WorldWideScience

Sample records for low-pressure multiwire proportional

  1. Time-zero fission-fragment detector based on low-pressure multiwire proportional chambers

    International Nuclear Information System (INIS)

    Assamagan, K.; Baker, K.; Bayatyan, G.; Carlini, R.; Danagoulian, S.; Eden, T.; Egiyan, K.; Ent, R.; Fenker, H.; Gan, L.; Gasparian, A.; Grigoryan, N.; Greenwood, Z.; Gueye, P.; Hashimoto, O.; Johnston, K.; Keppel, C.; Knyazyan, S.; Majewski, S.; Margaryan, A.; Margaryan, Yu.; Marikyan, G.; Martoff, J.; Mkrtchyan, H.; Parlakyan, L.; Sato, Y.; Sawafta, R.; Simicevic, N.; Tadevosyan, V.; Takahashi, T.; Tang, L.; Vartanyan, G.; Vulcan, W.; Wells, S.; Wood, S.

    1999-01-01

    A time-zero fission fragment (FF) detector, based on the technique of low-pressure multiwire proportional chambers (LPMWPC), has been designed and constructed for the heavy hypernuclear lifetime experiment (E95-002) at Thomas Jefferson National Accelerator Facility. Its characteristics and the method of time-zero reconstruction were investigated using fission fragments from a 252 Cf spontaneous fission source. The influence of the ionization energy loss was also studied. It is shown that Heptane, Hexane, and Isobutane gases at a pressure of 1-2 Torr are all suitable for such a FF detector. As desired by experiment, a timing resolution of about 200 ps (FWHM) for a chamber size of 21x21 cm 2 was achieved

  2. Time-zero fission-fragment detector based on low-pressure multiwire proportional chambers

    CERN Document Server

    Assamagan, Ketevi A; Bayatyan, G L; Carlini, R; Danagulyan, S; Eden, T; Egiyan, K; Ent, R; Fenker, H; Gan, L; Gasparian, A; Grigoryan, N K; Greenwood, Z; Gueye, P; Hashimoto, O; Johnston, K; Keppel, C; Knyazyan, S; Majewski, S; Margaryan, A; Margaryan, Yu L; Marikian, G G; Martoff, J; Mkrtchyan, H G; Parlakyan, L; Sato, Y; Sawafta, R; Simicevic, N; Tadevosyan, V; Takahashi, T; Tang, L; Vartanian, G S; Vulcan, W; Wells, S; Wood, S

    1999-01-01

    A time-zero fission fragment (FF) detector, based on the technique of low-pressure multiwire proportional chambers (LPMWPC), has been designed and constructed for the heavy hypernuclear lifetime experiment (E95-002) at Thomas Jefferson National Accelerator Facility. Its characteristics and the method of time-zero reconstruction were investigated using fission fragments from a sup 2 sup 5 sup 2 Cf spontaneous fission source. The influence of the ionization energy loss was also studied. It is shown that Heptane, Hexane, and Isobutane gases at a pressure of 1-2 Torr are all suitable for such a FF detector. As desired by experiment, a timing resolution of about 200 ps (FWHM) for a chamber size of 21x21 cm sup 2 was achieved.

  3. Low-pressure, multistep, multiwire proportional counter for the time-of-flight isochronous spectrometer

    International Nuclear Information System (INIS)

    Vieira, D.J.

    1985-01-01

    A low-pressure, multistep, multiwire proportional counter (MSMWPC) has been developed for the characterization and testing of the time-of-flight isochronous (TOFI) spectrometer and its associated secondary-beam transport line. This type of counter was selected because of its high sensitivity, large dynamic range, and good position (0.2 mm FWHM) and timing (180 ps FWHM) resolution. Furthermore, because the counter operates at low gas pressures (1-10 torr) and high electric-field strengths, which enable short collection times, it can be used as a transmission counter with thin gas-isolation windows and it can operate at high counting rates. Here the authors discuss the basic operating principle of the MSMWPC, describe the technical details of the detector and signal processing, and report on the performance they have measured for alpha particles and fission fragments

  4. CATS, a low pressure multiwire proportional chamber for secondary beam tracking at GANIL

    CERN Document Server

    Ottini-Hustache, S; Auger, F; Musumarra, A; Alamanos, N; Cahan, B; Gillibert, A; Lagoyannis, A; Maillard, O; Pollacco, E; Sida, J L; Riallot, M

    1999-01-01

    A beam detector system, CATS (Chambre A Trajectoires de Saclay), was designed to provide event-by-event particle tracking in experiments with radioactive beams at GANIL. It consists of two low pressure multiwire proportional chambers with one plane of anode wires placed between two cathode planes (active area: 70x70 mm sup 2), respectively segmented into 28 vertical or horizontal strips (2.54 mm wide). The anode wires deliver a time signal allowing a time of flight measurement with an accuracy between 440 ps and 1.2 ns, depending on the energy loss of incident particles in the detector. The cathode strips are individually read out and the position of incoming particles is reconstructed using a charge centroid finding algorithm. A spatial resolution of 400 mu m (700 mu m) was achieved during in beam experiment, with a counting rate of 1.5x10 sup 5 (10 sup 6) particles per second. (author)

  5. Multiwire proportional chamber and multistage avalanche chamber with low concentration photoionization gas

    International Nuclear Information System (INIS)

    Zhao Pingde; Xu Zhiqing; Tang Xiaowei

    1986-01-01

    The characteristics of multiwire proportional chamber and multistage avalanche chamber filled with argon and photoionization gas (C 2 H 5 ) 3 N were measured. The spatial resolution curves and output pulse height spectra were measured as well. Low concentration (C 2 H 5 ) 3 N can play an effective part in quenching. At very low concentration, the phenomena of avalanche transverse expansion was observed obviously

  6. A multiwire proportional chamber for precision studies of neutron β decay angular correlations

    International Nuclear Information System (INIS)

    Ito, T.M.; Carr, R.; Filippone, B.W.; Martin, J.W.; Plaster, B.; Rybka, G.; Yuan, J.

    2007-01-01

    A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron β decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas and an entrance window made of thin Mylar sheet reinforced with Kevlar fibers. In the initial off-line performance tests, the gas gain of neopentane and the position resolution were studied

  7. Investigation of a multiwire proportional chamber

    International Nuclear Information System (INIS)

    Konijn, J.

    1976-01-01

    The article discusses some aspects of a prototype multiwire proportional chamber for electron detection located at IKO in Amsterdam, i.e. voltage, counting rates, noise and gas mixture (argon, ethylene bromide). The efficiency and performance of the chamber have been investigated and an error analysis is given

  8. Medical applications of multi-wire proportional chambers

    International Nuclear Information System (INIS)

    Reading, D.H.

    1976-05-01

    The adaption of Multi-Wire Proportional Chambers (MWPC) for medical applications has necessitated bi-dimensional readout. This is achieved by analysing signals induced onto the cathode planes. At a useful X-ray energy of 40 to 45 keV, just above the K absorption edge in Xenon, the efficiency and resolution are both optimized. Poor resolution events due to K shell fluorescent capture and Auger emission, or L shell photo-electron emission, may be rejected by using energy discrimination - resulting in approximately halving the efficiency to 8% for a 1.6 cm thick atmospheric pressure chamber, but with sub millimeter inherent resolution. This is still far inferior to film resolution, but the MWPC is useful when numbers are required for computation or retrieval. Short descriptions of the MWPC applications to bone density measurements and tomography are given. Its use when pressurized as a gamma camera is discussed, and it is concluded that it may prove useful as a portable special purpose camera, or as one with a very large area thus compensating for low efficiency. Developments with liquid filled chambers are given and also the promising positron imaging hybrid MWPC. (author)

  9. Very large area multiwire spectroscopic proportional counters

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F.

    1981-01-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) succesfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm 2 with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results. (orig.)

  10. Very large area multiwire spectroscopic proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F. (Istituto di Astrofisica Spaziale, Frascati (Italy))

    1981-07-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) successfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm/sup 2/ with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results.

  11. Development of multiwire proportional chambers

    CERN Multimedia

    Charpak, G

    1969-01-01

    It has happened quite often in the history of science that theoreticians, confronted with some major difficulty, have successfully gone back thirty years to look at ideas that had then been thrown overboard. But it is rare that experimentalists go back thirty years to look again at equipment which had become out-dated. This is what Charpak and his colleagues did to emerge with the 'multiwire proportional chamber' which has several new features making it a very useful addition to the armoury of particle detectors. In the 1930s, ion-chambers, Geiger- Muller counters and proportional counters, were vital pieces of equipment in nuclear physics research. Other types of detectors have since largely replaced them but now the proportional counter, in new array, is making a comeback.

  12. Properties of a barium fluoride-TMAE-multiwire proportional chamber detector using a large single crystal

    International Nuclear Information System (INIS)

    Woody, C.L.; Petridou, C.I.; Smith, G.C.

    1985-01-01

    The properties of a detector consisting of a large barium fluoride crystal and a multiwire proportional chamber operating at low pressure with TMAE have been studied. Measurements of the time resolution, pulse width, energy resolution, photoelectron yield and the effective energy threshold were carried out in a test beam using minimum ionizing particles. Although the detector is sensitive to signals originating from an adsorbed layer of TMAE from the crystal surface, no indication of such a signal was observed. 7 refs., 6 figs

  13. Principles of operation of multiwire proportional and drift chambers

    International Nuclear Information System (INIS)

    Sauli, F.

    1987-01-01

    The first multiwire proportional chamber, in its modern conception, was constructed and operated in the years 1967-68. It was soon recognized that the main properties of a multiwire proportional chamber, i.e. very good time resolution, good position accuracy and self-triggered operation, are very attractive for the use of the new device in high-energy physics experiments. Today, most fast detectors contain a large number of proportional chambers, and their use has spread to many different fields of applied research, such as X-ray and heavy ion astronomy, nuclear medicine, and protein crystallography. In many respects, however, multiwire proportional chambers are still experimental devices, requiring continuous attention for good operation and sometimes reacting in unexpected ways to a change in the environmental conditions. Furthermore, in the fabrication and operation of a chamber people seem to use a mixture of competence, technical skill and magic rites, of the kind ''I do not know why I'm doing this but somebody told me to do so''. In these notes the authors illustrate the basic phenomena underlying the behaviour of a gas detector, with the hope that the reader will not only better understand the reasons for some irrational-seeming preferences (such as, for example, in the choice of the gas mixture), but will also be able better to design detectors for his specific experimental needs

  14. Multiwire proportional chamber development

    Science.gov (United States)

    Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.

    1973-01-01

    The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

  15. A powerful, low-cost histogramming memory for digital radiography with multi-wire proportional counters

    International Nuclear Information System (INIS)

    Bateman, J.E.; Locke, C.E.R.; Ferrari, C.A.

    1986-01-01

    A powerful, low-cost histogramming memory for digital radiograph with multi-wire proportional counter is described. The memory is based on a commercial video display device coupled to an Apple II microcomputer which, at a total cost of around 2500 pounds gives a system with 512 x 512 pixel resolution and a counting range of 4095 counts per pixel. The system can take data at rates of up to 5000 Hz while providing a live-time display. No hardware modifications are necessary, the comprehensive storage and display facilities being implemented in a combined package of BASIC and ASSEMBLER software. An ACCELERATOR coprocessor card is used to enhance the performance of the system. (author)

  16. Portable multiwire proportional chamber imaging system for high resolution 125I imaging

    International Nuclear Information System (INIS)

    Lazewatsky, J.L.; Lanza, R.C.; Murray, B.W.; Bolon, C.; Burns, R.E.; Szulc, M.

    1976-01-01

    A dedicated multiwire proportional chamber system designed to image 125 I labeled venous thrombi is described. The chamber is filled with a Kr-Co 2 gas mixture at one atmosphere pressure and utilizes an externally mounted delay line readout. A pair of crossed x-ray grids form a collimator which yields an optimum system efficiency of 3.1 x 10 -4 for a fixed spatial resolution of 0.74 cm. The chamber is further designed to be lightweight and portable for in-hospital use

  17. Amplification and discrimination of signals from proportional multiwire chambers

    International Nuclear Information System (INIS)

    Papadopoulos, L.; Bosio, C.; Cordelli, M.

    1976-03-01

    A circuit is described which detects signals from proportional multiwire chambers. The threshold is about 3μ A and the time jitter of the pulse obtained is better than 2.5 ns. The circuit has one negative input and two complementary outputs. The realized module includes 8 channels with common trigger level control and was built as NIM standard unit

  18. Imaging camera with multiwire proportional chamber

    International Nuclear Information System (INIS)

    Votruba, J.

    1980-01-01

    The camera for imaging radioisotope dislocations for use in nuclear medicine or for other applications, claimed in the patent, is provided by two multiwire lattices for the x-coordinate connected to a first coincidence circuit, and by two multiwire lattices for the y-coordinate connected to a second coincidence circuit. This arrangement eliminates the need of using a collimator and increases camera sensitivity while reducing production cost. (Ha)

  19. Improving the spatial resolution of the multiple multiwire proportional chamber gamma camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.

    1978-03-01

    Results are presented showing how the spatial resolution of the multiple multiwire proportional chamber (MMPC) gamma camera may be improved. Under the best conditions 1.6 mm bars can be resolved. (author)

  20. Positron imaging with multiwire proportional chamber-gamma converter hybrid detectors

    International Nuclear Information System (INIS)

    Chu, D.Y.H.

    1976-09-01

    A large area positron camera was developed using multiwire proportional chambers as detectors and electromagnetic delay lines for coordinate readout. Honeycomb structured gamma converters made of lead are coupled to the chambers for efficient gamma detection and good spatial resolution. Two opposing detectors, each having a sensitive area of 48 cm x 48 cm, are operated in coincidence for the detection of annihilation gammas (511 keV) from positron emitters. Detection efficiency of 4.2 percent per detector and spatial resolution of 6 to 7 mm FWHM at the mid-plane were achieved. The present camera operates at a maximum count rate of 24 K counts/min, limited by accidental coincidence. The theory for the gamma converter is presented along with a review of the operation of the multiwire proportional chamber and delay line readout. Calculated gamma converter efficiencies are compared with the measured results using a prototype test chamber. The characteristics of the positron camera system is evaluated, and the performance is shown to be consistent with calculation

  1. Imaging with a multiplane multiwire proportional chamber using heavy ion beams

    International Nuclear Information System (INIS)

    Chu, W.T.; Alonso, J.R.; Tobias, C.A.

    1982-01-01

    A 16-plane multiwire proportional chamber has been developed to accurately map intensity profiles of heavy ion beams at the Bevalac. The imaging capability of the system has been tested for reconstruction of 3-dimensional representation of a canine thorax region using heavy ion beams

  2. Multiwire proportional counter (lecture by an electromagnetic delay line)

    International Nuclear Information System (INIS)

    Bruere-Dawson, R.

    1989-01-01

    For track localisation of ionizing particles with multiwire proportional chamber, an electronic chain including amplifying, shaping and memorizing circuits is required for each wire. In order to lower the cost of this type of detector, an electromagnetic delay line is proposed among various possibilities. In this paper, different coupling modes between chamber and delay line are studied with their respective advantages. The realization of one meter long delay line with a unit delay time of 15 ns per cm is also presented [fr

  3. Fast multiwire proportional chamber data encoding system for proton tomography

    International Nuclear Information System (INIS)

    Brown, D.

    1979-01-01

    A data encoding system that rapidly generates the binary address of an active wire in a 512-wire multiwire proportional chamber has been developed. It can accept a second event on a different wire after a deadtime of 130 ns. The system incorporates preprocessing of the wire data to reject events that would require more than one wire address. It also includes a first-in, first-out memory to buffer the data flow

  4. A cylindrical multiwire high-pressure gas proportional chamber surrounding a gaseous $_{2} target with a mylar separation foil $6 \\mu m thick

    CERN Document Server

    Gastaldi, Ugo; Averdung, H; Bailey, J; Beer, G A; Dreher, B; Erdman, K L; Klempt, E; Merle, K; Neubecker, K; Sabev, C; Schwenk, H; Wendling, R D; White, B L; Wodrich, R

    1978-01-01

    The characteristics and performances of a cylindrical multiwire proportional chamber built and used at CERN in experiment S142 for the study of the pp atom spectroscopy are presented. The chamber surrounds a high-pressure gaseous H/sub 2/ target, from which it is separated by a very thin window (6 mu m mylar foil). The active volume (90 cm long; 2 cm thick, internal diameter=30 cm) is divided into 36 equal and independent cells each covering 10 degrees in azimuth. At 4 abs. atm the detection efficiency for X-rays is higher than 20% in the whole energy range 1.5-15 keV. Typical resolutions are 35% fwhm for the 3 ke V Ar fluorescence line and 25% fwhm for the 5.5 keV /sup 54/Mn line. Working pressures from 0.5 to 16 abs. atm have been used. (8 refs).

  5. CWRU multiwire proportional counter readout system

    International Nuclear Information System (INIS)

    Bevington, P.R.; Leskovec, R.A.

    1977-01-01

    An electronic system is described which translates pulses from individual wires of multiwire proportional counters into binary addresses indicating the location of the wires in the chambers. The system combines a fast (<100 ns) serial scan of an event buffer with parallel encoding to provide fast transfer of addresses (250 ns per hit). The buffer has provision for disabling the input less than 40 ns after detection of an event to suppress recording of multiple hits caused by individual events. The encoder can digitize the address of every hit encountered or just the first addresses of contiguous hits. The system includes a coincidence trigger for determining whether timing criteria have been satisfied between chambers and with external devices. Events which do not meet the coincidence criteria are typically reset within 400 ns. The addresses are transferred to a computer interface through CAMAC modules. Multiple buffering permits further data acquisition during CAMAC transfer cycles. (Auth.)

  6. Some simple approaches used in the construction of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Staric, M.; Zavrtanik, D.; Kernel, G.; Ljubljana Univ.

    1983-01-01

    A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mmx160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. (orig.)

  7. Development of a gamma camera based on a multiwire proportional counter

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Zanevskij, Yu.V.; Ivanov, A.B.

    1981-01-01

    The developed high-pressure gamma-chamber based on a gas multiwire detector is discussed. The main characteristics of the detector for a gamma-ray energy of up to 100 keV are given. The chamber operation is possible at a pressure of up to 10 atm. The detector is filled with a Xe-CH 4 (90-10) mixture. The detector efficiency is about 50%, the space resolution is better than 2 mm at a working region of 280x280 mm [ru

  8. A large area two-dimensional position sensitive multiwire proportional detector

    CERN Document Server

    Moura, M M D; Souza, F A; Alonso, E E; Fujii, R J; Meyknecht, A B; Added, N; Aissaoui, N; Cardenas, W H Z; Ferraretto, M D; Schnitter, U; Szanto, E M; Szanto de Toledo, A; Yamamura, M S; Carlin, N

    1999-01-01

    Large area two-dimensional position sensitive multiwire proportional detectors were developed to be used in the study of light heavy-ion nuclear reactions at the University of Sao Paulo Pelletron Laboratory. Each detector has a 20x20 cm sup 2 active area and consists of three grids (X-position, anode and Y-position) made of 25 mu m diameter gold plated tungsten wires. The position is determined through resistive divider chains. Results for position resolution, linearity and efficiency as a function of energy and position for different elements are reported.

  9. Printed low velocity delay lines for cathode readout of proportional chambers

    International Nuclear Information System (INIS)

    Bosshard, R.; Chase, R.L.; Fischer, J.; Radeka, V.

    1974-01-01

    A readout which simultaneously insures a correct electric field, a satisfactory induced signal, the delay function itself, and low particle scattering is described for multiwire proportional chambers. (U.S.)

  10. Imaging performance of a multiwire proportional-chamber positron camera

    International Nuclear Information System (INIS)

    Perez-Mandez, V.; Del Guerra, A.; Nelson, W.R.; Tam, K.C.

    1982-08-01

    A new design - fully three-dimensional - Positron Camera is presented, made of six MultiWire Proportional Chamber modules arranged to form the lateral surface of a hexagonal prism. A true coincidence rate of 56000 c/s is expected with an equal accidental rate for a 400 μCi activity uniformly distributed in a approx. 3 l water phantom. A detailed Monte Carlo program has been used to investigate the dependence of the spatial resolution on the geometrical and physical parameters. A spatial resolution of 4.8 mm FWHM has been obtained for a 18 F point-like source in a 10 cm radius water phantom. The main properties of the limited angle reconstruction algorithms are described in relation to the proposed detector geometry

  11. Systematic shifts of evaluated charge centroid for the cathode read-out multiwire proportional chamber

    International Nuclear Information System (INIS)

    Endo, I.; Kawamoto, T.; Mizuno, Y.; Ohsugi, T.; Taniguchi, T.; Takeshita, T.

    1981-01-01

    We have investigated the systematic error associtated with the charge centroid evaluation for the cathode read-out multiwire proportional chamber. Correction curves for the systematic error according to six centroid finding algorithms have been obtained by using the charge distribution calculated in a simple electrostatic mode. They have been experimentally examined and proved to be essential for the accurate determination of the irradiated position. (orig.)

  12. Contributions to the methodology of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Petrascu, H.

    1993-01-01

    The Ph.D. thesis presents first the realization, testing, optimization, and use of detection equipment based on position sensitive multiwire proportional chambers (MWPC), high resolution proportional counters, and of ΔE,E ionization chambers. In the second chapter it is presented the realization MWPC, in which the coordinate information is obtained by means of LC-delay lines, containing many original constructive elements. By using a system of three MWPC in coincidence, an experimental testing of the theoretically predicted pion generation in the 235 U fission process, was performed. An upper limit of 10 -11 for this process was found. In the 3-rd chapter there are presented the developments of high resolution proportional counters for X-ray spectrometry. Various penning mixtures of high purity gases were studied. The purity of gases was assured by a technology described in a Romanian patents. These counters are currently use in various applications as a rapid analysis of steel marks and in the mining industry. the 4-th chapter is dedicated to the construction and using of ΔE,E closed, high resolution ionization chambers. With these chambers the multinucleon transfer in the 27 Al( 14 M, X) reaction at 116 MeV bombarding energy was investigated. Also this type of chambers was used for the elaboration of an absolute method for analysis and profiling of impurities in silicon wafers. This method is described in the last part of the chapter. (Author) 117 Figs., 8 Tabs., 55 Refs

  13. Application of multiwire proportional chamber in BEPC test beam

    International Nuclear Information System (INIS)

    Shen Ji; Chen Ziyu; Ye Yunxiu; Cuiu Xiangzong; Li Jiacai

    2006-01-01

    This paper describes a Multiwire Proportional Chamber (MWPC) for the Test Beam on BEPC (Beijing Electron Positron Colider). The distance between the anode surface and the cathode surface of the MWPC is 6 mm. Both surfaces are made of gold-plated tungsten wires, the anode wires are 20 μm in diameter and 2 mm apart, and the cathode wires are 50 μm indiameter and 0.7 mm apart. Six adjacent wires are connected together to form a 4.2 mm wide cathode strip. The MWPC can localize the particles of e, π by cathode-induced charge centre-of-gravity read-out. For 5.9 keV γ photon, the positional resolution is less than 0.3 mm (FWHM) and for 1.1 GeV beam electron, 0.224 mm (FWHM) positional resolution is attained. (authors)

  14. The Rutherford Appleton Laboratory's Mark I Multiwire Proportional Counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1983-01-01

    A small model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on Multiwire Proportional Counter technology it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. A complete hardware system and sufficient software was provided to permit hospital based colleagues to generate useful images easily. A complete description of the system is given with performance figures and some of the images obtained are presented. (author)

  15. Industrial defectoscope based on multiwire proportional chamber in CAMAC system

    International Nuclear Information System (INIS)

    Brzeski, P.; Kazubek, M.; Mirkowski, J.; Szabatin, R.

    1976-01-01

    The defectoscope for non-destructive testing has been built at the Institute of Radioelectronics in collaboration with the Electrotechnical Institute, Non-destructive Division. The defectoscope consists of the following parts: gamma radiation detector, multiwire proportional chamber with γ-e converter, preamplifier system attached directly to the chamber wires, logic module of CAMAC philoscopy, and MERA 300 minicomputer. The defectoscope is used to detect material flaws in tested objects, irradiated from an internal radiation source. Minicomputer used enables data processing. The data collected in mincomputer memory are the radiological image of a tested object. It is possible to display the collected image on a television monitor, to display any profile of the image on an oscilloscope, to print the map of the image on a mosaic printer. (author)

  16. A hybrid multiwire proportional-drift chamber for use in gamma-ray astronomy

    International Nuclear Information System (INIS)

    Crannell, H.; Maurer, G.S.

    1977-01-01

    The direction of an incident high-energy gamma ray can be determined by accurately measuring the direction of the electron-positron pair created by the photon conversion. The operation of a hybrid multiwire-drift proportional chamber is described. Track position is obtained to within a small fraction of the anode wire spacing over a wide range of incident angles. Both track position and angle information are obtained from a single anode-plane crossing. A method of employing a multiple delay-line readout to obtain the position and direction of both members of an electron-positron pair

  17. Multiwire area x-ray diffractometers

    International Nuclear Information System (INIS)

    Hamlin, R.

    1985-01-01

    The multiwire proportional counter is at this writing the only type of two-dimensional position-sensitive X-ray detector capable of collecting diffraction data accurate enough for solution of new protein structures. The first diffractometer system to use this type of detector (the Mark I diffractometer system) was assembled at the University of California, San Diego and has collected the data used to solve for four new protein structures. Similar diffractometer systems using a single thin, flat multiwire counter are now being constructed in several other laboratories around the world, and several of these should routinely be collecting good diffraction data from protein and perhaps even virus crystals by 1986. A table describing some of these other systems is included later in this chapter. The next step in the evolution of area diffractometer systems based on the multiwire proportional counter is more complete coverage of the solid angle of the diffraction pattern - more complete than the 10 - 40% coverage possible with one flat multiwire counter. The phenomenon called ''parallax'' makes it impractical to intercept the whole diffraction pattern with one flat, xenon-filled multiwire counter. Two strategies for dealing with parallax are now being pursued. One strategy involves adding a spherical drift region to the front of a flat multiwire counter and a detector using this idea will be described. The other strategy, one being pursued by the author, involves building an array of flat detectors arranged to approximate a section of the surface of a sphere. The array of flat detectors gives more flexibility in crystal-to-detector distance and distributes the dead time over many detectors, thereby allowing the full array to have a high counting rate capacity even using only medium speed (2 μsec) position readout circuits for each individual detector

  18. Multiwire proportional gamma camera for imaging /sup 99/Tcsup(m) radionuclide distributions

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, J E; Connolly, J F [Science Research Council, Chilton (UK). Rutherford Lab.

    1978-05-01

    A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm) showing good imaging of /sup 99/Tcsup(m) radionuclide distributions and confirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area > approximately 3 1m/sup 2/, a quantum efficiency of 15% and a spatial resolution approximately 3 mm, whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronics industry. This apparatus is covered by patent application number 26595/77.

  19. A multiwire proportional gamma camera for imaging 99Tcsup(m) radionuclide distributions

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.

    1978-01-01

    A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm) showing good imaging of 99 Tcsup(m) radionuclide distributions and confirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area > approximately 3 1m 2 , a quantum efficiency of 15% and a spatial resolution approximately 3 mm, whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronics industry. This apparatus is covered by patent application number 26595/77. (author)

  20. Georges Charpak and his multiwire chamber

    CERN Multimedia

    1970-01-01

    In 1968, Georges Charpak developed the 'multiwire proportional chamber', a gas-filled box with a large number of parallel detector wires, each connected to individual amplifiers. Linked to a computer, it could achieve a counting rate a thousand times better than existing techniques - without a camera in sight. From left to right, Georges Charpak, Fabio Sauli and Jean-Claude Santiard working on a multiwire chamber in 1970.

  1. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  2. A suspended boron foil multi-wire proportional counter neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-11

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 µm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the {sup 10}B(n,α){sup 7}Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal–neutron detection efficiency for enriched {sup 10}B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  3. A suspended boron foil multi-wire proportional counter neutron detector

    Science.gov (United States)

    Nelson, Kyle A.; Edwards, Nathaniel S.; Hinson, Niklas J.; Wayant, Clayton D.; McGregor, Douglas S.

    2014-12-01

    Three natural boron foils, approximately 1.0 cm in diameter and 1.0 μm thick, were obtained from The Lebow Company and suspended in a multi-wire proportional counter. Suspending the B foils allowed the alpha particle and Li ion reaction products to escape simultaneously, one on each side of the foil, and be measured concurrently in the gas volume. The thermal neutron response pulse-height spectrum was obtained and two obvious peaks appear from the 94% and 6% branches of the 10B(n,α)7Li neutron reaction. Scanning electron microscope images were collected to obtain the exact B foil thicknesses and MCNP6 simulations were completed for those same B thicknesses. Pulse-height spectra obtained from the simulations were compared to experimental data and matched well. The theoretical intrinsic thermal-neutron detection efficiency for enriched 10B foils was calculated and is presented. Additionally, the intrinsic thermal neutron detection efficiency of the three natural B foils was calculated to be 3.2±0.2%.

  4. System of multiwire proportional chambers at the separated particle channel for the Mirabelle bubble chamber

    International Nuclear Information System (INIS)

    Bryukhanov, N.S.; Galyaev, N.A.; Kotov, V.I.; Prosin, B.V.; Romanov, Yu.A.; Khodyrev, Yu.S.

    1980-01-01

    A system of multiwire proportional chambers (MPC) operating on-line with a M-6000 computer used during tuning and monitoring of beam parameters in a separated particle channel for the Mirabelle bubble chamber is described. Peculiarities of the construction and main characteristics of two MPC versions are considered. The first version is intended for placing in a vacuum at the edges of high-frequency separator deflector, the second one - for placing outside a vacuum in ionoguide gaps. Power supply of the proportional chambers is carried out from local compact (160x95x50 mm) high-voltage sources remotely controlled from a channel panel by low voltage. A MPC position diagram in the accelerator channel, flowsheet of registering electronics for the MPC system, main circuits of high-voltage power source, analog-to-digital converter of a code and trunk amplifier are given. A graph of amplifier signal amplitude dependence on high voltage of a chamber for a different composition of a gaseous mixture is presented. It is noted that the used elements of the electronic system provide the reliable processing of data and its transmission for a great distance (approximately 400 m). It is underlined that the MPC system operation for a long time has shown its high efficiency and reliability

  5. Glow discharge, its sensitivity to infra-red radiation. Observations made during the testing of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Marsh, J.B.; Souten, K.H.; O'Hagan, B.

    1979-05-01

    It has been shown that under glow discharge conditions, multiwire proportional chambers are sensitive to infra-red radiation. Discharge current measurements and light change measurements have been made and the effect of the input window on the output signal and the importance of the finish of the anode and HT wires have been investigated. From these observations it would appear that a glow discharge in the form detailed in this report is sensitive to infra-red radiation though work is still required to optimise the parameters of such a device for IR detection or solar cell technology. (UK)

  6. The Rutherford Appleton Laboratory's Mark I multiwire proportional counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1984-01-01

    A small (30 cmx30 cm) model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on multiwire proportional counter technology, it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. This has permitted evaluation of this type of positron imaging system in the clinical environment using both cyclotron generated isotopes ( 15 O, 11 C, 18 F, 124 I) and available isotopic generator systems ( 82 Rb, 68 Ga). AT RAL we provided a complete hardware system and sufficient software to permit our hospital based colleagues to generate useful images with the minimum of effort. A complete description of the system is given with performance figures and some of the images obtained in three hospital visits are presented. Some detailed studies of the imaging performance of the positron camera are reported which have bearing on the design of future, improved systems. (orig.)

  7. Proportional chambers and multiwire drift chambers at high rates

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1977-01-01

    The high event and particle rates expected for ISABELLE intersecting storage rings raise the question whether PWC's and drift chambers, now widely in use in experiments, still can operate under such conditions. Various effects depend on the number of avalanches produced per length of wire N and the size of the avalanche Q, i.e., on the number of positive ions created in an avalanche. Therefore the important parameter for the following discussion is the product QN. The minimum Q is determined by the type and noise level of preamplifiers used. Examples are given for a typical low noise amplifier as well as for a typical integrated ''cheap'' amplifier. The rate/wire length N depends on the chamber arrangement, wire spacing, etc. In multiwire drift chambers, a single wire shows space-charge effects reducing the pulse height by 1% at a rate of N = 7 x 10 3 mm -1 sec -1 . At a rate of N approximately equal to 10 5 mm -1 sec -1 an efficiency loss of the order of 1% was noticed. The aging effect due to deposits on the anode wire can be reduced using low noise amplifiers and low gas gain to such an extent that a lifetime of about half a year at ISABELLE can be expected. The use of conventional cheap preamplifiers will result in a typical lifetime of about 30 days. Improvements are probable. The time resolution of Δt/sub r/ = 4 nsec fwhm seems adequate for event rates of 10 7 sec -1 . The memory time Δt/sub m/ greater than or equal to 100 nsec may cause serious problems for pattern recognition depending on layout and readout. The use of induced signals on cathode pads, thus reading out shorter parts of the wire, can solve the problem

  8. Multiwire proportional chambers with a high spatial resolution for X radiation detection and localization

    International Nuclear Information System (INIS)

    Algre, J.-L.

    1975-01-01

    A multiwire proportional counter, with a high spatial resolution has been developed, and some basic characteristics of this type of detector specified. A method of calculating the potential and consequently the field at each point of the volume limited by the counter was defined. The method allows the problems of the outer wires to be solved, and the consequences of a wire displacement predicted. The analysis of the pulses observed on both cathode and anode showed that they were hardly formed from the only ion migration from the cathode to the anode. An estimation of the formation time duration established that in argon mixtures with a low percentage of methane, Ar + ions are in majority. Then it can be predicted that anode wires are not to be spaced by less than 1mm when a conventional electronics is used. The study of the multiplication factor as a function of the main geometric parameters of the counter gave a relation between the multiplication coefficient and the geometric parameters of the chamber; consequently the optimal operation conditions can be predicted. Especially, the diameter of the multiplying wires must be as weak as possible to improve the energy resolution of the detector. A localization method showed that an interpolation may be done between two wires so that, with 1mm spaced wires, the two-dimensional position of an event can be determined with a resolution better than 0.5mm for both directions [fr

  9. From the High Energy Physics Laboratory to the hospital -some experiences of the application of MWPC [multiwire proportional counter] technology to medicine

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1989-01-01

    In this talk I wish to briefly review the experience we have obtained at the Rutherford Appleton Laboratory over the past decade in the adaptation of MWPC (multiwire proportional counter) technology to diagnostic imaging applications in medicine. A cursory glance at the history of science and technology quickly shows the often intimate and mutually beneficial relationship between ''pure'' science (and scientists) and practical applications. The following talk traces some of the principal features of the situation which have been brought to my attention in the course of the last decade. (author)

  10. Multi-wire chamber system for heavy ion beam monitoring at the Bevalac

    International Nuclear Information System (INIS)

    Cuperus, J.; Morgado, R.

    1975-03-01

    Horizontal and vertical integrated beam-current profiles are generated by a system of multi-wire chambers (32 wires/profile) operating in either the ionization or proportional mode. Sixteen distinct displays (1024 words) are digitally stored and any four may be simultaneously displayed. A new display can be generated at 64 ms intervals. A central control unit selects the mode of operation, the amount of delay after an appropriate trigger, the chamber integration time, and the particular chambers to be displayed. Operating in the proportional mode, the system can detect relativistic heavy-ion beam intensities as low as 10 4 charges cm -2 sec -1 . (U.S.)

  11. Study and full simulation of ten different gases on sealed Multi-Wire Proportional Counter (MWPC) by using Garfield and Maxwell codes

    International Nuclear Information System (INIS)

    Shohani, M. Ebrahimi; Golgoun, S.M.; Aminipour, M.; Shabani, A.; Mazoochi, A.R.; Akbari, R. Maghsoudi; Mohammadzadeh, M.; Davarpanah, M.R.; Sardari, D.; Sadeghi, M.; Mofrad, F. Babapour; Jafari, A.

    2016-01-01

    In this research gas sealed Multi-Wire Proportional Counter (MWPC) including blades between anode wires and beta particles of "9"0Sr with 196 keV mean energy were considered. Ten different gases such as Noble gases mixtures with methane and several other pure gases were studied. In this type of detector, by using Garfield and Maxwell codes and for each of the gases, variation of different parameters such as first Townsend, electron attachment coefficients with variable electric field and their effects on pulse height or collected charge and in turn on Signal to Noise Ratio (SNR) were studied. Also the effect of anode voltage and its diameter and the pressure of gas on the pulse height were studied. Results show that Garfield and Maxwell codes can be used to study and improve the design of other gaseous detectors. - Highlights: • Simulation of different gases that is applicable for various gas detectors. • Two simulation codes were used and analyzed their results for beta particle. • Different detector parameters were studied (SNR, first Townsend, electron attachment coefficients, anode voltage and etc.). • The effect of blade in the detector were assessed. • The codes are useful for design and improvement of detector.

  12. Multiwire proportional chambers in the triggering system of the streamer chamber for high-Pt charged particle production detection in 40 GeV/c hadron-nucleus interactions

    International Nuclear Information System (INIS)

    Czyrkowski, H.; Dabrowski, R.; Derlicki, A.

    1985-01-01

    We describe a triggering system based on the multiwire proportional chambers (MWPCs) for the high-P t charged particles selection in Π - A interactions at 40 GeV/c (RISC experiment). The coincidence matrices processing only combinations of hits in MWPCs allow one to reach sufficient purity of experimental material. The large area MWPCs work close to the streamer chamber high voltage electrode without any problems. Details of the fabrication procedure and peformances are also given. 12 refs. (author)

  13. Multi-stage low-pressure avalanche chamber

    International Nuclear Information System (INIS)

    Zanevskij, Yu.V.; Peshekhonov, V.D.; Smykov, L.P.

    1985-01-01

    A multi-stage avalanche-chamber filled with isobutane operating at the pressure of 6 torr is described. The chamber comprises an amplifying gap, drift gap and multiwire proportional chamber with interelectrode gaps equal to 4 mm. The anode plane of the proportional chamber is winded of wire 2 μm in diameter with 2 mm pitch. The cathode are winded orthogonally to anode wires of wire 50 μm in diameter with 1 mm pitch. Drift and preamplifier gaps are formed by grid electrodes made of wire 50 μm in diameter with dimension of the cell equal to 1x1 mm. Width of the drift gap is 5 mm, width of the preamplification gap is 3 or 9 mm. Coordinate data are removed from the cathodes of the proportional chamber by means of delay lines. Sensitive square of the chamber equals 240x180 mm. Gas gain coefficient is 3x10 6 at its square nonuniformity equal to approximately 3%. Spatial resolution by both coordinates equals 170 μm; spatial resolution for isotropic α-emitters located close to the preamplifier gap is equal to 500 μm

  14. Cerebral imaging using 68Ga DTPA and the U.C.S.F. multiwire proportional chamber positron camera

    International Nuclear Information System (INIS)

    Hattner, R.S.; Lim, C.B.; Swann, S.J.; Kaufman, L.; Perez-Mendez, V.; Chu, D.; Huberty, J.P.; Price, D.C.; Wilson, C.B.

    1975-12-01

    A multiwire proportional chamber positron camera consisting of four 48 x 48 cm 2 detectors linked to a small digital computer has been designed, constructed, and characterized. Initial clinical application to brain imaging using 68 Ga DTPA in 10 patients with brain tumors is described. Tomographic image reconstruction is accomplished by an algorithm determining the intersection of the annihilation photon paths in planes of interest. Final image processing utilizes uniformity correction, simple thresholding, and smoothing. The positron brain images were compared to conventional scintillation brain scans and x-ray computerized axial tomograms (CAT) in each case. The positron studies have shown significant mitigation of confusing superficial activity resulting from craniotomy in comparison to conventional brain scans. Central necrosis of lesions observed in the positron images, but not in the conventional scans, has been confirmed in CAT. Modifications of the camera are being implemented to improve image quality, and these changes combined with the tomography inherent in the positron scans are anticipated to result in images superior in information content to conventional brain scans

  15. Applications of a Ga-68/Ge-68 generator system to brain imaging using a multiwire proportional chamber positron camera

    International Nuclear Information System (INIS)

    Hattner, R.S.; Lim, C.B.; Swann, S.J.; Kaufman, L.; Chu, D.; Perez-Mendez, V.

    1976-01-01

    A Ge-68/Ga-68 generator system has been applied to brain imaging in conjunction with a novel coincidence detection based positron camera. The camera consists of two opposed large area multiwire proportional chamber (MWPC) detectors interfaced to multichannel lead converter plates. Event localization is effected of delay lines. Ten patients with brain lesions have been studied 1-2 hours after the administration of Ga-68 formulated as DTPA. The images were compared to conventional brain scans, and to x-ray section scans (CAT). The positron studies have shown significant mitigation of confusing superficial activity resulting from craniotomy compared to conventional brain scans. Central necrosis of lesions observed in positron images, but not in the conventional scans has been confirmed in CAT. The economy of MWPC positron cameras combined with the ideal characteristics of the Ge-68/Ga-68 generator promise a cost efficient imaging system for the future

  16. An integrated photosensor readout for gas proportional scintillation counters

    International Nuclear Information System (INIS)

    Lopes, J.A.M.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    A xenon gas proportional scintillation counter has been instrumented with a novel photosensor that replaces the photomultiplier tube normally used to detect the VUV secondary scintillation light. In this implementation, the collection grid of a planar gas proportional scintillation counter also functions as a multiwire proportional chamber to amplify and detect the photoelectrons emitted by a reflective CsI photocathode in direct contact with the xenon gas. This integrated concept combines greater simplicity, compactness, and ruggedness (no optical window is used) with low power consumption. An energy resolution of 12% was obtained for 59.6 keV x-rays

  17. A high-pressure MWPC detector for crystallography

    DEFF Research Database (Denmark)

    Ortuno-Prados, F.; Bazzano, A.; Berry, A.

    1999-01-01

    The application of the Multi-Wire Proportional Counter (MWPC) as a potential detector for protein crystallography and other wide-angle diffraction experiments is presented. Electrostatic problems found with our large area MWPC when operated at high pressure are discussed. We suggest that a solution...

  18. Adaptation of multiwire chambers to some recent experiments in elementary particle physics

    International Nuclear Information System (INIS)

    Comby, G.

    1977-01-01

    Three realizations of gas multiplication detectors are presented in the field of multiwire chambers. Le 'NEUTRINO' experiment is intended for investigating neutrino interactions at energies as high as possible with using drift chambers. The 'LEZARD' experiment is intended for investigating lepton and hadron production at high transverse momentum in hadron-nucleon collisions up to the higher energies attainable at SPS (use of a multiwire proportional chamber), the apparatus has the performance of a spectrometer. A spark chamber equipped with memories has been developed for controlling bubble chamber experiments. Emphasis is put on the evolution towards detectors associated with 'another thing' to obtain a more specific operation: such as the plasma memory and spark chamber association, some possible association with function gaps is pointed out (delay function, homothetic function) [fr

  19. Computed tomographic reconstruction of beam profiles with a multi-wire chamber

    International Nuclear Information System (INIS)

    Alonso, J.R.; Tobias, C.A.; Chu, W.T.

    1979-03-01

    MEDUSA (MEdical Dose Uniformity SAmpler), a 16 plane multi-wire proportional chamber, has been built to accurately measure beam profiles. The large number of planes allows for reconstruction of highly detailed beam intensity structures by means of Fourier convolution reconstruction techniques. This instrument is being used for verification and tuning of the Bevalac radiotherapy beams, but has potential applications in many beam profile monitoring situations

  20. A Logarithmic Detection System Suitable for a 4π Array

    NARCIS (Netherlands)

    Westfall, G.D.; Yurkon, J.E.; Plicht, J. van der; Koenig, Z.M.; Jacak, B.V.; Fox, R.; Crawley, G.M.; Maier, M.R.; Hasselquist, B.E.; Tickle, R.S.; Horn, D.

    1985-01-01

    A low pressure multiwire proportional counter, a Bragg curve counter, and an array of CaF2/plastic scintillator telescopes have been developed in a geometry suitable for close packing into a 4π detector designed to study nucleus-nucleus reactions at 100-200 MeV/nucleon. The multiwire counter is

  1. Study and construction of an air proportional counter for superficial alpha contamination

    International Nuclear Information System (INIS)

    Cabral, T.S.

    1991-01-01

    Some properties of the proportional counters such as the working principle and the process of the gaseous multiplication are presented. Besides that, the project of Multiwire Proportional Counters is shown, which was tested with anodic wires of different diameters and with windows of several thicknesses. Operational characteristics of the detector were determined with the quoted variations. The chamber was normally operated by atmospheric pressure, but there were also made surveys on its behavior with oxygen, nitrogen and mixture of both. The performance of the chamber with a variations of temperature and relative humidity is analysed, because that is one of the biggest problems faced when measure of field are being made with this kind of detector. (author)

  2. Multiwire proportional chamber for Moessbauer spectroscopy: development and results

    International Nuclear Information System (INIS)

    Costa, M.S. da.

    1985-12-01

    A new Multiwere proportional Chamber designed for Moessbauer Spectroscopy is presented. This detector allows transmission backscattering experiments using either photons or electrons. The Moessbauer data acquisition system, partially developed for this work is described. A simple method for determining the frontier between true proportional and semi-proportional regions of operation in gaseous detectors is proposed. The study of the tertiary gas mixture He-Ar-CH 4 leads to a straight forward way of energy calibration of the electron spectra. Moessbauer spectra using Fe-57 source are presented. In particular those obtained with backsattered electrons show the feasibility of depth selective analysis with gaseous proportional counters. (author) [pt

  3. Hydrogen high pressure proportional drift detector

    International Nuclear Information System (INIS)

    Arefiev, A.; Balaev, A.

    1983-01-01

    The design and operation performances of a proportional drift detector PDD are described. High sensitivity of the applied PAD makes it possible to detect the neutron-proton elastic scattering in the energy range of recoil protons as low as 1 keV. The PDD is filled with hydrogen up to the pressure at 40 bars. High purity of the gas is maintained by a continuously operating purification system. The detector has been operating for several years in a neutron beam at the North Area of the CERN SPS

  4. Development of extruded resistive plastic tubes for proportional chamber cathodes

    International Nuclear Information System (INIS)

    Kondo, K.

    1982-01-01

    Carbon mixed plastic tubes with resistivity of 10 3 approx. 10 4 Ωcm have been molded with an extrusion method and used for the d.c. cathode of a proportional counter and a multi-wire proportional chamber. The signal by gas multiplication was picked up from a strip r.f. cathode set outside the tube. The characteristics of the counter in the proportional and limited streamer modes have been studied

  5. The Microstructure of Multi-wire U-Mo Monolithic Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Sang; Park, Eun Kee; Cho, Woo Hyoung; Park, Jong Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    In order to use low-enriched uranium (LEU) instead of highly enriched uranium (HEU) for high performance research reactors, the reduced enrichment for research and test reactors (RERTR) program is developing high uranium density fuel such as U-Mo/Al dispersion fuel. U-Mo alloys have an excellent irradiation performance when compared to other uranium alloys or compounds. But the results from the post-irradiation examination of the U-Mo/Al dispersion fuels indicate that an interaction between the U-Mo alloy fuel and the Al matrix phases occurs readily during an irradiation and it is sensitively dependent on the temperature. In order to lessen these severe interactions, a concept of a multi-wire type fuel was proposed. The fuel configuration is that three to six U-Mo fuel wires (1.5 mm {approx} 2 mm in diameter) are symmetrically arranged at the periphery side in the Al matrix as shown. This multi-wire fuels showed very good fuel performance during the KOMO-3 irradiation test. At the KOMO-3 test, the specimen of the multi-wire fuels were U-7Mo/Al and U-7Mo-1Si/Al. In this study we investigate the microstructure change of the U-7Mo and U-7Mo-1Ti with some variation of annealing conditions. In addition to this, we want to check the effect of adding Ti element to U-7Mo on the gamma phase stability

  6. 2-D Low Energy Electron Beam Profile Measurement Based on Computer Tomography Algorithm with Multi-Wire Scanner

    CERN Document Server

    Yu, Nengjie; Li Qing Feng; Tang, Chuan-Xiang; Zheng, Shuxin

    2005-01-01

    A new method for low energy electron beam profile measurement is advanced, which presents a full 2-D beam profile distribution other than the traditional 2-D beam profile distribution given by 1-D vertical and horizontal beam profiles. The method is based on the CT (Computer Tomography) algorithm. Multi-sets of data about the 1-D beam profile projections are attained by rotating the multi-wire scanner. Then a 2-D beam profile is reconstructed from these projections with CT algorithm. The principle of this method is presented. The simulation and the experiment results are compared and analyzed in detail.

  7. Contribution of custom-designed integrated circuits to the electronic equipment of multiwire chambers

    International Nuclear Information System (INIS)

    Prunier, J.

    1977-01-01

    The first generations of circuits intended to equip the multiwire proportional chambers provided the user with logical type indications (absence or presence of a signal at a given place). This logical indication was soon associated with a semi-analog data (presence or absence of a signal above an analog threshold, i.e. the discrimination function) as with FILAS, RBA and RBB circuits. The evolution continued with the appearance of analog data capture (time, amplitude, charge) and the corresponding circuits: IFT circuits, analog-to-digital converters [fr

  8. A multi-wire beam profile monitor in the AGS

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H.; Buxton, W.; Castillo, V.; Glenn, J.W. [and others

    1997-07-01

    A multi-wire beam profile monitor which can be used to directly monitor and control the optical matching between the Booster and AGS rings has been installed and tested in the AGS. Placement of a multi-wire monitor directly in the AGS provides profile measurements taken upon injection and the first two or more revolutions of the beam. The data from such measurements can be used to determine the optical properties of the beam transport line leading into the AGS.

  9. proportional counting chamber for large-area-coated β sources

    Indian Academy of Sciences (India)

    The system consists of a multiwire-based proportional counter with gas ... volume of the detector to avoid any loss of detection efficiency due to absorption in the entrance ... Figure 1. (a) Energy levels of 90Sr decay scheme and (b) energy distribution of β- ... High voltage is applied to the anode grid and high electric field is.

  10. Digital imaging with a pressurized Xenon filled MWPC working at a high data rate

    International Nuclear Information System (INIS)

    Bellazzini, R.; Brez, A.; Del Guerra, A.; Massai, M.M.; Torquati, M.R.; Franchi, M.; Perri, G.

    1984-01-01

    A multiwire proportional chamber based detection system for medical imaging is presented. The system consists of a pressurized xenon filled MWPC and of a monochromatic fluorescent, X-ray source using a conventional diagnostic tube with various target filter combinations. The main performance of the system are: 10% efficiency, 30% energy resolution 500 micro m spatial resolution, +-5 uniformity. The preliminary results of the application of this system to bone densitometry are presented

  11. Development of Proportional Pressure Control Valve for Hydraulic Braking Actuator of Automobile ABS

    Directory of Open Access Journals (Sweden)

    Che-Pin Chen

    2018-04-01

    Full Text Available This research developed a novel proportional pressure control valve for an automobile hydraulic braking actuator. It also analyzed and simulated solenoid force of the control valves, and the pressure relief capability test of electromagnetic thrust with the proportional valve body. Considering the high controllability and ease of production, the driver of this proportional valve was designed with a small volume and powerful solenoid force to control braking pressure and flow. Since the proportional valve can have closed-loop control, the proportional valve can replace a conventional solenoid valve in current brake actuators. With the proportional valve controlling braking and pressure relief mode, it can narrow the space of hydraulic braking actuator, and precisely control braking force to achieve safety objectives. Finally, the proposed novel proportional pressure control valve of an automobile hydraulic braking actuator was implemented and verified experimentally.

  12. A multiwire proportional counter for very high counting rates

    International Nuclear Information System (INIS)

    Barbosa, A.F.; Guedes, G.P.; Tamura, E.; Pepe, I.M.; Oliveira, N.B.

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10 6 counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10 7 events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author)

  13. A multiwire proportional counter for very high counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, A F; Guedes, G P [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Tamura, E [Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, SP (Brazil); Pepe, I M; Oliveira, N B [Bahia Univ., Salvador, BA (Brazil). Inst. de Fisica

    1997-12-01

    Preliminary measurements in a proportional counter with two independently counting wires showed that counting rates up to 10{sup 6} counts/s per wire can be reached without critical loss in the true versus measured linearity relation. Results obtained with a detector containing 30 active wires (2 mm pitch) are presented. To each wire is associated a fast pre-amplifier and a discriminator channel. Global counting rates in excess to 10{sup 7} events/s are reported. Data acquisition systems are described for 1D (real time) and 2D (off-line) position sensitive detection systems. (author) 13 refs., 6 figs.

  14. Swelling Estimation of Multi-wire U-Mo Monolithic Fuel for HANARO Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon-Sang; Ryu, Ho-Jin; Park, Jong-Man; Oh, Jong-Myeong; Kim, Chang-Kyu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-10-15

    In order to use low-enriched uranium (LEU) instead of highly enriched uranium (HEU) for high performance research reactors, the reduced enrichment for research and test reactors (RERTR) program is developing high uranium density fuel such as U-Mo/Al dispersion fuel. U-Mo alloys have an excellent irradiation performance when compared to other uranium alloys or compounds. But the results from the post-irradiation examination of the U-Mo/Al dispersion fuels indicate that an interaction between the U-Mo alloy fuel and the Al matrix phases occurs readily during an irradiation and it is sensitively dependent on the temperature. In order to lessen these severe interactions, a concept of a multi-wire type fuel was proposed. The fuel configuration is that three to six U-Mo fuel wires (1.5 mm - 2 mm in diameter) are symmetrically arranged at the periphery side in the Al matrix. In this study temperature calculations and a swelling estimation of a multi-wire monolithic fuel were carried out. Also the results of a post irradiation analysis of this fuel will be introduced.

  15. Optimization of multiwire coil ends having 45 degree bends

    International Nuclear Information System (INIS)

    Morgan, G.H.

    1989-01-01

    Multiwire is the name of a proprietary process for affixing small diameter wires to a flat substrate using digitally controlled machinery. It is currently being used to wind trim coils for the SSC dipoles on a flexible substrate which is wrapped around the beam tube. It is proposed for making multipole coils for the Corrector, a regular arc magnet in each half-cell of the Relativistic Heavy Ion Collider (RHIC). The current Multiwire process does not permit a change in direction of the wire other than 45 degree. The present paper answers the question of whether the 45 degree bends in the flattened coil can be located along straight lines in such a way as to eliminate or reduce higher harmonics in the ends. The more general question of bends located along curves is not addressed

  16. Optimization of multiwire coil ends having 45 degree bends

    International Nuclear Information System (INIS)

    Morgan, G.H.

    1988-01-01

    Multiwire is the name of a proprietary process for affixing small diameter wires to a flat substrate using digitally controlled machinery. It is currently being used to wind trim coils for the SSC dipoles on a flexible substrate which is wrapped around the beam tube. It is proposed for making multipole coils for the Corrector, a regular arc magnet in each half-cell of the Relativistic Heavy Ion Collider (RHIC). The current Multiwire process does not permit a change in direction of the wire other than 45 degree. The present paper answers the question of whether the 45 degree bends in the flattened coil can be located along straight lines in such a way as to eliminate or reduce higher harmonics in the ends. The more general question of bends located along curves is not addressed. 3 refs., 3 figs., 2 tabs

  17. Proportional positive airway pressure: a new concept to treat obstructive sleep apnoea.

    Science.gov (United States)

    Juhász, J; Becker, H; Cassel, W; Rostig, S; Peter, J H

    2001-03-01

    Proportional positive airway pressure (PPAP) was designed to optimize airway pressure for the therapy of obstructive sleep apnoea (OSA). In a randomized crossover prospective study, the clinical feasibility of PPAP and its immediate effects on the breathing disorder and sleep in comparison with continuous positive airway pressure (CPAP) was evaluated. Twelve patients requiring CPAP therapy underwent CPAP and PPAP titration in a random order. Obstructive and mixed respiratory events could be completely abolished with both forms of treatment. This efficacy could be achieved at a significantly lower mean mask pressure during PPAP titration (8.45+/-2.42 cmH2O) compared to CPAP (9.96+/-2.7 cmH2O) (p=0.002). The mean minimal arterial oxygen saturation (Sa,O2) (82.8+/-6.5%) on the diagnostic night increased significantly (pPPAP titration. Total sleep time, slow wave sleep and rapid eye movement (REM) sleep increased significantly by the same amount during both CPAP and PPAP titration (pPPAP titration night, four patients did not have a preference, and two patients preferred CPAP. The present data show that proportional positive airway pressure is as effective as continuous positive airway pressure in eliminating obstructive events and has the same immediate effect on sleep. The lower average mask pressure during proportional positive airway pressure implies potential advantages compared to continuous positive airway pressure. Proportional positive airway pressure presents a new effective therapeutic approach to obstructive sleep apnoea.

  18. Comprehensive applications of the gas flow proportional counters for radiological surveillance

    International Nuclear Information System (INIS)

    Babu, D.A.R.; Raman, Anand; Ashokkumar, P.; Sharma, D.N.

    2008-01-01

    Gas Flow Proportional Counters (GFPC) have been developed indigenously for various radiation protection applications. These detectors can be fabricated for 2 inches diameter filter paper sample counting applications to large area (∼1500 cm 2 ) detectors for surface contamination applications. Thin entrance windows allow non penetrating type of radiations like alpha and low energy beta particles, Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. Poor gamma efficiency ( 2 /γ ratio, a high figure of merit and enables efficient gamma background rejection. These detectors are quite suitable for Indian environmental conditions. Three systems have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. The systems based on GFPC detectors include: a) Multiple sample gross alpha counting system; b) Laundry monitoring system; c) Alpha hand contamination monitoring system. The first of these enables simultaneous gross alpha counting of five air activity filter paper samples. The area of the detector surface is optimized to cover the 2 inches sized filter paper samples routinely used for the purpose. Five numbers of GFPC 's are arranged sequentially coupled to five individual amplifiers - micro controller modules to process the signal from the five counters. The laundry monitor which is micro controller based system consists of four large area multiwire GFPC detectors (700 cm 2 sensitive area) used to monitor alpha contamination of decontaminated laundry, Each detector uses a charge sensitive preamplifier coupled to I 2 C counter. The alpha hand monitoring system consists of four large area multiwire gas flow proportional detectors (330 cm 2 sensitive area each). A micro controller-based module is employed to initiate the counting process automatically when the hands are inserted in to the suitably designed window slots and provides audio and

  19. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  20. Radiology utilizing a gas multiwire detector with resolution enhancement

    Science.gov (United States)

    Majewski, Stanislaw; Majewski, Lucasz A.

    1999-09-28

    This invention relates to a process and apparatus for obtaining filmless, radiological, digital images utilizing a gas multiwire detector. Resolution is enhanced through projection geometry. This invention further relates to imaging systems for X-ray examination of patients or objects, and is particularly suited for mammography.

  1. Pressure control valve using proportional electro-magnetic solenoid actuator

    International Nuclear Information System (INIS)

    Yun, So Nam; Ham, Young Bog; Park, Pyoung Won

    2006-01-01

    This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed

  2. The vertex detector of the UA2 experiment (a low mass self sustaining system of cylindrical multiwire proportional chambers)

    International Nuclear Information System (INIS)

    Dialinas, M.; Forget, J.; Geoffroy, D.; Jean, P.; Vergand, M.

    1983-07-01

    The construction of the cylindrical proportional strip chambers of the UA2 vertex detector is reported. The mechanical design, the engineering and the effective realization are described in detail. Possible improvements for the construction of such chambers are also given

  3. FPGA based fast synchronous serial multi-wire links synchronization

    Science.gov (United States)

    Pozniak, Krzysztof T.

    2013-10-01

    The paper debates synchronization method of multi-wire, serial link of constant latency, by means of pseudo-random numbers generators. The solution was designed for various families of FPGA circuits. There were debated synchronization algorithm and functional structure of parameterized transmitter and receiver modules. The modules were realized in VHDL language in a behavioral form.

  4. Two-dimension multiwire detector for ionizing radiation

    International Nuclear Information System (INIS)

    Barberino, Carlos Henrique

    1993-01-01

    A multiwire proportional Counter of 100 x 100 mm 2 sensitive area has been developed. The chamber is formed by three planes: a cathode plane of 50 μm gold coated tungsten wires stretched on an Epoxi frame; and anode plane made of 20 μm gold plated tungsten wires stretched at 45 deg C with respect to the first cathode wires; and second cathode plane made of copper strips on a printed circuit board at 90 deg C with respect to the first cathode. The cathode strips are connected to the taps of delay-lines chips. The position of the incidence of radiation is extracted by measuring the time difference of the pulse arriving at the extremities of the delay-line chain for each coordinate. The performance of the detector has been tested using 5.89 KeV X-rays from a 55 Fe source, and 8.04 KeV from Rigaku X-rays generator, operating the detector with 90% Ar + 10% CH 4 gas mixture at 930 mbar. An energy resolution of 26% was obtained. An integral non linearity better than 0.3% and a position resolution better than 1 mm have been observed. The information corresponding to each one of the coordinates were digitized by a TDC in a CAMAC system and stored event by event in a micro-computer (IBM-AT). (author)

  5. Numerical determination of the amplification of a cylindrical proportional counter operating at low pressure. Application to nano-dosimetry

    International Nuclear Information System (INIS)

    Moutarde, Cyrille

    1994-01-01

    This work is devoted to a study of proportional counters used to measure the energy deposition in micrometer biological sites. Tissue equivalent gas filling improve typical operating mode of those counters. Specially, the extension of the multiplication zone becomes important at low pressures. A Monte Carlo simulation has been used to study the behaviour of an electron swarm in the sensitive volume. The calculations show that electrons are not in equilibrium with the applied electric field in this geometry. The influence of the gradient field and the rotation of the electrons around the anode wire has been studied carefully. The importance of non-equilibrium effects on the theoretical amplification calculated through the ionisation coefficient has been confirmed by experimental investigations. The statistical fluctuations of multiplication process has been calculated by the determination of avalanche spectra at the anode. Resolution of an ultra-miniature counter have been calculated to improve technological limitations of experimental nanodosimetry. (author) [fr

  6. Study on efficiency of multi-wire tungsten moderator for slow positron source on SPring-8 hard synchrotron radiation

    International Nuclear Information System (INIS)

    Plokhoi, Vladimir; Kandiev, Yadgar; Samarin, Sergey; Malyshkin, Gennady; Baidin, Grigory; Litvinenko, Igor; Nikitin, Valery

    1999-01-01

    The paper provides results of numeric simulations of in-target positron production process, processes of moderation, thermalization, diffusion, and reemission of positrons in high efficiency multi-wire moderator made of tungsten monocrystalline wire with regular wire spacing. The paper looks into dynamics of slow positrons in the moderator's vacuum gaps taking into account of external fields. The possibility for using multi-wire moderator with non-regular structure - multi-layer w ire felt m oderator is discussed. According to maximal estimate the multi-wire moderators can reach very high efficiency of fast-slow positron transformation ∼ 10 -2 . Using such moderator the intensity of slow positron source on hard synchrotron radiation of Spring-8 can reach the level of ∼10 11 e + /s. (author)

  7. PPM-based System for Guided Waves Communication Through Corrosion Resistant Multi-wire Cables

    Science.gov (United States)

    Trane, G.; Mijarez, R.; Guevara, R.; Pascacio, D.

    Novel wireless communication channels are a necessity in applications surrounded by harsh environments, for instance down-hole oil reservoirs. Traditional radio frequency (RF) communication schemes are not capable of transmitting signals through metal enclosures surrounded by corrosive gases and liquids. As an alternative to RF, a pulse position modulation (PPM) guided waves communication system has been developed and evaluated using a corrosion resistant 4H18 multi-wire cable, commonly used to descend electronic gauges in down-hole oil applications, as the communication medium. The system consists of a transmitter and a receiver that utilizes a PZT crystal, for electrical/mechanical coupling, attached to each extreme of the multi-wire cable. The modulator is based on a microcontroller, which transmits60 kHz guided wave pulses, and the demodulator is based on a commercial digital signal processor (DSP) module that performs real time DSP algorithms. Experimental results are presented, which were obtained using a 1m corrosion resistant 4H18multi-wire cable, commonly used with downhole electronic gauges in the oil sector. Although there was significant dispersion and multiple mode excitations of the transmitted guided wave energy pulses, the results show that data rates on the order of 500 bits per second are readily available employing PPM and simple communications techniques.

  8. Conception and test of an integrated circuit (ASIC): application to multiwire chambers and photomultipliers of the GRAAL experience

    International Nuclear Information System (INIS)

    Bugnet, H.

    1995-01-01

    The nuclear physics project GRAAL (GRenoble Anneau Accelerateur Laser) located at the European Synchrotron Radiation Facility (ESRF) in Grenoble produces a high energy photon beam with a maximum energy of 1.5 GeV. This gamma beam is obtained by Compton backscattering and can be polarized easily. It permits to probe, in an original way, the structure of the nucleon. The associated detector system includes multiwire proportional chambers and scintillator hodoscopes. A kit of six ASICs (Application Specific Integrated Circuit) has been developed and used for the signal processing and data conditioning up to the level of the data acquisition. This integrated electronics can be mounted right on the detectors. Obvious advantages, due to the reduction of the length of the wires and the number of connections, are an improvement of the signal quality and an increase of the reliability. The Wire Processor (WP), ASIC designed and tested during this thesis, treats the signals from the chamber wires and the photomultipliers. In one chip, there are two identical channels permitting the amplification, the amplitude discrimination, the generation of a programmable delay and the writing in a two state memory in case of coincidence with an external strobe signal. The measurement of the multiwire chamber efficiency demonstrates the functioning of the WP, the data conditioning electronics, the data acquisition and the chamber itself. (author). 62 refs., 111 figs., 13 tabs

  9. Study of the MWPC gas gain behaviour as a function of the gas pressure and temperature

    CERN Document Server

    Pinci, D

    2005-01-01

    The Muon System of the LHCb experiment is composed of five detection stations (M1-M5) equipped with 1368 Multi-Wire Proportional Chambers (MWPC) and 24 Triple-GEM detectors. The Multi Wire Proportional Chamber (MWPC) performances (detection efficiency, time resolution, pad-cluster size and ageing properties) are heavily dependent on the gas gain. The chamber gain depends on the gas density and therefore on the gas temperature and pressure. The impact of the environmental parameters on the MWPC gain has been studied in detail. The results, togheter with a simple method proposed to account for the gain variations, are reported in this note. The absolute gas gain at the testing voltage of 2750 V was also measured to be (1.2 +- 0.1)*10^5.

  10. Multiwire secondary-emission monitor and the emittance measurement of the AGS beam

    International Nuclear Information System (INIS)

    Weng, W.T.; Chiang, I.H.; Smith, G.A.; Soukas, A.

    1983-01-01

    For CBA injection the transverse emittances and the Twiss parameters of the AGS beam have to be well defined to minimize the phase space dilution in CBA. Althoug there exists a profile monitor device at U165, there are three reasons why construction of multiwire profile monitor system at three locations from U500 to U168 is required: (1) the dispersion function is not zero at U165 which makes it harder to interpret the measurement; (2) the original single wire device takes five minutes to traverse the whole beam; (3) a three station multiwire system can provide the profile information at all locations in one pulse which makes on-line analysis possible. In summary, a set of three stations of Multiwire Secondary Emission Monitor (MSEM) has been built and installed in the fast external beam line for the measurement of beam profiles. Each unit consists of two planes each with 30 nickel wires having a diameter of 5 mils. The signal is linear within the range of 10 10 to 10 13 incident protons on the wire and the resolution of the signal is well within a few percent. A least-square fitting routine has been used to extract the emittance and phase space parameters of the beam. The emittances obtained at various intensities will help us to understand the AGS acceleration process and to choose the optimal injection scheme for CBA

  11. Application of the finite-difference approximation to electrostatic problems in gaseous proportional counters

    International Nuclear Information System (INIS)

    Waligorski, M.P.R.; Urbanczyk, K.M.

    1975-01-01

    The basic principles of the finite-difference approximation applied to the solution of electrostatic field distributions in gaseous proportional counters are given. Using this method, complicated two-dimensional electrostatic problems may be solved, taking into account any number of anodes, each with its own radius, and any cathode shape. A general formula for introducing the anode radii into the calculations is derived and a method of obtaining extremely accurate (up to 0.1%) solutions is developed. Several examples of potential and absolute field distributions for single rectangular and multiwire proportional counters are calculated and compared with exact results according to Tomitani, in order to discuss in detail errors of the finite-difference approximation. (author)

  12. Determination of the production rate of low intensity isomeric transitions

    International Nuclear Information System (INIS)

    Lakosi, L.; Veres, A.; Tam, N.C.; Pavlicsek, I.

    1992-01-01

    Flat 2π and cylindrical 4π multiwire proportional counters were built for counting for low energy internal conversion electrons from the nuclear isomers 83m Kr, 103m Rh and 189m Os, induced by irradiation with high intensity 60 Co and 4 MeV bremsstrahlung sources. The β-decay of 176m Lu was recorded by a plastic scintillator. In this way higher sensitivities were attained than by detecting γ-rays or characteristic X-rays associated with the isomeric transitions, and the excitation of 189m Os by low energy 137 Cs and 300 kV X-ray sources also became detectable. Comparatively large isomeric activities produced by linac irradiation were standardizing by a Ge spectrometer for calibrating proportional and scintillation counting. (orig.)

  13. Gain reduction due to space charge at high counting rates in multiwire proportional chambers

    International Nuclear Information System (INIS)

    Smith, G.C.; Mathieson, E.

    1986-10-01

    Measurements with a small MWPC of gas gain reduction, due to ion space charge at high counting rates, have been compared with theoretical predictions. The quantity ln(q/q 0 )/(q/q 0 ), where (q/q 0 ) is the relative reduced avalanche charge, has been found to be closely proportional to count rate, as predicted. The constant of proportionality is in good agreement with calculations made with a modified version of the original, simplified theory

  14. Compact multiwire proportional chambers and electronics for the crystal ball detector

    International Nuclear Information System (INIS)

    Gaiser, J.E.; Liberman, A.D.; Rolfe, J.

    1978-01-01

    A double gap of cylindrical proportional chambers has been designed and built for use with a large solid angle, modular NaI(Tl) array (The Crystal Ball). The chambers are constructed of three coaxial foam-epoxy shells, covered with an aluminum-mylar laminate. One of the high voltage cathodes in each chamber has been photo-etched to produce a pattern of stripes and precise position measurements of tracks passing transverse to the chamber axis are found by pulse height analyzing the shaped and amplified induced strip signals. Performance of the chamber using both the strip signals and the sense wire readout is presented. The design of both the signal handling electronics and the digital portions of the systems is discussed

  15. Timing characteristics of a two-dimensional multi-wire cathode strip detector for fission fragments

    International Nuclear Information System (INIS)

    Vind, R.P.; Joshi, B.N.; Jangale, R.V.; Inkar, A.L.; Prajapati, G.K.; John, B.V.; Biswas, D.C.

    2014-01-01

    In the recent past, a gas filled two-dimensional multi-wire cathode strip detector (MCSD) was developed for the detection of fission fragments (FFs). The position resolution was found to be about 1.0 and 1.5 mm in X and Y directions respectively. The detector has three electrode planes consisting of cathode strip (X-plane), anode wires and split-cathode wires (Y-plane). Each thin wire of the anode plane placed between the two cathode planes is essentially independent and behaves like a proportional counter. The construction of the detector in detail has been given in our earlier paper. The position information has been obtained by employing high impedance discrete delay line read out method for extracting position information in X and Y-directions. In this work, the timing characteristics of MCSD detector are reported to explore the possible use of this detector for the measurement of the mass of the fission fragments produced in heavy ion induced fission reactions

  16. Measurement of the positron-drift time relation of a high-pressure drift chamber

    International Nuclear Information System (INIS)

    Pruefert, W.

    1989-04-01

    As a test of its performance, the measurement of the drift time versus drift distance relation of a high pressure drift chamber using cosmic rays is described. Two multiwire proportional chambers, mounted above and below the detector, are used to define the track of the cosmic particle in the drift chamber. The drift chamber is read out by FADCs (Flash Analog to Digital Converter), and the drift time is determined from the FADC signals by the DOS- (Difference Of Samples) method. The measured drift time versus drift distance relation showed good agreement with the relation, which is expected from the spatial dependence of the electric field and the dependence of the drift velocity on this field. (orig.) [de

  17. Feasibility studies of high-pressureproportional counter for absolute activity measurement

    International Nuclear Information System (INIS)

    Hino, Y.; Kawada, Y.

    1988-01-01

    A high-pressure proportional counter system is constructed. The high pressure 4πβ counter system constructed is made of aluminum and is divided into two 2π counters. The gas pressure is controlled with a pressure regulator and very fine leak valves to keep the balance of a stable pressure and constant flow rate. Investigation of characteristics of th counter shows that there is an almost linear relation between voltage and pressure. The linearlity of gas gain of this counter to the electron energies is measured with different gas pressures. Quite good linear gas multiplication is obtained at 0.9 MPa. Another investigation is made of application of to activity measurement of 109 Cd. When the gas pressure is over 0.5 MPa, the proportion of collected conversion electrons to absolute activity comes to a constant value of 96 %. This is quite good agreement with the decay data of 96.4 % conversion electron emission rate. The study indicated many excellent features for activity measurement. Especially the efficiency variation technique is good for automatic data acquisition with a programmable high voltage supplier. Moreover, since it is possible to obtain absolute activity with only one sample, it will be quite useful for limited samples experiments. (N.K.)

  18. Multiwire proportional chambers in the devices for molecular biology constructed at JINR

    Energy Technology Data Exchange (ETDEWEB)

    Anisimov, Y S; Chernenko, S P; Ivanov, A B; Peshekhonov, V D; Skvaril, J; Zanevsky, Y V [Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of High Energy; Kheiker, D M [Joint Inst. for Nuclear Research, Dubna (USSR). Lab. of High Energy; AN SSSR, Moscow. Inst. Kristallografii)

    1980-10-01

    The automation of measuring processes in molecular biology is a current problem. In order to solve this problem, conventionally used methods should be changed for an up-to-date technique which allows the processes of data measurement and analysis to be automated. Toward this end two-coordinate proportional chambers (MWPCs) are coming widely into use. The use of MWPCs in devices for radiochromatography and x-ray diffractrometry is discussed in this paper. A new device consisting of proportional chambers has been constructed for an automated analysis of thin layer radiochromatograms. The device enables one to localize radioactive zones (labelled with /sup 3/H, /sup 14/C, /sup 32/P), to identify radionuclides and to measure their activities. The device has a high sensitivity (5 pCi for tritium), a small dead time, good space resolution (in the case of /sup 3/H zones spaced 1-2 mm apart are separated) and high reproducibility. For x-ray diffractometry of single crystals, a high counting rate device has been constructed on the basis of a MWPC with a total number of channels amounting to 350 x 200 = 70,000. The dead time of the device is about 0.6 ..mu..s which allows to detect 3 x 10/sup 5/ events/s at counting losses of no more than 20%. The quantum efficiency (Cu K..cap alpha..) is about 73%. The X and Y space resolution (fwhm) is equal to 1 mm and 1.7 mm, respectively.

  19. Development of multiwire gas detectors for X-rays

    International Nuclear Information System (INIS)

    Sales, Eraldo de

    2015-01-01

    This work presents the prototype of a 2D position sensitive gas detector for application in X-ray scattering and diffraction experiments. Starting from a detector initially developed for other applications and will show the required changes on the original concept of this device. The strategy used to determine the necessary adaptations were based on searching in the literature for the overall characteristics of a multi-wire X-ray detector (choice of gas, pressure, window, etc.), the use of simulations, implementation of the changes and finally operational tests. Computational tools were used to calculate the mechanical strength and attenuation of the X-ray photons that helped to determine the most appropriate material for the construction of the entrance window. Detector simulations were built with Garfield software and were used to study the overall properties of the detector, and to determine the optimum parameters for the equipment operation. Typical parameters are the distance between the wires, wire diameter, high voltage to be used, among several other parameters. The results obtained showed that the multi-wire detector concept with the implemented adaptations allowed the detection of X-rays. However, depending on the application, it may be necessary improve the resolution of the equipment, in order to have a better description of the collected data. Several ideas are suggested for this improvement. It is also presented interesting results obtained with a microscopic pattern detector called triple GEM. This device belongs to the Gas Detectors Development group (GDD group) at CERN and was used in my training at this institution. The results showed the potential of the equipment for detection of X-rays. The results and simulations presented in this work, confirmed that the changes in the concept of the original detector permitted it use on X-ray detection applications. Also, it was possible to obtain several indications for further optimization, which may

  20. Low Blood Pressure

    Science.gov (United States)

    ... a problem. Sometimes blood pressure that is too low can also cause problems. Blood pressure is the ... reading is 90/60 or lower, you have low blood pressure. Some people have low blood pressure ...

  1. Multiaxial low cycle fatigue life under non-proportional loading

    International Nuclear Information System (INIS)

    Itoh, Takamoto; Sakane, Masao; Ohsuga, Kazuki

    2013-01-01

    A simple and clear method of evaluating stress and strain ranges under non-proportional multiaxial loading where principal directions of stress and strain are changed during a cycle is needed for assessing multiaxial fatigue. This paper proposes a simple method of determining the principal stress and strain ranges and the severity of non-proportional loading with defining the rotation angles of the maximum principal stress and strain in a three dimensional stress and strain space. This study also discusses properties of multiaxial low cycle fatigue lives for various materials fatigued under non-proportional loadings and shows an applicability of a parameter proposed by author for multiaxial low cycle fatigue life evaluation

  2. New proportional counter for in vivo detection of traces of plutonium in the lungs; Nouveau compteur proportionnel destine a la detection in vivo de traces de plutonium dans les poumons

    Energy Technology Data Exchange (ETDEWEB)

    Morucci, J [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    Development of a multi-wire proportional counter having a uniform response over 250 cm{sup 2} thanks to corrections made for boundary effects, and having a low background per sq. cm. due to the use of two identical counters set in anti-coincidence in the same enclosure is described. (author) [French] Etude et mise au point d'un compteur proportionnel multifils de reponse utile homogene sur une surface de 250 cm{sup 2} grace a la correction des effets de bords et de faible mouvement propre par cm{sup 2} grace a deux compteurs identiques montes en anticoincidence dans la meme enceinte. (auteur)

  3. A multiwire secondary emission profile monitor for small emittance beams

    International Nuclear Information System (INIS)

    Chehab, R.; Bonnard, J.; Humbert, G.; Leblond, B.; Saury, J.L.

    1985-01-01

    A secondary emission monitor using two multiwire grids separated by a positively biased collector has been constructed and tested with a 1 GeV electron beam at the Orsay Linac. The monitor installed just before the electron-positron converter has 8 gold-plated-tungsten wires of 0.1 mm diameter equally spaced 0.2 mm apart in each plane. Each wire is connected with an integrator using a low-bias current operational amplifier. The wire planes and the collector are moved into the beam by a stepping motor : that allows beam-position verification. We measured narrow profiles for 1 Amp peak current pulses of 30 nanoseconds width. Profiles are displayed on a scope and allow emittance determination by the three gradient method. Such a monitor is very useful to control the electron beam position and dimensions on the converter, because the positron source dimensions are rather bigger than those of the incident beam and the geometrical acceptance of the positron Linac is limited

  4. Multiwire proportional chamber with a supporting line on anode wires

    International Nuclear Information System (INIS)

    Viktorov, V.A.; Golovkin, S.V.

    1980-01-01

    Results are presented of experimental investigations on a supporting line (wire) used in large-sized proportional chambers to compensate for electrostatic forces. The length of anode wires (gilded tungsten of 0.02 mm in diameter) in the chamber constituted 600 mm, the pitch 2 mm, the total number of channels 192. High-voltage electrodes are made of Cu-Be wire of 0.1 mm in diameter, the pitch is 2 mm. The gap between anode and cathode plates is 6 mm. The supporting line is an enamelled nichrome wire of 0.2 mm in diameter enclosed in an additional fluoroplastic insulation. The outside diameter was equal to 0.4 mm. The supporting line was placed through the centre of the chamber at right angles and immediately adjacent to anode wires with the tension of 2000 g. A negative compensating potential was applied to it. The controllable parameter was the chamber efficiency at variable paAameters: (1) an operating voltage in the chamber; (2) Vsub(c) - a compensating potential of the supporting line, and (3) a beam axis relative coordinate. The performed investigations showed that the supporting line of this type is simple and reliable in operation (electric breakdown occurs at Vsub(c) > 3.5 kV). The noneffective zone in the supporting region can be reduced to approximately 2.4 mm which constitutes approximately 0.3% of the chamber total sensitive region

  5. Simultaneous acquisition of X-ray spectra using a multi-wire, position-sensitive gas flow detector

    International Nuclear Information System (INIS)

    Beaven, Peter A.; Marmotti, Mauro; Kampmann, Reinhard; Knoth, Joachim; Schwenke, Heinrich

    2003-01-01

    A multi-wire, gas-filled position-sensitive detector has been developed for the simultaneous recording of wavelength-dispersed X-ray signals that enables X-ray fluorescence spectrometry with a limited multi-element capability in the low Z element range. Details of the modular construction of the detector are given. The detector performance was characterized using Al-Kα radiation and a variable slit system. The detector has been applied in a laboratory spectrometer equipped with an electron source and a double multilayer mirror device as the wavelength-dispersing element. Spectra from Al and Si obtained in the simultaneous acquisition mode show good agreement with calculations performed using a ray-tracing model

  6. Pressure control of hydraulic servo system using proportional control valve

    International Nuclear Information System (INIS)

    Yang, Kyong Uk; Oh, In Ho; Lee, Ill Yeong

    1999-01-01

    The purpose of this study is to develop a control scheme for the hydraulic servo system which can rapidly control the pressure in a hydraulic cylinder with very short stroke. Compared with the negligible stroke of the cylinder in the system, the flow gain of the proportional pressure control valve constituting the hydraulic servo system is relatively large and the time delay on the response of the valve is quite long. Therefore, the pressure control system, in this study tends to get unstable during operations. Considering the above mentioned characteristics of the system, a two-degree-of-freedom control scheme, composed of the I-PDD 2 ... feedback compensator and the feedforward controller, is proposed. The reference model scheme is used in deciding the parameters of the controllers. The validity of the proposed control scheme is confirmed through the experiments

  7. Thermal poling of multi-wire array optical fiber

    DEFF Research Database (Denmark)

    Huang, Lin; An, Honglin; Hayashi, Juliano G.

    2018-01-01

    We demonstrate in this paper thermal poling of multi-wire array fibers, which extends poling of fibers with two anodes to similar to 50 and similar to 500 wire array anodes. The second harmonic microscopy observations show that second order nonlinearity (SON) layers are developed surrounding all...... the rings of wires in the similar to 50 anode array fiber with poling of 1.8kV, 250 degrees C and 30min duration, and the outer rings of the similar to 500 anode array fiber at lower poling temperature. Our simulations based on a two-dimensional charge dynamics model confirm this can be explained...

  8. A high-resolution multiwire area detector for X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Faruqi, A R; Andrews, H [Medical Research Council, Cambridge (UK). Lab. of Molecular Biology

    1989-11-10

    A high-resolution multiwire area detector has been developed for recording X-ray scattering from biological specimens. The detector is 100x100 mm{sup 2} and, under the present operating conditions, has a spatial resolution of about 250 {mu}m in both directions. The detector is set up on a double-mirror focusing camera on a rotating anode X-ray generator and has been used in a number of small-angle experiments, two of which are described in this paper. (orig.).

  9. Low Blood Pressure (Hypotension)

    Science.gov (United States)

    ... lowest at night and rises sharply on waking. Blood pressure: How low can you go? What's considered low ... low blood pressure. Medications that can cause low blood pressure Some medications can cause low blood pressure, including: ...

  10. Quantitation of images from a multiwire camera for autoradiography of tritium-labelled substances

    International Nuclear Information System (INIS)

    Lockett, S.J.; Ramsden, D.B.; Bradwell, A.R.

    1987-01-01

    It has been shown that tritium-labelled substances in two-dimensional systems can be quantitated using a multiwire camera. Its accuracy has now been improved by correcting results for non-uniformity of response over the detection area. Uniformity was assessed by imaging plates of nominally uniform activity. The results were then used to correct images from plates containing tritium-labelled proteins using a computer program. Errors were reduced from 11.3 (+ -6.1) to 7.7 (+ - 2.8)% for standard sources and from 6.2 (+ - 1.8) to 1.9 (+ -0.6)% for a plate containing the labelled proteins. The conducting carbon layer covering the plate absorbed 36 (+ - 3)% of the tritium beta radiation and was estimated to be 85 nm in thickness. Quantitation of the labelled proteins by the camera gave a good correlation with protein content (chi-squared: 30-40%). The activities of the protein samples were measured to an accuracy of 10% by comparison with standard sources. These results indicate useful quantitation of tritiated compounds in two-dimensional media using the multiwire camera. (author)

  11. Gas proportional detectors with interpolating cathode pad readout for high track multiplicities

    International Nuclear Information System (INIS)

    Yu, Bo.

    1991-12-01

    New techniques for position encoding in very high rate particle and photon detectors will be required in experiments planned for future particle accelerators such as the Superconducting Super Collider and new, high intensity, synchrotron sources. Studies of two interpolating cathode ''pad'' readout systems are described in this thesis. They are well suited for high multiplicity, two dimensional unambiguous position sensitive detection of minimum ionizing particles and heavy ions as well as detection of x-rays at high counting rates. One of the readout systems uses subdivided rows of pads interconnected by resistive strips as the cathode of a multiwire proportional chamber (MWPC). A position resolution of less than 100 μm rms, for 5.4 keV x-rays, and differential non-linearity of 12% have been achieved. Low mass (∼0.6% of a radiation length) detector construction techniques have been developed. The second readout system uses rows of chevron shaped cathode pads to perform geometrical charge division. Position resolution (FWHM) of about 1% of the readout spacing and differential non-linearity of 10% for 5.4 keV x-rays have been achieved. A review of other interpolating methods is included. Low mass cathode construction techniques are described. In conclusion, applications and future developments are discussed. 54 refs

  12. Calibration of an ultra-low-background proportional counter for measuring 37Ar

    International Nuclear Information System (INIS)

    Seifert, A.; Aalseth, C. E.; Bonicalzi, R. M.; Bowyer, T. W.; Day, A. R.; Fuller, E. S.; Haas, D. A.; Hayes, J. C.; Hoppe, E. W.; Humble, P. H.; Keillor, M. E.; LaFerriere, B. D.; Mace, E. K.; McIntyre, J. I.; Merriman, J. H.; Miley, H. S.; Myers, A. W.; Orrell, J. L.; Overman, C. T.; Panisko, M. E.

    2013-01-01

    An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with 14 C/ 3 H, age-dating of groundwater with 39 Ar, and soil-gas assay for 37 Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of 37 Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of 37 Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for 37 Ar soil gas background studies

  13. Flow proportional sampling of low level liquid effluent

    International Nuclear Information System (INIS)

    Colley, D.; Jenkins, R.

    1989-01-01

    A flow proportional sampler for use on low level radioactive liquid effluent has been developed for installation on all CEGB nuclear power stations. The sampler, operates by drawing effluent continuously from the main effluent pipeline, through a sampler loop and returning it to the pipeline. The effluent in this loop is sampled by taking small, frequent aliquots using a linear acting shuttle valve. The frequency of operation of this valve is controlled by a flowmeter installed in the effluent line; sampling rate being directly proportional to effluent flowrate. (author)

  14. CMIS arithmetic and multiwire news for QCD on the connection machine

    International Nuclear Information System (INIS)

    Brickner, R.G.

    1991-01-01

    Our collaboration has been running Wilson fermion QCD simulations on various Connection Machines for over a year and a half. During this time, we have continually optimized our code for operations found in the fermion matrix inversion. Our current version of the matrix inversion is written almost entirely in CMIS (Connection Machine Instruction Set), and utilizes both high-speed arithmetic and multiwire 'news' (nearest-neighbor communications). We present details of how these and other features of our code are implemented on the CM-2. (orig.)

  15. Time characteristics of a multi-wire 4πβ-counter

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Watanabe, Tamaki

    1981-01-01

    In order to examine the time characteristics of a multi-wire 4πβ-counter for the 4πβ-γ coincidence system, measurement was made on the time distributions of the pulses from the individual anodes. The time distribution obtained by each anode was explained mainly by the distribution of primary ionizing position. A similar time distribution was obtained in the case that the alternating wires cathodes, when the individual anodes had the same effective detection region. Spurious pulses were observed in 90% argon plus 10% methane mixture at the end voltage of the plateau region and not methane gas. (author)

  16. Photon and neutron dose discrimination using low pressure proportional counters with graphite and A150 walls

    International Nuclear Information System (INIS)

    Kylloenen, J.; Lindborg, L.

    2005-01-01

    Full text: The determination of both the low- and high-LET components of ambient dose equivalent in mixed fields is possible with microdosimetric methods. With the multiple-event microdosimetric variance covariance method the sum of those components are directly obtained also in pulsed beams. However, if the value of each dose component is needed a more extended analysis is required. The use of a graphite walled proportional detector in combination with a tissue-equivalent proportional counter in combination with the variance covariance method was here investigated. MCNP simulations were carried out for relevant energies to investigate the photon and neutron responses of the two detectors. The combined graphite and TEPC system, the Sievert instrument, was used for measurements at IRSN, Cadarache, in the workplace calibration fields of CANEL+, SIGMA, a Cf-252 and a moderated Cf(D 2 O,Cd) radiation field. The response of the instrument in various monoenergetic neutron fields is also known from measurements at PTB. The instrument took part in the measurement campaigns in workplace fields in the nuclear industry organized within the EVIDOS contract. The results are analyzed and the method of using a graphite detector compared with alternative methods of analysis is discussed. (author)

  17. Energy–pressure relation for low-dimensional gases

    Directory of Open Access Journals (Sweden)

    Francesco Mancarella

    2014-10-01

    Full Text Available A particularly simple relation of proportionality between internal energy and pressure holds for scale-invariant thermodynamic systems (with Hamiltonians homogeneous functions of the coordinates, including classical and quantum – Bose and Fermi – ideal gases. One can quantify the deviation from such a relation by introducing the internal energy shift as the difference between the internal energy of the system and the corresponding value for scale-invariant (including ideal gases. After discussing some general thermodynamic properties associated with the scale-invariance, we provide criteria for which the internal energy shift density of an imperfect (classical or quantum gas is a bounded function of temperature. We then study the internal energy shift and deviations from the energy–pressure proportionality in low-dimensional models of gases interpolating between the ideal Bose and the ideal Fermi gases, focusing on the Lieb–Liniger model in 1d and on the anyonic gas in 2d. In 1d the internal energy shift is determined from the thermodynamic Bethe ansatz integral equations and an explicit relation for it is given at high temperature. Our results show that the internal energy shift is positive, it vanishes in the two limits of zero and infinite coupling (respectively the ideal Bose and the Tonks–Girardeau gas and it has a maximum at a finite, temperature-depending, value of the coupling. Remarkably, at fixed coupling the energy shift density saturates to a finite value for infinite temperature. In 2d we consider systems of Abelian anyons and non-Abelian Chern–Simons particles: as it can be seen also directly from a study of the virial coefficients, in the usually considered hard-core limit the internal energy shift vanishes and the energy is just proportional to the pressure, with the proportionality constant being simply the area of the system. Soft-core boundary conditions at coincident points for the two-body wavefunction introduce

  18. Energy–pressure relation for low-dimensional gases

    International Nuclear Information System (INIS)

    Mancarella, Francesco; Mussardo, Giuseppe; Trombettoni, Andrea

    2014-01-01

    A particularly simple relation of proportionality between internal energy and pressure holds for scale-invariant thermodynamic systems (with Hamiltonians homogeneous functions of the coordinates), including classical and quantum – Bose and Fermi – ideal gases. One can quantify the deviation from such a relation by introducing the internal energy shift as the difference between the internal energy of the system and the corresponding value for scale-invariant (including ideal) gases. After discussing some general thermodynamic properties associated with the scale-invariance, we provide criteria for which the internal energy shift density of an imperfect (classical or quantum) gas is a bounded function of temperature. We then study the internal energy shift and deviations from the energy–pressure proportionality in low-dimensional models of gases interpolating between the ideal Bose and the ideal Fermi gases, focusing on the Lieb–Liniger model in 1d and on the anyonic gas in 2d. In 1d the internal energy shift is determined from the thermodynamic Bethe ansatz integral equations and an explicit relation for it is given at high temperature. Our results show that the internal energy shift is positive, it vanishes in the two limits of zero and infinite coupling (respectively the ideal Bose and the Tonks–Girardeau gas) and it has a maximum at a finite, temperature-depending, value of the coupling. Remarkably, at fixed coupling the energy shift density saturates to a finite value for infinite temperature. In 2d we consider systems of Abelian anyons and non-Abelian Chern–Simons particles: as it can be seen also directly from a study of the virial coefficients, in the usually considered hard-core limit the internal energy shift vanishes and the energy is just proportional to the pressure, with the proportionality constant being simply the area of the system. Soft-core boundary conditions at coincident points for the two-body wavefunction introduce a length scale

  19. Construction and performance of MEGAs low-mass, high-rate cylindrical MWPCs

    Science.gov (United States)

    Cooper, M. D.; Armijo, V.; Black, J. K.; Bolton, R. D.; Carius, S.; Espinoza, C.; Hart, G.; Hogan, G. E.; Gonzales, A.; Kroupa, M. A.; Mischke, R. E.; Sandoval, J.; Schilling, S.; Sena, J.; Suazo, G.; Whitehouse, D. A.; Wilkinson, C. A.; Stantz, K.; Szymanski, J. J.; Jui, C. C.; Gagliardi, C. A.; Tribble, R. E.; Tu, X.-L.; Fisk, R. J.; Koetke, D. D.; Manweiler, R. W.; Nord, P. M.; Stanislaus, S.; Piilonen, L. E.; Zhang, Y. D.

    A design for extremely low mass, high-resolution multiwire proportional chambers (MWPC) was achieved by the MEGA collaboration in its experiment to search for the lepton family number violating decay μ→eγ. To extend the present branching ratio limit by over an order of magnitude, these MWPCs were operated in high particle fluxes. They showed minimal effects of aging, and evidenced spatial and energy resolutions for the orbiting positrons from muon decay which were consistent with our design parameters. The unique features of these chambers, their assembly into the MEGA positron spectrometer, and their performance during the experiment are described in this paper.

  20. A study on the improvement of the load pressure feedback mechanism of the proportional pressure control valve

    International Nuclear Information System (INIS)

    Oh, In Ho; Jang, Ji Seong; Lee, Ill Yeong; Chung, Dai Jong; Cho, Sung Hyun

    1999-01-01

    The proportional pressure control valve having versatile functions and higher performance is an essential component in the open loop controlled rear wheel steering gear of the four wheel steering system on a passenger car. In this study, the authors suggest a new type of load pressure feedback mechanism which can make it easy change the control range of load pressure without changing the capacity of solenoid. The concept of the suggested mechanism, composed of the pressure chamber with throttles in series, was described. The mathematical model was derived from the rear wheel steering gear system consisting of a valve and a cylinder for the purpose of analyzing the valve characteristics. And the programme for computing the characteristic of the valve was developed. Experiments were carried out to confirm the performance of the valve and computations were performed to ascertain the usefulness of the developed programme. The results from the computations fairly coincide with those from the experiments. The results from the experiments and computations show that the performance of new valve is as good as that of the already developed one and the new valve has an advantage in the easiness in varying the control range of load pressure

  1. Low-pressure

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Richard [Membrane Technology And Research, Inc., Newark, CA (United States); Kniep, Jay [Membrane Technology And Research, Inc., Newark, CA (United States); Hao, Pingjiao [Membrane Technology And Research, Inc., Newark, CA (United States); Chan, Chi Cheng [Membrane Technology And Research, Inc., Newark, CA (United States); Nguyen, Vincent [Membrane Technology And Research, Inc., Newark, CA (United States); Huang, Ivy [Membrane Technology And Research, Inc., Newark, CA (United States); Amo, Karl [Membrane Technology And Research, Inc., Newark, CA (United States); Freeman, Brice [Membrane Technology And Research, Inc., Newark, CA (United States); Fulton, Don [Membrane Technology And Research, Inc., Newark, CA (United States); Ly, Jennifer [Membrane Technology And Research, Inc., Newark, CA (United States); Lipscomb, Glenn [Membrane Technology And Research, Inc., Newark, CA (United States); Lou, Yuecun [Membrane Technology And Research, Inc., Newark, CA (United States); Gogar, Ravikumar [Membrane Technology And Research, Inc., Newark, CA (United States)

    2015-01-29

    This final technical progress report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the Department of Energy (DOE NETL) on development of low-pressure membrane contactors for carbon dioxide (CO2) capture from power plant flue gas (award number DE-FE0007553). The work was conducted from October 1, 2011 through September 30, 2014. The overall goal of this three-year project was to build and operate a prototype 500 m2 low-pressure sweep membrane module specifically designed to separate CO2 from coal-fired power plant flue gas. MTR was assisted in this project by a research group at the University of Toledo, which contributed to the computational fluid dynamics (CFD) analysis of module design and process simulation. This report details the work conducted to develop a new type of membrane contactor specifically designed for the high-gas-flow, low-pressure, countercurrent sweep operation required for affordable membrane-based CO2 capture at coal power plants. Work for this project included module development and testing, design and assembly of a large membrane module test unit at MTR, CFD comparative analysis of cross-flow, countercurrent, and novel partial-countercurrent sweep membrane module designs, CFD analysis of membrane spacers, design and fabrication of a 500 m2 membrane module skid for field tests, a detailed performance and cost analysis of the MTR CO2 capture process with low-pressure sweep modules, and a process design analysis of a membrane-hybrid separation process for CO2 removal from coal-fired flue gas. Key results for each major task are discussed in the report.

  2. Proportional gas scintillation detectors and their applications

    International Nuclear Information System (INIS)

    Petr, I.

    1978-01-01

    The principle is described of a gas proportional scintillation detector and its function. Dependence of Si(Li) and xenon proportional detectors energy resolution on the input window size is given. A typical design is shown of a xenon detector used for X-ray spetrometry at an energy of 277 eV to 5.898 keV and at a gas pressure of 98 to 270 kPa. Gas proportional scintillation detectors show considerable better energy resolution than common proportional counters and even better resolution than semiconductor Si(Li) detectors for low X radiation energies. For detection areas smaller than 25 mm 2 Si(Li) detectors show better resolution, especially for higher X radiation energies. For window areas 25 to 190 mm 2 both types of detectors are equal, for a window area exceeding 190 mm 2 the proportional scintillation detector has higher energy resolution. (B.S.)

  3. Space-charge effects of the proportional counters in a multiple-ionization chamber

    International Nuclear Information System (INIS)

    Mang, M.

    1993-01-01

    At the ALADIN spectrometer of the GSI in october 1991 for the first time the new multiple ionization chamber was applied, in the two anode planes of which are additional multiwire-proportional counters. The proportional counters are required in order to make the detection of light fragments (Z 4 gold projectiles per second by these positive space charges the homogeneous electric field of the MUSIC is disturbed. This effect is especially strong in the beam plane. As consequence of the space charge additionally electrons are focused on the proportional counter so that their amplitudes in dependence on the beam intensity increase up to the 2.5-fold. Furthermore the y coordinate is falsified, because the electrons are diverted to the medium plane. On the measurement of the x coordinate this diversion has with maximally 0.1% only a small influence. These space-charge effects can be qualitatively described by a schematic model, which assumes a stationary positive space charge. Additionally for the proportional counters, which are not in the beam plane, their resolution was determined. In these counters the space-charge effects are small, because essentially fewer particles are registrated than in the medium MWPC's. By this charges of fragments with Z<10 could be separated. The charge resolution amounted at lithium 0.8 charge units. The position resolution of the proportional counters in y direction was determined to less than 8 mm. The detection probability of the fragments amounts for lithium 90% and from boron all fragments are detected

  4. Point and track-finding processors for multiwire chambers

    CERN Document Server

    Hansroul, M

    1973-01-01

    The hardware processors described below are designed to be used in conjunction with multi-wire chambers. They have the characteristic of being based on computational methods in contrast to analogue procedures. In a sense, they are hardware implementations of computer programs. But, being specially designed for their purpose, they are free of the restrictions imposed by the architecture of the computer on which the equivalent program is to run. The parallelism inherent in the algorithms can thus be fully exploited. Combined with the use of fast access scratch-pad memories and the non-sequential nature of the control program, the parallelism accounts for the fact that these processors are expected to execute 2-3 orders of magnitude faster than the equivalent Fortran programs on a CDC 7600 or 6600. As a consequence, methods which are simple and straightforward, but which are impractical because they require an exorbitant amount of computer time can on the contrary be very attractive for hardware implementation. ...

  5. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  6. A multiwire ionization chamber readout circuit using current mirrors

    International Nuclear Information System (INIS)

    Rawnsley, W.R.; Smith, D.; Moskven, T.

    1997-01-01

    A circuit which utilizes current mirrors has been used to apply high voltage bias to the wires of a multiwire ionization chamber (MWIC) profile monitor while still allowing measurement of the beam-induced ion-electron currents collected on the wires. Bias voltages of up to 250 V have been used while wire currents over a range of 0.5 nA to 50 nA have been measured. The circuit is unipolar but can be designed for positive or negative bias. The mirrors also provide a current gain of 10, reducing the effects of transistor leakage and extending the useful range of the circuit to lower signal levels. A module containing 32 Wilson current mirrors has been constructed and is used with a MWIC monitor in TRIUMF close-quote s Parity experiment beamline. copyright 1997 American Institute of Physics

  7. Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting.

    Science.gov (United States)

    Mace, Emily; Aalseth, Craig; Alexander, Tom; Back, Henning; Day, Anthony; Hoppe, Eric; Keillor, Martin; Moran, Jim; Overman, Cory; Panisko, Mark; Seifert, Allen

    2017-08-01

    Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the beta decay spectra. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120mg of H 2 O and present sensitivity results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Two-dimension multiwire detector for ionizing radiation; Detector multifilar bidimensional para radiacao ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Barberino, Carlos Henrique

    1994-12-31

    A multiwire proportional Counter of 100 x 100 mm{sup 2} sensitive area has been developed. The chamber is formed by three planes: a cathode plane of 50 {mu}m gold coated tungsten wires stretched on an Epoxi frame; and anode plane made of 20 {mu}m gold plated tungsten wires stretched at 45 deg C with respect to the first cathode wires; and second cathode plane made of copper strips on a printed circuit board at 90 deg C with respect to the first cathode. The cathode strips are connected to the taps of delay-lines chips. The position of the incidence of radiation is extracted by measuring the time difference of the pulse arriving at the extremities of the delay-line chain for each coordinate. The performance of the detector has been tested using 5.89 KeV X-rays from a {sup 55} Fe source, and 8.04 KeV from Rigaku X-rays generator, operating the detector with 90% Ar + 10% CH{sub 4} gas mixture at 930 mbar. An energy resolution of 26% was obtained. An integral non linearity better than 0.3% and a position resolution better than 1 mm have been observed. The information corresponding to each one of the coordinates were digitized by a TDC in a CAMAC system and stored event by event in a micro-computer (IBM-AT). (author) 56 refs., 68 figs.

  9. Two-dimension multiwire detector for ionizing radiation; Detector multifilar bidimensional para radiacao ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Barberino, Carlos Henrique

    1993-12-31

    A multiwire proportional Counter of 100 x 100 mm{sup 2} sensitive area has been developed. The chamber is formed by three planes: a cathode plane of 50 {mu}m gold coated tungsten wires stretched on an Epoxi frame; and anode plane made of 20 {mu}m gold plated tungsten wires stretched at 45 deg C with respect to the first cathode wires; and second cathode plane made of copper strips on a printed circuit board at 90 deg C with respect to the first cathode. The cathode strips are connected to the taps of delay-lines chips. The position of the incidence of radiation is extracted by measuring the time difference of the pulse arriving at the extremities of the delay-line chain for each coordinate. The performance of the detector has been tested using 5.89 KeV X-rays from a {sup 55} Fe source, and 8.04 KeV from Rigaku X-rays generator, operating the detector with 90% Ar + 10% CH{sub 4} gas mixture at 930 mbar. An energy resolution of 26% was obtained. An integral non linearity better than 0.3% and a position resolution better than 1 mm have been observed. The information corresponding to each one of the coordinates were digitized by a TDC in a CAMAC system and stored event by event in a micro-computer (IBM-AT). (author) 56 refs., 68 figs.

  10. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  11. 39Ar/Ar measurements using ultra-low background proportional counters

    International Nuclear Information System (INIS)

    Hall, Jeter; Aalseth, Craig E.; Bonicalzi, Ricco M.; Brandenberger, Jill M.; Day, Anthony R.; Humble, Paul H.; Mace, Emily K.; Panisko, Mark E.; Seifert, Allen

    2016-01-01

    Age-dating groundwater and seawater using the 39 Ar/Ar ratio is an important tool to understand water mass-flow rates and mean residence time. Low-background proportional counters developed at Pacific Northwest National Laboratory use mixtures of argon and methane as counting gas. We demonstrate sensitivity to 39 Ar by comparing geological (ancient) argon recovered from a carbon dioxide gas well and commercial argon. The demonstrated sensitivity to the 39 Ar/Ar ratio is sufficient to date water masses as old as 1000 years. - Highlights: • 39 Ar/Ar age dating is important for understanding environmental water migration. • Ultra low background proportional counters have been developed. • 39 Ar is detected in atmospheric argon at a rate of 70.3 counts per day. The demonstrated background is 166 counts per day. • Age dating is possible for water with underground residence time of up to 1000 years.

  12. Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Emily; Aalseth, Craig; Alexander, Tom; Back, Henning; Day, Anthony; Hoppe, Eric; Keillor, Martin; Moran, Jim; Overman, Cory; Panisko, Mark; Seifert, Allen

    2017-08-01

    Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the isotope’s respective energy spectra. This activity makes direct dual-isotope measurements challenging without additional chemistry to concentrate the tritium in a sample. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120 mg of H2O and present sensitivity results.

  13. Digital radiographic scanning installation with multiwire proportional chamber

    International Nuclear Information System (INIS)

    Babichev, E.A.; Baru, S.E.; Khabakhpashev, A.G.; Kolachev, G.M.; Savinov, G.A.; Shekhtman, L.I.; Sidorov, V.A.; Volobuev, A.I.

    1991-01-01

    A digital radiographic installation for medical diagnostics is described. Distribution of X-ray intensity in horizontal direction is measured by a one-coordinate MWPC with a 1.2 mm channel. A two-dimensional image is produced by mechanical scanning with 1 mm channel width in vertical direction. The number of pixels in the image is 320x256. The MWPC works in count mode with quantum efficiency 25% (50 keV) and count rate capability 600 kHz/channel. Results of testing a prototype with 64 channels 0.6 mm width are also presented. (orig.)

  14. Construction of self-supporting cylindrical multiwire proportional chambers

    International Nuclear Information System (INIS)

    Kobayashi, Masaaki; Fujitani, Takeo; Omori, Tsunehiko; Sugimoto, Shojiro; Yamaguchi, Yoshitake; Nakagawa, Yuji; Wada, Toshiaki.

    1984-08-01

    Cylindrical MWPC's have been constructed with 240-430 mm in anode diameter and 750 mm in length. They are supported by inner and outer cathode cylinders made of approximately 6 mm thick aramid fibre/phenolic resin honeycomb, sandwiched between 50 μm thick Kapton sheets with or without Cu strips laminated to them. The chambers have been successfully used throughout the E68(P-barPC) experiment at the KEK 12 GeV Proton Synchrotrons. Constructional details are described. (author)

  15. Computer aided production of manufacturing CAMAC-wired boards by the multiwire-technique

    Energy Technology Data Exchange (ETDEWEB)

    Martini, M; Brehmer, W

    1975-10-01

    The multiwire-technique is a computer controlled wiring method for the manufacturing of circuit boards with insulated conductors. The technical data for production are dimensional drawings of the board and a list of all points which are to be connected. The listing must be in absolute co-ordinates including a list of all soldering points for component parts and a reproducible print pattern for inscription. For this wiring method a CAMAC standard board, a layout plan with alpha-numeric symbols, and a computer program which produces the essential technical data were developed. A description of the alpha-numeric symbols, the quality of the program, recognition and checking of these symbols, and the produced technical data is presented. (auth)

  16. The great advance in the technology of particle detectors during the year was the discovery of the properties of multiwire proportional chambers and drift chambers

    CERN Multimedia

    CERN PhotoLab

    1968-01-01

    In these chambers each wire is an independent proportional counter with its own amplifier and logic circuit. The low cost of the associated electronics makes realistic moderately large systems, with thousands of wires. The resolution time of each wire is of the order of 100 ns, with 3mm spacing. Roger Bouclier is working on an early model tested in a PS beam-line.

  17. Children with low birth weight and low gestational age in Oslo, Norway: immigration is not the cause of increasing proportions.

    OpenAIRE

    Stoltenberg, C; Magnus, P

    1995-01-01

    STUDY OBJECTIVE--To determine the influence of children born to immigrant mothers on the total proportions of low birth weight and preterm deliveries in Oslo and to explain the increases in the proportions of children with low birth weight and low gestational age since 1980-1982. DESIGN--This was a cross sectional study based on Norwegian Medical Birth Registry data and information on mothers' country of birth from the Central Bureau of Statistics. SETTING--Oslo, Norway 1968-91. POPULATION--A...

  18. A two-dimensional detector with delay line readout for slow neutron fields measurements

    International Nuclear Information System (INIS)

    Cheremukhina, G.A.; Chernenko, S.P.; Ivanov, A.B.

    1992-01-01

    This article presents the description of a two-dimensional detector of slow neutrons together with its readout and data acquisition electronics based on a PC/AT> The detector with a sensitive area of 260x140 mm 2 is based on a high pressure multiwire proportional chamber with delay line readout and gas filling of 3.0 atm. 3 He + propane. 25 refs.; 10 figs.; 2 tabs

  19. Search of 2K(2ν) capture in 78 Kr and 124 Xe by means of wall-less proportional counters

    International Nuclear Information System (INIS)

    Volchenko, G.V.; Gavrilyuk, Yu.M.; Kuz'minov, V.V.; Osetrova, N.Ya.; Ratkevich, S.S.

    1998-01-01

    The technique of the experiment on the double two-neutrino K-capture search in isotopes of rare gases 78 Kr and 124 Xe is described. Multiwire wall-less proportional counters of a large volume are used in this experiment. Methods of decreasing the counter background noise in the energy range 10-100 keV are considered. These methods are based on the discrimination of events on the coordinate along the anode filament and the pulse rise time. The sensitivity of the experimental installation is estimated according to the half-life 78 Kr (1.2 x 10 21 years) and 124 Xe (2.6 x 10 20 years) with respect to the 2K(2ν) capture (68% certain level)

  20. Gaseous Multiplication factor measurements on low pressure ethylene

    International Nuclear Information System (INIS)

    Hevia Vives, Alberto

    2008-01-01

    The present investigation consists of a study of a Proportional Counter considered as a fundamental part of an Absolute Neutron Dosimeter developed for the Chilean Nuclear Energy Commission. The proportional counter consists of a Polyethylene Cathode of approximately 5 cm in diameter and an Anode consisting of a central wire of 5 μm in diameter. The proportional counter is biased at 650 V. The gas pressure ranges from 12 to 36 Torr of pure Ethylene. The work comes up as a need to obtain gas gain curves (Gas Multiplication Factors) for the proportional counter operated in the conditions as mentioned. This is a consequence of the scarcity of the existing information referred to Ethylene for the range of bias and gas pressure required in this case. Likewise, the research involved in this study contributed with useful information for the institution involved in the design and construction of the neutron dosimeter, as well as for the scientific community through the publication of this work. The results were obtained by using the above-mentioned Neutron Dosimeter but instead of using recoil protons by fast neutrons, the measurements were completed by directly using a 241 Am alpha particle source installed inside the dosimeter. The analysis of results as well as a detailed study of the pulse shapes provided by the proportional counter was performed by using the well-known MathCAD software. This software contains a text interface that includes symbolic and numeric calculations. Results of the research show that for the high Reduced Electric Fields ( Sa > 1500 Volts/cmTorr) used throughout the present work, Townsend law is still valid. This law states that the Multiplication Factors may be considered as dependent on the Reduced Electric Field instead of depending on the bias and gas pressure separately

  1. Low-cost positron computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.; Batty, V.; Bateman, T.E.; Clack, R.; Flower, M.A.; Leach, M.O.; Marsden, P.; Webb, S.; McCready, V.R.

    1986-01-01

    After briefly describing the technique of positron emission tomography (PET) and the types of detectors used, the operational experience of a recently developed multi-wire proportional chamber positron camera which can be used to provide images using radionuclides such as 68 Ga, 124 I, 82 Rb, 55 Co, 18 F and 11 C is discussed. Clinical applications included PET imaging of the thyroid and the brain and possible future applications include PET imaging of the liver and tumour localization using antigen-specific monoclonal antibodies. Future developments to improve the sensitivity and spatial resolution of the detectors used in PET are discussed. (U.K.)

  2. The upgrade of the multiwire drift chamber readout of the HADES experiment at GSI: the optical end point board

    Energy Technology Data Exchange (ETDEWEB)

    Tarantola, Attilio; Michel, Jan; Muentz, Christian; Stroth, Joachim [Institut fuer Kernphysik, Goethe-Universitaet, Frankfurt (Germany); GSI, Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Froehlich, Ingo; Stroebele, Herbert [Institut fuer Kernphysik, Goethe-Universitaet, Frankfurt (Germany); Kolb, Burkhard; Traxler, Michael [GSI, Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Palka, Marek [Smoluchowski Institute of Physics, Jagiellonian University, Krakow (Poland); GSI, Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Wuestenfeld, Joern [Institut fuer Strahlenphysik, Forschungszentrum, Dresden-Rossendorf (Germany)

    2009-07-01

    One of the goal of the HADES upgrade project is the realization of a new data acquisition scheme for the 24 Multiwire Drift Chambers (MDCs), which allows to increase the readout speed of the 40.000 TDC channels. On the existing MDC Front End Electronic (FEE) side an Optical End Point Board (OEPB) has been designed to control configuration and readout of the chamber's TDCs. The OEPB uses Plastic Optical Fibres (POF) for data transmission, which results in total electromagnetic immunity, amazing simplicity in handling and low power consumption. The employment of a Lattice ECP2/M FPGA with SERDES manages serial data transmission and its large resources allow for the storage of several events close-to-front-end. As 400 OEPBs will be located in the detector acceptance, dedicated FPGA hardware is used to detect Single Event Upsets (SEUs).

  3. New proportional counter assembly in Gliwice 14C laboratory

    International Nuclear Information System (INIS)

    Moscicki, W.; Zastawny, A.

    1977-01-01

    The design and parameters are described of a proportional counter for low level counting. The cathode tube 80 mm in diameter and 30 cm in length is made of pure copper. The anode is a tungsten wire 0.05 mm in diameter. The cathode tube is surrounded by a cylindrical ring container with mercury. The total volume of the counter is 1.5 l and it is filled with carbon dioxide. At a pressure of 1 at of CO 2 the counter background is 4.20+-0.05 cpm and contemporary 14 C net effect 10.22+-0.10 cpm; at a pressure of 2 at of CO 2 the background is 4.40+-0.05 cpm and the contemporary 14 C net effect 20.53+-10 cpm. The efficiency of the proportional counter is 88% in both cases. (J.B.)

  4. Operation of MWDC's in the QDD and QDQ focal planes

    International Nuclear Information System (INIS)

    Distelbrink, J.H.J.

    1980-01-01

    In the multiwire drift chamber (MWDC), the speed of a multiwire proportional chamber and the position accuracy of a drift chamber are combined. A solution to the problem of the curved electric field lines near the wires is discussed. (Auth.)

  5. Preliminary results from a high-pressure imaging spectroscopic proportional counter

    International Nuclear Information System (INIS)

    Hall, C.J.; Bazzano, A.; Lewis, R.A.; Parker, B.; Ubertini, P.; Worgan, J.S.

    1992-01-01

    A new type of high-pressure proportional counter, with both spatial resolution and spectroscopic capabilities is being jointly developed by the Istituto di Astrofisica Spaziale (CNR), Frascati, Italy and the SERC Daresbury Laboratory, Warrington, UK. The characteristics of the detector can be optimized for the particular requirement of the experiment, either for x-ray astronomy observations from space, or for the high count rate applications associated with a synchrotron light source. In its baseline configuration, the detector is filled to 5 bar with a xenon/quench gas mixture and will be sensitive over the energy range 5 keV to 150 keV (2.5 to 0.08 A). The positional resolution will range from 500 μm at the lower energies to around 1 mm at the higher end of the energy range. The current prototype has a sensitive area of 200x200 mm. The final version is hoped to have an area closer to 425x425 mm. The very small photon absorption length in the higher pressure gas allows the parallax effect, a feature of 1 atmosphere detectors, to be greatly reduced. The timing resolution (150 ns) of the detector enables both a high-rate capability and the possibility of the escape gate technique to achieve higher spectral resolution at energies > the Xe K edge. Preliminary results are presented showing the spectral and positional resolution for the prototype detector

  6. Conception and test of an integrated circuit (ASIC): application to multiwire chambers and photomultipliers of the GRAAL experience; Conception et test d`un circuit integre (ASIC): application aux chambres multifils et aux photomultiplicateurs de l`experience GRAAL

    Energy Technology Data Exchange (ETDEWEB)

    Bugnet, H.

    1995-11-21

    The nuclear physics project GRAAL (GRenoble Anneau Accelerateur Laser) located at the European Synchrotron Radiation Facility (ESRF) in Grenoble produces a high energy photon beam with a maximum energy of 1.5 GeV. This gamma beam is obtained by Compton backscattering and can be polarized easily. It permits to probe, in an original way, the structure of the nucleon. The associated detector system includes multiwire proportional chambers and scintillator hodoscopes. A kit of six ASICs (Application Specific Integrated Circuit) has been developed and used for the signal processing and data conditioning up to the level of the data acquisition. This integrated electronics can be mounted right on the detectors. Obvious advantages, due to the reduction of the length of the wires and the number of connections, are an improvement of the signal quality and an increase of the reliability. The Wire Processor (WP), ASIC designed and tested during this thesis, treats the signals from the chamber wires and the photomultipliers. In one chip, there are two identical channels permitting the amplification, the amplitude discrimination, the generation of a programmable delay and the writing in a two state memory in case of coincidence with an external strobe signal. The measurement of the multiwire chamber efficiency demonstrates the functioning of the WP, the data conditioning electronics, the data acquisition and the chamber itself. (author). 62 refs., 111 figs., 13 tabs.

  7. Recent developments in multi-wire fixed abrasive slicing technique (FAST). [for low cost silicon wafer production from ingots

    Science.gov (United States)

    Schmid, F.; Khattak, C. P.; Smith, M. B.; Lynch, L. D.

    1982-01-01

    Slicing is an important processing step for all technologies based on the use of ingots. A comparison of the economics of three slicing techniques shows that the fixed abrasive slicing technique (FAST) is superior to the internal diameter (ID) and the multiblade slurry (MBS) techniques. Factors affecting contact length are discussed, taking into account kerf width, rocking angle, ingot size, and surface speed. Aspects of blade development are also considered. A high concentration of diamonds on wire has been obtained in wire packs usd for FAST slicing. The material removal rate was found to be directly proportional to the pressure at the diamond tips.

  8. Identification of relativistic charged particles by means of ionisation energy loss in proportional counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1978-12-01

    A method is described of obtaining a useful degree of improvement in the particle discrimination capability of multiwire proportional counters. The normal multiple sampling technique using a suitable bias to combat the small magnitude of the relativistic rise in the ionization energy loss and the wide pulse height distributions obtained in thin gas counters requires a large number of samples for useful discrimination. In the method reported, this number is reduced by suppressing the delta ray contribution to the total charge pulse from the anode wire. A monte carlo model convoluting the 'delta ray suppressed' data from a one sample detector shows that when it is required to separate pions and electrons at 1 GeV/C with a detection efficiency for the electron of 90%, a 'suppressor' circuit can achieve a pion rejection ratio of 250:1 with 82 samples, whereas the truncated mean approach (lowest 70% of samples) requires 100 samples. (UK)

  9. A nuclear proportional counter

    International Nuclear Information System (INIS)

    1973-01-01

    The invention relates to a nuclear proportional counter comprising in a bulb filled with a low-pressure gas, a wire forming an anode and a cathode, characterized in that said cathode is constituted by two plane plates parallel to each other and to the anode wire, and in that two branches of a circuit are connected to the anode wire end-portions, each branch comprising a pre-amplifier, a measuring circuit consisting of a differentiator-integrator-differentiator amplifier and a zero detector, one of the branches comprising an adjustable delay circuit, both branches jointly attacking a conversion circuit for converting the pulse duration into amplitudes said conversion circuit being followed by a multi-channel analyzer, contingently provided with a recorder [fr

  10. Design and performance of a one square meter proportional counter system for hard X-ray astronomy

    International Nuclear Information System (INIS)

    Bazzano, A.; Boccaccini, L.; La Padula, C.D.; Mastropietro, M.; Patriarca, R.; Polcaro, F.; Ubertini, P.

    1983-01-01

    A versatile balloon borne hard X-ray experiment with a very large area (approx.= 1.1 m 2 ) and high spectral resolution has been developed for the study of the hard X-ray sources in the energy range 20-180 keV. The telescope consists of four multiwire proportional chambers (MWPC) that have a geometrical sensitive area of 2700 cm 2 each. The detector system has a sensitivity of approx.= 10 -5 photons cm -2 s -1 keV -1 during a typical balloon observation. A background rate of approx.= 3 x 10 -4 counts cm -2 s -1 keV -1 was observed in the operative energy range at 2.4 gm/cm 2 ceiling altitude and geographic latitude of 38 0 N. The design details, fabrication and flight performance of the instrument are briefly discussed with reference to the effectiveness of background reduction and other test parameters. (orig.)

  11. Position-sensitive proportional counter with low-resistance metal-wire anode

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which uses a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counther. A pair of specially designed activecapacitance preamplifiers terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, lownoise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at te anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates

  12. Low energy recoil detection with a spherical proportional counter

    Science.gov (United States)

    Savvidis, I.; Katsioulas, I.; Eleftheriadis, C.; Giomataris, I.; Papaevangellou, T.

    2018-01-01

    We present results for the detection of low energy nuclear recoils in the keV energy region, from measurements performed with the Spherical Proportional Counter (SPC). An 241Am-9Be fast neutron source is used in order to obtain neutron-nucleus elastic scattering events inside the gaseous volume of the detector. The detector performance in the keV energy region was measured by observing the 5.9 keV line of a 55Fe X-ray source, with energy resolution of 10% (σ). The toolkit GEANT4 was used to simulate the irradiation of the detector by an 241Am-9Be source, while SRIM was used to calculate the Ionization Quenching Factor (IQF), the simulation results are compared with the measurements. The potential of the SPC in low energy recoil detection makes the detector a good candidate for a wide range of applications, including Supernova or reactor neutrino detection and Dark Matter (WIMP) searches (via coherent elastic scattering).

  13. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Science.gov (United States)

    2010-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2010-10-01 2010-10-01 false Maximum and minimum allowable operating pressure...

  14. Controlling low-rate signal path microdischarge for an ultra-low-background proportional counter

    International Nuclear Information System (INIS)

    Mace, E.K.; Aalseth, C.E.; Bonicalzi, R.M.; Day, A.R.; Hoppe, E.W.; Keillor, M.E.; Myers, A.W.; Overman, C.T.; Seifert, A.

    2013-01-01

    Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ∼30 m water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ∼1 m of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors. (author)

  15. Investigation of low pressure ES-SAGD

    Energy Technology Data Exchange (ETDEWEB)

    Ivory, J.; Zheng, R.; Nasr, T.; Deng, X.; Beaulieu, G.; Heck, G. [Alberta Research Council, Edmonton, AB (Canada)

    2008-10-15

    This paper described a scaled model experiment conducted to investigate the effectiveness of expanding solvent steam assisted gravity drainage (ES-SAGD) processes at low pressures. Lower SAGD pressures typically result in reduced oil production as a result of correspondingly lower steam temperatures. However, lower pressures may also result in a reduced steam to oil ratio (SOR) and a higher vaporization heat. Steam was injected into an injection well at 33 cm{sup 3} per minute and in a production well at 31 cm{sup 3} per minute. Steam and solvents were then co-injected into the injection well at a temperature of 206 degrees C. The experiment was history-matched and a parametric analysis was conducted using a simulation tool. The 2-D and 3-D field-scale simulations investigated the impact of operating pressures, injection rates; sub-cool; oil and gas phase diffusion and dispersion; live oil versus dead oil performance; and the use of drawdown when oil rates declined. Low pressure ES-SAGD was then compared with low-pressure SAGD. Results of the study suggested that production pressures, sub-cool and solvent concentrations are important parameters in ES-SAGD processes. At 1500 kPa production pressure and 10 degrees C sub-cool, the co-injection of solvent with steam increased average oil rates by 15 per cent more than the SAGD process. SOR was also reduced. 6 refs., 8 tabs., 20 figs.

  16. Light yield as a function of gas pressure and electric field in gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Favata, F.; Smith, A.; Bavdaz, M.; Kowalski, T.Z.

    1990-01-01

    We have investigated the dependence of the scintillation light output for Xe on gas pressure in the range 0.14-1.4 bar, using a gas scintillation proportional counter, in different experimental configurations. We have compared our work with that of previous workers, and have shown that both our results and the results of previous authors are compatible with the intrinsic light output being independent of gas pressure, with any observed dependence being a pure experimental effect due to the spectral response of the various UV detectors used. We also use our experimental data for determining the ratio between the cross section of the Xe 2 ** +Xe→Xe 2 * +Xe reaction and the rate of the Xe 2 ** →2Xe+γ UV reaction. (orig.)

  17. Modeling low pressure baroreceptors and their contribution to blood pressure control

    Directory of Open Access Journals (Sweden)

    Sánchez de Zambrano, Betsy Mirley

    2016-10-01

    Full Text Available The main mechanism for blood pressure (BP control is coordinated by the central nervous system through the sympathetic and parasympathetic systems. In order to simulate this mechanism, different mathematical models are available, but they take into account only the high pressure receptors as sensing systems for BP. However, other receptors located in low pressure areas have not, as far as we know, been considered in the models described in the literature, despite their important role in the nervous BP control. This paper presents a mathematical model for the representation of low pressure receptors by means of the detection of atrial volume changes, and their contribution to immediate BP control through nervous stimulation of the heart rate. The proposed model was coupled to the sensor mechanism of a larger model. With this model it is possible to analyze the contribution and behavior of low pressure receptors, thus allowing a better understanding of this complex system under normal and pathological conditions, since it includes important variables in the immediate BP control, not included in previous models.

  18. Seed disinfection effect of atmospheric pressure plasma and low pressure plasma on Rhizoctonia solani.

    Science.gov (United States)

    Nishioka, Terumi; Takai, Yuichiro; Kawaradani, Mitsuo; Okada, Kiyotsugu; Tanimoto, Hideo; Misawa, Tatsuya; Kusakari, Shinichi

    2014-01-01

    Gas plasma generated and applied under two different systems, atmospheric pressure plasma and low pressure plasma, was used to investigate the inactivation efficacy on the seedborne pathogenic fungus, Rhizoctonia solani, which had been artificially introduced to brassicaceous seeds. Treatment with atmospheric plasma for 10 min markedly reduced the R. solani survival rate from 100% to 3% but delayed seed germination. The low pressure plasma treatment reduced the fungal survival rate from 83% to 1.7% after 10 min and the inactivation effect was dependent on the treatment time. The seed germination rate after treatment with the low pressure plasma was not significantly different from that of untreated seeds. The air temperature around the seeds in the low pressure system was lower than that of the atmospheric system. These results suggested that gas plasma treatment under low pressure could be effective in disinfecting the seeds without damaging them.

  19. Design and performance of a one square meter proportional counter system for hard X-ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Bazzano, A.; Boccaccini, L.; La Padula, C.D.; Mastropietro, M.; Patriarca, R.; Polcaro, F.; Ubertini, P. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale); Manchanda, R.K. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale; Tata Inst. of Fundamental Research, Bombay (India))

    1983-09-01

    A versatile balloon borne hard X-ray experiment with a very large area (approx.= 1.1 m/sup 2/) and high spectral resolution has been developed for the study of the hard X-ray sources in the energy range 20-180 keV. The telescope consists of four multiwire proportional chambers (MWPC) that have a geometrical sensitive area of 2700 cm/sup 2/ each. The detector system has a sensitivity of approx.= 10/sup -5/ photons cm/sup -2/ s/sup -1/ keV/sup -1/ during a typical balloon observation. A background rate of approx.= 3 x 10/sup -4/ counts cm/sup -2/ s/sup -1/ keV/sup -1/ was observed in the operative energy range at 2.4 gm/cm/sup 2/ ceiling altitude and geographic latitude of 38/sup 0/N. The design details, fabrication and flight performance of the instrument are briefly discussed with reference to the effectiveness of background reduction and other test parameters.

  20. Nanocomposite-Based Microstructured Piezoresistive Pressure Sensors for Low-Pressure Measurement Range

    Directory of Open Access Journals (Sweden)

    Vasileios Mitrakos

    2018-01-01

    Full Text Available Piezoresistive pressure sensors capable of detecting ranges of low compressive stresses have been successfully fabricated and characterised. The 5.5 × 5 × 1.6 mm3 sensors consist of a planar aluminium top electrode and a microstructured bottom electrode containing a two-by-two array of truncated pyramids with a piezoresistive composite layer sandwiched in-between. The responses of two different piezocomposite materials, a Multiwalled Carbon Nanotube (MWCNT-elastomer composite and a Quantum Tunneling Composite (QTC, have been characterised as a function of applied pressure and effective contact area. The MWCNT piezoresistive composite-based sensor was able to detect pressures as low as 200 kPa. The QTC-based sensor was capable of detecting pressures as low as 50 kPa depending on the contact area of the bottom electrode. Such sensors could find useful applications requiring the detection of small compressive loads such as those encountered in haptic sensing or robotics.

  1. Development of multiwire gas detectors for X-rays; Desenvolvimento de detectores a gas multifilares para raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Sales, Eraldo de

    2015-06-01

    This work presents the prototype of a 2D position sensitive gas detector for application in X-ray scattering and diffraction experiments. Starting from a detector initially developed for other applications and will show the required changes on the original concept of this device. The strategy used to determine the necessary adaptations were based on searching in the literature for the overall characteristics of a multi-wire X-ray detector (choice of gas, pressure, window, etc.), the use of simulations, implementation of the changes and finally operational tests. Computational tools were used to calculate the mechanical strength and attenuation of the X-ray photons that helped to determine the most appropriate material for the construction of the entrance window. Detector simulations were built with Garfield software and were used to study the overall properties of the detector, and to determine the optimum parameters for the equipment operation. Typical parameters are the distance between the wires, wire diameter, high voltage to be used, among several other parameters. The results obtained showed that the multi-wire detector concept with the implemented adaptations allowed the detection of X-rays. However, depending on the application, it may be necessary improve the resolution of the equipment, in order to have a better description of the collected data. Several ideas are suggested for this improvement. It is also presented interesting results obtained with a microscopic pattern detector called triple GEM. This device belongs to the Gas Detectors Development group (GDD group) at CERN and was used in my training at this institution. The results showed the potential of the equipment for detection of X-rays. The results and simulations presented in this work, confirmed that the changes in the concept of the original detector permitted it use on X-ray detection applications. Also, it was possible to obtain several indications for further optimization, which may

  2. Simulation of low pressure water hammer

    Science.gov (United States)

    Himr, D.; Habán, V.

    2010-08-01

    Numerical solution of water hammer is presented in this paper. The contribution is focused on water hammer in the area of low pressure, which is completely different than high pressure case. Little volume of air and influence of the pipe are assumed in water, which cause sound speed change due to pressure alterations. Computation is compared with experimental measurement.

  3. Shock tubes: compressions in the low pressure chamber

    International Nuclear Information System (INIS)

    Schins, H.; Giuliani, S.

    1986-01-01

    The gas shock tube used in these experiments consists of a low pressure chamber and a high pressure chamber, divided by a metal-diaphragm-to-rupture. In contrast to the shock mode of operation, where incident and reflected shocks in the low pressure chamber are studied which occur within 3.5 ms, in this work the compression mode of operation was studied, whose maxima occur (in the low pressure chamber) about 9 ms after rupture. Theoretical analysis was done with the finite element computer code EURDYN-1M, where the computation was carried out to 30 ms

  4. Low pressure lithium condensation

    International Nuclear Information System (INIS)

    Wadkins, R.P.; Oh, C.H.

    1985-01-01

    A low pressure experiment to evaluate the laminar film condensation coefficients of lithium was conducted. Some thirty-six different heat transfer tests were made at system pressures ranging from 1.3 to 26 Pa. Boiled lithium was condensed on the inside of a 7.6-cm (ID), 409 stainless-steel pipe. Condensed lithium was allowed to reflux back to the pool boiling region below the condensing section. Fourteen chromel/alumel thermocouples were attached in various regions of the condensing section. The thermocouples were initially calibrated with errors of less than one degree Celsius

  5. Ammonia Synthesis at Low Pressure.

    Science.gov (United States)

    Cussler, Edward; McCormick, Alon; Reese, Michael; Malmali, Mahdi

    2017-08-23

    Ammonia can be synthesized at low pressure by the use of an ammonia selective absorbent. The process can be driven with wind energy, available locally in areas requiring ammonia for synthetic fertilizer. Such wind energy is often called "stranded," because it is only available far from population centers where it can be directly used. In the proposed low pressure process, nitrogen is made from air using pressure swing absorption, and hydrogen is produced by electrolysis of water. While these gases can react at approximately 400 °C in the presence of a promoted conventional catalyst, the conversion is often limited by the reverse reaction, which makes this reaction only feasible at high pressures. This limitation can be removed by absorption on an ammine-like calcium or magnesium chloride. Such alkaline metal halides can effectively remove ammonia, thus suppressing the equilibrium constraints of the reaction. In the proposed absorption-enhanced ammonia synthesis process, the rate of reaction may then be controlled not by the chemical kinetics nor the absorption rates, but by the rate of the recycle of unreacted gases. The results compare favorably with ammonia made from a conventional small scale Haber-Bosch process.

  6. System transient analysis code development for low pressure and low power

    International Nuclear Information System (INIS)

    Kim, Hee Cheol

    1998-02-01

    A real time reactor system analysis code, ARTIST, based on drift flux model has been developed to investigate the transient system behavior under low pressure, low flow and low power conditions with noncondensable gas present in the system. The governing equations of the ARTIST code consist of three mass continuity equations (steam, liquid and noncondensable), two energy equations (gas and mixture) and one momentum equation (mixture) constituted with the drift flux model. The capability of ARTIST in predicting two-phase flow void distribution in the system has been validated against experimental data. The results of the ARTIST axial void distribution at low pressure and low flow, are far better than the results of both the homogeneous model of TASS code and the two-fluid model of RELAP5/MOD3 code. Also, RELAP5/MOD3 calculation shows the large amplitude of void fraction oscillations at low pressure. These results imply that interfacial momentum transfer terms in the two-fluid model formulation should be carefully constituted, especially for the low pressure condition due to the big density differences between steam and water. Thermal-hydraulic state solution scheme is developed when noncondensable gas exists. Numerical consistency and convergence of obtaining equilibrium state is tested with the ideal problems for various situations including very low partial pressure conditions. Calculated thermal-hydraulic state for each test shows consistent and expected behaviour. A new multi-layer back propagation network algorithm for calculating the departure from nucleate boiling ratio (DNBR) is developed and adopted in ARTIST code in order to have real-time DNBR evaluation by eliminating the tandem procedure of the transient DNBR calculation. The algorithm trained by different patterns generated by latin hypercube sampling method on the performance space is tested for the randomly sampled untrained data and the transient DNBR data. The uncertainty of the algorithm is

  7. Helium-filled proportional counter and its operation mechanism at low temperatures

    CERN Document Server

    Isozumi, Y; Kishimoto, S

    2002-01-01

    The operation mechanism of helium-filled proportional counter (HFPC) at about 4.2 K is explained. Unstable behavior of HFPC is caused by releasing secondary-electron from the cathode by four kinds of active particles such as He sub n sup + , non-resonance photon from excited helium atom, non-resonance photon from He sub 2 sup * (A sup 1 Su sup +) and He sub 2 sup m (a sup 3 Su sup +). On experiments of HFPC behavior at low temperature, the following facts were observed; 1) main charge formation process in the electron avalanche is direct ionization by electron without Hornbeck-Molnar process. Accordingly, the gas amplification factor becomes small at low temperature. 2) Stable helium cation is He sub 2 sup + at room temperature, but cluster at low temperature. Large after-pulse is observed in output signal depends on cluster ion. The probability of secondary-electron emission decreased. The gas gain increased with increasing anode voltage. 3) By decreasing reaction rate of atom and molecule collision at low t...

  8. Calibration of Relative Humidity Devices in Low-pressure, Low-temperature CO2 Environment

    Science.gov (United States)

    Genzer, Maria; Polkko, Jouni; Nikkanen, Timo; Hieta, Maria; Harri, Ari-Matti

    2017-04-01

    Calibration of relative humidity devices requires in minimum two humidity points - dry (0%RH) and (near)saturation (95-100%RH) - over the expected operational temperature and pressure range of the device. In terrestrial applications these are relatively easy to achieve using for example N2 gas as dry medium, and water vapor saturation chambers for producing saturation and intermediate humidity points. But for example in applications intended for meteorological measurements on Mars there is a need to achieve at least dry and saturation points in low-temperature, low-pressure CO2 environment. We have developed a custom-made, small, relatively low-cost calibration chamber able to produce both dry points and saturation points in Martian range pressure CO2, in temperatures down to -70°C. The system utilizes a commercially available temperature chamber for temperature control, vacuum vessels and pumps. The main pressure vessel with the devices under test inside is placed inside the temperature chamber, and the pressure inside is controlled by pumps and manual valves and monitored with a commercial pressure reference with calibration traceable to national standards. Air, CO2, or if needed another gas like N2, is used for filling the vessel until the desired pressure is achieved. Another pressure vessel with a dedicated pressure pump is used as the saturation chamber. This vessel is placed in the room outside the temperature chamber, partly filled with water and used for achieving saturated water vapor in room-temperature low-pressure environment. The saturation chamber is connected to the main pressure vessel via valves. In this system dry point, low-pressure CO2 environment is achieved by filling the main pressure vessel with dry CO2 gas until the desired pressure is achieved. A constant flow of gas is maintained with the pump and valves and monitored with the pressure reference. The saturation point is then achieved by adding some water vapor from the saturation

  9. Experimental study an a low pressure solar still

    International Nuclear Information System (INIS)

    Sriram, V.; Kalidasa Murugavel, K.; Samuel Hansen, R.

    2013-01-01

    In this work, a low pressure, single basin double slope Solar Still was fabricated and tested for different depths and with different wick and porous materials. A vacuum pump was used to maintain low pressure inside the still. External condenser was used to condense the vapor with raw water as cooling fluid. The performance of the low pressure still was compared with conventional still. The total production of the still was increased by 88.66% when a light cotton cloth was used as wick material in the basin along with minimum depth of water. (authors)

  10. A Low-Pressure Oxygen Storage System for Oxygen Supply in Low-Resource Settings.

    Science.gov (United States)

    Rassool, Roger P; Sobott, Bryn A; Peake, David J; Mutetire, Bagayana S; Moschovis, Peter P; Black, Jim Fp

    2017-12-01

    Widespread access to medical oxygen would reduce global pneumonia mortality. Oxygen concentrators are one proposed solution, but they have limitations, in particular vulnerability to electricity fluctuations and failure during blackouts. The low-pressure oxygen storage system addresses these limitations in low-resource settings. This study reports testing of the system in Melbourne, Australia, and nonclinical field testing in Mbarara, Uganda. The system included a power-conditioning unit, a standard oxygen concentrator, and an oxygen store. In Melbourne, pressure and flows were monitored during cycles of filling/emptying, with forced voltage fluctuations. The bladders were tested by increasing pressure until they ruptured. In Mbarara, the system was tested by accelerated cycles of filling/emptying and then run on grid power for 30 d. The low-pressure oxygen storage system performed well, including sustaining a pressure approximately twice the standard working pressure before rupture of the outer bag. Flow of 1.2 L/min was continuously maintained to a simulated patient during 30 d on grid power, despite power failures totaling 2.9% of the total time, with durations of 1-176 min (mean 36.2, median 18.5). The low-pressure oxygen storage system was robust and durable, with accelerated testing equivalent to at least 2 y of operation revealing no visible signs of imminent failure. Despite power cuts, the system continuously provided oxygen, equivalent to the treatment of one child, for 30 d under typical power conditions for sub-Saharan Africa. The low-pressure oxygen storage system is ready for clinical field trials. Copyright © 2017 by Daedalus Enterprises.

  11. Low diastolic blood pressure and adverse outcomes in heart failure with preserved ejection fraction.

    Science.gov (United States)

    Tsujimoto, Tetsuro; Kajio, Hiroshi

    2018-07-15

    It remains unknown whether a low diastolic blood pressure (DBP) increases the risks of cardiovascular events and death in patients with heart failure with preserved ejection fraction (HFpEF). We used data from the TOPCAT trial. The primary outcome was a composite of all-cause death, non-fatal myocardial infarction, non-fatal stroke, or hospitalization for heart failure. Hazard ratios (HRs) were analyzed for DBPs of <60, 60-69, 70-79, and ≥90 mm Hg in comparison with a DBP of 80-89 mm Hg using multivariable Cox proportional hazard models. This study included 3417 patients with HFpEF who had a controlled blood pressure. In the mean follow-up period of 3.0 years, 881 patients experienced at least one confirmed primary outcome event. Compared with patients with a DBP of 80-89 mm Hg, the adjusted HRs for primary outcome events were significantly higher in those with DBPs of <60 mm Hg (HR: 2.19 [95% confidence interval,1.72-2.78]) and 60-69 mm Hg (HR: 1.52 [1.23-1.87]). Similarly, the adjusted HRs for all-cause death, major cardiovascular events, and hospitalization for heart failure, but not stroke, were significantly higher in patients with a DBP of <70 mm Hg. A relationship between a low DBP and adverse outcomes was found in HFpEF patients with a systolic blood pressure of ≥120 mm Hg; however, a low systolic blood pressure with a DBP of ≥70 mm Hg was not associated with these event risks. A low DBP increased the risks of adverse outcomes in patients with HFpEF. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Germination and growth of lettuce (Lactuca sativa) at low atmospheric pressure

    Science.gov (United States)

    Spanarkel, Robert; Drew, Malcolm C.

    2002-01-01

    The response of lettuce (Lactuca sativa L. cv. Waldmann's Green) to low atmospheric pressure was examined during the initial 5 days of germination and emergence, and also during subsequent growth to vegetative maturity at 30 days. Growth took place inside a 66-l-volume low pressure chamber maintained at 70 kPa, and plant response was compared to that of plants in a second, matching chamber that was at ambient pressure (approximately 101 kPa) as a control. In other experiments, to determine short-term effects of low pressure transients, plants were grown at ambient pressure until maturity and then subjected to alternating periods of 24 h of low and ambient atmospheric pressures. In all treatments the partial pressure of O2 was maintained at 21 kPa (approximately the partial pressure in air at normal pressure), and the partial pressure of CO2 was in the range 66.5-73.5 Pa (about twice that in normal air) in both chambers, with the addition of CO2 during the light phase. With continuous exposure to low pressure, shoot and root growth was at least as rapid as at ambient pressure, with an overall trend towards slightly greater performance at the lower pressure. Dark respiration rates were greater at low pressure. Transient periods at low pressure decreased transpiration and increased dark respiration but only during the period of exposure to low pressure. We conclude that long-term or short-term exposure to subambient pressure (70 kPa) was without detectable detriment to vegetative growth and development.

  13. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  14. Performance Analysis of Abrasive Waterjet Machining Process at Low Pressure

    Science.gov (United States)

    Murugan, M.; Gebremariam, MA; Hamedon, Z.; Azhari, A.

    2018-03-01

    Normally, a commercial waterjet cutting machine can generate water pressure up to 600 MPa. This range of pressure is used to machine a wide variety of materials. Hence, the price of waterjet cutting machine is expensive. Therefore, there is a need to develop a low cost waterjet machine in order to make the technology more accessible for the masses. Due to its low cost, such machines may only be able to generate water pressure at a much reduced rate. The present study attempts to investigate the performance of abrasive water jet machining process at low cutting pressure using self-developed low cost waterjet machine. It aims to study the feasibility of machining various materials at low pressure which later can aid in further development of an effective low cost water jet machine. A total of three different materials were machined at a low pressure of 34 MPa. The materials are mild steel, aluminium alloy 6061 and plastics Delrin®. Furthermore, a traverse rate was varied between 1 to 3 mm/min. The study on cutting performance at low pressure for different materials was conducted in terms of depth penetration, kerf taper ratio and surface roughness. It was found that all samples were able to be machined at low cutting pressure with varied qualities. Also, the depth of penetration decreases with an increase in the traverse rate. Meanwhile, the surface roughness and kerf taper ratio increase with an increase in the traverse rate. It can be concluded that a low cost waterjet machine with a much reduced rate of water pressure can be successfully used for machining certain materials with acceptable qualities.

  15. Effect of high pressure hydrogen on low-cycle fatigue

    International Nuclear Information System (INIS)

    Rie, K.T.; Kohler, W.

    1979-01-01

    It has been shown that the fatigue life can be influenced in low-cycle range by high pressure hydrogen while the effect of high pressure hydrogen on high-cycle fatigue will not be as significant. The paper reports the details and the results of the investigations of the effect of high pressure hydrogen on the low-cycle endurance of commercially pure titanium. The results of this study indicate that: 1. The degradation of the fatigue life in low-cycle region for commercially pure titanium under high pressure hydrogen can be described by Nsub(cr)sup(α x Δepsilon)sub(pl)sup(=c) 2. The fatigue life decreases with decreasing strain rate. 3. The fatigue life decreases with increasing hydrogen pressure. It was found that the semilogarithmic plot of the fatigue life versus the hydrogen pressure gives a linear relationship. The Sievert's law does not hold in low-cycle fatigue region. 4. HAC in titanium in low-cycle fatigue region is the result of the disolution of hydrogen at the crack tip and of the strain-induced hybride formation. (orig.) 891 RW/orig. 892 RKD [de

  16. Modeling low pressure baroreceptors and their contribution to blood pressure control

    OpenAIRE

    Sánchez de Zambrano, Betsy Mirley; Rojas-Sulbarán, Rubén Darío

    2016-01-01

    The main mechanism for blood pressure (BP) control is coordinated by the central nervous system through the sympathetic and parasympathetic systems. In order to simulate this mechanism, different mathematical models are available, but they take into account only the high pressure receptors as sensing systems for BP. However, other receptors located in low pressure areas have not, as far as we know, been considered in the models described in the literature, despite their important role in the ...

  17. Low pressure cooling seal system for a gas turbine engine

    Science.gov (United States)

    Marra, John J

    2014-04-01

    A low pressure cooling system for a turbine engine for directing cooling fluids at low pressure, such as at ambient pressure, through at least one cooling fluid supply channel and into a cooling fluid mixing chamber positioned immediately downstream from a row of turbine blades extending radially outward from a rotor assembly to prevent ingestion of hot gases into internal aspects of the rotor assembly. The low pressure cooling system may also include at least one bleed channel that may extend through the rotor assembly and exhaust cooling fluids into the cooling fluid mixing chamber to seal a gap between rotational turbine blades and a downstream, stationary turbine component. Use of ambient pressure cooling fluids by the low pressure cooling system results in tremendous efficiencies by eliminating the need for pressurized cooling fluids for sealing this gap.

  18. Non-equilbrium behavior of low-pressure plasma jets

    International Nuclear Information System (INIS)

    Chang, C.H.; Pfender, E.

    1989-01-01

    After establishing the basic equations, some sample calculations are presented to examine the thermodynamic state of the plasma from atmospheric to low pressures (80 mbar). These results indicate the validity of local thermodynamic equilibrium (LTE) at atmospheric pressure as well as strong deviations from LTE at lower pressures especially in terms of chemical equilibrium. Departures from kinetic equilibrium are not as severe as those from chemical equilibrium along the centerline of the jet. However, there are some departures from transitional equilibrium in the fringes of the jet. It is demonstrated that conventional methods based on the LTE assumption are not appropriate for describing low-pressure plasma jets

  19. Testing of low pressure proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Bettoni, M; Naso, V; Lucentini, M; Rubini, L

    1998-07-01

    One of the main issues concerning PEMFC is the choice of operating pressure, for both stationary and automotive applications. This is because the air compressor may absorb a significant amount--up to 25%--of the power output of the fuel cells stack. A comparison has been made between the performance of various stacks of different dimensions, tested in the De Nora Laboratories operated at high (4 bar) and low (1.5 bar) pressures, considering power output reduced by the compressor power absorption. Differences of performance and efficiency between high and low pressure stacks have been noticed in the range of 10%. In operating at low pressure, higher efficiency is obtainable, but the maximum power of the stack is less; this means less fuel consumption, but requires a greater reacting surface and larger dimension of the stack. Consequently low pressures make the system simpler (a blower can be used instead of a compressor), and safer (there is practically no risk of breaking the membrane).

  20. The one square meter hard X-ray (15-200 KeV) sky survey

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; La Padula, C.D.; Polcaro, V.F.

    1981-01-01

    A long term program was started at I.A.S. since 1979 to perform a survey of the hard X-ray sky using multiwire high pressure Xenon filled Spectroscopic Proportional Counters (SPC). The first payload consisting of two very large area SPC (2,700 cm 2 each) was flown during summer 1980 from the Milo Base (Sicily, Italy). The instrument duplicated to reach 10,800 cm 2 geometric area is expected to fly from northern (1981), southern (1982) and equatorial (1983) bases to perform a deep sky survey

  1. Prospective assessment of the frequency of low gradient severe aortic stenosis with preserved left ventricular ejection fraction: Critical impact of aortic flow misalignment and pressure recovery phenomenon.

    Science.gov (United States)

    Ringle, Anne; Castel, Anne-Laure; Le Goffic, Caroline; Delelis, François; Binda, Camille; Bohbot, Yohan; Ennezat, Pierre Vladimir; Guerbaai, Raphaëlle A; Levy, Franck; Vincentelli, André; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre

    2018-02-10

    The frequency of paradoxical low-gradient severe aortic stenosis (AS) varies widely across studies. The impact of misalignment of aortic flow and pressure recovery phenomenon on the frequency of low-gradient severe AS with preserved left ventricular ejection fraction (LVEF) has not been evaluated in prospective studies. To investigate prospectively the impact of aortic flow misalignment by Doppler and lack of pressure recovery phenomenon correction on the frequency of low-gradient (LG) severe aortic stenosis (AS) with preserved LVEF. Aortic jet velocities and mean pressure gradient (MPG) were obtained by interrogating all windows in 68 consecutive patients with normal LVEF and severe AS (aortic valve area [AVA] ≤1cm 2 ) on the basis of the apical imaging window alone (two-dimensional [2D] apical approach). Patients were classified as having LG or high-gradient (HG) AS according to MPG 35mL/m 2 or ≤35mL/m 2 , on the basis of the 2D apical approach, the multiview approach (multiple windows evaluation) and AVA corrected for pressure recovery. The proportion of LG severe AS was 57% using the 2D apical approach alone. After the multiview approach and correction for pressure recovery, the proportion of LG severe AS decreased from 57% to 13% (LF-LG severe AS decreased from 23% to 3%; NF-LG severe AS decreased from 34% to 10%). As a result, 25% of patients were reclassified as having HG severe AS (AVA ≤1cm 2 and MPG ≥40mmHg) and 19% as having moderate AS. Hence, 77% of patients initially diagnosed with LG severe AS did not have "true" LG severe AS when the multiview approach and the pressure recovery phenomenon correction were used. Aortic flow misevaluation, resulting from lack of use of multiple windows evaluation and pressure recovery phenomenon correction, accounts for a large proportion of incorrectly graded AS and considerable overestimation of the frequency of LG severe AS with preserved LVEF. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. Quality Management and Control of Low Pressure Cast Aluminum Alloy

    Science.gov (United States)

    Zhang, Dianxi; Zhang, Yanbo; Yang, Xiufan; Chen, Zhaosong; Jiang, Zelan

    2018-01-01

    This paper briefly reviews the history of low pressure casting and summarizes the major production processes of low pressure casting. It briefly introduces the quality management and control of low pressure cast aluminum alloy. The main processes include are: preparation of raw materials, Melting, refining, physical and chemical analysis, K-mode inspection, sand core, mold, heat treatment and so on.

  3. Low-pressure hydraulic technique for slurrying radioactive sludges in waste tanks

    International Nuclear Information System (INIS)

    Bradley, R.F.; Parsons, F.A.; Goodlett, C.B.; Mobley, R.M.

    1977-11-01

    Present technology for the removal of sludges from radioactive liquid waste storage tanks at the Savannah River Plant (SRP) requires large volumes of fresh water added through high-pressure (approx.3000 psig) nozzles positioned to resuspend and slurry the sludge. To eliminate the cost of storing and evaporating these large volumes of water (several hundred thousand gallons per tank cleaned), a technique was developed at the Savannah River Laboratory (SRL) to use recirculating, radioactive, supernate solution to resuspend the sludge. The system consists in part of a single-stage centrifugal pump operating in the sludge at approx.100 psia. Recirculating supernate is drawn into the bottom of the pump and forced out through two oppositely directed nozzles to give liquid jets with a sludge-slurrying capability equal to that obtained with the present high-pressure system. In addition to eliminating the addition of large quantities of water to the tanks, the low-pressure recirculating technique requires only approximately one-sixth of the power required by the high-pressure system. Test results with clay (as a simulant for sludge) in a waste tank mockup confirmed theoretical predictions that jets with the same momentum gave essentially the same sludge-slurrying patterns. The effective cleaning radius of the recirculating jet was directly proportional to the product of the nozzle velocity and the nozzle diameter (U 0 D). At the maximum U 0 D developed by the pump (approx.14 ft 2 /s), the effective cleaning radius in the tank mockup was approx.20 feet

  4. Line pressure effects on differential pressure measurements

    International Nuclear Information System (INIS)

    Neff, G.G.; Evans, R.P.

    1982-01-01

    The performance of differential pressure transducers in experimental pressurized water reactor (PWR) systems was evaluated. Transient differential pressure measurements made using a simple calibration proportionality relating differential pressure to output voltage could have large measurement uncertainties. A more sophisticated calibration equation was derived to incorporate the effects of zero shifts and sensitivity shifts as pressure in the pressure sensing line changes with time. A comparison made between the original calibration proportionality equation and the derived compensation equation indicates that potential measurement uncertainties can be reduced

  5. Properties of thick GEM in low-pressure deuterium

    International Nuclear Information System (INIS)

    Lee, C S; Ota, S; Tokieda, H; Kojima, R; Watanabe, Y N; Uesaka, T

    2014-01-01

    Deuteron inelastic scattering (d, d') provides a promising spectroscopic tool to study nuclear incompressibility. In studies of deuteron inelastic scattering of unstable nuclei, measurements of low-energy recoiled particles is very important. In order to perform these measurements, we are developing a GEM-TPC based gaseous active target, called CAT (Center for nuclear study Active Target), operated with pure deuterium gas. The CAT has been tested with deuterium gas at 1 atm and 100-μm-thick GEMs. The low-pressure operation of CAT is planned in order to improve the detection capability for lower-energy recoil particles. A 400 μm-thick gas electron multiplier (THGEM) was chosen for the low-pressure operation of CAT. However, the properties of THGEM in low-pressure deuterium are currently undocumented. In this work, the performance of THGEM with low-pressure pure deuterium gas has been investigated. The effective gas gain of THGEM has been measured in various conditions using a 5.5-MeV 241 Am alpha source. The effective gas gain was measured for 0.2-, 0.3- and 0.4-atm deuterium gas and a gas gain of about 10 3 was achieved by a double THGEM structure at 0.2 atm. The maximum achieved gain decreased with increasing gas pressure. The dependences of the effective gas gain on the electric field strengths of the drift, transfer and induction regions were investigated. The gain stability as a function of time in hydrogen gas was also tested and a relaxation time of THGEM of about 60 hours was observed with a continuous irradiation of alpha particles, which is significantly longer than previous studies have reported. We have tried to evaluate the gas gain of THGEM in deuterium gas by considering only the Townsend ionization process; however, it turned out that more phenomenological aspects, such as transfer efficiency, should be included in the evaluation. The basic properties of THGEM in low-pressure deuterium have been investigated for the first time

  6. Properties of thick GEM in low-pressure deuterium

    Science.gov (United States)

    Lee, C. S.; Ota, S.; Tokieda, H.; Kojima, R.; Watanabe, Y. N.; Uesaka, T.

    2014-05-01

    Deuteron inelastic scattering (d, d') provides a promising spectroscopic tool to study nuclear incompressibility. In studies of deuteron inelastic scattering of unstable nuclei, measurements of low-energy recoiled particles is very important. In order to perform these measurements, we are developing a GEM-TPC based gaseous active target, called CAT (Center for nuclear study Active Target), operated with pure deuterium gas. The CAT has been tested with deuterium gas at 1 atm and 100-μm-thick GEMs. The low-pressure operation of CAT is planned in order to improve the detection capability for lower-energy recoil particles. A 400 μm-thick gas electron multiplier (THGEM) was chosen for the low-pressure operation of CAT. However, the properties of THGEM in low-pressure deuterium are currently undocumented. In this work, the performance of THGEM with low-pressure pure deuterium gas has been investigated. The effective gas gain of THGEM has been measured in various conditions using a 5.5-MeV 241Am alpha source. The effective gas gain was measured for 0.2-, 0.3- and 0.4-atm deuterium gas and a gas gain of about 103 was achieved by a double THGEM structure at 0.2 atm. The maximum achieved gain decreased with increasing gas pressure. The dependences of the effective gas gain on the electric field strengths of the drift, transfer and induction regions were investigated. The gain stability as a function of time in hydrogen gas was also tested and a relaxation time of THGEM of about 60 hours was observed with a continuous irradiation of alpha particles, which is significantly longer than previous studies have reported. We have tried to evaluate the gas gain of THGEM in deuterium gas by considering only the Townsend ionization process; however, it turned out that more phenomenological aspects, such as transfer efficiency, should be included in the evaluation. The basic properties of THGEM in low-pressure deuterium have been investigated for the first time.

  7. Concentrator bifacial crystalline silicon solar cells with multi-wire metallization attached to TCO layers using transparent conductive polymers

    Science.gov (United States)

    Untila, Gennady; Chebotareva, Alla; Kost, Tatiana; Salazkin, Sergei; Shaposhnikova, Vera; Shvarts, Maxim

    2017-09-01

    Replacing expensive silver with inexpensive copper for the metallization of silicon wafer solar cells can lead to substantial reductions in material costs associated with cell production. A promising approach is the use of multi-wire design. This technology uses many wires in the place of busbars, and the copper wires are "soldered" during the low-temperature lamination process to the fingers (printed or plated) or to the transparent conductive oxide (TCO) layer, e.g. in the case of the α-Si/c-Si heterojunction cells. Here we describe a solar cell design in which wires are attached to TCO layers using transparent conductive polymer (TCP) films. To this end, we have synthesized a number of thermoplastics, poly(arylene ether ketone) copolymers (co-PAEKs), containing phthalide in their main chain. The fraction of phthalide-containing units in the copolymers was p = 3, 5, 15, and 50 mol %. With increasing p, the peak strain temperature of the co-PAEKs rises from 205 to 290 °C and their optical band gap and refractive index increase from 3.12 to 3.15 eV and from 1.6 to 1.614, respectively. The copolymers have a negligible absorption coefficient in the wavelength range 400- 1100 nm. When exposed to an excess pressure of 1 atm or above, co-PAEK films less than 30 µm in thickness undergo a transition from a dielectric to a conductive state. The resistivity (ρC) of wire/TCP/TCO (ITO = In2O3:Sn and IFO = In2O3:F) contacts ranges from 0.37 to 1.43 mΩ cm2. The polymer with the highest phthalide content (p = 50 mol %) has the lowest ρC. The average work of adhesion per unit area determined by pulling off the wires from the polymer surface depends on both the phthalide content of the co-PAEKs and their reduced viscosity, ranging from 14.3 to 43.5 N/cm. The highest value was obtained for the co-PAEK with p = 50 mol %. We have fabricated low-concentration bifacial IFO/(n+pp+)Cz-Si/ITO solar cells with a wire contact grid attached to IFO and ITO using a co-PAEK film. The

  8. Is the use of low-pressure pulsatile lavage for pressure ulcer management associated with environmental contamination with Acinetobacter baumannii?

    Science.gov (United States)

    Ho, Chester H; Johnson, Tova; Miklacic, Joan; Donskey, Curtis J

    2009-10-01

    Ho CH, Johnson T, Miklacic J, Donskey CJ. Is the use of low-pressure pulsatile lavage for pressure ulcer management associated with environmental contamination with Acinetobacter baumannii? To determine the extent of environmental contamination associated with low-pressure pulsatile lavage of stage III or IV pressure ulcers in patients with spinal cord injury (SCI) when routine infection control precautions are used for wounds colonized or infected with Acinetobacter baumannii. Prospective investigation in which pressure ulcer cultures and environmental cultures were obtained before and after low-pressure pulsatile lavage treatment, and before and after regular dressing changes. Environmental cultures included the patient's bedrail and settle plates placed 0.6, 1.5, and 2.4m from the wound to assess airborne spread of A. baumannii. SCI inpatient unit in a Department of Veterans Affairs Medical Center. Inpatients (N=15) with SCI receiving daily low-pressure pulsatile lavage treatment for stage III or IV pressure ulcers with standard dressing change, as well as regular dressing changes without low-pressure pulsatile lavage at other times of the day. Standard, regular dressing changes and dressing changes with low-pressure pulsatile lavage. Comparison of frequency of environmental contamination with A. baumannii associated with low-pressure pulsatile lavage versus regular dressing changes. Of the 15 SCI inpatients meeting inclusion criteria, 9 (60%) grew A. baumannii from their wounds. Of the 9 patients with wound cultures positive for A. baumannii, only 1 (11%) had environmental contamination with this organism after performance of low-pressure pulsatile lavage, and the same patient had environmental contamination after a standard dressing change. The antibiotic susceptibility patterns of the wound and environmental A. baumannii isolates were identical. Low-pressure pulsatile lavage using the infection control methods described is not associated with an increased

  9. Exploring the limits: A low-pressure, low-temperature Haber-Bosch process

    Science.gov (United States)

    Vojvodic, Aleksandra; Medford, Andrew James; Studt, Felix; Abild-Pedersen, Frank; Khan, Tuhin Suvra; Bligaard, T.; Nørskov, J. K.

    2014-04-01

    The Haber-Bosch process for ammonia synthesis has been suggested to be the most important invention of the 20th century, and called the ‘Bellwether reaction in heterogeneous catalysis’. We examine the catalyst requirements for a new low-pressure, low-temperature synthesis process. We show that the absence of such a process for conventional transition metal catalysts can be understood as a consequence of a scaling relation between the activation energy for N2 dissociation and N adsorption energy found at the surface of these materials. A better catalyst cannot obey this scaling relation. We define the ideal scaling relation characterizing the most active catalyst possible, and show that it is theoretically possible to have a low pressure, low-temperature Haber-Bosch process. The challenge is to find new classes of catalyst materials with properties approaching the ideal, and we discuss the possibility that transition metal compounds have such properties.

  10. Effect of low-pressure plasma treatment on the color and oxidative stability of raw pork during refrigerated storage.

    Science.gov (United States)

    Ulbin-Figlewicz, Natalia; Jarmoluk, Andrzej

    2016-06-01

    The effect of low-pressure plasma on quality attributes of meat is an important aspect, which must be considered before application in food. The aim of this study was to determine the color, fatty acid composition, lipid oxidation expressed as thiobarbituric acid reactive substances and total antioxidant capacity of raw pork samples exposed to helium low-pressure plasma treatment (20 kPa) for 0, 2, 5, and 10 min during the storage period. The thiobarbituric acid reactive substance concentrations of all plasma-treated samples during storage were in the range from 0.26 to 0.61 mg malondialdehyde/kg. Exposure time caused significant changes only in total color difference, hue angle, and chroma after 10 min of treatment. Ferric reducing ability of plasma values of meat samples decreased from 1.93 to 1.40 mmol Trolox Eq/kg after 14 days of storage. The storage period significantly affected proportion of polyunsaturated fatty acids, with an increase about 3% after 14 days of refrigeration storage while the content of saturated fatty acids was at the same level. Helium low-pressure plasma does not induce oxidative processes. Application of this decontamination technique while maintaining product quality is possible in food industry. © The Author(s) 2015.

  11. Digital pulse-shape discrimination applied to an ultra-low-background gas-proportional counting system. First results

    International Nuclear Information System (INIS)

    Aalseth, C.E.; Day, A.R.; Fuller, E.S.; Hoppe, E.W.; Keillor, M.E.; Mace, E.K.; Myers, A.W.; Overman, C.T.; Panisko, M.E.; Seifert, A.

    2013-01-01

    A new ultra-low-background proportional counter design was recently developed at Pacific Northwest National Laboratory (PNNL). This design, along with an ultra-low-background counting system which provides passive and active shielding with radon exclusion, has been developed to complement a new shallow underground laboratory (∼30 m water-equivalent) constructed at PNNL. After these steps to mitigate dominant backgrounds (cosmic rays, external gamma-rays, radioactivity in materials), remaining background events do not exclusively arise from ionization of the proportional counter gas. Digital pulse-shape discrimination (PSD) is thus employed to further improve measurement sensitivity. In this work, a template shape is generated for each individual sample measurement of interest, a 'self-calibrating' template. Differences in event topology can also cause differences in pulse shape. In this work, the temporal region analyzed for each event is refined to maximize background discrimination while avoiding unwanted sensitivity to event topology. This digital PSD method is applied to sample and background data, and initial measurement results from a biofuel methane sample are presented in the context of low-background measurements currently being developed. (author)

  12. Magnesium based composites fabricated by low pressure infiltration

    International Nuclear Information System (INIS)

    Johansson, P.; Micski, A.; Savage, S.J.

    1993-01-01

    Magnesiumbased fiber composites have been produced by so called low pressure infiltration. The initial material consist of 'saffil' pre-forms and two magnesium alloys, Mg-9Al-1Zn and WE 54 (approximate composition Mg-5Y-1.5Nd-2(Tb,Er,Dy,Gd)-0.5Zr), and pure magnesium. The preforms consists of 10-30 vol% of short fibers linked together by SiO 2 or Al 2 O 3 . Three different routes have been tested in the search for a good low pressure infiltration method. The experiments cover corrosion testing in NaCl-solution, sliding wear, abrasion and erosion testing. Of the tested infiltration methods the best results were obtained in a resistance heated evacuable furnace, in which the metal was molted in a steel crucible and the preform was conveyed into the melt under protective atmosphere. The infiltration takes place at atmospheric pressure and the cooling is performed in a sealed tube in air. The microscopy studies shows that low pressure infiltrated composites contain considerable amounts of porosity in distinction from those fabricated by squeeze casting. The corrosion test has shown that in the tested environment the alloy WE 54 has good corrosion resistance while Mg-9Al-1Zn and pure magnesium show low corrosion resistance. The influence of fibres in the matrix seems to be very small. Both magnesium and the alloy Mg-9Al-1Zn show for two body abrasion an almost linear improvement of abrasion resistance with increased fiber content. Pure magnesium shows decreasing erosion resistance with increasing fibre content. The Mg-9Al-1Zn-alloy appears to show a maximum in erosion resistance at 10 vol% fibers. In sliding wear the materials show an optimum initial and steady state wear resistance at a fiber content of about 10%. In general Al 2 O 3 -binder gives better wear resistance than SiO 2 -binder. Tensile testing was performed on low pressure infiltrated and squeeze cast composites with WE 54 matrix. It shows that the low pressure infiltrated composites are inferior to those

  13. Materials and proportion's design of self-compacting mortar used for low diffusion layer in sub-surface radioactive waste disposal facility in Japan

    International Nuclear Information System (INIS)

    Niwase, Kazuhito; Sugihashi, Naoyuki; Tsuji, Yukikazu

    2010-01-01

    This paper describes the design procedure for the material selection and mix proportion of the self-compacting mortar used for low diffusion layer cementitious material in the sub-surface radioactive waste disposal facility in Japan. The low diffusion layer is required for reducing transportation by controlling diffusion of a radionuclide. Therefore the low diffusion, cracks control, and low leaching are the important matters in the mix design. The process to select mortar mix design of the low diffusion layer is explained in detail. Of 33 kinds mix proportions used in laboratory comparative testing, the combinations of low heat portland cement, fly ash, lime powder and expansive addition was provisionally set to the mix proportion of the self-compacting mortar used for low diffusion layer. (author)

  14. Study of the low pressure (Black Phase) SmS properties

    International Nuclear Information System (INIS)

    Bordier, G.

    1987-03-01

    SmS has been studied for its transition from the low pressure black phase to the high pressure intermediate valence phase; but the black phase properties seem to be very rich. The variations which pressure of the low-temperature electronic transport properties show the existence of a semi-metallic phase within the black phase domain in a pressure-temperature diagram, for a pressure above 4 kbar, which corresponds to the so-called B'phase. We study the insulating low pressure phase with a model involving acceptor like states. Using electronic paramagnetic resonance experiments we observe a square symmetry trivalent samarium ion neighbour of a sulfure defect, and magnetically coupled with the lattice. This defect exists in two nearly symmetric configurations and the resonance line broadens with temperature in an actived way. It gives rise to metastable effects yielding conductivity relaxations, analysed with stretched exponential laws, because the defect traps magnetically conduction electrons forming a bound magnetic polaron. The relaxation time at zero field is temperature actived. We develop a phenomenological model that gives the good orders of magnitude for the trapping barrier and for the critical field corresponding to the maximum of the low temperature magnetoresistance [fr

  15. First experimental results and simulation for gas optimisation of the MART-LIME detector

    International Nuclear Information System (INIS)

    Bazzano, A.; Brunetti, M.T.; Cocchi, M.; Hall, C.J.; Lewis, R.A.; Natalucci, L.; Ortuno-Prados, F.; Ubertini, P.

    1996-01-01

    A large area high pressure multi-wire proportional counter (MWPC), with both spatial and spectroscopic capabilities, is being jointly developed by the Istituto di Astrofisica Spaziale (IAS), CNR, Frascati, Italy and the Daresbury Laboratory (DL), Warrington, UK as part of the MART-LIME telescope. Recent test results (October-December 1995) carried out at the DL facilities are presented. A brief study, by means of a simulation program, on the possible gas mixtures to be employed in the MART-LIME detector is also reported. The results of the simulation are compared with the experimental data obtained from the tests. (orig.)

  16. A Mott polarimeter for the search of time reversal violation in the decay of free neutrons

    International Nuclear Information System (INIS)

    Ban, G.; Beck, M.; Bialek, A.; Bodek, K.; Gorel, P.; Kirch, K.; Kistryn, St.; Kozela, A.; Kuzniak, M.; Lindroth, A.; Naviliat-Cuncic, O.; Pulut, J.; Severijns, N.; Stephan, E.; Zejma, J.

    2006-01-01

    A new polarimeter for low-energy electrons has been built and tested. The device was developed for the measurement of the transverse polarization of beta particles emitted in the decay of polarized cold neutrons. The decay electrons are identified by multi-wire proportional chambers made of low-Z materials and are detected with plastic scintillator hodoscopes. The transverse polarization is analyzed by means of large angle Mott scattering on a thin Pb foil. We describe here the elements of the apparatus and present the results of test measurements which illustrate its performance

  17. A Mott polarimeter for the search of time reversal violation in the decay of free neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Ban, G. [Laboratoire de Physique Corpusculaire, Caen (France); Beck, M. [Catholic University, Leuven (Belgium); Bialek, A. [Institute of Physics, Polish Academy of Sciences, Cracow (Poland); Bodek, K. [Institute of Physics, Jagiellonian University, Cracow (Poland)]. E-mail: ufbodek@if.uj.edu.pl; Gorel, P. [Laboratoire de Physique Corpusculaire, Caen (France); Paul Scherrer Institute, Villigen (Switzerland); Kirch, K. [Paul Scherrer Institute, Villigen (Switzerland); Kistryn, St. [Institute of Physics, Jagiellonian University, Cracow (Poland); Kozela, A. [Institute of Physics, Polish Academy of Sciences, Cracow (Poland); Kuzniak, M. [Institute of Physics, Jagiellonian University, Cracow (Poland); Lindroth, A. [Catholic University, Leuven (Belgium); Naviliat-Cuncic, O. [Laboratoire de Physique Corpusculaire, Caen (France); Pulut, J. [Institute of Physics, Jagiellonian University, Cracow (Poland); Paul Scherrer Institute, Villigen (Switzerland); Catholic University, Leuven (Belgium); Severijns, N. [Catholic University, Leuven (Belgium); Stephan, E. [Institute of Physics, University of Silesia, Katowice (Poland); Zejma, J. [Institute of Physics, Jagiellonian University, Cracow (Poland)

    2006-09-15

    A new polarimeter for low-energy electrons has been built and tested. The device was developed for the measurement of the transverse polarization of beta particles emitted in the decay of polarized cold neutrons. The decay electrons are identified by multi-wire proportional chambers made of low-Z materials and are detected with plastic scintillator hodoscopes. The transverse polarization is analyzed by means of large angle Mott scattering on a thin Pb foil. We describe here the elements of the apparatus and present the results of test measurements which illustrate its performance.

  18. CT study in primary low spinal fluid pressure syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Moritoshi; Okayama, Kenji; Kubo, Hiromasa; Watanabe, Hiromi; Endou, Riuko (Ohmiya Red Cross Hospital, Yono, Saitama (Japan))

    1991-02-01

    CT findings in primary low spinal fluid pressure syndrome were studied on the basis of 3 cases. Case 1 was a 43-year-old male with a complicated bilateral isodense subdural hematoma (SDH). Case 2 was a 45-year-old female with a complicated bilateral high dense SDH. Case 3 was a 36-year-old female discharged without any complications after spinal fluid pressure normalized. Slight downward displacement of the brain under low spinal fluid pressure was shown as the narrowing of a Sylvian fissures and infratentorial cisterns on CT. On the other hand, in this syndrome with a complicated bilateral isodense SDH, in addition to this finding, CT revealed distortion and narrowing of body lateral ventricles, which might be differential findings from this syndrome without complicated SDH. Under low spinal fluid pressure, bridging veins are more stretched by a downward displacement of the brain. And consequently they were easily injured and SDH was developed. (author).

  19. Low cost sonoluminescence experiment in pressurized water

    Energy Technology Data Exchange (ETDEWEB)

    Bernal, L; Insabella, M [LADOP, University of Mar del Plata (Argentina); Bilbao, L [INFIP, University of Buenos Aires and CONICET (Argentina)

    2012-06-19

    We present a low cost design for demostration and mesurements of light emission from a sonoluminescence experiment. Using pressurized water introduced in an acrylic cylinder and one piezoelectric from an ultrasonic cleaner, we are able to generate cavitacion zones with emission of light. The use of argon to pressurize the water improves the emission an the light can be seen at naked eye in a softlit ambient.

  20. Low cost sonoluminescence experiment in pressurized water

    International Nuclear Information System (INIS)

    Bernal, L; Insabella, M; Bilbao, L

    2012-01-01

    We present a low cost design for demostration and mesurements of light emission from a sonoluminescence experiment. Using pressurized water introduced in an acrylic cylinder and one piezoelectric from an ultrasonic cleaner, we are able to generate cavitacion zones with emission of light. The use of argon to pressurize the water improves the emission an the light can be seen at naked eye in a softlit ambient.

  1. CFD simulation of subcooled flow boiling at low pressure

    International Nuclear Information System (INIS)

    Koncar, B.; Mavko, B.

    2001-01-01

    An increased interest to numerically simulate the subcooled flow boiling at low pressures (1 to 10 bar) has been aroused in recent years, pursued by the need to perform safety analyses of research nuclear reactors and to investigate the sump cooling concept for future light water reactors. In this paper the subcooled flow boiling has been simulated with a multidimensional two-fluid model used in a CFX-4.3 computational fluid dynamics (CFD) code. The existing model was adequately modified for low pressure conditions. It was shown that interfacial forces, which are usually used for adiabatic flows, need to be modeled to simulate subcooled boiling at low pressure conditions. Simulation results are compared against published experimental data [1] and agree well with experiments.(author)

  2. Low Proportion of Dietary Plant Protein among Athletes with Premenstrual Syndrome-Related Performance Impairment.

    Science.gov (United States)

    Yamada, Keiko; Takeda, Takashi

    2018-02-01

    Premenstrual syndrome (PMS) is psychosomatic disorder that are limited to the late luteal phase in the menstrual cycle. PMS could impair athletic performance. To investigate associations between proportions of dietary plant and animal protein and PMS-related impairment of athletic performance, we surveyed 135 female athletes aged 18-23 years attending Kindai University. Participants belonged to authorized university clubs, all of which have high rankings in Japanese university sports. Participants completed self-administered questionnaires on diet history, demographics, and PMS-related impairment of athletic performance. Total protein, animal protein, and plant protein intake were examined, and the proportion of dietary plant protein was calculated for each participant. We divided athletes into two groups: those without PMS-related impairment of athletic performance (n = 117) and those with PMS-related performance impairment (n = 18). A t-test was used to compare mean values and multivariable adjusted mean values between groups; adjustment variables were energy intake, body mass index, and daily training duration. Total protein intake was not significantly different between the groups. However, athletes whose performance was affected by PMS reported higher intake of animal protein (mean 50.6 g) than athletes whose performance was unaffected by PMS (mean 34.9 g). Plant protein intake was lower among athletes with PMS-related impairment (mean 25.4 g) than among athletes without impairment (mean 26.9 g). The proportion of dietary plant protein was lower among athletes with PMS-related impairment (39.3%) than those without impairment (45.9%). A low proportion of dietary plant protein may cause PMS-related athletic impairment among athletes.

  3. A comprehensive study of rate capability in Multi-Wire Proportional Chambers

    International Nuclear Information System (INIS)

    Andronic, A; Garabatos, C; Gonzalez-Diaz, D; Kalweit, A; Uhlig, F

    2009-01-01

    Systematic measurements on the rate capability of thin MWPCs operated in Xenon, Argon and Neon mixtures using CO 2 as UV-quencher are presented. A good agreement between data and existing models has been found, allowing us to present the rate capability of MWPCs in a comprehensive way and ultimately connect it with the mobilities of the drifting ions.

  4. High pressure neutron and X-ray diffraction at low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Ridley, Christopher J.; Kamenev, Konstantin V. [Edinburgh Univ. (United Kingdom). School of Engineering and the Centre for Science at Extreme Conditions

    2014-04-01

    This paper presents a review of techniques and considerations in the design and construction of high pressure, low temperature diffraction experiments. Also intended as an introductory text to new high pressure users, the crucial aspects of pressure cell design are covered. The general classification of common designs, and a discussion into the key beam interaction, mechanical, and thermal properties of commonly used materials is given. The advantages of different materials and high pressure cell classifications are discussed, and examples of designs developed for low temperature diffraction studies are presented, and compared. (orig.)

  5. High pressure neutron and X-ray diffraction at low temperatures

    International Nuclear Information System (INIS)

    Ridley, Christopher J.; Kamenev, Konstantin V.

    2014-01-01

    This paper presents a review of techniques and considerations in the design and construction of high pressure, low temperature diffraction experiments. Also intended as an introductory text to new high pressure users, the crucial aspects of pressure cell design are covered. The general classification of common designs, and a discussion into the key beam interaction, mechanical, and thermal properties of commonly used materials is given. The advantages of different materials and high pressure cell classifications are discussed, and examples of designs developed for low temperature diffraction studies are presented, and compared. (orig.)

  6. Negative-pressure and low-pressure hydrocephalus: the role of cerebrospinal fluid leaks resulting from surgical approaches to the cranial base.

    Science.gov (United States)

    Filippidis, Aristotelis S; Kalani, M Yashar S; Nakaji, Peter; Rekate, Harold L

    2011-11-01

    Negative-pressure and low-pressure hydrocephalus are rare clinical entities that are frequently misdiagnosed. They are characterized by recurrent episodes of shunt failure because the intracranial pressure is lower than the opening pressure of the valve. In this report the authors discuss iatrogenic CSF leaks as a cause of low- or negative-pressure hydrocephalus after approaches to the cranial base. The authors retrospectively reviewed cases of low-pressure or negative-pressure hydrocephalus presenting after cranial approaches complicated with a CSF leak at their institution. Three patients were identified. Symptoms of high intracranial pressure and ventriculomegaly were present, although the measured pressures were low or negative. A blocked communication between the ventricles and the subarachnoid space was documented in 2 of the cases and presumed in the third. Shunt revisions failed repeatedly. In all cases, temporary clinical and radiographic improvement resulted from external ventricular drainage at subatmospheric pressures. The CSF leaks were sealed and CSF communication was reestablished operatively. In 1 case, neck wrapping was used with temporary success. Negative-pressure or low-pressure hydrocephalus associated with CSF leaks, especially after cranial base approaches, is difficult to treat. The solution often requires the utilization of subatmospheric external ventricular drains to establish a lower ventricular drainage pressure than the drainage pressure created in the subarachnoid space, where the pressure is artificially lowered by the CSF leak. Treatment involves correction of the CSF leak, neck wrapping to increase brain turgor and allow the pressure in the ventricles to rise to the level of the opening pressure of the valve, and reestablishing the CSF route.

  7. An Optimal Allocation Model of Public Transit Mode Proportion for the Low-Carbon Transportation

    Directory of Open Access Journals (Sweden)

    Linjun Lu

    2015-01-01

    Full Text Available Public transit has been widely recognized as a potential way to develop low-carbon transportation. In this paper, an optimal allocation model of public transit mode proportion (MPMP has been built to achieve the low-carbon public transit. Optimal ratios of passenger traffic for rail, bus, and taxi are derived by running the model using typical data. With different values of traffic demand, construction cost, travel time, and accessibilities, MPMP can generate corresponding optimal ratios, benefiting decision impacts analysis and decision makers. Instead of considering public transit as a united system, it is separated into units in this paper. And Shanghai is used to test model validity and practicality.

  8. Investigations into low pressure methanol synthesis

    DEFF Research Database (Denmark)

    Sharafutdinov, Irek

    The central topic of this work has been synthesis, characterization and optimization of novel Ni-Ga based catalysts for hydrogenation of CO2 to methanol. The overall goal was to search for materials that could be used as a low temperature (and low pressure) methanol synthesis catalyst....... This is required for small scale delocalized methanol production sites, where installation of energy demanding compression units should be avoided. The work was triggered by DFT calculations, which showed that certain bimetallic systems are active towards methanol synthesis from CO2 and H2 at ambient pressure...... containing 5:3 molar ratio of Ni:Ga, the intrinsic activity (methanol production rate per active surface area) is comparable to that of highly optimised Cu/ZnO/Al2O3. Formation of the catalyst was investigated with the aid of in-situ XRD and in-situ XAS techniques. The mechanism of alloying was proposed...

  9. [Pressure support ventilation and proportional assist ventilation during weaning from mechanical ventilation].

    Science.gov (United States)

    Aguirre-Bermeo, H; Bottiroli, M; Italiano, S; Roche-Campo, F; Santos, J A; Alonso, M; Mancebo, J

    2014-01-01

    To compare tolerance, duration of mechanical ventilation (MV) and clinical outcomes during weaning from MV in patients subjected to either pressure support ventilation (PSV) or proportional assist ventilation (PAV). A prospective, observational study was carried out. Intensive Care Unit. A total of 40 consecutive subjects were allocated to either the PSV or the PAV group until each group contained 20 patients. Patients were included in the study when they met the criteria to begin weaning and the attending physician decided to initiate the weaning process. The physician selected the modality and set the ventilatory parameters. None. Demographic data, respiratory mechanics, ventilatory parameters, duration of MV, and clinical outcomes (reintubation, tracheostomy, mortality). Baseline characteristics were similar in both groups. No significant differences were observed between the PSV and PAV groups in terms of the total duration of MV (10 [5-18] vs. 9 [7-19] days; P=.85), reintubation (5 [31%] vs. 3 [19%]; P=.69), or mortality (4 [20%] vs. 5 [25%] deaths; P=1). Eight patients (40%) in the PSV group and 6 patients (30%) in the PAV group (P=.74) required a return to volume assist-control ventilation due to clinical deterioration. Tolerance, duration of MV and clinical outcomes during weaning from mechanical ventilation were similar in PSV and PAV. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  10. Low-level wind response to mesoscale pressure systems

    Science.gov (United States)

    Garratt, J. R.; Physick, W. L.

    1983-09-01

    Observations are presented which show a strong correlation between low-level wind behaviour (e.g., rotation near the surface) and the passage of mesoscale pressure systems. The latter are associated with frontal transition zones, are dominated by a pressure-jump line and a mesoscale high pressure area, and produce locally large horizontal pressure gradients. The wind observations are simulated by specifying a time sequence of perturbation pressure gradient and subsequently solving the vertically-integrated momentum equations with appropriate initial conditions. Very good agreement is found between observed and calculated winds; in particular, (i) a 360 ° rotation in wind on passage of the mesoscale high; (ii) wind-shift lines produced dynamically by the pressure-jump line; (iii) rapid linear increase in wind speed on passage of the pressure jump.

  11. A system to control low pressure turbine temperatures

    International Nuclear Information System (INIS)

    1980-01-01

    An improved system to control low pressure turbine cycle steam and metal temperatures by governing the heat transfer operation in a moisture separator-reheater is described. The use of the present invention in a pressurized water reactor or a boiling water reactor steam turbine system is demonstrated. (UK)

  12. Bulk characterization of pharmaceutical powders by low-pressure compression II

    DEFF Research Database (Denmark)

    Hagsten Sørensen, A.; Sonnergaard, Jørn; Hovgaard, L.

    2006-01-01

    The aim of the present study was to investigate the effect of punch and die diameter, sample size, compression speed, and particle size on two low-pressure compression-derived parameters; the compressed density and the Walker w parameter. The excellent repeatability of the low-pressure compressio...

  13. Epidural blood patch for refractory low CSF pressure headache

    DEFF Research Database (Denmark)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication...... of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our......Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists...

  14. Epidural blood patch for refractory low CSF pressure headache

    DEFF Research Database (Denmark)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our......Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists...... primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication...

  15. Low vs Standard Pressures in Gynecologic Laparoscopy: a Systematic Review.

    Science.gov (United States)

    Kyle, Esther B; Maheux-Lacroix, Sarah; Boutin, Amélie; Laberge, Philippe Y; Lemyre, Madeleine

    2016-01-01

    The optimal intraperitoneal pressure during laparoscopy is not known. Recent literature found benefits of using lower pressures, but the safety of doing abdominal surgery with low peritoneal pressures needs to be assessed. This systematic review compares low with standard pneumoperitoneum during gynecologic laparoscopy. We searched Medline, Embase, and the Cochrane Library for randomized controlled trials comparing intraperitoneal pressures during gynecologic laparoscopy. Two authors reviewed references and extracted data from included trials. Risk ratios, mean differences, and standard mean differences were calculated and pooled using RevMan5. Of 2251 studies identified, three were included in the systematic review, for a total of 238 patients. We found a statistically significant but modest diminution in postoperative pain of 0.38 standardized unit based on an original 10-point scale (95% confidence interval [CI], -0.67 to -0.08) during the immediate postoperative period when using low intraperitoneal pressure of 8 mm Hg compared with ≥ 12 mm Hg and of 0.50 (95% CI, -0.80 to -0.21) 24 hours after the surgery. Lower pressures were associated with worse visualization of the surgical field (risk ratio, 10.31; 95% CI, 1.29-82.38). We found no difference between groups over blood loss, duration of surgery, hospital length of stay, or the need for increased pressure. Low intraperitoneal pressures during gynecologic laparoscopy cannot be recommended on the behalf of this review because improvement in pain scores is minimal and visualization of the surgical field is affected. The safety of this intervention as well as cost-effectiveness considerations need to be further studied.

  16. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R. M.; Aalseth, C. E.; Day, A. R.; Hoppe, E. W.; Mace, E. K.; Moran, J. J.; Overman, C. T.; Panisko, M. E.; Seifert, A.

    2016-03-01

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium counting efficiency while minimizing radiocarbon beta decay interference.

  17. Negative Ions in low pressure discharges

    NARCIS (Netherlands)

    Stoffels - Adamowicz, E.; Stoffels, W.W.; Vender, D.; Haverlag, M.; Kroesen, G.M.W.; Hoog, de F.J.

    1995-01-01

    Several aspects of negative ions in low pressure discharges are treated. The elementary processes, in which negative ions are produced and destroyed, are summarized. The influence of negative ions on plasma operation is analyzed in terms of transport equations. It is shown that diffusion, electric

  18. Twenty-Four-Hour Central Pulse Pressure for Cardiovascular Events Prediction in a Low-Cardiovascular-Risk Population: Results From the Bordeaux Cohort.

    Science.gov (United States)

    Cremer, Antoine; Boulestreau, Romain; Gaillard, Prune; Lainé, Marion; Papaioannou, Georgios; Gosse, Philippe

    2018-02-23

    Central blood pressure (BP) is a promising marker to identify subjects with higher cardiovascular risk than expected by traditional risk factors. Significant results have been obtained in populations with high cardiovascular risk, but little is known about low-cardiovascular-risk patients, although the differences between central and peripheral BP (amplification) are usually greater in this population. The study aim was to evaluate central BP over 24 hours for cardiovascular event prediction in hypertensive subjects with low cardiovascular risk. Peripheral and central BPs were recorded during clinical visits and over 24 hours in hypertensive patients with low cardiovascular risk (Systematic Coronary Risk Evaluation ≤5%). Our primary end point is the occurrence of a cardiovascular event during follow-up. To assess the potential interest in central pulse pressure over 24 hours, we performed Cox proportional hazard models analysis and comparison of area under the curves using the contrast test for peripheral and central BP. A cohort of 703 hypertensive subjects from Bordeaux were included. After the first 24 hours of BP measurement, the subjects were then followed up for an average of 112.5±70 months. We recorded 65 cardiovascular events during follow-up. Amplification was found to be significantly associated with cardiovascular events when added to peripheral 24-hour pulse pressure ( P =0.0259). The area under the curve of 24-hour central pulse pressure is significantly more important than area under the curve of office BP ( P =0.0296), and there is a trend of superiority with the area under the curve of peripheral 24-hour pulse pressure. Central pulse pressure over 24 hours improves the prediction of cardiovascular events for hypertensive patients with low cardiovascular risk compared to peripheral pulse pressure. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  19. Contingency proportion systematically influences contingency learning.

    Science.gov (United States)

    Forrin, Noah D; MacLeod, Colin M

    2018-01-01

    In the color-word contingency learning paradigm, each word appears more often in one color (high contingency) than in the other colors (low contingency). Shortly after beginning the task, color identification responses become faster on the high-contingency trials than on the low-contingency trials-the contingency learning effect. Across five groups, we varied the high-contingency proportion in 10% steps, from 80% to 40%. The size of the contingency learning effect was positively related to high-contingency proportion, with the effect disappearing when high contingency was reduced to 40%. At the two highest contingency proportions, the magnitude of the effect increased over trials, the pattern suggesting that there was an increasing cost for the low-contingency trials rather than an increasing benefit for the high-contingency trials. Overall, the results fit a modified version of Schmidt's (2013, Acta Psychologica, 142, 119-126) parallel episodic processing account in which prior trial instances are routinely retrieved from memory and influence current trial performance.

  20. A study of an optimal technological solution for the electronics of particle position sensitive gas detectors (multiwire proportional chambers)

    International Nuclear Information System (INIS)

    Zojceski, Z.

    1997-01-01

    This work aims at optimizing the electronics for position sensitive gas detectors. The first part is a review of proportional chamber operation principles and presents the different possibilities for the architecture of the electronics. The second part involves electronic signal processing for best signal-to-noise ratio. We present a time-variant filter based on a second order base line restorer.It allows a simple pole-zero and tail cancellation at high counting rates. Also, various interpolating algorithms for cathode strip chambers have been studied. The last part reports the development of a complete electronic system, from the preamplifiers up to the readout and control interface, for the cathode strip chambers in the focal plane of the BBS Spectrometer at KVI, Holland. The system is based on application specific D-size VXI modules. In all modules, the 16-bit ADCs and FIFO memory are followed by a Digital Signal Processor, which performs data filtering and cathode induced charge interpolation. Very good analog noise performance is obtained in a multi-processor environment. (author)

  1. Determination of 241Pu by low level β-proportional counting

    International Nuclear Information System (INIS)

    Rosner, G.; Hoetzl, H.; Winkler, R.

    1992-01-01

    A chemical separation procedure is described which allows the direct determination of low 241 Pu activities in environmental samples with a windowless gas-flow proportional counter. While current separation schemes based on anion exchange yield counting sources of sufficient purity for subsequent α-spectrometry, for β-counting of 241 Pu additional purification steps are required. A combination of anion exchange from 9 mol/1 HCl, LaF 3 precipitation and TTA extraction was found to be suitable even for analysis of long-range Chernobyl fallout samples which contained interfering radionuclides with β-activities at least 3 to 4 orders of magnitude higher than usually encountered. No difference is detectable between the results of the present, direct procedure and the results of the conventional indirect method based on the build-up of 241 Am. Average 241 Pu/ 239+241 Pu ratios in air and deposition samples taken at Neuherberg near Munich were 70±6 with the present procedure and 66±9 from 241 Am build-up. (author) 29 refs.; 3 tabs

  2. Detectors: Electronic detectors in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1990-03-15

    Twenty years ago, the development by Georges Charpak's group at CERN of the multiwire proportional chamber and the drift chamber revolutionized particle detection, bringing substantial improvements in accuracy and response.

  3. Improvement of efficiency by proportional and integral control for compact boiler; Shoyoryo boiler no renzoku seigyo (P.I seigyo) ni yoru seino kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, T. [Kawasaki Thermal Engineering Co. Ltd., Shiga (Japan)

    1998-10-01

    Efficiency of a compact boiler is improved by the introduction of a continuous P.I. control. It is controlled by the following procedure. The proportional control, which controls magnitude of combustion in proportion to a load requirement, is combined with an integral control function which keeps steam pressure at a given level, in order to stabilize steam pressure at a level comparable to that of a large, water-tube type boiler. A stable steam pressure is realized by including control of make-up water supply, to minimize the effects of water supply on steam pressure. The effects of characteristics of the combustion valve on control are relaxed by programming. In addition to the above, rotational speed of the motor for the forced draft fan is controlled for each load level, to reduce power consumption. These bring improved quality of steam, i.e., stabilized steam pressure, improved follow-up characteristics of the steam and secured dryness of the steam. Energy-saving is also achieved, i.e., reduction of noise and power consumption at a low combustion load are achieved by improved real boiler efficiency and inverter-aided control of the forced draft fan. Low-NOx burners are adopted, to abate NOx content to 60ppm or less at any load. 16 figs.

  4. In honour of Charpak

    CERN Multimedia

    2009-01-01

    More than 40 years ago, Georges Charpak invented the multi-wire proportional chamber, which revolutionized the detection of particles and found applications in medicine. On 9 March, there will be a conference here at CERN to celebrate Georges Charpak’s 85th birthday and to pay tribute to his groundbreaking work. After an introduction by Rolf Heuer, CERN Director-General, Georges Charpak will give a short speech by videoconference. This will be followed by a talk on the invention of the multi-wire proportional chamber by Ioanis Giomataris of CEA-Saclay. You are invited to attend this special conference in the Main Auditorium, from 4.00 pm to 6.00 pm: http://indico.cern.ch/conferenceDisplay.py?confId=53188

  5. A primary scintillation gated high pressure position sensitive gas scintillation proportional counter (HPGSPC) for applications to x-ray astronomy

    International Nuclear Information System (INIS)

    Giarrusso, S.; Manzo, G.; Re, S.

    1985-01-01

    The authors describe a new instrument for x-ray astronomy. The instrument, based on a high pressure (5 atm.), xenon filled, position sensitive Gas Scintillation Proportional counter (HPGSPC) is expected to feature an energy resolution better than 4% at 60 keV, an angular resolution of approximately 20 arc-minutes over the full energy range (4 to 100 keV) and a field of view (FOV) of up to 30x30 degrees. A prototype flight unit of the gas cell on which the instrument is based is presently under technological development in the framework of the SAX project

  6. Blood pressure response to low level static contractions

    DEFF Research Database (Denmark)

    Fallentin, Nils; Jørgensen, Kurt

    1992-01-01

    The present study re-examines the 15% MVC concept, i.e. the existence of a circulatory steady-state in low intensity static contractions below 15% of maximal voluntary contraction (MVC). Mean arterial blood pressure was studied during static endurance contractions of the elbow flexor and extensor...... 0.7) min for elbow extension]. Mean arterial blood pressure exhibited a continuous and progressive increase during the 10% MVC contractions indicating that the 15% MVC concept would not appear to be valid. The terminal blood pressure value recorded at the point of exhaustion in the 10% MVC elbow...... the circulation to the muscles was arrested just prior to the cessation of the contraction, blood pressure only partly recovered and remained elevated for as long as the occlusion persisted, indicating the level of pressure-raising muscle chemoreflexes. Based on blood pressure recordings obtained during...

  7. Low pressure microenvironments: Methane production at 50 mbar and 100 mbar by methanogens

    Science.gov (United States)

    Mickol, Rebecca L.; Kral, Timothy A.

    2018-04-01

    Low pressure is often overlooked in terms of possible biocidal effects when considering a habitable environment on Mars. Few experiments have investigated the ability for microorganisms to actively grow under low pressure conditions, despite the atmosphere being a location on Earth where organisms could be exposed to these pressures. Three species of methanogens (Methanobacterium formicicum, Methanosarcina barkeri, Methanococcus maripaludis) were tested for their ability to actively grow (demonstrate an increase in methane production and optical density) within low-pressure microenvironments at 50 mbar or 100 mbar. M. formicicum was the only species to demonstrate both an increase in methane and an increase in optical density during the low-pressure exposure period for experiments conducted at 50 mbar and 100 mbar. In certain experiments, M. barkeri showed an increase in optical density during the low-pressure exposure period, likely due to the formation of multicellular aggregates, but minimal methane production (conditions. Results indicate that low pressure exposure may just be inhibitory during the exposure itself, and metabolism may resume following incubation under more ideal conditions. Further work is needed to address growth/survival under Mars surface pressures.

  8. Observation of hard X-rays line emission from Her X-1

    Energy Technology Data Exchange (ETDEWEB)

    Polcaro, V.F.; Bazzano, A.; la Padula, C.; Ubertini, P.; Vialetto, G.; Manchanda, R.K.; Damle, S.V.

    1982-04-01

    We present the results of a hard X-ray measurement of the binary source Her X-1, carried out with a balloon borne X-ray telescope consisting of two Multiwire Proportional Counters, having 900 cm/sup 2/ sensitive area each and spectral resolution of 15% and 24% FWHM respectively at 60 keV. The source was observed during the 'Mid-on' state. Our data confirm the previously reported high energy emission line overimposed on the low energy thermal spectrum.

  9. Development of a low-level radon reference chamber; Entwicklung einer Low-Level-Radon-Referenzkammer

    Energy Technology Data Exchange (ETDEWEB)

    Linzmaier, Diana

    2013-01-04

    The naturally occurring, radioactive noble gas radon-222 exists worldwide in different activity concentrations in the air. During the decay of radon-222, decay products are generated which are electrically charged and attach to aerosols in the air. Together with the aerosols, the radon is inhaled and exhaled by humans. While the radon is nearly completely exhaled, ca. 20 % of the inhaled aerosols remain in the lungs in one breath cycle. Due to ionizing radiation, in a chain of events, lung cancer might occur. Consequently, radon and its decay products are according to the current findings the second leading cause of lung cancer. At the workplace and in the home measurements of radon activity concentration are performed to determine the radiation exposition of humans. All measurement devices for the determination of radon activity concentration are calibrated above 1000 Bq/m{sup 3}, even though the mean value of the present investigation in Germany shows only 50 Bq/m{sup 3}. For the calibration of measurement devices in the range below 1000 Bq/m{sup 3} over a long time period, the generation of a stable reference atmosphere is presented in this work. Due to a long term calibration (t>5 days) of the measurement devices, smaller uncertainties result for the calibration factor. For the calibration procedure, a so-called low-level radon reference chamber was set up and started operation. The generation of a stable reference atmosphere is effected by means of emanation sources which consist of a radium-226 activity standard. On the basis of {gamma}-spectrometry, the effective emanation coefficient ofthe emanation sources is determined. The traceability of the activity concentration in the reference volume is realized via the activity ofthe radium-226, the emanation coefficient and the volume. With the emanation sources produced, stable reference atmospheres within the range of 150 Bq/m{sup 3} to 1900 Bq/m{sup 3} are achieved. For the realization, maintenance and

  10. Effects of long-term low atmospheric pressure on gas exchange and growth of lettuce

    Science.gov (United States)

    Tang, Yongkang; Guo, Shuangsheng; Dong, Wenping; Qin, Lifeng; Ai, Weidang; Lin, Shan

    2010-09-01

    The objectives of this research were to determine photosynthesis, evapotranspiration and growth of lettuce at long-term low atmospheric pressure. Lettuce ( Lactuca sativa L . cv. Youmaicai) plants were grown at 40 kPa total pressure (8.4 kPa p) or 101 kPa total pressure (20.9 kPa p) from seed to harvest for 35 days. Germination rate of lettuce seeds decreased by 7.6% at low pressure, although this was not significant. There was no significant difference in crop photosynthetic rate between hypobaria and ambient pressure during the 35-day study. The crop evapotranspiration rate was significantly lower at low pressure than that at ambient pressure from 20 to 30 days after planting (DAP), but it had no significant difference before 20 DAP or after 30 DAP. The growth cycle of lettuce plants at low pressure was delayed. At low pressure, lettuce leaves were curly at the seedling stage and this disappeared gradually as the plants grew. Ambient lettuce plants were yellow and had an epinastic growth at harvest. The shoot height, leaf number, leaf length and shoot/root ratio were lower at low pressure than those at ambient pressure, while leaf area and root growth increased. Total biomass of lettuce plants grown at two pressures had no significant difference. Ethylene production at low pressure decreased significantly by 38.8% compared with ambient pressure. There was no significant difference in microelements, nutritional phytochemicals and nitrate concentrations at the two treatments. This research shows that lettuce can be grown at long-term low pressure (40 kPa) without significant adverse effects on seed germination, gas exchange and plant growth. Furthermore, ethylene release was reduced in hypobaria.

  11. Carbon resistor pressure gauge calibration at low stresses

    International Nuclear Information System (INIS)

    Cunningham, Bruce; Vandersall, Kevin S.; Niles, Angela M.; Greenwood, Daniel W.; Garcia, Frank; Forbes, Jerry W.; Wilson, William H.

    2002-01-01

    The 470 Ohm carbon resistor gauge has been used in the stress range up to 4-5 GPa for highly heterogeneous materials and/or divergent flow experiments. The attractiveness of the gauge is its rugged nature, simple construction, low cost, reproducibility, and survivability in dynamic events. Gauge drawbacks are the long time response to pressure equilibration and gauge resistance hysteresis. In the regime below 0.4 GPa, gauge calibration has been extrapolated. Because of the need for calibration data within this low stress regime, calibration experiments were performed using a split-Hopkinson bar, drop tower apparatus, and gas pressure chamber. Since the performance of the gauge at elevated temperatures is a concern, the change in resistance due to heating at atmospheric pressure was also investigated. Details of the various calibration arrangements and the results are discussed and compared to a calibration curve fit to previously published calibration data

  12. Study of SmS properties in the low pressure phase (black phase)

    International Nuclear Information System (INIS)

    Bordier, G.

    1986-01-01

    SmS was studied for the transition from low pressure phase (black phase) to high pressure phase with an intermediate valence. But the study of the black phase is very rich. The variations of electron transport properties with pressure at low temperature show a semi-metal phase located, in the pressure-temperature diagram in the black phase for pressure over 4 kbars, corresponding to the phase B'of the doping-temperature diagram. Electron spin resonance shows a lack of sulfur and nearby this defect a samarium ion, magnetically coupled with the matrix, presents a divalent trivalent transition. Resonance lines are broadened with temperature. Conductivity relaxations occur at low pressure and low temperature by trapping a conduction electron, by magnetic exchange giving a bounded magnetic polaron. The relaxation time at null magnetic field is activated. An approximation of trapping barrier and critical field corresponding the maximum magnetoresistance is given by a model [fr

  13. Use of tissue equivalent proportional counters to characterize radiation quality on the space shuttle

    International Nuclear Information System (INIS)

    Braby, L.A.; Conroy, T.J.; Elegy, D.C.; Brackenbush, L.W.

    1992-04-01

    Tissue equivalent proportional counters (TEPC) are essentially cavity ionization chambers operating at low pressure and with gas gain. A small, battery powered, TEPC spectrometer, which records lineal energy spectra at one minute intervals, has been used on several space shuttle missions. The data it has collected clearly show the South Atlantic anomaly and indicate a mean quality factor somewhat higher than expected. An improved type of instrument has been developed with sufficient memory to record spectra at 10 second intervals, and with increased resolution for low LET events. This type of instrument will be used on most future space shuttle flights and in some international experiments

  14. Turbine airfoil cooling system with cooling systems using high and low pressure cooling fluids

    Science.gov (United States)

    Marsh, Jan H.; Messmann, Stephen John; Scribner, Carmen Andrew

    2017-10-25

    A turbine airfoil cooling system including a low pressure cooling system and a high pressure cooling system for a turbine airfoil of a gas turbine engine is disclosed. In at least one embodiment, the low pressure cooling system may be an ambient air cooling system, and the high pressure cooling system may be a compressor bleed air cooling system. In at least one embodiment, the compressor bleed air cooling system in communication with a high pressure subsystem that may be a snubber cooling system positioned within a snubber. A delivery system including a movable air supply tube may be used to separate the low and high pressure cooling subsystems. The delivery system may enable high pressure cooling air to be passed to the snubber cooling system separate from low pressure cooling fluid supplied by the low pressure cooling system to other portions of the turbine airfoil cooling system.

  15. A new gamma camera for positron emission tomography

    International Nuclear Information System (INIS)

    Schotanus, P.

    1988-01-01

    This thesis describes the detection of annihiliation radiation employing a new principle: radiation is absorbed in a barium fluoride (BaF 2) crystal and the resulting scintillation light is detected in a multiwire proportional chamber filled with a photsensitive vapour. The application of such a detector for PET is new; the use of a high density fast scintillator in combination with a low pressure wire chamber offers a good detection efficiency and permits high count rates because of the small dead time. In this work, the physical background of the above detection mechanism is explored and the performance parameters of a gamma camera using this new principle, are determined. Furthermore, a comprehensive research on the scintillation mechanism and physical characteristics of the increasingly popular BaF 2 scintillator is presented. Also, a new class of ultraviolet (UV) scintillation materials, consisting of rare earth doped fluorides, is introduced. (author). 211 refs.; 30 figs.; 17 tabs

  16. MODEL TESTING OF LOW PRESSURE HYDRAULIC TURBINE WITH HIGHER EFFICIENCY

    Directory of Open Access Journals (Sweden)

    V. K. Nedbalsky

    2007-01-01

    Full Text Available A design of low pressure turbine has been developed and it is covered by an invention patent and a useful model patent. Testing of the hydraulic turbine model has been carried out when it was installed on a vertical shaft. The efficiency was equal to 76–78 % that exceeds efficiency of the known low pressure blade turbines. 

  17. Evaluation of a mindfulness-based intervention program to decrease blood pressure in low-income African-American older adults.

    Science.gov (United States)

    Palta, Priya; Page, G; Piferi, R L; Gill, J M; Hayat, M J; Connolly, A B; Szanton, S L

    2012-04-01

    Hypertension affects a large proportion of urban African-American older adults.While there have been great strides in drug development, many older adults do not have access to such medicines or do not take them. Mindfulness-based stress reduction (MBSR)has been shown to decrease blood pressure in some populations. This has not been tested in low-income, urban African-American older adults. Therefore, the primary purpose of this pilot study was to test the feasibility and acceptability of a mindfulness-based program for low income, minority older adults provided in residence. The secondary purpose was to learn if the mindfulness-based program produced differences in blood pressure between the intervention and control groups. Participants were at least 62 years old and residents of a low-income senior residence. All participants were African-American, and one was male.Twenty participants were randomized to the mindfulness-based intervention or a social support control group of the same duration and dose. Blood pressure was measured with the Omron automatic blood pressure machine at baseline and at the end of the 8-week intervention. A multivariate regression analysis was performed on the difference in scores between baseline and post-intervention blood pressure measurements, controlling for age,education, smoking status, and anti-hypertensive medication use. Effect sizes were calculated to quantify the magnitude of the relationship between participation in the mindfulness-based intervention and the outcome variable, blood pressure. Attendance remained 980%in all 8 weeks of both the intervention and the control groups. The average systolic blood pressure decreased for both groups post-intervention. Individuals in the intervention group exhibited a 21.92-mmHg lower systolic blood pressure compared to the social support control group post-intervention and this value was statistically significant(p=0.020). The average diastolic blood pressure decreased in the

  18. Low Power and High Sensitivity MOSFET-Based Pressure Sensor

    International Nuclear Information System (INIS)

    Zhang Zhao-Hua; Ren Tian-Ling; Zhang Yan-Hong; Han Rui-Rui; Liu Li-Tian

    2012-01-01

    Based on the metal-oxide-semiconductor field effect transistor (MOSFET) stress sensitive phenomenon, a low power MOSFET pressure sensor is proposed. Compared with the traditional piezoresistive pressure sensor, the present pressure sensor displays high performances on sensitivity and power consumption. The sensitivity of the MOSFET sensor is raised by 87%, meanwhile the power consumption is decreased by 20%. (cross-disciplinary physics and related areas of science and technology)

  19. A high count rate one-dimensional position sensitive detector and a data acquisition system for time resolved X-ray scattering studies

    International Nuclear Information System (INIS)

    Pernot, P.

    1982-01-01

    A curved multiwire proportional drift chamber has been built as a general purpose instrument for X-ray scattering and X-ray diffraction experiments with synchrotron radiation. This parallaxe-free one-dimensional linear position sensitive detector has a parallel readout with a double hit logic. The data acquisition system, installed as a part of the D11 camera at LURE-DCI, is designed to perform time slicing and cyclic experiments; it has been used with either the fast multiwire chamber or a standard position sensitive detector with delay line readout [fr

  20. Low Pressure Circuit Control and adjust System Test

    International Nuclear Information System (INIS)

    Rubio, R.O; Brendstrup, C.J; Ocampo, A.C

    2000-01-01

    The hydraulic mechanism (MSAC) is a system that will be employed in the movement of the control rods of the CAREM-25 reactor.In this report, the experimental work on a prototype of MSAC in a low pressure circuit is presented: also the methodology and conclusions.Basic thermalhydraulic data from the MSAC was obtained, and the most relevant control parameters were determined.The response of the mechanism to changes in the control parameters was also evaluated. In conclusion, the response of the MSAC fulfills the aspects of reliability and repetitive movement with water flow pulses control, in the low pressure circuit at the Laboratorio de Mecanica, Materiales y Mediciones of INVAP S.E

  1. Operation of gas electron multiplier (GEM) with propane gas at low pressure and comparison with tissue-equivalent gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    De Nardo, L., E-mail: laura.denardo@unipd.it [University of Padova, Physics and Astronomy Department and PD-INFN, via Marzolo 8, I-35131 Padova (Italy); Farahmand, M., E-mail: majid.farahmand@rivm.nl [Centre for Environmental Safety and Security, National Institute for Public Health and the Environment (RIVM), PO Box 1, NL-3720 BA Bilthoven (Netherlands)

    2016-05-21

    A Tissue-Equivalent Proportional Counter (TEPC), based on a single GEM foil of standard geometry, has been tested with pure propane gas at low pressure, in order to simulate a tissue site of about 1 µm equivalent size. In this work, the performance of GEM with propane gas at a pressure of 21 and 28 kPa will be presented. The effective gas gain was measured in various conditions using a {sup 244}Cm alpha source. The dependence of effective gain on the electric field strength along the GEM channel and in the drift and induction region was investigated. A maximum effective gain of about 5×10{sup 3} has been reached. Results obtained in pure propane gas are compared with gas gain measurements in gas mixtures commonly employed in microdosimetry, that is propane and methane based Tissue-Equivalent gas mixtures.

  2. High pressure apparatus for neutron scattering at low temperature

    International Nuclear Information System (INIS)

    Munakata, Koji; Uwatoko, Yoshiya; Aso, Naofumi

    2010-01-01

    Effects of pressure on the physical properties are very important for understanding highly correlated electron systems, in which pressure-induced attractive phenomena such as superconductivity and magnetically ordered non-Fermi liquid have been observed. Up to now, many scientists have developed a lot of high pressure apparatus for each purpose. The characteristic features of various materials and pressure transmitting media for use of high pressure apparatus are reported. Then, two kinds of clamp type high-pressure cell designed for low-temperature neutron diffraction measurements are shown; one is a piston cylinder type high-pressure cell which can be attached to the dilution refrigerator, and the other one is a newly-developed cubic anvil type high-pressure cell which can generate pressure above 7GPa. We also introduce the results of magnetic neutron scattering under pressure on a pressure-induced superconducting ferromagnet UGe 2 in use of the piston cylinder type clamp cell, and those on an iron arsenide superconductor SrFe 2 As 2 in use of the cubic anvil type clamp cell. (author)

  3. In honour of Georges Charpak

    CERN Multimedia

    More than 40 years ago, Georges Charpak invented the multi-wire proportional chamber, which revolutionized the detection of particles and which found applications in medicine. He was awarded the Nobel Prize in physics for this invention in 1992. On March 9, there will be a conference here at CERN to celebrate Georges Charpak’s 85th birthday and to pay tribute to his groundbreaking work. After an introduction by Rolf Heuer, CERN Director-General, Georges Charpak will give a short speech by videoconference. This will be followed by a talk on the invention of the multi-wire proportional chamber by Ioanis Giomataris of CEA-Saclay. You are invited to attend this special conference in the Main Auditorium, from 4.00 pm to 6.00 pm: http://indico.cern.ch/conferenceDisplay.py?confId=53188

  4. Detection systems for high energy particle producing gaseous ionization

    International Nuclear Information System (INIS)

    Duran, I.; Martinez, L.

    1985-01-01

    This report contains a review on the most used detectors based on the collection of the ionization produced by high energy particles: proportional counters, multiwire proportional chambers, Geiger-Mueller counters and drift chambers. In six sections, the fundamental principles, the field configuration and useful gas mixtures are discussed, most relevant devices are reported. (author)

  5. Analysis of Pressure Variations in a Low-Pressure Nickel-Hydrogen Battery - Part 1.

    Science.gov (United States)

    Purushothaman, B K; Wainright, J S

    2012-05-15

    A low pressure nickel-hydrogen battery using either a metal hydride or gaseous hydrogen for H(2) storage has been developed for use in implantable neuroprosthetic devices. In this paper, pressure variations inside the cell for the gaseous hydrogen version are analyzed and correlated with oxygen evolution side reaction at the end of charging, the recombination of oxygen with hydrogen during charging and a subsequent rest period, and the self-discharge of the nickel electrode. About 70% of the recombination occurred simultaneously with oxygen evolution during charging and the remaining oxygen recombined with hydrogen during the 1(st) hour after charging. Self-discharge of the cell varies linearly with hydrogen pressure at a given state of charge and increased with increasing battery charge levels. The coulometric efficiency calculated based on analysis of the pressure-time data agreed well with the efficiency calculated based on the current-time data. Pressure variations in the battery are simulated accurately to predict coulometric efficiency and the state of charge of the cell, factors of extreme importance for a battery intended for implantation within the human body.

  6. Gain measurements in CO2 CW low pressure lasers

    International Nuclear Information System (INIS)

    Rodrigues, N.A.S.; Chanes Junior, J.B.; Jayaram, K.

    1983-01-01

    A series of gain measurements in low pressure CO 2 CW laser were performed in order to study the behaviour of a CO 2 laser ampliflier as a function of pressure and discharge current. A theoretical model, based on rate equations is also presented to describe the laser behaviour and the experimental procedure adopted. (C.L.B.) [pt

  7. Production and test of the LHCb Muon Chamber

    CERN Multimedia

    2005-01-01

    - The Muon System of LHCb - The Multi-Wire Proportional Chambers for LHCb - Wire tension meter - Wire pitch measurement - Gas leakage test - Test with cosmic rays - Production and test summary - Gap gain uniformity - Production and test summary

  8. Comparison of under-pressure and over-pressure pulse tests conducted in low-permeability basalt horizons at the Hanford Site, Washington State

    International Nuclear Information System (INIS)

    Thorne, P.D.; Spane, F.A. Jr.

    1984-10-01

    Over-pressure pulse tests (pressurized slug tests have been widely used by others for hydraulic characterization of low-permeability ( -8 m/sec) rock formations. Recent field studies of low-permeability basalt horizons at the Hanford Site, Washington, indicate that the under-pressure pulse technique is also a viable test method for hydraulic characterization studies. For over-pressure pulse tests, fluid within the test system is rapidly pressurized and the associated pressure decay is monitored as compressed fluid within the test system expands and flows into the test formation. Under-pressure pulse tests are conducted in a similar manner by abruptly decreasing the pressure of fluid within the test system, and monitoring the associated increase in pressure as fluid flows from the formation into the test system. Both pulse test methods have been used in conjunction with other types of tests to determine the hydraulic properties of selected low-permeability basalt horizons at Hanford test sites. Results from both pulse test methods generally provide comparable estimates of hydraulic properties and are in good agreement with those from other tests

  9. High-pressure powder x-ray diffraction experiments on Zn at low temperature

    CERN Document Server

    Takemura, K; Fujihisa, H; Kikegawa, T

    2002-01-01

    High-pressure powder x-ray diffraction experiments have been performed on Zn with a He-pressure medium at low temperature. When the sample was compressed in the He medium at low temperature, large nonhydrostaticity developed, yielding erroneous lattice parameters. On the other hand, when the pressure was changed at high temperatures, good hydrostaticity was maintained. No anomaly in the volume dependence of the c/a axial ratio has been found.

  10. A new method for decontamination of radioactive waste using low-pressure arc discharge

    International Nuclear Information System (INIS)

    Fujiwara, Kazutoshi; Furukawa, Shizue; Adachi, Kazuo; Amakawa, Tadashi; Kanbe, Hiromi

    2006-01-01

    In this paper, the decontamination features of the low-pressure arc-discharge method for radioactive waste generated in the operation and maintenance of nuclear power plants were examined. The low-pressure arc-discharge method was applied to type 304 stainless-steel, type 316L stainless-steel, alloy 600 and carbon-steel covered with radioactive corrosion products. Approximately, 80% of the radioactivity build up on stainless-steels could be removed by the low-pressure arc discharge

  11. Boron, arsenic and phosphorus dopant incorporation during low temperature low pressure silicon epitaxial growth

    International Nuclear Information System (INIS)

    Borland, J.O.; Thompson, T.; Tagle, V.; Benzing, W.

    1987-01-01

    Submicron silicon epitaxial structures with very abrupt epi/substrate transition widths have been realized through the use of low temperature silicon epitaxial growth techniques. At these low temperature and low pressure epitaxial growth conditions there is minimal, if any, dopant diffusion from the substrate into the epilayer during deposition. The reincorporation of autodoped dopant as well as the incorporation of intentional dopant can be a trade-off at low temperatures and low pressures. For advanced CMOS and Bi-CMOS technologies, five to six orders of magnitude change in concentration levels are desirable. In this investigation, all of the epitaxial depositions were carried out in an AMC-7810 epi-reactor with standard jets for a turbulent mixing system, and using a modified center inject configuration to achieve a single pass laminar flow system. To simulate the reincorporation of various autodoped dopant, the authors ran a controlled dopant flow of 100 sccm for each of the three dopants (boron, phosphorus and arsenic) to achieve the controlled background dopant level in the reactor gas stream

  12. Five-dimensional visualization of phase transition in BiNiO3 under high pressure

    International Nuclear Information System (INIS)

    Liu, Yijin; Wang, Junyue; Yang, Wenge; Azuma, Masaki; Mao, Wendy L.

    2014-01-01

    Colossal negative thermal expansion was recently discovered in BiNiO 3 associated with a low density to high density phase transition under high pressure. The varying proportion of co-existing phases plays a key role in the macroscopic behavior of this material. Here, we utilize a recently developed X-ray Absorption Near Edge Spectroscopy Tomography method and resolve the mixture of high/low pressure phases as a function of pressure at tens of nanometer resolution taking advantage of the charge transfer during the transition. This five-dimensional (X, Y, Z, energy, and pressure) visualization of the phase boundary provides a high resolution method to study the interface dynamics of high/low pressure phase

  13. High performance electrodes for low pressure H{sub 2}-air PEM fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Besse, S; Bronoel, G; Fauvarque, J F [Laboratoires SORAPEC (France)

    1998-12-31

    Proton exchange membrane fuel cells (PEMFCs) were first developed for space applications in the 1960s. Currently, they are being manufactured for terrestrial portable power applications. One of the challenges is to develop a low pressure H{sub 2}/Air PEMFC in order to minimize the cathodic mass transport overpotentials. The hydrogen oxidation reaction is considered to be sufficiently rapid. Hydrogen transport limitations are very low even at high current densities. The different applications considered for hydrogen/air PEMFC need to work at atmospheric pressure. An optimization of the structure of the oxygen electrode and the membrane electrode assembly (MEA) are essential in order to decrease mass transport limitations and to obtain good water management even at low pressures. Efforts have been made to produce electrodes and MEA for PEMFC with low platinum loading. The electrode structure was developed to ensure a good diffusion of reactants and an effective charge collection. It has also been optimized for low pressure restrictions. It was concluded that high performances can be achieved even at low pressures by improving the electrode gas diffusion layer (PTFE content) and by improving the catalyst. 12 refs., 7 figs.

  14. X-ray detectors for diffraction studies and their use with synchrotron radiation

    International Nuclear Information System (INIS)

    Milch, J.

    1976-02-01

    All techniques for X-ray diffraction studies on biological materials exhibit certain limitations. The characteristics of several X-ray detection systems, namely film, multiwire proportional counter and image intensified TV, are discussed and compared for application to specific biological studies. For the high count-rate situation existing at a synchrotron, it is shown that film is a good choice, but that the image intensified TV exhibits significant advantages. The details of such a system now being used at Princeton with a low intensity source are given and current results presented

  15. Design and experiment of high-current low-pressure plasma-cathode e-gun

    International Nuclear Information System (INIS)

    Xie Wenkai; Li Xiaoyun; Wang Bin; Meng Lin; Yan Yang; Gao Xinyan

    2006-01-01

    The preliminary design of a new high-power low pressure plasma-cathode e-gun is presented. Based on the hollow cathode effect and low-pressure glow discharge empirical formulas, the hollow cathode, the accelerating gap, and the working gas pressure region are given. The general experimental device of the low-pressure plasma cathode electron-gun generating high current density e-beam source is shown. Experiments has been done in continuous filled-in gases and gases-puff condition, and the discharging current of 150-200 A, the width of 60 μs and the collector current of 30-80 A, the width of 60 μs are obtained. The results show that the new plasma cathode e-gun can take the place of material cathode e-gun, especially in plasma filled microwave tubes. (authors)

  16. Pressure drops in low pressure local boiling

    International Nuclear Information System (INIS)

    Courtaud, Michel; Schleisiek, Karl

    1969-01-01

    For prediction of flow reduction in nuclear research reactors, it was necessary to establish a correlation giving the pressure drop in subcooled boiling for rectangular channels. Measurements of pressure drop on rectangular channel 60 and 90 cm long and with a coolant gap of 1,8 and 3,6 mm were performed in the following range of parameters. -) 3 < pressure at the outlet < 11 bars abs; -) 25 < inlet temperature < 70 deg. C; -) 200 < heat flux < 700 W/cm 2 . It appeared that the usual parameter, relative length in subcooled boiling, was not sufficient to correlate experimental pressure losses on the subcooled boiling length and that there was a supplementary influence of pressure, heat flux and subcooling. With an a dimensional parameter including these terms a correlation was established with an error band of ±10%. With a computer code it was possible to derive the relation giving the overall pressure drop along the channel and to determine the local gradients of pressure drop. These local gradients were then correlated with the above parameter calculated in local conditions. 95 % of the experimental points were computed with an accuracy of ±10% with this correlation of gradients which can be used for non-uniform heated channels. (authors) [fr

  17. Demand-type gas supply system for rocket borne thin-window proportional counters

    Science.gov (United States)

    Acton, L. W.; Caravalho, R.; Catura, R. C.; Joki, E. G.

    1977-01-01

    A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.

  18. Low pressure powder injection moulding of stainless steel powders

    Energy Technology Data Exchange (ETDEWEB)

    Zampieron, J.V.; Soares, J.P.; Mathias, F.; Rossi, J.L. [Powder Processing Center CCP, Inst. de Pesquisas Energeticas e Nucleares, Sao Paulo, SP (Brazil); Filho, F.A. [IPEN, Inst. de Pesquisas Energeticas e Nucleares, Cidade Univ., Sao Paulo, SP (Brazil)

    2001-07-01

    Low-pressure powder injection moulding was used to obtain AISI 316L stainless steel parts. A rheological study was undertaken using gas-atomised powders and binders. The binders used were based on carnauba wax, paraffin, low density polyethylene and microcrystalline wax. The metal powders were characterised in terms of morphology, particle size distribution and specific surface area. These results were correlated to the rheological behaviour. The mixture was injected in the shape of square bar specimens to evaluate the performance of the injection process in the green state, and after sintering. The parameters such as injection pressure, viscosity and temperature were analysed for process optimisation. The binders were thermally removed in low vacuum with the assistance of alumina powders. Debinding and sintering were performed in a single step. This procedure shortened considerably the debinding and sintering time. (orig.)

  19. Generating of low energy intensive ion streams in conditions of low pressure

    International Nuclear Information System (INIS)

    Zinoviev, D.V.; Tseluyko, A.F.; Chunadra, A.G.; Yunakov, N.N.

    2000-01-01

    In the work the method of forming of low energy ion streams near the sample surface with separating the generation area of plasma and the acceleration area of ion is offered.It allows to lower pressure in acceleration area essentially (0.01 Pa and below).The separating of the areas takes place at the expense of vacuum resistance in a plasma generating device.The dependence of plasma parameters on exterior parameters of the device is determined and the way of the further decreasing of working pressure in the modification area up to 10 -3 - 10 -4 Pa are shown

  20. Search of significant features in a direct non parametric pattern recognition method. Application to the classification of a multiwire spark chamber picture

    International Nuclear Information System (INIS)

    Buccheri, R.; Coffaro, P.; Di Gesu, V.; Salemi, S.; Colomba, G.

    1975-01-01

    Preliminary results are given of the application of a direct non parametric pattern recognition method to the classification of the pictures of a multiwire spark chamber. The method, developed in an earlier work for an optical spark chamber, looks promising. The picture sample used has with respect to the previous one, the following characteristis: a) the event pictures have a more complicated structure; b) the amount of background sparks in an event is greater; c) there exists a kind of noise which is almost always present in some structured way (double sparkling, bursts...). New features have been used to characterize the event pictures; the results show that the method could be also used as a super filter to reduce the cost of further analysis. (Auth.)

  1. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellerman, E.W.; Bateman, J.E.; Connolly, J.F.

    1979-01-01

    The properties of a prototype gas proportional scintillation (GPS) detector module are described. The module (25X25X14cm 3 ) is intended to form the basic unit of large area (up to approximately 100 m 2 ) calorimetric cosmic ray burst detector. Ionisation from particle tracks in the module is collected onto a point electrode where the GPS signal is generated. A concave mirror focusses this point source onto the end of a fibre optic light guide. In the proposed large area detector these fibres are brought together onto a low light level TV camera which performs the readout. The prototype module has demonstrated an adequate light output for the detection of single muons by such a readout system and also permitted the investigation of the main operating parameters (gas mixture, EHT, pressure, etc) and operational requirements such as proportionality and long term stability. (Auth.)

  2. Observations of nonlinear behaviour in a low-pressure discharge column

    International Nuclear Information System (INIS)

    Cartier, S.L.; Merlino, R.L.

    1984-01-01

    Sudden and abrupt jumps in the plasma density and discharge current of low-pressure magnetized argon and helium plasmas are observed. These jumps are found to depend on the discharge bias voltage, the neutral gas pressure, and the magnetic field strength and occur with a substantial hysteresis in those parameters. These jumps are accompanied by the onset of intense and coherent low-frequency plasma oscillations. In addition, under certain conditions, the radial density profile of the plasma is found to be significantly different following a jump. Some possibly related plasma instabilities are discussed

  3. Long duration hard X-ray transatlantic payload

    International Nuclear Information System (INIS)

    La Padula, C.D.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; Patriarca, R.; Polcaro, V.F.; Ubertini, P.

    1981-01-01

    The HXR80M large-area hard X-ray experiment, to be flown aboard a transatlantic balloon, is described. The detectors are two multiwire spectroscopic proportional counters (MWSPC) with a 2700-sq-cm sensitive area each. The two detectors are filled with an extremely pure xenon-isobutane mixture at high pressure (3-6 atm) in order to obtain good spectral resolution and high efficiency. The onboard data handling is performed by microprocessor-controlled electronics. The scientific aim of the experiment is the survey of the sky belt around the 38th parallel and in particular the observation of faint galactic objects and galactic binary systems in the 15-200 keV range

  4. Study on low pressure evaporation of fresh water generation system model

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Han Shik; Wibowo, Supriyanto; Shin, Yong Han; Jeong, Hyo Min [Gyeongsang National University, Tongyeong (Korea, Republic of); Fajar, Berkah [University of Diponegoro, Semarang (Indonesia)

    2012-02-15

    A low pressure evaporation fresh water generation system is designed for converting brackish water or seawater into fresh water by distillation in low pressure and temperature. Distillation through evaporation of feed water and subsequent vapor condensation as evaporation produced fresh water were studied; tap water was employed as feed water. The system uses the ejector as a vacuum creator of the evaporator, which is one of the most important parts in the distillation process. Hence liquid can be evaporated at a lower temperature than at normal or atmospheric conditions. Various operating conditions, i.e. temperature of feed water and different orifice diameters, were applied in the experiment to investigate the characteristics of the system. It was found that these parameters have a significant effect on the performance of fresh water generation systems with low pressure evaporation.

  5. Detection systems for high energy particle producing gaseous ionization

    International Nuclear Information System (INIS)

    Martinez, L.; Duran, I.

    1985-01-01

    This report contains a review on the most used detectors based on the collection of the ionization produced by high energy particles: proportional counters, multiwire proportional chambers, Geiger-Muller counters and drift chambers. In six sections, the fundamental principles, the field configuration and useful gas mixtures, are discussed, most relevant devices are reported along 90 pages with 98 references. (Author) 98 refs

  6. Detection systems for high energy particle producing gaseous ionization; Sistemas de deteccion de particulas de alta energia mediante ionizacion gaseosa

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, L; Duran, I

    1985-07-01

    This report contains a review on the most used detectors based on the collection of the ionization produced by high energy particles: proportional counters, multiwire proportional chambers, Geiger-Muller counters and drift chambers. In six sections, the fundamental principles, the field configuration and useful gas mixtures, are discussed, most relevant devices are reported along 90 pages with 98 references. (Author) 98 refs.

  7. Very low pressure plasma sprayed yttria-stabilized zirconia coating using a low-energy plasma gun

    International Nuclear Information System (INIS)

    Zhu, Lin; Zhang, Nannan; Bolot, Rodolphe; Planche, Marie-Pierre; Liao, Hanlin; Coddet, Christian

    2011-01-01

    In the present study, a more economical low-energy plasma source was used to perform a very low pressure plasma-spray (VLPPS) process. The plasma-jet properties were analyzed by means of optical emission spectroscopy (OES). Moreover, yttria-stabilized zirconia coating (YSZ) was elaborated by a F100 low-power plasma gun under working pressure of 1 mbar, and the substrate specimens were partially shadowed by a baffle-plate during plasma spraying for obtaining different coating microstructures. Based on the SEM observation, a column-like grain coating was deposited by pure vapor deposition at the shadowed region, whereas, in the unshadowed region, the coating exhibited a binary microstructure which was formed by a mixed deposition of melted particles and evaporated particles. The mechanical properties of the coating were also well under investigation. (orig.)

  8. Modeling beam-front dynamics at low gas pressures

    International Nuclear Information System (INIS)

    Briggs, R.J.; Yu, S.

    1982-01-01

    The dynamics of space charge neutralization at the front of an intense self-focused electron beam pulse exhibits important differences in different gas pressure regimes. At very low pressures, the beam front is in the so-called ion-focused regime (IFR) where all secondary electrons are expelled from the beam region by the radial electric field without causing significant additional ionization. We estimate the upper pressure boundary of this regime by considering the distance scale length for cascade (avalanche) ionization. Data from the FX-25 diode experiments indicate a critical transition pressure (P/sub c/) that agrees with this estimate and with its scaling among various gas types. Normal mobility-limited treatments (local conductivity models) of the secondary electrons at the beam front are not justified until the gas pressure is 10 to 50 times higher than P/sub c/, due to runaway of these secondary electrons in the strong space-charge electric field at the lower pressures. The main conclusion of this study is that a non-local phase space (Boltzmann) treatment of the secondary electrons is required to accurately describe these different beam front regimes and the transitions between them; such a code model is currently under development

  9. New low pressure (LP) turbines for NE Krsko

    International Nuclear Information System (INIS)

    Nemcic, K.; Novsak, M.

    2004-01-01

    During the evaluation of possible future maintenance strategies on steam turbine in very short period of time, engineering decision was made by NE Krsko in agreement with Owners to replace the existing two Low Pressure (LP) Turbines with new upgrading LP Turbines. This decision is presented with review of the various steam turbine problems as: SCC on turbine discs; blades cracking; erosion-corrosion with comparison of various maintenance options and efforts undertaken by the NE Krsko to improve performance of the original low pressure turbines. This paper presents the NEK approach to solve the possible future problems with steam turbine operation in NE Krsko as pro-active engineering and maintenance activities on the steam turbine. This paper also presents improvements involving retrofits, confined to the main steam turbine path, with major differences between original and new LP Turbines as beneficial replacement because of turbine MWe upgrading and return capital expenditures.(author)

  10. The effect of pressurizer-water-level on the low frequency component of the pressure spectrum in a PWR

    International Nuclear Information System (INIS)

    Por, G.; Izsak, E.; Valko, J.

    1984-09-01

    The pressure fluctuations were measured in the cooling system of the Paks-1 reactor. A shift of the peak was detected in low frequency component of the pressure fluctuation spectrum which is due to the fluctuations of water level in the pressurizer. Using the model of Katona and Nagy (1983), the eigenfrequencies, the magnitude of the shift and the sensitivity to the pressurizer water level were reproduced in good accordance with the experimental data. (D.Gy.)

  11. Development of a 1200 KW/CYL low pressure dual fuel engine for LNG carriers

    Energy Technology Data Exchange (ETDEWEB)

    Grosshans, G. [S.E.M.T.-Pielstick, Thermodynamical Project Dept. (France)

    1998-12-31

    This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant fouling of the combustion chamber is still acceptable. (au)

  12. Magnetic and Structural Phase Transitions in Thulium under High Pressures and Low Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Vohra, Yogesh K.; Tsoi, Georgiy M.; Samudrala, Gopi K. [UAB

    2017-10-01

    The nature of 4f electrons in many rare earth metals and compounds may be broadly characterized as being either "localized" or "itinerant", and is held responsible for a wide range of physical and chemical properties. The pressure variable has a very dramatic effect on the electronic structure of rare earth metals which in turn drives a sequence of structural and magnetic transitions. We have carried out four-probe electrical resistance measurements on rare earth metal Thulium (Tm) under high pressures to 33 GPa and low temperatures to 10 K to monitor the magnetic ordering transition. These studies are complemented by angle dispersive x-ray diffraction studies to monitor crystallographic phase transitions at high pressures and low temperatures. We observe an abrupt increase in magnetic ordering temperature in Tm at a pressure of 17 GPa on phase transition from ambient pressure hcp-phase to α-Sm phase transition. In addition, measured equation of state (EOS) at low temperatures show anomalously low thermal expansion coefficients likely linked to magnetic transitions.

  13. Low temperature measurement of the vapor pressures of planetary molecules

    Science.gov (United States)

    Kraus, George F.

    1989-01-01

    Interpretation of planetary observations and proper modeling of planetary atmospheres are critically upon accurate laboratory data for the chemical and physical properties of the constitutes of the atmospheres. It is important that these data are taken over the appropriate range of parameters such as temperature, pressure, and composition. Availability of accurate, laboratory data for vapor pressures and equilibrium constants of condensed species at low temperatures is essential for photochemical and cloud models of the atmospheres of the outer planets. In the absence of such data, modelers have no choice but to assume values based on an educated guess. In those cases where higher temperature data are available, a standard procedure is to extrapolate these points to the lower temperatures using the Clausius-Clapeyron equation. Last summer the vapor pressures of acetylene (C2H2) hydrogen cyanide (HCN), and cyanoacetylene (HC3N) was measured using two different methods. At the higher temperatures 1 torr and 10 torr capacitance manometers were used. To measure very low pressures, a technique was used which is based on the infrared absorption of thin film (TFIR). This summer the vapor pressure of acetylene was measured the TFIR method. The vapor pressure of hydrogen sulfide (H2S) was measured using capacitance manometers. Results for H2O agree with literature data over the common range of temperature. At the lower temperatures the data lie slightly below the values predicted by extrapolation of the Clausius-Clapeyron equation. Thin film infrared (TFIR) data for acetylene lie significantly below the values predicted by extrapolation. It is hoped to bridge the gap between the low end of the CM data and the upper end of the TFIR data in the future using a new spinning rotor gauge.

  14. Design and implementation of an automatic pressure-control system for a mobile sprayer for greenhouse applications

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, R.; Pawlowski, A.; Rodriguez, C.; Guzman, J. L.; Sanchez-Hermosilla, J.

    2012-07-01

    This article presents the design and development of an embedded automatic pressure-control system for a mobile sprayer working in greenhouses. The pressure system is mounted on a commercial vehicle, it is composed of two on/off electro valves and one proportional electro valve. The hardware developed is based on an embedded microprocessor and provides a low-cost and robust solution. The resulting embedded system has been tested on a spraying system mounted on a manned vehicle. Furthermore, an easy-tuning non-linear PI (Proportional Integral) controller to achieve the desired pressure profile is designed and implemented in the embedded system. Many physical experiments show the best performance of such controller compared with a typical PI controller. Experiments covering the pressure range from 2 to 14 bar obtained a mean error less than 0.3 bar. Summing up, a low-cost automatic pressure-control system is developed, it ensures a uniform decomposition of the liquid sprayed on plants, and it works properly over a wide variable-pressure range. (Author) 17 refs.

  15. Epidural blood patch for refractory low CSF pressure headache: a pilot study.

    Science.gov (United States)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-08-01

    Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication/month). In our primary effect parameter we found a significant reduction in AUC with more than 25% and this is considered to be clinically relevant. We found also a significant and relevant reduction at -22% in intensity. A trend towards reduction in duration was seen. We found no statistically significant reduction in frequency. An increase in days with use of medication was found. Increased awareness of low CSF pressure headache is emphasized and a controlled larger randomized study is needed to confirm the results. However the present results, allows us to conclude that EBP in treatment-refractory low CSF pressure headache can be considered as a treatment option.

  16. Low Pressure Tolerance by Methanogens in an Aqueous Environment: Implications for Subsurface Life on Mars

    Science.gov (United States)

    Mickol, R. L.; Kral, T. A.

    2017-12-01

    The low pressure at the surface of Mars (average: 6 mbar) is one potentially biocidal factor that any extant life on the planet would need to endure. Near subsurface life, while shielded from ultraviolet radiation, would also be exposed to this low pressure environment, as the atmospheric gas-phase pressure increases very gradually with depth. Few studies have focused on low pressure as inhibitory to the growth or survival of organisms. However, recent work has uncovered a potential constraint to bacterial growth below 25 mbar. The study reported here tested the survivability of four methanogen species ( Methanothermobacter wolfeii, Methanosarcina barkeri, Methanobacterium formicicum, Methanococcus maripaludis) under low pressure conditions approaching average martian surface pressure (6 mbar - 143 mbar) in an aqueous environment. Each of the four species survived exposure of varying length (3 days - 21 days) at pressures down to 6 mbar. This research is an important stepping-stone to determining if methanogens can actively metabolize/grow under these low pressures. Additionally, the recently discovered recurring slope lineae suggest that liquid water columns may connect the surface to deeper levels in the subsurface. If that is the case, any organism being transported in the water column would encounter the changing pressures during the transport.

  17. Low Pressure Tolerance by Methanogens in an Aqueous Environment: Implications for Subsurface Life on Mars.

    Science.gov (United States)

    Mickol, R L; Kral, T A

    2017-12-01

    The low pressure at the surface of Mars (average: 6 mbar) is one potentially biocidal factor that any extant life on the planet would need to endure. Near subsurface life, while shielded from ultraviolet radiation, would also be exposed to this low pressure environment, as the atmospheric gas-phase pressure increases very gradually with depth. Few studies have focused on low pressure as inhibitory to the growth or survival of organisms. However, recent work has uncovered a potential constraint to bacterial growth below 25 mbar. The study reported here tested the survivability of four methanogen species (Methanothermobacter wolfeii, Methanosarcina barkeri, Methanobacterium formicicum, Methanococcus maripaludis) under low pressure conditions approaching average martian surface pressure (6 mbar - 143 mbar) in an aqueous environment. Each of the four species survived exposure of varying length (3 days - 21 days) at pressures down to 6 mbar. This research is an important stepping-stone to determining if methanogens can actively metabolize/grow under these low pressures. Additionally, the recently discovered recurring slope lineae suggest that liquid water columns may connect the surface to deeper levels in the subsurface. If that is the case, any organism being transported in the water column would encounter the changing pressures during the transport.

  18. Adsorption of helium gas near Tλ at low pressures

    International Nuclear Information System (INIS)

    Kachalin, G.V.; Kryukov, A.P.; Nesterov, S.B.

    1998-01-01

    Cryosorption of helium isotopes ( 4 He and 3 He) on thin argon cryo layers is studied experimentally in the temperature range 4.2-2 K at low pressures. It is shown that the sorption iso stere 4 He is anomalous at temperatures close to be temperature of the phase transition in the bulk of 4 He, T λ . An abrupt pressure change is observed for a 4 He film thickness approximately equal to two monolayers. The experiments on cryosorption of 3 He gas on an argon layer with a 3 He film thickness of approximately one monolayer display monotonous changes in the pressure within the whole temperature range

  19. THYC qualification on Vatican-1 low pressure tests

    International Nuclear Information System (INIS)

    Duval, C.; Guichard, J.

    1991-06-01

    PWR cores or fuel assemblies are components of a nuclear power plant involving single and two-phase flows in rod bundles. The knowledge of the detailed two-phase and three-dimensional flow patterns is necessary to evaluate the singularity (grids) and bypass effects on the Departure from Nucleate Boiling (DNB) in reactor cores during incidental transients. For that purpose, since 1989, the VATICAN experiment has been performed at EDF as a part of the qualification program of the three-dimensional computer code THYC, developed by EDF. The qualification strategy of the THYC software for PWR cores is the following: assuming the theoretical or experimental knowledge of regular and singular pressure drops and grid turbulence sources in single-phase, pressure drop multipliers and relative velocity in two-phase flow, the VATICAN experiment allows to evaluate the diffusion phenomena in two-phase flow. It provides thermalhydraulic measurements on a mock-up of a part of 900 MWe PWR fuel assembly in single and two-phase flows, with power and quality gradients. The first configuration of the mock-up, with simple spacer grids, is studied (VATICAN-1). The specific effects of mixing spacer grids will be compared to these data through a second configuration. The last void fraction measurements, using a γ-ray technique, performed on VATICAN-1 low pressure tests allowed to qualify a set of closure relations, particularly a model of little two-phase diffusion, adapted to two-phase flows at low pressure (5.0MPa). The qualification of subcooled boiling and diffusion models will continue on next VATICAN and other experimental campaigns [fr

  20. Multi-wire detector characterization for daily quality control on IMRT; Caracterizacao de um detector planar de multiplos fios para controle de qualidade diario de tratamentos com IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Vilma A.; Watanabe, Erika Y.; Santos, Gabriela R.; Menegussi, Gisela, E-mail: vilmaferrari@uol.com.br [Instituto do Cancer do Estado de Sao Paulo (ICESP), SP (Brazil). Setor de Radioterapia

    2012-08-15

    Several dosimetry devices are being developed for quality control of radiation treatments using modern techniques as, for example, the Intensity Modulated Radiation Therapy (IMRT). The main function of these devices are to daily quality control of treatments of patients submitted to IMRT technique. The aim of this study is to characterize a type of planar multi-wire detector - DAVID (PTW) - for use in clinical practice. It was evaluated the influence of the system in the radiation beam by measuring the absorption factors and surface dose. We also analyzed the dose-linearity, reproducibility, the dependence with the dose rate and the angle of the linac head. Small errors in the position of the multi-leaf were inserted to evaluate the sensitivity of the system. The results showed that the detector can absorb up to 6.7% of the dose, depending of the energy beam and the field size. A significant increase in surface dose was observed, indicating that individual analysis is necessary for each patient. The system showed good reproducibility, linear response with dose, low dependence with dose rate and low dependence with the angle of the linac head. When small errors were inserted in the position of the multi-leaf, the system was able to detect them. Thus, the detector DAVID proved to be suitable for daily verification of IMRT treatments. (author)

  1. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R.M. [Seattle Central College, 1701 Broadway, Seattle, WA 98122 (United States); Aalseth, C.E.; Day, A.R.; Hoppe, E.W. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Mace, E.K., E-mail: Emily.Mace@pnl.gov [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Moran, J.J.; Overman, C.T.; Panisko, M.E.; Seifert, A. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States)

    2016-03-21

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a natural methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium-counting efficiency while minimizing radiocarbon beta-decay interference. - Highlights: • Use of a single compound (methane) for dual tritium and radiocarbon measurements. • Optimized analysis window for simultaneous tritium and radiocarbon measurement. • Allows for optimization of tritium counting in the presence of radiocarbon.

  2. Optically driven self-oscillations of a silica nanospike at low gas pressures

    Science.gov (United States)

    Xie, Shangran; Pennetta, Riccardo; Noskov, Roman E.; Russell, Philip St. J.

    2016-09-01

    We report light-driven instability and optomechanical self-oscillation of a fused silica "nanospike" at low gas pressures. The nanospike (tip diameter 400 nm), fabricated by thermally tapering and HF-etching a single mode fiber (SMF), was set pointing at the endface of a hollow-core photonic crystal fiber (HC-PCF) into the field created by the fundamental optical mode emerging from the HC-PCF. At low pressures, the nanospike became unstable and began to self-oscillate for optical powers above a certain threshold, acting like a phonon laser or "phaser". Because the nanospike is robustly connected to the base, direct measurement of the temporal dynamics of the instability is possible. The experiment sheds light on why particles escape from optical traps at low pressures.

  3. Proportional counter with uniform electric field with Penning's mixture

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Zaremba, K.

    1984-01-01

    Some calculations are given and the design of proportional counters with a homogeneous electric field filled with Penning's mixtures, which ensure the best energy resolution is described. The counters with mixtures of Ne+Ar, Ne+CH 4 , Ne+CO 2 and Ar+C 2 H 2 have been checked. The admixtures (Ar, CH 4 , CO 2 , C 2 H 2 ) constitute from 0.1 to 2%, with pressure from 125 Tr to 760 Torr. The best energy resolution has been obtained for the mixture of Ne+1%CH 4 at the pressure of 190 Torr

  4. A study on the numerical instability of COBRA-series subchannel analysis codes at low-pressure and low-flow conditions

    International Nuclear Information System (INIS)

    Yoo, Y. J.; Hwnag, T. H.; Kim, K. K.; Ji, S. K.

    2001-01-01

    The numerical instability at low-pressure and low-flow conditions has been confirmed to be the common problem of the existing COBRA-series subchannel analysis codes. In addition, the range of operating conditions at which the analyses by the codes are impossible has been evaluated. To evaluate the MATRA's inapplicable range of operating conditions of the SMART core that is to be operated at the low flow condition, i.e. about 30% of the flow of the existing commercial pressurized water reactors at the steady-state condition, the analyses of various operating conditions were performed by using several representative COBRA-series subchannel analysis codes including MATRA. TORC of CE, COBRA3CP of Siemens/KWU, COBRA4I of PNL, and MATRA of KAERI were chosen as the subchannel analysis codes to be evaluated. The various operating conditions used in the CHF tests carried out at the Winfrith Establishment of UKAEA were chosen as the conditions to be analyzed. As the result, the numerical instabilities at low-pressure and low-flow conditions occurred in the analyses by all of the codes. It was revealed that the MATRA code, which numerically more stable thatn the other codes, was not able to analyze the conditions of the pressure not more than 100 bar and the mass velocity not more than 300 kg/sec-m 2 . Hereafter it is required to find out the exact reason for the numerical instability of the existing COBRA-series subchannel analysis codes at low-pressure and low-flow conditions and to devise the new method to get over that numerical problem

  5. New hard X-ray sources at 38/sup 0/ declination

    Energy Technology Data Exchange (ETDEWEB)

    Ubertini, P.; Bazzano, A.; La Padula, C.; Polcaro, V.F. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale)

    1981-01-01

    We report the detection of three new hard X-rays sources emitting in the range 15-150 KeV. Their observation was carried out by means of a balloon borne payload, consisting of two large area high spectral resolution Multiwire Spectroscopic Proportional Counters.

  6. Low cost sonoluminescence experiment in pressurized water

    Science.gov (United States)

    Bernal, L.; Insabella, M.; Bilbao, L.

    2012-06-01

    We present a low cost design for demostration and mesurements of light emmision from a sonoluminescence experiment. Using presurized water introduced in an acrylic cylinder and one piezoelectric from an ultrasonic cleaner, we are able to generate cavitacion zones with emission of light. The use of argon to pressurize the water improves the emission an the light can be seen at naked eye in a softlit ambient.

  7. Analysis of Pressure Variations in a Low-Pressure Nickel-Hydrogen Battery – Part 1

    Science.gov (United States)

    Purushothaman, B. K.; Wainright, J. S.

    2012-01-01

    A low pressure nickel-hydrogen battery using either a metal hydride or gaseous hydrogen for H2 storage has been developed for use in implantable neuroprosthetic devices. In this paper, pressure variations inside the cell for the gaseous hydrogen version are analyzed and correlated with oxygen evolution side reaction at the end of charging, the recombination of oxygen with hydrogen during charging and a subsequent rest period, and the self-discharge of the nickel electrode. About 70% of the recombination occurred simultaneously with oxygen evolution during charging and the remaining oxygen recombined with hydrogen during the 1st hour after charging. Self-discharge of the cell varies linearly with hydrogen pressure at a given state of charge and increased with increasing battery charge levels. The coulometric efficiency calculated based on analysis of the pressure-time data agreed well with the efficiency calculated based on the current-time data. Pressure variations in the battery are simulated accurately to predict coulometric efficiency and the state of charge of the cell, factors of extreme importance for a battery intended for implantation within the human body. PMID:22423175

  8. Pulsed laser ablation of silicon with low laser fluence in a low-pressure of ammonia ambient

    International Nuclear Information System (INIS)

    Choo, Cheow-Keong; Tohara, Makoto; Enomoto, Kazuhiro; Tanaka, Katsumi

    2004-01-01

    Silicon was ablated by 532 nm wavelength of Nd:YAG laser in ammonia gas ambient. The influence of laser fluence and gas ambient pressures between 1.33x10 1 to 1.33x10 -5 Pa on the deposited compound was studied by in situ X-ray photoelectron spectroscopy and transmission Fourier transform infrared spectroscopy techniques. The results indicate that the deposited compound is composed of nonstoichiometric silicon nitride (SiN x , x=0-0.84). It has been shown that the composition of nitrogen to silicon is sensitive to the laser fluence; it increases with decreasing laser fluence. However, the ammonia gas ambient in these low pressures range had no influence on the composition of the deposited compound. The reaction of the ablated silicon with low-pressure ambient ammonia is proposed to be occurred on the substrate

  9. Excessively High Vapor Pressure of Al-based Amorphous Alloys

    Directory of Open Access Journals (Sweden)

    Jae Im Jeong

    2015-10-01

    Full Text Available Aluminum-based amorphous alloys exhibited an abnormally high vapor pressure at their approximate glass transition temperatures. The vapor pressure was confirmed by the formation of Al nanocrystallites from condensation, which was attributed to weight loss of the amorphous alloys. The amount of weight loss varied with the amorphous alloy compositions and was inversely proportional to their glass-forming ability. The vapor pressure of the amorphous alloys around 573 K was close to the vapor pressure of crystalline Al near its melting temperature, 873 K. Our results strongly suggest the possibility of fabricating nanocrystallites or thin films by evaporation at low temperatures.

  10. A study on the manufacturing conditions of metal matrix composites by low pressure infiltration process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Jo; Hessian, Md Anowar; Park, Sung Ho [Gyeongsang National University, Tongyoung (Korea, Republic of); Huh, Sun Chul [Gyeongsang National University, JinJu (Korea, Republic of)

    2007-10-15

    Metal fiber preform reinforced aluminum alloy composite as made by the infiltration of molten metal under low pressure casting process. The infiltration behavior of filling pattern and the velocity profile with low-pressure casting process was investigated. The thermocouple was inserted into the preform in order to observe the infiltration behavior. The infiltration of applied pressure time, 1, 2 and 5 s under constant pressure of 0.4 MPa was completely filled during 0.4 s. In these conditions, molten aluminum alloy has successfully infiltrated to FeCrSi metal fiber preform by low-pressure casting process. It was observed the porosity of composites for reliability of composites. The automobile piston was developed with FeCrSi reinforced aluminum alloy that is 0% porosity by the optimal applied pressure and applied pressure time.

  11. Low proportion of high school senior athletes receiving recommended immunizations.

    Science.gov (United States)

    Karpinos, Ashley Rowatt; Rizzone, Katherine H; Cribbs, Sarah P; Roumie, Christianne L

    2014-05-01

    The preparticipation physical evaluation (PPE) often serves as the only preventive health care visit for athletes, but immunization status is not uniformly addressed in such visits. Thus, athletes may not be receiving recommended immunizations. Our aim was to determine the proportion of high school senior athletes who received all recommended immunizations. Our hypothesis was that females would be less likely than males to receive all recommended immunizations given suboptimal human papillomavirus (HPV) vaccine uptake. We conducted a cross-sectional survey evaluation of the immunization status of high school senior athletes in Davidson County, TN. The primary composite outcome was receipt of recommended immunizations for tetanus, meningococcal, and seasonal influenza. For females, the primary outcome also included completion of the HPV series. A total of 162 participants, 104 males and 58 females, were included. More males than females received all recommended immunizations (15.4% vs 3.5%; P = 0.02). When HPV immunization was excluded from the composite outcome, there was no difference in the proportion of males and females who received all recommended immunizations (15.4% vs 15.5%; P = 0.98). The odds of receiving all recommended immunizations was 0.14 (95% CI, 0.03-0.72) for females compared with males when adjusted for covariates. Athletes seen at retail-based clinics for their PPE were less likely to receive all recommended immunizations compared with athletes seen in primary care (OR, 0.13; 95% CI, 0.02-0.69). Only 1 in 6 high school senior athletes received the recommended tetanus, meningococcal, and influenza immunizations. A lower proportion of females, only 1 in 28, received all recommended immunizations due to the HPV series. Policy changes requiring a review of immunizations at the PPE would benefit many high school athletes.

  12. Effect of Low Pressure End Conditions on Steam Power Plant Performance

    Directory of Open Access Journals (Sweden)

    Ali Syed Haider

    2014-07-01

    Full Text Available Most of the electricity produced throughout the world today is from steam power plants and improving the performance of power plants is crucial to minimize the greenhouse gas emissions and fuel consumption. Energy efficiency of a thermal power plant strongly depends on its boiler-condenser operating conditions. The low pressure end conditions of a condenser have influence on the power output, steam consumption and efficiency of a plant. Hence, the objective this paper is to study the effect of the low pressure end conditions on a steam power plant performance. For the study each component was modelled thermodynamically. Simulation was done and the results showed that performance of the condenser is highly a function of its pressure which in turn depends on the flow rate and temperature of the cooling water. Furthermore, when the condenser pressure increases both net power output and plant efficiency decrease whereas the steam consumption increases. The results can be used to run a steam power cycle at optimum conditions.

  13. Icon arrays help younger children's proportional reasoning.

    Science.gov (United States)

    Ruggeri, Azzurra; Vagharchakian, Laurianne; Xu, Fei

    2018-06-01

    We investigated the effects of two context variables, presentation format (icon arrays or numerical frequencies) and time limitation (limited or unlimited time), on the proportional reasoning abilities of children aged 7 and 10 years, as well as adults. Participants had to select, between two sets of tokens, the one that offered the highest likelihood of drawing a gold token, that is, the set of elements with the greater proportion of gold tokens. Results show that participants performed better in the unlimited time condition. Moreover, besides a general developmental improvement in accuracy, our results show that younger children performed better when proportions were presented as icon arrays, whereas older children and adults were similarly accurate in the two presentation format conditions. Statement of contribution What is already known on this subject? There is a developmental improvement in proportional reasoning accuracy. Icon arrays facilitate reasoning in adults with low numeracy. What does this study add? Participants were more accurate when they were given more time to make the proportional judgement. Younger children's proportional reasoning was more accurate when they were presented with icon arrays. Proportional reasoning abilities correlate with working memory, approximate number system, and subitizing skills. © 2018 The British Psychological Society.

  14. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  15. Blood pressure response to conventional and low-dose enalapril in chronic renal failure

    DEFF Research Database (Denmark)

    Elung-Jensen, Thomas; Heisterberg, Jens; Kamper, Anne-Lise

    2003-01-01

    AIMS: In chronic renal failure, the clearance of most ACE inhibitors including enalapril is reduced. Hence, with conventional dosage, plasma enalaprilat may be markedly elevated. It is unclear whether this excess of drug exposure affords an improved control of blood pressure. The aim of the present...... study was to evaluate short-term blood pressure response to two different plasma levels of enalaprilat. METHODS: As part of an open, randomized, controlled trial of the effect of high and low dosage of enalapril on the progression of renal failure, short-term blood pressure response was evaluated. Data...... potassium concentrations at day 90 and patients in the low group experienced a slight increase in GFR. CONCLUSIONS: In moderate to severe chronic renal insufficiency the same degree of blood pressure control was achieved on low as well as moderate daily doses of enalapril. This was irrespective...

  16. Randomized trial of low versus high carbon dioxide insufflation pressures in posterior retroperitoneoscopic adrenalectomy.

    Science.gov (United States)

    Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark

    2018-05-01

    Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Modelling for post-dryout heat transfer and droplet sizes at low pressure and low flow conditions

    International Nuclear Information System (INIS)

    Jeong, H.Y.; No, H.C.

    1996-01-01

    A correlation describing the initial droplet size just after the CHF position at low mass flux is suggested through regression analysis. The history-dependent post-dryout model of Varone and Rohsenow replaced by the Webb-Chen model for wall-vapor heat transfer is used as a reference model in the analysis. In the post-dryout region at low pressure and low flow, it is found that the suggested one-dimensional mechanistic model is valid only in the churn-turbulent flow regime (j* g = 0.5 ∼ 4.5). It is also suggested that the droplet size generated from the churn-turbulent surface is dependent not only on the pressure but also on the vapor velocity. It turns out that the present model can predict the measured cladding and vapor temperatures within 20% and 15%, respectively

  18. New hard X-ray sources at 380 declination

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; La Padula, C.; Polcaro, V.F.

    1981-01-01

    We report the detection of three new hard X-rays sources emitting in the range 15-150 KeV. Their observation was carried out by means of a balloon borne payload, consisting of two large area high spectral resolution Multiwire Spectroscopic Proportional Counters. (orig.)

  19. Diffusion proton-proton à petits angles (2° lab 8°) entre 290 et 570 MeV

    CERN Document Server

    Aebischer, D; Heer, E; Hess, R; Junod, A; Lechanom, C; Nikles, J C; Serre, C; Werren, D W

    1972-01-01

    Abstract only given. Measurements of the differential cross section for elastic proton-proton scattering in the Coulomb interference region have been made using the CERN synchrocyclotron. The experimental device, consisting essentially of an ensemble of multiwire proportional counters, is described and preliminary results presented.

  20. Pressure ulcer incidence and progression in critically ill subjects: influence of low air loss mattress versus a powered air pressure redistribution mattress.

    Science.gov (United States)

    Black, Joyce; Berke, Christine; Urzendowski, Gail

    2012-01-01

    The primary objective of this study was to compare facility-acquired pressure ulcer incidence and progression of pressure ulcers present on admission in critically ill patients, using 2 different support surfaces. We completed a comparison cohort study in a surgical intensive care unit (ICU). The study setting was a 12-bed cardiovascular ICU in a university-based hospital in the Midwestern United States. The sample comprised 52 critically ill patients; 31 were placed on low air loss weight-based pressure redistribution-microclimate management system beds and 21 were placed on integrated powered air pressure redistribution beds. Prior to the start of the study, 5 low airloss beds were placed in open rooms in the cardiovascular surgical ICU. Inclusion criteria were anticipated ICU stay of 3 days, and patients did not receive a speciality bed for pulmonary or wound issues. Initial assessment of the patients included risk assessment and prior events that would increase risk for pressure ulcer development such as extended time in operating room, along with skin assessment for existing pressure ulcers. Subjects in both groups had ongoing skin assessment every 3 to 4 days and a subjective evaluation of heel elevation and turning or repositioning by the researcher. Data were collected until the subjects were dismissed from the ICU. Patients admitted to the unit were assigned to open rooms following the usual protocols. The mean length of stay was 7.0 days, with an 8.1-day length of stay for subjects on "low air loss with microclimate management" beds (LAL-MCM) and 6.6 days on the integrated power pressure air redistribution (IP-AR) beds (P = NS). The incidence of pressure ulcers on the buttocks, sacrum, or coccyx was 0% (0/31) on the low air loss bed and 18% (4/21) on the IP-AR bed (P = .046). Five subjects had 6 pressure ulcers on admission. Two pressure ulcers on 2 patients worsened on the integrated power air redistribution beds, which required specialty bed rental

  1. Responses of low pressure Andersen sampler for collecting substrates

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, K. [Research Reactor Institute, Kyoto University, Osaka (Japan); Yamada, Y.; Miyamoto, K.; Shimo, M. [Division of Radiotoxicology and Protection, National Institute of Radiological Sciences, Chiba (Japan)

    2000-05-01

    Some types of low pressure cascade impactors (Andersen, Berner, Davies, and MOUDI etc) have been used to measure the activity size distribution of radon progeny in the environment. In spite of their careful uses, their nonideal responses are not adequately known. Some important factors such as the wall loss, electrostatic attraction, and the surface nature of collecting substrates may affect the reliability of the impactor data. Size selective characteristics of a low pressure Andersen sampler for various collecting substrates were examined in a radon exposure chamber using several kinds of liquid (DOS) or solid (carnauba wax) carrier aerosols labelled with radon progeny. These carrier aerosols were produced by commercial condensation aerosol generator. Tested collecting substrates were, (1) uncoated clean stainless steel plate, (2) silicone oil or grease coated stainless steel plate, (3) polyethylene sheet covered stainless steel plate, (4) membrane filter, (5) glass fiber filter, and (6) quartz fiber filter. In the case of collecting liquid or sticky carrier aerosols, the effect of particle bounce was small and nearly any substrates might used on the impaction plate. On the other hand, in the case of solid carrier aerosols, an adhesive layer such as grease or oil might have to be applied to the substrate. It was concluded that a low pressure cascade impactor such as Andersen sampler might need an appropriate calibration procedure including the interstage characteristics for determining the accurate activity size distribution. (author)

  2. $\\mu$SR-Measurements under High Pressure and at Low Temperatures

    CERN Multimedia

    2002-01-01

    High pressure causes changes in the volume available to each atom in a solid and will therefore influence local properties like the electronic charge and spin densities and, in the case of magnetic materials, the spin ordering.\\\\ \\\\ The positive muon is known to be an interesting probe particle for the study of certain problems in magnetism. It has in fact been used for one high pressure experiment earlier in CERN, but the present experiments aim at more systematic studie For this purpose it is necessary to carry out pressure experiments at low temperatures. The new experiments use a helium gas pressure system, which covers the temperature range 10-300 K at pressures up to 14 Kbar.\\\\ \\\\ Experiments are in progress on \\item 1)~~~~Ferromagnetic metals like Fe, Co, Ni where the pressure dependence of the local magnetic field ~~~is studied at 77 K and at room temperature. \\item 2)~~~~Knight shifts in semimetals, where in the case of Sb strong variations with temperature and ~~~pressure are observed. \\end{enumerat...

  3. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  4. Epidural blood patch for refractory low CSF pressure headache: a pilot study

    OpenAIRE

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate th...

  5. Experimental study on low pressure flow instability

    International Nuclear Information System (INIS)

    Jiang Shengyao; Wu Xinxin; Wu Shaorong; Bo Jinhai; Zhang Youjie

    1997-05-01

    The experiment was performed on the test loop (HRTL-5), which simulates the geometry and system design of the 5 MW reactor. The flow behavior for a wide range of inlet subcooling, in which the flow undergoes from single phase to two phase, is described in a natural circulation system at low pressure (p = 0.1, 0.24 MPa). Several kinds of flow instability, e.g. subcooled boiling instability, subcooled boiling induced flashing instability, pure flashing instability as well as flashing coupled density wave instability and high frequency flow oscillation, are investigated. The mechanism of flashing and flashing concerned flow instability, which has never been studied well in this field, is especially interpreted. The experimental results show that, firstly, for a low pressure natural circulation system the two phase flow is unstable in most of inlet subcooling conditions, the two phase stable flow can only be reached at very low inlet subcooling; secondly, at high inlet subcooling the flow instability is dominated by subcooled boiling in the heated section, and at middle inlet subcooling is dominated by void flashing in the adiabatic long riser; thirdly, in two phase stable flow region the condition for boiling out of the core, namely, single phase flow in the heated section, two phase flow in the riser due to vapor flashing, can be realized. The experimental results are very important for the design and accident analysis of the vessel and swimming pool type natural circulation nuclear heating reactor. (7 refs., 10 figs., 1 tab.)

  6. Design report on a 10-in. multiwire proportional chamber (MWPC) and associated electronics

    International Nuclear Information System (INIS)

    MacArthur, D.W.

    1987-02-01

    We discuss the design and specifications of a 10-in. x 10-in. active area wire chamber. Several of these chambers will be combined with polyethylene converters to make a large volume detector intended for use as a high-energy detector displaying moderate energy resolution. We also discuss the amplifiers and discriminators that have been designed for these chambers. This report only concerns the wire chambers and electronics

  7. [Development of an inexpensive, high resolution positron multiwire proportional counter]. Progress report, 1985

    International Nuclear Information System (INIS)

    1986-01-01

    The 10cm chamber had been used in conjunction with the new reconstruction algorithm. Ongoing investigations are testing system performance, including three-dimensional resolution and contrast ratio for various objects. The chambers have experienced reliability problems, even with the 90% argon-10% ethane mixture. This new gas has helped stability somewhat, but we must still compromise sensitivity by running at less than desired anode voltages. This results in two effects: loss of anode events, and a reduced number of valid cathode events. This translates into a reduced coincidence event rate. Some electronic problems have also developed, resulting in the loss of one anode amplifier in chamber 1 and a non-uniform cathode sensitivity in chamber 2. 4 refs., 4 figs

  8. The Healing Effect of Low-Temperature Atmospheric-Pressure Plasma in Pressure Ulcer: A Randomized Controlled Trial.

    Science.gov (United States)

    Chuangsuwanich, Apirag; Assadamongkol, Tananchai; Boonyawan, Dheerawan

    2016-12-01

    Pressure ulcers are difficult to treat. Recent reports of low-temperature atmospheric-pressure plasma (LTAPP) indicated its safe and effectiveness in chronic wound care management. It has been shown both in vitro and vivo studies that LTAPP not only helps facilitate wound healing but also has antimicrobial efficacy due to its composition of ion and electron, free radicals, and ultraviolet ray. We studied the beneficial effect of LTAPP specifically on pressure ulcers. In a prospective randomized study, 50 patients with pressure ulcers were divided into 2 groups: Control group received standard wound care and the study group was treated with LTAPP once every week for 8 consecutive weeks in addition to standard wound care. We found that the group treated with LTAPP had significantly better PUSH (Pressure Ulcer Scale for Healing) scores and exudate amount after 1 week of treatment. There was also a reduction in bacterial load after 1 treatment regardless of the species of bacteria identified.

  9. Pressurized-helium breakdown at very low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Metas, R J

    1972-06-01

    An investigation of the electrical-breakdown behavior of helium at very low temperatures has been carried out to assist the design and development of superconducting power cables. At very high densities, both liquid and gaseous helium showed an enhancement in electric strength when pressurized to a few atmospheres; conditioned values of breakdown fields then varied between 30 and 45 MV/m. Breakdown processes occurring over a wide range of helium densities are discussed. 24 references.

  10. Critical heat flux of water in vertical round tubes at low-pressure and low-flow conditions

    International Nuclear Information System (INIS)

    Park, Jae-Wook; Kim, Hong-Chae; Beak, Won-Pil; Chang, Soon Heung

    1997-01-01

    A series of critical heat flux (CHF) tests have been performed to provide a reliable set of CHF data for water flow in vertical round tubes at low pressure and low flow (LPLF) conditions. The range of experimental conditions is as follows: diameter 8, 10 mm; heated length 0.5, 1 m; pressure 2-9 bar, mass flux 50-200 kg/m 2 s; inlet subcooling 350, 450 kJ/kg. The observed parametric trends are generally consistent with the previous understanding except for the effects of system pressure and tube diameter. The pressure effect is small but very complicated; existing CHF correlations do not represent this parametric trend properly. CHF increases with the increase in diameter at fixed exit conditions, contrary to the general understanding. The artificial neural networks are applied to the round tube CHF data base at LPLF (P = 110-1100 kPa, G = 0-500 kg/m 2 s) conditions. The trained backpropagation networks (BPNs) predict CHF better than any other CHF correlations. Parametric trends of CHF based on the BPN for fixed inlet conditions generally agree well with our experimental results. (author)

  11. Bulk characterization of pharmaceutical powders by low-pressure compression

    DEFF Research Database (Denmark)

    Sørensen, A.H.; Sonnergaard, Jørn; Hovgaard, L.

    2005-01-01

    Low-pressure compression of pharmaceutical powders using small amounts of sample (50 mg) was evaluated as an alternative to traditional bulk powder characterization by tapping volumetry. Material parameters were extrapolated directly from the compression data and by fitting with the Walker...

  12. Ethernet based data logger for gaseous detectors

    Science.gov (United States)

    Swain, S.; Sahu, P. K.; Sahu, S. K.

    2018-05-01

    A data logger is designed to monitor and record ambient parameters such as temperature, pressure and relative humidity along with gas flow rate as a function of time. These parameters are required for understanding the characteristics of gas-filled detectors such as Gas Electron Multiplier (GEM) and Multi-Wire Proportional Counter (MWPC). The data logger has different microcontrollers and has been interfaced to an ethernet port with a local LCD unit for displaying all measured parameters. In this article, the explanation of the data logger design, hardware, and software description of the master microcontroller and the DAQ system along with LabVIEW interface client program have been presented. We have implemented this device with GEM detector and displayed few preliminary results as a function of above parameters.

  13. A visualization experiment on a stopping pion beam using charged particles

    International Nuclear Information System (INIS)

    Daniel, H.; Reidy, J.; Helland, J.; Bradbury, J.; Hutson, R.

    1976-01-01

    It has been demonstrated that the stopping density of positive pions coming to rest in an object can be measured by detecting positrons, emitted as a result of the pion-to-muon-to-positron decay, with multiwire proportional counters. More sophisticated set-ups are discussed. (orig.) [de

  14. Pulse triggering mechanism of air proportional counters

    International Nuclear Information System (INIS)

    Aoyama, T.; Mori, T.; Watanabe, T.

    1983-01-01

    This paper describes the pulse triggering mechanism of a cylindrical proportional counter filled with air at atmospheric pressure for the incidence of β-rays. Experimental results indicate that primary electrons created distantly from the anode wire by a β-ray are transformed into negative ions, which then detach electrons close to the anode wire and generate electron avalanches thus triggering pulses, while electrons created near the anode wire by a β-ray directly trigger a pulse. Since a negative ion pulse is triggered by a single electron detached from a negative ion, multiple pulses are generated by a large number of ions produced by the incidence of a single β-ray. It is therefore necessary not to count pulses triggered by negative ions but to count those by primary electrons alone when use is made of air proportional counters for the detection of β-rays. (orig.)

  15. Unimolecular decomposition reactions at low-pressure: A comparison of competitive methods

    Science.gov (United States)

    Adams, G. F.

    1980-01-01

    The lack of a simple rate coefficient expression to describe the pressure and temperature dependence hampers chemical modeling of flame systems. Recently developed simplified models to describe unimolecular processes include the calculation of rate constants for thermal unimolecular reactions and recombinations at the low pressure limit, at the high pressure limit and in the intermediate fall-off region. Comparison between two different applications of Troe's simplified model and a comparison between the simplified model and the classic RRKM theory are described.

  16. Proton-recoil proportional counter tests at TREAT

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; Burrows, D.R.; DeVolpi, A.

    1979-01-01

    A methane filled proton-recoil proportional counter will be used as a fission neutron detector in the fast-neutron hodoscope. To provide meaningful fuel-motion information the proportional counter should have: a linear response over a wide range of reactor powers background ratio (the number of high energy neutrons detected must be maximized relative to low energy neutrons, and gamma ray sensitivity must be kept small); and a detector efficiency for fission neutrons above 1 MeV of approximately 1%. In addition, it is desirable that the detector and the associated amplifier/discriminator be capable of operating at counting rates in excess of 500 kHz. This paper reports on tests that were conducted on several proportional counters at the TREAT reactor

  17. Position-sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hendrix, J.

    1982-01-01

    In this review of the application of different types of position sensitive detectors to synchrotron radiation, discussion of the proportional counters based on the gas amplification principle forms a major part. Other topics reviewed are detector requirements, multiwire proportional chamber system, drift chamber type detectors, TV detectors, and recent developments, such as that based on a micro-channel plate as the amplifying element, and charge-coupled devices. (U.K.)

  18. Golden Jubilee photos: A New Class of Detectors

    CERN Multimedia

    2004-01-01

    In the 1960s, detection in particle physics mainly meant examining millions of photographs from bubble chambers or spark chambers. This was slow, labour intensive and not suitable for studies into rare phenomena, so there was a bottleneck that could have affected further progress in high energy physics. The transistor revolution triggered new ideas. While a camera could detect a spark, a detector wire connected to an amplifier could detect a much smaller effect. In 1968, Georges Charpak developed the 'multiwire proportional chamber', a gas-filled box with a large number of parallel detector wires, each connected to individual amplifiers. Linked to a computer, it could achieve a counting rate a thousand times better than existing techniques - without a camera in sight. Today practically every experiment in particle physics uses some type of track detector that is based on the principle of the multiwire proportional chamber. The technology is also used in many other fields using ionising radiation such as biol...

  19. A low pressure bipolar nickel-hydrogen battery

    Energy Technology Data Exchange (ETDEWEB)

    Golben, M.; Nechev, K.; DaCosta, D.H.; Rosso, M.J.

    1997-12-01

    Ergenics is developing a low pressure high power rechargeable battery for electric vehicles and other large battery applications. The Hy-Stor{trademark} battery couples a bipolar nickel-hydrogen electrochemical system with the high energy storage density of metal hydride technology. In addition to its long cycle life, high specific power, and energy density, this battery offers safety and economic advantages over other rechargeable batteries. Results from preliminary testing of the first Hy-Stor battery are presented.

  20. Protonation enhancement by dichloromethane doping in low-pressure photoionization.

    Science.gov (United States)

    Shu, Jinian; Zou, Yao; Xu, Ce; Li, Zhen; Sun, Wanqi; Yang, Bo; Zhang, Haixu; Zhang, Peng; Ma, Pengkun

    2016-12-01

    Doping has been used to enhance the ionization efficiency of analytes in atmospheric pressure photoionization, which is based on charge exchange. Compounds with excellent ionization efficiencies are usually chosen as dopants. In this paper, we report a new phenomenon observed in low-pressure photoionization: Protonation enhancement by dichloromethane (CH 2 Cl 2 ) doping. CH 2 Cl 2 is not a common dopant due to its high ionization energy (11.33 eV). The low-pressure photoionization source was built using a krypton VUV lamp that emits photons with energies of 10.0 and 10.6 eV and was operated at ~500-1000 Pa. Protonation of water, methanol, ethanol, and acetaldehyde was respectively enhanced by 481.7 ± 122.4, 197.8 ± 18.8, 87.3 ± 7.8, and 93.5 ± 35.5 times after doping 291 ppmv CH 2 Cl 2 , meanwhile CH 2 Cl 2 almost does not generate noticeable ions itself. This phenomenon has not been documented in the literature. A new protonation process involving in ion-pair and H-bond formations was proposed to expound the phenomenon. The observed phenomenon opens a new prospect for the improvement of the detection efficiency of VUV photoionization.

  1. High- and low-pressure operation of the gas electron multiplier

    International Nuclear Information System (INIS)

    Bondar, A.; Buzulutskov, A.; Shekhtman, L.; Sauli, F.

    1998-01-01

    We have studied the operation of the gas electron multiplier (GEM) in gas mixtures Xe-CO 2 , Ar-CO 2 and CH 4 at different pressures varying from 0.1 to 5 atm. In Ar- and Xe-based mixtures, the maximum GEM gain considerably decreases with pressure, from a few hundreds at 1 atm to below 10 at 5 atm. Combined gain of GEM and the micro-strip gas chamber (MSGC) can exceed values of 10000 at 1 atm and 100 at 5 atm. High GEM gains, of above 1000, were obtained in CH 4 at low pressures. We have observed the effect of the avalanche confinement in GEM micro-holes, resulting in violation of the pressure scaling and in the possibility of GEM operation in pure noble gases. (author)

  2. Replacement of low pressure reheater and performance evaluation on domestic NPP moisture separator reheater

    International Nuclear Information System (INIS)

    Choi, Y. S.; Jeong, W. T.; Shon, S. Y.; Kim, M. H.

    2003-01-01

    Moisture Separator Reheater is one of the most important equipment for the integrity of low pressure turbine and the total efficiency of the nuclear power plant, It supplies the dry steam to low pressure turbine after separation of moisture and reheating the wet steam out of high pressure turbine. This equipment is always operated under severe conditions, therefore it should be carefully maintained for safe operation and operating confidence. After replacement low pressure reheater of moister separator reheater on domestic nuclear power plant, there was MSR performance degradation and vibration of condensate drain line. So I found out root cause and commented a solution, site people modified the equipment. Finally I concluded the performanc of MSR was good condition, after I inspected the equipment and evaluated the performance of MSR

  3. An experimental study on two-phase flow pattern in low pressure natural circulation system

    International Nuclear Information System (INIS)

    Wu Shaorong; Han Bing; Zhou Lei; Zhang Youjie; Jiang Shengyao; Wu Xinxin

    1991-10-01

    An experimental study on two-phase flow pattern in the riser of low pressure natural circulation system was performed. The local differential pressure signal was analysed for flow pattern. It is considered that Sr f·d/v can be used to distinguish different flow patterns and it has clear and definite physical meaning. Flow patterns at different inlet temperature with different system pressures (1.5 MPa, 0.24 MPa and 0.1 MPa) are described. It is considered that the flow pattern is only bubble flow without flow pattern change during the period of low quality density-wave instability at 1.5 MPa. There is no density-wave oscillation in the system, when flow pattern is in bubble-intermittent transition area. The effect of flash vaporization on stability at low pressure is discussed

  4. Proportionality lost - proportionality regained?

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2010-01-01

    In recent years, the European Court of Justice (the ECJ) seems to have accepted restrictions on the freedom of establishment and other basic freedoms, despite the fact that a more thorough proportionality test would have revealed that the restriction in question did not pass the 'rule of reason' ...

  5. A model for the operation of helium-filled proportional counter at low temperatures near 4.2 K

    International Nuclear Information System (INIS)

    Masaoka, Sei; Katano, Rintaro; Kishimoto, Shunji; Isozumi, Yasuhito

    2000-01-01

    In order to understand the operation of helium-filled proportional counter (HFPC) from the standpoint of fundamental atomic and molecular processes, we have surveyed previous works on collision processes in discharged helium gas. By analyzing gas gain curve, after-pulses and discharge current experimentally observed at 4.2 K, the electron avalanche and the secondary electron emission from cathode have been related to the collision processes in helium. A simplified model for the HFPC operation at low temperatures near 4.2 K has been constructed with the related processes

  6. An Ultra-low Frequency Modal Testing Suspension System for High Precision Air Pressure Control

    Directory of Open Access Journals (Sweden)

    Qiaoling YUAN

    2014-05-01

    Full Text Available As a resolution for air pressure control challenges in ultra-low frequency modal testing suspension systems, an incremental PID control algorithm with dead band is applied to achieve high-precision pressure control. We also develop a set of independent hardware and software systems for high-precision pressure control solutions. Taking control system versatility, scalability, reliability, and other aspects into considerations, a two-level communication employing Ethernet and CAN bus, is adopted to complete such tasks as data exchange between the IPC, the main board and the control board ,and the pressure control. Furthermore, we build a single set of ultra-low frequency modal testing suspension system and complete pressure control experiments, which achieve the desired results and thus confirm that the high-precision pressure control subsystem is reasonable and reliable.

  7. LDPC Codes with Minimum Distance Proportional to Block Size

    Science.gov (United States)

    Divsalar, Dariush; Jones, Christopher; Dolinar, Samuel; Thorpe, Jeremy

    2009-01-01

    Low-density parity-check (LDPC) codes characterized by minimum Hamming distances proportional to block sizes have been demonstrated. Like the codes mentioned in the immediately preceding article, the present codes are error-correcting codes suitable for use in a variety of wireless data-communication systems that include noisy channels. The previously mentioned codes have low decoding thresholds and reasonably low error floors. However, the minimum Hamming distances of those codes do not grow linearly with code-block sizes. Codes that have this minimum-distance property exhibit very low error floors. Examples of such codes include regular LDPC codes with variable degrees of at least 3. Unfortunately, the decoding thresholds of regular LDPC codes are high. Hence, there is a need for LDPC codes characterized by both low decoding thresholds and, in order to obtain acceptably low error floors, minimum Hamming distances that are proportional to code-block sizes. The present codes were developed to satisfy this need. The minimum Hamming distances of the present codes have been shown, through consideration of ensemble-average weight enumerators, to be proportional to code block sizes. As in the cases of irregular ensembles, the properties of these codes are sensitive to the proportion of degree-2 variable nodes. A code having too few such nodes tends to have an iterative decoding threshold that is far from the capacity threshold. A code having too many such nodes tends not to exhibit a minimum distance that is proportional to block size. Results of computational simulations have shown that the decoding thresholds of codes of the present type are lower than those of regular LDPC codes. Included in the simulations were a few examples from a family of codes characterized by rates ranging from low to high and by thresholds that adhere closely to their respective channel capacity thresholds; the simulation results from these examples showed that the codes in question have low

  8. The decrease in yield strength in NiAl due to hydrostatic pressure

    Science.gov (United States)

    Margevicius, R. W.; Lewandowski, J. J.; Locci, I.

    1992-01-01

    The decrease in yield strength in NiAl due to hydrostatic pressure is examined via a comparison of the tensile flow behavior in the low strain regime at 0.1 MPa for NiAl which was cast, extruded, and annealed for 2 hr at 827 C in argon and very slowly cooled to room temperature. Pressurization to 1.4 GPa produces a subsequent reduction at 0.1 MP in proportional limit by 40 percent as well as a 25-percent reduction in the 0.2-percent offset yield strength, while pressurization with lower pressures produces a similar reduction, although smaller in magnitude.

  9. Low Pressure Nuclear Thermal Rocket (LPNTR) concept

    International Nuclear Information System (INIS)

    Ramsthaler, J.H.

    1991-01-01

    A background and a description of the low pressure nuclear thermal system are presented. Performance, mission analysis, development, critical issues, and some conclusions are discussed. The following subject areas are covered: LPNTR's inherent advantages in critical NTR requirement; reactor trade studies; reference LPNTR; internal configuration and flow of preliminary LPNTR; particle bed fuel assembly; preliminary LPNTR neutronic study results; multiple LPNTR engine concept; tank and engine configuration for mission analysis; LPNTR reliability potential; LPNTR development program; and LPNTR program costs

  10. Beam profile monitor

    International Nuclear Information System (INIS)

    Krausse, G.J.; Gram, P.A.M.

    1978-05-01

    A system used to monitor secondary beam profiles at the LAMPF Linac for channel tune-up and diagnostics is described. The multiwire proportional chamber design is discussed, and descriptions and drawings of the gate card, the amplifier/multiplexer card, the output amplifier card, and the overall system are given

  11. Low-pressure argon adsorption assessment of micropore connectivities in activated carbons.

    Science.gov (United States)

    Zimny, T; Villieras, F; Finqueneisel, G; Cossarutto, L; Weber, J V

    2006-01-01

    Low-pressure argon adsorption has been used to study the energetic distribution of microporous activated carbons differing by their burn-off. The collected isotherms were analyzed using the derivative isotherm summation method. Some oscillations on the experimental curves for very low partial pressures were detected. The results are analyzed and discussed according to the literature and could be attributed to local overheating caused by spontaneous mass transfer of argon through constrictions between former pores and the new opening pore or deadend pores. We used the dynamic character of the experimental method and mainly the discrepancy of the quasi-equilibrium state to deduce key parameters related to the porosity topology.

  12. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong; Mulle, Matthieu; Ventura, Isaac Aguilar; Lubineau, Gilles

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube

  13. Measurements for the radiation spectra of fast Z-pinches produced at compression of multi-wire arrays on the 'Angara-5-1' facility

    International Nuclear Information System (INIS)

    Bolkhovitinov, E.A.; Rupasov, A.A.; Shikanov, A.S.; Fedulov, M.V.; Grabovsky, E.V.; Gritsuk, A.N.; Oleinik, G.M.; Volkov, G.S.

    2010-01-01

    Complete text of publication follows. The measurements results on the radiation spectra of fast z-pinches produced at compression of cylindrical multi-wire tungsten and aluminum arrays in the experiments on a high-current 'Angara-5-1' facility are presented. Cylindrical multi-wire arrays has linear mass 200-400 μg/cm and the initial diameter 12-20 mm. The pinch current was about 3 MA with pulse duration of 140 ns and peak power 3 TW. The radiation spectra are measured within the range of 50-900 eV quanta by a spectrometer with transmission diffraction grating, where the radiation is recorded on the UF-4 X-ray film. An electromagnetic curtain shutter was used to protect the transmission grating from fast microparticles produced by the erosion of high-voltage electrodes. The radiation spectrum of 1-3 keV quanta was recorded by a convex crystal wide-range spectrometer. Total yield of the radiation was measured by a thermocouple calorimeter. The main part of the tungsten plasma radiative energy proves to correspond to the quasi-continuous spectrum within the range of 80-300 eV quanta. Measurements of the tungsten plasma radiation spectrum with spatial resolution by a pinch radius have shown that the effective transversal size (diameter) of the pinch as not higher than 1 mm. In the case of aluminum plasma an intensive linear radiation of the [H]- and [He]-like ions have been recorded along with a continuous and linear radiation of the [Li]- and [Be]-like ions with the range of 100-300 eV quanta. Spectral measurements of the aluminum plasma radiation with spatial resolution by the pinch radius have shown that the effective transversal size (diameter) of the pinch is around the value of 1.5 mm. Within the framework of the stationary collisional-radiative model, in respect of the [H]- and [He]-like ion spectral lines relative intensities, the parameters of the aluminum plasma pinch, namely, the electron temperature T e ∼ 550 eV and electron density n e ∼ 3 x 10 20 cm

  14. Thermal applications of low-pressure diamond

    International Nuclear Information System (INIS)

    Haubner, R.; Lux, B.

    1997-01-01

    During the last decade several applications of low-pressure diamond were developed. Main products are diamond heat-spreaders using its high thermal conductivity, diamond windows with their high transparency over a wide range of wavelengths and wear resistant tool coatings because of diamonds superhardness. A short description of the most efficient diamond deposition methods (microwave, DC-glow discharge, plasma-jet and arc discharge) is given. The production and applications of diamond layers with high thermal conductivity will be described. Problems of reproducibility of diamond deposition, the influence of impurities, the heat conductivity in electronic packages, reliability and economical mass production will be discussed. (author)

  15. Pressure ulcers in palliative ward patients: hyponatremia and low blood pressure as indicators of risk.

    Science.gov (United States)

    Sternal, Danuta; Wilczyński, Krzysztof; Szewieczek, Jan

    2017-01-01

    Prevention strategies for pressure ulcer formation remain critical in patients with an advanced illness. We analyzed factors associated with the development of pressure ulcers in patients hospitalized in a palliative care ward setting. This study was a retrospective analysis of 329 consecutive patients with a mean age (± standard deviation) of 70.4±11.8 years (range: 30-96 years, median 70.0 years; 55.3% women), who were admitted to the Palliative Care Department between July 2012 and May 2014. Patients were hospitalized for mean of 24.8±31.4 days (1-310 days, median 14 days). A total of 256 patients (77.8%) died in the ward and 73 patients (22.2%) were discharged. Two hundred and six patients (62.6%) did not develop pressure ulcers during their stay in the ward, 84 patients (25.5%) were admitted with pressure ulcers, and 39 patients (11.9%) developed pressure ulcers in the ward. Four factors assessed at admission appear to predict the development of pressure ulcers in the multivariate logistic regression model: Waterlow score (odds ratio [OR] =1.140, 95% confidence interval [CI] =1.057-1.229, P =0.001), transfer from other hospital wards (OR =2.938, 95% CI =1.339-6.448, P =0.007), hemoglobin level (OR =0.814, 95% CI =0.693-0.956, P =0.012), and systolic blood pressure (OR =0.976, 95% CI =0.955-0.997, P =0.023). Five other factors assessed during hospitalization appear to be associated with pressure ulcer development: mean evening body temperature (OR =3.830, 95% CI =1.729-8.486, P =0.001), mean Waterlow score (OR =1.194, 95% CI =1.092-1.306, P pressure (OR =0.956, 95% CI =0.929-0.984, P =0.003), and the lowest recorded hemoglobin level (OR =0.803, 95% CI =0.672-0.960, P =0.016). Hyponatremia and low blood pressure may contribute to the formation of pressure ulcers in patients with an advanced illness.

  16. A low pressure filter system for new containment concepts

    Energy Technology Data Exchange (ETDEWEB)

    Dillmann, H.G.; Pasler, H. [Kernforschungszentrum Karlsruhe GmbH Laboratorium fuer Isotopentechnik, Karlsruhe (Germany)

    1995-02-01

    It is demonstrated that after severe accidents the decay heat can be removed in a passive mode in a convective flow, i.e. without needing a fan. The filter components with sufficiently low pressure drop values which are required for this purpose will be described and the results indicated.

  17. All solution-processed micro-structured flexible electrodes for low-cost light-emitting pressure sensors fabrication.

    Science.gov (United States)

    Shimotsu, Rie; Takumi, Takahiro; Vohra, Varun

    2017-07-31

    Recent studies have demonstrated the advantage of developing pressure-sensitive devices with light-emitting properties for direct visualization of pressure distribution, potential application to next generation touch panels and human-machine interfaces. To ensure that this technology is available to everyone, its production cost should be kept as low as possible. Here, simple device concepts, namely, pressure sensitive flexible hybrid electrodes and OLED architecture, are used to produce low-cost resistive or light-emitting pressure sensors. Additionally, integrating solution-processed self-assembled micro-structures into the flexible hybrid electrodes composed of an elastomer and conductive materials results in enhanced device performances either in terms of pressure or spatial distribution sensitivity. For instance, based on the pressure applied, the measured values for the resistances of pressure sensors range from a few MΩ down to 500 Ω. On the other hand, unlike their evaporated equivalents, the combination of solution-processed flexible electrodes with an inverted OLED architectures display bright green emission when a pressure over 200 kPa is applied. At a bias of 3 V, their luminance can be tuned by applying a higher pressure of 500 kPa. Consequently, features such as fingernails and fingertips can be clearly distinguished from one another in these long-lasting low-cost devices.

  18. Gas-multiplication factor of a proportional counter operated at low temperature described with the Diethorn, Rose-Korff and townsend expressions

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Kazuko; Nakanishi, Akio; Kobayashi, Takayuki [Shiga Univ. of Medical Science, Otsu (Japan)

    1996-07-01

    In the present work, the gas-multiplication factor is expressed with the Rose-Korff and Townsend methods as well as with the Diethorn method. A proportional counter with helium or neon works only at low temperature. This is discussed in terms of the number of electrons emitted when an ion is neutralized at the cathode of the counter. (J.P.N.)

  19. Prevalence of pre-high blood pressure and high blood pressure among non-overweight children and adolescents using international blood pressure references in developed regions in China.

    Science.gov (United States)

    Tian, Changwei; Xu, Shuang; Wang, Hua; Wang, Wenming; Shen, Hui

    2017-09-01

    There is a lack of data on the prevalence of pre-high blood pressure (PreHBP) and high blood pressure (HBP), based on recent international blood pressure references, in non-overweight children and adolescents. To describe the prevalence of PreHBP and HBP in non-overweight children and adolescents in developed regions of China. In total, 588 097 non-overweight children and adolescents aged 6-17 years from the National Surveys on Chinese Students' Constitution and Health in 2015 were included. The prevalence of PreHBP was 13.41% and subjects in urban areas had a higher prevalence of PreHBP (14.14%) than those in rural areas (12.92%). Subjects in regions with a high (13.56%) or moderate (13.61%) socioeconomic status showed a higher prevalence of PreHBP than those in regions with a relatively low socioeconomic status (12.76%). A similar pattern was found for the prevalence of HBP, and the prevalence of HBP was 18.25% for all participants, 20.55% for subjects in urban areas, 16.71% in rural areas, 18.76% in high socioeconomic areas, 18.62% in moderate socioeconomic areas and 16.70% in relatively low socioeconomic areas. A large proportion of non-overweight children and adolescents had elevated blood pressure and there were urban-rural and socioeconomic disparities in the prevalence of elevated blood pressure.

  20. First results of a simultaneous measurement of tritium and 14C in an ultra-low-background proportional counter for environmental sources of methane

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Emily K.; Aalseth, Craig E.; Day, Anthony R.; Hoppe, Eric W.; Keillor, Martin E.; Moran, James J.; Panisko, Mark E.; Seifert, Allen; Tatishvili, Gocha; Williams, Richard M.

    2016-02-01

    Abstract Simultaneous measurement of tritium and 14C would provide an added tool for tracing organic compounds through environmental systems and is possible via beta energy spectroscopy of sample-derived methane in internal-source gas proportional counters. Since the mid-1960’s atmospheric tritium and 14C have fallen dramatically as the isotopic injections from above-ground nuclear testing have been diluted into the ocean and biosphere. In this work, the feasibility of simultaneous tritium and 14C measurements via proportional counters is revisited in light of significant changes in both the atmospheric and biosphere isotopics and the development of new ultra-low-background gas proportional counting capabilities for small samples (roughly 50 cc methane). A Geant4 Monte Carlo model of a Pacific Northwest National Laboratory (PNNL) proportional counter response to tritium and 14C is used to analyze small samples of two different methane sources to illustrate the range of applicability of contemporary simultaneous measurements and their limitations. Because the two methane sources examined were not sample size limited, we could compare the small-sample measurements performed at PNNL with analysis of larger samples performed at a commercial laboratory. The dual-isotope simultaneous measurement is well matched for methane samples that are atmospheric or have an elevated source of tritium (i.e. landfill gas). For samples with low/modern tritium isotopics (rainwater), commercial separation and counting is a better fit.

  1. Investigating Low-Cost Optical Spectroscopy for Sensing Pressure Ulcers

    Science.gov (United States)

    Mirchandani, Smruti Suresh

    Diffuse Reflectance Spectroscopy has been used widely to characterize tissue properties for diagnostic and therapeutic applications. This thesis focuses on the use of spectroscopy for early pressure ulcer detection. The most common early diagnosis technique for pressure ulcers is a blanch test. A major issue with a blanch test is that it is purely visual and cannot be visibly observed on dark skinned individuals. Studies have already proven that spectroscopy can be used to detect blanch response in skin across light and dark skinned individuals. The portable reflectance spectroscopy setup showed that pressure changes to the skin can be detected spectroscopically. Some work on an iPhone based spectrometer was also done to have a low-cost spectroscopy alternative to the usual DRS equipment. This study failed to develop an iPhone based spectrometer but various factors that can be changed to better this research have been mentioned in this thesis.

  2. Wire chamber degradation at the Argonne ZGS

    International Nuclear Information System (INIS)

    Haberichter, W.; Spinka, H.

    1986-01-01

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM

  3. Hardware processors for pattern recognition tasks in experiments with wire chambers

    International Nuclear Information System (INIS)

    Verkerk, C.

    1975-01-01

    Hardware processors for pattern recognition tasks in experiments with multiwire proportional chambers or drift chambers are described. They vary from simple ones used for deciding in real time if particle trajectories are straight to complex ones for recognition of curved tracks. Schematics and block-diagrams of different processors are shown

  4. Characteristics of the detection system of the Orsay Synchrocyclotron achromatic channel: study and determination

    International Nuclear Information System (INIS)

    Ovazza, D.

    1978-01-01

    Once the multiwire proportional chamber working principle studied it is shown that the avalanche must not necessary surround the anode wire. Geometrical characteristics of the MWPC used behind the 'Montpellier' spectrometer of the IPN synchrocyclotron, are determined from an evaluation of the induced charges on the cathode and anode wires [fr

  5. Experimental and theoretical investigations on condensation heat transfer at very low pressure to improve power plant efficiency

    International Nuclear Information System (INIS)

    Berrichon, J.D.; Louahlia-Gualous, H.; Bandelier, Ph.; Bariteau, N.

    2014-01-01

    Highlights: • Theoretical model for condensation heat transfer at very low pressure is developed using only one iterative loop. • Experimental results on steam and air steam condensation heat transfer at very low pressure are presented. • The developed model gives the good predictions for local condensation heat transfer at low pressure. • A maximal deterioration of 50% in condensation heat transfer is obtained at low pressure for air fraction of 4%. • A new correlation including effect of a wavy film surface for steam condensation at low pressure is suggested. - Abstract: This paper presents experimental investigation on the influence of very low pressure on local and average condensation heat transfer in a vertical tube. Furthermore, this paper develops an analytical study for film condensation heat transfer coefficient in the presence of non-condensable gas inside a vertical tube. The condensate film thickness is calculated for each location in a tube using mass and heat transfer analogy. The effects of interfacial shear stress and waves on condensate film surface are included in the model. The comparative studies show that the present model well predicts the experimental data of Khun et al. [1]for local condensation of steam air mixture at high pressure. Different correlations defined for condensation heat transfer are evaluated. It is found that the correlations of Cavallini and Zecchin [2] and Shah [3] are the closest to the calculated steam condensation local heat transfer coefficient. The model gives a satisfactory accuracy with the experimental results for condensation heat transfer at very low pressure. The mean deviation between the predictions of the theoretical model with the measurements for pure saturated vapor is 12%. Experimental data show that the increase of air fraction to 4% deteriorates condensation heat transfer at low pressure up to 50%

  6. A Plasma Focus operated at a very low pressure range

    International Nuclear Information System (INIS)

    Bruzzone, H.; Grondona, D.; Kelly, H.; Marquez, A.

    1990-01-01

    Several characteristics of the neutron production and the hard X-ray emission from a Plasma Focus device operating at 30 kV (6 kV of stored energy) and at an unusually low pressure range are presented. (Author)

  7. Association of low blood pressure with suicidal ideation: a cross-sectional study of 10,708 adults with normal or low blood pressure in Korea.

    Science.gov (United States)

    Joung, Kyung-In; Cho, Sung-Il

    2018-03-01

    Whether constitutional low blood pressure (BP) causes substantive health problems has been controversial, and subjects with hypotension exhibit a range of symptoms, from mild typical conditions such as tiredness and dizziness to more specific psychological conditions and even cognitive disorders. This study investigated whether low BP is associated with suicidal ideation in the general population. Four years of data from the 2010-2013 Korean National Health and Nutrition Examination Survey were used. Among the 23,163 participants, aged 19-101 years, 10,708 with normal or low BP were included in the analysis of the association between low BP and suicidal ideation. The criterion used for low BP was systolic BP (SBP) low BP were SBP Low SBP showed an association with suicidal ideation in the general Korean population. The association was significant for low BP, defined as a SBP low BP increased in strictness.

  8. Multi-stage versus single-stage inflation and deflation cycle for alternating low pressure air mattresses to prevent pressure ulcers in hospitalised patients: a randomised-controlled clinical trial.

    Science.gov (United States)

    Demarré, L; Beeckman, D; Vanderwee, K; Defloor, T; Grypdonck, M; Verhaeghe, S

    2012-04-01

    The duration and the amount of pressure and shear must be reduced in order to minimize the risk of pressure ulcer development. Alternating low pressure air mattresses with multi-stage inflation and deflation cycle of the air cells have been developed to relieve pressure by sequentially inflating and deflating the air cells. Evidence about the effectiveness of this type of mattress in clinical practice is lacking. This study aimed to compare the effectiveness of an alternating low pressure air mattress that has a standard single-stage inflation and deflation cycle of the air cells with an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. A randomised controlled trial was performed in a convenience sample of 25 wards in five hospitals in Belgium. In total, 610 patients were included and randomly assigned to the experimental group (n=298) or the control group (n=312). In the experimental group, patients were allocated to an alternating low pressure air mattress with multi-stage inflation and deflation cycle of the air cells. In the control group, patients were allocated to an alternating low pressure air mattress with a standard single-stage inflation and deflation cycle of the air cells. The outcome was defined as cumulative pressure ulcer incidence (Grade II-IV). An intention-to-treat analysis was performed. There was no significant difference in cumulative pressure ulcer incidence (Grade II-IV) between both groups (Exp.=5.7%, Contr.=5.8%, p=0.97). When patients developed a pressure ulcer, the median time was 5.0 days in the experimental group (IQR=3.0-8.5) and 8.0 days in the control group (IQR=3.0-8.5) (Mann-Whitney U-test=113, p=0.182). The probability to remain pressure ulcer free during the observation period in this trial did not differ significantly between the experimental group and the control group (log-rank χ(2)=0.013, df=1, p=0.911). An alternating low pressure air mattress with multi-stage inflation

  9. Proportional reasoning

    DEFF Research Database (Denmark)

    Dole, Shelley; Hilton, Annette; Hilton, Geoff

    2015-01-01

    Proportional reasoning is widely acknowledged as a key to success in school mathematics, yet students’ continual difficulties with proportion-related tasks are well documented. This paper draws on a large research study that aimed to support 4th to 9th grade teachers to design and implement tasks...

  10. Reduction of degraded events in miniaturized proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, R.; Kirsten, T. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1991-11-15

    A method to reduce the number of degraded events in miniaturized proportional counters is described. A shaping of the outer cathode leads to a more uniform gas gain along the counter axis. The method is useful in situations in which the total number of decay events is very low. The effects leading to degraded events are studied theoretically and experimentally. The usefulness of the method is demonstrated by using it for the proportional counter of the GALLEX solar neutrino experiment. (orig.).

  11. Critical heat flux data in a vertical tube at low and medium pressures

    Energy Technology Data Exchange (ETDEWEB)

    Teyssedou, A [Institut de Genie Nucleaire, Ecole Polytechnique, C.P. 6079, succ. Centre-ville, Montreal, Quebec H3C 3A7 (Canada); Olekhnowitch, A [Institut de Genie Nucleaire, Ecole Polytechnique, C.P. 6079, succ. Centre-ville, Montreal, Quebec H3C 3A7 (Canada); Tapucu, A [Institut de Genie Nucleaire, Ecole Polytechnique, C.P. 6079, succ. Centre-ville, Montreal, Quebec H3C 3A7 (Canada); Champagne, P [Institut de Genie Nucleaire, Ecole Polytechnique, C.P. 6079, succ. Centre-ville, Montreal, Quebec H3C 3A7 (Canada); Groeneveld, D [Chalk River Laboratories, AECL Research, Chalk River (Canada)

    1994-09-01

    AECL Research and Ecole Polytechnique have been cooperating on the validation of the critical heat flux (CHF) look-up table (D.C. Groeneveld et al., Heat Transfer Eng. 7(1-2) (1986) 46-62). For low and medium pressures the values in the table have been obtained by extrapolation and curve fitting; therefore, errors could be expected. To reduce these possible extrapolation errors, CHF experiments are being carried out in water cooled 8mm internal diameter (ID) tubes, at conditions where the data are scarce. This paper presents some of the experimental CHF data obtained for vertical up flow in an 8mm ID test section, for a wide range of exit qualities (5-70%) and the exit pressure ranging from 5 to 30bar. The experiments were carried out for heated lengths of 0.75, 1, 1.4 and 1.8m. In general, the collected data show parametric trends similar to those described in the open literature. However, it was observed that for low pressure conditions CHF depends on the heated length; this dependence begins to disappear for exit pressure of about 30bar. The CHF data have also been compared with predictions of well-known correlations (L. Biasi et al., Energia Nucl. 14(9) (1967) 530-536; R. Bowring, Br. Report AEEW-R789, Winfrith, UK, 1972; Y. Khatto and H. Ohno, Int. J. Heat Mass Transfer 27 (1984) 1641-1648) and those of the look-up table given by Groeneveld et al. For low pressures and low mass fluxes the look-up table seems to yield better predictions of the CHF than the correlations. However, for medium pressures and mass fluxes the correlations perform better than the look-up table; among those tested, Katto and Ohno's correlation gives the best results. ((orig.))

  12. Post-dryout heat transfer and entrained droplet sizes at low pressure and low flow conditions

    International Nuclear Information System (INIS)

    Jeong, H.Y.; No, H.C.

    1997-01-01

    The entrainment mechanisms and the entrained droplet sizes with relation to the flow regimes are investigated. Through the analysis of many experimental post-dryout data, it is shown that the most probable flow regime near dryout or quench front is not annular flow but churn-turbulent flow when the mass flux is low. A correlation describing the initial droplet size just after the CHF position at low mass flux is suggested through regression analysis. The history-dependent post-dryout model of Varone and Rohsenow replaced by the Webb-Chen model for wall-vapor heat transfer is used as a reference model in the analysis. In the post-dryout region at low pressure and low flow, it is found that the suggested one-dimensional mechanistic model is not applicable when the vapor superficial velocity is very low. This is explained by the change of main entrainment mechanism with the change of flow regime. In bubbly or slug flow a number of tiny droplets generated from bubble burst become important in the heat transfer after dryout. Therefore, the suggested correlation is valid only in the churn-turbulent flow regime (j g * = 0.5∼4.5). It is also suggested that the droplet size generated from the churn-turbulent surface is dependent not only on the pressure but also on the vapor velocity. It turns out that the present model can predict the measured cladding and vapor temperatures within 20% and 25%, respectively

  13. Aluminum oxide films deposited in low pressure conditions by reactive pulsed dc magnetron sputtering

    CERN Document Server

    Seino, T

    2002-01-01

    The reactive pulsed dc sputtering technique is widely used for the deposition of oxide films. The operating pressure for sputtering is commonly above 0.13 Pa. In this study, however, aluminum oxide (alumina) films were deposited at operating pressures from 0.06 to 0.4 Pa using a sputtering system equipped with a scanning magnetron cathode and a pulsed dc power supply. The pulsed dc power was found to be useful not only to reduce arcing, but also to sustain the discharge at low pressure. The electrical breakdown field, intrinsic stress, O/Al ratio, refractive index, and surface roughness were investigated. Both a low intrinsic stress and an O/Al ratio around the stoichiometry were required to get the film having a high breakdown field. A low operating pressure of 0.1 Pa was found to provide the necessary stress and O/Al ratio targets. A 50-nm-thick alumina film having a maximum breakdown field of 7.4 MV/cm was obtained.

  14. Formation Mechanism of Surface Crack in Low Pressure Casting of A360 Alloy

    Science.gov (United States)

    Liu, Shan-Guang; Cao, Fu-Yang; Ying, Tao; Zhao, Xin-Yi; Liu, Jing-Shun; Shen, Hong-Xian; Guo, Shu; Sun, Jian-Fei

    2017-12-01

    A surface crack defect is normally found in low pressure castings of Al alloy with a sudden contraction structure. To further understand the formation mechanism of the defect, the mold filling process is simulated by a two-phase flow model. The experimental results indicate that the main reason for the defect deformation is the mismatching between the height of liquid surface in the mold and pressure in the crucible. In the case of filling, a sudden contraction structure with an area ratio smaller than 0.5 is obtained, and the velocity of the liquid front increases dramatically with the influence of inertia. Meanwhile, the pressurizing speed in the crucible remains unchanged, resulting in the pressure not being able to support the height of the liquid level. Then the liquid metal flows back to the crucible and forms a relatively thin layer solidification shell on the mold wall. With the increasing pressure in the crucible, the liquid level rises again, engulfing the shell and leading to a surface crack. As the filling velocity is characterized by the damping oscillations, surface cracks will form at different heights. The results shed light on designing a suitable pressurizing speed for the low pressure casting process.

  15. Heavy particle detection characteristics of an MWPC operating at low (1 <= p <= 30 mbar) gas pressures

    International Nuclear Information System (INIS)

    Moeller, G.; Presser, G.; Staehler, J.

    1981-01-01

    Pulse heights, timing properties and detection efficiencies of an MWPC were measured with 5.5 MeV alpha particles for different counting gases at low pressures. The pulse heights show a striking nonmonotonic dependence on the gas pressure that can be explained by a simple model of the amplification process at high reduced electric fields. The consequences of the observed pressure dependence of pulse heights for the detection of heavy ions with low pressure MWPCs are discussed. (orig.)

  16. Aperiodic pressure pulsation under non optimal hydraulic turbine regimes at low swirl number

    Science.gov (United States)

    Skripkin, S. G.; Tsoy, M. A.; Kuibin, P. A.; Shtork, S. I.

    2017-09-01

    Off-design operating conditions of hydraulic turbines is hindered by pressure fluctuations in the draft tube of the turbine. A precessing helical vortex rope develops, which imperils the mechanical structure and limits the operation flexibility of hydropower station. Understanding of the underlying instabilities of precessing vortex rope at low swirl number is incomplete. In this paper flow regimes with different residual swirl is analysed, particular attention is paid to the regime with a small swirl parameter. Study defines upper and low boundaries of regime where aperiodic pressure surge is observed. Flow field at the runner exit is investigated by Laser Doppler Velocimetry and high-speed visualizations, which are complemented draft tube wall pressure measurements.

  17. On designing low pressure loss working spaces for a planar Stirling micromachine

    Science.gov (United States)

    Hachey, M.-A.; Léveillé, É.; Fréchette, L. G.; Formosa, F.

    2015-12-01

    In this paper, research was undertaken with the objective to design low pressure loss working spaces for a Stirling cycle micro heat engine operating from low temperature waste heat. This planar free-piston heat engine is anticipated to operate at the kHz level with mm3 displacement. Given the resonant nature of the free-piston configuration, the complexity of its working gas’ flow geometry and its projected high operating frequency, flow analysis is relatively complex. Design considerations were thus based on fast prototyping and experimentation. Results show that geometrical features, such as a sharp 90° corner between the regenerator and working spaces, are strong contributors to pressure losses. This research culminated into a promising revised working space configuration for engine start-up, as it considerably reduced total pressure losses, more than 80% at Re = 700, from the original design.

  18. Improvement of the RELAP5 subcooled boiling model for low pressure conditions

    International Nuclear Information System (INIS)

    Koncar, B.; Mavko, B.

    2000-01-01

    The RELAP5/MOD3.2.2 Gamma code was assessed against low pressure subcooled boiling experiments performed by Zeitoun and Shoukri [1] in a vertical annulus. The predictions of subcooled boiling bubbly flow showed that the present version of the RELAP5 code underestimates the void fraction growth along the tube. To improve the void fraction prediction at low pressure conditions a set of model changes is proposed, which includes modifications of bubbly-slug transition criterion, drift-flux model, interphase heat transfer coefficient and wall evaporation modeling. The improved experiment predictions with the modified RELAP5 code are presented and analysed. (author)

  19. Ultra-low-pressure sputtering to improve exchange bias and tune linear ranges in spin valves

    Energy Technology Data Exchange (ETDEWEB)

    Tang, XiaoLi, E-mail: tangtang1227@163.com; Yu, You; Liu, Ru; Su, Hua; Zhang, HuaiWu; Zhong, ZhiYong; Jing, YuLan

    2017-05-01

    A series of CoFe/IrMn exchange bilayers was grown by DC-sputtering at different ultra-low argon pressures ranging from 0.008 to 0.1 Pa. This pressure range was one to two orders lower than the normal sputtering pressure. Results revealed that the exchange bias increased from 140 to 250 Oe in CoFe(10 nm)/IrMn (15 nm) bilayers of fixed thickness because of the improved crystalline structure and morphological uniformity of films. Since ferromagnetic /antiferromagnetic (FM/AF) bilayers are always used in linear magnetic sensors as detection layers, the varying exchange bias can successfully achieve tunable linear range in a crossed pinning spin valve. The linear range could be adjustable from −80 Oe – +80 Oe to −150 Oe – +150 Oe on the basis of giant magnetoresistance responses. Therefore, this method provides a simple method to tune the operating range of magnetic field sensors. - Highlights: • Increasing exchange bias was achieved in bilayer at ultra-low-pressure sputtering. • The low void density and smooth surface were achieved in low pressure. • Varying exchange bias achieved tunable linear range in spin valve.

  20. Non-invasive multiwavelength photoplethysmography under low partial pressure of oxygen.

    Science.gov (United States)

    Fang, Yung Chieh; Tai, Cheng-Chi

    2016-08-01

    A reduction in partial pressure of oxygen in the environment may be caused by a gain in altitude, which reduces the atmospheric pressure; it may also be caused by the carbon dioxide generated from breathing in an enclosed space. Does inhaling oxygen of lower partial pressure affect the oxygen-carrying function of haemoglobin in vivo? This study uses non-invasive multiwavelength photoplethysmography to measure the effects that inhaling this type of oxygen can have on the plethysmography of the appendages of the body (fingertips). The results indicate that under low partial pressure of oxygen, be it the result of a gain in carbon dioxide concentration or altitude, the change in visible light absorption is the biggest for short wavelengths (approximately 620 or 640 nm) near deoxyhaemoglobin, which has higher absorption coefficient. Moreover, increasing carbon dioxide concentration from 5000 to 10,000 ppm doubly reduces the absorption rate of these short wavelengths.

  1. High pressure, low pressure and hot water heating systems in hospitals. Hochdruck-, Niederdruck- und Warmwasserheizungsanlagen im Krankenhaus

    Energy Technology Data Exchange (ETDEWEB)

    Riedle, K [H. Riedle GmbH, Wiesbaden (Germany)

    1994-07-01

    In hospital nowadays the limitation of the use of steam boilers and their direct supply network to the possible minimum is aimed at when the heating system is exchanged or retrofitted. Independent of the fact whether high pressure or low pressure steam or hot water is used the optimum water treatment should be carried out with a minimum of chemical substances. Here hydroquinone, neutralizing amines, carbohydrazide, sodium sulphite and tannins can be used. The dimensioning of hot water heating circuits is shown with examples. (BWI)

  2. Liquefaction of Warukin Formation Coal, Barito Basin, South Kalimantan on Low Pressure and Low Temperature

    Directory of Open Access Journals (Sweden)

    Edy Nursanto

    2013-06-01

    Full Text Available Research focusing on the quality of coal in Warukin Formation has been conducted in coal outcrops located on Tabalong area, particularly in 3 coal seams, namely Wara 120 which consists of low rank coal (lignite. Meanwhile, coals in seam Tutupan 210 and Paringin 712 are medium rank coal (sub-bituminous. Coal liquefaction is conducted in an autoclave on low pressure and temperature. Pressure during the process is 14 psi and temperature is 120oC. Catalyst used are alumina, hydrogen donor NaOH and water solvent. Liquefaction is conducted in three times variables of 30 minutes, 60 minutes and 90 minutes. This process shows following yield : Wara seam 120: 25.37% - 51.27%; Tutupan seam 210: 3.02%-15.45% and seam Paringin 712:1.99%-11.95%. The average result of yield shows that coals in seam Wara has higher yield conversion than coals in seam Tutupan and Paringin.

  3. LOW PRESSURE ULTRAVEIOLET STUDIES FOR INACTIVATION OF GIARDIA MURIS CYSTS

    Science.gov (United States)

    Cysts of Giardia muris were inactivated using a low pressure ultravolet (UV) light source. Cyst viability was detemined by both in vitro excystation and animal infectivity. Cyst doeses were counted using a flow cytometer for the animal infectivity experiments. Using in vitro excy...

  4. The Pressure and Magnetic Flux Density Analysis of Helical-Type DC Electromagnetic Pump

    International Nuclear Information System (INIS)

    Lee, Geun Hyeong; Kim, Hee Reyoung

    2016-01-01

    The developed pressure was made by only electromagnetic force eliminating probability of impurities contact, therefore the high reactivity materials such as alkali were best match to electromagnetic pump. The heavy ion accelerator facility by Rare Isotope Science Project (RISP) in Korea is trying to construct accelerator using liquid lithium for high efficiency of acceleration by decreasing charge state. The helical-type DC electromagnetic pump was employed to make a charge stripper that decrease charge state of heavy ion. The specification of electromagnetic pump was developed pressure of 15 bar with flowrate of 6 cc/s in the condition of 200℃. The pressure of DC electromagnetic pump was analyzed in the aspects of current and number of duct turns. The developed pressure was almost proportional to input current because relatively low flowrate made negligible of the electromotive force and hydraulic pressure drop. The pressure and magnetic flux density of helical-type DC electromagnetic pump were analyzed. The pressure was proportion to input current and number of duct turns, and magnetic flux density was higher when ferromagnet was applied at electromagnetic pump. It seems that number of duct turns could be increase and ferromagnet could be applied in order to increase pressure of DC electromagnetic pump with constant input current

  5. A general view of the ISR intersection region I-4

    CERN Multimedia

    1983-01-01

    The photo was taken when there was a changeover of experiments using the SFM detector. Obe of the rare moments when the gap of the SFM and a few of the multiwire proportional chambers which make the heart of the detector system could be seen (Annual Report 1983 p. 128 , Fig. 14).

  6. An extended parametrization of gas amplification in proportional wire chambers

    International Nuclear Information System (INIS)

    Beingessner, S.P.; Carnegie, R.K.; Hargrove, C.K.

    1987-01-01

    It is normally assumed that the gas amplification in proportional chambers is a function of Townsend's first ionization coefficient, α, and that α is a function of the anode surface electric field only. Experimental measurements are presented demonstrating the breakdown of the latter assumption for electric fields, X, greater than about 150 V/cm/Torr on the anode wire surface for a gas mixture of 80/20 argon/methane. For larger values of X, the parametrization of the proportional gas gain data requires an additional term related to the gradient of the electric field near the wire. This extended gain parametrization remains valid until the onset of nonproportional contributions such as positive ion space charge saturation effects. Furthermore, deviations of the data from this parametrization are used to measure the onset of these space charge effects. A simple scaling dependence of the gain data on the product of pressure and wire radius over the whole proportional range is also demonstrated. (orig.)

  7. Weak interactions between water and clathrate-forming gases at low pressures

    Energy Technology Data Exchange (ETDEWEB)

    Thurmer, Konrad; Yuan, Chunqing; Kimmel, Gregory A.; Kay, Bruce D.; Smith, R. Scott

    2015-11-01

    Using scanning probe microscopy and temperature programed desorption we examined the interaction between water and two common clathrate-forming gases, methane and isobutane, at low temperature and low pressure. Water co-deposited with up to 10-1 mbar methane or 10-5 mbar isobutane at 140 K onto a Pt(111) substrate yielded pure crystalline ice, i.e., the exposure to up to ~107 gas molecules for each deposited water molecule did not have any detectable effect on the growing films. Exposing metastable, less than 2 molecular layers thick, water films to 10-5 mbar methane does not alter their morphology, suggesting that the presence of the Pt(111) surface is not a strong driver for hydrate formation. This weak water-gas interaction at low pressures is supported by our thermal desorption measurements from amorphous solid water and crystalline ice where 1 ML of methane desorbs near ~43 K and isobutane desorbs near ~100 K. Similar desorption temperatures were observed for desorption from amorphous solid water.

  8. Numerical modeling and investigation of two-phase reactive flow in a high-low pressure chambers system

    International Nuclear Information System (INIS)

    Cheng, Cheng; Zhang, Xiaobing

    2016-01-01

    Highlights: • A novel two-dimensional two-phase flow model is established for the high-low pressure chambers system. • A strong packing of particles is observed at the projectile base and will cause the pressure to rise faster. • Different length–diameter ratios can affect the flow behavior through the vent-holes obviously. • The muzzle velocity decreases with the length–diameter ratio of the high-pressure chamber. - Abstract: A high-low pressure chambers system is proposed to meet the demands of low launch acceleration for informative equipment in many special fields such as Aeronautics, Astronautics and Weaponry. A two-dimensional two-phase flow numerical model is established to describe the complex physical process based on a modified two-fluid theory, which takes into account gas production, interphase drag, intergranular stress, and heat transfer between two phases. In order to reduce the computational cost, the parameters in the high-pressure chamber at the instant the vent-holes open are calculated by the zero-dimensional model as the initial conditions for the two-phase flow simulation in the high-low pressure chambers system. The simulation results reveal good agreement with the experiments and the launch acceleration of a projectile can be improved by this system. The propellant particles can be tracked clearly in both chambers and a strong packing of particles at the base of projectile will cause the pressure to rise faster than at other areas both in the axis and radial directions. The length–diameter ratio of the high-pressure chamber (a typical multi-dimensional parameter) is investigated. Different length–diameter ratios can affect the maximum pressure drop and the loss of total pressure impulse through the vent-hole, then the muzzle velocity and the launch acceleration of projectiles can be influenced directly. This article puts forward a new prediction tool for the understanding and design of transient processes in high-low pressure

  9. Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring.

    Science.gov (United States)

    Majerus, Steve J A; Garverick, Steven L; Suster, Michael A; Fletter, Paul C; Damaser, Margot S

    2012-06-01

    The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μ A from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session.

  10. Low-pressure degenerate four-wave mixing spectroscopy with flam atomization

    International Nuclear Information System (INIS)

    Nolan, T.G.; Koutny, L.B.; Blazewicz, P.R.; Whitten, W.B.; Ramsey, J.M.

    1988-01-01

    A combination of degenerate four-wave mixing spectroscopy and a low-pressure sampling technique has been studied for isotopic analysis in an air-acetylene flame. Hyperfine spectra of D lines of sodium and several mixtures of lithium isotopes obtained in this way are presented

  11. Wearable and low-stress ambulatory blood pressure monitoring technology for hypertension diagnosis.

    Science.gov (United States)

    Altintas, Ersin; Takoh, Kimiyasu; Ohno, Yuji; Abe, Katsumi; Akagawa, Takeshi; Ariyama, Tetsuri; Kubo, Masahiro; Tsuda, Kenichiro; Tochikubo, Osamu

    2015-01-01

    We propose a highly wearable, upper-arm type, oscillometric-based blood pressure monitoring technology with low-stress. The low-stress is realized by new developments in the hardware and software design. In the hardware design, conventional armband; cuff, is almost halved in volume thanks to a flexible plastic core and a liquid bag which enhances the fitness and pressure uniformity over the arm. Reduced air bag volume enables smaller motor pump size and battery leading to a thinner, more compact and more wearable unified device. In the software design, a new prediction algorithm enabled to apply less stress (and less pain) on arm of the patient. Proof-of-concept experiments on volunteers show a high accuracy on both technologies. This paper mainly introduces hardware developments. The system is promising for less-painful and less-stressful 24-hour blood pressure monitoring in hypertension managements and related healthcare solutions.

  12. The influence of low air pressure on horizontal flame spread over flexible polyurethane foam and correlative smoke productions

    International Nuclear Information System (INIS)

    Tu, Ran; Zeng, Yi; Fang, Jun; Zhang, Yongming

    2016-01-01

    Highlights: • Quasi two-dimensional flame spreading behavior of flexible polyurethane (FPU) foam was investigated. • Theoretical correlation of pressure effects on global burning rate was proposed. • The influence of pressure on plume and ceiling jet temperatures was studied theoretically. • Pressure effects on soot formation and CO concentration were analyzed. - Abstract: Pressure effects on quasi two-dimensional flexible polyurethane (FPU) foam flame spreading behavior, typical product concentrations, and smoke detector responses were investigated by comparative experiments under different ambient pressures of 99.8 kPa (in Hefei) and 66.5 kPa (in Lhasa), respectively. First, significant decreases of flame spreading velocity and burning rate were observed under low pressure condition. Averaged global burning rate was found to be dependent on pressure, with an exponential factor of 4/3 theoretically based on pressure modeling. Second, the maximum temperature at a given position in axial thermal plume showed insensitivity to pressure, yet the maximum temperature in ceiling jet was obviously higher. Third, the low pressure was shown to have no effect on soot particles size distribution by scan electron microscopy (SEM) imaging. However, the soot number concentration decreased with reduced pressure attributed to the much slower soot formation rate under low pressure. This result would further have an interesting influence on the response signals of photoelectric detector and ionization detector. Finally, the pressure effects on variation of CO and O_2 volume concentration were discussed. Considering the relatively small heat release rate for FPU foam selected, the CO concentration in the far-field ceiling jet low under low pressure was found to be lower for the enhanced diffusive effect.

  13. Low-frequency blood pressure oscillations and inotrope treatment failure in premature infants.

    Science.gov (United States)

    Vesoulis, Zachary A; Hao, Jessica; McPherson, Christopher; El Ters, Nathalie M; Mathur, Amit M

    2017-07-01

    The underlying mechanism as to why some hypotensive preterm infants do not respond to inotropic medications remains unclear. For these infants, we hypothesize that impaired vasomotor function is a significant factor and is manifested through a decrease in low-frequency blood pressure variability across regulatory components of vascular tone. Infants born ≤28 wk estimated gestational age underwent prospective recording of mean arterial blood pressure for 72 h after birth. After error correction, root-mean-square spectral power was calculated for each valid 10-min data frame across each of four frequency bands ( B1 , 0.005-0.0095 Hz; B2 , 0.0095-0.02 Hz; B3 , 0.02-0.06 Hz; and B4 , 0.06-0.16) corresponding to different components of vasomotion control. Forty infants (twenty-nine normotensive control and eleven inotrope-exposed) were included with a mean ± SD estimated gestational age of 25.2 ± 1.6 wk and birth weight 790 ± 211 g. 9.7/11.8 Million (82%) data points were error-free and used for analysis. Spectral power across all frequency bands increased with time, although the magnitude was 20% less in the inotrope-exposed infants. A statistically significant increase in spectral power in response to inotrope initiation was noted across all frequency bands. Infants with robust blood pressure response to inotropes had a greater increase compared with those who had limited or no blood pressure response. In this study, hypotensive infants who require inotropes have decreased low-frequency variability at baseline compared with normotensive infants, which increases after inotrope initiation. Low-frequency spectral power does not change for those with inotrope treatment failure, suggesting dysfunctional regulation of vascular tone as a potential mechanism of treatment failure. NEW & NOTEWORTHY In this study, we examine patterns of low-frequency oscillations in blood pressure variability across regulatory components of vascular tone in normotensive and

  14. Heritability of blood pressure traits and the genetic contribution to blood pressure variance explained by four blood-pressure-related genes.

    NARCIS (Netherlands)

    Rijn, M.J. van; Schut, A.F.; Aulchenko, Y.S.; Deinum, J.; Sayed-Tabatabaei, F.A.; Yazdanpanah, M.; Isaacs, A.; Axenovich, T.I.; Zorkoltseva, I.V.; Zillikens, M.C.; Pols, H.A.; Witteman, J.C.; Oostra, B.A.; Duijn, C.M. van

    2007-01-01

    OBJECTIVE: To study the heritability of four blood pressure traits and the proportion of variance explained by four blood-pressure-related genes. METHODS: All participants are members of an extended pedigree from a Dutch genetically isolated population. Heritability and genetic correlations of

  15. Low pressure pain thresholds are associated with, but does not predispose for, low back pain

    DEFF Research Database (Denmark)

    O'Neill, Søren; Kjær, Per; Graven-Nielsen, Thomas

    2011-01-01

    Chronic pain is often associated with hyperalgesia in cross-sectional studies. In the present study, a random cohort of 40-year-old individuals (n = 264) from the general population was assessed for low back pain (LBP) status and pressure pain threshold (PPT), with follow-up assessment 4 and 8......-lasting LBP, those with a low PPT at baseline (lower 10% percentile) had no increased risk of developing LBP (p > 0.05). The findings indicate that PPT decreases as a consequence of long-lasting pain, whereas a low PPT seems not to constitute a separate risk factor for the development of LBP....

  16. Effects of Solvent and Ion Source Pressure on the Analysis of Anabolic Steroids by Low Pressure Photoionization Mass Spectrometry.

    Science.gov (United States)

    Liu, Chengyuan; Zhu, Yanan; Yang, Jiuzhong; Zhao, Wan; Lu, Deen; Pan, Yang

    2017-04-01

    Solvent and ion source pressure were two important factors relating to the photon induced ion-molecule reactions in low pressure photoionization (LPPI). In this work, four anabolic steroids were analyzed by LPPI mass spectrometry. Both the ion species present and their relative abundances could be controlled by switching the solvent and adjusting the ion source pressure. Whereas M •+ , MH + , [M - H 2 O] + , and solvent adducts were observed in positive LPPI, [M - H] - and various oxidation products were abundant in negative LPPI. Changing the solvent greatly affected formation of the ion species in both positive and negative ion modes. The ion intensities of the solvent adduct and oxygen adduct were selectively enhanced when the ion source pressure was elevated from 68 to 800 Pa. The limit of detection could be decreased by increasing the ion source pressure. Graphical Abstract ᅟ.

  17. Effects of Solvent and Ion Source Pressure on the Analysis of Anabolic Steroids by Low Pressure Photoionization Mass Spectrometry

    Science.gov (United States)

    Liu, Chengyuan; Zhu, Yanan; Yang, Jiuzhong; Zhao, Wan; Lu, Deen; Pan, Yang

    2017-04-01

    Solvent and ion source pressure were two important factors relating to the photon induced ion-molecule reactions in low pressure photoionization (LPPI). In this work, four anabolic steroids were analyzed by LPPI mass spectrometry. Both the ion species present and their relative abundances could be controlled by switching the solvent and adjusting the ion source pressure. Whereas M•+, MH+, [M - H2O]+, and solvent adducts were observed in positive LPPI, [M - H]- and various oxidation products were abundant in negative LPPI. Changing the solvent greatly affected formation of the ion species in both positive and negative ion modes. The ion intensities of the solvent adduct and oxygen adduct were selectively enhanced when the ion source pressure was elevated from 68 to 800 Pa. The limit of detection could be decreased by increasing the ion source pressure.

  18. Low-pressure pulsed focused ultrasound with microbubbles promotes an anticancer immunological response.

    Science.gov (United States)

    Liu, Hao-Li; Hsieh, Han-Yi; Lu, Li-An; Kang, Chiao-Wen; Wu, Ming-Fang; Lin, Chun-Yen

    2012-11-11

    High-intensity focused-ultrasound (HIFU) has been successfully employed for thermal ablation of tumors in clinical settings. Continuous- or pulsed-mode HIFU may also induce a host antitumor immune response, mainly through expansion of antigen-presenting cells in response to increased cellular debris and through increased macrophage activation/infiltration. Here we demonstrated that another form of focused ultrasound delivery, using low-pressure, pulsed-mode exposure in the presence of microbubbles (MBs), may also trigger an antitumor immunological response and inhibit tumor growth. A total of 280 tumor-bearing animals were subjected to sonographically-guided FUS. Implanted tumors were exposed to low-pressure FUS (0.6 to 1.4 MPa) with MBs to increase the permeability of tumor microvasculature. Tumor progression was suppressed by both 0.6 and 1.4-MPa MB-enhanced FUS exposures. We observed a transient increase in infiltration of non-T regulatory (non-Treg) tumor infiltrating lymphocytes (TILs) and continual infiltration of CD8+ cytotoxic T-lymphocytes (CTL). The ratio of CD8+/Treg increased significantly and tumor growth was inhibited. Our findings suggest that low-pressure FUS exposure with MBs may constitute a useful tool for triggering an anticancer immune response, for potential cancer immunotherapy.

  19. Thomson scattering on a low-pressure, inductively-coupled gas discharge lamp

    International Nuclear Information System (INIS)

    Sande, M.J. van de; Mullen, J.J.A.M. van der

    2002-01-01

    Excitation and light production processes in gas discharge lamps are the result of inelastic collisions between atoms and free electrons in the plasma. Therefore, knowledge of the electron density n e and temperature T e is essential for a proper understanding of such plasmas. In this paper, an experimental system for laser Thomson scattering on a low-pressure, inductively-coupled gas discharge lamp and measurements of n e and T e in this lamp are presented. The experimental system is suitable for low electron temperatures (down to below 0.2 eV) and employs a triple grating spectrograph for a high stray light rejection, or equivalently a low stray light redistribution (R eff approximately 7x10 -9 nm -1 at 0.5 nm from the laser wavelength). The electron density detection limit of the system is n e approximately 10 16 m -3 . The modifications to the lamp that were necessary for the measurements are described, and results are presented and compared to previous work and trends expected from the electron particle and energy balances. The electron density and temperature are about n e approximately 10 19 m -3 and T e approximately 1 eV in the most active part of the plasma; the exact values depend on the argon filling pressure, the mercury pressure and the position in the lamp. (author)

  20. Current limitation in low pressure mercury arcs

    International Nuclear Information System (INIS)

    Torven, S.; Babic, M.

    1976-06-01

    When the electric current in a low pressure arc with a long positive column is increased sufficiently, an electrostatic instability develops in the plasma which leads to formation of thin space charge layers across the column. The instability is investigated in a mercury plasma column kept axially homogeneous by a special technique. Values of some plasma parameters are measured at the instability threshold. It is found that the plasma is in a weakly ionized state in contrast to predictions by widely accepted current limitation theories. It is concluded that new types of theories are required to explain the observations. (Auth.)

  1. Useful effectiveness of plastic pipes for gas pipelines operating at low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Zayutsev, K I

    1976-06-01

    Because a significant portion of the feeder lines in the Soviet union operate at relatively low pressures up to 75 to 150 psi, it is economically feasible to replace the conventional pipeline material (steel) with plastic. Cost savings result from lower material costs and ease of laying plastic pipe. Because of stiffness and corrosion requirements, the steel pipe used for these low-pressure pipelines is much thicker than needed to withstand the pressure used. Data are tabulated on the comparative costs and manpower requirements for the construction of 1 km of steel, polyvinyl chloride, and polyethylene gas pipelines ranging in diameter from 3 to 14 in. Generally, the plastic pipelines required 15 to 30% less man-days and were 20 to 35% lower in cost to build. The plastic pipelines can operate at 150 to 175 psi pressure and at temperatures up to 100 to 140/sup 0/F. In research conducted at VNIIST (All-Union Research Institute for the Construction of Trunk Pipelines) on plastic pipelines, a 2.5-mile test section has been operating successfully for 2 years, and new techniques and equipment for joining plastic pipe up to 25-in. diameter are being developed.

  2. Low pressure drop filtration of airborne molecular organic contaminants using open-channel networks

    Science.gov (United States)

    Dallas, Andrew J.; Joriman, Jon; Ding, Lefei; Weineck, Gerald; Seguin, Kevin

    2007-03-01

    Airborne molecular contamination (AMC) continues to play a very decisive role in the performance of many microelectronic devices and manufacturing processes. Besides airborne acids and bases, airborne organic contaminants such as 1-methyl-2-pyrrolidinone (NMP), hexamethyldisiloxane (HMDSO), trimethylsilanol (TMS), perfluoroalkylamines and condensables are of primary concern in these applications. Currently, the state of the filtration industry is such that optimum filter life and removal efficiency for organics is offered by granular carbon filter beds. However, the attributes that make packed beds of activated carbon extremely efficient also impart issues related to elevated filter weight and pressure drop. Most of the lower pressure drop AMC filters currently offered are quite expensive and are simply pleated combinations of various adsorptive and reactive media. On the other hand, low pressure drop filters, such as those designed as open-channel networks (OCN's), offer good filter life and removal efficiency with the additional benefits of significant reductions in overall filter weight and pressure drop. Equally important for many applications, the OCN filters can reconstruct the airflow so as to enhance the operation of a tool or process. For tool mount assemblies and fan filter units (FFUs) this can result in reduced fan and blower speeds, which subsequently can provide reduced vibration and energy costs. Additionally, these low pressure drop designs can provide a cost effective way of effectively removing AMC in full fab (or HVAC) filtration applications without significantly affecting air-handling requirements. Herein, we will present a new generation of low pressure drop OCN filters designed for the removal of airborne organics in a wide range of applications.

  3. Extreme accident mitigation - analysis of a low pressure secondary containment building

    International Nuclear Information System (INIS)

    Vaughan, G.J.; Dunbar, I.H.

    1987-01-01

    Although whole core accidents are sufficiently unlikely as to be beyond the design basis, the Secondary Containment Building [SCB] is expected to have some effect in mitigating the consequences of such accidents. From a design point of view there are many advantages in having a low pressure SCB fitted with a filtered vent, so studies have been undertaken of the response of such a building to the large sodium fires that might follow a severe accident. The behaviour of the sodium oxide aerosols has been studied using the code AEROSIM. The efficiency of an aerosol scrubber has been investigated experimentally. A simple code, SECCONTAIN, has been developed to model the effects of sodium fires in buildings, and has been applied to a specific design of a low pressure SCB. (author)

  4. Nobel physics prize to Charpak for inventing particle detectors

    International Nuclear Information System (INIS)

    Schwarzschild, B.

    1993-01-01

    This article describes the work of Georges Charpak of France leading to his receipt of the 1992 Nobel Prize in Physics. The Nobel Prize was awarded to Charpak open-quotes for his invention and development of particle detectors, in particular the multiwire proportional chamber.close quotes Historical aspects of Charpak's life and research are given

  5. A comparison of low-pressure and supercharged operation of polymer electrolyte membrane fuel cell systems for aircraft applications

    Science.gov (United States)

    Werner, C.; Preiß, G.; Gores, F.; Griebenow, M.; Heitmann, S.

    2016-08-01

    Multifunctional fuel cell systems are competitive solutions aboard future generations of civil aircraft concerning energy consumption, environmental issues, and safety reasons. The present study compares low-pressure and supercharged operation of polymer electrolyte membrane fuel cells with respect to performance and efficiency criteria. This is motivated by the challenge of pressure-dependent fuel cell operation aboard aircraft with cabin pressure varying with operating altitude. Experimental investigations of low-pressure fuel cell operation use model-based design of experiments and are complemented by numerical investigations concerning supercharged fuel cell operation. It is demonstrated that a low-pressure operation is feasible with the fuel cell device under test, but that its range of stable operation changes between both operating modes. Including an external compressor, it can be shown that the power demand for supercharging the fuel cell is about the same as the loss in power output of the fuel cell due to low-pressure operation. Furthermore, the supercharged fuel cell operation appears to be more sensitive with respect to variations in the considered independent operating parameters load requirement, cathode stoichiometric ratio, and cooling temperature. The results indicate that a pressure-dependent self-humidification control might be able to exploit the potential of low-pressure fuel cell operation for aircraft applications to the best advantage.

  6. Effect of the potential well on low temperature pressure broadening in CO-He

    Science.gov (United States)

    Palma, A.; Green, S.

    1986-01-01

    Previously reported low-temperature pressure-broadening calculations (Green, 1985) for CO-He interacting via an SCF-CI potential are compared with new calculations in which the attractive part of the potential is either reduced by half or eliminated entirely. Results demonstrate that the attractive well is responsible for low-temperature enhancement of pressure-broadening cross sections and suggest that agreement with recent experimental values at 4 K (Messer and DeLucia, 1984) can be obtained by a modest reduction, probably within the expected uncertainty, in the attractive part of the SCF-CI potential.

  7. Residual heat removal pump and low pressure safety injection pump retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; McKenna, J.M.

    1992-01-01

    Residual Heat Removal (RHR) and low pressure safety injection (LPSI) pumps installed in pressurized water-to-reactor power plants are used to provide low-head safety injection in the event of loss of coolant in the reactor coolant system. Because these pumps are subjected to rather severe temperature and pressure transients, the majority of pumps installed in the RHR service are vertical pumps with a single stage impeller. Typically the pump impeller is mounted on an extended motor shaft (close-coupled configuration) and a mechanical seal is employed at the pump end of the shaft. Traditionally RHR and LPSI pumps have been a significant maintenance item for many utilities. Periodic mechanical seal of motor bearing replacement often is considered routine maintenance. The closed-coupled pump design requires disassembly of the casing cover from the lower pump casing while performing these routine maintenance tasks. This paper introduces a design modification developed to convert the close-coupled RHR and LPSI pumps to a coupled configuration

  8. Thomson scattering in a low-pressure argon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2000-01-01

    The electron density and the electron temperature in a low-pressure argon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 5

  9. Thomson scattering in a low-pressure neon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2001-01-01

    The electron density and the electron temperature in a low-pressure neon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 10

  10. An array of low-background 3He proportional counters for theSudbury Neutrino Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Amsbaugh, J.F.; Anaya, J.M.; Banar, J.; Bowles, T.J.; Browne,M.C.; Bullard, T.V.; Burritt, T.H.; Cox-Mobrand, G.A.; Dai, X.; H.Deng,X.; Di Marco, M.; Doe, P.J.; Dragowsky, M.R.; Duba, C.A.; Duncan, F.A.; Earle, E.D.; Elliott, S.R.; Esch, E.-I.; Fergani, H.; Formaggio, J.A.; Fowler, M.M.; Franklin, J.E.; Geissbuehler, P.; Germani, J.V.; Goldschmidt, A.; Guillian, E.; Hallin, A.L.; Harper, G.; Harvey, P.J.; Hazama, R.; Heeger, K.M.; Heise, J.; Hime, A.; Howe, M.A.; Huang, M.; Kormos, L.L.; Kraus, C.; Krauss, C.B.; Law, J.; Lawson, I.T.; Lesko,K.T.; Loach, J.C.; Majerus, S.; Manor, J.; McGee, S.; Miknaitis, K.K.S.; Miller, G.G.; Morissette, B.; Myers, A.; Oblath, N.S.; O' Kee, H.M.; Ollerhead, R.W.; Peeters, S.J.M.; Poon, A.W.P.; Prior, G.; Reitzner,S.D.; Rielage, K.; Robertson, R.G.H.; Skensved, P.; Smith, A.R.; Smith,M.W.E.; Steiger, T.D.; Stonehill,L.C.; Thornewell, P.M.; Tolich, N.; VanDevender, B.A.; VanWechel, T.D.; Wall, B.L.; Tseung, H.W.C.; Wendland,J.; West, N.; Wilhelmy, J.B.; Wilkerson, J.F.; Wouters, J.M.

    2007-02-01

    An array of Neutral-Current Detectors (NCDs) has been builtin order to make a unique measurement of the total active ux of solarneutrinos in the Sudbury Neutrino Observatory (SNO). Data in the thirdphase of the SNO experiment were collected between November 2004 andNovember 2006, after the NCD array was added to improve theneutral-current sensitivity of the SNO detector. This array consisted of36 strings of proportional counters lled with a mixture of 3He and CF4gas capable of detecting the neutrons liberated by the neutrino-deuteronneutral current reaction in the D2O, and four strings lled with a mixtureof 4He and CF4 gas for background measurements. The proportional counterdiameter is 5 cm. The total deployed array length was 398 m. The SNO NCDarray is the lowest-radioactivity large array of proportional countersever produced. This article describes the design, construction,deployment, and characterization of the NCD array, discusses theelectronics and data acquisition system, and considers event signaturesand backgrounds.

  11. The Proportion of Anemia Associated with Iron Deficiency in Low, Medium, and High Human Development Index Countries: A Systematic Analysis of National Surveys

    Directory of Open Access Journals (Sweden)

    Nicolai Petry

    2016-11-01

    Full Text Available Iron deficiency is commonly assumed to cause half of all cases of anemias, with hereditary blood disorders and infections such as hookworm and malaria being the other major causes. In countries ranked as low, medium, and high by the Human Development Index, we conducted a systematic review of nationally representative surveys that reported the prevalence of iron deficiency, iron deficiency anemia, and anemia among pre-school children and non-pregnant women of reproductive age. Using random effects meta-analyses techniques, data from 23 countries for pre-school children and non-pregnant women of reproductive age was pooled, and the proportion of anemia attributable to iron deficiency was estimated by region, inflammation exposure, anemia prevalence, and urban/rural setting. For pre-school children and non-pregnant women of reproductive age, the proportion of anemia associated with iron deficiency was 25.0% (95% CI: 18.0, 32.0 and 37.0% (95% CI: 28.0, 46.0, respectively. The proportion of anemia associated with iron deficiency was lower in countries where anemia prevalence was >40%, especially in rural populations (14% for pre-school children; 16% for non-pregnant women of reproductive age, and in countries with very high inflammation exposure (20% for pre-school children; 25% for non-pregnant women of reproductive age. Despite large heterogeneity, our analyses suggest that the proportion of anemia associated with iron deficiency is lower than the previously assumed 50% in countries with low, medium, or high Human Development Index ranking. Anemia-reduction strategies and programs should be based on an analysis of country-specific data, as iron deficiency may not always be the key determinant of anemia.

  12. The Proportion of Anemia Associated with Iron Deficiency in Low, Medium, and High Human Development Index Countries: A Systematic Analysis of National Surveys

    Science.gov (United States)

    Petry, Nicolai; Olofin, Ibironke; Hurrell, Richard F.; Boy, Erick; Wirth, James P.; Moursi, Mourad; Donahue Angel, Moira; Rohner, Fabian

    2016-01-01

    Iron deficiency is commonly assumed to cause half of all cases of anemias, with hereditary blood disorders and infections such as hookworm and malaria being the other major causes. In countries ranked as low, medium, and high by the Human Development Index, we conducted a systematic review of nationally representative surveys that reported the prevalence of iron deficiency, iron deficiency anemia, and anemia among pre-school children and non-pregnant women of reproductive age. Using random effects meta-analyses techniques, data from 23 countries for pre-school children and non-pregnant women of reproductive age was pooled, and the proportion of anemia attributable to iron deficiency was estimated by region, inflammation exposure, anemia prevalence, and urban/rural setting. For pre-school children and non-pregnant women of reproductive age, the proportion of anemia associated with iron deficiency was 25.0% (95% CI: 18.0, 32.0) and 37.0% (95% CI: 28.0, 46.0), respectively. The proportion of anemia associated with iron deficiency was lower in countries where anemia prevalence was >40%, especially in rural populations (14% for pre-school children; 16% for non-pregnant women of reproductive age), and in countries with very high inflammation exposure (20% for pre-school children; 25% for non-pregnant women of reproductive age). Despite large heterogeneity, our analyses suggest that the proportion of anemia associated with iron deficiency is lower than the previously assumed 50% in countries with low, medium, or high Human Development Index ranking. Anemia-reduction strategies and programs should be based on an analysis of country-specific data, as iron deficiency may not always be the key determinant of anemia. PMID:27827838

  13. The Proportion of Anemia Associated with Iron Deficiency in Low, Medium, and High Human Development Index Countries: A Systematic Analysis of National Surveys.

    Science.gov (United States)

    Petry, Nicolai; Olofin, Ibironke; Hurrell, Richard F; Boy, Erick; Wirth, James P; Moursi, Mourad; Donahue Angel, Moira; Rohner, Fabian

    2016-11-02

    Iron deficiency is commonly assumed to cause half of all cases of anemias, with hereditary blood disorders and infections such as hookworm and malaria being the other major causes. In countries ranked as low, medium, and high by the Human Development Index, we conducted a systematic review of nationally representative surveys that reported the prevalence of iron deficiency, iron deficiency anemia, and anemia among pre-school children and non-pregnant women of reproductive age. Using random effects meta-analyses techniques, data from 23 countries for pre-school children and non-pregnant women of reproductive age was pooled, and the proportion of anemia attributable to iron deficiency was estimated by region, inflammation exposure, anemia prevalence, and urban/rural setting. For pre-school children and non-pregnant women of reproductive age, the proportion of anemia associated with iron deficiency was 25.0% (95% CI: 18.0, 32.0) and 37.0% (95% CI: 28.0, 46.0), respectively. The proportion of anemia associated with iron deficiency was lower in countries where anemia prevalence was >40%, especially in rural populations (14% for pre-school children; 16% for non-pregnant women of reproductive age), and in countries with very high inflammation exposure (20% for pre-school children; 25% for non-pregnant women of reproductive age). Despite large heterogeneity, our analyses suggest that the proportion of anemia associated with iron deficiency is lower than the previously assumed 50% in countries with low, medium, or high Human Development Index ranking. Anemia-reduction strategies and programs should be based on an analysis of country-specific data, as iron deficiency may not always be the key determinant of anemia.

  14. Aschroft Pressure Switch - Monitor for Low SCHe Supply Bottle Pressure

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    These pressure switches are located in the SCHe helium supply lines at the pressure bottles and upstream of the PRV. The switches monitor the SCHe supply bottle pressure and are set to alarm at 2200 psig. There is one switch for each SCHe supply (4). Electronic output signal is NON-SAFETY (GS)

  15. Proportional lumbar spine inter-vertebral motion patterns: a comparison of patients with chronic, non-specific low back pain and healthy controls

    OpenAIRE

    Mellor, Fiona E.; Thomas, Peter; Thompson, Paul W.; Breen, Alan C.

    2014-01-01

    Introduction: Identifying biomechanical subgroups in chronic, non-specific low back pain (CNSLBP) populations from inter-vertebral displacements has proven elusive. Quantitative fluoroscopy (QF) has excellent repeatability and provides continuous standardised inter-vertebral kinematic data from fluoroscopic sequences allowing assessment of mid-range motion. The aim of this study was to determine whether proportional continuous IV rotational patterns were different in patients and controls. A ...

  16. H_{2} adsorption on multiwalled carbon nanotubes at low temperatures and low pressures

    Directory of Open Access Journals (Sweden)

    F. Xu

    2008-11-01

    Full Text Available We present an experimental study on H_{2} adsorption on multiwalled carbon nanotubes (MWCNTs at low temperatures (12–30 K and low pressures (2×10^{-5}  Torr using the temperature programmed desorption technique. Our results show that the molecular hydrogen uptake increases nearly exponentially from 6×10^{-9}  wt. % at 24.5 K to 2×10^{-7}  wt. % at 12.5 K and that the desorption kinetics is of the first order. Comparative measurements indicate that MWCNTs have an adsorption capacity about two orders higher than that of activated carbon (charcoal making them a possible candidate as hydrogen cryosorber for eventual applications in accelerators and synchrotrons.

  17. Enhancement of Giant Magneto-Impedance in Series Co-Rich Microwires for Low-Field Sensing Applications

    Science.gov (United States)

    Jiang, S. D.; Eggers, T.; Thiabgoh, O.; Xing, D. W.; Fang, W. B.; Sun, J. F.; Srikanth, H.; Phan, M. H.

    2018-02-01

    Two soft ferromagnetic Co68.25Fe4.25Si12.25B15.25 microwires with the same diameter of 50 ± 1 μm but different fabrication processes were placed in series and in parallel circuit configurations to investigate their giant magneto-impedance (GMI) responses in a frequency range of 1-100 MHz for low-field sensing applications. We show that, while the low-field GMI response is significantly reduced in the parallel configuration, it is greatly enhanced in the series connection. These results suggest that a highly sensitive GMI sensor can be designed by arranging multi-wires in a saw-shaped fashion to optimize the sensing area, and soldered together in series connection to maintain the excellent magnetic field sensitivity.

  18. Fatigue damage assessment under multi-axial non-proportional cyclic loading

    International Nuclear Information System (INIS)

    Mohta, Keshav; Gupta, Suneel K.; Jadhav, P.A.; Bhasin, V.; Vijayan, P.K.

    2016-01-01

    Detailed fatigue analysis is carried out for class I Nuclear Power Plant (NPP) components to rule out the fatigue failure during their design lifetime. ASME Boiler and Pressure Vessel code Section III NB, has provided two schemes for fatigue assessment, one for fixed principal directions (proportional) loading and the other for varying principal directions (non-proportional) loading conditions. Recent literature on multi-axial fatigue tests has revealed lower fatigue lives under nonproportional loading conditions. In an attempt to understand the loading parameter lowering the fatigue life, a finite element based study has been carried out. Here, fatigue damage in a tube has been correlated with the applied axial to shear strain ratio and phase difference between them. The FE analysis has used Chaboche nonlinear kinematic hardening rule to model material's realistic cyclic plastic deformation behavior. The ASME alternating stress intensity (based on linear elastic FEA) and the plastic strain energy dissipation (based on elastic-plastic FEA) have been considered to assess the per cycle fatigue damage. The study has revealed that ASME criteria predicts lower alternating stress intensity (fatigue damage parameter S alt ) for some cases of non-proportional loading than that predicted for corresponding proportional loading case. However, the actual fatigue damage is higher in non-proportional loading than that in corresponding proportional loading case. Further the fatigue damage of an NPP component under realistic multi-axial cyclic loading conditions has been assessed using some popular critical plane based models vis-à-vis ASME Sec. III criteria. (author)

  19. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  20. Structure and oxygen incorporation in low pressure sputtered YBCO films

    International Nuclear Information System (INIS)

    Chaudhary, S.; Pandya, D. K.; Kashyap, S. C.

    2002-01-01

    Thin films of YBa 2 Cu 3 O 7- δ (YBCO) have been successfully grown by reactive RF-magnetron sputtering technique at low pressure. The oxygen partial pressure of 0.95 mTorr, a total pressure (argon and oxygen) of 1.9 mTorr, and a substrate temperature of 775 grad C resulted in good quality films with T C (R=0) = 85.3 K and J Cmag (4.2 K) ≅ 2x10 7 A/cm 2 . The incorporation of oxygen in the as-grown films has been controlled by using different ambient - oxygen, air or argon during in-situ cooling. The superconducting behaviour of the films was studied using resistance-temperature and low field ac-susceptibility measurements and correlated with their structure. All the films exhibited metallic conduction in the normal state. The oxygen- and air- cooled films were superconducting, possessing the usual orthorhombic structure. The argon-cooled films were non-superconducting possessing the tetragonal structure, thus implying that the structure of the film during deposition is tetragonal which transforms to either of the oxygen rich orthorhombic-I or -II phases depending upon the oxygen/air ambient. The 'δ' values of 0.14, 0.32 and 0.70 and higher 'c'-parameters of 1.1785, 1.180 and 1.183 nm have been obtained for oxygen, air and argon cooled films respectively. (Authors)

  1. Some aspects of the use of proton recoil proportional counters for fast neutron personnel dosimeters

    International Nuclear Information System (INIS)

    Yule, T.J.; Bennett, E.F.

    1984-01-01

    Gas-filled proton recoil proportional counters have been used extensively for the measurement of neutron spectra in degraded fission-spectrum environments. Some considerations relating to the use of these counters for personnel dosimetry are here described. High sensitivity and good accuracy in the determination of dose-equivalent can be obtained if relatively high pressure hydrogen-filled proportional counters are used as the active element in a dosimeter system

  2. Atomic and molecular hydrogen gas temperatures in a low-pressure helicon plasma

    Science.gov (United States)

    Samuell, Cameron M.; Corr, Cormac S.

    2015-08-01

    Neutral gas temperatures in hydrogen plasmas are important for experimental and modelling efforts in fusion technology, plasma processing, and surface modification applications. To provide values relevant to these application areas, neutral gas temperatures were measured in a low pressure (radiofrequency helicon discharge using spectroscopic techniques. The atomic and molecular species were not found to be in thermal equilibrium with the atomic temperature being mostly larger then the molecular temperature. In low power operation (measurements near a graphite target demonstrated localised cooling near the sample surface. The temporal evolution of the molecular gas temperature during a high power 1.1 ms plasma pulse was also investigated and found to vary considerably as a function of pressure.

  3. Joint Association of Low Vitamin D and Vitamin K Status With Blood Pressure and Hypertension.

    Science.gov (United States)

    van Ballegooijen, Adriana J; Cepelis, Aivaras; Visser, Marjolein; Brouwer, Ingeborg A; van Schoor, Natasja M; Beulens, Joline W

    2017-06-01

    Low vitamin D and K status are both associated with an increased cardiovascular risk. New evidence from experimental studies on bone health suggest an interaction between vitamin D and K; however, a joint association with vascular health outcomes is largely unknown. To prospectively investigate whether the combination of low vitamin D and K status is associated with higher systolic and diastolic blood pressure in 402 participants and with incident hypertension in 231 participants free of hypertension at baseline. We used data from a subsample of the Longitudinal Aging Study Amsterdam, a population-based cohort of Dutch participants aged 55 to 65 years. Vitamin D and K status were assessed by 25-hydroxyvitamin D and dp-ucMGP (dephosphorylated uncarboxylated matrix gla protein) concentrations (high dp-ucMGP is indicative for low vitamin K status) in stored samples from 2002 to 2003. Vitamin D and K status were categorized into 25-hydroxyvitamin D hypertension. The combination of low vitamin D and K status was associated with increased systolic 4.8 mm Hg (95% confidence interval, 0.1-9.5) and diastolic 3.1 mm Hg (95% confidence interval, 0.5-5.7) blood pressure compared with high vitamin D and K status ( P for interaction =0.013 for systolic blood pressure and 0.068 for diastolic blood pressure). A similar trend was seen for incident hypertension: hazard ratio=1.62 (95% confidence interval, 0.96-2.73) for the low vitamin D and K group. The combination of low vitamin D and K status was associated with increased blood pressure and a trend for greater hypertension risk. © 2017 American Heart Association, Inc.

  4. Influence of depth of neuromuscular blockade on surgical conditions during low-pressure pneumoperitoneum laparoscopic cholecystectomy: A randomized blinded study.

    Science.gov (United States)

    Barrio, Javier; Errando, Carlos L; García-Ramón, Jaime; Sellés, Rafael; San Miguel, Guillermo; Gallego, Juan

    2017-11-01

    To evaluate the influence of neuromuscular blockade (NMB) on surgical conditions during low-pressure pneumoperitoneum (8mmHg) laparoscopic cholecystectomy (LC), while comparing moderate and deep NMB. Secondary objective was to evaluate if surgical conditions during low-pressure pneumoperitoneum LC performed with deep NMB could be comparable to those provided during standard-pressure pneumoperitoneum (12mmHg) LC. Prospective, randomized, blinded clinical trial. Operating room. Ninety ASA 1-2 patients scheduled for elective LC. Patients were allocated into 3 groups: Group 1: low-pressure pneumoperitoneum with moderate-NMB (1-3 TOF), Group 2: low-pressure pneumoperitoneum with deep-NMB (1-5 PTC) and Group 3: standard pneumoperitoneum (12mmHg). Rocuronium was used to induce NMB and acceleromiography was used for NMB monitoring (TOF-Watch-SX). Three experienced surgeons evaluated surgical conditions using a four-step scale at three time-points: surgical field exposure, dissection of the gallbladder and extraction/closure. Low-pressure pneumoperitoneum (Group 1 vs. 2): good conditions: 96.7 vs. 96.7%, 90 vs. 80% and 89.6 vs. 92.3%, respectively for the time-points, p>0.05. No differences in optimal surgical conditions were observed between the groups. Surgery completion at 8mmHg pneumoperitoneum: 96.7 vs. 86.7%, p=0.353. Standard-pressure pneumoperitoneum vs. low-pressure pneumoperitoneum with deep NMB (Group 3 vs. 2): good conditions: 100% in Group 3 for the three time-points (p=0.024 vs. Group 2 at dissection of the gallbladder). Significantly greater percentage of optimal conditions during standard-pressure pneumoperitoneum LC at the three time points of evaluation. The depth of NMB was found not to be decisive neither in the improvement of surgical conditions nor in the completion of low-pressure pneumoperitoneum LC performed by experienced surgeons. Surgical conditions were considered better with a standard-pressure pneumoperitoneum, regardless of the depth of NMB

  5. Pulse-shape discrimination in IAEA tritium proportional counters

    International Nuclear Information System (INIS)

    Florkowski, T.

    1981-01-01

    Two systems of pulse-shape discrimination (PSD) for the reduction of background in low-level proportional counters were tested. A tentative conclusion is drawn that both PSD systems, although they decrease slightly the meson background, do not bring improvement in the analytical accuracy

  6. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  7. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  8. Neutron detector array at IUAC: Design features and instrumentation ...

    Indian Academy of Sciences (India)

    2014-11-02

    Nov 2, 2014 ... multi-wire proportional counters mounted inside a 1 m diameter SS target chamber. ... a powerful tool to study the dynamics of the fissioning system and a ... neutron multiplicity for three isotopes across a major closed shell, .... voltage by connecting to the control pin of the chip via a 0–5V programmable volt-.

  9. A digital x-ray imaging MWPC detector system for precision absorptiometry

    International Nuclear Information System (INIS)

    Batemen, J.E.; Connolly, J.F.; Glasgow, W.

    1977-11-01

    An X-ray absorptiometric imaging system (based on a xenon-filled multiwire proportional counter) has been developed with high counting rate capability, good spatial resolution and linear mass response, aimed at permitting bone mass measurements to be made in the peripheral skeleton with precision approaching 1%. The system is described and preliminary results on test phantoms are presented. (author)

  10. Monitoring of the ageing of the DELPHI Barrel RICH MWPCs

    International Nuclear Information System (INIS)

    Apeldoorn, G.; Buys, A.; Dracos, M.; Toet, D.Z.

    1996-01-01

    We describe a method to monitor ageing effects in the multiwire proportional chambers (MWPCs) of the barrel ring imaging Cherenkov (BRICH) detector of DELPHI. It is based on a measurement of plateau-curve characteristics and the shift of these as a function of the total collected charge. Results indicate that, as yet, no ageing effects are present. (orig.)

  11. LAMBDA p total cross-section measurement

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    A view of the apparatus used for the LAMBDA p total cross-section measurement at the time of its installation. The hyperons decaying into a proton and a pion in the conical tank in front were detected in the magnet spectrometer in the upper half of the picture. A novel detection technique using exclusively multiwire proportional chambers was employed.

  12. Heat transfers in a low-pressure arc-jet

    Energy Technology Data Exchange (ETDEWEB)

    Dudeck, M [Centre National de la Recherche Scientifique (CNRS), 92 - Meudon-Bellevue (France); Kaminska, A [Politechnika Poznanska, Poznan (Poland)

    1995-03-01

    In the framework of low-pressure arc-jet applications to thermodynamical condition simulation for reentry vehicles at hypersonic speed, an analytical study has been carried out concerning the thermodynamical conditions of a plasma in an arc-source for plasmatron usual operating conditions. After a review of gas physical properties, the gas flow in the plasmatron with a divergent nozzle is modelled; temperature profiles in the arc and in the divergent and the wall heat flux are then computed. Results are given. 8 refs., 6 figs.

  13. Self-contained high-pressure chambers for study on the Moessbauer effect at low temperatures

    International Nuclear Information System (INIS)

    Stepanov, G.N.

    1980-01-01

    Designs of two high-pressure chambers intended for studying the Moessbauer effect at low temperatures are described. The high-pressure chamber of the Bridgman anvil type is made of non magnetic materials and intended for operation at helium temperatures. The chamber employs a superconducting pressure gage. A sample and superconducting pressure gage are surrounded with a liquid medium of a high pressure at a room temperature. Measurements of the pressure were taken during heating the chamber in the vapours of liquid helium according to the known dependence of the lead superconducting transition temperature on pressure. The other high-pressure chamber of the piston-to-cylinder type can be used to study the Moessbauer effect at temperatures ranging from 4 to 300 K. Pressure in the chamber is measured by means of the superconducting pressure gage. The maximum pressure obtained in the chamber constitutes 25 kbar

  14. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube (SWCNT)/alginate hydrogel spheres is reported. Conductive and piezoresistive spheres are embedded between conductive electrodes (indium tin oxide-coated polyethylene terephthalate films) and subjected to environmental pressure. The detection mechanism is based on the piezoresistivity of the SWCNT/alginate conductive spheres and on the sphere-electrode contact. Step-by-step, we optimized the design parameters to maximize the sensitivity of the sensor. The optimized hydrogel sensor exhibited a satisfactory sensitivity (0.176 ΔR/R0/kPa-1) and a low detectable limit (10 Pa). Moreover, a brief response time (a few milliseconds) and successful repeatability were also demonstrated. Finally, the efficiency of this strategy was verified through a series of practical tests such as monitoring human wrist pulse, detecting throat muscle motion or identifying the location and the distribution of an external pressure using an array sensor (4 × 4). © 2015 The Royal Society of Chemistry.

  15. Position-sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hendrix, J.

    1982-01-01

    An overview is given of the different types of position-sensitive X-ray detectors used in kinetic studies of biological molecule state changes using X-ray diffraction with synchrotron radiation as a probe. The detector requirements and principles of operation of proportional counters are outlined. Multiwire proportional chamber systems and their readout techniques are described. Other detectors discussed include a drift chamber type detector, microchannel plates, charge-couple devices and, for high count rates, an integrating TV-detector. (U.K.)

  16. An experimental and kinetic modeling study of premixed nitroethane flames at low pressure

    DEFF Research Database (Denmark)

    Zhang, Kuiwen; Zhang, Lidong; Xie, Mingfeng

    2013-01-01

    An experimental and kinetic modeling study is reported on three premixed nitroethane/oxygen/argon flames at low pressure (4.655kPa) with the equivalence ratios (Φ) of 1.0, 1.5 and 2.0. Over 30 flame species were identified with tunable synchrotron vacuum ultraviolet photoionization mass spectrome......An experimental and kinetic modeling study is reported on three premixed nitroethane/oxygen/argon flames at low pressure (4.655kPa) with the equivalence ratios (Φ) of 1.0, 1.5 and 2.0. Over 30 flame species were identified with tunable synchrotron vacuum ultraviolet photoionization mass...

  17. Evaluation of heat transfer coefficient of tungsten filaments at low pressures and high temperatures

    International Nuclear Information System (INIS)

    Chondrakis, N.G.; Topalis, F.V.

    2011-01-01

    The paper presents an experimental method for the evaluation of the heat transfer coefficient of tungsten filaments at low pressures and high temperatures. For this purpose an electrode of a T5 fluorescent lamp was tested under low pressures with simultaneous heating in order to simulate the starting conditions in the lamp. It was placed in a sealed vessel in which the pressure was varied from 1 kM (kilo micron) to 760 kM. The voltage applied to the electrode was in the order of the filament's voltage of the lamp at the normal operation with the ballast during the preheating process. The operating frequency ranged from DC to 50 kHz. The experiment targeted on estimating the temperature of the electrode at the end of the first and the ninth second after initiating the heating process. Next, the heat transfer coefficient was calculated at the specific experimental conditions. A mathematical model based on the results was developed that estimates the heat transfer coefficient. The experiments under different pressures confirm that the filament's temperature strongly depends on the pressure.

  18. Effects of large pressure amplitude low frequency noise in the parotid gland perivasculo-ductal connective tissue.

    Science.gov (United States)

    Oliveira, Pedro; Brito, José; Mendes, João; da Fonseca, Jorge; Águas, Artur; Martins dos Santos, José

    2013-01-01

    In tissues and organs exposed to large pressure amplitude low frequency noise fibrosis occurs in the absence of inflammatory signs, which is thought to be a protective response. In the parotid gland the perivasculo-ductal connective tissue surrounds arteries, veins and the ductal tree. Perivasculo-ductal connective tissue is believed to function as a mechanical stabilizer of the glandular tissue. In order to quantify the proliferation of perivasculo-ductal connective tissue in large pressure amplitude low frequency noise-exposed rats we used sixty Wistar rats which were equally divided into 6 groups. One group kept in silence, and the remaining five exposed to continuous large pressure amplitude low frequency noise: g1-168h (1 week); g2-504h (3 weeks); g3-840h (5 weeks); g4-1512h (9 weeks); and g5-2184h (13 weeks). After exposure, parotid glands were removed and the perivasculo-ductal connective tissue area was measured in all groups. We applied ANOVA statistical analysis, using SPSS 13.0. The global trend is an increase in the average perivasculo-ductal connective tissue areas, that develops linearly and significantly with large pressure amplitude low frequency noise exposure time (p connective tissue. Hence, these results show that in response to large pressure amplitude low frequency noise exposure, rat parotid glands increase their perivasculo-ductal connective tissue.

  19. A Prototype Ice-Melting Probe for Collecting Biological Samples from Cryogenic Ice at Low Pressure

    Science.gov (United States)

    Davis, Ashley

    2017-08-01

    In the Solar System, the surface of an icy moon is composed of irregular ice formations at cryogenic temperatures (pumps. The device contains a heated conical probe with a central orifice, which is forced into surface ice and directs the meltwater upward into a reservoir. The force on the probe is proportional to the height of meltwater (pressure) obtained in the system and allows regulation of the melt rate and temperature of the sample. The device can collect 5-50 mL of meltwater from the surface of an ice block at 233-208 K with an environmental pressure of less than 10-2 atm while maintaining a sample temperature between 273 and 293 K. These conditions maintain most biological samples in a pristine state and maintain the integrity of most organisms' structure and function.

  20. Characteristic densities of low- and high-pressure liquid SnI4

    International Nuclear Information System (INIS)

    Fuchizaki, Kazuhiro; Hamaya, Nozomu; Katayama, Yoshinori

    2013-01-01

    An in situ synchrotron x-ray absorption measurement was carried out to estimate the density of liquid SnI 4 . The characteristic densities of the low- and high-pressure liquids were found to be 4.6-4.7 and 4.9-5.0 g/cm 3 , respectively, and their region is separated at around 1.7 GPa. The difference in density, although a slight amount of 0.3-0.4 g/cm 3 , strongly suggests the existence of a weak but discontinuous phase transition at that pressure between the two liquid regions. (author)

  1. A low-background piston-cylinder-type hybrid high pressure cell for muon-spin rotation/relaxation experiments

    Science.gov (United States)

    Shermadini, Z.; Khasanov, R.; Elender, M.; Simutis, G.; Guguchia, Z.; Kamenev, K. V.; Amato, A.

    2017-10-01

    A low background double-wall piston-cylinder-type pressure cell is developed at the Paul Scherrer Institute. The cell is made from BERYLCO-25 (beryllium copper) and MP35N nonmagnetic alloys with the design and dimensions which are specifically adapted to muon-spin rotation/relaxation (μSR) measurements. The mechanical design and performance of the pressure cell are evaluated using finite-element analysis (FEA). By including the measured stress-strain characteristics of the materials into the finite-element model, the cell dimensions are optimized with the aim to reach the highest possible pressure while maintaining the sample space large (6 mm in diameter and 12 mm high). The presented unconventional design of the double-wall piston-cylinder pressure cell with a harder outer MP35N sleeve and a softer inner CuBe cylinder enables pressures of up to 2.6 GPa to be reached at ambient temperature, corresponding to 2.2 GPa at low temperatures without any irreversible damage to the pressure cell. The nature of the muon stopping distribution, mainly in the sample and in the CuBe cylinder, results in a low-background μSR signal.

  2. Simulation of proportional control of hydraulic actuator using digital hydraulic valves

    Science.gov (United States)

    Raghuraman, D. R. S.; Senthil Kumar, S.; Kalaiarasan, G.

    2017-11-01

    Fluid power systems using oil hydraulics in earth moving and construction equipment have been using proportional and servo control valves for a long time to achieve precise and accurate position control backed by system performance. Such valves are having feedback control in them and exhibit good response, sensitivity and fine control of the actuators. Servo valves and proportional valves are possessing less hysteresis when compared to on-off type valves, but when the servo valve spools get stuck in one position, a high frequency called as jitter is employed to bring the spool back, whereas in on-off type valves it requires lesser technology to retract the spool. Hence on-off type valves are used in a technology known as digital valve technology, which caters to precise control on slow moving loads with fast switching times and with good flow and pressure control mimicking the performance of an equivalent “proportional valve” or “servo valve”.

  3. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  4. Evaluation of B10Plus+* proportional detectors for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Beddingfield, David H.; Yoon, Seokryung [International Atomic Energy Agency, Vienna International Centre, PO Box 100, 1400 Vienna, (Austria)

    2015-07-01

    GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the B10Plus+* proportional counter. The detector design is intended to serve as a cost-effective alternative to traditional {sup 3}He proportional counters in a variety of applications. The detector is a hybrid design 10B-lined tube optimized with the addition of a small quantity of 3He gas to improve the detector performance and efficiency. As a demonstration of the B10Plus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B-10Plus+* proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity. (authors)

  5. Precise electrical transport measurements by using Bridgman type pressure cell at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Oishi, Takayuki [Division of Civil and Enviromental Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Ohashi, Masashi [Faculty of Environmental Design, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan)

    2010-03-01

    We report a technique for the precise measurement of the electrical resisivity under high pressure at low temperature by using Bridgman anvils made of tungsten carbide. Quasi-hydrostatic pressure is generated up to {approx}15 GPa in the relatively large working space which allows the use of large specimens and simple experimental procedures rather than using a standard diamond anvil cell. The application is demonstrated by the measurements of the electrical resistivity of lead in order to describe the effect of pressure on the superconducting transition.

  6. Precise electrical transport measurements by using Bridgman type pressure cell at low temperature

    International Nuclear Information System (INIS)

    Oishi, Takayuki; Ohashi, Masashi

    2010-01-01

    We report a technique for the precise measurement of the electrical resisivity under high pressure at low temperature by using Bridgman anvils made of tungsten carbide. Quasi-hydrostatic pressure is generated up to ∼15 GPa in the relatively large working space which allows the use of large specimens and simple experimental procedures rather than using a standard diamond anvil cell. The application is demonstrated by the measurements of the electrical resistivity of lead in order to describe the effect of pressure on the superconducting transition.

  7. Disintegration of liquid metals by low pressure water blasting

    International Nuclear Information System (INIS)

    Heshmatpour, B.; Copeland, G.L.

    1981-01-01

    The feasibility of disintegrating metals by a low cost system and subsequently incorporating them into grout mixtures has been demonstrated. A low pressure water blasting technique consisting of multiple nozzles and a converging-line jet stream was developed to disintegrate liquid metals and produce coarse metal powder and shot. Molten iron resulted in spherical shot, while copper, aluminum, and tin produced irregular shaped particles. The particle size was between 0.05 and 3 mm (0.002 and 0.1 in.), and about half the particles were smaller than 1 mm (0.04 in.) in all cases. The water consumption was rather low, while the production rate was relatively high. The method proved to be simple and reliable. The coarse metal powders were suspendable in grout fluids, indicating that they are probably disposable by the shale hydrofracture technique

  8. Overview of research trends and problems on Cr-Mo low alloy steels for pressure vessel

    International Nuclear Information System (INIS)

    Chi, Byung Ha; Kim, Jeong Tae

    2000-01-01

    Cr-Mo low alloy steels have been used for a long time for pressure vessel due to its excellent corrosion resistance, high temperature strength and toughness. The paper reviewed the latest trends on material development and some problems on Cr-Mo low alloy steel for pressure vessel, such as elevated temperature strength, hardenability, synergetic effect between temper and hydrogen embrittlement, hydrogen attack and hydrogen induced disbonding of overlay weld-cladding

  9. Low pressure storage of natural gas on activated carbon

    Science.gov (United States)

    Wegrzyn, J.; Wiesmann, H.; Lee, T.

    The introduction of natural gas to the transportation energy sector offers the possibility of displacing imported oil with an indigenous fuel. The barrier to the acceptance of natural gas vehicles (NGV) is the limited driving range due to the technical difficulties of on-board storage of a gaseous fuel. In spite of this barrier, compressed natural gas (CNG) vehicles are today being successfully introduced into the market place. The purpose of this work is to demonstrate an adsorbent natural gas (ANG) storage system as a viable alternative to CNG storage. It can be argued that low pressure ANG has reached near parity with CNG, since the storage capacity of CNG (2400 psi) is rated at 190 V/V, while low pressure ANG (500 psi) has reached storage capacities of 180 V/V in the laboratory. A program, which extends laboratory results to a full-scale vehicle test, is necessary before ANG technology will receive widespread acceptance. The objective of this program is to field test a 150 V/V ANG vehicle in FY 1994. As a start towards this goal, carbon adsorbents have been screened by Brookhaven for their potential use in a natural gas storage system. This paper reports on one such carbon, trade name Maxsorb, manufactured by Kansai Coke under an Amoco license.

  10. Low-pressure c-BN deposition - is a CVD process possible?

    International Nuclear Information System (INIS)

    Haubner, R.; Tang, X.

    2001-01-01

    Since the low-pressure diamond deposition was discovered in 1982 there is a high interest to find a similar process for the c-BN synthesis. A review about the c-BN deposition process as well as its characterization is given. Experiments with a simple chemical vapor deposition(CVD) reactor using tris(dimethylamino)borane as precursor were carried out. In a cold-wall reactor substrates were heated up by high-frequency. Argon was used as protecting and carrying the precursor, it was saturated with tris(dimethylamino)borane (precursor) according to its vapor pressure and transports the pressure to the hot substrate, where deposition occurs. WC-Co hardmetal plates containing 6 wt. % Co, Mo and Si were used as substrates. Various BN layers were deposited and characterized. X-ray diffraction, IR-spectroscopy and SIMS indicate that BN-coatings containing c-BN were deposited. However a final verification of c-BN crystallites by TEM investigations was not possible till now. (nevyjel)

  11. High-beta plasma effects in a low-pressure helicon plasma

    International Nuclear Information System (INIS)

    Corr, C. S.; Boswell, R. W.

    2007-01-01

    In this work, high-beta plasma effects are investigated in a low-pressure helicon plasma source attached to a large volume diffusion chamber. When operating above an input power of 900 W and a magnetic field of 30 G a narrow column of bright blue light (due to Ar II radiation) is observed along the axis of the diffusion chamber. With this blue mode, the plasma density is axially very uniform in the diffusion chamber; however, the radial profiles are not, suggesting that a large diamagnetic current might be induced. The diamagnetic behavior of the plasma has been investigated by measuring the temporal evolution of the magnetic field (B z ) and the plasma kinetic pressure when operating in a pulsed discharge mode. It is found that although the electron pressure can exceed the magnetic field pressure by a factor of 2, a complete expulsion of the magnetic field from the plasma interior is not observed. In fact, under our operating conditions with magnetized ions, the maximum diamagnetism observed is ∼2%. It is observed that the magnetic field displays the strongest change at the plasma centre, which corresponds to the maximum in the plasma kinetic pressure. These results suggest that the magnetic field diffuses into the plasma sufficiently quickly that on a long time scale only a slight perturbation of the magnetic field is ever observed

  12. Self-organized pattern on the surface of a metal anode in low-pressure DC discharge

    Science.gov (United States)

    Yaqi, YANG; Weiguo, LI

    2018-03-01

    Self-organization phenomena on the surface of a metal electrode in low-pressure DC discharge is studied. In this paper, we carry out laboratory investigations of self-organization in a low-pressure test platform for 100-200 mm rod-plane gaps with a needle tip, conical tip and hemispherical tip within 1-10 kPa. The factors influencing the pattern profile are the pressure value, gap length and shape of the electrode, and a variety of pattern structures are observed by changing these factors. With increasing pressure, first the pattern diameter increases and then decreases. With the needle tip, layer structure, single-ring structure and double-ring structure are displayed successively with increasing pressure. With the conical tip, the ring-like structure gradually forms separate spots with increasing pressure. With the hemispherical tip, there are anode spots inside the ring structure. With the increase of gap length, the diameter of the self-organized pattern increases and the profile of the pattern changes. The development process of the pattern contains three key stages: pattern enlargement, pattern stabilization and pattern shrink.

  13. JINR rapid communications

    International Nuclear Information System (INIS)

    1999-01-01

    The present collection of rapid communications from JINR, Dubna, contains seven separate records on yields of the rare-earth neutron-deficient isotopes in the reactions of Mo isotopes with 40 Ca ions, observations of slow components of solitonic-type wave structure excited by e-beam in massive copper sample, development and investigation of low-mass multilayer drift chambers (MDC-2) for inner part of the HADES spectrometer, temperature measurement of the uranium sample irradiated with secondary neutrons, edge effects in multiwire proportional chambers, the influence of the dielectric frame, an object-oriented framework for the hadronic Monte-Carlo event generators and uranium-238 as a source for electronuclear power production. 32 figs., 3 tabs

  14. Blood pressure response to conventional and low-dose enalapril in chronic renal failure

    DEFF Research Database (Denmark)

    Elung-Jensen, Thomas; Heisterberg, Jens; Kamper, Anne-Lise

    2003-01-01

    AIMS: In chronic renal failure, the clearance of most ACE inhibitors including enalapril is reduced. Hence, with conventional dosage, plasma enalaprilat may be markedly elevated. It is unclear whether this excess of drug exposure affords an improved control of blood pressure. The aim of the present...... study was to evaluate short-term blood pressure response to two different plasma levels of enalaprilat. METHODS: As part of an open, randomized, controlled trial of the effect of high and low dosage of enalapril on the progression of renal failure, short-term blood pressure response was evaluated. Data...

  15. Low-temperature specific heat of the β-pyrochlore oxide superconductors under high pressure

    Science.gov (United States)

    Isono, T.; Iguchi, D.; Machida, Y.; Izawa, K.; Salce, B.; Flouquet, J.; Ogusu, H.; Yamaura, J.; Hiroi, Z.

    2011-01-01

    We report the results of the low-temperature specific heat measurements of the single crystalline β-pyrochlore oxide superconductors AOs 2O 6 (A=K, Rb, and Cs) under high pressure up to 13 GPa. We find that superconducting transition temperature ( Tc) monotonically increases for CsOs 2O 6 and RbOs 2O 6, while the one for KOs 2O 6 decreases by applying the pressure. With further increasing the pressure, Tc is suddenly suppressed at the same lattice volume for all compounds, concomitant with the first-order structural phase transition.

  16. Investigation on Active Thermal Control Method with Pool Boiling Heat Transfer at Low Pressure

    Science.gov (United States)

    Sun, Chuang; Guo, Dong; Wang, Zhengyu; Sun, Fengxian

    2018-06-01

    In order to maintain a desirable temperature level of electronic equipment at low pressure, the thermal control performance with pool boiling heat transfer of water was examined based on experimental measurement. The total setup was designed and performed to accomplish the experiment with the pressure range from 4.5 kPa to 20 kPa and the heat flux between 6 kW/m2 and 20 kW/m2. The chosen material of the heat surface was aluminium alloy and the test cavity had the capability of varying the direction for the heat surface from vertical to horizontal directions. Through this study, the steady and transient temperature of the heat surface at different pressures and directions were obtained. Although the temperature non-uniformity of the heat surface from the centre to the edge could reach 10°C for the aluminium alloy due to the varying pressures, the whole temperature results successfully satisfied with the thermal control requirements for electronic equipment, and the temperature control effect of the vertically oriented direction was better than that of the horizontally oriented direction. Moreover, the behaviour of bubbles generating and detaching from the heat surface was recorded by a high-resolution camera, so as to understand the pool boiling heat transfer mechanism at low-load heat flux. These pictures showed that the bubbles departure diameter becomes larger, and departure frequency was slower at low pressure, in contrast to 1.0 atm.

  17. Ammonia-lithium nitrate absorption chiller with an integrated low-pressure compression booster cycle for low driving temperatures

    International Nuclear Information System (INIS)

    Ventas, R.; Lecuona, A.; Zacarias, A.; Venegas, M.

    2010-01-01

    Single-effect absorption refrigeration hybridized with mechanical vapor compression in a vapor circuit is known as the absorption cycle with an integrated booster compressor. In this study, the compressor is located between the evaporator and the absorber. This paper presents a numerical model of this cycle with ammonia-lithium nitrate solution as the working pair. It is based on UA-ΔT lm models for separate regions of plate-type heat exchangers. The results are offered as a function of external circuit flow parameters. Different pressure ratios of the compressor were tested for a wide range of hot water driving temperatures (55-95 deg. C), showing that low values are more beneficial. This cycle allows for working at lower driving temperatures than the single-effect cycle, with low electricity consumption. At the same driving temperature, the capacity is augmented with an increased compressor pressure ratio, thus allowing for demand matching of the cooling. This cycle, operating with hot water at 67 deg. C with a pressure ratio of 2.0, has the capacity of a single-effect absorption cycle at 94 deg. C. The electrical COP was found to be higher than that in an ammonia vapor compression cycle for comprehensive working conditions.

  18. Low cycle fatigue numerical estimation of a high pressure turbine disc for the AL-31F jet engine

    Directory of Open Access Journals (Sweden)

    Spodniak Miroslav

    2017-01-01

    Full Text Available This article deals with the description of an approximate numerical estimation approach of a low cycle fatigue of a high pressure turbine disc for the AL-31F turbofan jet engine. The numerical estimation is based on the finite element method carried out in the SolidWorks software. The low cycle fatigue assessment of a high pressure turbine disc was carried out on the basis of dimensional, shape and material disc characteristics, which are available for the particular high pressure engine turbine. The method described here enables relatively fast setting of economically feasible low cycle fatigue of the assessed high pressure turbine disc using a commercially available software. The numerical estimation of accuracy of a low cycle fatigue depends on the accuracy of required input data for the particular investigated object.

  19. Sudden Disappearance of the First-Order Transition in β-Pyrochlore KOs2O6 under Low Pressure

    Science.gov (United States)

    Umeo, Kazunori; Kubo, Hirokazu; Yamaura, Jun-ichi; Hiroi, Zenji; Takabatake, Toshiro

    2009-12-01

    We report the first observation of the pressure effect on the first-order transition at Tp = 7.5 K in the β-pyrochlore oxide superconductor KOs2O6 by specific-heat measurement. The peak in the specific heat at Tp disappeared at a low pressure of 0.02 GPa. With increasing pressure up to 0.02 GPa, the coefficient of the T5 dependence of the specific heat increases by 30%. This finding implies that low-energy excitations of phonons are enhanced by the suppression of the first-order transition. However, the specific-heat jump at Tc is unchanged with pressure up to 1 GPa, indicating that the strong coupling superconductivity is rather robust under pressure.

  20. Weight Status and High Blood Pressure Among Low-Income African American Men

    Science.gov (United States)

    Bruce, Marino A.; Beech, Bettina M.; Edwards, Christopher L.; Sims, Mario; Scarinci, Isabel; Whitfield, Keith E.; Gilbert, Keon; Crook, Errol D.

    2016-01-01

    Obesity is a biological risk factor or comorbidity that has not received much attention from scientists studying hypertension among African American men. The purpose of this study was to examine the relationship between weight status and high blood pressure among African American men with few economic resources. The authors used surveillance data collected from low-income adults attending community- and faith-based primary care clinics in West Tennessee to estimate pooled and group-specific regression models of high blood pressure. The results from group-specific logistic regression models indicate that the factors associated with hypertension varied considerably by weight status. This study provides a glimpse into the complex relationship between weight status and high blood pressure status among African American men. Additional research is needed to identify mechanisms through which excess weight affects the development and progression of high blood pressure. PMID:20937738

  1. In-reactor oxidation of zircaloy-4 under low water vapor pressures

    Science.gov (United States)

    Luscher, Walter G.; Senor, David J.; Clayton, Kevin K.; Longhurst, Glen R.

    2015-01-01

    Complementary in- and ex-reactor oxidation tests have been performed to evaluate the oxidation and hydrogen absorption performance of Zircaloy-4 (Zr-4) under relatively low partial pressures (300 and 1000 Pa) of water vapor at specified test temperatures (330 and 370 °C). Data from these tests will be used to support the fabrication of components intended for isotope-producing targets and provide information regarding the temperature and pressure dependence of oxidation and hydrogen absorption of Zr-4 over the specified range of test conditions. Comparisons between in- and ex-reactor test results were performed to evaluate the influence of irradiation.

  2. In-reactor oxidation of zircaloy-4 under low water vapor pressures

    International Nuclear Information System (INIS)

    Luscher, Walter G.; Senor, David J.; Clayton, Kevin K.; Longhurst, Glen R.

    2015-01-01

    Complementary in- and ex-reactor oxidation tests have been performed to evaluate the oxidation and hydrogen absorption performance of Zircaloy-4 (Zr-4) under relatively low partial pressures (300 and 1000 Pa) of water vapor at specified test temperatures (330 and 370 ℃). Data from these tests will be used to support the fabrication of components intended for isotope-producing targets and provide information regarding the temperature and pressure dependence of oxidation and hydrogen absorption of Zr- 4 over the specified range of test conditions. Comparisons between in- and ex-reactor test results were performed to evaluate the influence of irradiation.

  3. A new humane method of stunning broilers using low atmospheric pressure

    Science.gov (United States)

    This research project evaluated an alternative method of controlled atmosphere stunning of commercial broilers to induce anoxia utilizing a vacuum pump to reduce the oxygen tension, low atmospheric pressure stun (LAPS). A custom built 2 cage-module system (holding a total of 600 broilers each) with...

  4. Fuzzy logic control for improved pressurizer systems in nuclear power plants

    International Nuclear Information System (INIS)

    Brown, Chris; Gabbar, Hossam A.

    2014-01-01

    Highlights: • Improved performance of the pressurizer system in a CANDU nuclear power plant (NPP). • Inventory control for the pressurizer system in NPP. • Compare fuzzy logic with PID in pressurizer system in NPP. • Develop a fuzzy controller to regulate the pressurizer inventory control. • Compare control performance with current proportional controller used at NPP. - Abstract: The pressurizer system in a CANDU nuclear power plant is responsible for maintaining the pressure of the primary heat transport system to ensure the plant is operated within its safe operating envelope. The inventory control for the pressurizer system use a combination of level sensors, feed valves and bleed valves to ensure that there is adequate room in the pressurizer to accommodate any swell or shrinkage in the PHT system. The Darlington Nuclear Generating Station (DNGS) in Ontario, Canada currently uses a proportional controller for the bleed and feed valves to regulate the pressurizer inventory control which can result in large coolant level overshoot along with excessive settling times. The purpose of this paper is to develop a fuzzy controller to regulate the pressurizer inventory control and compare its performance to the current proportional controller used at DNGS. The simulation of the pressurizer inventory control system shows the fuzzy controller performs better than the proportional controller in terms of settling time and overshoot

  5. Influences of Duration of Inspiratory Effort, Respiratory Mechanics, and Ventilator Type on Asynchrony With Pressure Support and Proportional Assist Ventilation.

    Science.gov (United States)

    Vasconcelos, Renata S; Sales, Raquel P; Melo, Luíz H de P; Marinho, Liégina S; Bastos, Vasco Pd; Nogueira, Andréa da Nc; Ferreira, Juliana C; Holanda, Marcelo A

    2017-05-01

    Pressure support ventilation (PSV) is often associated with patient-ventilator asynchrony. Proportional assist ventilation (PAV) offers inspiratory assistance proportional to patient effort, minimizing patient-ventilator asynchrony. The objective of this study was to evaluate the influence of respiratory mechanics and patient effort on patient-ventilator asynchrony during PSV and PAV plus (PAV+). We used a mechanical lung simulator and studied 3 respiratory mechanics profiles (normal, obstructive, and restrictive), with variations in the duration of inspiratory effort: 0.5, 1.0, 1.5, and 2.0 s. The Auto-Trak system was studied in ventilators when available. Outcome measures included inspiratory trigger delay, expiratory trigger asynchrony, and tidal volume (V T ). Inspiratory trigger delay was greater in the obstructive respiratory mechanics profile and greatest with a effort of 2.0 s (160 ms); cycling asynchrony, particularly delayed cycling, was common in the obstructive profile, whereas the restrictive profile was associated with premature cycling. In comparison with PSV, PAV+ improved patient-ventilator synchrony, with a shorter triggering delay (28 ms vs 116 ms) and no cycling asynchrony in the restrictive profile. V T was lower with PAV+ than with PSV (630 mL vs 837 mL), as it was with the single-limb circuit ventilator (570 mL vs 837 mL). PAV+ mode was associated with longer cycling delays than were the other ventilation modes, especially for the obstructive profile and higher effort values. Auto-Trak eliminated automatic triggering. Mechanical ventilation asynchrony was influenced by effort, respiratory mechanics, ventilator type, and ventilation mode. In PSV mode, delayed cycling was associated with shorter effort in obstructive respiratory mechanics profiles, whereas premature cycling was more common with longer effort and a restrictive profile. PAV+ prevented premature cycling but not delayed cycling, especially in obstructive respiratory mechanics

  6. Heat transfer measurements on an incidence-tolerant low pressure turbine blade in a high speed linear cascade at low to moderate Reynolds numbers

    Science.gov (United States)

    Moualeu, Leolein Patrick Gouemeni

    Runway-independent aircraft are expected to be the future for short-haul flights by improving air transportation and reducing area congestion encountered in airports. The Vehicle Systems Program of NASA identified a Large Civil Tilt-Rotor, equipped with variable-speed power-turbine engines, as the best concept. At cruise altitude, the engine rotor-speed will be reduced by as much as the 50% of take-off speed. The large incidence variation in the low pressure turbine associated with the change in speed can be detrimental to the engine performance. Low pressure turbine blades in cruise altitude are more predisposed to develop regions of boundary layer separation. Typical phenomenon such as impinging wakes on downstream blades and mainstream turbulences enhance the complexity of the flow in low pressure turbines. It is therefore important to be able to understand the flow behavior to accurately predict the losses. Research facilities are seldom able to experimentally reproduce low Reynolds numbers at relevant engine Mach number. Having large incidence swing as an additional parameter in the investigation of the boundary layer development, on a low pressure turbine blade, makes this topic unique and as a consequence requires a unique facility to conduct the experimental research. The compressible flow wind tunnel facility at the University of North Dakota had been updated to perform steady state experiments on a modular-cascade, designed to replicate a large variation of the incidence angles. The high speed and low Reynolds number facility maintained a sealed and closed loop configuration for each incidence angle. The updated facility is capable to produce experimental Reynolds numbers as low as 45,000 and as high as 570,000 at an exit Mach number of 0.72. Pressure and surface temperature measurements were performed at these low pressure turbine conditions. The present thesis investigates the boundary layer development on the surface of an Incidence-tolerant blade. The

  7. Design of passive decay heat removal system using thermosyphon for low temperature and low pressure pool type LWR

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jangsik; You, Byung Hyun; Jung, Yong Hun; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2013-10-15

    In seawater desalination process which doesn't need high temperature steam, the reactor has profitability. KAIST has be developing the new reactor design, AHR400, for only desalination. For maximizing safety, the reactor requires passive decay heat removal system. In many nuclear reactors, DHR system is loop form. The DHR system can be designed simple by applying conventional thermosyphon, which is fully passive device, shows high heat transfer performance and simple structure. DHR system utilizes conventional thermosyphon and its heat transfer characteristics are analyzed for AHR400. For maximizing safety of the reactor, passive decay heat removal system are prepared. Thermosyphon is useful device for DHR system of low pressure and low temperature pool type reactor. Thermosyphon is operated fully passive and has simple structure. Bundle of thermosyphon get the goal to prohibit boiling in reactor and high pressure in reactor vessel.

  8. Thermal-hydraulic oscillations in a low pressure two-phase natural circulation loop at low powers and high inlet subcoolings

    International Nuclear Information System (INIS)

    Wang, S.B.; Wu, J.Y.; Chin Pan; Lin, W.K.

    2004-01-01

    The stability of a natural circulation boiling loop is of great importance and interests for both academic researches and many industrial applications, such as next generation boiling water reactors. The present study investigated the thermal-hydraulic oscillation behavior in a low pressure two-phase natural circulation loop at low powers and high inlet subcoolings. The experiments were conducted at atmospheric pressure with heating power ranging from 4 to 8 kW and inlet subcooling ranging from 27 to 75 deg. C. Significant oscillations in loop mass flow rate, pressure drop in each section, and heated wall and fluid temperatures are present for all the cases studied here. The oscillation is typically quasi-periodic and with flow reversal with magnitudes smaller than forward flows. The magnitude of wall temperature oscillation could be as high as 60 deg. C, which will be of serious concern for practical applications. It is found that the first fundamental oscillation (large magnitude oscillation) frequency increases with increase in heated power and with decrease in inlet subcooling. (author)

  9. Chaotic oscillations in a low pressure two-phase natural circulation loop under low power and high inlet subcooling conditions

    International Nuclear Information System (INIS)

    Wu, C.Y.; Wang, S.B.; Pan, C.

    1996-01-01

    The oscillation characteristics of a low pressure two-phase natural circulation loop have been investigated experimentally in this study. Experimental results indicate that the characteristics of the thermal hydraulic oscillations can be periodic, with 2-5 fundamental frequencies, or chaotic, depending on the heating power and inlet subcooling. The number of fundamental frequencies of oscillation increases if the inlet subcooling is increased at a given heating power or the heating power is decreased at a given inlet subcooling; chaotic oscillations appear if the inlet subcooling is further increased and/or the heating power is further decreased. A map of the oscillation characteristics is thus established. The change in oscillation characteristics is evident from the time evolution and power spectrum of a thermal hydraulic parameter and the phase portraits of two thermal hydraulic parameters. These results reveal that a strange attractor exists in a low pressure two-phase natural circulation loop with low power and very high inlet subcooling. (orig.)

  10. Limited-angle imaging in positron cameras: theory and practice

    Energy Technology Data Exchange (ETDEWEB)

    Tam, K.C.

    1979-10-01

    The principles of operation of planar positron camera systems made up of multiwire proportional chambers as detectors and electromagnetic delay lines for coordinate readout are discussed. Gamma converters are coupled to the wire chambers to increase detection efficiency and improve spatial resolution. The conversion efficiencies of these converters are calculated and the results compare favorably to the experimentally measured values.

  11. Limited-angle imaging in positron cameras: theory and practice

    International Nuclear Information System (INIS)

    Tam, K.C.

    1979-10-01

    The principles of operation of planar positron camera systems made up of multiwire proportional chambers as detectors and electromagnetic delay lines for coordinate readout are discussed. Gamma converters are coupled to the wire chambers to increase detection efficiency and improve spatial resolution. The conversion efficiencies of these converters are calculated and the results compare favorably to the experimentally measured values

  12. A PET scanner developed by CERN

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This image shows a Position Emission Tomography (PET) scanner at the Hopital Cantonal Universitaire de Genève. Development of the multiwire proportional chamber at CERN in the mid-1970s was soon seen as a potential device for medical imaging. It is much more sensitive than previous devices and greatly reduced the dose of radiation received by the patient.

  13. An algorithm for three-dimensional imaging in the positron camera

    International Nuclear Information System (INIS)

    Chen Kun; Ma Mei; Xu Rongfen; Shen Miaohe

    1986-01-01

    A mathematical algorithm of back-projection filtered for image reconstructions using two-dimensional signals detected from parallel multiwire proportional chambers is described. The approaches of pseudo three-dimensional and full three-dimensional image reconstructions are introduced, and the available point response functions are defined as well. The designing parameters and computation procedure of the full three-dimensional method is presented

  14. A solenoidal electron spectrometer for a precision measurement of the neutron β-asymmetry with ultracold neutrons

    International Nuclear Information System (INIS)

    Plaster, B.; Carr, R.; Filippone, B.W.; Harrison, D.; Hsiao, J.; Ito, T.M.; Liu, J.; Martin, J.W.; Tipton, B.; Yuan, J.

    2008-01-01

    We describe an electron spectrometer designed for a precision measurement of the neutron β-asymmetry with spin-polarized ultracold neutrons. The spectrometer consists of a 1.0-T solenoidal field with two identical multiwire proportional chamber and plastic scintillator electron detector packages situated within 0.6-T field-expansion regions. Select results from performance studies of the spectrometer with calibration sources are reported

  15. A solenoidal electron spectrometer for a precision measurement of the neutron {beta}-asymmetry with ultracold neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Plaster, B. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Department of Physics and Astronomy, University of Kentucky, Lexington, KY 40506 (United States)], E-mail: plaster@pa.uky.edu; Carr, R.; Filippone, B.W. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Harrison, D. [Physics Department, University of Winnipeg, Manitoba, Canada R3B 2E9 (Canada); Hsiao, J. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Ito, T.M. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Liu, J. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Martin, J.W. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States); Physics Department, University of Winnipeg, Manitoba, R3B 2E9 (Canada); Tipton, B.; Yuan, J. [W.K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, CA 91125 (United States)

    2008-10-11

    We describe an electron spectrometer designed for a precision measurement of the neutron {beta}-asymmetry with spin-polarized ultracold neutrons. The spectrometer consists of a 1.0-T solenoidal field with two identical multiwire proportional chamber and plastic scintillator electron detector packages situated within 0.6-T field-expansion regions. Select results from performance studies of the spectrometer with calibration sources are reported.

  16. Insects at low pressure: applications to artificial ecosystems and implications for global windborne distribution

    Science.gov (United States)

    Cockell, C.; Catling, D.; Waites, H.

    1999-01-01

    Insects have a number of potential roles in closed-loop life support systems. In this study we examined the tolerance of a range of insect orders and life stages to drops in atmospheric pressure using a terrestrial atmosphere. We found that all insects studied could tolerate pressures down to 100 mb. No effects on insect respiration were noted down to 500 mb. Pressure toleration was not dependent on body volume. Our studies demonstrate that insects are compatible with plants in low-pressure artificial and closed-loop ecosystems. The results also have implications for arthropod colonization and global distribution on Earth.

  17. The development of an auto-sealing system using an electrically shrinkable tube under a low-pressure condition

    Energy Technology Data Exchange (ETDEWEB)

    Okano, Yoshihiro; Kitagawa, Takao [NKK Corp, Tsu, Mie (Japan); Shoji, Norio [NKK Corp., Yokohama (Japan); Namioka, Toshiyuki [Nippon Kokan Koji Corp., Yokohama (Japan). Research and Development Dept.; Komura, Minoru [Nitto Denko Corp., Fukaya, Saitama (Japan)

    1997-04-01

    This article describes the development of a system to create high quality, automatic sealing of field joints of polyethylene coated pipelines. The system uses a combination of an electrically heated shrinkable tube and a low-pressure chamber. The self-heating shrinkable tube includes electric heater wires that heat when connected to electricity. A method was developed to eliminate air trapped between the tube and the steel pipe by shrinking the tube under a low-pressure condition. The low-pressure condition was automatic and easily attained by using a vacuum chamber. It was verified that the system produced high quality sealing of the field joints.

  18. Data needs for diagnostics of low pressure plasmas

    International Nuclear Information System (INIS)

    Graham, Bill

    2000-01-01

    The low pressure plasma processing environment is complex and presents many diagnostic challenges. Here the diagnostic techniques used for accurate and detailed measurement of the density and energy distributions of charged and neutral species are reviewed. Most of the techniques rely heavily on atomic and molecular data. The specific data needs of each diagnostic are outlined. It is shown that in total these data needs are vast and diverse and cannot all be met from specific measurements or calculations. The real need is for generic scaling rules for each of the significant atomic and molecular processes

  19. On the Validity of Continuum Computational Fluid Dynamics Approach Under Very Low-Pressure Plasma Spray Conditions

    Science.gov (United States)

    Ivchenko, Dmitrii; Zhang, Tao; Mariaux, Gilles; Vardelle, Armelle; Goutier, Simon; Itina, Tatiana E.

    2018-01-01

    Plasma spray physical vapor deposition aims to substantially evaporate powders in order to produce coatings with various microstructures. This is achieved by powder vapor condensation onto the substrate and/or by deposition of fine melted powder particles and nanoclusters. The deposition process typically operates at pressures ranging between 10 and 200 Pa. In addition to the experimental works, numerical simulations are performed to better understand the process and optimize the experimental conditions. However, the combination of high temperatures and low pressure with shock waves initiated by supersonic expansion of the hot gas in the low-pressure medium makes doubtful the applicability of the continuum approach for the simulation of such a process. This work investigates (1) effects of the pressure dependence of thermodynamic and transport properties on computational fluid dynamics (CFD) predictions and (2) the validity of the continuum approach for thermal plasma flow simulation under very low-pressure conditions. The study compares the flow fields predicted with a continuum approach using CFD software with those obtained by a kinetic-based approach using a direct simulation Monte Carlo method (DSMC). It also shows how the presence of high gradients can contribute to prediction errors for typical PS-PVD conditions.

  20. Design Concepts for Low Aspect Ratio High Pressure Turbines for High Bypass Ratio Turbofans, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The performance gains and weight reductions from using Ceramic Matrix Composite(CMC) turbine blades in both the High Pressure Turbine(HPT) and Low Pressure...

  1. The RF voltage dependence of the electron sheath heating in low pressure capacitively coupled rf discharges

    International Nuclear Information System (INIS)

    Buddemeier, U.; Kortshagen, U.; Pukropski, I.

    1995-01-01

    In low pressure capacitively coupled RF discharges two competitive electron heating mechanisms have been discussed for some time now. At low pressures the stochastic sheath heating and for somewhat higher pressures the Joule heating in the bulk plasma have been proposed. When the pressure is increased at constant RF current density a transition from concave electron distribution functions (EDF) with a pronounced cold electron group to convex EDFs with a missing strong population of cold electrons is found. This transition was interpreted as the transition from dominant stochastic to dominant Joule heating. However, a different interpretation has been given by Kaganovich and Tsendin, who attributed the concave shaped EDFs to the spatially inhomogeneous RF field in combination with the nonlocality of the EDF

  2. Correlation between Balmer α emission and hydrogen flux through a superpermeable niobium membrane in a low-pressure multicusp plasma source

    International Nuclear Information System (INIS)

    Bruneteau, A.M.; Notkin, M.E.; Livshits, A.I.; Bacal, M.

    2002-01-01

    The purpose of this paper is to correlate hydrogen or deuterium flux through super permeable membranes with incident hydrogen or deuterium atom flux from the plasma. To this aim a hydrogen or deuterium plasma is created in a hybrid multicusp plasma source. We investigate Balmer α emission from the multicusp plasma and the output pressure behind a superpermeable niobium membrane immersed in the plasma.The output pressure is proportional to the flux of atoms and ions arriving on the membrane. We find that both output pressure and excited atoms emission satisfy plasma parameters relations. It is thus verified that plasma-driven superpermeation of hydrogen is due essentially to neutral atoms from the plasma incident to the membrane

  3. Design and Application of a High Sensitivity Piezoresistive Pressure Sensor for Low Pressure Conditions

    Science.gov (United States)

    Yu, Huiyang; Huang, Jianqiu

    2015-01-01

    In this paper, a pressure sensor for low pressure detection (0.5 kPa–40 kPa) is proposed. In one structure (No. 1), the silicon membrane is partly etched to form a crossed beam on its top for stress concentration. An aluminum layer is also deposited as part of the beam. Four piezoresistors are fabricated. Two are located at the two ends of the beam. The other two are located at the membrane periphery. Four piezoresistors connect into a Wheatstone bridge. To demonstrate the stress concentrate effect of this structure, two other structures were designed and fabricated. One is a flat membrane structure (No. 2), the other is a structure with the aluminum beam, but without etched silicon (No. 3). The measurement results of these three structures show that the No.1 structure has the highest sensitivity, which is about 3.8 times that of the No. 2 structure and 2.7 times that of the No. 3 structure. They also show that the residual stress in the beam has some backside effect on the sensor performance. PMID:26371001

  4. Fiber Optic Pressure Sensor using Multimode Interference

    International Nuclear Information System (INIS)

    Ruiz-Perez, V I; Sanchez-Mondragon, J J; Basurto-Pensado, M A; LiKamWa, P; May-Arrioja, D A

    2011-01-01

    Based on the theory of multimode interference (MMI) and self-image formation, we developed a novel intrinsic optical fiber pressure sensor. The sensing element consists of a section of multimode fiber (MMF) without cladding spliced between two single mode fibers (SMF). The MMI pressure sensor is based on the intensity changes that occur in the transmitted light when the effective refractive index of the MMF is changed. Basically, a thick layer of Polydimethylsiloxane (PDMS) is placed in direct contact with the MMF section, such that the contact area between the PDMS and the fiber will change proportionally with the applied pressure, which results in a variation of the transmitted light intensity. Using this configuration, a good correlation between the measured intensity variations and the applied pressure is obtained. The sensitivity of the sensor is 3 μV/psi, for a range of 0-60 psi, and the maximum resolution of our system is 0.25 psi. Good repeatability is also observed with a standard deviation of 0.0019. The key feature of the proposed pressure sensor is its low fabrication cost, since the cost of the MMF is minimal.

  5. Fiber Optic Pressure Sensor using Multimode Interference

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Perez, V I; Sanchez-Mondragon, J J [INAOE, Apartado Postal 51 y 216, Puebla 72000 (Mexico); Basurto-Pensado, M A [CIICAp, Universidad Autonoma del Estado de Morelos (Mexico); LiKamWa, P [CREOL, University of Central Florida, Orlando, FL 32816 (United States); May-Arrioja, D A, E-mail: iruiz@inaoep.mx, E-mail: mbasurto@uaem.mx, E-mail: delta_dirac@hotmail.com, E-mail: daniel_may_arrioja@hotmail.com [UAT Reynosa Rodhe, Universidad Autonoma de Tamaulipas (Mexico)

    2011-01-01

    Based on the theory of multimode interference (MMI) and self-image formation, we developed a novel intrinsic optical fiber pressure sensor. The sensing element consists of a section of multimode fiber (MMF) without cladding spliced between two single mode fibers (SMF). The MMI pressure sensor is based on the intensity changes that occur in the transmitted light when the effective refractive index of the MMF is changed. Basically, a thick layer of Polydimethylsiloxane (PDMS) is placed in direct contact with the MMF section, such that the contact area between the PDMS and the fiber will change proportionally with the applied pressure, which results in a variation of the transmitted light intensity. Using this configuration, a good correlation between the measured intensity variations and the applied pressure is obtained. The sensitivity of the sensor is 3 {mu}V/psi, for a range of 0-60 psi, and the maximum resolution of our system is 0.25 psi. Good repeatability is also observed with a standard deviation of 0.0019. The key feature of the proposed pressure sensor is its low fabrication cost, since the cost of the MMF is minimal.

  6. The effect of low-Dye taping on plantar pressures, during gait, in subjects with navicular drop exceeding 10 mm.

    Science.gov (United States)

    Lange, Belinda; Chipchase, Lucy; Evans, Angela

    2004-04-01

    A preintervention and postintervention, repeated-measures experimental design. To investigate the immediate effect of low-Dye taping on peak and mean plantar pressures during gait in subjects with navicular drop exceeding 10 mm. Low-Dye taping is commonly used to support the longitudinal and transverse arches of the foot in an attempt to reduce the effects of symptoms associated with excessive pronation. Plantar pressure measurement has been used as an indirect indicator of pronation during gait. METHOD AND MEASURES: The right foot of 60 subjects was tested using the Emed-AT system to obtain plantar pressure values. Subjects performed 6 barefoot walks over the Emed pressure platform while taped and a further 6 walks while untaped. Plantar pressures were recorded. Each footprint obtained was divided into 10 sections or 'masks.' Average peak and mean plantar pressure values (N/cm2) were calculated for both taped and untaped walks for each mask. Paired t tests demonstrated significant changes in peak plantar pressure in 8 of the 10 areas of the foot and significant changes in mean plantar pressure in 9 of the 10 areas of the foot. Low-Dye taping significantly decreased pressure under the heel and the medial and middle forefoot, while increasing pressure under the lateral midfoot and under the toes. A significant decrease in mean plantar pressure was observed under the lateral forefoot, while no significant difference was demonstrated in peak plantar pressure under this area. The area under the medial midfoot demonstrated no significant change in either peak or mean pressure. Low-Dye taping significantly altered peak and mean plantar pressure values in subjects with navicular drop exceeding 10 mm. In particular, peak and mean plantar pressure increased under the lateral midfoot and under the toes, and decreased under the heel and forefoot, suggesting that a decrease in the amount of pronation occurred.

  7. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    LENUS (Irish Health Repository)

    Nolan, Damien

    2009-01-01

    BACKGROUND: Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape\\'s immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. METHODS: 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. RESULTS: Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. CONCLUSION: Low-Dye tape\\'s initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued

  8. Effects of ambient temperature and water vapor on chamber pressure and oxygen level during low atmospheric pressure stunning of poultry.

    Science.gov (United States)

    Holloway, Paul H; Pritchard, David G

    2017-08-01

    The characteristics of the vacuum used in a low atmospheric pressure stunning system to stun (render unconscious) poultry prior to slaughter are described. A vacuum chamber is pumped by a wet screw compressor. The vacuum pressure is reduced from ambient atmospheric pressure to an absolute vacuum pressure of ∼250 Torr (∼33 kPa) in ∼67 sec with the vacuum gate valve fully open. At ∼250 Torr, the sliding gate valve is partially closed to reduce effective pumping speed, resulting in a slower rate of decreasing pressure. Ambient temperature affects air density and water vapor pressure and thereby oxygen levels and the time at the minimum total pressure of ∼160 Torr (∼21 kPa) is varied from ∼120 to ∼220 sec to ensure an effective stun within the 280 seconds of each cycle. The reduction in total pressure results in a gradual reduction of oxygen partial pressure that was measured by a solid-state electrochemical oxygen sensor. The reduced oxygen pressure leads to hypoxia, which is recognized as a humane method of stunning poultry. The system maintains an oxygen concentration of air always reduces the oxygen concentrations to a value lower than in dry air. The partial pressure of water and oxygen were found to depend on the pump down parameters due to the formation of fog in the chamber and desorption of water from the birds and the walls of the vacuum chamber. © The Author 2017. Published by Oxford University Press on behalf of Poultry Science Association.

  9. Low-pressure phase diagram of crystalline benzene from quantum Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Azadi, Sam, E-mail: s.azadi@ucl.ac.uk [Departments of Physics and Astronomy, University College London, Thomas Young Center, London Centre for Nanotechnology, London WC1E 6BT (United Kingdom); Cohen, R. E. [Extreme Materials Initiative, Geophysical Laboratory, Carnegie Institution for Science, Washington, DC 20015 (United States); Department of Earth- and Environmental Sciences, Ludwig Maximilians Universität, Munich 80333 (Germany); Department of Physics and Astronomy, University College London, London WC1E 6BT (United Kingdom)

    2016-08-14

    We studied the low-pressure (0–10 GPa) phase diagram of crystalline benzene using quantum Monte Carlo and density functional theory (DFT) methods. We performed diffusion quantum Monte Carlo (DMC) calculations to obtain accurate static phase diagrams as benchmarks for modern van der Waals density functionals. Using density functional perturbation theory, we computed the phonon contributions to the free energies. Our DFT enthalpy-pressure phase diagrams indicate that the Pbca and P2{sub 1}/c structures are the most stable phases within the studied pressure range. The DMC Gibbs free-energy calculations predict that the room temperature Pbca to P2{sub 1}/c phase transition occurs at 2.1(1) GPa. This prediction is consistent with available experimental results at room temperature. Our DMC calculations give 50.6 ± 0.5 kJ/mol for crystalline benzene lattice energy.

  10. Development of hybrid low-pressure MSGC neutron detectors

    International Nuclear Information System (INIS)

    Gebauer, B.; Alimov, S.S.; Klimov, A.Yu.; Levchanovski, F.V.; Litvinenko, E.I.; Nikiforov, A.S.; Prikhodko, V.I.; Richter, G.; Rogov, V.; Schulz, Ch.; Shashkin, V.I.; Wilhelm, M.; Wilpert, Th.

    2004-01-01

    For very high rate and resolution time-resolved experiments at next generation pulsed spallation neutron sources like ESS large-area hybrid low-pressure micro-strip gas chamber detectors are being developed. Due to their thin composite converter foil and exponential gas multiplication commencing at the converter surfaces the detectors are free of parallax, and according to detailed modeling the very high transverse and longitudinal localization accuracies in the conversion and gas multiplication processes allow position and time resolutions of ∼100 μm and 8 cps. This will open up novel applications based on time-of-flight (TOF) and single-event detection with very high dynamic range, replacing integrating CCD and image plate detectors, e.g. in radiography/tomography, TOF Laue diffraction, single crystal diffraction and focusing low-Q SANS. In this conference report new results concerning the technical realization of this detector system are reported in conjunction with a brief summary of the detector principle and with reference to earlier results

  11. Intraoperative and postoperative evaluation of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients

    Directory of Open Access Journals (Sweden)

    Ye-Qiu Li

    2016-01-01

    Full Text Available Objective: To evaluate intraoperative and postoperative condition of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients. Methods: A total of 176 cases of elderly patients (more than 60 years old receiving laparoscopic surgery in our hospital from July 2013 to July 2015 were selected as research subjects and randomly divided into observation group and control group, each group included 88 cases, control group received conventional ventilation strategy, observation group received low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy, and then levels of hemodynamic indexes, respiratory mechanical indexes, serology indexes and cerebral vessel related indexes, etc of two groups were compared. Results: Intraoperative and postoperative heart rate and mean arterial pressure levels of observation group were lower than those of control group, arterial partial pressure of oxygen and oxygenation index levels were higher than those of control group and differences had statistical significance (P<0.05; intraoperative APIP and Pplat values of observation group were lower than those of control group, Cs value was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative serum IL-8 and TNF-α levels of observation group were lower than those of control group, IL-10 level was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative PjvO2, SjvO2 and CjvO2 levels of observation group were higher than those of control group, Da-jvO2 level was lower than that of control group and differences had statistical significance (P<0.05. Conclusions: When elderly patients receive laparoscopic surgery, the use of low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy can stabilize hemodynamic

  12. ASSESSING THE EFFECTIVENESS OF LOW PRESSURE ULTRAVIOLET LIGHT FOR INACTIVATING HELICOBACTER PYLORI

    Science.gov (United States)

    Three strains of Helicobacter pylori were exposed to ultraviolet (UV) light from a low-pressure source to determine log inactivation versus applied fluence. Results indicate that H. pylori is readily inactivated at UV fluences typically used in water treatment r...

  13. Flexible geometry hodoscope using proportional chamber cathode read-out

    International Nuclear Information System (INIS)

    Aubret, C.; Bellefon, A. de; Benoit, P.; Brunet, J.M.; Tristram, G.

    1978-01-01

    The construction of a cathode read-out proportional chamber, used as a low mass hodoscope is described. Results on efficiency, time resolution and space resolution are shown. The associative logic, which permits the use of the chamber as a coplanarity chamber is briefly presented

  14. Experimental Studies of Low-Pressure Turbine Flows and Flow Control. Streamwise Pressure Profiles and Velocity Profiles

    Science.gov (United States)

    Volino, Ralph

    2012-01-01

    This report summarizes research performed in support of the NASA Glenn Research Center (GRC) Low-Pressure Turbine (LPT) Flow Physics Program. The work was performed experimentally at the U.S. Naval Academy faculties. The geometry corresponded to "Pak B" LPT airfoil. The test section simulated LPT flow in a passage. Three experimental studies were performed: (a) Boundary layer measurements for ten baseline cases under high and low freestream turbulence conditions at five Reynolds numbers of 25,000, 50,000, 100,000, 200,000, and 300,000, based on passage exit velocity and suction surface wetted length; (b) Passive flow control studies with three thicknesses of two-dimensional bars, and two heights of three-dimensional circular cylinders with different spanwise separations, at same flow conditions as the 10 baseline cases; (c) Active flow control with oscillating synthetic (zero net mass flow) vortex generator jets, for one case with low freestream turbulence and a low Reynolds number of 25,000. The Passive flow control was successful at controlling the separation problem at low Reynolds numbers, with varying degrees of success from case to case and varying levels of impact at higher Reynolds numbers. The active flow control successfully eliminated the large separation problem for the low Reynolds number case. Very detailed data was acquired using hot-wire anemometry, including single and two velocity components, integral boundary layer quantities, turbulence statistics and spectra, turbulent shear stresses and their spectra, and intermittency, documenting transition, separation and reattachment. Models were constructed to correlate the results. The report includes a summary of the work performed and reprints of the publications describing the various studies.This report summarizes research performed in support of the NASA Glenn Research Center (GRC) Low-Pressure Turbine (LPT) Flow Physics Program. The work was performed experimentally at the U.S. Naval Academy

  15. Characterization of the large area plane-symmetric low-pressure DC glow discharge

    Science.gov (United States)

    Avtaeva, S.; Gorokhovsky, V.; Myers, S.; Robertson, S.; Shunko, E.; Zembower, Z.

    2016-10-01

    Electron density and temperature as well as nitrogen dissociation degree in the low-pressure (10-50 mTorr) large area plane-symmetric DC glow discharge in Ar-N2 mixtures are studied by probes and spectral methods. Electron density measured by a hairpin probe is in good agreement with that derived from the intensity ratio of the N2 2nd positive system bands IC, 1 - 3/IC, 0 - 2 and from the intensity ratio of argon ions and atom lines IArII/IArI, while Langmuir probe data provides slightly higher values of electron density. Electron density in the low-pressure DC glow discharge varies with the discharge conditions in the limits of 108-1010 cm- 3. The concept of electron temperature can be used in low-pressure glow discharges with reservations. The intensity ratio of (0-0) vibrational bands of N2 1st negative and 2nd positive systems I391.4/I337.1 exhibits the electron temperature of 1.5-2.5 eV when argon fraction in the mixture is higher than nitrogen fraction and this ratio quickly increases with nitrogen fraction up to 10 eV in pure nitrogen. The electron temperature calculated from Langmuir probe I-V characteristics assuming a Maxwellian EEDF, gives Te 0.3-0.4 eV. In-depth analysis of the EEDF using the second derivative of Langmuir probe I-V characteristics shows that in a low-pressure glow discharge the EEDF is non-Maxwellian. The EEDF has two populations of electrons: the main background non-Maxwellian population of ;cold; electrons with the mean electron energy of 0.3-0.4 eV and the small Maxwellian population of ;hot; electrons with the mean electron energy of 1.0-2.5 eV. Estimations show that with electron temperature lower than 1 eV the rate of the direct electron impact ionization of N2 is low and the main mechanism of N2 ionization becomes most likely Penning and associative ionization. In this case, assumptions of the intensity ratio IN2+, 391/IN2, 337 method are violated. In the glow discharge, N2 dissociation degree reaches about 7% with the argon

  16. In-situ epitaxial growth of heavily phosphorus doped SiGe by low pressure chemical vapor deposition

    CERN Document Server

    Lee, C J

    1998-01-01

    We have studied epitaxial crystal growth of Si sub 1 sub - sub x Ge sub x films on silicon substrates at 550 .deg. C by low pressure chemical vapor deposition. In a low PH sub 3 partial pressure region such as below 1.25x10 sup - sup 3 Pa, both the phosphorus and carrier concentrations increased with increasing PH sub 3 partial pressure, but the deposition rate and the Ge fraction remained constant. In a higher PH sub 3 partial pressure region, the deposition rate, the phosphorus concentration, and the carrier concentration decreased, while the Ge fraction increased. These suggest that high surface coverage of phosphorus suppresses both SiH sub 4 and GeH sub 4 adsorption/reactions on the surfaces, and its suppression effect on SiH sub 4 is actually much stronger than on GeH sub 4. In particular, epitaxial crystal growth is largely controlled by surface coverage effect of phosphorus in a higher PH sub 3 partial pressure region.

  17. Low pressure injection sequence sensitivity study of the M1 module of MEDICI

    International Nuclear Information System (INIS)

    Corradini, M.L.; Moses, G.A.; Norkus, J.K.; Welzbacker, R.T.

    1985-01-01

    In order to assess the consequences of a PWR containment failure and the ensuing radiological source term following a severe reactor accident, it is necessary to understand the ex-vessel behavior of the molten core. The M1 module of MEDICI models the dynamic fuel-coolant mixing, energetic interaction, and ejection of fuel and coolant from the reactor cavity following such an accident. A sensitivity study of the low pressure injection sequence was performed utilizing a Box-Behnken statistical design to treat five sets of input variables considered to be significant in the mixing and steam explosion processes. The low pressure injection sequence was studied in which the molten corium is modeled as a pour stream entering the cavity without entraining or sweeping out fuel or coolant

  18. Somatosensory nociceptive characteristics differentiate subgroups in people with chronic low back pain: a cluster analysis.

    Science.gov (United States)

    Rabey, Martin; Slater, Helen; OʼSullivan, Peter; Beales, Darren; Smith, Anne

    2015-10-01

    The objectives of this study were to explore the existence of subgroups in a cohort with chronic low back pain (n = 294) based on the results of multimodal sensory testing and profile subgroups on demographic, psychological, lifestyle, and general health factors. Bedside (2-point discrimination, brush, vibration and pinprick perception, temporal summation on repeated monofilament stimulation) and laboratory (mechanical detection threshold, pressure, heat and cold pain thresholds, conditioned pain modulation) sensory testing were examined at wrist and lumbar sites. Data were entered into principal component analysis, and 5 component scores were entered into latent class analysis. Three clusters, with different sensory characteristics, were derived. Cluster 1 (31.9%) was characterised by average to high temperature and pressure pain sensitivity. Cluster 2 (52.0%) was characterised by average to high pressure pain sensitivity. Cluster 3 (16.0%) was characterised by low temperature and pressure pain sensitivity. Temporal summation occurred significantly more frequently in cluster 1. Subgroups were profiled on pain intensity, disability, depression, anxiety, stress, life events, fear avoidance, catastrophizing, perception of the low back region, comorbidities, body mass index, multiple pain sites, sleep, and activity levels. Clusters 1 and 2 had a significantly greater proportion of female participants and higher depression and sleep disturbance scores than cluster 3. The proportion of participants undertaking Low back pain, therefore, does not appear to be homogeneous. Pain mechanisms relating to presentations of each subgroup were postulated. Future research may investigate prognoses and interventions tailored towards these subgroups.

  19. The response of an RC line MWPC to primary cosmic rays. [Multi-Wire Proportional Counter

    Science.gov (United States)

    Gregory, J. C.; Selig, W. J.; Austin, R. W.; Derrickson, J. H.; Parnell, T. A.

    1978-01-01

    A simple 50 x 50 sq cm MWPC plane was arranged as an RC-line and flown on a balloon flight with the MSFC-UAH Cosmic Ray experiment. Positions of primary cosmic ray tracks in the RC-line were determined by the risetime method and compared with the expected position as indicated by a best line fitted through four planes of the conventional MWPC hodoscope. Mean errors were estimated for sea-level muons, and CNO group and iron group particles. It is believed that the delta-rays accompanying the primaries degraded the position resolution. Measured standard deviations allowing for uncertainty in the true track position are of the order of 1 cm or less in the primary charge region between 7 and 26.

  20. Modeling Scala Media as a Pressure Vessel

    Science.gov (United States)

    Lepage, Eric; Olofsson, A.˚Ke

    2011-11-01

    The clinical condition known as endolymphatic hydrops is the swelling of scala media and may result in loss in hearing sensitivity consistent with other forms of low-frequency biasing. Because outer hair cells (OHCs) are displacement-sensitive and hearing levels tend to be preserved despite large changes in blood pressure and CSF pressure, it seems unlikely that the OHC respond passively to changes in static pressures in the chambers. This suggests the operation of a major feedback control loop which jointly regulates homeostasis and hearing sensitivity. Therefore the internal forces affecting the cochlear signal processing amplifier cannot be just motile responses. A complete account of the cochlear amplifier must include static pressures. To this end we have added a third, pressure vessel to our 1-D 140-segment, wave-digital filter active model of cochlear mechanics, incorporating the usual nonlinear forward transduction. In each segment the instantaneous pressure is the sum of acoustic pressure and global static pressure. The object of the model is to maintain stable OHC operating point despite any global rise in pressure in the third chamber. Such accumulated pressure is allowed to dissipate exponentially. In this first 3-chamber implementation we explore the possibility that acoustic pressures are rectified. The behavior of the model is critically dependent upon scaling factors and time-constants, yet by initial assumption, the pressure tends to accumulate in proportion to sound level. We further explore setting of the control parameters so that the accumulated pressure either stays within limits or may rise without bound.

  1. Physiological responses to low atmospheric pressure stunning and the implications for welfare

    NARCIS (Netherlands)

    Mckeegan, D.E.F.; Sandercock, D.A.; Gerritzen, M.A.

    2013-01-01

    In low atmospheric pressure stunning (LAPS), poultry are rendered unconscious before slaughter by gradually reducing oxygen tension in the atmosphere to achieve a progressive anoxia. The effects of LAPS are not instantaneous, so there are legitimate welfare concerns around the experience of birds

  2. Polydiagnostic calibration performed on a low pressure surface wave sustained argon plasma

    NARCIS (Netherlands)

    Vries, de N.; Palomares, J.M.; Iordanova, E.I.; Veldhuizen, van E.M.; Mullen, van der J.J.A.M.

    2008-01-01

    The electron density and electron temperature of a low pressure surface wave sustained argon plasma have been determined using passive and active (laser) spectroscopic methods simultaneously. In this way the validity of the various techniques is established while the plasma properties are determined

  3. Low-pressure glow discharges with oscillating electrons in different electrode systems

    International Nuclear Information System (INIS)

    Bersenev, V.V.; Gavriolv, N.V.; Nikulin, S.P.

    1995-01-01

    One of the main applications of low - pressure glow discharges is the development on their basis of charged - particle beam sources. The use of glow discharges with oscillating electrons, which can operate stably in the voltage and pressure range to the left of the left branch of Pashen's curve, shows promise, because the decrease in critical pressure p 0 , below which the discharge operation becomes impossible, in the discharge system of a source promotes an increase in the electrical strength of its accelerating system. This, in its turn, makes possible the expansion of the operation range of accelerating voltages. This experimental investigation of glow discharges in such well - known systems with oscillating electrons, as Hollow Cathode (HC), Penning's System (PS) and Inverse Magnetron (IM), is aimed at revealing the system operating at the lowest pressure. Besides, both common features and peculiarities of discharge operation in these systems are discussed. Though there is an extensive amount of published information covering all the specified discharges, the carrying out of such investigation is justified, since a comparative analysis of results obtained by different authors is hampered by various conditions of their experiments

  4. Failure prediction of low-carbon steel pressure vessel and cylindrical models

    International Nuclear Information System (INIS)

    Zhang, K.D.; Wang, W.

    1987-01-01

    The failure loads predicted by failure assessment methods (namely the net-section stress criterion; the EPRI engineering approach for elastic-plastic analysis; the CEGB failure assessment route; the modified R6 curve by Milne for strain hardening; and the failure assessment curve based on J estimation by Ainsworth) have been compared with burst test results on externally, axially sharp notched pressure vessel and open-ended cylinder models made from typical low-carbon steel St45 seamless tube which has a transverse true stress-strain curve of straight-line and parabola type and a high value of ultimate strength to yield. It was concluded from the comparison that whilst the net-section stress criterion and the CEGB route did not give conservative predictions, Milne's modified curve did give a conservative and good prediction; Ainsworth's curve gave a fairly conservative prediction; and EPRI solutions also could conditionally give a good prediction but the conditions are still somewhat uncertain. It is suggested that Milne's modified R6 curve is used in failure assessment of low-carbon steel pressure vessels. (author)

  5. Load proportional safety brake

    Science.gov (United States)

    Cacciola, M. J.

    1979-01-01

    This brake is a self-energizing mechanical friction brake and is intended for use in a rotary drive system. It incorporates a torque sensor which cuts power to the power unit on any overload condition. The brake is capable of driving against an opposing load or driving, paying-out, an aiding load in either direction of rotation. The brake also acts as a no-back device when torque is applied to the output shaft. The advantages of using this type of device are: (1) low frictional drag when driving; (2) smooth paying-out of an aiding load with no runaway danger; (3) energy absorption proportional to load; (4) no-back activates within a few degrees of output shaft rotation and resets automatically; and (5) built-in overload protection.

  6. Measurement of Antiproton-proton Cross-Sections at Low Antiproton Momenta

    CERN Multimedia

    2002-01-01

    The experiment is designed to measure four different cross sections in the momentum range 150~MeV/c to 600~MeV/c: 1)~~~~the differential elastic \\\\ \\\\ 2)~~~~the differential charge exchange\\\\ \\\\ 3)~~~~the annihilation into charged and neutral pions\\\\ \\\\ 4)~~~~and the total cross section via the optical theorem. \\\\ \\\\ The experiment allows one to search once again and with good precision for baryonium. Of special interest is the existence of the S-meson, for which a signal of about 20~MeV-mb was found in a 1981 experiment (performed in the East Hall).\\\\ \\\\ A second point of special interest is the momentum region below 300~MeV/c because the cross sections are basically unknown. We will be able to explore the momentum dependence of this region for the first time.\\\\ \\\\ The elastic cross section is measured by a cylindrical multiwire proportional chamber and a scintillator hodoscope placed around a scattering chamber under vacuum. The charge exchange cross section is measured by a ring of 32~anti-neutron detector...

  7. Systems and Methods for Fabricating Structures Including Metallic Glass-Based Materials Using Low Pressure Casting

    Science.gov (United States)

    Hofmann, Douglas C. (Inventor); Kennett, Andrew (Inventor)

    2018-01-01

    Systems and methods to fabricate objects including metallic glass-based materials using low-pressure casting techniques are described. In one embodiment, a method of fabricating an object that includes a metallic glass-based material includes: introducing molten alloy into a mold cavity defined by a mold using a low enough pressure such that the molten alloy does not conform to features of the mold cavity that are smaller than 100 microns; and cooling the molten alloy such that it solidifies, the solid including a metallic glass-based material.

  8. The Ontario hydro low pressure turbine disc inspection program automated ultrasonic inspection systems - an overview

    International Nuclear Information System (INIS)

    Huggins, J.W.; Chopcian, M.; Grabish, M.

    1990-01-01

    An overview of the Ontario Hydro Low Pressure Turbine Disc Inspection Program is presented. The ultrasonic inspection systems developed in-house to inspect low pressure turbine discs at Pickering and Bruce Nuclear Generating stations are described. Three aspects of the program are covered: PART I - Background to inspection program, disc cracking experience, and development of an in-house inspection capability: PART II - System development requirements; ultrasonic equipment, electromechanical subsystems and instrumentation console: PART III - Customized software for flaw detection, sizing, data acquisition/storage, advanced signal processing, reports, documentation and software based diagnostics

  9. A broad band X-ray imaging spectrophotometer for astrophysical studies

    Science.gov (United States)

    Lum, Kenneth S. K.; Lee, Dong Hwan; Ku, William H.-M.

    1988-01-01

    A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

  10. Microelectrode-assisted low-voltage atmospheric pressure glow discharge in air

    Science.gov (United States)

    Liu, Wenzheng; Zhao, Shuai; Niu, Jiangqi; Chai, Maolin

    2017-09-01

    During the process of discharge, appropriately changing the paths corresponding to electric field lines and the field strength distribution along these paths, as well as increasing the number of initial electrons, can effectively enhance the uniformity of discharge and inhibit the formation of filamentary discharge. A method is proposed that uses a microelectrode to initiate the macroscopic discharge phenomenon. An asymmetric structure was designed comprising a single electrode of carbon fiber; this electrode structure is of helical-contact type. Benefitting from the special electric field distribution and the microdischarge process, a three-dimensional atmospheric pressure glow discharge was achieved in air, characterized by low discharge voltage, low energy consumption, good diffusion performance, and less ozone generation. The plasma studied is uniform and stable with good diffusion characteristics and low levels of contaminants and hence has potential applications in the field of air purification.

  11. Pressure-induced structural change from hexagonal to fcc metal lattice in scandium trihydride

    International Nuclear Information System (INIS)

    Ohmura, A.; Machida, A.; Watanuki, T.; Aoki, K.; Nakano, S.; Takemura, K.

    2007-01-01

    We synthesized scandium hydrides by hydrogenation of a scandium foil with hydrogen fluid under high pressure at ambient temperature. Scandium dihydride (ScH 2 ) and trihydride (ScH 3 ) were prepared near 4 and 5 GPa, respectively. The hydrogenation process and pressure-induced structural changes in ScH 3 were investigated by synchrotron radiation X-ray diffraction measurements up to 54.7 GPa. A structural transition from hexagonal to the fcc lattice began at 30 GPa and was completed at 46 GPa via an intermediate state similar to those reported for other hexagonal trihydrides. The intermediate state was not interpreted in terms of a coexisting state for the low-pressure hexagonal and the high-pressure fcc structures. The onset transition pressure of ScH 3 supported the previously proposed relation that the hexagonal-fcc transition pressure is inversely proportional to the ionic radius of the trihydride

  12. Thermal Stress Analysis for Ceramics Stalk in the Low Pressure Die Casting Machine

    Science.gov (United States)

    Noda, Nao-Aki; Hendra, Nao-Aki; Takase, Yasushi; Li, Wenbin

    Low pressure die casting (LPDC) is defined as a net shape casting technology in which the molten metal is injected at high speeds and pressure into a metallic die. The LPDC process is playing an increasingly important role in the foundry industry as a low-cost and high-efficiency precision forming technique. The LPDC process is that the permanent die and filling systems are placed over the furnace containing the molten alloy. The filling of the cavity is obtained by forcing the molten metal by means of a pressurized gas in order to rise into a ceramic tube, which connects the die to the furnace. The ceramics tube called stalk has high temperature resistance and high corrosion resistance. However, attention should be paid to the thermal stress when the stalk is dipped into the molten aluminum. It is important to develop the design of the stalk to reduce the risk of fracture because of low fracture toughness of ceramics. In this paper, therefore, the finite element method is applied to calculate the thermal stresses when the stalk is dipped into the crucible by varying the dipping speeds and dipping directions. It is found that the thermal stress can be reduced by dipping slowly if the stalk is dipped into the crucible vertically, while the thermal stress can be reduced by dipping fast if it is dipped horizontally.

  13. Experimental and modelling investigations of a dielectric barrier discharge in low-pressure argon

    International Nuclear Information System (INIS)

    Wagenaars, E; Brandenburg, R; Brok, W J M; Bowden, M D; Wagner, H-E

    2006-01-01

    The discharge behaviour of a dielectric barrier discharge (DBD) in low-pressure argon gas was investigated by experiments and modelling. The electrical characteristics and light emission dynamics of the discharge were measured and compared with the results of a two-dimensional fluid model. Our investigations showed that the discharge consisted of a single, diffuse discharge per voltage half-cycle. The breakdown phase of the low-pressure DBD (LPDBD) was investigated to be similar to the ignition phase of a low-pressure glow discharge without dielectrics, described by Townsend breakdown theory. The stable discharge phase of the LPDBD also showed a plasma structure with features similar to those of a classical glow discharge. The presence of the dielectric in the discharge gap led to the discharge quenching and thus the decay of the plasma. Additionally, the argon metastable density was monitored by measuring light emission from nitrogen impurities. A metastable density of about 5 x 10 17 m -3 was present during the entire voltage cycle, with only a small (∼10%) increase during the discharge. Finally, a reduction of the applied voltage to the minimum required to sustain the discharge led to a further reduction of the role of the dielectric. The discharge was no longer quenched by the dielectrics only but also by a reduction of the applied voltage

  14. Effect of mining thickness on abutment pressure of working face

    Energy Technology Data Exchange (ETDEWEB)

    Xie Guang-xiang; Wang Lei [Anhui University of Science and Technology, Huainan (China). Academy of Energy Sources and Security

    2008-04-15

    The distribution of the abutment pressure on the advancing front and on side of the working face was analyzed. Results show that the distribution of abutment pressure correlates with the thickness of the coal seam. The size of the abutment pressure peak is inversely proportional to the first mining thickness and the distance between peak and working face is proportional to the first mining thickness; that is to say the peak intensity falls as soon as the distribution range spreads. The distribution of side abutment pressure correlates somewhat with time. 6 refs.

  15. Proportionality for Military Leaders

    National Research Council Canada - National Science Library

    Brown, Gary D

    2000-01-01

    .... Especially lacking is a realization that there are four distinct types of proportionality. In determining whether a particular resort to war is just, national leaders must consider the proportionality of the conflict (i.e...

  16. Sensitive rapid analysis of iodine-labelled protein mixture on flat substrates with high spatial resolution

    International Nuclear Information System (INIS)

    Zanevskij, Yu.V.; Ivanov, A.B.; Movchan, S.A.; Peshekhonov, V.D.; Chan Dyk Tkhan'; Chernenko, S.P.; Kaminir, L.B.; Krejndlin, Eh.Ya.; Chernyj, A.A.

    1983-01-01

    Usability of rapid analysis by electrophoresis of the admixture of I 125 -labelled proteins on flat samples by means of URAN type installation developed using a multiwire proportional chamber is studied. The sensitivity of the method is better than 200 cpm/cm 2 and the spatial resolution is approximately 1 mm. The procedure of the rapid analysis is no longer than several tens of minutes

  17. Mobilities of slow electrons in low- and high-pressure gases and liquids

    International Nuclear Information System (INIS)

    Christophorou, L.G.

    1975-01-01

    Mobilities of slow (thermal and epithermal) electrons in low- (less than or approximately 500 Torr) and high- (approximately 500 to approximately 34,111 Torr) pressure gases are discussed and are related to the molecular structure and to the mobilities of thermal electrons in liquid media

  18. Critical heat flux in vertical flows at low pressures; Flux de chaleur critique en ecoulements verticaux aux pressions faibles

    Energy Technology Data Exchange (ETDEWEB)

    Olekhnowitch, A [Ecole Polytechnique, Montreal, PQ (Canada)

    1994-12-31

    This paper presents some critical heat flux (CHF) data obtained for vertical upflow of water in an 8 mm test section, for exit pressures ranging from 5 to 30 bar. The experiments were carried out for heated lengths of 0.75, 1, 1.4 and 1.8 m. In general, the collected data show trends similar to those described in the open literature. However, it was observed that for low pressures CHF depends on the heated length; this dependence begins to disappear for exit pressure of about 30 bar. The data have been compared with a look-up table and predictions of well known correlations. For low pressures and low mass fluxes, the look-up table seems to give better predictions, but for medium pressures and mass fluxes, the correlations perform better. 19 refs., 5 figs.

  19. Downflow film boiling in a rod bundle at low pressure

    International Nuclear Information System (INIS)

    Hochreiter, L.E.; Rosal, E.R.; Fayfich, R.R.

    1978-01-01

    A series of low pressure downflow film boiling heat transfer experiments were conducted in a 14-foot (4.27 m) long electrically heater rod bundle containing 336 heater rods. The resulting data was compared with the Dougall-Rohsenow dispersed flow film boiling correlation. The data was found to lie below this correlation as the quality was increased. It is believed that buoyancy effects decreased the heat transfer in downflow film boiling. (author)

  20. Double streamer phenomena in atmospheric pressure low frequency corona plasma

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Jung, H.; Gweon, B.; Choe, Wonho

    2010-01-01

    Time-resolved images of an atmospheric pressure corona discharge, generated at 50 kHz in a single pin electrode source, show unique positive and negative corona discharge features: a streamer for the positive period and a glow for the negative period. However, unlike in previous reports of dc pulse and low frequency corona discharges, multistreamers were observed at the initial time stage of the positive corona. A possible physical mechanism for the multistreamers is suggested.