WorldWideScience

Sample records for low-pressure hg lamp

  1. Hg+ ion density in low-pressure Ar-Hg discharge plasma used for liquid crystal display back-lighting

    International Nuclear Information System (INIS)

    Goto, Miki; Arai, Toshihiko

    1995-01-01

    The positive column of a low-pressure Ar-Hg discharge has been applied as a fluorescent light source for illumination. Many studies on the diagnostics and fundamental mechanisms have been carried out on both the classical fluorescent lamp (d=36 mm) and the compact fluorescent lamp (d=12 mm). On the other hand, a lamp of extremely narrow diameter (usually below 6 mm) has been recently developed for liquid crystal display (LCD) back-lighting and its importance is undoubtedly increasing. Some characteristics or mechanisms of the narrow-diameter lamp may be similar to those of the 36 mm one; however the similarity rule does not hold between them due to the contributions from a stepwise ionization process. Therefore, in order to clarify the excitation mechanism in the narrow-diameter lamp quantitatively, various parameters must be measured directly and some analysis must be done. The Hg + ion density and electron density are important parameters for the purpose of clarifying the excitation mechanism quantitatively. In this work, we have measured the Hg + ion density using the modified absorption method, and the electron density using the probe method in the Ar-Hg discharge of the 4 mm bore tube on bath temperature. Moreover, with combining the modified absorption method and the probe method, the Hg 2 + molecular ion density has been determined

  2. A study of capillary discharge lamps in Ar-Hg and Xe-Hg mixtures

    International Nuclear Information System (INIS)

    Denisova, N; Gavare, Z; Revalde, G; Skudra, Ja; Veilande, R

    2011-01-01

    Low-pressure capillary discharge lamps in Ar-Hg and Xe-Hg mixtures are studied. The discharge size is 0.5 mm (500 μm) in radius. According to the literature, such types of plasma sources are classified as microplasmas. The studies include spectrally resolved optical measurements, tomographic reconstructions and numerical simulations using the collisional-radiative model for an Ar-Hg plasma. We discuss the problems of theoretical modelling and experimental diagnostics of microplasma sources. It is shown that the conventional collisional-radiative model, based on the assumption that transportation of atoms in the highly excited states can be neglected, has limitations in modelling a capillary discharge in an Ar-Hg mixture. It is found that diffusion of highly excited mercury atoms to the wall influences the emission properties of the capillary discharge. We have concluded that applications of the emission tomography method to microplasmas require a special analysis in each particular case.

  3. Enhanced escape rate for Hg 254 nm resonance radiation in fluorescent lamps

    International Nuclear Information System (INIS)

    Lawler, James E; Raizen, Mark G

    2013-01-01

    The potential of the low-cost MAGIS isotopic separation method to improve fluorescent lamp efficacy is explored using resonance radiation transport simulations. New Hg isotopic mixes are discovered that yield escape rates for 254 nm Hg I resonance radiation equal to 117% to 122% of the rate for a natural isotopic mix under the same lamp conditions. (paper)

  4. Thomson scattering on a low-pressure, inductively-coupled gas discharge lamp

    International Nuclear Information System (INIS)

    Sande, M.J. van de; Mullen, J.J.A.M. van der

    2002-01-01

    Excitation and light production processes in gas discharge lamps are the result of inelastic collisions between atoms and free electrons in the plasma. Therefore, knowledge of the electron density n e and temperature T e is essential for a proper understanding of such plasmas. In this paper, an experimental system for laser Thomson scattering on a low-pressure, inductively-coupled gas discharge lamp and measurements of n e and T e in this lamp are presented. The experimental system is suitable for low electron temperatures (down to below 0.2 eV) and employs a triple grating spectrograph for a high stray light rejection, or equivalently a low stray light redistribution (R eff approximately 7x10 -9 nm -1 at 0.5 nm from the laser wavelength). The electron density detection limit of the system is n e approximately 10 16 m -3 . The modifications to the lamp that were necessary for the measurements are described, and results are presented and compared to previous work and trends expected from the electron particle and energy balances. The electron density and temperature are about n e approximately 10 19 m -3 and T e approximately 1 eV in the most active part of the plasma; the exact values depend on the argon filling pressure, the mercury pressure and the position in the lamp. (author)

  5. Low pressure arc discharge lamp apparatus with magnetic field generating means

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Maya, Jakob

    1987-01-01

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25.degree. C.

  6. Low pressure arc discharge lamp apparatus with magnetic field generating means

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1987-10-06

    A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

  7. Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg196 enrichment

    International Nuclear Information System (INIS)

    Grossman, M.W.

    1993-01-01

    The present invention is directed to a method of eliminating the cold spot zones presently used on Hg 196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment

  8. Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps

    International Nuclear Information System (INIS)

    Vasilyak, L. M.; Vasiliev, A. I.; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu.; Kudryavtsev, N. N.

    2011-01-01

    For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

  9. Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps

    Energy Technology Data Exchange (ETDEWEB)

    Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

    2011-12-15

    For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

  10. Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment

    Science.gov (United States)

    Grossman, Mark W.

    1993-01-01

    The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

  11. Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment

    Science.gov (United States)

    Grossman, M.W.

    1993-02-16

    The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

  12. Space-time electrostatic probing of low-pressure discharge lamps during the early stages of electrical breakdown

    NARCIS (Netherlands)

    Gendre, M.F.; Bowden, M.D.; Haverlag, M.; Nieuwenhuizen, van den H.C.M.; Gielen, J.W.A.M.; Kroesen, G.M.W.

    2005-01-01

    The lime and space evolution of the electrostatic potential of a low-pressure lamp is investigated during ignition with a special capacitive probe. Observations show that ionisation waves propagate back and forth in the lamp, coinciding with the displacement of a local region of strong potential

  13. Resonance broadening of Hg lines as a density diagnostic in high intensity discharge lamps

    International Nuclear Information System (INIS)

    Lawler, J E

    2004-01-01

    The use of width measurements on resonance broadened lines of Hg as a density diagnostic in high intensity discharge (HID) lamps is reviewed and further developed in this paper. Optical depths of Hg I lines at 491.6 nm, 577.0 nm, and 1014 nm are computed as a function of temperature to confirm that these lines are optically thin in most HID lamps. The effect of quadratic and quartic radial temperature variation on the width of resonance broadened lines is computed for arc core temperatures from 4000 K to 7000 K. Such variations in temperature, and inverse variations in Hg density, are found to increase the line widths by less than 10% for 'side-on' emission measurements averaged over the arc radius. Theoretical profiles of resonance broadened spectral lines, both radially averaged and as a function of chord offset, are presented. Observations of resonance broadened lines in a metal-halide HID lamp are presented and analysed. It is concluded that the widths of resonance broadened lines provide a convenient and reliable diagnostic for the arc core Hg density but are generally not very sensitive to the radial temperature and Hg density gradient

  14. Direct electron-impact mechanism of excitation of mercury monobromide in a double-pulse dielectric-barrier-discharge HgBr lamp

    Science.gov (United States)

    Datsyuk, V. V.; Izmailov, I. A.; Naumov, V. V.; Kochelap, V. A.

    2016-08-01

    In a nonequlibrium plasma of a gas-discharge HgBr lamp, the terminal electronic state of the HgBr(B-X) radiative transition with a peak wavelength of 502 nm remains populated for a relatively long time and is repeatedly excited to the B state in collisions with plasma electrons. This transfer of the HgBr molecules from the ground state X to the excited state B is the main mechanism of formation of the light-emitting molecules especially when the lamp is excited by double current pulses. According to our simulations, due to the electron-induced transitions between HgBr(X) and HgBr(B), the output characteristics of the DBD lamp operating in a double-pulse regime are better than those of the lamp operating in a single-pulse regime. In the considered case, the peak power is calculated to increase by a factor of about 2 and the lamp efficiency increases by about 50%.

  15. A study of the convective flow as a function of external parameters in a high-pressure metal halide discharge lamp (HgDyI3)

    Science.gov (United States)

    Hajji, S.; HadjSalah, S.; Benhalima, A.; Charrada, K.; Zissis, G.

    2016-06-01

    This paper deals with the modelling of the convection processes in metal-halide lamp discharges (HgDyI3). For this, we realized a 3D model, a steady, direct current powered and time-depending model for the solution of conservation equations relative to mass, momentum, and energy. After validation, this model was applied to the study of the effect of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp. Indeed, the electric current, the atomic ratio (Hg/Dy), and the effect of the convective transport have been studied.

  16. X-ray absorption imaging of Hg vapour in a ceramic metal-halide lamp using synchrotron radiation

    International Nuclear Information System (INIS)

    Curry, J J; Adler, H G; MacPhee, A; Narayanan, S; Wang, J

    2004-01-01

    The diagnostic technique of x-ray absorption imaging of Hg vapour in high-intensity discharge lamps has been extended. X-ray absorption imaging has been used previously to determine the time-averaged absolute Hg density (Curry J J, Sakai M and Lawler J E 1998 J. Appl. Phys. 84 3066). Now, using an intensified charge-coupled device detector and synchrotron radiation, time-resolved measurements have been made. Although no significant time-dependence was seen as a function of the electrical phase for an electronically ballasted lamp, real-time observations were made of the decaying Hg density during the cool-down period. The cold-spot temperature in a 150 W ceramic lamp containing Hg and rare-earth iodides decreased with a time constant of 48.4 s following arc extinction. The primary limitation to the sensitivity of these measurements has been identified, and methods for overcoming this limitation in future work are proposed. Other aspects of the technique are also discussed

  17. A study of the convective flow as a function of external parameters in a high-pressure metal halide discharge lamp (HgDyI{sub 3})

    Energy Technology Data Exchange (ETDEWEB)

    Hajji, S.; HadjSalah, S.; Benhalima, A.; Charrada, K. [Unité d' Etude des Milieux Ionisés et Réactifs, IPEIM, 5019 route de Kairouan Monastir, Université de Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d' Énergie, 118 rte Narbonne, Bât3R2, 31062 Toulouse (France)

    2016-06-15

    This paper deals with the modelling of the convection processes in metal–halide lamp discharges (HgDyI{sub 3}). For this, we realized a 3D model, a steady, direct current powered and time-depending model for the solution of conservation equations relative to mass, momentum, and energy. After validation, this model was applied to the study of the effect of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp. Indeed, the electric current, the atomic ratio (Hg/Dy), and the effect of the convective transport have been studied.

  18. Application of an antenna excited high pressure microwave discharge to compact discharge lamps

    International Nuclear Information System (INIS)

    Kando, M; Fukaya, T; Ohishi, Y; Mizojiri, T; Morimoto, Y; Shido, M; Serita, T

    2008-01-01

    A novel type of high pressure microwave discharge has been investigated to feed the microwave power at the centre of the compact high pressure discharge lamps using the antenna effect. This method of microwave discharge is named as the antenna excited microwave discharge (AEMD). The 2.45 GHz microwave of around 50 W from the solid state microwave generator can sustain a stable plasma column in the small gap between a couple of antennas fitted on the compact lamp filled with discharge gases at a pressure higher than atmosphere. The AEMD has been applied to a compact metal halide lamp and an extremely high pressure mercury discharge lamp. As a result, the metal halide lamp showed high luminous efficacy of around 130 lm W -1 . The excellent lamp properties obtained here can be explained by the low heating loss at the antennas and the lamp wall. The profiles of the microwave electric field in the lamp and the microwave launcher have been numerically calculated to consider the microwave power supply into the lamp

  19. Microwave discharge electrodeless lamps (MDEL). V. Microwave-assisted photolytic disinfection of Bacillus subtilis in simulated electroplating wash wastewaters.

    Science.gov (United States)

    Horikoshi, Satoshi; Tsuchida, Akihiro; Abe, Masahiko; Ohba, Naoki; Uchida, Masayoshi; Serpone, Nick

    2010-01-01

    This short article examines the microwave-assisted photolytic disinfection of aqueous solutions contaminated by Bacillus subtilis microorganisms using UV and vacuum-UV radiation emitted from a microwave discharge electrodeless lamp (MDEL), a device containing a Hg/Ar gas-fill that was proposed recently for use in Advanced Oxidation Processes (AOPs). Results of the disinfection are compared with those obtained from UV radiation emitted by a low-pressure electrode Hg lamp and by an excimer lamp. Also examined is the disinfection of B. subtilis aqueous media that contained Au3+ or Ni2+ ions, species often found in the treatment of electroplating wash wastewaters.

  20. Microwave discharge electrodeless lamps (MDEL). Part VII. Photo-isomerization of trans-urocanic acid in aqueous media driven by UV light from a novel Hg-free Dewar-like microwave discharge thermally-insulated electrodeless lamp (MDTIEL). Performance evaluation.

    Science.gov (United States)

    Horikoshi, Satoshi; Sato, Tatsuro; Sakamoto, Kazutami; Abe, Masahiko; Serpone, Nick

    2011-07-01

    A novel mercury-free Dewar-like (double-walled structure) microwave discharge thermally-insulated electrodeless lamp (MDTIEL) was fabricated and its performance evaluated using the photo-isomerization of trans-urocanic acid (trans-UA) in aqueous media as a test process driven by the emitted UV light when ignited with microwave radiation. The photo-isomerization processes trans-UA → cis-UA and cis-UA → trans-UA were re-visited using light emitted from a conventional high-pressure Hg light source and examined for the influence of UV light irradiance and solution temperature; the temperature dependence of the trans → cis process displayed a negative activation energy, E(a) = -1.3 cal mol(-1). To control the photo-isomerization of urocanic acid from the heat usually dissipated by a microwave discharge electrodeless lamp (single-walled MDEL), it was necessary to suppress the microwave-initiated heat. For comparison, the gas-fill in the MDEL lamp, which typically consists of a mixture of Hg and Ar, was changed to the more eco-friendly N(2) gas in the novel MDTIEL device. The dynamics of the photo-isomerization of urocanic acid driven by the UV wavelengths of the N(2)-MDTIEL light source were compared to those from the more conventional single-walled N(2)-MDEL and Hg/Ar-MDEL light sources, and with those from the Hg lamp used to irradiate, via a fiber optic, the photoreactor located in the wave-guide of the microwave apparatus. The heating efficiency of a solution with the double-walled N(2)-MDTIEL was compared to the efficiency from the single-walled N(2)-MDEL device. Advantages of N(2)-MDTIEL are described from a comparison of the dynamics of the trans-UA → cis-UA process on the basis of unit surface area of the lamp and unit power consumption. The considerably lower temperature on the external surface of the N(2)-MDTIEL light source should make it attractive in carrying out photochemical reactions that may be heat-sensitive such as the photothermochromic

  1. Reduced phenylalanine ammonia-lyase and tyrosine ammonia-lyase activities and lignin synthesis in wheat grown under low pressure sodium lamps

    Science.gov (United States)

    Guerra, D.; Anderson, A. J.; Salisbury, F. B.

    1985-01-01

    Wheat (Triticum aestivum L. cv Fremont) grown in hydroponic culture under 24-hour continuous irradiation at 560 to 580 micromoles per square meter per second from either metalhalide (MH), high pressure sodium (HPS), or low pressure sodium (LPS) lamps reached maturity in 70 days. Grain yields were similar under all three lamps, although LPS-grown plants lodged at maturity. Phenylalanine ammonia-lyase (PAL) and a tyrosine ammonia lyase (TAL) with lesser activity were detected in all extracts of leaf, inflorescence, and stem. Ammonia-lyase activities increased with age of the plant, and plants grown under the LPS lamp displayed PAL and TAL activities lower than wheat cultured under MH and HPS radiation. Greenhouse solar-grown wheat had the highest PAL and TAL activities. Lignin content of LPS-grown wheat was also significantly reduced from that of plants grown under MH or HPS lamps or in the greenhouse, showing a correlation with the reduced PAL and TAL activities. Ratios of far red-absorbing phytochrome to total phytochrome were similar for all three lamps, but the data do not yet warrant a conclusion about specific wavelengths missing from the LPS lamps that might have induced PAL and TAL activities in plants under the other lamps.

  2. Selective gettering of hydrogen in high pressure metal iodide lamps

    International Nuclear Information System (INIS)

    Kuus, G.

    1976-01-01

    One of the main problems in the manufacture of high pressure gas discharge lamps is the elimination of gaseous impurities from their arc tubes. Long degassing processes of all the lamp components are necessary in order to produce lamps with a low ignition voltage and good maintenance of the radiation properties. The investigation described deals with a selective getter place in the arc tube which can replace the long degassing process. The getter consists of a piece of yttrium encapsulated in thin tantalum foil. By this way it is possible to use the gettering action of tantalum and yttrium without having reaction between the metal iodide of the arc tube and yttrium. Yttrium is used because this metal can adsorb a large quantity of hydrogen even at a temperature of 1000 0 C. Hydrogen forms the main gaseous impurity in the high pressure metal iodide lamp. For this reason the adsorption properties like adsorption rate and capacity of the tantalum--yttrium getter for hydrogen are examined, and the results obtained from lamp experiments are given

  3. Characterization and modelling of low-pressure rf discharges at 2-500 MHz for miniature alkali vapour dielectric barrier discharge lamps

    International Nuclear Information System (INIS)

    Venkatraman, Vinu; Shea, Herbert; Pétremand, Yves; Rooij, Nico de

    2012-01-01

    Low-pressure dielectric barrier discharge (DBD) alkali vapour lamps are of particular interest for portable atomic clocks because they (1) could enable low-power operation, (2) generate the precise required wavelength, (3) are planar simplifying chip-level integration and (4) use external electrodes, which increases the lifetime. Given the stringent requirements on lamps for atomic clocks, it is important to identify the parameters that can be optimized to meet these performance requirements (size, power consumption, stability, reliability). We report on the electrical and optical characteristics of dielectric barrier plasma discharges observed in two configurations: (1) in a vacuum chamber over a wide low-pressure range (2-100 mbar) for three different buffer gases (He, Ar, N 2 ) driven at different frequencies between 2 and 500 MHz and (2) on microfabricated hermetically sealed Rb vapour cells filled with 30 and 70 mbar of Ar. We discuss the optimum conditions for a low-power and stable operation of a Rb vapour DBD lamp, aimed at chip-scale atomic clocks. We also present the electrical modelling of the discharge parameters to understand the power distribution mechanisms and the input power to discharge power coupling efficiency.

  4. Note: Simple means for selective removal of the 365 nm line from the Hg spectrum using Dy

    DEFF Research Database (Denmark)

    Vesborg, Peter Christian Kjærgaard; Chorkendorff, Ib; Brock-Nannestad, T.

    2011-01-01

    is cheap, robust, and stable towards degradation or bleaching - even under intense irradiation. The absorption spectrum for the Dy-filter is presented along with emission spectra from both low-pressure and high-pressure Hg-lamps to illustrate the utility of the technique under best-case and worst...

  5. Power supply improvements for ballasts-low pressure mercury/argon discharge lamp for water purification

    Science.gov (United States)

    Bokhtache, A. Aissa; Zegaoui, A.; Djahbar, A.; Allouache, H.; Hemici, K.; Kessaissia, F. Z.; Bouchrit, M. S.; Aillerie, M.

    2017-02-01

    The low-pressure electrical discharges established in the mercury rare gas mixtures are the basis of many applications both in the field of lighting and for industrial applications. In order to select an efficient high frequency power supply (ECG -based PWM inverter), we present and discuss results obtained in the simulation of three kinds of power supplies delivering a 0.65 A - 50KHz sinusoidal current dedicated to power low pressure UV Mercury - Argon lamp used for effect germicide on water treatment thus allowing maximum UVC radiation at 253.7 nm. Three ballasts half-bridge configurations were compared with criteria based on resulting germicide efficiency, electrical yield and reliability, for example the quality of the sinusoidal current with reduced THD, and finally, we also considered in this analysis the final economic aspect.

  6. Recycling of rare earths from Hg-containing fluorescent lamp scraps by solid state chlorination

    International Nuclear Information System (INIS)

    Lorenz, Tom; Froehlich, Peter; Bertau, Martin; Golon, Katja

    2015-01-01

    Solid state chlorination with NH 4 Cl comprises a method for rare earth recycling apart from pyro- or hydrometallurgical strategies. The examined partially Hg-containing fluorescent lamp scraps are rich in rare earths like La, Ce, Tb and Gd, but especially in Y and Eu. By mixing with NH 4 Cl and heating up to NH 4 Cl decomposition temperature in a sublimation reactor, Y and Eu could be transferred selectively into their respective metal chlorides with high yields. The yield and selectivity depend on temperature and the ratio of NH 4 Cl to fluorescent lamp scraps, which were varied systematically.

  7. Pulsed operation of high-pressure-sodium discharge lamps

    International Nuclear Information System (INIS)

    Guenther, K.; Kloss, H.G.; Lehmann, T.; Radtke, R.; Serick, F.

    1990-01-01

    Results of spectral and photometric measurements are presented for pulsed operated high-pressure-sodium lamps. Choosing for the colour temperature a value of 3000 K, the output spectrum was optimized with respect to colour rendition and lamp efficacy taking the pulse parameters, the sodium mole fraction, and the cold spot temperature as quantities to be varied. For the nominal rating of 70 W a maximum lamp efficacy of 70 lm/W and a colour rendering index of 40 can be obtained. Further improvements of the colour rendition require an enhanced sodium vapour pressure which can be achieved by operating the lamp at rised cold spot temperature. (orig.)

  8. Pulsed operation of high-pressure-sodium discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, K; Kloss, H G; Lehmann, T [Zentrum fuer Forschung und Technologie, Berlin (Germany, F.R.); Radtke, R; Serick, F [Zentralinstitut fuer Elektronenphysik, Berlin (Germany, F.R.)

    1990-01-01

    Results of spectral and photometric measurements are presented for pulsed operated high-pressure-sodium lamps. Choosing for the colour temperature a value of 3000 K, the output spectrum was optimized with respect to colour rendition and lamp efficacy taking the pulse parameters, the sodium mole fraction, and the cold spot temperature as quantities to be varied. For the nominal rating of 70 W a maximum lamp efficacy of 70 lm/W and a colour rendering index of 40 can be obtained. Further improvements of the colour rendition require an enhanced sodium vapour pressure which can be achieved by operating the lamp at rised cold spot temperature. (orig.).

  9. Mercury-free electrodeless discharge lamp: effect of xenon pressure and plasma parameters on luminance

    International Nuclear Information System (INIS)

    Nazri Dagang Ahmad; Kondo, Akira; Motomura, Hideki; Jinno, Masafumi

    2009-01-01

    Since there is much concern about environmental preservation, the authors have paid attention to the uses of mercury in lighting application. They have focused on the application of the xenon low-pressure inductively coupled plasma (ICP) discharge in developing cylindrical type mercury-free light sources. ICP can be operated at low filling gas pressures and demonstrates significant potential in producing high density plasma. Xenon pressure was varied from 0.1 to 100 Torr and the lamp luminance was measured. The gas pressure dependence shows an increase in luminance at pressures below 1 Torr. In order to clarify this behaviour, measurement of plasma parameters was carried out using the double probe method and its relation to lamp luminance is discussed. As the gas pressure is decreased (from 1 to 0.01 Torr), the electron temperature increases while the electron density decreases while at the same time the lamp luminance increases. There are several factors that are believed to contribute to the increase in luminance in the very low pressure region. Increases in luminance are considered to be due to the electron-ion recombination process which brings a strong recombination radiation in continuum in the visible region and also due to the effect of stochastic heating.

  10. High-pressure sodium lamp

    NARCIS (Netherlands)

    1996-01-01

    A high pressure sodium lamp of the invention is provided with a discharge vessel (20) which is enclosed with intervening space (1) by an outer bulb (10), which space contains a gas-fill with at least 70 mol. % nitrogen gas. Electrodes (30a, 30b) are positioned in the discharge vessel (20) and are

  11. Optical emission spectroscopy of metal-halide lamps: Radially resolved atomic state distribution functions of Dy and Hg

    NARCIS (Netherlands)

    Nimalasuriya, T.; Flikweert, A.J.; Stoffels, W.W.; Haverlag, M.; Mullen, van der J.J.A.M.; Pupat, N.B.M.

    2006-01-01

    Absolute line intensity measurements are performed on a metal-halide lamp. Several transitions of atomic and ionic Dy and atomic Hg are measured at different radial positions from which we obtain absolute atomic and ionic Dy intensity profiles. From these profiles we construct the radially resolved

  12. Modelling the Dynamic Interaction Power System Lamp - Application to High Pressure Mercury Gas Discharge Lamps

    Directory of Open Access Journals (Sweden)

    ZIANE, M.

    2007-11-01

    Full Text Available The aim of this paper is to study the dynamic behaviour of a plant constituted by an electrical power system and a gas discharge lamp, this latter, increasingly used in street lighting, remains a nonlinear load element. Various approaches are used to represent it, one is the approximation of the discharge represented by a hot "channel", which verifies the assumption of local thermodynamic equilibrium [LTE] or the polynomial form of the conductance variation. A calculation procedure, based on "channel" approximation of the high pressure mercury (HPM gas-discharge lamp, is developed to determine the physical and electric magnitudes, which characterize the dynamic behavior of the couple "lamp-electrical power system". The evolution of the lamp properties when principal parameters of the discharge (pressure of mercury, voltage supply, frequency are varying were studied and analyzed. We show the concordance between simulation, calculations and measurements for electric, energetic or irradiative characteristics. The model reproduces well the evolution of properties of the supply when principal parameters of the discharge vary.

  13. The high pressure xenon lamp as a source of radiation

    International Nuclear Information System (INIS)

    Heerdt, J.A. ter.

    1979-01-01

    An account is given of an investigation into the radiation properties of a commercially available high pressure xenon lamp (type XBO 900 W) in the spectral range 0.3 to 3 μm. The purpose of the study was to find out whether such a lamp can serve as a (secondary) standard of radiation in spectroscopic and radiometric measurements. The main advantades of the xenon lamp over other secondary standards such as the tungsten strip lamp and the anode of a carbon arc lamp are the high temperature of its discharge and the resulting strong radiation over a broad spectral range. (Auth.)

  14. Preliminary Investigation of a Dielectric Barrier Discharge Lamp in Open Air at Atmospheric Pressure

    International Nuclear Information System (INIS)

    Liu Feng; Wang Wei-Wei; Chang Xi-Jiang; Liang Rong-Qing

    2011-01-01

    A dielectric barrier discharge (DBD) lamp is investigated by using sinusoidal power with a 10 kHz frequency in open air at atmospheric pressure. With increasing applied voltages, the different discharge phenomena appear. At relatively low voltages, the discharge states are general stochastic filamentary discharges with weak light. However, at relatively high voltages, the walls of quartz tubes are heated sharply by plasma, and then the dazzling light is emitted very quickly to form the DBD Lamp, corresponding to the low maintaining voltage that is lower than the ignited voltage. The discharge state or mode of the DBD lamp that corresponds to the glow discharge is deduced according to the wave form of the circuit current, which is evidently different from the filamentary discharges. Under these conditions, the spectrum of the DBD lamp is continuous in the range 400–932 nm, which is scanned in the range 300–932 nm. It is also shown that there is another discharge state or mode that is different from the traditional filamentary discharges. Therefore, it is concluded that the discharge state or mode of the DBD lamp is a glow discharge. (physics of gases, plasmas, and electric discharges)

  15. Structural and elastic properties of defect chalcopyrite HgGa{sub 2}S{sub 4} under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Gomis, O., E-mail: osgohi@fis.upv.es [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Santamaría-Pérez, D. [Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universitat de València, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 València (Spain); Departamento de Química Física I, Universidad Complutense de Madrid, MALTA Consolider Team, Avenida Complutense s/n, 28040 Madrid (Spain); Vilaplana, R.; Luna, R. [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Sans, J.A.; Manjón, F.J. [Instituto de Diseño para la Fabricación y Producción Automatizada, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Errandonea, D. [Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universitat de València, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 València (Spain); and others

    2014-01-15

    Highlights: • Single crystals of HgGa{sub 2}S{sub 4} with defect-chalcopyrite (DC) structure were synthesized. • High-pressure X-ray diffraction in DC-HgGa{sub 2}S{sub 4} was performed. • Equation of state of DC-HgGa{sub 2}S{sub 4} determined (bulk modulus of 48.4 GPa). • Calculated elastic constants of DC-HgGa{sub 2}S{sub 4} reported at different pressures. • DC-HgGa{sub 2}S{sub 4} becomes mechanically unstable above 13.8 GPa. -- Abstract: In this work, we focus on the study of the structural and elastic properties of mercury digallium sulfide (HgGa{sub 2}S{sub 4}) at high pressures. This compound belongs to the family of AB{sub 2}X{sub 4} ordered-vacancy compounds and exhibits a tetragonal defect chalcopyrite structure. X-ray diffraction measurements at room temperature have been performed under compression up to 15.1 GPa in a diamond anvil cell. Our measurements have been complemented and compared with ab initio total energy calculations. The axial compressibility and the equation of state of the low-pressure phase of HgGa{sub 2}S{sub 4} have been experimentally and theoretically determined and compared to other related ordered-vacancy compounds. The pressure dependence of the theoretical cation–anion and vacancy-anion distances and compressibilities in HgGa{sub 2}S{sub 4} are reported and discussed in comparison to other related ordered-vacancy compounds. Finally, the pressure dependence of the theoretical elastic constants and elastic moduli of HgGa{sub 2}S{sub 4} has been studied. Our calculations indicate that the low-pressure phase of HgGa{sub 2}S{sub 4} becomes mechanically unstable above 13.8 GPa.

  16. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    International Nuclear Information System (INIS)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-01-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×10 8 cm −2 s −1 to 10 14 cm −2 s −1 . The 202 Hg(n,γ) 203 Hg nuclear reaction was used for mercury mass evaluation. Activities of 203 Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg 2 Cl 2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps. - Highlights: • Mercury is an essential component of fluorescent lamps. • Fluorescent lamps were irradiated in neutron fields in research reactor. • 203 Hg induced radionuclide activity was measured using gamma spectrometry. • Mercury mass in fluorescent lamps can be measured by neutron activation analysis.

  17. The cataphoretic emitter effect exhibited in high intensity discharge lamp electrodes

    Science.gov (United States)

    Mentel, Juergen

    2018-01-01

    A mono-layer of atoms, electropositive with respect to the substrate atoms, forms a dipole layer, reducing its work function. Such a layer is generated by diffusion of emitter material from the interior of the substrate, by vapour deposition or by deposition of emitter material onto arc electrodes by cataphoresis. This cataphoretic emitter effect is investigated within metal halide lamps with transparent YAG ceramic burners, and within model lamps. Within the YAG lamps, arcs are operated with switched-dc current between rod shaped tungsten electrodes in high pressure Hg vapour seeded with metal iodides. Within the model lamps, dc arcs are operated between rod-shaped tungsten electrodes—one doped—in atmospheric pressure Ar. Electrode temperatures are determined by 1λ -pyrometry, combined with simulation of the electrode heat balance. Plasma temperatures, atom and ion densities of emitter material are determined by emission and absorption spectroscopy. Phase resolved measurements in YAG lamps seeded with CeI3, CsI, DyI3, TmI3 and LaI3 show, within the cathodic half period, a reduction of the electrode temperature and an enhanced metal ion density in front of the electrode, and an opposite behavior after phase reversal. With increasing operating frequency, the state of the cathode overlaps onto the anodic phase—except for Cs, being low in adsorption energy. Generally, the phase averaged electrode tip temperature is reduced by seeding a lamp with emitter material; its height depends on admixtures. Measurements at tungsten electrodes doped with ThO2, La2O3 and Ce2O3 within the model lamp show that evaporated emitter material is redeposited by an emitter ion current onto the electrode surface. It reduces the work function of tungsten cathodes above the evaporation temperature of the emitter material, too; and also of cold anodes, indicating a field reversal in front of them. The formation of an emitter spot at low cathode temperature and high emitter material

  18. Comparison of direct and alternating current vacuum ultraviolet lamps in atmospheric pressure photoionization.

    Science.gov (United States)

    Vaikkinen, Anu; Haapala, Markus; Kersten, Hendrik; Benter, Thorsten; Kostiainen, Risto; Kauppila, Tiina J

    2012-02-07

    A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production. © 2012 American Chemical Society

  19. Non-destructive measurement of Xe filling pressure in mercury-free metal halide lamp

    International Nuclear Information System (INIS)

    Motomura, Hideki; Enoki, Kyosuke; Jinno, Masafumi

    2010-01-01

    Mercury-free metal halide lamps (MHLs) for automotive purposes have been developing in the market. When mercury is not used, the electric and emission characteristics of the lamp strongly depend on the xenon filling pressure. Therefore a non-destructive gas pressure estimation technique is required to obtain stable performance of the lamps as commercial products. The authors have developed an estimation method by which the gas pressure is estimated from the current peak value at the initial stage of ignition under pulsed operation. It is shown that accuracy of the order of ±(0.1-0.3) atm is obtained using an empirical formula.

  20. Time resolved Thomson scattering measurements on a high pressure mercury lamp

    NARCIS (Netherlands)

    Vries, de N.; Zhu, Xiao-Yan; Kieft, E.R.; Mullen, van der J.J.A.M.

    2005-01-01

    Time resolved Thomson scattering (TS) measurements have been performed on an ac driven high pressure mercury lamp. For this high intensity discharge (HID) lamp, TS is coherent and a coherent fitting routine, including rotational Raman calibration, was used to determine ne and Te from the measured

  1. Fabry-Perot measurements of barium temperature in fluorescent lamps

    International Nuclear Information System (INIS)

    Hadrath, S; Garner, R

    2010-01-01

    A scanning Fabry-Perot interferometer (FPI) is used to determine the temperature of barium atoms that are liberated from the electrodes of fluorescent lamps during their steady-state operation. Barium, a constituent of the work function lowering emitter material that is placed on the tungsten coil that forms the electrode, is liberated primarily by evaporation from the hot (∼1300 K) thermionic electrode. However, there may be situations or modes of operation in which barium is, in addition, sputtered, a condition which may lead to increased end-darkening, shortened life and increased mercury consumption in the lamp. Using the FPI diagnostic, the occurrence of sputtering is inferred when barium temperatures are much greater than the electrode temperature. The FPI diagnostic senses resonance radiation (λ = 553 nm) emitted by barium atoms excited in the low pressure discharge environment, and infers temperature from the Doppler broadened linewidth. The diagnostic has proven to be successful in a number of situations. Measurements have been made on rare gas discharges and on Hg-argon discharges for different discharge currents, gas pressures and auxiliary coil currents. Measurements are phase resolved for ac-driven discharges.

  2. Time resolved Thomson scattering measurements on a high pressure mercury lamp

    International Nuclear Information System (INIS)

    Vries, N de; Zhu, X; Kieft, E R; Mullen, J van der

    2005-01-01

    Time resolved Thomson scattering (TS) measurements have been performed on an ac driven high pressure mercury lamp. For this high intensity discharge (HID) lamp, TS is coherent and a coherent fitting routine, including rotational Raman calibration, was used to determine n e and T e from the measured spectrum. The maximum electron density and electron temperature obtained in the centre of the discharge varied in a time period of 5 ms between 1 x 10 21 m -3 e 21 m -3 and 6500 K e < 7100 K. In order to test the non-intrusive character of TS, we have derived a general expression for the heating of the electrons. By applying this to our mercury lamp and laser settings, we have confirmed the non-intrusiveness of our method. This is supported by the experimental findings. Furthermore, because the TS results were obtained directly, thus, without the local thermodynamic equilibrium (LTE) assumptions, they enabled us to follow the deviations from LTE as a function of time. Contrary to the generally made assumption that HID lamps are in LTE, we have found deviations from both the thermal and chemical equilibrium inside the high pressure mercury lamp at different phases of the applied current

  3. Determination of line broadening constants in high pressure discharge lamps

    International Nuclear Information System (INIS)

    Weiss, M; Schubert, H; Meier, S; Born, M; Reiter, D; Stroesser, M

    2005-01-01

    A numerical model of the radiative transfer in high pressure metal halide discharge lamps is used to determine line broadening parameters for atomic scandium lines. The determined broadening constants are in qualitative agreement with theoretical estimates in many cases, but significant deviations exist. The data obtained from this paper can, therefore, be used to further improve modelling of radiative contributions to the energy balance in such types of discharge lamps

  4. Discharge lamp technologies

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, J. [GE Lighting, Cleveland, OH (United States)

    1994-12-31

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advance. A general overview of discharge lighting technology can be found in the book of Waymouth (1971). A recent review of low pressure lighting discharge science is found in Dakin (1991). The pioneering paper of Reiling (1964) provides a good introduction to metal halide discharges. Particularly relevant to lighting for plant growth, a recent and thorough treatment of high pressure Na lamps is found in the book by deGroot and vanVliet (1986). Broad practical aspects of lighting application are thoroughly covered in the IES Lighting Handbook edited by Kaufman (1984).

  5. Mercury mass measurement in fluorescent lamps via neutron activation analysis

    Science.gov (United States)

    Viererbl, L.; Vinš, M.; Lahodová, Z.; Fuksa, A.; Kučera, J.; Koleška, M.; Voljanskij, A.

    2015-11-01

    Mercury is an essential component of fluorescent lamps. Not all fluorescent lamps are recycled, resulting in contamination of the environment with toxic mercury, making measurement of the mercury mass used in fluorescent lamps important. Mercury mass measurement of lamps via instrumental neutron activation analysis (NAA) was tested under various conditions in the LVR-15 research reactor. Fluorescent lamps were irradiated in different positions in vertical irradiation channels and a horizontal channel in neutron fields with total fluence rates from 3×108 cm-2 s-1 to 1014 cm-2 s-1. The 202Hg(n,γ)203Hg nuclear reaction was used for mercury mass evaluation. Activities of 203Hg and others induced radionuclides were measured via gamma spectrometry with an HPGe detector at various times after irradiation. Standards containing an Hg2Cl2 compound were used to determine mercury mass. Problems arise from the presence of elements with a large effective cross section in luminescent material (europium, antimony and gadolinium) and glass (boron). The paper describes optimization of the NAA procedure in the LVR-15 research reactor with particular attention to influence of neutron self-absorption in fluorescent lamps.

  6. Bromate formation from the oxidation of bromide in the UV/chlorine process with low pressure and medium pressure UV lamps.

    Science.gov (United States)

    Fang, Jingyun; Zhao, Quan; Fan, Chihhao; Shang, Chii; Fu, Yun; Zhang, Xiangru

    2017-09-01

    When a bromide-containing water is treated by the ultraviolet (UV)/chlorine process, hydroxyl radicals (HO) and halogen radicals such as Cl or Br are formed due to the UV photolysis of free halogens. These reactive species may induce the formation of bromate, which is a probable human carcinogen. Bromate formation in the UV/chlorine process using low pressure (LP) and medium pressure (MP) lamps in the presence of bromide was investigated in the present study. The UV/chlorine process significantly enhanced bromate formation as compared to dark chlorination. The bromate formation was elevated with increasing UV fluence, bromide concentration, and pH values under both LP and MP UV irradiations. It was significantly enhanced at pH 9 compared to those at pH 6 and 7 with MP UV irradiation, while it was slightly enhanced at pH 9 with LP UV. The formation by UV/chlorine process started with the formation of free bromine (HOBr/OBr - ) through the reaction of chlorine and bromide, followed by a subsequent oxidation of free bromine and formation of BrO and bromate by reacting with radicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Physics of mercury-free high-pressure discharge lamps

    International Nuclear Information System (INIS)

    Born, M

    2002-01-01

    This paper gives a summary of recent results about the replacement of mercury in high-pressure discharge lamps by metallic zinc. Actually, this topic is of high relevance for the lighting industry due to the need of more environmentally friendly products. The work presented here is supported by the German government under contract no 13N8072 and 13N8264. Due to upcoming European legislations which are expected for the year 2003, the replacement of mercury in lighting products is a high priority task. For example, mercury-free headlight discharge lamps are requested by the automotive industry. Pure zinc/argon discharges as well as lamps including zinc or mercury and metal halide additives are investigated. Experimental data are compared with model calculations of the energy balance involving the transport of heat and radiation. Since the excitation energies of relevant zinc transitions are lower than for mercury, axis temperatures of pure zinc lamps are about 300 K below the value of mercury arcs. In addition, the thermal conductivity of zinc including the contribution of radiation diffusion is larger than compared to mercury. From lamp voltage measurements it is found that the cross section for elastical electron scattering by zinc atoms is about the same than for mercury. When adding metal halides to a pure zinc discharge with argon as a starting gas, i.e. NaI, TlI, DyI 3 , axis temperatures decrease to about 5100 K due to strong radiation cooling. In order to obtain sufficiently large lamp voltages, wall temperatures of more than 1300 K are adjusted by means of polycrystalline aluminaoxide (Al 2 O 3 ) as a wall material. Electric field strengths of 6.0 and 8.6 V mm -1 are measured for metal halide lamps containing zinc or mercury, respectively. The light technical data of the discharges are very close, since mercury and zinc do not contribute significantly to the radiation in the visible range. Efficacies of up to 93 and 100 lm W -1 are found in metal halide

  8. Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp

    International Nuclear Information System (INIS)

    Zalach, J.; Franke, St.; Schoepp, H.; Araoud, Z.; Charrada, K.; Zissis, G.

    2011-01-01

    Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-up of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.

  9. Generation of ion-acoustic waves in an inductively coupled, low-pressure discharge lamp

    International Nuclear Information System (INIS)

    Camparo, J. C.; Klimcak, C. M.

    2006-01-01

    For a number of years it has been known that the alkali rf-discharge lamps used in atomic clocks can exhibit large amplitude intensity oscillations. These oscillations arise from ion-acoustic plasma waves and have typically been associated with erratic clock behavior. Though large amplitude ion-acoustic plasma waves are clearly deleterious for atomic clock operation, it does not follow that small amplitude oscillations have no utility. Here, we demonstrate two easily implemented methods for generating small amplitude ion-acoustic plasma waves in alkali rf-discharge lamps. Furthermore, we demonstrate that the frequency of these waves is proportional to the square root of the rf power driving the lamp and therefore that their examination can provide an easily accessible parameter for monitoring and controlling the lamp's plasma conditions. This has important consequences for precise timekeeping, since the atomic ground-state hyperfine transition, which is the heart of the atomic clock signal, can be significantly perturbed by changes in the lamp's output via the ac-Stark shift

  10. Examining the effects of fill gas pressure on the distribution of copper atoms in a hollow cathode lamp

    International Nuclear Information System (INIS)

    Oliver, D.R.; Finlayson, T.R.

    1996-01-01

    A modified Copper Hollow Cathode lamp has been used to examine the effects of fill gas pressure on the distribution of sputtered Copper atoms in the body of the lamp. The lamp was modified by placing a quartz disc above the cathode, perpendicular to both the cathode bore and the cathode-anode axis. While the lamp is operating, some of the Copper that has been sputtered out of the cathode bore is deposited on the disc. Modified lamps have been operated at a variety of pressures, and the resulting deposition profiles recorded using an optical microscope. A summary of variations between different pressures are presented

  11. Recycling of rare earths from Hg-containing fluorescent lamp scraps by solid state chlorination; Rueckgewinnung Seltener Erden aus quecksilberbelasteten Leuchtstoffen mittels Feststoffchlorierung

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Tom; Froehlich, Peter; Bertau, Martin [TU Bergakademie Freiberg (Germany); Golon, Katja [FNE Entsorgungsdienste GmbH, Freiberg (Germany)

    2015-10-15

    Solid state chlorination with NH{sub 4}Cl comprises a method for rare earth recycling apart from pyro- or hydrometallurgical strategies. The examined partially Hg-containing fluorescent lamp scraps are rich in rare earths like La, Ce, Tb and Gd, but especially in Y and Eu. By mixing with NH{sub 4}Cl and heating up to NH{sub 4}Cl decomposition temperature in a sublimation reactor, Y and Eu could be transferred selectively into their respective metal chlorides with high yields. The yield and selectivity depend on temperature and the ratio of NH{sub 4}Cl to fluorescent lamp scraps, which were varied systematically.

  12. Study of the external parameters influence on the channel discharge radius in Hg lamps

    International Nuclear Information System (INIS)

    Cristea, M.

    2000-01-01

    In this paper, the plasma electric conductivity and the channel radius for high-pressure mercury arc discharge are calculated. The examined model emphasizes some correlations between various external parameters (current intensity, silicon tube diameter and working pressure) and the channel discharge radius. After model validation, the temperature distribution in the discharge zone is obtained and then the electrons and ions distribution, the electric carriers mobility and the electric conductivity for different lamp characteristics are calculated. The applied numerical simulation shows a linear increase of the channel radius with the tube radius Rw increasing, and a very week pressure dependence (in the range 0.5 - 5 atm.)

  13. Physical aspects of mercury-free high pressure discharge lamps

    International Nuclear Information System (INIS)

    Born, M.

    2002-01-01

    This paper gives a summary of recent results about the replacement of mercury in high pressure discharge lamps by metallic zinc. Actually, this topic is of high relevance for the lighting industry due to the need of more environmentally friendly products. The work presented here is supported by the German government under contract no. 13N8072. Pure zinc/argon discharges as well as lamps including zinc or mercury and metal halide additives are investigated. Experimental data are compared with model calculations of the energy balance involving the transport of heat and radiation. Since the excitation energies of relevant zinc transistions are lower than for mercury, axis temperatures of pure zinc lamps are about 300 K below the value of mercury arcs. In addition, the thermal conductivity of zinc including the contribution of radiation diffusion is larger than compared to mercury. From lamp voltage measurements it is found that the cross section for elastical electron scattering by zinc atoms is about the same as for mercury. When adding metal halides to a pure zinc discharge with argon as a starting gas, i.e. NaI, TlI, DyI3, axis temperatures decrease to about 5100 K due to strong radiation cooling. In order to obtain sufficiently large lamp voltages, wall temperatures of more than 1300 K are adjusted by means of polycrystalline aluminaoxide (Al2O3) as a wall material. Electrical field strenghts of 6.0 V/mm and 8.6 V/mm are measured for metal halide lamps containing zinc or mercury, respectively. The light technical data of the discharges are very close, since mercury and zinc do not contribute significantly to the radiation in the visible range. Efficacies of up to 93 lm/W and 100 lm/W are found in metal halide lamps with zinc and mercury, respectively. Consequently, zinc turns out to be an attractive replacer for mercury in this type of lamp not only from an environmental point of view

  14. X-ray induced fluorescence measurement of segregation in a DyI{sub 3}-Hg metal-halide lamp

    Energy Technology Data Exchange (ETDEWEB)

    Nimalasuriya, T [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Curry, J J [National Institute of Standards and Technology, 100 Bureau Drive, Stop 8422, Gaithersburg, MD 20899-8422 (United States); Sansonetti, C J [National Institute of Standards and Technology, 100 Bureau Drive, Stop 8422, Gaithersburg, MD 20899-8422 (United States); Ridderhof, E J [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Shastri, S D [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Flikweert, A J [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Stoffels, W W [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Haverlag, M [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Mullen, J J A M van der [Department of Applied Physics, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands)

    2007-05-07

    Segregation of elemental Dy in a DyI{sub 3}-Hg metal-halide high-intensity discharge lamp has been observed with x-ray induced fluorescence. Significant radial and axial Dy segregation are seen, with the axial segregation characterized by a Fischer parameter value of {lambda} = 0.215 {+-} 0.002 mm{sup -1}. This is within 7% of the value ({lambda} = 0.20 {+-} 0.01 mm{sup -1}) obtained by Flikweert et al (2005 J. Appl. Phys. 98 073301) based on laser absorption by neutral Dy atoms. Elemental I is seen to exhibit considerably less axial and radial segregation. Some aspects of the observed radial segregation are compatible with a simplified fluid picture describing two main transition regions in the radial coordinate. The first transition occurs in the region where DyI{sub 3} molecules are in equilibrium with neutral Dy atoms. The second transition occurs where neutral Dy atoms are in equilibrium with ionized Dy. These measurements are part of a larger study on segregation in metal-halide lamps under a variety of conditions.

  15. Phase-resolved response of a metal-halide lamp

    International Nuclear Information System (INIS)

    Flikweert, A J; Beks, M L; Nimalasuriya, T; Kroesen, G M W; Van der Mullen, J J A M; Stoffels, W W

    2009-01-01

    The metal-halide (MH) lamp sometimes shows unwanted colour segregation, caused by a combination of convection and diffusion. In the past we investigated the lamp, running on a switched dc ballast of 120 Hz, using a dc approximation for the distribution of the radiating species. Here we present phase-resolved intensity measurements to verify this approximation. The MH lamp contains Hg as buffer gas and DyI 3 as salt additive; we measure the light emitted by Dy and by Hg atoms. An intensity fluctuation of ∼25% close to the electrodes is found only. The observed fluctuations are explained by the cataphoresis effect and temperature fluctuations; the time scales are in the same order. Furthermore, measurements at higher gravity in a centrifuge (up to 10g) show that the effect becomes smaller at increasing gravity levels. From these results it is concluded that a dc approximation, which is generally assumed by lamp developers, is allowed for this MH lamp.

  16. Regulated-current dc power supply for gaseous-discharge lamps

    Science.gov (United States)

    Freeman, W.; Huguenin, D.

    1970-01-01

    Controlled current source having a high output resistance feeds continuous-flow hydrogen lamps in vacuum-ultraviolet photometric equipment. The power supply, also used with low-pressure sealed lamps, has a short recovery time and smooth regulation without overshoot.

  17. Evaluation of heat transfer coefficient of tungsten filaments at low pressures and high temperatures

    International Nuclear Information System (INIS)

    Chondrakis, N.G.; Topalis, F.V.

    2011-01-01

    The paper presents an experimental method for the evaluation of the heat transfer coefficient of tungsten filaments at low pressures and high temperatures. For this purpose an electrode of a T5 fluorescent lamp was tested under low pressures with simultaneous heating in order to simulate the starting conditions in the lamp. It was placed in a sealed vessel in which the pressure was varied from 1 kM (kilo micron) to 760 kM. The voltage applied to the electrode was in the order of the filament's voltage of the lamp at the normal operation with the ballast during the preheating process. The operating frequency ranged from DC to 50 kHz. The experiment targeted on estimating the temperature of the electrode at the end of the first and the ninth second after initiating the heating process. Next, the heat transfer coefficient was calculated at the specific experimental conditions. A mathematical model based on the results was developed that estimates the heat transfer coefficient. The experiments under different pressures confirm that the filament's temperature strongly depends on the pressure.

  18. Influence of Voltage on Main Characteristics of Electric Lighting Lamps

    Directory of Open Access Journals (Sweden)

    V. B. Kozlovskaya

    2009-01-01

    Full Text Available An analysis and systemization of data on influence of voltage value on main lighting engineering, electric and economic characteristics of incandescent lamps, gaseous-discharge lamps of low and high pressure have been made in the paper.Analytical and graphical dependences have been obtained that ensure to evaluate quantitative changes of corresponding lamp characteristics at voltage deviation from nominal value.

  19. 76 FR 70547 - Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts

    Science.gov (United States)

    2011-11-14

    ... the term ``fluorescent lamp,'' which EPCA defines as ``a low pressure mercury electric-discharge... discharge into light,'' and as including the four enumerated types of fluorescent lamps for which EPCA... Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts; Final Rule #0;#0;Federal...

  20. Thomson scattering on a low-pressure, inductively-coupled gas discharge lamp

    NARCIS (Netherlands)

    Sande, van de M.J.; Mullen, van der J.J.A.M.

    2002-01-01

    Excitation and light production processes in gas discharge lamps are the result of inelastic collisions between atoms and free electrons in the plasma. Therefore, knowledge of the electron density ne and temperature Te is essential for a proper understanding of such plasmas. In this paper, an

  1. Ignition of mercury-free high intensity discharge lamps

    International Nuclear Information System (INIS)

    Czichy, M; Mentel, J; Awakowicz, P; Hartmann, T

    2008-01-01

    To achieve a better understanding of the ignition behaviour of D4 lamps for automotive headlights the ignition of mercury-free metal iodide test lamps characterized by a high xenon pressure, a small electrode distance and small electrode-wall distances is investigated. The ignition of these lamps is dominated by a high voltage requirement. Nevertheless lamps are found that show a surprisingly low ignition voltage. Electrical measurements and simultaneous optical observations of the ultra-fast streamer processes show that the breakdown takes place in two different modes. One of the ignition modes which requires a high ignition voltage is characterized by a breakdown in the volume between the electrode tips. The other mode is characterized by streamer discharges along the wall. In this case the cathode, its base and the wall around is involved in the ignition process and the lamp breaks down at low voltages

  2. Nuclear radiation detected optical pumping of neutron deficient Hg isotopes

    International Nuclear Information System (INIS)

    Bonn, J.

    1975-01-01

    The extension of the Nuclear Radiation Detected Optical Pumping method to mass-separated samples of isotopes far off stability is presented for a series of light Hg isotopes produced at the ISOLDE facility at CERN. The isotope under investigation is transferred by an automatic transfer system into the optical pumping apparatus. Zeeman scanning of an isotopically pure Hg spectral lamp is used to reach energetic coincidence with the hyperfine structure components of the 6s 2 1 S 0 -6s6p 3 P 1 (lambda = 2537 A) resonance line of the investigated isotope and the Hg lamp. The orientation build up by optical pumping is monitored via the asymmetry or anisotropy of the nuclear radiation. Nuclear spins, magnetic moments, electric quadrupole moments and isotopic shift are obtained for 181 Hg- 191 Hg using the β-asymmetry as detector. The extension of the method using the γ-anisotropy is discussed and measurements on 193 Hg are presented. (orig./HK)

  3. Incident Cardiovascular Disease Among Adults With Blood Pressure Hg.

    Science.gov (United States)

    Tajeu, Gabriel S; Booth, John N; Colantonio, Lisandro D; Gottesman, Rebecca F; Howard, George; Lackland, Daniel T; O'Brien, Emily C; Oparil, Suzanne; Ravenell, Joseph; Safford, Monika M; Seals, Samantha R; Shimbo, Daichi; Shea, Steven; Spruill, Tanya M; Tanner, Rikki M; Muntner, Paul

    2017-08-29

    Data from before the 2000s indicate that the majority of incident cardiovascular disease (CVD) events occur among US adults with systolic and diastolic blood pressure (SBP/DBP) ≥140/90 mm Hg. Over the past several decades, BP has declined and hypertension control has improved. We estimated the percentage of incident CVD events that occur at SBP/DBP Hg in a pooled analysis of 3 contemporary US cohorts: the REGARDS study (Reasons for Geographic and Racial Differences in Stroke), the MESA (Multi-Ethnic Study of Atherosclerosis), and the JHS (Jackson Heart Study) (n=31 856; REGARDS=21 208; MESA=6779; JHS=3869). Baseline study visits were conducted in 2003 to 2007 for REGARDS, 2000 to 2002 for MESA, and 2000 to 2004 for JHS. BP was measured by trained staff using standardized methods. Antihypertensive medication use was self-reported. The primary outcome was incident CVD, defined by the first occurrence of fatal or nonfatal stroke, nonfatal myocardial infarction, fatal coronary heart disease, or heart failure. Events were adjudicated in each study. Over a mean follow-up of 7.7 years, 2584 participants had incident CVD events. Overall, 63.0% (95% confidence interval [CI], 54.9-71.1) of events occurred in participants with SBP/DBP Hg; 58.4% (95% CI, 47.7-69.2) and 68.1% (95% CI, 60.1-76.0) among those taking and not taking antihypertensive medication, respectively. The majority of events occurred in participants with SBP/DBP Hg among those Hg, 76.6% (95% CI, 75.8-77.5) were eligible for statin treatment, but only 33.2% (95% CI, 32.1-34.3) were taking one, and 19.5% (95% CI, 18.5-20.5) met the SPRINT (Systolic Blood Pressure Intervention Trial) eligibility criteria and may benefit from a SBP target goal of 120 mm Hg. Although higher BP levels are associated with increased CVD risk, in the modern era, the majority of incident CVD events occur in US adults with SBP/DBP Hg. While absolute risk and cost-effectiveness should be considered, additional CVD risk

  4. Apparatus for isotopic alteration of mercury vapor

    International Nuclear Information System (INIS)

    Grossman, M.W.; George, W.A.; Marcucci, R.V.

    1988-01-01

    This patent describes an apparatus for enriching the isotopic content of mercury. It comprises: a low pressure electric discharge lamp, the lamp comprising an envelope transparent to ultraviolet radiation and containing a fill comprising mercury and an inert gas; a filter concentrically arranged around the low pressure electric discharge lamp, the filter being transparent to ultraviolet radiation and containing mercury including 196 Hg isotope; means for controlling mercury pressure in the filter; and a reactor arranged around the filter such that radiation passes from the low pressure electric discharge lamp through the filter and into Said reactor, the reactor being transparent to ultraviolet light

  5. Integrity Monitoring of Mercury Discharge Lamps

    Science.gov (United States)

    Tjoelker, Robert L.

    2010-01-01

    Mercury discharge lamps are critical in many trapped ion frequency standard applications. An integrity monitoring system can be implemented using end-of-life signatures observed in operational mercury discharge lamps, making it possible to forecast imminent failure and to take action to mitigate the consequences (such as switching to a redundant system). Mercury lamps are used as a source of 194-nm ultraviolet radiation for optical pumping and state selection of mercury trapped ion frequency standards. Lamps are typically fabricated using 202Hg distilled into high-purity quartz, or other 194-nm transmitting material (e.g., sapphire). A buffer gas is also placed into the bulb, typically a noble gas such as argon, neon, or krypton. The bulbs are driven by strong RF fields oscillating at .200 MHz. The lamp output may age over time by two internal mechanisms: (1) the darkening of the bulb that attenuates light transmission and (2) the loss of mercury due to migration or chemical interactions with the bulb surface. During fabrication, excess mercury is placed into a bulb, so that the loss rate is compensated with new mercury emanating from a cool tip or adjacent reservoir. The light output is nearly constant or varies slightly at a constant rate for many months/years until the mercury source is depleted. At this point, the vapor pressure abruptly falls and the total light output and atomic clock SNR (signal-to-noise ratio) decrease. After several days to weeks, the light levels decrease to a point where the atomic clock SNR is no longer sufficient to stay in lock, or the lamp self-extinguishes. This signature has been observed in four separate end-of-life lamp failures while operating in the Deep Space Network (DSN). A simple integrator circuit can observe and document steady-state lamp behavior. When the light levels drop over a predetermined time interval by a specified amount (e.g., 20 percent), an alarm is set. For critical operational applications, such as the DSN

  6. High pressure microwave discharge for electrodeless Xe-lamp

    International Nuclear Information System (INIS)

    Kudela, J.; Kando, M.

    1998-01-01

    Preliminary results are presented of the investigation into the high pressure Xe microwave discharge in bent tubes, sustained by electromagnetic surface wave. The research was aimed to help with the design of a new generation of high intensity light sources with generally more complex shapes than those commonly used. The results show that the electromagnetic surface wave can effectively sustain discharge in tubes with various bending radii within the large pressure range. The curved shapes of discharge tubes improve the cooling of the lamp which is one of the major technological difficulties. It was shown that under relatively lower powers and higher gas pressures (100 Torr) the discharge exhibits a streamer-like filamentation and the branching of filaments. The phenomena of the effective sustaining of the discharge by surface wave propagation along curved plasma columns will be investigated in more detail by measurements of the profiles of surface wave electric and magnetic field intensities. (author)

  7. Appraisal of Bleb Using Trio of Intraocular Pressure, Morphology on Slit Lamp, and Gonioscopy

    OpenAIRE

    Thatte, Shreya; Rana, Rimpi; Gaur, Neeraj

    2016-01-01

    Purpose The aim of this study was to assess bleb function using Wuerzburg bleb classification score (WBCS) for bleb morphology on slit lamp, intraocular pressure (IOP), and gonioscopy. Methods A total of randomly selected 30 eyes posttrabeculectomy were assessed for bleb function with the trio of bleb morphology, IOP, and gonioscopy. Bleb was assessed using the WBCS of 0–12 on slit lamp, IOP was assessed using applanation tonometry, and visualization of inner ostium and iridectomy were assess...

  8. Microplasma light tiles: thin sheet lamps for general illumination

    Energy Technology Data Exchange (ETDEWEB)

    Eden, J G; Park, S-J [Laboratory for Optical Physics and Engineering, Department of Electrical and Computer Engineering, University of Illinois, Urbana, IL 61801 (United States); Herring, C M; Bulson, J M [Eden Park Illumination, 903 North Country Fair Drive, Champaign, IL 61821 (United States)

    2011-06-08

    Flat, thin and lightweight lamps providing spatially uniform and dimmable illumination from active areas as large as 400 cm{sup 2} are being developed for general illumination and specialty applications. Comprising an array of low-temperature, nonequilibrium microplasmas driven by a dielectric barrier structure and operating at pressures of typically 400-700 Torr, these lamps have a packaged thickness <4 mm and yet produce luminance values beyond 26 000 cd m{sup -2} with a luminous efficacy approaching 30 lm W{sup -1}. Third generation lamps, presently in limited production, offer a correlated colour temperature in the 3000-4100 K interval and a colour rendering index of 80. Current lamps employ Xe{sub 2} ({lambda} {approx} 172 nm) as the primary emitter photoexciting a mixture of phosphors, and the pressure dependence of the wavelength-integrated fluorescence from the electronically excited dimer has been investigated with a vacuum ultraviolet spectrometer. In contrast to other promising lighting technologies, the decline in luminous efficacy of microplasma lamps with increasing power delivered to the lamp is small. For a 6 x 6 inch{sup 2} ({approx}225 cm{sup 2}) lamp, efficacy falls <16% when the radiant output (luminance) is raised from 2000 cd m{sup -2} to > 10 000 cd m{sup -2}.

  9. Intraocular pressure in very low birth weight preterm infants and its association with postconceptional age

    Directory of Open Access Journals (Sweden)

    Rodrigo L. Lindenmeyer

    2012-11-01

    Full Text Available OBJECTIVE: To evaluate intraocular pressure in very low birth weight preterm infants and correlate it with postconceptional age. METHODS: The intraocular pressure in a prospective cohort of very low birth weight premature infants (defined as a birth weight <1,500 g and gestational age <32 weeks admitted to Hospital de Clínicas de Porto Alegre , Brazil was evaluated weekly. The evaluated outcome was the variation in the intraocular pressure following changes in the postconceptional age (defined as the gestational age at birth plus the age in weeks at the time of examination in the weeks following preterm birth. Mixed-effects models were used for the statistical analysis to determine the intraocular pressure variation according to postconceptional age, and means and 10th and 90th percentiles were calculated for the intraocular pressure values. RESULTS: Fifty preterm infants with a mean gestational age of 29.7 ± 1.6 weeks and a mean birth weight of 1,127.7 ± 222.7 g were evaluated. The mean intraocular pressure for the entire cohort considering both eyes was 14.9 ± 4.5 mmHg, and 13.5% of all recorded intraocular pressure values were greater than 20 mmHg. The analysis revealed a mean reduction in the intraocular pressure of 0.29 mmHg for each increase in postconceptional age (p = 0.047; 95% CI: -0.58 to -0.0035. The mean intraocular pressure (P10-P90 decreased from 16.3 mmHg (10.5222.16 at 26.3 weeks to 13.1 mmHg (7.28-18.92 at 37.6 weeks of postconceptional age. CONCLUSIONS: The mean intraocular pressure in very low birth weight preterm infants was 14.9 ± 4.5 mmHg. This value decreased 0.29 mmHg per week as the postconceptional age increased.

  10. Beer Law Constants and Vapor Pressures of HgI2 over HgI2(s,l)

    Science.gov (United States)

    Su, Ching-Hua; Zhu, Shen; Ramachandran, N.; Burger, A.

    2002-01-01

    Optical absorption spectra of the vapor phase over HgI2(s,l) were measured at sample temperatures between 349 and 610 K for wavelengths between 200 and 600 nm. The spectra show the samples sublimed congruently into HGI2 without any observed Hg or I2 absorption spectra. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were derived. From these constants the vapor pressure of HgI2, P, was found to be a function of temperature for the liquid and the solid beta-phases: ln P(atm) = -7700/T(K) + 12.462 (liquid phase) and ln P(atm) = -10150/T(K) + 17.026 (beta-phase). The expressions match the enthalpies of vaporization and sublimation of 15.30 and 20.17 kcal/mole respectively, for the liquid and the beta-phase HgI2. The difference in the enthalpies gives an enthalpy of fusion of 4.87 kcal/mole, and the intersection of the two expressions gives a melting point of 537 K.

  11. Low diastolic blood pressure and adverse outcomes in heart failure with preserved ejection fraction.

    Science.gov (United States)

    Tsujimoto, Tetsuro; Kajio, Hiroshi

    2018-07-15

    It remains unknown whether a low diastolic blood pressure (DBP) increases the risks of cardiovascular events and death in patients with heart failure with preserved ejection fraction (HFpEF). We used data from the TOPCAT trial. The primary outcome was a composite of all-cause death, non-fatal myocardial infarction, non-fatal stroke, or hospitalization for heart failure. Hazard ratios (HRs) were analyzed for DBPs of <60, 60-69, 70-79, and ≥90 mm Hg in comparison with a DBP of 80-89 mm Hg using multivariable Cox proportional hazard models. This study included 3417 patients with HFpEF who had a controlled blood pressure. In the mean follow-up period of 3.0 years, 881 patients experienced at least one confirmed primary outcome event. Compared with patients with a DBP of 80-89 mm Hg, the adjusted HRs for primary outcome events were significantly higher in those with DBPs of <60 mm Hg (HR: 2.19 [95% confidence interval,1.72-2.78]) and 60-69 mm Hg (HR: 1.52 [1.23-1.87]). Similarly, the adjusted HRs for all-cause death, major cardiovascular events, and hospitalization for heart failure, but not stroke, were significantly higher in patients with a DBP of <70 mm Hg. A relationship between a low DBP and adverse outcomes was found in HFpEF patients with a systolic blood pressure of ≥120 mm Hg; however, a low systolic blood pressure with a DBP of ≥70 mm Hg was not associated with these event risks. A low DBP increased the risks of adverse outcomes in patients with HFpEF. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  12. The gas phase emitter effect of lanthanum within ceramic metal halide lamps and its dependence on the La vapor pressure and operating frequency

    Energy Technology Data Exchange (ETDEWEB)

    Ruhrmann, C.; Hoebing, T.; Bergner, A.; Groeger, S.; Awakowicz, P.; Mentel, J. [Electrical Engineering and Plasma Technology, Ruhr University Bochum, D-44780 Bochum (Germany); Denissen, C.; Suijker, J. [Philips Lighting, Category Professional Lamps, P.O. Box 80020, NL-5600JM Eindhoven (Netherlands)

    2015-08-07

    The gas phase emitter effect increases the lamp lifetime by lowering the work function and, with it, the temperature of the tungsten electrodes of metal halide lamps especially for lamps in ceramic vessels due to their high rare earth pressures. It is generated by a monolayer on the electrode surface of electropositive atoms of certain emitter elements, which are inserted into the lamp bulb by metal iodide salts. They are vaporized, dissociated, ionized, and deposited by an emitter ion current onto the electrode surface within the cathodic phase of lamp operation with a switched-dc or ac-current. The gas phase emitter effect of La and the influence of Na on the emitter effect of La are studied by spatially and phase-resolved pyrometric measurements of the electrode tip temperature, La atom, and ion densities by optical emission spectroscopy as well as optical broadband absorption spectroscopy and arc attachment images by short time photography. An addition of Na to the lamp filling increases the La vapor pressure within the lamp considerably, resulting in an improved gas phase emitter effect of La. Furthermore, the La vapor pressure is raised by a heating of the cold spot. In this way, conditions depending on the La vapor pressure and operating frequency are identified, at which the temperature of the electrodes becomes a minimum.

  13. Optical and electrostatic potential investigations of electrical breakdown phenomena in a low-pressure gas discharge lamp

    International Nuclear Information System (INIS)

    Gendre, M F; Haverlag, M; Kroesen, G M W

    2010-01-01

    The ignition phase is a critical stage in the operation of gas discharge lamps where the neutral gas enclosed between the electrodes undergoes a transformation from the dielectric state to a conducting phase, eventually enabling the production of light. The phenomena occurring during this phase transition are not fully understood and the related experimental studies are often limited to local optical measurements in environments prone to influencing these transient phenomena. In this work unipolar ignition phenomena at sub-kilovolt levels are investigated in a 3 Torr argon discharge tube. The lamp is placed in a highly controlled environment so as to prevent any bias on the measurements. A fast intensified CCD camera and a specially designed novel electrostatic probe are used simultaneously so as to provide a broad array of measured and computed parameters which are displayed in space-time diagrams for cross comparisons. Experiments show that three distinct phases exist during successful ignitions: upon the application of voltage a first ionization wave starts from the active electrode and propagates in the neutral gas towards the opposite electrode. A local front of high axial E field strength is associated with this process and causes a local ionization to occur, leading to the electrostatic charging of the lamp. Next, a second wave propagates from the ground electrode back towards the active electrode with a higher velocity, and in this process leads to a partial discharging of the lamp. This return stroke draws a homogeneous plasma column which eventually bridges both electrodes at the end of the wave propagation. At this point both electrode sheaths are formed and the common features of a glow discharge are observed. The third phase is an increase in the light intensity of the plasma column until the lamp reaches a steady-state operation. Failed ignitions present only the first phase where the first wave starts its propagation but extinguishes in the lamp

  14. Thermodynamic properties of the liquid Hg-Tl alloys determined from vapour pressure measurements

    Directory of Open Access Journals (Sweden)

    Gierlotka W.

    2002-01-01

    Full Text Available The partial vapour pressure of mercury over liquid Hg-Tl liquid solutions were determined in the temperature range from 450 to 700 K by direct vapour pressure measurements carried out with the quartz gauge. From the measured ln pHg vs. T relationships activities of mercury were determined. Using Redlich-Kister formulas logarithms of the activity coefficients were described with the following equations: From which all thermodynamic functions in the solutions can be derived.

  15. Randomized trial of low versus high carbon dioxide insufflation pressures in posterior retroperitoneoscopic adrenalectomy.

    Science.gov (United States)

    Fraser, Sheila; Norlén, Olov; Bender, Kyle; Davidson, Joanne; Bajenov, Sonya; Fahey, David; Li, Shawn; Sidhu, Stan; Sywak, Mark

    2018-05-01

    Posterior retroperitoneoscopic adrenalectomy has gained widespread acceptance for the removal of benign adrenal tumors. Higher insufflation pressures using carbon dioxide (CO 2 ) are required, although the ideal starting pressure is unclear. This prospective, randomized, single-blinded, study aims to compare physiologic differences with 2 different CO 2 insufflation pressures during posterior retroperitoneoscopic adrenalectomy. Participants were randomly assigned to a starting insufflation pressure of 20 mm Hg (low pressure) or 25 mm Hg (high pressure). The primary outcome measure was partial pressure of arterial CO 2 at 60 minutes. Secondary outcomes included end-tidal CO 2 , arterial pH, blood pressure, and peak airway pressure. Breaches of protocol to change insufflation pressure were permitted if required and were recorded. A prospective randomized trial including 31 patients (low pressure: n = 16; high pressure: n = 15) was undertaken. At 60 minutes, the high pressure group had greater mean partial pressure of arterial CO 2 (64 vs 50 mm Hg, P = .003) and end-tidal CO 2 (54 vs 45 mm Hg, P = .008) and a lesser pH (7.21 vs 7.29, P = .0005). There were no significant differences in base excess, peak airway pressure, operative time, or duration of hospital stay. Clinically indicated protocol breaches were more common in the low pressure than the high pressure group (8 vs 3, P = .03). In posterior retroperitoneoscopic adrenalectomy, greater insufflation pressures are associated with greater partial pressure of arterial CO 2 and end-tidal CO 2 and lesser pH at 60 minutes, be significant. Commencing with lesser CO 2 insufflation pressures decreases intraoperative acidosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Harmonics Study of Common Low Wattage LED Lamps

    Directory of Open Access Journals (Sweden)

    Ioan Dragoş Deaconu

    2017-11-01

    Full Text Available This article presents experimental data on Light Emitting Diode (LED lamps of low wattage that are commonly found both in commercial and residential applications. A comparison with the existing regulations is performed. The measurements are performed using power and energy quality analyzer intended also for avionic and military systems.

  17. Estimated Trans-Lamina Cribrosa Pressure Differences in Low-Teen and High-Teen Intraocular Pressure Normal Tension Glaucoma: The Korean National Health and Nutrition Examination Survey.

    Directory of Open Access Journals (Sweden)

    Si Hyung Lee

    Full Text Available To investigate the association between estimated trans-lamina cribrosa pressure difference (TLCPD and prevalence of normal tension glaucoma (NTG with low-teen and high-teen intraocular pressure (IOP using a population-based study design.A total of 12,743 adults (≥ 40 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES from 2009 to 2012 were included. Using a previously developed formula, cerebrospinal fluid pressure (CSFP in mmHg was estimated as 0.55 × body mass index (kg/m2 + 0.16 × diastolic blood pressure (mmHg-0.18 × age (years-1.91. TLCPD was calculated as IOP-CSFP. The NTG subjects were divided into two groups according to IOP level: low-teen NTG (IOP ≤ 15 mmHg and high-teen NTG (15 mmHg < IOP ≤ 21 mmHg groups. The association between TLCPD and the prevalence of NTG was assessed in the low- and high-teen IOP groups.In the normal population (n = 12,069, the weighted mean estimated CSFP was 11.69 ± 0.04 mmHg and the weighted mean TLCPD 2.31 ± 0.06 mmHg. Significantly higher TLCPD (p < 0.001; 6.48 ± 0.27 mmHg was found in the high-teen NTG compared with the normal group. On the other hand, there was no significant difference in TLCPD between normal and low-teen NTG subjects (p = 0.395; 2.31 ± 0.06 vs. 2.11 ± 0.24 mmHg. Multivariate logistic regression analysis revealed that TLCPD was significantly associated with the prevalence of NTG in the high-teen IOP group (p = 0.006; OR: 1.09; 95% CI: 1.02, 1.15, but not the low-teen IOP group (p = 0.636. Instead, the presence of hypertension was significantly associated with the prevalence of NTG in the low-teen IOP group (p < 0.001; OR: 1.65; 95% CI: 1.26, 2.16.TLCPD was significantly associated with the prevalence of NTG in high-teen IOP subjects, but not low-teen IOP subjects, in whom hypertension may be more closely associated. This study suggests that the underlying mechanisms may differ between low-teen and high-teen NTG patients.

  18. Life-cycle flow of mercury and recycling scenario of fluorescent lamps in Japan.

    Science.gov (United States)

    Asari, Misuzu; Fukui, Kazuki; Sakai, Shin-Ichi

    2008-04-01

    We summarized the mercury flow of mercury-containing products from their manufacture to their disposal in Japan and discussed the current management of mercury-containing hazardous household waste (HHW). The mercury flow originating from these products was estimated to be about 10-20 tonnes annually, about 5 tonnes of which was attributable to fluorescent lamps, the major mercury-containing product in Japan. The recent rapid increase in digital home electronics with liquid crystal displays (e.g.,televisions, personal computers, mobile phones, and digital cameras) has led to a marked increase in the production of backlights, which are also fluorescent and contain mercury. Most of the annual flow was disposed of as waste, with only 0.6 tonnes Hg recovered. The mercury flow for end-of-life fluorescent lamps (excluding backlights) was analyzed under three scenarios for Kyoto, Japan for 2003: the present condition scenario, the improved recycling scenario, and the complete recycling scenario. Under the present condition scenario, mercury flow was calculated to be 34 kg Hg for incineration, 21 kg Hg for landfill, and only 4 kg Hg for recycling. The complete recycling scenario shows a simple flow, with all mercury recycled. Under this scenario for Kyoto, we calculated that a cyclic system having 47 kg of mercury (3.5 tonnes Hg in Japan) could be established if all fluorescent lamps (excluding those stored in residences) were collected and recycled. Mercury is a HHW priority chemical, and we need to limit its use and establish a closed-loop system. There are currently no regulations to achieve this, and the management of most HHWs is left to local governments. Therefore, products are disposed of in landfills or incinerated, except for some that are voluntarily collected and recycled. In order to recycle all of the waste fluorescent lamps, we must have a complete recycling system that has a high rate of public participation in collection. We also must have a closed

  19. Life-cycle flow of mercury and recycling scenario of fluorescent lamps in Japan

    International Nuclear Information System (INIS)

    Asari, Misuzu; Fukui, Kazuki; Sakai, Shin-ichi

    2008-01-01

    We summarized the mercury flow of mercury-containing products from their manufacture to their disposal in Japan and discussed the current management of mercury-containing hazardous household waste (HHW). The mercury flow originating from these products was estimated to be about 10-20 tonnes annually, about 5 tonnes of which was attributable to fluorescent lamps, the major mercury-containing product in Japan. The recent rapid increase in digital home electronics with liquid crystal displays (e.g., televisions, personal computers, mobile phones, and digital cameras) has led to a marked increase in the production of backlights, which are also fluorescent and contain mercury. Most of the annual flow was disposed of as waste, with only 0.6 tonnes Hg recovered. The mercury flow for end-of-life fluorescent lamps (excluding backlights) was analyzed under three scenarios for Kyoto, Japan for 2003: the present condition scenario, the improved recycling scenario, and the complete recycling scenario. Under the present condition scenario, mercury flow was calculated to be 34 kg Hg for incineration, 21 kg Hg for landfill, and only 4 kg Hg for recycling. The complete recycling scenario shows a simple flow, with all mercury recycled. Under this scenario for Kyoto, we calculated that a cyclic system having 47 kg of mercury (3.5 tonnes Hg in Japan) could be established if all fluorescent lamps (excluding those stored in residences) were collected and recycled. Mercury is a HHW priority chemical, and we need to limit its use and establish a closed-loop system. There are currently no regulations to achieve this, and the management of most HHWs is left to local governments. Therefore, products are disposed of in landfills or incinerated, except for some that are voluntarily collected and recycled. In order to recycle all of the waste fluorescent lamps, we must have a complete recycling system that has a high rate of public participation in collection. We also must have a closed

  20. Helium Pressure Shift of the Hyperfine Clock Transition in Hg-201(+)

    Science.gov (United States)

    Larigani, S. Taghavi; Burt, E. A.; Tjoelker, R. L.

    2010-01-01

    There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave atomic clock: Hg-199(+) and Hg-201(+). We are investigating the viability of a trapped ion clock based on Hg-201(+) in a configuration that uses a buffer gas to increase ion loading efficiency and counter ion heating from rf trapping fields. Traditionally, either helium or neon is used as the buffer gas at approx. 10(exp -5) torr to confine mercury ions near room temperature. In addition to the buffer gas, other residual background gasses such as H2O, N2, O2, CO, CO2, and CH2 may be present in trace quantities. Collisions between trapped ions and buffer gas or background gas atoms/molecules produce a momentary shift of the ion clock transition frequency and constitute one of the largest systematic effects in this type of clock. Here we report an initial measurement of the He pressure shift in Hg-201(+) and compare this to Hg-199(+).

  1. Postoperative shoulder pain after laparoscopic hysterectomy with deep neuromuscular blockade and low-pressure pneumoperitoneum

    DEFF Research Database (Denmark)

    Madsen, Matias Vested; Istre, Olav; Staehr-Rye, Anne K

    2016-01-01

    indicate that the use of deep neuromuscular blockade (NMB) improves surgical conditions during a low-pressure pneumoperitoneum (8 mmHg). OBJECTIVE: The aim of this study was to investigate whether low-pressure pneumoperitoneum (8 mmHg) and deep NMB (posttetanic count 0 to 1) compared with standard......: Ninety-nine patients. INTERVENTIONS: Randomisation to either deep NMB and 8 mmHg pneumoperitoneum (Group 8-Deep) or moderate NMB and 12 mmHg pneumoperitoneum (Group 12-Mod). Pain was assessed on a visual analogue scale (VAS) for 14 postoperative days. MAIN OUTCOME MEASURES: The primary endpoint...... was the incidence of shoulder pain during 14 postoperative days. Secondary endpoints included area under curve VAS scores for shoulder, abdominal, incisional and overall pain during 4 and 14 postoperative days; opioid consumption; incidence of nausea and vomiting; antiemetic consumption; time to recovery...

  2. Change of the arc attachment mode and its effect on the lifetime in automotive high intensity discharge lamps

    Science.gov (United States)

    Alexejev, Alexander; Flesch, Peter; Mentel, Jürgen; Awakowicz, Peter

    2016-10-01

    In modern cars, the new generation Hg-free high intensity discharge (HID) lamps, the so called xenon lamps, take an important role. The long lifetime of these lamps is achieved by doping the tungsten electrodes with thorium. Thorium forms a dipole layer on the electrode surface, thus reducing the work function of tungsten. However, thoriating the electrodes is also an issue of trade and transport regulation, so a substitute is looked into. This work shows the influence of the arc attachment mode on the lifetime of the lamps. The mode of the arc attachment changes during the run-up phase of automotive HID lamps after a characteristic time period depending, i.e., on the filling of the lamps, which is dominated by scandium. It will be shown that this characteristic time period for the change of the attachment mode determines the long term performance of Hg-free xenon lamps. Measurements attributing the mode change to the scandium density in the filling are presented. The emitter effect of scandium will be suggested to be the reason of the mode change.

  3. Distinct toxicological characteristics and mechanisms of Hg2+ and MeHg in Tetrahymena under low concentration exposure.

    Science.gov (United States)

    Liu, Cheng-Bin; Qu, Guang-Bo; Cao, Meng-Xi; Liang, Yong; Hu, Li-Gang; Shi, Jian-Bo; Cai, Yong; Jiang, Gui-Bin

    2017-12-01

    Inorganic divalent mercury complexes (Hg 2+ ) and monomethylmercury complexes (MeHg) are the main mercury species in aquatic systems and their toxicity to aquatic organisms is of great concern. Tetrahymena is a type of unicellular eukaryotic protozoa located at the bottom of food chain that plays a fundamental role in the biomagnification of mercury. In this work, the dynamic accumulation properties, toxicological characteristics and mechanisms of Hg 2+ and MeHg in five Tetrahymena species were evaluated in detail. The results showed that both Hg 2+ and MeHg were ingested and exhibited inhibitory effects on the proliferation or survival of Tetrahymena species. However, the ingestion rate of MeHg was significantly higher than that of Hg 2+ . The mechanisms responsible for the toxicity of MeHg and Hg 2+ were different, although both chemicals altered mitochondrial membrane potential (MMP). MeHg disrupted the integrity of membranes while Hg 2+ had detrimental effects on Tetrahymena as a result of the increased generation of reactive oxygen species (ROS). In addition, the five Tetrahymena species showed different capacities in accumulating Hg 2+ and MeHg, with T. corlissi exhibiting the highest accumulations. The study also found significant growth-promoting effect on T. corlissi under low concentration exposure (0.003 and 0.01μg Hg/mL (15 and 50nM)), suggesting different effect and mechanism that should be more closely examined when assessing the bioaccumulation and toxicity of mercury in aquatic ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Low vs Standard Pressures in Gynecologic Laparoscopy: a Systematic Review.

    Science.gov (United States)

    Kyle, Esther B; Maheux-Lacroix, Sarah; Boutin, Amélie; Laberge, Philippe Y; Lemyre, Madeleine

    2016-01-01

    The optimal intraperitoneal pressure during laparoscopy is not known. Recent literature found benefits of using lower pressures, but the safety of doing abdominal surgery with low peritoneal pressures needs to be assessed. This systematic review compares low with standard pneumoperitoneum during gynecologic laparoscopy. We searched Medline, Embase, and the Cochrane Library for randomized controlled trials comparing intraperitoneal pressures during gynecologic laparoscopy. Two authors reviewed references and extracted data from included trials. Risk ratios, mean differences, and standard mean differences were calculated and pooled using RevMan5. Of 2251 studies identified, three were included in the systematic review, for a total of 238 patients. We found a statistically significant but modest diminution in postoperative pain of 0.38 standardized unit based on an original 10-point scale (95% confidence interval [CI], -0.67 to -0.08) during the immediate postoperative period when using low intraperitoneal pressure of 8 mm Hg compared with ≥ 12 mm Hg and of 0.50 (95% CI, -0.80 to -0.21) 24 hours after the surgery. Lower pressures were associated with worse visualization of the surgical field (risk ratio, 10.31; 95% CI, 1.29-82.38). We found no difference between groups over blood loss, duration of surgery, hospital length of stay, or the need for increased pressure. Low intraperitoneal pressures during gynecologic laparoscopy cannot be recommended on the behalf of this review because improvement in pain scores is minimal and visualization of the surgical field is affected. The safety of this intervention as well as cost-effectiveness considerations need to be further studied.

  5. Excimer lamp pumped by a triggered discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, G.; Bollanti, S.; Di Lazzaro, P.; Flora, F.; Giordano, G.; Letardi, T.; Renieri, A.; Schina, G. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Clementi, G.; Muzzi, F.; Zheng, C.E. [EL.EN. (Electronic Engineering), Florence (Italy)

    1996-11-01

    Radiation characteristics and discharge performances of an excimer lamp are described. The discharge of the HCl/Xe gas mixture at an atmospheric pressure, occurring near the quartz tube wall, is initiated by a trigger wire. A maximum total UV energy of about 0.4 J in a (0.8-0.9) {mu}s pulse, radiated from a 10 cm discharge length, is obtained with a total discharge input energy of 8 J. Excimer lamps are the preferred choice for medical and material processing irradiations, when the monochromaticity or coherence of UV light is not required, due to their low cost, reliability and easy maintenance.

  6. Iterative Boltzmann plot method for temperature and pressure determination in a xenon high pressure discharge lamp

    Energy Technology Data Exchange (ETDEWEB)

    Zalach, J.; Franke, St. [INP Greifswald, Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany)

    2013-01-28

    The Boltzmann plot method allows to calculate plasma temperatures and pressures if absolutely calibrated emission coefficients of spectral lines are available. However, xenon arcs are not very well suited to be analyzed this way, as there are only a limited number of lines with atomic data available. These lines have high excitation energies in a small interval between 9.8 and 11.5 eV. Uncertainties in the experimental method and in the atomic data further limit the accuracy of the evaluation procedure. This may result in implausible values of temperature and pressure with inadmissible uncertainty. To omit these shortcomings, an iterative scheme is proposed that is making use of additional information about the xenon fill pressure. This method is proved to be robust against noisy data and significantly reduces the uncertainties. Intentionally distorted synthetic data are used to illustrate the performance of the method, and measurements performed on a laboratory xenon high pressure discharge lamp are analyzed resulting in reasonable temperatures and pressures with significantly reduced uncertainties.

  7. Slit-lamp Needling of the Anterior Capsule for Aqueous Misdirection After Hyaloido-zonulectomy and Iridectomy.

    Science.gov (United States)

    Mardelli, Pierre G; Mardelli, Marc E

    2018-04-01

    We present a case of persistent aqueous misdirection, after Ahmed glaucoma valve surgery, despite undergoing an anterior vitrectomy with hyaloido-zonulectomy and iridectomy. A 73-year-old female patient, 4 months after phacotrabeculectomy, was referred with persistent high intraocular pressure (IOP). Postoperatively, she developed aqueous misdirection with a flat anterior chamber (AC) but with an IOP of 15 mm Hg. On presentation, her AC was shallow with peripheral iris-cornea touch, and her IOP was 39 mm Hg. Posterior Nd:Yag capsulotomy with disruption of anterior hyaloid face partially deepened the AC. With failure of the trabeculectomy and high IOP, an Ahmed valve was placed. On the first operative day the AC was deep with an IOP of 10 mm Hg. On day 6 the patient presented with pain, flat AC, and an IOP of 10 mm Hg. Fundus examination revealed no choroidal effusion. Despite repeated reformation with viscoelastic, the AC failed to deepen. An anterior vitrectomy with hyaloido-zonulectomy was performed. Initially, the AC was deep, but, a few days later, it was flat. Multiple reformations and vitreous tap failed to keep the AC deep. A 30-G needle was passed at the slit lamp across the temporal cornea, iris, and anterior capsule into the anterior vitreous cavity. The needle was then partially withdrawn and used to create a space between the intraocular lens and anterior capsule. This immediately deepened the AC and remained so for the duration of follow-up (4 mo). Slit-lamp needling of the anterior lens capsule can be successfully performed to help resolve a persistent case of aqueous misdirection after anterior vitrectomy.

  8. Experimental and theoretical characterization of a multi-wavelength DBD-driven exciplex lamp operated with mercury bromide/rare gas mixtures

    International Nuclear Information System (INIS)

    Guivan, Mykola M; Malinina, Antonina A; Brablec, Antonin

    2011-01-01

    Emission spectra from an atmospheric-pressure dielectric barrier discharge (DBD) with HgBr 2 /He or HgBr 2 /Xe/Kr mixtures, as well as the electrical characteristics, were investigated at repetition frequencies of sinusoidal voltage pulses up to 125 kHz. In the spectra, the study revealed radiation from HgBr(B-X, C-X) exciplex molecules, atomic lines of mercury and rare gases, and in mixtures with xenon, radiation of XeBr(B-X, B-A) exciplex molecules. Regularities in the spectral characteristics of the radiation from the gas-discharge plasma were discussed. The electron energy distribution function, the specific energy lost in the processes involving electrons, the electron temperature and density, and the rate constants of elastic and inelastic electron scattering by the components of the working mixture were calculated as functions of the reduced field E/N. The high-frequency atmospheric-pressure barrier discharge in mixtures of mercury dibromide with gases can be used in multi-wavelength exciplex lamps, operating in the UV and visible regions.

  9. Experimental and theoretical characterization of a multi-wavelength DBD-driven exciplex lamp operated with mercury bromide/rare gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Guivan, Mykola M; Malinina, Antonina A [Department of Quantum Electronics, Uzhgorod National University, Pidgirna 46, Uzhgorod 88000 (Ukraine); Brablec, Antonin, E-mail: m_guivan@rambler.ru [Department of Physical Electronics, Masaryk University, Kotlarska 2, Brno 61137 (Czech Republic)

    2011-06-08

    Emission spectra from an atmospheric-pressure dielectric barrier discharge (DBD) with HgBr{sub 2}/He or HgBr{sub 2}/Xe/Kr mixtures, as well as the electrical characteristics, were investigated at repetition frequencies of sinusoidal voltage pulses up to 125 kHz. In the spectra, the study revealed radiation from HgBr(B-X, C-X) exciplex molecules, atomic lines of mercury and rare gases, and in mixtures with xenon, radiation of XeBr(B-X, B-A) exciplex molecules. Regularities in the spectral characteristics of the radiation from the gas-discharge plasma were discussed. The electron energy distribution function, the specific energy lost in the processes involving electrons, the electron temperature and density, and the rate constants of elastic and inelastic electron scattering by the components of the working mixture were calculated as functions of the reduced field E/N. The high-frequency atmospheric-pressure barrier discharge in mixtures of mercury dibromide with gases can be used in multi-wavelength exciplex lamps, operating in the UV and visible regions.

  10. Crystal structure of HgGa{sub 2}Se{sub 4} under compression

    Energy Technology Data Exchange (ETDEWEB)

    Gomis, Oscar, E-mail: osgohi@fis.upv.es [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Vilaplana, Rosario [Centro de Tecnologías Físicas: Acústica, Materiales y Astrofísica, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Manjón, Francisco Javier [Instituto de Diseño para la Fabricación y Producción Automatizada, MALTA Consolider Team, Universitat Politècnica de València, 46022 València (Spain); Santamaría-Pérez, David [Departamento de Química Física I, Universidad Complutense de Madrid, MALTA Consolider Team, Avenida Complutense s/n, 28040 Madrid (Spain); Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universidad de Valencia, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 Valencia (Spain); Errandonea, Daniel [Departamento de Física Aplicada-ICMUV, MALTA Consolider Team, Universidad de Valencia, Edificio de Investigación, C/Dr. Moliner 50, Burjassot, 46100 Valencia (Spain); and others

    2013-06-01

    Highlights: ► Single crystals of HgGa{sub 2}Se{sub 4} with defect-chalcopyrite structure were synthesized. ► HgGa{sub 2}Se{sub 4} exhibits a phase transition to a disordered rock salt structure at 17 GPa. ► HgGa{sub 2}Se{sub 4} undergoes a phase transition below 2.1 GPa to a disordered zinc blende. - Abstract: We report on high-pressure x-ray diffraction measurements up to 17.2 GPa in mercury digallium selenide (HgGa{sub 2}Se{sub 4}). The equation of state and the axial compressibilities for the low-pressure tetragonal phase have been determined and compared to related compounds. HgGa{sub 2}Se{sub 4} exhibits a phase transition on upstroke toward a disordered rock-salt structure beyond 17 GPa, while on downstroke it undergoes a phase transition below 2.1 GPa to a phase that could be assigned to a metastable zinc-blende structure with a total cation-vacancy disorder. Thermal annealing at low- and high-pressure shows that kinetics plays an important role on pressure-driven transitions.

  11. Mercury-free high pressure discharge lamps dominated by molecular radiation

    International Nuclear Information System (INIS)

    Kaening, M; Hitzschke, L; Berger, M; Schalk, B; Franke, St; Methling, R

    2011-01-01

    High intensity discharge (HID) lamps dominated by molecular radiation offer a very promising alternative for use in future light sources. They are able to deliver competitive efficacies of about 110 lm W -1 and higher, excellent colour rendering index above 90 and a correlated colour temperature in the 3000-4000 K region at the operating point near the Planckian locus. Moreover, these lamps are opening up the possibility of dimming. Due to the fact that they are able to omit mercury they are environmentally friendly. The emission spectra generated by these HID lamps differ significantly from those of conventional lamps. The reason for this is the dominance of molecular radiation processes. In comparison with conventional HID lamps atomic contributions are usually rather small. In the present case they amount to less than about 10% of the total intensity in the visible range.

  12. Mercury-free high pressure discharge lamps dominated by molecular radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kaening, M; Hitzschke, L; Berger, M [Research Europe, OSRAM GmbH, Werner-von-Siemens Strasse 6, 86159 Augsburg (Germany); Schalk, B [Vitec Group Videocom Division, Erfurter Strasse 16, 85386 Eching (Germany); Franke, St; Methling, R, E-mail: m.kaening@osram.de [INP, Leibniz-Institut fuer Plasmaforschung und Technologie e. V., Felix-Hausdorff-Strasse 2, 17489 Greifswald (Germany)

    2011-06-08

    High intensity discharge (HID) lamps dominated by molecular radiation offer a very promising alternative for use in future light sources. They are able to deliver competitive efficacies of about 110 lm W{sup -1} and higher, excellent colour rendering index above 90 and a correlated colour temperature in the 3000-4000 K region at the operating point near the Planckian locus. Moreover, these lamps are opening up the possibility of dimming. Due to the fact that they are able to omit mercury they are environmentally friendly. The emission spectra generated by these HID lamps differ significantly from those of conventional lamps. The reason for this is the dominance of molecular radiation processes. In comparison with conventional HID lamps atomic contributions are usually rather small. In the present case they amount to less than about 10% of the total intensity in the visible range.

  13. Axial mercury segregation in direct current operated low-pressure argon-mercury gas discharges: Part I. Experimental

    International Nuclear Information System (INIS)

    Gielen, John W A M; Groot, Simon de; Mullen, Joost J A M van der

    2004-01-01

    Due to cataphoresis, axial segregation of mercury will occur when the gas discharge of a fluorescent lamp is operated by means of a direct current. A consequence of this is a non-uniform axial luminance distribution along the lamp. To determine the degree of axial mercury segregation experimentally, axial luminance distributions have been measured which are converted into axial mercury vapour pressure distributions by an appropriate calibration method. The mercury segregation has been investigated for variations in lamp tube radius (3.6-4.8 mm), argon buffer gas pressure (200-600 Pa) and lamp current (100-250 mA) at mercury vapour pressures set at the anode in the range from 0.2 to 9.0 Pa. From the experiments it has been concluded that the mercury vapour pressure gradient at any axial position for a certain lamp tube diameter, argon pressure and lamp current depends on the local mercury vapour pressure. This observation is in contrast to assumptions made in earlier modelling publications in which one mercury vapour pressure gradient is used for all axial positions. By applying a full factorial design, an empirical relation of the mercury segregation is found for any set of parameters inside the investigated parameter ranges

  14. Photodegradation of 17α-ethynylestradiol in aqueous solution exposed to a high-pressure mercury lamp (250 W)

    International Nuclear Information System (INIS)

    Liu, X.L.; Wu, F.; Deng, N.S.

    2003-01-01

    The photodegradation of 17α-ethynylestradiol (EE 2 ) induced by high-pressure mercury lamp (λ≥313, 250 W) in aqueous solution of EE 2 was investigated initially. The affecting factors on the photodegradation were studied and described in details, such as EE 2 initial concentration, Fe 3+ , algae, exposure time, and so on. The concentration of EE 2 in distilled water was mainly determined using fluorescence spectrophotometer. The photodegradation of EE 2 in aqueous solution exposed to high-pressure mercury lamp was evident and could be accelerated by Fe 3+ or algae (e.g. Anabaena cylindrica) in general. With the algae concentration increasing, photodegradation rate increased. In this paper, the mechanism of photocatalytic degradation of EE 2 by Fe 3+ or algae is discussed primarily. - Photodegradation increased with increasing concentrations of algae

  15. Determination of the partial pressure of thallium in high-pressure lamp arcs: A comparative study

    International Nuclear Information System (INIS)

    Karabourniotis, D.; Couris, S.; Damelincourt, J.J.; Aubes, M.

    1986-01-01

    The partial pressure of thallium in high-pressure Hg-TlI discharges with different mercury, thallium, and electron pressures has been measured by using the optically thin line Tl 655 nm and the self-reversed line Tl 535 nm. The partial pressure of the arc axis has been measured from the line Tl 655nm. The effective partial pressure has been measured from the self-reversed line Tl 535 nm on the basis of the multiparameter method, and it has been calculated from the known axis pressure of thallium and the calculation of its radial variation by taking into account the chemical reactions. The experimental results confirm the dispersion character of the blue wing of the line Tl 535 nm. The systematic difference obtained between the measured and calculated effective pressure, particularly at the moment of minimum electron density, may be interpreted by deviations from the local thermodynamic equilibrium (LTE) caused by overpopulation of the upper level of the line Tl 535 nm

  16. A compare between myocardial topical negative pressure levels of -25 mmHg and -50 mmHg in a porcine model

    DEFF Research Database (Denmark)

    Lindstedt, Sandra; Paulsson, Per; Mokhtari, Arash

    2008-01-01

    Topical negative pressure (TNP), widely used in wound therapy, is known to stimulate wound edge blood flow, granulation tissue formation, angiogenesis, and revascularization. We have previously shown that application of a TNP of -50 mmHg to the myocardium significantly increases microvascular blo...

  17. Understanding anode and cathode behaviour in high-pressure discharge lamps

    Science.gov (United States)

    Flesch, P.; Neiger, M.

    2005-09-01

    High-intensity discharge (HID) lamps have widespread and modern areas of application including general lighting, video/movie projection (e.g. UHP lamp), street/industrial lighting, and automotive headlight lamps (D2/xenon lamp). Even though HID lamps have been known for several decades now, the important plasma-electrode interactions are still not well understood. Because HID lamps are usually operated on ac (electrodes switch alternately from anode to cathode phase), time-dependent simulations including realistic and verified anode and cathode models are essential. Therefore, a recently published investigation of external laser heating of an electrode during anode and cathode phase in an operating HID lamp [28] provided the basis for our present paper. These measurements revealed impressive influences of the external laser heating on electrode fall voltage and electrode temperature. Fortunately, the effects are very different during anode and cathode phase. Thus, by comparing the experimental findings with results from our numerical simulations we can learn much about the principles of electrode behaviour and explain in detail the differences between anode and cathode phase. Furthermore, we can verify our model (which includes plasma column, hot plasma spots in front of the electrodes, constriction zones and near-electrode non-local thermal equilibrium-plasma as well as anode and cathode) that accounts for all relevant physical processes concerning plasma, electrodes and interactions between them. Moreover, we investigate the influence of two different notions concerning ionization and recombination in the near electrode plasma on the numerical results. This improves our physical understanding of near-electrode plasma likewise and further increases the confidence in the model under consideration. These results are important for the understanding and the further development of HID lamps which, due to their small dimensions, are often experimentally inaccessible

  18. Microwave discharge electrodeless lamps (MDEL). III. A novel tungsten-triggered MDEL device emitting VUV and UVC radiation for use in wastewater treatment.

    Science.gov (United States)

    Horikoshi, Satoshi; Miura, Takashi; Kajitani, Masatsugu; Serpone, Nick

    2008-03-01

    Exposure to low doses of the xenoestrogen bisphenol A (BPA) and to the hormonal 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide, an environmental endocrine disruptor, can have serious health consequences such as the induction of mammary gland ductal hyperplasias and carcinoma (LaChapelle et al., Reprod. Toxicol., 2007, 23, 20; Murray et al., Reprod. Toxicol., 2007, 23, 383). To the extent that these toxins are present in wastewaters (Donald et al., Sci. Total Environ. 1999, 231, 173; Brotons et al., Environ. Health Perspect. 1994, 103, 608; Olea et al., Environ. Health Perspect. 1996, 104, 298; Biles et al., J. Agric. Food Chem. 1997, 45, 3541; Markey et al., J. Steroid Biochem. Mol. Biol., 2003, 83, 235), we examined their oxidative destruction in aqueous media by a novel light source. A tungsten-triggered microwave discharge electrodeless lamp (W-MDEL) was fabricated for possible use in wastewater treatment using vacuum UV-transparent quartz in which a tungsten trigger, also embedded in quartz, was attached to the MDEL to aid in the self-ignition of the lamp on irradiation at low microwave power levels. The quantity of mercury gas in the W-MDEL was optimized by monitoring the continuous radiation and peak intensities of the emitted light in the vacuum UV (VUV) and UVC regions. The usefulness of the W-MDEL device was assessed through the degradation of 2,4-D and BPA in air-equilibrated aqueous media and in oxygen-saturated aqueous media. Enhanced degradation of these two xenoestrogenic toxins was achieved by increasing the number of W-MDEL devices while keeping constant the microwave radiation feeding each W-MDEL lamp. This novel lamp provides an additional light source in the photooxidation of environmental contaminants without the need for a metal-oxide photocatalyst. Under our conditions, process dynamics using the W-MDEL light source are greater than with the more conventional photochemical methods that employ low-pressure Hg arc electrode lamps in synthetic

  19. UV lamp for photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Cardoso, M.J.B.; Landers, R.; Sundaram, V.S.

    1983-01-01

    An UV lamp and a differential pumping system which enables to couple the lamp to an ultra-high vacuum chamber (10 -9 torr) without using windows, are described. The differential between the pressure inside the discharge chamber and the one in de UHV region, which is of 10 8 -10 9 , is achieved with two pumping states separated by pyrex capillaries having an internal diameter of 0.6 mm. In the first stage, a mechanical pump (10 -3 torr) is used; in the second stage, a diffusor pump with a cryogenic trap (N 2 liq - 10 -7 torr) is employed. The lamp produces, when used with high purity He, narrow lines almost clear at 21.2 eV and 40.8 eV, depending on the discharge chamber pressure, thus eliminating the need of a monochromator. As a high voltage source (3 KV), a commercial unit with a good current control was used, ensuring UV beam stability - an essential characteristic for this lamp if it is employed for photoelectron excitation of crystalline samples. (C.L.B.) [pt

  20. Influence of depth of neuromuscular blockade on surgical conditions during low-pressure pneumoperitoneum laparoscopic cholecystectomy: A randomized blinded study.

    Science.gov (United States)

    Barrio, Javier; Errando, Carlos L; García-Ramón, Jaime; Sellés, Rafael; San Miguel, Guillermo; Gallego, Juan

    2017-11-01

    To evaluate the influence of neuromuscular blockade (NMB) on surgical conditions during low-pressure pneumoperitoneum (8mmHg) laparoscopic cholecystectomy (LC), while comparing moderate and deep NMB. Secondary objective was to evaluate if surgical conditions during low-pressure pneumoperitoneum LC performed with deep NMB could be comparable to those provided during standard-pressure pneumoperitoneum (12mmHg) LC. Prospective, randomized, blinded clinical trial. Operating room. Ninety ASA 1-2 patients scheduled for elective LC. Patients were allocated into 3 groups: Group 1: low-pressure pneumoperitoneum with moderate-NMB (1-3 TOF), Group 2: low-pressure pneumoperitoneum with deep-NMB (1-5 PTC) and Group 3: standard pneumoperitoneum (12mmHg). Rocuronium was used to induce NMB and acceleromiography was used for NMB monitoring (TOF-Watch-SX). Three experienced surgeons evaluated surgical conditions using a four-step scale at three time-points: surgical field exposure, dissection of the gallbladder and extraction/closure. Low-pressure pneumoperitoneum (Group 1 vs. 2): good conditions: 96.7 vs. 96.7%, 90 vs. 80% and 89.6 vs. 92.3%, respectively for the time-points, p>0.05. No differences in optimal surgical conditions were observed between the groups. Surgery completion at 8mmHg pneumoperitoneum: 96.7 vs. 86.7%, p=0.353. Standard-pressure pneumoperitoneum vs. low-pressure pneumoperitoneum with deep NMB (Group 3 vs. 2): good conditions: 100% in Group 3 for the three time-points (p=0.024 vs. Group 2 at dissection of the gallbladder). Significantly greater percentage of optimal conditions during standard-pressure pneumoperitoneum LC at the three time points of evaluation. The depth of NMB was found not to be decisive neither in the improvement of surgical conditions nor in the completion of low-pressure pneumoperitoneum LC performed by experienced surgeons. Surgical conditions were considered better with a standard-pressure pneumoperitoneum, regardless of the depth of NMB

  1. Application of a three-dimensional model for a study of the energy transfer of a high-pressure mercury horizontal lamp

    Energy Technology Data Exchange (ETDEWEB)

    Ben Hamida, M. B.; Charrada, K. [Unite d' Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

    2012-06-15

    This paper is devoted to study the dynamics of a discharge lamp with high intensity in a horizontal position. As an example of application, we chose the high-pressure mercury lamp. For this, we realized a three-dimensional model, a stable and powered DC. After the validation of this model, we used it to reproduce the influence of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp operating in a horizontal position. Indeed, the mass of mercury and the electric current are modified and the effect of convective transport is studied.

  2. Investigating antennas as ignition aid for automotive HID lamps

    International Nuclear Information System (INIS)

    Bergner, A; Engelhardt, M; Bienholz, S; Ruhrmann, C; Hoebing, T; Groeger, S; Mentel, J; Awakowicz, P

    2015-01-01

    This paper considers the ignition of mercury-free high-intensity discharge (HID) lamps for car headlights. Due to safety reasons, these lamps need to have a fast run-up phase which is ensured, amongst other things, by a high Xe pressure of roughly 15 bar (cold) in the discharge vessel. The high Xe pressure causes an increased ignition voltage compared with former mercury-containing automotive HID lamps or low-pressure lamps used for general-lighting applications. The increase in ignition voltage can be limited if the electric field in front of the electrodes is raised by an uplifting of the electrical conductivity along the outer wall of the inner bulb either by a conductive layer on its surface or by a dielectric barrier discharge (DBD) within the outer bulb. This paper considers on the one hand conventional antennas deposited by physical vapour deposition (PVD) and on the other hand a combination of these antennas with a DBD within the outer-bulb operated in 100 mbar Ar as ignition aids. In both cases the antenna potential and antenna width are varied. Additionally, the effects of antenna thickness and antenna material are investigated. The ignition voltage, ignition current and light emission during ignition are measured on a nanosecond timescale. Furthermore, for the very first time, the ignition process is recorded in four consecutive intensified charge-coupled device images using a high-speed camera system with a time resolution in the range of nanoseconds. It was found that antennas strongly reduce the ignition voltage of automotive HID lamps. Active antennas reduce the ignition voltage significantly more than passive antennas, proportional to the conductance of the antenna. Combining conventional antennas with an outer-bulb discharge reduces the ignition voltage from 19 kV without any ignition aid to the intrinsic ignition voltage of the lamp below 10 kV, in the best case. (paper)

  3. Metal-halide lamp design: atomic and molecular data needed

    International Nuclear Information System (INIS)

    Lapatovich, Walter P

    2009-01-01

    Metal-halide lamps are a subset of high intensity discharge (HID) lamps so named because of their high radiance. These lamps are low temperature (∼0.5 eV), weakly ionized plasmas sustained in refractory but light transmissive envelopes by the passage of electric current through atomic and molecular vapors. For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-780 nm) to permit the light so generated to render colors comparable to natural sunlight. This is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency (efficacy) and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The electrons, atoms and radicals are in local thermodynamic equilibrium (LTE), but not with the radiation field. Strong thermal (10 6 K m -1 ) and density gradients are sustained in the discharge. Atomic radiation produced in the high-temperature core transits through colder gas regions where it interacts with cold atoms and un-dissociated molecules before exiting the lamp. Power balance and spectral output of the lamp are directly affected by the strength of atomic transitions. Attempts to simulate the radiative output of functional metal-halide lamps have been successful only in very simple cases. More data (e.g. the atomic transition probabilities of Ce i) are necessary to improve lamp performance, to select appropriate radiators and in scaling the lamp geometry to various wattages for specific applications.

  4. Deuterium lamps as transfer standards for spectral radiance measurements

    International Nuclear Information System (INIS)

    Key, P.J.; Nettleton, D.H.

    1985-01-01

    This report describes the work carried out at NPL and PTB to improve the performance of a low pressure deuterium discharge lamp, so that it can be used as a transfer standard in the spectral range 120 to 350 nm. To this end it was necessary: - to replace the original quartz windows by magnesium fluoride single crystal plates, which were cut perpendicular to the c-axis of the crystal and which had to be free of impurities, - to construct the lamps in that way that the directional uniformity of the emitted radiation is within the demands, - to age the lamps and to preselect only those of which the irradiance was stable within ± 1% during a thirty minute period after warm-up, - to improve the commercially available electrical power supply to meet the operational needs of the lamps. Thus, the deuterium lamps drifted by about 3% over a period of 100 h at all wavelengths except at 250 nm, where the ageing increased to 4.5%. A liquid nitrogen trap has been developed which can be installed between the vacuum system and the lamp. This reduced to about 2% the decrease of the window's transmission during the first hour of operation, caused by the deposition of oil from the vacuum system

  5. 46 CFR 53.10-3 - Inspection and tests (modifies HG-500 through HG-540).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Inspection and tests (modifies HG-500 through HG-540... tests (modifies HG-500 through HG-540). (a) The inspections required by HG-500 through HG-540 must be performed by the “Authorized Inspector” as defined in HG-515 of section IV of the ASME Boiler and Pressure...

  6. Comparative analysis of high pressure sodium vapor lamps and mercury vapor lamp with the solid state (LED) in the public lighting systems; Analise comparativa das lampadas de vapor de sodio a alta pressao e de vapor de mercurio com a lampada a estado solido (LED) em sistemas de iluminacao publica

    Energy Technology Data Exchange (ETDEWEB)

    Damato, J.C.; Bueno, J.E.; Astorga, O.A.M. [Universidade Estadual Paulista (LESIP/UNESP), Guaratingueta, SP (Brazil). Lab. de Eficiencia Energetica em Sistemas de Iluminacao Publica; Ricciulli, D.L.S. [Universidade Estadual Paulista (DEE/UNESP), Guaratingueta, SP (Brazil). Dept. de Engenharia Eletrica

    2009-07-01

    The necessity of energy conservation in Brazilian electric sector, with the intention to diminish the resources of generation investments, has going to use of electric energy conservation programs, being most important PROCEL - a national program of electric conservation energy by ELETROBRAS, and inside this, a national program for public illumination and efficient traffic signaling - named 'Reluz'. This program looks for a more efficient implantation of public lighting systems, that requires the use of lamp technologies that present a greater value in a relation between lumen/watt relation and then beyond providing economy, due to low consumption of electric energy. Besides technologies that are appearing, the inclusion of LED lamps, which offers a great application potential, comes blunting as improvement alternative, being that the next public illumination parks will be able count on these lamps associates to the high-pressure sodium lamps and other types currently used. (author)

  7. An ion quencher operated lamp for multiplexed fluorescent bioassays.

    Science.gov (United States)

    Qing, Taiping; Sun, Huanhuan; He, Xiaoxiao; Huang, Xiaoqin; He, Dinggeng; Bu, Hongchang; Qiao, Zhenzhen; Wang, Kemin

    2018-02-01

    A novel and adjustable lamp based on competitive interaction among dsDNA-SYBR Green I (SGI), ion quencher, and analyte was designed for bioanalysis. The "filament" and switch of the lamp could be customized by employing different dsDNA and ion quencher. The poly(AT/TA) dsDNA was successfully screened as the most effective filament of the lamp. Two common ions, Hg 2+ and Fe 3+ , were selected as the model switch, and the corresponding ligand molecules cysteine (Cys) and pyrophosphate ions (PPi) were selected as the targets. When the fluorescence-quenched dsDNA/SGI-ion complex was introduced into a target-containing system, ions could be bound by competitive molecules and separate from the complex, thereby lighting the lamp. However, no light was observed if the biomolecule could not snatch the metal ions from the complex. Under the optimal conditions, sensitive and selective detection of Cys and PPi was achieved by the lamp, with practical applications in fetal bovine serum and human urine. This ion quencher regulated lamp for fluorescent bioassays is simple in design, fast in operation, and is more convenient than other methods. Significantly, as many molecules could form stable complexes with metal ions selectively, this ion quencher operated lamp has potential for the detection of a wide spectrum of analytes. Graphical abstract A novel and adjustable lamp on the basis of competitive interaction among dsDNA-SYBR Green I, ions quencher and analyte was designed for bioanalysis. The filament and switch of lamp could be customized by employing different dsDNA and ions quencher.

  8. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    Science.gov (United States)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  9. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    International Nuclear Information System (INIS)

    De Vos, Marc; Torah, Russel; Tudor, John

    2016-01-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps. (paper)

  10. Demixing in a metal halide lamp, results from modelling

    NARCIS (Netherlands)

    Beks, M.L.; Hartgers, A.; Mullen, van der J.J.A.M.

    2006-01-01

    Convection and diffusion in the discharge region of a metal halide lamp is studied using a computer model built with the plasma modeling package Plasimo. A model lamp contg. mercury and sodium iodide is studied. The effects of the total lamp pressure on the degree of segregation of the light

  11. Appraisal of Bleb Using Trio of Intraocular Pressure, Morphology on Slit Lamp, and Gonioscopy.

    Science.gov (United States)

    Thatte, Shreya; Rana, Rimpi; Gaur, Neeraj

    2016-01-01

    The aim of this study was to assess bleb function using Wuerzburg bleb classification score (WBCS) for bleb morphology on slit lamp, intraocular pressure (IOP), and gonioscopy. A total of randomly selected 30 eyes posttrabeculectomy were assessed for bleb function with the trio of bleb morphology, IOP, and gonioscopy. Bleb was assessed using the WBCS of 0-12 on slit lamp, IOP was assessed using applanation tonometry, and visualization of inner ostium and iridectomy were assessed using gonioscopy. Postoperative patients of less than six weeks were excluded from the study. The correlation between WBCS and the duration of trabeculectomy was found to be highly significant ( P value = 0.029). The correlation of IOP with WBCS was also found to be strongly positive ( P = 0.000). IOP was found to be highly associated with peripheral iridectomy ( P = 0.000), internal window ( P = 0.001), and bleb characteristics.

  12. Apparatus for isotopic alteration of mercury vapor

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Marcucci, Rudolph V.

    1988-01-01

    An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.

  13. High-frequency cold ignition of fluorescent lamps

    International Nuclear Information System (INIS)

    Haverlag, M.; Sormani, J.; Heuvelmans, J.; Geven, A.; Kaldenhoven, L.; Heijne, G.; Kraus, A.

    2002-01-01

    Experimental and theoretical investigations have been performed on the ignition process of low-pressure mercury-noble gas fluorescent lamps operating on a 50 kHz electronic driver circuit. In case the electrodes of the lamp are not heated prior to the ignition process, the ignition process can, under certain conditions, lead to premature fracture of the coiled-coil electrode, which means that the lamp ceases to operate before the emitter is consumed completely. Experimental studies of this process have shown that the erosion process responsible for this premature end-of-life consists of localized sputtering of the tungsten electrode by energetic ions from the glow discharge that is present during the ignition process. In order to understand the basic process that leads to localized sputtering of the electrodes in a glow discharge, a simple glow-discharge fluid model, in combination with a finite-element model of the heat transport in the electrode, has been built. The model shows that thermionic emission can supply a significant fraction of the electrons already at temperatures far below the normal operating temperature in fluorescent lamps. This thermionic emission is responsible for a contraction process. After the beginning of the discharge contraction it takes typically a few milliseconds before the glow-to-arc transition is observed in the lamp voltage and the normal electrode operating temperature is reached. During this time localized sputtering takes place, which eventually leads to coil fracture. (author)

  14. Note: implementation of a cold spot setup for controlled variation of vapor pressures and its application to an InBr containing discharge lamp.

    Science.gov (United States)

    Briefi, S

    2013-02-01

    In order to allow for a systematic investigation of the plasma properties of discharges containing indium halides, which are proposed as an efficient alternative for mercury based low pressure discharge lamps, a controlled variation of the indium halide density is mandatory. This can be achieved by applying a newly designed setup in which a well-defined cold spot location is implemented and the cold spot temperature can be adjusted between 50 and 350 °C without influencing the gas temperature. The performance of the setup has been proved by comparing the calculated evaporated InBr density (using the vapor pressure curve) with the one measured via white light absorption spectroscopy.

  15. Design and development of low-power driven hybrid electroluminescent lamp from carbon nanotube embedded phosphor material

    International Nuclear Information System (INIS)

    Yadav, Deepika; Mishra, Savvi; Shanker, Virendra; Haranath, D.

    2013-01-01

    Highlights: •We are first to report CNT embedded ZnS:Mn hybrid EL system. •Achieved efficient orange-red EL emission at low operating voltages ( AC ). •Facile technique to induce conductive paths inside the ZnS particle to trigger EL. •Detailed electrical characterization of EL lamp is presented. -- Abstract: We present a novel methodology to design a hybrid electroluminescent (EL) lamp by embedding carbon nanotubes (CNTs) inside the ZnS:Mn phosphor particles by conventional solid state diffusion technique. By doing so, the phosphor particles exhibited increase in EL brightness and efficiency at low operating voltages ( AC ). Interestingly, shorter the length of CNTs used, greater was the field enhancement effect and lower was the operating voltages to glow the EL lamps. The role of CNTs have been identified to form conductive paths inside the ZnS particle thereby triggering EL due to electron injection to luminescent centers (Mn 2+ ) at nominal voltages. In addition, a detailed electrical characterization of the novel EL lamp along with its spectral energy distribution studies are presented

  16. 21 CFR 1040.30 - High-intensity mercury vapor discharge lamps.

    Science.gov (United States)

    2010-04-01

    ... use. (4) Outer envelope means the lamp element, usually glass, surrounding a high-pressure arc... than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will... unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish...

  17. RF Noise Generation in High-Pressure Short-Arc DC Xenon Lamps

    Science.gov (United States)

    Minayeva, Olga; Doughty, Douglas

    2007-10-01

    Continuous direct current xenon arcs will generate RF noise under certain circumstance, which can lead to excessive electro- magnetic interference in systems that use these arcs as light sources. Phenomenological observations are presented for xenon arcs having arc gaps ˜1 mm, cold fill pressures of ˜2.5 MPa, and currents up to 30 amps. Using a loop antenna in the vicinity of an operating lamp, it is observed that as the current to the arc is lowered there is a reproducible threshold at which the RF noise generation begins. This threshold is accompanied by a small abrupt drop in voltage (˜0.2 volts). The RF emission appears in pulses ˜150 nsec wide separated by ˜300 nec - the pulse interval decreases with decreasing current. The properties of the RF emission as a function of arc parameters (such as pressure, arc gap, electrode design) will be discussed and a semi-quantitative model presented.

  18. Global Burden of Hypertension and Systolic Blood Pressure of at Least 110 to 115 mm Hg, 1990-2015

    DEFF Research Database (Denmark)

    Forouzanfar, Mohammad H; Liu, Patrick; Roth, Gregory A

    2017-01-01

    Importance: Elevated systolic blood (SBP) pressure is a leading global health risk. Quantifying the levels of SBP is important to guide prevention policies and interventions. Objective: To estimate the association between SBP of at least 110 to 115 mm Hg and SBP of 140 mm Hg or higher and the bur......Importance: Elevated systolic blood (SBP) pressure is a leading global health risk. Quantifying the levels of SBP is important to guide prevention policies and interventions. Objective: To estimate the association between SBP of at least 110 to 115 mm Hg and SBP of 140 mm Hg or higher...... and the burden of different causes of death and disability by age and sex for 195 countries and territories, 1990-2015. Design: A comparative risk assessment of health loss related to SBP. Estimated distribution of SBP was based on 844 studies from 154 countries (published 1980-2015) of 8.69 million participants...... in the primary analysis. Main Outcomes and Measures: Mean SBP level, cause-specific deaths, and health burden related to SBP (≥110-115 mm Hg and also ≥140 mm Hg) by age, sex, country, and year. Results: Between 1990-2015, the rate of SBP of at least 110 to 115 mm Hg increased from 73 119 (95% uncertainty...

  19. Ocular onchocerciasis in the Yanomami communities from Brazilian Amazon: effects on intraocular pressure.

    Science.gov (United States)

    Herzog-Neto, Guilherme; Jaegger, Karen; Nascimento, Erika S do; Marchon-Silva, Verônica; Banic, Dalma M; Maia-Herzog, Marilza

    2014-01-01

    To determine the influence of onchocercal eye disease on the intraocular pressure of the Yanomami Tribe Aratha-ú of Roraima State, Brazil, considered endemic for onchocerciasis, a total of 86 patients were submitted to an ophthalmologic exam that included external examination, slit lamp examination, intraocular pressure measurement, and a fundus ophthalmoscope examination. A high prevalence of onchocerciasis-related eye lesions was encountered in 68.6% of the patients. Punctate keratitis and microfilariae in the anterior chamber were found in ∼28%. The mean of intraocular eye pressure found was 10.47 mm of Hg.

  20. LASER-INDUCED BREAKDOWN SPECTROSCOPY AND ...

    African Journals Online (AJOL)

    B. S. Chandravanshi

    has led to the development and continuous improvement of various analytical methods. These .... provided by a Milli-Q water purification system (Simplicity UV, France). ... Wavelength calibration was conducted with a low pressure Hg-Ar lamp.

  1. Using MOF-74 for Hg2+ removal from ultra-low concentration aqueous solution

    International Nuclear Information System (INIS)

    Xiong, Yang Yang; Li, Jian Qiang; Gong, Le Le; Feng, Xue Feng; Meng, Li Na; Zhang, Le; Meng, Pan Pan; Luo, Ming Biao; Luo, Feng

    2017-01-01

    Mercury (Hg 2+ ) ions have very high toxicity and widely spread as environmental pollutants. At present, many efforts have been taken to remove the hazardous materials of mercury(II) by adsorption, and it is highly desirable to develop a novel adsorbent with high adsorptive capacities. However it is still a big challenge to remove the ultra-low-concentration mercury ions from water. In this paper, MOF-74-Zn is explored for such function, showing high removal rate of Hg(II) from water without any pretreatment, especially for the ultra-trace Hg(II) ions in the ppb magnitude with the removal rate reaching to 54.48%, 69.71%, 72.26% when the initial concentration of Hg(II) is 20ppb, 40ppb, 50ppb, respectively. - Graphical abstract: The absorption of mercury ions on MOF-74-Zn is due to somewhat weak interactions between MOF skeleton that is composed of carboxylate and hydroxy group and Hg2+ ions. - Highlights: • MOF-74-Zn shows high removal rate of Hg(II) from water without any pretreatment. • The MOF-74-Zn has a notable performance at ultra-low concentration of Hg(II). • MOF-74-Zn shows the potential for Hg(II) removal from industrial waste water.

  2. The instantaneous light-intensity function of a fluorescent lamp

    Energy Technology Data Exchange (ETDEWEB)

    Gluskin, Emanuel [Holon Institute of Technology, 52 Golomb St., Holon 58102 (Israel): Electrical Engineering Department, Ben-Gurion University, Beer-Sheva 84105 (Israel)]. E-mail: gluskin@ee.bgu.ac.il; Topalis, Frangiskos V. [Technical University of Athens, School of Electrical and Computer Engineering, 9 Iroon Politechniou St., 15780 Athens (Greece); Kateri, Ifigenia [Technical University of Athens, School of Electrical and Computer Engineering, 9 Iroon Politechniou St., 15780 Athens (Greece); Bisketzis, Nikolas [Technical University of Athens, School of Electrical and Computer Engineering, 9 Iroon Politechniou St., 15780 Athens (Greece)

    2006-05-08

    Using some simple physics and 'system' considerations, the instantaneous light intensity function {psi}(t) of a fluorescent lamp fed via a regular ballast from the 50-60 Hz line is argued to be {psi}(t)={psi}{sub min}+bp(t), where p(t) is the instantaneous power function of the lamp, and b is a constant, and experiment confirms this formula well. The main frequency of {psi}(t), the very significant singularity of its waveform, and the relative intensity of the ripple, i.e., the depth of the modulation, are the focus. The results are important for research into the vision problem that some humans (autistic, but others, too) experience regarding fluorescent light. The inertia of the processes in the lamp which are responsible for the light emission, provides some nonzero emission at the instants when p(t) has zeros. The smaller the volume of the tube and the mass of the gas are, the more weakly the inertia of the processes is expressed, and the relatively smaller is {psi}{sub min}. However, it should be very difficult to theoretically obtain {psi}(t), in particular {psi}{sub min}, from the very complicated physics of the low-pressure discharge in the tube. We conclude that {psi}{sub min} has to be connected with the (also easily measured) lamp's inductance. The work should attract more attention of the physicists to the properties of the common fluorescent lamps. escent lamps.

  3. Influence of electrode, buffer gas and control gear on metal halide lamp performance

    International Nuclear Information System (INIS)

    Lamouri, A; Naruka, A; Sulcs, J; Varanasi, C V; Brumleve, T R

    2005-01-01

    In this paper the influence of electrode composition, buffer gas fill pressure and control gear on the performance of metal halide lamps is investigated. It is shown that pure tungsten electrodes improve lumen maintenance and reduce voltage rise over lamp life. An optimum buffer gas fill pressure condition is discovered which allows for reduced electrode erosion during lamp starting as well as under normal operating conditions. Use of electronic control gear is shown to improve the performance of metal halide lamps

  4. Hg(+) Frequency Standards

    Science.gov (United States)

    Prestage, John D.; Tjoelker, Robert L.; Maleki, Lute

    2000-01-01

    In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

  5. Effect of Cooking on Speciation and In Vitro Bioaccessibility of Hg and As from Rice, Using Ordinary and Pressure Cookers.

    Science.gov (United States)

    Liao, Wen; Wang, Guang; Li, Kaiming; Zhao, Wenbo; Wu, Ye

    2018-05-03

    Rice is the most widely consumed staple food for a large part of the world's human population, and owing to environmental pollution, it is a major source of human exposure to mercury (Hg) and arsenic (As). We evaluated the impact of cooking on the speciation and bioaccessibility of Hg and As from rice in this study. Results show that the dominant Hg and As species in rice from Guangzhou market in China were their inorganic forms (iHg and iAs), respectively. The cooking process modified the levels of Hg and As. Average Hg and As bioaccessibility in raw rice was 69.74 and 80.32%, respectively. Hg bioaccessibility decreased to 46.22 and 42.37% for pressure- and ordinary-cooked rice, respectively. In contrast, As bioaccessibility remained unchanged except after cooking with a large amount of water. Protein denaturation and the amount of soluble and volatile forms determine the bioaccessibility of Hg and As in cooked rice by being released into the cooking water or into the air. From the bioaccessibility data, the average established daily intake (EDI) values of Hg and As from pressure-cooked rice for children and adults were 0.034 and 0.025 μg kg -1  day -1 (Hg), and 0.735 and 0.559 μg kg -1  day -1 (As), respectively. This study provides novel insights into Hg and As exposure due to rice cooking.

  6. Post-treatment of refinery wastewater effluent using a combination of AOPs (H2O2 photolysis and catalytic wet peroxide oxidation) for possible water reuse. Comparison of low and medium pressure lamp performance.

    Science.gov (United States)

    Rueda-Márquez, J J; Levchuk, I; Salcedo, I; Acevedo-Merino, A; Manzano, M A

    2016-03-15

    The main aim of this work was to study the feasibility of multi-barrier treatment (MBT) consisting of filtration, hydrogen peroxide photolysis (H2O2/UVC) and catalytic wet peroxide oxidation (CWPO) for post-treatment of petroleum refinery effluent. Also the possibility of water reuse or safe discharge was considered. The performance of MBT using medium (MP) and low (LP) pressure lamps was compared as well as operation and maintenance (O&M) cost. Decomposition of organic compounds was followed by means of gas chromatography-mass spectrometry (GC-MS), total organic carbon (TOC) and chemical oxygen demand (COD) analysis. After filtration step (25 μm) turbidity and concentration of suspended solids decreased by 92% and 80%, respectively. During H2O2/UVC process with LP lamp at optimal conditions (H2O2:TOC ratio 8 and UVC dose received by water 5.28 WUVC s cm(-2)) removal of phenolic compounds, TOC and COD was 100%, 52.3% and 84.3%, respectively. Complete elimination of phenolic compounds, 47.6% of TOC and 91% of COD was achieved during H2O2/UVC process with MP lamp at optimal conditions (H2O2:TOC ratio 5, UVC dose received by water 6.57 WUVC s cm(-2)). In order to compare performance of H2O2/UVC treatment with different experimental set up, the UVC dose required for removal of mg L(-1) of COD was suggested as a parameter and successfully applied. The hydrophilicity of H2O2/UVC effluent significantly increased which in turn enhanced the oxidation of organic compounds during CWPO step. After H2O2/UVC treatment with LP and MP lamps residual H2O2 concentration was 160 mg L(-1) and 96.5 mg L(-1), respectively. Remaining H2O2 was fully consumed during subsequent CWPO step (6 and 3.5 min of contact time for LP and MP, respectively). Total TOC and COD removal after MBT was 94.7% and 92.2% (using LP lamp) and 89.6% and 95%, (using MP lamp), respectively. The O&M cost for MBT with LP lamp was estimated to be 0.44 € m(-3) while with MP lamp it was nearly five

  7. Hydrostatic pressure dependence of the superconducting transition temperature of HgBa2CaCu2O6+δ and HgBa2Ca2Cu3O8+δ

    International Nuclear Information System (INIS)

    Klehe, A.K.; Schilling, J.S.

    1994-02-01

    The dependence of the superconducting transition temperature T c (P) on purely hydrostatic pressure to 0.9 GPa has been determined in ac susceptibility studies in a He-gas pressure system for optimally doped ceramic samples of HgBa 2 CaCu 2 O 6+δ and HgBa 2 Ca 2 Cu 3 O 8+δ with superconducting transitions at T c (0) ≅ 126.6 K and 133.9 K, respectively. T c increases reversibly under hydrostatic pressure at the rates, d T c /dP ≅ +1.80 ± 0.06 K/GPa and +1.71 ± 0.05 K/GPa, respectively. Within experimental error, these values are the same as found previously for optimally doped single-layered HgBa 2 CuO 4+δ , where d T c /dP ≅ +1.72 ± 0.05 K/GPa. Remarkably, the logarithmic volume derivative of T c is nearly identical for all three compounds, dln T c /dlnV ≅ -1.20 ± 0.05, even though the bulk modulus differs by more than 30%. This provides strong evidence that a common mechanism is responsible for the pressure dependence of the superconducting state in all three compounds

  8. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  9. Vapour pressure of components made by the presence of HgS(s,alpha) in an oil/gas reservoir and consequences for the produced gas

    Energy Technology Data Exchange (ETDEWEB)

    Oestvold, T.; Gustavsen, Oe.; Grande, K.; Aas, N.; Olsvik, Mimmi Kjetsaa

    2006-03-15

    A thermodynamic analysis is presented on how components made from HgS (s,alpha), existing in a oil/gas reservoir, will distribute themselves between gas, water, liquid and solid components as a function of temperature and pressure. The consequence of the formation of mercury containing components on gas injection and on gas quality is discussed. Since equilibrium is established in the model calculation, other gas components in the gas phase and components in condensed phases present will also influence the composition of the gas. Six cases are considered in the calculation: 1) HgS(s,alpha) - Ar(g), 2) HgS(s,alpha) - Ar (g) - water with 10-4 molal NaCl at pH = 7, 3) HgS(s,alpha) - CH{sub 4}(g), 4) HgS(s,alpha) - CH{sub 4} (g) - water with 10-4 molal NaCl at pH = 7 and 5) HgS(s,alpha) - natural gas - water with 10-4 molal NaCl at pH = 7, 6) HgS(s,alpha) - natural gas - water with 10-4 molal NaCl and 5*10-5 molal NO-3- at pH = 7. When HgS(s,alpha) is present in an oil reservoir at 170 deg C and 200 bar, these calculations show that the major components formed are: H{sub 2}(g), H{sub 2}S(g), Hg(l) and Hg(g) together with carbon. Mercury in the gas phase in the cases 1) is 4*10-7 bar and is determined by the evaporation and decomposition HgS(g) in the reservoir. In case 2) P{sub Hg} = 5.7*10-4 bar mainly determined by the formation of sulphate in the water phase. In the cases 3), 4) and 5) these calculations show that the major components formed are: H{sub 2}(g), H{sub 2}S(g), Hg(l) and Hg(g) together with carbon, and the gas phase is dominated by Hg(g) at approx. *10-3 bar. The water phase may contain Hg(CH{sub 3}NH{sub 2}){sub 2}2+ if NO{sub 3}- for some reasons is introduced into the formation water, and the very carcinogenic dimethyl mercury compound, C{sub 2}HgH{sub 6}, can be formed in the gas phase. Both compounds, however, in insignificant low concentration/partial pressure. (Author)

  10. X-ray absorption tomography of a high-pressure metal-halide lamp with a bent arc due to Lorentz-forces

    NARCIS (Netherlands)

    Denisova, N.; Haverlag, M.; Ridderhof, E.J.; Nimalasuriya, T.; Mullen, van der J.J.A.M.

    2007-01-01

    The arc temperature is one of the most important characteristics which cotrol the emission properties of plasma light sources. X-ray absorption technique has received some attention as a powerful method to determine the temperature in high-pressure metal-halide lamps. An important advantage of x-ray

  11. Using MOF-74 for Hg{sup 2+} removal from ultra-low concentration aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Yang Yang; Li, Jian Qiang; Gong, Le Le; Feng, Xue Feng; Meng, Li Na; Zhang, Le; Meng, Pan Pan; Luo, Ming Biao; Luo, Feng, E-mail: ecitluofeng@163.com

    2017-02-15

    Mercury (Hg{sup 2+}) ions have very high toxicity and widely spread as environmental pollutants. At present, many efforts have been taken to remove the hazardous materials of mercury(II) by adsorption, and it is highly desirable to develop a novel adsorbent with high adsorptive capacities. However it is still a big challenge to remove the ultra-low-concentration mercury ions from water. In this paper, MOF-74-Zn is explored for such function, showing high removal rate of Hg(II) from water without any pretreatment, especially for the ultra-trace Hg(II) ions in the ppb magnitude with the removal rate reaching to 54.48%, 69.71%, 72.26% when the initial concentration of Hg(II) is 20ppb, 40ppb, 50ppb, respectively. - Graphical abstract: The absorption of mercury ions on MOF-74-Zn is due to somewhat weak interactions between MOF skeleton that is composed of carboxylate and hydroxy group and Hg2+ ions. - Highlights: • MOF-74-Zn shows high removal rate of Hg(II) from water without any pretreatment. • The MOF-74-Zn has a notable performance at ultra-low concentration of Hg(II). • MOF-74-Zn shows the potential for Hg(II) removal from industrial waste water.

  12. Filter for isotopic alteration of mercury vapor

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1989-01-01

    A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.

  13. Numerical study on xenon positive column discharges of mercury-free lamp

    International Nuclear Information System (INIS)

    Ouyang, Jiting; He, Feng; Miao, Jinsong; Wang, Jianqi; Hu, Wenbo

    2007-01-01

    In this paper, the numerical study has been performed on the xenon positive column discharges of mercury-free fluorescent lamp. The plasma discharge characteristics are analyzed by numerical simulation based on two-dimensional fluid model. The effects of cell geometry, such as the dielectric layer, the electrode width, the electrode gap, and the cell height, and the filling gas including the pressure and the xenon percentage are investigated in terms of discharge current and discharge efficiency. The results show that a long transient positive column will form in the xenon lamp when applying ac sinusoidal power and the lamp can operate in a large range of voltage and frequency. The front dielectric layer of the cell plays an important role in the xenon lamp while the back layer has little effect. The ratio of electrode gap to cell height should be large to achieve a long positive column xenon lamp and higher efficiency. Increase of pressure or xenon concentration results in an increase of discharge efficiency and voltage. The discussions will be helpful for the design of commercial xenon lamp cells

  14. Human exposure to mercury in a compact fluorescent lamp manufacturing area: By food (rice and fish) consumption and occupational exposure

    International Nuclear Information System (INIS)

    Liang, Peng; Feng, Xinbin; Zhang, Chan; Zhang, Jin; Cao, Yucheng; You, Qiongzhi; Leung, Anna Oi Wah; Wong, Ming-Hung; Wu, Sheng-Chun

    2015-01-01

    To investigate human Hg exposure by food consumption and occupation exposure in a compact fluorescent lamp (CFL) manufacturing area, human hair and rice samples were collected from Gaohong town, Zhejiang Province, China. The mean values of total mercury (THg) and methylmercury (MeHg) concentrations in local cultivated rice samples were significantly higher than in commercial rice samples which indicated that CFL manufacturing activities resulted in Hg accumulation in local rice samples. For all of the study participants, significantly higher THg concentrations in human hair were observed in CFL workers compared with other residents. In comparison, MeHg concentrations in human hair of residents whose diet consisted of local cultivated rice were significantly higher than those who consumed commercial rice. These results demonstrated that CFL manufacturing activities resulted in THg accumulation in the hair of CFL workers. However, MeHg in hair were mainly affected by the sources of rice of the residents. - Highlights: • Rice samples were contaminated by Compact fluorescent lamp (CFL) manufacturing. • CFL manufacturing lead to THg accumulation in human hair. • MeHg in human hair were mainly affected by the sources of rice. • MeHg intake from fish consumption was lower than that from rice consumption. • PDI of MeHg by food consumption was below the guidelines for public health concern. - CFL manufacturing activities result in Hg accumulation in local rice samples and hair of CFL workers. However, MeHg in hair were mainly affected by sources of rice

  15. Investigation of acoustic resonances in high-power lamps

    International Nuclear Information System (INIS)

    Kettlitz, M; Zalach, J; Rarbach, J

    2011-01-01

    High-power, medium-pressure, mercury-containing lamps are used as UV sources for many industrial applications. Lamps investigated in this paper are driven with an electronic ballast with a non-sinusoidal current waveform at a fixed frequency of 20 kHz and a maximum power output of 35 kW. Instabilities can occur if the input power is reduced below 50%. The reason is identified as acoustic resonances in the lamp. Comparison of calculated and measured resonance frequencies shows a good agreement and explains the observed lamp behaviour. This has led to the development of a new ballast prototype which is able to avoid instabilities by changing the driving frequency dependent on the applied power.

  16. Demixing in a metal halide lamp, results from modeling

    NARCIS (Netherlands)

    Beks, M.L.; Hartgers, A.; Mullen, van der J.J.A.M.; Veldhuizen, van E.M.

    2005-01-01

    Metal Halide (MH) lamps are high pressure discharge devices, containing a complex chemical mixture, to emit light on a broad spectrum while maintaining good efficacies. Lamps of this type were first exhibited by General Electric at the 1964 World Fair in New York [1]. They typically consist of an

  17. Optimized elemental analysis of fluorescence lamp shredder waste.

    Science.gov (United States)

    Hobohm, Julia; Kuchta, Kerstin; Krüger, Oliver; van Wasen, Sebastian; Adam, Christian

    2016-01-15

    Fluorescence lamps contain considerable amounts of rare earth elements (REE). Several recycling procedures for REE recovery from spent lamps have been established. However, despite their economic importance, the respective recycling is scarce so far, with an REE recovery rate of less than 1%. A reliable analysis of REE and other relevant metals like Yttrium is crucial for a thorough and complete recovery process. This applies both to the solid matter and aqueous phase, since most of the recycling processes include wet-chemical steps. We tested seven different reagent mixtures for microwave-assisted digestion of fluorescent lamp shredder, including hydrofluoric acid, perchloric acid, and hydrogen peroxide. We determined the concentrations of 25 of the most relevant rare earth and other trace elements (Al, P, Ti, V, Cr, Fe, Ni, Cu, Ga, Ge, As, Y, Ag, Cd, Sn, Sb, La, Ce, Eu, Gd, Tb, W, Au, Hg, and Pb) in the respective dilutions. Two independent digestions, one a mixture of perchlorid/nitric/hydrofluoric acid and the other aqua regia, showed the highest concentrations of 23 of these elements, excluding only Sn and Tb. The REE concentrations in the tested lamp shredder sample (stated in g/kg) were 10.2 (Y), 12.1 (La), 7.77 (Ce), 6.91 (Eu), 1.90 (Gd), and 4.11 (Tb). Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  19. Protonation enhancement by dichloromethane doping in low-pressure photoionization.

    Science.gov (United States)

    Shu, Jinian; Zou, Yao; Xu, Ce; Li, Zhen; Sun, Wanqi; Yang, Bo; Zhang, Haixu; Zhang, Peng; Ma, Pengkun

    2016-12-01

    Doping has been used to enhance the ionization efficiency of analytes in atmospheric pressure photoionization, which is based on charge exchange. Compounds with excellent ionization efficiencies are usually chosen as dopants. In this paper, we report a new phenomenon observed in low-pressure photoionization: Protonation enhancement by dichloromethane (CH 2 Cl 2 ) doping. CH 2 Cl 2 is not a common dopant due to its high ionization energy (11.33 eV). The low-pressure photoionization source was built using a krypton VUV lamp that emits photons with energies of 10.0 and 10.6 eV and was operated at ~500-1000 Pa. Protonation of water, methanol, ethanol, and acetaldehyde was respectively enhanced by 481.7 ± 122.4, 197.8 ± 18.8, 87.3 ± 7.8, and 93.5 ± 35.5 times after doping 291 ppmv CH 2 Cl 2 , meanwhile CH 2 Cl 2 almost does not generate noticeable ions itself. This phenomenon has not been documented in the literature. A new protonation process involving in ion-pair and H-bond formations was proposed to expound the phenomenon. The observed phenomenon opens a new prospect for the improvement of the detection efficiency of VUV photoionization.

  20. The Role of Low-frequency TRANS-orbital Magnetic Stimulation in Normalization of Intraocular Pressure in Patients with Primary Open-angle Glaucoma

    Directory of Open Access Journals (Sweden)

    I. A. Makarov

    2016-01-01

    Full Text Available Purpose. Assessment of the effectiveness of low-frequency magnetic therapy on the dynamics of intraocular pressure in the treatment of primary and uncompensated medical means of open-angle glaucoma. Patients and Methods. 46 patients with uncompensated open-angle glaucoma. The first group: 24 patients (42 eyes with open-angle glaucoma (I, II, III stages during 2–13 years. The second group: 22 patients (22 eyes with newly diagnosed elevated intraocular pressure in one eye. The age of patients ranged from 43 to 59 years. Treatment included antiglaucoma hypotensive eye drops and TRANS-orbital magnetic stimulation on the domestic device“Polus-2”. Results. Intraocular pressure before treatment ranged from 25 to 32 mm Hg. (average of 28.9±1.4 mm Hg. in the first group . After magnetic stimulation IOP decreased within 2–5 days in all patients to 18 to 21 mm Hg (average of 17.9±1.1 mm Hg, reaching values “pressure goal.” Second group: in the primary treatment in patients IOP was 28–39 mm Hg (average of 32.6±1.8 mm Hg on one of the eyes. IOP decreased to 16–21 mm Hg in the period from 3 to 9 days in all patients of study group after daily magnetic stimulation and instillation of xalatan and timolol. In the control subgroup of patients with uncompensated openangle glaucoma loweringof the IOP to “pressure goal,” noted only in 7 patients (70,0% 11–14 days after instillation of anti-hypertensive glaucoma eye drops only. Conclusion. Low-frequency TRANS-orbital magnetic stimulation in enhanced hypotensive effect antiglaucomatous eye drops and makes it easier to achieve compensation of IOP to values “pressure goals” in patients with uncompensated open-angle glaucoma. The marked dependence of the efficiency of reduction of IOP from biotropic parameters of the magnetic field. The pulsed mode with a higher amplitude value of the magnetic induction has a more pronounced effect and makes it easier to achieve the reduction of IOP.

  1. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Safety valve requirements for steam boilers (modifies HG-400 and HG-401). 53.05-1 Section 53.05-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... requirements for steam boilers (modifies HG-400 and HG-401). (a) The pressure relief valve requirements and the...

  2. Chemical stabilization and high pressure synthesis of Ba-free Hg-based superconductors, (Hg,M)Sr{sub 2}Ca{sub n-1}Cu{sub n}O{sub y}(N=1{approximately}3)

    Energy Technology Data Exchange (ETDEWEB)

    Kishio, K. [Univ. of Tokyo (Japan)]|[Kyoto Univ. (Japan); Shimoyama, J.; Hahakura, S. [Univ. of Tokyo (Japan)] [and others

    1994-12-31

    A homologous series of new Hg-based HTSC compounds, (Hg,M)Sr{sub 2}Ca{sub n-1}Cu{sub n}O{sub y} with n=1 to 3, have been synthesized. The stabilization of the pure phases have been accomplished by chemical doping of third elements such as M=Cr, Mo and Re. While the Hg1201(n=1) phase was readily obtained in this way, it was necessary to simultaneously dope Y into the Ca site to stabilize the Hg1212(n=2) phase. On the other hand, single-phase Y-free Hg1212(n=2) and Hg1223(n=3) samples were synthesized only under a high pressure of 6 GPa. In sharp contrast to the Ba-containing compounds, all the samples prepared in the present study have been quite stable during the synthesis and no deterioration in air has been observed after the preparation.

  3. UHP lamp systems for projection applications

    International Nuclear Information System (INIS)

    Derra, Guenther; Moench, Holger; Fischer, Ernst; Giese, Hermann; Hechtfischer, Ulrich; Heusler, Gero; Koerber, Achim; Niemann, Ulrich; Noertemann, Folke-Charlotte; Pekarski, Pavel; Pollmann-Retsch, Jens; Ritz, Arnd; Weichmann, Ulrich

    2005-01-01

    Projection systems have found widespread use in conference rooms and other professional applications during the last decade and are now entering the home TV market at a considerable pace. Projectors as small as about one litre are able to deliver several thousand screen lumens and are, with a system efficacy of over 10 lm W -1 , the most efficient display systems realized today. Short arc lamps are a key component for projection systems of the highest efficiency for small-size projection displays. The introduction of the ultra high performance (UHP) lamp system by Philips in 1995 can be identified as one of the key enablers of the commercial success of projection systems. The UHP lamp concept features outstanding arc luminance, a well suited spectrum, long life and excellent lumen maintenance. For the first time it combines a very high pressure mercury discharge lamp with extremely short and stable arc gap with a regenerative chemical cycle keeping the discharge walls free from blackening, leading to lifetimes of over 10 000 h. Since the introduction of the UHP lamp system, many important new technology improvements have been realized: burner designs for higher lamp power, advanced ignition systems, miniaturized electronic drivers and innovative reflector concepts. These achievements enabled the impressive increase of projector light output, a remarkable reduction in projector size and even higher optical efficiency in projection systems during the last years. In this paper the concept of the UHP lamp system is described, followed by a discussion of the technological evolution the UHP lamp has undergone so far. Last, but not least, the important improvements of the UHP lamp system including the electronic driver and the reflector are discussed. (review article)

  4. A gas discharge lamp for the extreme ultraviolet.

    Science.gov (United States)

    Nicholson, A J

    1970-05-01

    A gas discharge lamp is described suitable for producing the many-lined spectrum of hydrogen (85-160 nm) and the Hopfield continuum in helium (60-100 nm). It was designed for use with a window-less monochromator to study photoionization and operates at pressures below 50 Torr. The hydrogen lamp has a mode of operation which concentrates the discharge into the monochromator entrance slit.

  5. Joint Association of Low Vitamin D and Vitamin K Status With Blood Pressure and Hypertension.

    Science.gov (United States)

    van Ballegooijen, Adriana J; Cepelis, Aivaras; Visser, Marjolein; Brouwer, Ingeborg A; van Schoor, Natasja M; Beulens, Joline W

    2017-06-01

    Low vitamin D and K status are both associated with an increased cardiovascular risk. New evidence from experimental studies on bone health suggest an interaction between vitamin D and K; however, a joint association with vascular health outcomes is largely unknown. To prospectively investigate whether the combination of low vitamin D and K status is associated with higher systolic and diastolic blood pressure in 402 participants and with incident hypertension in 231 participants free of hypertension at baseline. We used data from a subsample of the Longitudinal Aging Study Amsterdam, a population-based cohort of Dutch participants aged 55 to 65 years. Vitamin D and K status were assessed by 25-hydroxyvitamin D and dp-ucMGP (dephosphorylated uncarboxylated matrix gla protein) concentrations (high dp-ucMGP is indicative for low vitamin K status) in stored samples from 2002 to 2003. Vitamin D and K status were categorized into 25-hydroxyvitamin D hypertension. The combination of low vitamin D and K status was associated with increased systolic 4.8 mm Hg (95% confidence interval, 0.1-9.5) and diastolic 3.1 mm Hg (95% confidence interval, 0.5-5.7) blood pressure compared with high vitamin D and K status ( P for interaction =0.013 for systolic blood pressure and 0.068 for diastolic blood pressure). A similar trend was seen for incident hypertension: hazard ratio=1.62 (95% confidence interval, 0.96-2.73) for the low vitamin D and K group. The combination of low vitamin D and K status was associated with increased blood pressure and a trend for greater hypertension risk. © 2017 American Heart Association, Inc.

  6. Circular, explosion-proof lamp provides uniform illumination

    Science.gov (United States)

    1966-01-01

    Circular explosion-proof fluorescent lamp is fitted around a TV camera lens to provide shadowless illumination with a low radiant heat flux. The lamp is mounted in a transparent acrylic housing sealed with clear silicone rubber.

  7. Investigating the outer-bulb discharge as ignition aid for automotive-HID lamps

    International Nuclear Information System (INIS)

    Bergner, A; Groeger, S; Hoebing, T; Ruhrmann, C; Mentel, J; Awakowicz, P; Hechtfischer, U; Tochadse, G

    2014-01-01

    This work considers the ignition process of mercury-free high-intensity discharge lamps used for car headlights. These lamps have to run-up fast. This is achieved with a high xenon pressure of about 15 bar (cold) in the inner bulb. The high filling-gas pressure causes an increased ignition voltage compared with lower-pressure lamps used in general-lighting applications. In this paper the possibility is investigated to reduce the ignition voltage by optimizing a dielectric-barrier discharge (DBD) in the outer bulb working as ignition aid. A special outer bulb was built up allowing gas exchange and adjustment of the gas pressure. For diagnostic purposes different electrical and optical methods are used, namely the recording of ignition voltage, ignition current and light emission by a photo-diode signal on nanosecond time scale as well as short-time photography by a intensified charge-coupled device camera. It was found that the DBD mainly generates a potential distribution within the lamp which supports ignition by an increase in the E-field in front of the electrodes and the wall. It is shown that this effect is distinctly more effective than UV radiation potentially emitted by the DBD. (paper)

  8. Study of the cathode region of mercury-free He-Xe low-pressure gas-discharge lamps with planar mesh electrode; Untersuchung der Kathodenregion von quecksilberfreien He-Xe Niederdruckgasentladungslampen mit planarer Geflechtelektrode

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Joern

    2009-12-04

    In the present work the cathode region of a mercury-free helium-xenon low pressure discharge in spot mode was experimentally investigated. Due to the emission of electrons, the production of ions and metastable atoms as well as lifetime limiting processes the cathode region is of particular interest. To implement a discharge in spot mode a novel planar mesh electrode was developed and used as cathode. Applying the space resolved laser-atom-absorption-spectroscopy method (LAAS) the absolute particle densities of the two lowest excited xenon atoms and the gas temperature in the cathode region were determined, whereas the strong spot plasma inhomogeneity was considered. Both the excited xenon particle density and the gas temperature strongly decrease in radial and axial direction. Particularly the gas temperature has a value of about 650 K in a 1mm cathode distance and does clearly exceed room temperature. Furthermore the spectrum of the hot spot on the cathode surface was detected by means of optical emission spectroscopy. From this spectrum the temperature distribution of the cathode spot was obtained by fitting Planck's law. The temperature distribution shows a distinct maximum, which in dependence of the discharge current reaches values of 1414 K at 40 mA and 1524 K at 80 mA. From that maximum a steep direction-independent temperature decrease was obtained. A technological important aspect concerning the lifetime of a xenon based mercury-free discharge lamp is the problematic effect of the xenon gas consumption. In this work it is shown that in contrary to an industrial made standard cup electrode, which is broadly used in light advertising lamps, the gas consumption is negligible when applying the novel planar mesh electrode. This reduction of gas consumption is due to the generation of a hot spot along with high cathode temperature and low cathode fall voltage. (orig.)

  9. Study of the cathode region of mercury-free He-Xe low-pressure gas-discharge lamps with planar mesh electrode; Untersuchung der Kathodenregion von quecksilberfreien He-Xe Niederdruckgasentladungslampen mit planarer Geflechtelektrode

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Joern

    2009-12-04

    In the present work the cathode region of a mercury-free helium-xenon low pressure discharge in spot mode was experimentally investigated. Due to the emission of electrons, the production of ions and metastable atoms as well as lifetime limiting processes the cathode region is of particular interest. To implement a discharge in spot mode a novel planar mesh electrode was developed and used as cathode. Applying the space resolved laser-atom-absorption-spectroscopy method (LAAS) the absolute particle densities of the two lowest excited xenon atoms and the gas temperature in the cathode region were determined, whereas the strong spot plasma inhomogeneity was considered. Both the excited xenon particle density and the gas temperature strongly decrease in radial and axial direction. Particularly the gas temperature has a value of about 650 K in a 1mm cathode distance and does clearly exceed room temperature. Furthermore the spectrum of the hot spot on the cathode surface was detected by means of optical emission spectroscopy. From this spectrum the temperature distribution of the cathode spot was obtained by fitting Planck's law. The temperature distribution shows a distinct maximum, which in dependence of the discharge current reaches values of 1414 K at 40 mA and 1524 K at 80 mA. From that maximum a steep direction-independent temperature decrease was obtained. A technological important aspect concerning the lifetime of a xenon based mercury-free discharge lamp is the problematic effect of the xenon gas consumption. In this work it is shown that in contrary to an industrial made standard cup electrode, which is broadly used in light advertising lamps, the gas consumption is negligible when applying the novel planar mesh electrode. This reduction of gas consumption is due to the generation of a hot spot along with high cathode temperature and low cathode fall voltage. (orig.)

  10. Organ-specific accumulation, transportation, and elimination of methylmercury and inorganic mercury in a low Hg accumulating fish.

    Science.gov (United States)

    Peng, Xiaoyan; Liu, Fengjie; Wang, Wen-Xiong

    2016-08-01

    Low mercury (Hg) concentrations down to several nanograms Hg per gram of wet tissue are documented in certain fish species such as herbivorous fish, and the underlying mechanisms remain speculative. In the present study, bioaccumulation and depuration patterns of inorganic Hg(II) and methylmercury (MeHg) in a herbivorous rabbitfish Siganus canaliculatus were investigated at organ and subcellular levels following waterborne or dietary exposures. The results showed that the efflux rate constants of Hg(II) and MeHg were 0.104 d(-1) and 0.024 d(-1) , respectively, and are probably the highest rate constants recorded in fish thus far. The dietary MeHg assimilation efficiency (68%) was much lower than those in other fish species (∼90%). The predominant distribution of MeHg in fish muscle was attributable to negligible elimination of MeHg from muscle (Hg(II) was much more slowly distributed into muscle but was efficiently eliminated by the intestine (0.13 d(-1) ). Subcellular distribution indicated that some specific membrane proteins in muscle were the primary binding pools for MeHg, and both metallothionein-like proteins and Hg-rich granules were the important components in eliminating both MeHg and Hg(II). Overall, the present study's results suggest that the low tissue Hg concentration in the rabbitfish was partly explained by its unique biokinetics. Environ Toxicol Chem 2016;35:2074-2083. © 2016 SETAC. © 2016 SETAC.

  11. Photolysis of low concentration H2S under UV/VUV irradiation emitted from microwave discharge electrodeless lamps.

    Science.gov (United States)

    Xia, Lan-Yan; Gu, Ding-Hong; Tan, Jing; Dong, Wen-Bo; Hou, Hui-Qi

    2008-04-01

    The photolysis of simulating low concentration of hydrogen sulfide malodorous gas was studied under UV irradiation emitted by self-made microwave discharge electrodeless lamps (i.e. microwave UV electrodeless mercury lamp (185/253.7 nm) and iodine lamp (178.3/180.1/183/184.4/187.6/206.2 nm)). Experiments results showed that the removal efficiency (eta H2S) of hydrogen sulfide was decreased with increasing initial H2S concentration and increased slightly with gas residence time; H2S removal efficiency was decreased dramatically with enlarged pipe diameter. Under the experimental conditions with pipe diameter of 36 mm, gas flow rate of 0.42 standard l s(-1), eta H2S was 52% with initial H2S concentration of 19.5 mg m(-3) by microwave mercury lamp, the absolute removal amount (ARA) was 4.30 microg s(-1), and energy yield (EY) was 77.3 mg kW h(-1); eta H2S was 56% with initial H2S concentration of 18.9 mg m(-3) by microwave iodine lamp, the ARA was 4.48 microg s(-1), and the EY was 80.5mg kW h(-1). The main photolysis product was confirmed to be SO4(2-) with IC.

  12. Production of poinsettia (Euphorbia Pulcherrima) with light emitting diodes compared with the traditional high pressure sodium lamp

    OpenAIRE

    Thapa, Sabir

    2017-01-01

    Use of chemical are commonly used as tools for the commercial pot plant producers to grow strong, dwarfed, and compact plants. Although, these growth regulators have adverse effects on human health and the environment. So, this issue has motivated researchers to search for alternative methods for growth regulation. The aim of this study was to test light emitting diodes (LEDs) with different light qualities alone or in combination with high pressure sodium lamps (HPSs), to investigate their e...

  13. Low job control is associated with higher diastolic blood pressure in men with mildly elevated blood pressure: the Rosai Karoshi study.

    Science.gov (United States)

    Hattori, Tomomi; Munakata, Masanori

    2015-01-01

    Job strain is a risk factor for hypertension, but it is not fully understood if components of job strain, or job demand or job control per se could be related to blood pressure (BP), and if so, whether the relationship differs between normotension and mildly elevated BP. We examined resting BP, and job stress components in 113 Japanese male hospital clerks (38.1 ± 4.4 yr). Subjects were classified into normotensive (NT) (<130/85 mmHg, n=83) and mildly elevated BP (ME) (≥130/85 mmHg) groups. Diastolic BP (DBP) showed a significant interaction between group and job control level (p=0.013). Subjects with low job control demonstrated higher DBP than those with high job control (89.1 ± 2.1 vs. 82.3 ± 2.3 mmHg, p=0.042) in ME group even after adjustments for covariates while DBP did not differ between low and high job control subjects in NT group. Systolic BP (SBP) did not differ between high and low job control subjects in both groups. Neither SBP nor DBP differed between high and low demand groups in either group. Among job strain components, job control may be independently related to BP in Japanese male workers with mildly elevated BP.

  14. First principles study of elemental mercury (Hg0) adsorption on low index CoMnO3 surfaces

    International Nuclear Information System (INIS)

    Ji, Wenchao; Su, Pingru; Tang, Qingli; Cheng, Zhiwen; Shen, Zhemin; Fan, Maohong

    2017-01-01

    Highlights: • Hg 0 adsorption on low index CoMnO 3 surface was predicted by DFT method. • Hg 0 is adsorbed on the CoMnO 3 surface with chemisorption interaction. • Hg 0 has highest adsorption energy on CoMnO 3 (1 0 0) surface with Hg-Mn mechanism. • The electron transfer of Hg 0 has positive relationship with adsorption energy. - Abstract: The density functional theory (DFT) is applied to predict elemental mercury (Hg 0 ) adsorption on CoMnO 3 surface for the first time. GGA/PBE functional were selected to determine the potential Hg 0 capture mechanisms. The results show that Hg 0 has good affinity with CoMnO 3 surfaces with chemical adsorption. The adsorption energy of Hg 0 -CoMnO 3 (1 0 0), Hg 0 -CoMnO 3 (1 0 1) and Hg 0 -CoMnO 3 (1 1 0) are −85.225, −72.305 and −70.729 kJ/mol, respectively. The Hg-Mn and Hg-Co mechanisms were revealed on low index surfaces. Hg 0 was oxidized to its valence state of 0.236 on Mn site in CoMnO 3 (1 0 0) surface. The Hg-Co interaction mechanism occurred on Hg 0 -CoMnO 3 (1 0 1) and Hg 0 -CoMnO 3 (1 1 0) with 0.209e − and 0.189e − transformation, respectively. The PDOS analysis shows that Hg-Mn interaction depends on the hybridization of Hg(s- and d-orbitals) and Mn (s-, p- and d- orbitals). However, Hg-Co interaction stems from s- and d- orbitals of Hg, which only overlapping with d- and p- orbital of Co. Both the adsorption energy and electronic structure analysis indicated that CoMnO 3 catalyst performed excellent in Hg 0 oxidation. Exposing CoMnO 3 (1 0 0) is most favorable in Hg 0 control, which provides theoretical instruction on certain crystal plane synthesis in experiment.

  15. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Science.gov (United States)

    2010-10-01

    ... Devices, and Electrical Wiring § 393.24 Requirements for head lamps, auxiliary driving lamps and front fog lamps. (a) Headlamps. Every bus, truck and truck tractor shall be equipped with headlamps as required by...

  16. Modeling of diffusive plasmas in local thermodynamic equilibrium with integral constraints: application to mercury-free high pressure discharge lamp mixtures

    Science.gov (United States)

    Janssen, J. F. J.; Suijker, J. L. G.; Peerenboom, K. S. C.; van Dijk, J.

    2017-03-01

    The mercury free lamp model previously discussed in Gnybida et al (2014 J. Phys. D: Appl. Phys. 47 125201) did not account for self-consistent diffusion and only included two molecular transitions. In this paper we apply, for the first time, a self-consistent diffusion algorithm that features (1) species/mass conservation up to machine accuracy and (2) an arbitrary mix of integral (total mass) and local (cold spot) constraints on the composition. Another advantage of this model is that the total pressure of the gas is calculated self consistently. Therefore, the usage of a predetermined pressure is no longer required. Additionally, the number of association processes has been increased from 2 to 6. The population as a function of interatomic separation determines the spectrum of the emitted continuum radiation. Previously, this population was calculated using the limit of low densities. In this work an expression is used that removes this limitation. The result of these improvements is that the agreement between the simulated and measured spectra has improved considerably.

  17. Breakdown characteristics of xenon HID Lamps

    Science.gov (United States)

    Babaeva, Natalia; Sato, Ayumu; Brates, Nanu; Noro, Koji; Kushner, Mark

    2009-10-01

    The breakdown characteristics of mercury free xenon high intensity discharge (HID) lamps exhibit a large statistical time lag often having a large scatter in breakdown voltages. In this paper, we report on results from a computational investigation of the processes which determine the ignition voltages for positive and negative pulses in commercial HID lamps having fill pressures of up to 20 atm. Steep voltage rise results in higher avalanche electron densities and earlier breakdown times. Circuit characteristics also play a role. Large ballast resistors may limit current to the degree that breakdown is quenched. The breakdown voltage critically depends on cathode charge injection by electric field emission (or other mechanisms) which in large part controls the statistical time lag for breakdown. For symmetric lamps, ionization waves (IWs) simultaneously develop from the bottom and top electrodes. Breakdown typically occurs when the top and bottom IWs converge. Condensed salt layers having small conductivities on the inner walls of HID lamps and on the electrodes can influence the ignition behavior. With these layers, IWs tend to propagate along the inner wall and exhibit a different structure depending on the polarity.

  18. Low Blood Pressure

    Science.gov (United States)

    ... a problem. Sometimes blood pressure that is too low can also cause problems. Blood pressure is the ... reading is 90/60 or lower, you have low blood pressure. Some people have low blood pressure ...

  19. Low molecular weight thiols and thioredoxins are important players in Hg(II) resistance in Thermus thermophilus HB27.

    Science.gov (United States)

    Norambuena, J; Wang, Y; Hanson, T; Boyd, J M; Barkay, T

    2017-11-17

    Mercury (Hg), one of the most toxic and widely distributed heavy metals, has a high affinity for thiol groups. Thiol groups reduce and sequester Hg. Therefore, low molecular weight and protein thiols may be important cell components used in Hg resistance. To date, the role of low molecular weight thiols in Hg-detoxification remains understudied. The mercury resistance ( mer ) operon of Thermus thermophilus suggests an evolutionary link between Hg(II) resistance and low molecular weight thiol metabolism. This mer operon encodes for an enzyme involved in methionine biosynthesis, Oah. Challenge with Hg(II) resulted in increased expression of genes involved in the biosynthesis of multiple low molecular weight thiols (cysteine, homocysteine, and bacillithiol), as well as the thioredoxin system. Phenotypic analysis of gene replacement mutants indicated that Oah contributes to Hg resistance under sulfur limiting conditions, and strains lacking bacillithiol and/or thioredoxins are more sensitive to Hg(II) than the wild type. Growth in presence of either a thiol oxidizing agent or a thiol alkylating agent increased sensitivity to Hg(II). Furthermore, exposure to 3 μM Hg(II) consumed all intracellular reduced bacillithiol and cysteine. Database searches indicate that oah2 is present in all Thermus spp. mer operons. The presence of a thiol related gene was also detected in some alphaprotobacterial mer operons, in which a glutathione reductase gene was present, supporting the role of thiols in Hg(II) detoxification. These results have led to a working model in which LMW thiols act as Hg(II) buffering agents while Hg is reduced by MerA. Importance The survival of microorganisms in presence of toxic metals is central to life's sustainability. The affinity of thiol groups to toxic heavy metals drives microbe-metal interactions and modulate metal toxicity. Mercury detoxification ( mer ) genes likely originated early in microbial evolution among geothermal environments. Little is

  20. Evaluation of a contact lens-embedded sensor for intraocular pressure measurement.

    Science.gov (United States)

    Twa, Michael D; Roberts, Cynthia J; Karol, Huikai J; Mahmoud, Ashraf M; Weber, Paul A; Small, Robert H

    2010-08-01

    To evaluate a novel contact lens-embedded pressure sensor for continuous measurement of intraocular pressure (IOP). Repeated measurements of IOP and ocular pulse amplitude (OPA) were recorded in 12 eyes of 12 subjects in sitting and supine positions using 3 configurations of the dynamic contour tonometer: slit-lamp mounted (DCT), hand-held (HH), and contact lens-embedded sensor (CL). The IOP and OPA for each condition were compared using repeated measures ANOVA and the 95% limits of agreement were calculated. The sitting IOP (mean and 95% CI) for each configuration was DCT: 16.3 mm Hg (15.6 to 17.1 mm Hg), HH: 16.6 mm Hg (15.6 to 17.6 mm Hg), and CL: 15.7 mm Hg (15 to 16.3 mm Hg). The sitting OPA for each configuration was DCT: 2.4 mm Hg (2.1 to 2.6 mm Hg), HH: 2.4 mm Hg (2.1 to 2.7 mm Hg), and CL: 2.1 mm Hg (1.8 to 2.3 mm Hg). Supine IOP and OPA measurements with the CL and HH sensors were both greater than their corresponding sitting measurements, but were significantly less with the CL sensor than the HH sensor. The mean difference and 95% Limits of Agreement were smallest for the DCT and CL sensor comparisons (0.7+/-3.9 mm Hg) and widest for the CL and HH sensors (-1.9+/-7.25 mm Hg); these wider limits were attributed to greater HH measurement variability. The CL sensor was comparable to HH and DCT sensors with sitting subjects and is a viable method for measuring IOP and OPA. Supine measurements of IOP and OPA were greater than sitting conditions and were comparatively lower with the CL sensor. HH measurements were more variable than CL measurements and this influenced the Limits of Agreement for both sitting and supine conditions.

  1. Investigating the gas phase emitter effect of caesium and cerium in ceramic metal halide lamps in dependence on the operating frequency

    Energy Technology Data Exchange (ETDEWEB)

    Ruhrmann, C; Westermeier, M; Bergner, A; Awakowicz, P; Mentel, J [Ruhr University Bochum, Electrical Engineering and Plasma Technology, D-44780 Bochum (Germany); Luijks, G M J F, E-mail: juergen.mentel@ruhr-uni-bochum.de [Philips Lighting, GBU HID, PO box 80020, 5600JM Eindhoven (Netherlands)

    2011-09-07

    The work function and with it the temperature of tungsten electrodes in HID lamps can be lowered and the lifetime of lamps increased by the gas phase emitter effect. A determination of the emitter effect of Cs and Ce is performed by phase resolved measurements of the electrode tip temperature T{sub tip}({psi}), plasma temperature T{sub pl}({psi}) and particle densities N({psi}) by means of pyrometric, optical emission and broadband absorption spectroscopy in dependence on the operating frequency. The investigated HID lamps are ceramic metal halide lamps with transparent discharge vessels made of YAG, filled with a buffer gas consisting of Ar, Kr and predominantly Hg and seeded with CsI or CeI{sub 3}. In the YAG lamp seeded with CsI and CeI{sub 3} as well as in a YAG lamp seeded with DyI{sub 3} (corresponding results can be found in a preceding paper) a gas phase emitter effect is observed in the cathodic phase due to a Cs, Ce or Dy ion current. In the YAG lamp seeded with CsI the phase averaged coverage of the electrode surface with emitter atoms decreases and the electrode temperature rises with increasing frequency, whereas the emitter effect of Ce and Dy is extended to the anodic phase, which leads to a decreased average temperature T{sub tip}({psi}) with increasing frequency. This different behaviour of the averaged values of T{sub tip}({psi}) for increasing frequency is caused by the differing adsorption energies E{sub a} of the respective emitter materials. In spite of the influence of E{sub a} on the coverage of the electrode with emitter atoms, the cathodic gas phase emitter effect produces in the YAG lamps seeded with CsI, CeI{sub 3} and DyI{sub 3} a general reduction in the electrode tip temperature T{sub tip}({psi}) in comparison with a YAG lamp with Hg filling only.

  2. A new LED lamp for the collection of nocturnal Lepidoptera and a spectral comparison of light-trapping lamps

    Directory of Open Access Journals (Sweden)

    Gunnar Brehm

    2017-04-01

    Full Text Available Most nocturnal Lepidoptera can be attracted to artificial light sources, particularly to those that emit a high proportion of ultraviolet radiation. Here, I describe a newly developed LED lamp set for the use in the field that is lightweight, handy, robust, and energy efficient. The emitted electromagnetic spectrum corresponds to the peak sensitivity in most Lepidoptera eye receptors (ultraviolet, blue and green. Power LEDs with peaks at 368 nm (ultraviolet, 450 nm (blue, 530 nm (green, and 550 nm (cool white are used. I compared the irradiance (Ee of many commonly used light-trapping lamps at a distance of 50 cm. Between wavelengths of 300 and 1000 nm, irradiance from the new lamp was 1.43 W m-2. The new lamp proved to be the most energy efficient, and it emitted more radiation in the range between 300 and 400 nm than any other lamp tested. Cold cathodes are the second most energy-efficient lamps. Irradiation from fluorescent actinic tubes is higher than from fluorescent blacklight-blue tubes. High-wattage incandescent lamps and self-ballasted mercury vapour lamps have highest irradiance, but they mainly emit in the long wave spectrum. The use of gauze and sheets decreases the proportion of UV radiation and increases the share of blue light, probably due to optical brighteners. Compared with sunlight, UV irradiance is low at a distance of 50 cm from the lamp, but (safety glasses as well as keeping sufficient distance from the lamp are recommended. In field tests, the new LED lamp attracted large numbers of Lepidoptera in both the Italian Alps and in the Peruvian Andes.

  3. Development and optimization of a matrix converter supplying an electronic ballast - UV lamp system for water sterilization

    Science.gov (United States)

    Bokhtache, Aicha Aissa; Zegaoui, Abdallah; Aillerie, Michel; Djahbar, Abdelkader; Hemici, Kheira

    2018-05-01

    Electronic ballasts dedicated to discharge lamps allow improving the quality of radiation by operating at high frequency. In the present work, the use of a single-phase direct converter with a matrix structure for supplying a low-pressure mercury-argon UVC lamp for water sterilization is proposed. The structure of the converter is based on two switching cells allowing the realization of a fully controllable bidirectional switches. The advantages of such a matrix topology include the delivered of a sinusoidal waveform current with a controllable power factor close to unity, variable in amplitude and frequency. In order to obtain the desired amplitude and frequency, a PWM control was associated in the current realization. Finally, a linear adjustment of the lamp arc current was warranted by using of a PI regulator.

  4. AC ignition of HID lamps

    NARCIS (Netherlands)

    Sobota, A.; Kanters, J.H.M.; Manders, F.; Veldhuizen, van E.M.; Haverlag, M.

    2010-01-01

    Our aim was to examine the starting behaviour of mid-pressure argon discharges in pin-pin (point-to-point) geometry, typically used in HID lamps. We focused our work on AC ignition of 300 and 700 mbar Ar discharges in Philips 70W standard burners. Frequency was varied between 200 kHz and 1 MHz. In

  5. Absence of Hg transpiration by shoot after Hg uptake by roots of six terrestrial plant species

    International Nuclear Information System (INIS)

    Greger, Maria; Wang Yaodong; Neuschuetz, Clara

    2005-01-01

    In this paper we investigated if, and to what extent, six different plant species accumulate, translocate and emit mercury (Hg) into the air. The Hg uptake by roots, distribution of Hg to the shoot and release of Hg via shoots of garden pea, spring wheat, sugar beet, oil-seed rape, white clover and willow were investigated in a transpiration chamber. The airborne Hg was trapped in a Hopcalite trap or a gold trap. Traps and plant materials were analysed for content of Hg by CVAAS. The results show that all plant species were able to take up Hg to a large extent from a nutrient solution containing 200 μg L -1 Hg. However, the Hg translocation to the shoot was low (0.17-2.5%) and the Hg that reached the leaves was trapped and no release of the absorbed Hg to the air was detected. - Mercury translocation to shoots was low

  6. Economic study of replacing conventional ballast with electronic ballast for high pressure sodium lamps used in public lighting in Egypt

    Directory of Open Access Journals (Sweden)

    Osama M. Arafa

    2015-05-01

    Full Text Available High pressure sodium lamp is widely used for street and public lighting in many countries including Egypt. It is traditionally connected to the AC mains through electromagnetic ballast. Electronic ballast for high pressure sodium lamp has reached a matured technological state and it is outperforming electromagnetic ballast in almost all operational aspects. Differentiating both ballasts from a technical perspective has been presented in great detail by the authors in a previous paper. Due to the current critical shortage of electrical energy supply in Egypt; top executives seek alternatives to mitigate the crisis of electricity shortage. Among these alternatives is a national plan to replace magnetic ballasts with electronic ballasts for public lighting applications. Replacing conventional electromagnetic ballast with electronic ballast is associated with high capital investment due to high cost of such devices. The objective of this study is to outlay a systematic approach to define the threshold price of electronic ballast which assures the economical feasibility of such plan. In doing this, the economical aspects of replacing electromagnetic ballasts with electronic ballast on a national scale in Egypt are analyzed and presented.

  7. Neutron diffraction study of structural transformations in ternary systems of HgSe sub 1 sub - sub x S sub x mercury chalcogenides at high pressure

    CERN Document Server

    Voronin, V I; Berger, I F; Glazkov, V P; Kozlenko, D P; Savenko, B N; Tikhomirov, S V

    2001-01-01

    The structure of the ternary systems of the HgSe sub 1 sub - sub x S sub x mercury chalcogenides is studied at high pressures up to 35 kbar. It is established that by increase in the pressure in the HgSe sub 1 sub - sub x S sub x there takes place the transition from the sphalerite type cubic structure to the cinnabar type hexagonal structure, which is accompanied by the jump-like change in the elementary cell volume and interatomic distances. The parameters of the elementary cell and positional parameters of the Hg and Se/S for the hexagonal phase of high pressure are determined. The existence of the two-phase state in the area of the phase transformation is determined

  8. 46 CFR 53.05-3 - Materials (modifies HG-401.2).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Materials (modifies HG-401.2). 53.05-3 Section 53.05-3... Pressure Relieving Devices (Article 4) § 53.05-3 Materials (modifies HG-401.2). Materials for valves must be in accordance with HG-401.2 of section IV of the ASME Boiler and Pressure Vessel Code...

  9. Improving the work environment in the fluorescent lamp recycling sector by optimizing mercury elimination.

    Science.gov (United States)

    Lecler, Marie-Thérèse; Zimmermann, François; Silvente, Eric; Masson, Alain; Morèle, Yves; Remy, Aurélie; Chollot, Alain

    2018-02-26

    One of the main issues in the fluorescent lamp recycling sector is the mercury contamination of output fractions and occupational exposure associated with recycling operations. The aim of this study is to carry out effective mercury mass balance determinations and improve mercury recovery by finding the optimal levels for the recycling process parameters. These optimizations will allow upstream mercury emissions to be reduced, which will help to avoid mercury exposure among WEEE recycling workers. Firstly, the distribution of mercury was assessed in new and spent lamps. For new fluorescent tubes, the mean percentage of mercury in the solid phase is lower in new fluorescent tubes (19.5% with 5.5% in glass, 9.7% in end caps and 4.3% in luminescent powder) than in spent tubes (33.3% with 8.3% in glass, 12.9% in end caps and 12.1% in luminescent powder). The parametric study also shows that the finer the grains of glass, the higher the concentration of mercury (1.2 µg Hg/g for glass size particle >1000 µm and 152.0 µg Hg/g for glass size particle recycling companies employ processes combining as heating and mixing techniques for the recovery of mercury from lamps in order to both (i) remove as much of the mercury as possible in vapor form and (ii) avoid adsorption of the mercury at new sites created during the crushing process. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Peculiar behavior of magnetoresistance in HgSe single crystal with low electron concentration

    Science.gov (United States)

    Lonchakov, A. T.; Bobin, S. B.; Deryushkin, V. V.; Okulov, V. I.; Govorkova, T. E.; Neverov, V. N.

    2018-02-01

    Magnetoresistive properties of the single crystal of HgSe with a low electron concentration were studied in a wide range of temperatures and magnetic fields. Some fundamental parameters of the spectrum and scattering of electrons were experimentally determined. Two important features of magnetic transport were found—strong transverse magnetoresistance (MR) and negative longitudinal MR, which can indicate the existence of the topological phase of the Weyl semimetal (WSM) in HgSe. Taking this hypothesis into account, we suggest a modified band diagram of mercury selenide at low electron energies. The obtained results are essential for the deeper understanding of both physics of gapless semiconductors and WSMs—promising materials for various applications in electronics, spintronics, computer, and laser technologies.

  11. Determination of soluble bromine in an extra-high-pressure mercury discharge lamp by sodium hydroxide decomposition-suppressed ion chromatography.

    Science.gov (United States)

    Mitsumata, Hiroshi; Mori, Toshio; Maeda, Tatsuo; Kita, Yoshiyuki; Kohatsu, Osamu

    2006-02-01

    We have established a simple method for assaying the quantity of soluble bromine in the discharge tubes of an extra-high-pressure mercury discharge lamp. Each discharge tube is destroyed in 5 ml of 10 mM sodium hydroxide, and the recovered sodium hydroxide solution is analyzed by suppressed-ion chromatography using gradient elution. We have clarified that this method can assay less than 1 microg of soluble bromine in a discharge tube.

  12. [The influence of low partial oxygen pressure on the biolodical process of mesenchymal stromal cells].

    Science.gov (United States)

    Berezovskyĭ, V Ia; Plotnikova, L M; Vesel'skyĭ, S P; Litovka, I H

    2014-01-01

    The influence of low partial oxygen pressure (Po2) on the amino acid composition in culture medium of human mesenchymal stromal cell (MSC) lines 4BL has been studied. At 23 mm Hg (3% oxygen), a significant decrease (by 31%) in the concentration of proline and hydroxyproline was registered. Under these conditions, the concentration of serine and aspartic acid decreased by 45% compared to the control. Maximum consumption of free amino acids from the culture medium required for the synthesis of collagen (proline and hydroxyproline by 42%, serine and aspartic acid by 62%) was observed at a gas-phase Po2 of 38 mm Hg (5% O2). At Po2 76 mm Hg (10% O2), a lack of amino acids proline and hydroxyproline was only 21%, while that of glutamine and alanine amounted 12% compared to the control. This intensity ratio of consumption of amino acids may indicate that the maximum of MSC vital functions occurs at Po2 38 mm Hg.

  13. Low Blood Pressure (Hypotension)

    Science.gov (United States)

    ... lowest at night and rises sharply on waking. Blood pressure: How low can you go? What's considered low ... low blood pressure. Medications that can cause low blood pressure Some medications can cause low blood pressure, including: ...

  14. Modelling the Dynamic Interaction Power System Lamp - Application to High Pressure Mercury Gas Discharge Lamps

    OpenAIRE

    ZIANE, M.; MEDLES, K.; ADJOUDJ, M.; MILOUA, F.; DAMELINCOURT, J. J.; TILMATINE, A.

    2007-01-01

    The aim of this paper is to study the dynamic behaviour of a plant constituted by an electrical power system and a gas discharge lamp, this latter, increasingly used in street lighting, remains a nonlinear load element. Various approaches are used to represent it, one is the approximation of the discharge represented by a hot "channel", which verifies the assumption of local thermodynamic equilibrium [LTE] or the polynomial form of the conductance variation. A calculation procedure, based on ...

  15. Prediction study of structural, electronic and optical properties of XIn2S4 (X = Hg, Zn) thiospinels under pressure effect

    International Nuclear Information System (INIS)

    Yousaf, Masood; Inam, F.; Khenata, R.; Murtaza, G.; Isa, A.R.M.; Saeed, M.A.

    2014-01-01

    Highlights: • Pressure effect is employed for the first time on HgIn 2 S 4 and ZnIn 2 S 4 thiospinels. • A number of physical parameters are calculated and equations are developed. • FP-LAPW+lo method is coupled with different approximations (GGA+U and mBJ-GGA). • Relationships between pressure and parameters are in accordance with the theory. • Computed band gap values have good agreement with the experimental values. -- Abstract: First principle calculations are carried out to study the effect of pressure (up to 30 GPa) on physical properties of HgIn 2 S 4 and ZnIn 2 S 4 thiospinels. A number of structural, electronic and optical parameters are calculated, and equations are developed for their prediction at different pressures. Highly effective all electron FP-LAPW+lo method coupled with two different approximations (GGA+U and mBJ-GGA) provides very accurate results. All relationships developed between pressure and structural parameters are in full accordance with the established theory thus validating the approach used in the current study. Computed In–S bond length for ZnIn 2 S 4 matches closely with the experimental value. The band gap values of 0.920 eV (1.851 eV) and 1.68 eV (2.733 eV) are obtained with GGA+U (mBJ-GGA) at 0 GPa for HgIn 2 S 4 and ZnIn 2 S 4 , respectively. Additionally, we have calculated the optical properties, namely, the complex dielectric function, refractive index, extinction coefficient, reflectivity, optical conductivity, absorption coefficient and electron energy loss function under pressure effect for radiation up to 30.0 eV. The first critical point also known as optical’s absorption edge calculated with GGA+U (mBJ-GGA) appears at 0.939 eV (1.891 eV) and 1.701 eV (2.981 eV) for HgIn 2 S 4 and ZnIn 2 S 4 , respectively. Variation of the absorption spectrum indicates the prospective use of both compounds for device applications, which can be operated on a wide range of the energy scale. The entire work gives useful

  16. Superconductivity of Hg3NbF6 and Hg3TaF6

    International Nuclear Information System (INIS)

    Datars, W.R.; Morgan, K.R.; Gillespie, R.J.

    1983-01-01

    Low-temperature ac susceptibility measurements show that two new metallic compounds, Hg 3 TaF 6 and Hg 3 NbF 6 , are superconductors with a critical temperature of 7.0 K. Critical fields are 20% higher in Hg 3 TaF 6 but the temperature dependence of the critical field of the compounds is very similar down to 1.35 K. The critical field extrapolated to T = 0 K is 0.17 T for Hg 3 TaF 6 and 0.13 T for Hg 3 NbF 6

  17. Global Burden of Hypertension and Systolic Blood Pressure of at Least 110 to 115 mm Hg, 1990-2015.

    Science.gov (United States)

    Forouzanfar, Mohammad H; Liu, Patrick; Roth, Gregory A; Ng, Marie; Biryukov, Stan; Marczak, Laurie; Alexander, Lily; Estep, Kara; Hassen Abate, Kalkidan; Akinyemiju, Tomi F; Ali, Raghib; Alvis-Guzman, Nelson; Azzopardi, Peter; Banerjee, Amitava; Bärnighausen, Till; Basu, Arindam; Bekele, Tolesa; Bennett, Derrick A; Biadgilign, Sibhatu; Catalá-López, Ferrán; Feigin, Valery L; Fernandes, Joao C; Fischer, Florian; Gebru, Alemseged Aregay; Gona, Philimon; Gupta, Rajeev; Hankey, Graeme J; Jonas, Jost B; Judd, Suzanne E; Khang, Young-Ho; Khosravi, Ardeshir; Kim, Yun Jin; Kimokoti, Ruth W; Kokubo, Yoshihiro; Kolte, Dhaval; Lopez, Alan; Lotufo, Paulo A; Malekzadeh, Reza; Melaku, Yohannes Adama; Mensah, George A; Misganaw, Awoke; Mokdad, Ali H; Moran, Andrew E; Nawaz, Haseeb; Neal, Bruce; Ngalesoni, Frida Namnyak; Ohkubo, Takayoshi; Pourmalek, Farshad; Rafay, Anwar; Rai, Rajesh Kumar; Rojas-Rueda, David; Sampson, Uchechukwu K; Santos, Itamar S; Sawhney, Monika; Schutte, Aletta E; Sepanlou, Sadaf G; Shifa, Girma Temam; Shiue, Ivy; Tedla, Bemnet Amare; Thrift, Amanda G; Tonelli, Marcello; Truelsen, Thomas; Tsilimparis, Nikolaos; Ukwaja, Kingsley Nnanna; Uthman, Olalekan A; Vasankari, Tommi; Venketasubramanian, Narayanaswamy; Vlassov, Vasiliy Victorovich; Vos, Theo; Westerman, Ronny; Yan, Lijing L; Yano, Yuichiro; Yonemoto, Naohiro; Zaki, Maysaa El Sayed; Murray, Christopher J L

    2017-01-10

    Elevated systolic blood (SBP) pressure is a leading global health risk. Quantifying the levels of SBP is important to guide prevention policies and interventions. To estimate the association between SBP of at least 110 to 115 mm Hg and SBP of 140 mm Hg or higher and the burden of different causes of death and disability by age and sex for 195 countries and territories, 1990-2015. A comparative risk assessment of health loss related to SBP. Estimated distribution of SBP was based on 844 studies from 154 countries (published 1980-2015) of 8.69 million participants. Spatiotemporal Gaussian process regression was used to generate estimates of mean SBP and adjusted variance for each age, sex, country, and year. Diseases with sufficient evidence for a causal relationship with high SBP (eg, ischemic heart disease, ischemic stroke, and hemorrhagic stroke) were included in the primary analysis. Mean SBP level, cause-specific deaths, and health burden related to SBP (≥110-115 mm Hg and also ≥140 mm Hg) by age, sex, country, and year. Between 1990-2015, the rate of SBP of at least 110 to 115 mm Hg increased from 73 119 (95% uncertainty interval [UI], 67 949-78 241) to 81 373 (95% UI, 76 814-85 770) per 100 000, and SBP of 140 mm Hg or higher increased from 17 307 (95% UI, 17 117-17 492) to 20 526 (95% UI, 20 283-20 746) per 100 000. The estimated annual death rate per 100 000 associated with SBP of at least 110 to 115 mm Hg increased from 135.6 (95% UI, 122.4-148.1) to 145.2 (95% UI 130.3-159.9) and the rate for SBP of 140 mm Hg or higher increased from 97.9 (95% UI, 87.5-108.1) to 106.3 (95% UI, 94.6-118.1). For loss of DALYs associated with systolic blood pressure of 140 mm Hg or higher, the loss increased from 95.9 million (95% uncertainty interval [UI], 87.0-104.9 million) to 143.0 million (95% UI, 130.2-157.0 million) [corrected], and for SBP of 140 mm Hg or higher, the loss increased from 5.2 million (95% UI, 4.6-5.7 million) to 7

  18. Photoperiodic responses of Kalanchoe and chrysanthemum to radiation by an infrared lamp

    International Nuclear Information System (INIS)

    Ko, C.H.; Lee, S.B.; Jeong, B.R.

    2012-01-01

    This experiment was conducted to investigate the effect of a low intensity infrared radiation on the growth and photoperiodic responses of Kalanchoe blossfeldiana ‘Kaluna’ and ‘Taos’, and Dendranthema grandiflorum ‘Lemon Eye’ grown in growth chambers. In the first experiment, uniformly-rooted cuttings of ‘Kaluna’ and ‘Lemon Eye’ were selected and transplanted to 10 cm pots. After a week, pots were transferred from greenhouse to three environment-controlled growth chambers. All chambers were maintained at 25 ± 1 and 70% RH with an 8 hours photoperiod (760 μmol·m −2 ·s −1 ), provided by high pressure sodium and white fluorescent lamps. During the night period one chamber was left unlit (darkness), while the second and third ones were lit with an incandescent lamp (10 μmol·m −2 ·s −1 ) or an infrared lamp (15 μmol·m −2 ·s −1 ), respectively. Shoot length, root length, stem diameter, number of flowers, number of branches, fresh weight, and dry weight were measured after eight weeks. Flowering occurred on plants maintained in the unlit darkness and under an incandescent lamp during the night period, while only vegetative growth was observed under an infrared lamp. In the second experiment, cuttings of uniformly-rooted ‘Taos’ and ‘Lemon Eye’ were selected and transferred from the greenhouse to three environment-controlled growth chambers with the same environment setting as in the first experiment at a week after potting. During the night period one chamber was left unlit (darkness), the second and third ones were lit with an incandescent or an infrared heating lamp, both at a 0.3 μmol·m −2 ·s −1 PPFD level. After nine weeks, flowering in all treatments was observed, but was slightly delayed under an incandescent and an infrared heating lamp. Because both the incandescent lamp and the infrared lamp slightly delayed flowering in these two species, a more detailed experiment is necessary to find out at which

  19. Max Tech and Beyond: Fluorescent Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2

  20. Quantitative x-ray absorption imaging with a broadband source: application to high-intensity discharge lamps

    Energy Technology Data Exchange (ETDEWEB)

    Curry, J J [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States)], E-mail: jjcurry@nist.gov

    2008-07-21

    The case of x-ray absorption imaging in which the x-ray source is broadband and the detector does not provide spectral resolution is analysed. The specific motivation is observation of the Hg vapour distribution in high-intensity discharge (HID) lamps. When absorption by the vapour is small, the problem can be couched accurately in terms of a mean absorption cross section averaged over the x-ray spectral distribution, weighted by the energy-dependent response of the detector. The method is tested against a Au foil standard and then applied to Hg. The mean absorption cross section for Hg is calculated for a Ag-anode x-ray tube at accelerating voltages of 25, 30 and 35 kV, and for HIDs in fused silica or polycrystalline alumina arc tubes.

  1. 46 CFR 53.01-5 - Scope (modifies HG-100).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scope (modifies HG-100). 53.01-5 Section 53.01-5... General Requirements § 53.01-5 Scope (modifies HG-100). (a) The regulations in this part apply to steam... governing various types of pressure vessels and boilers. (b) Modifies HG-100. The requirements of Part HG of...

  2. Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry

    Directory of Open Access Journals (Sweden)

    Flor Diana Yokoay Claros Chacaltana

    2016-01-01

    Full Text Available ABSTRACT: The aim of this research was to measure the intraocular pressure (IOP of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were divided into three groups of 12 chinchillas each, by age: Group I (2-6-month-old, Group II (20 and 34 months and Group III (37 and 135 months. Ophthalmic examination was performed previously by Schirmer tear test, slit lamp biomicroscopy, indirect ophthalmoscopy and fluorescein test in all chinchillas. Three measurements of intraocular pressure were assessed on the same day (7, 12 and 19h. Tonometry was performed on both eyes using the rebound tonometer after calibration in "p" mode. Statistical analysis was performed with SigmaPlot for Windows. The mean IOP for groups I, II and III were 2.47±0.581mmHg, 2.47±0.581mmHg and 2.51±0.531mmHg, respectively. No significant differences were reported between age and IOP and no significant differences were reported between the time of day and IOP. The IOP in chinchillas did not differ significantly between genders or ages of the animals, and did not change with time of day.

  3. Approximations to the electron energy distribution and positive column models for low-pressure discharge light sources

    International Nuclear Information System (INIS)

    Lister, G G; Sheverev, V A; Uhrlandt, D

    2002-01-01

    The applicability of 'fluid' models based on analytic approximations of the electron energy distribution function (EEDF) and of kinetic models for low-pressure discharge light sources is discussed. Traditionally, 'fluid' models of fluorescent lamps assume that the EEDF is Maxwellian up to the energy of the first excited state. It is shown that such an approach is sufficiently accurate in most cases of conventional as well as of 'highly loaded' fluorescent lamps. However, this assumption is strongly violated for many rare gas glow discharges for mercury free light sources. As an example, a neon dc discharge is studied. The densities of the four lowest excited states and the electric field have been measured. The experimental results can be fairly well reproduced by a kinetic positive column model. This article was scheduled to appear in issue 14 of J. Phys. D: Appl. Phys. To access this special issue please follow this link: http://stacks.iop.org/0022-3727/35/i=14/

  4. First principles study of elemental mercury (Hg{sup 0}) adsorption on low index CoMnO{sub 3} surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Wenchao; Su, Pingru; Tang, Qingli; Cheng, Zhiwen [School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Shen, Zhemin, E-mail: zmshen@sjtu.edu.cn [School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Fan, Maohong [Department of Chemical and Petroleum Engineering, University of Wyoming, Laramie, Wyoming, 82071 (United States); School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia, 30332 (United States)

    2017-06-30

    Highlights: • Hg{sup 0} adsorption on low index CoMnO{sub 3} surface was predicted by DFT method. • Hg{sup 0} is adsorbed on the CoMnO{sub 3} surface with chemisorption interaction. • Hg{sup 0} has highest adsorption energy on CoMnO{sub 3} (1 0 0) surface with Hg-Mn mechanism. • The electron transfer of Hg{sup 0} has positive relationship with adsorption energy. - Abstract: The density functional theory (DFT) is applied to predict elemental mercury (Hg{sup 0}) adsorption on CoMnO{sub 3} surface for the first time. GGA/PBE functional were selected to determine the potential Hg{sup 0} capture mechanisms. The results show that Hg{sup 0} has good affinity with CoMnO{sub 3} surfaces with chemical adsorption. The adsorption energy of Hg{sup 0}-CoMnO{sub 3} (1 0 0), Hg{sup 0}-CoMnO{sub 3} (1 0 1) and Hg{sup 0}-CoMnO{sub 3} (1 1 0) are −85.225, −72.305 and −70.729 kJ/mol, respectively. The Hg-Mn and Hg-Co mechanisms were revealed on low index surfaces. Hg{sup 0} was oxidized to its valence state of 0.236 on Mn site in CoMnO{sub 3} (1 0 0) surface. The Hg-Co interaction mechanism occurred on Hg{sup 0}-CoMnO{sub 3} (1 0 1) and Hg{sup 0}-CoMnO{sub 3} (1 1 0) with 0.209e{sup −} and 0.189e{sup −} transformation, respectively. The PDOS analysis shows that Hg-Mn interaction depends on the hybridization of Hg(s- and d-orbitals) and Mn (s-, p- and d- orbitals). However, Hg-Co interaction stems from s- and d- orbitals of Hg, which only overlapping with d- and p- orbital of Co. Both the adsorption energy and electronic structure analysis indicated that CoMnO{sub 3} catalyst performed excellent in Hg{sup 0} oxidation. Exposing CoMnO{sub 3} (1 0 0) is most favorable in Hg{sup 0} control, which provides theoretical instruction on certain crystal plane synthesis in experiment.

  5. Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

    Science.gov (United States)

    Nealy, J. E.

    1975-01-01

    A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

  6. A model for additive transport in metal halide lamps containing mercury and dysprosium tri-iodide

    International Nuclear Information System (INIS)

    Beks, M L; Haverlag, M; Mullen, J J A M van der

    2008-01-01

    The distribution of additives in a metal halide lamp is examined through numerical modelling. A model for a lamp containing sodium iodide additives has been modified to study a discharge containing dysprosium tri-iodide salts. To study the complex chemistry the method of Gibbs minimization is used to decide which species have to be taken into account and to fill lookup tables with the chemical composition at different combinations of elemental abundance, lamp pressure and temperature. The results from the model with dysprosium additives were compared with earlier results from the lamp containing sodium additives and a simulation of a pure mercury lamp. It was found that radial segregation creates the conditions required for axial segregation. Radial segregation occurs due to the unequal diffusion of atoms and molecules. Under the right conditions convection currents in the lamp can cause axial demixing. These conditions depend on the ratio of axial convection and radial diffusion as expressed by the Peclet number. At a Peclet number of unity axial segregation is most pronounced. At low Peclet numbers radial segregation is at its worst, while axial segregation is not present. At large Peclet numbers the discharge becomes homogeneously mixed. The degree of axial segregation at a Peclet number of unity depends on the temperature at which the additive under consideration fully dissociates. If the molecules dissociate very close to the walls no molecules are transported by the convective currents in the lamp, and hence axial segregation is limited. If they dissociate further away from the walls in the area where the downward convective currents are strongest, more axial segregation is observed

  7. Survey of ophthalmic anterior segment findings and intraocular pressure in 95 North American box turtles (Terrapene spp.).

    Science.gov (United States)

    Espinheira Gomes, Filipe; Brandão, João; Sumner, Julia; Kearney, Michael; Freitas, Inês; Johnson, James; Cutler, Daniel; Nevarez, Javier

    2016-03-01

    To describe the ophthalmic biomicroscopy findings and intraocular pressures (IOP) in a captive population of box turtles and to determine whether a relationship exists between body morphometrics or health status and IOP. Hundred and three box turtles (69 Gulf coast, 24 three-toed, one ornate, one eastern, and eight unidentified) were triaged into three different color-coded groups: green (healthy), yellow (abnormal physical examination with no need for immediate care), and red (immediate care required). Both eyes were evaluated by rebound tonometry and slit-lamp biomicroscopy. Body weight and morphometric data were recorded. Intraocular pressures measurements were available for 190 eyes, slit-lamp biomicroscopy was available for 170 eyes, and morphometric data were available for 81 turtles. IOP in Gulf coast turtles (138 eyes) was 6.7 ± 1.4 mmHg OU. IOP in three-toed turtles (48 eyes) was 8.3 ± 1.5 mmHg OU, which was significantly higher than in Gulf coast turtles (P turtles only. There was a mild negative correlation between morphometrics and IOP in Gulf coast and three-toed turtles. Fifteen of 87 turtles had unilateral corneal or lenticular opacities; 3/87 had bilateral corneal or lenticular disease; and 3/87 had adnexal abnormalities. Different subspecies of box turtles have different normal intraocular pressures as measured by rebound tonometry, which was influenced by the animals' health status in one subspecies. Some morphometric parameters were found to be associated with IOP. Box turtles are often affected with ophthalmic abnormalities of unknown clinical significance. © 2015 American College of Veterinary Ophthalmologists.

  8. Comparison of efficacy of the intermittent pneumatic compression with a high- and low-pressure application in reducing the lower limbs phlebolymphedema

    Directory of Open Access Journals (Sweden)

    Taradaj J

    2015-10-01

    Full Text Available Jakub Taradaj,1 Joanna Rosińczuk,2 Robert Dymarek,2 Tomasz Halski,3 Winfried Schneider4 1Department of Physiotherapy Basics, Academy School of Physical Education in Katowice, Katowice, 2Department of Nervous System Diseases, University of Medicine in Wroclaw, Wroclaw, 3Institute of Physiotherapy, Public Higher Medical Professional School in Opole, Opole, Poland; 4Lymphology Center in Bad Berleburg, Bad Berleburg, Germany Introduction: The primary lymphedema and chronic venous insufficiency present an important medical problem, and effective physical therapeutic methods to treat this problem are still at the search phase. The aim of this study was to compare the efficacy of intermittent pneumatic compression (IPC of a high- or low-pressure level in the treatment of primary phlebolymphedema of the lower limbs.Methods: The study included 81 patients with chronic venous insufficiency and primary lymphedema of the lower limbs. Group A consisted of 28 patients who underwent a monthly antiedematous therapy including a manual lymphatic drainage, multilayer bandaging, and IPC with the output pressure of 120 mmHg. Group B consisted of 27 patients who underwent the same basic treatment as group A and IPC with the output pressure of 60 mmHg. Group C (control consisted of 26 patients who underwent only a basic treatment – without IPC.Results: After completion of the study, it was found that the greatest reduction of edema occurred in patients who underwent treatment with a pressure of 120 mmHg. The comparison of percentage reduction of edema showed a statistically significant advantage of the group A over groups B and C, both for the changes in the right (P=0.01 and the left limb (P=0.01. Results in patients undergoing intermittent compression of the lower pressure (60 mmHg were similar to those obtained in the control group.Conclusion: The IPC with the pressure of 120 mmHg inside the chambers effectively helps to reduce a phlebolymphedema

  9. [Study on the discharge properties of xeon flash lamp and experimental measurement].

    Science.gov (United States)

    Zhao, You-Quan; Miao, Pei-Liang; He, Feng; Gu, Jian; Zhai, Rui-Wei

    2014-07-01

    The Xenon flash lamp is a new type of light source for analytical instrument. The present paper analyzed the discharge process of xenon flash lamp, presented the discharge test system, and conducted experimental measurement of the voltage, current and optical pulse signal in the process of discharge. The results show that in the preliminary discharge, the free electron concentration was at a low level, so the energy was at a low level, then following the gas discharge, numerous free electrons formed in the lamp, resultin in the increase in the concentration of free electrons, therefore discharge current rised rapidly and voltage reduced. The lamp released photons to generate light pulse in the moment of ionic recombination, The pulse xenon lamp light energy output and spectral characteristic is related to electron energy in recombination and combination level of xenon, if the input energy and the energy consumption of the xenon lamp is inconsistent, it will lead to repeated capacitor charging and discharging and produce oscillation waveform. This paper is very useful for understanding the process of xenon lamp discharge, optimizing the driver circuit and the production of xenon flash lamp.

  10. Lamp-Ballast Compatibility Index for Efficient Ceramic Metal Halide Lamp Operation

    OpenAIRE

    Sourish Chatterjee

    2013-01-01

    Development of energy efficient products and exploration of energy saving potential are major challenges for present day’s technology. Ceramic Metal Halide lamp is the latest improved version of metal halide lamp that finds its wide applications in indoor commercial lighting especially in retail shop lighting. This lamp shows better performance in terms of higher lumen per watt and colour constancy in comparison to conventional metal halide lamp. The inherent negative incremental impedance of...

  11. DNA detection of Schistosoma japonicum: diagnostic validity of a LAMP assay for low-intensity infection and effects of chemotherapy in humans.

    Science.gov (United States)

    Xu, Jing; Guan, Zhi-Xun; Zhao, Bo; Wang, Yan-Yan; Cao, Yun; Zhang, Hui-Qin; Zhu, Xing-Quan; He, Yong-Kang; Xia, Chao-Ming

    2015-04-01

    Schistosomiasis has decreased significantly in prevalence and intensity of infection in China, thus more accurate and sensitive methods are desperately needed for the further control of schistosomiasis. The present work aimed to assess the utility of the loop-mediated isothermal amplification (LAMP) for detection of light intensity infection or false-negative patients and patients post-treatment, targeting the highly repetitive retrotransposon SjR2 of Schistosoma japonicum. LAMP was first assessed in rabbits with low intensity infection (EPGLAMP. Meanwhile, 42 sera from healthy individuals in a non-endemic area, and 60 sera from "healthy" residents who were identified as being negative for feces examination and immuno-methods in an endemic area were also examined. The results showed that LAMP could detect S. japonicum DNA in sera from rabbits at 3rd day post-infection. Following administration of praziquantel, the S. japonicum DNA in rabbit sera became negative at 10 weeks post-treatment. Of 110 sera from patients, LAMP showed 95.5% sensitivity, and even for 41 patients with less than 10 EPG, the sensitivity of LAMP still reached to 95.1%. For 47 patients after treatment, the negative conversion rate of S. japonicum DNA in patient sera increased from 23.4%, 61.7% to 83.0% at 3 months, 6 months and 9 months post-treatment, respectively. No false-positive result was obtained for 42 human sera from non-endemic area, while for the 60 "healthy" individuals from endemic area, 10 (16.7%) individuals were positive by LAMP, which suggested that these individuals might be false-negative patients. The present study demonstrated that the LAMP assay is sensitive, specific, and affordable, which would help reduce schistosomiasis transmission through targeted treatment of individuals, particularly for those with negative stool examinations who may yet remain infected. The LAMP assay may provide a potential tool to support schistosomiasis control and elimination strategies.

  12. Efficient photochemical generation of peroxycarboxylic nitric anhydrides with ultraviolet light-emitting diodes

    Science.gov (United States)

    Rider, N. D.; Taha, Y. M.; Odame-Ankrah, C. A.; Huo, J. A.; Tokarek, T. W.; Cairns, E.; Moussa, S. G.; Liggio, J.; Osthoff, H. D.

    2015-07-01

    Photochemical sources of peroxycarboxylic nitric anhydrides (PANs) are utilized in many atmospheric measurement techniques for calibration or to deliver an internal standard. Conventionally, such sources rely on phosphor-coated low-pressure mercury (Hg) lamps to generate the UV light necessary to photo-dissociate a dialkyl ketone (usually acetone) in the presence of a calibrated amount of nitric oxide (NO) and oxygen (O2). In this manuscript, a photochemical PAN source in which the Hg lamp has been replaced by arrays of ultraviolet light-emitting diodes (UV-LEDs) is described. The output of the UV-LED source was analyzed by gas chromatography (PAN-GC) and thermal dissociation cavity ring-down spectroscopy (TD-CRDS). Using acetone, diethyl ketone (DIEK), diisopropyl ketone (DIPK), or di-n-propyl ketone (DNPK), respectively, the source produces peroxyacetic (PAN), peroxypropionic (PPN), peroxyisobutanoic (PiBN), or peroxy-n-butanoic nitric anhydride (PnBN) from NO in high yield (> 90 %). Box model simulations with a subset of the Master Chemical Mechanism (MCM) were carried out to rationalize product yields and to identify side products. The present work demonstrates that UV-LED arrays are a viable alternative to current Hg lamp setups.

  13. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Science.gov (United States)

    Langhans, Robert W.

    1994-01-01

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. Specific technical qualities of fluorescent and HID lamps have been critically reviewed. I will direct my remarks to fluorescent and high intensity discharge (HID) lamps in growth chambers, growth rooms, and greenhouses. I will discuss the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses.

  14. Annealing temperature and O2 partial pressure dependence of T(sub c) in HgBa2CuO(4+delta)

    Science.gov (United States)

    Xiong, Q.; Cao, Y.; Chen, F.; Xue, Y. Y.; Chu, C. W.

    1994-01-01

    Samples of HgBa2CuO(4+delta) (Hg-1201) were annealed under various conditions. After carefully controlling annealing time, annealing temperature (T(sub a)) and O2 partial pressure (P(sub 0)), we were able to find the reversible annealing conditions for Hg-1201. Under 1 atm O2 at 260 C less than or equal to T(sub a) less than or equal to 400 C, the obtained T(sub c) is nearly the same (approximately 97 K). However, it decreases quickly with T(sub a) greater than 300 C in high vacuum (P(sub 0) approximately 10(exp -8) atm), and reaches zero at T(sub a) = 400 C. On the other hand, T(sub c) decreases with the decrease of T(sub a) in high-pressure O2 (approximately 500 atm) and reaches approximately 20 K at about 240 C. In the entire annealing region, the oxygen surplus varies significantly from 0.03 to 0.4, and a wide range of T(sub c) variation (0 goes to 97 K goes to 20 K) was obtained with anion doping alone.

  15. DNA detection of Schistosoma japonicum: diagnostic validity of a LAMP assay for low-intensity infection and effects of chemotherapy in humans.

    Directory of Open Access Journals (Sweden)

    Jing Xu

    2015-04-01

    Full Text Available Schistosomiasis has decreased significantly in prevalence and intensity of infection in China, thus more accurate and sensitive methods are desperately needed for the further control of schistosomiasis. The present work aimed to assess the utility of the loop-mediated isothermal amplification (LAMP for detection of light intensity infection or false-negative patients and patients post-treatment, targeting the highly repetitive retrotransposon SjR2 of Schistosoma japonicum.LAMP was first assessed in rabbits with low intensity infection (EPG<10. Then 110 patient sera from Hunan Province, China, and 47 sera after treatment by praziquantel were used to evaluate the diagnostic validity of LAMP. Meanwhile, 42 sera from healthy individuals in a non-endemic area, and 60 sera from "healthy" residents who were identified as being negative for feces examination and immuno-methods in an endemic area were also examined. The results showed that LAMP could detect S. japonicum DNA in sera from rabbits at 3rd day post-infection. Following administration of praziquantel, the S. japonicum DNA in rabbit sera became negative at 10 weeks post-treatment. Of 110 sera from patients, LAMP showed 95.5% sensitivity, and even for 41 patients with less than 10 EPG, the sensitivity of LAMP still reached to 95.1%. For 47 patients after treatment, the negative conversion rate of S. japonicum DNA in patient sera increased from 23.4%, 61.7% to 83.0% at 3 months, 6 months and 9 months post-treatment, respectively. No false-positive result was obtained for 42 human sera from non-endemic area, while for the 60 "healthy" individuals from endemic area, 10 (16.7% individuals were positive by LAMP, which suggested that these individuals might be false-negative patients.The present study demonstrated that the LAMP assay is sensitive, specific, and affordable, which would help reduce schistosomiasis transmission through targeted treatment of individuals, particularly for those with

  16. Measurement of intraocular pressure with pressure phosphene tonometry in children.

    Science.gov (United States)

    Fan, Dorothy S P; Chiu, Thomas Y H; Congdon, Nathan; Chan, Jeffrey C W; Cheung, Eva Y Y; Lam, Dennis S C

    2011-01-01

    To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children. Copyright 2011, SLACK Incorporated.

  17. Ahmed Versus Baerveldt Glaucoma Drainage Implantation in Patients With Markedly Elevated Intraocular Pressure (≥30 mm Hg).

    Science.gov (United States)

    Resende, Arthur F; Moster, Marlene R; Patel, Neal S; Lee, Daniel; Dhami, Hermandeep; Pro, Michael J; Waisbourd, Michael

    2016-09-01

    Glaucoma patients with markedly elevated intraocular pressure (IOP) are at risk for developing severe hypotony-related complications. The goal of this study was to compare the surgical outcomes of the Ahmed Glaucoma Valve (AGV) and the Baerveldt Glaucoma Implant (BGI) in this patient population. Patients with preoperative IOP≥30 mm Hg were included. Outcome measures were: (1) surgical failure (IOP>21 mm Hg or glaucoma surgery, or loss of light perception) and (2) surgical complications. A total of 75 patients were included: 37 in the AGV group and 38 in the BGI group. The mean±SD follow-up was 2.3±1.6 years for the AGV group and 2.4±1.7 years for the BGI group (P=0.643). Mean preoperative IOP was 38.7±6.5 mm Hg for the AGV group and 40.8±7.6 mm Hg for the BGI group. At the last follow-up, 10 (27.0%) patients failed in the AGV group compared with 6 (15.8%) patients in the BGI group (P=0.379). The BGI group had higher rate of flat or shallow anterior chamber (n=4, 10%) compared with the AGV group (n=0, 0%) (P=0.043). Failure rates of AGV and BGI in patients with IOP≥30 mm Hg were comparable. There were more early hypotony-related complications in the BGI group; however, none were vision threatening. Both glaucoma drainage implants were effective in treating patients with uncontrolled glaucoma in an emergency setting.

  18. Hollow-Core Fiber Lamp

    Science.gov (United States)

    Yi, Lin (Inventor); Tjoelker, Robert L. (Inventor); Burt, Eric A. (Inventor); Huang, Shouhua (Inventor)

    2016-01-01

    Hollow-core capillary discharge lamps on the millimeter or sub-millimeter scale are provided. The hollow-core capillary discharge lamps achieve an increased light intensity ratio between 194 millimeters (useful) and 254 millimeters (useless) light than conventional lamps. The capillary discharge lamps may include a cone to increase light output. Hollow-core photonic crystal fiber (HCPCF) may also be used.

  19. Pathways of CH3Hg and Hg ingestion in benthic organisms: an enriched isotope approach.

    Science.gov (United States)

    Taylor, Vivien F; Bugge, Deenie; Jackson, Brian P; Chen, Celia Y

    2014-05-06

    Mercury is a widespread contaminant in marine food webs, and identifying uptake pathways of mercury species, CH3Hg(+) and Hg(2+), into low trophic level organisms is important to understanding its entry into marine food webs. Enriched stable isotope tracers were used to study benthic vs. pelagic pathways of CH3Hg(+) and Hg(2+) uptake via food to the infaunal estuarine amphipod, Leptocheirus plumulosus. Algal cells differentially labeled with isotopically enriched CH3Hg(+) or Hg(2+) were added simultaneously to the sediment and water column of microcosms, and Hg species were monitored in amphipods and in sediment and water compartments. Methylation of Hg(2+) occurred during the course of the experiment, enhancing the uptake of Hg(2+) spikes. Trophic transfer of Hg from algae added to the water column was determined to be the major uptake route for amphipods, suggesting inputs of contaminated organic matter from the pelagic zone are important to mercury bioaccumulation even in organisms living in sediments.

  20. 49 CFR 393.25 - Requirements for lamps other than head lamps.

    Science.gov (United States)

    2010-10-01

    ... listed in paragraph (c) of this section. If motor vehicle equipment (e.g., mirrors, snow plows, wrecker...: J586—Stop Lamps for Use on Motor Vehicles Less Than 2032 mm in Overall Width, March 2000; J2261 Stop Lamps and Front- and Rear-Turn Signal Lamps for Use on Motor Vehicles 2032 mm or More in Overall Width...

  1. Application of a 222-nm krypton-chlorine excilamp to control foodborne pathogens on sliced cheese surfaces and characterization of the bactericidal mechanisms.

    Science.gov (United States)

    Ha, Jae-Won; Lee, Jae-Ik; Kang, Dong-Hyun

    2017-02-21

    This study was conducted to investigate the basic spectral properties of a 222-nm krypton-chlorine (KrCl) excilamp and its inactivation efficacy against major foodborne pathogens on solid media, as well as on sliced cheese compared to a conventional 254-nm low-pressure mercury (LP Hg) lamp. Selective media and sliced cheese inoculated with Escherichia coli O157:H7, Salmonella enterica serovar Typhimurium, and Listeria monocytogenes were irradiated with a KrCl excilamp and a LP Hg lamp at the same dose. The KrCl excilamp showed full radiant intensity from the outset at a wide range of working temperatures, especially at low temperatures of around 0 to 10°C. Irradiation with 222nm UV-C showed significantly (P<0.05) higher inactivation capacity against all three pathogens than 254-nm radiation on both media and sliced cheese surfaces without generating many sublethally injured cells which potentially could recover. The underlying inactivation mechanisms of 222-nm KrCl excilamp treatment were evaluated by fluorescent staining methods and damage to cellular membranes and intracellular enzyme inactivation were the primary factors contributing to the enhanced bactericidal effect. The results of this study suggest that a 222-nm UV-C surface disinfecting system can be applied as an alternative to conventional LP Hg lamp treatment by the dairy industry. Copyright © 2016. Published by Elsevier B.V.

  2. Time-dependent simulation of plasma and electrodes in high-intensity discharge lamps with different electrode shapes

    CERN Document Server

    Flesch, P

    2003-01-01

    The subject of this paper is the modelling of d.c. and a.c. high-intensity Hg-discharge lamps with differently shaped electrodes. Different arc attachments on the electrodes are studied and insight for the development of new electrodes is gained. The model includes the entire discharge plasma (plasma column, hot plasma spots in front of electrodes, near-electrode non-LTE-plasma) as well as anode and cathode. No subdivision of the discharge space into different regions is necessary (like space charge layer, ionization zone, plasma column). This is achieved by using a differential equation for a non-LTE electrical conductivity which is applicable for local thermal equilibrium (LTE-)regions as well as for non-LTE plasma regions close to the electrodes in a high pressure plasma. Modelling results for a 0.6 MPa mercury discharge considering six different electrode shapes (anode and cathode) are presented and compared with experimental results. The electrodes have different diameters and different electrode tips, s...

  3. Inactivation dynamics of 222 nm krypton-chlorine excilamp irradiation on Gram-positive and Gram-negative foodborne pathogenic bacteria.

    Science.gov (United States)

    Kang, Jun-Won; Kim, Sang-Soon; Kang, Dong-Hyun

    2018-07-01

    The object of this study was to elucidate the bactericidal mechanism of a 222 nm Krypton Chlorine (KrCl) excilamp compared with that of a 254 nm Low Pressure mercury (LP Hg) lamp. The KrCl excilamp had higher bactericidal capacity against Gram-positive pathogenic bacteria (Staphylococcus aureus and L. monocytogenes) and Gram-negative pathogenic bacteria (S. Typhimurium and E. coli O157:H7) than did the LP Hg lamp when cell suspensions in PBS were irradiated with each type of UV lamp. It was found out that the KrCl excilamp induced cell membrane damage as a form of depolarization. From the study of respiratory chain dehydrogenase activity and the lipid peroxidation assay, it was revealed that cell membrane damage was attributed to inactivation of enzymes related to generation of membrane potential and occurrence of lipid peroxidation. Direct absorption of UV radiation which led to photoreaction through formation of an excited state was one of the causes inducing cell damage. Additionally, generation of ROS and thus occurrence of secondary damage can be another cause. The LP Hg lamp only induced damage to DNA but not to other components such as lipids or proteins. This difference was derived from differences of UV radiation absorption by cellular materials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. A GENERIC PACKAGING TECHNIQUE USING FLUIDIC ISOLATION FOR LOW-DRIFT IMPLANTABLE PRESSURE SENSORS.

    Science.gov (United States)

    Kim, A; Powell, C R; Ziaie, B

    2015-06-01

    This paper reports on a generic packaging method for reducing drift in implantable pressure sensors. The described technique uses fluidic isolation by encasing the pressure sensor in a liquid-filled medical-grade polyurethane balloon; thus, isolating it from surrounding aqueous environment that is the major source of baseline drift. In-vitro tests using commercial micromachined piezoresistive pressure sensors show an average baseline drift of 0.006 cmH 2 O/day (0.13 mmHg/month) for over 100 days of saline soak test, as compared to 0.101 cmH 2 O/day (2.23 mmHg/month) for a non-fluidic-isolated one soaked for 18 days. To our knowledge, this is the lowest reported drift for an implantable pressure sensor.

  5. An Universal packaging technique for low-drift implantable pressure sensors.

    Science.gov (United States)

    Kim, Albert; Powell, Charles R; Ziaie, Babak

    2016-04-01

    Monitoring bodily pressures provide valuable diagnostic and prognostic information. In particular, long-term measurement through implantable sensors is highly desirable in situations where percutaneous access can be complicated or dangerous (e.g., intracranial pressure in hydrocephalic patients). In spite of decades of progress in the fabrication of miniature solid-state pressure sensors, sensor drift has so far severely limited their application in implantable systems. In this paper, we report on a universal packaging technique for reducing the sensor drift. The described method isolates the pressure sensor from a major source of drift, i.e., contact with the aqueous surrounding environment, by encasing the sensor in a silicone-filled medical-grade polyurethane balloon. In-vitro soak tests for 100 days using commercial micromachined piezoresistive pressure sensors demonstrate a stable operation with the output remaining within 1.8 cmH2O (1.3 mmHg) of a reference pressure transducer. Under similar test conditions, a non-isolated sensor fluctuates between 10 and 20 cmH2O (7.4-14.7 mmHg) of the reference, without ever settling to a stable operation regime. Implantation in Ossabow pigs demonstrate the robustness of the package and its in-vivo efficacy in reducing the baseline drift.

  6. Anti-glare LED lamps with adjustable illumination light field.

    Science.gov (United States)

    Chen, Yung-Sheng; Lin, Chung-Yi; Yeh, Chun-Ming; Kuo, Chie-Tong; Hsu, Chih-Wei; Wang, Hsiang-Chen

    2014-03-10

    We introduce a type of LED light-gauge steel frame lamp with an adjustable illumination light field that does not require a diffusion plate. Base on the Monte Carlo ray tracing method, this lamp has a good glare rating (GR) of 17.5 at 3050 lm. Compared with the traditional LED light-gauge steel frame lamp (without diffusion plate), the new type has low GR. The adjustability of the illumination light field could improve the zebra effect caused by the inadequate illumination light field of the lamp. Meanwhile, we adopt the retinal image analysis to discuss the influence of GR on vision. High GR could reflect stray light on the retinal image, which will reduce vision clarity and hasten the feeling of eye fatigue.

  7. Discharge lamp technologies

    Science.gov (United States)

    Dakin, James

    1994-01-01

    This talk is an overview of discharge lamp technology commonly employed in general lighting, with emphasis on issues pertinent to lighting for plant growth. Since the audience is primarily from the plant growth community, and this begins the light source part of the program, we will start with a brief description of the discharge lamps. Challenges of economics and of thermal management make lamp efficiency a prime concern in controlled environment agriculture, so we will emphasize science considerations relating to discharge lamp efficiency. We will then look at the spectra and ratings of some representative lighting products, and conclude with a discussion of technological advances.

  8. Compression under a mechanical counter pressure space suit glove

    Science.gov (United States)

    Waldie, James M A.; Tanaka, Kunihiko; Tourbier, Dietmar; Webb, Paul; Jarvis, Christine W.; Hargens, Alan R.

    2002-01-01

    Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, pglove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

  9. Electron beam induced Hg desorption and the electronic structure of the Hg depleted surface of Hg1/sub -//sub x/Cd/sub x/Te

    International Nuclear Information System (INIS)

    Shih, C.K.; Friedman, D.J.; Bertness, K.A.; Lindau, I.; Spicer, W.E.; Wilson, J.A.

    1986-01-01

    Auger electron spectroscopy (AES), x-ray photoemission spectroscopy (XPS), low energy electron diffraction (LEED), and angle-resolved ultraviolet photoemission spectroscopy (ARPES) were used to study the electron beam induced Hg desorption from a cleaved (110)Hg/sub 1-//sub x/Cd/sub x/Te surface and the electronic structure of the Hg depleted surface. Solid state recrystallized Hg/sub 1-//sub x/Cd/sub x/Te single crystals were used. It was found that the electron beam heating dominated the electron beam induced Hg desorption on Hg/sub 1-//sub x/Cd/sub x/Te. At the electron beam energy used, the electron beam heating extended several thousand angstroms deep. However, the Hg depletion saturated after a few monolayers were depleted of Hg atoms. At the initial stage of Hg loss (only 3%), the surface band bends upward (more p type). The ARPES spectrum showed the loss of some E vs k dispersion after 22% Hg atoms were removed from the surface region, and no dispersion was observed after 43% Hg atoms were removed. These results have important implications on the electronic structure of the surfaces and interfaces of which the stoichiometry is altered

  10. Binding of Hg by bacterial extracellular polysaccharide: a possible role in Hg tolerance.

    Science.gov (United States)

    Cruz, Kimberly; Guézennec, Jean; Barkay, Tamar

    2017-07-01

    Bacteria employ adaptive mechanisms of mercury (Hg) tolerance to survive in environments containing elevated Hg concentrations. The potential of extracellular polysaccharides (EPS) production by bacteria as a mechanism of Hg tolerance has not been previously investigated. The objectives of this study were to determine if bacterial EPS sorb Hg, and if so does sorption provide protection against Hg toxicity. Purified EPS with different chemical compositions produced by bacterial isolates from microbial mats in French Polynesian atolls and deep-sea hydrothermal vents were assessed for Hg sorption. The data showed that EPS sorbed up to 82% of Hg from solution, that this sorption was dependent on EPS composition, and that sorption was a saturable mechanism. Hg uptake capacities ranged from 0.005 to 0.454 mmol Hg/g for the different EPS. To determine if EPS production could alter bacterial Hg tolerance, Escherichia coli K-12 strains and their EPS defective mutants were tested by the disc inhibition assay. Mercury inhibited growth in a dose-dependent manner with wild-type strains having smaller (~1 mm), but statistically significant, zones of inhibition than various mutants and this difference was related to a 2-fold decline in the amount of EPS produced by the mutants relative to cell biomass. These experiments identified colanic acid and hexosamine as Hg-binding moieties in EPS. Together these data indicate that binding of Hg to EPS affords a low level of resistance to the producing bacteria.

  11. RDDS lifetime measurements of low-lying superdeformed states in {sup 194}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, R.; Dewald, A.; Kruecken, R. [Universitaet Koeln (Germany)] [and others

    1996-12-31

    The lifetimes of three low-lying states in the superdeformed (SD) yrast band of {sup 194}Hg were measured by the recoil-distance Doppler-shift method. The deduced transition quadrupole moments, Q{sub t}, equal those extracted from a DSAM measurement for the high-lying states of the band corroborate the assumption that the decay out of SD bands does not strongly affect the structure of the corresponding states. By a simple mixing-model the decay can be described assuming a very small admixture of normal-deformed (ND) states to the decaying SD states. The deduced ND mixing amplitudes for the yrast SD bands in {sup 192,194}Hg and {sup 194}Pb are presented along with average transition quadrupole moments for the lower parts of the excited SD bands.

  12. UV Lamp as a Facile Ozone Source for Structural Analysis of Unsaturated Lipids Via Electrospray Ionization-Mass Spectrometry.

    Science.gov (United States)

    Stinson, Craig A; Zhang, Wenpeng; Xia, Yu

    2018-03-01

    Ozonolysis of alkene functional groups is a type of highly specific and effective chemical reaction, which has found increasing applications in structural analysis of unsaturated lipids via coupling with mass spectrometry (MS). In this work, we utilized a low-pressure mercury lamp (6 W) to initiate ozonolysis inside electrospray ionization (ESI) sources. By placing the lamp near a nanoESI emitter that partially transmits 185 nm ultraviolet (UV) emission from the lamp, dissolved dioxygen in the spray solution was converted into ozone, which subsequently cleaved the double bonds within fatty acyls of lipids. Solvent conditions, such as presence of water and acid solution pH, were found to be critical in optimizing ozonolysis yields. Fast (on seconds time scale) and efficient (50%-100% yield) ozonolysis was achieved for model unsaturated phospholipids and fatty acids with UV lamp-induced ozonolysis incorporated on a static and an infusion nanoESI source. The method was able to differentiate double bond location isomers and identify the geometry of the double bond based on yield. The analytical utility of UV lamp-induced ozonolysis was further demonstrated by implementation on a liquid chromatography (LC)-MS platform. Ozonolysis was effected in a flow microreactor that was made from ozone permeable tubing, so that ambient ozone produced by the lamp irradiation could diffuse into the reactor and induce online ozonolysis post-LC separation and before ESI-MS. Graphical Abstract ᅟ.

  13. UV Lamp as a Facile Ozone Source for Structural Analysis of Unsaturated Lipids Via Electrospray Ionization-Mass Spectrometry

    Science.gov (United States)

    Stinson, Craig A.; Zhang, Wenpeng; Xia, Yu

    2018-03-01

    Ozonolysis of alkene functional groups is a type of highly specific and effective chemical reaction, which has found increasing applications in structural analysis of unsaturated lipids via coupling with mass spectrometry (MS). In this work, we utilized a low-pressure mercury lamp (6 W) to initiate ozonolysis inside electrospray ionization (ESI) sources. By placing the lamp near a nanoESI emitter that partially transmits 185 nm ultraviolet (UV) emission from the lamp, dissolved dioxygen in the spray solution was converted into ozone, which subsequently cleaved the double bonds within fatty acyls of lipids. Solvent conditions, such as presence of water and acid solution pH, were found to be critical in optimizing ozonolysis yields. Fast (on seconds time scale) and efficient (50%-100% yield) ozonolysis was achieved for model unsaturated phospholipids and fatty acids with UV lamp-induced ozonolysis incorporated on a static and an infusion nanoESI source. The method was able to differentiate double bond location isomers and identify the geometry of the double bond based on yield. The analytical utility of UV lamp-induced ozonolysis was further demonstrated by implementation on a liquid chromatography (LC)-MS platform. Ozonolysis was effected in a flow microreactor that was made from ozone permeable tubing, so that ambient ozone produced by the lamp irradiation could diffuse into the reactor and induce online ozonolysis post-LC separation and before ESI-MS. [Figure not available: see fulltext.

  14. Lattice defects in semiconducting Hg/1-x/Cd/x/Te alloys. III - Defect structure of undoped Hg0.6Cd0.4Te

    Science.gov (United States)

    Vydyanath, H. R.; Donovan, J. D.; Nelson, D. A.

    1981-01-01

    Hall effect measurements were carried out on undoped Hg0.6Cd0.4Te crystals quenched to room temperature subsequent to equilibration at temperatures varying from 450 to 720 C under various partial pressures of Hg. The variation of the hole concentration as a function of the partial pressure of Hg indicates that the native acceptor defects are doubly ionized. Native donor defects are found to be negligible in concentration and the p-type to n-type conversion is shown to be due to residual donors and not due to native donor defects. Thermodynamic constant for the incorporation of the doubly ionized native acceptor defect has been established.

  15. Sulfurization of Dissolved Organic Matter Increases Hg-Sulfide-Dissolved Organic Matter Bioavailability to a Hg-Methylating Bacterium.

    Science.gov (United States)

    Graham, Andrew M; Cameron-Burr, Keaton T; Hajic, Hayley A; Lee, Connie; Msekela, Deborah; Gilmour, Cynthia C

    2017-08-15

    Reactions of dissolved organic matter (DOM) with aqueous sulfide (termed sulfurization) in anoxic environments can substantially increase DOM's reduced sulfur functional group content. Sulfurization may affect DOM-trace metal interactions, including complexation and metal-containing particle precipitation, aggregation, and dissolution. Using a diverse suite of DOM samples, we found that susceptibility to additional sulfur incorporation via reaction with aqueous sulfide increased with increasing DOM aromatic-, carbonyl-, and carboxyl-C content. The role of DOM sulfurization in enhancing Hg bioavailability for microbial methylation was evaluated under conditions typical of Hg methylation environments (μM sulfide concentrations and low Hg-to-DOM molar ratios). Under the conditions of predicted metacinnabar supersaturation, microbial Hg methylation increased with increasing DOM sulfurization, likely reflecting either effective inhibition of metacinnabar growth and aggregation or the formation of Hg(II)-DOM thiol complexes with high bioavailability. Remarkably, Hg methylation efficiencies with the most sulfurized DOM samples were similar (>85% of total Hg methylated) to that observed in the presence of l-cysteine, a ligand facilitating rapid Hg(II) biouptake and methylation. This suggests that complexes of Hg(II) with DOM thiols have similar bioavailability to Hg(II) complexes with low-molecular-weight thiols. Overall, our results are a demonstration of the importance of DOM sulfurization to trace metal and metalloid (especially mercury) fate in the environment. DOM sulfurization likely represents another link between anthropogenic sulfate enrichment and MeHg production in the environment.

  16. Evidence to Maintain the Systolic Blood Pressure Treatment Threshold at 140 mm Hg for Stroke Prevention: The Northern Manhattan Study.

    Science.gov (United States)

    Dong, Chuanhui; Della-Morte, David; Rundek, Tatjana; Wright, Clinton B; Elkind, Mitchell S V; Sacco, Ralph L

    2016-03-01

    In 2014, the Eighth Joint National Committee revised the target maximum systolic blood pressure (SBP) from 140 to 150 mm Hg in patients aged ≥60 years without diabetes mellitus or chronic kidney disease. The evidence from cohort studies supporting this change was sparse, particularly among US minority populations. In the Northern Manhattan Study, 1750 participants aged ≥60 years and free of stroke, diabetes mellitus, and chronic kidney disease had SBP measured at baseline and were annually followed up for incident stroke. Mean age at baseline was 72±8 years, 63% were women, 48% Hispanic, 25% non-Hispanic white, and 25% non-Hispanic black. Among all participants, 40% were on antihypertensive medications; 43% had SBP Hg, 20% had 140 to 149 mm Hg, and 37% had ≥150 mm Hg. Over a median follow-up of 13 years, 182 participants developed stroke. The crude stroke incidence was greater among individuals with SBP≥150 mm Hg (10.8 per 1000 person-years) and SBP 140 to 149 (12.3) than among those with SBPHg had an increased risk of stroke (hazard ratio, 1.7; 95% confidence interval, 1.2-2.6) compared with those with SBP Hg. The increased stroke risk was most notable among Hispanics and non-Hispanic blacks. Raising the SBP threshold from 140 to 150 mm Hg as a new target for hypertension treatment in older individuals without diabetes mellitus or chronic kidney disease could have a detrimental effect on stroke risk reduction, especially among minority US populations. © 2016 American Heart Association, Inc.

  17. Emitter depletion studies on electrodes of 50 Hz mercury/noble gas discharge lamps during ignition

    International Nuclear Information System (INIS)

    Hoek, W.J. van den; Thijssen, T.L.G.; Heijden, A.J.H. van der; Buijsse, B.; Haverlag, M.

    2002-01-01

    The depletion of emitter from the oxide cathodes during the glow switch starting of the discharge in 50 Hz operated low-pressure mercury/noble gas discharge lamps (fluorescent lamps) has been studied. It follows from pulse ignition studies and computer-controlled ignition experiments that two plasma modes exist during ignition: a glow discharge and a vapour-arc discharge. The occurrence of these modes depends on the point of interruption with respect to the phase of the 50 Hz preheat current. The vapour arc appears to be the dominant mechanism of emitter depletion. The average emitter loss per vapour-arc pulse has been quantified by radioactive Ba tracer experiments. The nature of the vapour arc has been studied by fast photography and SEM. The vapour arc involves dielectric breakdown over the non-conducting oxide mass and gives rise to explosive emitter vapourization. (author)

  18. Application Summary Report 22: LED MR16 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P.

    2014-07-23

    This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products still do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800 lumens

  19. Photoproduction of hydroxyl radicals in aqueous solution with algae under high-pressure mercury lamp.

    Science.gov (United States)

    Liu, Xianli; Wu, Feng; Deng, Nansheng

    2004-01-01

    Photoproduction of hydroxyl radicals (*OH) could be induced in aqueous solution with algae (Nitzschia hantzschiana, etc.) and (or not) Fe3+ under high-pressure mercury lamp with an exposure time of 4 h. *OH was determined by HPLC using benzene as a probe. The photoproduction of *OH increased with increasing algae concentration. Fe3+ could enhance the photoproduction of *OH in aqueous solution with algae. The results showed that the photoproduction of *OH in algal solution with Fe3+ was greater than that in algal solution without Fe3+. The light intensity and pH affected the photoproduction of *OH in aqueous solution with algae with/without Fe3+. The photoproduction of *OH in aqueous solution with algae and Fe3+ under 250 W was greater than that under 125 W HPML. The photoproduction of *OH in algal solution (pH ranged from 4.0 to 7.0) with (or not) Fe3+ at pH 4 was the greatest.

  20. Low Pressure Robot-assisted Radical Prostatectomy With the AirSeal System at OLV Hospital: Results From a Prospective Study.

    Science.gov (United States)

    La Falce, Sabrina; Novara, Giacomo; Gandaglia, Giorgio; Umari, Paolo; De Naeyer, Geert; D'Hondt, Frederiek; Beresian, Jean; Carette, Rik; Penicka, Martin; Mo, Yujiing; Vandenbroucke, Geert; Mottrie, Alexandre

    2017-12-01

    Limited studies examined effects of pneumoperiotneum during robot-assisted radical prostatectomy (RARP) and with AirSeal. The aim of this study was to assess the effect on hemodynamics of a lower pressure pneumoperitoneum (8 mmHg) with AirSeal, during RARP in steep Trendelenburg 45° (ST). This is an institutional review board-approved, prospective, interventional, single-center study including patients treated with RARP at OLV Hospital by one extremely experienced surgeon (July 2015-February 2016). Intraoperative monitoring included: arterial pressure, central venous pressure, cardiac output, heart rate, stroke volume, systemic vascular resistance, intrathoracic pressure, airways pressures, left ventricular end-diastolic and end-systolic areas/volumes and ejection fraction, by transesophageal echocardiography, an esophageal catheter, and FloTrac/Vigileo system. Measurements were performed after induction of anesthesia with patient in horizontal (T0), 5 minutes after 8 mmHg pneumoperitoneum (TP), 5 minutes after ST (TT1) and every 30 minutes thereafter until the end of surgery (TH). Parameters modification at the prespecified times was assessed by Wilcoxon and Friedman tests, as appropriate. All analyses were performed by SPSS v. 23.0. A total of 53 consecutive patients were enrolled. The mean patients age was 62.6 ± 6.9 years. Comorbidity was relatively limited (51% with Charlson Comorbidity Index as low as 0). Despite the ST, working always at 8 mmHg with AirSeal, only central venous pressure and mean airways pressure showed a statistically significant variation during the operative time. Although other significant hemodynamic/respiratory changes were observed adding pneumoperitoneum and then ST, all variables remained always within limits safely manageable by anesthesiologists. The combination of ST, lower pressure pneumoperitoneum and extreme surgeon's experience enables to safely perform RARP. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Comparative performance analysis of shunt and series passive filter for LED lamp

    Science.gov (United States)

    Sarwono, Edi; Facta, Mochammad; Handoko, Susatyo

    2018-03-01

    Light Emitting Diode lamp or LED lamp nowadays is widely used by consumers as a new innovation in the lighting technologies due to its energy saving for low power consumption lamps for brighter light intensity. How ever, the LED lamp produce an electric pollutant known as harmonics. The harmonics is generated by rectifier as part of LED lamp circuit. The present of harmonics in current or voltage has made the source waveform from the grid is distorted. This distortion may cause inacurrate measurement, mall function, and excessive heating for any element at the grid. This paper present an analysis work of shunt and series filters to suppress the harmonics generated by the LED lamp circuit. The work was initiated by conducting several tests to investigate the harmonic content of voltage and currents. The measurements in this work were carried out by using HIOKI Power Quality Analyzer 3197. The measurement results showed that the harmonics current of tested LED lamps were above the limit of IEEE standard 519-2014. Based on the measurement results shunt and series filters were constructed as low pass filters. The bode analysis were appled during construction and prediction of the filters performance. Based on experimental results, the application of shunt filter at input side of LED lamp has reduced THD current up to 88%. On the other hand, the series filter has significantly reduced THD current up to 92%.

  2. The effect of self-absorption in hollow cathode lamp on its temperature

    International Nuclear Information System (INIS)

    Sobhanian, S.; Naghshara, H.

    2014-01-01

    It has been shown experimentally that even a small error in the calculation of the temperature inside the hollow-cathode lamp (HCL) and the current applied to the lamp, may cause a tremendous error in determination of the absorption ratio in optical resonance absorption (ORA) method. This effect is intensified nonlinearity for large absorption ratios. If a higher current is applied to a copper hollow cathode lamp, the copper density inside the lamp is increasing rapidly. Due to the cylindrical (axisymmetric) form of the lamp, the density of atoms around the main axis of the lamp becomes greater than that near the internal wall. In this case the auto-absorption (or self-absorption) is occurred and as its result, the emission spectrum produced by copper atoms is locally absorbed before going out from the lamp. This absorption is stronger near the main axis compared with the areas near the wall because of the Gaussian profile of the spectral line. Two different Cu atoms ground state lines with the similar lower state (327.4 nm and 324.7 nm) are used in this work as optical resonance absorption and the absorption coefficient is obtained for three different pressures (0.6, 4.5 and 14 µbar). The best values for copper HCL temperature and for maximum HCL current were found respectively 450 K, and 5mA. (author)

  3. Low-watt lamps seen bad in many retrofits: said to burn out pre-1978 standard ballasts

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, L.

    1982-06-21

    The standard ballasts used in early energy-efficient fluorescent lamps are vulnerable to premature burnout. Retrofitting expensive new ballasts will eliminate any savings from the lamps. GTE/Sylvania, Norelco, and Westinghouse acknowledged the problem, while General Electric had no comment. Ballasts made in the last four years have been made compatible with energy-efficient lamps. The vendors claim it is the ballast manufacturers' responsibility to inform users that their product risks early burnout. (DCK)

  4. Prediction study of structural, electronic and optical properties of XIn{sub 2}S{sub 4} (X = Hg, Zn) thiospinels under pressure effect

    Energy Technology Data Exchange (ETDEWEB)

    Yousaf, Masood [Physics Department, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor (Malaysia); Inam, F. [School of Science and Engineering, Lahore University of Management Sciences, Opposite Sector U, D.H.A. Lahore 54792 (Pakistan); Khenata, R. [Laboratoire de Physique Quantique et de Modélisation Mathématique (LPQ3M), Département de Technologie, Université de Mascara, 29000 Mascara (Algeria); Murtaza, G. [Department of Physics, Islamia College Peshawar, KPK (Pakistan); Isa, A.R.M. [Physics Department, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor (Malaysia); Saeed, M.A., E-mail: saeed@utm.my [Physics Department, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor (Malaysia)

    2014-03-15

    Highlights: • Pressure effect is employed for the first time on HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4} thiospinels. • A number of physical parameters are calculated and equations are developed. • FP-LAPW+lo method is coupled with different approximations (GGA+U and mBJ-GGA). • Relationships between pressure and parameters are in accordance with the theory. • Computed band gap values have good agreement with the experimental values. -- Abstract: First principle calculations are carried out to study the effect of pressure (up to 30 GPa) on physical properties of HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4} thiospinels. A number of structural, electronic and optical parameters are calculated, and equations are developed for their prediction at different pressures. Highly effective all electron FP-LAPW+lo method coupled with two different approximations (GGA+U and mBJ-GGA) provides very accurate results. All relationships developed between pressure and structural parameters are in full accordance with the established theory thus validating the approach used in the current study. Computed In–S bond length for ZnIn{sub 2}S{sub 4} matches closely with the experimental value. The band gap values of 0.920 eV (1.851 eV) and 1.68 eV (2.733 eV) are obtained with GGA+U (mBJ-GGA) at 0 GPa for HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4}, respectively. Additionally, we have calculated the optical properties, namely, the complex dielectric function, refractive index, extinction coefficient, reflectivity, optical conductivity, absorption coefficient and electron energy loss function under pressure effect for radiation up to 30.0 eV. The first critical point also known as optical’s absorption edge calculated with GGA+U (mBJ-GGA) appears at 0.939 eV (1.891 eV) and 1.701 eV (2.981 eV) for HgIn{sub 2}S{sub 4} and ZnIn{sub 2}S{sub 4}, respectively. Variation of the absorption spectrum indicates the prospective use of both compounds for device applications, which can be

  5. Wood's lamp examination

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003386.htm Wood lamp examination To use the sharing features on this page, please enable JavaScript. A Wood lamp examination is a test that uses ultraviolet ( ...

  6. A preliminary study of mercury exposure and blood pressure in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Guimarães Jean

    2006-10-01

    Full Text Available Abstract Background Fish is considered protective for coronary heart disease (CHD, but mercury (Hg intake from fish may counterbalance beneficial effects. Although neurotoxic effects of methylmercury (MeHg are well established, cardiovascular effects are still debated. The objective of the present study was to evaluate blood pressure in relation to Hg exposure and fish consumption among a non-indigenous fish-eating population in the Brazilian Amazon. Methods The study was conducted among 251 persons from six communities along the Tapajós River, a major tributary of the Amazon. Data was obtained for socio-demographic information, fish consumption, height and weight to determine body mass index (BMI, systolic and diastolic blood pressure, and Hg concentration in hair samples. Results Results showed that overall, systolic and diastolic blood pressure, were relatively low (mean: 113.9 mmHg ± 14.6 and 73.7 mmHg ± 11.0. Blood pressure was significantly associated with hair total Hg (H-Hg, age, BMI and gender. No association was observed between fish consumption and blood pressure, although there were significant inter-community differences. Logistic regression analyses showed that the Odds Ratio (OR for elevated systolic blood pressure (≥ 130 mmHg with H-Hg ≥ 10 μg/g was 2.91 [1.26–7.28], taking into account age, BMI, smoking, gender and community. Conclusion The findings of this preliminary study add further support for Hg cardiovascular toxicity.

  7. Interim pressure garment therapy (4-6 mmHg) and its effect on donor site healing in burn patients: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Donovan, Michelle L; Muller, Michael J; Simpson, Claire; Rudd, Michael; Paratz, Jennifer

    2016-04-26

    Pressure garment therapy (PGT) is well accepted and commonly used by clinicians in the treatment of burns scars and grafts. The medium to high pressures (24-40 mmHg) in these garments can support scar minimisation, and evidence is well documented for this particular application. However, PGT specifically for burn donor sites, of which a sequela is also scarring, is not well documented. This study protocol investigates the impact of a low pressure (4-6 mmHg) interim garment on donor site healing and scarring. With a primary purpose of holding donor dressings in place, the application of the interim pressure garment (IPG) appears to have been twofold. IPGs for donor sites have involved inconsistent application with a focus on securing wound dressing rather than scar management. However, anecdotal and observational evidence suggests that IPGs also make a difference to some patient's scar outcomes for donor sites. This study protocol outlines a randomised controlled trial designed to test the effectiveness of this treatment on reducing scarring to burn donor sites. This study is a single-centre, single (assessor)-blinded, randomised control trial in patients with burns donor sites to their thighs. Patients will be randomly allocated to a control group (with no compression to donor sites) or to an experimental group (with compression to donor sites) as the comparative treatment. Groups will be compared at baseline regarding the important prognostic indicators: donor site location, depth, size, age, and time since graft (5 days). The IPG treatment will be administered post-operatively (on day 5). Follow-up assessments and garment replacement will be undertaken fortnightly for a period of 2 months. This study focuses on a unique area of burns scar management using a low-pressure tubular support garment for the reduction of donor site scars. Such therapy specifically for donor scar management is poorly represented in the literature. This study was designed to test a

  8. On electrode erosion in fluorescent lamps during instant start

    Energy Technology Data Exchange (ETDEWEB)

    Hadrath, S.

    2006-09-15

    A fluorescent lamp driven with an 'instant start electronic control gear' starts in a glow mode. In the glow mode, which lasts typically for tens of milliseconds, the cathode fall exceeds hundreds of volts. This causes high energy ion bombardment of the electrode which heats the electrode, and induces a transition from glow to arc mode. In the arc mode the electrode emits thermionically and the cathode fall drops to the 12 - 15 V range. Unfortunately, the high energy ion bombardment during the glow mode leads also to intense sputtering of electrode material, including tungsten as well as emitter. Thus, instant started fluorescent lamps often suffer from early failures due to coil fracture. Therefore, the investigation of tungsten erosion during instant start is necessary and was the main goal of this work. The density of neutral atomic tungsten is determined by laser-induced fluorescence (LIF) and optical emission spectroscopy measurements (OES). Investigations are performed on a low-pressure argon dc discharge and on commercial fluorescent lamps. To include the entire temperature profile along the electrode the diffuse and spot operation modes of the dc lamp are studied experimentally and theoretically. The measured dependencies of the cathode temperature along the coil on the discharge and heating parameters are compared with the calculated results. For the first time the tungsten erosion during instant start of commercial fluorescent lamps was experimentally investigated in this work. The erosion process could be related to sputtering. A reconstruction of the temporal evolution of the absolute tungsten population density of the ground state during the glow mode was presented. The sputtered tungsten density increases immediately with the ignition, reaches a maximum where the discharge contracts at the end of the glow mode, and decreases some milliseconds before the glow-to-arc transition takes place. The maximum tungsten density was observed within a

  9. Efficient photochemical generation of peroxycarboxylic nitric anhydrides with ultraviolet light emitting diodes

    Science.gov (United States)

    Rider, N. D.; Taha, Y. M.; Odame-Ankrah, C. A.; Huo, J. A.; Tokarek, T. W.; Cairns, E.; Moussa, S. G.; Liggio, J.; Osthoff, H. D.

    2015-01-01

    Photochemical sources of peroxycarboxylic nitric anhydrides (PANs) are utilized in many atmospheric measurement techniques for calibration or to deliver an internal standard. Conventionally, such sources rely on phosphor-coated low-pressure mercury (Hg) lamps to generate the UV light necessary to photo-dissociate a dialkyl ketone (usually acetone) in the presence of a calibrated amount of nitric oxide (NO) and oxygen (O2). In this manuscript, a photochemical PAN source in which the Hg lamp has been replaced by arrays of ultraviolet light-emitting diodes (UV-LEDs) is described. The output of the UV-LED source was analyzed by gas chromatography (PAN-GC) and thermal dissociation cavity ring-down spectroscopy (TD-CRDS). Using acetone, diethyl ketone (DIEK), diisopropyl ketone (DIPK), or di-n-propyl ketone (DNPK), respectively, the source produces peroxyacetic (PAN), peroxypropionic (PPN), peroxyisobutanoic (PiBN), or peroxy-n-butanoic nitric anhydride (PnBN) from NO in high yield (> 90%). Box model simulations with a subset of the Master Chemical Mechanism (MCM) were carried out to rationalize products yields and to identify side products. The use of UV-LED arrays offers many advantages over conventional Hg lamp setups, including greater light output over a narrower wavelength range, lower power consumption, and minimal generation of heat.

  10. ORANGE JUICE AND BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    M. F. VALIM

    2009-01-01

    Full Text Available

    Blood pressure is the force of blood against artery walls. It is measured in millimeters of mercury (mm Hg and recorded as two numbers: systolic pressure (as the heart contracts over diastolic pressure (as the heart relaxes between beats. High blood pressure (hypertension is defined as chronically elevated high blood pressure, with systolic blood pressure (SBP of 140 mm Hg or greater, and diastolic blood pressure (DBP of 90 mm Hg or greater. High blood pressure (HBP, smoking, abnormal blood lipid levels, obesity and diabetes are risk factors for coronary heart disease, the leading cause of death in the US. Lifestyle modifications such as engaging in regular physical activity, quitting smoking and eating a healthy diet (limiting intake of saturated fat and sodium and increasing consumption of fiber, fruits and vegetables are advocated for the prevention, treatment, and control of HBP. As multiple factors influence blood pressure, the effects of each factor are typically modest, particularly in normotensive subjects, yet the combined effects can be substantial. Nutrition plays an important role in influencing blood pressure. Orange juice should be included as part of any low sodium diet and/or any blood pressure reducing eating plan, as it is sodium free, fat-free and can help meet recommended levels of potassium intake that may contribute to lower BP.

  11. Comparative study of intraocular pressure (IP in Bangladeshi individuals by contact and non contact technique

    Directory of Open Access Journals (Sweden)

    Sayed Abdul Wadud

    2016-07-01

    Full Text Available Background: Intraocular pressure (IOP is one of the most important parameters in the diagnosis and treatment of glaucoma. Glaucoma has been established as the second leading cause of blindness. The treatment of glaucoma focuses mainly on lowering intraocular pressure (IOP. The target IOP is often set to a level 20% to 30% of IOP reduction, and consequent large IOP reduction beyond 30% or even 40% in cases of advanced glaucoma The different methods of tonometery are: Goldman Applanation tonometery, Noncontact (air-puff tonometery, Perkins tonometery, Tonopen tonometery, Transpalpebral tonometery.Objective: To determine the frequency of accuracy of intraocular pressure (IOP measured by non-contact (air puff tonometer compared with Goldmann applanation tonometer.Methods: This was a non-interventional, cross sectional study conducted at a tertiary care centre of Dhaka, Bangladesh. consecutive subjects attending the BSMMU eye OPD were included in the study. IOP was measured by non-contact (air puff tonometer and a slit lamp mounted GAT in all the subjects. The study samples were selected by convenience sampling who presented for check-up in the Eye Department of community ophthalmology, Bangabandhu Sheikh Mujib Medical University, Dhaka. Bangladesh. Results:A total of 120 eyes in 60 patients were studied. The mean age of the patients was 41.60 year. study population consisted of 24 (40 % men and 36 (60 % women. The mean intraocular pressure was 13.52 &13.72 mmHg for GAT, and 16.64 & 17.44 mmHg for Air puff respectively. The range of measurements by GAT was from 10 to 23 mmHg and by Air puff was 12 to 28mmHg. The difference between IOP measured by two instruments were statistically significant (p=0.000.Conclusion: Airpuff tonometer is quick, a non-contact method to measure intraocular pressure and is useful for screening purposes and postoperative case but the measurements should be confirmed with Goldmann applanation tonometer for accurate labelling

  12. The giraffe kidney tolerates high arterial blood pressure by high renal interstitial pressure and low glomerular filtration rate

    DEFF Research Database (Denmark)

    Damkjær, Mads; Wang, T; Brøndum, E

    2015-01-01

    BACKGROUND: The tallest animal on earth, the giraffe (Giraffa camelopardalis) is endowed with a mean arterial blood pressure (MAP) twice that of other mammals. The kidneys reside at heart level and show no sign of hypertension-related damage. We hypothesized that a species-specific evolutionary...... cava generated a pressure drop of 12 ± 2 mmHg. RI was 0.27. The renal capsule was durable with a calculated burst pressure of 600 mmHg. Plasma renin and AngII were 2.6 ± 0.5 mIU L(-1) and 9.1 ± 1.5 pg mL(-1) respectively. CONCLUSION: In giraffes, GFR, ERPF and RI appear much lower than expected based...... adaption in the giraffe kidney allows normal for size renal haemodynamics and glomerular filtration rate (GFR) despite a MAP double that of other mammals. METHODS: Fourteen anaesthetized giraffes were instrumented with vascular and bladder catheters to measure glomerular filtration rate (GFR) and effective...

  13. Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poplawski, Michael E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Charles C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light output compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one

  14. Deep neuromuscular blockade and low insufflation pressure during laparoscopic hysterectomy

    DEFF Research Database (Denmark)

    Madsen, Matias Vested; Istre, Olav; Springborg, Henrik Halvor

    2017-01-01

    NMB group) or single-bolus NMB and 12 mmHg pneumoperitoneum (standard NMB group). NMB was established with rocuronium and reversed with sugammadex. Two gynaecologists registered episodes of sudden abdominal contractions, alarms from the insufflator due to increased intraabdominal pressure...

  15. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  16. PREFACE: Diagnostics for electrical discharge light sources: pushing the limits Diagnostics for electrical discharge light sources: pushing the limits

    Science.gov (United States)

    Zissis, Georges; Haverlag, Marco

    2010-06-01

    high to low pressure and dielectric barrier lamps, from breakdown to acoustic resonance. Especially in the domain of high pressure lamps, J J Curry shows how coherent and incoherent x-ray scattering can be used as an imaging technique adapted to lamps. J Hirsch et al treat the acoustic resonance phenomenon that seriously limits the frequency domain for high pressure lamp operation. M Jinno et al illustrate a method that allows for measuring Xe buffer gas pressure in Hg-free metal halide lamps for automotive applications. In the domain of low pressure lamps, M Gendre et al investigate the breakdown phase by means of optical and electrical diagnostic tools. The similarity rules used a long time ago for simulating plasma behaviour based on invariants are now serving as diagnostic tools, as shown in the paper by D Michael et al. N Dagang et al show how impurities can be detected in Hg-free electrodeless lamps and more particularly in dielectric barrier discharges emitting excimer radiation. The quality of light is illustrated by a final example by R Kozakov et al on how to qualify the light output from the lamp with respect to biological effects on humans.

  17. Use of new threshold detector 199Hg(n,n')/sup 199m/Hg for neutron spectrum unfolding

    International Nuclear Information System (INIS)

    Sakurai, K.

    1982-01-01

    The nuclear data for the 199 Hg(n,n')/sup 199m/Hg reaction are reviewed and the data are used for neutron spectrum unfolding. The neutron spectrum of the YAYOI glory-hole is unfolded by SAND II with 10 nuclear reactions including the 199 Hg(n,n')/sup 199m/Hg reaction. The ratio of the measured reaction rate to the calculated reaction rate is about 1:1.1 for the guess spectrum. The 199 Hg(n,n')/sup 199m/Hg, 115 In(n,n')/sup 115m/In, 103 Rh(n,n')/sup 103m/Rh reactions should be useful threshold detectors for the neutron dosimetry with low level fast neutron flux

  18. The Increase of Intra-Abdominal Pressure Can Affect Intraocular Pressure

    Directory of Open Access Journals (Sweden)

    Ilhan Ece

    2015-01-01

    Full Text Available Objective. This study aims to explore the usage of intraocular pressure measurements as the early indicator of the increase in intra-abdominal pressure. Methods. In this prospective study, 40 patients undergoing elective surgery were included. Patients were divided into four groups of 10 patients. The control group (Group C was not subjected to laparoscopic intervention. Laparoscopic surgery was, respectively, performed with an intra-abdominal pressure of 9, 12, and 15 mmHg in Groups L (low, M (medium, and H (high pressure. Intraocular pressure was measured binocularly in each patient at three different times (before, during, and end of surgery using a contact tonometer. Results. Patients’ gender, age, body mass index (BMI, American Society of Anesthesiology (ASA class, and operative times were not different among the groups. No complications occurred with either the surgery or measurement of intraocular pressure. Intubation was associated with a severe rise in IOP (P<0.05. An increase in intraocular pressure was seen in groups M and H (P<0.05. Conclusion. Intraocular pressure was increased in the groups with an intra-abdominal pressure of 12 mmHg or more. Measuring the intraocular pressure might be a useful method to estimate the intra-abdominal pressure. This trial is registered with NCT02319213.

  19. [Lentivirus-mediated shRNA silencing of LAMP2A inhibits the proliferation of multiple myeloma cells].

    Science.gov (United States)

    Li, Lixuan; Li, Jia

    2015-05-01

    To study the effects of lentivirus-mediated short hairpin RNA (shRNA) silencing of lysosome-associated membrane protein type 2A (LAMP2A) expression on the proliferation of multiple myeloma cells. The constructed shRNA lentiviral vector was applied to infect human multiple myeloma cell line MM.1S, and stable expression cell line was obtained by puromycin screening. Western blotting was used to verify the inhibitory effect on LAMP2A protein expression. MTT assay was conducted to detect the effect of knocked-down LAMP2A on MM.1S cell proliferation, and the anti-tumor potency of suberoylanilide hydroxamic acid (SAHA) against the obtained MM.1S LAMP2A(shRNA) stable cell line. Lactate assay was performed to observe the impact of low LAMP2A expression on cell glycolysis. The stable cell line with low LAMP2A expression were obtained with the constructed human LAMP2A-shRNA lentiviral vector. Down-regulation of LAMP2A expression significantly inhibited MM.1S cell proliferation and enhanced the anti-tumor activity of SAHA. Interestingly, decreased LAMP2A expression also inhibited MM.1S cell lactic acid secretion. Down-regulation of LAMP2A expression could inhibit cell proliferation in multiple myeloma cells.

  20. Centrifugal LabTube platform for fully automated DNA purification and LAMP amplification based on an integrated, low-cost heating system.

    Science.gov (United States)

    Hoehl, Melanie M; Weißert, Michael; Dannenberg, Arne; Nesch, Thomas; Paust, Nils; von Stetten, Felix; Zengerle, Roland; Slocum, Alexander H; Steigert, Juergen

    2014-06-01

    This paper introduces a disposable battery-driven heating system for loop-mediated isothermal DNA amplification (LAMP) inside a centrifugally-driven DNA purification platform (LabTube). We demonstrate LabTube-based fully automated DNA purification of as low as 100 cell-equivalents of verotoxin-producing Escherichia coli (VTEC) in water, milk and apple juice in a laboratory centrifuge, followed by integrated and automated LAMP amplification with a reduction of hands-on time from 45 to 1 min. The heating system consists of two parallel SMD thick film resistors and a NTC as heating and temperature sensing elements. They are driven by a 3 V battery and controlled by a microcontroller. The LAMP reagents are stored in the elution chamber and the amplification starts immediately after the eluate is purged into the chamber. The LabTube, including a microcontroller-based heating system, demonstrates contamination-free and automated sample-to-answer nucleic acid testing within a laboratory centrifuge. The heating system can be easily parallelized within one LabTube and it is deployable for a variety of heating and electrical applications.

  1. High-Power 365 nm UV LED Mercury Arc Lamp Replacement for Photochemistry and Chemical Photolithography.

    Science.gov (United States)

    Hölz, K; Lietard, J; Somoza, M M

    2017-01-03

    Ultraviolet light emitting diodes (UV LEDs) have become widespread in chemical research as highly efficient light sources for photochemistry and photopolymerization. However, in more complex experimental setups requiring highly concentrated light and highly spatially resolved patterning of the light, high-pressure mercury arc lamps are still widely used because they emit intense UV light from a compact arc volume that can be efficiently coupled into optical systems. Advances in the deposition and p -type doping of gallium nitride have recently permitted the manufacture of UV LEDs capable of replacing mercury arc lamps also in these applications. These UV LEDs exceed the spectral radiance of mercury lamps even at the intense I-line at 365 nm. Here we present the successful exchange of a high-pressure mercury arc lamp for a new generation UV LED as a light source in photolithographic chemistry and its use in the fabrication of high-density DNA microarrays. We show that the improved light radiance and efficiency of these LEDs offer substantial practical, economic and ecological advantages, including faster synthesis, lower hardware costs, very long lifetime, an >85-fold reduction in electricity consumption and the elimination of mercury waste and contamination.

  2. Treating high-mercury-containing lamps using full-scale thermal desorption technology.

    Science.gov (United States)

    Chang, T C; You, S J; Yu, B S; Chen, C M; Chiu, Y C

    2009-03-15

    The mercury content in high-mercury-containing lamps are always between 400 mg/kg and 200,000 mg/kg. This concentration is much higher than the 260 mg/kg lower boundary recommended for the thermal desorption process suggested by the US Resource Conservation and Recovery Act. According to a Taiwan EPA survey, about 4,833,000 cold cathode fluorescent lamps (CCFLs), 486,000 ultraviolet lamps and 25,000 super high pressure mercury lamps (SHPs) have been disposed of in the industrial waste treatment system, producing 80, 92 and 9 kg-mercury/year through domestic treatment, offshore treatment and air emissions, respectively. To deal with this problem we set up a full-scale thermal desorption process to treat and recover the mercury from SHPs, fluorescent tube tailpipes, fluorescent tubes containing mercury-fluorescent powder, and CCFLs containing mercury-fluorescent powder and monitor the use of different pre-heating temperatures and desorption times. The experimental results reveal that the average thermal desorption efficiency of SHPs and fluorescent tube tailpipe were both 99.95%, while the average thermal desorption efficiencies of fluorescent tubes containing mercury-fluorescent powder were between 97% and 99%. In addition, a thermal desorption efficiency of only 69.37-93.39% was obtained after treating the CCFLs containing mercury-fluorescent powder. These differences in thermal desorption efficiency might be due to the complexity of the mercury compounds contained in the lamps. In general, the thermal desorption efficiency of lamps containing mercury-complex compounds increased with higher temperatures.

  3. Blood pressure hyperreactivity: an early cardiovascular risk in normotensive men exposed to low-to-moderate inorganic arsenic in drinking water.

    Science.gov (United States)

    Kunrath, Julie; Gurzau, Eugen; Gurzau, Anca; Goessler, Walter; Gelmann, Elyssa R; Thach, Thu-Trang; McCarty, Kathleen M; Yeckel, Catherine W

    2013-02-01

    Essential hypertension is associated with chronic exposure to high levels of inorganic arsenic in drinking water. However, early signs of risk for developing hypertension remain unclear in people exposed to chronic low-to-moderate inorganic arsenic. We evaluated cardiovascular stress reactivity and recovery in healthy, normotensive, middle-aged men living in an arsenic-endemic region of Romania. Unexposed (n = 16) and exposed (n = 19) participants were sampled from communities based on WHO limits for inorganic arsenic in drinking water (Water sources and urine samples were collected and analyzed for inorganic arsenic and its metabolites. Functional evaluation of blood pressure included clinical, anticipatory, cold pressor test, and recovery measurements. Blood pressure hyperreactivity was defined as a combined stress-induced change in SBP (> 20 mmHg) and DBP (>15 mmHg). Drinking water inorganic arsenic averaged 40.2 ± 30.4 and 1.0 ± 0.2 μg/l for the exposed and unexposed groups, respectively (P pressure hyperreactivity to both anticipatory stress (47.4 vs. 12.5%; P = 0.035) and cold stress (73.7 vs. 37.5%; P = 0.044). Moreover, the exposed group exhibited attenuated blood pressure recovery from stress and a greater probability of persistent hypertensive responses (47.4 vs. 12.5%; P = 0.035). Inorganic arsenic exposure increased stress-induced blood pressure hyperreactivity and poor blood pressure recovery, including persistent hypertensive responses in otherwise healthy, clinically normotensive men. Drinking water containing even low-to-moderate inorganic arsenic may act as a sympathetic nervous system trigger for hypertension risk.

  4. Lamp for sunshine simulation

    DEFF Research Database (Denmark)

    2016-01-01

    A lamp system is provided, comprising a lamp with a lamp housing accommodating a plurality of light sources for emission of visible light, including blue light, a time keeping unit, a light sensor for sensing intensity of light incident upon it, and a light controller configured for controlling...... the plurality of light sources in response to the intensity of light sensed by the light sensor and the time provided by the time keeping unit, characterized in that the lamp emits blue light for a selected time period, wherein the blue light has a luminous flux ranging from 50 lux to 200 lux and, preferably......, an irradiance that is larger than 5 mW/nm/m2 in a selected wavelength range, such as in the wavelength range from 440 nm to 500 nm, as measured at a distance of 3 metres from the lamp....

  5. The design of optical module of LED street lamp with non-axial symmetrical reflector

    Science.gov (United States)

    Lu, Ming-Jun; Chen, Chi-An; Chen, Yi-Yung; Whang, Allen Jong-Woei

    2010-05-01

    In recently, many research focus on the LED applications for environmental protection so a number of LED street lamps are presented. Although LED has many advantages for environmental protection, its special optical characteristics, such as intensity distribution, always limit the advantages in many applications. Therefore, we always need to do the secondary optical design for LED street lamp to replace the traditional optical designs that are designed for high-pressure sodium lamps and mercury lamps. According to the situation, we design an optical module of LED street lamp with LEDs and secondary optical design. First, the LEDs are placed on freeform reflector for the specific illuminated conditions. We design the optical module of street lamp with the two conditions that include the uniformity and the ratio of length to width in the illuminated area and without any light pollution. According to the simulation with the designed optical module, the uniformity in the illuminated area is about 0.6 that is better than the general condition, 0.3, and the ratio of length to width in the illuminated area is 3:1 in which the length is 30 meters and the width is 10 meters. Therefore, the design could let LED street lamp fits the two conditions, uniformity and ratio in the illuminated area.

  6. Intraocular pressure control of a novel glaucoma drainage device - in vitro and in vivo studies

    Directory of Open Access Journals (Sweden)

    Li-Jun Cui

    2017-09-01

    Full Text Available AIM: To evaluate the intraocular pressure (IOP control of an artificial trabeculum drainage system (ATDS, a newly designed glaucoma drainage device, and postoperative complications in normal rabbit eyes. METHODS: Pressure drops in air and fluid of 30 ATDS were measured after being connected to a closed manometric system. Twenty of them were then chosen and implanted randomly into the eyes of 20 rabbits. Postoperative slit-lamp, gonioscopic examination and IOP measurements were recorded periodically. Ultrasound biomicroscopy and B-scan ultrasonography were also used to observe the complications. Eyes were enucleated on day 60. RESULTS: Pressure drops of 4.6-9.4 mm Hg were obtained at physiological aqueous flow rates in the tests in vitro. The average postoperative IOP of the experimental eyes (11.6-12.8 mm Hg was lower than the controls significantly (P<0.05 at each time point. Complications of hemorrhage (n=1, cellulosic exudation (two cases and local iris congestion (two cases were observed. The lumina of the devices were devoid of obstructions in all specimens examined and a thin fibrous capsule was found around the endplate. CONCLUSION: ATDS reduce IOP effectively. However, further studies on the structure are needed to reduce complications.

  7. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1989-08-15

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction.

  8. Comparison of pressure between barium reduction and air reduction of the intussusception in children

    International Nuclear Information System (INIS)

    Lee, Kyung Hwan; Park, Sang Gyu; Park, Choong Ki; Yoon, Jong Sup

    1989-01-01

    There are many method of treatment of the intussusception in children, including surgery, barium reduction, air reduction, and saline enema under ultrasonographic monitoring. Among them, barium reduction and air reduction have been used widely as nonsurgical method of treatment in radiologic department. During barium reduction, the bottle filled with barium solution must not be elevated over a 3 feet from the operating table. In air reduction, diagnostic pressure is about 60 mmHg and pressure during reduction usually is maintained between 90 mmHg and 130 mmHg. The authors have studied about pressure difference of barium solution by changing height of the bottle filled with barium solution, and have compared with pressure in air reduction. The results are as follows; 1. Pressure of 20 w/v % barium solution at the 60 cm height is 44.4 mmHg, and 69.6 mmHg at the 90 cm height. 2. Pressure of 40 w/v % barium solution at the 60 cm height is 51.4 mmHg, and 80.1 mmHg at the 90 cm height. 3. Pressure of 40 w/v % barium solution at the 90cm height is much lower than the pressure maintained during air reduction, and this difference in pressure may be one of the causes of low reduction rate in barium reduction then air reduction. 4. The pressure gradient per 10 cm height is about 8.45 mmHg in 20 w/v % barium solution, about 9.21 mmHg in 30 w/v % barium solution, and about 9.72 mmHg 40 w/v % barium solution. 5. Intraluminal pressure difference between the barium reduction and the air reduction is probably of the major causes of rapid diagnosis and high reduction rate in the air reduction

  9. Comment on 'The equations for electronegative plasmas are not singular at the plasma centre at low pressures' by R N Franklin

    International Nuclear Information System (INIS)

    Lampe, Martin; Manheimer, Wallace M; Fernsler, Richard F; Slinker, Steven P; Joyce, Glenn

    2006-01-01

    Franklin's criticism (Franklin R N 2005 J. Phys. D: Appl. Phys. 38 2790) of our previous paper (Lampe M et al 2004 Plasma Sources Sci. Technol. 13 15-26) is based on three arguments: (1) that the limit of weak attachment is equivalent to low pressure, where our model is inappropriate; (2) that our use of the T n → 0 limit is inappropriate; (3) that the negative ion density n n is never singular at the centre. We point out that the weak attachment limit also corresponds (at high pressure) to low fraction of attaching gas, give conditions for the T n → 0 limit and discuss its consequences, and reiterate that we never argued that n n (0) is infinite, but rather discussed a quite different type of singularity. This correspondence is now closed. (comment)

  10. Mercury Flow Through the Mercury-Containing Lamp Sector of the Economy of the United States

    Science.gov (United States)

    Goonan, Thomas G.

    2006-01-01

    Introduction: This Scientific Investigations Report examines the flow of mercury through the mercury-containing lamp sector of the U.S. economy in 2001 from lamp manufacture through disposal or recycling. Mercury-containing lamps illuminate commercial and industrial buildings, outdoor areas, and residences. Mercury is an essential component in fluorescent lamps and high-intensity discharge lamps (high-pressure sodium, mercury-vapor, and metal halide). A typical fluorescent lamp is composed of a phosphor-coated glass tube with electrodes located at either end. Only a very small amount of the mercury is in vapor form. The remainder of the mercury is in the form of either liquid mercury metal or solid mercury oxide (mercury oxidizes over the life of the lamp). When voltage is applied, the electrodes energize the mercury vapor and cause it to emit ultraviolet energy. The phosphor coating absorbs the ultraviolet energy, which causes the phosphor to fluoresce and emit visible light. Mercury-containing lamps provide more lumens per watt than incandescent lamps and, as a result, require from three to four times less energy to operate. Mercury is persistent and toxic within the environment. Mercury-containing lamps are of environmental concern because they are widely distributed throughout the environment and are easily broken in handling. The magnitude of lamp sector mercury emissions, estimated to be 2.9 metric tons per year (t/yr), is small compared with the estimated mercury losses of the U.S. coal-burning and chlor-alkali industries, which are about 70 t/yr and about 90 t/yr, respectively.

  11. Developing low-cost carbon-based sorbents for Hg capture from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Ron Perry; Janos Lakatos; Colin E. Snape; Cheng-gong Sun [University of Nottingham (United Kingdom). UK Nottingham Fuel and Energy Centre, School of Chemical, Environmental and Mining Engineering

    2005-07-01

    To help reduce the cost of Hg capture, a number of low-cost carbons are being investigated, including tyre char, PFA carbons and gasification residues. This contribution reports the breakthrough capacities in fixed-bed screening tests for these materials in relation to those for commercial active carbons, including Norit FGD and the extent to which breakthrough capacities can be improved by MnO{sub 2} impregnation. 7 refs., 3 figs., 1 tab.

  12. HgSe(Te)-HgHal2 systems

    International Nuclear Information System (INIS)

    Pan'ko, V.V.; Khudolij, V.A.; Voroshilov, Yu.V.

    1989-01-01

    Using the methods of differential thermal and X-ray phase analyses the character of chemical interaction in the systems HgTe(Se)-HgHal 2 , where Hal is Cl, Br, I, is investigated. Formation of compounds Hg 3 Se 2 Hal 2 , Hg 3 Te 2 Hal 2 , Hg 3 TeCl 4 and Hg 3 TeBr 4 in these systems is established. The phase diagrams of the studied systems are presented. The parameters of elementary cells of the compounds with the unknown structure, as well as their unknown physicochemical properties, are determined

  13. Fluorescence emissions from mixtures of Hg with the noble gases

    International Nuclear Information System (INIS)

    Woodworth, J.R.

    1977-01-01

    Fluorescence emissions from mixtures of Hg with high pressure Xe, Kr, and Ar (approx.1 torr Hg, 10 3 --10 4 torr noble gas) have been studied using a short-pulse relativistic electron beam as an excitation source. Hg--noble gas molecular bands were observed on the red sides of the Hg lines (1849 and 2537 A) as well as on the red sides of the Hg visible lines (7 3 S 1 →6 3 P 0 , 1 , 2 ). Temporal histories and production efficiencies of the molecular emissions were determined and a model was formulated for the time histories of the HgXe 2600 A bands. Possible applications to high power laser systems are discussed

  14. Harmonics Monitoring Survey on LED Lamps

    Directory of Open Access Journals (Sweden)

    Abdelrahman Ahmed Akila

    2017-03-01

    Full Text Available Light Emitting Diode (LED lamps are being increasingly used in many applications. These LED lamps operate using a driver, which is a switching device. Hence, LED lamps will be a source of harmonics in the power system. These harmonics if not well treated, may cause severe performance and operational problems. In this paper, harmonics (amplitude and phase angles generated by both LED lamps and conventional fluorescent lamps will be studied practically. Then they will be analyzed and evaluated. Compared to each other harmonics generated by both LED and conventional florescent lamps, self mitigation may occur based on the phase angle of these harmonics. All data will be measured using power analyzer and will be done on a sample of actual lamps.

  15. High-intensity discharge lamp and Duffing oscillator—Similarities and differences

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Stein, Ulrich; Hallerberg, Sarah; Wolff, Marcus

    2017-12-01

    The processes inside the arc tube of high-intensity discharge lamps are investigated using finite element simulations. The behavior of the gas mixture inside the arc tube is governed by differential equations describing mass, energy, and charge conservation, as well as the Helmholtz equation for the acoustic pressure and the Reynolds equations for the flow driven by buoyancy and Reynolds stresses. The model is highly nonlinear and requires a recursion procedure to account for the impact of acoustic streaming on the temperature and other fields. The investigations reveal the presence of a hysteresis and the corresponding jump phenomenon, quite similar to a Duffing oscillator. The similarities and, in particular, the differences of the nonlinear behavior of the high-intensity discharge lamp to that of a Duffing oscillator are discussed. For large amplitudes, the high-intensity discharge lamp exhibits a stiffening effect in contrast to the Duffing oscillator. It is speculated on how the stiffening might affect hysteresis suppression.

  16. Ultraviolet radiation and blue-light emissions from spotlights incorporating tungsten halogen lamps

    CERN Document Server

    MacKinlay, Alistair F; Whillock, M J

    1989-01-01

    This report summarises measurements of the ultraviolet radiation and blue-light emissions from eleven 'desk-top' tungsten halogen (quartz) lamps and one 'floor-standing' tungsten halogen (quartz) lamp available in the UK. Values of occupational hazard weighted and erythemally weighted ultraviolet radiation irradiance and measurements and relevant calculations of blue-light hazards are presented. It is concluded that the safety design of some desk-top tungsten halogen lamps is inadequate to prevent unnecessary exposure of the skin to potentially harmful ultraviolet radiation. It is recommended that all tungsten halogen lamps should have sufficient filtration to reduce their ultraviolet emissions to an acceptably low level. As long as the comfort aversion responses of the eye are respected, direct viewing of the lamps examined should not constitute a retinal hazard.

  17. Ultraviolet radiation and blue-light emissions from spotlights incorporating tungsten halogen lamps

    International Nuclear Information System (INIS)

    McKinlay, A.F.; Whillock, M.J.; Meulemans, C.C.E.

    1989-07-01

    This report summarises measurements of the ultraviolet radiation and blue-light emissions from eleven 'desk-top' tungsten halogen (quartz) lamps and one 'floor-standing' tungsten halogen (quartz) lamp available in the UK. Values of occupational hazard weighted and erythemally weighted ultraviolet radiation irradiance and measurements and relevant calculations of blue-light hazards are presented. It is concluded that the safety design of some desk-top tungsten halogen lamps is inadequate to prevent unnecessary exposure of the skin to potentially harmful ultraviolet radiation. It is recommended that all tungsten halogen lamps should have sufficient filtration to reduce their ultraviolet emissions to an acceptably low level. As long as the comfort aversion responses of the eye are respected, direct viewing of the lamps examined should not constitute a retinal hazard. (author)

  18. Impact of mean arterial pressure on sublingual microcirculation during cardiopulmonary bypass - secondary outcome from a randomised clinical trial

    DEFF Research Database (Denmark)

    Holmgaard, Frederik; Vedel, Anne G; Ravn, Hanne Berg

    2018-01-01

    . METHODS: Thirty-six cardiac surgery patients undergoing coronary artery bypass grafting were included and randomised to either low (40-50 mmHg) or high (70-80 mmHg) mean arterial pressure during cardiopulmonary bypass. Sidestream Dark Field video images were recorded from the sublingual mucosa. Recordings...... were analysed in a blinded fashion to quantify microcirculatory variables. RESULTS: Mean arterial pressure during cardiopulmonary bypass in the low target group was 45.0 mmHg (SD 5.3) vs. 67.2 mmHg (SD 8.9) in the high target group. We found no significant difference between the two groups......OBJECTIVE: In this substudy of a randomised, clinical trial, we explored the sublingual microcirculation during cardiac surgery at two different levels of blood pressure. We hypothesised that a higher mean arterial pressure during cardiopulmonary bypass would cause higher Microvascular Flow Index...

  19. Low-pressure

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Richard [Membrane Technology And Research, Inc., Newark, CA (United States); Kniep, Jay [Membrane Technology And Research, Inc., Newark, CA (United States); Hao, Pingjiao [Membrane Technology And Research, Inc., Newark, CA (United States); Chan, Chi Cheng [Membrane Technology And Research, Inc., Newark, CA (United States); Nguyen, Vincent [Membrane Technology And Research, Inc., Newark, CA (United States); Huang, Ivy [Membrane Technology And Research, Inc., Newark, CA (United States); Amo, Karl [Membrane Technology And Research, Inc., Newark, CA (United States); Freeman, Brice [Membrane Technology And Research, Inc., Newark, CA (United States); Fulton, Don [Membrane Technology And Research, Inc., Newark, CA (United States); Ly, Jennifer [Membrane Technology And Research, Inc., Newark, CA (United States); Lipscomb, Glenn [Membrane Technology And Research, Inc., Newark, CA (United States); Lou, Yuecun [Membrane Technology And Research, Inc., Newark, CA (United States); Gogar, Ravikumar [Membrane Technology And Research, Inc., Newark, CA (United States)

    2015-01-29

    This final technical progress report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the Department of Energy (DOE NETL) on development of low-pressure membrane contactors for carbon dioxide (CO2) capture from power plant flue gas (award number DE-FE0007553). The work was conducted from October 1, 2011 through September 30, 2014. The overall goal of this three-year project was to build and operate a prototype 500 m2 low-pressure sweep membrane module specifically designed to separate CO2 from coal-fired power plant flue gas. MTR was assisted in this project by a research group at the University of Toledo, which contributed to the computational fluid dynamics (CFD) analysis of module design and process simulation. This report details the work conducted to develop a new type of membrane contactor specifically designed for the high-gas-flow, low-pressure, countercurrent sweep operation required for affordable membrane-based CO2 capture at coal power plants. Work for this project included module development and testing, design and assembly of a large membrane module test unit at MTR, CFD comparative analysis of cross-flow, countercurrent, and novel partial-countercurrent sweep membrane module designs, CFD analysis of membrane spacers, design and fabrication of a 500 m2 membrane module skid for field tests, a detailed performance and cost analysis of the MTR CO2 capture process with low-pressure sweep modules, and a process design analysis of a membrane-hybrid separation process for CO2 removal from coal-fired flue gas. Key results for each major task are discussed in the report.

  20. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  1. Marker lamps

    International Nuclear Information System (INIS)

    Watkins, D.V.

    1980-01-01

    A marker lamp is described which consists of a block of transparent plastics material encapsulated in which is a radioactive light source. These lights comprise a small sealed glass capsule, the hollow inside surface of which is coated with phosphor and which contains tritium or similar radioactive gas. The use of such lamps for identification marking of routes, for example roads, and for identification of underwater oil pipelines is envisaged. (U.K.)

  2. CALiPER Retail Lamps Study RRL3.2 Lumen and Chromaticity Maintenance of LED A lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McCullough, Jeffrey J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Joseph C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    new technology trying to build a reputation with consumers. Beyond the observed parametric failures nearly half of the products failed to meet early-life thresholds for lumen maintenance, which were borrowed from ENERGY STAR specifications. That is, the lumen maintenance was sufficiently low at 6,000 hours that seven of the products are unlikely to have lumen maintenance above 70% at their rated lifetime (which was usually 25,000 hours). Given the methods used for this investigation—most notably continuous operation—the results should not be interpreted as indicative of a lamp’s performance in a typical environment. Likewise, these results are not directly relatable to manufacturer lifetime claims. This report is best used to understand the variation in LED product performance, compare the robustness of LED lamps and benchmark conventional lamps, and understand the characteristics of lumen and chromaticity change. A key takeaway is that the long-term performance of LED lamps can vary greatly from model to model (i.e., the technology is not homogenous), although the lamp-to-lamp consistency within a given model is relatively good. Further, operation of LED lamps in an enclosed luminaire (or otherwise in high ambient temperatures), can induce parametric failure of LEDs much earlier than their rated lifetime; manufacturer warnings about such conditions should be followed if performance degradation is unacceptable.

  3. Perturbed angular correlations studies in the HgBa$_2$CaCu$_2$O$_{6+\\delta}$ high-T$_c$ superconductor

    CERN Document Server

    Mendonca, Tania Melo; Haas, Heinz; Odier, Philippe; Tavares, Pedro; SIlva, Manuel Ribeiro; Lopes, Armandina; Darie, Celine; Araujo, Joao Pedro

    2011-01-01

    The electric field gradients at $^{199m}$Hg nuclei have been measured via the perturbed angular correlation (PAC) technique, allowing a full characterization of the Hg neighborhood charge distribution at high oxygen doping on the Hg planes. The PAC technique has been applied to investigate the effect of high oxygen pressure during the measurement. Polycrystalline HgBa$_2$CaCu$_2$O$_{6+\\delta}$ (Hg-1212) samples have been annealed at 152 bar pressurized oxygen. The influence of oxygen pressure during the experiment was then investigated by measuring the samples at atmospheric pressure and under 152 bar oxygen pressure. The present set of PAC experiments shows that at high oxygen concentrations there is a non-uniform oxygen distribution. Moreover, the Hg environment is not free from oxygen and the results hint to a new type of ordering.

  4. Transparent ceramic lamp envelope materials

    Energy Technology Data Exchange (ETDEWEB)

    Wei, G C [OSRAM SYLVANIA, 71 Cherry Hill Drive, Beverly, MA 01915 (United States)

    2005-09-07

    Transparent ceramic materials with optical qualities comparable to single crystals of similar compositions have been developed in recent years, as a result of the improved understanding of powder-processing-fabrication- sintering-property inter-relationships. These high-temperature materials with a range of thermal and mechanical properties are candidate envelopes for focused-beam, short-arc lamps containing various fills operating at temperatures higher than quartz. This paper reviews the composition, structure and properties of transparent ceramic lamp envelope materials including sapphire, small-grained polycrystalline alumina, aluminium oxynitride, yttrium aluminate garnet, magnesium aluminate spinel and yttria-lanthana. A satisfactory thermal shock resistance is required for the ceramic tube to withstand the rapid heating and cooling cycles encountered in lamps. Thermophysical properties, along with the geometry, size and thickness of a transparent ceramic tube, are important parameters in the assessment of its resistance to fracture arising from thermal stresses in lamps during service. The corrosive nature of lamp-fill liquid and vapour at high temperatures requires that all lamp components be carefully chosen to meet the target life. The wide range of new transparent ceramics represents flexibility in pushing the limit of envelope materials for improved beamer lamps.

  5. Sudden change of quadrupole moment between the first 5/2- states of 197Hg and 199Hg

    International Nuclear Information System (INIS)

    Herzog, P.; Krien, K.; Freitag, M.; Reuschenbach, M.; Walitzki, H.

    1980-01-01

    Low-temperature time differential perturbed angular correlation experiments with the 164 KeV-134 keV cascade of sup(197m)Hg in a zinc matrix give evidence that the hitherto accepted value of the quadrupole moment of the first 5/2 - state of 197 Hg is erroneous. A new value is derived from a time differential perturbed angular correlation experiment with the 374 keV-158 keV cascade of sup(199m)Hg implanted into a Be single crystal and comparison with an analogous experiment for sup(197m)Hg. Taking Q(5/2 - , 199 Hg) = +0.95(7) b we derive Q(5/2 - , 197 Hg) = 0.081(6) b. This change of quadrupole moment is discussed in the framework of the shell model. (orig.)

  6. Low field magnetoresistance in a 2D topological insulator based on wide HgTe quantum well.

    Science.gov (United States)

    Olshanetsky, E B; Kvon, Z D; Gusev, G M; Mikhailov, N N; Dvoretsky, S A

    2016-09-01

    Low field magnetoresistance is experimentally studied in a two-dimensional topological insulator (TI) in both diffusive and quasiballistic samples fabricated on top of a wide (14 nm) HgTe quantum well. In all cases a pronounced quasi-linear positive magnetoresistance is observed similar to that found previously in diffusive samples based on a narrow (8 nm) HgTe well. The experimental results are compared with the main existing theoretical models based on different types of disorder: sample edge roughness, nonmagnetic disorder in an otherwise coherent TI and metallic puddles due to locally trapped charges that act like local gate on the sample. The quasiballistic samples with resistance close to the expected quantized values also show a positive low-field magnetoresistance but with a pronounced admixture of mesoscopic effects.

  7. 46 CFR 53.01-10 - Service restrictions and exceptions (replaces HG-101).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Service restrictions and exceptions (replaces HG-101... ENGINEERING HEATING BOILERS General Requirements § 53.01-10 Service restrictions and exceptions (replaces HG... lieu of the requirements in HG-101 of section IV of the ASME Boiler and Pressure Vessel Code...

  8. Note: Measuring breakdown characteristics during the hot re-ignition of high intensity discharge lamps using high frequency alternating current voltage.

    Science.gov (United States)

    van den Bos, R A J M; Sobota, A; Manders, F; Kroesen, G M W

    2013-04-01

    To investigate the cold and hot re-ignition properties of High Intensity Discharge (HID) lamps in more detail an automated setup was designed in such a way that HID lamps of various sizes and under different background pressures can be tested. The HID lamps are ignited with a ramped sinusoidal voltage signal with frequencies between 60 and 220 kHz and with amplitude up to 7.5 kV. Some initial results of voltage and current measurements on a commercially available HID lamp during hot and cold re-ignition are presented.

  9. Iodine laser of high efficiency and fast repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Hohla, K; Witte, K J

    1976-07-01

    The scaling laws of an iodine laser of high efficiency and fast repetition rate are reported. The laser is pumped with a new kind of low pressure Hg-UV-lamps which convert 32% of the electrical input in UV-light in the absorption band of the iodine laser and which can be fired up to 100 Hz. Details of a 10 kJ/1 nsec system as dimensions, energy density, repetition rate, flow velocity, gas composition and gas pressure and the overall efficiency are given which is expected to be about 2%.

  10. Competition between convection and diffusion in a metal halide lamp, investigated by numerical simulations and imaging laser absorption spectroscopy

    NARCIS (Netherlands)

    Beks, M.L.; Flikweert, A.J.; Nimalasuriya, T.; Stoffels, W.W.; Mullen, van der J.J.A.M.

    2008-01-01

    The effect of the competition between convection and diffusion on the distribution of metal halide additives in a high pressure mercury lamp has been examined by placing COST reference lamps with mercury fillings of 5 and 10 mg in a centrifuge. By subjecting them to different accelerational

  11. There are Many Kinds and Brands of TL Lamp and Ballast Transformer in the Market

    International Nuclear Information System (INIS)

    Koes-Indrakoesoema; Yayan-Andryanto

    2006-01-01

    However, there is still a problem of how to determining the power factor (cos φ) for one of brand of lamp. Lamps with low power factor will consume relatively high reactive power, hence the active power that can be utilized decreases. One of the effort that can be done to improve the level of the lamp's power factor is to install a suitable capacitor with the lamp. The values of the lamp's power factor of a certain brand of lamp will be different if the lamp is connected with different brand of ballast transformer. Therefore, the value of the capacitor that have to be installed to the lamp also must be different depend on the brand of the transformer. This experiment using 2 (two) TL lamp i.e Chiyoda 40 Watt and Philip 36 Watt which has been installed with capacitor 3.6 μF and combination of ballast transformer Philips, National and Siemens and shows that increase the power factor until 0.95. (author)

  12. Low cost SCR lamp driver indicates contents of digital computer registers

    Science.gov (United States)

    Cliff, R. A.

    1967-01-01

    Silicon Controlled Rectifier /SCR/ lamp driver is adapted for use in integrated circuit digital computers where it indicates the contents of the various registers. The threshold voltage at which visual indication begins is very sharply defined and can be adjusted to suit particular system requirements.

  13. Influence of gas discharge parameters on emissions from a dielectric barrier discharge excited argon excimer lamp

    Directory of Open Access Journals (Sweden)

    Mike Collier

    2011-11-01

    Full Text Available A dielectric barrier discharge excited neutral argon (Ar I excimer lamp has been developed and characterised. The aim of this study was to develop an excimer lamp operating at atmospheric pressure that can replace mercury lamps and vacuum equipment used in the sterilisation of medical equipment and in the food industry. The effects of discharge gas pressure, flow rate, excitation frequency and pulse width on the intensity of the Ar I vacuum ultraviolet (VUV emission at 126 nm and near infrared (NIR lines at 750.4 nm and 811.5 nm have been investigated. These three lines were chosen as they represent emissions resulting from de-excitation of excimer states that emit energetic photons with an energy of 9.8 eV. We observed that the intensity of the VUV Ar2* excimer emission at 126 nm increased with increasing gas pressure, but decreased with increasing excitation pulse frequency and pulse width. In contrast, the intensities of the NIR lines decreased with increasing gas pressure and increased with increasing pulse frequency and pulse width. We have demonstrated that energetic VUV photons of 9.8 eV can be efficiently generated in a dielectric barrier discharge in Ar.

  14. Low Systolic Blood Pressure and Mortality From All Causes and Vascular Diseases Among Older Middle-aged Men: Korean Veterans Health Study

    Directory of Open Access Journals (Sweden)

    Sang-Wook Yi

    2015-03-01

    Full Text Available Objectives: Recently, low systolic blood pressure (SBP was found to be associated with an increased risk of death from vascular diseases in a rural elderly population in Korea. However, evidence on the association between low SBP and vascular diseases is scarce. The aim of this study was to prospectively examine the association between low SBP and mortality from all causes and vascular diseases in older middle-aged Korean men. Methods: From 2004 to 2010, 94 085 Korean Vietnam War veterans were followed-up for deaths. The adjusted hazard ratios (aHR were calculated using the Cox proportional hazard model. A stratified analysis was conducted by age at enrollment. SBP was self-reported by a postal survey in 2004. Results: Among the participants aged 60 and older, the lowest SBP (<90 mmHg category had an elevated aHR for mortality from all causes (aHR, 1.9; 95% confidence interval [CI], 1.2 to 3.1 and vascular diseases (International Classification of Disease, 10th revision, I00-I99; aHR, 3.2; 95% CI, 1.2 to 8.4 compared to those with an SBP of 100 to 119 mmHg. Those with an SBP below 80 mmHg (aHR, 4.5; 95% CI, 1.1 to 18.8 and those with an SBP of 80 to 89 mmHg (aHR, 3.1; 95% CI, 0.9 to 10.2 also had an increased risk of vascular mortality, compared to those with an SBP of 90 to 119 mmHg. This association was sustained when excluding the first two years of follow-up or preexisting vascular diseases. In men younger than 60 years, the association of low SBP was weaker than that in those aged 60 years or older. Conclusions: Our findings suggest that low SBP (<90 mmHg may increase vascular mortality in Korean men aged 60 years or older.

  15. Evaluation of a mindfulness-based intervention program to decrease blood pressure in low-income African-American older adults.

    Science.gov (United States)

    Palta, Priya; Page, G; Piferi, R L; Gill, J M; Hayat, M J; Connolly, A B; Szanton, S L

    2012-04-01

    Hypertension affects a large proportion of urban African-American older adults.While there have been great strides in drug development, many older adults do not have access to such medicines or do not take them. Mindfulness-based stress reduction (MBSR)has been shown to decrease blood pressure in some populations. This has not been tested in low-income, urban African-American older adults. Therefore, the primary purpose of this pilot study was to test the feasibility and acceptability of a mindfulness-based program for low income, minority older adults provided in residence. The secondary purpose was to learn if the mindfulness-based program produced differences in blood pressure between the intervention and control groups. Participants were at least 62 years old and residents of a low-income senior residence. All participants were African-American, and one was male.Twenty participants were randomized to the mindfulness-based intervention or a social support control group of the same duration and dose. Blood pressure was measured with the Omron automatic blood pressure machine at baseline and at the end of the 8-week intervention. A multivariate regression analysis was performed on the difference in scores between baseline and post-intervention blood pressure measurements, controlling for age,education, smoking status, and anti-hypertensive medication use. Effect sizes were calculated to quantify the magnitude of the relationship between participation in the mindfulness-based intervention and the outcome variable, blood pressure. Attendance remained 980%in all 8 weeks of both the intervention and the control groups. The average systolic blood pressure decreased for both groups post-intervention. Individuals in the intervention group exhibited a 21.92-mmHg lower systolic blood pressure compared to the social support control group post-intervention and this value was statistically significant(p=0.020). The average diastolic blood pressure decreased in the

  16. Materials for incandescent and fluorescent lamps

    DEFF Research Database (Denmark)

    Thorsen, Knud Aage

    1996-01-01

    The article gives an overview of the materials systems used for incandescent lamps as well as a brief introduction to the systems used for fluorescent lamps. The materials used for incandescent lamps are doped tungsten used for the filaments, metals and alloys used for terminal and support posts......, lead wires and internal reflectors and screens as well as glasses for the envelope. The physics of bulbs and changes in bulbs during use are elucidated. The cost and energy savings and environmental benefits by replacement of incandescent lamps by fluorescent lamps are presented....

  17. Study of the odd mass transition nuclei: 185Hg, 187Hg, 189Hg and 183Ir

    International Nuclear Information System (INIS)

    Zerrouki, A.

    1979-01-01

    The radioactive decay of 185 Tl, 186 Tl, 187 Tl has been studied on the isotope separator Isocele II working on line with the Orsay synchrocyclotron from Au( 3 He,xn) reactions: the emitted α lines have been measured and the main γ lines belonging to the 187 Tl→ 187 Hg decay have been identified. The 185 Hg, 187 Hg, 189 Hg high spin states have been studied using the following (HI,xn) reactions obtained on the Strasbourg MP Tandem: 168 Er( 24 Mg,xn) 187 Hg, 188 Hg, 166 Er( 24 Mg,xn) 185 Hg, 186 Hg, 157 Gd( 32 S,xn) 184 Hg, 185 Hg, 158 Gd( 32 S,5n) 185 Hg and 175 Lu( 19 F,5n) 189 Hg. The excitation functions are indicated and a high spin level scheme of 189 Hg is proposed: it is compared to the 'quasiparticle + triaxial rotor' model predictions. A level scheme of 183 Ir is proposed from the data collected at Isolde II (CERN) by Dr. SCHUCK: it is analysed within the framework of the same theoretical model used above [fr

  18. Does chocolate reduce blood pressure? A meta-analysis.

    Science.gov (United States)

    Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P

    2010-06-28

    Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment groups, and interventions ran for 2 to 18 weeks. Meta-regression analysis found study design and type of control to be borderline significant but possibly indirect predictors

  19. Wood's lamp illumination (image)

    Science.gov (United States)

    A Wood's lamp emits ultraviolet light and can be a diagnostic aid in determining if someone has a fungal ... is an infection on the area where the Wood's lamp is illuminating, the area will fluoresce. Normally ...

  20. Prospective assessment of the frequency of low gradient severe aortic stenosis with preserved left ventricular ejection fraction: Critical impact of aortic flow misalignment and pressure recovery phenomenon.

    Science.gov (United States)

    Ringle, Anne; Castel, Anne-Laure; Le Goffic, Caroline; Delelis, François; Binda, Camille; Bohbot, Yohan; Ennezat, Pierre Vladimir; Guerbaai, Raphaëlle A; Levy, Franck; Vincentelli, André; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre

    2018-02-10

    The frequency of paradoxical low-gradient severe aortic stenosis (AS) varies widely across studies. The impact of misalignment of aortic flow and pressure recovery phenomenon on the frequency of low-gradient severe AS with preserved left ventricular ejection fraction (LVEF) has not been evaluated in prospective studies. To investigate prospectively the impact of aortic flow misalignment by Doppler and lack of pressure recovery phenomenon correction on the frequency of low-gradient (LG) severe aortic stenosis (AS) with preserved LVEF. Aortic jet velocities and mean pressure gradient (MPG) were obtained by interrogating all windows in 68 consecutive patients with normal LVEF and severe AS (aortic valve area [AVA] ≤1cm 2 ) on the basis of the apical imaging window alone (two-dimensional [2D] apical approach). Patients were classified as having LG or high-gradient (HG) AS according to MPG 35mL/m 2 or ≤35mL/m 2 , on the basis of the 2D apical approach, the multiview approach (multiple windows evaluation) and AVA corrected for pressure recovery. The proportion of LG severe AS was 57% using the 2D apical approach alone. After the multiview approach and correction for pressure recovery, the proportion of LG severe AS decreased from 57% to 13% (LF-LG severe AS decreased from 23% to 3%; NF-LG severe AS decreased from 34% to 10%). As a result, 25% of patients were reclassified as having HG severe AS (AVA ≤1cm 2 and MPG ≥40mmHg) and 19% as having moderate AS. Hence, 77% of patients initially diagnosed with LG severe AS did not have "true" LG severe AS when the multiview approach and the pressure recovery phenomenon correction were used. Aortic flow misevaluation, resulting from lack of use of multiple windows evaluation and pressure recovery phenomenon correction, accounts for a large proportion of incorrectly graded AS and considerable overestimation of the frequency of LG severe AS with preserved LVEF. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  1. Relationship between medical compression and intramuscular pressure as an explanation of a compression paradox.

    Science.gov (United States)

    Uhl, J-F; Benigni, J-P; Cornu-Thenard, A; Fournier, J; Blin, E

    2015-06-01

    Using standing magnetic resonance imaging (MRI), we recently showed that medical compression, providing an interface pressure (IP) of 22 mmHg, significantly compressed the deep veins of the leg but not, paradoxically, superficial varicose veins. To provide an explanation for this compression paradox by studying the correlation between the IP exerted by medical compression and intramuscular pressure (IMP). In 10 legs of five healthy subjects, we studied the effects of different IPs on the IMP of the medial gastrocnemius muscle. The IP produced by a cuff manometer was verified by a Picopress® device. The IMP was measured with a 21G needle connected to a manometer. Pressure data were recorded in the prone and standing positions with cuff manometer pressures from 0 to 50 mmHg. In the prone position, an IP of less than 20 did not significantly change the IMP. On the contrary, a perfect linear correlation with the IMP (r = 0.99) was observed with an IP from 20 to 50 mmHg. We found the same correlation in the standing position. We found that an IP of 22 mmHg produced a significant IMP increase from 32 to 54 mmHg, in the standing position. At the same time, the subcutaneous pressure is only provided by the compression device, on healthy subjects. In other words, the subcutaneous pressure plus the IP is only a little higher than 22 mmHg-a pressure which is too low to reduce the caliber of the superficial veins. This is in accordance with our standing MRI 3D anatomical study which showed that, paradoxically, when applying low pressures (IP), the deep veins are compressed while the superficial veins are not. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. SEM investigation of incandescent lamp mantle structure on durability

    International Nuclear Information System (INIS)

    Gerneke, D.; Lang, C.

    2002-01-01

    Full text: The incandescent mantle as used on pressure and non-pressure liquid fuel lamps has been in use for over 100 years. What remains unexplained is the way in which the resistance to mechanical shock and the decline in tensile strength with usage is experienced. It has been suggested that to improve durability it is necessary to continuously burn a new mantle for the first two to three hours. The known factors in mantle durability and mechanical strength are chemical composition and fabric weave. This study was undertaken to investigate the effects of burning time and temperature on thorium oxide mantles. The operating temperature of mantles on a range of kerosene pressure lamps was measured and found to be between 800 and 1100 deg C. Heat treatments of thorium based Coleman mantles were carried out in a laboratory furnace within these ranges of temperatures for periods ranging from 2 minutes to 2 hours. The mantles were then viewed in a LEO S440 analytical SEM. Results at 800 deg C show a distinct change in surface morphology with increasing exposure time. At the shorter times (2-5 minutes) the surface was relatively smooth. With increased time periods (15 - 120 minutes) the surface was observed to have a large lumpy structure. At 1100 deg C the difference in surface morphology was not apparent between the shortest and longest times. The surface appears much smoother and no lumpy structure was observed. This suggests that when a mantle is operated at the higher temperature of 1100 deg C the structure of the Thorium oxide is quickly transformed into the known stronger amorphous form. This is taken as the observed smooth structure seen in the SEM images of the 1100 deg C samples. Thus the mantle is expected to be more resistant to mechanical shock and have increased durability. Practical field test results confirm these observations. The mantle on a lamp that is operating efficiently, burns brightly, will far outlast a mantle on an inefficient lamp which bums

  3. Determinants of systemic zero-flow arterial pressure.

    Science.gov (United States)

    Brunner, M J; Greene, A S; Sagawa, K; Shoukas, A A

    1983-09-01

    Thirteen pentobarbital-anesthetized dogs whose carotid sinuses were isolated and perfused at a constant pressure were placed on total cardiac bypass. With systemic venous pressure held at 0 mmHg (condition 1), arterial inflow was stopped for 20 s at intrasinus pressures of 50, 125, and 200 mmHg. Zero-flow arterial pressures under condition 1 were 16.2 +/- 1.3 (SE), 13.8 +/- 1.1, and 12.5 +/- 0.8 mmHg, respectively. In condition 2, the venous outflow tube was clamped at the instant of stopping the inflow, causing venous pressure to rise. The zero-flow arterial pressures were 19.7 +/- 1.3, 18.5 +/- 1.4, and 16.4 +/- 1.2 mmHg for intrasinus pressures of 50, 125, and 200 mmHg, respectively. At all levels of intrasinus pressure, the zero-flow arterial pressure in condition 2 was higher (P less than 0.005) than in condition 1. In seven dogs, at an intrasinus pressure of 125 mmHg, epinephrine increased the zero-flow arterial pressure by 3.0 mmHg, whereas hexamethonium and papaverine decreased the zero-flow arterial pressure by 2 mmHg. Reductions in the hematocrit from 52 to 11% resulted in statistically significant changes (P less than 0.01) in zero-flow arterial pressures. Thus zero-flow arterial pressure was found to be affected by changes in venous pressure, hematocrit, and vasomotor tone. The evidence does not support the literally interpreted concept of the vascular waterfall as the model for the finite arteriovenous pressure difference at zero flow.

  4. BMI mediates the association between low educational level and higher blood pressure during pregnancy in Japan.

    Science.gov (United States)

    Jwa, Seung Chik; Fujiwara, Takeo; Hata, Akira; Arata, Naoko; Sago, Haruhiko; Ohya, Yukihiro

    2013-04-25

    Research investigating the association between socioeconomic status (SES) and blood pressure (BP) during pregnancy is limited and its underlying pathway is unknown. The aim of this study was to investigate the mediators of the association between educational level as an indicator of the SES and BP in early and mid-pregnancy among Japanese women. Nine hundred and twenty-three pregnant women in whom BP was measured before 16 weeks and at 20 weeks of gestation were enrolled in this study. Maternal educational levels were categorized into three groups: high (university or higher), mid (junior college), and low (junior high school, high school, or vocational training school). The low educational group had higher systolic (low vs. high, difference = 2.39 mmHg, 95% confidence interval [CI]: 0.59 to 4.19) and diastolic BP levels (low vs. high, difference = 0.74 mmHg, 95% CI: -0.52 to 1.99) in early pregnancy. However, the same associations were not found after adjustment for pre-pregnancy body mass index (BMI). BP reduction was observed in mid-pregnancy in all three educational groups and there was no association between educational level and pregnancy-induced hypertension. In Japanese women, the low educational group showed higher BP during pregnancy than the mid or high educational groups. Pre-pregnancy BMI mediates the association between educational level and BP.

  5. Lysosome-Associated Membrane Proteins (LAMP Maintain Pancreatic Acinar Cell Homeostasis: LAMP-2–Deficient Mice Develop PancreatitisSummary

    Directory of Open Access Journals (Sweden)

    Olga A. Mareninova

    2015-11-01

    Full Text Available Background & Aims: The pathogenic mechanism of pancreatitis is poorly understood. Recent evidence implicates defective autophagy in pancreatitis responses; however, the pathways mediating impaired autophagy in pancreas remain largely unknown. Here, we investigate the role of lysosome associated membrane proteins (LAMPs in pancreatitis. Methods: We analyzed changes in LAMPs in experimental models and human pancreatitis, and the underlying mechanisms: LAMP deglycosylation and degradation. LAMP cleavage by cathepsin B (CatB was analyzed by mass spectrometry. We used mice deficient in LAMP-2 to assess its role in pancreatitis. Results: Pancreatic levels of LAMP-1 and LAMP-2 greatly decrease across various pancreatitis models and in human disease. Pancreatitis does not trigger the LAMPs’ bulk deglycosylation but induces their degradation via CatB-mediated cleavage of the LAMP molecule close to the boundary between luminal and transmembrane domains. LAMP-2 null mice spontaneously develop pancreatitis that begins with acinar cell vacuolization due to impaired autophagic flux, and progresses to severe pancreas damage characterized by trypsinogen activation, macrophage-driven inflammation, and acinar cell death. LAMP-2 deficiency causes a decrease in pancreatic digestive enzymes content, and stimulates the basal and inhibits cholecystokinin-induced amylase secretion by acinar cells. The effects of LAMP-2 knockout and acute cerulein pancreatitis overlap, which corroborates the pathogenic role of LAMP decrease in experimental pancreatitis models. Conclusions: The results indicate a critical role for LAMPs, particularly LAMP-2, in maintaining pancreatic acinar cell homeostasis and provide evidence that defective lysosomal function, resulting in impaired autophagy, leads to pancreatitis. Mice with LAMP-2 deficiency present a novel genetic model of human pancreatitis caused by lysosomal/autophagic dysfunction. Keywords: Amylase Secretion, Autophagy

  6. Diode-laser-illuminated automotive lamp systems

    Science.gov (United States)

    Marinelli, Michael A.; Remillard, Jeffrey T.

    1998-05-01

    We have utilized the high brightness of state-of-the-art diode laser sources, and a variety of emerging optical technologies to develop a new class of thin, uniquely styled automotive brake and signal lamps. Using optics based on thin (5 mm) plastic sheets, these lamps provide appearance and functional advantages not attainable with traditional automotive lighting systems. The light is coupled into the sheets using a 1 mm diameter glass fiber, and manipulated using refraction and reflection from edges, surfaces, and shaped cut-outs. Light can be extracted with an efficiency of approximately 50% and formed into a luminance distribution that meets the Society of Automotive Engineers (SAE) photometric requirements. Prototype lamps using these optics have been constructed and are less than one inch in thickness. Thin lamps reduce sheet metal costs, complexity, material usage, weight, and allow for increased trunk volume. In addition, these optics enhance lamp design flexibility. When the lamps are not energized, they can appear body colored, and when lighted, the brightness distribution across the lamp can be uniform or structured. A diode laser based brake lamp consumes seven times less electrical power than one using an incandescent source and has instant on capability. Also, diode lasers have the potential to be 10-year/150,000 mile light sources.

  7. Photodegradation of HCFC-22 Using Microwave Discharge Electrodeless Mercury Lamp with TiO2 Photocatalyst Balls

    Directory of Open Access Journals (Sweden)

    Seong-Gyu Seo

    2014-01-01

    Full Text Available The photodegradation of chlorodifluoromethane (HCFC-22 was investigated using microwave/UV/TiO2 photocatalysts hybrid system. The microwave discharge electrodeless mercury lamp (MDEML used in this study showed mainly atomic Hg emission lines at 253.7 nm. The decomposition efficiency of HCFC-22 increased with decreasing inlet concentration and with increasing reactor residence time. The removal efficiency increased with increasing microwave power on every oxygen concentration. The highest degradation efficiency was obtained when both TiO2 balls and MDEML were used.

  8. Model of discharge lamps with magnetic ballast

    OpenAIRE

    Molina, Julio; Sainz Sapera, Luis; Mesas García, Juan José; Bergas Jané, Joan Gabriel

    2013-01-01

    Magnetic ballast discharge lamp modeling has been extensively studied because these lamps can be an important source of harmonics. Discharge lamp models usually represent the arc voltage by a square waveform. However, this waveform can be far from actual arc voltages, which affects the accuracy of the lamp models. This paper investigates the actual arc voltage behavior of discharge lamps from laboratory measurements and proposes a novel characterization of these voltages to reformulate the co...

  9. Does chocolate reduce blood pressure? A meta-analysis

    Directory of Open Access Journals (Sweden)

    Ried Karin

    2010-06-01

    Full Text Available Abstract Background Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. Methods We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive. Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P Results Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change ± SE: SBP: -3.2 ± 1.9 mmHg, P = 0.001; DBP: -2.0 ± 1.3 mmHg, P = 0.003. However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 ± 3.0 mmHg; P = 0.0009; DBP: -2.7 ± 2.2 mm Hg, P = 0.01, while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 ± 2.3 mmHg, P = 0.17; DBP: -1.3 ± 1.6 mmHg, P = 0.12. Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30

  10. Exaggerated exercise blood pressure response in middle-aged men as a predictor of future blood pressure: a 10-year follow-up.

    Science.gov (United States)

    Ito, Katsuyuki; Iwane, Masataka; Miyai, Nobuyuki; Uchikawa, Yukiko; Mugitani, Koichi; Mohara, Osamu; Shiba, Mitsuru; Arita, Mikio

    The prognostic value of an exaggerated exercise systolic blood pressure response (EESBPR) remains controversial. This study was designed to assess whether an EESBPR is associated with the predictor of future blood pressure. From an initial population of 1,534 male-subjects with normal BP or no medication who underwent ergometric exercise, 733 subjects (mean age: 41 years old) at baseline to follow-up BP after an average of 10 years were selected. A 12-min exercise tolerance test with three phases of estimated load from predictive maximum oxygen intake was performed at baseline, and exercise BP was measured. Exercise BP response was classified by three group: Low group (G) (exercise SBP exercise BP:180-199 mmHg), High G (exercise BP:200 mmHg ≦). BP after 10 years in Low G was 123 ± 12/79 ± 7 mmHg, in Middle G:127 ± 13/81 ± 8 mmHg, in High G :134 ± 15/84 ± 10 mmHg. Compared with in Low G, BP after 10 years in High G significantly increased (p exercise SBP at baseline to BP after 10 years. In multivariate-adjusted models, the relationship of SBP at follow-up was stronger to exercise SBP (β = 0.271, P aged men, exercise SBP would be a stronger predictor of future SBP, DBP rather than BP at rest. In optimal of classification of BP (SBP exercise BP response was clearly associated with BP after 10 years.

  11. Capacitive discharge exciplex lamps

    Energy Technology Data Exchange (ETDEWEB)

    Sosnin, E A; Erofeev, M V; Tarasenko, V F [High Current Electronics Institute, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2005-09-07

    Simple-geometry exciplex lamps of a novel type excited by a capacitive discharge (CD-excilamps) have been investigated. An efficient radiation has been obtained on KrBr*, KrCl*, XeBr*, XeCl* molecules and I* atom. The highest values of efficiency of various working molecules are approximately 10-18%. The lifetime of the operating gas mixture in KrCl*, XeCl*, I* and XeBr* exciplex lamps excited by a CD is above 1000 h. Owing to the above-mentioned characteristics, the exciplex lamps excited by a CD are supposed to be very promising for various applications.

  12. Capacitive discharge exciplex lamps

    International Nuclear Information System (INIS)

    Sosnin, E A; Erofeev, M V; Tarasenko, V F

    2005-01-01

    Simple-geometry exciplex lamps of a novel type excited by a capacitive discharge (CD-excilamps) have been investigated. An efficient radiation has been obtained on KrBr*, KrCl*, XeBr*, XeCl* molecules and I* atom. The highest values of efficiency of various working molecules are approximately 10-18%. The lifetime of the operating gas mixture in KrCl*, XeCl*, I* and XeBr* exciplex lamps excited by a CD is above 1000 h. Owing to the above-mentioned characteristics, the exciplex lamps excited by a CD are supposed to be very promising for various applications

  13. Enhancement of laser-induced breakdown spectroscopy (LIBS) Detection limit using a low-pressure and short-pulse laser-induced plasma process.

    Science.gov (United States)

    Wang, Zhen Zhen; Deguchi, Yoshihiro; Kuwahara, Masakazu; Yan, Jun Jie; Liu, Ji Ping

    2013-11-01

    Laser-induced breakdown spectroscopy (LIBS) technology is an appealing technique compared with many other types of elemental analysis because of the fast response, high sensitivity, real-time, and noncontact features. One of the challenging targets of LIBS is the enhancement of the detection limit. In this study, the detection limit of gas-phase LIBS analysis has been improved by controlling the pressure and laser pulse width. In order to verify this method, low-pressure gas plasma was induced using nanosecond and picosecond lasers. The method was applied to the detection of Hg. The emission intensity ratio of the Hg atom to NO (IHg/INO) was analyzed to evaluate the LIBS detection limit because the NO emission (interference signal) was formed during the plasma generation and cooling process of N2 and O2 in the air. It was demonstrated that the enhancement of IHg/INO arose by decreasing the pressure to a few kilopascals, and the IHg/INO of the picosecond breakdown was always much higher than that of the nanosecond breakdown at low buffer gas pressure. Enhancement of IHg/INO increased more than 10 times at 700 Pa using picosecond laser with 35 ps pulse width. The detection limit was enhanced to 0.03 ppm (parts per million). We also saw that the spectra from the center and edge parts of plasma showed different features. Comparing the central spectra with the edge spectra, IHg/INO of the edge spectra was higher than that of the central spectra using the picosecond laser breakdown process.

  14. 49 CFR 234.221 - Lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be...

  15. Effects of low sodium diet versus high sodium diet on blood pressure, renin, aldosterone, catecholamines, cholesterol, and triglyceride.

    Science.gov (United States)

    Graudal, Niels Albert; Hubeck-Graudal, Thorbjorn; Jurgens, Gesche

    2017-04-09

    In spite of more than 100 years of investigations the question of whether a reduced sodium intake improves health is still unsolved. To estimate the effects of low sodium intake versus high sodium intake on systolic and diastolic blood pressure (SBP and DBP), plasma or serum levels of renin, aldosterone, catecholamines, cholesterol, high-density lipoprotein (HDL), low-density lipoprotein (LDL) and triglycerides. The Cochrane Hypertension Information Specialist searched the following databases for randomized controlled trials up to March 2016: the Cochrane Hypertension Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (2016, Issue 3), MEDLINE (from 1946), Embase (from 1974), the World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov. We also searched the reference lists of relevant articles. Studies randomising persons to low-sodium and high-sodium diets were included if they evaluated at least one of the above outcome parameters. Two review authors independently collected data, which were analysed with Review Manager 5.3. A total of 185 studies were included. The average sodium intake was reduced from 201 mmol/day (corresponding to high usual level) to 66 mmol/day (corresponding to the recommended level).The effect of sodium reduction on blood pressure (BP) was as follows: white people with normotension: SBP: mean difference (MD) -1.09 mmHg (95% confidence interval (CI): -1.63 to -0.56; P = 0.0001); 89 studies, 8569 participants; DBP: + 0.03 mmHg (MD 95% CI: -0.37 to 0.43; P = 0.89); 90 studies, 8833 participants. High-quality evidence. Black people with normotension: SBP: MD -4.02 mmHg (95% CI:-7.37 to -0.68; P = 0.002); seven studies, 506 participants; DBP: MD -2.01 mmHg (95% CI:-4.37 to 0.35; P = 0.09); seven studies, 506 participants. Moderate-quality evidence. Asian people with normotension: SBP: MD -0.72 mmHg (95% CI: -3.86 to 2.41; P = 0.65); DBP: MD -1.63 mmHg (95% CI:-3.35 to 0

  16. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  17. 30 CFR 57.17010 - Electric lamps.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric lamps. 57.17010 Section 57.17010 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE....17010 Electric lamps. Individual electric lamps shall be carried for illumination by all persons...

  18. Influence of Baseline Diastolic Blood Pressure on Effects of Intensive Compared With Standard Blood Pressure Control.

    Science.gov (United States)

    Beddhu, Srinivasan; Chertow, Glenn M; Cheung, Alfred K; Cushman, William C; Rahman, Mahboob; Greene, Tom; Wei, Guo; Campbell, Ruth C; Conroy, Margaret; Freedman, Barry I; Haley, William; Horwitz, Edward; Kitzman, Dalane; Lash, James; Papademetriou, Vasilios; Pisoni, Roberto; Riessen, Erik; Rosendorff, Clive; Watnick, Suzanne G; Whittle, Jeffrey; Whelton, Paul K

    2018-01-09

    In individuals with a low diastolic blood pressure (DBP), the potential benefits or risks of intensive systolic blood pressure (SBP) lowering are unclear. SPRINT (Systolic Blood Pressure Intervention Trial) was a randomized controlled trial that compared the effects of intensive (target baseline DBP. Mean baseline SBP and DBP were 139.7±15.6 and 78.1±11.9 mm Hg, respectively. Regardless of the randomized treatment, baseline DBP had a U-shaped association with the hazard of the primary cardiovascular disease outcome. However, the effects of the intensive SBP intervention on the primary outcome were not influenced by baseline DBP level ( P for interaction=0.83). The primary outcome hazard ratio for intensive versus standard treatment was 0.78 (95% confidence interval, 0.57-1.07) in the lowest DBP quintile (mean baseline DBP, 61±5 mm Hg) and 0.74 (95% confidence interval, 0.61-0.90) in the upper 4 DBP quintiles (mean baseline DBP, 82±9 mm Hg), with an interaction P value of 0.78. Results were similar for all-cause death and kidney events. Low baseline DBP was associated with increased risk of cardiovascular disease events, but there was no evidence that the benefit of the intensive SBP lowering differed by baseline DBP. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01206062. © 2017 American Heart Association, Inc.

  19. Spectral radiance of strong lines in positive column mercury discharges with argon carrier gas

    International Nuclear Information System (INIS)

    Sansonetti, Craig J; Reader, Joseph

    2006-01-01

    The spectral radiance of the 185 and 254 nm lines in two positive column mercury discharge lamps was measured over a wide range of operating conditions. The lamps had internal diameters of 5 and 23 mm. Argon was used as a carrier gas. The lamps were operated with cold spot temperatures of 20, 40 and 60 0 C. At each of these temperatures, results were obtained for five currents ranging from 20 to 100 mA for the 5 mm lamp and from 200 to 1000 mA for the 23 mm lamp. For each current studied, results were determined for argon pressures ranging from 66.6 to 666 Pa (0.5 to 5.0 Torr) in the 5 mm lamp and 26.6 to 666 Pa (0.2 to 5.0 Torr) in the 23 mm lamp. An argon miniarc was used as the radiometric standard. By calibrating the spectral response of the optical system with a well-characterized mercury pencil lamp, results were obtained for 12 additional Hg lines from 289 to 579 nm. For the 23 mm lamp the electric field in the positive column was measured. For this lamp the radiated power as a percentage of input power was also determined. The results provide an experimental basis for validating computer models of Hg fluorescent lamp discharges

  20. Lamps recycling aiming at the environment preservation

    International Nuclear Information System (INIS)

    Yamachita, Roberto Akira; Gama, Paulo Henrique R. Pereira; Haddad, Jamil; Santos, Afonso H. Moreira; Guardia, Eduardo C.

    1999-01-01

    The article discusses the following issues of lamps recycling in Brazil: mercury lamps recycling, recycling potential, energy conservation and environmental impacts, enterprises lamps recycling, and incentives policy

  1. Beryllium abundances in Hg-Mn stars

    International Nuclear Information System (INIS)

    Boesgaard, A.M.; Heacox, W.D.; Wolff, S.C.; Borsenberger, J.; Praderie, F.

    1982-01-01

    The Hg-Mn stars show anomalous line strengths of many chemical elements including Be. We have observed the Be ii resonance doublet at lambdalambda 3130, 3131 at 6.7 A mm -1 in 43 Hg-Mn stars and 10 normal stars in the same temperature range with the coude spectrograph of the 2.24 m University of Hawaii telescope at Mauna Kea. Measured equivalent widths of the two lines and/or the blend of the doublet have been compared with predictions from (1) LTE model atmospheres and (2) non-LTE line formation on non-LTE model atmospheres. (For strong Be ii lines, the LTE calculations result in more Be by factors of 2 to 4 than do the non-LTE calculations.) Overabundances of factors of 20--2 x 10 4 relative to solar have been found for 75% of the Hg-Mn stars. The 25% with little or no Be are typically among the cooler Hg-Mn stars, but for the stars with Be excesses, there is only marginal evidence for a correlationi of the size of the overabundance and temperature. It is suggested that diffusion driven by radiation pressure is responsible for the observed Be abundance anomalies

  2. [Changes in intraocular pressure depending on posture].

    Science.gov (United States)

    Barac, Ramona; Pop, Monica; Tătaru, C; Gheorghe, A; Bădescu, Silvia; Stanciu, Maria; Burcea, M

    2014-01-01

    Glaucoma is an important eye disease that, left untreated, causes irreversible blindness by affecting optic nerve threads. Decreasing intraocular pressure and maintaining it at a low level throughout the day is one of the objectives of antiglaucoma therapy. This is a prospective study conducted on a sample of 80 patients who presented at "Emergency Eye Hospital" Bucharest between 1st of December 2013 30th of July 2014. Patients were divided into two groups: 40 patients with glaucoma and 40 patients without glaucoma (control group). THE OBJECTIVE OF THE STUDY: To determine changes in intraocular pressure that may occur depending on body posture and the correlations between changes in intraocular pressure and glaucoma, obesity, hypertension. These IOP changes may be important in the progression of glaucoma regarding that one third of our time is spent on supine position during night. RESULTS AND CONCLUZIONS: IOP varies from sitting down to supine position. IOP increases in supine in most patients (with or without glaucoma) with an average of 1.25 mmHg. The increase among patients with glaucoma is higher (1.67 mmHg) compared to those without glaucoma (0.82 mmHg). In patients with hypertension and glaucoma, IOP increased with 2.62 mmHg. In patients with hypertension and obesity IOP increased with 2.5 mmHg.

  3. CALiPER Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-31

    This CALiPER report examines the characteristics of a subset of lamps from CALiPER Retail Lamps Study 3 in more detail. Specifically, it focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers.

  4. ASSOCIATION OF DAIRY CONSUMPTION AND 24-HOUR BLOOD PRESSURE IN OLDER ADULTS WITH HYPERTENSION.

    Science.gov (United States)

    Lana, Alberto; Banegas, Jose R; Guallar-Castillón, Pilar; Rodríguez-Artalejo, Fernando; Lopez-Garcia, Esther

    2018-05-25

    The aim was to examine the association between habitual consumption of dairy products and 24-h ambulatory blood pressure monitoring among older adults with hypertension. We conducted an analysis of 715 community-living hypertensive adults aged ≥60. Habitual dairy consumption was assessed with a validated diet history. Blood pressure was recorded by 24-hour ambulatory blood pressure monitoring; controlled blood pressure was defined as 24-hour blood pressure blood pressure 1.40 mm Hg higher (95% confidence interval: 0.01, 2.81) than consumers of blood pressure 1.74 mm Hg lower (95% confidence interval: -3.26, -0.23) than consumers of blood pressure was 1.83 (1.05-3.08) for those consuming ≥7 servings/wk of low-fat milk/yogurt, when comparing with consumers of blood pressure. Regular consumption of low-fat milk/yogurt was associated with lower 24-h diastolic blood pressure and with better blood pressure control among older adults with hypertension. Copyright © 2018. Published by Elsevier Inc.

  5. Secondary electron emission characteristics of oxide electrodes in flat electron emission lamp

    Directory of Open Access Journals (Sweden)

    Chang-Lin Chiang

    2016-01-01

    Full Text Available The present study concerns with the secondary electron emission coefficient, γ, of the cathode materials used in the newly developed flat electron emission lamp (FEEL devices, which essentially integrates the concept of using cathode for fluorescent lamp and anode for cathode ray tube (CRT to obtain uniform planar lighting. Three different cathode materials, namely fluorine-doped tin oxide (FTO, aluminum oxide coated FTO (Al2O3/FTO and magnesium oxide coated FTO (MgO/FTO were prepared to investigate how the variations of γ and working gases influence the performance of FEEL devices, especially in lowering the breakdown voltage and pressure of the working gases. The results indicate that the MgO/FTO bilayer cathode exhibited a relatively larger effective secondary electron emission coefficient, resulting in significant reduction of breakdown voltage to about 3kV and allowing the device to be operated at the lower pressure to generate the higher lighting efficiency.

  6. Secondary electron emission characteristics of oxide electrodes in flat electron emission lamp

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, Chang-Lin, E-mail: CLChiang@itri.org.tw; Li, Chia-Hung [Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4, Chung Hsing Road, Chutung 310, Taiwan (China); Department of Electrophysics, National Chiao Tung University, 1001 Ta Hsueh Road, Hsinchu 300, Taiwan (China); Zeng, Hui-Kai [Department of Electronic Engineering, Chung Yuan Christian University, 200 Chung Pei Road, Chung Li 320, Taiwan (China); Li, Jung-Yu, E-mail: JY-Lee@itri.org.tw; Chen, Shih-Pu; Lin, Yi-Ping [Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4, Chung Hsing Road, Chutung 310, Taiwan (China); Hsieh, Tai-Chiung; Juang, Jenh-Yih, E-mail: jyjuang@cc.nctu.edu.tw [Department of Electrophysics, National Chiao Tung University, 1001 Ta Hsueh Road, Hsinchu 300, Taiwan (China)

    2016-01-15

    The present study concerns with the secondary electron emission coefficient, γ, of the cathode materials used in the newly developed flat electron emission lamp (FEEL) devices, which essentially integrates the concept of using cathode for fluorescent lamp and anode for cathode ray tube (CRT) to obtain uniform planar lighting. Three different cathode materials, namely fluorine-doped tin oxide (FTO), aluminum oxide coated FTO (Al{sub 2}O{sub 3}/FTO) and magnesium oxide coated FTO (MgO/FTO) were prepared to investigate how the variations of γ and working gases influence the performance of FEEL devices, especially in lowering the breakdown voltage and pressure of the working gases. The results indicate that the MgO/FTO bilayer cathode exhibited a relatively larger effective secondary electron emission coefficient, resulting in significant reduction of breakdown voltage to about 3kV and allowing the device to be operated at the lower pressure to generate the higher lighting efficiency.

  7. Commercial Slit-Lamp Anterior Segment Photography versus Digital Compact Camera Mounted on a Standard Slit-Lamp with an Adapter.

    Science.gov (United States)

    Oliphant, Huw; Kennedy, Alasdair; Comyn, Oliver; Spalton, David J; Nanavaty, Mayank A

    2018-06-16

    To compare slit lamp mounted cameras (SLC) versus digital compact camera (DCC) with slit-lamp adaptor when used by an inexperienced technician. In this cross sectional study, where posterior capsule opacification (PCO) was used as a comparator, patients were consented for one photograph with SLC and two with DCC (DCC1 and DCC2), with a slit-lamp adaptor. An inexperienced clinic technician, who took all the photographs and masked the images, recruited one eye of each patient. Images were graded for PCO using ECPO2000 software by two independent masked graders. Repeatability between DCC1 & DCC2 and limits-of-agreement between SLC and DCC1 mounted on slit-lamp with an adaptor were assessed. Coefficient-of-repeatability and Bland-Altmann plots were analyzed. Seventy-two patients (eyes) were recruited in the study. First 9 patients (eyes) were excluded due to unsatisfactory image quality from both the systems. Mean EPCO score for SLC was 2.28 (95% CI: 2.09 -2.45), for DCC1 was 2.28 (95% CI: 2.11-2.45), and for the DCC2 was 2.11 (95% CI: 2.11-2.45). There was no significant difference in EPCO scores between SLC Vs. DCC1 (p = 0.98) and between DCC1 and DCC 2 (p = 0.97). Coefficient of repeatability between DCC images was 0.42, and the coefficient of repeatability between DCC and SLC was 0.58. DCC on slit-lamp with an adaptor is comparable to a SLC. There is an initial learning curve, which is similar for both for an inexperienced person. This opens up the possibility for low cost anterior segment imaging in the clinical, research and teaching settings.

  8. Spectroscopy on metal-halide lamps under varying gravity conditions

    NARCIS (Netherlands)

    Flikweert, A.J.

    2008-01-01

    Worldwide, 20% of all electricity is used for lighting. For this reason, efficient lamps are economically and ecologically important. High intensity discharge (HID) lamps are efficient lamps. The most common HID lamp these days is the metal-halide (MH) lamp. MH lamps have a good colour rendering

  9. Evaluation of the effect of systolic blood pressure and pulse pressure on cognitive function: the Women's Health and Aging Study II.

    Directory of Open Access Journals (Sweden)

    Sevil Yasar

    Full Text Available Evidence suggests that elevated systolic blood pressure (SBP and pulse pressure (PP in midlife is associated with increased risk for cognitive impairment later in life. There is mixed evidence regarding the effects of late life elevated SBP or PP on cognitive function, and limited information on the role of female gender.Effects of SBPand PPon cognitive abilities at baseline and over a 9-year period were evaluated in 337 non-demented community-dwelling female participants over age 70 in the Women's Health and Aging Study II using logistic and Cox proportional hazards regression analyses. Participants aged 76-80 years with SBP≥160 mmHg or PP≥84 mmHg showed increased incidence of impairment on Trail Making Test-Part B (TMT, Part B, a measure of executive function, over time when compared to the control group that included participants with normal and pre-hypertensive SBP (<120 and 120-139 mmHg or participants with low PP (<68 mmHg (HR = 5.05 [95%CI = 1.42, 18.04], [HR = 5.12 [95%CI = 1.11; 23.62], respectively. Participants aged 70-75 years with PP≥71 mmHg had at least a two-fold higher incidence of impairment on HVLT-I, a measure of verbal learning, over time when compared to participants with low PP (<68 mmHg (HR = 2.44 [95%CI = 1.11, 5.39].Our data suggest that elevated SBP or PP in older non-demented women increases risk for late-life cognitive impairment and that PP could be used when assessing the risk for impairment in cognitive abilities. These results warrant further, larger studies to evaluate possible effects of elevated blood pressure in normal cognitive aging.

  10. Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study.

    Science.gov (United States)

    Head, Geoffrey A; Mihailidou, Anastasia S; Duggan, Karen A; Beilin, Lawrence J; Berry, Narelle; Brown, Mark A; Bune, Alex J; Cowley, Diane; Chalmers, John P; Howe, Peter R C; Hodgson, Jonathan; Ludbrook, John; Mangoni, Arduino A; McGrath, Barry P; Nelson, Mark R; Sharman, James E; Stowasser, Michael

    2010-04-14

    Twenty-four hour ambulatory blood pressure thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood pressure thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood pressure equivalents to clinic blood pressure thresholds for diagnosis and treatment of hypertension. We collated 24 hour ambulatory blood pressure data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood pressure measured by trained staff and in a smaller cohort by doctors (n=1693). Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood pressure 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood pressure and 10/5 mm Hg higher than 24 hour blood pressure, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/1 mm Hg lower in older people compared with the combined group. Our study provides daytime ambulatory blood pressure thresholds that are slightly lower than equivalent clinic values. Clinic blood pressure measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood pressure values.

  11. Mechanism of conductivity type conversion in p-Hg1-xCdxTe crystals under low energy ion bombardment

    International Nuclear Information System (INIS)

    Bogoboyashchij, V.V.; Izhnin, I.I.

    2000-01-01

    Conditions giving rise to accelerated diffusion of Hg under bombardment of p-Hg 1-x Cd x Te by low-energy particles are analyzed and probable mechanisms of the phenomenon are suggested, permitting qualitative and quantitative agreement with experimental data. Analysis indicates that basic regularities of p-n-conversion during Hg 0.8 Cd 0.2 Te crystal bombardment by neutralized ions can be easily explained in the framework of traditional notions of mercury chemical diffusion in this material. The regularities stem from specific features of defect formation in Hg 0.8 Cd 0.2 Te, on the one hand, and from a high concentration of intrinsic electrons and holes, screening effectively the defective layer electric field, on the other hand. The high rate of conversion during ion bombardment compared with the rate of conversion during annealing in mercury vapors can be explained by the fact that a great number of nonequilibrium interstitial atoms of mercury, by far exceeding the value during thermal annealing, is crated near the surface of the crystal bombarded [ru

  12. CALiPER Retail Lamps Study 3

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Beeson, Tracy A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-02-01

    The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvement was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other

  13. Red-free light for measurement of intraocular pressure using Goldmann applanation tonometer without fluorescein.

    Science.gov (United States)

    Ghoneim, Ehab M

    2014-01-01

    To evaluate the use of red-free light for the measurement of intraocular pressure (IOP) using a Goldmann applanation tonometer without fluorescein. This cross-sectional study was carried out on 500 eyes in 250 patients attending the Ophthalmology Outpatient Clinic at Suez Canal University Hospital. The IOP was measured using a Goldmann applanation tonometer mounted on a Haag-Streit slit-lamp. The measurements were performed first using red-free light without fluorescein. Then the measurements were repeated with cobalt blue light and topical fluorescein on the same eyes. The mean IOP was 15.23 ± 3.3 (SD) mm Hg using the red-free light without fluorescein, whereas it was 15.78 ± 3.7 (SD) mm Hg when measured using cobalt blue light after the application of fluorescein to the conjunctival sac. This difference was not statistically significant. Measurement of IOP with a Goldmann applanationtonometer with red-free light and without the use of fluorescein is simple, saves time, and gives an accurate IOP measurement relative to the traditional measurement technique with cobalt blue light and topical fluorescein.

  14. Atmospheric-pressure plasma technology

    International Nuclear Information System (INIS)

    Kogelschatz, U

    2004-01-01

    Major industrial plasma processes operating close to atmospheric pressure are discussed. Applications of thermal plasmas include electric arc furnaces and plasma torches for generation of powders, for spraying refractory materials, for cutting and welding and for destruction of hazardous waste. Other applications include miniature circuit breakers and electrical discharge machining. Non-equilibrium cold plasmas at atmospheric pressure are obtained in corona discharges used in electrostatic precipitators and in dielectric-barrier discharges used for generation of ozone, for pollution control and for surface treatment. More recent applications include UV excimer lamps, mercury-free fluorescent lamps and flat plasma displays

  15. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  16. Analysis of the performance of domestic lighting lamps

    International Nuclear Information System (INIS)

    Aman, M.M.; Jasmon, G.B.; Mokhlis, H.; Bakar, A.H.A.

    2013-01-01

    The power crisis problem is getting worse in the developing countries. Measures are being taken to overcome the power shortage problem by efficiently utilizing the available power. Replacement of high-power consumption lamps with energy efficient lamps is also among these steps. This paper presents a detailed comparative analysis between domestic lighting lamps (DLLs) use for producing artificial light. DLLs include incandescent lamp (IL), fluorescent lamp (FL) and compact fluorescent lamp (CFL). Light emitting diodes (LED) based lamp technology is relatively new in comparison with conventional incandescent and discharge lamps. However, the present study will also cover the LED lamps. Power quality based experiments have been conducted on DLLs in Power System Laboratory and power consumption based calculations are carried out using the lighting design software DIALux. The result shows that with the current technology, the use of FL and LED lamp is beneficial for utility as well as for consumer. However, with the current pace in the development of LED technology, it is possible LED lamps will lead the lighting market in the near future. The paper has also presented the uncertainties that exist in lighting market and proposed the guidelines that will help in making future energy policy. - Highlights: ► Performances of domestic lighting lamps are compared. ► Power quality and power consumption based case study results are presented. ► For future energy policies, recommendations are also given.

  17. Medium pressure mercury discharge for use as an intense white light source

    International Nuclear Information System (INIS)

    Kitsinelis, S; Devonshire, R; Stone, D A; Tozer, R C

    2005-01-01

    In this paper, we demonstrate the possibilities that exist in developing a high brightness white light source. The lamp employs mercury at a few Torr and is operated with short pulses of the order of 1 μs at a frequency of 10 kHz. The emission spectrum is atomic in nature and the white light is the outcome of a relative enhancement of the mercury yellow lines at 577 and 579 nm with respect to the rest of the visible lines, which shifts the colour coordinates of the source towards the black body locus of the chromaticity diagram. The pulse operation of a lamp containing mercury at a vapour pressure of 20 Torr offers a greater near-UV and visible output compared to a phosphor-uncoated, low-pressure pulsed compact mercury discharge

  18. Inductive tuners for microwave driven discharge lamps

    Science.gov (United States)

    Simpson, James E.

    1999-01-01

    An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

  19. Methylation of Hg downstream from the Bonanza Hg mine, Oregon

    Science.gov (United States)

    Gray, John E.; Hines, Mark E.; Krabbenhoft, David P.; Thoms, Bryn

    2012-01-01

    Speciation of Hg and conversion to methyl-Hg were evaluated in stream sediment, stream water, and aquatic snails collected downstream from the Bonanza Hg mine, Oregon. Total production from the Bonanza mine was >1360t of Hg, during mining from the late 1800s to 1960, ranking it as an intermediate sized Hg mine on an international scale. The primary objective of this study was to evaluate the distribution, transport, and methylation of Hg downstream from a Hg mine in a coastal temperate climatic zone. Data shown here for methyl-Hg, a neurotoxin hazardous to humans, are the first reported for sediment and water from this area. Stream sediment collected from Foster Creek flowing downstream from the Bonanza mine contained elevated Hg concentrations that ranged from 590 to 71,000ng/g, all of which (except the most distal sample) exceeded the probable effect concentration (PEC) of 1060ng/g, the Hg concentration above which harmful effects are likely to be observed in sediment-dwelling organisms. Concentrations of methyl-Hg in stream sediment collected from Foster Creek varied from 11 to 62ng/g and were highly elevated compared to regional baseline concentrations (0.11-0.82ng/g) established in this study. Methyl-Hg concentrations in stream sediment collected in this study showed a significant correlation with total organic C (TOC, R2=0.62), generally indicating increased methyl-Hg formation with increasing TOC in sediment. Isotopic-tracer methods indicated that several samples of Foster Creek sediment exhibited high rates of Hg-methylation. Concentrations of Hg in water collected downstream from the mine varied from 17 to 270ng/L and were also elevated compared to baselines, but all were below the 770ng/L Hg standard recommended by the USEPA to protect against chronic effects to aquatic wildlife. Concentrations of methyl-Hg in the water collected from Foster Creek ranged from 0.17 to 1.8ng/L, which were elevated compared to regional baseline sites upstream and downstream

  20. A Calibrated Method of Massage Therapy Decreases Systolic Blood Pressure Concomitant With Changes in Heart Rate Variability in Male Rats.

    Science.gov (United States)

    Spurgin, Kurt A; Kaprelian, Anthony; Gutierrez, Roberto; Jha, Vidyasagar; Wilson, Christopher G; Dobyns, Abigail; Xu, Karen H; Curras-Collazo, Margarita C

    2017-02-01

    The purpose of this study was to develop a method for applying calibrated manual massage pressures by using commonly available, inexpensive sphygmomanometer parts and validate the use of this approach as a quantitative method of applying massage therapy to rodents. Massage pressures were monitored by using a modified neonatal blood pressure (BP) cuff attached to an aneroid gauge. Lightly anesthetized rats were stroked on the ventral abdomen for 5 minutes at pressures of 20 mm Hg and 40 mm Hg. Blood pressure was monitored noninvasively for 20 minutes following massage therapy at 5-minute intervals. Interexaminer reliability was assessed by applying 20 mm Hg and 40 mm Hg pressures to a digital scale in the presence or absence of the pressure gauge. With the use of this method, we observed good interexaminer reliability, with intraclass coefficients of 0.989 versus 0.624 in blinded controls. In Long-Evans rats, systolic BP dropped by an average of 9.86% ± 0.27% following application of 40 mm Hg massage pressure. Similar effects were seen following 20 mm Hg pressure (6.52% ± 1.7%), although latency to effect was greater than at 40 mm Hg. Sprague-Dawley rats behaved similarly to Long-Evans rats. Low-frequency/high-frequency ratio, a widely-used index of autonomic tone in cardiovascular regulation, showed a significant increase within 5 minutes after 40 mm Hg massage pressure was applied. The calibrated massage method was shown to be a reproducible method for applying massage pressures in rodents and lowering BP. Copyright © 2016. Published by Elsevier Inc.

  1. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  2. Low-pressure sequential compression of lower limbs enhances forearm skin blood flow.

    Science.gov (United States)

    Amah, Guy; Voicu, Sebastian; Bonnin, Philippe; Kubis, Nathalie

    2016-12-01

    We investigated whether forearm skin blood flow could be improved when a multilayer pulsatile inflatable suit was applied at a low pressure to the lower limbs and abdomen. We hypothesized that a non-invasive purely mechanical stimulation of the lower limbs could induce remote forearm blood flow modifications. The pulsatile suit induced a sequential compartmentalized low compression (65 mmHg), which was synchronized with each diastole of the cardiac cycle with each phase evolving centripetally (lower limbs to abdomen). Modifications of the forearm skin blood flow were continuously recorded by laser Doppler flowmetry (LDF) at baseline and during the pulsatile suit application. Endothelium-dependent and endothelium-independent vasodilations of the forearm skin microcirculation were measured by LDF in response to a local transdermal iontophoretic application of acetylcholine (ACh-test) and to hyperthermia (hyperT- test). Twenty-four healthy volunteers, 12 men and 12 women (43±14 years) were included in the study. LDF responses increased 1) under pulsatile suit (97±106%, p.

  3. Blood pressure changes in dogs with babesiosis

    Directory of Open Access Journals (Sweden)

    L.S. Jacobson

    2000-07-01

    Full Text Available Systemic arterial blood pressures were measured in 30 dogs with acute babesiosis, 10 each with mild uncomplicated, severe uncomplicated and complicated disease. Ten healthy dogs were used as controls. Hypotension was defined as more than 3 standard deviations below the control mean. Normal mean pressures (±SD were: systolic arterial pressure 151 (±11 mm Hg, diastolic arterial pressure 89 (±8 mm Hg and mean arterial pressure 107 (±10 mmHg. Hypotension was the most frequent abnormality, and increased strikingly in incidence as disease severity increased, with 5/10 dogs in the complicated group being hypotensive for systolic, diastolic and mean arterial pressures, compared with 2/10 in the severe uncomplicated group and 0/10 in the mild uncomplicated group. Systolic, diastolic and mean arterial pressures in the complicated group and severe uncomplicated group, and systolic pressure in the mild uncomplicated group, were significantly lower than in the controls. There were no significant relationships between arterial pressures and age, pulse rate, respiratory rate, temperature, mucous membrane colour or haematocrit. There was a significant negative correlation between arterial pressures and white cell and immature neutrophil counts. Arterial pressures differed significantly between dogs that were clinically collapsed and those that were not, but not between survivors and non-survivors. Pulse pressure (systolic - diastolic was low in 7/10 complicated, 1/10 mild uncomplicated, and 1/10 severe uncomplicated cases, and differed significantly between the complicated and control groups. The high incidence of hypotension in clinically severe babesiosis has important implications for therapy.

  4. Design of passive coolers for light-emitting diode lamps using topology optimisation

    DEFF Research Database (Denmark)

    Alexandersen, Joe; Sigmund, Ole; Meyer, Knud Erik

    2018-01-01

    Topology optimised designs for passive cooling of light-emitting diode (LED) lamps are investigated through extensive numerical parameter studies. The designs are optimised for either horizontal or vertical orientations and are compared to a lattice-fin design as well as a simple parameter......, while maintaining low sensitivity to orientation. Furthermore, they exhibit several defining features and provide insight and general guidelines for the design of passive coolers for LED lamps....

  5. A PILOT STUDY ON THE EFFECTS OF MAGNESIUM SUPPLEMENTATION WITH HIGH AND LOW HABITUAL DIETARY MAGNESIUM INTAKE ON RESTING AND RECOVERY FROM AEROBIC AND RESISTANCE EXERCISE AND SYSTOLIC BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    Lindsy S. Kass

    2013-03-01

    Full Text Available The effects of magnesium supplementation on blood pressure (BP have been studied for over 25 years and results have been inconsistent. Blood pressure reductions in randomized studies have varied from 12 mmHg reductions to no reduction. The objective of this pilot intervention was to investigate the effect of magnesium supplementation on systolic blood pressure whilst resting and during recovery from aerobic and resistance exercise and on performance. A further objective was to see whether the effect of a high vs low habitual dietary magnesium intake affected these results. Sixteen male volunteers were randomly assigned to either a 300 mg·d-1 magnesium oxide supplementation (MO or a control group (CG for 14 days. Resting blood pressure (BP and heart rate (HR were measured before subjects performed a maximal 30 minute cycle, immediately followed by three x 5 second isometric bench press, both at baseline and after the intervention. Blood pressure and heart rate were recorded immediately post exercise and after five minutes recovery. A 3 day food diary was recorded for all subjects to measure dietary magnesium intake. At the end of the intervention, the supplemented group, had a reduction in mean resting systolic BP by 8.9 mmHg (115.125 ± 9.46 mmHg, p = 0.01 and post exercise by 13 mmHg (122.625 ± 9. 88 mmHg, p = 0.01. Recovery BP was 11.9 mmHg lower in the intervention group compared to control (p = 0.006 and HR decreased by 7 beats per minute in the experimental group (69.0 ± 11.6 bpm, p = 0. 02. Performance indicators did not change within and between the groups. Habitual dietary magnesium intake affected both resting and post exercise systolic BP and the subsequent effect of the magnesium supplementation. These results have an implication in a health setting and for health and exercise but not performance.

  6. Three Toxic Heavy Metals in Open-Angle Glaucoma with Low-Teen and High-Teen Intraocular Pressure: A Cross-Sectional Study from South Korea.

    Directory of Open Access Journals (Sweden)

    Si Hyung Lee

    Full Text Available To investigate the association between heavy metal levels and open-angle glaucoma (OAG with low- and high-teen baseline intraocular pressure (IOP using a population-based study design.This cross-sectional study included 5,198 participants older than 19 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES from 2008 to 2012 and had blood heavy metal levels available. The OAG with normal baseline IOP (IOP ≤ 21 mmHg subjects were stratified into low-teen OAG (baseline IOP ≤ 15 mmHg and high-teen OAG (15 mmHg < baseline IOP ≤ 21 mmHg, and the association between blood lead, mercury, and cadmium levels and glaucoma prevalence was assessed for low- and high-teen OAG.The adjusted geometric mean of blood cadmium levels was significantly higher in subjects with low-teen OAG than that of the non-glaucomatous group (P = 0.028, whereas there were no significant differences in blood lead and mercury levels. After adjusting for potential confounders, the low-teen OAG was positively associated with log-transformed blood cadmium levels (OR, 1.41; 95% confidence interval (CI, 1.03-1.93; P = 0.026. For high-teen OAG, log-transformed blood levels of the three heavy metals were not associated with disease prevalence. The association between log-transformed blood cadmium levels and low-teen OAG was significant only in men (OR, 1.65; 95% CI, 1.10-2.48; P = 0.016, and not in women (OR, 1.10; 95% CI, 0.66-1.85; P = 0.709.The results of this study suggest that cadmium toxicity could play a role in glaucoma pathogenesis, particularly in men and in OAG with low-teen baseline IOP.

  7. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  8. Can Ambulatory Blood Pressure Variability Contribute to Individual Cardiovascular Risk Stratification?

    Directory of Open Access Journals (Sweden)

    Annamária Magdás

    2016-01-01

    Full Text Available Objective. The aim of this study is to define the normal range for average real variability (ARV and to establish whether it can be considered as an additional cardiovascular risk factor. Methods. In this observational study, 110 treated hypertensive patients were included and admitted for antihypertensive treatment adjustment. Circadian blood pressure was recorded with validated devices. Blood pressure variability (BPV was assessed according to the ARV definition. Based on their variability, patients were classified into low, medium, and high variability groups using the fuzzy c-means algorithm. To assess cardiovascular risk, blood samples were collected. Characteristics of the groups were compared by ANOVA tests. Results. Low variability was defined as ARV below 9.8 mmHg (32 patients, medium as 9.8–12.8 mmHg (48 patients, and high variability above 12.8 mmHg (30 patients. Mean systolic blood pressure was 131.2 ± 16.7, 135.0 ± 12.1, and 141.5 ± 11.4 mmHg in the low, medium, and high variability groups, respectively (p=0.0113. Glomerular filtration rate was 78.6 ± 29.3, 74.8 ± 26.4, and 62.7±23.2 mL/min/1.73 m2 in the low, medium, and high variability groups, respectively (p=0.0261. Conclusion. Increased values of average real variability represent an additional cardiovascular risk factor. Therefore, reducing BP variability might be as important as achieving optimal BP levels, but there is need for further studies to define a widely acceptable threshold value.

  9. Spectroscopic investigation of indium halides as substitudes of mercury in low pressure discharges for lighting applications

    Energy Technology Data Exchange (ETDEWEB)

    Briefi, Stefan

    2012-05-22

    Low pressure discharges with indium halides as radiator are discussed as substitutes for hazardous mercury in conventional fluorescent lamps. In this work, the applicability of InBr and InCl in a low pressure discharge light source is investigated. The aim is to identify and understand the physical processes which determine the discharge characteristics and the efficiency of the generated near-UV emission of the indium halide molecule and of the indium atom which is created due to dissociation processes in the plasma. As discharge vessels sealed cylindrical quartz glass tubes which contain a defined amount of indium halide and a rare gas are used. Preliminary investigations showed that for a controlled variation of the indium halide density a well-defined cold spot setup is mandatory. This was realized in the utilized experimental setup. The use of metal halides raises the issue, that power coupling by internal electrodes is not possible as the electrodes would quickly be eroded by the halides. The comparison of inductive and capacitive RF-coupling with external electrodes revealed that inductively coupled discharges provide higher light output and much better long term stability. Therefore, all investigations are carried out using inductive RF-coupling. The diagnostic methods optical emission and white light absorption spectroscopy are applied. As the effects of absorption-signal saturation and reabsorption of emitted radiation within the plasma volume could lead to an underestimation of the determined population densities by orders of magnitude, these effects are considered in the data evaluation. In order to determine the electron temperature and the electron density from spectroscopic measurements, an extended corona model as population model of the indium atom has been set up. A simulation of the molecular emission spectra has been implemented to investigate the rovibrational population processes of the indium halide molecules. The impact of the cold spot

  10. 196Hg and 202Hg isotopic ratios in chondrites: revisited

    International Nuclear Information System (INIS)

    Jovanovic, S.; Reed, G.W. Jr.

    1976-01-01

    Additional evidence for an isotopically anomalous Hg fraction in unequilibrated meteorites has been obtained using neutron activation to produce 196 Hg and 202 Hg followed by stepwise heating to extract the Hg. In the latest experiments Allende matrix samples released the anomalous Hg but various high-temperature inclusions did not. Nucleogenetic processes are suggested as the probable cause of the anomaly. (Auth.)

  11. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  12. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  13. Phonons and their dispersion in model ferroelastics Hg2Hal2

    Science.gov (United States)

    Roginskii, E. M.; Kvasov, A. A.; Markov, Yu. F.; Smirnov, M. B.

    2012-05-01

    Dispersion relations of the acoustic and optical phonon frequencies have been calculated and plotted, and the density of states of the phonon spectrum of Hg2Cl2 and Hg2Br2 crystals has been derived. The effect of hydrostatic pressure on the frequencies of acoustic and optical phonons and their dispersion has been theoretically analyzed. It has been found that an increase in the pressure leads to a strong softening of the slowest acoustic TA branch (the soft mode) at the X point of the Brillouin zone boundary, which is consistent with the phenomenological Landau theory and correlates with experiment.

  14. Performance of room temperature mercuric iodide (HgI2) detectors in the ultra low energy x-ray region

    International Nuclear Information System (INIS)

    Dabrowski, A.J.; Iwanczyk, J.S.; Barton, J.B.; Huth, G.C.; Whited, R.; Ortale, C.; Economou, T.E.; Turkevich, A.L.

    1980-01-01

    Performance of room temperature mercuric iodide x-ray spectrometers has been recently improved through new fabrication techniques and further development of low noise associated electronic systems. This progress has extended the range of measurements to the ultra low energy x-ray region at room temperature. This paper reports the study of the effect of contact material on the performance of HgI 2 detectors in the low energy x-ray region

  15. Direct-current converter for gas-discharge lamps

    Science.gov (United States)

    Lutus, P.

    1980-01-01

    Metal/halide and similar gas-discharge lamps are powered from low-voltage dc source using small efficient converter. Converter is useful whenever 60-cycle ac power is not available or where space and weight allocations are limited. Possible applications are offshore platforms, mobile homes, and emergency lighting. Design innovations give supply high reliability and efficiency up to 75 percent.

  16. Geometric Modelling of Octagonal Lamp Poles

    Science.gov (United States)

    Chan, T. O.; Lichti, D. D.

    2014-06-01

    Lamp poles are one of the most abundant highway and community components in modern cities. Their supporting parts are primarily tapered octagonal cones specifically designed for wind resistance. The geometry and the positions of the lamp poles are important information for various applications. For example, they are important to monitoring deformation of aged lamp poles, maintaining an efficient highway GIS system, and also facilitating possible feature-based calibration of mobile LiDAR systems. In this paper, we present a novel geometric model for octagonal lamp poles. The model consists of seven parameters in which a rotation about the z-axis is included, and points are constrained by the trigonometric property of 2D octagons after applying the rotations. For the geometric fitting of the lamp pole point cloud captured by a terrestrial LiDAR, accurate initial parameter values are essential. They can be estimated by first fitting the points to a circular cone model and this is followed by some basic point cloud processing techniques. The model was verified by fitting both simulated and real data. The real data includes several lamp pole point clouds captured by: (1) Faro Focus 3D and (2) Velodyne HDL-32E. The fitting results using the proposed model are promising, and up to 2.9 mm improvement in fitting accuracy was realized for the real lamp pole point clouds compared to using the conventional circular cone model. The overall result suggests that the proposed model is appropriate and rigorous.

  17. Kinetics and mechanism of jack bean urease inhibition by Hg2+

    Directory of Open Access Journals (Sweden)

    Du Nana

    2012-12-01

    Full Text Available Abstract Background Jack bean urease (EC 3.5.1.5 is a metalloenzyme, which catalyzes the hydrolysis of urea to produce ammonia and carbon dioxide. The heavy metal ions are common inhibitors to control the rate of the enzymatic urea hydrolysis, which take the Hg2+ as the representative. Hg2+ affects the enzyme activity causing loss of the biological function of the enzyme, which threatens the survival of many microorganism and plants. However, inhibitory kinetics of urease by the low concentration Hg2+ has not been explored fully. In this study, the inhibitory effect of the low concentration Hg2+ on jack bean urease was investigated in order to elucidate the mechanism of Hg2+ inhibition. Results According to the kinetic parameters for the enzyme obtained from Lineweaver–Burk plot, it is shown that the Km is equal to 4.6±0.3 mM and Vm is equal to 29.8±1.7 μmol NH3/min mg. The results show that the inhibition of jack bean urease by Hg2+ at low concentration is a reversible reaction. Equilibrium constants have been determined for Hg2+ binding with the enzyme or the enzyme-substrate complexes (Ki =0.012 μM. The results show that the Hg2+ is a noncompetitive inhibitor. In addition, the kinetics of enzyme inhibition by the low concentration Hg2+ has been studied using the kinetic method of the substrate reaction. The results suggest that the enzyme first reversibly and quickly binds Hg2+ and then undergoes a slow reversible course to inactivation. Furthermore, the rate constant of the forward reactions (k+0 is much larger than the rate constant of the reverse reactions (k-0. By combining with the fact that the enzyme activity is almost completely lost at high concentration, the enzyme is completely inactivated when the Hg2+ concentration is high enough. Conclusions These results suggest that Hg2+ has great impacts on the urease activity and the established inhibition kinetics model is suitable.

  18. 30 CFR 75.1703 - Portable electric lamps.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...

  19. Impact of Physical Activity Interventions on Blood Pressure in Brazilian Populations

    Directory of Open Access Journals (Sweden)

    Vivian Freitas Rezende Bento

    2015-01-01

    Full Text Available Background: High blood pressure is associated with cardiovascular disease, which is the leading cause of mortality in the Brazilian population. Lifestyle changes, including physical activity, are important for lowering blood pressure levels and decreasing the costs associated with outcomes. Objective: Assess the impact of physical activity interventions on blood pressure in Brazilian individuals. Methods: Meta-analysis and systematic review of studies published until May 2014, retrieved from several health sciences databases. Seven studies with 493 participants were included. The analysis included parallel studies of physical activity interventions in adult populations in Brazil with a description of blood pressure (mmHg before and after the intervention in the control and intervention groups. Results: Of 390 retrieved studies, eight matched the proposed inclusion criteria for the systematic review and seven randomized clinical trials were included in the meta-analysis. Physical activity interventions included aerobic and resistance exercises. There was a reduction of -10.09 (95% CI: -18.76 to -1.43 mmHg in the systolic and -7.47 (95% CI: -11.30 to -3.63 mmHg in the diastolic blood pressure. Conclusions: Available evidence on the effects of physical activity on blood pressure in the Brazilian population shows a homogeneous and significant effect at both systolic and diastolic blood pressures. However, the strength of the included studies was low and the methodological quality was also low and/or regular. Larger studies with more rigorous methodology are necessary to build robust evidence.

  20. Laparoscopic Cholecystectomy Under Spinal Anesthesia with Low-Pressure Pneumoperitoneum - Prospective Study of 150 Cases

    Directory of Open Access Journals (Sweden)

    Sunder Goyal

    2012-08-01

    Materials and Methods: In a private rural medical college, 150 patients were selected prospectively for laparoscopic cholecystectomy, under low-pressure (8mmHg pneumoperitoneum and under spinal anesthesia over a span of one and a half years. Injection bupivacaine (0.5% was used for spinal anesthesia. All ports were made in a head-down position to avoid hypotension. Shoulder pain was managed by reassurance as well as by diverting the attention and sedation in a few cases. Results: We successfully performed the operations in 145 patients without major complications. Spinal anesthesia was converted to general anesthesia in five patients due to severe shoulder pain. Age varied between 21 and 75 years. Duration of operation time (skin to skin was between 40 and 80 minutes. Twenty-nine patients complained of right shoulder pain. Most of them were managed by reassurance from the anesthetist and a few needed an injection of fentanyl along with midazolam. Conclusion: Laparoscopic cholecystectomy with low-pressure CO2 pneumoperitoneum is feasible and safe under spinal anesthesia. Incidence of postoperative shoulder pain and complications are comparable with laparoscopic cholecystectomy under general anesthesia. [Arch Clin Exp Surg 2012; 1(4.000: 224-228

  1. A thermodynamic stability of bulk and epitaxial CdHgTe, ZnHgTe and MnHgTe solid solutions

    International Nuclear Information System (INIS)

    Dejbuk, V.G.; Dremlyuzhenko, S.G.; Ostapov, S.Eh.

    2005-01-01

    A thermodynamics of Cd 1-x Hg x Te, Zn x Hg 1-x Te and Mg x Hg 1-x Te alloys has been investigated for a delta-lattice parameter model. The phase diagrams obtained show the stability of Cd 1-x Hg x Te, Zn x Hg 1-x Te in the whole range of compositions, alongside with a miscibility gap for Mn x Hg 1-x Te being of 0.35 x Hg 1-x Te/CdTe and Mn x Hg 1-x Te/Cd 0.96 Zn 0.04 Te epitaxial films result in lowering critical temperatures and narrowing the miscibility gap [ru

  2. Fluorescent discharge lamp

    Science.gov (United States)

    Mukai, E.; Otsuka, H.; Nomi, K.; Honmo, I.

    1982-01-01

    A rapidly illuminating fluorescent lamp 1,200 mm long and 32.5 mm in diameter with an interior conducting strip which is compatible with conventional fixtures and ballasts is described. The fluorescent lamp is composed of a linear glass tube, electrodes sealed at both ends, mercury and raregas sealed in the glass tube, a fluorescent substance clad on the inner walls of the glass tube, and a clad conducting strip extending the entire length of the glass tube in the axial direction on the inner surface of the tube.

  3. Comparison of ultraviolet light-emitting diodes and low-pressure mercury-arc lamps for disinfection of water.

    Science.gov (United States)

    Sholtes, Kari A; Lowe, Kincaid; Walters, Glenn W; Sobsey, Mark D; Linden, Karl G; Casanova, Lisa M

    2016-09-01

    Ultraviolet (UV) light-emitting diodes (LEDs) emitting at 260 nm were evaluated to determine the inactivation kinetics of bacteria, viruses, and spores compared to low-pressure (LP) UV irradiation. Test microbes were Escherichia coli B, a non-enveloped virus (MS-2), and a bacterial spore (Bacillus atrophaeus). For LP UV, 4-log10 reduction doses were: E. coli B, 6.5 mJ/cm(2); MS-2, 59.3 mJ/cm(2); and B. atrophaeus, 30.0 mJ/cm(2). For UV LEDs, the 4-log10 reduction doses were E. coli B, 6.2 mJ/cm(2); MS-2, 58 mJ/cm(2); and B. atrophaeus, 18.7 mJ/cm(2). Microbial inactivation kinetics of the two UV technologies were not significantly different for E. coli B and MS-2, but were different for B. atrophaeus spores. UV LEDs at 260 nm are at least as effective for inactivating microbes in water as conventional LP UV sources and should undergo further development in treatment systems to disinfect drinking water.

  4. Collisional and radiative processes in fluorescent lamps

    International Nuclear Information System (INIS)

    Lister, Graeme G.

    2003-01-01

    Since electrode life is the major limiting factor in operating fluorescent lamps, many lighting companies have introduced 'electrodeless' fluorescent lamps, using inductively coupled discharges. These lamps often operate at much higher power loadings than standard lamps and numerical models have not been successful in reproducing experimental measurements in the parameter ranges of interest. A comprehensive research program was undertaken to study the fundamental physical processes of these discharges, co-funded by the Electric Power Research Institute (EPRI) and OSRAM SYLVANIA under the name of ALITE. The program included experiments and modeling of radiation transport, computations of electron-atom and atom-atom cross sections and the first comprehensive power balance studies of a highly loaded fluorescent lamp. Results from the program and their importance to the understanding of the physics of fluorescent lamps are discussed, with particular emphasis on the important collisional and radiative processes. Comparisons between results of experimental measurements and numerical models are presented

  5. Phase out of incandescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Since early 2007 almost all OECD and many non-OECD governments have announced policies aimed at phasing-out incandescent lighting within their jurisdictions. This study considers the implications of these policy developments in terms of demand for regulatory compliant lamps and the capacity and motivation of the lamp industry to produce efficient lighting products in sufficient volume to meet future demand. To assess these issues, it reviews the historic international screw-based lamp market, describes the status of international phase-out policies and presents projections of anticipated market responses to regulatory requirements to determine future demand for CFLs.

  6. Zuotai and HgS differ from HgCl2 and methyl mercury in Hg accumulation and toxicity in weanling and aged rats.

    Science.gov (United States)

    Zhang, Bin-Bin; Li, Wen-Kai; Hou, Wei-Yu; Luo, Ya; Shi, Jing-Zhen; Li, Cen; Wei, Li-Xin; Liu, Jie

    2017-09-15

    Mercury sulfides are used in Ayurvedic medicines, Tibetan medicines, and Chinese medicines for thousands of years and are still used today. Cinnabar (α-HgS) and metacinnabar (β-HgS) are different from mercury chloride (HgCl 2 ) and methylmercury (MeHg) in their disposition and toxicity. Whether such scenario applies to weanling and aged animals is not known. To address this question, weanling (21d) and aged (450d) rats were orally given Zuotai (54% β-HgS, 30mg/kg), HgS (α-HgS, 30mg/kg), HgCl 2 (34.6mg/kg), or MeHg (MeHgCl, 3.2mg/kg) for 7days. Accumulation of Hg in kidney and liver, and the toxicity-sensitive gene expressions were examined. Animal body weight gain was decreased by HgCl 2 and to a lesser extent by MeHg, but unaltered after Zuotai and HgS. HgCl 2 and MeHg produced dramatic tissue Hg accumulation, increased kidney (kim-1 and Ngal) and liver (Ho-1) injury-sensitive gene expressions, but such changes are absent or mild after Zuotai and HgS. Aged rats were more susceptible than weanling rats to Hg toxicity. To examine roles of transporters in Hg accumulation, transporter gene expressions were examined. The expression of renal uptake transporters Oat1, Oct2, and Oatp4c1 and hepatic Oatp2 was decreased, while the expression of renal efflux transporter Mrp2, Mrp4 and Mdr1b was increased following HgCl 2 and MeHg, but unaffected by Zuotai and HgS. Thus, Zuotai and HgS differ from HgCl 2 and MeHg in producing tissue Hg accumulation and toxicity, and aged rats are more susceptible than weanling rats. Transporter expression could be adaptive means to reduce tissue Hg burden. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. 30 CFR 57.12035 - Weatherproof lamp sockets.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 57.12035 Section 57.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type...

  8. 30 CFR 56.12035 - Weatherproof lamp sockets.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Weatherproof lamp sockets. 56.12035 Section 56.12035 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12035 Weatherproof lamp sockets. Lamp sockets shall be of a weatherproof type where they are exposed to...

  9. Low-temperature photoluminescence of detector-grade HgI2

    International Nuclear Information System (INIS)

    Merz, J.L.; Wu, Z.L.; van den Berg, L.; Schnepple, W.F.

    1981-01-01

    The low-temperature photoluminescence of HgI 2 is reported. Three main luminescence bands are observed, with peaks at approx. 2.30, 2.20, and 2.00 eV at 77 K. At 4.2 K, the highest energy peak shows considerable structure. The temperature dependence of these lines indicates both free and bound exciton recombination, and very small exciton binding energies (approx. 3 to 5 MeV) have been estimated. A comparison of the results of sublimation and doping experiments suggests that the lowest energy band may be related to impurities, whereas the middle-energy band is related to I content. The two strongest bound exciton lines comprising the high-energy band show systematic correlations with the middle-energy, I-related band. Further correlations between these spectral features and the performance of nuclear radiation detectors fabricated from these samples are also noted. The temperature coefficient of the band gap is estimated from the spectral shift of luminescence lines to be approximately -1.13 x 10 -4 eV/K between 32 K and 45 K

  10. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.

    Science.gov (United States)

    Chopra, Sascha Santosh; Wolf, Stefan; Rohde, Veit; Freimann, Florian Baptist

    2015-01-01

    Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, comprising telemetric piezoresistive probes at two different sites (epigastric and pelvic) for direct pressure measurement and intragastric and intravesical probes for indirect measurement. Results. The mean difference between the invasive IAP measurements using telemetric pressure probes and the IVP measurements was -0.58 mmHg. The bias between the invasive IAP measurements and the IGP measurements was 3.8 mmHg. Compared to the realistic results of the intraperitoneal and intravesical measurements, the intragastric data showed a strong tendency towards decreased values. The hydrostatic character of the IAP was eliminated at high-pressure levels. Conclusion. We conclude that intragastric pressure measurement is potentially hazardous and might lead to inaccurately low intra-abdominal pressure values. This may result in missed diagnosis of elevated abdominal pressure or even ACS. The intravesical measurements showed the most accurate values during baseline pressure and both high-pressure plateaus.

  11. Lamp with a truncated reflector cup

    Science.gov (United States)

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  12. The Effect of Endotracheal Inflation Technique on Endotracheal Cuff Pressure

    Science.gov (United States)

    1999-10-01

    had upon tracheal wall blood flow of anesthetized dogs . This study found that low-volume, high-pressure cuffs required 320 to 360 mm Hg of pressure to...Som, P., Khilnani, M., Keller, R., & Som, M. (1972). Tracheal stenosis secondary to cuffed tubes. Mount Siai Journal of Medicine, 40, 652-665

  13. 47 CFR 17.54 - Rated lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... voltage. To insure the necessary lumen output by obstruction lights, the rated voltage of incandescent lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  14. Energy and Emission Characteristics of a Short-Arc Xenon Flash Lamp Under "Saturated" Optical Brightness Conditions

    Science.gov (United States)

    Kamrukov, A. S.; Kireev, S. G.; Kozlov, N. P.; Shashkovskii, S. G.

    2017-09-01

    We present the results of a study of the electrical, energy, and spectral brightness characteristics of an experimental three-electrode high-pressure xenon flash lamp under conditions ensuring close to maximum possible spectral brightness for the xenon emission. We show that under saturated optical brightness conditions (brightness temperature in the visible region of the spectrum 30,000 K), emission of a pulsed discharge in xenon is quite different from the emission from an ideal blackbody: the maximum brightness temperatures are 24,000 K in the short-wavelength UV region and 19,000 K in the near IR range. The relative fraction of UV radiation in the emission spectrum of the lamp is >50%, which lets us consider such lamps as promising broadband sources of radiation with high spectral brightness for many important practical applications.

  15. Determination of Hg{sup 2+} by on-line separation and pre-concentration with atmospheric-pressure solution-cathode glow discharge atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qing [Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 200050 (China); Zhang, Zhen [Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 200050 (China); School of Materials Science and Engineering, Shanghai University, Shanghai 200072 (China); Wang, Zheng, E-mail: wangzheng@mail.sic.ac.cn [Shanghai Institute of Ceramics, Chinese Academy of Science, Shanghai 200050 (China)

    2014-10-03

    Highlights: • A modified SBA-15 mesoporous silica (SH-SBA-15) was synthesized as a sorbent. • On-line SPE combined with SCGD-AES based on FIA was used to detect Hg{sup 2+} firstly. • A simple, low-cost Hg{sup 2+} analysis in a complex matrix was established. • The sensitive detection of Hg{sup 2+} was achieved with a detection limit of 0.75 μg L{sup −1}. - Abstract: A simple and sensitive method to determine Hg{sup 2+} was developed by combining solution-cathode glow discharge atomic emission spectrometry (SCGD-AES) with flow injection (FI) based on on-line solid-phase extraction (SPE). We synthesized L-cysteine-modified mesoporous silica and packed it in an SPE microcolumn, which was experimentally determined to possess a good mercury adsorption capacity. An enrichment factor of 42 was achieved under optimized Hg{sup 2+} elution conditions, namely, an FI flow rate of 2.0 mL min{sup −1} and an eluent comprised of 10% thiourea in 0.2 mol L{sup −1} HNO{sub 3}. The detection limit of FI–SCGD-AES was determined to be 0.75 μg L{sup −1}, and the precision of the 11 replicate Hg{sup 2+} measurements was 0.86% at a concentration of 100 μg L{sup −1}. The proposed method was validated by determining Hg{sup 2+} in certified reference materials such as human hair (GBW09101b) and stream sediment (GBW07310)

  16. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  17. Models of brachial to finger pulse wave distortion and pressure decrement.

    Science.gov (United States)

    Gizdulich, P; Prentza, A; Wesseling, K H

    1997-03-01

    To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

  18. Factors associated with blood oxygen partial pressure and carbon dioxide partial pressure regulation during respiratory extracorporeal membrane oxygenation support: data from a swine model.

    Science.gov (United States)

    Park, Marcelo; Mendes, Pedro Vitale; Costa, Eduardo Leite Vieira; Barbosa, Edzangela Vasconcelos Santos; Hirota, Adriana Sayuri; Azevedo, Luciano Cesar Pontes

    2016-01-01

    The aim of this study was to explore the factors associated with blood oxygen partial pressure and carbon dioxide partial pressure. The factors associated with oxygen - and carbon dioxide regulation were investigated in an apneic pig model under veno-venous extracorporeal membrane oxygenation support. A predefined sequence of blood and sweep flows was tested. Oxygenation was mainly associated with extracorporeal membrane oxygenation blood flow (beta coefficient = 0.036mmHg/mL/min), cardiac output (beta coefficient = -11.970mmHg/L/min) and pulmonary shunting (beta coefficient = -0.232mmHg/%). Furthermore, the initial oxygen partial pressure and carbon dioxide partial pressure measurements were also associated with oxygenation, with beta coefficients of 0.160 and 0.442mmHg/mmHg, respectively. Carbon dioxide partial pressure was associated with cardiac output (beta coefficient = 3.578mmHg/L/min), sweep gas flow (beta coefficient = -2.635mmHg/L/min), temperature (beta coefficient = 4.514mmHg/ºC), initial pH (beta coefficient = -66.065mmHg/0.01 unit) and hemoglobin (beta coefficient = 6.635mmHg/g/dL). In conclusion, elevations in blood and sweep gas flows in an apneic veno-venous extracorporeal membrane oxygenation model resulted in an increase in oxygen partial pressure and a reduction in carbon dioxide partial pressure 2, respectively. Furthermore, without the possibility of causal inference, oxygen partial pressure was negatively associated with pulmonary shunting and cardiac output, and carbon dioxide partial pressure was positively associated with cardiac output, core temperature and initial hemoglobin.

  19. INTRAOCULAR PRESSURE AND EXAMINATION FINDINGS IN THREE SPECIES OF CENTRAL AND SOUTH AMERICAN TREE FROGS (CRUZIOHYLA CRASPEDOPUS, CRUZIOHYLA CALCARIFER, AND ANOTHECA SPINOSA).

    Science.gov (United States)

    Lewin, Andrew C; Hausmann, Jennifer C; Miller, Paul E

    2017-09-01

    The purpose of this prospective study was to describe intraocular pressure (IOP) and examination findings in three tree frog species (Cruziohyla craspedopus [fringe leaf frog], Cruziohyla calcarifer [splendid leaf frog], and Anotheca spinosa [spiny-headed or coronated tree frog]). Thirty-one C. craspedopus, four C. calcarifer, and five A. spinosa were weighed, sexed based on phenotype where possible, and examined using slit-lamp biomicroscopy and indirect ophthalmoscopy. IOP was measured using the TonoVet and TonoLab rebound tonometers while the frogs were held two ways (unrestrained, then restrained). Statistical differences were determined using one-way analysis of variance (ANOVA) and t-tests. Mean ± SD IOP (TonoVet and TonoLab, respectively) was 15.1 ± 2.5 mmHg and 15.6 ± 4.1 mmHg in C. craspedopus; 14.8 ± 1.5 mmHg and 18.8 ± 3.1 mmHg in C. calcarifer; and 9.1 ± 2.1 mmHg and 10.8 ± 1.4 mmHg in A. spinosa. There was no significant difference in IOP in C. craspedopus by eye (Right vs Left), tonometer, or restraint method. IOP in female C. craspedopus was 1-3 mm Hg higher than in males with both devices (P Cruziohyla genus frogs and A. spinosa for the TonoVet (P < 0.05). There was no difference in IOP measurements between the TonoVet and TonoLab in C. craspedopus. IOP varied by gender in C. craspedopus and between species, but not by tonometer. Ocular abnormalities were minimal in this group of captive bred frogs.

  20. 199Hg Moessbauer measurements on mercury, alloys and Hg-fluorides

    International Nuclear Information System (INIS)

    Wurtinger, W.; Kankeleit, E.

    1979-01-01

    The Moessbauer effect on the 158 keV 5/2 - -1/2 - transition in 199 Hg, of the order of 10 ppm, has been studied using the current integration technique. The isomer shift between the Hg(I)- and Hg(II)-fluorides as well as the quadrupole splitting in Hg 2 Pt and Hg 2 F 2 are interpreted in terms of relativistic Hartree-Fock-Slater and Molecular Orbital calculations. The following nuclear parameters could be derived: Δ[r 2 ] = (3.2+-1.1) 10 -3 fm 2 and Q(5/2 - ) = (-0.8+-0.4)b. Evidence for an oblate triaxially deformed 199 Hg nucleus is derived from particle plus rotor calculations. (orig.)

  1. Increased blood pressure can reduce fatigue of thenar muscles paralyzed after spinal cord injury

    NARCIS (Netherlands)

    Butler, JE; Ribot-Ciscar, E; Zijdewind, Inge; Thomas, CK

    The aim of this study was to evaluate whether increases in blood pressure, and presumably muscle perfusion pressure, improve the endurance of thenar muscles paralyzed chronically by cervical spinal cord injury (SCI). Resting mean arterial pressure (MAP) was low in all eight subjects (64 +/- 2 mmHg).

  2. HgCdTe e-avalanche photodiode detector arrays

    Directory of Open Access Journals (Sweden)

    Anand Singh

    2015-08-01

    Full Text Available Initial results on the MWIR e-APD detector arrays with 30 μm pitch fabricated on LPE grown compositionally graded p-HgCdTe epilayers are presented. High dynamic resistance times active area (R0A product 2 × 106 Ω-cm2, low dark current density 4 nA/cm2 and high gain 5500 at -8 V were achieved in the n+-υ-p+ HgCdTe e-APD at 80 K. LPE based HgCdTe e-APD development makes this technology amenable for adoption in the foundries established for the conventional HgCdTe photovoltaic detector arrays without any additional investment.

  3. Hydrothermal growth of wheatear-shaped ZnO microstructures and ...

    Indian Academy of Sciences (India)

    2017-09-12

    Sep 12, 2017 ... particles considerably, which led to the final flower-like shape. Herein, a similar ... UV-light irradiation. A 250W high-pressure Hg lamp (λmax = 365 nm) was ... the suspension was placed under UV-light irradiation. A quan-.

  4. Oxidative stress in MeHg-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Marcelo, E-mail: farina@ccb.ufsc.br [Departamento de Bioquimica, Centro de Ciencias Biologicas, Universidade Federal de Santa Catarina, Florianopolis, SC (Brazil); Aschner, Michael [Department of Pediatrics, Vanderbilt University Medical Center, Nashville, TN (United States); Department of Pharmacology, Vanderbilt University Medical Center, Nashville, TN (United States); Rocha, Joao B.T., E-mail: jbtrocha@yahoo.com.br [Departamento de Quimica, Centro de Ciencias Naturais e Exatas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil)

    2011-11-15

    Methylmercury (MeHg) is an environmental toxicant that leads to long-lasting neurological and developmental deficits in animals and humans. Although the molecular mechanisms mediating MeHg-induced neurotoxicity are not completely understood, several lines of evidence indicate that oxidative stress represents a critical event related to the neurotoxic effects elicited by this toxicant. The objective of this review is to summarize and discuss data from experimental and epidemiological studies that have been important in clarifying the molecular events which mediate MeHg-induced oxidative damage and, consequently, toxicity. Although unanswered questions remain, the electrophilic properties of MeHg and its ability to oxidize thiols have been reported to play decisive roles to the oxidative consequences observed after MeHg exposure. However, a close examination of the relationship between low levels of MeHg necessary to induce oxidative stress and the high amounts of sulfhydryl-containing antioxidants in mammalian cells (e.g., glutathione) have led to the hypothesis that nucleophilic groups with extremely high affinities for MeHg (e.g., selenols) might represent primary targets in MeHg-induced oxidative stress. Indeed, the inhibition of antioxidant selenoproteins during MeHg poisoning in experimental animals has corroborated this hypothesis. The levels of different reactive species (superoxide anion, hydrogen peroxide and nitric oxide) have been reported to be increased in MeHg-exposed systems, and the mechanisms concerning these increments seem to involve a complex sequence of cascading molecular events, such as mitochondrial dysfunction, excitotoxicity, intracellular calcium dyshomeostasis and decreased antioxidant capacity. This review also discusses potential therapeutic strategies to counteract MeHg-induced toxicity and oxidative stress, emphasizing the use of organic selenocompounds, which generally present higher affinity for MeHg when compared to the classically

  5. Label-free colorimetric detection of Hg²⁺ based on Hg²⁺-triggered exonuclease III-assisted target recycling and DNAzyme amplification.

    Science.gov (United States)

    Ren, Wang; Zhang, Ying; Huang, Wei Tao; Li, Nian Bing; Luo, Hong Qun

    2015-06-15

    This work reported a label-free colorimetric assay for sensitive detection of Hg(2+) based on Hg(2+)-triggered hairpin DNA probe (H-DNA) termini-binding and exonuclease Ш (Exo Ш)-assisted target recycling, as well as hemin/G-quadruplex (DNAzyme) signal amplification. The specific binding of free Hg(2+) with the thymine-thymine (T-T) mismatches termini of H-DNA could immediately trigger the Exo Ш digestion, and then set free G-quadruplex segments and Hg(2+). The Exo Ш impellent recycling of ultratrace Hg(2+) produced numerous G-quadruplexes. The corresponding DNAzymes catalyzed efficiently the H2O2-mediated oxidation of the ABTS(2-) to the colored product in the presence of hemin. Using the color change as the output signal, and the Exo Ш-aided Hg(2+) recycling and DNAzyme as the signal amplifier, the ultrasensitive assay system successfully achieved visual detection of Hg(2+) as low as 1.0 nM by the naked eye, and was suitable for field monitoring. The calibration curve was linear in the range of 50.0 pM to 20.0 nM for Hg(2+) (R=0.9962) with a detection limit of 10.0 pM. Moreover, this proposed strategy showed excellent selectivity, portability and low-cost, and was successfully applied to colorimetric detection of Hg(2+) in laboratory tap water and Jialing river water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Lamps and lighting

    CERN Document Server

    Cayless, MA; Marsden, A M

    2012-01-01

    This book is a comprehensive guide to the theory and practice of lighting. Covering the physics of light production, light sources, circuits and a wide variety of lighting applications, it is both suitable as a detailed textbook and as thoroughly practical guide for practising lighting engineers. This fourth edition of Lamps and Lighting has been completely updated with new chapters on the latest lamp technology and applications. The editors ahve called upon a wide range of expertise and as a result many sections have been broadened to include both European and US practice.The book begins with

  7. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic blood pressure, respectively. The concordance of BP variation at the two measurement sites was clinically acceptable. DPA pressure and vascular resistance in the lower limb decreased gradually during surgery. DPA pressure tends to be lower than arm pressure under sevoflurane anesthesia, especially the mean blood pressure and the diastolic blood pressure. Hence, noninvasive arm BP monitoring is recommend to be retained when invasive BP is measured at the DPA, so as to allow clinicians to comprehensively evaluate the BP condition of the patients and make appropriate therapeutic decisions.

  8. Different antihypertensive effect of beta-blocking drugs in low and normal-high renin hypertension.

    Science.gov (United States)

    Kralberg, B E; Tolagen, K

    1976-05-31

    The treatment response to beta-adrenoceptor blocking drugs was compared in two groups of patients with primary (essential) hypertension and different renin levels. Each group consisted of 25 patients and was equally distributed regarding age, severity and stage of hypertension. In the first group (group 1), the mean upright plasma renin activity was 0.8 ng ml-1h-1 (range 0.3 to 1.5) and the patients were considered to have low renin hypertension. In the other group (group 2) the patients had a mean plasma renin activity of 2.1 ng ml-1h-1 (range 1.1 to 5.1) and were considered to have normal to high renin hypertension. In both groups the patients were initially treated with beta-blocking drugs; in group 1 with a beta-blocker corresponding to an average dose of 311 mg propranolol a day for at least eight weeks and in group 2 with propranolol 320 mg a day in a fixed dose for eight weeks. The hypotensive response differed significantly between the two groups (p less than 0.001). In group 1 the pretreatment blood pressure was 197/117 mm Hg supine and 198/120 mm Hg standing. During treatment blood pressure decreased only 5/3 mm Hg supine and 9/5 mm Hg standing. The pretreatment blood pressure in group 2 was 187/114 mm Hg supine and 186/117 mm Hg standing. Beta-blocking therapy reduced blood pressure 36/23 and 34/18 mm Hg, respectively (both p less than 0.001). Pulse rates fell significantly in the two groups, both in the lying and standing positions. In 17 patients with low renin hypertension (group 1), a volume-depleting drug was added (spironolactone, 14 patients; thiazides, 3 patients) and this achieved a marked fall in blood pressure levels of 38/16 mm Hg supine and 37/19 mm Hg standing (both p less than 0.001). These results suggest the following: (1) Most patients with normal to high plasma renin activity respond well to moderate doses of propranolol. (2) Propranolol given in the same doses is almost without antihypertensive effect in patients with low renin

  9. THE YIELD OF LETTUCE BREEDING LINE UNDER LED LAMPS IN WINTER GREENHOUSE IN THE NORTH

    Directory of Open Access Journals (Sweden)

    I. V. Dalke

    2017-01-01

    Full Text Available The lettuce (Lactuca sativa L. is widely known and favorite vegetable crop among people. In Europe the main production of lettuce is performed on protected ground with application of  artificial  light  sources. The artificially-lighted  culture  of salad became very actually acquired in the north. Previously, on the basis of multi-year studies on yield registration and experiments with different regimes of lighting we have defined the appropriate parameters of supplementary lighting for lettuce with sodium high-pressure lamps that provided the production in different seasons per year. The aim was to study the accumulation of biomass and yield quality in lettuce ‘Aphytsion’ being grown in winter rotation under light-emitting diodes lamps. The accumulation of biomass and yield quality was studied in ‘Aphytsion’,  grown in winter rotation under lightemitting diodes lamps ECOLED-BIO-112-185WD120 UniversaLED (ООО ‘GK’  ‘CET’, Perm, in  industrial greenhouse OOO ‘Prigorodniy’  at Syktyvkar city. The commodity  output  was obtained  for  two  cycle  of  cultivation, November-December  and  December-January.  Yield  of foliage biomass was 2.4 kg/m2 with flow density PAR (Photosynthetically active radiation about 90 μmole quantum/m2  s. at 20 W/m2 with total light energy 54 MJ/m2  supplied to plants from LED lamps. The plants produced about 0.5 g. of dry weight calculated on one mole of spent light energy. Energy efficiency of PAR was 3% that corresponded with data observed earlier with sodium high-pressure lamps. The conclusion was made about the suitableness of this type of light-emitting diode lamps for lettuce cultivation in winter rotation in first photic zone. It was recommended to increase duration of supplemental lighting up to 22-24 hours in December and up to 20-22 hours in January to improve the productivity and biological value of plant output. It enables to raise RAP income in plants by 35 %, on

  10. The measurement of digital systolic blood pressure by strain gauge technique

    DEFF Research Database (Denmark)

    Nielsen, P E; Bell, G; Lassen, N A

    1972-01-01

    The systolic blood pressure on the finger, toe, and ankle has been measured by a strain gauge technique in 10 normal subjects aged 17-31 years and 14 normal subjects aged 43-57 years. The standard deviation in repeated measurements lies between 2 and 6 mm Hg. The finger pressure in the younger...... group was significantly higher than the corresponding arm pressure (+ 9.3 mm Hg, S.D. 6.8), but equalled this in the older group (- 0.5 mm Hg, S.D. 6.6). In the two groups the ankle pressures were + 19.3 mm Hg (S.D. 7.5) and + 23.6 mm Hg (S.D. 9.5) higher than the systolic arm pressures. The toe...... pressures were lower than the arm pressures, in the two groups - 4.8 mm Hg (S.D. 6.6) and - 9.8 mm Hg (S.D. 10.7) respectively. The ankle-toe gradient was in the younger group 24.3 mm Hg (S.D. 7.3) and in the older group 33.3 mm Hg (S.D. 12.1). Using mean minus 2.5 X S.D. as the lower limit of normality...

  11. Application of Wireless Intelligent Control System for HPS Lamps and LEDs Combined Illumination in Road Tunnel

    Science.gov (United States)

    Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo

    2014-01-01

    Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266

  12. Intracellular Hg(0) Oxidation in Desulfovibrio desulfuricans ND132.

    Science.gov (United States)

    Wang, Yuwei; Schaefer, Jeffra K; Mishra, Bhoopesh; Yee, Nathan

    2016-10-03

    The disposal of elemental mercury (Hg(0)) wastes in mining and manufacturing areas has caused serious soil and groundwater contamination issues. Under anoxic conditions, certain anaerobic bacteria can oxidize dissolved elemental mercury and convert the oxidized Hg to neurotoxic methylmercury. In this study, we conducted experiments with the Hg-methylating bacterium Desulfovibrio desulfuricans ND132 to elucidate the role of cellular thiols in anaerobic Hg(0) oxidation. The concentrations of cell-surface and intracellular thiols were measured, and specific fractions of D. desulfuricans ND132 were examined for Hg(0) oxidation activity and analyzed with extended X-ray absorption fine structure (EXAFS) spectroscopy. The experimental data indicate that intracellular thiol concentrations are approximately six times higher than those of the cell wall. Cells reacted with a thiol-blocking reagent were severely impaired in Hg(0) oxidation activity. Spheroplasts lacking cell walls rapidly oxidized Hg(0) to Hg(II), while cell wall fragments exhibited low reactivity toward Hg(0). EXAFS analysis of spheroplast samples revealed that multiple different forms of Hg-thiols are produced by the Hg(0) oxidation reaction and that the local coordination environment of the oxidized Hg changes with reaction time. The results of this study indicate that Hg(0) oxidation in D. desulfuricans ND132 is an intracellular process that occurs by reaction with thiol-containing molecules.

  13. Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25.

    Science.gov (United States)

    Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan

    2013-11-01

    The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.

  14. A Structural Study of the Pseudo-Binary Mercury Chalcogenide Alloy HgSe_{0.7}S_{0.3} at High Pressure

    CERN Document Server

    Kozlenko, D P; Ehm, L; Knorr, K; Hull, S; Shchennikov, V V; Voronin, V I

    2002-01-01

    The structure of the pseudo-binary mercury chalcogenide alloy HgSe_{0.7}S_{0.3} has been studied by means of X-ray and neutron powder diffraction at pressure up to 8.5 GPa. A phase transition from the cubic zinc blende structure to the hexagonal cinnabar structure was observed at P{\\sim}1 GPa. The obtained structural parameters were used for the analysis of the geometrical relationship between the zinc blende and the cinnabar phases. The zinc blende-cinnabar phase transition is discussed in the framework of Landau theory of the phase transitions. It was found that the possible order parameter for the structural transformation is the spontaneous strain e_{4}. This assignment agrees with previously observed high pressure behaviour of the elastic constants of other mercury chalcogenides.

  15. A structural study of the pseudo-binary mercury chalcogenide alloy HgSe0.7S0.3 at high pressure

    International Nuclear Information System (INIS)

    Kozlenko, D.P.; Savenko, B.N.; Ehm, L.; Knorr, K.; Hull, S.; Shchennikov, V.V.; Voronin, V.I.

    2002-01-01

    The structure of the pseudo-binary mercury chalcogenide alloy HgSe 0.7 S 0.3 has been studied by means of X-ray and neutron powder diffraction at pressure up to 8.5 GPa. A phase transition from the cubic zinc blende structure to the hexagonal cinnabar structure was observed at P∼1 GPa. The obtained structural parameters were used for the analysis of the geometrical relationship between the zinc blende and the cinnabar phases. The zinc blende-cinnabar phase transition is discussed in the framework of the Landau theory of phase transitions. It was found that the possible order parameter for the structural transformation is the spontaneous strain e 4 . This assignment agrees with previously observed high pressure behaviour of the elastic constants of other mercury chalcogenides

  16. Photoreduction of carbon dioxide and water into formaldehyde and methanol on semiconductor materials

    Energy Technology Data Exchange (ETDEWEB)

    Aurian-Blajeni, B; Halmann, M; Manassen, J

    1980-01-01

    Heterogeneous photoassisted reduction of aqueous carbon dioxide was achieved using semiconductor powders, with either high-pressure Hg-lamps or sunlight as energy sources. The products were methanol, formaldehyde and methane. The reaction was carried out either as a gas-solid process, by passing carbon dioxide and water vapor over illuminated semiconductor surfaces, or as a liquid-solid reaction, by illuminating aqueous suspensions of semiconductor powders through which carbon dioxide was bubbled. Best results, under illumination by Hg-lamps, were obtained with aqueous suspensions of strontium titanate, SrTiO3, tungsten oxide, WO3, and titanium oxide, TiO2, resulting in absorbed energy conversion efficiencies of 6, 5.9 and 1.2 per cent, respectively.

  17. Fluorescent and high intensity discharge lamp use in chambers and greenhouses

    Energy Technology Data Exchange (ETDEWEB)

    Langhans, R.W. [Cornell Univ., Ithaca, NY (United States)

    1994-12-31

    Fluorescent and High Intensity Discharge lamps have opened up great opportunities for researchers to study plant growth under controlled environment conditions and for commercial growers to increase plant production during low/light periods. This report describes the advantages and disadvantages of using each lamp in growth chambers, growth rooms and greenhouses. Growth Chambers are small (3m x 4/m and smaller) walk-in or reach-in enclosures with programmable, accurate temperature, relative humidity (RH) and irradiance control over wide ranges. The intent of growth chambers was to replicate sunlight conditions and transfer research results directly to the greenhouse or outside. It was realized that sunlight and outside conditions could not be mimicked. Growth chambers are also used to study irradiance and spectral fluxes. Growth Rooms are usually large rooms (larger than 3m x 4m) with only lamp irradiance, but providing relatively limited ranges of environmental control (i.e., 10 to 30 C temperature, 50 to 90% RH and ambient to 1000 ppm CO{sub 2}), and commonly independent of outside conditions. Irradiance requirements for growth rooms are similar to those of growth chambers. Growth rooms are also used for growing a large number of plants in a uniform standard environment condition and in commercial horticulture for tissue culture, seed germination (plugs) and seedling growth. Greenhouses are designed to allow maximum sunlight penetration through the structure. Initially greenhouses were used to extend the growing season. Then as heating systems, and cooling systems improved, they were used year round. Low light during the winter months reduced plant growth, but with the advent of efficient lamps (HID and fluorescent) it became possible to increase growth to rates close to that in summer months. Supplementary lighting is used during low light periods of the year and anytime to ensure consistent total daily irradiance for research plants.

  18. Lamp reliability studies for improved satellite rubidium frequency standard

    Science.gov (United States)

    Frueholz, R. P.; Wun-Fogle, M.; Eckert, H. U.; Volk, C. H.; Jones, P. F.

    1982-01-01

    In response to the premature failure of Rb lamps used in Rb atomic clocks onboard NAVSTAR GPS satellites experimental and theoretical investigations into their failure mechanism were initiated. The primary goal of these studies is the development of an accelerated life test for future GPS lamps. The primary failure mechanism was identified as consumption of the lamp's Rb charge via direct interaction between Rb and the lamp's glass surface. The most effective parameters to accelerate the interaction between the Rb and the glass are felt to be RF excitation power and lamp temperature. Differential scanning calorimetry is used to monitor the consumption of Rb within a lamp as a function of operation time. This technique yielded base line Rb consumption data for GPS lamps operating under normal conditions.

  19. KATP channels are not essential for pressure-dependent control of renin secretion

    DEFF Research Database (Denmark)

    Jensen, B L; Gambaryan, S; Scholz, H

    1998-01-01

    (IPRK). Cromakalim (0.1-10 muM) stimulated basal renin secretion up to threefold and caused vasorelaxation in the IPRK. Both effects of cromakalim were attenuated by glibenclamide. Cromakalim stimulated renin secretion from isolated juxtaglomerular (JG) cells and from microdissected afferent arterioles......This study aimed to investigate the functional role of ATP-sensitive K+ (KATP) channels in the control of renin secretion by renal perfusion pressure. We studied the effect of openers and blockers of KATP-channels on basal- and low-pressure-induced renin secretion from isolated perfused rat kidneys......, all of which suggests that KATP channel openers stimulate renin secretion at the level of JG cells. A decrease in the perfusion pressure from 13.3 to 9.33 kPa (100 mmHg to 70 mmHg) increased renin secretion twofold, and cromakalim further increased renin secretion. At 5.33 kPa (40 mmHg) renin...

  20. GMO detection using a bioluminescent real time reporter (BART of loop mediated isothermal amplification (LAMP suitable for field use

    Directory of Open Access Journals (Sweden)

    Kiddle Guy

    2012-04-01

    Full Text Available Abstract Background There is an increasing need for quantitative technologies suitable for molecular detection in a variety of settings for applications including food traceability and monitoring of genetically modified (GM crops and their products through the food processing chain. Conventional molecular diagnostics utilising real-time polymerase chain reaction (RT-PCR and fluorescence-based determination of amplification require temperature cycling and relatively complex optics. In contrast, isothermal amplification coupled to a bioluminescent output produced in real-time (BART occurs at a constant temperature and only requires a simple light detection and integration device. Results Loop mediated isothermal amplification (LAMP shows robustness to sample-derived inhibitors. Here we show the applicability of coupled LAMP and BART reactions (LAMP-BART for determination of genetically modified (GM maize target DNA at low levels of contamination (0.1-5.0% GM using certified reference material, and compare this to RT-PCR. Results show that conventional DNA extraction methods developed for PCR may not be optimal for LAMP-BART quantification. Additionally, we demonstrate that LAMP is more tolerant to plant sample-derived inhibitors, and show this can be exploited to develop rapid extraction techniques suitable for simple field-based qualitative tests for GM status determination. We also assess the effect of total DNA assay load on LAMP-BART quantitation. Conclusions LAMP-BART is an effective and sensitive technique for GM detection with significant potential for quantification even at low levels of contamination and in samples derived from crops such as maize with a large genome size. The resilience of LAMP-BART to acidic polysaccharides makes it well suited to rapid sample preparation techniques and hence to both high throughput laboratory settings and to portable GM detection applications. The impact of the plant sample matrix and genome loading

  1. Risk Stratification by Ambulatory Blood Pressure Monitoring Across JNC Classes of Conventional Blood Pressure

    DEFF Research Database (Denmark)

    Brguljan-Hitij, Jana; Thijs, Lutgarde; Li, Yan

    2014-01-01

    BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (<120/<80 mm Hg), prehypertension (120-139/80-89 mm Hg), and hypertension (≥140/≥90 mm Hg). METHODS: To assess the potential differential contribution of ambulatory blood pressure (ABP) in predict......BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (ABP......%) and of cardiovascular (-34%), cardiac (-33%), or cerebrovascular (-47%) events. Multivariable-adjusted hazard ratios (HRs) for stroke associated with 24-hour and daytime diastolic ABP (+5 mm Hg) were higher (P ≤ 0.045) in normotension than in prehypertension and hypertension (1.98 vs.1.19 vs.1.28 and 1.73 vs.1.09 vs. 1.......24, respectively) with similar trends (0.03 ≤ P ≤ 0.11) for systolic ABP (+10 mm Hg). However, HRs for fatal endpoints and cardiac events associated with ABP did not differ significantly (P ≥ 0.13) across CBP categories. Of normotensive and prehypertensive participants, 7.5% and 29.3% had masked hypertension...

  2. Optimized positioning of autonomous surgical lamps

    Science.gov (United States)

    Teuber, Jörn; Weller, Rene; Kikinis, Ron; Oldhafer, Karl-Jürgen; Lipp, Michael J.; Zachmann, Gabriel

    2017-03-01

    We consider the problem of finding automatically optimal positions of surgical lamps throughout the whole surgical procedure, where we assume that future lamps could be robotized. We propose a two-tiered optimization technique for the real-time autonomous positioning of those robotized surgical lamps. Typically, finding optimal positions for surgical lamps is a multi-dimensional problem with several, in part conflicting, objectives, such as optimal lighting conditions at every point in time while minimizing the movement of the lamps in order to avoid distractions of the surgeon. Consequently, we use multi-objective optimization (MOO) to find optimal positions in real-time during the entire surgery. Due to the conflicting objectives, there is usually not a single optimal solution for such kinds of problems, but a set of solutions that realizes a Pareto-front. When our algorithm selects a solution from this set it additionally has to consider the individual preferences of the surgeon. This is a highly non-trivial task because the relationship between the solution and the parameters is not obvious. We have developed a novel meta-optimization that considers exactly this challenge. It delivers an easy to understand set of presets for the parameters and allows a balance between the lamp movement and lamp obstruction. This metaoptimization can be pre-computed for different kinds of operations and it then used by our online optimization for the selection of the appropriate Pareto solution. Both optimization approaches use data obtained by a depth camera that captures the surgical site but also the environment around the operating table. We have evaluated our algorithms with data recorded during a real open abdominal surgery. It is available for use for scientific purposes. The results show that our meta-optimization produces viable parameter sets for different parts of an intervention even when trained on a small portion of it.

  3. Studies of the 198Hg(d,d') and 198Hg(d,p) reactions

    Science.gov (United States)

    Diaz Varela, Alejandra; Garrett, P. E.; Rand, E. T.; Ball, G. C.; Bilstein, V.; Laffoley, A. T.; Maclean, A. D.; Svensson, C. E.; Faestermann, T.; Hertenberger, R.; Wirth, H.-F.

    2017-09-01

    Limits on the electric dipole moment (EDM) continue to decrease for 199Hg, the most stringent upper limit for a nuclear EDM to date. The experimental limit on the observed atomic EDM for 199Hg is converted to a limit on the nuclear EDM via a calculation of the Schiff moment, requiring knowledge of the nuclear structure of 199Hg. The E 3 and E 1 strength distributions to the ground state of 199Hg, and E 2 transitions amongst excited states, would be ideal information to further constrain 199Hg Schiff moment theoretical models. The high level density of 199Hg makes those determinations challenging, however the similar information can be obtained from exploring surrounding even-even Hg isotopes. As part of a campaign to study the Hg isotopes near 199Hg, two experiments, 198Hg(d,d') 198Hg and 198Hg(d,p)199Hg reaction were performed using the Q3D spectrograph at the Maier-Leibnitz Laboratory (MLL) at Garching, Germany. A 22 MeV deuterium beam was used to impinge a 198Hg32S target. The (d,d') reaction allows us to probe the desired E 2 and E 3 matrix elements, while the (d,p) reaction provides information on the neutron single-particle states of 199Hg.

  4. A new approach to the evaluation of the discharge parameters of the electrodeless fluorescent lamps

    International Nuclear Information System (INIS)

    Statnic, Eugen; Tanach, Valentin

    2004-01-01

    A new model was developed for the characterization and quantification of the 'inaccessible' discharge parameters in closed tube high power electrodeless fluorescent lamps. The results obtained applying the model are verifiable by means of a simple comparison of the primary equivalent resistance and reactance as a result of the measured V 1 , I 1 , ψ 1 with the equivalent primary resistance and reactance inferred from the proposed model. The results are in good agreement at all operating lamp power levels. What is unexpected is the capacitive behaviour of the inductive coupled plasma at lower powers. The investigation method is suitable for the optimization of high power electrodeless lamps with a long discharge path operated at low frequencies, in order to improve the efficiency and the system stability, especially if the lamp has to be dimmed

  5. A pulse generator for xenon lamps

    CERN Document Server

    Janata, E

    2002-01-01

    A pulse generator is described, which enhances the analyzing light emitted from a xenon lamp as used in kinetic photospectrometry experiments. The lamp current is increased to 600 A for a duration of 3 ms; the current is constant within +-0.2% during a time interval of 2 ms. Because of instabilities of the lamp arc during pulsing, the use of the enhanced light source is limited to measuring times up to 500 mu s. The enhancement in light intensity depends on the wavelength and amounts to more than 400-fold in the UV-region.

  6. Dietary Interventions and Blood Pressure in Latin America - Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Erbano, Bruna Olandoski [Faculdade Evangélica do Paraná, Curitiba, PR (Brazil); Schio, Nicolle Amboni; Guarita-Souza, Luiz César; Olandoski, Marcia; Faria-Neto, José Rocha, E-mail: jrochafaria@cardiol.br; Baena, Cristina Pellegrino [Pontifícia Universidade Católica do Paraná (PUC-PR), Curitiba, PR (Brazil)

    2014-04-15

    High blood pressure is the major risk factor for cardiovascular disease. Low blood pressure control rates in Latin American populations emphasize the need for gathering evidence on effective therapies. To evaluate the effects of dietary interventions on blood pressure in Latin American populations. Systematic review. Electronic databases (MEDLINE/PubMed, Embase, Cochrane Library, CINAHL, Web of Science, Scopus, SciELO, LILACS and VHL) were searched and manual search for studies published up to April 2013 was performed. Parallel studies about dietary interventions in Latin American adult populations assessing arterial blood pressure (mm Hg) before and after intervention were included. Of the 405 studies identified, 10 randomized controlled trials were included and divided into 3 subgroups according to the proposed dietary intervention. There was a non-significant reduction in systolic blood pressure in the subgroups of mineral replacement (-4.82; 95% CI: -11.36 to 1.73) and complex pattern diets (-3.17; 95% CI: -7.62 to 1.28). Regarding diastolic blood pressure, except for the hyperproteic diet subgroup, all subgroups showed a significant reduction in blood pressure: -4.66 mmHg (95% CI: -9.21 to -0.12) and -4.55 mmHg (95% CI: -7.04 to -2.06) for mineral replacement and complex pattern diets, respectively. Available evidence on the effects of dietary changes on blood pressure in Latin American populations indicates a homogeneous effect of those interventions, although not significant for systolic blood pressure. Samples were small and the quality of the studies was generally low. Larger studies are required to build robust evidence.

  7. Dietary Interventions and Blood Pressure in Latin America - Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Erbano, Bruna Olandoski; Schio, Nicolle Amboni; Guarita-Souza, Luiz César; Olandoski, Marcia; Faria-Neto, José Rocha; Baena, Cristina Pellegrino

    2014-01-01

    High blood pressure is the major risk factor for cardiovascular disease. Low blood pressure control rates in Latin American populations emphasize the need for gathering evidence on effective therapies. To evaluate the effects of dietary interventions on blood pressure in Latin American populations. Systematic review. Electronic databases (MEDLINE/PubMed, Embase, Cochrane Library, CINAHL, Web of Science, Scopus, SciELO, LILACS and VHL) were searched and manual search for studies published up to April 2013 was performed. Parallel studies about dietary interventions in Latin American adult populations assessing arterial blood pressure (mm Hg) before and after intervention were included. Of the 405 studies identified, 10 randomized controlled trials were included and divided into 3 subgroups according to the proposed dietary intervention. There was a non-significant reduction in systolic blood pressure in the subgroups of mineral replacement (-4.82; 95% CI: -11.36 to 1.73) and complex pattern diets (-3.17; 95% CI: -7.62 to 1.28). Regarding diastolic blood pressure, except for the hyperproteic diet subgroup, all subgroups showed a significant reduction in blood pressure: -4.66 mmHg (95% CI: -9.21 to -0.12) and -4.55 mmHg (95% CI: -7.04 to -2.06) for mineral replacement and complex pattern diets, respectively. Available evidence on the effects of dietary changes on blood pressure in Latin American populations indicates a homogeneous effect of those interventions, although not significant for systolic blood pressure. Samples were small and the quality of the studies was generally low. Larger studies are required to build robust evidence

  8. Dietary interventions and blood pressure in Latin America - systematic review and meta-analysis.

    Science.gov (United States)

    Mazzaro, Caroline Cantalejo; Klostermann, Flávia Caroline; Erbano, Bruna Olandoski; Schio, Nicolle Amboni; Guarita-Souza, Luiz César; Olandoski, Marcia; Faria-Neto, José Rocha; Baena, Cristina Pellegrino

    2014-04-01

    High blood pressure is the major risk factor for cardiovascular disease. Low blood pressure control rates in Latin American populations emphasize the need for gathering evidence on effective therapies. To evaluate the effects of dietary interventions on blood pressure in Latin American populations. Systematic review. Electronic databases (MEDLINE/PubMed, Embase, Cochrane Library, CINAHL, Web of Science, Scopus, SciELO, LILACS and VHL) were searched and manual search for studies published up to April 2013 was performed. Parallel studies about dietary interventions in Latin American adult populations assessing arterial blood pressure (mm Hg) before and after intervention were included. Of the 405 studies identified, 10 randomized controlled trials were included and divided into 3 subgroups according to the proposed dietary intervention. There was a non-significant reduction in systolic blood pressure in the subgroups of mineral replacement (-4.82; 95% CI: -11.36 to 1.73) and complex pattern diets (-3.17; 95% CI: -7.62 to 1.28). Regarding diastolic blood pressure, except for the hyperproteic diet subgroup, all subgroups showed a significant reduction in blood pressure: -4.66 mmHg (95% CI: -9.21 to -0.12) and -4.55 mmHg (95% CI: -7.04 to -2.06) for mineral replacement and complex pattern diets, respectively. Available evidence on the effects of dietary changes on blood pressure in Latin American populations indicates a homogeneous effect of those interventions, although not significant for systolic blood pressure. Samples were small and the quality of the studies was generally low. Larger studies are required to build robust evidence.

  9. 46 CFR 53.12-1 - General (modifies HG-600 through HG-640).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false General (modifies HG-600 through HG-640). 53.12-1... HEATING BOILERS Instruments, Fittings, and Controls (Article 6) § 53.12-1 General (modifies HG-600 through HG-640). (a) The instruments, fittings and controls for heating boilers shall be as indicated in HG...

  10. Study on residential appliances energy efficiency standards Refrigerators, air-conditioners, incandescent lamps, fluorescent lamps, color TVs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.G.; Cho, S.K.; Choi, S.H.; Jung, B.M.; Han, S.B.; Kim, K.D. [Korea Inst. of Energy Research, Taejon (Korea, Republic of)

    1995-12-01

    The energy efficiency standards and rating act, as amended by the rational energy utilization act, provides energy efficiency standards and ratings for 6 types of consumer products(refrigerators, air-conditioners, fluorescent lamps, incandescent lamps, ballasts and cars) authorizes the Ministry of Trade, Industry and Energy(MOTIE) to prescribe amended or new energy efficiency standards and rating standards. This study was initiated by the KIER in 1992. KIER`s assessment of the standards is designed to evaluate their statistical and engineering analysis according to Korean(Industrial) Standards(KS). And to make distinction between the poor efficiency and good efficiency models, 5 grades are classified depending on their tested energy efficiency. This year, based on our analysis, MOTIE mandated updated standards for refrigerators, air-conditioners, incandescent lamps, and fluorescent lamps. Also the objective of this study is to set the energy efficiency standards and to grade for color TV sets. (author). 37 refs., 89 figs., 85 tabs.

  11. Synthesis of silver nanoparticles by radiolysis, photolysis and chemical reduction of AgNO3 in Hibiscus sabdariffa infusion (karkade)

    International Nuclear Information System (INIS)

    Cataldo, Franco; Ursini, Ornella; Angelini, Giancarlo

    2016-01-01

    Silver nanoparticles of different average diameters were synthesized by γ-radiolysis, UV-photolysis and chemical reduction of AgNO 3 solutions in Hibiscus sabdariffa infusion commonly known as 'karkade'. The UV-photolysis was performed either by using a conventional Hg low pressure lamp emitting at 254 nm and also by using a new compact UV-LED source emitting at 360 nm. The kinetics rate constant of silver nanoparticles synthesis produced by γ-radiolysis and UV photolysis were determined and the average diameter of the resulting nanoparticles was estimated. (author)

  12. History of HgTe-based photodetectors in Poland

    Science.gov (United States)

    Rogalski, A.

    2010-09-01

    In Poland, the HgCdTe studies began in 1960 at the Institute of Physics, Warsaw University. The material processing laboratory was created by Giriat and later by Dziuba, Gałązka, and others. Bridgman technique with sealed thick wall quartz ampoules was used to grow material suitable for research and experimental devices. Among the first papers published in 1961 and 1963 there were the Polish works devoted to preparation, doping, and electrical properties of HgCdTe. Infrared detector's research and development efforts in Poland were concentrated mostly on uncooled market niche. At the beginning, a modified isothermal vapour phase epitaxy has been used for research and commercial fabrication of photoconductive, photoelectromagnetic and other HgCdTe devices. Bulk growth and liquid phase epitaxy were also used. Recently, the fabrication of infrared devices relies on low temperature epitaxial technique, namely metalorganic vapour phase deposition. At present stage of development, the photoconductive and photoelectromagnetic (PEM) detectors are gradually replaced with photovoltaic devices which offer inherent advantages of no electric or magnetic bias, no heat load and no flicker noise. Potentially, photodiodes offer high performance and very fast response. However, conventional photovoltaic uncooled detectors suffer from low quantum efficiency and very low junction resistance. The problems have been solved with advanced band gap engineered architecture, multiple cell heterojunction devices connected in series, and monolithic integration of the detectors with microoptics. In final part of the paper, the Polish achievements in technology and performance of HgMnTe and HgZnTe photodetectors are presented.

  13. Developing low-cost carbon-based sorbents for Hg capture from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Perry, R.; Lakatos, J.; Snape, C.E.; Sun, C. [University of Nottingham, Nottingham (United Kingdom). Nottingham Fuel and Energy Centre

    2005-07-01

    To help reduce the cost of Hg capture from flue gas a number of low-cost carbons are being investigated, including activated tyre char and PFA carbon, in conjunction with some of the pre-treatments that have been found to be effective for commercial actived carbons. Experimental conditions for screening the sorbents have been selected to determine breakthrough capacities rapidly. The unactivated carbons have low breakthrough capacities under the test conditions employed (around 0.1 mg g{sup -1}) but these improve upon steam activation (around 0.25 mg g{sup -1}) but are still lower than those of non-impregnated commercial activated carbons (around 0.4-0.7 mg g{sup -1}), due to their lower surface areas. Comparable improvements to the commercial carbons have been achieved for impregnation treatments, including sulfur and bromine. However, certain gasification chars do have much higher breakthrough capacities than commercial carbons used for flue gas injection. Manganese oxide impregnation with low concentration is particularly effective for the activated and unactivated carbons giving breakthrough capacities comparable to the commercial carbons. Pointers for further increasing breakthrough and equilibrium capacities for carbon-based sorbents are discussed. 7 refs., 1 fig., 3 tabs.

  14. Characteristics of a nanosecond-barrier-discharge-pumped multiwave UV – VUV lamp on a mixture of argon, krypton and vapours of freon

    Energy Technology Data Exchange (ETDEWEB)

    Shuaibov, A K; Minya, A I; Hrytsak, R V; Gomoki, Z T [Uzhgorod National University, Uzhgorod (Ukraine)

    2015-02-28

    We present the results of investigation of the characteristics of a nanosecond-barrier-discharge-pumped multiwave lamp based on a gas mixture of Ar – Kr – CCl{sub 4}, which emits in the spectral range of 170 – 260 nm. The main emission bands in the lamp spectrum are ArCl (B → X) near 175 nm, KrCl (B → X) near 222 nm and Cl{sub 2} (D' → A') near 258 nm. The lamp intensity with respect to pressure, working mixture composition and pump regime is optimised. (uv - vuv emitters)

  15. Quadrupole moments of the 12+ isomers in 188Hg and 190Hg

    International Nuclear Information System (INIS)

    Dracoulis, G.D.; Lonnroth, T.; Vajda, S.; Dafni, E.; Schatz, G.

    1984-01-01

    The electric quadrupole interaction of the 12 + isomers in 188 Hg and 190 Hg has been measured in solid Hg. The quadrupole moments deduced, vertical strokeQ[ 188 Hg(12 + )]vertical stroke = 91(11) e fm 2 and vertical strokeQ[ 190 Hg(12 + )]vertical stroke = 117(14) e fm 2 suggest a possible change in γ-deformation due to the rotation alignment of the isub(13/2) quasi-neutrons. The temperature dependence of the electric field gradient tensor in Hg was also determined. (orig.)

  16. Mechanisms of Hg(II) uptake and methylation in methylating bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Morel, Francois M. M. [Princeton Univ., NJ (United States). Geosciences

    2016-10-14

    The goal of this project was to understand the critical factors which control the availability and transport of Hg(II) into cells, a first step in the production of the neurotoxin, methylmercury. Specifically, this research focused on understanding the mechanism of bacterial mercury uptake and how mercury speciation affects the specificity and kinetics of mercury transport. Our research has shown that Hg(II) uptake in three different iron and sulfate-reducing proteobacteria occurs by the following mechanism (1) : Hg(II) uptake is an active transport process requiring energy, (2) it is dependent upon the structure of the Hg binding ligand, and (3) it is mediated by a heavy metal transporter such as one which transports the essential metal, Zn(II). In order to determine whether this mechanism extends to more diverse phylogenetic groups, we have begun examining Hg(II) uptake and bioavailability in two representative Hg methylating strains within the Firmicutes. These organisms have remarkably different membrane structures distinct from the Proteobacteria. Our results show low uptake rates in these two species of Firmicutes relative to the previously characterized Proteobacteria. This may explain the low methylation rates and yields observed in these organisms. Most surprisingly, however, these organisms appear to take up Hg(II) passively, as the addition of a protonophore failed to reduce Hg(II) uptake in these organisms. This is quite different to what has been observed previously for the Proteobacteria and suggests a different mechanism for Hg(II) uptake in the Firmicutes. We are continuing to understand and describe Hg(II) uptake in these organisms. A manuscript is expected to be submitted on this research in June 2016.

  17. Intraperitoneal pressure: ascitic fluid and splanchnic vascular pressures, and their role in prevention and formation of ascites

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Stage, J G; Schlichting, P

    1980-01-01

    Seventeen patients with ascites due to cirrhosis underwent hepatic venous catheterization and pressure measurement in the ascitic fluid. Intraperitoneal fluid hydrostatic pressure (IFP) ranged 3.5-22, mean 11.2 mm Hg, and correlated closely to the pressure in the inferior vena cava (r = 0.97, P ... that ascitic fluid stems the pressures in the splanchnic venous vascular bed up to a higher level, but that the transmural hydrostatic pressure difference decreases simultaneously. The results are discussed in relation to the local 'oedema-preventing' mechanisms: (a) increased interstitial hydrostatic fluid.......001), which was on average 1.8 mmHg above that of ascitic fluid (P pressure (WHVP) (range 19-43, mean 32 mmHg) correlated directly to IFP (0.89, P

  18. Tracing aquatic bioavailable Hg in three different regions of China using fish Hg isotopes.

    Science.gov (United States)

    Liu, Cheng-Bin; Hua, Xiu-Bing; Liu, Hong-Wei; Yu, Ben; Mao, Yu-Xiang; Wang, Ding-Yong; Yin, Yong-Guang; Hu, Li-Gang; Shi, Jian-Bo; Jiang, Gui-Bin

    2018-04-15

    To trace the most concerned bioavailable mercury (Hg) in aquatic environment, fish samples were collected from three typical regions in China, including 3 rivers and 1 lake in the Tibetan Plateau (TP, a high altitude background region with strong solar radiation), the Three Gorges Reservoir (TGR, the largest artificial freshwater reservoir in China), and the Chinese Bohai Sea (CBS, a heavily human-impacted semi-enclosed sea). The Hg isotopic compositions in fish muscles were analyzed. The results showed that anthropogenic emissions were the main sources of Hg in fish from TGR and CBS because of the observed negative δ 202 Hg and positive Δ 199 Hg in these two regions (TGR, δ 202 Hg: - 0.72 to - 0.29‰, Δ 199 Hg: 0.15 - 0.52‰; CBS, δ 202 Hg: - 2.09 to - 0.86‰, Δ 199 Hg: 0.07 - 0.52‰). The relatively higher δ 202 Hg and Δ 199 Hg (δ 202 Hg: - 0.37 - 0.08‰, Δ 199 Hg: 0.50 - 1.89‰) in fish from TP suggested the insignificant disturbance from local anthropogenic activities. The larger slopes of Δ 199 Hg/Δ 201 Hg in fish from TGR (1.29 ± 0.14, 1SD) and TP (1.25 ± 0.06, 1SD) indicated methylmercury (MeHg) was produced and photo-reduced in the water column before incorporation into the fish. In contrast, the photoreduction of Hg 2+ was the main process in CBS (slope of Δ 199 Hg/Δ 201 Hg: 1.06 ± 0.06, 1SD). According to the fingerprint data of Hg isotopes, the most important source for aquatic bioavailable Hg in TP should be the long-range transported Hg, contrasting to the anthropogenic originated MeHg from surface sediments and runoffs in TGR and inorganic Hg from continental inputs in CBS. Therefore, the isotopic signatures of Hg in fish can provide novel clues in tracing sources and behaviors of bioavailable Hg in aquatic systems, which are critical for further understanding the biogeochemical cycling of Hg. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    Science.gov (United States)

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  20. Neutron Diffraction Study of the High-Tc Superconductor HgBa2CaCu2O6.3 under High Pressure

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Balagurov, A.M.; Savenko, B.N.; Capponi, J.J.; Glazkov, V.P.; Goncharenko, I.N.; Somenkov, V.A.

    1994-01-01

    The pressure dependence of the crystal structure of a powder sample of HgBa 2 CaCu 2 O 6.3 (T c =123 K) was studied in the pressure range of 0 to 3.6 GPa, using the DN-12 time-of-flight diffractometer at the IBR-2 pulsed reactor and a sapphire anvil cell chamber. At P=0 the results are in a good accordance with the published data. At P=3.0 and 3.6 GPa the best fit of the experimental data was achieved using the structural model with apical oxygen disordered in the (a,b) plane. The compressibility values of the lattice constants and selected bonds were calculated from the structural data. The highest absolute value of compressibility was found for the distance between the O atom layers. 12 refs., 6 figs., 3 tabs

  1. Photochemical reactions between mercury (Hg) and dissolved organic matter decrease Hg bioavailability and methylation.

    Science.gov (United States)

    Luo, Hong-Wei; Yin, Xiangping; Jubb, Aaron M; Chen, Hongmei; Lu, Xia; Zhang, Weihua; Lin, Hui; Yu, Han-Qing; Liang, Liyuan; Sheng, Guo-Ping; Gu, Baohua

    2017-01-01

    Atmospheric deposition of mercury (Hg) to surface water is one of the dominant sources of Hg in aquatic environments and ultimately drives methylmercury (MeHg) toxin accumulation in fish. It is known that freshly deposited Hg is more readily methylated by microorganisms than aged or preexisting Hg; however the underlying mechanism of this process is unclear. We report that Hg bioavailability is decreased by photochemical reactions between Hg and dissolved organic matter (DOM) in water. Photo-irradiation of Hg-DOM complexes results in loss of Sn(II)-reducible (i.e. reactive) Hg and up to an 80% decrease in MeHg production by the methylating bacterium Geobacter sulfurreducens PCA. Loss of reactive Hg proceeded at a faster rate with a decrease in the Hg to DOM ratio and is attributed to the possible formation of mercury sulfide (HgS). These results suggest a new pathway of abiotic photochemical formation of HgS in surface water and provide a mechanism whereby freshly deposited Hg is readily methylated but, over time, progressively becomes less available for microbial uptake and methylation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Equilibrium mercury isotope fractionation between dissolved Hg(II) species and thiol-bound Hg

    NARCIS (Netherlands)

    Wiederhold, Jan G.; Cramer, Christopher J.; Daniel, Kelly; Infante, Ivan; Bourdon, Bernard; Kretzschmar, Ruben

    2010-01-01

    Stable Hg isotope ratios provide a new tool to trace environmental Hg cycling. Thiols (-SH) are the dominant Hg-binding groups in natural organic matter. Here, we report experimental and computational results on equilibrium Hg isotope fractionation between dissolved Hg(II) species and thiol-bound

  3. 21 CFR 866.2600 - Wood's fluorescent lamp.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2600 Wood's fluorescent lamp. (a) Identification. A Wood's fluorescent lamp is a device intended for medical purposes to detect...

  4. [Remote Slit Lamp Microscope Consultation System Based on Web].

    Science.gov (United States)

    Chen, Junfa; Zhuo, Yong; Liu, Zuguo; Chen, Yanping

    2015-11-01

    To realize the remote operation of the slit lamp microscope for department of ophthalmology consultation, and visual display the real-time status of remote slit lamp microscope, a remote slit lamp microscope consultation system based on B/S structure is designed and implemented. Through framing the slit lamp microscope on the website system, the realtime acquisition and transmission of remote control and image data is realized. The three dimensional model of the slit lamp microscope is established and rendered on the web by using WebGL technology. The practical application results can well show the real-time interactive of the remote consultation system.

  5. 21 CFR 878.4635 - Ultraviolet lamp for tanning.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultraviolet lamp for tanning. 878.4635 Section 878... tanning. (a) Identification. An ultraviolet lamp for tanning is a device that is a lamp (including a fixture) intended to provide ultraviolet radiation to tan the skin. See § 1040.20 of this chapter. (b...

  6. Numerical investigation of symmetry breaking and critical behavior of the acoustic streaming field in high-intensity discharge lamps

    International Nuclear Information System (INIS)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2015-01-01

    For energy efficiency and material cost reduction it is preferred to drive high-intensity discharge lamps at frequencies of approximately 300 kHz. However, operating lamps at these high frequencies bears the risk of stimulating acoustic resonances inside the arc tube, which can result in low frequency light flicker and even lamp destruction. The acoustic streaming effect has been identified as the link between high frequency resonances and low frequency flicker. A highly coupled three-dimensional multiphysics model has been set up to calculate the acoustic streaming velocity field inside the arc tube of high-intensity discharge lamps. It has been found that the velocity field suffers a phase transition to an asymmetrical state at a critical acoustic streaming force. In certain respects the system behaves similar to a ferromagnet near the Curie point. It is discussed how the model allows to investigate the light flicker phenomenon. Concerning computer resources the procedure is considerably less demanding than a direct approach with a transient model. (paper)

  7. [Influence of cold spot temperature on 253.7 nm resonance spectra line of electrodeless discharge lamps].

    Science.gov (United States)

    Dong, Jin-yang; Zhang, Gui-xin; Wang, Chang-quan

    2012-01-01

    As a kind of new electric light source, electrodeless discharge lamps are of long life, low mercury and non-stroboscopic light. The lighting effect of electrodeless discharge lamps depends on the radiation efficiency of 253.7 nm resonance spectra line to a large extent. The influence of cold temperature on 253.7 nm resonance spectra line has been studied experimentally by atomic emission spectral analysis. It was found that the radiation efficiency of 253.7 nm resonance spectra line is distributed in a nearly normal fashion with the variation of cold spot temperature, in other words, there is an optimum cold spot temperature for an electrodeless discharge lamp. At last, the results of experiments were analyzed through gas discharge theory, which offers guidance to the improvement of lighting effect for electrodeless discharge lamps.

  8. Three Toxic Heavy Metals in Open-Angle Glaucoma with Low-Teen and High-Teen Intraocular Pressure: A Cross-Sectional Study from South Korea

    OpenAIRE

    Lee, Si Hyung; Kang, Eun Min; Kim, Gyu Ah; Kwak, Seung Woo; Kim, Joon Mo; Bae, Hyoung Won; Seong, Gong Je; Kim, Chan Yun

    2016-01-01

    Background To investigate the association between heavy metal levels and open-angle glaucoma (OAG) with low- and high-teen baseline intraocular pressure (IOP) using a population-based study design. Methods This cross-sectional study included 5,198 participants older than 19 years of age who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) from 2008 to 2012 and had blood heavy metal levels available. The OAG with normal baseline IOP (IOP ? 21 mmHg) subjects...

  9. The photoluminescence of a fluorescent lamp: didactic experiments on the exponential decay

    Science.gov (United States)

    Onorato, Pasquale; Gratton, Luigi; Malgieri, Massimiliano; Oss, Stefano

    2017-01-01

    The lifetimes of the photoluminescent compounds contained in the coating of fluorescent compact lamps are usually measured using specialised instruments, including pulsed lasers and/or spectrofluorometers. Here we discuss how some low cost apparatuses, based on the use of either sensors for the educational lab or commercial digital photo cameras, can be employed to the same aim. The experiments do not require that luminescent phosphors are hazardously extracted from the compact fluorescent lamp, that also contains mercury. We obtain lifetime measurements for specific fluorescent elements of the bulb coating, in good agreement with the known values. We also address the physical mechanisms on which fluorescence lamps are based in a simplified way, suitable for undergraduate students; and we discuss in detail the physics of the lamp switch-off by analysing the time dependent spectrum, measured through a commercial fiber-optic spectrometer. Since the experiment is not hazardous in any way, requires a simple setup up with instruments which are commonly found in educational labs, and focuses on the typical features of the exponential decay, it is suitable for being performed in the undergraduate laboratory.

  10. 49 CFR 192.623 - Maximum and minimum allowable operating pressure; Low-pressure distribution systems.

    Science.gov (United States)

    2010-10-01

    ... distribution systems. (a) No person may operate a low-pressure distribution system at a pressure high enough to...) No person may operate a low pressure distribution system at a pressure lower than the minimum... 49 Transportation 3 2010-10-01 2010-10-01 false Maximum and minimum allowable operating pressure...

  11. Investigation of low pressure ES-SAGD

    Energy Technology Data Exchange (ETDEWEB)

    Ivory, J.; Zheng, R.; Nasr, T.; Deng, X.; Beaulieu, G.; Heck, G. [Alberta Research Council, Edmonton, AB (Canada)

    2008-10-15

    This paper described a scaled model experiment conducted to investigate the effectiveness of expanding solvent steam assisted gravity drainage (ES-SAGD) processes at low pressures. Lower SAGD pressures typically result in reduced oil production as a result of correspondingly lower steam temperatures. However, lower pressures may also result in a reduced steam to oil ratio (SOR) and a higher vaporization heat. Steam was injected into an injection well at 33 cm{sup 3} per minute and in a production well at 31 cm{sup 3} per minute. Steam and solvents were then co-injected into the injection well at a temperature of 206 degrees C. The experiment was history-matched and a parametric analysis was conducted using a simulation tool. The 2-D and 3-D field-scale simulations investigated the impact of operating pressures, injection rates; sub-cool; oil and gas phase diffusion and dispersion; live oil versus dead oil performance; and the use of drawdown when oil rates declined. Low pressure ES-SAGD was then compared with low-pressure SAGD. Results of the study suggested that production pressures, sub-cool and solvent concentrations are important parameters in ES-SAGD processes. At 1500 kPa production pressure and 10 degrees C sub-cool, the co-injection of solvent with steam increased average oil rates by 15 per cent more than the SAGD process. SOR was also reduced. 6 refs., 8 tabs., 20 figs.

  12. Negative-Pressure Hydrocephalus: A Case Report on Successful Treatment Under Intracranial Pressure Monitoring with Bilateral Ventriculoperitoneal Shunts.

    Science.gov (United States)

    Pandey, Sajan; Jin, Yi; Gao, Liang; Zhou, Cheng Cheng; Cui, Da Ming

    2017-03-01

    Negative-pressure hydrocephalus (NegPH), a very rare condition of unknown etiology and optimal treatment, usually presents postneurosurgery with clinical and imaging features of hydrocephalus, but with negative cerebrospinal fluid pressure. We describe a NegPH case of -3 mm Hg intracranial pressure that was successfully treated to achieve 5 mm Hg under continuous intracranial pressure monitoring with horizontal positioning, head down and legs elevated to 10°-15°, neck wrapping for controlled venous drainage, chest and abdomen bandages, infusion of 5% dextrose fluid to lower plasma osmolarity (Na + , 130-135 mmol/L), daily cerebrospinal fluid drainage >200 mL, and arterial blood gas partial pressure of carbon dioxide >40 mm Hg. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Different systolic blood pressure targets for people with history of stroke or transient ischaemic attack: PAST-BP (Prevention After Stroke—Blood Pressure) randomised controlled trial

    Science.gov (United States)

    McManus, Richard J; Roalfe, Andrea; Fletcher, Kate; Taylor, Clare J; Martin, Una; Virdee, Satnam; Greenfield, Sheila; Hobbs, F D Richard

    2016-01-01

    Objective To assess whether using intensive blood pressure targets leads to lower blood pressure in a community population of people with prevalent cerebrovascular disease. Design Open label randomised controlled trial. Setting 99 general practices in England, with participants recruited in 2009-11. Participants People with a history of stroke or transient ischaemic attack whose systolic blood pressure was 125 mm Hg or above. Interventions Intensive systolic blood pressure target (different target, patients in both arms were actively managed in the same way with regular reviews by the primary care team. Main outcome measure Change in systolic blood pressure between baseline and 12 months. Results 529 patients (mean age 72) were enrolled, 266 to the intensive target arm and 263 to the standard target arm, of whom 379 were included in the primary analysis (182 (68%) intensive arm; 197 (75%) standard arm). 84 patients withdrew from the study during the follow-up period (52 intensive arm; 32 standard arm). Mean systolic blood pressure dropped by 16.1 mm Hg to 127.4 mm Hg in the intensive target arm and by 12.8 mm Hg to 129.4 mm Hg in the standard arm (difference between groups 2.9 (95% confidence interval 0.2 to 5.7) mm Hg; P=0.03). Conclusions Aiming for target below 130 mm Hg rather than 140 mm Hg for systolic blood pressure in people with cerebrovascular disease in primary care led to a small additional reduction in blood pressure. Active management of systolic blood pressure in this population using a blood pressure. Trial registration Current Controlled Trials ISRCTN29062286. PMID:26919870

  14. Photoluminescence from CdxHg1-xTe

    International Nuclear Information System (INIS)

    Breivik, M; Selvig, E; Tonheim, C R; Brendhagen, E; Brudevoll, T; Rheenen, A D van; Steen, H; Nicolas, S; Lorentzen, T; Haakenaasen, R

    2008-01-01

    We present important aspects of photoluminescence (PL) of Cd x Hg 1-x Te in the infrared part of the spectrum where background thermal radiation significantly affects the PL spectrum. We show how the background spectrum can be removed from the data. We also show how the wavelength of the excitation laser affects the relative intensity of the PL peaks from a multi-layer structure. Finally, we present temperature dependent PL of a Cd 0.36 Hg 0.64 Te/Cd 0.61 Hg 0.39 Te multiple quantum well structure grown on a 4 μm thick Cd 0.36 Hg 0.64 Te buffer layer. We attribute the low temperature peak from the buffer layer to impurities. The impurity levels are depopulated as the temperature increases, resulting in a decreased PL peak intensity. Above ∼200 K a band-to-band peak from the buffer layer is observed. The quantum well peak persists up to ∼200 K

  15. Immobilization of Hg(II) by Coprecipitation in Sulfate-Cement Systems

    Science.gov (United States)

    2012-01-01

    Uptake and molecular speciation of dissolved Hg during formation of Al- or Fe-ettringite-type and high-pH phases were investigated in coprecipitation and sorption experiments of sulfate-cement treatments used for soil and sediment remediation. Ettringite and minor gypsum were identified by XRD as primary phases in Al systems, whereas gypsum and ferrihydrite were the main products in Hg–Fe precipitates. Characterization of Hg–Al solids by bulk Hg EXAFS, electron microprobe, and microfocused-XRF mapping indicated coordination of Hg by Cl ligands, multiple Hg and Cl backscattering atoms, and concentration of Hg as small particles. Thermodynamic predictions agreed with experimental observations for bulk phases, but Hg speciation indicated lack of equilibration with the final solution. Results suggest physical encapsulation of Hg as a polynuclear chloromercury(II) salt in ettringite as the primary immobilization mechanism. In Hg–Fe solids, structural characterization indicated Hg coordination by O atoms only and Fe backscattering atoms that is consistent with inner-sphere complexation of Hg(OH)20 coprecipitated with ferrihydrite. Precipitation of ferrihydrite removed Hg from solution, but the resulting solid was sufficiently hydrated to allow equilibration of sorbed Hg species with the aqueous solution. Electron microprobe XRF characterization of sorption samples with low Hg concentration reacted with cement and FeSO4 amendment indicated correlation of Hg and Fe, supporting the interpretation of Hg removal by precipitation of an Fe(III) oxide phase. PMID:22594782

  16. Update on normal tension glaucoma

    Directory of Open Access Journals (Sweden)

    Jyotiranjan Mallick

    2016-01-01

    Full Text Available Normal tension glaucoma (NTG is labelled when typical glaucomatous disc changes, visual field defects and open anterior chamber angles are associated with intraocular pressure (IOP constantly below 21 mmHg. Chronic low vascular perfusion, Raynaud's phenomenon, migraine, nocturnal systemic hypotension and over-treated systemic hypertension are the main causes of normal tension glaucoma. Goldmann applanation tonometry, gonioscopy, slit lamp biomicroscopy, optical coherence tomography and visual field analysis are the main tools of investigation for the diagnosis of NTG. Management follows the same principles of treatment for other chronic glaucomas: To reduce IOP by a substantial amount, sufficient to prevent disabling visual loss. Treatment is generally aimed to lower IOP by 30% from pre-existing levels to 12-14 mmHg. Betaxolol, brimonidine, prostaglandin analogues, trabeculectomy (in refractory cases, systemic calcium channel blockers (such as nifedipine and 24-hour monitoring of blood pressure are considered in the management of NTG. The present review summarises risk factors, causes, pathogenesis, diagnosis and management of NTG.

  17. Long-term low-calorie low-protein vegan diet and endurance exercise are associated with low cardiometabolic risk.

    Science.gov (United States)

    Fontana, Luigi; Meyer, Timothy E; Klein, Samuel; Holloszy, John O

    2007-06-01

    Western diets, which typically contain large amounts of energy-dense processed foods, together with a sedentary lifestyle are associated with increased cardiometabolic risk. We evaluated the long-term effects of consuming a low-calorie low-protein vegan diet or performing regular endurance exercise on cardiometabolic risk factors. In this cross-sectional study, cardiometabolic risk factors were evaluated in 21 sedentary subjects, who had been on a low-calorie low-protein raw vegan diet for 4.4 +/- 2.8 years, (mean age, 53.1 +/- 11 yrs), 21 body mass index (BMI)-matched endurance runners consuming Western diets, and 21 age- and gender-matched sedentary subjects, consuming Western diets. BMI was lower in the low-calorie low-protein vegan diet (21.3 +/- 3.1 kg/m(2)) and endurance runner (21.1 +/- 1.6 kg/m(2)) groups than in the sedentary Western diet group (26.5 +/- 2.7 kg/m(2)) (p vegan diet and runner groups than in the Western diet group (all p vegan diet group (104 +/- 15 and 62 +/- 11 mm Hg) than in BMI-matched endurance runners (122 +/- 13 and 72 +/- 9 mmHg) and Western diet group (132 +/- 14 and 79 +/- 8 mm Hg) (p vegan diet or regular endurance exercise training is associated with low cardiometabolic risk. Moreover, our data suggest that specific components of a low-calorie low-protein vegan diet provide additional beneficial effects on blood pressure.

  18. Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

    Directory of Open Access Journals (Sweden)

    Gonen Baser

    2016-12-01

    Full Text Available Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP, body weights, as well as systolic and diastolic blood pressures (SBP, DBP of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m. in the Ramadan of 2014 and two weeks after it. The data were analyzed using paired Student’s t-test and Pearson correlation analysis. Results: As the results demonstrated, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were 2.67±1.33 mmHg, 9.44±8.02 mmHg, 3.33±5.94 mmHg, and 0.90±0.46 kg during the fasting period, respectively. In addition, the mean diurnal IOP differences of IOP, SBP, DBP, and weight were -0.33±1.4 mmHg (P=0.001, 0.55±7.25mmHg (P=0.003, -3.33±5.94 mmHg (P=0.001, and 0.12±0.45 kg (P=0.001 during the control period, respectively. There was a moderate correlation between the diurnal IOP and SBP differences (r=0.517, P=0.028. Conclusion: Based on the findings of the current study, the total fluid volume might have a more dominant effect on IOP peaks than the sympathetic system activity. Furthermore, the SBP was found to correlate with the IOP.

  19. Valuation of Normal Range of Ankle Systolic Blood Pressure in Subjects with Normal Arm Systolic Blood Pressure.

    Science.gov (United States)

    Gong, Yi; Cao, Kai-wu; Xu, Jin-song; Li, Ju-xiang; Hong, Kui; Cheng, Xiao-shu; Su, Hai

    2015-01-01

    This study aimed to establish a normal range for ankle systolic blood pressure (SBP). A total of 948 subjects who had normal brachial SBP (90-139 mmHg) at investigation were enrolled. Supine BP of four limbs was simultaneously measured using four automatic BP measurement devices. The ankle-arm difference (An-a) on SBP of both sides was calculated. Two methods were used for establishing normal range of ankle SBP: the 99% method was decided on the 99% reference range of actual ankle BP, and the An-a method was the sum of An-a and the low or up limits of normal arm SBP (90-139 mmHg). Whether in the right or left side, the ankle SBP was significantly higher than the arm SBP (right: 137.1 ± 16.9 vs 119.7 ± 11.4 mmHg, P<0.05). Based on the 99% method, the normal range of ankle SBP was 94~181 mmHg for the total population, 84~166 mmHg for the young (18-44 y), 107~176 mmHg for the middle-aged(45-59 y) and 113~179 mmHg for the elderly (≥ 60 y) group. As the An-a on SBP was 13 mmHg in the young group and 20 mmHg in both middle-aged and elderly groups, the normal range of ankle SBP on the An-a method was 103-153 mmHg for young and 110-160 mmHg for middle-elderly subjects. A primary reference for normal ankle SBP was suggested as 100-165 mmHg in the young and 110-170 mmHg in the middle-elderly subjects.

  20. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  1. CALiPER Retail Lamps Study 3.2: Lumen and Chromaticity Maintenance of LED A Lamps Operated in Steady-State Conditions

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-12-31

    This CALiPER report examines lumen depreciation and color shift of 17 different A lamps in steady-state conditions (15 LED, 1 CFL, 1 halogen). The goal of this investigation was to examine the long-term performance of complete LED lamps relative to benchmark halogen and CFL lamps—in this case, A lamps emitting approximately 800 lumens operated continuously at a relatively high ambient temperature of 45°C.

  2. Accumulation of Mercury (Hg) and Methyl Mercury (Me Hg) Concentrations In Selected Marine Biota From Manjung Coastal Area

    International Nuclear Information System (INIS)

    Anisa Abdullah; Zaini Hamzah; Ahmad Saat; Ahmad Saat; Abd Khalik Wood; Masitah Alias

    2015-01-01

    Level of mercury (Hg) and methyl mercury (Me Hg) in marine ecosystem has been intensively studied as these toxic substances could be accumulated in the marine biota. This study is focusing on the Hg and Me Hg content in marine biota in Manjung coastal area. This area has high potential being affected by rapid socio-economic development of Manjung area such as heavy industrial activities (coal fired power plant, iron foundries, port development and factories), agricultural runoff, waste and toxic discharge, quarries, housing constructions. It may has a potential risk when released into the atmosphere and dispersed on the surface of water and continue deposited at the bottom of the water and sediment and being absorbed by marine biota. The concentrations of Hg and Me Hg in marine ecosystem can be adversely affect human health when it enters the food chain. In this study, five species of marine biota including Johnius dussumieri (Ikan Gelama), Pseudorhombus malayanus (Ikan Sebelah), Arius maculatus (Ikan Duri), Portunus pelagicus (Ketam Renjong) and Charybdis natator (Ketam Salib) were collected during rainy and dry seasons. Measurements were carried out using inductively coupled plasma mass spectrometry (ICP-MS) technique. The Hg concentrations for dry and rainy season are in the range 65.13-102.12 μg/ kg and 75.75-106.10 μg/ kg respectively, while for MeHg concentrations for dry and rainy seasons are in the range 4.35-6.26 μg/ kg and 5.42-6.46 μg/ kg, respectively. These results are below the limit set by Malaysia Food Act (1983). Generally, marine biota from the Manjung coastal area is safe to consume due to low value of ingestion dose rate and health risk index (HRI) for human health. (author)

  3. Modeling low pressure baroreceptors and their contribution to blood pressure control

    Directory of Open Access Journals (Sweden)

    Sánchez de Zambrano, Betsy Mirley

    2016-10-01

    Full Text Available The main mechanism for blood pressure (BP control is coordinated by the central nervous system through the sympathetic and parasympathetic systems. In order to simulate this mechanism, different mathematical models are available, but they take into account only the high pressure receptors as sensing systems for BP. However, other receptors located in low pressure areas have not, as far as we know, been considered in the models described in the literature, despite their important role in the nervous BP control. This paper presents a mathematical model for the representation of low pressure receptors by means of the detection of atrial volume changes, and their contribution to immediate BP control through nervous stimulation of the heart rate. The proposed model was coupled to the sensor mechanism of a larger model. With this model it is possible to analyze the contribution and behavior of low pressure receptors, thus allowing a better understanding of this complex system under normal and pathological conditions, since it includes important variables in the immediate BP control, not included in previous models.

  4. [Effects of pressure induced retinal ischemia on ERG in rabbit].

    Science.gov (United States)

    Song, G; Yang, X; Zhang, Z; Zhang, D

    2001-12-01

    To observe the effects of pressure induced retinal ischemia on electroretinogram(ERG) in rabbit. Retinal ischemia was induced in rabbits by increasing intraocular pressure at 30 mmHg, 60 mmHg, 90 mmHg, 120 mmHg for 45 minutes, and retinal function was monitored by eletroretinography. There was no difference on ERG before or after the experiment both in 30 mmHg group and control one. In 60 mmHg pressure induced ischemia eyes, the amplitudes of the b-wave and OPs wave reduced significantly. Four hours after reperfusion, they were totally recovered. After an ischemic insult of 90 mmHg or 120 mmHg for 45 minutes, there was no response of ERG. Four hours later, the amplitudes of the b-wave and OPs wave were 66.912 +/- 20.157 and 16.423 +/- 3.965 the former, 38.852 +/- 23.438 and 8.610 +/- 12.090 the latter, respectively. These results suggest that higher intraocular pressure causes more severe retina ischemic damage, and less recovery ability.

  5. Long-distance transport of Hg, Sb, and As from a mined area, conversion of Hg to methyl-Hg, and uptake of Hg by fish on the Tiber River basin, west-central Italy

    Science.gov (United States)

    Gray, John E.; Rimondi, Valentina; Costagliola, Pilario; Vaselli, Orlando; Lattanzi, Pierfranco

    2014-01-01

    Stream sediment, stream water, and fish were collected from a broad region to evaluate downstream transport and dispersion of mercury (Hg) from inactive mines in the Monte Amiata Hg District (MAMD), Tuscany, Italy. Stream sediment samples ranged in Hg concentration from 20 to 1,900 ng/g, and only 5 of the 17 collected samples exceeded the probable effect concentration for Hg of 1,060 ng/g, above which harmful effects are likely to be observed in sediment-dwelling organisms. Concentrations of methyl-Hg in Tiber River sediment varied from 0.12 to 0.52 ng/g, and although there is no established guideline for sediment methyl-Hg, these concentrations exceeded methyl-Hg in a regional baseline site (water varied from 1.2 to 320 ng/L, all of which were below the 1,000 ng/L Italian drinking water Hg guideline and the 770 ng/L U.S. Environmental Protection Agency (USEPA) guideline recommended to protect against chronic effects to aquatic wildlife. Methyl-Hg concentrations in stream water varied from water samples contained concentrations of As (drinking water guidelines to protect human health (10 μg/L for As and 20 μg/L for Sb) and for protection against chronic effects to aquatic wildlife (150 μg/L for As and 5.6 μg/L for Sb). Concentrations of Hg in freshwater fish muscle ranged from 0.052–0.56 μg/g (wet weight), mean of 0.17 μg/g, but only 17 % (9 of 54) exceeded the 0.30 μg/g (wet weight) USEPA fish muscle guideline recommended to protect human health. Concentrations of Hg in freshwater fish in this region generally decreased with increasing distance from the MAMD, where fish with the highest Hg concentrations were collected more proximal to the MAMD, whereas all fish collected most distal from Hg mines contained Hg below the 0.30 μg/g fish muscle guideline. Data in this study indicate some conversion of inorganic Hg to methyl-Hg and uptake of Hg in fish on the Paglia River, but less methylation of Hg and Hg uptake by freshwater fish in the larger Tiber River.

  6. Positive gain measurements on the 3350-A continuum band of Hg2

    International Nuclear Information System (INIS)

    Schlie, L.A.; Guenther, B.D.; Rathge, R.D.

    1976-01-01

    A He-Cd + laser operating at 3250 A and an Ar + laser at 3511 A and 3638 A have been used to probe for gain on both sides of the Hg 2 3350-A (A 3 1/subu/→X 1 Σ/subg/ + ) continuum band in Hg vapor at a pressure of 3.75 atm that was pumped by a 1.5-MeV 600-J 20-ns electron beam. This letter presents the first observation of positive gain on this 3350-A band of Hg 2 . The results indicate that the stimulated emission cross section for this band is larger than any associated photoionization process in the Hg vapor and has a magnitude of approximately 10 -18 cm 2 . Also, raising the temperature of the vapor above its saturation value increases the maximum value and duration of the observed gain, indicating that the population of the upper level of this transition is being fed by a temperature-dependent internal energy reservoir in the Hg

  7. Slit-lamp photography and videography with high magnifications

    Science.gov (United States)

    Yuan, Jin; Jiang, Hong; Mao, Xinjie; Ke, Bilian; Yan, Wentao; Liu, Che; Cintrón-Colón, Hector R; Perez, Victor L; Wang, Jianhua

    2015-01-01

    Purpose To demonstrate the use of the slit-lamp photography and videography with extremely high magnifications for visualizing structures of the anterior segment of the eye. Methods A Canon 60D digital camera with Movie Crop Function was adapted into a Nikon FS-2 slit-lamp to capture still images and video clips of the structures of the anterior segment of the eye. Images obtained using the slit-lamp were tested for spatial resolution. The cornea of human eyes was imaged with the slit-lamp and the structures were compared with the pictures captured using the ultra-high resolution optical coherence tomography (UHR-OCT). The central thickness of the corneal epithelium and total cornea was obtained using the slit-lamp and the results were compared with the thickness obtained using UHR-OCT. Results High-quality ocular images and higher spatial resolutions were obtained by using the slit-lamp with extremely high magnifications and Movie Crop Function, rather than the traditional slit-lamp. The structures and characteristics of the cornea, such as the normal epithelium, abnormal epithelium of corneal intraepithelial neoplasia, LASIK interface, and contact lenses, were clearly visualized using this device. These features were confirmed by comparing the obtained images with those acquired using UHR-OCT. Moreover, the tear film debris on the ocular surface and the corneal nerve in the anterior corneal stroma were also visualized. The thicknesses of the corneal epithelium and total cornea were similar to that measured using UHR-OCT (P photography and videography with extremely high magnifications allows better visualization of the anterior segment structures of the eye, especially of the epithelium, when compared with the traditional slit-lamp. PMID:26020484

  8. Determination of HID electrode falls in a model lamp I: Pyrometric measurements

    International Nuclear Information System (INIS)

    Dabringhausen, L.; Nandelstaedt, D.; Luhmann, J.; Mentel, J.

    2002-01-01

    To verify models describing the near-electrode regions electrodes of pure and doped tungsten for high intensity discharge lamps are investigated in a special model lamp. It can be operated with arc currents of 1 A to 10 A, DC or AC with arbitrary waveforms up to a few kHz. Argon and xenon, at pressures from 0.1 MPa to 1 MPa, are used as fill gases. A large variety of electrodes can be inserted. To perform spatially resolved measurements they are displaced reproducibly within the discharge tube during lamp operation. Spatially resolved pyrometric measurements of the electrode surface temperature in the case of DC operation are presented. From the temperature distribution the power loss of the electrodes by thermal radiation and heat conduction is determined. It increases almost linearly with the arc current at the anode and less than linear at the cathode. A relation is deduced between the cathode fall and the power fed into the cathode setting up the power balance of the cathodic current transfer zone. The resulting cathode falls show a strong dependence on the electrode diameter. Electrical measurements of separate cathode and anode falls are given in a subsequent paper. The outcomes of both methods and of modelling are compared in a third paper. (author)

  9. Seed disinfection effect of atmospheric pressure plasma and low pressure plasma on Rhizoctonia solani.

    Science.gov (United States)

    Nishioka, Terumi; Takai, Yuichiro; Kawaradani, Mitsuo; Okada, Kiyotsugu; Tanimoto, Hideo; Misawa, Tatsuya; Kusakari, Shinichi

    2014-01-01

    Gas plasma generated and applied under two different systems, atmospheric pressure plasma and low pressure plasma, was used to investigate the inactivation efficacy on the seedborne pathogenic fungus, Rhizoctonia solani, which had been artificially introduced to brassicaceous seeds. Treatment with atmospheric plasma for 10 min markedly reduced the R. solani survival rate from 100% to 3% but delayed seed germination. The low pressure plasma treatment reduced the fungal survival rate from 83% to 1.7% after 10 min and the inactivation effect was dependent on the treatment time. The seed germination rate after treatment with the low pressure plasma was not significantly different from that of untreated seeds. The air temperature around the seeds in the low pressure system was lower than that of the atmospheric system. These results suggested that gas plasma treatment under low pressure could be effective in disinfecting the seeds without damaging them.

  10. Loop-mediated isothermal amplification (LAMP): early detection of Toxoplasma gondii infection in mice.

    Science.gov (United States)

    Kong, Qing-Ming; Lu, Shao-Hong; Tong, Qun-Bo; Lou, Di; Chen, Rui; Zheng, Bin; Kumagai, Takashi; Wen, Li-Yong; Ohta, Nobuo; Zhou, Xiao-Nong

    2012-01-03

    Toxoplasmosis is a widespread zoonotic parasitic disease that occurs in both animals and humans. Traditional molecular assays are often difficult to perform, especially for the early diagnosis of Toxoplasma gondii infections. Here, we established a novel loop-mediated isothermal amplification targeting the 529 bp repeat element (529 bp-LAMP) to detect T. gondii DNA in blood samples of experimental mice infected with tachyzoites of the RH strain. The assay was performed with Bst DNA polymerase at 65°C for 1 h. The detection limit of the 529 bp-LAMP assay was as low as 0.6 fg of T. gondii DNA. The sensitivity of this assay was 100 and 1000 fold higher than that of the LAMP targeting B1 gene (B1-LAMP) and nested PCR targeting 529 bp repeat element (529 bp-nested PCR), respectively. The specificity of the 529 bp-LAMP assay was determined using the DNA samples of Trypanosoma evansi, Plasmodium falciparum, Paragonimus westermani, Schistosoma japonicum, Fasciola hepatica and Angiostrongylus cantonensis. No cross-reactivity with the DNA of any parasites was found. The assay was able to detect T. gondii DNA in all mouse blood samples at one day post infection (dpi). We report the following findings: (i) The detection limit of the 529 bp-LAMP assay is 0.6 fg of T. gondii DNA; (ii) The assay does not involve any cross-reactivity with the DNA of other parasites; (iii) This is the first report on the application of the LAMP assay for early diagnosis of toxoplasmosis in blood samples from experimentally infected mice. Due to its simplicity, sensitivity and cost-effectiveness for common use, we suggest that this assay should be used as an early diagnostic tool for health control of toxoplasmosis.

  11. The Effects of Lamp Spectral Distribution on Sky Glow over Observatories

    Science.gov (United States)

    2015-01-01

    overhead sky glow as a function of distance up to 300 km, from a variety of lamp types, including common gas discharge lamps and several types of LED...distance up to 300 km, from a variety of lamp types, in- cluding common gas discharge lamps and several types of LED lamps . We conclude for both...MAR 2015 2. REPORT TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE The Effects of Lamp Spectral Distribution on Sky Glow

  12. Home readings of blood pressure in assessment of hypertensive subjects

    DEFF Research Database (Denmark)

    Nielsen, P.E.; Myschetzky, P; Andersen, A R

    1986-01-01

    Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self......-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter...

  13. On the potential of Hg-Photo-CVD process for the low temperature growth of nano-crystalline silicon (Topical review)

    International Nuclear Information System (INIS)

    Barhdadi, A.

    2005-08-01

    Mercury-Sensitized Photo-Assisted Chemical Vapor Deposition (Hg-Photo-CVD) technique opens new possibilities for reducing thin film growth temperature and producing novel semiconductor materials suitable for the future generation of high efficiency thin film solar cells onto low cost flexible plastic substrates. This paper provides an overview of this technique, with the emphasis on its potential in low temperature elaboration of nano-crystalline silicon for the development of thin films photovoltaic technology. (author)

  14. Extended x-ray absorption fine structure study of arsenic in HgCdTe: p-type doping linked to nonsubstitutional As incorporation in an unknown AsHg8 structure

    International Nuclear Information System (INIS)

    Biquard, X.; Alliot, I.; Ballet, P.

    2009-01-01

    An extended x-ray absorption fine structure (EXAFS) investigation has been carried out on arsenic-doped Hg 70 Cd 30 Te samples. The incorporation of atomic arsenic has been achieved using a nonconventional radio-frequency plasma source in a molecular beam epitaxy reactor. Two samples from the same epitaxial wafer have been studied. One underwent a 400 deg. C activation annealing under Hg pressure, leading to n to p-type conversion. In the commonly admitted scenario, this conversion is associated with the annealing-induced migration of As from a Hg site to a Te site. This study shows that this is not the case. Before annealing, As is found to be involved in noncrystalline structures: 50% inside an As 2 Te 3 chalcogenide glass and 50% inside a new AsHg 8 compact structure. After annealing, the As 2 Te 3 chalcogenide glass disappears, 31% of As occupies Hg sites and 69% incorporates inside this new AsHg 8 compact structure that occupies Te sites. The EXAFS results are in excellent agreement with 77 K Hall-effect measurements. The new AsHg 8 structure is found to have an acceptor behavior. Overall, this study provides an entirely new vision of extrinsic p-type doping of HgCdTe as well as the first experimental evidence of As site transfer induced by annealing.

  15. Emission and absorption spectroscopy study of Ar excited states in 13.56 MHz argon plasma operating at sub-atmospheric to atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Li, L. [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium); Nikiforov, A., E-mail: anton.nikiforov@ugent.be [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium); Institute of Solution Chemistry of the Russian Academy of Science, Academicheskaya St., 1, Ivanovo, 153045 (Russian Federation); Britun, N. [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Universite de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Snyders, R. [Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Universite de Mons, 23 Place du Parc, B-7000 Mons (Belgium); Materia Nova Research Centre, Parc Initialis, B-7000 Mons (Belgium); Leys, C. [Department of Applied Physics, Research Unit Plasma Technology, Ghent University, Jozef Plateaustraat 22, Ghent B-9000 (Belgium)

    2015-05-01

    The densities of metastable and resonant states of Ar atoms are measured in high pressure Ar radio frequency discharge. Resonant absorption spectroscopy for the case of a low pressure spectral lamp and high-pressure plasma absorption lines is implemented for this purpose. The necessary generalizations for the high-pressure resonant absorption method are given. Absolute density of Ar 1s levels obtained at different RF input power and operating pressures are of the order of 10{sup 11} cm{sup −3}, which is in a good agreement with those reported in the literature. The population distribution on the Ar 2p (excited) levels, obtained from the optical emission spectroscopy, reveals strong deviation from thermal equilibrium for these levels in the high-pressure case. The generation of the Ar excited states in the studied discharges is compared to the previously reported results. - Highlights: • Strong non-equilibrium distribution of Ar 2p levels is observed. • The absolute number density of non-radiative Ar 1s states is determined by the easier and low cost spectral-lamp absorption method. • The modified absorption theory of Mitchell and Zemanski was used to obtain the absolute number density of Ar 1s states at high pressure. • The developed RF source with 5 cm long gap can be a possible alternative to micro-plasma working in Ar at atmospheric pressure.

  16. Benchtop evaluation of pressure barrier insufflator and standard insufflator systems.

    Science.gov (United States)

    Nepple, Kenneth G; Kallogjeri, Dorina; Bhayani, Sam B

    2013-01-01

    Previous experimental research has reported minimal differences in pressure maintenance between different versions of standard insufflators (SI). However, a recent report identified potential clinical benefits with a valveless pressure barrier insufflator (PBI). We sought to perform a benchtop objective evaluation of SI and PBI systems. A rigid box system with continuous pressure manometry was used to evaluate a PBI (Surgiquest Airseal) and two SIs (SI1 = Stryker PneumoSure High Flow Insufflator and SI2 = Storz SCB Thermoflator). Pressure maintenance of 15 mmHg was evaluated during experimental conditions of leakage from a 5 mm port site, leakage from a 12 mm port site, and continuous suction. With leakage from the 5 mm port site, the PBI maintained pressure of >13 mmHg whereas the pressures dropped moderately with the SI1 (7-13 mmHg) and SI2 insufflators (3-7 mmHg) and did not regain goal pressure until leakage was stopped. With leakage from 12 mm port site, the PBI pressure decreased to 9-11 mmHg, whereas the SI1 and SI2 lost insufflation pressures completely. The PBI maintained pressure of >11 mmHg during continuous suction while the SI1 and SI2 lost pressure entirely, and actually showed negative pressure from air suction into the rigid box system. When evaluated statistically with the mixed model repeated measures ANOVA, the SI1 and SI2 performed similarly while the PBI maintained increased pressure. In the experimental rigid box system, the PBI more successfully maintained pressure in response to leakage and suction than SIs.

  17. Recurrent symptomatic intraocular pressure spikes during hemodialysis in a patient with unilateral anterior uveitis

    Directory of Open Access Journals (Sweden)

    Lim Su-Ho

    2013-02-01

    Full Text Available Abstract Background The relationship between intraocular pressure (IOP changes and hemodialysis has been evaluated for several decades. However, no report on an IOP rise in uveitis patients during hemodialysis has been previously documented. This report describes the case of an uveitis patient with repetitive IOP spikes associated with severe ocular pain during hemodialysis sessions, which resolved after glaucoma filtering surgery. Case presentation A 47-year-old male with diabetes and hypertension had complained of recurrent ocular pain in the left eye during hemodialysis sessions. A slit-lamp examination showed diffuse corneal epithelial edema with several white keratic precipitates and inflammatory cells (Grade 3+ in the anterior chamber of the left eye. No visible neovascularization or synechiae were visible on the iris or angle. Topical glaucoma eye-drops and intravenous mannitol before hemodialysis did not prevent subsequent painful IOP spikes in the left eye. At the end of hemodialysis, IOP averaged ~40 mmHg. After trabeculectomy with mitomycin C in the left eye, his IOP stabilized in the low-teens (range, 10–14 mmHg and no painful IOP spikes occurred during hemodialysis over the first postoperative year. Conclusion We present a case of recurrent painful IOP spikes during hemodialysis in a patient with unilateral anterior uveitis unresponsive to conventional medical treatment prior to hemodialysis. To our knowledge, this is the first case report of repetitive symptomatic IOP rise during hemodialysis in an uveitic glaucoma patient. This case highlights the importance of the awareness of the possibility that IOP may rise intolerably during hemodialysis in uveitis patients with a compromised outflow facility.

  18. Nanocomposite-Based Microstructured Piezoresistive Pressure Sensors for Low-Pressure Measurement Range

    Directory of Open Access Journals (Sweden)

    Vasileios Mitrakos

    2018-01-01

    Full Text Available Piezoresistive pressure sensors capable of detecting ranges of low compressive stresses have been successfully fabricated and characterised. The 5.5 × 5 × 1.6 mm3 sensors consist of a planar aluminium top electrode and a microstructured bottom electrode containing a two-by-two array of truncated pyramids with a piezoresistive composite layer sandwiched in-between. The responses of two different piezocomposite materials, a Multiwalled Carbon Nanotube (MWCNT-elastomer composite and a Quantum Tunneling Composite (QTC, have been characterised as a function of applied pressure and effective contact area. The MWCNT piezoresistive composite-based sensor was able to detect pressures as low as 200 kPa. The QTC-based sensor was capable of detecting pressures as low as 50 kPa depending on the contact area of the bottom electrode. Such sensors could find useful applications requiring the detection of small compressive loads such as those encountered in haptic sensing or robotics.

  19. RESTING SYMPATHETIC BAROREFLEX SENSITIVITY IN SUBJECTS WITH LOW AND HIGH TOLERANCE TO CENTRAL HYPOVOLEMIA INDUCED BY LOWER BODY NEGATIVE PRESSURE

    Directory of Open Access Journals (Sweden)

    Carmen eHinojosa-Laborde

    2014-06-01

    Full Text Available Central hypovolemia elicited by orthostasis or hemorrhage triggers sympathetically-mediated baroreflex responses to maintain organ perfusion; these reflexes are less sensitive in patients with orthostatic intolerance, and during conditions of severe blood loss, may result in cardiovascular collapse (decompensatory or circulatory shock. The ability to tolerate central hypovolemia is variable and physiological factors contributing to tolerance are emerging. We tested the hypothesis that resting muscle sympathetic nerve activity (MSNA and sympathetic baroreflex sensitivity (BRS are attenuated in male and female subjects who have low tolerance (LT to central hypovolemia induced by lower body negative pressure (LBNP. MSNA and diastolic arterial pressure (DAP were recorded in 47 human subjects who subsequently underwent LBNP to tolerance (onset of presyncopal symptoms. LT subjects experienced presyncopal symptoms prior to completing LBNP of -60 mm Hg, and subjects with high tolerance (HT experienced presyncopal symptoms after completing LBNP after -60 mmHg. Contrary to our hypothesis, resting MSNA burst incidence was not different between LT and HT subjects, and was not related to time to presyncope. BRS was assessed as the slope of the relationship between spontaneous fluctuations in DAP and MSNA during 5 min of supine rest. MSNA burst incidence/DAP correlations were greater than or equal to 0.5 in 37 subjects (LT: n= 9; HT: n=28, and BRS was not different between LT and HT (-1.8 ± 0.3 vs. -2.2 ± 0.2 bursts•(100 beats-1•mmHg-1, p=0.29. We conclude that tolerance to central hypovolemia is not related to either resting MSNA or sympathetic BRS.

  20. LIF-measurements on a low prassure RF-driven InBr lamp

    NARCIS (Netherlands)

    Mulders, H.C.J.; Stoffels, W.W.

    2007-01-01

    A laser induced fluorescence (LIF) experiment has been carried out on a low pressure, capacitively coupled RF driven. Ar discharge with InBr as an additive. The intention is to find the density of the different states of InBr and the metastable states in particular. We measured the density profile

  1. Acute retinal ischemia caused by controlled low ocular perfusion pressure in a porcine model. Electrophysiological and histological characterisation

    DEFF Research Database (Denmark)

    Kyhn, Maria Voss; Warfvinge, Karin; Scherfig, Erik

    2009-01-01

    The purpose of this study was to establish, and characterize a porcine model of acute, controlled retinal ischemia. The controlled retinal ischemia was produced by clamping the ocular perfusion pressure (OPP) in the left eye to 5 mm Hg for 2 h. The OPP was defined as mean arterial blood pressure...... of the amplitudes obtained in the experimental, left eye, and the control, right eye. Quantitative histology was performed to measure the survival of ganglion cells, amacrine cells and horizontal cells 2-6 weeks after the ischemic insult. An OPP of 5 mm Hg for 2h induced significant reductions in the amplitudes...... the ischemic insult. This model seems to be suitable for investigations of therapeutic initiatives in diseases involving acute retinal ischemia....

  2. Light and Light Sources High-Intensity Discharge Lamps

    CERN Document Server

    Flesch, Peter G

    2006-01-01

    Light and Light Sources gives an introduction to the working principles of high-intensity discharge (HID) lamps and points out challenges and problems associated with the development and operation of HID lamps. The state-of-the-art in electrode and plasma diagnostics as well as numerical methods used for the understanding of HID lamps are described. This volume addresses students as well as scientists and researchers at universities and in industry.

  3. A Pulse Wave Velocity Based Method to Assess the Mean Arterial Blood Pressure Limits of Autoregulation in Peripheral Arteries

    Directory of Open Access Journals (Sweden)

    Ananya Tripathi

    2017-11-01

    Full Text Available Background: Constant blood flow despite changes in blood pressure, a phenomenon called autoregulation, has been demonstrated for various organ systems. We hypothesized that by changing hydrostatic pressures in peripheral arteries, we can establish these limits of autoregulation in peripheral arteries based on local pulse wave velocity (PWV.Methods: Electrocardiogram and plethysmograph waveforms were recorded at the left and right index fingers in 18 healthy volunteers. Each subject changed their left arm position, keeping the right arm stationary. Pulse arrival times (PAT at both fingers were measured and used to calculate PWV. We calculated ΔPAT (ΔPWV, the differences between the left and right PATs (PWVs, and compared them to the respective calculated blood pressure at the left index fingertip to derive the limits of autoregulation.Results: ΔPAT decreased and ΔPWV increased exponentially at low blood pressures in the fingertip up to a blood pressure of 70 mmHg, after which changes in ΔPAT and ΔPWV were minimal. The empirically chosen 20 mmHg window (75–95 mmHg was confirmed to be within the autoregulatory limit (slope = 0.097, p = 0.56. ΔPAT and ΔPWV within a 20 mmHg moving window were not significantly different from the respective data points within the control 75–95 mmHg window when the pressure at the fingertip was between 56 and 110 mmHg for ΔPAT and between 57 and 112 mmHg for ΔPWV.Conclusions: Changes in hydrostatic pressure due to changes in arm position significantly affect peripheral arterial stiffness as assessed by ΔPAT and ΔPWV, allowing us to estimate peripheral autoregulation limits based on PWV.

  4. Role of autonomic nervous activity, as measured by heart rate variability, on the effect of mortality in disabled older adults with low blood pressure in long-term care.

    Science.gov (United States)

    Shibasaki, Koji; Ogawa, Sumito; Yamada, Shizuru; Ouchi, Yasuyoshi; Akishita, Masahiro

    2018-04-11

    Previous studies have shown the relationship between low blood pressure and high mortality in frail, disabled older adults in long-term care. However, the mechanism of this relationship is still unclear. We hypothesized that autonomic nervous activity decline is involved in the relationship between low blood pressure and high mortality. The present prospective cohort study recruited 61 participants aged ≥75 years. The data from 24-h Holter monitoring and blood pressure recorded by ambulatory blood pressure monitoring were collected. Measured data were divided into three categories: 24-h, daytime and night-time. From power spectral density in the electrocardiogram, low frequency, high frequency and low frequency/high frequency ratio were calculated. The primary end-point was death. High blood pressure was connected to both high daytime low frequency and high frequency (partial correlation coefficients: 0.42, P blood pressure group had higher mortality than the high blood pressure group, and disabled older adults in long-term care and those with elevated daytime systolic and diastolic blood pressure had less risk of mortality compared with those without (systolic: hazard ratio 0.89, 95% confidence interval 0.83-0.96, P = 0.003; diastolic: hazard ratio 0.98, 95% confidence interval 0.79-1.00, P = 0.049). The average blood pressures in the high blood pressure groups were approximately 140/80 mmHg and were connected to low mortality. Attenuated autonomic nervous activity might lead to low blood pressure in the daytime and high mortality in disabled older adults in long-term care. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 Japan Geriatrics Society.

  5. The Role of Molecules in Low Temperature Plasmas for Lighting

    International Nuclear Information System (INIS)

    Lapatovich, Walter P.

    2007-01-01

    High intensity discharge (HID) lamps are low temperature (∼0.5eV), weakly ionized plasmas sustained in a refractory but light transmissive envelope for the purpose of converting electrical power into visible radiation. For commercial applications this conversion must occur with good efficiency and with sufficient spectral content throughout the visible (380-780nm) to permit the light so generated to render colors in a fashion comparable to natural sunlight. These goals are often achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, chemical compounds containing the desired metals, and having higher vapor pressures are used to introduce the material into the basic discharge. Complexing agents which further improve the vapor pressure are used to enhance the amount of metals in the discharge. The metal compound and complexes are usually polyatomic species which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Under the approximation of local thermodynamic equilibrium (LTE) the particles are in equilibrium, but not with the radiation Held. Strong thermal (106K/m) and density gradients are sustained in the discharge. Atomic and molecular radiation produced in the high temperature core transits through colder gas regions before exiting the lamp. In these regions where the complex molecular species exists in an undissociated state, bound-free transitions can result in energy being effectively converted from light radiation into heat in the mantle. Bound-bound transitions In Identifiable molecules can result in modification of the spectral output in unpredictable and counter-intuitive ways. Examples of completing agents and their effect on the spectral output of typical rare-earth containing HID lamps will be given. The melt composition and the complexing agents themselves may change with time, as chemical reactions in the lamp occur, and their benefit

  6. Electrodeless discharge lamp is easily started, has high stability

    Science.gov (United States)

    Bell, W. E.; Bloom, A. L.

    1966-01-01

    Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

  7. Continuous positive airway pressure reduces blood pressure in patients with obstructive sleep apnea; a systematic review and meta-analysis with 1000 patients.

    Science.gov (United States)

    Schein, Andressa S O; Kerkhoff, Alessandra C; Coronel, Christian C; Plentz, Rodrigo D M; Sbruzzi, Graciele

    2014-09-01

    Obstructive sleep apnea (OSA) may lead to the development of hypertension and therapy with continuous positive airway pressure (CPAP) can promote reduction in blood pressure. The objective of this study is to review systematically the effects of CPAP on blood pressure in patients with OSA. The search was conducted in the following databases, from their beginning until February 2013: MEDLINE, Embase, Cochrane CENTRAL, Lilacs and PEDro. In addition, a manual search was performed on references of published studies. Randomized clinical trials (RCTs) that used CPAP compared with placebo CPAP or subtherapeutic CPAP for treatment of patients with OSA and that evaluated office SBP and DBP and 24-h ambulatory blood pressure were selected. Sixteen RCTs were included among 3409 publications, totaling 1166 patients. The use of CPAP resulted in reductions in office SBP [-3.20  mmHg; 95% confidence interval (CI) -4.67 to -1.72] and DBP (-2.87  mmHg; 95% CI -5.18 to -0.55); in night-time SBP (-4.92  mmHg; 95% CI -8.70 to -1.14); in mean 24-h blood pressure (-3.56  mmHg; 95% CI -6.79 to -0.33), mean night-time blood pressure (-2.56  mmHg; 95% CI -4.43 to -0.68) and 24-h DBP (-3.46  mmHg; 95% CI -6.75 to -0.17). However, no significant change was observed in daytime SBP (-0.74  mmHg; 95% CI -3.90 to 2.41) and daytime DBP (-1.86  mmHg; 95% CI -4.55 to 0.83). Treatment with CPAP promoted significantly but small reductions in blood pressure in individuals with OSA. Further studies should be performed to evaluate the effects of long-term CPAP and the impact on cardiovascular risk.

  8. Three dimensional numerical study of different parameters effect on the external magnetic field applied to center the arc of the horizontal mercury discharge lamp

    Directory of Open Access Journals (Sweden)

    Mohamed Bechir Ben Hamida

    2015-10-01

    Full Text Available The aim of this paper is to evaluate the magnitude of the external magnetic field to be applied to a horizontal mercury discharge lamp such that the Lorentz forces counterbalance buoyancy forces and the hot region of the arc remains centered inside the lamp with the variation of six parameters of the lamp such as the external temperature of the lamp, envelope thickness, convective loss, Interelectrodeslength, pressure and current supply pointing to the influence of the parameters to the compensating magnetic field value. To achieve this objective, a commercial numerical software “Comsol Multiphysics” is used to implement the model that solves the equations of mass, energy and momentum for laminar compressible flow combined with the Laplace equation for the plasma in a three dimensional.

  9. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  10. LED lamp power management system and method

    Science.gov (United States)

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

    2013-03-19

    An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

  11. Permissive hypotension in the extremely low birthweight infant with signs of good perfusion.

    LENUS (Irish Health Repository)

    Dempsey, E M

    2012-01-31

    INTRODUCTION: Many practitioners routinely treat infants whose mean arterial blood pressure in mm Hg is less than their gestational age in weeks (GA). OBJECTIVE: To assess the effectiveness of utilising a combined approach of clinical signs, metabolic acidosis and absolute blood pressure (BP) values when deciding to treat hypotension in the extremely low birthweight (ELBW) infant. METHODS: Retrospective cohort study of all live born ELBW infants admitted to our neonatal intensive care unit over a 4-year period. Patients were grouped as either normotensive (BP never less than GA), hypotensive and not treated (BPpressure data were available on 108 patients. 53% of patients were hypotensive (mean BP in mm Hg less than GA in weeks). Treated patients had lower birth weight and GA, and significantly lower blood pressure at 6, 12, 18 and 24 h. Normotensive patients and patients designated as having permissive hypotension had similar outcomes. Mean blood pressure in the permissive group increased from 26 mm Hg at 6 h to 31 mm Hg at 24 h. In a logistic regression model, treated hypotension is independently associated with mortality, odds ratio 8.0 (95% CI 2.3 to 28, p<0.001). CONCLUSIONS: Blood pressure spontaneously improves in ELBW infants during the first 24 h. Infants hypotensive on GA criteria but with clinical evidence of good perfusion had as good an outcome as normotensive patients. Treated low blood pressure was associated with adverse outcome.

  12. Simulation of low pressure water hammer

    Science.gov (United States)

    Himr, D.; Habán, V.

    2010-08-01

    Numerical solution of water hammer is presented in this paper. The contribution is focused on water hammer in the area of low pressure, which is completely different than high pressure case. Little volume of air and influence of the pipe are assumed in water, which cause sound speed change due to pressure alterations. Computation is compared with experimental measurement.

  13. A Neutron Scattering Study of Lattice Dynamics of HgTe and HgSe

    DEFF Research Database (Denmark)

    Kepa, H.; Giebultowicz, T.; Buras, B.

    1982-01-01

    The dispersion relations for the acoustic and optic phonons in HgTe and for the acoustic phonons in HgSe were determined by neutron inelastic scattering in three high symmetry directions. The effect of the free-carrier screening of the long-range electric field of LO phonons in HgTe was observed....... The formalism of the rigid ion model is used for numerical calculations of the phonon dispersion relations and the phonon densities of states in HgTe and HgSe....

  14. Microbial Oxidation of Hg(0) - Its Effect on Hg Stable Isotope Fractionation and Methylmercury Production

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Nathan [Rutgers Univ., New Brunswick, NJ (United States); Barkay, Tamar [Rutgers Univ., New Brunswick, NJ (United States); Reinfelder, John [Rutgers Univ., New Brunswick, NJ (United States)

    2016-06-28

    Mercury (Hg) associated with mixed waste generated by nuclear weapons manufacturing has contaminated vast areas of the Oak Ridge Reservation (ORR). Neurotoxic methylmercury (MeHg) has been formed from the inorganic Hg wastes discharged into headwaters of East Fork Poplar Creek (EFPC). Thus, understanding the processes and mechanisms that lead to Hg methylation along the flow path of EFPC is critical to predicting the impacts of the contamination and the design of remedial action at the ORR. In part I of our project, we investigated Hg(0) oxidation and methylation by anaerobic bacteria. We discovered that the anaerobic bacterium Desulfovibrio desulfuricans ND132 can oxidize elemental mercury [Hg(0)]. When provided with dissolved elemental mercury, D. desulfuricans ND132 converts Hg(0) to Hg(II) and neurotoxic methylmercury [MeHg]. We also demonstrated that diverse species of subsurface bacteria oxidizes dissolved elemental mercury under anoxic conditions. The obligate anaerobic bacterium Geothrix fermentans H5, and the facultative anaerobic bacteria Shewanella oneidensis MR-1 and Cupriavidus metallidurans AE104 can oxidize Hg(0) to Hg(II) under anaerobic conditions. In part II of our project, we established anaerobic enrichment cultures and obtained new bacterial strains from the DOE Oak Ridge site. We isolated three new bacterial strains from subsurface sediments collected from Oak Ridge. These isolates are Bradyrhizobium sp. strain FRC01, Clostridium sp. strain FGH, and a novel Negativicutes strain RU4. Strain RU4 is a completely new genus and species of bacteria. We also demonstrated that syntrophic interactions between fermentative bacteria and sulfate-reducing bacteria in Oak Ridge saprolite mediate iron reduction via multiple mechanisms. Finally, we tested the impact of Hg on denitrification in nitrate reducing enrichment cultures derived from subsurface sediments from the Oak Ridge site, where nitrate is a major contaminant. We showed that there is an inverse

  15. Hg(II) removal from aqueous solutions by bacillus subtilis biomass

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xue Song; Li, Fei Yan; He, Wen; Miao, Hua Hua [Department of Chemical Engineering, Huaihai Institute of Technology, Lianyungang (China)

    2010-01-15

    The biosorption of Hg(II) from aqueous solutions using Bacillus subtilis biomass was investigated in this study. The adsorbent was characterized by FTIR. Various factors including solution pH, initial concentration of Hg(II), contact time, reaction temperature and ionic strength were taken into account and promising results were obtained. An initial solution pH of 5.0 was most favorable for Hg(II) removal. The kinetic data was also analyzed using pseudo first order and pseudo second order equations. The results suggested that Hg(II) bioadsorption was best represented by the pseudo second order equation. Freundlich, Langmuir and Langmuir-Freundlich isotherms for the present systems were analyzed. The most satisfactory interpretation for the equilibrium data at different temperatures was given by the Langmuir-Freundlich isotherm. The effect of ionic strength on bioadsorption was significant. Bacillus subtilis biomass could serve as low cost adsorbent to remove Hg(II) from aqueous solutions, especially at lower concentrations of Hg(II) (<20 mg Hg/L). (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  16. Tracing historical trends of Hg in the Mississippi River using Hg concentrations and Hg isotopic compositions in a lake sediment core, Lake Whittington, Mississippi, USA

    Science.gov (United States)

    Gray, John E.; Van Metre, Peter C.; Pribil, Michael J.; Horowitz, Arthur J.

    2015-01-01

    Concentrations and isotopic compositions of mercury (Hg) in a sediment core collected from Lake Whittington, an oxbow lake on the Lower Mississippi River, were used to evaluate historical sources of Hg in the Mississippi River basin. Sediment Hg concentrations in the Lake Whittington core have a large 10-15 y peak centered on the 1960s, with a maximum enrichment factor relative to Hg in the core of 4.8 in 1966. The Hg concentration profile indicates a different Hg source history than seen in most historical reconstructions of Hg loading. The timing of the peak is consistent with large releases of Hg from Oak Ridge National Laboratory (ORNL), primarily in the late 1950s and 1960s. Mercury was used in a lithiumisotope separation process by ORNL and an estimated 128Mg (megagrams) of Hgwas discharged to a local stream that flows into the Tennessee River and, eventually, the Mississippi River. Mass balance analyses of Hg concentrations and isotopic compositions in the Lake Whittington core fit a binary mixing model with a Hg-rich upstream source contributing about 70% of the Hg to Lake Whittington at the height of the Hg peak in 1966. This upstream Hg source is isotopically similar to Hg isotope compositions of stream sediment collected downstream near ORNL. It is estimated that about one-half of the Hg released from the ORNL potentially reached the LowerMississippi River basin in the 1960s, suggesting considerable downstream transport of Hg. It is also possible that upstream urban and industrial sources contributed some proportion of Hg to Lake Whittington in the 1960s and 1970s.

  17. Effects of parental smoking on exercise systolic blood pressure in adolescents.

    Science.gov (United States)

    Hacke, Claudia; Weisser, Burkhard

    2015-05-11

    In adults, exercise blood pressure seems to be more closely related to cardiovascular risk than resting blood pressure; however, few data are available on the effects of familial risk factors, including smoking habits, on exercise blood pressure in adolescents. Blood pressure at rest and during exercise, parental smoking, and other familial risk factors were investigated in 532 adolescents aged 12 to 17 years (14.6±1.5 years) in the Kiel EX.PRESS. (EXercise PRESSure) Study. Exercise blood pressure was determined at 1.5 W/kg body weight using a standardized submaximal cycle ergometer test. Mean resting blood pressure was 113.1±12.8/57.2±7.1 mm Hg, and exercise blood pressure was 149.9±19.8/54.2±8.6 mm Hg. Parental smoking increased exercise systolic blood pressure (+4.0 mm Hg, 3.1 to 4.9; P=0.03) but not resting blood pressure of the subjects (adjusted for age, sex, height, body mass index percentile, fitness). Parental overweight and familial hypertension were related to both higher resting and exercise systolic blood pressure values, whereas associations with an inactive lifestyle and a low educational level of the parents were found only with adolescents' blood pressure during exercise. The cumulative effect of familial risk factors on exercise systolic blood pressure was more pronounced than on blood pressure at rest. Parental smoking might be a novel risk factor for higher blood pressure, especially during exercise. In addition, systolic blood pressure during a submaximal exercise test was more closely associated with familial risk factors than was resting blood pressure, even in adolescents. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. 10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.

    Science.gov (United States)

    2010-01-01

    ... high intensity discharge fixture, the efficiency of a lamp and ballast combination, expressed as a... lamps. Metal halide lamp means a high intensity discharge lamp in which the major portion of the light... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning metal halide lamp ballasts and...

  19. Performance and application of controlled temperature-gradient lamps in atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Gough, D.S.; Sullivan, J.V.

    1981-01-01

    An improved design of controlled temperature-gradient lamp (CTGL) is suitable for arsenic, cadmium, phosphorus, potassium, rubidium, selenium, sodium, sulphur and zinc. Intensity and linewidth measurements indicate that the CTGL is significantly more intense than an electrodeless discharge lamp (EDL) at the same linewidth. CTGL's also compare favourably with EDL's when used as light sources for a.a.s. Arsenic and selenium can be determined at very low concentrations (ng ml -1 ) by the hydride generation technique. Sulphur and phosphorus can be detected in the vacuum ultra-violet region using nitrogen-separated flames; the limits of detection are 13 and 10 μg ml -1 , respectively. (Auth.)

  20. Infusion pressure and pain during microneedle injection into skin of human subjects

    Science.gov (United States)

    Gupta, Jyoti; Park, Sohyun; Bondy, Brian; Felner, Eric I.; Prausnitz, Mark R.

    2011-01-01

    Infusion into skin using hollow microneedles offers an attractive alternative to hypodermic needle injections. However, the fluid mechanics and pain associated with injection into skin using a microneedle have not been studied in detail before. Here, we report on the effect of microneedle insertion depth into skin, partial needle retraction, fluid infusion flow rate and the co-administration of hyaluronidase on infusion pressure during microneedle-based saline infusion, as well as on associated pain in human subjects. Infusion of up to a few hundred microliters of fluid required pressures of a few hundred mmHg, caused little to no pain, and showed weak dependence on infusion parameters. Infusion of larger volumes up to 1 mL required pressures up to a few thousand mmHg, but still usually caused little pain. In general, injection of larger volumes of fluid required larger pressures and application of larger pressures cause more pain, although other experimental parameters also played a significant role. Among the intradermal microneedle groups, microneedle length had little effect; microneedle retraction lowered infusion pressure but increased pain; lower flow rate reduced infusion pressure and kept pain low; and use of hyaluronidase also lowered infusion pressure and kept pain low. We conclude that microneedles offer a simple method to infuse fluid into the skin that can be carried out with little to no pain. PMID:21684001

  1. Shock tubes: compressions in the low pressure chamber

    International Nuclear Information System (INIS)

    Schins, H.; Giuliani, S.

    1986-01-01

    The gas shock tube used in these experiments consists of a low pressure chamber and a high pressure chamber, divided by a metal-diaphragm-to-rupture. In contrast to the shock mode of operation, where incident and reflected shocks in the low pressure chamber are studied which occur within 3.5 ms, in this work the compression mode of operation was studied, whose maxima occur (in the low pressure chamber) about 9 ms after rupture. Theoretical analysis was done with the finite element computer code EURDYN-1M, where the computation was carried out to 30 ms

  2. Low pressure lithium condensation

    International Nuclear Information System (INIS)

    Wadkins, R.P.; Oh, C.H.

    1985-01-01

    A low pressure experiment to evaluate the laminar film condensation coefficients of lithium was conducted. Some thirty-six different heat transfer tests were made at system pressures ranging from 1.3 to 26 Pa. Boiled lithium was condensed on the inside of a 7.6-cm (ID), 409 stainless-steel pipe. Condensed lithium was allowed to reflux back to the pool boiling region below the condensing section. Fourteen chromel/alumel thermocouples were attached in various regions of the condensing section. The thermocouples were initially calibrated with errors of less than one degree Celsius

  3. Stability of very-high pressure arc discharges against perturbations of the electron temperature

    Energy Technology Data Exchange (ETDEWEB)

    Benilov, M. S. [Departamento de Fisica, Ciencias Exactas e Engenharia, Universidade da Madeira, Largo do Municipio, Funchal 9000 (Portugal); Hechtfischer, U. [Philips Lighting, BU Automotive Lamps, Technology, Philipsstrasse 8, Aachen 52068 (Germany)

    2012-04-01

    We study the stability of the energy balance of the electron gas in very high-pressure plasmas against longitudinal perturbations, using a local dispersion analysis. After deriving a dispersion equation, we apply the model to a very high-pressure (100 bar) xenon plasma and find instability for electron temperatures, T{sub e}, in a window between 2400 K and 5500-7000 K x 10{sup 3} K, depending on the current density (10{sup 6}-10{sup 8} A/m{sup 2}). The instability can be traced back to the Joule heating of the electron gas being a growing function of T{sub e}, which is due to a rising dependence of the electron-atom collision frequency on T{sub e}. We then analyze the T{sub e} range occurring in very high-pressure xenon lamps and conclude that only the near-anode region exhibits T{sub e} sufficiently low for this instability to occur. Indeed, previous experiments have revealed that such lamps develop, under certain conditions, voltage oscillations accompanied by electromagnetic interference, and this instability has been pinned down to the plasma-anode interaction. A relation between the mechanisms of the considered instability and multiple anodic attachments of high-pressure arcs is discussed.

  4. Promoting Literacy and Protection with Solar Lamps in Yemen

    Directory of Open Access Journals (Sweden)

    Jerry Farrell

    2014-04-01

    Full Text Available By distributing solar lamps to vulnerable rural women in Yemen, we promoted enrollment in literacy programs, as well as reading among their children. We saw a number of secondary benefits as well: safer households where dangerous kerosene lamps were used less frequently in the evening; a number of livelihood activities - cooking, husbandry, handicrafts - continued safely into evening hours; children found it easier to work on their homework using the solar powered lamps; and children found it easier and safer to walk in dark, rural streets in the evening with the solar lamps slung around their necks.

  5. Heat transfer assembly for a fluorescent lamp and fixture

    Science.gov (United States)

    Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

    1992-12-29

    In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

  6. Ammonia Synthesis at Low Pressure.

    Science.gov (United States)

    Cussler, Edward; McCormick, Alon; Reese, Michael; Malmali, Mahdi

    2017-08-23

    Ammonia can be synthesized at low pressure by the use of an ammonia selective absorbent. The process can be driven with wind energy, available locally in areas requiring ammonia for synthetic fertilizer. Such wind energy is often called "stranded," because it is only available far from population centers where it can be directly used. In the proposed low pressure process, nitrogen is made from air using pressure swing absorption, and hydrogen is produced by electrolysis of water. While these gases can react at approximately 400 °C in the presence of a promoted conventional catalyst, the conversion is often limited by the reverse reaction, which makes this reaction only feasible at high pressures. This limitation can be removed by absorption on an ammine-like calcium or magnesium chloride. Such alkaline metal halides can effectively remove ammonia, thus suppressing the equilibrium constraints of the reaction. In the proposed absorption-enhanced ammonia synthesis process, the rate of reaction may then be controlled not by the chemical kinetics nor the absorption rates, but by the rate of the recycle of unreacted gases. The results compare favorably with ammonia made from a conventional small scale Haber-Bosch process.

  7. System transient analysis code development for low pressure and low power

    International Nuclear Information System (INIS)

    Kim, Hee Cheol

    1998-02-01

    A real time reactor system analysis code, ARTIST, based on drift flux model has been developed to investigate the transient system behavior under low pressure, low flow and low power conditions with noncondensable gas present in the system. The governing equations of the ARTIST code consist of three mass continuity equations (steam, liquid and noncondensable), two energy equations (gas and mixture) and one momentum equation (mixture) constituted with the drift flux model. The capability of ARTIST in predicting two-phase flow void distribution in the system has been validated against experimental data. The results of the ARTIST axial void distribution at low pressure and low flow, are far better than the results of both the homogeneous model of TASS code and the two-fluid model of RELAP5/MOD3 code. Also, RELAP5/MOD3 calculation shows the large amplitude of void fraction oscillations at low pressure. These results imply that interfacial momentum transfer terms in the two-fluid model formulation should be carefully constituted, especially for the low pressure condition due to the big density differences between steam and water. Thermal-hydraulic state solution scheme is developed when noncondensable gas exists. Numerical consistency and convergence of obtaining equilibrium state is tested with the ideal problems for various situations including very low partial pressure conditions. Calculated thermal-hydraulic state for each test shows consistent and expected behaviour. A new multi-layer back propagation network algorithm for calculating the departure from nucleate boiling ratio (DNBR) is developed and adopted in ARTIST code in order to have real-time DNBR evaluation by eliminating the tandem procedure of the transient DNBR calculation. The algorithm trained by different patterns generated by latin hypercube sampling method on the performance space is tested for the randomly sampled untrained data and the transient DNBR data. The uncertainty of the algorithm is

  8. [Reduced muscular oxygen tension and nerve impulse transmission from antishock hose. Reduction of oxygen tension in the tibial muscle and impulse transmission in the peroneal nerve from pneumatic -1 pressure from antishock hose].

    Science.gov (United States)

    Willy, C; Völker, H U; Weber, F; Albert, U; Sterk, J; Helm, M; Gerngross, H; Thomas, A

    1998-07-01

    The aim of the study was to assess, whether the pneumatic pressure of an antishock-trouser (AST) of 20-40 mm Hg induces a decreased oxygenation of the anterior tibial muscle and attenuates muscular response potential (MRP) of n. peronaeus profundus? Among 22 normotensive, healthy volunteers the AST were tested by applying pressure values between 0 and 100 mm Hg and measuring the intracompartmental pressure, the muscular oxygen pressure as well as the MRP by electroneurographic means within a period of 6 hours. The median initial intracompartmental pressure value of the m. tibialis anterior was 12.0 mm Hg (Q25%/Q75%: 8.9/17.3), the muscular oxygen pressure 14.8 mm Hg (Q25%/Q75%: 11.5/22.0). Transmission of the pneumatic AST-leg segment pressure to the muscle: 97.7% (Q25%/Q75%: 89.2/99.8). Already in the low AST pressure field (20-40 mm Hg) a severe hypoxia occurred in one case. A reduction of MRP was noticed at an AST pressure rate of 10 mm Hg. In 5 of 6 cases AST pressure values of 60 mm Hg led to pathological pO2-values within 5-20 minutes. Almost without exception AST-pressure rates < 60 mm Hg resulted in an anoxia of the muscle and loss of the MRP. We should demand that the AST are only applied with models where the pressure generated within the single segments can be controlled by pressure gauge. The application of the AST seems to be justified for polytraumatised in severe haemorrhagic shock where the risk of a local tissue ischemia with systemical consequences must deliberately be accepted.

  9. Development and commercialisation of rechargeable wooden LED lamps

    Directory of Open Access Journals (Sweden)

    Bradley Schultz

    2013-02-01

    Full Text Available The focus of this project was to work with local staff at Kathmandu Alternative Power and Energy Group to commercialise a product which would generate recurring income for the organisation, to enable staff to learn the process of commercialisation and to provide employment and skills in the local community. Rechargeable Light Emitting Diode (LED lamps were deemed suitable for these aims, as they are a simple product, yet one that is urgently required in Nepal due to the prevalence of ‘load-shedding’ – scheduled electrical blackouts. After reviewing the market, it was found that it would be impossible to compete with the price of cheap imported Chinese rechargeable LED lamps, so an alternative approach was taken. This involved sourcing wooden off-cuts from a local furniture factory and transforming them into attractive desk lamps, with the target market being affluent Nepalis, ex-pats living in Nepal and tourists. Successful initial sales were achieved through a Kathmandu-based ex-pat email group, hotel-markets and souvenir stores. KAPEG staff have continued the project, producing variations on the initial design including Himalayan rock salt lamps, employing local people to manufacture lamps and selling them at markets in Kathmandu. Staffing and marketing challenges remain to ensure the lamp manufacture and sales continue.

  10. 40 CFR 60.4112 - Changing Hg designated representative and alternate Hg designated representative; changes in...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Changing Hg designated representative and alternate Hg designated representative; changes in owners and operators. 60.4112 Section 60.4112... Generating Units Hg Designated Representative for Hg Budget Sources § 60.4112 Changing Hg designated...

  11. Elastic, dynamical, and electronic properties of LiHg and Li3Hg: First-principles study

    Science.gov (United States)

    Wang, Yan; Hao, Chun-Mei; Huang, Hong-Mei; Li, Yan-Ling

    2018-04-01

    The elastic, dynamical, and electronic properties of cubic LiHg and Li3Hg were investigated based on first-principles methods. The elastic constants and phonon spectral calculations confirmed the mechanical and dynamical stability of the materials at ambient conditions. The obtained elastic moduli of LiHg are slightly larger than those of Li3Hg. Both LiHg and Li3Hg are ductile materials with strong shear anisotropy as metals with mixed ionic, covalent, and metallic interactions. The calculated Debye temperatures are 223.5 K and 230.6 K for LiHg and Li3Hg, respectively. The calculated phonon frequency of the T2 g mode in Li3Hg is 326.8 cm-1. The p states from the Hg and Li atoms dominate the electronic structure near the Fermi level. These findings may inspire further experimental and theoretical study on the potential technical and engineering applications of similar alkali metal-based intermetallic compounds.

  12. Equilibrium Sorption Studies of Hg (II) Ions from Aqueous Solution ...

    African Journals Online (AJOL)

    The potential of swamp arum (Lasimorpha senegalensis) seeds as a low-cost adsorbent for the removal of Hg (II) ions from aqueous solution was investigated in this study. The influence of initial metal concentration on the percent adsorption of Hg (II) ions onto powdered swamp arum seeds was studied in a batch system ...

  13. Associations between bacterial infections and blood pressure in pregnancy.

    Science.gov (United States)

    Petry, Clive J; Ong, Ken K; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2017-10-01

    To test the hypothesis that bacterial infections in pregnancy are related to maternal blood pressure. Bacterial infection was assessed using antibiotic usage as a surrogate and its association with blood pressure in pregnancy tested in the Cambridge Baby Growth Study. Antibiotic usage in pregnancy was self-reported in questionnaires. Blood pressure measurements at four time points in pregnancy were collected from the hospital notes of 622 women. Using all the available blood pressure readings (adjusted for weeks gestation) antibiotic usage was associated with a higher mean arterial blood pressure across pregnancy: antibiotics used 85(84, 87)mmHg vs. no antibiotics used 83 (83, 84) mmHg (β=2.3 (0.6, 4.0) mmHg, p=9.6×10 -3 , from 621 individuals). Further analysis revealed that antibiotic usage was associated with diastolic (β=2.3 (0.6, 4.0) mmHg; p=7.0×10 -3 ) more than systolic blood pressure (β=1.4(-0.9, 3.7)mmHg; p=0.2). The effect size associated with antibiotic usage appeared to rise slightly after the first trimester. Bacterial infection in pregnancy, as assessed by self-reported antibiotic usage, is associated with small rises in blood pressure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  14. Just passing through --- high Hg deposition to Puerto Rico forest moves quickly off the landscape

    Science.gov (United States)

    Shanley, J. B.; Willenbring, J. K.; Kaste, J. M.; Occhi, M.; McDowell, W. H.

    2012-12-01

    Atmospheric mercury (Hg) in wet deposition at the Luquillo Experimental Forest in northeastern Puerto Rico, averages 28 μg m-2 yr-1, higher than any site in the USA Mercury Deposition Network. Despite the high deposition, Hg content of soils, vegetation, and biota are below global averages. The low Hg content of watershed surfaces, coupled with exceptionally high stream total Hg flux, suggest that most of the Hg passes through the watershed with minimal retention. We assessed Hg dynamics in two adjacent watersheds, Rio Icacos underlain by quartz diorite, and Rio Mameyes underlain by volcaniclastic rocks. At both sites, high-flow Hg concentrations approached 100 ng L-1, dominated by particulate Hg. In order to assess the apparent pass-through nature of Hg in this tropical forest, we measured 7Be and 10Be isotopes from natural, cosmogenic fallout adsorbed on stream suspended particles to constrain the Hg age /residence time and source (atmospheric vs. geogenic or legacy Hg from 19th century gold mining). Ubiquitous 7Be (half-life 53 days) and relatively high 7Be/10Be ratios on suspended particles suggest that stream Hg was dominated by erosion from exposed surfaces, supporting a short residence time. The low watershed retention of the high Hg throughput limits adverse biological effects in this tropical ecosystem.

  15. Intraocular pressure measurement in patients with previous LASIK surgery using pressure phosphene tonometer.

    Science.gov (United States)

    Cheng, Arthur C K; Leung, Dexter Y L; Cheung, Eva Y Y; Fan, Dorothy S P; Law, Ricky W K; Lam, Dennis S C

    2005-04-01

    To compare intraocular pressure (IOP) assessment in post-LASIK patients using non-contact tonometry, pressure phosphene tonometry and applanation tonometry. Sixty-two consecutive LASIK patients were analysed preoperatively and postoperatively with non-contact, pressure phosphene and applanation tonometry. Comparisons among these values were assessed with paired sample Student t-test, Pearson's correlation test and Bland-Altman plotting. There was no significant difference for preoperative IOP measurement between non-contact, pressure phosphene and applanation tonometry. The mean +/-SD difference between the preoperative non-contact tonometry and postoperative pressure phosphene tonometry IOP measurements was 0.80 +/- 2.77 mmHg (P contact tonometry significantly underestimated IOP measurement by 9.96 +/- 2.25 mmHg (P < 0.001). Pressure phosphene tonometry may provide an alternative method for the assessment of IOP in post-LASIK patients.

  16. Spectra of Th/Ar and U/Ne hollow cathode lamps for spectrograph calibration

    Science.gov (United States)

    Nave, Gillian; Shlosberg, Ariel; Kerber, Florian; Den Hartog, Elizabeth; Neureiter, Bianca

    2018-01-01

    Low-current Th/Ar hollow cathode lamps have long been used for calibration of astronomical spectrographs on ground-based telescopes. Thorium is an attractive element for calibration as it has a single isotope, has narrow spectral lines, and has a dense spectrum covering the whole of the visible region. However, the high density of the spectrum that makes it attractive for calibrating high-resolution spectrographs is a detriment for lower resolution spectrographs and this is not obvious by examination of existing linelists. In addition, recent changes in regulations regarding the handling of thorium have led to a degradation in the quality of Th/Ar calibration lamps, with contamination by molecular ThO lines that are strong enough to obscure the calibration lines of interest.We are pursuing two approaches to these problems. First, we have expanded and improved the NIST Standard Reference Database 161, "Spectrum of Th-Ar Hollow Cathode Lamps" to cover the region 272 nm to 5500 nm. Spectra of hollow cathode lamps at up to 3 different currents can now be displayed simultaneously. Interactive zooming and the ability to convolve any of the spectra with a Gaussian or uploaded instrument profile enable the user to see immediately what the spectrum would look like at the particular resolution of their spectrograph. Second, we have measured the spectrum of a recent, contaminated Th/Ar hollow cathode lamp using a high-resolution Echelle spectrograph (Madison Wisconsin) at a resolving power (R~ 250,000). This significantly exceeds the resolving power of most astronomical spectrographs and resolves many of the molecular lines of ThO. With these spectra we are measuring and calibrating the positions of these molecular lines in order to make them suitable for spectrograph calibration.In the near infrared region, U/Ne hollow cathode lamps give a higher density of calibration lines than Th/Ar lamps and will be implemented on the upgraded CRIRES+ spectrograph on ESO’s Very Large

  17. The calorically restricted low-fat nutrient-dense diet in Biosphere 2 significantly lowers blood glucose, total leukocyte count, cholesterol, and blood pressure in humans.

    Science.gov (United States)

    Walford, R L; Harris, S B; Gunion, M W

    1992-12-01

    Biosphere 2 is a 3.15-acre space containing an ecosystem that is energetically open (sunlight, electric power, and heat) but materially closed, with air, water, and organic material being recycled. Since September 1991, eight subjects (four women and four men) have been sealed inside, living on food crops grown within. Their diet, low in calories (average, 1780 kcal/day; 1 kcal = 4.184 kJ), low in fat (10% of calories), and nutrient-dense, conforms to that which in numerous animal experiments has promoted health, retarded aging, and extended maximum life span. We report here medical data on the eight subjects, comparing preclosure data with data through 6 months of closure. Significant changes included: (i) weight, 74 to 62 kg (men) and 61 to 54 kg (women); (ii) mean systolic/diastolic blood pressure (eight subjects), 109/74 to 89/58 mmHg (1 mmHg = 133 Pa); (iii) total serum cholesterol, from 191 +/- 11 to 123 +/- 9 mg/dl (mean +/- SD; 36% mean reduction), and high density lipoprotein, from 62 +/- 8 to 38 +/- 5 (risk ratio unchanged); (iv) triglyceride, 139 to 96 mg/dl (men) and 78 to 114 mg/dl (women); (v) fasting glucose, 92 to 74 mg/dl; (vi) leukocyte count, 6.7 to 4.7 x 10(9) cells per liter. We conclude that drastic reductions in cholesterol and blood pressure may be instituted in normal individuals in Western countries by application of a carefully chosen diet and that a low-calorie nutrient-dense regime shows physiologic features in humans similar to those in other animal species.

  18. Triaxiality in the even-mass Hg isotopes: A discontinuity at 200Hg

    International Nuclear Information System (INIS)

    Morrison, I.; Spear, R.H.

    1981-01-01

    The mass dependence of excitation energies of the 2 + 1 , 2 + 2 , and 4 + 1 states of the even-mass Hg isotopes, and of some related B(E2) values, shows a marked discontinuity at 200 Hg. Analysis of B(E2;0 + 1 →2 + 1 ) values in terms of an extended interacting boson approximation model suggests that this discontinuity is due to a change in the proton and neutron distributions at 200 Hg. Apart from 200 Hg, the data favor γ-soft models rather than the rigid triaxial-rotor model

  19. Color Degradation of Textiles with Natural Dyes and of Blue Scale Standards Exposed to White LED Lamps:Evaluation of White LED Lamps for Effectiveness as Museum Lighting

    Science.gov (United States)

    Ishii, Mie; Moriyama, Takayoshi; Toda, Masahiro; Kohmoto, Kohtaro; Saito, Masako

    White light-emitting diodes (LED) are well suited for museum lighting because they emit neither UV nor IR radiation, which damage artifacts. The color degradation of natural dyes and blue scale standards (JIS L 0841) by white LED lamps are examined, and the performance of white LED lamps for museum lighting is evaluated. Blue scale standard grades 1-6 and silk fabrics dyed with 22 types of natural dyes classified as mid to highly responsive in a CIE technical report (CIE157:2004) were exposed to five types of white LED lamps using different luminescence methods and color temperatures. Color changes were measured at each 15000 lx·hr (500 lx at fabric surface × 300 hr) interval ten times. The accumulated exposure totaled 150000 lx·hr. The data on conventional white LED lamps and previously reported white fluorescent (W) and museum fluorescent (NU) lamps was evaluated. All the white LED lamps showed lower fading rates compared with a W lamp on a blue scale grade 1. The fading rate of natural dyes in total was the same between an NU lamp (3000 K) and a white LED lamp (2869 K). However, yellow natural dyes showed higher fading rates with the white LED lamp. This tendency is due to the high power characteristic of the LED lamp around 400-500 nm, which possibly contributes to the photo-fading action on the dyes. The most faded yellow dyes were Ukon (Curcuma longa L.) and Kihada (Phellodendron amurense Rupr.), and these are frequently used in historic artifacts such as kimono, wood-block prints, and scrolls. From a conservation point of view, we need to continue research on white LED lamps for use in museum lighting.

  20. On the mean square displacements (MSD) of Hg and Te in HgTe

    International Nuclear Information System (INIS)

    Madhavan, Y.; Ramachandran, K.

    1989-01-01

    The mean square displacements (MSD) of Hg and Te in the perfect system of HgTe are worked out in the modified rigid ion model of Plumelle and Vandevyver. Also the MSD of Hg and Te neighbours around anion and cation vacancies in HgTe are worked out giving an active role for the vacancy following the theory of Maradudin et al. The results are compared with experimental values. (author)

  1. Vehicle kinematics in turns and the role of cornering lamps in driver vision.

    Science.gov (United States)

    2010-11-01

    "SAE Recommended Practice J852 and ECE Regulations 119 and 48 for cornering lamps : were compared. Photometric points described in each specification were then compared : to naturalistic low-speed turn trajectories produced by 87 drivers. Future loca...

  2. Lattice defects in semiconducting Hg/1-x/Cd/x/Te alloys. I - Defect structure of undoped and copper doped Hg/0.8/Cd/0.2/Te. II - Defect structure of indium-doped Hg/0.8/Cd/0.2/Te

    Science.gov (United States)

    Vydyanath, H. R.

    1981-01-01

    Hall effect and mobility measurements were conducted on undoped Hg(0.8)Cd(0.2)Te crystals which were quenched to room temperature after being subjected to equilibration at temperatures ranging from 400 to 655 C in various Hg atmospheres. The variation of the hole concentration in the cooled crystals at 77 K as a function of Hg's partial pressure at the equilibration temperature, together with a comparison of the hole mobility in the undoped samples with that in copper-doped ones, yields a defect model for the undoped crystals according to which they are intrinsic at the equilibration temperatures and the native acceptor defects are doubly ionized. In the second part of this paper, the effects of indium doping are considered. The concentration of electrons obtained in the cooled crystals was found to be lower than the intrinsic carrier concentration at the equilibration temperatures. A defect model is proposed according to which most of the indium is incorporated as In2Te3(s) dissolved in the crystal, with only a small fraction of indium acting as single donors occupying Hg lattice sites.

  3. Tanning lamps ultraviolet emissions and compliance with technical standards

    International Nuclear Information System (INIS)

    Bonino, A.; Facta, S.; Saudino, S.; Anglesio, L.; D'Amore, G.

    2009-01-01

    In this work the compliance of tanning lamps with technical standards EN 60335-2-27 'Household and similar electrical appliances-Safety. Part 2: Particular requirements for appliances for skin exposure to ultraviolet and infrared radiation' was analysed. Results of this analysis showed that none of the examined technical documentation produced by the lamps manufacturers is fully compliant with the standard technique. Furthermore data reported in the same manuals, such as effective radiant exposure or irradiance, would indicate that these sources may be the cause of undue exposure to ultraviolet (UV) radiation. For this reason a measurement campaign on UV lamps used in tanning salons was organised. The first results of these measurements seem to confirm the doubts raised from the analysis of the lamp manuals: the use of a tanning lamp can lead to UV radiation exposure levels higher than reference maximum values recommended by EN 60335-2-27. (authors)

  4. Ultrasonic nebulization extraction/low pressure photoionization mass spectrometry for direct analysis of chemicals in matrices.

    Science.gov (United States)

    Liu, Chengyuan; Zhu, Yanan; Zhou, Zhongyue; Yang, Jiuzhong; Qi, Fei; Pan, Yang

    2015-09-03

    A novel ultrasonic nebulization extraction/low-pressure photoionization (UNE-LPPI) system has been designed and employed for the rapid mass spectrometric analysis of chemicals in matrices. An ultrasonic nebulizer was used to extract the chemicals in solid sample and nebulize the solvent in the nebulization cell. Aerosols formed by ultrasonic were evaporated by passing through a transferring tube, and desolvated chemicals were ionized by the emitted light (10.6 eV) from a Krypton discharge lamp at low pressure (∼68 Pa). First, a series of semi/non-volatile compounds with different polarities, such as polycyclic aromatic hydrocarbons (PAHs), amino acids, dipeptides, drugs, nucleic acids, alkaloids, and steroids were used to test the system. Then, the quantification capability of UNE-LPPI was checked with: 1) pure chemicals, such as 9,10-phenanthrenequinone and 1,4-naphthoquinone dissolved in solvent; 2) soil powder spiked with different amounts of phenanthrene and pyrene. For pure chemicals, the correlation coefficient (R(2)) for the standard curve of 9,10-phenanthrenequinone in the range of 3 ng-20 μg mL(-1) was 0.9922, and the measured limits of detection (LOD) was 1 ng ml(-1). In the case of soil powder, linear relationships for phenanthrene and pyrene from 10 to 400 ng mg(-1) were obtained with correlation coefficients of 0.9889 and 0.9893, respectively. At last, the feasibility of UNE-LPPI for the detection of chemicals in real matrices such as tablets and biological tissues (tea, Citrus aurantium peel and sage (Salvia officinalis) leaf) were successfully demonstrated. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Effects of mercury on the arterial blood pressure of anesthetized rats

    Directory of Open Access Journals (Sweden)

    Rossoni L.V.

    1999-01-01

    Full Text Available The available data suggests that hypotension caused by Hg2+ administration may be produced by a reduction of cardiac contractility or by cholinergic mechanisms. The hemodynamic effects of an intravenous injection of HgCl2 (5 mg/kg were studied in anesthetized rats (N = 12 by monitoring left and right ventricular (LV and RV systolic and diastolic pressures for 120 min. After HgCl2 administration the LV systolic pressure decreased only after 40 min (99 ± 3.3 to 85 ± 8.8 mmHg at 80 min. However, RV systolic pressure increased, initially slowly but faster after 30 min (25 ± 1.8 to 42 ± 1.6 mmHg at 80 min. Both right and left diastolic pressures increased after HgCl2 treatment, suggesting the development of diastolic ventricular dysfunction. Since HgCl2 could be increasing pulmonary vascular resistance, isolated lungs (N = 10 were perfused for 80 min with Krebs solution (continuous flow of 10 ml/min containing or not 5 µM HgCl2. A continuous increase in pulmonary vascular resistance was observed, suggesting the direct effect of Hg2+ on the pulmonary vessels (12 ± 0.4 to 29 ± 3.2 mmHg at 30 min. To examine the interactions of Hg2+ and changes in cholinergic activity we analyzed the effects of acetylcholine (Ach on mean arterial blood pressure (ABP in anesthetized rats (N = 9 before and after Hg2+ treatment (5 mg/kg. Using the same amount and route used to study the hemodynamic effects we also examined the effects of Hg2+ administration on heart and plasma cholinesterase activity (N = 10. The in vivo hypotensive response to Ach (0.035 to 10.5 µg was reduced after Hg2+ treatment. Cholinesterase activity (µM h-1 mg protein-1 increased in heart and plasma (32 and 65%, respectively after Hg2+ treatment. In conclusion, the reduction in ABP produced by Hg2+ is not dependent on a putative increase in cholinergic activity. HgCl2 mainly affects cardiac function. The increased pulmonary vascular resistance and cardiac failure due to diastolic

  6. Calibration of Relative Humidity Devices in Low-pressure, Low-temperature CO2 Environment

    Science.gov (United States)

    Genzer, Maria; Polkko, Jouni; Nikkanen, Timo; Hieta, Maria; Harri, Ari-Matti

    2017-04-01

    Calibration of relative humidity devices requires in minimum two humidity points - dry (0%RH) and (near)saturation (95-100%RH) - over the expected operational temperature and pressure range of the device. In terrestrial applications these are relatively easy to achieve using for example N2 gas as dry medium, and water vapor saturation chambers for producing saturation and intermediate humidity points. But for example in applications intended for meteorological measurements on Mars there is a need to achieve at least dry and saturation points in low-temperature, low-pressure CO2 environment. We have developed a custom-made, small, relatively low-cost calibration chamber able to produce both dry points and saturation points in Martian range pressure CO2, in temperatures down to -70°C. The system utilizes a commercially available temperature chamber for temperature control, vacuum vessels and pumps. The main pressure vessel with the devices under test inside is placed inside the temperature chamber, and the pressure inside is controlled by pumps and manual valves and monitored with a commercial pressure reference with calibration traceable to national standards. Air, CO2, or if needed another gas like N2, is used for filling the vessel until the desired pressure is achieved. Another pressure vessel with a dedicated pressure pump is used as the saturation chamber. This vessel is placed in the room outside the temperature chamber, partly filled with water and used for achieving saturated water vapor in room-temperature low-pressure environment. The saturation chamber is connected to the main pressure vessel via valves. In this system dry point, low-pressure CO2 environment is achieved by filling the main pressure vessel with dry CO2 gas until the desired pressure is achieved. A constant flow of gas is maintained with the pump and valves and monitored with the pressure reference. The saturation point is then achieved by adding some water vapor from the saturation

  7. Effect of flow rate and temperature on transmembrane blood pressure drop in an extracorporeal artificial lung.

    Science.gov (United States)

    Park, M; Costa, E L V; Maciel, A T; Barbosa, E V S; Hirota, A S; Schettino, G de P; Azevedo, L C P

    2014-11-01

    Transmembrane pressure drop reflects the resistance of an artificial lung system to blood transit. Decreased resistance (low transmembrane pressure drop) enhances blood flow through the oxygenator, thereby, enhancing gas exchange efficiency. This study is part of a previous one where we observed the behaviour and the modulation of blood pressure drop during the passage of blood through artificial lung membranes. Before and after the induction of multi-organ dysfunction, the animals were instrumented and analysed for venous-venous extracorporeal membrane oxygenation, using a pre-defined sequence of blood flows. Blood flow and revolutions per minute (RPM) of the centrifugal pump varied in a linear fashion. At a blood flow of 5.5 L/min, pre- and post-pump blood pressures reached -120 and 450 mmHg, respectively. Transmembrane pressures showed a significant spread, particularly at blood flows above 2 L/min; over the entire range of blood flow rates, there was a positive association of pressure drop with blood flow (0.005 mmHg/mL/minute of blood flow) and a negative association of pressure drop with temperature (-4.828 mmHg/(°Celsius). These associations were similar when blood flows of below and above 2000 mL/minute were examined. During its passage through the extracorporeal system, blood is exposed to pressure variations from -120 to 450 mmHg. At high blood flows (above 2 L/min), the drop in transmembrane pressure becomes unpredictable and highly variable. Over the entire range of blood flows investigated (0-5500 mL/min), the drop in transmembrane pressure was positively associated with blood flow and negatively associated with body temperature. © The Author(s) 2014.

  8. Correlates of blood pressure in Yanomami Indians of northwestern Brazil.

    Science.gov (United States)

    Crews, D E; Mancilha-Carvalho, J J

    1993-01-01

    We determined associations of measures of body habitus with blood pressure for 100 adult Yanomami Indians (61 men, 39 women) examined during February and March 1990. Measurements included body weight and height, four skinfolds (triceps, subscapular, suprailiac, abdomen), four circumferences (wrist, upper arm, abdomen, hip), systolic and diastolic blood pressures, pulse rate, and estimated age. Various indices of fat distribution were determined from the measurements of skinfolds, circumferences, weight, and height. Estimated age averaged 35.0 years in men and 33.4 years in women (range: 15 to 63 years). Mean systolic and diastolic blood pressures were low in both men (104.8/70.4 mm Hg) and women (94.8/63.5 mm Hg), as was body mass index (men: 20.7; women: 21.4 kg/m2). In Yanomami women, all four skinfolds, wrist circumference, and the indices of hip and abdominal fat were significant correlates of systolic blood pressure, while the abdominal skinfold and wrist and hip circumferences correlated significantly with diastolic blood pressure. Among men, there was a negative correlation between estimated age and systolic blood pressure and a positive correlation between BMI and upper arm and hip circumferences and systolic blood pressure. There was a significant positive correlation between wrist, upper arm, and hip circumferences and diastolic blood pressure among Yanomami men. We used stepwise regression to generate sex-specific predictive equations for blood pressure. For men, estimated age and hip circumference, and for women, abdominal skinfold measurement and age were included in the model for systolic blood pressure. Among men, wrist circumference and height, and among women, wrist circumference alone entered the model for diastolic blood pressure. On the basis of these results, we suggest that even in a low-blood pressure, low-body fat, no-salt setting, systolic blood pressure is associated with the amount and placement of adipose tissue. However, diastolic blood

  9. Definition of a high intensity metal halide discharge reference lamp

    NARCIS (Netherlands)

    Stoffels, W.W.; Baede, A.H.F.M.; Mullen, van der J.J.A.M.; Haverlag, M.; Zissis, G.

    2006-01-01

    The design of a ref. metal halide discharge lamp is presented. This lamp is meant as a common study object for researchers working on metal halide discharge lamps, who by using the same design will be able to compare results between research groups, diagnostic techniques and numerical models. The

  10. The effect of the rate of hydrostatic pressure depressurization on cells in culture.

    Science.gov (United States)

    Tworkoski, Ellen; Glucksberg, Matthew R; Johnson, Mark

    2018-01-01

    Changes in hydrostatic pressure, at levels as low as 10 mm Hg, have been reported in some studies to alter cell function in vitro; however, other studies have found no detectable changes using similar methodologies. We here investigate the hypothesis that the rate of depressurization, rather than elevated hydrostatic pressure itself, may be responsible for these reported changes. Hydrostatic pressure (100 mm Hg above atmospheric pressure) was applied to bovine aortic endothelial cells (BAECs) and PC12 neuronal cells using pressurized gas for periods ranging from 3 hours to 9 days, and then the system was either slowly (~30 minutes) or rapidly (~5 seconds) depressurized. Cell viability, apoptosis, proliferation, and F-actin distribution were then assayed. Our results did not show significant differences between rapidly and slowly depressurized cells that would explain differences previously reported in the literature. Moreover, we found no detectable effect of elevated hydrostatic pressure (with slow depressurization) on any measured variables. Our results do not confirm the findings of other groups that modest increases in hydrostatic pressure affect cell function, but we are not able to explain their findings.

  11. Tourniquet pressures: strap width and tensioning system widths.

    Science.gov (United States)

    Wall, Piper L; Coughlin, Ohmar; Rometti, Mary; Birkholz, Sarah; Gildemaster, Yvonne; Grulke, Lisa; Sahr, Sheryl; Buising, Charisse M

    2014-01-01

    Pressure distribution over tourniquet width is a determinant of pressure needed for arterial occlusion. Different width tensioning systems could result in arterial occlusion pressure differences among nonelastic strap designs of equal width. Ratcheting Medical Tourniquets (RMTs; m2 inc., http://www.ratcheting buckles.com) with a 1.9 cm-wide (Tactical RMT) or 2.3 cm-wide (Mass Casualty RMT) ladder were directly compared (16 recipients, 16 thighs and 16 upper arms for each tourniquetx2). Then, RMTs were retrospectively compared with the windlass Combat Application Tourniquet (C-A-T ["CAT"], http://combattourniquet.com) with a 2.5 cm-wide internal tensioning strap. Pressure was measured with an air-filled No. 1 neonatal blood pressure cuff under each 3.8 cm-wide tourniquet. RMT circumferential pressure distribution was not uniform. Tactical RMT pressures were not higher, and there were no differences between the RMTs in the effectiveness, ease of use ("97% easy"), or discomfort. However, a difference did occur regarding tooth skipping of the pawl during ratchet advancement: it occurred in 1 of 64 Tactical RMT applications versus 27 of 64 Mass Casualty RMT applications. CAT and RMT occlusion pressures were frequently over 300 mmHg. RMT arm occlusion pressures (175-397 mmHg), however, were lower than RMT thigh occlusion pressures (197-562 mmHg). RMT effectiveness was better with 99% reached occlusion and 1% lost occlusion over 1 minute versus the CAT with 95% reached occlusion and 28% lost occlusion over 1 minute. RMT muscle tension changes (up to 232 mmHg) and pressure losses over 1 minute (24±11 mmHg arm under strap to 40±12 mmHg thigh under ladder) suggest more occlusion losses may have occurred if tourniquet duration was extended. The narrower tensioning system Tactical RMT has better performance characteristics than the Mass Casualty RMT. The 3.8 cm-wide RMTs have some pressure and effectiveness similarities and differences compared with the CAT. Clinically

  12. Efficient, full-spectrum, long-lived, non-toxic microwave lamp for plant growth

    Energy Technology Data Exchange (ETDEWEB)

    MacLennan, D.A.; Turner, B.P.; Dolan, J.T.; Ury, M.G.; Gustafson, P. [Fusion Systems Corp., Rockville, MD (United States)

    1994-12-31

    Fusion Systems Corporation has developed a mercury-free, low infra-red, efficient microwave lamp using a benign sulfur based fill optimized for visible light. Our literature search and discussions with researchers directed us to enhance the bulbs red output. We have demonstrated a photosynthetic efficacy of over 2 micro-moles per microwave joule which corresponds to over 1.3 micro-moles per joule at the power main. Recent work has shown we can make additional increases in overall system efficiency. During the next two years, we expect to demonstrate a system capable of producing more than 1.5 micro-moles/joule measured at the power main with significantly less IR than alternative lamp systems.

  13. CALiPER Application Summary Report 21. Linear (T8) LED Lamps

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-03-01

    This report focuses on the bare lamp performance of 31 linear LED lamps intended as an alternative to T8 fluorescent lamps. Data obtained in accordance with IES LM-79-08 indicated that the mean efficacy is similar to that of fluorescent lamps, but that lumen output is often much lower. This presents a situation where something must change in order for energy savings and equivalent illumination levels to be achieved simultaneously. In this case, the luminous intensity distribution of all the tested lamps was directional or semi-directional, rather than omnidirectional. Also discussed in this report are several issues related to the electrical configuration of the lamps, such as the required socket types and power feed location. While no configuration is necessarily better, the multitude of options can make specifying and installing linear LED lamps more difficult, with the potential for safety issues. Similarly, the variety of color and power quality attributes adds a layer of complexity to the specification process. Many products offered good or excellent quality attributes, but some did not and thus could be perceived as inferior to fluorescent lamps in some installations.

  14. Effect of antecedent hypertension and follow-up blood pressure on outcomes after high-risk myocardial infarction

    DEFF Research Database (Denmark)

    Thune, J.J.; Signorovitch, J.; Velazquez, E.J.

    2007-01-01

    myocardial infarction in the Valsartan in Myocardial Infarction Trial. We assessed the relationship between antecedent hypertension and outcomes and the association between elevated (systolic: >140 mm Hg) or low blood pressure (systolic:

  15. Influence of short-term blood pressure variability on blood pressure determinations

    NARCIS (Netherlands)

    Bos, W. J.; van Goudoever, J.; van Montfrans, G. A.; Wesseling, K. H.

    1992-01-01

    To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial

  16. Improvement of Diurnal Blood Pressure Variation by Azilsartan.

    Science.gov (United States)

    Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori

    2018-01-01

    Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers.

  17. Hyperemesis Gravidarum (HG)

    Science.gov (United States)

    ... Treatments Risks Complications Impact Take a Poll If HG continued past mid-pregnancy , did you experience complications ... Understanding Hyperemesis | Overview About Hyperemesis Gravidarum Hyperemesis gravidarum (HG) is a severe form of nausea and vomiting ...

  18. Stability and diffusion of Hg implanted YBa2Cu3O6+x

    International Nuclear Information System (INIS)

    Araujo, J.P.; Correia, J.G.; Wahl, U.; Marques, J.G.; Alves, E.; Amaral, V.S.; Lourenco, A.A.; Galindo, V.; Papen, T. von; Senateur, J.P.; Weiss, F.; Vantomme, A.; Langouche, G.; Melo, A.A.; Silva, M.F. da; Soares, J.C.; Sousa, J.B.

    1999-01-01

    The radioactive isotope 197m Hg was implanted at 60 keV with low fluences (10 13 ions/cm 2 ) into YBa 2 Cu 3 O 6+x (YBCO) superconducting thin films at ISOLDE/CERN. We report on the Hg dynamics and stability inside the YBCO lattice as a function of annealing temperature up to 890 K in a vacuum or O 2 atmosphere. The perturbed angular correlation (PAC) technique was used for probing the Hg behavior at the atomic scale, while by monitoring the sample's activity in situ the Hg outdiffusion was studied. We found that Hg ions occupy unique lattice sites and that Hg should be bound to two apical oxygens. Hg diffusion occurs only for annealing temperatures above 653 K, in vacuum. The Hg migration energy was estimated to be E M =1.58±0.15 eV

  19. Experimental study an a low pressure solar still

    International Nuclear Information System (INIS)

    Sriram, V.; Kalidasa Murugavel, K.; Samuel Hansen, R.

    2013-01-01

    In this work, a low pressure, single basin double slope Solar Still was fabricated and tested for different depths and with different wick and porous materials. A vacuum pump was used to maintain low pressure inside the still. External condenser was used to condense the vapor with raw water as cooling fluid. The performance of the low pressure still was compared with conventional still. The total production of the still was increased by 88.66% when a light cotton cloth was used as wick material in the basin along with minimum depth of water. (authors)

  20. Low level and sub-chronic exposure to methylmercury induces hypertension in rats: nitric oxide depletion and oxidative damage as possible mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Grotto, Denise; Barcelos, Gustavo R.M.; Barbosa, Fernando [Universidade de Sao Paulo, Departamento de Analises Clinicas, Toxicologicas e Bromatologicas, Faculdade de Ciencias Farmaceuticas de Ribeirao Preto, Ribeirao Preto, SP (Brazil); Castro, Michele M. de [Universidade de Sao Paulo, Departamento de Farmacologia, Faculdade de Medicina de Ribeirao Preto, Ribeirao Preto, SP (Brazil); Garcia, Solange C. [Universidade Federal de Santa Maria, Departamento de Analises Clinicas e Toxicologicas, Santa Maria, Rio Grande do Sul (Brazil)

    2009-07-15

    Increased risk of hypertension after methylmercury (MeHg) exposure has been suggested. However, the underlying mechanisms are not well explored. In this paper, we have analyzed whether sub-chronic exposure to MeHg increases systolic blood pressure even at very low levels. In addition, we analyzed if the methylmercury-induced hypertension is associated with a decreased plasmatic nitric oxide levels and with a dysregulation of the activities of the antioxidant enzymes superoxide dismutase (SOD) and catalase (CAT), as well as the levels of MDA and glutathione. For this study, Wistar rats were treated with methylmercury chloride (100 {mu}g/kg per day) or vehicle. Total treatment time was 100 days. Malondialdehyde (MDA) and circulating NOx levels and superoxide dismutase (SOD) and catalase (CAT) activities were determined in plasma, whereas glutathione levels were determined in erythrocytes. Our results show that long-term treatment at a low level of MeHg affected systolic blood pressure, increasing and reducing the levels of plasmatic MDA and NOx, respectively. However, the activity of SOD did not decrease in the MeHg exposed group when compared to the control. We found a negative correlation between plasmatic nitrite/nitrate (NOx) levels and systolic blood pressure (r=-0.67; P=0.001), and a positive correlation between MDA and systolic blood pressure (r=0.61; P=0.03), thus suggesting increased inhibition of NO formation with the increase of hypertension. In conclusion, long-term exposure to a low dose of MeHg increases the systolic pressure and is associated, at least in part, with increased production of ROS as judged by increased production of malondialdehyde and depressed NO availability. (orig.)