parameters of the DC-DC converter is built`1 based on the measurement results to acquire the characteristics of the conducted EMI of the DC power cables. The common mode (CM and differential mode (DM propagation coupling paths are determined, and the corresponding transfer functions of the DM interference and CM interference are established. The simulation results of the conducted EMI can be obtained by software Matlab and Computer Simulation Technology (CST. By analyzing the transfer functions and the simulation results, the dominated interference is the CM interference, which is the main factor of the conducted EMI. A mitigation strategy for the design of the CM interference filter based on the dominated CM interference is proposed. Finally, the mitigation strategy of the conducted EMI is verified by performing the conducted voltage experiment. From the experiment results, the conducted voltage of the DC power cables is decreased, respectively, by 58 dBμV, 55 dBμV, 65 dBμV, 53 dBμV, and 54 dBμV at frequency 200 kHz, 400 kHz, 600 kHz, 1.4 MHz, and 50 MHz. The conduced voltage in the frequency band of 150 kHz–108 MHz can be mitigated by adding the CM interference filters, and the values are lower than the limit level-3 of CISPR25 standard (GB/T 18655-2010.

  5. An Ultra-Low Voltage Analog Front End for Strain Gauge Sensory System Application in 0.18µm CMOS

    Science.gov (United States)

    Edward, Alexander; Chan, Pak Kwong

    This paper presents analysis and design of a new ultra-low voltage analog front end (AFE) dedicated to strain sensor applications. The AFE, designed in 0.18µm CMOS process, features a chopper-stabilized instrumentation amplifier (IA), a balanced active MOSFET-C 2nd order low pass filter (LPF), a clock generator and a voltage booster which operate at supply voltage (Vdd) of 0.6V. The designed IA achieves 30dB of closed-loop gain, 101dB of common-mode rejection ratio (CMRR) at 50Hz, 80dB of power-supply rejection ratio (PSRR) at 50Hz, thermal noise floor of 53.4 nV/√Hz, current consumption of 14µA, and noise efficiency factor (NEF) of 9.7. The high CMRR and rail-to-rail output swing capability is attributed to a new low voltage realization of the active-bootstrapped technique using a pseudo-differential gain-boosting operational transconductance amplifier (OTA) and proposed current-driven bulk (CDB) biasing technique. An output capacitor-less low-dropout regulator (LDO), with a new fast start-up LPF technique, is used to regulate this 0.6V supply from a 0.8-1.0V energy harvesting power source. It achieves power supply rejection (PSR) of 42dB at frequency of 1MHz. A cascode compensated pseudo differential amplifier is used as the filter's building block for low power design. The filter's single-ended-to-balanced converter is implemented using a new low voltage amplifier with two-stage common-mode cancellation. The overall AFE was simulated to have 65.6dB of signal-to-noise ratio (SNR), total harmonic distortion (THD) of less than 0.9% for a 100Hz sinusoidal maximum input signal, bandwidth of 2kHz, and power consumption of 51.2µW. Spectre RF simulations were performed to validate the design using BSIM3V3 transistor models provided by GLOBALFOUNDRIES 0.18µm CMOS process.

  6. Power grid current harmonics mitigation drawn on low voltage rated switching devices with effortless control

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Hugo S.; Anunciada, Victor; Borges, Beatriz V. [Power Electronics Group, Instituto de Telecomunicacoes, Lisbon (Portugal); Instituto Superior Tecnico - Universidade Tecnica de Lisboa, Lisbon (Portugal)

    2010-01-15

    The great majority of the existing hybrid active power filter solutions is normally focused in 3{phi} systems and, in general, concentrates its domain of application in specific loads with deterministic behavior. Because common use grids do not exhibit these characteristics, it is mandatory to develop solutions for more generic scenarios, encouraging the use of less classical hybrid solutions. In fact, due to the widely use of switch mode converters in a great variety of consumer electronics, the problematic of mains current harmonic mitigation is no longer an exclusive matter of 3{phi} systems. The contribution of this paper is to present a shunt hybrid active power filter topology, initially conceived to work in 1{phi} domestic grids, able to operate the inverter at a voltage rate that can be lower than 10% of the mains voltage magnitude, even under nonspecific working conditions. In addition, the results shown in this paper demonstrate that this topology can, without lack of generality, be suitable to medium voltage (1{phi} or 3{phi}) systems. A new control approach for the proposed topology is discussed in this paper. The control method exhibits an extremely simple architecture requiring single point current sensing only, with no need for any kind of reference. Its practical implementation can be fulfilled by using very few, common use, operational amplifiers. The principle of operation, design criteria, simulation predictions and experimental results are presented and discussed. (author)

  7. CMOS circuits for electromagnetic vibration transducers interfaces for ultra-low voltage energy harvesting

    CERN Document Server

    Maurath, Dominic

    2015-01-01

    Chip-integrated power management solutions are a must for ultra-low power systems. This enables not only the optimization of innovative sensor applications. It is also essential for integration and miniaturization of energy harvesting supply strategies of portable and autonomous monitoring systems. The book particularly addresses interfaces for energy harvesting, which are the key element to connect micro transducers to energy storage elements. Main features of the book are: - A comprehensive technology and application review, basics on transducer mechanics, fundamental circuit and control design, prototyping and testing, up to sensor system supply and applications. - Novel interfacing concepts - including active rectifiers, MPPT methods for efficient tracking of DC as well as AC sources, and a fully-integrated charge pump for efficient maximum AC power tracking at sub-100µW ultra-low power levels. The chips achieve one of widest presented operational voltage range in standard CMOS technology: 0.44V to over...

  8. Modeling of the CIGRE Low Voltage Test Distribution Network and the Development of Appropriate Controllers

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    The fluctuating nature of some of the Distributed Generation (DG) sources can cause power quality related problems like power frequency oscillations, voltage fluctuations etc. In future, the DG penetration is expected to increase and hence this requires some control actions to deal with the power...... controller. The control system is tested in the distribution test network set up by CIGRE. The new approach of the PV controller is done in such a way that it can control AC and DC voltage of the PV converter during dynamic conditions. The battery controller is also developed in such a way that it can...... quality issues. The main focus of this paper is on development of controllers for a distribution system with different DG’s and especially development of a Photovoltaic (PV) controller using a Static Compensator (STATCOM) controller and on modeling of a Battery Storage System (BSS) also based on a STATCOM...

  9. Electric Boiler and Heat Pump Thermo-Electrical Models for Demand Side Management Analysis in Low Voltage Grids

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Bak-Jensen, Birgitte; Chen, Zhe

    2013-01-01

    The last fifteen years many European countries have integrated large percentage of renewable energy on their electricity generation mix. In Denmark the 21.3% of the electricity consumed nowadays is produced by the wind, and it has planned to be the 50% by 2025. In order to front future challenges...... on the power system control and operation, created by this unstable way of generation, Demand Side Management turns to be a promising solution. The storage capacity from thermo-electric units, like electric boilers and heat pumps, allows operating them with certain freedom. Hence they can be employed under...... certain coordination, to actively respond to the power system fluctuations. The following paper presents two simple thermo-electrical models of an electrical boiler and an air-source CO2 heat pump system. The purpose is using them in low voltage grids analysis to assess their capacity and flexibility...

  10. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...... either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load...

  11. A New Approach to High Efficincy in Isolated Boost Converters for High-Power Low-Voltage Fuel Cell Apllications

    DEFF Research Database (Denmark)

    Nymand, Morten; Andersen, Michael A. E.

    2008-01-01

    A new low-leakage-inductance low-resistance design approach to low-voltage high-power isolated boost converters is presented. Very low levels of parasitic circuit inductances are achieved by optimizing transformer design and circuit lay-out. Primary side voltage clamp circuits can be eliminated...... by the use of power MOSFETs fully rated for repetitive avalanche. Voltage rating of primary switches can now be reduced, significantly reducing switch on-state losses. Finally, silicon carbide rectifying diodes allow fast diode turn-off, further reducing losses. Test results from a 1.5 kW full-bridge boost...... converter verify theoretical analysis and demonstrate very high efficiency. Worst case efficiency, at minimum input voltage maximum power, is 96.8 percent and maximum efficiency reaches 98 percent....

  12. Cooperative control of VSC-HVDC connected offshore wind farm with Low-Voltage Ride-Through capability

    DEFF Research Database (Denmark)

    Liu, Yan; Wang, Xiongfei; Chen, Zhe

    2012-01-01

    The Low-Voltage Ride-Through (LVRT) has become an important grid requirement for offshore wind farms connecting with Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) links. In this paper, a cooperative control strategy with LVRT ability is proposed for a VSC-HVDC connected...... variable speed Squirrel-Cage Induction Generator (SCIG) wind farm. The approach employs a DC-link voltage versus offshore AC-bus frequency droop control on the offshore converter of VSC-HVDC link. Thus, the back-to-back converters of SCIG wind turbines can adjust the generated active power based on the AC......-bus frequency deviations, so that a fast power reduction on the wind farm side can be achieved. The EMTDC/PSCAD simulations are performed on a 300 MW offshore variable speed SCIG wind farm. Simulation results confirm the effectiveness of the proposed control method....

  13. Power Flow Analysis for Low-Voltage AC and DC Microgrids Considering Droop Control and Virtual Impedance

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay Kumar; Savaghebi, Mehdi

    2017-01-01

    In the low-voltage (LV) ac microgrids (MGs), with a relatively high R/X ratio, virtual impedance is usually adopted to improve the performance of droop control applied to distributed generators (DGs). At the same time, LV dc MG using virtual impedance as droop control is emerging without adequate...... power flow studies. In this paper, power flow analyses for both ac and dc MGs are formulated and implemented. The mathematical models for both types of MGs considering the concept of virtual impedance are used to be in conformity with the practical control of the DGs. As a result, calculation accuracy...... is improved for both ac and dc MG power flow analyses, comparing with previous methods without considering virtual impedance. Case studies are conducted to verify the proposed power flow analyses in terms of convergence and accuracy. Investigation of the impact to the system of internal control parameters...

  14. Design and implementation of channel estimation for low-voltage power line communication systems based on OFDM

    International Nuclear Information System (INIS)

    Zhao Huidong; Hei Yong; Qiao Shushan; Ye Tianchun

    2012-01-01

    An optimized channel estimation algorithm based on a time-spread structure in OFDM low-voltage power line communication (PLC) systems is proposed to achieve a lower bit error rate (BER). This paper optimizes the best maximum multi-path delay of the linear minimum mean square error (LMMSE) algorithm in time-domain spread OFDM systems. Simulation results indicate that the BER of the improved method is lower than that of conventional LMMSE algorithm, especially when the signal-to-noise ratio (SNR) is lower than 0 dB. Both the LMMSE algorithm and the proposed algorithm are implemented and fabricated in CSMC 0.18 μm technology. This paper analyzes and compares the hardware complexity and performance of the two algorithms. Measurements indicate that the proposed channel estimator has better performance than the conventional estimator.

  15. Interpolating by a factor of 3 in low-voltage low-power ∑Δ DAC

    DEFF Research Database (Denmark)

    Pracný, Peter; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2014-01-01

    This paper presents the power optimization of a sigma-delta (RD) modulator based digital-to-analog converter (DAC) for hearing aid audio back-end application. In a number of state-of-the-art publications the oversampling ratio (OSR) of the RD modulator is chosen as a factor of integer power of two...... by a factor of 3 are investigated. This new design freedom is used to lower the operating frequency of the whole back-end and save considerable amount of power. It is shown that the figure of- merit of such designs can be lower than designs using oversampling by a factor of integer powers of two. The same...... optimization approach can be used for other low voltage low power portable audio applications (mobile phones, notebook computers etc.)....

  16. Low-voltage polymer/small-molecule blend organic thin-film transistors and circuits fabricated via spray deposition

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, By Simon; Anthopoulos, Thomas D., E-mail: t.anthopoulos@ic.ac.uk [Department of Physics and Centre for Plastic Electronics, Imperial College London, South Kensington SW7 2AZ (United Kingdom); Ward, Jeremy W.; Jurchescu, Oana D. [Department of Physics, Wake Forest University, Winston-Salem, North Carolina 27109 (United States); Payne, Marcia M.; Anthony, John E. [Department of Chemistry, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-06-01

    Organic thin-film electronics have long been considered an enticing candidate in achieving high-throughput manufacturing of low-power ubiquitous electronics. However, to achieve this goal, more work is required to reduce operating voltages and develop suitable mass-manufacture techniques. Here, we demonstrate low-voltage spray-cast organic thin-film transistors based on a semiconductor blend of 2,8-difluoro- 5,11-bis (triethylsilylethynyl) anthradithiophene and poly(triarylamine). Both semiconductor and dielectric films are deposited via successive spray deposition in ambient conditions (air with 40%–60% relative humidity) without any special precautions. Despite the simplicity of the deposition method, p-channel transistors with hole mobilities of >1 cm{sup 2}/Vs are realized at −4 V operation, and unipolar inverters operating at −6 V are demonstrated.

  17. Automatic Power-Sharing Modification of P/V Droop Controllers in Low-Voltage Resistive Microgrids

    DEFF Research Database (Denmark)

    L. Vandoorn, Tine; D. M. De Kooning, Jeroen; Meersman, Bart

    2012-01-01

    Microgrids are receiving an increasing interest to integrate the growing share of distributed-generation (DG) units in the electrical network. For the islanded operation of themicrogrid, several control strategies for the primary control have been developed to ensure stable microgrid operation....... In low-voltage (LV) microgrids, active power/voltage ( P/V ) droop controllers are gaining attention as they take the resistive nature of the network lines and the lack of directly coupled rotating inertia into account. However, a problem often cited with these droop controllers is that the grid voltage...... is not a global parameter. This can influence the power sharing between different units. In this paper, it is investigated whether this is actually a disadvantage of the control strategy. It is shown that with / droop control, the DG units that are located electrically far from the load centers automatically...

  18. Design and experimental investigation of a low-voltage thermoelectric energy harvesting system for wireless sensor nodes

    International Nuclear Information System (INIS)

    Guan, Mingjie; Wang, Kunpeng; Xu, Dazheng; Liao, Wei-Hsin

    2017-01-01

    Highlights: • A thermoelectric energy harvesting system for wireless sensor nodes is designed. • An ultra-low voltage self-startup is implemented. • Maximum power point tracking and low power designs are applied for high efficiency. • Efficiency of 44.2–75.4% is obtained with open-circuit voltage of 84–400 mV. • System efficiency is higher than the commercial BQ25504 converter. - Abstract: A thermoelectric energy harvesting system designed to harvest tens of microwatts to several milliwatts from low-voltage thermoelectric generators is presented in this paper. The proposed system is based-on a two-stage boost scheme with self-startup ability. A maximum power point tracking technique based on the open-circuit voltage is adopted in the boost converter for high efficiency. Experimental results indicate that the proposed system can harvest thermoelectric energy and run a microcontroller unit and a wireless sensor node under low input voltage and power with high efficiency. The harvest system and wireless sensor node can be self-powered with minimum thermoelectric open-circuit voltage as 62 mV and input power of 84 μW. With a self-startup scheme, the proposed system can self-start with a 20 mV input voltage. Low power designs are applied in the system to reduce the quiescent dissipation power. It results in better performance considering the conversion efficiency and self-startup ability compared to commercial boost systems used for thermal energy harvesting.

  19. Analysis and modeling of low voltage electrical network at power line carrier frequencies (3-148.5 kHz); Analyse et modelisation du reseau basse tension aux frequences courants porteurs (3 KHZ-148,5 KHZ)

    Energy Technology Data Exchange (ETDEWEB)

    Duval, G.

    1998-07-01

    Electricite de France (EdF) wishes to establish a physical communication link between his clients and the EdF centres. The final link, i.e. between the high/low voltage transformation substation and the residential clients, being ensured by carrier currents. With this aim, an analysis and a modeling of the low voltage network at the carrier frequencies (3 kHz - 148.5 kHz) has been performed. This work has been carried out in parallel with an experiment involving 3500 apparatuses that use carrier currents. The diversity of the French low voltage networks and the limitations imposed by the EN50065-1 standard about the use of carrier currents in Europe do not favour the development of such carrier current systems. Disturbing voltages and localized impedances represent the main difficulties to get round. Inside accommodations, domotic carrier currents have a reduced range but a higher disturbance amplitude because of the proximity of appliances. A differential mode to common mode conversion phenomenon has been evidenced which generates network couplings and important electromagnetic fields. Energy lines and cables have been analyzed using numerical models. Load peaks have been analyzed using statistical tools in order to take into account the daily fluctuations. The modeling of the network is made in two steps: a double-wire model is considered first. Then a three-phase model is developed which analyzes the inter-phases coupling and the effect of the distribution of clients' loads on each phase. The results of this model are conformable with measurements except for underground networks. As perspectives of future works and beyond todays standard framework, the techniques that allow a sensible increase of communication flow rates have been reviewed. (J.S.)

  20. Increase in the number of distributed power generation installations in electricity distribution grids - Simulation in a 400 V low-voltage network; Zunahme der dezentralen Energieerzeugungsanlagen in elektrischen Verteilnetzen: Simulationen im 400 V Niederspannungsnetz des ewz

    Energy Technology Data Exchange (ETDEWEB)

    Hoeckel, M.; Luechinger, P.

    2003-07-01

    This is the sixth part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This fifth appendix to the main report presents and discusses the results of simulations made on the basis of the real-life 400 V low-voltage distribution network operated by the public utilities of the City of Zurich, Switzerland. This comprehensive appendix describes the simulation methods used and the basic characteristics of low-voltage networks and distributed generation facilities. The 6 simulation variants used are also described. The results of the simulations are presented in graphical form and provide profiles of voltage and current, active and reactive power and further mains characteristics for varying load conditions. Also, short-circuit simulations and harmonics analysis are discussed.

  1. Identification of some additional loss components in high-power low-voltage permanent magnet generators

    Energy Technology Data Exchange (ETDEWEB)

    Hamalainen, H.

    2013-11-01

    done by dividing the conductor into transposed subconductors. However, this comes with the expense of an increase in the DC resistance. In the doctoral thesis, a new method is presented to minimize the winding losses by applying a litz wire with noninsulated strands. The construction is the same as in a normal litz wire but the insulation between the subconductors has been left out. The idea is that the connection is kept weak to prevent harmful eddy currents from flowing. Moreover, the analytical solution for calculating the AC resistance factor of the litz-wire is supplemented by including an end-winding resistance in the analytical solution. A simple measurement device is developed to measure the AC resistance in the windings. In the case of a litz-wire with originally noninsulated strands, vacuum pressure impregnation (VPI) is used to insulate the subconductors. In one of the two cases studied, the VPI affected the AC resistance factor, but in the other case, it did not have any effect. However, more research is needed to determine the effect of the VPI on litz-wire with noninsulated strands. An empirical model is developed to calculate the AC resistance factor of a single-layer formwound winding. The model includes the end-winding length and the number of strands and turns. The end winding includes the circulating current (eddy currents that are traveling through the whole winding between parallel strands) and the main current. The end-winding length also affects the total AC resistance factor. (orig.)

  2. Solution-processable precursor route for fabricating ultrathin silica film for high performance and low voltage organic transistors

    Institute of Scientific and Technical Information of China (English)

    Shujing Guo; Liqiang Li; Zhongwu Wang; Zeyang Xu; Shuguang Wang; Kunjie Wu; Shufeng Chen; Zongbo Zhang; Caihong Xu; Wenfeng Qiu

    2017-01-01

    Silica is one of the most commonly used materials for dielectric layer in organic thin-film transistors due to its excellent stability,excellent electrical properties,mature preparation process,and good compatibility with organic semiconductors.However,most of conventional preparation methods for silica film are generally performed at high temperature and/or high vacuum.In this paper,we introduce a simple solution spin-coating method to fabricate silica thin film from precursor route,which possesses a low leakage current,high capacitance,and low surface roughness.The silica thin film can be produced in the condition of low temperature and atmospheric environment.To meet various demands,the thickness of film can be adjusted by means of preparation conditions such as the speed of spin-coating and the concentration of solution.The p-type and n-type organic field effect transistors fabricated by using this film as gate electrodes exhibit excellent electrical performance including low voltage and high performance.This method shows great potential for industrialization owing to its characteristic of low consumption and energy saving,time-saving and easy to operate.

  3. Line-to-Line Fault Analysis and Location in a VSC-Based Low-Voltage DC Distribution Network

    Directory of Open Access Journals (Sweden)

    Shi-Min Xue

    2018-03-01

    Full Text Available A DC cable short-circuit fault is the most severe fault type that occurs in DC distribution networks, having a negative impact on transmission equipment and the stability of system operation. When a short-circuit fault occurs in a DC distribution network based on a voltage source converter (VSC, an in-depth analysis and characterization of the fault is of great significance to establish relay protection, devise fault current limiters and realize fault location. However, research on short-circuit faults in VSC-based low-voltage DC (LVDC systems, which are greatly different from high-voltage DC (HVDC systems, is currently stagnant. The existing research in this area is not conclusive, with further study required to explain findings in HVDC systems that do not fit with simulated results or lack thorough theoretical analyses. In this paper, faults are divided into transient- and steady-state faults, and detailed formulas are provided. A more thorough and practical theoretical analysis with fewer errors can be used to develop protection schemes and short-circuit fault locations based on transient- and steady-state analytic formulas. Compared to the classical methods, the fault analyses in this paper provide more accurate computed results of fault current. Thus, the fault location method can rapidly evaluate the distance between the fault and converter. The analyses of error increase and an improved handshaking method coordinating with the proposed location method are presented.

  4. Angle selective backscattered electron contrast in the low-voltage scanning electron microscope: Simulation and experiment for polymers

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Q., E-mail: qwan2@sheffield.ac.uk [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Masters, R.C. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Lidzey, D. [Department of Physics and Astronomy, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Abrams, K.J. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Dapor, M. [European Centre for Theoretical Studies in Nuclear Physics and Related Areas (ECT-FBK) and Trento Institute for Fundamental Physics and Applications (TIFPA-INFN), via Sommarive 18, I-38123 Trento (Italy); Plenderleith, R.A. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Rimmer, S. [Department of Chemistry, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom); Claeyssens, F.; Rodenburg, C. [Department of Material Science and Engineering, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom)

    2016-12-15

    Recently developed detectors can deliver high resolution and high contrast images of nanostructured carbon based materials in low voltage scanning electron microscopes (LVSEM) with beam deceleration. Monte Carlo Simulations are also used to predict under which exact imaging conditions purely compositional contrast can be obtained and optimised. This allows the prediction of the electron signal intensity in angle selective conditions for back-scattered electron (BSE) imaging in LVSEM and compares it to experimental signals. Angle selective detection with a concentric back scattered (CBS) detector is considered in the model in the absence and presence of a deceleration field, respectively. The validity of the model prediction for both cases was tested experimentally for amorphous C and Cu and applied to complex nanostructured carbon based materials, namely a Poly(N-isopropylacrylamide)/Poly(ethylene glycol) Diacrylate (PNIPAM/PEGDA) semi-interpenetration network (IPN) and a Poly(3-hexylthiophene-2,5-diyl) (P3HT) film, to map nano-scale composition and crystallinity distribution by avoiding experimental imaging conditions that lead to a mixed topographical and compositional contrast - Highlights: • An optimised model for nano-scale analysis of beam sensitive materials by LVSEM. • Simulation and separation of composition and topography in a CBS detector. • Selective angle backscattered electron collection for mapping of polymers.

  5. A Low-Power and Low-Voltage Power Management Strategy for On-Chip Micro Solar Cells

    Directory of Open Access Journals (Sweden)

    Ismail Cevik

    2015-01-01

    Full Text Available Fundamental characteristics of on-chip micro solar cell (MSC structures were investigated in this study. Several MSC structures using different layers in three different CMOS processes were designed and fabricated. Effects of PN junction structure and process technology on solar cell performance were measured. Parameters for low-power and low-voltage implementation of power management strategy and boost converter based circuits utilizing fractional voltage maximum power point tracking (FVMPPT algorithm were determined. The FVMPPT algorithm works based on the fraction between the maximum power point operation voltage and the open circuit voltage of the solar cell structure. This ratio is typically between 0.72 and 0.78 for commercially available poly crystalline silicon solar cells that produce several watts of power under typical daylight illumination. Measurements showed that the fractional voltage ratio is much higher and fairly constant between 0.82 and 0.85 for on-chip mono crystalline silicon micro solar cell structures that produce micro watts of power. Mono crystalline silicon solar cell structures were observed to result in better power fill factor (PFF that is higher than 74% indicating a higher energy harvesting efficiency.

  6. Analog Circuit Design Low Voltage Low Power; Short Range Wireless Front-Ends; Power Management and DC-DC

    CERN Document Server

    Roermund, Arthur; Baschirotto, Andrea

    2012-01-01

    The book contains the contribution of 18 tutorials of the 20th workshop on Advances in Analog Circuit Design.  Each part discusses a specific to-date topic on new and valuable design ideas in the area of analog circuit design. Each part is presented by six experts in that field and state of the art information is shared and overviewed. This book is number 20 in this successful series of Analog Circuit Design, providing valuable information and excellent overviews of Low-Voltage Low-Power Data Converters - Chaired by Prof. Anderea Baschirotto, University of Milan-Bicocca Short Range Wireless Front-Ends - Chaired by Prof. Arthur van Roermund, Eindhoven University of Technology Power management and DC-DC - Chaired by Prof. M. Steyaert, Katholieke University Leuven Analog Circuit Design is an essential reference source for analog circuit designers and researchers wishing to keep abreast with the latest development in the field. The tutorial coverage also makes it suitable for use in an advanced design.

  7. Angle selective backscattered electron contrast in the low-voltage scanning electron microscope: Simulation and experiment for polymers

    International Nuclear Information System (INIS)

    Wan, Q.; Masters, R.C.; Lidzey, D.; Abrams, K.J.; Dapor, M.; Plenderleith, R.A.; Rimmer, S.; Claeyssens, F.; Rodenburg, C.

    2016-01-01

    Recently developed detectors can deliver high resolution and high contrast images of nanostructured carbon based materials in low voltage scanning electron microscopes (LVSEM) with beam deceleration. Monte Carlo Simulations are also used to predict under which exact imaging conditions purely compositional contrast can be obtained and optimised. This allows the prediction of the electron signal intensity in angle selective conditions for back-scattered electron (BSE) imaging in LVSEM and compares it to experimental signals. Angle selective detection with a concentric back scattered (CBS) detector is considered in the model in the absence and presence of a deceleration field, respectively. The validity of the model prediction for both cases was tested experimentally for amorphous C and Cu and applied to complex nanostructured carbon based materials, namely a Poly(N-isopropylacrylamide)/Poly(ethylene glycol) Diacrylate (PNIPAM/PEGDA) semi-interpenetration network (IPN) and a Poly(3-hexylthiophene-2,5-diyl) (P3HT) film, to map nano-scale composition and crystallinity distribution by avoiding experimental imaging conditions that lead to a mixed topographical and compositional contrast - Highlights: • An optimised model for nano-scale analysis of beam sensitive materials by LVSEM. • Simulation and separation of composition and topography in a CBS detector. • Selective angle backscattered electron collection for mapping of polymers.

  8. Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

    Directory of Open Access Journals (Sweden)

    Zhan-Feng Song

    2012-11-01

    Full Text Available A novel control strategy is proposed in this paper for the rotor side converter (RSC of doubly-fed induction generator (DFIG-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT capability of DFIGs during great-level grid voltage dips. The strategy consists of a proportional-resonant (PR controller and auxiliary PR controllers. The auxiliary controllers compensate the output voltage of the RSC in case of grid faults, thus limiting the rotor inrush current of DFIG and meeting the requirements of LVRT. Sequential-component decompositions of current are not required in the control system to improve the response of system. Since the resonant compensator is a double-side integrator, the auxiliary controllers can be simplified through coordinate transformation. The feasibility of the control strategy is validated by simulation on a 1.5 MW wind-turbine driven DFIG system. The impact of the RSC converter voltage rating on the LVRT capability of DFIG is investigated. Meanwhile, the influence of angular frequency detection and control parameters are also discussed. Compared with traditional vector control schemes based on PI current controllers, the presented control strategy effectively suppress rotor current and reduce oscillations of DFIG power and torque under grid faults.

  9. Low voltage operation of IGZO thin film transistors enabled by ultrathin Al2O3 gate dielectric

    Science.gov (United States)

    Ma, Pengfei; Du, Lulu; Wang, Yiming; Jiang, Ran; Xin, Qian; Li, Yuxiang; Song, Aimin

    2018-01-01

    An ultrathin, 5 nm, Al2O3 film grown by atomic-layer deposition was used as a gate dielectric for amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs). The Al2O3 layer showed a low surface roughness of 0.15 nm, a low leakage current, and a high breakdown voltage of 6 V. In particular, a very high gate capacitance of 720 nF/cm2 was achieved, making it possible for the a-IGZO TFTs to not only operate at a low voltage of 1 V but also exhibit desirable properties including a low threshold voltage of 0.3 V, a small subthreshold swing of 100 mV/decade, and a high on/off current ratio of 1.2 × 107. Furthermore, even under an ultralow operation voltage of 0.6 V, well-behaved transistor characteristics were still observed with an on/off ratio as high as 3 × 106. The electron transport through the Al2O3 layer has also been analyzed, indicating the Fowler-Nordheim tunneling mechanism.

  10. A STATCOM with Supercapacitors for Low-Voltage Ride-Through in Fixed-Speed Wind Turbines

    Directory of Open Access Journals (Sweden)

    Andrés Felipe Obando-Montaño

    2014-09-01

    Full Text Available Fixed-speed wind generator (FSWG technology has an important presence in countries where wind energy started to be developed more than a decade ago. This type of technology cannot be directly adapted to the grid codes, for example those requirements related to the immunity level under voltage dips. That behavior is typically referred as low-voltage ride through (LVRT, and it usually implies certain reactive and active power injection requirements, both during a voltage dip and during the voltage recovery. In this context, a review is presented of the LVRT exigencies present in some of the countries with the most advanced grid codes (Denmark, Germany, Spain and the United Kingdom. In this paper, the capabilities of STATCOM-based devices for fulfilling the LVRT requirements in FSWGs are analyzed. For this purpose, two technologies are considered: a STATCOM with a supercapacitor, which improves its energy storage features; and a STATCOM with a supercapacitor and a DC-DC converter, to achieve higher discharge levels.

  11. Ultra-Low Voltage Sixth-Order Low Pass Filter for Sensing the T-Wave Signal in ECGs

    Directory of Open Access Journals (Sweden)

    Panagiotis Bertsias

    2014-11-01

    Full Text Available An ultra-low voltage sixth-order low pass filter topology, suitable for sensing the T-wave signal in an electrocardiogram (ECG, is presented in this paper. This is realized using a cascade connection of second-order building blocks constructed from a sinh-domain two-integrator loop. The performance of the filter has been evaluated using the Cadence Analog Design Environment and the design kit provided by the Austria Mikro Systeme (AMS 0.35-µm CMOS process. The power consumption of filters was 7.21 nW, while a total harmonic distortion (THD level of 4% was observed for an input signal of 220 pA. The RMS value of the input referred noise was 0.43 pA, and the simulated value of the dynamic range (DR was 51.1 dB. A comparison with already published counterparts shows that the proposed topology offers the benefits of 0.5-V supply voltage operation and significantly improved power efficiency.

  12. FDI based on Artificial Neural Network for Low-Voltage-Ride-Through in DFIG-based Wind Turbine.

    Science.gov (United States)

    Adouni, Amel; Chariag, Dhia; Diallo, Demba; Ben Hamed, Mouna; Sbita, Lassaâd

    2016-09-01

    As per modern electrical grid rules, Wind Turbine needs to operate continually even in presence severe grid faults as Low Voltage Ride Through (LVRT). Hence, a new LVRT Fault Detection and Identification (FDI) procedure has been developed to take the appropriate decision in order to develop the convenient control strategy. To obtain much better decision and enhanced FDI during grid fault, the proposed procedure is based on voltage indicators analysis using a new Artificial Neural Network architecture (ANN). In fact, two features are extracted (the amplitude and the angle phase). It is divided into two steps. The first is fault indicators generation and the second is indicators analysis for fault diagnosis. The first step is composed of six ANNs which are dedicated to describe the three phases of the grid (three amplitudes and three angle phases). Regarding to the second step, it is composed of a single ANN which analysis the indicators and generates a decision signal that describes the function mode (healthy or faulty). On other hand, the decision signal identifies the fault type. It allows distinguishing between the four faulty types. The diagnosis procedure is tested in simulation and experimental prototype. The obtained results confirm and approve its efficiency, rapidity, robustness and immunity to the noise and unknown inputs. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Protonic/electronic hybrid oxide transistor gated by chitosan and its full-swing low voltage inverter applications

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Jin Yu [Shanxi Province Key Laboratory High Gravity Chemical Engineering, North University of China, Taiyuan 030051 (China); Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Zhu, Li Qiang, E-mail: lqzhu@nimte.ac.cn; Xiao, Hui [Ningbo Institute of Material Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Yuan, Zhi Guo, E-mail: ncityzg@163.com [Shanxi Province Key Laboratory High Gravity Chemical Engineering, North University of China, Taiyuan 030051 (China)

    2015-12-21

    Modulation of charge carrier density in condensed materials based on ionic/electronic interaction has attracted much attention. Here, protonic/electronic hybrid indium-zinc-oxide (IZO) transistors gated by chitosan based electrolyte were obtained. The chitosan-based electrolyte illustrates a high proton conductivity and an extremely strong proton gating behavior. The transistor illustrates good electrical performances at a low operating voltage of ∼1.0 V such as on/off ratio of ∼3 × 10{sup 7}, subthreshold swing of ∼65 mV/dec, threshold voltage of ∼0.3 V, and mobility of ∼7 cm{sup 2}/V s. Good positive gate bias stress stabilities are obtained. Furthermore, a low voltage driven resistor-loaded inverter was built by using an IZO transistor in series with a load resistor, exhibiting a linear relationship between the voltage gain and the supplied voltage. The inverter is also used for decreasing noises of input signals. The protonic/electronic hybrid IZO transistors have potential applications in biochemical sensors and portable electronics.

  14. Ge/graded-SiGe multiplication layers for low-voltage and low-noise Ge avalanche photodiodes on Si

    Science.gov (United States)

    Miyasaka, Yuji; Hiraki, Tatsurou; Okazaki, Kota; Takeda, Kotaro; Tsuchizawa, Tai; Yamada, Koji; Wada, Kazumi; Ishikawa, Yasuhiko

    2016-04-01

    A new structure is examined for low-voltage and low-noise Ge-based avalanche photodiodes (APDs) on Si, where a Ge/graded-SiGe heterostructure is used as the multiplication layer of a separate-absorption-carrier-multiplication structure. The Ge/SiGe heterojunction multiplication layer is theoretically shown to be useful for preferentially enhancing impact ionization for photogenerated holes injected from the Ge optical-absorption layer via the graded SiGe, reflecting the valence band discontinuity at the Ge/SiGe interface. This property is effective not only for the reduction of operation voltage/electric field strength in Ge-based APDs but also for the reduction of excess noise resulting from the ratio of the ionization coefficients between electrons and holes being far from unity. Such Ge/graded-SiGe heterostructures are successfully fabricated by ultrahigh-vacuum chemical vapor deposition. Preliminary pin diodes having a Ge/graded-SiGe multiplication layer act reasonably as photodetectors, showing a multiplication gain larger than those for diodes without the Ge/SiGe heterojunction.

  15. Low-voltage bendable pentacene thin-film transistor with stainless steel substrate and polystyrene-coated hafnium silicate dielectric.

    Science.gov (United States)

    Yun, Dong-Jin; Lee, Seunghyup; Yong, Kijung; Rhee, Shi-Woo

    2012-04-01

    The hafnium silicate and aluminum oxide high-k dielectrics were deposited on stainless steel substrate using atomic layer deposition process and octadecyltrichlorosilane (OTS) and polystyrene (PS) were treated improve crystallinity of pentacene grown on them. Besides, the effects of the pentacene deposition condition on the morphologies, crystallinities and electrical properties of pentacene were characterized. Therefore, the surface treatment condition on dielectric and pentacene deposition conditions were optimized. The pentacene grown on polystyrene coated high-k dielectric at low deposition rate and temperature (0.2-0.3 Å/s and R.T.) showed the largest grain size (0.8-1.0 μm) and highest crystallinity among pentacenes deposited various deposition conditions, and the pentacene TFT with polystyrene coated high-k dielectric showed excellent device-performance. To decrease threshold voltage of pentacene TFT, the polystyrene-thickness on high-k dielectric was controlled using different concentration of polystyrene solution. As the polystyrene-thickness on hafnium silicate decreases, the dielectric constant of polystyrene/hafnium silicate increases, while the crystallinity of pentacene grown on polystyrene/hafnium silicate did not change. Using low-thickness polystyrene coated hafnium silicate dielectric, the high-performance and low voltage operating (pentacene thin film transistor (μ: ~2 cm(2)/(V s), on/off ratio, >1 × 10(4)) and complementary inverter (DC gains, ~20) could be fabricated.

  16. Space Life Sciences Directorate's Position on the Physiological Effects of Exposing the Crewmemeber to Low-Voltage Electrical Hazards During Extravehicular Activity

    Science.gov (United States)

    Hamilton, Douglas; Kramer, Leonard; Mikatarian, Ron; Polk, James; Duncan, Michael; Koontz, Steven

    2010-01-01

    The models predict that, for low voltage exposures in the space suit, physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work with Naval Health Research Center Detachment Directed Energy Bio-effects Laboratory is being proposed to analyze additional current paths across the human torso and upper limbs. These models may need to be verified with human studies.

  17. Admissibility of building cost subsidy in the power grid above the low voltage level; Zulaessigkeit von Baukostenzuschuessen im Stromnetz oberhalb der Niederspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, Sven [Kanzlei Norton Rose Fulbright LLP, Muenchen(Germany)

    2015-07-01

    Electricity networks are essential to the provision of electrical power to businesses and individuals. In particular for manufacturing businesses a connection to the grid above the low-voltage level is often useful. Network operators demand a subsidy for the new connection and for the change to a higher network level under the auspices of construction cost. The power network market above the low-voltage level is a natural monopoly. This leaves consumers looking for a connection to the power grid with no possibility to select among different network operators. Construction cost subsidies are not regulated by law above the low voltage level. The lack of legal regulation and the natural monopoly above the low-voltage level affect the balance of power between network operators and system users. The lawfulness of the construction cost subsidies, the prerequisites for their demand and a review of the calculation models (Leistungspreismodell, 2-Ebenen-Modell) as well as a proposal for a reform of this system form the subject of this work.

  18. Overvoltage in low voltage systems due to mean voltage manoeuvres; Sobretensoes em sistemas de BT devidas a manobras na media tensao

    Energy Technology Data Exchange (ETDEWEB)

    Pazos, Francisco Jose; Amantegui, Javier; Ferrandis, Francisco; Barona, Amaya [Iberdrola, Madrid (Spain)

    2008-04-15

    The voltage interruption due to mean voltage maneuverers normal operation produces a transient type which is converted in a overvoltage on the low voltage circuit. Nevertheless to be considered a normal phenomena those over voltages have been pointed out as cause for damage in electric home appliances. What are the reasons? Inadequate protection or lack of immunity of the equipment?.

  19. Energy Management System with Equalization Algorithm for Distributed Energy Storage Systems in PV-Active Generator Based Low Voltage DC Microgrids

    DEFF Research Database (Denmark)

    Aldana, Nelson Leonardo Diaz; Hernández, Adriana Carolina Luna; Vasquez, Juan Carlos

    2015-01-01

    This paper presents a centralized strategy for equalizing the state of charge of distributed energy storage systems in an islanded DC microgrid. The proposed strategy is based on a simple algorithm called equalization algorithm, which modifies the charge or discharge rate by weighting the virtual...... results of a low voltage DC microgrid are presented in order to verify the performance of the proposed approach....

  20. A low-voltage Op Amp with rail-to-rail constant-gm input stage and a class AB rail-to-rail output stage

    NARCIS (Netherlands)

    Botma, J.H.; Wassenaar, R.F.; Wiegerink, Remco J.

    1993-01-01

    In this paper a low-voltage two-stage Op Amp is presented. The Op Amp features rail-to-rail operation and has an @put stage with a constant transconductance (%) over the entire common-mode input range. The input stage consists of an n- and a PMOS differential pair connected in parallel. The constant

  1. Decentralized Load Sharing in a Low-Voltage Direct Current Microgrid With an Adaptive Droop Approach Based on a Superimposed Frequency

    DEFF Research Database (Denmark)

    Peyghami, Saeed; Mokhtari, Hossein; Blaabjerg, Frede

    2017-01-01

    Conventional droop methods for load sharing control in low-voltage direct current microgrids suffer from poor power sharing and voltage regulation, especially in the case when operating many dc sources with long feeders. Hence, the communication-based approaches are employed to improve the load s...

  2. Design of village power and micro-grids for rural areas of Zimbabwe with specific attention to voltage regulation on low voltage meshed distribution grids

    Energy Technology Data Exchange (ETDEWEB)

    Tinarwo, David

    2009-07-01

    generation scheme. The results of the simulations showed that the biogas without solar could be most cost effective. In the studied case a great potential of self reliance in terms of energy for the community has been demonstrated. The thesis also looks at some technical aspect of such systems especially when interconnected in different topologies, for example when parallel connected via medium voltage system and also when these are connected in mesh topology in the low voltage. Aspects such as active power sharing, reactive power exchange among these microgrids voltage regulation were studied. Particular attention was given to the study of voltage regulation in low voltage meshed networks using the method of reactive power injection. The method was demonstrated both experimentally and by simulation in ATP - EMTP (Alternative Transient Programme - Electromagnetic Transient Programme). Also the dynamic operation of a biogas fired microturbine was studied to have a clear knowledge of the operation of this since it is the main generating/conversion component of the proposed system. (orig.)

  3. Technical challenges for electric power industries due to grid-integrated electric vehicles in low voltage distributions: A review

    International Nuclear Information System (INIS)

    Haidar, Ahmed M.A.; Muttaqi, Kashem M.; Sutanto, Danny

    2014-01-01

    Highlights: • Grid-Integrated Vehicles (GIVs) as mobile storage systems are briefly discussed. • Comparative analysis on electric vehicles (EVs) and charging systems are provided. • It is necessary to coordinate the GIVs to minimize its impacts on power grid. • A proper load model of EVs that predicts the realistic system behavior is required. • Offering a dual tariff by grid utilities is needed as a way to reduce peak load. - Abstract: Grid-Integrated Vehicles (GIVs) are promising technologies for future Smart Grid (SG) and offer the potential to reduce the environmental impact of vehicles. The large scale deployment of GIVs without proper control of the time to charge the vehicles can result in unexpected challenges. This can lead to a disruptive impact on the current power distribution systems and in particular its substantial impacts in building power energy systems. Therefore, a proper model that predicts the realistic system behavior is required to analysis the true effects of introducing GIVs in the power grid. This paper presents a review of existing studies on GIV systems, their modeling techniques and their effects on power grids. Following a brief overview of the common types of electric vehicles (EVs) with their charging systems, a review of their impact on the low voltage distribution systems will be analyzed. The comprehensive review presented in this paper reveals that the impact of GIVs on power distribution systems can be quantified using the aspects of EVs, such as vehicle penetration, charging time, charging characteristics, driving patterns, transportation network. GIV studies are expected to be more popular in future years with the development of EV technologies and the government support to electricity utilities. Thereby, these factors will reduce the cost of energy to charge EV and enhance the practical implications of GIVs

  4. Battery Storage Systems as Grid-Balancing Measure in Low-Voltage Distribution Grids with Distributed Generation

    Directory of Open Access Journals (Sweden)

    Bernhard Faessler

    2017-12-01

    Full Text Available Due to the promoted integration of renewable sources, a further growth of strongly transient, distributed generation is expected. Thus, the existing electrical grid may reach its physical limits. To counteract this, and to fully exploit the viable potential of renewables, grid-balancing measures are crucial. In this work, battery storage systems are embedded in a grid simulation to evaluate their potential for grid balancing. The overall setup is based on a real, low-voltage distribution grid topology, real smart meter household load profiles, and real photovoltaics load data. An autonomous optimization routine, driven by a one-way communicated incentive, determines the prospective battery operation mode. Different battery positions and incentives are compared to evaluate their impact. The configurations incorporate a baseline simulation without storage, a single, central battery storage or multiple, distributed battery storages which together have the same power and capacity. The incentives address either market conditions, grid balancing, optimal photovoltaic utilization, load shifting, or self-consumption. Simulations show that grid-balancing incentives result in lowest peak-to-average power ratios, while maintaining negligible voltage changes in comparison to a reference case. Incentives reflecting market conditions for electricity generation, such as real-time pricing, negatively influence the power quality, especially with respect to the peak-to-average power ratio. A central, feed-in-tied storage performs better in terms of minimizing the voltage drop/rise and shows lower distribution losses, while distributed storages attached at nodes with electricity generation by photovoltaics achieve lower peak-to-average power ratios.

  5. Electrospraying and ultraviolet light curing of nanometer-thin polydimethylsiloxane membranes for low-voltage dielectric elastomer transducers

    Science.gov (United States)

    Osmani, Bekim; Töpper, Tino; Siketanc, Matej; Kovacs, Gabor M.; Müller, Bert

    2017-04-01

    Dielectric elastomer transducers (DETs) have attracted interest as actuators, sensors, and even as self-sensing actuators for applications in medicine, soft robotics, and microfluidics. To reach strains of more than 10 %, they currently require operating voltages of several hundred volts. In medical applications for artificial muscles, however, their operation is limited to a very few tens of volts, which implies high permittivity materials and thin-film structures. Such micro- or nanostructures can be prepared using electro-spraying, a cost-effective technique that allows upscaling using multiple nozzles for the fabrication of silicone films down to nanometer thickness. Deposition rates of several micrometers per hour have already been reached. It has been recently demonstrated that such membranes can be fabricated by electro-spraying and subsequent ultraviolet light irradiation. Herein, we introduce a relatively fast deposition of a dimethyl silicone copolymer fluid that contains mercaptopropyl side chains in addition to the methyl groups. Its elastic modulus was tuned with the irradiation dose of the 200 W Hg-Xe lamp. We also investigated the formation of elastomer films, using polymer concentrations in ethyl acetate of 1, 2, 5 and 10 vol%. After curing, the surface roughness was measured by means of atomic force microscopy. This instrument also enabled us to determine the average elastic modulus out of, for example, 400 nanoindentation measurements, using a spherical tip with a radius of 500 nm. The elastomer films were cured for a period of less than one minute, a speed that makes it feasible to combine electro-spraying and in situ curing in a single process step for fabricating low-voltage, multilayer DETs.

  6. Heat pump and PV impact on residential low-voltage distribution grids as a function of building and district properties

    International Nuclear Information System (INIS)

    Protopapadaki, Christina; Saelens, Dirk

    2017-01-01

    Highlights: • Comprehensive method includes variability in building and feeder characteristics. • Detailed, 10-min, Modelica-based simulation of buildings, heat pumps and networks. • Overloading and voltage issues appear from 30% heat pumps in rural Belgian feeders. • Analysis of load profiles reveals great impact of heat pump back-up heaters. • High correlation of building neighborhood properties with grid impact indicators. - Abstract: Heating electrification powered by distributed renewable energy generation is considered among potential solutions towards mitigation of greenhouse gas emissions. Roadmaps propose a wide deployment of heat pumps and photovoltaics in the residential sector. Since current distribution grids are not designed to accommodate these loads, potential benefits of such policies might be compromised. However, in large-scale analyses, often grid constraints are neglected. On the other hand, grid impact of heat pumps and photovoltaics has been investigated without considering the influence of building characteristics. This paper aims to assess and quantify in a probabilistic way the impact of these technologies on the low-voltage distribution grid, as a function of building and district properties. The Monte Carlo approach is used to simulate an assortment of Belgian residential feeders, with varying size, cable type, heat pump and PV penetration rates, and buildings of different geometry and insulation quality. Modelica-based models simulate the dynamic behavior of both buildings and heating systems, as well as three-phase unbalanced loading of the network. Additionally, stochastic occupant behavior is taken into account. Analysis of neighborhood load profiles puts into perspective the importance of demand diversity in terms of building characteristics and load simultaneity, highlighting the crucial role of back-up electrical loads. It is shown that air-source heat pumps have a greater impact on the studied feeders than PV, in terms

  7. Conventional P-ω/Q-V Droop Control in Highly Resistive Line of Low-Voltage Converter-Based AC Microgrid

    DEFF Research Database (Denmark)

    Hou, Xiaochao; Sun, Yao; Yuan, Wenbin

    2016-01-01

    -ω/Q-V droop control is adopted in the low-voltage AC microgrid. As a result, the active power sharing among the distributed generators (DGs) is easily obtained without communication. More importantly, this study clears up the previous misunderstanding that conventional P-ω/Q-V droop control is only applicable...... to microgrids with highly inductive lines, and lays a foundation for the application of conventional droop control under different line impedances. Moreover, in order to guarantee the accurate reactive power sharing, a guide for designing Q-V droop gains is given, and virtual resistance is adopted to shape......In low-voltage converter-based alternating current (AC) microgrids with resistive distribution lines, the P-V droop with Q-f boost (VPD/FQB) is the most common method for load sharing. However, it cannot achieve the active power sharing proportionally. To overcome this drawback, the conventional P...

  8. Suppression of the high-frequency disturbances in low-voltage circuits caused by disconnector operation in high-voltage open-air substations

    Energy Technology Data Exchange (ETDEWEB)

    Savic, M.S.

    1986-07-01

    The switching off and on of small capacitive currents charging busbar capacitances, connection conductors and open circuit breakers with disconnectors causes high-frequency transients in high-voltage networks. In low voltage circuits, these transient processes induce dangerous overvoltages for the electronic equipment in the substation. A modified construction of the disconnector with a damping resistor was investigated. Digital simulation of the transient process in a high-voltage network during the arcing period between the disconnector contacts with and without damping resistor were performed. A significant decrease of the arcing duration and the decrease of the electromagnetic field magnitude in the vicinity of the operating disconnector were noticed. In the low voltage circuit protected with the surge arrester, the overvoltage magnitude was not affected by the damping resistor due to the arrester protection effect.

  9. Computer aided method of low voltage power distribution networks protection system against lightning and electromagnetic pulse generated by high altitude nuclear burst

    International Nuclear Information System (INIS)

    Laroubine, J.

    1989-01-01

    The lightning creates an electromagnetic field which produces a slow duration and high energy pulse of current on low voltage power distribution networks. On the other hand an high altitude nuclear burst generates an electromagnetic pulse which causes fast and intense interferences. We describe here the specifications of a passive filter that can reject these interferences. We used a computer aided method of simulation to create a prototype. Experimental results confirm the validity of the model used for simulation [fr

  10. Study of the effect of Pyrophosphate in low voltage Plasma Electrolytic Oxidation on the corrosion resistance of AZ31B Magnesium alloy

    International Nuclear Information System (INIS)

    Yun, Jae Gon; Kim, Eng Chan; Kim, Ki Hong

    2016-01-01

    In this study, low voltage Plasma Electrolytic Oxidation (PEO) was utilized to eliminate the drawbacks of high voltage PEO such as high cost, dimensional deformation, and porosity. Low voltage PEO produces a thin coating, which leads to low corrosion resistance. In order to solve this problem, 0.1⁓0.6 M pyrophosphates were added to a bath containing 1.4 M NaOH and 0.35 M Na_2SiO_3.PEO at 70V was conducted at 25℃ for 3 minutes. The chemical composition, morphology, and corrosion resistance of the anodized coating were analyzed. The anodized film was composed of MgO, Mg_2SiO_4, and Mg_2O_7P_2. Themorphology of the film showed a inappropriately dense structure and low porosity in the anodized layers. It is found that low voltage Plasma Electrolytic Oxidation in cooperation with phosphating treatment can provide good corrosion protection for the AZ31B magnesium alloy.

  11. Study of the effect of Pyrophosphate in low voltage Plasma Electrolytic Oxidation on the corrosion resistance of AZ31B Magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jae Gon; Kim, Eng Chan [Yeungnam University, Gyeongsan (Korea, Republic of); Kim, Ki Hong [Catholic University of Daegu, Gyeongsan (Korea, Republic of)

    2016-01-15

    In this study, low voltage Plasma Electrolytic Oxidation (PEO) was utilized to eliminate the drawbacks of high voltage PEO such as high cost, dimensional deformation, and porosity. Low voltage PEO produces a thin coating, which leads to low corrosion resistance. In order to solve this problem, 0.1⁓0.6 M pyrophosphates were added to a bath containing 1.4 M NaOH and 0.35 M Na{sub 2}SiO{sub 3}.PEO at 70V was conducted at 25℃ for 3 minutes. The chemical composition, morphology, and corrosion resistance of the anodized coating were analyzed. The anodized film was composed of MgO, Mg{sub 2}SiO{sub 4}, and Mg{sub 2}O{sub 7}P{sub 2}. Themorphology of the film showed a inappropriately dense structure and low porosity in the anodized layers. It is found that low voltage Plasma Electrolytic Oxidation in cooperation with phosphating treatment can provide good corrosion protection for the AZ31B magnesium alloy.

  12. Simulator of Non-homogenous Alumina and Current Distribution in an Aluminum Electrolysis Cell to Predict Low-Voltage Anode Effects

    Science.gov (United States)

    Dion, Lukas; Kiss, László I.; Poncsák, Sándor; Lagacé, Charles-Luc

    2018-04-01

    Perfluorocarbons are important contributors to aluminum production greenhouse gas inventories. Tetrafluoromethane and hexafluoroethane are produced in the electrolysis process when a harmful event called anode effect occurs in the cell. This incident is strongly related to the lack of alumina and the current distribution in the cell and can be classified into two categories: high-voltage and low-voltage anode effects. The latter is hard to detect during the normal electrolysis process and, therefore, new tools are necessary to predict this event and minimize its occurrence. This paper discusses a new approach to model the alumina distribution behavior in an electrolysis cell by dividing the electrolytic bath into non-homogenous concentration zones using discrete elements. The different mechanisms related to the alumina distribution are discussed in detail. Moreover, with a detailed electrical model, it is possible to calculate the current distribution among the different anodic assemblies. With this information, the model can evaluate if low-voltage emissions are likely to be present under the simulated conditions. Using the simulator will help the understanding of the role of the alumina distribution which, in turn, will improve the cell energy consumption and stability while reducing the occurrence of high- and low-voltage anode effects.

  13. Low-voltage organic field-effect transistors based on novel high-κ organometallic lanthanide complex for gate insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qi; Li, Yi; Zhang, Yang; Song, You, E-mail: wangxzh@nju.edu.cn, E-mail: yli@nju.edu.cn, E-mail: yousong@nju.edu.cn; Wang, Xizhang, E-mail: wangxzh@nju.edu.cn, E-mail: yli@nju.edu.cn, E-mail: yousong@nju.edu.cn; Hu, Zheng [Key Laboratory of Mesoscopic Chemistry of MOE, Jiangsu Provincial Lab for Nanotechnology, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China. High-Tech Research Institute of Nanjing University (Suzhou), Suzhou 215123 (China); Sun, Huabin; Li, Yun, E-mail: wangxzh@nju.edu.cn, E-mail: yli@nju.edu.cn, E-mail: yousong@nju.edu.cn; Shi, Yi [School of Electronic Science and Engineering and Jiangsu Provincial Key Laboratory of Photonic and Electronic Materials, Nanjing University, Nanjing 210093 (China)

    2014-08-15

    A novel high-κ organometallic lanthanide complex, Eu(tta){sub 3}L (tta=2-thenoyltrifluoroacetonate, L = 4,5-pinene bipyridine), is used as gate insulating material to fabricate low-voltage pentacene field-effect transistors (FETs). The optimized gate insulator exhibits the excellent properties such as low leakage current density, low surface roughness, and high dielectric constant. When operated under a low voltage of −5 V, the pentacene FET devices show the attractive electrical performance, e.g. carrier mobility (μ{sub FET}) of 0.17 cm{sup 2} V{sup −1} s{sup −1}, threshold voltage (V{sub th}) of −0.9 V, on/off current ratio of 5 × 10{sup 3}, and subthreshold slope (SS) of 1.0 V dec{sup −1}, which is much better than that of devices obtained on conventional 300 nm SiO{sub 2} substrate (0.13 cm{sup 2} V{sup −1} s{sup −1}, −7.3 V and 3.1 V dec{sup −1} for μ{sub FET}, V{sub th} and SS value when operated at −30 V). These results indicate that this kind of high-κ organometallic lanthanide complex becomes a promising candidate as gate insulator for low-voltage organic FETs.

  14. Low-voltage organic field-effect transistors based on novel high-κ organometallic lanthanide complex for gate insulating materials

    Directory of Open Access Journals (Sweden)

    Qi Liu

    2014-08-01

    Full Text Available A novel high-κ organometallic lanthanide complex, Eu(tta3L (tta=2-thenoyltrifluoroacetonate, L = 4,5-pinene bipyridine, is used as gate insulating material to fabricate low-voltage pentacene field-effect transistors (FETs. The optimized gate insulator exhibits the excellent properties such as low leakage current density, low surface roughness, and high dielectric constant. When operated under a low voltage of −5 V, the pentacene FET devices show the attractive electrical performance, e.g. carrier mobility (μFET of 0.17 cm2 V−1 s−1, threshold voltage (Vth of −0.9 V, on/off current ratio of 5 × 103, and subthreshold slope (SS of 1.0 V dec−1, which is much better than that of devices obtained on conventional 300 nm SiO2 substrate (0.13 cm2 V−1 s−1, −7.3 V and 3.1 V dec−1 for μFET, Vth and SS value when operated at −30 V. These results indicate that this kind of high-κ organometallic lanthanide complex becomes a promising candidate as gate insulator for low-voltage organic FETs.

  15. Enhanced emission of encaged-OH--free Ca12(1-x)Sr12xAl14O33:0.1%Gd3+ conductive phosphors via tuning the encaged-electron concentration for low-voltage FEDs.

    Science.gov (United States)

    Zhang, Meng; Liu, Yuxue; Yang, Jian; Zhu, Hancheng; Yan, Duanting; Zhang, Xinyang; Liu, Chunguang; Xu, Changshan; Zhang, Hong

    2017-05-24

    Encaged-OH - -free Ca 12(1-x) Sr 12x Al 14 O 33 :0.1%Gd 3+ conductive phosphors were prepared through a melt-solidification process in combination with a subsequent heat treatment. Absorption spectra showed that the maximum encaged-electron concentration was increased to 1.08 × 10 21 cm -3 through optimizing the doping amount of Sr 2+ (x = 0.005). Meanwhile, FTIR and Raman spectra indicated that pure Ca 11.94 Sr 0.06 Al 14 O 33 :0.1%Gd 3+ conductive phosphor without encaged OH - and C 2 2- anions was acquired. For the conductive powders heat-treated in air for different times, the encaged-electron concentrations were tuned from 1.02 × 10 21 to 8.3 × 10 20 cm -3 . ESR, photoluminescence, and luminescence kinetics analyses indicated that the emission at 312 nm mainly originated from Gd 3+ ions surrounded by encaged O 2- anions, while Gd 3+ ions surrounded by encaged electrons had a negative contribution to the UV emission due to the existence of an energy transfer process. Under low-voltage electron-beam excitation (3 kV), enhanced cathodoluminescence (CL) of the conductive phosphors could be achieved by tuning the encaged-electron concentrations. In particular, for the encaged-OH - -free conductive phosphor, the emission intensity of the CL was about one order of magnitude higher than that of the conductive phosphor containing encaged OH - anions. Our results suggested that the encaged-OH - -free conductive phosphors have potential application in low-voltage FEDs.

  16. Laser damage resistance of hafnia thin films deposited by electron beam deposition, reactive low voltage ion plating, and dual ion beam sputtering

    International Nuclear Information System (INIS)

    Gallais, Laurent; Capoulade, Jeremie; Natoli, Jean-Yves; Commandre, Mireille; Cathelinaud, Michel; Koc, Cian; Lequime, Michel

    2008-01-01

    A comparative study is made of the laser damage resistance of hafnia coatings deposited on fused silica substrates with different technologies: electron beam deposition (from Hf or HfO2 starting material), reactive low voltage ion plating, and dual ion beam sputtering.The laser damage thresholds of these coatings are determined at 1064 and 355 nm using a nanosecond pulsed YAG laser and a one-on-one test procedure. The results are associated with a complete characterization of the samples: refractive index n measured by spectrophotometry, extinction coefficient k measured by photothermal deflection, and roughness measured by atomic force microscopy

  17. Low-voltage organic field effect transistors with a 2-tridecyl[1]benzothieno[3,2-b][1]benzothiophene semiconductor layer.

    Science.gov (United States)

    Amin, Atefeh Y; Khassanov, Artoem; Reuter, Knud; Meyer-Friedrichsen, Timo; Halik, Marcus

    2012-10-10

    An asymmetric n-alkyl substitution pattern was realized in 2-tridecyl[1]benzothieno[3,2-b][1]benzothiophene (C(13)-BTBT) in order to improve the charge transport properties in organic thin-film transistors. We obtained large hole mobilities up to 17.2 cm(2)/(V·s) in low-voltage operating devices. The large mobility is related to densely packed layers of the BTBT π-systems at the channel interface dedicated to the substitution motif and confirmed by X-ray reflectivity measurements. The devices exhibit promising stability in continuous operation for several hours in ambient air.

  18. Integrating Multi-Domain Distributed Energy Systems with Electric Vehicle PQ Flexibility: Optimal Design and Operation Scheduling for Sustainable Low-Voltage Distribution Grids

    DEFF Research Database (Denmark)

    Morvaj, Boran; Knezovic, Katarina; Evins, Ralph

    2016-01-01

    on the grid operation, in addition to coordinated charging, is analysed. Results showed that when the system can be optimally designed, emissions decrease by 64% and additionally 32% with proactive EV integration, whereas EV reactive power control enables integration of larger EV amounts and provides...... in the stable operation. The model was applied to a real low-voltage Danish distribution grid where measurement data is available on hourly basis in order to determine EV flexibility impacts on carbon emissions, as well as the benefits of optimal DES design. The influence of EV reactive power control...

  19. A low-voltage flash memory cell utilizing the gate-injection program/erase method with a recessed channel structure

    International Nuclear Information System (INIS)

    Wu Dake; Huang Ru; Wang Pengfei; Tang Poren; Wang Yangyuan

    2008-01-01

    In this paper, a low-voltage recessed channel SONOS flash memory using the gate-injection program/erase method is proposed and investigated for NAND application. It is shown that the proposed flash memory can achieve 8 V lower programming voltage compared with planar flash memory, due to the effective capacitance coupling and the electric-field enhancement by combining the recessed channel structure and the gate-injection program/erase method. In addition, more than 30% larger threshold voltage window and improved short channel effects can be obtained in the proposed flash memory

  20. High-conductance low-voltage organic thin film transistor with locally rearranged poly(3-hexylthiophene) domain by current annealing on plastic substrate

    Science.gov (United States)

    Pei, Zingway; Tsai, Hsing-Wang; Lai, Hsin-Cheng

    2016-02-01

    The organic material based thin film transistors (TFTs) are attractive for flexible optoelectronics applications due to the ability of lager area fabrication by solution and low temperature process on plastic substrate. Recently, the research of organic TFT focus on low operation voltage and high output current to achieve a low power organic logic circuit for optoelectronic device,such as e-paper or OLED displayer. To obtain low voltage and high output current, high gate capacitance and high channel mobility are key factors. The well-arranged polymer chain by a high temperature postannealing, leading enhancement conductivity of polymer film was a general method. However, the thermal annealing applying heat for all device on the substrate and may not applicable to plastic substrate. Therefore, in this work, the low operation voltage and high output current of polymer TFTs was demonstrated by locally electrical bias annealing. The poly(styrene-comethyl methacrylate) (PS-r-PMMA) with ultra-thin thickness is used as gate dielectric that the thickness is controlled by thermal treatment after spin coated on organic electrode. In electrical bias-annealing process, the PS-r- PMMA is acted a heating layer. After electrical bias-annealing, the polymer TFTs obtain high channel mobility at low voltage that lead high output current by a locally annealing of P3HT film. In the future, the locally electrical biasannealing method could be applied on plastic substrate for flexible optoelectronic application.

  1. 18/20 T high magnetic field scanning tunneling microscope with fully low voltage operability, high current resolution, and large scale searching ability.

    Science.gov (United States)

    Li, Quanfeng; Wang, Qi; Hou, Yubin; Lu, Qingyou

    2012-04-01

    We present a home-built 18/20 T high magnetic field scanning tunneling microscope (STM) featuring fully low voltage (lower than ±15 V) operability in low temperatures, large scale searching ability, and 20 fA high current resolution (measured by using a 100 GOhm dummy resistor to replace the tip-sample junction) with a bandwidth of 3.03 kHz. To accomplish low voltage operation which is important in achieving high precision, low noise, and low interference with the strong magnetic field, the coarse approach is implemented with an inertial slider driven by the lateral bending of a piezoelectric scanner tube (PST) whose inner electrode is axially split into two for enhanced bending per volt. The PST can also drive the same sliding piece to inertial slide in the other bending direction (along the sample surface) of the PST, which realizes the large area searching ability. The STM head is housed in a three segment tubular chamber, which is detachable near the STM head for the convenience of sample and tip changes. Atomic resolution images of a graphite sample taken under 17.6 T and 18.0001 T are presented to show its performance. © 2012 American Institute of Physics

  2. Conventional P-ω/Q-V Droop Control in Highly Resistive Line of Low-Voltage Converter-Based AC Microgrid

    Directory of Open Access Journals (Sweden)

    Xiaochao Hou

    2016-11-01

    Full Text Available In low-voltage converter-based alternating current (AC microgrids with resistive distribution lines, the P-V droop with Q-f boost (VPD/FQB is the most common method for load sharing. However, it cannot achieve the active power sharing proportionally. To overcome this drawback, the conventional P-ω/Q-V droop control is adopted in the low-voltage AC microgrid. As a result, the active power sharing among the distributed generators (DGs is easily obtained without communication. More importantly, this study clears up the previous misunderstanding that conventional P-ω/Q-V droop control is only applicable to microgrids with highly inductive lines, and lays a foundation for the application of conventional droop control under different line impedances. Moreover, in order to guarantee the accurate reactive power sharing, a guide for designing Q-V droop gains is given, and virtual resistance is adopted to shape the desired output impedance. Finally, the effects of power sharing and transient response are verified through simulations and experiments in converter-based AC Microgrid.

  3. Low-voltage operating flexible ferroelectric organic field-effect transistor nonvolatile memory with a vertical phase separation P(VDF-TrFE-CTFE)/PS dielectric

    Science.gov (United States)

    Xu, Meili; Xiang, Lanyi; Xu, Ting; Wang, Wei; Xie, Wenfa; Zhou, Dayu

    2017-10-01

    Future flexible electronic systems require memory devices combining low-power operation and mechanical bendability. However, high programming/erasing voltages, which are universally needed to switch the storage states in previously reported ferroelectric organic field-effect transistor (Fe-OFET) nonvolatile memories (NVMs), severely prevent their practical applications. In this work, we develop a route to achieve a low-voltage operating flexible Fe-OFET NVM. Utilizing vertical phase separation, an ultrathin self-organized poly(styrene) (PS) buffering layer covers the surface of the ferroelectric polymer layer by one-step spin-coating from their blending solution. The ferroelectric polymer with a low coercive field contributes to low-voltage operation in the Fe-OFET NVM. The polymer PS contributes to the improvement of mobility, attributing to screening the charge scattering and decreasing the surface roughness. As a result, a high performance flexible Fe-OFET NVM is achieved at the low P/E voltages of ±10 V, with a mobility larger than 0.2 cm2 V-1 s-1, a reliable P/E endurance over 150 cycles, stable data storage retention capability over 104 s, and excellent mechanical bending durability with a slight performance degradation after 1000 repetitive tensile bending cycles at a curvature radius of 5.5 mm.

  4. Improvement in interfacial characteristics of low-voltage carbon nanotube thin-film transistors with solution-processed boron nitride thin films

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jun-Young; Ha, Tae-Jun, E-mail: taejunha0604@gmail.com

    2017-08-15

    Highlights: • We demonstrate the potential of solution-processed boron nitride (BN) thin films for nanoelectronics. • Improved interfacial characteristics reduced the leakage current by three orders of magnitude. • The BN encapsulation improves all the device key metrics of low-voltage SWCNT-TFTs. • Such improvements were achieved by reduced interaction of interfacial localized states. - Abstract: In this article, we demonstrate the potential of solution-processed boron nitride (BN) thin films for high performance single-walled carbon nanotube thin-film transistors (SWCNT-TFTs) with low-voltage operation. The use of BN thin films between solution-processed high-k dielectric layers improved the interfacial characteristics of metal-insulator-metal devices, thereby reducing the current density by three orders of magnitude. We also investigated the origin of improved device performance in SWCNT-TFTs by employing solution-processed BN thin films as an encapsulation layer. The BN encapsulation layer improves the electrical characteristics of SWCNT-TFTs, which includes the device key metrics of linear field-effect mobility, sub-threshold swing, and threshold voltage as well as the long-term stability against the aging effect in air. Such improvements can be achieved by reduced interaction of interfacial localized states with charge carriers. We believe that this work can open up a promising route to demonstrate the potential of solution-processed BN thin films on nanoelectronics.

  5. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013)

    Science.gov (United States)

    Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677

  6. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013

    Directory of Open Access Journals (Sweden)

    Pedro M. Lara-Santillán

    2014-01-01

    Full Text Available This paper presents a comparative study of the electricity consumption (EC in an urban low-voltage substation before and during the economic crisis (2008–2013. This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012 with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis. These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.. The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.

  7. Low-Voltage 96 dB Snapshot CMOS Image Sensor with 4.5 nW Power Dissipation per Pixel

    Directory of Open Access Journals (Sweden)

    Orly Yadid-Pecht

    2012-07-01

    Full Text Available Modern “smart” CMOS sensors have penetrated into various applications, such as surveillance systems, bio-medical applications, digital cameras, cellular phones and many others. Reducing the power of these sensors continuously challenges designers. In this paper, a low power global shutter CMOS image sensor with Wide Dynamic Range (WDR ability is presented. This sensor features several power reduction techniques, including a dual voltage supply, a selective power down, transistors with different threshold voltages, a non-rationed logic, and a low voltage static memory. A combination of all these approaches has enabled the design of the low voltage “smart” image sensor, which is capable of reaching a remarkable dynamic range, while consuming very low power. The proposed power-saving solutions have allowed the maintenance of the standard architecture of the sensor, reducing both the time and the cost of the design. In order to maintain the image quality, a relation between the sensor performance and power has been analyzed and a mathematical model, describing the sensor Signal to Noise Ratio (SNR and Dynamic Range (DR as a function of the power supplies, is proposed. The described sensor was implemented in a 0.18 um CMOS process and successfully tested in the laboratory. An SNR of 48 dB and DR of 96 dB were achieved with a power dissipation of 4.5 nW per pixel.

  8. Synthesis of Pt nanoparticles as catalysts of oxygen reduction with microbubble-assisted low-voltage and low-frequency solution plasma processing

    Science.gov (United States)

    Horiguchi, Genki; Chikaoka, Yu; Shiroishi, Hidenobu; Kosaka, Shinpei; Saito, Morihiro; Kameta, Naohiro; Matsuda, Naoki

    2018-04-01

    In the preparation of metallic nanoparticles by conventional solution plasma (SP) techniques, unstable plasma emission becomes an issue when the voltage and frequency of the waves applied between two electrodes placed in solution are lowered to avoid the boiling of the solution. In this study, we confirm that, in the presence of microbubbles, plasma is generated stably at low voltage (440 V) and low frequency (50-100 Hz) and small-size (≤10 nm) Pt nanoparticles (PtNPs) are synthesized in succession using a flow cell. The smallest PtNPs, ∼3.3 nm in diameter, are obtained using half-wave rectification, a tungsten wire anode, and a platinum wire cathode. The PtNPs are characterized by X-ray diffraction, X-ray photoelectron spectroscopy, transmission electron microscopy, and thermogravimeter-differential thermal analysis. The oxygen reduction reaction (ORR) is investigated in 0.1 M HClO4 solution on carbon-supported PtNPs using a rotating ring-disk electrode. The catalytic activities per initial electrochemical active surface area of the carbon-supported PtNPs synthesized employing the low-voltage, low-frequency (LVLF)-SP technique is higher than that of the commercially available 20 wt% Pt on Vulcan XC-72R. These results indicate that the LVLF-SP technique is a promising approach to producing carbon-supported PtNPs that catalyze ORR with low energy consumption.

  9. Low-voltage organic thin film transistors (OTFTs) using crosslinked polyvinyl alcohol (PVA)/neodymium oxide (Nd2O3) bilayer gate dielectrics

    Science.gov (United States)

    Khound, Sagarika; Sarma, Ranjit

    2018-01-01

    We have reported here on the design, processing and dielectric properties of pentacene-based organic thin film transitors (OTFTs) with a bilayer gate dilectrics of crosslinked PVA/Nd2O3 which enables low-voltage organic thin film operations. The dielectric characteristics of PVA/Nd2O3 bilayer films are studied by capacitance-voltage ( C- V) and current-voltage ( I- V) curves in the metal-insulator-metal (MIM) structure. We have analysed the output electrical responses and transfer characteristics of the OTFT devices to determine their performance of OTFT parameters. The mobility of 0.94 cm2/Vs, the threshold voltage of - 2.8 V, the current on-off ratio of 6.2 × 105, the subthreshold slope of 0.61 V/decade are evaluated. Low leakage current of the device is observed from current density-electric field ( J- E) curve. The structure and the morphology of the device are studied using X-ray diffraction (XRD) and atomic force microscope (AFM), respectively. The study demonstrates an effective way to realize low-voltage, high-performance OTFTs at low cost.

  10. Low-voltage 96 dB snapshot CMOS image sensor with 4.5 nW power dissipation per pixel.

    Science.gov (United States)

    Spivak, Arthur; Teman, Adam; Belenky, Alexander; Yadid-Pecht, Orly; Fish, Alexander

    2012-01-01

    Modern "smart" CMOS sensors have penetrated into various applications, such as surveillance systems, bio-medical applications, digital cameras, cellular phones and many others. Reducing the power of these sensors continuously challenges designers. In this paper, a low power global shutter CMOS image sensor with Wide Dynamic Range (WDR) ability is presented. This sensor features several power reduction techniques, including a dual voltage supply, a selective power down, transistors with different threshold voltages, a non-rationed logic, and a low voltage static memory. A combination of all these approaches has enabled the design of the low voltage "smart" image sensor, which is capable of reaching a remarkable dynamic range, while consuming very low power. The proposed power-saving solutions have allowed the maintenance of the standard architecture of the sensor, reducing both the time and the cost of the design. In order to maintain the image quality, a relation between the sensor performance and power has been analyzed and a mathematical model, describing the sensor Signal to Noise Ratio (SNR) and Dynamic Range (DR) as a function of the power supplies, is proposed. The described sensor was implemented in a 0.18 um CMOS process and successfully tested in the laboratory. An SNR of 48 dB and DR of 96 dB were achieved with a power dissipation of 4.5 nW per pixel.

  11. Low voltage stress-induced leakage current and traps in ultrathin oxide (1.2 2.5 nm) after constant voltage stresses

    Science.gov (United States)

    Petit, C.; Zander, D.

    2007-10-01

    It has been shown that the low voltage gate current in ultrathin oxide metal-oxide-semiconductor devices is very sensitive to electrical stresses. Therefore, it can be used as a reliability monitor when the oxide thickness becomes too small for traditional electrical measurements to be used. In this work, we present a study on n-MOSCAP devices at negative gate bias in the direct tunneling (DT) regime. If the low voltage stress-induced leakage current (LVSILC) depends strongly on the low sense voltages, it also depends strongly on the stress voltage magnitude. We show that two LVSILC peaks appear as a function of the sense voltage in the LVSILC region and that their magnitude, one compared to the other, depends strongly on the stress voltage magnitude. One is larger than the other at low stress voltage and smaller at high stress voltage. From our experimental results, different conduction mechanisms are analyzed. To explain LVSILC variations, we propose a model of the conduction through the ultrathin gate oxide based on two distinctly different trap-assisted tunneling mechanisms: inelastic of gate electron (INE) and trap-assisted electron (ETAT).

  12. Controlled Operation of the Islanded Portion of the International Council on Large Electric Systems (CIGRE) Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak, Claus Leth; Ali, Ehsan

    2017-01-01

    In islanding, a portion of the power network, comprised of the loads and distributed generation (DG) units, is isolated from the rest of the power grid and forms a micro grid (MG). In this condition, it becomes essential for the islanded MG to operate in a stable and controlled manner by providing...... ancillary services. When the MG is cut off from the main grid, the islanding must be detected by the DG units. In this condition it is essential that one of the controllers should be switched to the voltage-frequency (VF) control mode. In islanding, the network loses it slack reference and this reference...

  13. Low-voltage electrically-enhanced microextraction as a novel technique for simultaneous extraction of acidic and basic drugs from biological fluids.

    Science.gov (United States)

    Seidi, Shahram; Yamini, Yadollah; Rezazadeh, Maryam; Esrafili, Ali

    2012-06-22

    In the present work, for the first time a new set-up was presented for simultaneous extraction of acidic and basic drugs using a recent novel electrically-enhanced microextraction technique, termed electromembrane extraction at low voltages followed by high performance liquid chromatography with ultraviolet detection. Nalmefene (NAL) as a basic drug and diclofenac (DIC) as an acidic drug were extracted from 24 mL aqueous sample solutions at neutral pH into 10 μL of each acidified (HCl 50 mM) and basic (NaOH 50 mM) acceptor solution, respectively. Supported liquid membranes including 2-nitrophenyl octyl ether containing 5% di-(2-ethylhexyl) phosphate and 1-octanol were used to ensure efficient extraction of NAL and DIC, respectively. Low voltage of 40 V was applied over the SLMs during 14 min extraction time. The influences of fundamental parameters affecting the transport of target drugs were optimized using experimental design. Under optimal conditions, NAL and DIC were extracted with extraction recoveries of 12.5 and 14.6, respectively, which corresponded to preconcentration factors of 300 and 350, respectively. The proposed technique provided good linearity with correlation coefficient values higher than 0.9956 over a concentration range of 8-500 μg L⁻¹ and 12-500 μg L⁻¹ for NAL and DIC, respectively. Limits of detection and quantifications, and intra-day precisions (n=3) were less than 4 μg L⁻¹, 12 μg L⁻¹, and 10.1%, respectively. Extraction and determination of NAL and DIC in human urine samples were successfully performed. In light of the data obtained in the present work, this new set-up for EME with low voltages has a future potential as a simple, selective, and fast sample preparation technique for simultaneous extraction and determination of acidic and basic drugs in different complicated matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Optimal placement, sizing, and daily charge/discharge of battery energy storage in low voltage distribution network with high photovoltaic penetration

    DEFF Research Database (Denmark)

    Jannesar, Mohammad Rasol; Sedighi, Alireza; Savaghebi, Mehdi

    2018-01-01

    when photovoltaic penetration is increased in low voltage distribution network. Local battery energy storage system can mitigate these disadvantages and as a result, improve the system operation. For this purpose, battery energy storage system is charged when production of photovoltaic is more than...... consumers’ demands and discharged when consumers’ demands are increased. Since the price of battery energy storage system is high, economic, environmental, and technical objectives should be considered together for its placement and sizing. In this paper, optimal placement, sizing, and daily (24 h) charge......Proper installation of rooftop photovoltaic generation in distribution networks can improve voltage profile, reduce energy losses, and enhance the reliability. But, on the other hand, some problems regarding harmonic distortion, voltage magnitude, reverse power flow, and energy losses can arise...

  15. Low Voltage Ride-Through of Two-Stage Grid-Connected Photovoltaic Systems Through the Inherent Linear Power-Voltage Characteristic

    DEFF Research Database (Denmark)

    Yang, Yongheng; Sangwongwanich, Ariya; Liu, Hongpeng

    2017-01-01

    In this paper, a cost-effective control scheme for two-stage grid-connected PhotoVoltaic (PV) systems in Low Voltage Ride-Through (LVRT) operation is proposed. In the case of LVRT, the active power injection by PV panels should be limited to prevent from inverter over-current and also energy...... aggregation at the dc-link, which will challenge the dc-link capacitor lifetime if remains uncontrolled. At the same time, reactive currents should be injected upon any demand imposed by the system operators. In the proposed scheme, the two objectives can be feasibly achieved. The active power is regulated...... point tracking controller without significant hardware or software modifications. In this way, the PV system will not operate at the maximum power point, whereas the inverter will not face any over-current challenge but can provide reactive power support in response to the grid voltage fault...

  16. Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive Microgrids by Using Negative-Sequence Droop Control

    DEFF Research Database (Denmark)

    Zhao, Xin; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    of the utility grid during grid faults. In this paper, a LVRT control strategy based on positive/negative sequence droop control is proposed for grid-interactive MGs to ride-through voltage sags with not only inductive/resistive, but also complex line impedance. By using the proposed control strategy, MGs can......Due to the increasing penetration level of microgrids (MGs), it becomes a critical issue for MGs to help sustaining power system stability. Therefore, ancillary services, such as the low-voltage ride-through (LVRT) capability should be incorporated in MGs in order to guarantee stable operation...... support the grid voltage, make profits, and also ride-through the voltage dip during the whole fault period. A two layer hierarchical control strategy is proposed in this paper. The primary controller consists of voltage and current inner loops, a conventional droop control and a virtual impedance loop...

  17. An analysis of the technical exigencies and CE marking relative to low voltage (less than 5 kW) photovoltaic inverters marketed in Spain

    International Nuclear Information System (INIS)

    Salas, V.; Olias, E.

    2009-01-01

    The objective of this article is to analyse the standards relative to technical exigencies and CE marking that correspond to photovoltaic inverters of low voltage (less than 5 kW) as marketed in Spain. For this study, around 400 different models of inverters from the European market were compiled. Twelve of them, 50 Hz single phase, were chosen, made up of different brands and options of transformer below 5 kW. For these inverters, regulations for each model were examined according to their data sheet specifications, manual and EC Declarations of Conformity. Heterogeneity in compliance to the standards was found. In addition, in view of results obtained it is possible to conclude that it would be wise to establish a common set of standards for every country in the world (or at least a common European normalization) according to PV grid inverters. It would enable all grid inverters to be commercialised in compliance with the same standards everywhere. (author)

  18. Low-voltage ride-through of a droop-based three-phase four-wire grid-connected microgrid

    DEFF Research Database (Denmark)

    Sadeghkhani, Iman; Golshan, Mohamad Esmail Hamedani; Mehrizi-Sani, Ali

    2018-01-01

    system operations during abnormal grid conditions. The objective of this paper is to propose an LVRT scheme that improves the power quality of the entire microgrid. The developed method is implemented as the controller of the interface voltage-sourced converter (VSC) of a distributed energy resource...... control of each phase and does not require calculation of symmetrical components. Moreover, it can be employed in the VSC control systems with various reference frames and is effective for droop-based grid-connected microgrids with both single-phase and three-phase four-wire configurations. The proposed......The ability of riding through the grid disturbances can increase the integration of microgrids into the distribution system. Consequently, a grid-connected microgrid should provide ancillary services such as low voltage ride-through (LVRT) capability and reactive power support to sustain the power...

  19. Smart Solar Grid. Integration of high penetration of photovoltaic in municipal low voltage distribution grids; Smart Solar Grid. Integration hoher Anteile von Photovoltaik in kommunalen Niederspannungsverteilnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Ruf, Holger; Heilscher, Gerd [Hochschule Ulm (Germany); Meier, Florian [SWU Netze GmbH, Ulm (Germany)

    2012-07-01

    The high rate of decentralized generation in low voltage grids especially photovoltaic (PV) put the distribution grid operators to new challenges. Grid operation and grid planning have to respect the volatility and dynamic of decentralized generation now and in the future and adapt their previous proceedings. In the frame of the project Smart Solar Grid was a test site defined in the grid area of the DSO Stadtwerke Ulm/Neu-Ulm GmbH (SWU) to analyze the impact of the PV rise and possible solutions for the grid planning in the future. The first analysis based upon secondly measurements of the first test site. From this were statistical evaluation of the load flows and power variations done. Furthermore were the roof potential analysis results of the test site validated. These data are the base for the development of a forecast system for grid condition parameter. (orig.)

  20. An improved low-voltage ride-through performance of DFIG based wind plant using stator dynamic composite fault current limiter.

    Science.gov (United States)

    Gayen, P K; Chatterjee, D; Goswami, S K

    2016-05-01

    In this paper, an enhanced low-voltage ride-through (LVRT) performance of a grid connected doubly fed induction generator (DFIG) has been presented with the usage of stator dynamic composite fault current limiter (SDCFCL). This protection circuit comprises of a suitable series resistor-inductor combination and parallel bidirectional semiconductor switch. The SDCFCL facilitates double benefits such as reduction of rotor induced open circuit voltage due to increased value of stator total inductance and concurrent increase of rotor impedance. Both effects will limit rotor circuit over current and over voltage situation more secured way in comparison to the conventional scheme like the dynamic rotor current limiter (RCL) during any type of fault situation. The proposed concept is validated through the simulation study of the grid integrated 2.0MW DFIG. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Experimental and theoretical studies of a high temperature cesium-barium tacitron, with application to low voltage-high current inversion

    International Nuclear Information System (INIS)

    Murray, C.S.; El-Genk, M.S.

    1994-02-01

    A low voltage/high current switch refer-red as ''Cs-Ba tacitron'' is studied for use as a dc to ac inverter in high temperature and/or ionizing radiation environments. The operational characteristics of the Cs-Ba tacitron as a switch were investigated experimentally in three modes: (a) breakdown mode, (b) I-V mode, and (c) current modulation mode. Operation parameters measured include switching frequencies up to 20 kHz, hold-off voltages up to 200 V, current densities in excess of 15 A/CM 2 , switch power density of 1 kW/cm 2 , and a switching efficiency in excess of 90 % at collector voltages greater than 30 V. Also, if the discharge current is circuit limited to a value below the maximum thermal emission current density, the voltage drop is constant and below 3 V

  2. A high-efficiency low-voltage class-E PA for IoT applications in sub-1 GHz frequency range

    Science.gov (United States)

    Zhou, Chenyi; Lu, Zhenghao; Gu, Jiangmin; Yu, Xiaopeng

    2017-10-01

    We present and propose a complete and iterative integrated-circuit and electro-magnetic (EM) co-design methodology and procedure for a low-voltage sub-1 GHz class-E PA. The presented class-E PA consists of the on-chip power transistor, the on-chip gate driving circuits, the off-chip tunable LC load network and the off-chip LC ladder low pass filter. The design methodology includes an explicit design equation based circuit components values' analysis and numerical derivation, output power targeted transistor size and low pass filter design, and power efficiency oriented design optimization. The proposed design procedure includes the power efficiency oriented LC network tuning, the detailed circuit/EM co-simulation plan on integrated circuit level, package level and PCB level to ensure an accurate simulation to measurement match and first pass design success. The proposed PA is targeted to achieve more than 15 dBm output power delivery and 40% power efficiency at 433 MHz frequency band with 1.5 V low voltage supply. The LC load network is designed to be off-chip for the purpose of easy tuning and optimization. The same circuit can be extended to all sub-1 GHz applications with the same tuning and optimization on the load network at different frequencies. The amplifier is implemented in 0.13 μm CMOS technology with a core area occupation of 400 μm by 300 μm. Measurement results showed that it provided power delivery of 16.42 dBm at antenna with efficiency of 40.6%. A harmonics suppression of 44 dBc is achieved, making it suitable for massive deployment of IoT devices. Project supported by the National Natural Science Foundation of China (No. 61574125) and the Industry Innovation Project of Suzhou City of China (No. SYG201641).

  3. SU-G-TeP3-05: In Vitro Demonstration of Endothelial Dose Enhancement Due to Gold Nanoparticles During Low-Voltage Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yasmin-Karim, S; Makrigiorgos, GM [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Moreau, M; Ngwa, W [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); University of Massachusetts Lowell, Lowell, MA (United States); Kumar, R [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Northeastern University, Boston, MA (United States); Hanlon, J; Arnoldussen, M [Oraya Therapeutics Inc., Newark, CA (United States); Hempstead, J; Celli, J [University of Massachusetts Boston, Boston, MA (United States)

    2016-06-15

    Purpose: Oraya Therapy uses low-voltage, stereotactic, highly targeted X-rays for the treatment of wet age-related macular degeneration (AMD) — offering a new option for patients worldwide. Neovascular endothelial cells play a crucial role in the pathogenesis of this disease. This in-vitro study investigates the potential of gold nanoparticles (GNP) to enhance endothelial cell damage during low-voltage radiotherapy towards potential applications in the treatment of wet-AMD. Methods: Primary human umbilical cord vein endothelium cells (HUVEC) were treated with 1.4 nm sized GNPs for 24 hrs and then irradiated with variable X-ray doses using an Oraya therapy system (100 kVp) or a Small Animal Radiation and Research platform (SARRP) at other beam qualities (up to 220 kVp). Radio-sensitization was assessed by clonogenic assays. Variable concentrations of GNPs (0.05 mg/ml, 0.1 mg/ml, 0.25 mg/ml, 0.5 mg/ml, and 1 mg/ml) where employed. The dose enhancement factor (DEF) was calculated as the ratio of radiation doses required to give the same biological effect (survival factor, SF) with and without GNPs. Results: Preliminary results show DEFs of up to 2.62 for the different combinations of x-ray doses and GNP concentrations and beam qualities. In general the DEF increased with increase in GNP concentration. However, for high doses the effect of GNP becomes less apparent likely due to already high cell kill by the radiation alone. Conclusion: The findings suggest that targeted GNPs can play a significant synergistic role in enhancing stereotactic radiosurgery for wet AMD. The results also provide impetus for ongoing studies to find the optimal synergy between the doses or beam energies and GNPs concentration. This will benefit in-vivo studies towards development of nanoparticle-aided radiotherapy for treatment of wet-AMD and potentially ocular cancers.

  4. ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS

    Directory of Open Access Journals (Sweden)

    V. N. Radkevich

    2014-01-01

    Full Text Available This paper describes an estimation method of decreasing losses of active power in power transformers with voltage 10(6/0,4 kV after installation of devices of reactive power compensation on output side depending on voltage level, connected to capacity devices, taking into account dielectric loss in capacitors. Analysis of functional dependences was carried out. Investigation of function with a help of derivations was carried out. Points of function extremum and also its intervals of rise and fall rates were founded. This paper describes graphic investigation of obtained functional dependence, which is introduced by quartic polynominal. It is established that decreasing of losses of active power depends on technical parameters and load factor of transformer, coefficient of loading power of electricity consumers, voltage value connected to capacitor unit.Using obtained functional dependences, calculations for the main size-types of power transformers with voltage 10(6/0,4 kV serie ТМГ 11 and ТМГ12 were done. It is established that depending on technical characteristics of certain transformer, coefficient of its loading and power, there is a definite value of deviation of real voltage value from working voltage of capacitor installation when it will be observed positive technical and economical effect from installed capacitor battery unit. For taken value of loading coefficient and transformer’s power the maximum decrease of losses of active power takes place under voltage directed to capacitor unit, which is lower then nominal value. For all taken size-types of power transformers the argument of investigating function for its maximal value is out of standard permissible of voltage deviations from nominal value.These functional dependents can be used for preliminary calculations, which are needed for making decision on compensation of reactive power in electric power supply systems of industrial objects. Their consideration allows more

  5. Power grid, mains filtering and power line communications ... a root cause for incompatibilities

    NARCIS (Netherlands)

    Coenen, Mart

    2013-01-01

    The power grid is intentionally meant to distribute electrical energy at the mains frequency, as produced by the electricity generating plants, towards the end-users. The three-phase low-voltage distribution network can be utilized more efficiently when a power factor of 1 is achieved and no

  6. Power Snapshot Analysis (PSSA) of low voltage grids by means of smart meters; Power Snapshot Analyse (PSSA) von Niederspannungsnetzen durch den Einsatz von intelligenten Elektrizitaetszaehlern ('Smart Meters')

    Energy Technology Data Exchange (ETDEWEB)

    Ritz, Richard; Bauer, Wolfgang [Siemens AG Oesterreich, Wien (Austria); Stifter, Matthias [Austrian Institute of Technology (AIT), Wien (Austria); Abart, Andreas [Energie AG Oberoesterreich, Linz (Austria); Pointner, Rudolf [Salzburg Netz, Salzburg (Austria); Taus, Hans [Wien Energie Stromnetz GmbH, Wien (Austria)

    2012-07-01

    Besides the actual metering tasks, intelligent electricity meters (''smart meters'') can be used for the economic acquisition of distribution grid parameters. This results in more knowledge about the actual situation in the low-voltage distribution grid and allows new ways to analyze electrical low-voltage grids. This is the base for a more efficient utilization of the grid's infrastructure, especially in case of the increasing decentralized energy generation and E-mobility. (orig.)

  7. Bidirectional energy management of loads and decentralized generators in the low voltage grid. Field tests and applications; Bidirektionales Energiemanagement fuer Lasten und dezentrale Erzeuger im Niederspannungsnetz. Feldtest und Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Bendel, C.; Dallinger, D.; Nestle, D.; Ringelstein, J. [ISET e.V., Kassel (Germany)

    2008-07-01

    In the context of growing installation of decentralized and fluctuating generation in the low voltage grid, energy management in this grid level becomes more and more important. In the research project DINAR, an approach therefor was developed and implemented. This approach combines automatic management of loads and decentralized generators by decentral decision, customer information and interaction, meter reading and low voltage grid measurement. This paper covers the developed concept and results from the field test in project DINAR as well as currently ongoing research activity on possible applications. (orig.)

  8. Low voltage electron beam accelerators

    International Nuclear Information System (INIS)

    Ochi, Masafumi

    2003-01-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  9. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  10. Main Memory

    NARCIS (Netherlands)

    P.A. Boncz (Peter); L. Liu (Lei); M. Tamer Özsu

    2008-01-01

    htmlabstractPrimary storage, presently known as main memory, is the largest memory directly accessible to the CPU in the prevalent Von Neumann model and stores both data and instructions (program code). The CPU continuously reads instructions stored there and executes them. It is also called Random

  11. Interface engineering in high-performance low-voltage organic thin-film transistors based on 2,7-dialkyl-[1]benzothieno[3,2-b][1]benzothiophenes.

    Science.gov (United States)

    Amin, Atefeh Y; Reuter, Knud; Meyer-Friedrichsen, Timo; Halik, Marcus

    2011-12-20

    We investigated two different (2,7-dialkyl-[1]benzothieno[3,2-b][1]benzothiophenes; C(n)-BTBT-C(n), where n = 12 or 13) semiconductors in low-voltage operating thin-film transistors. By choosing functional molecules in nanoscaled hybrid dielectric layers, we were able to tune the surface energy and improve device characteristics, such as leakage current and hysteresis. The dipolar nature of the self-assembled molecules led to a shift in the threshold voltage. All devices exhibited high charge carrier mobilities of 0.6-7.0 cm(2) V(-1) s(-1). The thin-film morphology of BTBT was studied by means of atomic force microscopy (AFM), presented a dependency upon the surface energy of the self-assembled monolayer (SAM) hybrid dielectrics but not upon the device performance. The use of C(13)-BTBT-C(13) on hybrid dielectrics of AlO(x) and a F(15)C(18)-phosphonic acid monolayer led to devices with a hole mobility of 1.9 cm(2) V(-1) s(-1) at 3 V, on/off ratio of 10(5), small device-device variation of mobility, and a threshold voltage of only -0.9 V, thus providing excellent characteristics for further integration. © 2011 American Chemical Society

  12. High Voltage Distribution System (HVDS) as a better system compared to Low Voltage Distribution System (LVDS) applied at Medan city power network

    Science.gov (United States)

    Dinzi, R.; Hamonangan, TS; Fahmi, F.

    2018-02-01

    In the current distribution system, a large-capacity distribution transformer supplies loads to remote locations. The use of 220/380 V network is nowadays less common compared to 20 kV network. This results in losses due to the non-optimal distribution transformer, which neglected the load location, poor consumer profile, and large power losses along the carrier. This paper discusses how high voltage distribution systems (HVDS) can be a better system used in distribution networks than the currently used distribution system (Low Voltage Distribution System, LVDS). The proposed change of the system into the new configuration is done by replacing a large-capacity distribution transformer with some smaller-capacity distribution transformers and installed them in positions that closest to the load. The use of high voltage distribution systems will result in better voltage profiles and fewer power losses. From the non-technical side, the annual savings and payback periods on high voltage distribution systems will also be the advantage.

  13. Polymer/metal oxide hybrid dielectrics for low voltage field-effect transistors with solution-processed, high-mobility semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Held, Martin; Schießl, Stefan P.; Gannott, Florentina [Department of Materials Science and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen D-91058 (Germany); Institute for Physical Chemistry, Universität Heidelberg, Heidelberg D-69120 (Germany); Miehler, Dominik [Department of Materials Science and Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen D-91058 (Germany); Zaumseil, Jana, E-mail: zaumseil@uni-heidelberg.de [Institute for Physical Chemistry, Universität Heidelberg, Heidelberg D-69120 (Germany)

    2015-08-24

    Transistors for future flexible organic light-emitting diode (OLED) display backplanes should operate at low voltages and be able to sustain high currents over long times without degradation. Hence, high capacitance dielectrics with low surface trap densities are required that are compatible with solution-processable high-mobility semiconductors. Here, we combine poly(methyl methacrylate) (PMMA) and atomic layer deposition hafnium oxide (HfO{sub x}) into a bilayer hybrid dielectric for field-effect transistors with a donor-acceptor polymer (DPPT-TT) or single-walled carbon nanotubes (SWNTs) as the semiconductor and demonstrate substantially improved device performances for both. The ultra-thin PMMA layer ensures a low density of trap states at the semiconductor-dielectric interface while the metal oxide layer provides high capacitance, low gate leakage and superior barrier properties. Transistors with these thin (≤70 nm), high capacitance (100–300 nF/cm{sup 2}) hybrid dielectrics enable low operating voltages (<5 V), balanced charge carrier mobilities and low threshold voltages. Moreover, the hybrid layers substantially improve the bias stress stability of the transistors compared to those with pure PMMA and HfO{sub x} dielectrics.

  14. Significance of the double-layer capacitor effect in polar rubbery dielectrics and exceptionally stable low-voltage high transconductance organic transistors.

    Science.gov (United States)

    Wang, Chao; Lee, Wen-Ya; Kong, Desheng; Pfattner, Raphael; Schweicher, Guillaume; Nakajima, Reina; Lu, Chien; Mei, Jianguo; Lee, Tae Hoon; Wu, Hung-Chin; Lopez, Jeffery; Diao, Ying; Gu, Xiaodan; Himmelberger, Scott; Niu, Weijun; Matthews, James R; He, Mingqian; Salleo, Alberto; Nishi, Yoshio; Bao, Zhenan

    2015-12-14

    Both high gain and transconductance at low operating voltages are essential for practical applications of organic field-effect transistors (OFETs). Here, we describe the significance of the double-layer capacitance effect in polar rubbery dielectrics, even when present in a very low ion concentration and conductivity. We observed that this effect can greatly enhance the OFET transconductance when driven at low voltages. Specifically, when the polar elastomer poly(vinylidene fluoride-co-hexafluoropropylene) (e-PVDF-HFP) was used as the dielectric layer, despite a thickness of several micrometers, we obtained a transconductance per channel width 30 times higher than that measured for the same organic semiconductors fabricated on a semicrystalline PVDF-HFP with a similar thickness. After a series of detailed experimental investigations, we attribute the above observation to the double-layer capacitance effect, even though the ionic conductivity is as low as 10(-10) S/cm. Different from previously reported OFETs with double-layer capacitance effects, our devices showed unprecedented high bias-stress stability in air and even in water.

  15. Comparative Study of Modulation-Based Individual Inverter Techniques for Direct and Inverse by using Star-Connection Induction Motor in Extra Low Voltage Application

    Directory of Open Access Journals (Sweden)

    Ardhia Wishnuprakasa

    2016-12-01

    Full Text Available In this study, the IEEE 519 Standard as a basis benchmarking for voltage (THDV and current (THDI in draft performance. Comparative Study based onthree-techniques of 2-Level Converter (2LC by using a Star-Connection Induction Motor (Y-CIM in ExtraLow Voltage (ELV Configuration.For the detail explanation, a primary inverter as Direct-Inverterby PWMdirect (PWM degreesand asecondary inverter as Inverse-Inverterby PWMinverse(PWM + PI degrees. It tends a modified algorithm,for eachof SPWM in six rules, and FHIPWM in 5th harmonics Injectedin standard modulation as the purpose for the Open-Ends of Pre-Dual Inverter in Decoupled SPWM for twelve rules, and Decoupled FHIPWM in combination of 5th harmonics Injectedin combination of two-standard-modulation. Those techniques are the purpose of two-inverter combination, which namelythe Equal Direct-Inverse (EDI algorithmproduct of prototyping in similarities. The observation is restricted in voltage scope between Simulation by using Power Simulator (PSIMand Application by using Microcontroller ARM STM32F4 Discovery.

  16. Significance of the double-layer capacitor effect in polar rubbery dielectrics and exceptionally stable low-voltage high transconductance organic transistors

    Science.gov (United States)

    Wang, Chao; Lee, Wen-Ya; Kong, Desheng; Pfattner, Raphael; Schweicher, Guillaume; Nakajima, Reina; Lu, Chien; Mei, Jianguo; Lee, Tae Hoon; Wu, Hung-Chin; Lopez, Jeffery; Diao, Ying; Gu, Xiaodan; Himmelberger, Scott; Niu, Weijun; Matthews, James R.; He, Mingqian; Salleo, Alberto; Nishi, Yoshio; Bao, Zhenan

    2015-01-01

    Both high gain and transconductance at low operating voltages are essential for practical applications of organic field-effect transistors (OFETs). Here, we describe the significance of the double-layer capacitance effect in polar rubbery dielectrics, even when present in a very low ion concentration and conductivity. We observed that this effect can greatly enhance the OFET transconductance when driven at low voltages. Specifically, when the polar elastomer poly(vinylidene fluoride-co-hexafluoropropylene) (e-PVDF-HFP) was used as the dielectric layer, despite a thickness of several micrometers, we obtained a transconductance per channel width 30 times higher than that measured for the same organic semiconductors fabricated on a semicrystalline PVDF-HFP with a similar thickness. After a series of detailed experimental investigations, we attribute the above observation to the double-layer capacitance effect, even though the ionic conductivity is as low as 10–10 S/cm. Different from previously reported OFETs with double-layer capacitance effects, our devices showed unprecedented high bias-stress stability in air and even in water. PMID:26658331

  17. Photovoltaic-STATCOM with Low Voltage Ride through Strategy and Power Quality Enhancement in a Grid Integrated Wind-PV System

    Directory of Open Access Journals (Sweden)

    Lakshman Naik Popavath

    2018-04-01

    Full Text Available The traditional configurations of power systems are changing due to the greater penetration of renewable energy sources (solar and wind, resulting in reliability issues. At present, the most severe power quality problems in distribution systems are current harmonics, reactive power demands, and the islanding of renewables caused by severe voltage variations (voltage sag and swell. Current harmonics and voltage sag strongly affect the performance of renewable-based power systems. Various conventional methods (passive filters, capacitor bank, and UPS are not able to mitigate harmonics and voltage sag completely. Based on several studies, custom power devices can mitigate harmonics completely and slightly mitigate voltage sags with reactive power supplies. To ensure the generating units remain grid-connected during voltage sags and to improve system operation during abnormal conditions, efficient and reliable utilization of PV solar farm inverter as STATCOMs is needed. This paper elaborates the dynamic performance of a VSC-based PV-STATCOM for power quality enhancement in a grid integrated system and low voltage ride through (LVRT capability. LVRT requirements suggest that the injection of real and reactive power supports grid voltage during abnormal grid conditions. The proposed strategy was demonstrated with MATLAB simulations.

  18. Self-assembled monolayer exchange reactions as a tool for channel interface engineering in low-voltage organic thin-film transistors.

    Science.gov (United States)

    Lenz, Thomas; Schmaltz, Thomas; Novak, Michael; Halik, Marcus

    2012-10-02

    In this work, we compared the kinetics of monolayer self-assembly long-chained carboxylic acids and phosphonic acids on thin aluminum oxide surfaces and investigated their dielectric properties in capacitors and low-voltage organic thin-film transistors. Phosphonic acid anchor groups tend to substitute carboxylic acid molecules on aluminum oxide surfaces and thus allow the formation of mixed or fully exchanged monolayers. With different alkyl chain substituents (n-alkyl or fluorinated alkyl chains), the exchange reaction can be monitored as a function of time by static contact angle measurements. The threshold voltage in α,α'-dihexyl-sexithiophene thin-film transistors composed of such mixed layer dielectrics correlates with the exchange progress and can be tuned from negative to positive values or vice versa depending on the dipole moment of the alkyl chain substituents. The change in the dipole moment with increasing exchange time also shifts the capacitance of these devices. The rate constants for exchange reactions determined by the time-dependent shift of static contact angle, threshold voltage, and capacitance exhibit virtually the same value thus proving the exchange kinetics to be highly controllable. In general, the exchange approach is a powerful tool in interface engineering, displaying a great potential for tailoring of device characteristics.

  19. Proposal for the award of an industrial services contract for electrical installation work and maintenance of lighting and low-voltage distribution

    CERN Document Server

    2000-01-01

    This document concerns the award of an Industrial Services contract for electrical installation work and maintenance of lighting and low-voltage distribution. Following a market survey carried out among 127 firms in fifteen Member States, a call for tenders (IT-2754/ST) was sent on 2 June 2000 to three firms and four consortia, each consisting of two firms, in four Member States. By the closing date, CERN had received tenders from two firms and two consortia in four Member States. The Finance Committee is invited to agree to the negotiation of a contract with the consortium SPIE TRINDEL(FR) ? CONTROLMATIC (DE), the lowest bidder complying with the specified requirements, for an initial period of three years from 1 July 2001 for a total amount of 41 705 497 Swiss francs, not subject to revision until 31 December 2003. The contract will include options for two one-year extensions beyond the initial three-year period for a total amount of 27 803 664 Swiss francs, for which CERN will seek approval by the Finance ...

  20. Main Memory

    OpenAIRE

    Boncz, Peter; Liu, Lei; Özsu, M.

    2008-01-01

    htmlabstractPrimary storage, presently known as main memory, is the largest memory directly accessible to the CPU in the prevalent Von Neumann model and stores both data and instructions (program code). The CPU continuously reads instructions stored there and executes them. It is also called Random Access Memory (RAM), to indicate that load/store instructions can access data at any location at the same cost, is usually implemented using DRAM chips, which are connected to the CPU and other per...

  1. Graphene-supporting films and low-voltage STEM in SEM toward imaging nanobio materials without staining: Observation of insulin amyloid fibrils.

    Science.gov (United States)

    Ogawa, Takashi; Gang, Geun Won; Thieu, Minh Thu; Kwon, Hyuksang; Ahn, Sang Jung; Ha, Tai Hwan; Cho, Boklae

    2017-05-01

    Utilization of graphene-supporting films and low-voltage scanning transmission electron microscopy (LV-STEM) in scanning electron microscopy (SEM) is shown to be an effective means of observing unstained nanobio materials. Insulin amyloid fibrils, which are implicated as a cause of type II diabetes, are formed in vitro and observed without staining at room temperature. An in-lens cold field-emission SEM, equipped with an additional homemade STEM detector, provides dark field (DF)-STEM images in the low energy range of 5-30keV, together with secondary electron (SE) images. Analysis based on Lenz's theory is used to interpret the experimental results. Graphene films, where the fibrils are deposited, reduce the background level of the STEM images compared with instances when conventional amorphous carbon films are used. Using 30keV, which is lower than that for conventional TEM (100-300keV), together with low detection angles (15-55mrad) enhances the signals from the fibrils. These factors improve image quality, which enables observation of thin fibrils with widths of 7-8nm. STEM imaging clearly reveals a twisted-ribbon structure of a fibril, and SE imaging shows an emphasized striped pattern of the fibril. The LV-STEM in SEM enables acquisition of two types of images of an identical fibril in a single instrument, which is useful for understanding the structure. This study expands the application of SEM to other systems of interest, which is beneficial to a large number of users. The method in this study can be applied to the observation of various nanobio materials and analysis of their native structures, thus contributing to research in materials and life sciences. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Main findings

    International Nuclear Information System (INIS)

    2014-01-01

    Licensing regimes vary from country to country. When the license regime involves several regulators and several licenses, this may lead to complex situations. Identifying a leading organisation in charge of overall coordination including preparation of the licensing decision is a useful practice. Also, if a stepwise licensing process is implemented, it is important to fix in legislation decisions and/or time points and to identify the relevant actors. There is considerable experience in civil and mining engineering that can be applied when constructing a deep geological disposal facility. Specific challenges are, however, the minimization of disturbances to the host rock and the understanding of its long-term behavior. Construction activities may affect the geo-hydraulic and geochemical properties of the various system components which are important safety features of the repository system. Clearly defined technical specifications and an effective quality management plan are important in ensuring successful repository implementation which is consistent with safety requirements. Monitoring plan should also be defined in advance. The regulatory organization should prepare itself to the licensing review before construction by allocating sufficient resources. It should increase its competence, e.g., by interacting early with the implementer and through its own R and D. This will allow the regulator to define appropriate technical conditions associated to the construction license and to elaborate a relevant inspection plan of the construction work. After construction, obtaining the operational license is the most important and crucial step. Main challenges include (a) establishing sufficient confidence so that the methods for closing the individual disposal units comply with the safety objectives and (b) addressing the issue of ageing of materials during a 50-100 years operational period. This latter challenge is amplified when reversibility/retrievability is required

  3. Análisis estadístico de la caída de tensión en un sistema eléctrico de baja tensión: Statistical analysis of the voltage drop in a low voltage electrical system

    Directory of Open Access Journals (Sweden)

    Juan M. Astorga Gómez

    2013-06-01

    Full Text Available En este trabajo se presenta un enfoque estadístico para la evaluación de la caída de tensión en un sistema eléctrico de baja tensión, basado en la aplicación de dos herramientas básicas del control estadístico de procesos conocidas como cartas de control y análisis de capacidad de procesos. Se muestran los resultados para dos sistemas de prueba, se realizan las pruebas de normalidad y autocorrelación parcial para las muestras, se interpretan los resultados de las cartas de control Xbarra-S y se evalúa la capacidad del proceso considerando las bases del mejoramiento de la calidad. Los sistemas de prueba usados en este trabajo son un sistema eléctrico monofásico de baja tensión y un sistema eléctrico trifásico de baja tensión. El objetivo principal de este trabajo es evaluar el estado de control estadístico de la variable de proceso “caída de tensión”, como herramienta para el mejoramiento continuo de los procesos eléctricos.This paper presents a statistical approach for the evaluation of the voltage drop in a low voltage electrical system, based on the application of two basic tools of statistical process control known as control charts and process capability analysis. The results for two test systems are shown, testing of normality and partial autocorrelation for samples are performed, the results of the control charts Xbar-S are interpreted and the process capability analysis are assessed considering the foundations for the quality improvement. The test systems used in this work are one electrical system single-phase low voltage and one electrical system of three-phase low voltage. The main objective of this paper is to evaluate the state of statistical control of the process variable "voltage drop", as a tool for continuous improvement of the electrical process.

  4. Análisis estadístico de la caída de tensión en un sistema eléctrico de baja tensión; Statistical analysis of the voltage drop in a low voltage electrical system

    Directory of Open Access Journals (Sweden)

    Juan M. Astorga Gómez

    2013-06-01

    Full Text Available En este trabajo se presenta un enfoque estadístico para la evaluación de la caída de tensión en un sistema eléctrico de baja tensión, basado en la aplicación de dos herramientas básicas del control estadístico de procesos conocidas como cartas de control y análisis de capacidad de procesos. Se muestran los resultados para dos sistemas de prueba, se realizan las pruebas de normalidad y autocorrelación parcial para las muestras, se interpretan los resultados de las cartas de control Xbarra-S y se evalúa la capacidad del proceso considerando las bases del mejoramiento de la calidad. Los sistemas de prueba usados en este trabajo son un sistema eléctrico monofásico de baja tensión y un sistema eléctrico trifásico de baja tensión. El objetivo principal de este trabajo es evaluar el estado de control estadístico de la variable de proceso “caída de tensión”, como herramienta para el mejoramiento continuo de los procesos eléctricos.  This paper presents a statistical approach for the evaluation of the voltage drop in a low voltage electrical system, based on the application of two basic tools of statistical process control known as control charts and process capability analysis. The results for two test systems are shown, testing of normality and partial autocorrelation for samples are performed, the results of the control charts Xbar-S are interpreted and the process capability analysis are assessed considering the foundations for the quality improvement. The test systems used in this work are one electrical system single-phase low voltage and one electrical system of three-phase low voltage. The main objective of this paper is to evaluate the state of statistical control of the process variable "voltage drop", as a tool for continuous improvement of the electrical process.

  5. Feasibility of high-speed power line carrier system to Japanese overhead low voltage distribution lines; Teiatsu haidensen hanso no kosokuka no kanosei (hanso sningo denpa purogram no kanosei)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, T.; Takeshita, K.; Ishino, R.

    2000-06-01

    The high-speed distribution line carrier systems on underground distribution lines are being developed in Germany. To estimate these systems on Japanese overhead low voltage distribution lines, the Carrier Propagation Program has been developed and applicability of OFDM system was roughly estimated. 1. Carrier Propagation Program Carrier Propagation Program that calculates the carrier propagation characteristics of any line structure was developed. 2. Carrier propagation characteristics Carrier propagation characteristics on typical Japanese overhead low voltage distribution lines were calculated 3.Rough estimation of OFDM system Electric fields caused by carrier at near point were calculated on the basis on carrier propagation characteristics. Results of rough estimation are as follows: - Electric field caused by carrier of more than 2Mbps system exceeds the value of the regulation. (author)

  6. A method for load management in low voltage grids. Application from e-mobility to heat storage; Verfahren zum Lastmanagement in Niederspannungsnetzen. Anwendung von E-Mobility bis Waermespeicher

    Energy Technology Data Exchange (ETDEWEB)

    Hess, Tobias; Schegner, Peter [TU Dresden (Germany). IEEH; Hable, Matthias [ENSO NETZ GmbH, Dresden (Germany)

    2012-07-01

    With the expected charging characteristic of e-mobility a considerable load peak during the night is expected. The paper describes the application of a modified maximal rectangle algorithm to determine the optimal starting times for charging to realise a flat load curve. The load characteristic of e-mobility is similar to heat storage. This allows to use the currently widely spread heat storage devices as example for developing and testing methods for optimized load management in low voltage networks. It is shown that the developed optimization algorithm finds solutions close to the global optimum even in large networks ({approx} 25000 devices) with low requirements of calculation time (< 1 min). (orig.)

  7. Electronic Power Transformer Control Strategy in Wind Energy Conversion Systems for Low Voltage Ride-through Capability Enhancement of Directly Driven Wind Turbines with Permanent Magnet Synchronous Generators (D-PMSGs

    Directory of Open Access Journals (Sweden)

    Hui Huang

    2014-11-01

    Full Text Available This paper investigates the use of an Electronic Power Transformer (EPT incorporated with an energy storage system to smooth the wind power fluctuations and enhance the low voltage ride-through (LVRT capability of directly driven wind turbines with permanent magnet synchronous generators (D-PMSGs. The decoupled control schemes of the system, including the grid side converter control scheme, generator side converter control scheme and the control scheme of the energy storage system, are presented in detail. Under normal operating conditions, the energy storage system absorbs the high frequency component of the D-PMSG output power to smooth the wind power fluctuations. Under grid fault conditions, the energy storage system absorbs the redundant power, which could not be transferred to the grid by the EPT, to help the D-PMSG to ride through low voltage conditions. This coordinated control strategy is validated by simulation studies using MATLAB/Simulink. With the proposed control strategy, the output wind power quality is improved and the D-PMSG can ride through severe grid fault conditions.

  8. Research of analysis method of on-line monitoring based on the behavior analysis of low-voltage users stealing electricity%基于用电行为分析的低压用户窃电在线监测分析方法研究

    Institute of Scientific and Technical Information of China (English)

    姚伟智; 林幕群; 纪素娜; 郑青娜; 杨军

    2015-01-01

    针对目前低压用户窃电十分普遍,窃电手段多种多样,以及现有防窃电措施的不足,为此研究了一套基于低压用户用电行为分析的在线监测方法。依据是用户用电规律与同行业用电轨迹进行对比分析,本方法分析的主要指标包括用户月电量离散系数、行业平均月电量离散系数、两者之间的比值、用户与行业月电量比值,并计算用户异常分值,最终通过异常阀值筛选、排查确定出偏离正常用电轨迹的异常用户。通过运用该分析方法,基本能够做到及时、准确的将偏离正常用电轨迹的窃电用户找出。%Aiming at The universality of the low voltage of stealing electricity, stealing with many kinds of means, and the deficiency of the existing electricity larceny prevention measures,for this purpose,an analysis method of on-line monitoring is studied based on the behavior analysis of low-voltage users stealing electricity. On the basis of the user is contrast and analysis of the electricity laws and the same industry electricity trajectory analysis method, the main indicators include user monthly consumption dispersion coefficient, the industry average monthly consumption dispersion coefficient, between the user and the industry monthly consumption ratio, ratio, and calculate the user abnormal points value, final y through the anomaly threshold determined screening, investigation abnormal user deviates from the normal electricity trajectory. By using the analysis method, the basic can timely and accurate wil deviate from the normal electricity stealing users find out trajectory.

  9. Generation of plasmas in water: utilization of a high-frequency, low-voltage bipolar pulse power supply with impedance control

    International Nuclear Information System (INIS)

    Baroch, P; Potocky, S; Saito, N

    2011-01-01

    Presented work focuses on the investigation and characterization of plasma discharges generated in water by newly developed bipolar pulse power supply. The main aim of our work was to solve and overcome problems with intensive arc discharge transition when the discharge is ignited and maintained by a low output impedance pulse power supply. For this purpose a novel type of bipolar pulse power supply was developed and tested. It was found that two distinguished stable modes of discharges generated in the water can be realized. Effects of water conductivity, pulse frequency and initial water temperature on the discharge properties were investigated. Optical emission spectroscopy was employed to study plasma parameters of the discharge and the correlation between the data obtained from the optical emission spectroscopy and the chemical species measured in the water was carried out.

  10. Optimal operation control of low-voltage grids with a high share of distributed power generation[Dissertation 17063]; Optimierte Betriebsfuehrung von Niederspannungsnetzen mit einem hohen Anteil an dezentraler Erzeugung

    Energy Technology Data Exchange (ETDEWEB)

    Malte, C. T.

    2007-07-01

    The importance of renewable energy sources and combined heat and power generation for electricity production will further increase in the next years, not only in Germany but all over Europe. Beside the conventional more or less centrally organised generation and distribution structure, more and more distributed generation (DG) units of different technologies will come to the forefront. Today's centrally organised electricity supply structure is comparatively stable, relatively simple to control and guarantees a high degree of supply quality. But it requests large investments with a long commitment, is less flexible and can barely use efficiency potentials. Distribution grids (low and medium voltage) are essentially passive; this means that the network management is carried out at the higher voltage levels. As more and more DG units feed in the grid, the distribution grids have to become more 'active'. With a high share of wind power, combined heat and power as well as photovoltaic generation, more duties of grid management have to be carried out at the point of common coupling of DG units. This requests for more communication und new control strategies in the distribution grids. At the same time grids with DG have in the mid-term the potential to reduce the susceptibility for large scale black-outs, because, on one hand, with a high number of smaller and individually controlled DG units the breakdown of one unit does not have a major impact and, on the other hand, with a specific grid management the option exists to build up islanded grids during interruptions on the higher voltage levels and to continue to supply the connected customers. In the European research project 'DISPOWER' 38 institutions from all over Europe dealt these topics. In this context a new kind of energy management system for low voltage grids was developed: 'PoMS'. PoMS is the acronym for 'Power Flow and Power Quality Management System'. Major

  11. Optimal operation control of low-voltage grids with a high share of distributed power generation[Dissertation 17063]; Optimierte Betriebsfuehrung von Niederspannungsnetzen mit einem hohen Anteil an dezentraler Erzeugung

    Energy Technology Data Exchange (ETDEWEB)

    Malte, C T

    2007-07-01

    The importance of renewable energy sources and combined heat and power generation for electricity production will further increase in the next years, not only in Germany but all over Europe. Beside the conventional more or less centrally organised generation and distribution structure, more and more distributed generation (DG) units of different technologies will come to the forefront. Today's centrally organised electricity supply structure is comparatively stable, relatively simple to control and guarantees a high degree of supply quality. But it requests large investments with a long commitment, is less flexible and can barely use efficiency potentials. Distribution grids (low and medium voltage) are essentially passive; this means that the network management is carried out at the higher voltage levels. As more and more DG units feed in the grid, the distribution grids have to become more 'active'. With a high share of wind power, combined heat and power as well as photovoltaic generation, more duties of grid management have to be carried out at the point of common coupling of DG units. This requests for more communication und new control strategies in the distribution grids. At the same time grids with DG have in the mid-term the potential to reduce the susceptibility for large scale black-outs, because, on one hand, with a high number of smaller and individually controlled DG units the breakdown of one unit does not have a major impact and, on the other hand, with a specific grid management the option exists to build up islanded grids during interruptions on the higher voltage levels and to continue to supply the connected customers. In the European research project 'DISPOWER' 38 institutions from all over Europe dealt these topics. In this context a new kind of energy management system for low voltage grids was developed: 'PoMS'. PoMS is the acronym for 'Power Flow and Power Quality Management System'. Major targets during development were that the system is

  12. A novel low-voltage low-power analogue VLSI implementation of neural networks with on-chip back-propagation learning

    Science.gov (United States)

    Carrasco, Manuel; Garde, Andres; Murillo, Pilar; Serrano, Luis

    2005-06-01

    In this paper a novel design and implementation of a VLSI Analogue Neural Net based on Multi-Layer Perceptron (MLP) with on-chip Back Propagation (BP) learning algorithm suitable for the resolution of classification problems is described. In order to implement a general and programmable analogue architecture, the design has been carried out in a hierarchical way. In this way the net has been divided in synapsis-blocks and neuron-blocks providing an easy method for the analysis. These blocks basically consist on simple cells, which are mainly, the activation functions (NAF), derivatives (DNAF), multipliers and weight update circuits. The analogue design is based on current-mode translinear techniques using MOS transistors working in the weak inversion region in order to reduce both the voltage supply and the power consumption. Moreover, with the purpose of minimizing the noise, offset and distortion of even order, the topologies are fully-differential and balanced. The circuit, named ANNE (Analogue Neural NEt), has been prototyped and characterized as a proof of concept on CMOS AMI-0.5A technology occupying a total area of 2.7mm2. The chip includes two versions of neural nets with on-chip BP learning algorithm, which are respectively a 2-1 and a 2-2-1 implementations. The proposed nets have been experimentally tested using supply voltages from 2.5V to 1.8V, which is suitable for single cell lithium-ion battery supply applications. Experimental results of both implementations included in ANNE exhibit a good performance on solving classification problems. These results have been compared with other proposed Analogue VLSI implementations of Neural Nets published in the literature demonstrating that our proposal is very efficient in terms of occupied area and power consumption.

  13. Contribution of S4 segments and S4-S5 linkers to the low-voltage activation properties of T-type CaV3.3 channels.

    Directory of Open Access Journals (Sweden)

    Ana Laura Sanchez-Sandoval

    Full Text Available Voltage-gated calcium channels contain four highly conserved transmembrane helices known as S4 segments that exhibit a positively charged residue every third position, and play the role of voltage sensing. Nonetheless, the activation range between high-voltage (HVA and low-voltage (LVA activated calcium channels is around 30-40 mV apart, despite the high level of amino acid similarity within their S4 segments. To investigate the contribution of S4 voltage sensors for the low-voltage activation characteristics of CaV3.3 channels we constructed chimeras by swapping S4 segments between this LVA channel and the HVA CaV1.2 channel. The substitution of S4 segment of Domain II in CaV3.3 by that of CaV1.2 (chimera IIS4C induced a ~35 mV shift in the voltage-dependence of activation towards positive potentials, showing an I-V curve that almost overlaps with that of CaV1.2 channel. This HVA behavior induced by IIS4C chimera was accompanied by a 2-fold decrease in the voltage-dependence of channel gating. The IVS4 segment had also a strong effect in the voltage sensing of activation, while substitution of segments IS4 and IIIS4 moved the activation curve of CaV3.3 to more negative potentials. Swapping of IIS4 voltage sensor influenced additional properties of this channel such as steady-state inactivation, current decay, and deactivation. Notably, Domain I voltage sensor played a major role in preventing CaV3.3 channels to inactivate from closed states at extreme hyperpolarized potentials. Finally, site-directed mutagenesis in the CaV3.3 channel revealed a partial contribution of the S4-S5 linker of Domain II to LVA behavior, with synergic effects observed in double and triple mutations. These findings indicate that IIS4 and, to a lesser degree IVS4, voltage sensors are crucial in determining the LVA properties of CaV3.3 channels, although the accomplishment of this function involves the participation of other structural elements like S4-S5 linkers.

  14. Contribution of S4 segments and S4-S5 linkers to the low-voltage activation properties of T-type CaV3.3 channels

    Science.gov (United States)

    Sanchez-Sandoval, Ana Laura; Herrera Carrillo, Zazil; Díaz Velásquez, Clara Estela; Delgadillo, Dulce María; Rivera, Heriberto Manuel

    2018-01-01

    Voltage-gated calcium channels contain four highly conserved transmembrane helices known as S4 segments that exhibit a positively charged residue every third position, and play the role of voltage sensing. Nonetheless, the activation range between high-voltage (HVA) and low-voltage (LVA) activated calcium channels is around 30–40 mV apart, despite the high level of amino acid similarity within their S4 segments. To investigate the contribution of S4 voltage sensors for the low-voltage activation characteristics of CaV3.3 channels we constructed chimeras by swapping S4 segments between this LVA channel and the HVA CaV1.2 channel. The substitution of S4 segment of Domain II in CaV3.3 by that of CaV1.2 (chimera IIS4C) induced a ~35 mV shift in the voltage-dependence of activation towards positive potentials, showing an I-V curve that almost overlaps with that of CaV1.2 channel. This HVA behavior induced by IIS4C chimera was accompanied by a 2-fold decrease in the voltage-dependence of channel gating. The IVS4 segment had also a strong effect in the voltage sensing of activation, while substitution of segments IS4 and IIIS4 moved the activation curve of CaV3.3 to more negative potentials. Swapping of IIS4 voltage sensor influenced additional properties of this channel such as steady-state inactivation, current decay, and deactivation. Notably, Domain I voltage sensor played a major role in preventing CaV3.3 channels to inactivate from closed states at extreme hyperpolarized potentials. Finally, site-directed mutagenesis in the CaV3.3 channel revealed a partial contribution of the S4-S5 linker of Domain II to LVA behavior, with synergic effects observed in double and triple mutations. These findings indicate that IIS4 and, to a lesser degree IVS4, voltage sensors are crucial in determining the LVA properties of CaV3.3 channels, although the accomplishment of this function involves the participation of other structural elements like S4-S5 linkers. PMID:29474447

  15. Contribution of S4 segments and S4-S5 linkers to the low-voltage activation properties of T-type CaV3.3 channels.

    Science.gov (United States)

    Sanchez-Sandoval, Ana Laura; Herrera Carrillo, Zazil; Díaz Velásquez, Clara Estela; Delgadillo, Dulce María; Rivera, Heriberto Manuel; Gomora, Juan Carlos

    2018-01-01

    Voltage-gated calcium channels contain four highly conserved transmembrane helices known as S4 segments that exhibit a positively charged residue every third position, and play the role of voltage sensing. Nonetheless, the activation range between high-voltage (HVA) and low-voltage (LVA) activated calcium channels is around 30-40 mV apart, despite the high level of amino acid similarity within their S4 segments. To investigate the contribution of S4 voltage sensors for the low-voltage activation characteristics of CaV3.3 channels we constructed chimeras by swapping S4 segments between this LVA channel and the HVA CaV1.2 channel. The substitution of S4 segment of Domain II in CaV3.3 by that of CaV1.2 (chimera IIS4C) induced a ~35 mV shift in the voltage-dependence of activation towards positive potentials, showing an I-V curve that almost overlaps with that of CaV1.2 channel. This HVA behavior induced by IIS4C chimera was accompanied by a 2-fold decrease in the voltage-dependence of channel gating. The IVS4 segment had also a strong effect in the voltage sensing of activation, while substitution of segments IS4 and IIIS4 moved the activation curve of CaV3.3 to more negative potentials. Swapping of IIS4 voltage sensor influenced additional properties of this channel such as steady-state inactivation, current decay, and deactivation. Notably, Domain I voltage sensor played a major role in preventing CaV3.3 channels to inactivate from closed states at extreme hyperpolarized potentials. Finally, site-directed mutagenesis in the CaV3.3 channel revealed a partial contribution of the S4-S5 linker of Domain II to LVA behavior, with synergic effects observed in double and triple mutations. These findings indicate that IIS4 and, to a lesser degree IVS4, voltage sensors are crucial in determining the LVA properties of CaV3.3 channels, although the accomplishment of this function involves the participation of other structural elements like S4-S5 linkers.

  16. Autonomous Operation of Low Voltage Microgrids

    Directory of Open Access Journals (Sweden)

    Irena Wasiak

    2014-12-01

    Full Text Available The article describes the possibilities of LV microgrids operation in the island mode. Control strategies of energy sources connected to the grid by means of invertors are discussed, either for a microgrid connected to the supplying network or during the island mode operation. The presented results of research were conducted at the Laboratory of Distributed Generation at Lodz University of Technology. The study was performed for two variants of reference voltage source: the battery storage and microturbine respectively.

  17. Ultra-low Voltage CMOS Cascode Amplifier

    OpenAIRE

    Lehmann, Torsten; Cassia, Marco

    2000-01-01

    In this paper, we design a folded cascode operational transconductance amplifier in a standard CMOS process, which has a measured 69 dB DC gain, a 2 MHz bandwidth and compatible input- and output voltage levels at a 1 V power supply. This is done by a novel Current Driven Bulk (CDB) technique, which reduces the MOST threshold voltage by forcing a constant current though the transistor bulk terminal. We also look at limitations and improvements of this CDB technique.

  18. Low Voltage Low Light Imager and Photodetector

    Science.gov (United States)

    Nikzad, Shouleh (Inventor); Martin, Chris (Inventor); Hoenk, Michael E. (Inventor)

    2013-01-01

    Highly efficient, low energy, low light level imagers and photodetectors are provided. In particular, a novel class of Della-Doped Electron Bombarded Array (DDEBA) photodetectors that will reduce the size, mass, power, complexity, and cost of conventional imaging systems while improving performance by using a thinned imager that is capable of detecting low-energy electrons, has high gain, and is of low noise.

  19. Ultra-low Voltage CMOS Cascode Amplifier

    DEFF Research Database (Denmark)

    Lehmann, Torsten; Cassia, Marco

    2000-01-01

    In this paper, we design a folded cascode operational transconductance amplifier in a standard CMOS process, which has a measured 69 dB DC gain, a 2 MHz bandwidth and compatible input- and output voltage levels at a 1 V power supply. This is done by a novel Current Driven Bulk (CDB) technique......, which reduces the MOST threshold voltage by forcing a constant current though the transistor bulk terminal. We also look at limitations and improvements of this CDB technique....

  20. Ultra Low-Voltage Energy Harvesting

    Science.gov (United States)

    2013-09-01

    if in a solar battery charger the level of illumination were to drop due to cloud cover, the diode would prevent discharging of the battery when...the source voltage becomes lower than battery voltage. The drawback of a simple circuit like this is that once the source voltage is lower than the...longer charged when the battery voltage is above the OV setting. Figure 13. Block diagram of BQ25504 circuit . (From [10]) 18 THIS PAGE

  1. Low-Voltage Switched-Capacitor Circuits

    DEFF Research Database (Denmark)

    Bidari, E.; Keskin, M.; Maloberti, F.

    1999-01-01

    Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications.......Switched-capacitor stages are described which can function with very low (typically 1 V) supply voltages, without using voltage boosting or switched op-amps. Simulations indicate that high performance may be achieved using these circuits in filter or data converter applications....

  2. Direct observation and analysis of york-shell materials using low-voltage high-resolution scanning electron microscopy: Nanometal-particles encapsulated in metal-oxide, carbon, and polymer

    Directory of Open Access Journals (Sweden)

    Shunsuke Asahina

    2014-11-01

    Full Text Available Nanometal particles show characteristic features in chemical and physical properties depending on their sizes and shapes. For keeping and further enhancing their features, the particles should be protected from coalescence or degradation. One approach is to encapsulate the nanometal particles inside pores with chemically inert or functional materials, such as carbon, polymer, and metal oxides, which contain mesopores to allow permeation of only chemicals not the nanometal particles. Recently developed low-voltage high-resolution scanning electron microscopy was applied to the study of structural, chemical, and electron state of both nanometal particles and encapsulating materials in york-shell materials of Au@C, Ru/Pt@C, Au@TiO2, and Pt@Polymer. Progresses in the following categories were shown for the york-shell materials: (i resolution of topographic image contrast by secondary electrons, of atomic-number contrast by back-scattered electrons, and of elemental mapping by X-ray energy dispersive spectroscopy; (ii sample preparation for observing internal structures; and (iii X-ray spectroscopy such as soft X-ray emission spectroscopy. Transmission electron microscopy was also used for characterization of Au@C.

  3. Direct observation and analysis of yolk-shell materials using low-voltage high-resolution scanning electron microscopy: Nanometal-particles encapsulated in metal-oxide, carbon, and polymer

    Energy Technology Data Exchange (ETDEWEB)

    Asahina, Shunsuke; Suga, Mitsuo; Takahashi, Hideyuki [JEOL Ltd., SM Business Unit, Tokyo (Japan); Young Jeong, Hu [Graduate School of EEWS, WCU/BK21+, KAIST, Daejeon 305-701 (Korea, Republic of); Galeano, Carolina; Schüth, Ferdi [Department of Heterogeneous Catalysis, Max-Planck-Institut für Kohlenforschung, Mülheim (Germany); Terasaki, Osamu, E-mail: terasaki@mmk.su.se, E-mail: terasaki@kaist.ac.kr [Graduate School of EEWS, WCU/BK21+, KAIST, Daejeon 305-701 (Korea, Republic of); Department of Materials and Environmental Chemistry, Berzelii Centre EXSELENT on Porous Materials, Stockholm University, SE-10691 Stockholm (Sweden)

    2014-11-01

    Nanometal particles show characteristic features in chemical and physical properties depending on their sizes and shapes. For keeping and further enhancing their features, the particles should be protected from coalescence or degradation. One approach is to encapsulate the nanometal particles inside pores with chemically inert or functional materials, such as carbon, polymer, and metal oxides, which contain mesopores to allow permeation of only chemicals not the nanometal particles. Recently developed low-voltage high-resolution scanning electron microscopy was applied to the study of structural, chemical, and electron state of both nanometal particles and encapsulating materials in yolk-shell materials of Au@C, Ru/Pt@C, Au@TiO{sub 2}, and Pt@Polymer. Progresses in the following categories were shown for the yolk-shell materials: (i) resolution of topographic image contrast by secondary electrons, of atomic-number contrast by back-scattered electrons, and of elemental mapping by X-ray energy dispersive spectroscopy; (ii) sample preparation for observing internal structures; and (iii) X-ray spectroscopy such as soft X-ray emission spectroscopy. Transmission electron microscopy was also used for characterization of Au@C.

  4. Study of Power Quality at the Point of Common Coupling of a Low Voltage Grid and a Distributed Generation System of 7.8 kWp in a Tropical Region

    Directory of Open Access Journals (Sweden)

    Agustín Valverde Granja

    2018-06-01

    Full Text Available In this paper we analyze an experimental 1000 kWh/month distributed generation system in a tropical region connected to a point of common coupling in a low voltage grid that was characterized according to NTC 5001. This photovoltaic system has 7.8 kWp and uses 30 polycrystalline silicon-panels of 260 Wp each. Its maximum energy produced was 850 kWh/month, equivalent to 72.65% of the installed capacity. Finally, there was an increase of 2% with respect to the minimum voltage value that was recorded. The voltage unbalance decreases between 3.5 and 70% and voltage harmonics in each line increased by 7% on line U1, 0.8% on U2, 3% on U3 and current harmonics have a 22% increase. Likewise, the total active and reactive power were increased by 58% and 42% respectively, and the thermography study allowed to establish a temperature increase at the point of common coupling of 7.5%. Therefore, it is expected that this paper can serve as a reference for the application of Colombian law 1715 in solar energy.

  5. High-ratio voltage conversion in CMOS for efficient mains-connected standby

    CERN Document Server

    Meyvaert, Hans

    2016-01-01

    This book describes synergetic innovation opportunities offered by combining the field of power conversion with the field of integrated circuit (IC) design. The authors demonstrate how integrating circuits enables increased operation frequency, which can be exploited in power converters to reduce drastically the size of the discrete passive components. The authors introduce multiple power converter circuits, which are very compact as result of their high level of integration. First, the limits of high-power-density low-voltage monolithic switched-capacitor DC-DC conversion are investigated to enable on-chip power granularization. AC-DC conversion from the mains to a low voltage DC is discussed, enabling an efficient and compact, lower-power auxiliary power supply to take over the power delivery during the standby mode of mains-connected appliances, allowing the main power converter of these devices to be shut down fully. Discusses high-power-density monolithic switched-capacitor DC-DC conversion in bulk CMOS,...

  6. Main Memory DBMS

    NARCIS (Netherlands)

    P.A. Boncz (Peter); L. Liu (Lei); M. Tamer Özsu

    2008-01-01

    htmlabstractA main memory database system is a DBMS that primarily relies on main memory for computer data storage. In contrast, normal database management systems employ hard disk based persisntent storage.

  7. Increasing power distribution mains efficiency through new mains configurations; Effizienzsteigerung im Verteilnetz durch neue Netzkonfigurationen

    Energy Technology Data Exchange (ETDEWEB)

    Hoeckel, M.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) summarises the findings of a study that sought to find new approaches to minimise distribution losses in medium and low voltage power grids. Options examined included the optimisation of distribution-station density, increasing the nominal voltage of the low-voltage grid and the implementation of decentralised energy production. Data from real-life grids were used together with simulations to analyse possible solutions. The conclusions of these analyses are presented and discussed. In addition, qualitative and detailed examinations were made concerning grid quality factors such as availability and voltage stability.

  8. Maine's Employability Skills Program

    Science.gov (United States)

    McMahon, John M.; Wolffe, Karen E.; Wolfe, Judy; Brooker, Carrie

    2013-01-01

    This Practice Report describes the development and implementation of the "Maine Employability Skills Program," a model employment program developed by the Maine Division for the Blind and Visually Impaired (DBVI). The program was designed to support the efforts of the chronically unemployed or underemployed. These consumers were either…

  9. Turbine main engines

    CERN Document Server

    Main, John B; Herbert, C W; Bennett, A J S

    1965-01-01

    Turbine Main Engines deals with the principle of operation of turbine main engines. Topics covered include practical considerations that affect turbine design and efficiency; steam turbine rotors, blades, nozzles, and diaphragms; lubricating oil systems; and gas turbines for use with nuclear reactors. Gas turbines for naval boost propulsion, merchant ship propulsion, and naval main propulsion are also considered. This book is divided into three parts and begins with an overview of the basic mode of operation of the steam turbine engine and how it converts the pressure energy of the ingoing ste

  10. Maine highway safety plan

    Science.gov (United States)

    2010-01-01

    Each September 1, the MeBHS must provide NHTSA a comprehensive plan to reduce : traffic crashes and resulting deaths, injuries and property damage. The Highway Safety : Plan (HSP) serves as Maines application for available federal funds for these ...

  11. Maine Field Station

    Data.gov (United States)

    Federal Laboratory Consortium — In 2000 NOAA's National Marine Fisheries Service established the Maine Field Station in Orono, ME to have more direct involvement in the conservation of the living...

  12. Maine's forests 2008

    Science.gov (United States)

    George L. McCaskill; William H. McWilliams; Charles J. Barnett; Brett J. Butler; Mark A. Hatfield; Cassandra M. Kurtz; Randall S. Morin; W. Keith Moser; Charles H. Perry; Christopher W. Woodall

    2011-01-01

    The second annual inventory of Maine's forests was completed in 2008 after more than 3,160 forested plots were measured. Forest land occupies almost 17.7 million acres, which represents 82 percent of the total land area of Maine. The dominant forest-type groups are maple/beech/yellow birch, spruce/fir, white/red/jack pine, and aspen/white birch. Statewide volume...

  13. Maine Forests 2013

    Science.gov (United States)

    George L. McCaskill; Thomas Albright; Charles J. Barnett; Brett J. Butler; Susan J. Crocker; Cassandra M. Kurtz; William H. McWilliams; Patrick D. Miles; Randall S. Morin; Mark D. Nelson; Richard H. Widmann; Christopher W. Woodall

    2016-01-01

    The third 5-year annualized inventory of Maine's forests was completed in 2013 after more than 3170 forested plots were measured. Maine contains more than 17.6 million acres of forest land, an area that has been quite stable since 1960, covering more than 82 percent of the total land area. The number of live trees greater than 1 inch in diameter are approaching 24...

  14. Main sequence mass loss

    International Nuclear Information System (INIS)

    Brunish, W.M.; Guzik, J.A.; Willson, L.A.; Bowen, G.

    1987-01-01

    It has been hypothesized that variable stars may experience mass loss, driven, at least in part, by oscillations. The class of stars we are discussing here are the δ Scuti variables. These are variable stars with masses between about 1.2 and 2.25 M/sub θ/, lying on or very near the main sequence. According to this theory, high rotation rates enhance the rate of mass loss, so main sequence stars born in this mass range would have a range of mass loss rates, depending on their initial rotation velocity and the amplitude of the oscillations. The stars would evolve rapidly down the main sequence until (at about 1.25 M/sub θ/) a surface convection zone began to form. The presence of this convective region would slow the rotation, perhaps allowing magnetic braking to occur, and thus sharply reduce the mass loss rate. 7 refs

  15. ANÁLISIS Y ESTUDIO DEL DESEMPEÑO DEL CÓDIGO CHEQUEO DE PARIDAD DE BAJA DENSIDAD IRREGULAR EN UN CANAL DE LÍNEA ELÉCTRICA DE BAJA TENSIÓN ANALYSIS AND STUDY OF THE PERFORMANCE OF THE IRREGULAR LOW DENSITY PARITY CHECK CODE IN LOW VOLTAGE POWERLINE

    Directory of Open Access Journals (Sweden)

    Washington Fernández R

    2009-04-01

    Full Text Available En este trabajo se analiza y estudia el código chequeo de paridad de baja densidad irregular (LDPC, en un canal de línea eléctrica de baja tensión. Se analizan los modelos de ruido existentes para las líneas eléctricas de baja tensión. Se evalúa el desempeño del código LDPC irregular, en un canal de línea eléctrica de baja tensión para diferentes velocidades de transmisión (3, 10, 15 y 30 Mbps, considerando como parámetro de desempeño el BER versus SNR.In this work the irregular Low Density Parity Check code (LDPC is analyzed and studied, is used in a low voltage powerline. Noise models are analyzed for these low voltage lines. The performance of the LDPC code is evaluated in a low voltage line channel for rates of 3, 5, 15 and 30 Mbps, considering of BER vs SNR a parameter.

  16. FERMILAB: Main Injector

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    The Fermilab Main Injector (FMI) project is the centerpiece of the Laboratory's Fermilab III programme for the 1990s. Designed to support a luminosity of at least 5x10 31 cm -2 s -1 in the Tevatron collider, it will also provide new capabilities for rare neutral kaon decay and neutrino oscillation studies. The Fermilab Main Injector 8-150 GeV synchrotron is designed to replace the existing Main Ring which seriously limits beam intensities for the Tevatron and the antiproton production target. The project has passed several significant milestones and is now proceeding rapidly towards construction. The project received a $11.65M appropriation in 1992 and has been given $15M for the current fiscal year. Through the Energy Systems Acquisition Advisory Board (ESAAB) process, the US Department of Energy (DoE) has authorized funds for construction of the underground enclosure and service building where the Main Injector will touch the Tevatron, and to the preparation of bids for remaining project construction

  17. FERMILAB: Main Injector

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1993-06-15

    The Fermilab Main Injector (FMI) project is the centerpiece of the Laboratory's Fermilab III programme for the 1990s. Designed to support a luminosity of at least 5x10{sup 31} cm{sup -2} s{sup -1} in the Tevatron collider, it will also provide new capabilities for rare neutral kaon decay and neutrino oscillation studies. The Fermilab Main Injector 8-150 GeV synchrotron is designed to replace the existing Main Ring which seriously limits beam intensities for the Tevatron and the antiproton production target. The project has passed several significant milestones and is now proceeding rapidly towards construction. The project received a $11.65M appropriation in 1992 and has been given $15M for the current fiscal year. Through the Energy Systems Acquisition Advisory Board (ESAAB) process, the US Department of Energy (DoE) has authorized funds for construction of the underground enclosure and service building where the Main Injector will touch the Tevatron, and to the preparation of bids for remaining project construction.

  18. Main facts 1995

    International Nuclear Information System (INIS)

    1996-01-01

    This report presents the main facts of the studies carried out by the Direction des Etudes et Recherches (DER) of Electricite de France: new applications of electricity, classical and nuclear thermal power plants, electrical equipment, environment protection, monitoring and plants operations

  19. Main designations and attributions

    International Nuclear Information System (INIS)

    2010-01-01

    The chapter presents the main designations and attributions of the LNMRI - Brazilian National Laboratory of Metrology of Ionizing Radiation, the Cooperative Center in Radiation Protection and Medical Preparations for Accidents with Radiation; the Treaty for fully banning of nuclear tests and the Regional Center for Training of IAEA

  20. Maine Bouguer Gravity Grid

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A 2 kilometer Bouguer anomaly grid for the state of Maine. Number of columns is 197 and number of rows is 292. The order of the data is from the lower left to the...

  1. Main facts 1993

    International Nuclear Information System (INIS)

    1994-01-01

    This report presents the main facts of the studies carried out by the Direction des Etudes et Recherches (DER) of Electricite de France: new applications of electricity, classical and nuclear thermal power plants, electrical equipment, environment protection, network analysis, information and informatic equipment

  2. Renovating the Main Building

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    CERN's "Main Building" is exactly that. The Organization's central hub, with hundreds of staff and visitors passing through its doors every day, will soon be getting a well-earned facelift. Refurbishment work will proceed in phases, starting with the Salle des Pas Perdus, the concourse between the Council Chamber and the Main Auditorium. By the end of August, informal seating areas will be installed, electronic display panels will provide practical information and improved sound insulation will enhance conditions in the auditoria and surrounding meeting rooms.   In light green the area that will undergo the facelift. Work will start in July. The ground floor is home to the entrance to Restaurant No. 1, the bank, the post office, the travel agent, the Users Office, the Staff Association, the notice boards etc. Step up to the first floor to access CERN's largest lecture theatre, the Council Chamber and its "Pas Perdus" lobby. Everyone who works at or visits CERN i...

  3. Fermilab Main Injector plan

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1990-07-15

    The Fermilab Main Injector is the centrepiece of the 'Fermilab III' scheme to significantly upgrade the Laboratory's existing accelerator complex. The new accelerator is designed to provide increased particle beam levels to boost the collision rate in the Tevatron proton-antiproton collider (luminosity in excess of 5 x 10{sup 31} per sq cm per s) and, if approved, would provide increased flexibility in all areas of high energy physics research.

  4. Fermilab Main Injector plan

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The Fermilab Main Injector is the centrepiece of the 'Fermilab III' scheme to significantly upgrade the Laboratory's existing accelerator complex. The new accelerator is designed to provide increased particle beam levels to boost the collision rate in the Tevatron proton-antiproton collider (luminosity in excess of 5 x 10 31 per sq cm per s) and, if approved, would provide increased flexibility in all areas of high energy physics research

  5. Maine coast winds

    Energy Technology Data Exchange (ETDEWEB)

    Avery, Richard

    2000-01-28

    The Maine Coast Winds Project was proposed for four possible turbine locations. Significant progress has been made at the prime location, with a lease-power purchase contract for ten years for the installation of turbine equipment having been obtained. Most of the site planning and permitting have been completed. It is expect that the turbine will be installed in early May. The other three locations are less suitable for the project, and new locations are being considered.

  6. Project evaluation: main characteristics

    OpenAIRE

    Moutinho, Nuno

    2010-01-01

    — The evaluation process of real investment projects must consider not only the traditional financial approach, but also non-financial aspects. Non financial analysis can provide additional relevant information about projects. We investigate financial and non-financial areas most relevant in project appraisal. We present main critical success factors and areas of analysis that lead to the perception of project success. Finally, companies are segmented to verify its financial and non-financial...

  7. Marketing Maine Tablestock Potatoes

    OpenAIRE

    Berney, Gerald; Grajewski, Gregory; Hinman, Don; Prater, Marvin E.; Taylor, April

    2010-01-01

    The Marketing Services Division of USDA’s Agricultural Marketing Service (AMS) was asked by USDA’s Agricultural Research Service (ARS) National Program Leader and ARS’s New England Soil and Water Research Laboratory personnel to help with existing efforts to assist Maine fresh potato farmers in their search for alternative marketing strategies, and reverse the recent decline in the profitability of their operations. ARS researchers previously had conducted an exhaustive study defining possibl...

  8. Nonlinear dynamics in chemical processes. Project A: Locally distributed periodic processes. Sub-project A3I: Catalitic afterburning. Nonlinear periodic front travelling processes. Final report; Nichtlineare Dynamik bei chemischen Prozessen. Projekt A: Oertlich verteilte periodische Prozesse. Teilprojekt A3I: Katalytische Nachverbrennung im Zirkulationsreaktor. Nichtlineare periodische Frontwanderungsprozesse. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Richter, M.; Reinhardt, H.J.; Roschka, E.

    1998-01-31

    The catalytic conversion of a HC/CHC mixture in a travelling reaction front was investigated in order to apply the circulation reactor principle to the catalytic afterburning of CHC-burdened off-gas. The sub-project `circulating reaction zones` comprised a model-supported analysis and synthesis for establishing process control concepts using the methods of nonlinear dynamics. The experiment showed that the circulation reactor adjusts to different states of operation autonomously. The region of stable oscillation shifts as a result of (reversible) deactivation of the catalyst. With suitable process control measures, the position-dependent maximum temperature of the circulating reaction front can be kept within the catalyst-specific limiting values for total oxidation resp. catalyst damage. On the basis fo the investigations, a technically mature concept for use of the circulation reactor for decomposition of hard-to-crack pollutants was obtained provided that a suitable catalyst is available. The main field of application is the catalytic afterburning of varying pollutant volumes in low-volume off-gas streams in order to make use of the autonomous adaptation of the reactor to a new operating state in case of changing reaction conditions. [Deutsch] Im Rahmen dieses Teilprojektes wurde die katalytische Zersetzung eines Kohlenwasserstoff-Chlorkohlenwasserstoff-Gemischs in wandernder Reaktionsfront untersucht, um das Prinzip des Zirkulationsreaktors auf die katalytische Nachverbrennung von CKW-haltigen Abgasen anzuwenden. Im Teilprojekt `Zirkulierende Reaktionszonen` erfolgte die modellgestuetzte Analyse und Synthese zur Ableitung von Prozessfuehrungskonzepten mit den Methoden der nichtlinearen Dynamik. Bei den Versuchen konnte ein autonomes Einschwingen des Zirkulationsreaktors auf verschiedene Betriebszustaende experimentell nachgewiesen werden. Der Bereich stabiler Oszillation verschiebt sich infolge (reversibler) Desaktivierung des Katalysators. Mit geeigneten

  9. Summary of main points

    International Nuclear Information System (INIS)

    2006-01-01

    In conjunction with its 6. annual meeting, the WPDD in close co-operation with the FSC held a Topical session on 'Stakeholder Involvement in Decommissioning' on November 14, 2005. The session was attended by 36 participants totally representing 14 NEA member countries and 2 international organisations. Two keynote addresses were given at the Topical Session. The first one treated of what is needed for robust decisions and how to bring all stakeholders into the debate. In the second keynote address a summary was made on what have been said on stakeholder involvement in decommissioning during earlier meetings of the WPDD. The main part of the session was then devoted to views from different stakeholders regarding their role and their involvement. This part contained viewpoints from local communities (Kaevlinge in Sweden and Port Hope in Canada), authorities (Scottish Executive and CSNC) and operators (EDF from France and EWN from Germany). Case studies from the decommissioning of Dounrey in the UK and from Trojan and Main Yankee in the USA were presented in the end part of the Topical session followed by a summary and lessons learnt report by the Rapporteur. A detailed programme of the Topical session can be seen in Appendix 1

  10. TRIGA reactor main systems

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2007-01-01

    This module describes the main systems of low power (<2 MW) and higher power (≥2 MW) TRIGA reactors. The most significant difference between the two is that forced reactor cooling and an emergency core cooling system are generally required for the higher power TRIGA reactors. However, those TRIGA reactors that are designed to be operated above 3 MW also use a TRIGA fuel that is specifically designed for those higher power outputs (3 to 14 MW). Typical values are given for the respective systems although each TRIGA facility will have unique characteristics that may only be determined by the experienced facility operators. Due to the inherent wide scope of these research reactor facilities construction and missions, this training module covers those systems found at most operating TRIGA reactor facilities but may also discuss non-standard equipment that was found to be operationally useful although not necessarily required. (author)

  11. Measurements of impedances for determinating the minimum short-circuit current in main systems 500 V of underground mining establishments

    Energy Technology Data Exchange (ETDEWEB)

    Rittinghaus, D

    1981-09-01

    The complex short-circuit impedances of energized low-voltage main systems were measured with a double-bridge in underground mining operation. The magnitude of the short-circuit currents depends on these impedances. Customary calculations of such currents depend on empirical approximations. To verify the accuracy of these approximations, the measured impedances of 61 nodes in three different main systems were compared with the results of the calculations. The comparison made between the short-circuit currents determined by measurable quantities and the values calculated according to VDE 0118 shows that the stipulated coefficients for calculating the minimum short-circuit currents lie very far on the safe side. An amendment for calculating the short-circuit in accordance with VDE 0118 is therefore suggested.

  12. ANÁLISIS Y ESTUDIO DEL DESEMPEÑO DE LOS ENTRELAZADORES DE BITS DE BLOQUE, DORADO Y DORADO RELATIVO EN UN CANAL DE LÍNEA ELÉCTRICA DE BAJA TENSIÓN ANALYSIS OF THE PERFORMANCE OF THE INTERLEAVERS OF BLOCK, GOLDEN AND RELATIVE GOLDEN IN A OF LOW VOLTAGE POWER LINE CHANNEL

    Directory of Open Access Journals (Sweden)

    Washington Fernández R

    2008-09-01

    Full Text Available En este trabajo se analizan y se estudian tres tipos de entrelazadores de bit: bloque, dorado y dorado relativo, y se determina su desempeño en un canal de línea eléctrica de baja tensión. Se utiliza el modelo de ruido dado por Middleton, para la simulación del canal de línea eléctrica de baja tensión y el algoritmo que se utiliza para generar ruido gaussiano es el método de Box-Muller. Se compara el desempeño de los entrelazadores de bits de bloque, dorado y dorado relativo, en relación al largo de la palabra versus la razón de señal a ruido y bits erróneos por palabras versus la razón de señal a ruido. La codificación de línea que se utiliza es no retorno a cero. El entrelazador de bit dorado es el que tiene el mejor desempeño, por lo tanto, se puede emplear en la transmisión por línea eléctrica de baja tensión para disminuir los errores de bits consecutivos producido por el ruido impulsivo.This paper analyzes three types of interleavers: block, golden and golden relative to determine their performance in of low voltage power line channel. The model of noise given by Middleton is used for the simulation of the low voltage power line channel and the algorithm used to generate Gaussian noise is based on the Box-Muller method. The performance of interleavers block, golden and golden relative is compared in relationship to the length of the words versus the signal to noise ratio. The error bit by word versus signal to noise ratio is compared also. The codification of line used is no return to zero. It is concluded that the interleavers of golden has the best performance, thus it can be used in data transmission in low-voltage power line, reducing errors consecutive bits produced by impulse noise.

  13. Convergent modulation of singlet and triplet excited states of phosphine-oxide hosts through the management of molecular structure and functional-group linkages for low-voltage-driven electrophosphorescence.

    Science.gov (United States)

    Han, Chunmiao; Zhang, Zhensong; Xu, Hui; Xie, Guohua; Li, Jing; Zhao, Yi; Deng, Zhaopeng; Liu, Shiyong; Yan, Pengfei

    2013-01-02

    The controllable tuning of the excited states in a series of phosphine-oxide hosts (DPExPOCzn) was realized through introducing carbazolyl and diphenylphosphine-oxide (DPPO) moieties to adjust the frontier molecular orbitals, molecular rigidity, and the location of the triplet excited states by suppressing the intramolecular interplay of the combined multi-insulating and meso linkage. On increasing the number of substituents, simultaneous lowering of the first singlet energy levels (S(1)) and raising of the first triplet energy levels (T(1), about 3.0 eV) were achieved. The former change was mainly due to the contribution of the carbazolyl group to the HOMOs and the extended conjugation. The latter change was due to an enhanced molecular rigidity and the shift of the T(1) states from the diphenylether group to the carbazolyl moieties. This kind of convergent modulation of excited states not only facilitates the exothermic energy transfer to the dopants in phosphorescent organic light-emitting diodes (PHOLEDs), but also realizes the fine-tuning of electrical properties to achieve the balanced carrier injection and transportation in the emitting layers. As the result, the favorable performance of blue-light-emitting PHOLEDs was demonstrated, including much-lower driving voltages of 2.6 V for onset and 3.0 V at 100 cd m(-2), as well as a remarkably improved E.Q.E. of 12.6%. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Diagnosing in building main pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Telegin, L.G.; Gorelov, A.S.; Kurepin, B.N.; Orekhov, V.I.; Vasil' yev, G.G.; Yakovlev, Ye. I.

    1984-01-01

    General principles are examined for technical diagnosis in building main pipelines. A technique is presented for diagnosis during construction, as well as diagnosis of the technical state of the pipeline-construction machines and mechanisms. The survey materials could be used to set up construction of main pipelines.

  15. Maine Agricultural Foods. Project SEED.

    Science.gov (United States)

    Beaulieu, Peter; Ossenfort, Pat

    This paper describes an activity-based program that teaches students in grades 4-12 about the importance of Maine agriculture in their lives. Specifically, the goal is to increase student awareness of how the foods they eat are planted, harvested, and processed. The emphasis is on crops grown in Maine such as potatoes, broccoli, peas, blueberries,…

  16. Main Propulsion Test Article (MPTA)

    Science.gov (United States)

    Snoddy, Cynthia

    2010-01-01

    Scope: The Main Propulsion Test Article integrated the main propulsion subsystem with the clustered Space Shuttle Main Engines, the External Tank and associated GSE. The test program consisted of cryogenic tanking tests and short- and long duration static firings including gimbaling and throttling. The test program was conducted on the S1-C test stand (Position B-2) at the National Space Technology Laboratories (NSTL)/Stennis Space Center. 3 tanking tests and 20 hot fire tests conducted between December 21 1 1977 and December 17, 1980 Configuration: The main propulsion test article consisted of the three space shuttle main engines, flightweight external tank, flightweight aft fuselage, interface section and a boilerplate mid/fwd fuselage truss structure.

  17. Left main percutaneous coronary intervention.

    Science.gov (United States)

    Teirstein, Paul S; Price, Matthew J

    2012-10-23

    The introduction of drug-eluting stents and advances in catheter techniques have led to increasing acceptance of percutaneous coronary intervention (PCI) as a viable alternative to coronary artery bypass graft (CABG) for unprotected left main disease. Current guidelines state that it is reasonable to consider unprotected left main PCI in patients with low to intermediate anatomic complexity who are at increased surgical risk. Data from randomized trials involving patients who are candidates for either treatment strategy provide novel insight into the relative safety and efficacy of PCI for this lesion subset. Herein, we review the current data comparing PCI with CABG for left main disease, summarize recent guideline recommendations, and provide an update on technical considerations that may optimize clinical outcomes in left main PCI. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Main: FEB3 [TP Atlas

    Lifescience Database Archive (English)

    Full Text Available nt to sterilization and rinsing - One of the main components of biofilms is polysaccharides - Some pit-formi...ng bacteria such as Sphingomonas species A1 possess superchannels that directly incorporate and decompose polysaccharides - Detai...e entrance of the superchannel have been elucidated - We have obtained the crystals of ABC importer complexe...of water pipes and dental plaque are examples of biofilms. One of the main components of biofilms is polysac

  19. Decontamination of main coolant pumps

    International Nuclear Information System (INIS)

    Roofthooft, R.

    1988-01-01

    Last year a number of main coolant pumps in Belgian nuclear power plants were decontaminated. A new method has been developed to reduce the time taken for decontamination and the volume of waste to be treated. The method comprises two phases: Oxidation with permanganate in nitric acid and dissolution in oxalic acid. The decontamination of main coolant pumps can now be achieved in less than one day. The decontamination factors attained range between 15 and 150. (orig.) [de

  20. Harmonic current interaction at a low voltage customer's installations

    NARCIS (Netherlands)

    Bhattacharyya, S.; Myrzik, J.M.A.; Kling, W.L.; Cobben, J.F.G.; Casteren, van J.

    2009-01-01

    The increased uses of power electronics and switching devices in the electricity network have changed the operational environment of the power system. These devices have nonlinear voltage-current characteristics and produce harmonic currents, and consequently distort the voltage waveform. A low

  1. Impact Assessment of Electric Boilers in Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Sinha, Rakesh; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2018-01-01

    Flexibility from the electricity supply, with high share of intermittent energy sources such as wind and solar, has been offered by combined heat and power (CHP) generation in Denmark for decades. There could be periods where the fuel prices are higher than the electricity prices (even -ve), during...... high wind production and is idle for electric boilers (EBs) operation. In the future, using EBs, excess electricity from wind turbines can be effectively utilized for heat production, and still meet the thermal demand by decreasing CHP production. Thus, there is need for demand side flexibility...... control incorporated based on grid voltages, restricts the operation of EBs but ensures operation of the distribution system within limits still trying to keep the thermal comfort in the houses....

  2. Plastic Muscles TM as lightweight, low voltage actuators and sensors

    Science.gov (United States)

    Bennett, Matthew; Leo, Donald; Duncan, Andrew

    2008-03-01

    Using proprietary technology, Discover Technologies has developed ionomeric polymer transducers that are capable of long-term operation in air. These "Plastic Muscle TM" transducers are useful as soft distributed actuators and sensors and have a wide range of applications in the aerospace, robotics, automotive, electronics, and biomedical industries. Discover Technologies is developing novel fabrication methods that allow the Plastic Muscles TM to be manufactured on a commercial scale. The Plastic Muscle TM transducers are capable of generating more than 0.5% bending strain at a peak strain rate of over 0.1 %/s with a 3 V input. Because the Plastic Muscles TM use an ionic liquid as a replacement solvent for water, they are able to operate in air for long periods of time. Also, the Plastic Muscles TM do not exhibit the characteristic "back relaxation" phenomenon that is common in water-swollen devices. The elastic modulus of the Plastic Muscle TM transducers is estimated to be 200 MPa and the maximum generated stress is estimated to be 1 MPa. Based on these values, the maximum blocked force at the tip of a 6 mm wide, 35 mm long actuator is estimated to be 19 mN. Modeling of the step response with an exponential series reveals nonlinearity in the transducers' behavior.

  3. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based...

  4. Low voltage initiation of damaging arcs between electrical contacts

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1975-07-01

    Metallic arcs were found to precede the firm contacting of electrical contacts which were closed without bounce. When the open-circuit voltages were below the ionization potential, the initiation of these arcs was found to depend on the presence of asperities on the surfaces and on asperity contracting, melting, and pinching off by magnetic forces. The arc is thought to be initiated inductively when the molten metallic asperity contact is pinched off, and the electrode damage is similar to that produced by the arcing of opening contacts. Arcing could not be produced for exceptionally smooth surfaces, or, for rough surfaces when the open-circuit potential was below the melting voltages of the electrode metals. In order to prevent damage to contact surfaces by melting or arcing, it is suggested that test potentials be limited to below the melting voltages, that the current be limited, the test circuits be designed to prevent inductively generated high voltage transients, and the contact surfaces be very smooth. In order to facilitate arc initiation in arc welding applications, it is suggested that the surfaces of electrodes and work pieces be roughened. (U.S.)

  5. Modeling, Control and Protection of Low-Voltage DC Microgrids

    OpenAIRE

    Salomonsson, Daniel

    2008-01-01

    Current trends in electric power consumption indicate an increasing use of dc in end-user equipment, such as computers and other electronic appliances used in households and offices. With a dc power system, ac/dc conversion within these loads can be avoided, and losses reduced. AC/DC conversion is instead centralized, and by using efficient, fully controllable power-electronic interfaces, high power quality for both ac and dc systems during steady state and ac grid disturbances can be obtaine...

  6. Ceramic capacitor insulation resistance failures accelerated by low voltage

    Science.gov (United States)

    Brennan, T. F.

    1978-01-01

    Ceramic capacitors failed insulation resistance testing at less than one-tenth their rated voltage. Many failures recovered as the voltage was increased. Comprehensive failure analysis techniques, some of which are unprecedented, were used to examine these failures. It was determined that there was more than one failure mechanism, and the results indicate a need for special additional screening.

  7. Low voltage 80 KV to 125 KV electron processors

    International Nuclear Information System (INIS)

    Lauppi, U.V.

    1999-01-01

    The classic electron beam technology made use of accelerating energies in the voltage range of 300 to 800 kV. The first EB processors - built for the curing of coatings - operated at 300 kV. The products to be treated were thicker than a simple layer of coating with thicknesses up to 100g and more. It was only in the beginning of the 1970's that industrial EB processors with accelerating voltages below 300 kV appeared on the market. Our company developed the first commercial electron accelerator without a beam scanner. The new EB machine featured a linear cathode, emitting a shower or 'curtain' of electrons over the full width of the product. These units were much smaller than anv previous EB processors and dedicated to the curing of coatings and other thin layers. ESI's first EB units operated with accelerating voltages between 150 and 200 kV. In 1993 ESI announced the introduction of a new generation of Electrocure. EB processors operating at 120 kV, and in 1998, at the RadTech North America '98 Conference in Chicago, the introduction of an 80 kV electron beam processor under the designation Microbeam LV

  8. Low voltage varistor ceramics based on SnO2

    Indian Academy of Sciences (India)

    WINTEC

    School of Environmental and Chemical Engineering, Chonbuk National University, Jeonju 561-756, South Korea. † ... et al (2001) compared the grain boundary barrier proper- ... parameter, EB (breakdown voltage), was taken as the field.

  9. Room Temperature Anodization of Aluminum at Low Voltage

    International Nuclear Information System (INIS)

    Kamal, A.; Abdel-Karim, R.; El-Raghy, S.; EL-Sherif, R.M.; Wheed, A.

    2013-01-01

    Membranes with nanometer-scale features have many applications, such as in optics, electronics, catalysis, selective molecule separation, filtration and purification, bio sensing, and single-molecule detection. Anodization process was conducted using 15, 20, 30 and 35% by volume phosphoric acid. Results showed that Porous Anodized Aluminum (PAA) with ideal nano pore arrays can be fabricated at room temperature by one-step anodization on high purity aluminum foil at 5 V. Morphology of the PAA was characterized by scanning electron microscopy (SEM). The electrochemical behavior of anodized aluminum was studied in 0.1 M Na 2 SO 4 solutions using electrochemical impedance spectroscopy (EIS). The highest resistance of the porous layer (R p ) was detected for the samples anodized in 20% phosphoric acid

  10. Valuation of measurement data for low voltage network expansion planning

    NARCIS (Netherlands)

    Nijhuis, M.; Gibescu, M.; Cobben, J.F.G.

    2017-01-01

    The introduction of electric vehicles and photovoltaics is changing the residential electricity consumption. Distribution network operators (DNO) are investing in an advanced metering infrastructure (AMI) to enable cost reduction through smart grid applications. The DNO also benefits from the

  11. High Efficiency Power Converter for Low Voltage High Power Applications

    OpenAIRE

    Nymand, Morten; Andersen, Michael A. E.

    2010-01-01

    Emnet for denne Ph.d. afhandling er design af effektelektroniske dc-dc konvertere med meget høj virkningsgrad til anvendelser med høj udgangseffekt, lav indgangsspænding samt høj udgangsspænding. Disse konvertere anvendes i stigende grad indenfor vedvarende energisystemer baseret på brændselsceller, batterier eller solceller. Anvendelserne omfatter nødstrømsanlæg (UPS), decentrale mikro-kraftvarmeanlæg, transportsystemer så som elektriske hybridbiler, gaffeltrucks samt særlige anvendelser ind...

  12. Low voltage operating OFETs based on solution processed metal phthalocyanines

    Czech Academy of Sciences Publication Activity Database

    Chaidogiannos, G.; Petraki, F.; Glezos, N.; Kennou, S.; Nešpůrek, Stanislav

    2009-01-01

    Roč. 96, č. 3 (2009), s. 763-767 ISSN 0947-8396 R&D Projects: GA AV ČR KAN400720701 Institutional research plan: CEZ:AV0Z40500505 Keywords : field-effect transistors * thin-film transistors * copper phthalocyanine Subject RIV: CG - Electrochemistry Impact factor: 1.595, year: 2009

  13. Analysis of AC Low-Voltage Energy Harvesting

    Science.gov (United States)

    2014-09-01

    We have seen such efforts in car manufacturing, such as the Prius, that returns energy to the battery through the use of its regenerative brake ... system . Power electronics is the critical technology that makes harvesting this unused energy possible. Piezoelectricity is a material property that...Demo Circuit 1459b quick start guide [user’s guide]. Milpitas, CA: Linear Technology, April 2010. [13] Piezo Systems , “Piezoelectric Energy

  14. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, and remote power generation for light towers, camper vans, boats, beacons, and buoys etc. A review of current state-of-the-art is presented. The best performing converters achieve moderately high peak efficiencies at high input voltage and medium power level. However, system dimensioning and cost are often...

  15. Low-voltage grid-connection of photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Collinson, A.; Thornycroft, J.

    1999-07-01

    This report summarises the results of a project aimed at developing technical guidelines concerning grid connected photovoltaic (PV) inverter generators which are to be published in draft form as the {sup U}K Technical Guidelines for Inverter Connected Single Phase Photovoltaic (PV) Generators up to 5kVA{sup .} The background to the use of PV in the UK is traced, and the technical criteria for electrical integration of PV systems, and UK guidelines for grid connected PV systems are examined. The findings of the working group of the International Energy Agency (IEA) Implementing Agreement on Photovoltaic Power Systems are also presented in this report. Appendices discuss the UK technical guidelines, the IEA Task V activities,, utility aspects of grid-connected PV systems, and demonstration tests on grid-connected PV systems, and lists Task V reports.

  16. Unbalanced Voltage Compensation in Low Voltage Residential AC Grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design and test of a control algorithm for active front-end rectifiers that draw power from a residential AC grid to feed heat pump loads. The control algorithm is able to control the phase to neutral or phase to phase RMS voltages at the point of common coupling...

  17. Evolution of graphene nanoribbons under low-voltage electron irradiation

    KAUST Repository

    Zhu, Wenpeng; Wang, Hongtao; Yang, Wei

    2012-01-01

    Though the all-semiconducting nature of ultrathin graphene nanoribbons (GNRs) has been demonstrated in field-effect transistors operated at room temperature with ∼105 on-off current ratios, the borderline for the potential of GNRs

  18. Low-Voltage Paper Isotachophoresis Device for DNA Focusing

    Science.gov (United States)

    Li, Xiang; Luo, Long; Crooks, Richard M.

    2015-01-01

    We present a new paper-based isotachophoresis (ITP) device design for focusing DNA samples having lengths ranging from 23 to at least 1517 bp. DNA is concentrated by more than two orders of magnitude within 4 min. The key component of this device is a 2 mm-long, 2 mm-wide circular paper channel formed by concertina folding a paper strip and aligning the circular paper zones on each layer. Due to the short channel length, a high electric field of ~16 kV/m is easily generated in the paper channel using two 9 V batteries. The multilayer architecture also enables convenient reclamation and analysis of the sample after ITP focusing by simply opening the origami paper and cutting out the desired layers. We profiled the electric field in the origami paper channel during ITP experiments using a nonfocusing fluorescent tracer. The result showed that focusing relies on formation and subsequent movement of a sharp electric field boundary between the leading and trailing electrolyte. PMID:26338530

  19. Reliable and Low-Voltage Electrowetting on Thin Parylene Films

    NARCIS (Netherlands)

    Dhindsa, M.S.; Kuiper, S.; Kumar, R.; Heikenfeld, J.

    2011-01-01

    The stability of an electrowetting system is dependent upon the choice of liquids, the dielectric material and the operating voltage.Substantial progress is reported herein on use of 300 nm thick poly-tetrafluoro-para-xylylene) (Parylene HT) films for almost 100° of reliable electrowetting

  20. Low Voltage Current Mode Switched-Current-Mirror Mixer

    Directory of Open Access Journals (Sweden)

    Chunhua Wang

    2009-09-01

    Full Text Available A new CMOS active mixer topology can operate at 1 V supply voltage by use of SCM (switched currentmirror. Such current-mode mixer requires less voltage headroom with good linearization. Mixing is achieved with four improved current mirrors, which are alternatively activated. For ideal switching, the operation is equivalent to a conventional active mixer. This paper analyzes the performance of the SCM mixer, in comparison with the conventional mixer, demonstrating competitive performance at a lower supply voltage. Moreover, the new mixer’s die, without any passive components, is very small, and the conversion gain is easy to adjust. An experimental prototype was designed and simulated in standard chartered 0.18μm RF CMOS Process with Spectre in Cadence Design Systems. Experimental results show satisfactory mixer performance at 2.4 GHz.

  1. New Main Ring control system

    International Nuclear Information System (INIS)

    Seino, K.; Anderson, L.; Ducar, R.; Franck, A.; Gomilar, J.; Hendricks, B.; Smedinghoff, J.

    1990-03-01

    The Fermilab Main Ring control system has been operational for over sixteen years. Aging and obsolescence of the equipment make the maintenance difficult. Since the advent of the Tevatron, considerable upgrades have been made to the controls of all the Fermilab accelerators except the Main Ring. Modernization of the equipment and standardization of the hardware and software have thus become inevitable. The Tevatron CAMAC serial system has been chosen as a basic foundation in order to make the Main Ring control system compatible with the rest of the accelerator complex. New hardware pieces including intelligent CAMAC modules have been designed to satisfy unique requirements. Fiber optic cable and repeaters have been installed in order to accommodate new channel requirements onto the already saturated communication medium system. 8 refs., 2 figs

  2. Main: FBB2 [TP Atlas

    Lifescience Database Archive (English)

    Full Text Available ion of the c-ring - A subunit packing model of E. coli c-ring has been proposed - The main chain secondary s...tructure of thermophile c-ring has been obtained ATP synthase is a general term for an enzyme that can synth

  3. Main: FEA5 [TP Atlas

    Lifescience Database Archive (English)

    Full Text Available al or an anti-cancer drug, is the main cause of hospital-acquired infection - Dru...e will elucidate the entire structure of the transport machinery in action to understand its functions in detail. FEA5.csml ...

  4. Residential Energy Efficiency Potential: Maine

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    Energy used by Maine single-family homes that can be saved through cost-effective improvements. Prepared by Eric Wilson and Noel Merket, NREL, and Erin Boyd, U.S. Department of Energy Office of Energy Policy and Systems Analysis.

  5. CENTRE OF THE MAIN INTERESTS

    Directory of Open Access Journals (Sweden)

    DIANA DELEANU

    2013-05-01

    Full Text Available The centre of the main interests of the debtor is a legal tool meant to settle conflicts that can arise between jurisdictions in cross-border insolvencies, based on the principles of mutual recognition and co-operation.

  6. ONKALO - Main drawings in 2007

    International Nuclear Information System (INIS)

    2008-05-01

    The first overall site characterisation programme for a Finnish repository of spent nuclear fuel was introduced in 1982. This programme already suggested that the site confirmation for a detailed repository design and safety assessment should include characterisation performed in an underground rock characterisation facility (URCF). This idea was confirmed during the detailed site characterisation. International views have also emphasised the importance of underground characterisation before the final decision to construct the repository is taken. The underground rock characterisation facility (ONKALO) is excavated at Olkiluoto in the municipality of Eurajoki. ONKALO should be constructed to allow characterisation work for site confirmation without jeopardising long-term safety of the repository site. It should also be possible to link ONKALO later to the repository as to a part of it. The construction of ONKALO was started in 2004 and will be completed in 2014. The characterisation work has started in ONKALO and will focus on the disposal depth. In the main drawings stage, ONKALO was described at the level of detail needed for a construction permit in 2003. This meant description of the location, final structures and final systems. This summary report describes the development of design to updated main drawings in 2007 at the same level of detail (no temporary arrangements are described). The main changes are the added exhaust air shaft and advancing the controlled area's inlet air shaft to the ONKALO phase. Also the layout and the depth of the characterisation levels have been updated according to the current bedrock information. Some buildings on the surface will house sets of equipment directly connected with underground facility and this equipment is described in this report. No buildings or other equipment are described in this report, because they are not directly connected with the underground facility. The main element of ONKALO is a system of

  7. A main sequence for quasars

    Science.gov (United States)

    Marziani, Paola; Dultzin, Deborah; Sulentic, Jack W.; Del Olmo, Ascensión; Negrete, C. A.; Martínez-Aldama, Mary L.; D'Onofrio, Mauro; Bon, Edi; Bon, Natasa; Stirpe, Giovanna M.

    2018-03-01

    The last 25 years saw a major step forward in the analysis of optical and UV spectroscopic data of large quasar samples. Multivariate statistical approaches have led to the definition of systematic trends in observational properties that are the basis of physical and dynamical modeling of quasar structure. We discuss the empirical correlates of the so-called “main sequence” associated with the quasar Eigenvector 1, its governing physical parameters and several implications on our view of the quasar structure, as well as some luminosity effects associated with the virialized component of the line emitting regions. We also briefly discuss quasars in a segment of the main sequence that includes the strongest FeII emitters. These sources show a small dispersion around a well-defined Eddington ratio value, a property which makes them potential Eddington standard candles.

  8. A Main Sequence for Quasars

    Directory of Open Access Journals (Sweden)

    Paola Marziani

    2018-03-01

    Full Text Available The last 25 years saw a major step forward in the analysis of optical and UV spectroscopic data of large quasar samples. Multivariate statistical approaches have led to the definition of systematic trends in observational properties that are the basis of physical and dynamical modeling of quasar structure. We discuss the empirical correlates of the so-called “main sequence” associated with the quasar Eigenvector 1, its governing physical parameters and several implications on our view of the quasar structure, as well as some luminosity effects associated with the virialized component of the line emitting regions. We also briefly discuss quasars in a segment of the main sequence that includes the strongest FeII emitters. These sources show a small dispersion around a well-defined Eddington ratio value, a property which makes them potential Eddington standard candles.

  9. At ISR Main Control Room

    CERN Multimedia

    1983-01-01

    After 13 years the exploitation of the Intersecting Storage Rings as a beam-beam collider went to an end. In this last year the demands were very exacting, both in terms of operating time and diversified running conditions (Annual Report 1983 p. 123). Before dismantelement the photographer made a last tour, see photos 8310889X --> 8310667X. This photo shows the Main Control Room.

  10. JWST-MIRI spectrometer main optics design and main results

    Science.gov (United States)

    Navarro, Ramón; Schoenmaker, Ton; Kroes, Gabby; Oudenhuysen, Ad; Jager, Rieks; Venema, Lars

    2017-11-01

    MIRI ('Mid InfraRed Instrument') is the combined imager and integral field spectrometer for the 5-29 micron wavelength range under development for the James Webb Space Telescope JWST. The flight acceptance tests of the Spectrometer Main Optics flight models (SMO), part of the MIRI spectrometer, are completed in the summer of 2008 and the system is delivered to the MIRI-JWST consortium. The two SMO arms contain 14 mirrors and form the MIRI optical system together with 12 selectable gratings on grating wheels. The entire system operates at a temperature of 7 Kelvin and is designed on the basis of a 'no adjustments' philosophy. This means that the optical alignment precision depends strongly on the design, tolerance analysis and detailed knowledge of the manufacturing process. Because in principle no corrections are needed after assembly, continuous tracking of the alignment performance during the design and manufacturing phases is important. The flight hardware is inspected with respect to performance parameters like alignment and image quality. The stability of these parameters is investigated after exposure to various vibration levels and successive cryogenic cool downs. This paper describes the philosophy behind the acceptance tests, the chosen test strategy and reports the results of these tests. In addition the paper covers the design of the optical test setup, focusing on the simulation of the optical interfaces of the SMO. Also the relation to the SMO qualification and verification program is addressed.

  11. Main ring transition crossing simulations

    International Nuclear Information System (INIS)

    Kourbanis, I.; Ng, King-Yuen.

    1990-10-01

    We used ESME to simulate transition crossing in the Main Ring (MR). For the simulations, we followed the MR 29 cycle used currently for bar p production with a flat top of 120 GeV. In Sect. II, some inputs are discussed. In Sect. III, we present simulations with space charge turned off so that the effect of nonlinearity can be studied independently. When space charge is turned on in Sect. IV, we are faced with the problem of statistical errors due to binning, an analysis of which is given in the Appendices. Finally in Sects. V and VI, the results of simulations with space charge are presented and compared with the experimental measurements. 7 refs., 6 figs

  12. Improvement of main control room

    International Nuclear Information System (INIS)

    Chae, Sung Ki; Ham, Chang Sik; Kwon, Ki Chun

    1991-07-01

    Information display system, advanced alarm system and fiber optical communication system were developed to improve the main control room in nuclear power plant. Establishing the new hierachical information structure of plant operation data, plant overview status board(POSB) and digital indicator(DI) were designed and manufactured. The prototype advanced alarm system which employed the new alarm logics and algorithm compared with the conventional alarm system were developed and its effectiveness was proved. Optical communication system which has multi-drop feature and capability of upgrading to large-scale system by using BITBUS communication protocol which is proven technology, were developed. Reliability of that system was enhanced by using distributed control. (Author)

  13. The role of Main Institutions

    DEFF Research Database (Denmark)

    Persson, H Thomas R; Chabanet, Didier; Rakar, Fredrik

    2017-01-01

    ), in many countries the need emerged to understand the best methods to promote their establishment and continued success. In order to understand these issues, to contribute to the academic debate on SEs and to give useful policy advice on a truly enabling ecosystem, in November 2013 a consortium of 11...... Entrepreneurship”; to identify the “New Generation” of Social Entrepreneurs; to build an “Evolutionary Theory of Social Entrepreneurship”; to provide effective policy advices to stakeholders. In order to pursue and achieve these research objectives, the consortium implemented a complex research design...... in the social economy; - In the fifth chapter the authors address the role of the main institutions in developing (or hindering) social enterprises; - In the sixth chapter, stakeholder network maps are used to identify four ‘ecosystem types’ across the 10 partner countries; - The seventh chapter gives...

  14. Main injector synchronous timing system

    International Nuclear Information System (INIS)

    Blokland, W.; Steimel, J.

    1998-01-01

    The Synchronous Timing System is designed to provide sub-nanosecond timing to instrumentation during the acceleration of particles in the Main Injector. Increased energy of the beam particles leads to a small but significant increase in speed, reducing the time it takes to complete a full turn of the ring by 61 nanoseconds (or more than 3 rf buckets). In contrast, the reference signal, used to trigger instrumentation and transmitted over a cable, has a constant group delay. This difference leads to a phase slip during the ramp and prevents instrumentation such as dampers from properly operating without additional measures. The Synchronous Timing System corrects for this phase slip as well as signal propagation time changes due to temperature variations. A module at the LLRF system uses a 1.2 Gbit/s G-Link chip to transmit the rf clock and digital data (e.g. the current frequency) over a single mode fiber around the ring. Fiber optic couplers at service buildings split off part of this signal for a local module which reconstructs a synchronous beam reference signal. This paper describes the background, design and expected performance of the Synchronous Timing System. copyright 1998 American Institute of Physics

  15. Main injector synchronous timing system

    International Nuclear Information System (INIS)

    Blokland, Willem; Steimel, James

    1998-01-01

    The Synchronous Timing System is designed to provide sub-nanosecond timing to instrumentation during the acceleration of particles in the Main Injector. Increased energy of the beam particles leads to a small but significant increase in speed, reducing the time it takes to complete a full turn of the ring by 61 nanoseconds (or more than 3 rf buckets). In contrast, the reference signal, used to trigger instrumentation and transmitted over a cable, has a constant group delay. This difference leads to a phase slip during the ramp and prevents instrumentation such as dampers from properly operating without additional measures. The Synchronous Timing System corrects for this phase slip as well as signal propagation time changes due to temperature variations. A module at the LLRF system uses a 1.2 Gbit/s G-Link chip to transmit the rf clock and digital data (e.g. the current frequency) over a single mode fiber around the ring. Fiber optic couplers at service buildings split off part of this signal for a local module which reconstructs a synchronous beam reference signal. This paper describes the background, design and expected performance of the Synchronous Timing System

  16. Main technical topics in 1999

    International Nuclear Information System (INIS)

    2000-01-01

    This Safety Authority annual report strives to present current organizational provisions and future trends in nuclear safety supervision in France and to describe the most outstanding occurrences during the past year. A first part presents nine documents concerning the main topics of 1999: aging of nuclear installations, the Offsite Emergency Plans (PPI), the impact of nuclear activities on man and the environment, the criticality hazards, EDF in 1999, the EPR project, the Andra in 1999, the transport incidents, the nuclear safety in eastern Europe. The second part presents the missions and actions of the Nuclear Installations Safety in the domains of the liabilities, the organization of the nuclear safety control, the regulations of the INB, the public information, the international relations, the crisis management, the radioactive materials transportation, the radioactive wastes. The equipment, the radiation protection and the exploitation of the pressurized water reactors are also treated just as the experimental reactors, the fuel cycle installations and the the nuclear installations dismantling. (A.L.B.)

  17. Main challenges of residential areas

    Directory of Open Access Journals (Sweden)

    Oana Luca

    2017-06-01

    Full Text Available The present article is a position paper aiming to initiate a professional debate related to the aspects related to the urban dysfunctions leading to the wear of the residential areas. The paper proposes a definition of the wear process, identify the main causes leading to its occurrence and propose a number of solutions to neutralise the dysfunctions. The three wearing phases of residential areas components are emphasized, exploring their lifecycle. In order to perform the study of urban wear, the status of the residential areas components can be established and monitored, and also the variables of the function that can mathematically model the specific wear process may be considered. The paper is considered a first step for the model adjustment, to be tested and validated in the following steps. Based on the mathematical method and model, there can be created, in a potential future research, the possibility of determining the precarity degree for residential areas/neighbourhoods and cities, by minimising the subjective component of the analyses preceding the decision for renovation or regeneration.

  18. Research in auditing: main themes

    Directory of Open Access Journals (Sweden)

    Marcelo Porte

    Full Text Available ABSTRACT The passage of the Sarbanes-Oxley Act (SOX was a turning point in auditing and in auditors practice for the academic world. Research concerning the characterization of academic production related to auditing is in its third decade. Its analysis is accomplished by means of definition of keywords, abstracts or title, and information on thematic association within the academic production itself in auditing is undisclosed. In order to revise this gap in auditing literature, this study identified the main themes in auditing and their association in post-SOX era by analyzing the content of objectives and hypothesis of 1,650 publications in Web of Science (2002-2014. The findings in this study extended those from the study by Lesage and Wechtler (2012 from 16 auditing thematic typologies to 22. The results demonstrate that the themes audit report & financial statement users, corporate governance, audit market, external audit, socio-economic data of the company, international regulation, and fraud risk & audit risk were the most addressed in the publications about auditing. Corporate governance has a broader association with the other themes in the area. Future researches may use these themes and relate them to the methodologies applied to audit studies.

  19. Tinkering at the main-ring lattice

    Energy Technology Data Exchange (ETDEWEB)

    Ohnuma, S.

    1982-08-23

    To improve production of usable antiprotons using the proton beam from the main ring and the lossless injection of cooled antiprotons into the main ring, modifications of the main ring lattice are recommended.

  20. Reliability Analysis of Differential Relay as Main Protection Transformer Using Fuzzy Logic Algorithm

    Science.gov (United States)

    Mulyadi, Y.; Sucita, T.; Sumarto; Alpani, M.

    2018-02-01

    Electricity supply demand is increasing every year. It makes PT. PLN (Persero) is required to provide optimal customer service and satisfaction. Optimal service depends on the performance of the equipment of the power system owned, especially the transformer. Power transformer is an electrical equipment that transforms electricity from high voltage to low voltage or vice versa. However, in the electrical power system, is inseparable from interference included in the transformer. But, the disturbance can be minimized by the protection system. The main protection transformer is differential relays. Differential relays working system using Kirchoff law where inflows equal outflows. If there are excessive currents that interfere then the relays will work. But, the relay can also experience decreased performance. Therefore, this final project aims to analyze the reliability of the differential relay on the transformer in three different substations. Referring to the standard applied by the transmission line protection officer, the differential relay shall have slope characteristics of 30% in the first slope and 80% in the second slope when using two slopes and 80% when using one slope with an instant time and the corresponding ratio. So, the results obtained on the Siemens differential release have a reliable slope characteristic with a value of 30 on the fuzzy logic system. In a while, ABB a differential relay is only 80% reliable because two experiments are not reliable. For the time, all the differential relays are instant with a value of 0.06 on the fuzzy logic system. For ratios, the differential relays ABB have a better value than others brand with a value of 151 on the fuzzy logic system.

  1. 75 FR 27863 - Savings Bank of Maine, MHC and Savings Bank of Maine, Gardiner, Maine; Approval of Conversion...

    Science.gov (United States)

    2010-05-18

    ... DEPARTMENT OF THE TREASURY Office of Thrift Supervision [AC-38: OTS Nos. 06947 and H 4709] Savings Bank of Maine, MHC and Savings Bank of Maine, Gardiner, Maine; Approval of Conversion Application Notice is hereby given that on May 7, 2010, the Office of Thrift Supervision approved the application of...

  2. 30 CFR 57.6160 - Main facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main facilities. 57.6160 Section 57.6160...-Underground Only § 57.6160 Main facilities. (a) Main facilities used to store explosive material underground... facilities will not prevent escape from the mine, or cause detonation of the contents of another storage...

  3. Isolators Including Main Spring Linear Guide Systems

    Science.gov (United States)

    Goold, Ryan (Inventor); Buchele, Paul (Inventor); Hindle, Timothy (Inventor); Ruebsamen, Dale Thomas (Inventor)

    2017-01-01

    Embodiments of isolators, such as three parameter isolators, including a main spring linear guide system are provided. In one embodiment, the isolator includes first and second opposing end portions, a main spring mechanically coupled between the first and second end portions, and a linear guide system extending from the first end portion, across the main spring, and toward the second end portion. The linear guide system expands and contracts in conjunction with deflection of the main spring along the working axis, while restricting displacement and rotation of the main spring along first and second axes orthogonal to the working axis.

  4. Main approaches to the study of loss

    Directory of Open Access Journals (Sweden)

    Burina E. A.

    2016-07-01

    Full Text Available this article presents the main approaches to the concepts of grief and loss study. The article describes the contribution of E. Lindemann, Z. Freud, J. Bowlby, F.E. Vasiluk, and E. Kubler-Ross. The research also contains the main forms of grief and some stadial models within the scope of problematics.

  5. Nitrogen chronology of massive main sequence stars

    NARCIS (Netherlands)

    Köhler, K.; Borzyszkowski, M.; Brott, I.; Langer, N.; de Koter, A.

    2012-01-01

    Context. Rotational mixing in massive main sequence stars is predicted to monotonically increase their surface nitrogen abundance with time. Aims. We use this effect to design a method for constraining the age and the inclination angle of massive main sequence stars, given their observed luminosity,

  6. Engineering Design of KSTAR tokamak main structure

    International Nuclear Information System (INIS)

    Im, K.H.; Cho, S.; Her, N.I.

    2001-01-01

    The main components of the KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak including vacuum vessel, plasma facing components, cryostat, thermal shield and magnet supporting structure are in the final stage of engineering design. Hundai Heavy Industries (HHI) has been involved in the engineering design of these components. The current configuration and the final engineering design results for the KSTAR main structure are presented. (author)

  7. Riigikogu maine ja armastus / Aune Past

    Index Scriptorium Estoniae

    Past, Aune, 1954-

    2007-01-01

    Autor arutleb Riigikogu maine üle, toetudes TÜ ajakirjanduse ja kommunikatsiooni osakonna 2007. aastal tehtud uuringu tulemustele. Riigikogu liikmete maine paraneks, kui neil endil oleks selge, mis eesmärgil Toompeale mindi ja sellest siis ka rahvale kõneldaks

  8. Hillshades for the main 8 Hawaiian Islands

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These hillshade datasets were derived from USGS 7.5' DEM Quads for the main 8 Hawaiian Islands. Individual DEM quads were first converted to a common datum, and...

  9. Nuclear power station main control room habitability

    International Nuclear Information System (INIS)

    Paschal, W.B.; Knous, W.S.

    1989-01-01

    The main control room at a nuclear power station must remain habitable during a variety of plant conditions and postulated events. The control room habitability requirement and the function of the heating, ventilating, air-conditioning, and air treatment system are to control environmental factors, such as temperature, pressure, humidity, radiation, and toxic gas. Habitability requirements provide for the safety of personnel and enable operation of equipment required to function in the main control room. Habitability as an issue has been gaining prominence with the Advisor Committee of Reactor Safeguards and the Nuclear Regulatory Commission since the incident at Three Mile Island. Their concern is the ability of the presently installed habitability systems to control the main control room environment after an accident. This paper discusses main control room HVAC systems; the concern, requirements, and results of NRC surveys and notices; and an approach to control room habitability reviews

  10. Seasonal Composite Chlorophyll Concentrations - Gulf of Maine

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This personal geodatabase contains raster images of chlorophyll concentrations in the Gulf of Maine. These raster images are seasonal composites, and were calculated...

  11. Collins' bypass for the main ring

    International Nuclear Information System (INIS)

    Ohnuma, S.

    1982-01-01

    Design of the bypass for the main ring at Fermilab is discussed. Specific design features discussed include space, path length, geometric closure, matching of betatron functions, and external dispersion. Bypass parameters are given

  12. Monthly Composite Chlorophyll Concentrations - Gulf of Maine

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This personal geodatabase contains raster images of chlorophyll concentrations in the Gulf of Maine. These raster images are monthly composites, and were calculated...

  13. 2015 City of Portland, Maine, Lidar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — 2015 City of Portland Maine Lidar Data Acquisition and Processing Woolpert Order No. 75564 Contractor: Woolpert, Inc. This task is for a high resolution data set of...

  14. 2016 USGS Lidar DEM: Maine QL2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Product: These are Digital Elevation Model (DEM) data for Franklin, Oxford, Piscataquis, and Somerset Counties, Maine as part of the required deliverables for the...

  15. Molecular clusters of the main group elements

    CERN Document Server

    Driess, Matthias

    2008-01-01

    ""To summarize, Molecular Clusters of the Main Group Elements is certainly not a popular science book, nor is it a textbook; it is a very good, up-to-date collection of articles for the specialist. Als Fazit bleibt: Molecular Clusters of the Main Group Elements ist sicher kein populissenschaftliches Werk, auch kein Lehrbuch, aber eine gelungene, hoch aktuelle Zusammenstellung fen interessierten Fachmann."" -Michael Ruck, TU Dresden, Angewandte Chemie, 2004 - 116/36 + International Edition 2004 - 43/36

  16. Revisiting Reuse in Main Memory Database Systems

    OpenAIRE

    Dursun, Kayhan; Binnig, Carsten; Cetintemel, Ugur; Kraska, Tim

    2016-01-01

    Reusing intermediates in databases to speed-up analytical query processing has been studied in the past. Existing solutions typically require intermediate results of individual operators to be materialized into temporary tables to be considered for reuse in subsequent queries. However, these approaches are fundamentally ill-suited for use in modern main memory databases. The reason is that modern main memory DBMSs are typically limited by the bandwidth of the memory bus, thus query execution ...

  17. Main building fire drill safely concluded

    CERN Document Server

    CERN Bulletin

    2015-01-01

    Last week, a simulated fire in the stairwell of the Main Building put CERN’s emergency response procedures to the test.   Firefighters descend the stairwell in the Main Building as the simulated fire rises.   At 2 p.m. on 22 September, alarms sounded around CERN’s Main Building as an evacuation exercise got underway. A simulated fire in the  stairwell, complete with very realistic smoke, led to the evacuation of one of the busiest places at CERN. The Main Building complex includes the Carlson Wagonlit travel agency, the post office, UBS, Uniqa, the Users Office, the Staff Association and the Novae restaurant as well as the Main Auditorium, the Council Chamber and the Charpak meeting room. It was impressive to see how quickly the smoke propagated in the staircase as well as into the corridors, and equally impressive to see how smoothly, quickly and efficiently the evacuation proceeded. The...

  18. Guide to the Main Ring DO overpass

    International Nuclear Information System (INIS)

    Turkot, F.

    1985-01-01

    The DO overpass is a modification of the beam orbit in Main Ring in order to better accommodate a Tevatron collider detector at DO. The orbit is moved up approx. 51 inches over most of the long straight section at DO, thus making the Main Ring the world's first non-planar proton synchrotron. A similar overpass, but with four times the displacement, is planned for the CDF detector at the BO straight section. The nominal separation between the beam orbit in the Main Ring and the orbit in the Tevatron is 25.5 inches. Early in the design study of a detector that would utilize the Tevatron is a anti pp collider, it was apparent that a larger separation at the detector was highly desirable. In 1981, Tom Collins proposed a specific lattice geometry in the Main Ring for achieving larger separation, called ''the screw beam''. His proposal has served as the basis for the design of both the BO and DO overpasses. The main purpose of this report is to describe in some detail the implementation of the DO overpass. Topics to be covered include: (a) geometry of the overpass orbit, (b) the new hardware in the tunnel, (c) the power supply system, (d) the control facility, (e) accelerator beam dynamics ramifications, and (f) commissioning experience. A secondary purpose is to provide a fairly complete ''bibliography'' to the sources of information on the overpass. 17 refs., 17 figs

  19. Main Coast Winds - Final Scientific Report

    Energy Technology Data Exchange (ETDEWEB)

    Jason Huckaby; Harley Lee

    2006-03-15

    The Maine Coast Wind Project was developed to investigate the cost-effectiveness of small, distributed wind systems on coastal sites in Maine. The restructuring of Maine's electric grid to support net metering allowed for the installation of small wind installations across the state (up to 100kW). The study performed adds insight to the difficulties of developing cost-effective distributed systems in coastal environments. The technical hurdles encountered with the chosen wind turbine, combined with the lower than expected wind speeds, did not provide a cost-effective return to make a distributed wind program economically feasible. While the turbine was accepted within the community, the low availability has been a negative.

  20. Space Shuttle main engine product improvement

    Science.gov (United States)

    Lucci, A. D.; Klatt, F. P.

    1985-01-01

    The current design of the Space Shuttle Main Engine has passed 11 certification cycles, amassed approximately a quarter million seconds of engine test time in 1200 tests and successfully launched the Space Shuttle 17 times of 51 engine launches through May 1985. Building on this extensive background, two development programs are underway at Rocketdyne to improve the flow of hot gas through the powerhead and evaluate the changes to increase the performance margins in the engine. These two programs, called Phase II+ and Technology Test Bed Precursor program are described. Phase II+ develops a two-tube hot-gas manifold that improves the component environment. The Precursor program will evaluate a larger throat main combustion chamber, conduct combustion stability testing of a baffleless main injector, fabricate an experimental weld-free heat exchanger tube, fabricate and test a high pressure oxidizer turbopump with an improved inlet, and develop and test methods for reducing temperature transients at start and shutdown.

  1. Transition crossing in the main injector

    International Nuclear Information System (INIS)

    Wei, J.

    1990-01-01

    This report summarizes the study of various longitudinal problems pertaining to the transition-energy crossing in the proposed Fermi Lab Main Injector. The theory indicates that the beam loss and bunch-area growth are mainly caused by the chromatic non-linear effect, which is enhanced by the space-charge force near transition. Computer simulation using the program TIBETAN shows that a ''γ T jump'' of about 1.5 unit within 1 ms is adequate to achieve a ''clean'' crossing in the currently proposed h=588 scenario. 19 refs., 4 figs

  2. The Fermilab Main Injector Technical Design Handbook

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    1994-08-01

    This report contains a description of the design, cost estimate, and construction schedule of the Fermilab Main Injector (FMI) Project. The technical, cost, and schedule baselines for the FMI Project have already been established and may be found in the Fermilab Main Injector Title I Design Report, issued in August 1992. This report updates and expands upon the design and schedule for construction of all subsystem components and associated civil construction described in the Title I Design Report. The facilities described have been designed in conformance with DOE 6430.1A, "United States Department of Energy General Design Criteria."

  3. Current Russian patriotism: matter, features, main directions

    Directory of Open Access Journals (Sweden)

    Lutovinov Vladimir Ilich

    2013-11-01

    Full Text Available The article considers understanding and the main point of patriotism as one of high cultural values. The main approaches that reveal different sides of this phenomenon, its role and importance in a history of Russia in the 21st century are inferred from the analysis of viewpoints of Russian thinkers and contemporary researchers. The patriotism formation problems in Russian society and their condition are defined, the need of patriotic level rise as one of the conditions for great Russia rebirth is substantiated.

  4. Bunch coalescing in the Fermilab Main Ring

    International Nuclear Information System (INIS)

    Wildman, D.; Martin, P.; Meisner, K.; Miller, H.W.

    1987-01-01

    A new RF system has been installed in the Fermilab Main Ring to coalesce up to 13 individual bunches of protons or antiprotons into a single high-intensity bunch. The coalescing process consists of adiabatically reducing the h=1113 Main Ring RF voltage from 1 MV to less than 1 kV, capturing the debunched beam in a linearized h=53 and h=106 bucket, rotating for a quarter of a synchrotron oscillation period, and then recapturing the beam in a single h=1113 bucket. The new system is described and the results of recent coalescing experiments are compared with computer-generated particle tracking simulations

  5. Main principles of development stationary training facilities

    International Nuclear Information System (INIS)

    Tsiptsyura, R.D.

    1986-01-01

    The designation of stationary training facilities is shown and the main requirements for them are formulated. When considering the above-mentioned requirements, special attention was paid to obligatory correspondence between training experience and practical skill of an operator. It is shown, that the switchboard block is the major unit of the training facility, which should develop skills and habits of an operator

  6. Live insertion method used for main renewal

    International Nuclear Information System (INIS)

    Solkowitz, M.

    1992-01-01

    Baltimore Gas and Electric's pilot project using the live insertion method to replace a cast iron main provided excellent results. Its use on Eastern Avenue, a major state highway, was cost effective, provided gas service to customers during the work, required relatively short construction time and resulted in only minor traffic disruptions. Gas service transfers to the new main were done at customer convenience and resulted in outages of only a few hours per customer. This paper reports that the project involved inserting a 6-in. plastic line inside an existing 10-in. cast iron main. Miller Pipeline Corp., Indianapolis, supplier of the Insertec left-angle R right-angle live insertion method was contracted for the job. Miller technicians assisted BG and E forces by providing a load analysis of the main, a pushing machine and related supplies, foaming equipment and pipe cutting tools. Company forces were responsible for all preparatory work, including opening all excavations, installing bypasses, and fusing and testing the plastic pipe. Service transfers and renewals were also completed by company employees

  7. Maine Project against Bullying. Final Report.

    Science.gov (United States)

    Saufler, Chuck; Gagne, Cyndi

    Noting that bullying among primary school-age children has become recognized as an antecedent to more violent behavior in later grades, the 3-year Maine Project Against Bullying examined currently available research on bullying and evaluated books, curricula, media materials, and programs to identify resources and strategies which can be applied…

  8. Modern Portfolio Theory: Some Main Results

    OpenAIRE

    Müller, Heinz H.

    2017-01-01

    This article summarizes some main results in modern portfolio theory. First, the Markowitz approach is presented. Then the capital asset pricing model is derived and its empirical testability is discussed. Afterwards Neumann-Morgenstern utility theory is applied to the portfolio problem. Finally, it is shown how optimal risk allocation in an economy may lead to portfolio insurance

  9. Enhancing training in the main control room

    International Nuclear Information System (INIS)

    McGuigan, K.; O'Leary, K.; Canavan, K.

    2004-01-01

    In 2003 Pickering B Nuclear of Ontario Power Generation installed a Desktop Simulator (DTS) in the Main Control Room (MCR) for training purposes. This paper will outline why this training enhancement was undertaken and the approach taken to secure its use in an active MCR environment while minimizing distractions to plant operations. (author)

  10. Main successes, achievements. Paths of development

    Directory of Open Access Journals (Sweden)

    A. A. Kubanova

    2015-01-01

    Full Text Available The article provides the overview of incidence of sexually transmitted infections and skin disorders over time in Russian Federation in 2004-2014 with its main positive tendencies; results of reorganisation of bed capacity of dermatovenerologic medical organizations; dermatovenerologic bed rates.

  11. Main facts 1995; Faits marquants 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    This report presents the main facts of the studies carried out by the Direction des Etudes et Recherches (DER) of Electricite de France: new applications of electricity, classical and nuclear thermal power plants, electrical equipment, environment protection, monitoring and plants operations.

  12. Space transportation main engine reliability and safety

    Science.gov (United States)

    Monk, Jan C.

    1991-01-01

    Viewgraphs are used to illustrate the reliability engineering and aerospace safety of the Space Transportation Main Engine (STME). A technology developed is called Total Quality Management (TQM). The goal is to develop a robust design. Reducing process variability produces a product with improved reliability and safety. Some engine system design characteristics are identified which improves reliability.

  13. Water Hammer in Pumped Sewer Mains

    DEFF Research Database (Denmark)

    Larsen, Torben

    This publication is intended for engineers seeking an introduction to the problem of water hammer in pumped pressure mains. This is a subject of increasing interest because of the development of larger and more integrated sewer systems. Consideration of water hammer is essential for structural...

  14. D.E.R. 91 main facts

    International Nuclear Information System (INIS)

    Schmidt, N.

    1991-01-01

    This report presents the main facts of the studies carried out by the Direction des Etudes et Recherches (DER) of Electricite de France: New applications of electricity, classical and nuclear thermal power plants, electrical equipment, environment protection, network analysis, information and informatic equipment

  15. VINKA, ten years on. Main scientific results

    International Nuclear Information System (INIS)

    1979-01-01

    The VINKA facility in the TRITON swimming-pool reactor at Fontenay-aux-Roses allows the irradiation of solids at low temperatures in order to study crystalline defects. After ten years of operation the main scientific results obtained in the fields of creep and growth (chapter I), point defects (chapter II), amorphisation (chapter III) and dechanneling of particles (chapter IV) are summarised [fr

  16. Results on Fermilab main injector dipole measurements

    International Nuclear Information System (INIS)

    Brown, B.C.; Baiod, R.; DiMarco, J.; Glass, H.D.; Harding, D.J.; Martin, P.S.; Mishra, S.; Mokhtarani, A.; Orris, D.F.; russell, O.A.; Tompkins, J.C.; Walbridge, D.G.C.

    1995-06-01

    Measurements of the Productions run of Fermilab Main Injector Dipole magnets is underway. Redundant strength measurements provide a set of data which one can fit to mechanical and magnetic properties of the assembly. Plots of the field contribution from the steel supplement the usual plots of transfer function (B/I) vs. I in providing insight into the measured results

  17. D.E.R. 92 - Main facts

    International Nuclear Information System (INIS)

    1992-01-01

    This report presents the main facts of the studies carried out by the Direction des Etudes et Recherches (DER) of Electricite de France: new applications of electricity, classical and nuclear thermal power plants, electrical equipment, environment protection, network analysis, information and informatic equipment

  18. Condition monitoring of main coolant pumps, Dhruva

    International Nuclear Information System (INIS)

    Prasad, V.; Satheesh, C.; Acharya, V.N.; Tikku, A.C.; Mishra, S.K.

    2002-01-01

    Full text: Dhruva is a 100 MW research reactor with natural uranium fuel, heavy water as moderator and primary coolant. Three Centrifugal pumps circulate the primary coolant across the core and the heat exchangers. Each pump is coupled to a flywheel (FW) assembly in order to meet operational safety requirements. All the 3 main coolant pump (MCP) sets are required to operate during operation of the reactor. The pump-sets are in operation since the year 1984 and have logged more than 1,00,000 hrs. Frequent breakdowns of its FW bearings were experienced during initial years of operation. Condition monitoring of these pumps, largely on vibration based parameters, was initiated on regular basis. Break-downs of main coolant pumps reduced considerably due to the fair accurate predictions of incipient break-downs and timely maintenance efforts. An effort is made in this paper to share the experience

  19. Alarm system for ABWR main control panels

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yuji; Saito, Koji [Toshiba Corp., Yokohoma (Japan)

    1997-09-01

    TOSHIBA has developed integrated digital control and instrumentation system for ABWR, which is the third-generation man machine interface system for main control room that we call A-PODIA (Advanced PODIA). A-Podia has been introduced the first actual ABWR plant in Japan. in A-PODIA, TOSHIBA has realized improvement of alarm system that all operator crews in the control room can recognize plant anomalies easily. The alarm system can recognize essential alarms for plant safety easily and understand annunciators with each integrated annunciators and their prioritized color easily by classifying alarms into plant-level essential annunciators, system-level integrated annunciators and equipment level individual annunciators with hierarchical structure. This paper describes conventional alarm system and the design philosophy, alarm system design and operation of ``Alarm System for ABWR Main Control Panels``. (author). 5 refs, 8 figs, 1 tab.

  20. Organization structure. Main activities of the Division

    International Nuclear Information System (INIS)

    2008-01-01

    In this chapter the organization structure as well as main activities of the Division for radiation safety, NPP decommissioning and radioactive waste management are presented. This Division of the VUJE, a.s. consists of the following sections and departments: Section for economic and technical services; Section for radiation protection of employees; Department for management of emergency situations and risk assessment; Department for implementation of nuclear power facilities decommissioning and RAW management; Department for personnel and environmental dosimetry; Department for preparation of NPP decommissioning; Department for RAW treatment technologies; Department for chemical regimes and physico-chemical analyses; Department for management of nuclear power facilities decommissioning and RAW management. Main activities of this Division are presented.

  1. Challenges of the ILC Main Linac

    International Nuclear Information System (INIS)

    Ross, Marc

    2007-01-01

    With the completion of the ILC Reference Design Report (RDR), we begin the next phase of the project - development of the Engineering Design. Our strategy and priorities come from the identification, contained in the RDR, of scientific and engineering challenges of the ILC. First among these is the cost of the main linac which, including the associated earthworks and cooling/power systems, amounts to 60% of the ILC total cost. Next is the challenge to reach the highest practical gradient since this R and D has the largest cost leverage of any of the ongoing programs. Finally, we have to understand the beam dynamics and beam tuning processes in the main linac, as we will not have the opportunity to do full (or even large) scale tests of these before the linac is constructed.

  2. Chromaticity compensation scheme for the Main Injector

    International Nuclear Information System (INIS)

    Bogacz, S.A.

    1993-05-01

    The current Main Injector lattice is studied in the context of full chromaticity compensation in the presence of the eddy current, saturation and the end-pack sextupole fields generated by the dipole magnets. Two families of correcting sextupole magnets are placed to compensate these fields and to adjust the chromaticity (in both planes) to some desired value. Variation of the dipole induced sextupole fields with the B-field (changing along a ramp) are modeled according to recent experimental measurements of the Main Injector dipole magnet Analysis of the required sextupole strengths is carried out along two realistic momentum ramps. The results of our calculation give quantitative insight into the requisite performance of the sextupole magnets

  3. Installation Strategy for the LHC Main Dipoles

    CERN Multimedia

    Fartoukh, Stephane David

    2004-01-01

    All positions in the LHC machine are not equivalent in terms of beam requirements on the geometry and the field quality of the main dipoles. In the presence of slightly or strongly out-of tolerance magnets, a well-defined installation strategy will therefore contribute to preserve or even optimize the performance of the machine. Based on the present status of the production, we have anticipated a list of potential issues (geometry, transfer function, field direction and random b3) which, combined by order of priority, have been taken into account to define a simple but efficient installation algorithm for the LHC main dipoles. Its output is a prescription for installing the available dipoles in sequence while reducing to an absolute minimum the number of holes required by geometry or FQ issues.

  4. The LHC Main Quadrupoles during Series Fabrication

    CERN Document Server

    Tortschanoff, Theodor; Durante, M; Hagen, P; Klein, U; Krischel, D; Payn, A; Rossi, L; Schellong, B; Schmidt, P; Simon, F; Schirm, K-M; Todesco, E

    2006-01-01

    By the end of August 2005 about 320 of the 400 main LHC quadrupole magnets have been fabricated and about 220 of them assembled into their cold masses, together with corrector magnets. About 130 of them have been cold tested in their cryostats and most of the quadrupoles exceeded their nominal excitation, i.e. 12,000 A, after no more than two training quenches. During this series fabrication, the quality of the magnets and cold masses was thoroughly monitored by means of warm magnetic field measurements, of strict geometrical checking, and of various electrical verifications. A number of modifications were introduced in order to improve the magnet fabrication, mainly correction of the coil geometry for achieving the specified field quality and measures for avoiding coil insulation problems. Further changes concern the electrical connectivity and insulation of instrumentation, and of the corrector magnets inside the cold masses. The contact resistances for the bus-bar connections to the quench protection diode...

  5. The double main sequence of Omega Centauri

    Science.gov (United States)

    Bedin, L. R.; Piotto, G.; Anderson, J.; King, I. R.; Cassisi, S.; Momany, Y.

    Recent, high precision photometry of Omega Centauri, the biggest Galactic globular cluster, has been obtained with Hubble Space Telescope (HST). The color magnitude diagram reveals an unexpected bifurcation of colors in the main sequence (MS). The newly found double MS, the multiple turnoffs and subgiant branches, and other sequences discovered in the past along the red giant branch of this cluster add up to a fascinating but frustrating puzzle. Among the possible explanations for the blue main sequence an anomalous overabundance of helium is suggested. The hypothesis will be tested with a set of FLAMES@VLT data we have recently obtained (ESO DDT program), and with forthcoming ACS@HST images. Based on observations with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555.

  6. Alarm system for ABWR main control panels

    International Nuclear Information System (INIS)

    Kobayashi, Yuji; Saito, Koji

    1997-01-01

    TOSHIBA has developed integrated digital control and instrumentation system for ABWR, which is the third-generation man machine interface system for main control room that we call A-PODIA (Advanced PODIA). A-Podia has been introduced the first actual ABWR plant in Japan. in A-PODIA, TOSHIBA has realized improvement of alarm system that all operator crews in the control room can recognize plant anomalies easily. The alarm system can recognize essential alarms for plant safety easily and understand annunciators with each integrated annunciators and their prioritized color easily by classifying alarms into plant-level essential annunciators, system-level integrated annunciators and equipment level individual annunciators with hierarchical structure. This paper describes conventional alarm system and the design philosophy, alarm system design and operation of ''Alarm System for ABWR Main Control Panels''. (author). 5 refs, 8 figs, 1 tab

  7. INNOVATION DIFFUSION THEORY MAIN DEVELOPMENT STAGES

    Directory of Open Access Journals (Sweden)

    S. V. Lisafiev

    2011-01-01

    Full Text Available Abstract: Main innovation diffusion development theory stages are: Rogers model of moving new products to the market including characteristics of its segments; mathematic substantiation of this model by Bass; Moor model taking into account gaps between adjacent market segments; Goldenberg model making it possible to predict sales drops at new product life cycle initial stages. It is reasonable to use this theory while moving innovative products to the market.

  8. Space shuttle main engine vibration data base

    Science.gov (United States)

    Lewallen, Pat

    1986-01-01

    The Space Shuttle Main Engine Vibration Data Base is described. Included is a detailed description of the data base components, the data acquisition process, the more sophisticated software routines, and the future data acquisition methods. Several figures and plots are provided to illustrate the various output formats accessible to the user. The numerous vibration data recall and analysis capabilities available through automated data base techniques are revealed.

  9. The Main Properties of q-Functions

    OpenAIRE

    Nina O. Virchenko; Olena V. Ovcharenko

    2017-01-01

    Background.  The new generalization of the function of complex variable (q-function) is considered, its main properties are investigated. Such distributions have a special place among the special functions due to their widespread use in many areas of applied mathematics. Objective. The aim of the paper is to study the new generalization of the function of complex variable for application in applied sciences. Methods. To obtain scientific results the general methods of the mathematical a...

  10. Radiation shielding of the main injector

    International Nuclear Information System (INIS)

    Bhat, C.M.; Martin, P.S.

    1995-05-01

    The radiation shielding in the Fermilab Main Injector (FMI) complex has been carried out by adopting a number of prescribed stringent guidelines established by a previous safety analysis. Determination of the required amount of radiation shielding at various locations of the FMI has been done using Monte Carlo computations. A three dimensional ray tracing code as well as a code based upon empirical observations have been employed in certain cases

  11. Post-main-sequence planetary system evolution

    Science.gov (United States)

    Veras, Dimitri

    2016-01-01

    The fates of planetary systems provide unassailable insights into their formation and represent rich cross-disciplinary dynamical laboratories. Mounting observations of post-main-sequence planetary systems necessitate a complementary level of theoretical scrutiny. Here, I review the diverse dynamical processes which affect planets, asteroids, comets and pebbles as their parent stars evolve into giant branch, white dwarf and neutron stars. This reference provides a foundation for the interpretation and modelling of currently known systems and upcoming discoveries. PMID:26998326

  12. The BTeV main spectrometer

    International Nuclear Information System (INIS)

    Sheldon, P.D.

    2001-01-01

    BTeV is a second generation B-factory experiment that will use a double-arm, forward spectrometer in the C0 experimental hall at the Fermilab Tevatron. I will describe the motivation and design of the 'main spectrometer', consisting of a ring-imaging Cherenkov system for charged particle identification, an electromagnetic calorimeter of lead-tungstate crystals, a proportional tube muon system with magnetized filtering steel, and a straw-tube and silicon strip charged particle tracking system

  13. Main-sequence photometry in NGC 2808

    International Nuclear Information System (INIS)

    Buonanno, R.; Corsi, C.E.; Fusi Pecci, F.; Harris, W.E.

    1984-01-01

    We have obtained a color-magnitude diagram for the southern globular cluster NGC 2808, to V/sub lim/approx. =21 (about 2 mag below the main-sequence turnoff). The internal photographic errors are sigma/sub V/approx. =0.02, sigma/sub B/-Vapprox. =0.03, small enough to permit a precise definition of the turnoff region and an estimate of the ''cosmic scatter'' along the main sequence. Fitting of the CMD to VandenBerg's [Astrophys. J. Suppl. 51, 29 (1983)] isochrones shows that an excellent match to the observations is achieved for model parameters of Yapprox. =0.2, Zapprox. =0.003 ([Fe/H]approx. =-0.8), and an age of (16 +- 2) billion years. All these characteristics are within the expected range from other observational constraints; no new clues from the main-sequence data alone have arisen to help explain the presence of the anomalous blue horizontal-branch stars

  14. Isolated systems with wind power. Main report

    Energy Technology Data Exchange (ETDEWEB)

    Lundsager, P.; Bindner, H.; Clausen, N.E.; Frandsen, S.; Hansen, L.H.; Hansen, J.C.

    2001-06-01

    The overall objective of this research project is to study the development of methods and guidelines rather than 'universal solutions' for the use of wind energy in isolated communities. The main specific objective of the project is to develop and present a more unified and generally applicable approach for assessing the technical and economical feasibility of isolated power supply systems with wind energy. As a part of the project the following tasks were carried out: Review of literature, field measurements in Egypt, development of an inventory of small isolated systems, overview of end-user demands, analysis of findings and development of proposed guidelines. The project is reported in one main report and four topical reports, all of them issued as Risoe reports. This is the Main Report Risoe-R-1256, summing up the activities and findings of the project and outlining an Implementation Strategy for Isolated Systems with Wind Power, applicable for international organisations such as donor agencies and development banks. (au)

  15. Rates of the main thermonuclear reactions

    International Nuclear Information System (INIS)

    Abramovich, S.N.; Guzhovskii, B.Ya.; Dunaeva, S.A.; Fomushkin, E.F.

    1992-01-01

    The data on the cross sections of main thermonuclear reactions have been estimated with an account of the latest experimental results in a form of S-factor spline presentation. Based on this estimation, the reates of these reactions in 0.0001-1 MeV temperature range in the supposition of Maxwell distribution of relative velocities have been computed. The Maxwell-Boltzmann averaged -factors were calculated according to the table values of the reaction rates. Then the -factors were approximated with the 3 order spline-function. The necessity of the account of electron shielding and intramolecular movement at low temperatures is discussed (orig.)

  16. Musculoskeletal disorders in main battle tank personnel

    DEFF Research Database (Denmark)

    Nissen, Lars Ravnborg; Guldager, Bernadette; Gyntelberg, Finn

    2009-01-01

    PURPOSE: To compare the prevalence of musculoskeletal disorders of personnel in the main battle tank (MBT) units in the Danish army with those of personnel in other types of army units, and to investigate associations between job function in the tank, military rank, and musculoskeletal problems......, and ankle. RESULTS AND CONCLUSIONS: There were only 4 women in the MBT group; as a consequence, female personnel were excluded from the study. The participation rate was 58.0% (n = 184) in the MBT group and 56.3% (n = 333) in the reference group. The pattern of musculoskeletal disorders among personnel...

  17. Main problems of modern radiation hygiene

    International Nuclear Information System (INIS)

    Il'in, L.A.; Buldakov, L.A.; Knizhnikov, V.A.

    1982-01-01

    The results of investigations carried out in 1980-81 in the field of radiation hygiene as well as plans for 1981-85 are considered. Three main groups of problems which the radiation hygiene is facing at the present time are discussed. The determination of levels and study of regularities of ionizing radiation dose formation in the population and personnel working with ionizing radiation sources in one of the promissing directions of the investigations. Delayed irradiation aftereffects andcontaminant action ofirradiation and chemical substances are no less important. The third important problem lies in the development of protective measures and arrangements on improving state sanitary inspection in the field of radiation hygiene

  18. Some peat deposits in Penobscot County, Maine

    Science.gov (United States)

    Cameron, Cornelia Clermont; Anderson, Walter A.

    1979-01-01

    Twenty of the peat deposits in Penobscot County, Maine contain an estimated 29,282,000 short tons air-dried peat. The peat is chiefly sphagnum moss and reed-sedge of high quality according to ASTM standards for agricultural and horticultural use. Analyses show that this same volume has high fuel value, low sulfur and high hydrogen contents compared with lignite and sub-bituminous coal, which may indicate that it also has potential for fuel use. On the basis of the metallic trace element content, one area within the region containing the 20 deposits has been delineated for further bedrock studies.

  19. Main-chain supramolecular block copolymers.

    Science.gov (United States)

    Yang, Si Kyung; Ambade, Ashootosh V; Weck, Marcus

    2011-01-01

    Block copolymers are key building blocks for a variety of applications ranging from electronic devices to drug delivery. The material properties of block copolymers can be tuned and potentially improved by introducing noncovalent interactions in place of covalent linkages between polymeric blocks resulting in the formation of supramolecular block copolymers. Such materials combine the microphase separation behavior inherent to block copolymers with the responsiveness of supramolecular materials thereby affording dynamic and reversible materials. This tutorial review covers recent advances in main-chain supramolecular block copolymers and describes the design principles, synthetic approaches, advantages, and potential applications.

  20. Additively Manufactured Main Fuel Valve Housing

    Science.gov (United States)

    Eddleman, David; Richard, Jim

    2015-01-01

    Selective Laser Melting (SLM) was utilized to fabricate a liquid hydrogen valve housing typical of those found in rocket engines and main propulsion systems. The SLM process allowed for a valve geometry that would be difficult, if not impossible to fabricate by traditional means. Several valve bodies were built by different SLM suppliers and assembled with valve internals. The assemblies were then tested with liquid nitrogen and operated as desired. One unit was also burst tested and sectioned for materials analysis. The design, test results, and planned testing are presented herein.

  1. Water Hammer in Pumped Sewer Mains

    DEFF Research Database (Denmark)

    Larsen, Torben

    of transients in pumped pipeline systems. This present publication can be understood as the second and revised edition of the pamphlet ”Transients in pumped sewer mains” (2006) which was published as a technical report by The EVA committee under The Danish Water Pollution Committee (The Danish Society......This publication is intended for students and engineers seeking an introduction to the problem of water transients in pumped sewer and water mains. This is a subject of increasing interest because of the development of larger and more integrated systems. Consideration of transients is essential...

  2. Space Shuttle Main Engine Public Test Firing

    Science.gov (United States)

    2000-01-01

    A new NASA Space Shuttle Main Engine (SSME) roars to the approval of more than 2,000 people who came to John C. Stennis Space Center in Hancock County, Miss., on July 25 for a flight-certification test of the SSME Block II configuration. The engine, a new and significantly upgraded shuttle engine, was delivered to NASA's Kennedy Space Center in Florida for use on future shuttle missions. Spectators were able to experience the 'shake, rattle and roar' of the engine, which ran for 520 seconds - the length of time it takes a shuttle to reach orbit.

  3. Main challenges in demulsifier research and application

    Science.gov (United States)

    Zhang, Fusheng; Liu, Guoliang; Ma, Junhan; Ouyang, Jian; Yi, Xiaoling; Su, Huimin

    2017-01-01

    Main challenges in demulsifier research, such as demulsification of ASP flooding produced liquid, demulsification of heavy oil produced liquid, low temperature demulsification and fast demulsification, are summarized. Some importance technology routes to solve the challenges are proposed according to demulsification mechanisms and emulsion characteristics. The proposed routes include increasing aromaticity, molecular weight and branch degree of demulsifiers, and introducing double-function groups to demulsifiers for W/O and O/W emulsions, or groups with alkyl matching with alkyl carbon number of the crude oil into demulsifier molecule. The demulsification mechanisms of the above-mentioned research routes are described in detail.

  4. Isolated systems with wind power. Main report

    DEFF Research Database (Denmark)

    Lundsager, P.; Bindner, Henrik W.; Clausen, Niels-Erik

    2001-01-01

    The overall objective of this research project is to study the development of methods and guidelines rather than "universal solutions" for the use of wind energy in isolated communities. The main specific objective of the project is to develop and present amore unified and generally applicable...... approach for assessing the technical and economical feasibility of isolated power supply systems with wind energy. As a part of the project the following tasks were carried out: Review of literature, fieldmeasurements in Egypt, development of an inventory of small isolated systems, overview of end...... for Isolated Systems with Wind Power, applicable for international organisations such as donoragencies and development banks....

  5. Forensic entomology and main challenges in Brazil.

    Science.gov (United States)

    Gomes, Leonardo; Von Zuben, Cláudio J

    2006-01-01

    Apart from an early case report from China (13th century), the first observations on insects and other arthropods as forensic indicators were documented in Germany and France during mass exhumations in the 1880s by Reinhard, who is considered a co-founder of the discipline. After the French publication of Mégnin's popular book on the applied aspects of forensic entomology, the concept quickly spread to Canada and United States. At that time, researchers recognized that the lack of systematic observations of insects of forensic importance jeopardized their use as indicators of postmortem interval. General advances in insect taxonomy and ecology helped to fill this gap over the following decades. After World Wars, few forensic entomology cases were reported in the scientific literature. From 1960s to the 1980s, Leclercq and Nuorteva were primarily responsible for maintaining the method in Central Europe, reporting isolated cases. Since then, basic research in the USA, Russia and Canada opened the way to the routine use of Entomology in forensic investigations. Identifications of insects associated with human cadavers are relatively few in the literature of the Neotropical region and have received little attention in Brazil. This article brings an overview of historic developments in this field, the recent studies and the main problems and challenges in South America and mainly in Brazil.

  6. Main Issues in Big Data Security

    Directory of Open Access Journals (Sweden)

    Julio Moreno

    2016-09-01

    Full Text Available Data is currently one of the most important assets for companies in every field. The continuous growth in the importance and volume of data has created a new problem: it cannot be handled by traditional analysis techniques. This problem was, therefore, solved through the creation of a new paradigm: Big Data. However, Big Data originated new issues related not only to the volume or the variety of the data, but also to data security and privacy. In order to obtain a full perspective of the problem, we decided to carry out an investigation with the objective of highlighting the main issues regarding Big Data security, and also the solutions proposed by the scientific community to solve them. In this paper, we explain the results obtained after applying a systematic mapping study to security in the Big Data ecosystem. It is almost impossible to carry out detailed research into the entire topic of security, and the outcome of this research is, therefore, a big picture of the main problems related to security in a Big Data system, along with the principal solutions to them proposed by the research community.

  7. A random walk down Main Street

    Directory of Open Access Journals (Sweden)

    David Matthew Levinson

    2016-08-01

    Full Text Available US suburbs have often been characterized by their relatively low walk accessibility compared to more urban environments, and US urban environments have been char- acterized by low walk accessibility compared to cities in other countries. Lower overall density in the suburbs implies that activities, if spread out, would have a greater distance between them. But why should activities be spread out instead of developed contiguously? This brief research note builds a positive model for the emergence of contiguous development along “Main Street” to illustrate the trade-offs that result in the built environment we observe. It then suggests some policy interventions to place a “thumb on the scale” to choose which parcels will develop in which sequence to achieve socially preferred outcomes.

  8. Mortise terrorism on the main pipelines

    Science.gov (United States)

    Komarov, V. A.; Nigrey, N. N.; Bronnikov, D. A.; Nigrey, A. A.

    2018-01-01

    The research aim of the work is to analyze the effectiveness of the methods of physical protection of main pipelines proposed in the article from the "mortise terrorism" A mathematical model has been developed that made it possible to predict the dynamics of "mortise terrorism" in the short term. An analysis of the effectiveness of physical protection methods proposed in the article to prevent unauthorized impacts on the objects under investigation is given. A variant of a video analytics system has been developed that allows detecting violators with recognition of the types of work they perform at a distance of 150 meters in conditions of complex natural backgrounds and precipitation. Probability of detection is 0.959.

  9. Siberian snakes for the Fermilab Main Injector

    International Nuclear Information System (INIS)

    Anferov, V.A.; Baiod, R.; Courant, E.D.

    1993-01-01

    Appropriate Siberian snakes were designed to maintain the proton beam polarization during acceleration in the Fermilab Main Injector from 8 to 150 GeV. Various snake designs were investigated to find one fitting into the 14 m straight section spaces with the required spin rotation axis and the minimum orbit excursion. The authors studied both cold and warm discrete magnet snakes as well as warm snakes with helical magnets. For the warm discrete magnet snake, obtaining small orbit excursions required a nearly longitudinal snake axis, while axes near ±45 degrees are needed when using two snakes in a ring. The authors found acceptable snakes either by using superconducting magnets or by using warm magnets with a helical dipole field

  10. CBA main magnet power supply ripple reduction

    International Nuclear Information System (INIS)

    Bagley, G.; Edwards, R.J.

    1983-01-01

    The preliminary results of a development program to minimize beam perturbation resulting from ripple current generated by the CBA Main Magnet Power Supply are presented. The assessment of the magnitude and causes of the ripple generated led to a modification of the SCR Gate Driver and the addition of a bandpass amplifier correction loop which gave significant improvement. A description of the changes made and the results obtained are included. A second design approach was developed in which the timing of the SCR gate pulses is directly determined by a VCO. The results reported with this VCO Loop indicate superior performance particularly at frequencies below 60 Hz. A shunt transistor regulator design is proposed to minimize higher SCR switching frequency harmonics

  11. BANKING ETHICS: MAIN CONCEPTIONS AND PROBLEMS

    Directory of Open Access Journals (Sweden)

    VALENTINA FETINIUC

    2014-10-01

    Full Text Available Banking ethics is a specialized set of ethical standards and rules that should be followed in the activities of financial institutions and employees of the banking sector. But despite the simplicity of the definition, in the modern world, this concept becomes complex and ambiguous. The importance of studying this subject is defined by the fact that the ethical behavior of the bank and bank employees promotes banking. At present there are several conceptions of banking ethics: general ethics, regulated ethics and ethical bank. The most common practice is to regulate internal and external relations of banks and bank workers with ethical codes. At the same time, studies show the existence of problems in the banking standards of ethics, which negatively affects the financial institution. This article is intended to reflect main tendencies and problems of banking ethics at international level and experience of Republic of Moldova in this field.

  12. Seismic risks at Elsie Lake Main Dam

    International Nuclear Information System (INIS)

    McCammon, N.R.; Momenzadeh, M.; Hawson, H.H.; Nielsen, N.M.

    1991-01-01

    The Elsie Lake dams are located on Vancouver Island in an area of high seismic risk. A safety review in 1986 indicated potential deficiencies in the earthfill main dam with respect to modern earthquake design standards. A detailed field investigation program comprising drilling and penetration tests was carried out and the results used in an assessment of seismic stability. A 0.8 m thick less dense layer in the granular shell of the dam, possibly caused by wet construction conditions, would likely liquefy in a major earthquake but sufficient residual strength would likely remain to prevent catastrophic failure. The dam shell might undergo some distortion, and an assessment was initiated to determine the requirements for reservoir drawdown following an extreme earthquake to ensure the timely lowering of the reservoir for inspection and repair. It was suggested that an adequate evacuation capability would be 25% and 50% drawdown in not more than 30 and 50 days, respectively. 9 refs., 11 figs., 1 tab

  13. Natural syntax : English interrogative main clauses

    Directory of Open Access Journals (Sweden)

    Janez Oresnik

    2007-12-01

    Full Text Available Natural Syntax is a developing deductive theory, a branch of Naturalness Theory. The naturalnessjudgements are couched in naturalness scales, whichfollow from the basic parameters (or «axioms» listed at the beginning of the paper. The predictions of the theory are calculated in deductions, whose chief components are apair of naturalness scales and the rules governing the alignment of corresponding naturalness values. Parallel and chiastic alignments are distinguished, in complementary distribution. Chiastic alignment is mandatory in deductions limited to unnatural environments. The paper deals with English interrogative main clauses. Within these, only the interrogatives containing wh-words exclusively insitu constitute an extremely unnatural environment and require chiastic alignment. Otherwiseparallel alignment is used. Earlier publications on Natural Syntax: Kavcic 2005a,b, Oresnik 1999, 2000a,b, 200la-f   2002, 2003a-c, 2002/03, 2004. This list cites only works written in English.

  14. PS main supply: motor-generator set.

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    In picture 04 the motor is on the right in the background and the main view is of the generator. The peak power in each PS cycle drawn from the generator, up to 96 MW, is taken from the rotational kinetic energy of the rotor (a heavy-weight of 80 tons), which makes the rotational speed drop by only a few percent. The motor replenishes the average power of 2 to 4 MW. Photo 05: The motor-generator set is serviced every year and, in particular, bearings and slip-rings are carefully checked. To the left is the motor with its slip-rings visible. It has been detached from the axle and moved to the side, so that the rotor can be removed from the huge generator, looming at the right.

  15. VAT EVASION INLEBANON: CASES AND MAIN CAUSES

    Directory of Open Access Journals (Sweden)

    Rana Ismail

    2012-07-01

    Full Text Available The Value Added Tax (VAT is a very important source oftreasuryrevenuesinLebanon. It was initially introduced inLebanon in order to reduce the budgetdeficit and help contain the debt. However, VAT evasion growth inLebanon isleading to significant VAT revenue losses because of its size and frequency.In this paper, we will highlight the contribution of VAT to the treasury revenue. Inaddition, our research has led to figure out the most significant VAT evasion casesand the way tax payers evade paying their required VAT or try to have an illegalrefund. From these tax evasion cases, we will pinpoint the main causes of suchevasions and propose solutions to limit as much as possible VAT evasion inLebanon.

  16. Main clinical epidemiological features of lung cancer

    International Nuclear Information System (INIS)

    Costa Montane, Daniel Marino; Prado Lage, Yulien; Lozano Salazar; Jorge Luis

    2011-01-01

    A descriptive and cross-sectional study of 95 patients with lung cancer, discharged from Neumology Service at 'Dr Juan Bruno Zayas Alfonso' General Hospital in Santiago de Cuba, was carried out from January, 2008 to December, 2008 in order to identify the main clinical epidemiological features of the aforementioned disease. A malignancy predominance among men aged between 56 and 65 years old, belonging to urban areas and being heavy smoker (out of 30 cigarettes per day over 30 years ), was found. Those affected without a confirmed histological type and IV clinical stage epidermoid carcinoma were predominant. Most of them had the opportunity to be treated. Increasing and intensifying health promotion and disease prevention campaigns were recommended so as to achieve the population to avoid or quit the smoking habit. (author)

  17. Main heat transfer components for SNR-300

    International Nuclear Information System (INIS)

    De Haas Van Dorsser, A.H.

    1976-01-01

    Early in the joint German-Belgium-Dutch fast breeder programme it was decided that all main components should be tested, if possible at full scale, before fabrication of the actual SNR-300 components. Descriptions are given of the results of testing, and subsequent modifications, of the pumps, intermediate heat exchangers, and steam generators. A full scale model of the primary pump, free surface vertical shaft centrifugal type, was constructed and tested in the 5000 cubic metres per hour pump test facility erected at Bensberg. A 70 MW model of an intermediate heat exchanger, straight tube type with floating head, was tested in the 50 MW steam generator test station at Hengelo. Also tested in the Hengelo facility was an almost full scale straight tube 50 MW steam generator and subsequently a 50 MW helical tube evaporator. The latter tests were of more than 3000 h operation and resulted in minor changes in design and manufacturing operation. (U.K.)

  18. Main Findings: Lessons to be Learnt

    International Nuclear Information System (INIS)

    2010-01-01

    This section summarizes the main lessons to be learnt from the workshop: 1 - Workshop Methodology: This method of work has proven to be successful. Participants appreciated the high level of interaction with the other colleagues, especially in view of the variety of expertise that was represented at the workshop. The method also affords the participants the opportunity to learn about the status of waste management in the host country, and to come into contact with the main actors. Conversely, the method also affords the host country programme added visibility at the international level. 2 - National Regulations and International Guidance and Bases for Criteria and Regulatory Judgement: There is reasonable consensus amongst national regulations on fundamental regulatory objectives, but much less agreement on the most appropriate criteria. Consensus is nationally and internationally hampered by the lack of common definition of concepts and terms. International guidance is interpreted in different ways in each country. International guidance is rather difficult to interpret, understand and apply. It is important that stakeholders understand the bases for regulatory judgements. 3 - Optimisation: The fundamental goals of optimisation need to be clarified. Optimisation of long-term vs. short-term safety remains problematic. The process of performing optimisation is more important than the numerical or scientific result. A transparent, stepwise and iterative process of decision making is essential for optimisation. The basic, broad rules for decision making and involvement of stakeholders need to be defined in advance. 4 - Technical Indicators for Safe Performance: The relative importance of different safety indicators varies with timescale. There is still much to be done before reaching consensus on the relative importance of different time frames. More discussion is needed on time cut-offs for regulatory compliance. More discussion on the meaning and applicability of

  19. Maine Environmental Vulnerability Index (EVI) Atlas, Maine - 2007, maps in portable document format (NODC Accession 0036827)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This four volume set of Environmental Vulnerability Index Maps depicts environmental resources along the coast of Maine most at risk from oil spilled into the marine...

  20. Main attributes influencing spent nuclear fuel management

    International Nuclear Information System (INIS)

    Andreescu, N.; Ohai, D.

    1997-01-01

    All activities regarding nuclear fuel, following its discharge from the NPP, constitute the spent fuel management and are grouped in two possible back end variants, namely reprocessing (including HLW vitrification and geological disposal) and direct disposal of spent fuel. In order to select the appropriate variant it is necessary to analyse the aggregate fulfillment of the imposed requirements, particularly of the derived attributes, defined as distinguishing characteristics of the factors used in the decision making process. The main identified attributes are the following: - environmental impact, - availability of suitable sites, - non-proliferation degree, -strategy of energy, - technological complexity and technical maturity, -possible further technical improvements, - size of nuclear programme, - total costs, - public acceptance, - peculiarity of CANDU fuel. The significance of the attributes in the Romanian case, taking into consideration the present situation, as a low scenario and a high scenario corresponding to an important development of the nuclear power, after the year 2010, is presented. According to their importance the ranking of attributes is proposed . Subsequently, the ranking could be used for adequate weighing of attributes in order to realize a multi-criteria analysis and a relevant comparison of back end variants. (authors)