WorldWideScience

Sample records for low-power data-acquisition system

  1. A low-power data acquisition system for geomagnetic observatories and variometer stations

    Science.gov (United States)

    Morschhauser, Achim; Haseloff, Jürgen; Bronkalla, Oliver; Müller-Brettschneider, Carsten; Matzka, Jürgen

    2017-09-01

    A modern geomagnetic observatory must provide data of high stability, continuity, and resolution. The INTERMAGNET network has therefore specified quantitative criteria to ensure a high quality standard of geomagnetic observatories. Here, we present a new data acquisition system which was designed to meet these criteria, in particular with respect to 1 Hz data. This system is based on a Raspberry Pi embedded PC and runs a C+ + data acquisition software. As a result, the data acquisition system is modular, cheap, and flexible, and it can be operated in remote areas with limited power supply. In addition, the system is capable of near-real-time data transmission, using a reverse SSH tunnel to work with any network available. The system hardware was successfully tested at the Niemegk observatory for a period of 1 year and subsequently installed at the Tatuoca observatory in Brazil.

  2. A low-power data acquisition system for geomagnetic observatories and variometer stations

    Directory of Open Access Journals (Sweden)

    A. Morschhauser

    2017-09-01

    Full Text Available A modern geomagnetic observatory must provide data of high stability, continuity, and resolution. The INTERMAGNET network has therefore specified quantitative criteria to ensure a high quality standard of geomagnetic observatories. Here, we present a new data acquisition system which was designed to meet these criteria, in particular with respect to 1 Hz data. This system is based on a Raspberry Pi embedded PC and runs a C+ +  data acquisition software. As a result, the data acquisition system is modular, cheap, and flexible, and it can be operated in remote areas with limited power supply. In addition, the system is capable of near-real-time data transmission, using a reverse SSH tunnel to work with any network available. The system hardware was successfully tested at the Niemegk observatory for a period of 1 year and subsequently installed at the Tatuoca observatory in Brazil.

  3. Low power data acquisition unit for autonomous geophysical instrumentation

    Science.gov (United States)

    Prystai, Andrii

    2017-04-01

    The development of an autonomous instrumentation for field research is always a challenge which needs knowledge and application of recent advances in technology and components production. Using this information a super-low power, low-cost, stand-alone GPS time synchronized data acquisition unit was created. It comprises an extended utilization of the microcontroller modules and peripherals and special firmware with flexible PLL parameters. The present report is devoted to a discussion of synchronization mode of data sampling in autonomous field instruments with possibility of GPS random breaks. In the result the achieved sampling timing accuracy is better than ± 60 ns without phase jumps and distortion plus fixed shift depending on the sample rate. The main application of the system is for simultaneous measurement of several channels from magnetic and electric sensors in field conditions for magneto-telluric instruments. First utilization of this system was in the new developed versions of LEMI-026 magnetometer and LEMI-423 field station, where it was applied for digitizing of up to 6 analogue channels with 32-bit resolution in the range ± 2.5V, digital filtration (LPF) and maximum sample rate 4kS/s. It is ready for record in 5 minutes after being turned on. Recently, this system was successfully utilized with the drone-portable magnetometers destined for the search of metallic objects, like UXO, in rural areas, research of engineering underground structure and for mapping ore bodies. The successful tests of drone-portable system were made and tests results are also discussed.

  4. MAST data acquisition system

    International Nuclear Information System (INIS)

    Shibaev, S.; Counsell, G.; Cunningham, G.; Manhood, S.J.; Thomas-Davies, N.; Waterhouse, J.

    2006-01-01

    The data acquisition system of the Mega-Amp Spherical Tokamak (MAST) presently collects up to 400 MB of data in about 3000 data items per shot, and subsequent fast growth is expected. Since the start of MAST operations (in 1999) the system has changed dramatically. Though we continue to use legacy CAMAC hardware, newer VME, PCI, and PXI based sub-systems collect most of the data now. All legacy software has been redesigned and new software has been developed. Last year a major system improvement was made-replacement of the message distribution system. The new message system provides easy connection of any sub-system independently of its platform and serves as a framework for many new applications. A new data acquisition controller provides full control of common sub-systems, central error logging, and data acquisition alarms for the MAST plant. A number of new sub-systems using Linux and Windows OSs on VME, PCI, and PXI platforms have been developed. A new PXI unit has been designed as a base sub-system accommodating any type of data acquisition and control devices. Several web applications for the real-time MAST monitoring and data presentation have been developed

  5. MPS Data Acquisition System

    International Nuclear Information System (INIS)

    Eiseman, S.E.; Miller, W.J.

    1975-01-01

    A description is given of the data acquisition system used with the multiparticle spectrometer facility at Brookhaven. Detailed information is provided on that part of the system which connects the detectors to the data handler; namely, the detector electronics, device controller, and device port optical isolator

  6. Multiprocessor data acquisition system

    International Nuclear Information System (INIS)

    Haumann, J.R.; Crawford, R.K.

    1987-01-01

    A multiprocessor data acquisition system has been built to replace the single processor systems at the Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory. The multiprocessor system was needed to accommodate the higher data rates at IPNS brought about by improvements in the source and changes in instrument configurations. This paper describes the hardware configuration of the system and the method of task sharing and compares results to the single processor system

  7. Seismic data acquisition systems

    International Nuclear Information System (INIS)

    Kolvankar, V.G.; Nadre, V.N.; Rao, D.S.

    1989-01-01

    Details of seismic data acquisition systems developed at the Bhabha Atomic Research Centre, Bombay are reported. The seismic signals acquired belong to different signal bandwidths in the band from 0.02 Hz to 250 Hz. All these acquisition systems are built around a unique technique of recording multichannel data on to a single track of an audio tape and in digital form. Techniques of how these signals in different bands of frequencies were acquired and recorded are described. Method of detecting seismic signals and its performance is also discussed. Seismic signals acquired in different set-ups are illustrated. Time indexing systems for different set-ups and multichannel waveform display systems which form essential part of the data acquisition systems are also discussed. (author). 13 refs., 6 figs., 1 tab

  8. Data Acquisition System

    International Nuclear Information System (INIS)

    Watwood, D.; Beatty, J.

    1991-01-01

    The Data Acquisition System (DAS) is comprised of a Hewlett-Packard (HP) model 9816, Series 200 Computer System with the appropriate software to acquire, control, and archive data from a Data Acquisition/Control Unit, models HP3497A and HP3498A. The primary storage medium is an HP9153 16-megabyte hard disc. The data is backed-up on three floppy discs. One floppy disc drive is contained in the HP9153 chassis; the other two comprise an HP9122 dual disc drive. An HP82906A line printer supplies hard copy backup. A block diagram of the hardware setup is shown. The HP3497A/3498A Data Acquisition/Control Units read each input channel and transmit the raw voltage reading to the HP9816 CPU via the HPIB bus. The HP9816 converts this voltage to the appropriate engineering units using the calibration curves for the sensor being read. The HP9816 archives both the raw and processed data along with the time and the readings were taken to hard and floppy discs. The processed values and reading time are printed on the line printer. This system is designed to accommodate several types of sensors; each type is discussed in the following sections

  9. MDSplus data acquisition system

    International Nuclear Information System (INIS)

    Stillerman, J.A.; Fredian, T.W.; Klare, K.; Manduchi, G.

    1997-01-01

    MDSplus, a tree based, distributed data acquisition system, was developed in collaboration with the ZTH Group at Los Alamos National Lab and the RFX Group at CNR in Padua, Italy. It is currently in use at MIT, RFX in Padua, TCV at EPFL in Lausanne, and KBSI in South Korea. MDSplus is made up of a set of X/motif based tools for data acquisition and display, as well as diagnostic configuration and management. It is based on a hierarchical experiment description which completely describes the data acquisition and analysis tasks and contains the results from these operations. These tools were designed to operate in a distributed, client/server environment with multiple concurrent readers and writers to the data store. While usually used over a Local Area Network, these tools can be used over the Internet to provide access for remote diagnosticians and even machine operators. An interface to a relational database is provided for storage and management of processed data. IDL is used as the primary data analysis and visualization tool. IDL is a registered trademark of Research Systems Inc. copyright 1996 American Institute of Physics

  10. Flexible data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Clout, P N; Ridley, P A [Science Research Council, Daresbury (UK). Daresbury Lab.

    1978-06-01

    A data acquisition system has been developed which enables several independent experiments to be controlled by a 24 K word PDP-11 computer. Significant features of the system are the use of CAMAC, a high level language (RTL/2) and a general-purpose operating system executive which assist the rapid implementation of new experiments. This system has been used successfully for EXAFS and photo-electron spectroscopy experiments. It is intended to provide powerful concurrent data analysis and feedback facilities to the experimenter by on-line connection to the central IBM 370/165 computer.

  11. Data-acquisition systems

    International Nuclear Information System (INIS)

    Cyborski, D.R.; Teh, K.M.

    1995-01-01

    Up to now, DAPHNE, the data-acquisition system developed for ATLAS, was used routinely for experiments at ATLAS and the Dynamitron. More recently, the Division implemented 2 MSU/DAPHNE systems. The MSU/DAPHNE system is a hybrid data-acquisition system which combines the front-end of the Michigan State University (MSU) DA system with the traditional DAPHNE back-end. The MSU front-end is based on commercially available modules. This alleviates the problems encountered with the DAPHNE front-end which is based on custom designed electronics. The first MSU system was obtained for the APEX experiment and was used there successfully. A second MSU front-end, purchased as a backup for the APEX experiment, was installed as a fully-independent second MSU/DAPHNE system with the procurement of a DEC 3000 Alpha host computer, and was used successfully for data-taking in an experiment at ATLAS. Additional hardware for a third system was bought and will be installed. With the availability of 2 MSU/DAPHNE systems in addition to the existing APEX setup, it is planned that the existing DAPHNE front-end will be decommissioned

  12. TCABR data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Fagundes, A.N. E-mail: fagundes@if.usp.br; Sa, W.P.; Coelho, P.M.S.A

    2000-08-01

    A brief description of the design of the data acquisition system for the TCABR tokamak is presented. The system comprises the VME standard instrumentation incorporating CAMAC instrumentation through the use of a GPIB interface. All the necessary data for programming different parts of the equipment, as well as the repertoire of actions for the machine control, are stored in a DBMS, with friendly interfaces. Public access software is used, where feasible, in the development of codes. The TCABR distinguished feature is the virtual lack of frontiers in upgrading, either in hardware or software.

  13. Data Acquisition System

    International Nuclear Information System (INIS)

    Cirstea, C.D.; Buda, S.I.; Constantin, F.

    2005-01-01

    This paper deals with a multi parametric acquisition system developed for a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  14. Data acquisition system

    International Nuclear Information System (INIS)

    Cirstea, D.C.; Buda, S.I.; Constantin, F.

    2005-01-01

    The topic of this paper deals with a multi parametric acquisition system developed around a four input Analog to Digital Converter working in CAMAC Standard. The acquisition software is built in MS Visual C++ on a standard PC with a USB interface. It has a visual interface which permits Start/Stop of the acquisition, setting the type of acquisition (True/Live time), the time and various menus for primary data acquisition. The spectrum is dynamically visualized with a moving cursor indicating the content and position. The microcontroller PIC16C765 is used for data transfer from ADC to PC; The microcontroller and the software create an embedded system which emulates the CAMAC protocol programming, the 4 input ADC for operating modes ('zero suppression', 'addressed' and 'sequential') and handling the data transfers from ADC to its internal memory. From its memory the data is transferred into the PC by the USB interface. The work is in progress. (authors)

  15. IPNS data acquisition system

    International Nuclear Information System (INIS)

    Worlton, T.G.; Crawford, R.K.; Haumann, J.R.; Daly, R.

    1983-01-01

    The IPNS Data Acquisition System (DAS) was designed to be reliable, flexible, and easy to use. It provides unique methods of acquiring Time-of-Flight neutron scattering data and allows collection, storage, display, and analysis of very large data arrays with a minimum of user input. Data can be collected from normal detectors, linear position-sensitive detectors, and/or area detectors. The data can be corrected for time-delays and can be time-focussed before being binned. Corrections to be made to the data and selection of inputs to be summed are entirely software controlled, as are the time ranges and resolutions for each detector element. Each system can be configured to collect data into millions of channels. Maximum continuous data rates are greater than 2000 counts/sec with full corrections, or 16,000 counts/sec for the simpler binning scheme used with area detectors. Live displays of the data may be made as a function of time, wavevector, wavelength, lattice spacing, or energy. In most cases the complete data analysis can be done on the DAS host computer. The IPNS DAS became operational for four neutron scattering instruments in 1981 and has since been expanded to seven instruments

  16. Ref Tek Ultra-low Power Seismic Recorder With Low-cost High Speed Internet Telemetry U An Advanced Real-time Seismological Data Acquisition System

    Science.gov (United States)

    Passmore, P.; Zimakov, L.; Rozhkov, M.

    The 3rd Generation Seismic Recorder, Model 130-01, has been designed to be easier to use - more compact, lighter in weight, lower power, and requires less maintenance than other recorders. Not only is the hardware optimized for field deployments, soft- ware tools as well have been specially developed to support both field and base station operation. The 130's case is a clamshell design, inherently waterproof, with easy access to all user features on the top of the unit. The 130 has 6 input/output connectors, an LCD display, and a removable lid on top of the case. There are two Channel input connectors on a 6-channel unit (only one on a 3-channel unit), a Terminal connector for setup and control, a Net connector combining Ethernet and Serial PPP for network access, a 12 VDC Power connector, and a GPS receiver connector. The LCD display allows the user to monitor the status of various sub systems within the 130 without having a terminal device attached. For storing large amounts of data the IBM MicrodriveTM is offered. User setup, control and status monitoring is done either with a Personal Digital Assistant (PDA) (Palm OS compatible) using our Palm Field Controller (PFC) software or from a PC/workstation using our REF TEK Network Controller (RNC) GUI interface. StarBand VSAT is the premier two-way, always-on, high-speed satellite Internet ser- vice. StarBand means high-speed Internet without the constraints and congestion of land-based cable or telephone networks. StarBand uses a single satellite dish antenna for receiving and for sending dataUno telephone connection is needed. The hardware ° cost is much less than standard VSAT equipment with double or single hop transmis- sion. REF TEK protocol (RTP) provides end-to-end error-correcting data transmission and command/control. StarBandSs low cost VSAT provides two-way, always-on, high speed satellite Internet data availability. REF TEK and StarBand create the most ad- vanced real-time seismological data acquisition

  17. Portable Data Acquisition System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a portable data acquisition system (PDAT) that can be easily transported and set up at remote locations to display and archive...

  18. New KENS data acquisition system

    International Nuclear Information System (INIS)

    Arai, M.; Furusaka, M.; Satoh, S.

    1989-01-01

    In this report, the authors discuss a data acquisition system, KENSnet, which is newly introduced to the KENS facility. The criteria for the data acquisition system was about 1 MIPS for CPU speed and 150 Mbytes for storage capacity for a computer per spectrometer. VAX computers were chosen with their propreitary operating system, VMS. The Vax computers are connected by a DECnet network mediated by Ethernet. Front-end computers, Apple Macintosh Plus and Macintosh II, were chosen for their user-friendly manipulation and intelligence. New CAMAC-based data acquisition electronics were developed. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS and have been installed. 2 refs., 3 figs., 1 tab

  19. KENS data acquisition system KENSnet

    International Nuclear Information System (INIS)

    Arai, Masatoshi; Furusaka, Michihiro; Satoh, Setsuo; Johnson, M.W.

    1988-01-01

    The installation of a new data acquisition system KENSnet has been completed at the KENS neutron facility. For data collection, 160 Mbytes are necessary for temporary disk storage, and 1 MIPS of CPU is required. For the computing system, models were chosen from the VAX family of computers running their proprietary operating system VMS. The VMS operating system has a very user friendly interface, and is well suited to instrument control applications. New data acquisition electronics were developed. A gate module receives a signal of proton extraction time from the accelerator, and checks the veto signals from the sample environment equipment (vacuum, temperature, chopper phasing, etc.). Then the signal is issued to a delay-time module. A time-control module starts timing from the delayed start signal from the delay-time module, and distributes an encoded time-boundary address to memory modules at the preset times anabling the memory modules to accumulate data histograms. The data acquisition control program (ICP) and the general data analysis program (Genie) were both developed at ISIS, and have been installed in the new data acquisition system. They give the experimenter 'user-friendly' data acquisition and a good environment for data manipulation. The ICP controls the DAE and transfers the histogram data into the computers. (N.K.)

  20. Performance Confirmation Data Acquisition System

    International Nuclear Information System (INIS)

    D.W. Markman

    2000-01-01

    The purpose of this analysis is to identify and analyze concepts for the acquisition of data in support of the Performance Confirmation (PC) program at the potential subsurface nuclear waste repository at Yucca Mountain. The scope and primary objectives of this analysis are to: (1) Review the criteria for design as presented in the Performance Confirmation Data Acquisition/Monitoring System Description Document, by way of the Input Transmittal, Performance Confirmation Input Criteria (CRWMS M and O 1999c). (2) Identify and describe existing and potential new trends in data acquisition system software and hardware that would support the PC plan. The data acquisition software and hardware will support the field instruments and equipment that will be installed for the observation and perimeter drift borehole monitoring, and in-situ monitoring within the emplacement drifts. The exhaust air monitoring requirements will be supported by a data communication network interface with the ventilation monitoring system database. (3) Identify the concepts and features that a data acquisition system should have in order to support the PC process and its activities. (4) Based on PC monitoring needs and available technologies, further develop concepts of a potential data acquisition system network in support of the PC program and the Site Recommendation and License Application

  1. The meteorological data acquisition system

    International Nuclear Information System (INIS)

    Bouharrour, S.; Thomas, P.

    1975-07-01

    The 200 m meteorological tower of the Karlsruhe Nuclear Research Center has been equipped with 45 instruments measuring the meteorological parameters near the ground level. Frequent inquiry of the instruments implies data acquisition with on-line data reduction. This task is fulfilled by some peripheral units controlled by a PDP-8/I. This report presents details of the hardware configuration and a short description of the software configuration of the meteorological data acquisition system. The report also serves as an instruction for maintenance and repair work to be carried out at the system. (orig.) [de

  2. Ion implantation data acquisition system

    International Nuclear Information System (INIS)

    Struttmann, D.A.; Anderl, R.A.

    1989-01-01

    This paper describes a data acquisition system developed for hydrogen ion-driven permeation experiments for materials relevant to fusion technology. The system consists of an IMB PC-AT, CAMAC interface to diagnostic instrumentation and custom-developed software (BASIC) to provide time-history information for signals from several instruments including three quadrupole mass spectrometers. 4 refs., 5 figs

  3. Advanced IPNE data acquisition system

    International Nuclear Information System (INIS)

    Duma, M.; Moisa, D.; Petrovici, M.; Berceanu, I.; Ivascu, M.; Pascovici, G.; Simion, V.; Osvath, E.; Bock, R.; Gobbi, A.; Hildebrand, K.D.; Lynen, U.; Mueller, W.F.J.; Beeskow, M.

    1987-05-01

    A complex and flexible data acquisition system has been developed in order to run relative complex experiments in our acceleration system - ALIGATOR. AIDA programme has been carried out on a small PDP - 11/34 computer and is based on a CAMAC hardware. The main hardware and software features are presented. (authors)

  4. Data acquisition systems at Fermilab

    International Nuclear Information System (INIS)

    Votava, M.

    1999-01-01

    Experiments at Fermilab require an ongoing program of development for high speed, distributed data acquisition systems. The physics program at the lab has recently started the operation of a Fixed Target run in which experiments are running the DART[1] data acquisition system. The CDF and D experiments are preparing for the start of the next Collider run in mid 2000. Each will read out on the order of 1 million detector channels. In parallel, future experiments such as BTeV R ampersand D and Minos have already started prototype and test beam work. BTeV in particular has challenging data acquisition system requirements with an input rate of 1500 Gbytes/sec into Level 1 buffers and a logging rate of 200 Mbytes/sec. This paper will present a general overview of these data acquisition systems on three fronts those currently in use, those to be deployed for the Collider Run in 2000, and those proposed for future experiments. It will primarily focus on the CDF and D architectures and tools

  5. Modelling a data acquisition system

    International Nuclear Information System (INIS)

    Green, P.W.

    1986-01-01

    A data acquisition system to be run on a Data General ECLIPSE computer has been completely designed and developed using a VAX 11/780. This required that many of the features of the RDOS operating system be simulated on the VAX. Advantages and disadvantages of this approach are discussed, with particular regard to transportability of the system among different machines/operating systems, and the effect of the approach on various design decisions

  6. Aerial robotic data acquisition system

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Hayes, D.W.; Pendergast, M.M.

    1995-01-01

    A small unmanned aerial vehicle (UAV) equipped with sensors for physical and chemical measurements of remote environments, is described. A miniature helicopter airframe is used as a platform for sensor testing and development. The sensor output is integrated with the flight control system for real-time, interactive, data acquisition and analysis. Pre programmed flight missions will be flown with several sensors to demonstrate the cost-effective surveillance capabilities of this new technology. (author) 10 refs

  7. Data acquisition system for SLD

    International Nuclear Information System (INIS)

    Sherden, D.J.

    1985-05-01

    This paper describes the data acquisition system planned for the SLD detector which is being constructed for use with the SLAC Linear Collider (SLC). An exclusively FASTBUS front-end system is used together with a VAX-based host system. While the volume of data transferred does not challenge the band-width capabilities of FASTBUS, extensive use is made of the parallel processing capabilities allowed by FASTBUS to reduce the data to a size which can be handled by the host system. The low repetition rate of the SLC allows a relatively simple software-based trigger. The principal components and overall architecture of the hardware and software are described

  8. The GRIFFIN data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Garnsworthy, A.B., E-mail: garns@triumf.ca [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Pearson, C.J.; Bishop, D.; Shaw, B.; Smith, J.K.; Bowry, M. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Bildstein, V. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada); Hackman, G. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Garrett, P.E. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada); Linn, Y. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Martin, J.-P. [Department of Physics, Université de Montréal, 2900 Boulevard Edouard-Montpetit, Montréal, QC, Canada H3T 1J4 (Canada); Mills, W.J. [Physical Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Svensson, C.E. [Department of Physics, University of Guelph, 50 Stone Rd E, Guelph, ON, Canada N1G 2W1 (Canada)

    2017-05-01

    Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty better than 0.05% are described. The system has demonstrated the ability to effectively collect signals from High-purity germanium crystals at counting rates up to 50 kHz while maintaining good energy resolution, detection efficiency and spectral quality.

  9. DEAP-3600 Data Acquisition System

    Science.gov (United States)

    Lindner, Thomas

    2015-12-01

    DEAP-3600 is a dark matter experiment using liquid argon to detect Weakly Interacting Massive Particles (WIMPs). The DEAP-3600 Data Acquisition (DAQ) has been built using a combination of commercial and custom electronics, organized using the MIDAS framework. The DAQ system needs to suppress a high rate of background events from 39Ar beta decays. This suppression is implemented using a combination of online firmware and software-based event filtering. We will report on progress commissioning the DAQ system, as well as the development of the web-based user interface.

  10. The FINUDA data acquisition system

    International Nuclear Information System (INIS)

    Cerello, P.; Marcello, S.; Filippini, V.; Fiore, L.; Gianotti, P.; Raimondo, A.

    1996-07-01

    A parallel scalable Data Acquisition System, based on VME, has been developed to be used in the FINUDA experiment, scheduled to run at the DAPHNE machine at Frascati starting from 1997. The acquisition software runs on embedded RTPC 8067 processors using the LynxOS operating system. The readout of event fragments is coordinated by a suitable trigger Supervisor. data read by different controllers are transported via dedicated bus to a Global Event Builder running on a UNIX machine. Commands from and to VME processors are sent via socket based network protocols. The network hardware is presently ethernet, but it can easily changed to optical fiber

  11. Crystal ball data acquisition system

    International Nuclear Information System (INIS)

    Chestnut, R.; Kiesling, C.; Bloom, E.; Bulos, F.; Gaiser, J.; Godfrey, G.; Oreglia, M.; Partridge, R.; Peck, C.; Porter, F.; Aschman, D.; Cavali-Sforza, M.; Coyne, D.; Sadrozinski, H.; Kollmann, W.; Richardson, M.

    1979-01-01

    The data acquisition system for the Crystal Ball project at SLAC is described. A PDP-11/t55 using RSX-11M connected to the SLAC Triplex is the basis of the system. A ''physics pipeline'' allows physicists to write their own equipment-monitoring or physics tasks which require event sampling. As well, an interactive analysis package (MULTI) is in the pipeline. Histogram collection and display on the PDP are implemented using the Triplex histogramming package. Various interactive event displays are also implemented

  12. Data acquisition system for MEGHA

    International Nuclear Information System (INIS)

    Chappell, S.P.G.; Hunt, R.A.; Smith, D.; Rae, W.D.M.; Clarke, N.M.; Freer, M.; Fulton, B.R.; Jagpal, S.S.; Singer, S.M.; Watson, D.L.

    2000-01-01

    A multi-channel data acquisition system has been commissioned for the Charissa 'MEGHA' detector array. It is designed to read multiparameter events where there are many potential channels (320) but where only a fraction of these are active in any typical event. Custom-built pre- and main amplifiers process the amplitude (energy) signal from each detector and the system records both amplitude and time of arrival for each signal within an event. The signal amplitude is converted to time using the standard Wilkinson technique and then combined with its time of arrival into a single time trace. These traces are converted by multi-hit TDCs, which only convert the active channels and thus reduce the processing load. Additional custom-built CAMAC modules organise the TDC output into a suitable form for storage and transmission to a network of processor terminals over standard ethernet. This paper presents a description of the data acquisition system from preamplifier through to final storage in a VME-based system and subsequent distribution to a network of Sun terminals over ethernet. The system performance is illustrated with results from heavy-ion elastic scattering recorded with position sensitive strip detectors

  13. Electric vehicle data acquisition system

    DEFF Research Database (Denmark)

    Svendsen, Mathias; Winther-Jensen, Mads; Pedersen, Anders Bro

    2014-01-01

    and industrial applications, e.g. research in electric vehicle driving patterns, vehicle substitutability analysis and fleet management. The platform is based on a embedded computer running Linux, and features a high level of modularity and flexibility. The system operates independently of the make of the car......, by using the On-board Diagnostic port to identify car model and adapt its software accordingly. By utilizing on-board Global Navigation Satellite System, General Packet Radio Service, accelerometer, gyroscope and magnetometer, the system not only provides valuable data for research in the field of electric......A data acquisition system for electric vehicles is presented. The system connects to the On-board Diagnostic port of newer vehicles, and utilizes the in-vehicle sensor network, as well as auxiliary sensors, to gather data. Data is transmitted continuously to a central database for academic...

  14. The ALICE data acquisition system

    CERN Document Server

    Carena, F; Chapeland, S; Chibante Barroso, V; Costa, F; Dénes, E; Divià, R; Fuchs, U; Grigore, A; Kiss, T; Simonetti, G; Soós, C; Telesca, A; Vande Vyvre, P; Von Haller, B

    2014-01-01

    In this paper we describe the design, the construction, the commissioning and the operation of the Data Acquisition (DAQ) and Experiment Control Systems (ECS) of the ALICE experiment at the CERN Large Hadron Collider (LHC). The DAQ and the ECS are the systems used respectively for the acquisition of all physics data and for the overall control of the experiment. They are two computing systems made of hundreds of PCs and data storage units interconnected via two networks. The collection of experimental data from the detectors is performed by several hundreds of high-speed optical links. We describe in detail the design considerations for these systems handling the extreme data throughput resulting from central lead ions collisions at LHC energy. The implementation of the resulting requirements into hardware (custom optical links and commercial computing equipment), infrastructure (racks, cooling, power distribution, control room), and software led to many innovative solutions which are described together with ...

  15. Data Acquisition for Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodsinsky, Carlos M. (Inventor)

    2014-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.

  16. Modelling of data acquisition systems

    International Nuclear Information System (INIS)

    Buono, S.; Gaponenko, I.; Jones, R.; Mapelli, L.; Mornacchi, G.; Prigent, D.; Sanchez-Corral, E.; Spiwoks, R.; Skiadelli, M.; Ambrosini, G.

    1994-01-01

    The RD13 project was approved in April 1991 for the development of a scalable data taking system suitable to host various LHC studies. One of its goals is to use simulations as a tool for understanding, evaluating, and constructing different configurations of such data acquisition (DAQ) systems. The RD13 project has developed a modelling framework for this purpose. It is based on MODSIM II, an object-oriented, discrete-event simulation language. A library of DAQ components allows to describe a variety of DAQ architectures and different hardware options in a modular and scalable way. A graphical user interface (GUI) is used to do easy configuration, initialization and on-line monitoring of the simulation program. A tracing facility is used to do flexible off-line analysis of a trace file written at run-time

  17. The ALICE data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Carena, F.; Carena, W.; Chapeland, S.; Chibante Barroso, V.; Costa, F. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Dénes, E. [Research Institute for Particle and Nuclear Physics, Wigner Research Center, Budapest (Hungary); Divià, R.; Fuchs, U. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Grigore, A. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Politehnica Univesity of Bucharest, Bucharest (Romania); Kiss, T. [Cerntech Ltd., Budapest (Hungary); Simonetti, G. [Dipartimento Interateneo di Fisica ‘M. Merlin’, Bari (Italy); Soós, C.; Telesca, A.; Vande Vyvre, P. [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland); Haller, B. von, E-mail: bvonhall@cern.ch [European Organization for Nuclear Research (CERN), Geneva 23 (Switzerland)

    2014-03-21

    In this paper we describe the design, the construction, the commissioning and the operation of the Data Acquisition (DAQ) and Experiment Control Systems (ECS) of the ALICE experiment at the CERN Large Hadron Collider (LHC). The DAQ and the ECS are the systems used respectively for the acquisition of all physics data and for the overall control of the experiment. They are two computing systems made of hundreds of PCs and data storage units interconnected via two networks. The collection of experimental data from the detectors is performed by several hundreds of high-speed optical links. We describe in detail the design considerations for these systems handling the extreme data throughput resulting from central lead ions collisions at LHC energy. The implementation of the resulting requirements into hardware (custom optical links and commercial computing equipment), infrastructure (racks, cooling, power distribution, control room), and software led to many innovative solutions which are described together with a presentation of all the major components of the systems, as currently realized. We also report on the performance achieved during the first period of data taking (from 2009 to 2013) often exceeding those specified in the DAQ Technical Design Report.

  18. Data acquisition for sensor systems

    CERN Document Server

    Taylor, H Rosemary

    1997-01-01

    'Data acquisition' is concerned with taking one or more analogue signals and converting them to digital form with sufficient accu­ racy and speed to be ready for processing by a computer. The increasing use of computers makes this an expanding field, and it is important that the conversion process is done correctly because information lost at this stage can never be regained, no matter how good the computation. The old saying - garbage in, garbage out - is very relevant to data acquisition, and so every part of the book contains a discussion of errors: where do they come from, how large are they, and what can be done to reduce them? The book aims to treat the data acquisition process in depth with less detailed chapters on the fundamental principles of measure­ ment, sensors and signal conditioning. There is also a chapter on software packages, which are becoming increasingly popular. This is such a rapidly changing topic that any review of available pro­ grams is bound to be out of date before the book re...

  19. EBT data acquisition and analysis system

    International Nuclear Information System (INIS)

    Burris, R.D.; Greenwood, D.E.; Stanton, J.S.; Geoffroy, K.A.

    1980-10-01

    This document describes the design and implementation of a data acquisition and analysis system for the EBT fusion experiment. The system includes data acquisition on five computers, automatic transmission of that data to a large, central data base, and a powerful data retrieval system. The system is flexible and easy to use, and it provides a fully documented record of the experiments

  20. Data-Acquisition Systems for Fusion Devices

    NARCIS (Netherlands)

    van Haren, P. C.; Oomens, N. A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology

  1. Data Acquisition System On Beta Installation

    International Nuclear Information System (INIS)

    Abtokhi, Ahmad; Nurhanan; Sudarno; Sumarno, Edy

    2000-01-01

    Data acquisition system is needed on every installation. This is important used to monitoring and processing data to get information desired. This system applied to β installation which is facility to carry out experiments on accident condition like as reflooding phenomena in test section. The 16 exp.th channel data acquisition system is drived by ADC 0804 and programme application DELPHI

  2. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  3. A marine meteorological data acquisition system

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Desa, E.; Vithayathil, G.

    A marine meteorological data acquisition system has been developed for long term unattended measurements at remote coastal sites, ocean surface platforms and for use on board research vessels. The system has an open and modular configuration...

  4. The CMD-3 Data Acquisition System

    CERN Document Server

    Kozyrev, A N; Epifanov, D A; Epshteyn, L B; Logashenko, I B; Mikhailov, K Yu; Popov, A S; Ruban, A A; Selivanov, A N; Talyshev, A A; Titov, V M; Yudin, Y V

    2017-01-01

    The specialized data acquisition system designed for CMD-3 detector which is installed at the electron-positron collider VEPP-2000 to the Budker Institute of Nuclear Physics, Novosibirsk, Russia. The structure of electronic hardware and firmware is described.

  5. DABASCO Experiment Data Acquisition and Control System

    International Nuclear Information System (INIS)

    Alberdi Primicia, J.; Artigao Arteaga, A.; Barcala Rieveira, J. M.; Oller Gonzalez, J. C.

    2000-01-01

    DABASCO experiment wants to study the thermohydraulic phenomena produced into the containment area for a severe accident in a nuclear power facility. This document describes the characteristics of the data acquisition and control system used in the experiment. The main elements of the system were a data acquisition board, PCI-MIO-16E-4, and an application written with LaB View. (Author) 5 refs

  6. Multi spectral scaling data acquisition system

    International Nuclear Information System (INIS)

    Behere, Anita; Patil, R.D.; Ghodgaonkar, M.D.; Gopalakrishnan, K.R.

    1997-01-01

    In nuclear spectroscopy applications, it is often desired to acquire data at high rate with high resolution. With the availability of low cost computers, it is possible to make a powerful data acquisition system with minimum hardware and software development, by designing a PC plug-in acquisition board. But in using the PC processor for data acquisition, the PC can not be used as a multitasking node. Keeping this in view, PC plug-in acquisition boards with on-board processor find tremendous applications. Transputer based data acquisition board has been designed which can be configured as a high count rate pulse height MCA or as a Multi Spectral Scaler. Multi Spectral Scaling (MSS) is a new technique, in which multiple spectra are acquired in small time frames and are then analyzed. This paper describes the details of this multi spectral scaling data acquisition system. 2 figs

  7. Platform attitude data acquisition system

    Digital Repository Service at National Institute of Oceanography (India)

    Afzulpurkar, S.

    A system for automatic acquisition of underwater platform attitude data has been designed, developed and tested in the laboratory. This is a micro controller based system interfacing dual axis inclinometer, high-resolution digital compass...

  8. Low power laser generated ultrasound: Signal processing for time domain data acquisition

    International Nuclear Information System (INIS)

    Cleary, A; Thursby, G; McKee, C; Armstrong, I; Culshaw, B; Veres, I; Pierce, S G

    2011-01-01

    The use of low power modulated laser diode systems has previously been established as a suitable method for non-destructive laser generation of ultrasound. Using a quasi-continuous optical excitation amplified by an erbium-doped fibre amplifier (EDFA) allows flexible generation of ultrasonic waves, offering control of further parameters such as the frequency content or signal shape. In addition, pseudo-random binary sequences (PRBS) can be used to improve the detected impulse response. Here we compare two sequences, the m-sequence and the Golay code, and discuss the advantages and practical limits of their application with laser diode based optical excitation of ultrasound.

  9. Data acquisition system for nuclear reactor environment

    International Nuclear Information System (INIS)

    Tiwari, Akash; Tiwari, Railesha; Tiwari, S.S.; Panday, Lokesh; Suri, Nitin; Chouksey, Abhsek; Singh, Sarvesh Kumar; Dwivedi, Tarun; Agrawal, Ashish; Pandey, Pranav Kumar; Sharma, Brijnandan; Bhatia, Chirag

    2004-01-01

    We have designed an online real time data acquisition system for nuclear reactor environment monitoring. Data acquisition system has eight channels of analog signals and one channel of pulsed input signal from detectors like GM Tube, or any other similar input. Connectivity between the data acquisition system and environmental parameters monitoring computer is made through a wireless data communication link of 151 MHz/100 mW RF power and 10 km maximum communication range for remote data telemetry. Sensors used are gamma ionizing radiation sensor made from CsI:Tl scintillator, atmospheric pressure sensor with +/-0.1 mbar precision, temperature sensor with +/-l milli degree Celsius precision, relative humidity with +/-0.1RH precision, pulse counts with +/-1 count in 0-10000 Hz count rate measurement precision and +/-1 count is accumulated count measurement precision. The entire data acquisition system and wireless telemetry system is 9 V battery powered and the device is to be fitted on a wireless controlled mobile robot for scanning the nuclear reactor zone from remote. Wireless video camera has been planned for integration into the existing system on a later date for moving the robotics environmental data acquisition system beyond human vision reach. System development cost is Rs.25 Lacs and has been developed for Department of Atomic Energy, Government of India and Indian Defense use. (author)

  10. Performance confirmation data acquisition system

    International Nuclear Information System (INIS)

    McAffee, D.A.; Raczka, N.T.

    1997-01-01

    As part of the Viability Assessment (VA) work, this QAP-3-9 document presents and evaluates a comprehensive set of viable concepts for collecting Performance Confirmation (PC) related data. The concepts include: monitoring subsurface repository air temperatures, humidity levels and gaseous emissions via the subsurface ventilation systems, and monitoring the repository geo-technical parameters and rock mass from bore-holes located along the perimeter main drifts and throughout a series of human-rated Observation Drifts to be located in a plane 25 meters above the plane of the emplacement drifts. A key element of this document is the development and analysis of a purposed multi-purpose Remote Inspection Gantry that would provide direct, real-time visual, thermal, and radiological monitoring of conditions inside operational emplacement drifts and close-up observations of in-situ Waste Packages. Preliminary finite-element analyses are presented that indicate the technological feasibility of operating an inspection gantry inside the operational emplacement drifts for short inspection missions lasting 2--3 hours. Overall reliability, availability, and maintainability of the PC data collection concepts are discussed. Preliminary concepts for PC data collection network are also provided

  11. Performance confirmation data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    McAffee, D.A.; Raczka, N.T. [Yucca Mountain Project, Las Vegas, NV (United States)

    1997-12-31

    As part of the Viability Assessment (VA) work, this QAP-3-9 document presents and evaluates a comprehensive set of viable concepts for collecting Performance Confirmation (PC) related data. The concepts include: monitoring subsurface repository air temperatures, humidity levels and gaseous emissions via the subsurface ventilation systems, and monitoring the repository geo-technical parameters and rock mass from bore-holes located along the perimeter main drifts and throughout a series of human-rated Observation Drifts to be located in a plane 25 meters above the plane of the emplacement drifts. A key element of this document is the development and analysis of a purposed multi-purpose Remote Inspection Gantry that would provide direct, real-time visual, thermal, and radiological monitoring of conditions inside operational emplacement drifts and close-up observations of in-situ Waste Packages. Preliminary finite-element analyses are presented that indicate the technological feasibility of operating an inspection gantry inside the operational emplacement drifts for short inspection missions lasting 2--3 hours. Overall reliability, availability, and maintainability of the PC data collection concepts are discussed. Preliminary concepts for PC data collection network are also provided.

  12. LAMPF nuclear chemistry data acquisition system

    International Nuclear Information System (INIS)

    Giesler, G.C.

    1983-01-01

    The LAMPF Nuclear Chemistry Data Acquisition System (DAS) is designed to provide both real-time control of data acquisition and facilities for data processing for a large variety of users. It consists of a PDP-11/44 connected to a parallel CAMAC branch highway as well as to a large number of peripherals. The various types of radiation counters and spectrometers and their connections to the system will be described. Also discussed will be the various methods of connection considered and their advantages and disadvantages. The operation of the system from the standpoint of both hardware and software will be described as well as plans for the future

  13. Building blocks for modular data acquisition systems

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, B

    1996-12-31

    The principles of building blocks for modular data acquisition systems by means of the VIC bus are discussed. Real time operating systems based on the VME environment for program development drastically reducing the time needed to develop a working system. 4 figs.

  14. Data acquisition system of the GDL facility

    International Nuclear Information System (INIS)

    Salikova, T.V.

    1992-01-01

    Data acquisition system (DAS) operates in the RSX-IIM environment with the CAMAC system CAMAC driven and CAMAC control processor are used for the CAMAC system operation support. The exchange rate between a problem and the CAMAC module is equal to 100 K worf/c. 14 refs

  15. Data acquisition system for LHCb calorimeter

    International Nuclear Information System (INIS)

    Dai Gang; Gong Guanghua; Shao Beibei

    2007-01-01

    LHCb Calorimeter system is mainly used to identify and measure the energy of the photon, electron, hadron produced by the collision of proton. TELL1 is a common data acquisition platform based on FPGA for LHCb experiment. It is used to adopt custom data acquisition and process method for every detector and provide the data standard for the CPU matrix. This paper provides a novel DAQ and data process model in VHDL for Calorimeter. According to this model. We have built an effective Calorimeter DAQ system, which would be used in LHCb Experiment. (authors)

  16. Draft Automatic Data Acquisition System Plan

    International Nuclear Information System (INIS)

    1987-04-01

    This Automatic Data Acquisition System (ADAS) Plan has been prepared in support of the requirement for detailed site characterization of the Deaf Smith County candidate repository site in salt, and describes the data acquisition system which will be used for unattended data collection from the geotechnical instrumentation installed at the site. Section 1.1 discusses the programmatic background to the plan, Section 1.2 presents the scope and purpose of the plan, and the organization of the document is given in Section 1.3. 31 refs., 34 figs., 8 tabs

  17. Data Acquisition System for Quartz Crystal Microbalances

    Directory of Open Access Journals (Sweden)

    Kleber Romero Felizardo

    2006-02-01

    Full Text Available This work presents a data acquisition system used in a mass sensor: quartz crystal microbalance. This system reads the frequency of this sensor along the time and sends the collected data to the computer through a serial interface.

  18. Data acquisition system for TBR-1

    International Nuclear Information System (INIS)

    Fagundes, A.N.

    1989-07-01

    The data acquisition system of Tokamak TBR-1 has as goal to obtain retrieval signal from diagnostic systems. The final process of storage, register and transfer of the signals is described. The hardware used to convert the signals and its storage and the software developed for the operation are discussed [pt

  19. The Chateau de Cristal data acquisition system

    International Nuclear Information System (INIS)

    Villard, M.M.

    1987-05-01

    This data acquisition system is built on several dedicated data transfer busses: ADC data readout through the FERA bus, parallel data processing in two VME crates. High data rates and selectivities are performed via this acquisition structure and new developed processing units. The system modularity allows various experiments with additional detectors

  20. Optimization of Hierarchical System for Data Acquisition

    Directory of Open Access Journals (Sweden)

    V. Novotny

    2011-04-01

    Full Text Available Television broadcasting over IP networks (IPTV is one of a number of network applications that are except of media distribution also interested in data acquisition from group of information resources of variable size. IP-TV uses Real-time Transport Protocol (RTP protocol for media streaming and RTP Control Protocol (RTCP protocol for session quality feedback. Other applications, for example sensor networks, have data acquisition as the main task. Current solutions have mostly problem with scalability - how to collect and process information from large amount of end nodes quickly and effectively? The article deals with optimization of hierarchical system of data acquisition. Problem is mathematically described, delay minima are searched and results are proved by simulations.

  1. PC based 8-parameter data acquisition system

    International Nuclear Information System (INIS)

    Gupta, J.D.; Naik, K.V.; Jain, S.K.; Pathak, R.V.; Suman, B.

    1989-01-01

    Multiparameter data acquisition (MPA) systems which analyse nuclear events with respect to more than one property of the event are essential tools for the study of some complex nuclear phenomena requiring analysis of time coincident spectra. For better throughput and accuracy each parameter is digitized by its own ADC. A stand alone low cost IBM PC based 8-parameter data acquisition system developed by the authors makes use of Address Recording technique for acquiring data from eight 12 bit ADC's in the PC Memory. Two memory buffers in the PC memory are used in ping-pong fashion so that data acquisition in one bank and dumping of data onto PC disk from the other bank can proceed simultaneously. Data is acquired in the PC memory through DMA mode for realising high throughput and hardware interrupt is used for switching banks for data acquisition. A comprehensive software package developed in Turbo-Pascal offers a set of menu-driven interactive commands to the user for setting-up system parameters and control of the system. The system is to be used with pelletron accelerator. (author). 5 figs

  2. Data Acquisition and Real-Time Systems.

    Science.gov (United States)

    Lawrence, D. E., Ed.; Fenwick, P. M., Ed.

    The first group of papers starts with a tutorial paper which surveys the methods used in data acquisition systems. Other papers in this group describe: (1) some problems involved in the computer acquisition of high-speed randomly-occurring data and the protection of this data from accidental corruption, (2) an input/output bus to allow an IBM…

  3. Precision cryogenic temperature data acquisition system

    International Nuclear Information System (INIS)

    Farah, Y.; Sondericker, J.H.

    1985-01-01

    A Multiplexed Temperature Data Acquisition System with an overall precision of +-25 ppM has been designed using state-of-the-art electronics to accurately read temperature between 2.4 K and 600 K from pre-calibrated transducers such as germanium, silicon diode, thermistor or platinum temperature sensors

  4. Embedded Linux platform for data acquisition systems

    International Nuclear Information System (INIS)

    Patel, Jigneshkumar J.; Reddy, Nagaraj; Kumari, Praveena; Rajpal, Rachana; Pujara, Harshad; Jha, R.; Kalappurakkal, Praveen

    2014-01-01

    Highlights: • The design and the development of data acquisition system on FPGA based reconfigurable hardware platform. • Embedded Linux configuration and compilation for FPGA based systems. • Hardware logic IP core and its Linux device driver development for the external peripheral to interface it with the FPGA based system. - Abstract: This scalable hardware–software system is designed and developed to explore the emerging open standards for data acquisition requirement of Tokamak experiments. To address the future need for a scalable data acquisition and control system for fusion experiments, we have explored the capability of software platform using Open Source Embedded Linux Operating System on a programmable hardware platform such as FPGA. The idea was to identify the platform which can be customizable, flexible and scalable to support the data acquisition system requirements. To do this, we have selected FPGA based reconfigurable and scalable hardware platform to design the system with Embedded Linux based operating system for flexibility in software development and Gigabit Ethernet interface for high speed data transactions. The proposed hardware–software platform using FPGA and Embedded Linux OS offers a single chip solution with processor, peripherals such ADC interface controller, Gigabit Ethernet controller, memory controller amongst other peripherals. The Embedded Linux platform for data acquisition is implemented and tested on a Virtex-5 FXT FPGA ML507 which has PowerPC 440 (PPC440) [2] hard block on FPGA. For this work, we have used the Linux Kernel version 2.6.34 with BSP support for the ML507 platform. It is downloaded from the Xilinx [1] GIT server. Cross-compiler tool chain is created using the Buildroot scripts. The Linux Kernel and Root File System are configured and compiled using the cross-tools to support the hardware platform. The Analog to Digital Converter (ADC) IO module is designed and interfaced with the ML507 through Xilinx

  5. Embedded Linux platform for data acquisition systems

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Jigneshkumar J., E-mail: jjp@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Reddy, Nagaraj, E-mail: nagaraj.reddy@coreel.com [Sandeepani School of Embedded System Design, Bangalore, Karnataka (India); Kumari, Praveena, E-mail: praveena@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Rajpal, Rachana, E-mail: rachana@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Pujara, Harshad, E-mail: pujara@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Jha, R., E-mail: rjha@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat (India); Kalappurakkal, Praveen, E-mail: praveen.k@coreel.com [Sandeepani School of Embedded System Design, Bangalore, Karnataka (India)

    2014-05-15

    Highlights: • The design and the development of data acquisition system on FPGA based reconfigurable hardware platform. • Embedded Linux configuration and compilation for FPGA based systems. • Hardware logic IP core and its Linux device driver development for the external peripheral to interface it with the FPGA based system. - Abstract: This scalable hardware–software system is designed and developed to explore the emerging open standards for data acquisition requirement of Tokamak experiments. To address the future need for a scalable data acquisition and control system for fusion experiments, we have explored the capability of software platform using Open Source Embedded Linux Operating System on a programmable hardware platform such as FPGA. The idea was to identify the platform which can be customizable, flexible and scalable to support the data acquisition system requirements. To do this, we have selected FPGA based reconfigurable and scalable hardware platform to design the system with Embedded Linux based operating system for flexibility in software development and Gigabit Ethernet interface for high speed data transactions. The proposed hardware–software platform using FPGA and Embedded Linux OS offers a single chip solution with processor, peripherals such ADC interface controller, Gigabit Ethernet controller, memory controller amongst other peripherals. The Embedded Linux platform for data acquisition is implemented and tested on a Virtex-5 FXT FPGA ML507 which has PowerPC 440 (PPC440) [2] hard block on FPGA. For this work, we have used the Linux Kernel version 2.6.34 with BSP support for the ML507 platform. It is downloaded from the Xilinx [1] GIT server. Cross-compiler tool chain is created using the Buildroot scripts. The Linux Kernel and Root File System are configured and compiled using the cross-tools to support the hardware platform. The Analog to Digital Converter (ADC) IO module is designed and interfaced with the ML507 through Xilinx

  6. DAISY - the Oslo Cyclotron data acquisition system

    International Nuclear Information System (INIS)

    Ramsoey, T.

    1991-08-01

    The new CACTUS multidetector system for the Oslo Cyclotron consists of 8 particle telescopes, 28 NAI detectors and 2 Ge detectors. Each detector gives rise to one energy parameter and one time parameter. Thus, a total of 80 parameters are present. The counting rate is 100 kByte/s for the highest beam intensities. A new data acquisition system, DAISY, satisfying these demands has been designed. The present report is intended as a complete technical manual for the new system. 24 refs

  7. Neutral particle beam distributed data acquisition system

    International Nuclear Information System (INIS)

    Daly, R.T.; Kraimer, M.R.; Novick, A.H.

    1987-01-01

    A distributed data acquisition system has been designed to support experiments at the Argonne Neutral Particle Beam Accelerator. The system uses a host VAXstation II/GPX computer acting as an experimenter's station linked via Ethernet with multiple MicroVAX IIs and rtVAXs dedicated to acquiring data and controlling hardware at remote sites. This paper describes the hardware design of the system, the applications support software on the host and target computers, and the real-time performance

  8. Data acquisition on a VME/68000 system

    International Nuclear Information System (INIS)

    Aoun, Walid

    1990-01-01

    A data acquisition system for correlated or independent events handling has been designed. This system is based on VME boards and 68000 processors. The software include data taking, on line sort and storage on magnetic tape. A driver has been written under the UNIX operating system for a high graphic resolution VME board, this implementation was provided as an off-line facility. (author) [fr

  9. Data acquisition systems for fusion devices

    International Nuclear Information System (INIS)

    Van Haren, P.C.; Oomens, N.A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology driven; the emphasis has been on the development of computer hardware and system software. For future DASs, challenging problems are to be solved: The DASs have to be better optimized with respect to the needs of the users. Existing bottlenecks, such as CAMAC-computer coupling or pulse file merging, need to be eliminated. Continuous or long-pulse operation will require the introduction of event abstraction in DAS design. 59 refs., 4 figs., 1 tab

  10. Embedded data acquisition system with MDSPlus

    International Nuclear Information System (INIS)

    Rajpal, Rachana; Patel, Jigneshkumar; Kumari, Praveena; Panchal, Vipul; Chattopadhyay, P.K.; Pujara, Harshad; Saxena, Y.C.

    2012-01-01

    This data acquisition system (DAS) is designed and developed to cater the increasing demand of Plasma Diagnostics for Aditya Tokamak as well as to support the basic physics research going on at Institute for Plasma Research. The main design criteria were to design a system with minimum resources and flexible to cater the needs of slow and fast diagnostic channels and can be easily integrated with the existing data acquisition system of Aditya Tokamak. The DAS is designed on embedded PC/104 platform. This is a multi channel system which supports standard features of commercially available DAS. The control and bus interface logic are implemented using Very High Speed Hardware Description Language (VHDL) on Complex Programmable Logic Device (CPLD). For Aditya Tokamak pulse experiment, the software application is designed such that the data is directly integrated to the MDSplus tree of Aditya DAS. The detailed hardware and software design, development and testing results will be discussed in the paper.

  11. Data acquisition and test system software

    International Nuclear Information System (INIS)

    Bourgeois, N.A. Jr.

    1979-03-01

    Sandia Laboratories has been assigned the task by the Base and Installation Security Systems (BISS) Program Office to develop various aspects of perimeter security systems. One part of this effort involves the development of advanced signal processing techniques to reduce the false and nuisance alarms from sensor systems while improving the probability of intrusion detection. The need existed for both data acquisition hardware and software. Also, the hardware is used to implement and test the signal processing algorithms in real time. The hardware developed for this signal processing task is the Data Acquisition and Test System (DATS). The programs developed for use on DATS are described. The descriptions are taken directly from the documentation included within the source programs themselves

  12. Software for nuclear data acquisition systems

    International Nuclear Information System (INIS)

    Christensen, P.

    1983-01-01

    The situation for experimenters and system designers needing software for instrumentation is described. It is stated that software for a data acquisition system can be divided into programmes described as the foundation software, the applications programme, and the analysis programme. Special attention is given to CAMAC. Two examples from Risoe describing data transportation and archiving are given. Finally the supply of software and the problems of documentation are described. (author)

  13. The ngdp framework for data acquisition systems

    OpenAIRE

    Isupov, A. Yu.

    2010-01-01

    The ngdp framework is intended to provide a base for the data acquisition (DAQ) system software. The ngdp's design key features are: high modularity and scalability; usage of the kernel context (particularly kernel threads) of the operating systems (OS), which allows to avoid preemptive scheduling and unnecessary memory--to--memory copying between contexts; elimination of intermediate data storages on the media slower than the operating memory like hard disks, etc. The ngdp, having the above ...

  14. The UA1 VME data acquisition system

    International Nuclear Information System (INIS)

    Cittolin, S.

    1988-01-01

    The data acquisition system of a large-scale experiment such as UA1, running at the CERN proton-antiproton collider, has to cope with very high data rates and to perform sophisticated triggering and filtering in order to analyze interesting events. These functions are performed by a variety of programmable units organized in a parallel multiprocessor system whose central architecture is based on the industry-standard VME/VMXbus. (orig.)

  15. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  16. The BaBar Data Acquisition System

    CERN Document Server

    Scott, I; Grosso, P; Huffer, M E; O'Grady, C; Russell, J J

    1999-01-01

    The BaBar experiment at the Stanford Linear Accelerator Center is designed to perform a search for CP violation by ana-lyzing the decays of a very large sample of B and B(Bar) mesons produced at the high luminosity PEP-II accelerator. The data acquisition system must cope with a sustained high event rate, while supporting real time feature extraction and data compression with minimal dead time. The BaBar data acquisition system is based around a common VME interface to the electronics read-out of the separate detec-tor subsystems. Data from the front end electronics is read into commercial VME processors via a custom "Personality Card" and PCI interface. The commercial CPUs run the Tornado operating system to provide a platform for detector subsystem code to perform the necessary data processing. The data is read out via a non-blocking network switch to a farm of commercial UNIX processors. The current implementation of the BaBar data acquisition sys-tem has been shown to sustain a Level 1 trigger rate of 1.3...

  17. Fast Access Data Acquisition System (FADAS)

    International Nuclear Information System (INIS)

    Katsman, Vladimir

    1998-01-01

    Our goal in this program is to develop Fast Access Data Acquisition System (FADAS) by combining the flexibility of Multilink's GaAs and InP electronics and electro-optics with an extremely high data rate for the efficient handling and transfer of collider experimental data. This novel solution is based on Multilink's and Los Alamos National Laboratory's (LANL) unique components and technologies for extremely fast data transfer, storage, and processing

  18. Development of data acquisition system for CSNS 3He detector

    International Nuclear Information System (INIS)

    Zhao Dongxu; Zhang Hongyu

    2012-01-01

    This paper introduces the research and development of data acquisition system of CSNS 3 He detector prototype. This system provides high performance data acquisition capability of CSNS 3 He detector, as well as several performance tests of electronics prototype. This data acquisition system establishes foundation for the later data acquisition development. (authors)

  19. MPS [Multiparticle Spectrometer] data acquisition software system

    International Nuclear Information System (INIS)

    Saulys, A.C.; Etkin, A.; Foley, K.J.

    1989-01-01

    A description of the software for a FASTBUS based data acquisition system in use at the Brookhaven National Laboratory Multiparticle Spectrometer is presented. Data reading and formatting is done by the SLAC Scanner Processors (SSP's) resident in the FASTBUS system. A multiprocess software system on VAX computers is used to communicate with the SSP's, record the data, and monitor on-line the progress of high energy and heavy ion experiments. The structure and the performance of this system are discussed. 4 refs., 1 fig

  20. On Shaft Data Acquisition System (OSDAS)

    Science.gov (United States)

    Pedings, Marc; DeHart, Shawn; Formby, Jason; Naumann, Charles

    2012-01-01

    On Shaft Data Acquisition System (OSDAS) is a rugged, compact, multiple-channel data acquisition computer system that is designed to record data from instrumentation while operating under extreme rotational centrifugal or gravitational acceleration forces. This system, which was developed for the Heritage Fuel Air Turbine Test (HFATT) program, addresses the problem of recording multiple channels of high-sample-rate data on most any rotating test article by mounting the entire acquisition computer onboard with the turbine test article. With the limited availability of slip ring wires for power and communication, OSDAS utilizes its own resources to provide independent power and amplification for each instrument. Since OSDAS utilizes standard PC technology as well as shared code interfaces with the next-generation, real-time health monitoring system (SPARTAA Scalable Parallel Architecture for Real Time Analysis and Acquisition), this system could be expanded beyond its current capabilities, such as providing advanced health monitoring capabilities for the test article. High-conductor-count slip rings are expensive to purchase and maintain, yet only provide a limited number of conductors for routing instrumentation off the article and to a stationary data acquisition system. In addition to being limited to a small number of instruments, slip rings are prone to wear quickly, and introduce noise and other undesirable characteristics to the signal data. This led to the development of a system capable of recording high-density instrumentation, at high sample rates, on the test article itself, all while under extreme rotational stress. OSDAS is a fully functional PC-based system with 48 channels of 24-bit, high-sample-rate input channels, phase synchronized, with an onboard storage capacity of over 1/2-terabyte of solid-state storage. This recording system takes a novel approach to the problem of recording multiple channels of instrumentation, integrated with the test

  1. The HyperCP data acquisition system

    International Nuclear Information System (INIS)

    Kaplan, D.M.

    1997-06-01

    For the HyperCP experiment at Fermilab, we have assembled a data acquisition system that records on up to 45 Exabyte 8505 tape drives in parallel at up to 17 MB/s. During the beam spill, data are acquired from the front-end digitization systems at ∼ 60 MB/s via five parallel data paths. The front-end systems achieve typical readout deadtime of ∼ 1 micros per event, allowing operation at 75-kHz trigger rate with approx-lt 30% deadtime. Event building and tapewriting are handled by 15 Motorola MVME167 processors in 5 VME crates

  2. The ngdp framework for data acquisition systems

    International Nuclear Information System (INIS)

    Isupov, A.Yu.

    2010-01-01

    The ngdp framework is intended to provide a base for the data acquisition (DAQ) system software. The ngdp's design key features are: high modularity and scalability; usage of the kernel context (particularly kernel threads) of the operating systems (OS), which allows one to avoid preemptive scheduling and unnecessary memory-to-memory copying between contexts; elimination of intermediate data storages on the media slower than the operating memory like hard disks, etc. The ngdp, having the above properties, is suitable to organize and manage data transportation and processing for needs of essentially distributed DAQ systems

  3. CAMAC data acquisition system for the pelletron

    International Nuclear Information System (INIS)

    Chatterjee, A.; Ghodgaonkar, M.D.; Khare, A.N.

    1993-01-01

    We have developed a CAMAC data acquisition system to meet the needs of a broad range of experiments at the pelletron. The system makes use of the DMA CAMAC crate controller CC3. The system is designed around two configurations. In the first, the crate controller is interfaced to an IBM PC/AT. The data are acquired on the PC Winchester disk. In the second configuration, the IBM PC is further linked to a HORIZON III mini-computer via ethernet. In this case list mode data can be taken directly on 1/2-inch reel tapes or 60MB cartridges. (author). 3 refs., 2 figs

  4. Embedded data acquisition system for neutron monitors

    International Nuclear Information System (INIS)

    Población, Ó G; Tejedor, I G; Sánchez, S; Blanco, J J; Gómez-Herrero, R; Medina, J; Steigies, C T

    2014-01-01

    This article presents the design and implementation of a new data acquisition system to be used as replacement for the old ones that have been in use with neutron monitors for the last decades and, which are eventually becoming obsolete. This new system is also intended to be used in new installations, enabling these scientific instruments to use today's communication networks to send data and receive commands from the operators. This system is currently running in two stations: KIEL2, in the Christian-Albrechts-Universität zu Kiel, Kiel, Germany, and CALMA, in the Castilla-La Mancha Neutron Monitor, Guadalajara, Spain

  5. The data acquisition system for SLD

    International Nuclear Information System (INIS)

    Sherden, D.J.

    1986-10-01

    This paper describes the data acquisition system planned for the SLD detector, which is being constructed for use with the SLAC Linear Collider (SLC). Analog electronics, heavily incorporating hybrid and custom VLSI circuitry, is mounted on the detector itself. Extensive use is made of multiplexing through optical fibers to a FASTBUS readout system. The low repetition rate of the SLC allows a relatively simple software-based trigger. Hardware and software processors within the acquisition modules are used to reduce the large volume of data per event and to calibrate the electronics. A farm of microprocessors is used for full reconstruction of a sample of events prior to transmission to the host

  6. Distributed radiation data acquisition system for KAPP

    International Nuclear Information System (INIS)

    Narsaiah, A.; Anantakrishnan, T.S.; Bairi, B.R.

    1992-01-01

    Increased concern for the safety of personnel working in Nuclear Power Stations demands an efficient centralized Radiation Data Acquisition System (RADAS) to monitor different types of radiation at distributed locations of the plant. The system provides a comprehensive picture of radio-activity level distribution in the reactor building to facilitate prompt and correct decision making to take care of any emergency situation. The system is build around an industrial IBM-PC connected to remote intelligent data acquisition units using serial data communication links. To ensure high system availability and ease of maintenance the mechanical moving disk storage has been replaced by solid state memory storage (RAM Disk). Functional CRT displays have been substituted by the assembly of IBM-PC Mother Board with built-in firmware and standard TV Monitor. The computer handles a variety of processing functions which include the conversion to engineering units, checking of alarms, display/printing of plant radiation level status and system diagnostics. Intelligent terminals have been provided with graphic and text formatting capabilities. A hot standby computer connected to analog and digital inputs takes over the system functions on the failure of the host system. Modular software written in the higher level C-language runs under a standard real-time operating system Kernel. This provides for easy modification and expandability at site. Based on the experience of its commissioning at Kakrapar Power Station a new compact version is being designed for a specific application in another class of reactor. (author). 3 refs., 1 fig

  7. Multiparameter data acquisition system for spectroscopy

    International Nuclear Information System (INIS)

    Beiersdorfer, P.; Brown, G. V.; Hildebrandt, L.; Wong, K. L.; Ali, R.

    2001-01-01

    A powerful and versatile, simple to use multiparameter data acquisition system has been implemented for use in spectroscopy. In its standard configuration, the system can acquire signal from 16 time-to-digital converter channels, 16 analog-to-digital converter channels, and 12 scaler inputs. The system was put to use on the electron beam ion trap experiment to record the output from four position-sensitive proportional counters in two soft x-ray spectrometers together with the signal from an x-ray pulse height analyzer. Also recorded are the electron beam energy and the pulse height distribution of the proportional counters. All data are recorded as a function of time. Because the relevant parameters are recorded simultaneously, software gates instead of hardware gates are used to select the data of interest. This has led to a substantial cost saving over earlier data acquisition systems. Data are stored in binary or in ascii format for system-independent processing. The operation of the system is demonstrated in a measurement of the M-shell soft x-ray spectrum of gold. We used the system to record the 3--4 and 3--5 transitions of gold (Au 44+ --Au 51+ ) excited with a simulated Maxwellian with electron temperature of 2.5 keV

  8. Advanced data acquisition system for SEVAN

    Science.gov (United States)

    Chilingaryan, Suren; Chilingarian, Ashot; Danielyan, Varuzhan; Eppler, Wolfgang

    2009-02-01

    Huge magnetic clouds of plasma emitted by the Sun dominate intense geomagnetic storm occurrences and simultaneously they are correlated with variations of spectra of particles and nuclei in the interplanetary space, ranging from subtermal solar wind ions till GeV energy galactic cosmic rays. For a reliable and fast forecast of Space Weather world-wide networks of particle detectors are operated at different latitudes, longitudes, and altitudes. Based on a new type of hybrid particle detector developed in the context of the International Heliophysical Year (IHY 2007) at Aragats Space Environmental Center (ASEC) we start to prepare hardware and software for the first sites of Space Environmental Viewing and Analysis Network (SEVAN). In the paper the architecture of the newly developed data acquisition system for SEVAN is presented. We plan to run the SEVAN network under one-and-the-same data acquisition system, enabling fast integration of data for on-line analysis of Solar Flare Events. An Advanced Data Acquisition System (ADAS) is designed as a distributed network of uniform components connected by Web Services. Its main component is Unified Readout and Control Server (URCS) which controls the underlying electronics by means of detector specific drivers and makes a preliminary analysis of the on-line data. The lower level components of URCS are implemented in C and a fast binary representation is used for the data exchange with electronics. However, after preprocessing, the data are converted to a self-describing hybrid XML/Binary format. To achieve better reliability all URCS are running on embedded computers without disk and fans to avoid the limited lifetime of moving mechanical parts. The data storage is carried out by means of high performance servers working in parallel to provide data security. These servers are periodically inquiring the data from all URCS and storing it in a MySQL database. The implementation of the control interface is based on high level

  9. New data acquisition system for AMS

    Energy Technology Data Exchange (ETDEWEB)

    Pfenninger, R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A new data acquisition system based on a VME front-end computer, a Sun workstation and a PC has been installed. It is used for the acquisition of mainly AMS data, their graphical display, and storage of the data in a Oracle database. The measurement of magazines of 25 sample each is fully automated. Several data parameters such as transmission are regularly checked. In case of problems the operator is informed by optical and/or acoustical signals. Screens are updated automatically after every measurement cycle. (author) 1 fig.

  10. Isothermal thermogravimetric data acquisition analysis system

    Science.gov (United States)

    Cooper, Kenneth, Jr.

    1991-01-01

    The description of an Isothermal Thermogravimetric Analysis (TGA) Data Acquisition System is presented. The system consists of software and hardware to perform a wide variety of TGA experiments. The software is written in ANSI C using Borland's Turbo C++. The hardware consists of a 486/25 MHz machine with a Capital Equipment Corp. IEEE488 interface card. The interface is to a Hewlett Packard 3497A data acquisition system using two analog input cards and a digital actuator card. The system provides for 16 TGA rigs with weight and temperature measurements from each rig. Data collection is conducted in three phases. Acquisition is done at a rapid rate during initial startup, at a slower rate during extended data collection periods, and finally at a fast rate during shutdown. Parameters controlling the rate and duration of each phase are user programmable. Furnace control (raising and lowering) is also programmable. Provision is made for automatic restart in the event of power failure or other abnormal terminations. Initial trial runs were conducted to show system stability.

  11. Jefferson Lab Data Acquisition Run Control System

    International Nuclear Information System (INIS)

    Vardan Gyurjyan; Carl Timmer; David Abbott; William Heyes; Edward Jastrzembski; David Lawrence; Elliott Wolin

    2004-01-01

    A general overview of the Jefferson Lab data acquisition run control system is presented. This run control system is designed to operate the configuration, control, and monitoring of all Jefferson Lab experiments. It controls data-taking activities by coordinating the operation of DAQ sub-systems, online software components and third-party software such as external slow control systems. The main, unique feature which sets this system apart from conventional systems is its incorporation of intelligent agent concepts. Intelligent agents are autonomous programs which interact with each other through certain protocols on a peer-to-peer level. In this case, the protocols and standards used come from the domain-independent Foundation for Intelligent Physical Agents (FIPA), and the implementation used is the Java Agent Development Framework (JADE). A lightweight, XML/RDF-based language was developed to standardize the description of the run control system for configuration purposes

  12. The DISTO data acquisition system at SATURNE

    International Nuclear Information System (INIS)

    Balestra, F.; Bedfer, Y.; Bertini, R.

    1998-01-01

    The DISTO collaboration has built a large-acceptance magnetic spectrometer designed to provide broad kinematic coverage of multiparticle final states produced in pp scattering. The spectrometer has been installed in the polarized proton beam of the Saturne accelerator in Saclay to study polarization observables in the rvec pp → pK + rvec Y (Y = Λ, Σ 0 or Y * ) reaction and vector meson production (ψ, ω and ρ) in pp collisions. The data acquisition system is based on a VME 68030 CPU running the OS/9 operating system, housed in a single VME crate together with the CAMAC interface, the triple port ECL memories, and four RISC R3000 CPU. The digitization of signals from the detectors is made by PCOS III and FERA front-end electronics. Data of several events belonging to a single Saturne extraction are stored in VME triple-port ECL memories using a hardwired fast sequencer. The buffer, optionally filtered by the RISC R3000 CPU, is recorded on a DLT cassette by DAQ CPU using the on-board SCSI interface during the acceleration cycle. Two UNIX workstations are connected to the VME CPUs through a fast parallel bus and the Local Area Network. They analyze a subset of events for on-line monitoring. The data acquisition system is able to read and record 3,500 ev/burst in the present configuration with a dead time of 15%

  13. Modeling of the DZero data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Angstadt, R.; Johnson, M.; Manning, I.L. [Fermi National Accelerator Lab., Batavia, IL (United States); Wightman, J.A. [Texas A and M Univ., College Station, TX (United States). Dept. of Physics]|[Texas Accelerator Center, The Woodlands, TX (United States)

    1991-12-01

    A queuing theory model was used in the initial design of the D0 data acquisition system. It was mainly used for the front end electronic systems. Since then the model has been extended to include the entire data path for the tracking system. The tracking system generates the most data so we expect this system to determine the overall transfer rate. The model was developed using both analytical and simulation methods for solving a series of single server queues. We describe the model and the methods used to develop it. We also present results from the original models, updated calculations representing the system as built and comparisons with measurements made with the hardware in place for the cosmic ray test run. 3 refs.

  14. MFTF plasma diagnostics data acquisition system

    International Nuclear Information System (INIS)

    Davis, G.E.; Coffield, F.E.

    1979-01-01

    The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982

  15. Multichannel long period seismic data acquisition system

    International Nuclear Information System (INIS)

    Kolvankar, V.G.; Rao, D.S.

    1990-01-01

    This paper discusses the specifications and performance of an eight channel long period seismic digital data acquisition system, which is developed and installed at Seismic Array Station, Gauribidanur, Karnataka State. The paper describes how these data in an unedited form are recorded on a single track of magnetic tape inter-mittantly, which has resulted in recording of 50 days data on a single tapespool. A time indexing technique which enables quick access to any desired portion of a recorded tape is also discussed. Typical examples of long period seismic event signals recorded by this system are also illustrated. Various advantages, the system provides over the analog multichannel instrumentation tape recording system, operating at Seismic Array Station for th e last two decades, are also discussed. (author). 7 figs

  16. A Data Acquisition System for Medical Imaging

    International Nuclear Information System (INIS)

    Abellan, Carlos; Cachemiche, Jean-Pierre; Rethore, Frederic; Morel, Christian

    2013-06-01

    A data acquisition system for medical imaging applications is presented. Developed at CPPM, it provides high performance generic data acquisition and processing capabilities. The DAQ system is based on the PICMG xTCA standard and is composed of 1 up to 10 cards in a single rack, each one with 2 Altera Stratix IV FPGAs and a Fast Mezzanine Connector (FMC). Several mezzanines have been produced, each one with different functionalities. Some examples are: a mezzanine capable of receiving 36 optical fibres with up to 180 Gbps sustained data rates or a mezzanine with 12 x 5 Gbps input links, 12 x 5 Gbps output links and an SFP+ connector for control purposes. Several rack sizes are also available, thus making the system scalable from a one card desktop system useful for development purpose up to a full featured rack mounted DAQ for high end applications. Depending on the application, boards may exchange data at speeds of up to 25.6 Gbps bidirectional sustained rates in a double star topology through back-plane connections. Also, front panel optical fibres can be used when higher rates are required by the application. The system may be controlled by a standard Ethernet connection, thus providing easy integration with control computers and avoiding the need for drivers. Two control systems are foreseen. A Socket connection provides easy interaction with automation software regardless of the operating system used for the control PC. Moreover a web server may run on the Envision cards and provide an easy intuitive user interface. The system and its different components will be introduced. Some preliminary measurements with high speed signal links will be presented as well as the signal conditioning used to allow these rates. (authors)

  17. Instrumentation & Data Acquisition System (D AS) Engineer

    Science.gov (United States)

    Jackson, Markus Deon

    2015-01-01

    The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

  18. 2XIIB computer data acquisition system

    International Nuclear Information System (INIS)

    Tyler, G.C.

    1975-01-01

    All major plasma diagnostic measurements from the 2XIIB experiment are recorded, digitized, and stored by the computer data acquisition system. The raw data is then examined, correlated, reduced, and useful portions are quickly retrieved which direct the future conduct of the plasma experiment. This is done in real time and on line while the data is current. The immediate availability of this pertinent data has accelerated the rate at which the 2XII personnel have been able to gain knowledge in the study of plasma containment and fusion interaction. The up time of the experiment is being used much more effectively than ever before. This paper describes the hardware configuration of our data system in relation to various plasma parameters measured, the advantages of powerful software routines to reduce and correlate the data, the present plans for expansion of the system, and the problems we have had to overcome in certain areas to meet our original goals

  19. The data acquisition system of ICT

    International Nuclear Information System (INIS)

    Gao Fuqiang; An Kang; Lu Hua; Cao Peng; Jiang Renqing; Gao Fubing

    2008-01-01

    The purpose of the design is to develop a data acquisition system which can be used to collect and transmit hundreds of channels of weak light signal data at the same time, so as to meet the need of industrial computer tomography. The system is composed of two parts, detection circuit and acquisition circuit. FPGA and 20 bit integral and conversion chips are the primary chips adopted in detection circuit, while the primary chips for acquisition circuit are FPGA and AMCCS5335. The problems, data jam-up and data drop were solved by using multilevel memorizer. A large number of experiments have proved that this system has very high precision and transmission reliability. The design has been applied in several industrial computer tomography machines produced by the industrial computer tomography research center of Chongqing University, and its effectiveness is well apprised. (authors)

  20. Microcomputer-controlled ultrasonic data acquisition system

    International Nuclear Information System (INIS)

    Simpson, W.A. Jr.

    1978-11-01

    The large volume of ultrasonic data generated by computer-aided test procedures has necessitated the development of a mobile, high-speed data acquisition and storage system. This approach offers the decided advantage of on-site data collection and remote data processing. It also utilizes standard, commercially available ultrasonic instrumentation. This system is controlled by an Intel 8080A microprocessor. The MCS80-SDK microcomputer board was chosen, and magnetic tape is used as the storage medium. A detailed description is provided of both the hardware and software developed to interface the magnetic tape storage subsystem to Biomation 8100 and Biomation 805 waveform recorders. A boxcar integrator acquisition system is also described for use when signal averaging becomes necessary. Both assembly language and machine language listings are provided for the software

  1. Implementation of High Speed Distributed Data Acquisition System

    Science.gov (United States)

    Raju, Anju P.; Sekhar, Ambika

    2012-09-01

    This paper introduces a high speed distributed data acquisition system based on a field programmable gate array (FPGA). The aim is to develop a "distributed" data acquisition interface. The development of instruments such as personal computers and engineering workstations based on "standard" platforms is the motivation behind this effort. Using standard platforms as the controlling unit allows independence in hardware from a particular vendor and hardware platform. The distributed approach also has advantages from a functional point of view: acquisition resources become available to multiple instruments; the acquisition front-end can be physically remote from the rest of the instrument. High speed data acquisition system transmits data faster to a remote computer system through Ethernet interface. The data is acquired through 16 analog input channels. The input data commands are multiplexed and digitized and then the data is stored in 1K buffer for each input channel. The main control unit in this design is the 16 bit processor implemented in the FPGA. This 16 bit processor is used to set up and initialize the data source and the Ethernet controller, as well as control the flow of data from the memory element to the NIC. Using this processor we can initialize and control the different configuration registers in the Ethernet controller in a easy manner. Then these data packets are sending to the remote PC through the Ethernet interface. The main advantages of the using FPGA as standard platform are its flexibility, low power consumption, short design duration, fast time to market, programmability and high density. The main advantages of using Ethernet controller AX88796 over others are its non PCI interface, the presence of embedded SRAM where transmit and reception buffers are located and high-performance SRAM-like interface. The paper introduces the implementation of the distributed data acquisition using FPGA by VHDL. The main advantages of this system are high

  2. Nike Facility Diagnostics and Data Acquisition System

    Science.gov (United States)

    Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim

    2013-10-01

    The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.

  3. Pattern-based framework for data acquisition systems

    International Nuclear Information System (INIS)

    Padmini, S.; Diwakar, M.P.; Nair, Preetha; Mathew, R.

    2004-01-01

    The data acquisition framework implements a reusable abstract architectural design for use in the development of data acquisition systems. The framework is being used to build Flux Mapping system (FMs) for TAPS III-IV and RRS Data Acquisition System for Dhruva reactor

  4. A prototype switched Ethernet data acquisition system

    International Nuclear Information System (INIS)

    Ye Gaoying; Deng Huichen; Chen Liaoyuan; Liu Li; Wang Xinhui

    1999-01-01

    A prototype switched Ethernet data acquisition system has been built up and successfully operated in HL-1M tokamak experiments. The system is based on a switched high bandwidth Ethernet network with which the CAMAC crates are directly interfaced. It takes the advanced features of LAN switch and Ethernet CAMAC controller (ECC 1365 MK III, HYTEC product) to avoid the rewriting of CAMAC driver for an individual computer system and to ensure high data transmission rate between CAMAC system and host computers on the network. It is a new approach to DAS system architecture and provides a solution for a well-known bottleneck problem in traditional distributed DAS system for fusion research. An average throughput of the test system reaches over 100 Mbps. The system features also an easy and low cost migration from traditional distributed DAS system. In the paper, the hardware configuration, software structure, performance of the system and the method of migrating from current DAS system are discussed in detail. (orig.)

  5. Remote data acquisition system based on MSM7512B8

    International Nuclear Information System (INIS)

    Jiang Junfeng

    2003-01-01

    This paper introduces a remote data acquisition system based on MC68HC908GP32 and MSM7512B, which can accomplish remote data communications on telephone network, and realize remote data acquisition. (authors)

  6. AZ-101 Mixer Pump Demonstration Data Acquisition System and Gamma Cart Data Acquisition Control System Software Configuration Management Plan

    International Nuclear Information System (INIS)

    WHITE, D.A.

    1999-01-01

    This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS)

  7. CODA: A scalable, distributed data acquisition system

    International Nuclear Information System (INIS)

    Watson, W.A. III; Chen, J.; Heyes, G.; Jastrzembski, E.; Quarrie, D.

    1994-01-01

    A new data acquisition system has been designed for physics experiments scheduled to run at CEBAF starting in the summer of 1994. This system runs on Unix workstations connected via ethernet, FDDI, or other network hardware to multiple intelligent front end crates -- VME, CAMAC or FASTBUS. CAMAC crates may either contain intelligent processors, or may be interfaced to VME. The system is modular and scalable, from a single front end crate and one workstation linked by ethernet, to as may as 32 clusters of front end crates ultimately connected via a high speed network to a set of analysis workstations. The system includes an extensible, device independent slow controls package with drivers for CAMAC, VME, and high voltage crates, as well as a link to CEBAF accelerator controls. All distributed processes are managed by standard remote procedure calls propagating change-of-state requests, or reading and writing program variables. Custom components may be easily integrated. The system is portable to any front end processor running the VxWorks real-time kernel, and to most workstations supplying a few standard facilities such as rsh and X-windows, and Motif and socket libraries. Sample implementations exist for 2 Unix workstation families connected via ethernet or FDDI to VME (with interfaces to FASTBUS or CAMAC), and via ethernet to FASTBUS or CAMAC

  8. Automated system for data acquisition and monitoring

    Directory of Open Access Journals (Sweden)

    Borza Sorin

    2017-01-01

    Full Text Available The Environmental management has become, with the development of human society a very important issue. There have been multiple systems that automatically monitors the environment. In this paper we propose a system that integrates GIS software and data acquisition software. In addition the proposed system implements new AHP multicriteria method that can get an answer online on each pollutant influence on limited geographical area in which the monitors. Factors pollutants of limited geographical areas are taken automatically by specific sensors through acquisition board. Labview software, with virtual instrument created by transferring them into a database Access. Access database they are taken up by software Geomedia Professional and processed using multi-criteria method AHP, so that at any moment, their influence on the environment and classify these influences, can be plotted on the screen monitoring system. The system allows, the automatic collection of data, the memorization and the generation of GIS elements. The research presented in this paper were aimed at implementing multi-criteria methods in GIS software.

  9. The WASA Data Acquisition System (WDAQ)

    CERN Document Server

    Gustafsson, L; Sukhanov, A

    1999-01-01

    The WASA Data Acquisition System (WDAQ) is described. It is a modular, and scalable network based system. The chosen structure facilitate that different old and new front-end electronics standards can work together in an efficient way. Fast hardware triggers are created from discriminated signals from specific parts of the WASA detector by extensive use of programmable logic. The trigger logic is configured to do cluster finding in one or two dimensions. The front- end data is linked together in an event-building switch using the Asynchronous Transfer Mode (ATM) protocol and sent to different PC- stations for further filtering, before put onto tape. The data analysis software is using the ROOT (CERN) system which provides a set of object oriented frameworks with all the functionality needed to handle and analyze large amounts of data in a very efficient way. The slow control software is based on the MIDAS (PSI/TRIUMF) system and comprises a fast online database to keep and monitor all WDAQ parameters. The WAS...

  10. Data acquisition system for radiographic imaging

    International Nuclear Information System (INIS)

    Lanza, R.C.; Votano, J.R.; Russ, T.

    1992-01-01

    This patent describes a continuous data acquisition system for radiographic imaging without interrupting acquisition activity the acquisition system. It comprises at least two memory means for storing radiographic data from a radiation detector wherein each of the memory means having a plurality of addressable memory locations and each of the memory means are such that the locations of the memory means correspond to spatial locations in the radiation detector; logic control means for sensing radiographic data transmitted by the radiation detector, for selecting one of the memory means for storage of the data, for transferring data to the selected memory means, and for switching form one memory means to another memory means according to a predefined schedule and according to memory capacity level, the logic control means further comprising a logic device which receives data and increments the contents of locations in a memory means in response to such data; and interface control means for reading data from one or the other memory means when such memory means is not actively acquiring data such that data can be acquired continuously by the system

  11. MIDAS [Master Information and Data Acquisition System

    International Nuclear Information System (INIS)

    Ball, D.L.

    1986-01-01

    The Master Information and Data Acquisition System (MIDAS) is a computerized work control system that provides 24-hour, real-time access to plant equipment information and work package status. It is used in the 400 Area of the Department of Energy (DOE) Hanford Site in Richland, Washington. MIDAS was originally created to aid in the release and control of work at the Fast Flux Test Facility (FFTF), which is operated by the Westinghouse Hanford Company for the DOE. After MIDAS performed that function at FFTF successfully for over two years, its role was expanded to provide similar functions for other facilities supporting the LMR mission. Through its ability to provide online, accurate information on plant components, safety criteria, and work package status, MIDAS reinforces Operations functions and the control and authorization of maintenance activities in the FFTF plant and in other related facilities. Thus, MIDAS enhances the operational safety, as well as the planning and scheduling process for these facilities. MIDAS consists of three parts: The Plant Tracking System (PTS), the Work Control Log (WCL), and the MIDAS Component Indices

  12. The LHCb trigger and data acquisition system

    CERN Document Server

    Dufey, J P; Harris, F; Harvey, J; Jost, B; Mato, P; Müller, E

    2000-01-01

    The LHCb experiment is the most recently approved of the 4 experiments under construction at CERNs LHC accelerator. It is a special purpose experiment designed to precisely measure the CP violation parameters in the B-B system. Triggering poses special problems since the interesting events containing B-mesons are immersed in a large background of inelastic p-p reactions. We therefore decided to implement a 4 level triggering scheme. The LHCb Data Acquisition (DAQ) system will have to cope with an average trigger rate of ~40 kHz, after two levels of hardware triggers, and an average event size of ~100 kB. Thus an event-building network which can sustain an average bandwidth of 4 GB/s is required. A powerful software trigger farm will have to be installed to reduce the rate from the 40 kHz to ~100 Hz of events written to permanent storage. In this paper we outline the general architecture of the Trigger and DAQ system and the readout protocols we plan to implement. First results of simulations of the behavior o...

  13. Data acquisition system issues for large experiments

    International Nuclear Information System (INIS)

    Siskind, E.J.

    2007-01-01

    This talk consists of personal observations on two classes of data acquisition ('DAQ') systems for Silicon trackers in large experiments with which the author has been concerned over the last three or more years. The first half is a classic 'lessons learned' recital based on experience with the high-level debug and configuration of the DAQ system for the GLAST LAT detector. The second half is concerned with a discussion of the promises and pitfalls of using modern (and future) generations of 'system-on-a-chip' ('SOC') or 'platform' field-programmable gate arrays ('FPGAs') in future large DAQ systems. The DAQ system pipeline for the 864k channels of Si tracker in the GLAST LAT consists of five tiers of hardware buffers which ultimately feed into the main memory of the (two-active-node) level-3 trigger processor farm. The data formats and buffer volumes of these tiers are briefly described, as well as the flow control employed between successive tiers. Lessons learned regarding data formats, buffer volumes, and flow control/data discard policy are discussed. The continued development of platform FPGAs containing large amounts of configurable logic fabric, embedded PowerPC hard processor cores, digital signal processing components, large volumes of on-chip buffer memory, and multi-gigabit serial I/O capability permits DAQ system designers to vastly increase the amount of data preprocessing that can be performed in parallel within the DAQ pipeline for detector systems in large experiments. The capabilities of some currently available FPGA families are reviewed, along with the prospects for next-generation families of announced, but not yet available, platform FPGAs. Some experience with an actual implementation is presented, and reconciliation between advertised and achievable specifications is attempted. The prospects for applying these components to space-borne Si tracker detectors are briefly discussed

  14. Data-acquisition system for radon monitoring

    International Nuclear Information System (INIS)

    Franklin, J.C.; Zawadzki, R.J.; Meyer, T.O.; Hill, A.L.

    1976-01-01

    A data-acquisition system was designed by the Bureau of Mines to monitor five detectors with radon continuously flowing through each. These detectors could be monitored up to 12 times an hour, but were only monitored according to a preset time, thus allowing radon to be monitored continuously in a uranium mine. The counter can be set to monitor each detector for any period of time up to 16.5 minutes. This allows very low concentrations to be monitored longer to reduce statistical error. There would be no upper limit in radon concentration that could be monitored, but there would be a lower limit of 50 pCi/l. Each detector was calibrated by the Lucas flask method. Multiple samples were taken at two different concentrations, and the correction factor for each detector was determined by a least squares fit of the data. To verify the calibrations, a series of measurements at several concentrations were made against a constant source. The agreement at low radon concentrations (300 pCi/l) with the two-filter method was within 3 percent; thus, the total error would be this difference plus the two-filter error. At high concentrations, the coefficient of variation ranged between 2.1 and 9.8 percent for the five different detector units

  15. Dumand-array data-acquisition system

    International Nuclear Information System (INIS)

    Brenner, A.E.; Theriot, D.; Dau, W.D.; Geelhood, B.D.; Harris, F.; Learned, J.G.; Stenger, V.; March, R.; Roos, C.; Shumard, E.

    1982-04-01

    An overall data acquisition approach for DUMAND is described. The scheme assumes one array to shore optical fiber transmission line for each string of the array. The basic event sampling period is approx. 13 μsec. All potentially interesting data is transmitted to shore where the major processing is performed

  16. 'RADAR': Euratom's standard unattended data acquisition system

    International Nuclear Information System (INIS)

    Schwalbach, P.; Holzleitner, L.; Jung, S.; Chare, P.; Smejkal, A.; Swinhoe, M.; Kloeckner, W.

    2001-01-01

    Full text: The physical verification of nuclear material is an essential part of Euratom's inspection activities. Industrial plants handling large amounts of bulk material typically require large numbers of measurements. Modem plants, particularly plutonium-handling facilities, are normally automated and make it difficult for the inspector to access the material. Adapting to the plant requirements with respect to safety and security as well as economics (throughput), safeguards instrumentation is today often integrated into the plant. In order to optimize scarce inspection resources, the required measurements as well as the data analysis have to be done automatically as far as feasible. For automatic measurements Euratom has developed a new unattended data acquisition system, called RADAR (Remote Acquisition of Data and Review), which has been deployed to more than a dozen installations, handling more than 100 sensors (neutron and gamma radiations detectors, balances, seals, identity readers, switches, etc.). RADAR is the standard choice for new systems but is also replacing older automatic data systems slowly as they become outdated. RADAR and most of the associated analysis tools are the result of an in-house development, with the support of external software contractors where appropriate. Experience with turn-key systems led, in 1997, to the conclusion that in-house development would be a more effective use of resources than to buy third party products. RADAR has several layers, which will be discussed in detail in the presentation. The inner core of the package consists of services running under Windows NT. This core has watchdog and logging functions, contains a scheduler and takes care of replicating files across a network. Message and file exchange is based on TCP/IP. The replicator service contains compression and encryption facilities, the encryption is based on POP. With the help of routers, e.g. from CISCO, network connections to remote locations can be

  17. Electro-Optical Data Acquisition and Tracking System

    Data.gov (United States)

    Federal Laboratory Consortium — The Electro-Optical Data Acquisition and Tracking System (EDATS) dynamically tracks and measures target signatures. It consists of an instrumentation van integrated...

  18. A data acquisition system based on a personal computer

    International Nuclear Information System (INIS)

    Omata, K.; Fujita, Y.; Yoshikawa, N.; Sekiguchi, M.; Shida, Y.

    1991-07-01

    A versatile and flexible data acquisition system KODAQ (Kakuken Online Data AcQuisition system) has been developed. The system runs with CAMAC and a most popular Japanese personal computer, PC9801 (NEC), similar to the IBM PC/AT. The system is designed to set up easily a data acquisition system for various kinds of nuclear-physics experiments. (author)

  19. Real-Time Wireless Data Acquisition System

    Science.gov (United States)

    Valencia, Emilio J.; Perotti, Jose; Lucena, Angel; Mata, Carlos

    2007-01-01

    Current and future aerospace requirements demand the creation of a new breed of sensing devices, with emphasis on reduced weight, power consumption, and physical size. This new generation of sensors must possess a high degree of intelligence to provide critical data efficiently and in real-time. Intelligence will include self-calibration, self-health assessment, and pre-processing of raw data at the sensor level. Most of these features are already incorporated in the Wireless Sensors Network (SensorNet(TradeMark)), developed by the Instrumentation Group at Kennedy Space Center (KSC). A system based on the SensorNet(TradeMark) architecture consists of data collection point(s) called Central Stations (CS) and intelligent sensors called Remote Stations (RS) where one or more CSs can be accommodated depending on the specific application. The CS's major function is to establish communications with the Remote Stations and to poll each RS for data and health information. The CS also collects, stores and distributes these data to the appropriate systems requiring the information. The system has the ability to perform point-to-point, multi-point and relay mode communications with an autonomous self-diagnosis of each communications link. Upon detection of a communication failure, the system automatically reconfigures to establish new communication paths. These communication paths are automatically and autonomously selected as the best paths by the system based on the existing operating environment. The data acquisition system currently under development at KSC consists of the SensorNet(TradeMark) wireless sensors as the remote stations and the central station called the Radio Frequency Health Node (RFHN). The RFF1N is the central station which remotely communicates with the SensorNet(TradeMark) sensors to control them and to receive data. The system's salient feature is the ability to provide deterministic sensor data with accurate time stamps for both time critical and non

  20. Nuclear spectrometry data acquisition system based on LabVIEW

    International Nuclear Information System (INIS)

    Zhao Dan; Shen Li; Deng Lili; Zhou Sichun

    2006-01-01

    The whole process of designing nuclear spectrometry data acquisition system was particularized with LabVIEW and data acquisition board, based on virtual instrument technology. It can analyze the output of the radiation detector and give the height spectrum by the method of the continuous real-time data acquisition and the abstraction of pulse signal amplitude. The simple test shows that this system can meet the demand, and it can be easily expanded according to the situation. (authors)

  1. Multi-channel data acquisition system for CT

    International Nuclear Information System (INIS)

    Cao Fuqiang; He Bin; Liu Guohua; Xu Minjian

    2009-01-01

    The architecture design and realization of a data acquisition system for multi-channel CT is described. The article introduces the conversion of analog signal to digital signal, the data cache and transmission. This data acquisition system can be widely used in the system which requires the multi-channel, weak current signal detection. (authors)

  2. A data acquisition system based on PC-CAMAC BUS

    International Nuclear Information System (INIS)

    Xie Xiangyang; Jiang Haiyan; Luo Jiarong; Ji Zhenshan

    2000-08-01

    The author introduces a Data Acquisition System applied to HT-7 (a superconduction Tokamak device). The system is based on the CAMAC standard and the personal computer. The software has been written in C language. The system performs the following tasks: setup parameters of modules, data acquisition, disk data storage and their display

  3. Design of the data acquisition and analysis system for RFX

    International Nuclear Information System (INIS)

    Flor, G.

    1986-01-01

    This paper describes the conceptual design of the data acquisition and analysis system for the RFX experiment. In order to adequately describe an intrinsically dynamic experiment, the concept of an experiment's model is introduced. The model is generated by means of a suitable experiment description language; the diagnostic system is represented as a tree structure and is described by defining all the data and devices involved in the data acquisition system. The resulting data structures drive the data acquisition process and can be used, with minor modifications, as data descriptions in the archiving system. The need of a generalized I/O system is envisaged and a way to implement it is outlined

  4. Operation and maintenance manual for data acquisition system of MIDAS

    International Nuclear Information System (INIS)

    Lee, D. Y.; Park, W. M.; Kim, J. T.; Euh, D. J.

    2001-09-01

    This report describes an operation and maintenance manual of the data acquisition system and the data processing system for the DVI performance evaluation facility, MIDAS. The data acquisition system is implemented with VXI based system of Kinetic Systems TM , and the data processing PC. This report presents the configuration method and operation procedure for the operator. The modification procedure and method for functional extension and performance modification are also included for the future demand

  5. Select PC/windows flat to develop data acquisition system

    International Nuclear Information System (INIS)

    Zhang Jin

    1993-01-01

    Through needing analysis, and also, considering user's ability of payment, the characteristic of China computer market, the computer developing tending, and the system's compatibility and up grade capability, PC/Windows flat are selected to develop a data acquisition system

  6. UNIBUS processor interface for a FASTBUS data acquisition system

    International Nuclear Information System (INIS)

    Larwill, M.; Lagerlund, T.D.; Barsotti, E.; Taff, L.M.; Franzen, J.

    1981-01-01

    Current work on a FASTBUS data acquisition system at Fermilab is described. The system will consist of three pieces of FASTBUS hardware: a UNIBUS processor interface (UPI), a dual-ported bulk memory, and a FASTBUS ''event builder'' (i.e., data acquisition processor). Primary efforts have been on specifying and constructing a UPI. The present specification includes capability for all basic FASTBUS operations, including list processing of consecutive FASTBUS operations. Some possible FASTBUS data acquisition system architectures employing the UPI are discussed along with some detailed specifications of the UPI itself

  7. A nuclear data acquisition system flow control model

    International Nuclear Information System (INIS)

    Hack, S.N.

    1988-01-01

    A general Petri Net representation of a nuclear data acquisition system model is presented. This model provides for the unique requirements of a nuclear data acquisition system including the capabilities of concurrently acquiring asynchronous and synchronous data, of providing multiple priority levels of flow control arbitration, and of permitting multiple input sources to reside at the same priority without the problem of channel lockout caused by a high rate data source. Finally, a previously implemented gamma camera/physiological signal data acquisition system is described using the models presented

  8. Software aspects of designing an online data acquisition system

    International Nuclear Information System (INIS)

    Bandyopadhyay, A.

    1989-01-01

    The design aspect of a data acquisition system software for experimental nuclear physics applications is discussed. The features of a good data acquisition system and the techniques which are used to meet the requirements are also discussed. The suitability of different programming languages for different applications have been outlined. The operating system requirements and the difficulties encountered by the programmer for non-ideal operating system environment is also highlighted. (author)

  9. A higher level language data acquisition system (III) - the user data acquisition program

    International Nuclear Information System (INIS)

    Finn, J.M.; Gulbranson, R.L.; Huang, T.L.

    1983-01-01

    The nuclear physics group at the University of Illinois has implemented a data acquisition system using modified versions of the Concurrent Pascal and Sequential Pascal languages. The user, a physicist, develops a data acquisition ''operating system'', written in these higher level languages, which is tailored to the planned experiment. The user must include only those system functions which are essential to the task, thus improving efficiency. The user program is constructed from simple modules, mainly consisting of Concurrent Pascal PROCESSes, MONITORs, and CLASSes together with appropriate data type definitions. Entire programs can be put together using ''cut and paste'' techniques. Planned enhancements include the automating of this process. Systems written for the Perkin-Elmer 3220 using this approach can easily exceed 2 kHz data rates for event by event handling; 20 kHz data rates have been achieved by the addition of buffers in the interrupt handling software. These rates have been achieved without the use of special-purpose hardware such as micro-programmed branch drivers. With the addition of such devices even higher data rates should be possible

  10. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  11. Data acquisition system for fusion diagnostics on the ARGUS laser

    International Nuclear Information System (INIS)

    Greenwood, J.R.; Campbell, D.E.; Frerking, C.E.

    1976-09-01

    An extensive data acquisition and analysis system has been implemented for experiments on the ARGUS laser. The system is based upon a PDP-11/40 minicomputer and CAMAC interfaces. Highspeed transient digitizers, calorimeter digitizing modules and time integrated data are interfaced through CAMAC over a fiber optic serial highway. The system allows for dynamic definition of the experimental environment by an operator, automatic data acquisition during a shot. Two interactive graphics terminals allow experimenters real-time access to target shot data

  12. The data acquisition system for the JADE detector

    International Nuclear Information System (INIS)

    Cords, D.; Dittmann, P.; Eichler, R.; Mills, H.E.

    1985-07-01

    An outline of the data acquisition system for the JADE experiment at PETRA, DESY is presented. After describing the hardware configuration, we describe our guiding ideas for the design of the data acquisition system, which is followed by accounts of the implementation of real time software, the data flow, the monitoring and detector control as well as the online event analysis and filtering. Finally we summarise our experience with the system. (orig.)

  13. Aircraft Nodal Data Acquisition System (ANDAS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Development of an Aircraft Nodal Data Acquisition System (ANDAS) based upon the short haul Zigbee networking standard is proposed. It employs a very thin (135 um)...

  14. Online event filtering in the JADE data acquisition system

    International Nuclear Information System (INIS)

    Mills, H.E.

    1986-01-01

    The data acquisition system developed for the JADE experiment at PETRA, DESY includes the facility to use software to filter out background events. The design, implementation, testing and experience gained are discussed. (orig.)

  15. Extremelly High Bandwidth Rad Hard Data Acquisition System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Analog-to-digital converters (ADCs) are the key components for digitizing high-speed analog data in modern data acquisition systems, which is a critical part of...

  16. Recent developments of the RFX control and data acquisition system

    International Nuclear Information System (INIS)

    Barana, O.; Luchetta, A.; Manduchi, G.; Taliercio, C.

    2004-01-01

    Although the new RFX machine is still under modification, most power supply systems have been used since early 2003 for testing an ITER high-power by-pass switch. This has given us the opportunity to verify the effectiveness of several choices we made in the development of the new data acquisition and control system of RFX. The system has been renewed both in its control and data acquisition components. For control, the new system employs Simatic S7 PLCs and a commercial Supervisory Control and Data Acquisition (SCADA) tool. Many improvements have been made to the MDSplus-based data acquisition system. The whole system has been ported from OpenVMS to Linux, using a server for data storage and CAMAC data acquisition, and a set of CompactPCI crates, each hosting a Linux PC board. Device-specific code is now entirely implemented in TDI, the scripting language of MDSplus. Our experience in the new system has been positive, especially for the data acquisition system

  17. The data acquisition system for the ANTARES neutrino telescope

    International Nuclear Information System (INIS)

    Aguilar, J.A.; Albert, A.; Ameli, F.

    2007-01-01

    The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described

  18. The data acquisition system for the ANTARES neutrino telescope

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, J.A. [IFIC, Instituto de Fisica Corpuscular, Edificios Investigacion de Paterna, CSIC, Universitat de Valencia, Apdo. de Correos 22085, 46071 Valencia (Spain); Albert, A. [GRPHE - Groupe de Recherche en Physique des Hautes Energies, Universite de Haute Alsace, 61 Rue Albert Camus, 68093 Mulhouse Cedex (France); Ameli, F. [Dipartimento di Fisica dell' Universita ' La Sapienza' e Sezione INFN, P.le Aldo Moro 2, 00185 Rome (Italy)] (and others)

    2007-01-01

    The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described.

  19. Five channel data acquisition system for tracer studies

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhananjay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    Radioactive tracers are being used by many modern industries for trouble shooting, process control/quality control and optimization in the process plants. A five channel data acquisition system which has five independent scintillation detector based channels for data acquisition has been developed and made available. This system can be used for tracer studies involving Mean residence time, Resident time distribution and other similar parameters involving tracer movement. System developed can acquire data with dwell times ranging from 10 m sec to 100 sec into each channel and has a capacity to acquire data into 10K channels. Each channel electronics, has a 1x1 NaI Scintillation Detector probe, HV, AMP SCA, micro-controller based data acquisition card with independent dot matrix LCD display for visualization. Extensive use of serial bus (I 2 C, microwire) compatible devices has been incorporated in the design. Data acquisition is initiated simultaneously into all the channels. System design permits delayed/prompt data acquisition selectively. Dual counter switching technique has been employed to achieve faster dwell times for data acquisition. (author)

  20. Thermal Gradient Data Acquisition System Documentation

    National Research Council Canada - National Science Library

    Walker, Larry D; Robinson, Scott B; Leon, Lisa

    2004-01-01

    ... that can be recorded in mice. Since acceptable commercial systems are not available, this system was custom-built to acquire data using National Instruments' versatile hardware components and LabVIEW...

  1. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  2. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  3. Data acquisition system from uncorrelated experimental inputs

    International Nuclear Information System (INIS)

    Bals, I.; Caprini, M.; Goran, B.; Lutescu, S.; Niculescu, D.

    1974-01-01

    The system described in this work was performed as a small acquisition center for neutron physics experiment and was designed as a specialized device. The system was entirely MSI and SSI integrated circuits performed using 33 double sided printed circuit boards. The modular structure with information flow on buses led to wining simplification. The system can be further developed, using appropriate interfaces and programming modules to extend the range of possible experiments

  4. Data acquisition system in TPE-1RM15

    International Nuclear Information System (INIS)

    Yagi, Yasuyuki; Yahagi, Eiichi; Hirano, Yoichi; Shimada, Toshio; Hirota, Isao; Maejima, Yoshiki

    1991-01-01

    The data acquisition system for TPE-1RM15 reversed field pinch machine had been developed and has recently been completed. Thd data to be acquired consist of many channels of time series data which come from plasma diagnostics. The newly developed data acquisition system uses CAMAC (Computer Automated Measurement And Control) system as a front end data acquisition system and micro-VAX II for control, file management and analyses. Special computer programs, DAQR/D, have been developed for data acquisition routine. Experimental setting and process controlling items are managed by a parameter database in a shared common region and every task can easily refer to it. The acquired data are stored into a mass storage system (total of 1.3GBytes plus a magnetic tape system) including an optical disk system, which can save storage space and allow quick reference. At present, the CAMAC system has 88 (1MHz sampling) and 64(5kHz sampling) channels corresponding to 1.6 MBytes per shot. The data acquisition system can finish one routine within 5 minutes with 1.6MBytes data depending on the amount of graphic outputs. Hardwares and softwares of the system are specified so that the system can be easily expanded. The computer is connected to the AIST Ethernet and the system can be remotely accessed and the acquired data can be transferred to the mainframes on the network. Details about specifications and performance of the system are given in this report. (author)

  5. Multiparameter nuclear data acquisition and processing system

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, M; Turzo, I; Kristiak, J; Matousek, V [Inst. of Physics, Slovak Academy of Sciences, Bratislava (Slovakia)

    1996-12-31

    A modular system to determine correlations among many detection in radiation measurements is described. The capabilities of the system are illustrated of correlation between positron annihilation life-time and the momentum of electron-positron pairs using four detectors. 8 refs.

  6. STADUS - Ultrasonic data acquisition and processing system

    International Nuclear Information System (INIS)

    Saglio, Robert; Birac, A.M.; Frappier, J.C.

    1982-05-01

    The CEA (Commissariat a l'Energie Atomique) has developed a system for the acquisition and analysis of data recorded during ultrasonic testing. Initially this system was designed and built for the needs of in-service inspection of PWR type power reactors. It is in far wider use today for miscellaneous automatic ultrasonic inspection procedures. This system records, in digital form, the ultrasonic data supplied by the transducers (maximum 16 simultaneous channels), and the geometric coordinates defining the position of the inspection tool. Based on these data, which are recorded on floppy disk, this system helps to display data in the form of A SCAN, B SCAN and C SCAN images. In addition, processing programs of data transfer from the STADUS floppy disks have been developed and inserted on computers more powerful than the one used in the STADUS system. These programs serve to obtain different fault charts on an adjustable scale, as well as listings concerning the defect positions and dimensions [fr

  7. Data acquisition system for a deuteration chamber

    International Nuclear Information System (INIS)

    Monroy A, L.

    1994-01-01

    The work present is focusing auxiliary in the experiment the reaction of fusion in cold in the laboratory of Physical of Plasmas of Instituto Nacional de Investigaciones Nucleares. These systems of acquisition of data concrete to register in line surface of pressure and temperature in the gap of 5.6 x 10 -4 to 1 x 10 3 and -270 to 1300 Centigrade degrees with help of personal computer. The manner of purchase in chamber of Deuterium is per middle of thermocouple with the object of whereas any control of the temperature in different point in the some of manner the signal of in for the system is the thermocouple (milli volts), the conversion analogy a digital is mean of Cad of 12 bits rate double slope the out is mean the PPI to send the signal to P C of these manner the read of the thermocouples is translate graphic or digital in the screen of the P C. In the phase of pressure element sensor is measure type Pirani, the measure is of manner of temperature. (Author)

  8. ARM Processor Based Embedded System for Remote Data Acquisition

    OpenAIRE

    Raj Kumar Tiwari; Santosh Kumar Agrahari

    2014-01-01

    The embedded systems are widely used for the data acquisition. The data acquired may be used for monitoring various activity of the system or it can be used to control the parts of the system. Accessing various signals with remote location has greater advantage for multisite operation or unmanned systems. The remote data acquisition used in this paper is based on ARM processor. The Cortex M3 processor used in this system has in-built Ethernet controller which facilitate to acquire the remote ...

  9. An intelligent data acquisition system for fluid mechanics research

    Science.gov (United States)

    Cantwell, E. R.; Zilliac, G.; Fukunishi, Y.

    1989-01-01

    This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.

  10. Improvement of digital data acquisition system in reflood test rig

    International Nuclear Information System (INIS)

    Sudoh, Takashi; Murao, Yoshio; Niitsuma, Yasushi

    1979-03-01

    The original master digital data acquisition system was designed to collect 30 channels of analog data rapidly and convert them into digital form for recording on a magnetic tape. Due to the increases in the number of channels and the ranges of measurement, an additional acquisition device was needed for the original system. This report descrives the design of the additional data acquisition device and the results of performance tests. The operational manual is attached as an appendix. It was confirmed that the new system satisfied the requirements of system. (author)

  11. An introduction to LAMPF data acquisition system introduce

    International Nuclear Information System (INIS)

    Fu Saihong

    1993-01-01

    LAMPF Data Acquisition Systems are divided into general DAQ system and advanced MEGA DAQ system. The construct and future plan of general system are described. The second stage trigger has been implemented at LAMPF using a commercially available workstation and VME interface. The implementation is described and measurements of data transfer speeds are presented

  12. An improved data acquisition system for isotopic ratio mass spectrometers

    International Nuclear Information System (INIS)

    Saha, T.K.; Reddy, B.; Nazare, C.K.; Handu, V.K.

    1999-01-01

    Isotopic ratio mass spectrometers designed and fabricated to measure the isotopic ratios with a precision of better than 0.05%. In order to achieve this precision, the measurement system consisting of ion signal to voltage converters, analog to digital converters, and data acquisition electronics should be at least one order better than the overall precision of measurement. Using state of the art components and techniques, a data acquisition system, which is an improved version of the earlier system, has been designed and developed for use with multi-collector isotopic ratio mass spectrometers

  13. Parallel preprocessing in a nuclear data acquisition system

    International Nuclear Information System (INIS)

    Pichot, G.; Auriol, E.; Lemarchand, G.; Millaud, J.

    1977-01-01

    The appearance of microprocessors and large memory chips has somewhat modified the spectrum of tools usable by the data acquisition system designer. This is particular true in the nuclear research field where the data flow has been continuously growing as a consequence of the increasing capabilities of new detectors. This paper deals with the insertion, between a data acquisition system and a computer, of a preprocessing structure based on microprocessors and large capacity high speed memories. The results shows a significant improvement on several aspects in the operation of the system with returns paying back the investments in 18 months

  14. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  15. Data acquisition system for linear PSD based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, Anita; Ghodgaonkar, M.D.

    2001-01-01

    Single or multi-PSD configurations are used in different neutron diffractometer setups. A data acquisition system is developed to serve the gross requirements of all the diffractometer setups. It is also customized to specific requirements of different setups. The hardware is developed as a Transputer based add-on card. Most of the hardware functionality is handled in the Transputer program thus improving throughput of the system. The card can handle 16 RDCs, a few motor controls and on/off controls. The software comprises of a front-end Windows98 application, a Transputer program and a device driver. The data acquisition system performs data acquisition, analysis, display and storage. Analysis includes converting raw data of linear PSD to equiangular format, merging and clubbing the data to make a continuous equiangular spectrum. Calibration of individual PSD is a crucial activity in correctly merging the data coming from PSDs. (author)

  16. Review of Supervisory Control and Data Acquisition (SCADA) Systems

    Energy Technology Data Exchange (ETDEWEB)

    Reva Nickelson; Briam Johnson; Ken Barnes

    2004-01-01

    A review using open source information was performed to obtain data related to Supervisory Control and Data Acquisition (SCADA) systems used to supervise and control domestic electric power generation, transmission, and distribution. This report provides the technical details for the types of systems used, system disposal, cyber and physical security measures, network connections, and a gap analysis of SCADA security holes.

  17. An universal multi-parameter data acquisition system MOLDAS1

    International Nuclear Information System (INIS)

    Jiao Dunpang; Zhou Yanyen; Ge Wenxiu; Wang Yanyu; Yu Jusheng; Jing Lan

    1988-01-01

    MOLDAS1 is a data acquisition system to be used for data-taking from reactions induced by heavy-ion in IMP. Its configuration both on hardware and software, system control logic, data flow and functions are intraduced. System specification is discussed as well

  18. A data acquisition and analysis system for the RIBLL

    CERN Document Server

    Wenlong, Z; Zhong Yan, G; Guoqing, X; Jin Chuan W; Jia Xing, L; Xiang Wei, M; Shanhong, J; Lijun, Q; Quanjin, W

    2000-01-01

    The Radioactive Ion Beam Line in Lanzhou (RIBLL) is described. This system has been connected to a 100 M Ethernet and is run on the NT platform of MS windows. The system has adopted CAMAC specification and incorporates PAW and CERNLIB from CERN. It is a powerful and flexible data acquisition and analysis system with a rate of ~640 Kb /s. (4 refs).

  19. Operation of inspection data acquisition and evaluation system

    International Nuclear Information System (INIS)

    Takahashi, Yoichi; Harada, Hiroshi; Watanabe, Masayuki; Sakaguchi, Makoto; Ishikawa, Masayuki

    2016-01-01

    Rokkasho Reprocessing Plant (RRP) is a large scale plant to treat a huge amount of Plutonium significant for safeguards. The LArge SCAle Reprocessing plant safeguards (LASCAR) Forum recommended an effective utilization of unattended verification systems and automated data acquisition system etc. Based on LASCAR recommendation, Nuclear Material Control Center (NMCC) has developed the inspection data acquisition system as the automated data acquisition system from the unattended verification systems (including non-destructive assay equipment, solution monitoring system and surveillance camera). The data gathered from the unattended verification system are provided to the inspection data evaluation system for the State and the IAEA. In this development, redundancy concepts for data transfer line, in order to prevent inspection data missing, were introduced, and the timely confirmation of solution behaver such as material flows and inventories by the solution monitoring can be achieved. Furthermore, for purpose of efficiency of evaluation of inspection activity for the State, NMCC has developed the inspection data evaluation system which operates automated partition of inspection data coming from each verification equipment. Additionally, the inspection data system evaluation can manage the inspection activities and their efforts. These development and operation have been funded by JSGO (Japan Safeguards Office). This paper describes development history and operation of the inspection data acquisition and evaluation system. (author)

  20. A fast data acquisition system for PHA and MCS measurements

    International Nuclear Information System (INIS)

    Eijk, P.J.A. van; Keyser, C.J.; Rigterink, B.J.; Hasper, H.

    1985-01-01

    A microprocessor controlled data acquisition system for pulse height analysis and multichannel scaling is described. A 4K x 24 bit static memory is used to obtain a fast data acquisition rate. The system can store 12 bit ADC or TDC data within 150 ns. Operating commands can be entered via a small keyboard or by a RS-232-C interface. An oscilloscope is used to display a spectrum. The display of a spectrum or the transmission of spectrum data to an external computer causes only a short interruption of a measurement in progress and is accomplished by using a DMA circuit. The program is written in Modular Pascal and is divided into 15 modules. These implement 9 parallel processes which are synchronized by using semaphores. Hardware interrupts from the data acquisition, DMA, keyboard and RS-232-C circuits are used to signal these processes. (orig.)

  1. Data acquisition system for a proton imaging apparatus

    CERN Document Server

    Sipala, V; Bruzzi, M; Bucciolini, M; Candiano, G; Capineri, L; Cirrone, G A P; Civinini, C; Cuttone, G; Lo Presti, D; Marrazzo, L; Mazzaglia, E; Menichelli, D; Randazzo, N; Talamonti, C; Tesi, M; Valentini, S

    2009-01-01

    New developments in the proton-therapy field for cancer treatments, leaded Italian physics researchers to realize a proton imaging apparatus consisting of a silicon microstrip tracker to reconstruct the proton trajectories and a calorimeter to measure their residual energy. For clinical requirements, the detectors used and the data acquisition system should be able to sustain about 1 MHz proton rate. The tracker read-out, using an ASICs developed by the collaboration, acquires the signals detector and sends data in parallel to an FPGA. The YAG:Ce calorimeter generates also the global trigger. The data acquisition system and the results obtained in the calibration phase are presented and discussed.

  2. The ATLAS Data Acquisition and High Level Trigger system

    International Nuclear Information System (INIS)

    2016-01-01

    This paper describes the data acquisition and high level trigger system of the ATLAS experiment at the Large Hadron Collider at CERN, as deployed during Run 1. Data flow as well as control, configuration and monitoring aspects are addressed. An overview of the functionality of the system and of its performance is presented and design choices are discussed.

  3. A data-acquisition system for high speed linear CCD

    International Nuclear Information System (INIS)

    Liu Zhiyan; Chen Xiangcai; Jiang Xiaoshan; Zhang Hongyu; Liang Zhongwang; Xiang Haisheng; Hu Jun

    2010-01-01

    A data-acquisition system for high speed linear CCD (Charge Coupled device) is mainly introduced. The optical fiber transmission technology is used. The data is sent to PC through USB or PCI interface. The construction of the system, the design of the PCI interface hardware, software design and the design of the control program running on host computer are also introduced. (authors)

  4. Multiple-user data acquisition and analysis system

    International Nuclear Information System (INIS)

    Manzella, V.; Chrien, R.E.; Gill, R.L.; Liou, H.I.; Stelts, M.L.

    1981-01-01

    The nuclear physics program at the Brookhaven National Laboratory High Flux Beam Reactor (HFBR) employs a pair of PDP-11 computers for the dual functions of data acquisition and analysis. The data acquisition is accomplished through CAMAC and features a microprogrammed branch driver to accommodate various experimental inputs. The acquisition computer performs the functions of multi-channel analyzers, multiscaling and time-sequenced multichannel analyzers and gamma-ray coincidence analyzers. The data analysis computer is available for rapid processing of data tapes written by the acquisition computer. The ability to accommodate many users is facilitated by separating the data acquisition and analysis functions, and allowing each user to tailor the analysis to the specific requirements of his own experiment. The system is to be upgraded soon by the introduction of a dual port disk to allow a data base to be available to each computer

  5. Current position on software for the automatic data acquisition system

    International Nuclear Information System (INIS)

    1988-01-01

    This report describes the current concepts for software to control the operation of the Automatic Data Acquisition System (ADAS) proposed for the Deaf Smith County, Texas, Exploratory Shaft Facility (ESF). The purpose of this report is to provide conceptual details of how the ADAS software will execute the data acquisition function, and how the software will make collected information available to the test personnel, the Data Management Group (DMG), and other authorized users. It is not intended that this report describe all of the ADAS functions in exact detail, but the concepts included herein will form the basis for the formal ADAS functional requirements definition document. 5 refs., 14 figs

  6. Distributed data acquisition system for Pachmarhi array of Cverenkov telescopes

    Science.gov (United States)

    Upadhya, S. S.; Acharya, B. S.; Bhat, P. N.; Chitnis, V. R.; D'Souza, A. I.; Francis, P. J.; Gothe, K. S.; Joshi, S. R.; Majumdar, P.; Manogaran, M.; Nagesh, B. K.; Pose, M. S.; Purohit, P. N.; Rahman, M. A.; Rao, K. K.; Rao, S. K.; Sharma, S. K.; Singh, B. B.; Stanislaus, A. J.; Sudersanan, P. V.; Venkatesh Murthy, B. L.; Vishwanath, P. R.

    2002-03-01

    Pachmarhi Array of Cverenkov Telescopes consists of 25 Telescopes distributed within an area of 8000m2. The array was designed to detect and process faint Cverenkov light flashes that lasts for a few nanoseconds, produced in the atmosphere by celestial VHE ?-rays or cosmic rays. In this experiment, the arrival time and amplitude of fast tiny pulses have to be measured and recorded from each of 175 photo-tubes in a shortest possible time. In view of the complexity of the system, the entire array is divided into 4 sectors. A Distributed Data Acquisition System developed for the purpose consists of independent Sector Data Acquisition Systems and a Master Data Acquisition System. The distributed data acquisition and monitoring system are built using PC's which are networked through LAN. The entire software for DDAS was developed in-house in C language under LINUX environment. Also, most of the hardware barring a few fast digitization modules were designed and fabricated in-house. The design features, implementation strategy as well as the performance of the whole system are discussed.

  7. Design of gamma camera data acquisition system based on PCI9810

    International Nuclear Information System (INIS)

    Zhao Yuanyuan; Zhao Shujun; Liu Yang

    2004-01-01

    This paper describe the design of gamma camera's data acquisition system, which is based on PCI9810 data acquisition card of ADLink Technology Inc. The main function of PCI9810 and the program of data acquisition system are described. (authors)

  8. Data acquisition systems for high energy physics experiments

    International Nuclear Information System (INIS)

    Duran, I.; Olmos, P.

    1986-01-01

    The Data Acquisition Systems most frequently used in High Energy Physics experiments is described. This report begins with a brief description of the main elements of a typical signal processing chain, following with a detailed exposition of the four most popular instrumentation standards used in this kind of experiments: NIM, CAMAC, and VMI. (author). 20 figs., 9 ref

  9. A status report on the SLD data acquisition system

    International Nuclear Information System (INIS)

    1988-11-01

    The basic design of the SLD data acquisition system and its present status are reviewed. Aspects of the design that take particular advantage of the relatively low e + e/sup /minus// cross section and the low beam crossing rate of a linear collider are explained. 14 refs., 8 figs

  10. ACP/R3000 processors in data acquisition systems

    International Nuclear Information System (INIS)

    Deppe, J.; Areti, H.; Atac, R.

    1989-02-01

    We describe ACP/R3000 processor based data acquisition systems for high energy physics. This VME bus compatible processor board, with a computational power equivalent to 15 VAX 11/780s or better, contains 8 Mb of memory for event buffering and has a high speed secondary bus that allows data gathering from front end electronics. 2 refs., 3 figs

  11. The implement of java based GUI for data acquisition system

    International Nuclear Information System (INIS)

    Yang Xiaoqing

    2003-01-01

    Web based technique have been used to produce a Graphic User Interface framework for small Data Acquisition System. A CORBA library used for the communication with the JRCS servers. The GUI was implemented by Java Swing. the integration between Java and CORBA provide a powerful independent distributed environment. (authors)

  12. Minicomputer data acquisition system for nuclear physics applications

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, R [Princeton Univ., NJ (USA). Joseph Henry Labs.

    1978-09-15

    The data acquisition system for the Princeton Cyclotron facility based on a Data General Eclipse computer is described. The program ACQUIRE is a highly flexible acquisition code able to support diverse experimental requirements and yet capable of sorting a repetitious pulser in a single ADC at up to 40 kHz without loss.

  13. Data acquisition systems for high energy Physics experiments

    International Nuclear Information System (INIS)

    Duran, I.; Olmos, P.

    1986-01-01

    We describe here the Data Acquisition Systems most frequently used in High Energy Physics experiments. This report begins with a brief description of the main elements of a typical signal processing chain, following with a detailed exposition of the four most popular instrumentation standards used in this kind of experimental: NIM, CAMAC, FASTBUS and VME. (Author) 9 refs

  14. 40 CFR 205.54-2 - Sound data acquisition system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Sound data acquisition system. 205.54-2 Section 205.54-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound...

  15. A microprocessor based multiscaling data acquisition system for moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Bohm, C.; Ekdahl, T.

    1985-01-01

    A microprocessor based data acquisition system is described, which was developed for use in Moessbauer spectroscopy. It is designed to record two spectra simultaneously, one of which could be a calibration spectrum. It is autonomous, but uses a host computer for initialization and permanent storage of data. The host communication software is also described. (Author)

  16. Engineered barrier experiment. Power control and data acquisition systems

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J.M.; Gamero, E.; Martin, P.L.; Molinero, A.; Navarrete, J.J.; Yuste, C.

    1997-01-01

    The engineered barrier concept for the storage of radioactive wastes is being tested at almost full scale at CIEMAT facilities. A data acquisition and control is an element of this experiment. This system would be operating for next three years. (Author)

  17. The data acquisition system for the TASSO experiment

    International Nuclear Information System (INIS)

    Quarrie, D.R.

    1981-06-01

    The TASSO experiment at PETRA uses a Norsk Data NORD-10S for monitoring and control of the experiment. Trigger rates of typically 1 to 10 Hz are accepted and data are sent via a high speed link to the Central DESY IBM Triplex for later off-line analysis. This data acquisition system is described. (author)

  18. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  19. An updated data acquisition and analysis system at RIBLL

    International Nuclear Information System (INIS)

    Chen, Z.Q.; Ye, Y.L.; Zhan, W.L.; Xiao, G.Q.; Guo, Z.Y.; Xu, H.S.; Wang, J.C.; Jiang, D.X.; Wang, Q.J.; Zheng, T.; Zhang, G.L.; Wu, C.E.; Li, Z.H.; Li, X.Q.; Hu, Q.Y.; Pang, D.Y.; Wang, J.

    2005-01-01

    An updated data acquisition and analysis system for beam tuning and nuclear physics experiments at RIBLL is presented. The system hardware is based on standard CAMAC bus with SCSI KSC3929-Z1B crate controller. The system software has a user-friendly GUI which is written in C/C++ language using Microsoft Visual C++ .Net 2003 with ROOT class library and runs under PC-based Windows 2000 operating system. The performance of the DAQ system is reliable and safe

  20. Design considerations for a multiprocessor based data acquisition system

    International Nuclear Information System (INIS)

    Tippie, J.W.; Kulaga, J.E.

    1979-01-01

    The rapid advance of digital technology has provided the systems designer with many new design options. Hardware is no longer the controlling expense. Complex operating systems provide the flexibility and development tools needed by software designers, but restrict throughput. Multiprocessor-based systems can be used to ''front-end'' high-throughput applications while maintaining the many advantages offered by multitasking operating systems. The design of a high-throughput data acquisition system for application in low energy nuclear physics is considered

  1. Progress on the data acquisition system at NSCL

    International Nuclear Information System (INIS)

    Fox, R.; Au, R.; Glynn, T.; Pollack, B.; Vander Mulen, A.

    1985-01-01

    We report on the progress made in data acquisition software development. Specifically, a unique generalized data routing scheme has been developed which allows user online analysis programs to be safely integrated into the acquisition system without endangering data sent to event recording devices. We describe the structure of the system. Performance is discussed and throughput calculated from it. User experience with the system is also discussed. We show how this routing system may easily be adapted to loosely coupled multiprocessor systems

  2. Development of data acquisition software for VME based system

    International Nuclear Information System (INIS)

    Kumar, A.; Chatterjee, A.; Mahata, K.; Ramachandran, K.

    2012-01-01

    A data acquisition system for VME has been developed for use in accelerator based experiments. The development was motivated by the growing demand for higher throughput in view of the increasing size of experiments. VME based data acquisition system provides a powerful alternative to CAMAC standards on account of higher readout speeds (100 ns/word) resulting in reduced dead time. Further, high density VME modules are capable of providing up to 640 channels in a single VME crate with 21 slots. The software system LAMPS, earlier developed for CAMAC based system and used extensively in our laboratory and elsewhere has been modified for the present VME based system. The system makes use of the VME library to implement Chain Block Transfer Readout (CBLT) and gives the option of both Polling and Interrupt mode to acquire data. Practical throughput of ∼ 250 ns/word in zero suppressed mode has been achieved. (author)

  3. Front-end data processing the SLD data acquisition system

    International Nuclear Information System (INIS)

    Nielsen, B.S.

    1986-07-01

    The data acquisition system for the SLD detector will make extensive use of parallel at the front-end level. Fastbus acquisition modules are being built with powerful processing capabilities for calibration, data reduction and further pre-processing of the large amount of analog data handled by each module. This paper describes the read-out electronics chain and data pre-processing system adapted for most of the detector channels, exemplified by the central drift chamber waveform digitization and processing system

  4. Mark-II Data Acquisition and Trigger system

    International Nuclear Information System (INIS)

    Breidenbach, M.

    1984-06-01

    The Mark-II Data Acquisition and Trigger system requirements and general solution are described. The solution takes advantage of the synchronous crossing times and low event rates of an electron positron collider to permit a very highly multiplexed analog scheme to be effective. The system depends on a two level trigger to operate with acceptable dead time. The trigger, multiplexing, data reduction, calibration, and CAMAC systems are described

  5. A camac data acquisition system based on PC-Linux

    International Nuclear Information System (INIS)

    Ribas, R.V.

    2002-01-01

    A multi-parametric data acquisition system for Nuclear Physics experiments using camac instrumentation on a personal computer with the Linux operating system in described. The system is very reliable, inexpensive and is capable of handling event rates up to 4-6 k events/s. In the present version, the maximum number of parameters to be acquired is limited only by the number of camac modules that can be fitted in one camac crate

  6. Data acquisition system and analysis programme for environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    Rajaram, S.; Kannan, V.; Hegde, A.G.

    2003-01-01

    Full text: In every Environmental Survey Laboratory (ESL) many nuclear radiation detecting instruments such as low level Gas Flow Beta Counting Systems, Gross Alpha Counting Systems, Gamma Counting Systems (Single Channel Analyser) are in use to detect the environmental radiation level. These instruments give output in terms of number (total pulse event counts), which is further manually converted into activity concentration per unit weight of the environmental samples. There is considerable difficulty and delay in obtaining the data, since calculations are done manually and also it is very difficult to maintain database of these results for future reference. In order to overcome all this difficulties a Data Acquisition System and Analysing Software Programme has been designed and developed. This paper describes the design and development of the Data Acquisition System using PCL-830 Counter Timer add on card, for networking the environmental radioactivity monitoring equipment's, which is under routine operation at ESL Kalpakkam

  7. A data acquisition system for elementary particle physics

    International Nuclear Information System (INIS)

    Grittenden, J.A.; Benenson, G.; Cunitz, H.; Hsuing, Y.B.; Kaplan, D.M.; Sippach, W.; Stern, B.

    1984-01-01

    The data acquisition system experiment 605 at the Fermi National Accelerator Laboratory employs a set of data transfer protocols developed at Columbia University and implemented in the Nevis Laboratories Data Transport System. The authors describe the logical design of the Transport System, its physical realization, and its particular application during the Spring, 1982 data run of experiment 605. During that run it served as the interface between the data latches and a megabyte of fast memory, operating at a data transfer rate of 200 nsec/16-bit word. Up to two thousand events were read out during the one second beam spill, each event consisting of about 250 words. Included are details of proposed improvements to the data acquisition system and append a brief comment of the need for inexpensive, versatile readout systems in experimental elementary particle physics

  8. Autonomous data acquisition system for Paks NPP process noise signals

    International Nuclear Information System (INIS)

    Lipcsei, S.; Kiss, S.; Czibok, T.; Dezso, Z.; Horvath, Cs.

    2005-01-01

    A prototype of a new concept noise diagnostics data acquisition system has been developed recently to renew the aged present system. This new system is capable of collecting the whole available noise signal set simultaneously. Signal plugging and data acquisition are performed by autonomous systems (installed at each reactor unit) that are controlled through the standard plant network from a central computer installed at a suitable location. Experts can use this central unit to process and archive data series downloaded from the reactor units. This central unit also provides selected noise diagnostics information for other departments. The paper describes the hardware and software architecture of the new system in detail, emphasising the potential benefits of the new approach. (author)

  9. An integrated, multi-vendor distributed data acquisition system

    International Nuclear Information System (INIS)

    Butner, D.N.; Drlik, M.; Meyer, W.H.; Moller, J.M.; Preckshot, G.G.

    1988-01-01

    A distributed data acquisition system that uses various computer hardware and software is being developed to support magnetic fusion experiments at Lawrence Livermore National Laboratory (LLNL). The experimental sequence of operations is controlled by a supervisory program, which coordinates software running on Digital Equipment Corporation (DEC) VAX computers, Hewlett-Packard (HP) UNIX-based workstations, and HP BASIC desktop computers. An interprocess communication system (IPCS) allows programs to communicate with one another in a standard manner regardless of program location in the network or of operating system and hardware differences. We discuss the design and implementation of this data acquisition system with particular emphasis on the coordination model and the IPCS. 5 refs., 3 figs

  10. Software development for a switch-based data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Booth, A. (Superconducting Super Collider Lab., Dallas, TX (United States)); Black, D.; Walsh, D. (Fermi National Accelerator Lab., Batavia, IL (United States))

    1991-12-01

    We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an integrated systems engineering'' environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

  11. Data acquisition and processing system for reactor noise analysis

    International Nuclear Information System (INIS)

    Costa Oliveira, J.; Morais Da Veiga, C.; Forjaz Trigueiros, D.; Pombo Duarte, J.

    1975-01-01

    A data acquisition and processing system for reactor noise analysis by time correlation methods is described, consisting in one to four data feeding channels (transducer, associated electronics and V/f converter), a sampling unit, a landline transmission system and a PDP 15 computer. This system is being applied to study the kinetic parameters of the 'Reactor Portugues de Investigacao', a swimming-pool 1MW reactor. The main features that make such a data acquisition and processing system a useful tool to perform noise analysis are: the improved characteristics of analog-to-digital converters employed to quantize the signals; the use of an on-line computer which allows a great accumulation and a rapid treatment of data together with an easy check of the correctness of the experiments; and the adoption of the time cross-correlation technique using two-detectors which by-pass the limitation of low efficiency detectors. (author)

  12. A new data acquisition system for pelletron-LINAC experiments

    International Nuclear Information System (INIS)

    Ramachandran, K.; Chatterjee, A.; Singh, Sudheer; Jha, K.; Joy, Saju; Behere, A.; Goadgoankar, M.D.

    2007-01-01

    The LINAC booster facility coupled with Pelletron accelerator at Mumbai and the plans to have large detector arrays such as Indian National Gamma Array, Charged Particle Array, Neutron Array, BaF 2 etc. pose new challenges to have a Data Acquisition system (DAQ) with a throughput an order of magnitude higher than the present CAMAC system. The major limitation of CAMAC readout is the 1μs/word readout time. A new FERA (Fast Encoding and Readout) data acquisition system developed at BARC for the augmentation of the throughput of CAMAC is a readout bus for the CAMAC ADCs. With this FERA DAQ, it is possible to readout CAMAC ADC's at 150 ns/word. This talk will present the new DAQ system used at BARC-TIFR Pelletron Accelerator facility. (author)

  13. Experiment data acquisition and analysis system. Vol. 1

    International Nuclear Information System (INIS)

    Busch, F.; Croome, D.; Goeringer, H.; Hartmann, V.; Lowsky, J.; Marinescu, D.; Richter, M.; Winkelmann, K.

    1983-08-01

    The Experiment Data Acquisition and Analysis System EDAS was created to acquire and analyze data collected in experiments carried out at the heavy ion accelerator UNILAC. It has been available since 1975 and has become the most frequently used system for evaluating experiments at GSI. EDAS has undergone constant development, and the many enhancements make this completely revised third edition of the EDAS manual necessary. EDAS consists of two sub-systems: GOLDA for experimental data acquisition on PDP-11's and SATAN mainly for off-line analysis in replay mode on large IBM mainframes. The capacity of one IBM 3081 CPU is mainly dedicated to EDAS processing and is almost fully utilized by this application. More than 200 users from GSI as well as from collaborating laboratories and universities use SATAN in more than 100 sessions daily needing 10 to 20 hours of user CPU time. EDAS is designed as an open system. (orig./HSI)

  14. A data acquisition system for silicon microstrip detectors

    International Nuclear Information System (INIS)

    Adriani, O.; Civinini, C.; D'Alessandro, R.; Meschini, M.; Pieri, M.; Castellini, G.

    1998-01-01

    Following initial work on the readout of the L3 silicon microvertex detector, the authors have developed a complete data acquisition system for silicon microstrip detectors for use both in their home institute and at the various test beam facilities at the CERN laboratory. The system uses extensive decoupling schemes allowing a fully floating connection to the detector. This feature has many advantages especially in the readout of the latest double-sided silicon microstrip detectors

  15. The data acquisition system for a SPECT with cylindrical detector

    International Nuclear Information System (INIS)

    Jin Yongjie; Liu Yinong; Li Yuanjing

    1995-01-01

    The data acquisition and position estimation system has been developed for a multi-crystal SPECT with modular cylindrical detector. The electronics screen photon energy determines the detector module stricken by incident photon. The relevant PMT outputs are digitized and passed onto a Pentium PC. Then PMT gain normalization, detector bar identification, energy correction, event coordinates calculation and linearity correction are real-time performed by the PC. The system has been employed in clinical brain imaging

  16. Data acquisition system for segmented reactor antineutrino detector

    Czech Academy of Sciences Publication Activity Database

    Hons, Zdeněk; Vlášek, J.

    2017-01-01

    Roč. 12, č. 1 (2017), č. článku P01022. ISSN 1748-0221 R&D Projects: GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : Data acquisition concepts * Detector control systems (detector and experiment monitoring and slow-control system, architecture , hardware, algorithms, databases) * Neutrino detectors Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Nuclear physics Impact factor: 1.220, year: 2016

  17. Object oriented run control for the CEBAF data acquisition system

    International Nuclear Information System (INIS)

    Quarrie, D.R.; Heyes, G.; Jastrzembski, E.; Watson, W.A. III

    1992-01-01

    After an extensive evaluation, the Eiffel object oriented language has been selected for the design and implementation of the run control portion of the CEBAF Data Acquisition System. The OSF/Motif graphical user interface toolkit and Data Views process control system have been incorporated into this framework. in this paper, the authors discuss the evaluation process, the status of the implementation and the lessons learned, particularly in the use of object oriented techniques

  18. New data acquisition system for the lujan center

    International Nuclear Information System (INIS)

    Nelson, R.; Bowling, P.S.; Cooper, G.M.; Kozlowski, T.

    2001-01-01

    To meet the data acquisition requirements for six new neutron scattering instruments at the Los Alamos Science Center (LANSCE), we are building systems using Web tools, commercial hardware and software, software developed by the controls community, and custom hardware developed by the neutron scattering community. To service these new instruments as well as seven existing instruments, our data acquisition system needs common software and hardware core capabilities and the means to flexibly integrate them while differentiating the needs of the diverse instrument suite. Neutron events are captured and processed in VXI modules while controls for sample environment and beam line setup are processed with PCs. Typically users access the system through web browsers. (author)

  19. Run control techniques for the Fermilab DART data acquisition system

    International Nuclear Information System (INIS)

    Oleynik, G.; Engelfried, J.; Mengel, L.; Moore, C.; Pordes, R.; Udumula, L.; Votava, M.; Drunen, E. van; Zioulas, G.

    1996-01-01

    DART is the high speed, Unix based data acquisition system being developed by the Fermilab Computing Division in collaboration with eight High Energy Physics Experiments. This paper describes DART run-control which implements flexible, distributed, extensible and portable paradigms for the control monitoring of a data acquisition systems. We discuss the unique and interesting aspects of the run-control - why we chose the concepts we did, the benefits we have seen from the choices we made, as well as our experiences in deploying and supporting it for experiments during their commissioning and sub-system testing phases. We emphasize the software and techniques we believe are extensible to future use, and potential future modifications and extensions for those we feel are not. (author)

  20. New data acquisition system for the lujan center

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, R.; Bowling, P.S.; Cooper, G.M.; Kozlowski, T. [Los Alamos National Loboratory, Los Alamos, NM (United States)

    2001-03-01

    To meet the data acquisition requirements for six new neutron scattering instruments at the Los Alamos Science Center (LANSCE), we are building systems using Web tools, commercial hardware and software, software developed by the controls community, and custom hardware developed by the neutron scattering community. To service these new instruments as well as seven existing instruments, our data acquisition system needs common software and hardware core capabilities and the means to flexibly integrate them while differentiating the needs of the diverse instrument suite. Neutron events are captured and processed in VXI modules while controls for sample environment and beam line setup are processed with PCs. Typically users access the system through web browsers. (author)

  1. Proposed data acquisition system for the Fermilab Booster

    International Nuclear Information System (INIS)

    Bharadwaj, V.; Peggs, S.; Wu, G.; Saltmarsh, C.

    1991-01-01

    At present, studies involving the FNAL Booster (or in fact most accelerators) depend on knowing exactly what detector one has to look at and at what time. Because of this, most studies are done 'on-line' and involve looking for repetitive effects using a limited number of detectors. In this paper the authors propose to design a Booster Data Acquisition System (BDAQ) for the FNAL Booster. In essence this system consists of a large number of digitizers with circular memory buffers. After a machine cycle of interest, these buffers are frozen and then read out into a mass storage device. This paper discusses the hardware and software capabilities needed to make such a data acquisition system a powerful tool for doing accelerator physics studies and improving machine performance

  2. Run control techniques for the Fermilab DART data acquisition system

    International Nuclear Information System (INIS)

    Oleynik, G.; Engelfried, J.; Mengel, L.

    1995-10-01

    DART is the high speed, Unix based data acquisition system being developed by the Fermilab Computing Division in collaboration with eight High Energy Physics Experiments. This paper describes DART run-control which implements flexible, distributed, extensible and portable paradigms for the control and monitoring of data acquisition systems. We discuss the unique and interesting aspects of the run-control - why we chose the concepts we did, the benefits we have seen from the choices we made, as well as our experiences in deploying and supporting it for experiments during their commissioning and sub-system testing phases. We emphasize the software and techniques we believe are extensible to future use, and potential future modifications and extensions for those we feel are not

  3. Data acquisition and control system for SMARTEX – C

    Energy Technology Data Exchange (ETDEWEB)

    Yeole, Yogesh Govind, E-mail: yogesh@ipr.res.in [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India); Lachhvani, Lavkesh; Bajpai, Manu; Rathod, Surendrasingh; Kumar, Abhijeet; Sathyanarayana, K.; Pujara, H.D. [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India); Pahari, Sambaran [BARC, Vishakhapatanam, 530 012 Andhra Pradesh (India); Chattopadhyay, Prabal K. [Institute for Plasma Research, Gandhinagar, 382 428 Gujarat (India)

    2016-11-15

    Highlights: • We have developed control and data acquisition system for Nonneutral Plasma experiment named as SMARTEX – C. • The hardware of the system includes a high current power supply, a trigger circuit, a comparator circuit, a PXI system and a computer. • The software has been developed in LabVIEW{sup ®}. • We have presented the complete time synchronization of the operation of the system. • Results obtained from the equipment has been shown. - Abstract: A PXI based data acquisition system has been developed for Small Aspect Ratio Toroidal Experiment in C – shaped geometry (SMARTEX – C), a device to create and confine non-neutral plasma. The data acquisition system (DAQ) includes PXI based data acquisition cards, communication card, chassis, Optical fiber link, a dedicated computer, a trigger circuit (TC) and a voltage comparator. In this paper, we report the development of a comprehensive code in LabVIEW{sup ®} – 2012 software in order to control the operation of SMARTEX – C as well as to acquire the experimental data from it. The code has been incorporated with features like configuration of card parameters. A hardware based control sequence involving TC has also been developed and integrated with the DAQ. In the acquisition part, the data from an experimental shot is acquired when a digital pulse from one of the PXI cards triggers TC, which further triggers the TF – power supply and rest of the DAQ. The data hence acquired, is stored in the hard disc in binary format for further analysis.

  4. Multi-channel data acquisition system with absolute time synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Włodarczyk, Przemysław, E-mail: pan.wlodarczyk@uj.edu.pl [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland); Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Pustelny, Szymon, E-mail: pustelny@uj.edu.pl [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków (Poland); Budker, Dmitry [Department of Physics, University of California at Berkeley, Berkeley, California 94720-7300 (United States); Lipiński, Marcin [Department of Electronics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Kraków (Poland)

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics – GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  5. Multi-channel data acquisition system with absolute time synchronization

    Science.gov (United States)

    Włodarczyk, Przemysław; Pustelny, Szymon; Budker, Dmitry; Lipiński, Marcin

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics - GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  6. A small Unix-based data acquisition system

    International Nuclear Information System (INIS)

    Engberg, D.; Glanzman, T.

    1993-06-01

    The proposed SLAC B Factory detector plans to use Unix-based machines for all aspects of computing, including real-time data acquisition and experimental control. An R ampersand D program has been established to investigate the use of Unix in the various aspects of experimental computation. Earlier R ampersand D work investigated the basic real-time aspects of the IBM RS/6000 workstation running AIX. The next step in this R ampersand D is the construction of prototype data acquisition system which attempts to exercise many of the features needed in the final on-line system in a realistic situation. For this project, we have combined efforts with a team studying the use of novel cell designs and gas mixtures in a new prototype drift chamber

  7. ORELA data acquisition system hardware. Volume 1: introduction

    International Nuclear Information System (INIS)

    Reynolds, J.W.

    1977-01-01

    The Oak Ridge Electron Linear Accelerator Facility (ORELA) has been specifically designed as a facility for neutron cross-section measurements by the time-of-flight technique. ORELA was designed so that a number of cross-section experiments can be performed simultaneously. This goal of simultaneous operation of several experiments, a maximum of six to date, has been achieved by using the multiple flight paths radiating from the target room, the multiple flight stations on each flight path, the laboratory facilities surrounding the central data area, and a shared data acquisition computer system. The flight stations contain the fast electronics for initial processing of the nuclear detector signals on a time scale of nanoseconds. The laboratories, and in some cases the flight stations, contain the equipment to digitize the nanosecond detector signals on a time scale of a few microseconds. At this point, the data passes into the ORELA Data Acquisition portion of the ORELA Data Handling System. An introduction to the ORELA Data Acquisition System is given, and the component parts of the system are briefly reviewed. Each specifically designed piece of hardware is briefly described with a simplified block diagram. Modifications to standard peripheral devices are reviewed. A list of drawings and programming notes are also included

  8. A research of a high precision multichannel data acquisition system

    Science.gov (United States)

    Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei

    2013-08-01

    The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.

  9. DATA ACQUISITION FOR SNS BEAM LOSS MONITOR SYSTEM

    International Nuclear Information System (INIS)

    YENG, Y.; GASSNER, D.; HOFF, L.; WITKOVER, R.

    2003-01-01

    The Spallation Neutron Source (SNS) beam loss monitor system uses VME based electronics to measure the radiation produced by lost beam. Beam loss signals from cylindrical argon-filled ion chambers and neutron detectors will be conditioned in analog front-end (AFE) circuitry. These signals will be digitized and further processed in a dedicated VME crate. Fast beam inhibit and low-level, long-term loss warnings will be generated to provide machine protection. The fast loss data will have a bandwidth of 35kHz. While the low level, long-term loss data will have much higher sensitivity. This is further complicated by the 3 decade range of intensity as the Ring accumulates beam. Therefore a bandwidth of 100kHz and dynamic range larger than 21 bits data acquisition system will be required for this purpose. Based on the evaluation of several commercial ADC modules in preliminary design phase, a 24 bits Sigma-Delta data acquisition VME bus card was chosen as the SNS BLM digitizer. An associated vxworks driver and EPICS device support module also have been developed at BNL. Simulating test results showed this system is fully qualified for both fast loss and low-level, long-term loss application. The first prototype including data acquisition hardware setup and EPICS software (running database and OPI clients) will be used in SNS Drift Tube Linac (DTL) system commissioning

  10. A remote data acquisition and control system for Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Zhou Qingguo; Wang Li; Wang Yanlong; Zhao Hong; Zhou Rongjie

    2004-01-01

    A remote data acquisition and control system for Moessbauer spectroscopy based on an embedded computer with the Mini Real-Time Linux operating system is presented. This system can be accessed by an Internet browser or a Java application program, which is designed especially for this purpose. So controlling this system is simple and the interface is user friendly. The components of this system can easily be obtained. So it could be built in most laboratories. We have succeeded in designing and developing this system, as well as using the system at the Key Laboratory for Magnetism and Magnetic Material of Ministry of Education, Lanzhou University, PR China

  11. Automatic Control and Data Acquisition System for Combustion Laboratory Applications.

    Science.gov (United States)

    1982-10-01

    O VPI Access~.ion FCr- 1473 2 UNCLASSIFIED Approved for public release; distribution unlimited JAutomatic Control and Data Acquisition System for...unit. The CPU/ROK board includes a 16 bit microprocessor chip which decodes and executes all in- structions, and controls all data transfers. The 12K...in the limited memory space of 32K of the HP-85 33 ACQDTA’ 1) Controls DevicesCRAIN ,2) Acquires Photodiods Output$ 3) Stores Data o Disc 1

  12. A VMEbus general-purpose data acquisition system

    International Nuclear Information System (INIS)

    Ninane, A.; Nemry, M.; Martou, J.L.; Somers, F.

    1992-01-01

    We present a general-purpose, VMEbus based, multiprocessor data acquisition and monitoring system. Events, handled by a master CPU, are kept at the disposal of data storage and monitoring processes which can run on distinct processors. They access either the complete set of data or a fraction of them, minimizing the acquisition dead-time. The system is built with the VxWorks 5.0 real time kernel to which we have added device drivers for data acquisition and monitoring. The acquisition is controlled and the data are displayed on a workstation. The user interface is written in C ++ and re-uses the classes of the Interviews and the NIH libraries. The communication between the control workstation and the VMEbus processors is made through SUN RPCs on an Ethernet link. The system will be used for, CAMAC based, data acquisition for nuclear physics experiments as well as for the VXI data taking with the 4π configuration (100 neutron detectors) of the Brussels-Caen-Louvian-Strasbourg DEMON collaboration. (author)

  13. The Resource Manager the ATLAS Trigger and Data Acquisition System

    CERN Document Server

    Aleksandrov, Igor; The ATLAS collaboration; Lehmann Miotto, Giovanna; Soloviev, Igor

    2016-01-01

    The Resource Manager of the ATLAS Trigger and Data Acquisition system The Resource Manager is one of the core components of the Data Acquisition system of the ATLAS experiment at the LHC. The Resource Manager marshals the right for applications to access resources which may exist in multiple but limited copies, in order to avoid conflicts due to program faults or operator errors. The access to resources is managed in a manner similar to what a lock manager would do in other software systems. All the available resources and their association to software processes are described in the Data Acquisition configuration database. The Resource Manager is queried about the availability of resources every time an application needs to be started. The Resource Manager’s design is based on a client-server model, hence it consists of two components: the Resource Manager "server" application and the "client" shared library. The Resource Manager server implements all the needed functionalities, while the Resource Manager c...

  14. The data acquisition system of the RFX experiment

    International Nuclear Information System (INIS)

    Manduchi, G.; Luchetta, A.; Taliercio, C.; Vitturi, S.

    1999-01-01

    The paper describes the experience gained in the development and maintenance of the data acquisition system for the RFX nuclear fusion experiment. The design of the system core started in 1987 and the system was ready at the beginning of the machine operation in late 1991. Since the early design stage it was clear that a careful definition of the system architecture was crucial for allowing the system to cope with the expected improvement in the hardware performance. Not all the initial design choices proved successful for this purpose. In the paper the (positive or negative) consequences of the main design choices of the system are reported. (orig.)

  15. A microcomputer-based data acquisition system for ECG, body and ambient temperatures measurement during bathing.

    Science.gov (United States)

    Uokawa, Y; Yonezawa, Y; Caldwell, W M; Hahn, A W

    2000-01-01

    A data acquisition system employing a low power 8 bit microcomputer has been developed for heart rate variability monitoring before, during and after bathing. The system consists of three integral chest electrodes, two temperature sensors, an instrumentation amplifier, a low power 8-bit single chip microcomputer (SMC) and a 4 MB compact flash memory (CFM). The ECG from the electrodes is converted to an 8-bit digital format at a 1 ms rate by an A/D converter in the SMC. Both signals from the body and ambient temperature sensors are converted to an 8-bit digital format every 1 second. These data are stored by the CFM. The system is powered by a rechargeable 3.6 V lithium battery. The 4 x 11 x 1 cm system is encapsulated in epoxy and silicone, yielding a total volume of 44 cc. The weight is 100 g.

  16. The MDSplus data acquisition system, current status and future directions

    International Nuclear Information System (INIS)

    Stillerman, J.; Fredian, T.W.

    1999-01-01

    The MDSplus data acquisition system was developed in collaboration with the ZTH group at Los Alamos National Laboratory and the RFX group at CNR in Padua, Italy and is currently in use at MIT, RFX in Padua, and TCV at EPFL in Lausanne. MDSplus is based on a hierarchical experiment description which completely describes the data acquisition and analysis tasks and contains the results from these operations. It also includes a set of X/motif based tools for data acquisition and display, as well as diagnostic configuration and management. These tools were designed to operate in a distributed, client/server environment with multiple concurrent readers and writers to the data store. An interface to a relational database is provided for storage and management of processed data. A commercially available package called IDL is used as the primary data analysis and visualization tool. The current projects include a new interface to the electronic logbook, tools for remote collaborators and WWW access, and a port of the system to UNIX and Windows-NT/95. (orig.)

  17. Architecture of SPIDER control and data acquisition system

    International Nuclear Information System (INIS)

    Luchetta, A.; Manduchi, G.; Taliercio, C.; Soppelsa, A.; Barbalace, A.; Paolucci, F.; Sartori, F.; Barbato, P.; Breda, M.; Capobianco, R.; Molon, F.; Moressa, M.; Polato, S.; Simionato, P.; Zampiva, E.

    2012-01-01

    The ITER Heating Neutral Beam injectors will be implemented in three steps: development of the ion source prototype, development of the full injector prototype, and, finally, construction of up to three ITER injectors. The first two steps will be carried out in the ITER neutral beam test facility under construction in Italy. The ion source prototype, referred to as SPIDER, which is currently in the development phase, is a complex experiment involving more than 20 plant units and operating with beam-on pulses lasting up to 1 h. As for control and data acquisition it requires fast and slow control (cycle time around 0.1 ms and 10 ms, respectively), synchronization (10 ns resolution), and data acquisition for about 1000 channels (analogue and images) with sampling frequencies up to tens of MS/s, data throughput up to 200 MB/s, and data storage volume of up to tens of TB/year. The paper describes the architecture of the SPIDER control and data acquisition system, discussing the SPIDER requirements and the ITER CODAC interfaces and specifications for plant system instrumentation and control.

  18. Data acquisition

    International Nuclear Information System (INIS)

    Clout, P.N.

    1982-01-01

    Data acquisition systems are discussed for molecular biology experiments using synchrotron radiation sources. The data acquisition system requirements are considered. The components of the solution are described including hardwired solutions and computer-based solutions. Finally, the considerations for the choice of the computer-based solution are outlined. (U.K.)

  19. Control and Data Acquisition System of the ATLAS Facility

    International Nuclear Information System (INIS)

    Choi, Ki-Yong; Kwon, Tae-Soon; Cho, Seok; Park, Hyun-Sik; Baek, Won-Pil; Kim, Jung-Taek

    2007-02-01

    This report describes the control and data acquisition system of an integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation) facility, which recently has been constructed at KAERI (Korea Atomic Energy Research Institute). The control and data acquisition system of the ATLAS is established with the hybrid distributed control system (DCS) by RTP corp. The ARIDES system on a LINUX platform which is provided by BNF Technology Inc. is used for a control software. The IO signals consists of 1995 channels and they are processed at 10Hz. The Human-Machine-Interface (HMI) consists of 43 processing windows and they are classified according to fluid system. All control devices can be controlled by manual, auto, sequence, group, and table control methods. The monitoring system can display the real time trend or historical data of the selected IO signals on LCD monitors in a graphical form. The data logging system can be started or stopped by operator and the logging frequency can be selected among 0.5, 1, 2, 10Hz. The fluid system of the ATLAS facility consists of several systems including a primary system to auxiliary system. Each fluid system has a control similarity to the prototype plant, APR1400/OPR1000

  20. The Nuclotron internal target control and data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Isupov, A.Yu., E-mail: isupov@moonhe.jinr.ru [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Krasnov, V.A.; Ladygin, V.P.; Piyadin, S.M.; Reznikov, S.G. [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation)

    2013-01-11

    The new control system of the Nuclotron (JINR, Dubna) internal target is described in both hardware and software aspects. The CAMAC hardware is based on the use of the standard CAMAC modules developed and manufactured at JINR. The internal target control and data acquisition (IntTarg CDAQ) system software is implemented using the ngdp framework under the Unix-like operating system (OS) FreeBSD to allow easy network distribution of the online data collected from internal target and accompanying detectors, as well as the internal target remote control.

  1. The design of the Hyperon Data Acquisition System

    International Nuclear Information System (INIS)

    Gee, C.N.P.

    1980-12-01

    A new Native-mode Data Acquisition system, running on a VAX 11/780, has been designed for the SPS Hyperon Experiments at CERN. The system incorporates a variable number of communicating processes running under VAX/VMS, including user-written monitoring processes. Event handling has been implemented into the CAMAC Driver, and facilities are provided for using a data buffer much larger than the System Maximum Working-set Size. A generalised debugging facility for non terminal-oriented processes is also supported. (author)

  2. Development of small and inexpensive digital data acquisition systems using a microcontroller-based approach.

    Science.gov (United States)

    Naivar, Mark A; Wilder, Mark E; Habbersett, Robert C; Woods, Travis A; Sebba, David S; Nolan, John P; Graves, Steven W

    2009-12-01

    Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD-based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers.

  3. Development of small and inexpensive digital data acquisition systems using a microcontroller-based approach†

    Science.gov (United States)

    Naivar, Mark A.; Wilder, Mark E.; Habbersett, Robert C.; Woods, Travis A.; Sebba, David S.; Nolan, John P.; Graves, Steven W.

    2014-01-01

    Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers. PMID:19852060

  4. Waste retrieval sluicing system data acquisition system acceptance test report

    International Nuclear Information System (INIS)

    Bevins, R.R.

    1998-01-01

    This document describes the test procedure for the Project W-320 Tank C-106 Sluicing Data Acquisition System (W-320 DAS). The Software Test portion will test items identified in the WRSS DAS System Description (SD), HNF-2115. Traceability to HNF-2115 will be via a reference that follows in parenthesis, after the test section title. The Field Test portion will test sensor operability, analog to digital conversion, and alarm setpoints for field instrumentation. The W-320 DAS supplies data to assist thermal modeling of tanks 241-C-106 and 241-AY-102. It is designed to be a central repository for information from sources that would otherwise have to be read, recorded, and integrated manually. Thus, completion of the DAS requires communication with several different data collection devices and output to a usable PC data formats. This test procedure will demonstrate that the DAS functions as required by the project requirements stated in Section 3 of the W-320 DAS System Description, HNF-2115

  5. Information management system breadboard data acquisition and control system.

    Science.gov (United States)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  6. The Tara control, monitoring, data acquisition, and analysis system

    International Nuclear Information System (INIS)

    Sullivan, J.D.; Gaudreau, M.P.J.; Blanter, B.

    1987-01-01

    Experiments at the MIT Tara Tandem Mirror utilize an integrated system for control, monitoring, data acquisition, physics analysis, and archiving. This system consists of two distinct parts with narrowly defined information interchange; one to provide automated control and real time monitoring of engineering functions and one to acquire, analyze, and display data for physics in near real time. Typical machine operation achieves a total cycle time of 3 to 8 minutes with 5 to 7 Mbytes of data stored and with --160 individual signals displayed in hardcopy on --10 pages

  7. Multifunctional data acquisition system based on USB and FPGA

    International Nuclear Information System (INIS)

    Huang Tuchen; Gong Hui; Shao Beibei

    2013-01-01

    A multifunctional data acquisition system based on USB and FPGA was developed. The system has four analog inputs digitalized by fast ADC. Based on flexibility of FPGA, different functions can be implemented such as waveform sampling, pulse counting, multi-channel pulse height analysis, and charge division readout process. The hardware communicates with host PC via USB interface. The Labview based user soft ware initializes the hardware, configures the running parameters, reads and processes the data as well as displays the result online. (authors)

  8. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  9. The Tara control, monitoring, data acquisition and analysis system

    International Nuclear Information System (INIS)

    Sullivan, J.D.; Gaudreau, M.P.J.; Blanter, B.

    1986-09-01

    Experiments at the MIT Tara Tandem Mirror utilize an integrated system for control, monitoring, data acquisition, physics analysis, and archiving. This system consists of two distinct parts with narrowly defined information interchange; one to provide automated control and real time monitoring of engineering functions and one to acquire, analyze, and display data for physics in near real time. Typical machine operation achieves a total cycle time of 3 to 8 minutes with 5 to 7 Mbytes of data stored and with ∼160 individual signals displayed in hardcopy on ∼10 pages

  10. IPNS distributed-processing data-acquisition system

    International Nuclear Information System (INIS)

    Haumann, J.R.; Daly, R.T.; Worlton, T.G.; Crawford, R.K.

    1981-01-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a major new user-oriented facility which has come on line for basic research in neutron scattering and neutron radiation damage. This paper describes the distributed-processing data-acquisition system which handles data collection and instrument control for the time-of-flight neutron-scattering instruments. The topics covered include the overall system configuration, each of the computer subsystems, communication protocols linking each computer subsystem, and an overview of the software which has been developed

  11. Data acquisition system for medium power neutral beam test facility

    International Nuclear Information System (INIS)

    Stewart, C.R. Jr.; Francis, J.E. Jr.; Hammons, C.E.; Dagenhart, W.K.

    1978-06-01

    The Medium Power Neutral Beam Test Facility at Oak Ridge National Laboratory was constructed in order to develop, test, and condition powerful neutral beam lines for the Princeton Large Torus experiment at Princeton Plasma Physics Laboratory. The data acquisition system for the test stand monitors source performance, beam characteristics, and power deposition profiles to determine if the beam line is operating up to its design specifications. The speed of the computer system is utilized to provide near-real-time analysis of experimental data. Analysis of the data is presented as numerical tabulation and graphic display

  12. Data acquisition system for PLT Neutral Beam Test Stand

    International Nuclear Information System (INIS)

    Francis, J.E. Jr.; Hammons, C.E.

    1977-01-01

    The PLT Neutral Beam Test Stand at Oak Ridge National Laboratory was constructed to test and condition powerful neutral beam sources for the Princeton Large Torus experiment at Princeton Plasma Physics Laboratory. The data acquisition system for the test stand monitors the beam characteristics and power output to determine if the beam is operating at its design specifications. The high speed of the computer system is utilized to provide near-real-time analysis of experimental data. The analysis of the data is presented as numerical tabulation and graphic display

  13. An Overview of Advanced Data Acquisition System (ADAS)

    Science.gov (United States)

    Mata, Carlos T.; Steinrock, T. (Technical Monitor)

    2001-01-01

    The paper discusses the following: 1. Historical background. 2. What is ADAS? 3. R and D status. 4. Reliability/cost examples (1, 2, and 3). 5. What's new? 6. Technical advantages. 7. NASA relevance. 8. NASA plans/options. 9. Remaining R and D. 10. Applications. 11. Product benefits. 11. Commercial advantages. 12. intellectual property. Aerospace industry requires highly reliable data acquisition systems. Traditional Acquisition systems employ end-to-end hardware and software redundancy. Typically, redundancy adds weight, cost, power consumption, and complexity.

  14. The research of data acquisition system for Raman spectrometer

    Science.gov (United States)

    Cui, Xiao; Guo, Pan; Zhang, Yinchao; Chen, Siying; Chen, He; Chen, Wenbo

    2011-11-01

    Raman spectrometer has been widely used as an identification tool for analyzing material structure and composition in many fields. However, Raman scattering echo signal is very weak, about dozens of photons at most in one laser plus signal. Therefore, it is a great challenge to design a Raman spectrum data acquisition system which could accurately receive the weak echo signal. The system designed in this paper receives optical signals with the principle of photon counter and could detect single photon. The whole system consists of a photoelectric conversion module H7421-40 and a photo counting card including a field programmable gate array (FPGA) chip and a PCI9054 chip. The module H7421-40 including a PMT, an amplifier and a discriminator has high sensitivity on wavelength from 300nm to 720nm. The Center Wavelength is 580nm which is close to the excitation wavelength (532nm), QE 40% at peak wavelength, Count Sensitivity is 7.8*105(S-1PW-1) and Count Linearity is 1.5MHZ. In FPGA chip, the functions are divided into three parts: parameter setting module, controlling module, data collection and storage module. All the commands, parameters and data are transmitted between FPGA and computer by PCI9054 chip through the PCI interface. The result of experiment shows that the Raman spectrum data acquisition system is reasonable and efficient. There are three primary advantages of the data acquisition system: the first one is the high sensitivity with single photon detection capability; the second one is the high integrated level which means all the operation could be done by the photo counting card; and the last one is the high expansion ability because of the smart reconfigurability of FPGA chip.

  15. Multisensory experiments and data acquisition systems on the meson facilities

    International Nuclear Information System (INIS)

    Bystritskij, V.M.

    2000-01-01

    The paper describes some of the multisensory experiments performed or being performed at the meson factories PSI (Switzerland), TRIUMF (Canada), LAMPF (USA), KEK (Japan), RAL (England) in order to investigate the fundamental processes in elementary particle physics. Designs of various detectors are briefly reviewed, the organizational ideology and the structure of the recording electronics and data acquisition systems for these experiments are considered. The ideology underlying the off-line analysis software is touched upon and the most important results of the investigations at meson factories are given

  16. The D0 level three data acquisition system

    International Nuclear Information System (INIS)

    Chapin, D.

    2004-01-01

    The DZERO experiment located at Fermilab has recently started RunII with an upgraded detector. The RunII physics program requires the Data Acquisition to readout the detector at a rate of 1 KHz. Events fragments, totaling 250 KB, are readout from approximately 60 front end crates and sent to a particular farm node for Level 3 Trigger processing. A scalable system, capable of complex event routing, has been designed and implemented based on commodity components: VMIC 7750 Single Board Computers for readout, a Cisco 6509 switch for data flow, and close to 100 Linux-based PCs for high-level event filtering

  17. Spent fuel test. Climax data acquisition system integration report

    International Nuclear Information System (INIS)

    Nyholm, R.A.; Brough, W.G.; Rector, N.L.

    1982-06-01

    The Spent Fuel Test - Climax (SFT-C) is a test of the retrievable, deep geologic storage of commercially generated, spent nuclear reactor fuel in granitic rock. Eleven spent fuel assemblies, together with 6 electrical simulators and 20 guard heaters, are emplaced 420 m below the surface in the Climax granite at the Nevada Test Site. On June 2, 1978, Lawrence Livermore National Laboratory (LLNL) secured funding for the SFT-C, and completed spent fuel emplacement May 28, 1980. This multi-year duration test is located in a remote area and is unattended much of the time. An extensive array of radiological safety and geotechnical instrumentation is deployed to monitor the test performance. A dual minicomputer-based data acquisition system collects and processes data from more than 900 analog instruments. This report documents the design and functions of the hardware and software elements of the Data Acquisition System and describes the supporting facilities which include environmental enclosures, heating/air-conditioning/humidity systems, power distribution systems, fire suppression systems, remote terminal stations, telephone/modem communications, and workshop areas. 9 figures

  18. Microprocessor based data acquisition system for Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Patwardhan, P.K.; Indurkar, V.S.

    1981-01-01

    A data acquisition system, for Moessbauer spectrometer and other probability distribution spectrum is described. This utilizes the advantages of incorporating a microcomputer for providing a flexible analytical capability and speed of hard wired MCS unit updating channel contents in DMA. Holbourn, Player and Woodhams have recently described a microprocessor controlled Moessbauer spectrometer where microprocessor performs the task of updating channel contents, requiring about 60 micro seconds in interrupt mode. This imposes restrictions on increasing the channel number and on increasing the velocity scan frequency in order to cover higher velocity ranges. The system described in this article performs data acquisition in faster direct memory access. It is a two module system, (1) MCS module (2) Microcomputer module, arranged around a common address, data and control buses. The microcomputer module has an access to the system data during flyback periods and can be programmed for the task of monitor on progess of experiment and as a manipulator of various control operations needed during experiment. The system firmware includes: (1) MONITOR (2) BLOCK-TRANSFER (3) DATA-SMOOTHING (4) DECIMAL-CONVERTER (5) MATH. The scope of this firmware is briefly described. (author)

  19. Development Of Data Acquisition Software For Centralized Radiation Monitoring System

    International Nuclear Information System (INIS)

    Nolida Yussup; Maslina Mohd Ibrahim; Mohd Fauzi Haris; Syirrazie Che Soh; Harzawardi Hasim; Azraf Azman; Mohd Ashhar Khalid

    2014-01-01

    Nowadays, with the growth of technology, many devices and equipment's can be connected to the network and internet to enable online data acquisition. Centralized radiation monitoring system utilizes a Local Area Network (LAN) as a communication media for data acquisition of the area radiation levels from radiation detectors in Malaysian Nuclear Agency (Nuclear Malaysia). The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software development on the system server that is responsible to acquire and record the area radiation readings from the detectors. Then the recorded readings are called in a web programming to be displayed on a web site. The readings with the time stamp are stored in the system database for query. Besides acquiring the area radiation levels in Nuclear Malaysia centrally, additional features such as data conversion from mR to μSv and line chart display are developed in the software for effective radiation level trend observation and studies. (author)

  20. Floating data acquisition system for microwave calorimeter measurements on MTX

    International Nuclear Information System (INIS)

    Sewall, N.R.

    1989-01-01

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 Series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs

  1. Floating data acquisition system for microwave calorimeter measurements on MTX

    International Nuclear Information System (INIS)

    Sewall, N.R.; Meassick, S.

    1989-01-01

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs

  2. Spent Fuel Test - Climax data acquisition system operations manual

    International Nuclear Information System (INIS)

    Nyholm, R.A.

    1983-01-01

    The Spent Fuel Test-Climax (SFT-C) is a test of the retrievable, deep geologic storage of commercially generated, spent nuclear reactor fuel in granite rock. Eleven spent fuel assemblies, together with 6 electrical simulators and 20 guard heaters, are emplaced 420 m below the surface in the Climax granite at the US Department of Energy Nevada Test Site. On June 2, 1978, Lawrence Livermore National Laboratory (LLNL) secured funding for the SFT-C, and completed spent fuel emplacement May 28, 1980. The multi-year duration test is located in a remote area and is unattended much of the time. An extensive array of radiological safety and geotechnical instrumentation is deployed to monitor the test performance. A dual minicomputer-based data acquisition system (DAS) collects and processes data from more than 900 analog instruments. This report documents the software element of the LLNL developed SFT-C Data Acquisition System. It defines the operating system and hardware interface configurations, the special applications software and data structures, and support software

  3. Isolated data acquisition system for high voltage applications

    International Nuclear Information System (INIS)

    Waitz, A.; Donaldson, A.

    1985-06-01

    This report describes the design and operation of a microcomputer controlled system for acquisition of both analog and binary data within the high voltage stages of a linac modulator. The system is comprised of a microprocessor Controller which communicates with the remote data Acquisition circuits via an optical bus. The bus, which uses a 1 MHz Manchester II format, is configured as a loop, starting at the Controller, daisy-chaining the remote cards and terminating back at the Controller. Upon receiving a linac timing pulse, the Controller sends addressed commands to the individual remote cards and receives data back. It then passes this data to the linac control system through a Multibus connection. Each remote circuit can return 16 binary sense and 7 (12 bit) analog parameters within 270 us. This speed is possible because of a pipelined design where one word is transmitted while another is being converted. A data conversion cycle is initiated when a remote data acquisition card receives the proper command and address from the controller

  4. Low cost open data acquisition system for biomedical applications

    Science.gov (United States)

    Zabolotny, Wojciech M.; Laniewski-Wollk, Przemyslaw; Zaworski, Wojciech

    2005-09-01

    In the biomedical applications it is often necessary to collect measurement data from different devices. It is relatively easy, if the devices are equipped with a MIB or Ethernet interface, however often they feature only the asynchronous serial link, and sometimes the measured values are available only as the analog signals. The system presented in the paper is a low cost alternative to commercially available data acquisition systems. The hardware and software architecture of the system is fully open, so it is possible to customize it for particular needs. The presented system offers various possibilities to connect it to the computer based data processing unit - e.g. using the USB or Ethernet ports. Both interfaces allow also to use many such systems in parallel to increase amount of serial and analog inputs. The open source software used in the system makes possible to process the acquired data with standard tools like MATLAB, Scilab or Octave, or with a dedicated, user supplied application.

  5. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  6. Data-acquisition systems for the present and the future

    International Nuclear Information System (INIS)

    Drobnis, D.D.

    1982-09-01

    Basic components of today's acquisition systems are surveyed. These include front-end tools such as microprocessors, programmable controllers, and CAMAC interfaces. Some key concepts in large central real-time systems are examined: Hardware and Software architecture, and data base structure. Some trends in present data acquisition system design are analyzed, including increasing distribution of system functions and expansion to hierarchical multi-processor netowrks. With the evolution of microprocessors, front-end intelligence is growing into front-end computing power. Real-time host systems are becoming increasingly sophisticated human interface and data base management tools, with increasingly complex operating systems, and increasing amounts of memory, mass storage, and computing power. And the ultimate analysis of plasma data is becoming increasingly sophisticated

  7. Modeling Resource Utilization of a Large Data Acquisition System

    CERN Document Server

    AUTHOR|(SzGeCERN)756497; The ATLAS collaboration; Garcia Garcia, Pedro Javier; Vandelli, Wainer; Froening, Holger

    2017-01-01

    The ATLAS 'Phase-II' upgrade, scheduled to start in 2024, will significantly change the requirements under which the data-acquisition system operates. The input data rate, currently fixed around 150 GB/s, is anticipated to reach 5 TB/s. In order to deal with the challenging conditions, and exploit the capabilities of newer technologies, a number of architectural changes are under consideration. Of particular interest is a new component, known as the Storage Handler, which will provide a large buffer area decoupling real-time data taking from event filtering. Dynamic operational models of the upgraded system can be used to identify the required resources and to select optimal techniques. In order to achieve a robust and dependable model, the current data-acquisition architecture has been used as a test case. This makes it possible to verify and calibrate the model against real operation data. Such a model can then be evolved toward the future ATLAS Phase-II architecture. In this paper we introduce the current ...

  8. Modelling Resource Utilization of a Large Data Acquisition System

    CERN Document Server

    Santos, Alejandro; The ATLAS collaboration

    2017-01-01

    The ATLAS 'Phase-II' upgrade, scheduled to start in 2024, will significantly change the requirements under which the data-acquisition system operates. The input data rate, currently fixed around 150 GB/s, is anticipated to reach 5 TB/s. In order to deal with the challenging conditions, and exploit the capabilities of newer technologies, a number of architectural changes are under consideration. Of particular interest is a new component, known as the Storage Handler, which will provide a large buffer area decoupling real-time data taking from event filtering. Dynamic operational models of the upgraded system can be used to identify the required resources and to select optimal techniques. In order to achieve a robust and dependable model, the current data-acquisition architecture has been used as a test case. This makes it possible to verify and calibrate the model against real operation data. Such a model can then be evolved toward the future ATLAS Phase-II architecture. In this paper we introduce the current ...

  9. A microprocessor-based power control data acquisition system

    International Nuclear Information System (INIS)

    Greenberg, S.

    1982-10-01

    The project reported deals with one of the aspects of power plant control and management. In order to perform optimal distribution of power and load switching, one has to solve a specific optimization problem. In order to solve this problem one needs to collect current and power expenditure data from a large number of channels and have them processed. This particular procedure is defined as data acquisition and it constitutes the main topic of this project. A microprocessor-based data acquisition system for power management is investigated and developed. The current and power data of about 100 analog channels are sampled and collected in real-time. These data are subsequently processed to calculate the power factor (cos phi) for each channel and the maximum demand. The data is processed by an AMD 9511 Arithmetic Processing Unit and the whole system is controlled by an Intel 8080A CPU. All this information is then transfered to a universal computer through a synchronized communication channel. The optimization computations would be performed by the high level computer. Different ways of performing the search of data over a large number of channels have been investigated. A particular solution to overcome the gain and offset drift of the A/D converter, using software, has been proposed. The 8080A supervises the collection and routing of data in real time, while the 9511 performs calculation, using these data. (Author)

  10. A DSP controlled data acquisition system for CELSIUS

    International Nuclear Information System (INIS)

    Bengtsson, M.; Lofnes, T.; Ziemann, V.

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities

  11. A DSP controlled data acquisition system for CELSIUS

    CERN Document Server

    Bengtsson, M; Ziemann, Volker

    2000-01-01

    We describe a data acquisition system based on two 10 MHz A/D-converters, a SHARC Digital Signal Processor (DSP), and a digital synthesizer used for triggering the A/D-converters. The temporal macrostructure of the data acquisition can be determined by external triggers or by timer interrupts from the DSP. In this way up to two million samples can be stored in DSP external memory. The samples are analyzed by directly fast Fourier transforming blocks of samples. In another mode we use software-based downmixing and filtering techniques to increase the resolution and zoom in on a small frequency band. Spectra of up to 5 MHz can be manipulated and displayed as waterfall plots or spectral maps on the host computer directly. Moreover, signals of up to 70 MHz can be analyzed by undersampling techniques. We use this system to analyze Schottky spectra from electron-cooled ion beams in CELSIUS and report drag rate measurements and observations of instabilities.

  12. The Resource Manager the ATLAS Trigger and Data Acquisition System

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00210579; The ATLAS collaboration; Avolio, Giuseppe; Lehmann Miotto, Giovanna; Soloviev, Igor

    2017-01-01

    The Resource Manager is one of the core components of the Data Acquisition system of the ATLAS experiment at the LHC. The Resource Manager marshals the right for applications to access resources which may exist in multiple but limited copies, in order to avoid conflicts due to program faults or operator errors. The access to resources is managed in a manner similar to what a lock manager would do in other software systems. All the available resources and their association to software processes are described in the Data Acquisition configuration database. The Resource Manager is queried about the availability of resources every time an application needs to be started. The Resource Manager’s design is based on a client-server model, hence it consists of two components: the Resource Manager “server” application and the “client” shared library. The Resource Manager server implements all the needed functionalities, while the Resource Manager client library provides remote access to the “server” (i.e....

  13. An improved data acquisition system at the Saskatchewan Accelerator Laboratory

    International Nuclear Information System (INIS)

    Norum, W.E.

    1994-01-01

    An improved data acquisition system has been in service at the Saskatchewan Accelerator Laboratory for the past 14 months. The system has shown itself to be reliable and easy to use having collected over 800 gigabytes of data for a number of experiments. The system is based on a VME front end computer acquiring data from CAMAC and FASTBUS modules and forwarding the data via an Ethernet connection to an acquisition workstation for archiving and on-line analysis. A multiprocessor real-time operating system in the front end computer makes increasing the performance of the system a simple matter of adding an additional processor to the VME chassis. Experimenters need only write a high-level description of their experiment which is transformed into a C program for the front end computer by a translation program. Special requirements are met by facilities for direct inclusion of user C or FORTRAN code

  14. A multi-channel microcomputer data acquisition system

    International Nuclear Information System (INIS)

    Loureiro, J.S.

    1987-01-01

    A data acquisition system was developed in order to transfer automatically to a 64 kb microcomputer the data generated by a nuclear spectroscopy system in a multichannel analyser. The data in the memory are stored in a floppy disk and will be further used as data entry for any spectrum analysis program, eliminating the tedious work of manually digitizing the spectrum and the possible mistakes associated with it. The developed system connected a POLYMAX 201 DP microcomputer, under CP/M operational system, to a NUCLEAR DATA MODEL ND-65 multichannel analyser and was planned for either local spectrum analysis in the microcomputer using a simplified program, or remote analysis in a mainframe using the sophisticated analysis program SAMPO. With the present system, the time spent between printing out of the 4096 channels with the multichannel analyser printer and its corresponding introduction in the analysis program has been reduced from about 6 hours to less than 2 minutes. (author)

  15. The ATLAS Data Acquisition System LHC Run 2

    CERN Document Server

    Panduro Vazquez, William; The ATLAS collaboration

    2016-01-01

    The LHC has been providing pp collisions with record luminosity and energy since the start of Run 2 in 2015. In the ATLAS experiment the Trigger and Data Acquisition system has been upgraded to deal with the increased event rates. The dataflow element of the system is distributed across hardware and software and is responsible for buffering and transporting event data from the Readout system to the High Level Trigger and on to event storage. The dataflow system has been reshaped in order benefit from technological progress and to maximize the flexibility and efficiency of the data selection process. The updated dataflow system is radically different from the previous implementation both in terms of architecture and performance. The previous two level software filtering architecture, known as L2 and the Event Filter, have been merged with the Event Builder function into a single process, performing incremental data collection and analysis. This design has many advantages, among which are: radical simplificatio...

  16. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  17. Work of plant data acquisition system for 'MONJU'

    International Nuclear Information System (INIS)

    Hashimoto, Daisuke; Komatsu, Keiichi; Eguchi, Kenji; Morizono, Koji

    2007-01-01

    The fast breeder reactor 'MONJU' (hereafter 'MONJU') is equipped with the system called 'MONJU Integrated Data Acquisition System (MIDAS)' to effectively acquire, accumulate and analyze relevant real-plant process data gathered from the system start-up test. At present, 'MONJU' has been suspended due to a sodium leak accident that occurred in 1995. However, the main part of remodeling construction to prevent sodium leaks was completed in May, 2007 and 'MONJU' is highly expected to resume its operations, stepping into the practical testing phase. In this situation, 'MIDAS' has been replaced with an upgraded version before the system start-up test was resumed. This paper describes overview of the new 'MIDAS' system. (author)

  18. LOFT data acquisition and visual display system (DAVDS) presentation program

    International Nuclear Information System (INIS)

    Bullock, M.G.; Miyasaki, F.S.

    1976-03-01

    The Data Acquisition and Visual Display System (DAVDS) at the Loss-of-Fluid Test Facility (LOFT) has 742 data channel recording capability of which 576 are recorded digitally. The purpose of this computer program is to graphically present the data acquired and/or processed by the LOFT DAVDS. This program takes specially created plot data buffers of up to 1024 words and generates time history plots on the system electrostatic printer-plotter. The data can be extracted from two system input devices: Magnetic disk or digital magnetic tape. Versatility has been designed in the program by providing the user three methods of scaling plots: Automatic, control record, and manual. Time required to produce a plot on the system electrostatic printer-plotter varies from 30 to 90 seconds depending on the options selected. The basic computer and program details are described

  19. Fourth Data Challenge for the ALICE data acquisition system

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    The ALICE experiment will study quark-gluon plasma using beams of heavy ions, such as those of lead. The particles in the beams will collide thousands of times per second in the detector and each collision will generate an event containing thousands of charged particles. Every second, the characteristics of tens of thousands of particles will have to be recorded. Thus, to be effective, the data acquisition system (DAQ) must meet extremely strict performance criteria. To this end, the ALICE Data Challenges entail step-by-step testing of the DAQ with existing equipment that is sufficiently close to the final equipment to provide a reliable indication of performance. During the fourth challenge, in 2002, a data acquisition rate of 1800 megabytes per second was achieved by using some thirty parallel-linked PCs running the specially developed DATE software. During the final week of tests in December 2002, the team also tested the Storage Tek linear magnetic tape drives. Their bandwidth is 30 megabytes per second a...

  20. Distributed CAN-BUS-based data acquisition system

    International Nuclear Information System (INIS)

    Orekhov, D.I.; Chepurnov, A.S.; Majmistov, D.I.; Sabel'nikov, A.A.

    2007-01-01

    A distributed remote-control system for large nuclear physical setups is intended to collect, store, and analyze data arriving from detecting devices and to visualize them via the WEB. The system uses the CAN industrial data transmission network and the DeviceNet high-level protocol. The hardware part is the set of controllers, which convert signals of the detecting devices into a frequency and transmit them in the digital form via the CAN network to the host computer. The software realizes the DeviceNet protocol stack, which ensures the data acquisition and transmission. The user interface is based on dynamic WEB pages. The system is used for monitoring dark noises of photomultiplier tubes in the BOREXINO neutrino detector (Italy) [ru

  1. Microcomputer-controlled ultrasonic data acquisition system. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, W.A. Jr.

    1978-11-01

    The large volume of ultrasonic data generated by computer-aided test procedures has necessitated the development of a mobile, high-speed data acquisition and storage system. This approach offers the decided advantage of on-site data collection and remote data processing. It also utilizes standard, commercially available ultrasonic instrumentation. This system is controlled by an Intel 8080A microprocessor. The MCS80-SDK microcomputer board was chosen, and magnetic tape is used as the storage medium. A detailed description is provided of both the hardware and software developed to interface the magnetic tape storage subsystem to Biomation 8100 and Biomation 805 waveform recorders. A boxcar integrator acquisition system is also described for use when signal averaging becomes necessary. Both assembly language and machine language listings are provided for the software.

  2. New Communication Network Protocol for a Data Acquisition System

    Science.gov (United States)

    Uchida, T.; Fujii, H.; Nagasaka, Y.; Tanaka, M.

    2006-02-01

    An event builder based on communication networks has been used in high-energy physics experiments, and various networks have been adopted, for example, IEEE 802.3 (Ethernet), asynchronous transfer mode (ATM), and so on. In particular, Ethernet is widely used because its infrastructure is very cost effective. Many systems adopt standard protocols that are designed for a general network. However, in the case of an event builder, the communication pattern between stations is different from that in a general network. The unique communication pattern causes congestion, and thus makes it difficulty to quantitatively design the network. To solve this problem, we have developed a simple network protocol for a data acquisition (DAQ) system. The protocol is designed to keep the sequence of senders so that no congestion occurs. We implemented the protocol on a small hardware component [a field programmable gate array (FPGA)] and measured the performance, so that it will be ready for a generic DAQ system

  3. Data Acquisition in a Manoeuver Auto-negotiation System

    Directory of Open Access Journals (Sweden)

    Joanna Szlapczynska

    2015-09-01

    Full Text Available Typical approach to collision avoidance systems with artificial intelligence support is that such systems assume a central communication and management point (such as e.g. VTS station, usually located on shore. This approach is, however, not applicable in case of an open water encounter. Thus, recently a new approach towards collision avoidance has been proposed, assuming that all ships in the encounter, either restricted or open water, communicate with each other and negotiate their maneuvers, without involving any outer management or communication center. Usually the negotiation process is driven by the collision avoidance software and called auto-negotiation. This paper elaborates on data acquisition problem in case of the maneuver auto-negotiation. It focuses on ships' initialization in the system and data gathering.

  4. The data acquisition system (DAS) for the improved CERN SC

    CERN Document Server

    Beger, H; Fiebig, A; Schroot, H

    1975-01-01

    A digital data acquisition system (DAS) based on a minicomputer is described which registers the failure sequences in various equipment areas of the CERN synchrocyclotron (henceforward referred to as the SC). The avalanches of failure signals which occur from time to time are tapped from the alarm/security systems, time-resolved to 10 msec and recorded on a printer in order to aid SC failure diagnosis. The mechanisms of the DAS and its relation to the SC equipment are explained in some detail. All programs were constructed at assembler language level for speed and for ease of on-line program maintenance. The alarm sequences recorded have been of considerable help during the running in of the new radiofrequency system. Now that the new SC is operational, the DAS furnishes useful data from several equipment areas to the operators and engineers.

  5. High speed, locally controlled data acquisition system for TFTR

    International Nuclear Information System (INIS)

    Feng, H.K.; Bradish, G.J.

    1983-01-01

    A high speed, locally controlled, data acquisition and transmission system has been developed by the CICADA (Central Instrumentation Control and Data Acquisition) Group for extracting certain timecritical data during a TFTR pulse and passing it to the control room, 1000 feet distant, to satisfy realtime requirements of frequently sampled variables. The system is designed to utilize any or all of the standard CAMAC (Computer Automated Measurement and Control) modules now employed on the CAMAC links for retrieval of the main body of data, but to operate them in a much faster manner than in a standard CAMAC system. To do this, a pre-programmable ROM sequencer is employed as a controller to transmit commands to the modules at intervals down to one microsecond, replacing the usual CAMAC dedicated computer, and increasing the command rate by an order of magnitude over what could be sent down a Branch Highway. Data coming from any number of channels originating within a single CAMAC ''crate'' is then time-multiplexed and transmitted over a single conductor pair in bi-phase at a 2.5 MHz bit rate using Manchester coding techniques. Benefits gained from this approach include: Reduction in the number of conductors required, elimination of line-to-line skew found in parallel transmission systems, and the capability of being transformer coupled or transmitted over a fiber optic cable to avoid safety hazards and ground loops. The main application for this system so far has been as the feedback path in this closed loop control of currents through the Tokamak's field coils. The paper will treat the system's various applications

  6. The Resource Manager the ATLAS Trigger and Data Acquisition System

    Science.gov (United States)

    Aleksandrov, I.; Avolio, G.; Lehmann Miotto, G.; Soloviev, I.

    2017-10-01

    The Resource Manager is one of the core components of the Data Acquisition system of the ATLAS experiment at the LHC. The Resource Manager marshals the right for applications to access resources which may exist in multiple but limited copies, in order to avoid conflicts due to program faults or operator errors. The access to resources is managed in a manner similar to what a lock manager would do in other software systems. All the available resources and their association to software processes are described in the Data Acquisition configuration database. The Resource Manager is queried about the availability of resources every time an application needs to be started. The Resource Manager’s design is based on a client-server model, hence it consists of two components: the Resource Manager “server” application and the “client” shared library. The Resource Manager server implements all the needed functionalities, while the Resource Manager client library provides remote access to the “server” (i.e., to allocate and free resources, to query about the status of resources). During the LHC’s Long Shutdown period, the Resource Manager’s requirements have been reviewed at the light of the experience gained during the LHC’s Run 1. As a consequence, the Resource Manager has undergone a full re-design and re-implementation cycle with the result of a reduction of the code base by 40% with respect to the previous implementation. This contribution will focus on the way the design and the implementation of the Resource Manager could leverage the new features available in the C++11 standard, and how the introduction of external libraries (like Boost multi-container) led to a more maintainable system. Additionally, particular attention will be given to the technical solutions adopted to ensure the Resource Manager could effort the typical requests rates of the Data Acquisition system, which is about 30000 requests in a time window of few seconds coming from more

  7. Application of tape unit in data acquisition system and its maintenance and trouble shoot

    International Nuclear Information System (INIS)

    Xing Jianping; Qian Xicheng

    1995-01-01

    Application of magnetic tape unit in data acquisition system of DEC computer imported from German and its maintenance as well as trouble shoot is described. The system is used for nuclear data acquisition and processing

  8. CORBA technology in reengineering the FTU data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Bertocchi, A; Buceti, G; Centioli, C; Di Muzio, D; Iannone, F.; Panella, M; Vitale, V

    2002-06-01

    In its early stages, Frascati tokamak upgrade DAS was essentially devoted to acquiring data from experiments in CAMAC standard, using a software system (code and database) entirely written by domestic professionals. In 15 years of life DAS has been growing in size and complexity, still preserving its original structure; at the same time new standards were introduced (VME, PCI) to take into account users' ever increasing demands for amount of data and acquisition frequency with which the existing code couldn't cope. Moreover, machines were getting old and the maintenance became troublesome. Finally, the data archive porting to Unix has definitely shown that the DAS system was ageing and a thorough redesign was needed. The system we are planning to introduce is founded on a standard CORBA bus: (i) to integrate heterogeneous platforms and define a standard layer for interactions between the different acquisition units; (ii) to grant, with open source tools (MySql) and interfaces (Html and Java), unified access to hardware and software configuration data. So, a dedicated PC server, connected via a suitable PCI serial highway driver card, will perform the CAMAC access for all the clients interacting through the CORBA layer. Up to now we have successfully tested CAMAC access, and we designed an acquisition unit, which will be the building block of the new system. The next step will be migrating to Alpha/VMS the software related to CAMAC data acquisition, which has been so far the cornerstone of the whole DAS; it will be completely redesigned to fit the 'acquisition unit' paradigm we have defined. Finally we will have a fully distributed data acquisition system with VME (at present six such units have been operating since 1999) and PCI stations, an Alpha/VMS client of the CAMAC/PC server and any possible platform interacting through a CORBA bus for getting data configuration, synchronisation and data archiving.

  9. CORBA technology in reengineering the FTU data acquisition system

    International Nuclear Information System (INIS)

    Bertocchi, A.; Buceti, G.; Centioli, C.; Di Muzio, D.; Iannone, F.; Panella, M.; Vitale, V.

    2002-01-01

    In its early stages, Frascati tokamak upgrade DAS was essentially devoted to acquiring data from experiments in CAMAC standard, using a software system (code and database) entirely written by domestic professionals. In 15 years of life DAS has been growing in size and complexity, still preserving its original structure; at the same time new standards were introduced (VME, PCI) to take into account users' ever increasing demands for amount of data and acquisition frequency with which the existing code couldn't cope. Moreover, machines were getting old and the maintenance became troublesome. Finally, the data archive porting to Unix has definitely shown that the DAS system was ageing and a thorough redesign was needed. The system we are planning to introduce is founded on a standard CORBA bus: (i) to integrate heterogeneous platforms and define a standard layer for interactions between the different acquisition units; (ii) to grant, with open source tools (MySql) and interfaces (Html and Java), unified access to hardware and software configuration data. So, a dedicated PC server, connected via a suitable PCI serial highway driver card, will perform the CAMAC access for all the clients interacting through the CORBA layer. Up to now we have successfully tested CAMAC access, and we designed an acquisition unit, which will be the building block of the new system. The next step will be migrating to Alpha/VMS the software related to CAMAC data acquisition, which has been so far the cornerstone of the whole DAS; it will be completely redesigned to fit the 'acquisition unit' paradigm we have defined. Finally we will have a fully distributed data acquisition system with VME (at present six such units have been operating since 1999) and PCI stations, an Alpha/VMS client of the CAMAC/PC server and any possible platform interacting through a CORBA bus for getting data configuration, synchronisation and data archiving

  10. Experiences at HERA with the H1 data acquisition system

    International Nuclear Information System (INIS)

    Haynes, W.J.

    1992-09-01

    The recently commissioned HERA collider provides a significant pointer to the problems that have to be surmounted in data acquisition systems at the next generation of hadron machines. With bunch crossings, between 30 GeV electrons and 820 GeV protons, 96 nanoseconds apart, the H1 experiment illustrates the application of sophisticated pipelining solutions in the readout of several hundred thousand electronic channels. A modular, multiprocessor design structure emphasis the architectural concepts necessary to cope with large data throughput and yet remain flexible enough to exploit ongoing technological advances in both hardware and software. The range of techniques implemented will be surveyed, covering various digitisation solutions at the front-end through to embedded microprocessor arrays in standard busses controlled by graphics-based stations executing object- orientated code. The experiences gained in developing such a system are also discussed. (orig.)

  11. Digital control and data acquisition system for the QUIET experiment

    International Nuclear Information System (INIS)

    Bogdan, Mircea; Kapner, Dan; Samtleben, Dorothea; Vanderlinde, Keith

    2007-01-01

    We present the Digital Control and Data Acquisition System (DCDAQ) for Phase I of the Q/U Imaging Experiment (QUIET), arrays of 91 W-band and 19 Q-band receivers, placed on 1.4 m telescopes, in Chajnantor, Chile to measure the polarization of the cosmic microwave background. QUIET uses custom-built electronics boards that control and monitor its polarimeters. Each of these boards is digitally addressable, so that the DCDAQ can set and monitor any of the 1600 biases needed to operate the 91 receivers. The DCDAQ consists of a controller and up to 13 custom-made 32-channel ADC cards. Local FPGAs allow real-time data processing for each channel. This immediate data reduction is necessary, as it is planned to scale this technology beyond Phase I. The DCDAQ system is implemented with this future in mind and can easily be scaled to operate 1000 receivers

  12. Data Acquisition and Transmission System for Building Energy Consumption Monitoring

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2013-01-01

    Full Text Available Building energy consumption monitoring and management system have been developed widely in China in order to gain the real-time data of energy consumption in buildings for analyzing it in the next state work. This paper describes a low-cost and small-sized collector based on the STM32 microcontroller, which can be placed in a building easily to implement the work of data acquisition, storage, and transmission. The collector gathers the electricity, water, heat, and energy consumption data through the RS485 field bus and stores the data into an SD card with mass storage, finally, using Internet to finish the communication and transmission to data server through TCP protocol. The collector has been used in application for two years, and the results show that the system is reliable and stable.

  13. The ATLAS Data Acquisition system in LHC Run 2

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00042480; The ATLAS collaboration

    2017-01-01

    The LHC has been providing pp collisions with record luminosity and energy since the start of Run 2 in 2015. The Trigger and Data Acquisition system of the ATLAS experiment has been upgraded to deal with the increased performance required by this new operational mode. The dataflow system and associated network infrastructure have been reshaped in order to benefit from technological progress and to maximize the flexibility and efficiency of the data selection process. The new design is radically different from the previous implementation both in terms of architecture and performance, with the previous two-level structure merged into a single processing farm, performing incremental data collection and analysis. In addition, logical farm slicing, with each slice managed by a dedicated supervisor, has been dropped in favour of global management by a single farm master operating at 100 kHz. This farm master has also been integrated with a new software-based Region of Interest builder, replacing the previous VMEbus...

  14. The reliability data acquisition system in PWR nuclear power plants

    International Nuclear Information System (INIS)

    Lienart, P.

    1984-01-01

    In April 1978, Electricite de France put a reliability data acquisition system (SRDF) into operation at its two nuclear power plant sites: Fessenheim and Bugey. In the light of the experience acquired and the advantages offered by such a data bank, this system has been progressively extended since 1982 to cover the entire PWR network. The SRDF was originally designed for the follow-up of 4000 items of equipment per pair of units. However, the various difficulties encountered in gathering data made it necessary - in order to safeguard the quality of the information - to reduce this number initially to 800 major mechanical or electromechanical items of equipment designed to ensure the safety or availability of the units. Subsequently, an increase to 1100 was possible. The SRDF consists of a centralized information bank linked by telephone to the various nuclear sites. The software enables the data-acquisition cards to be introduced, modified or deleted. Any user can gain access to the bank by simply making queries in real time. The quality of the acquisition and processing of the data depend on a list of equipment confined to essential operational systems and on a card design combining, as far as possible, the precision and accessibility of the data. A method of logical failure analysis has also been devised, its main purposes being to provide the following: (1) aid to card instruction; (2) an easier way of checking the uniformity of information concerning a failure; and (3) compatibility between the instructions and analysis of data, thereby facilitating development of the data-processing program. (author)

  15. Data acquisition system for light-ion irradiation creep experiment

    International Nuclear Information System (INIS)

    Hendrick, P.L.; Whitaker, T.J.

    1979-07-01

    Software was developed for a PDP11V/03-based data acquisition system to support the Light-Ion Irradiation Creep Experiment installed at the University of Washington Tandem Van de Graaff Accelerator. The software consists of a real-time data acquisition and storage program, DAC04, written in assembly language. This program provides for the acquisition of up to 30 chennels at 100 Hz, data averaging before storage on disk, alarming, data table display, and automatic disk switching. All analog data are acquired via an analog-to-digital converter subsystem having a resolution of 14 bits, a maximum throughput of 20 kHz, and an overall system accuracy of +-0.01%. These specifications are considered essential for the long-term measurement of irradiation creep strains and temperatures during the light-ion bombardment of irradiation creep specimens. The software package developed also contains a collection of FORTRAN programs designed to monitor a test while in progress. These programs use the foreground/background feature of the RT-11 operating system. The background programs provide a variety of services. The program, GRAFTR, allows transient data (i.e., prior to averaging) to be graphed at the graphics terminal. The program, GRAFAV, allows averaged data to be read from disk and displayed graphically at the terminal. The program, TYPAV, reads averaged data from disk and displays it at the terminal in tabular form. Other programs allow text messages to be written to disk, read from disk, and allow access to DAC04 initialization data. 5 figures, 18 tables

  16. Development of a supervisory control and data acquisitioning system

    International Nuclear Information System (INIS)

    Kamboh, A.M.; Fakhar, H.A.; Rafiq, G.; Kazmi, S.R.

    2004-01-01

    This paper describes a Supervisory Control and Data Acquisitioning system called SCADA that we have developed at NUST. This research is aimed at the development of a network where a central Control Server extends bidirectional data exchange capability to hundreds of geographically remote sensors and actuators spread over a distance greater than 3 Km. Several battery-driven handheld terminals called Remote Terminal Units (RTU) have been designed to provide both wired and wireless connectivity between sensors and the network, also adding limited mobility to the sensors. Simple transceivers give the RTUs wireless access to network. The Human-Machine Intel (HMI) for the RTUs and the Server have been provided. A repeater has also been designed to increase the number of RTUs connected, and the maximum allowed distance between units and the server. The wired network gives several times faster connectivity than the wireless network, in addition to the larger area covered, but at the cost of mobility. (author)

  17. OLDASS: On-line data acquisition system at SF cyclotron

    International Nuclear Information System (INIS)

    Omata, Kazuo; Yasue, Masaharu; Hamagaki, Hideki

    1982-01-01

    The on-line data acquisition system in the Institute for Nuclear Study, the University of Tokyo, is composed of 2 systems of Fujitsu mini-computer PFU-400 for data processing at the high energy synchrotron and one system of that computer for low energy cyclotron as terminals, the host computer being M 180 II AD of the same company. This system has been developed to have the features of being the on-line system capable of following the improvement of host computer performance, being capable of developing the on-line programmes of other experimenting groups in parallel with batch jobs or the operation of the on-line system, and capable of developing programmes using FORTRAN. The result of about 220 KB/s was obtained for the data transfer rate between the programmes of the host computer and terminals, and this fulfilled the aimed performance. The terminal system on the low energy side is provided with an ADC interface and a display interface specified particularly in addition to the miniature computer PFU400 and standard I/O devices of the manufacture. The accumulating type graphic display of the I/O devices can be switched to be connected to the host computer, and immediately displays the results transferred to the host computer and analyzed. Hard copy is also available. The above hardware and software are explained. The on-line system insures 80 K bytes of the total memory of 224 K bytes for data area. (Wakatsuki, Y.)

  18. Design of data acquisition system for GEM detector

    International Nuclear Information System (INIS)

    Lu Jianliang; Chen Ziyu; Shen Ji; Jin Xi

    2011-01-01

    It describes the design and realization of the USB 2.0 high speed data acquisition devise which is used in the readout electronics of the GEM (gas electron multiplier) detector. By using of the USB Microcontroller EZ-USB FX2 CY7C68013A, high speed ADC and FPGA, high-speed data rate of data acquisition and transmission was realized. The data rate reaches to 20 MByte/s, meeting the requirements of data acquisition and transmission of the detector. (authors)

  19. Efficient network monitoring for large data acquisition systems

    International Nuclear Information System (INIS)

    Savu, D.O.; Martin, B.; Al-Shabibi, A.; Sjoen, R.; Batraneanu, S.M.; Stancu, S.N.

    2012-01-01

    Though constantly evolving and improving, the available network monitoring solutions have limitations when applied to the infrastructure of a high speed realtime data acquisition (DAQ) system. DAQ networks are particular computer networks where experts have to pay attention to both individual subsections as well as system wide traffic flows while monitoring the network. The ATLAS Network at the Large Hadron Collider (LHC) has more than 200 switches interconnecting 3500 hosts and totaling 8500 high speed links. The use of heterogeneous tools for monitoring various infrastructure parameters, in order to assure optimal DAQ system performance, proved to be a tedious and time consuming task for experts. To alleviate this problem we used our networking and DAQ expertise to build a flexible and scalable monitoring system providing an intuitive user interface with the same look and feel irrespective of the data provider that is used. Our system uses custom developed components for critical performance monitoring and seamlessly integrates complementary data from auxiliary tools, such as NAGIOS, information services or custom databases. A number of techniques (e.g. normalization, aggregation and data caching) were used in order to improve the user interface response time. The end result is a unified monitoring interface, for fast and uniform access to system statistics, which significantly reduced the time spent by experts for ad-hoc and post-mortem analysis. (authors)

  20. The ATLAS Data Acquisition System in LHC Run 2

    Science.gov (United States)

    Panduro Vazquez, William; ATLAS Collaboration

    2017-10-01

    The LHC has been providing pp collisions with record luminosity and energy since the start of Run 2 in 2015. The Trigger and Data Acquisition system of the ATLAS experiment has been upgraded to deal with the increased performance required by this new operational mode. The dataflow system and associated network infrastructure have been reshaped in order to benefit from technological progress and to maximize the flexibility and efficiency of the data selection process. The new design is radically different from the previous implementation both in terms of architecture and performance, with the previous two-level structure merged into a single processing farm, performing incremental data collection and analysis. In addition, logical farm slicing, with each slice managed by a dedicated supervisor, has been dropped in favour of global management by a single farm master operating at 100 kHz. This farm master has also been integrated with a new software-based Region of Interest builder, replacing the previous VMEbus-based system. Finally, the Readout system has been completely refitted with new higher performance, lower footprint server machines housing a new custom front-end interface card. Here we will cover the overall design of the system, along with performance results from the start-up phase of LHC Run 2.

  1. CAMAC data acquisition system based on micro VAXII

    International Nuclear Information System (INIS)

    Yin Xijin; Shen Cuihua; Bai Xiaowei; Li Weisheng

    1993-01-01

    The CAMAC data acquisition system based on Micro VAXII Computer provides high-speed, Zero-suppressed, and 256-parameter CAMAC acquisition. It consists of three parts: control logic unit, CAMAC readout system and host computer system. When the control logical unit is triggered by external electronic selection signal, it produces a pilot signal to keep all of the parameters of a particular event together. Event-model data have been collected by using a CAMAC Fast Crate controller. The host computer system, in hard environment, is equipped with certain peripheral device. It includes the following: 1. at least two M990 GCR, 6250B/inch, magnetic tape driver operating at 75 inches per second or faster; 2. a Tektronix 4014 storage scope; 3. a laser printer, LND3-AE or copier which is capable of making hard-copies of Tektronix 4014 screen; 4. a control console device and a line printer; 5. x-press color graphics terminal; 6. DEC network. When the system is in real-time acquisition, it is able, on-line, to handle and analyse data stream, to monitor and control experiment and to display dynamically spectra on the Tektronix 4014

  2. Integration of the trigger and data acquisition systems in ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Abolins, M [Michigan State University, Department of Physics and Astronomy, East Lansing, Michigan (United States); Adragna, P [Department of Physics, Queen Mary and Westfield College, University of London, London (United Kingdom); Aleksandrov, E; Aleksandrov, I [Joint Institute for Nuclear Research, Dubna (Russian Federation); Amorim, A [Laboratorio de Instrumentacao e Fisica Experimental, Lisboa (Portugal); Anderson, K [University of Chicago, Enrico Fermi Institute, Chicago, Illinois (United States); Anduaga, X [National University of La Plata, La Plata (United States); Aracena, I; Bartoldus, R [Stanford Linear Accelerator Center (SLAC), Stanford (United States); Asquith, L [Department of Physics and Astronomy, University College London, London (United Kingdom); Avolio, G; Backlund, S [European Laboratory for Particle Physics (CERN), Geneva (Switzerland); Badescu, E [National Institute for Physics and Nuclear Engineering, Institute of Atomic Physics, Bucharest (Romania); Baines, J [Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Beck, H P [Laboratory for High Energy Physics, University of Bern, Bern (Switzerland); Bee, C [Centre de Physique des Particules de Marseille, IN2P3-CNRS, Marseille (France); Bell, P [Department of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Bell, W H [Department of Physics and Astronomy, University of Glasgow, Glasgow (United Kingdom); Barria, P; Batreanu, S [and others

    2008-07-01

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system.

  3. Integration of the trigger and data acquisition systems in ATLAS

    International Nuclear Information System (INIS)

    Abolins, M; Adragna, P; Aleksandrov, E; Aleksandrov, I; Amorim, A; Anderson, K; Anduaga, X; Aracena, I; Bartoldus, R; Asquith, L; Avolio, G; Backlund, S; Badescu, E; Baines, J; Beck, H P; Bee, C; Bell, P; Bell, W H; Barria, P; Batreanu, S

    2008-01-01

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system

  4. Integration of the Trigger and Data Acquisition Systems in ATLAS

    International Nuclear Information System (INIS)

    Abolins, M.; Adragna, P.; Aleksandrov, E.; Aleksandrov, I.; Amorim, A.; Anderson, K.; Anduaga, X.; Aracena, I.; Asquith, L.; Avolio, G.; Backlund, S.; Badescu, E.; Baines, J.; Barria, P.; Bartoldus, R.; Batreanu, S.; Beck, H.P.; Bee, C.; Bell, P.; Bell, W.H.; Bellomo, M.

    2011-01-01

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system.

  5. A Web-Remote/Robotic/Scheduled Astronomical Data Acquisition System

    Science.gov (United States)

    Denny, Robert

    2011-03-01

    Traditionally, remote/robotic observatory operating systems have been custom made for each observatory. While data reduction pipelines need to be tailored for each investigation, the data acquisition process (especially for stare-mode optical images) is often quite similar across investigations. Since 1999, DC-3 Dreams has focused on providing and supporting a remote/robotic observatory operating system which can be adapted to a wide variety of physical hardware and optics while achieving the highest practical observing efficiency and safe/secure web browser user controls. ACP Expert consists of three main subsystems: (1) a robotic list-driven data acquisition engine which controls all aspects of the observatory, (2) a constraint-driven dispatch scheduler with a long-term database of requests, and (3) a built-in "zero admin" web server and dynamic web pages which provide a remote capability for immediate execution and monitoring as well as entry and monitoring of dispatch-scheduled observing requests. No remote desktop login is necessary for observing, thus keeping the system safe and consistent. All routine operation is via the web browser. A wide variety of telescope mounts, CCD imagers, guiding sensors, filter selectors, focusers, instrument-package rotators, weather sensors, and dome control systems are supported via the ASCOM standardized device driver architecture. The system is most commonly employed on commercial 1-meter and smaller observatories used by universities and advanced amateurs for both science and art. One current project, the AAVSO Photometric All-Sky Survey (APASS), uses ACP Expert to acquire large volumes of data in dispatch-scheduled mode. In its first 18 months of operation (North then South), 40,307 sky images were acquired in 117 photometric nights, resulting in 12,107,135 stars detected two or more times. These stars had measures in 5 filters. The northern station covered 754 fields (6446 square degrees) at least twice, the southern

  6. The trigger and data acquisition system of the SAPHIR detector

    International Nuclear Information System (INIS)

    Honscheid, K.

    1988-10-01

    At present SAPHIR, a new experimental facility for medium energy physics is under construction at the Bonn electron accelerator ELSA (energy ≤ 3.5 GeV, duty cycle ≅ 100%). SAPHIR combines a large solid angle coverage with a tagging system and is therefore suited to investigate reactions with multi-particle final states. Structure and function of the multi-stage trigger system, which is used to select such processes, are described in this paper. With this system the trigger decision can be based on the number of charged particles as well as on the number of neutral particle detected. Several VMEbus modules have been developed, using memory look-up tables to make fast trigger decisions possible. In order to determine the number of neutral particles from the cluster distribution in the electromagnetic calorimeter some ideas of cellular had to be added. The system has a modular structure, so it can easily be extended. In the second part of this thesis the SAPHIR data acquisition system is discussed. It consists of a multiprocessor system with the VIP microcomputer as central element. The VIP is a VMEbus modul optimized for a multiprocessor environment. Its description as well as that of the other VMEbus boards developed for the SAPHIR online system can be found in this paper. As a basis for software development the operating system SOS is supplied. With SOS it is possible to write programs independent of the actual hardware configuration and so the complicated multiprocessor environment is hidden. To the user the system looks like a simple multi-tasking system. SOS is not restricted to the VIPs but can also be installed on computers of the VAX family, so that efficient mixed configurations are possible. The SAPHIR online system, based on the VIP microcomputer and the SOS operating system, is presented in the last part of this paper. This includes the read-out system, the monitoring of the different components etc. (orig./HSI) [de

  7. The TJ-II data acquisition system: an overview

    International Nuclear Information System (INIS)

    Vega, J.; Cremy, C.; Sanchez, E.; Portas, A.

    1999-01-01

    The data acquisition system for the TJ-II fusion machine has been developed to coordinate actions among the several experimental systems devoted to data capture and storage: instrumentation mainframes (VXI, VME, CAMAC), control systems of diagnostics and a host-centralized database. Connectivity between these elements is achieved through local area networks, which ensure both good connections and system growth capability. Three hundred VXI based digitizer channels have been developed for TJ-II diagnostics. They are completely software programmable and provide signal analog conditioning. In addition, some of them supply a programmable DSP for real time signal processing. Data will be stored in a central server using a special compression technique that allows compaction rates of over 80%. A specific application software has been developed to provide user interface for digitizer programming, signal visualization and data processing during TJ-II discharges. The software is an event based application that can be remotely launched from any X terminal An authentication mechanism restricts access to authorised users only. (orig.)

  8. A Java-based data acquisition system for nuclear physics

    International Nuclear Information System (INIS)

    Swartz, K.B.; Visser, D.W.; Baris, J.M.

    2001-01-01

    Jam is a Java-based user-friendly data acquisition and analysis system developed for CAMAC-based nuclear physics experiments. The system is menu-driven and has been designed to minimize the expertise needed to perform the essential tasks necessary to collect and sort data. The front-end hardware is VME based and includes a MVME167 running VxWorks, which is networked to a Sun workstation. The sorting, display, and control routines are all written in Java, and the front-end code is written in C. With a Sparc 5 workstation, events with 10 parameters, 15 histograms, and 10 gate checks the system can collect and sort data up to event rates of 1 kHz. By only sorting a fraction of the events, but storing all events, it can be run at the front-end limit of 10 kHz. Java's promise of platform independence has been found to be realistic, and Jam has been used with no modifications to sort offline on multiple platforms. Jam has a modular design allowing it to be easily modified. For example, Jam has an interface to allow users to write their own fitting routines. This article discusses the system's design and performance, as well as some advantages and disadvantages of using Java

  9. Operational experience with the CMS Data Acquisition System

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The data-acquisition (DAQ) system of the CMS experiment at the LHC performs the read-out and assembly of events accepted by the first level hardware trigger. Assembled events are made available to the high-level trigger (HLT), which selects interesting events for offline storage and analysis. The system is designed to handle a maximum input rate of 100 kHz and an aggregated throughput of 100 GB/s originating from approximately 500 sources and 10^8 electronic channels. An overview of the architecture and design of the hardware and software of the DAQ system is given. We report on the performance and operational experience of the DAQ and its Run Control System in the first two years of collider run of the LHC, both in proton-proton and Pb-Pb collisions. We present an analysis of the current performance, its limitations, and the most common failure modes and discuss the ongoing evolution of the HLT capability needed to match the luminosity ramp-up of the LHC.

  10. THE ATLAS DATA ACQUISITION SYSTEM IN LHC RUN 2

    CERN Document Server

    Pozo Astigarraga, Mikel Eukeni; The ATLAS collaboration

    2017-01-01

    The LHC has been providing proton-proton collisions with record intensity and energy since the start of Run 2 in 2015. In the ATLAS experiment the Data Acquisition is responsible for the transport and storage of the more complex event data at higher rates that the new collision environment implies. Data from events selected by the first level hardware trigger are subject to further filtration from software running on a commodity server farm. During this time the data are transferred from detector electronics across 1900 optical links to custom buffer hardware hosted across 100 commodity server PCs, and then across the system for processing by high bandwidth network at an average throughput of 30 GB/s. Accepted events are transported to a data logging system for final packaging and transfer to permanent storage, with an average output rate of 1.5 GB/s. The whole system is actively monitored to maximise efficiency and minimise downtime. Due to the scale of the system and the challenging collision environment th...

  11. Control and data acquisition system for rotary compressor

    Directory of Open Access Journals (Sweden)

    Buczaj Marcin

    2017-01-01

    Full Text Available The rotary compressor (crimping machine is a machine designed for making hollow forgings. The rotary compressor is a prototype device designed and built at the Technical University of Lublin. The compressor is dedicated to perform laboratory tests related to the hollow forgings of various shapes using different materials. Since the rotary compressor is an experimental device, there is no control and acquisition data system available. The article presents the concept and the capabilities of the computer control and data acquisition system supporting rotary compressing process. The main task of software system is acquisition of force and kinetic parameters related to the analysed process of the rotary forging compression. The software allows the user to declare the course of the forming forgings. This system allows current recording and analysis of four physical values: feed rate (speed of working head movement, hydraulic oil pressure at inlet and outlet of hydraulic cylinder and the torque of engine. Application functions can be divided into three groups: the configuration of the pressing process, the acquisition and analysis of data from the pressing process and the recording and presentation of stored results. The article contains a detailed description about hardware and software implementation of mentioned functions.

  12. Buffer provisioning for large-scale data-acquisition systems

    CERN Document Server

    AUTHOR|(SzGeCERN)756497; The ATLAS collaboration; Garcia Garcia, Pedro Javier; Froening, Holger; Vandelli, Wainer

    2018-01-01

    The data acquisition system of the ATLAS experiment, a major experiment of the Large Hadron Collider (LHC) at CERN, will go through a major upgrade in the next decade. The upgrade is driven by experimental physics requirements, calling for increased data rates on the order of 6~TB/s. By contrast, the data rate of the existing system is 160~GB/s. Among the changes in the upgraded system will be a very large buffer with a projected size on the order of 70 PB. The buffer role will be decoupling of data production from on-line data processing, storing data for periods of up to 24~hours until it can be analyzed by the event processing system. The larger buffer will allow a new data recording strategy, providing additional margins to handle variable data rates. At the same time it will provide sensible trade-offs between buffering space and on-line processing capabilities. This compromise between two resources will be possible since the data production cycle includes time periods where the experiment will not produ...

  13. The H.E.S.S. data acquisition system

    CERN Document Server

    Balzer, A; Gajdus, M; Göring, D; Lopatin, A; Murach, T; de Naurois, M; Schlenker, S; Schwanke, U; Stegmann, C; Wagner, P

    2014-01-01

    The High Energy Stereoscopic System (H.E.S.S.) is an array of five Imaging Atmospheric Cherenkov Telescopes located in the Khomas Highland in Namibia. It measures cosmic gamma-rays with very high energies (> 100 GeV) using the Earth's atmosphere as a calorimeter. The H.E.S.S. experiment has entered Phase II in September 2012 with the inauguration of a fifth telescope that is larger and more complex than the other four. The very large mirror area of 600 m(2) in comparison to the 100 m(2) of the smaller telescopes results in a lower energy threshold as well as an increased overall sensitivity of the system. Moreover, the huge effective area, due to the large mirror size, is crucial in the detection of short time scale low energy transient events. This paper will give a brief overview of the design principles of the current H.E.S.S. data acquisition and array control system. Particular emphasis is given to the new Target of Opportunity alert system that has recently been introduced to the array and allows the in...

  14. Near Theoretical Gigabit Link Efficiency for Distributed Data Acquisition Systems.

    Science.gov (United States)

    Abu-Nimeh, Faisal T; Choong, Woon-Seng

    2017-03-01

    Link efficiency, data integrity, and continuity for high-throughput and real-time systems is crucial. Most of these applications require specialized hardware and operating systems as well as extensive tuning in order to achieve high efficiency. Here, we present an implementation of gigabit Ethernet data streaming which can achieve 99.26% link efficiency while maintaining no packet losses. The design and implementation are built on OpenPET, an opensource data acquisition platform for nuclear medical imaging, where (a) a crate hosting multiple OpenPET detector boards uses a User Datagram Protocol over Internet Protocol (UDP/IP) Ethernet soft-core, that is capable of understanding PAUSE frames, to stream data out to a computer workstation; (b) the receiving computer uses Netmap to allow the processing software (i.e., user space), which is written in Python, to directly receive and manage the network card's ring buffers, bypassing the operating system kernel's networking stack; and (c) a multi-threaded application using synchronized queues is implemented in the processing software (Python) to free up the ring buffers as quickly as possible while preserving data integrity and flow continuity.

  15. A triggerless digital data acquisition system for nuclear decay experiments

    Energy Technology Data Exchange (ETDEWEB)

    Agramunt, J.; Tain, J. L.; Albiol, F.; Algora, A.; Estevez, E.; Giubrone, G.; Jordan, M. D.; Molina, F.; Rubio, B.; Valencia, E. [Instituto de Fisica Corpuscular, Centro Mixto C.S.I.C. - Univ. Valencia, Apdo. Correos 22085, 46071 Valencia (Spain)

    2013-06-10

    In nuclear decay experiments an important goal of the Data Acquisition (DAQ) system is to allow the reconstruction of time correlations between signals registered in different detectors. Classically DAQ systems are based in a trigger that starts the event acquisition, and all data related with the event of that trigger are collected as one compact structure. New technologies and electronics developments offer new possibilities to nuclear experiments with the use of sampling ADC-s. This type of ADC-s is able to provide the pulse shape, height and a time stamp of the signal. This new feature (time stamp) allows new systems to run without an event trigger. Later, the event can be reconstructed using the time stamp information. In this work we present a new DAQ developed for {beta}-delayed neutron emission experiments. Due to the long moderation time of neutrons, we opted for a self-trigger DAQ based on commercial digitizers. With this DAQ a negligible acquisition dead time was achieved while keeping a maximum of event information and flexibility in time correlations.

  16. Versatile data acquisition system and the ISOL facility TRISTAN

    International Nuclear Information System (INIS)

    Gill, R.L.; Stelts, M.L.; Chrien, R.E.; Manzella, V.; Liou, H.I.; Shostak, S.

    1980-01-01

    The on-line mass separator, TRISTAN, is located at Brookhaven's High Flux Beam Reactor. A Nielsen-type ion source, which can contain up to 8g. of 235 U in an external beam with a flux of approx. 2 x 10 9 n/cm 2 /sec is used to generate short-lived fission products. A Users Group has been formed to coordinate research between University groups and BNL. Developments planned for TRISTAN include FEBIAD, surface ionization and negative-surface ionization-type ion sources, and a He-jet system as well as construction of new experimental facilities. An off-line separator, ISTU, is available for the development program. A versatile, modular data acquisition system to service experiments on TRISTAN and other nuclear research facilities at the HFBR using Camac interfacing is described. Standard, commercially-available electronic instruments and computer programs, such as FORTRAN and system routines, are used throughout. Simple interfaces have been built to adapt non-Camac equipment to Camac input registers

  17. The STADUS ultrasonic data acquisition and processing system

    International Nuclear Information System (INIS)

    Frappier, J.C.; Birac, A.M.; Saglio, R.

    1983-01-01

    The use of the PRODUS software for real-time system management results in definitely improved date acquisition, although signal arrival is, of course, a random process. As regards data processing and display; the STADUS-PRODUS combination provides the operator with a high degree of flexibility in changing the parameters from which the three standard A-SCAN, B-SCAN, and C-SCAN displays are generated. STADUS effectivity has been demonstrated in the field through the many reactor vessel inspections performed to date. The system has been a key element in the success of underclad cracking detection and evaluation methods. The STADUS equipment, designed and built by CEA, has the advantage of being capable of acquiring a large number of ultrasonic date simultaneously generated by several transducers (up to sixteen), and to immediately process the date for creating pictures of the zone under examination, as required by the operator. Through these improvements in ultrasonic data acquisition and interpretation, the STADUS system helps enhance the quality of automatic ultrasonic examinations

  18. The ATLAS Data Acquisition System in LHC Run 2

    CERN Document Server

    Pozo Astigarraga, Mikel Eukeni; The ATLAS collaboration

    2017-01-01

    The LHC has been providing proton-proton collisions with record intensity and energy since the start of Run 2 in 2015. In the ATLAS experiment the Data Acquisition is responsible for the transport and storage of the more complex event data at higher rates that the new collision environment implies. Data from events selected by the first level hardware trigger are subject to further filtration from software running on a commodity load balanced processing farm of some 2000 servers. During this time the data transferred from detector electronics across 1900 optical links to custom buffer hardware hosted across 100 commodity server PCs, and transferred across the system for processing by high bandwidth network at an average throughput of 30 GB/s. Accepted events are then transported to a data logging system for final packaging and transfer to permanent storage, with a final average output bandwidth of 1.5 GB/s. The whole system is actively monitored to maximise efficiency and minimise downtime. Due to the scale o...

  19. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  20. The Data Acquisition System for a Kinetic Inductance Detector

    International Nuclear Information System (INIS)

    Branchini, P; Budano, A; Capasso, L; Marchetti, D

    2015-01-01

    The Data Acquisition System (DAQ) and the Front-End electronics for an array of Kinetic Inductance Detectors (KIDs) are described. KIDs are superconductive detectors, in which electrons are organized in Cooper pairs. Any incident radiation could break a pair generating a couple of quasi-particles that increase the inductance of the detector. The DAQ system we developed is a hardware/software co-design, based on state machines and on a microprocessor embedded into an FPGA. A commercial DAC/ADC board is used to interface the FPGA to the array of KIDs. The DAQ system generates a Stimulus signal suitable for an array of up to 128 KIDs. Such signal is up-mixed with a 3 GHz carrier wave and it then excites the KIDs array. The read-out signal from the detector is down-mixed with respect to the 3 GHz sine wave and recovered Stimulus is read back by the ADC device. The microprocessor stores read out data via a PCI express bus (PCIe) into an external disk. It also computes the Fast Fourier Transform of the acquired read out signal: this allows extrapolating which KID interacted and the energy of the impinging radiation. Simulations and tests have been performed successfully and experimental results are presented. (paper)

  1. The LHCb front-end electronics and data acquisition system

    CERN Document Server

    Jost, B

    2000-01-01

    The LHCb experiment is the most recently approved of the four experiments under construction at CERN's LHC accelerator. It is a special purpose experiment designed to precisely measure the CP violation parameters in the B-B system and to study rare B-decays. Triggering poses special problems since the interesting events containing B-mesons are immersed in a large background of inelastic p-p reactions. We therefore decided to implement a four-level triggering scheme. The LHCb data acquisition (DAQ) system will have to cope with an average trigger rate of 40 kHz, after two levels of hardware triggers, and an average event size of 100 kB. Thus, an event-building network which can sustain an average bandwidth of 4 GB /s is required. A powerful software trigger farm will have to be installed to reduce the rate from 40 kHz to 100 Hz of events written for permanent storage. In this paper we will outline the general architectures of the front-end electronics and of the trigger and DAQ system and the readout protocols...

  2. A versatile data acquisition system and the ISOL facility TRISTAN

    International Nuclear Information System (INIS)

    Gill, R.L.; Stelts, M.L.; Chrien, R.E.; Manzella, V.; Liou, H.; Shostak, S.

    1981-01-01

    We have constructed a versatile, modular data acquisition system to service experiments on TRISTAN and other nuclear research facilities at the HFBR using CAMAC interfacing. Standard, commercially-available electronic instruments and computer programs, such as FORTRAN and system routines, are used throughout. Simple interfaces have been built to adapt non-CAMAC equipment to CAMAC input registers. Up to eight different experiments can be multiplexed on the branch highway by a fast microprogrammed branch driver with a 4096 word memory. The branch driver delivers pre-processed data to a bus which links devices such as a central processor, 1 megaword core memory, tape drives, discs, display processor and terminal. The following features are offered: two 8192 channel pulse height analyzers, a 3-parameter coincidence unit, 4 multiscalers, a timed sequence of delayed γ-ray spectra (33 spectra of 4096 channels each), a 2-parameter (pulse height versus time-of-flight) analyzer, 16 scalers and 24 experimental interlocks. Up to 100 different spectra are available to users for display during an experiment. (orig./RW)

  3. 40 Gbps data acquisition system for NectarCAM

    Science.gov (United States)

    Hoffmann, Dirk; Houles, Julien; NectarCAM Team; CTA Consortium, the

    2017-10-01

    The Cherenkov Telescope Array (CTA) will be the next generation ground-based gamma-ray observatory. It will be made up of approximately 100 telescopes of three different sizes, from 4 to 23 meters in diameter. The previously presented prototype of a high speed data acquisition (DAQ) system for CTA (CHEP 2012, [6]) has become concrete within the NectarCAM project, one of the most challenging camera projects with very demanding needs for bandwidth of data handling. We designed a Linux-PC system able to concentrate and process without packet loss the 40 Gb/s average data rate coming from the 265 Front End Boards (FEB) through Gigabit Ethernet links, and to reduce data to fit the two ten-Gigabit Ethernet downstream links by external trigger decisions as well as custom tailored compression algorithms. Within the given constraints, we implemented de-randomisation of the event fragments received as relatively small UDP packets emitted by the FEB, using off-the-shelf equipment as required by the project and for an operation period of at least 30 years. We tested out-of-the-box interfaces and used original techniques to cope with these requirements, and set up a test bench with hundreds of synchronous Gigabit links in order to validate and tune the acquisition chain including downstream data logging based on zeroMQ and Google ProtocolBuffers [8].

  4. High speed digital interfacing for a neural data acquisition system

    Directory of Open Access Journals (Sweden)

    Bahr Andreas

    2016-09-01

    Full Text Available Diseases like schizophrenia and genetic epilepsy are supposed to be caused by disorders in the early development of the brain. For the further investigation of these relationships a custom designed application specific integrated circuit (ASIC was developed that is optimized for the recording from neonatal mice [Bahr A, Abu-Saleh L, Schroeder D, Krautschneider W. 16 Channel Neural Recording Integrated Circuit with SPI Interface and Error Correction Coding. Proc. 9th BIOSTEC 2016. Biodevices: Rome, Italy, 2016; 1: 263; Bahr A, Abu-Saleh L, Schroeder D, Krautschneider W. Development of a neural recording mixed signal integrated circuit for biomedical signal acquisition. Biomed Eng Biomed Tech Abstracts 2015; 60(S1: 298–299; Bahr A, Abu-Saleh L, Schroeder D, Krautschneider WH. 16 Channel Neural Recording Mixed Signal ASIC. CDNLive EMEA 2015 Conference Proceedings, 2015.]. To enable the live display of the neural signals a multichannel neural data acquisition system with live display functionality is presented. It implements a high speed data transmission from the ASIC to a computer with a live display functionality. The system has been successfully implemented and was used in a neural recording of a head-fixed mouse.

  5. Proceedings of the second data acquisition system workshop

    International Nuclear Information System (INIS)

    Ohska, T.K.

    1988-02-01

    The second data acquisition system workshop was held on July 18 and 19, 1986 at the National Laboratory for High Energy Physics (KEK). The organizers had one thing in mind when this workshop was planned. It was wanted to make a record of mistakes in designing and building the electronic system. The time when this workshop was held was just before the completion of the TRISTAN detectors when everyone was very busy. Brilliant achievements have been published every year in the world, but the hard earned experience on what should not be done does not appear on publication. To record it while it is still hot was the basic motivation of this workshop. More than 100 people attended the workshop, and some speakers did excellently what the organizers hoped to do, but some talked on their great achievements only. The organizers are very thankful to everybody who helped before, during and after the workshop. If possible, it should be asked all speakers to hand in their write-ups on the day of the workshop. Actually, the last write-up was received almost one year late, and the publication of this report delayed. In this book, those write-ups are collected. (Kako, I.)

  6. Development and Integration of a Data Acquisition System for SST-1 Phase-1 Plasma Diagnostics

    International Nuclear Information System (INIS)

    Srivastava, Amit K; Sharma, Manika; Mansuri, Imran; Sharma, Atish; Raval, Tushar; Pradhan, Subrata

    2012-01-01

    Long pulse (of the order of 1000 s or more) SST-1 tokamak experiments demand a data acquisition system that is capable of acquiring data from various diagnostics channels without losing useful data (and hence physics information) while avoiding unnecessary generation of a large volume data. SST-1 Phase-1 tokamak operation has been envisaged with data acquisition of several essential diagnostics channels. These channels demand data acquisition at a sampling rate ranging from 1 kilo samples per second (KSPS) to 1 mega samples per second (MSPS). Considering the technical characteristics and requirements of the diagnostics, a data acquisition system based on PXI and CAMAC has been developed for SST-1 plasma diagnostics. Both these data acquisition systems are scalable. Present data acquisition needs involving slow plasma diagnostics are catered by the PXI based data acquisition system. On the other hand, CAMAC data acquisition hardware meets all requirements of the SST-1 Phase-1 fast plasma diagnostics channels. A graphical user interface for both data acquisition systems (PXI and CAMAC) has been developed using LabVIEW application development software. The collected data on the local hard disk are directly streaming to the central server through a dedicated network for post-shot data analysis. This paper describes the development and integration of the data acquisition system for SST-1 Phase-1 plasma diagnostics. The integrated testing of the developed data acquisition system has been performed using SST-1 central control and diagnostics signal conditioning units. In the absence of plasma shots, the integrated testing of the data acquisition system for the initial diagnostics of SST-1 Phase-1 operation has been performed with simulated physical signals. The primary engineering objective of this integrated testing is to validate the performance of the developed data acquisition system under simulated conditions close to that of actual tokamak operation. The data

  7. Data acquisition system for the Pelletron electron accelerator

    International Nuclear Information System (INIS)

    Flores E, O.

    1997-01-01

    In this work, a system is developed that allows to know and view of immediate manner the conditions occurred during the operation of the Pelletron. This is carried out by means of the design of a data acquisition system which displays in graphic form, in the screen of a computer, the operation conditions like pressure of the tank, current of the electron beam, voltage in the inductors of the elctrostatic generator, level of produced radiation, etc., all of this parameters determine the behavior of the accelerator. The hardware of the system includes the design and construction of conditioning and transmission circuits used to send the information to an interface board that allows th communication between the analog world and the computer. In this case, the utilized board is the AT-MIO-16L-25, that is a high-performance multifunction analog, digital and timing input/output (I/O) board for the IBM PC/AT and compatibles. The software implicates the design of the necessary programs to manipulate the interface board, for the processing and presentation of information in the screen of the computer and also for the storage of the acquired data in a permanent medium. In this case, a relatively new tool, known like Virtual instrumentation is utilized. Concretely, the LabVIEW programming software package is used (Laboratory Virtual Instrument Engineering Workbench), which is designed for applications in instrumentation and control. This programming package gives the necessary elements for the analysis and processing of the acquired data. The system is developed in base to the requirements done for the users and designers of the Pelletron. (Author)

  8. Data acquisition and management system for a nuclear processes simulator

    International Nuclear Information System (INIS)

    Gonzalez M, J.A.; Santiago C, J.

    2003-01-01

    In the development of this work (Data acquisition and management system for a simulator of nuclear processes (SAMAD)), is important to mention the main modules that involve the operation of the same one. At the beginning it was necessary to contemplate the possible programming languages, as well as the compatibility and handling easiness among them. The used languages to be able to land the contemplated ideas are: C ++ , PHP, HTML, as well as the My SQL database manager. After this it was designed the database (DB), which contains the tables of each one of the components, this according to the enter file type of the RELAP5 code that will be use for each simulation, as well as, tables that will allow us to relate and to maintain the control of the information supplied to the DB. Once created the database is interacting with it through an application program based on PHP (Preprocessor). The application basically consists, in extracting the data from each one of the components to work in that moment, that is to say, to obtain the data of the enter file, as well as, to depurate the data, excluding comments. The preprocessor gives bigger easiness to place the data in the DB. Also, it was developed an graphic interface that allows to register variables to the DB, depending from the unfolding to visualize. Another application that has been implemented is the Data Collector that has as function, to obtain in a direct way the data of the display variables of the RELAP5 code, with the purpose of storing them in the DB, this will be carry out in real time and it was updated in a very small time period. (Author)

  9. The application of USB2.0 in a data acquisition system

    International Nuclear Information System (INIS)

    Xiang Guilai; Zheng Jian

    2007-01-01

    To design a data acquisition system based on USB, there are two key points to be worked out. First, right comprehension and application of the concepts such as transfer, transaction, packet and handshake are required. Second, the timing relationship between data acquisition and data transfer must be well handled. Based on the characteristics of a real system, this article gives a detailed description of design process of data acquisition systems. (authors)

  10. Data Acquisition (DAQ) system dedicated for remote sensing applications on Unmanned Aerial Vehicles (UAV)

    Science.gov (United States)

    Keleshis, C.; Ioannou, S.; Vrekoussis, M.; Levin, Z.; Lange, M. A.

    2014-08-01

    Continuous advances in unmanned aerial vehicles (UAV) and the increased complexity of their applications raise the demand for improved data acquisition systems (DAQ). These improvements may comprise low power consumption, low volume and weight, robustness, modularity and capability to interface with various sensors and peripherals while maintaining the high sampling rates and processing speeds. Such a system has been designed and developed and is currently integrated on the Autonomous Flying Platforms for Atmospheric and Earth Surface Observations (APAESO/NEA-YΠOΔOMH/NEKΠ/0308/09) however, it can be easily adapted to any UAV or any other mobile vehicle. The system consists of a single-board computer with a dual-core processor, rugged surface-mount memory and storage device, analog and digital input-output ports and many other peripherals that enhance its connectivity with various sensors, imagers and on-board devices. The system is powered by a high efficiency power supply board. Additional boards such as frame-grabbers, differential global positioning system (DGPS) satellite receivers, general packet radio service (3G-4G-GPRS) modems for communication redundancy have been interfaced to the core system and are used whenever there is a mission need. The onboard DAQ system can be preprogrammed for automatic data acquisition or it can be remotely operated during the flight from the ground control station (GCS) using a graphical user interface (GUI) which has been developed and will also be presented in this paper. The unique design of the GUI and the DAQ system enables the synchronized acquisition of a variety of scientific and UAV flight data in a single core location. The new DAQ system and the GUI have been successfully utilized in several scientific UAV missions. In conclusion, the novel DAQ system provides the UAV and the remote-sensing community with a new tool capable of reliably acquiring, processing, storing and transmitting data from any sensor integrated

  11. Hardware overview of the EUROGAM data acquisition system

    International Nuclear Information System (INIS)

    Alexander, J.; Owen, E.C.G.; Lazaurs, I.; McPherson, G.M.; Beck, F.A.; Ring, C.; Ender, C.; Pouxe, J.; Richard, A.

    1992-01-01

    This paper reports on EUROGAM, an Anglo/French ray detector which will alternate between the tandem Van der Graaf accelerator at Daresbury and the Vivitron at Strasbourg. Because of the very sensitive nature of the electronics for Germanium gamma ray detection, VXIbus (VMEbus extensions for instrumentation) was chosen as the basis for data acquisition. A major program of development, shared between the British and French participants, is now in its final stages for operation in early 1992

  12. DAPHNE: a parallel multiprocessor data acquisition system for nuclear physics

    International Nuclear Information System (INIS)

    Welch, L.C.

    1984-01-01

    This paper describes a project to meet these data acquisition needs for a new accelerator, ATLAS, being built at Argonne National Laboratory. ATLAS is a heavy-ion linear superconducting accelerator providing beam energies up to 25 MeV/A with a relative spread in beam energy as good as .0001 and a time spread of less than 100 psec. Details about the hardware front end, command language, data structure, and the flow of event treatment are covered

  13. System design description for mini-dacs data acquisition and control system

    International Nuclear Information System (INIS)

    Vargo, F.G. Jr.; Trujillo, L.T.; Smith, S.O.

    1994-01-01

    This document describes the hardware computer system, for the mini data acquisition and control system (DACS) that was fabricated by Los Alamos National Laboratory (LANL), to support the testing of the spare mixer pump for SY-101

  14. Determination of characteristics of feromagnetic material using modern data acquisition system

    Directory of Open Access Journals (Sweden)

    Koprivica Branko

    2009-01-01

    Full Text Available This paper describes the use of modern measuring and data acquisition system for determining characteristics of feromagnetic material. For this purpose data acquisition card NI USB-6009, PC with data acquisition software and fluxmeter Electrical Steel Measuring System MPG 100 D were used. Based on the results obtained by measurements the modeling of hysteresis loop is performed by using appropriate mathematical model.

  15. The Wireless Data Acquisition System for the Vibration Table

    Science.gov (United States)

    Teng, Y. T.; Hu, X.

    2014-12-01

    The vibration table is a large-scaled tool used for inspecting the performance of seismometers. The output from a seismometer on the table can be directly monitored when the vibration table moves in certain pattern. Compared with other inspection methods, inspecting seismometers' performance indicators (frequency response, degree of linearity, sensitivity, lateral inhibition and dynamic range etc). using vibration tables is more intuitive. Therefore, the vibration tables are an essential testing part in developing new seismometers and seismometer quality control. Whereas, in practice, a cable is needed to connect the seismometer to the ground equipments for its signal outputs and power supply, that means adding a time-varying nonlinear spring between the vibration table and ground. The cable adds nonlinear feature to the table, distorts the table-board movement and bring extra errors to the inspecting work and affected the testing accuracy and precision. In face of this problem, we developed a wireless acquiring system for the vibration table. The system is consisted of a three-channel analog-to-digital conversion, an acquisition control part, local data storage, network interface, wireless router and power management, etc. The analog-to-digital conversion part uses a 24-digit high-precision converter, which has a programmable amplifier at the front end of its artificial circuit, with the function of matching outputs with different amplifier from the vibration table. The acquisition control part uses a 32 bit ARM processor, with low-power dissipation, minute extension and high performance. The application software platform is written in Linux to make the system convenient for multitasking work. Large volume local digital storage is achieved by a 32G SD card, which is used for saving real time acquired data. Data transmission is achieved by network interface and wireless router, which can simplify the application software by the supported TCP/IP protocol. Besides

  16. Computer system design description for the spare pump mini-dacs data acquisition and control system

    International Nuclear Information System (INIS)

    Vargo, G.F. Jr.

    1994-01-01

    The attached document outlines the computer software design for the mini data acquisition and control system (DACS), that supports the testing of the spare pump for Tank 241-SY-101, at the maintenance and storage facility (MASF)

  17. The IMB nucleon decay detector data acquisition and triggering system

    CERN Document Server

    LoSecco, J M; Foster, G W; Shumard, E; Van der Velde, J C

    1981-01-01

    The data acquisition hardware and software for a large deep underground nucleon stability detector is described. Such hardware must process the information from an array of greater than 2000 photomultiplier tubes in real time, in the presence of a cosmic-ray background of about three events per second. A hierarchical scheme of processors and memory is used to perform real time pattern recognition and event identification with negligible impact on dead time. Fast, but crude, algorithms have been developed to reduce the offline analysis work load without endangering any of the alternative physics objectives, such as neutrino oscillations or neutrino burst detection. (8 refs).

  18. The IMB nucleon decay detector data acquisition and triggering system

    International Nuclear Information System (INIS)

    LoSecco, J.; Shumard, E.; Van der Velde, J.; Cortez, B.; Foster, G.W.

    1981-01-01

    The data acquisition hardware and software for large deep underground nucleon stability detector will be described. Such hardware must process the information from an array of greater than 2000 photomultiplier tubes in real time, in the presence of a cosmic ray background of about three events per second. A hierachical scheme of processors and memory is used to perform real time pattern recognition and events identification with negligible impact on dead time. Fast, but crude, algorithms have been developed to reduce the offline analysis work load without endangering any of the alternate physics objectives, such as neutrino oscillations or neutrino burst detection. (orig.)

  19. TELL1 data acquisition system for LHCb detectors

    International Nuclear Information System (INIS)

    Gong Guanghua; Xue Tao; Gong Hui; Shao Beibei

    2004-01-01

    A FPGA based data acquisition readout board has been developed for the LHCb detectors. With optical or analogue daughter cards, it can readout data from several different off-detector electronics. The data synchronization, buffering, pre-processing, zero-suppression and many interfaces to memory chips and communication buses are all implemented by the FPGA in VHDL code. The board sends data out via a 4 channel Gigabit Ethernet adapter. The TELL1 can accepts 24 optical links running at 1.6 GHz and provides for the analogue option 64 10-bit ADC channels sampling at 40 MHz. (authors)

  20. A CAMAC-based data acquisition system with a Macintosh interface

    International Nuclear Information System (INIS)

    McKisson, J.E.; Ely, D.W.; Weisenberger, A.G.; Piercy, R.B.; Haskins, P.S.

    1990-01-01

    This paper describes a commercially available Macintosh-based data acquisition system and its application to a specific measurement. Based on Computer Aided Measurement and Control (CAMAC) and Nuclear Instrumentation Module (NIM) standard modules, the data acquisition system features a hardware and software interface to a Macintosh computer. This system has been used both for laboratory and remote site measurements, and has been found to perform well as both a highly interactive laboratory system and as a very automatable system for long term data acquisition. Ease in configuration allows for flexibility in fast response applications where a data acquisition system is needed in short time. The system software also supports much of the data analysis and presentation of results with a versatile set of histogram display and manipulation tools. In a recent application, the system controlled data acquisition for two germanium detectors used as part of the whole- spacecraft induced activation measurements of the Long Duration Exposure Facility (LDEF) satellite

  1. Expansion of the data acquisition system for the 20 MV tandem accelerator

    International Nuclear Information System (INIS)

    Tomita, Yoshiaki

    1981-02-01

    This report describes an expansion of the program of the data acquisition system for the 20 MV tandem accelerator. By the present expansion it became possible to change the accuisition mode or to use non-standard CAMAC modules with partial modification of the program according to well defined prescriptions. The modification can be made by writing microprograms for the MBD or appending subroutines for the reduced spectra in the LIST mode data acquisition. The new program can handle up to 32 ADC's in the standard LIST mode data acquisition. The present expansion aimed to increase the flexibility in data acquisition. It can also be applied to control experimental devices. (author)

  2. Neutron flux density data acquisition system based on LabVIEW

    International Nuclear Information System (INIS)

    Zhao Yanhui; Zhao Xiuliang; Li Zonglun; Liang Fengyan; Liu Liyan

    2011-01-01

    In the LabVIEW software, combined with PCI-6251 data acquisition card, VI of neutron flux density data acquisition is realized by DAQmx data acquisition functions. VI is composed of front panel and block diagram. The data collected can be displayed in the forms of the data curve and the data control, and saved in the form of files. Test results show that the frequency of output signal in NI ELVIS can be accurately measured by the system, realizing neutron flux density data acquisition based on LabVIEW. (authors)

  3. The implementation of a data acquisition and service system based on HDF5

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y., E-mail: cheny@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Wang, F.; Li, S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Xiao, B.J. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); School of nuclear science and technology, University of Science and Technology of China, Hefei, Anhui (China); Yang, F. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Department of Computer Science, Anhui Medical University, Hefei, Anhui (China)

    2016-11-15

    Highlights: • A new data acquisition and service system has been designed and implemented for a new reversed field pinch (RFP) magnetic confinement device. • The new data acquisition and service system is based on HDF5. • It is an entire system including acquisition, storage and data retrieval. • The system is easy to extend and maintain for its modularization design. - Abstract: A data acquisition and service system based on HDF5 has been designed. It includes four components: data acquisition console, data acquisition subsystem, data archive system and data service. The data acquisition console manages all DAQ information and controls the acquisition process. The data acquisition subsystem supports continuous data acquisition with different sampling rates which can be divided into low, medium and high level. All experimental data will be remotely transferred to the data archive system. It adopts HDF5 as its low-level data storage format. The hierarchical data structure of HDF5 is useful for efficiently managing the experimental data and allows users to define special data types and compression filter which can be useful to deal with special signals. Several data service tools have also been developed so that users can get data service via Client/Server or Brower/Server. The system will be demonstrated on Keda Torus eXperiment (KTX) device, which is a new Reversed Field Pinch (RFP) magnetic confinement device. The details are presented in the paper.

  4. The implementation of a data acquisition and service system based on HDF5

    International Nuclear Information System (INIS)

    Chen, Y.; Wang, F.; Li, S.; Xiao, B.J.; Yang, F.

    2016-01-01

    Highlights: • A new data acquisition and service system has been designed and implemented for a new reversed field pinch (RFP) magnetic confinement device. • The new data acquisition and service system is based on HDF5. • It is an entire system including acquisition, storage and data retrieval. • The system is easy to extend and maintain for its modularization design. - Abstract: A data acquisition and service system based on HDF5 has been designed. It includes four components: data acquisition console, data acquisition subsystem, data archive system and data service. The data acquisition console manages all DAQ information and controls the acquisition process. The data acquisition subsystem supports continuous data acquisition with different sampling rates which can be divided into low, medium and high level. All experimental data will be remotely transferred to the data archive system. It adopts HDF5 as its low-level data storage format. The hierarchical data structure of HDF5 is useful for efficiently managing the experimental data and allows users to define special data types and compression filter which can be useful to deal with special signals. Several data service tools have also been developed so that users can get data service via Client/Server or Brower/Server. The system will be demonstrated on Keda Torus eXperiment (KTX) device, which is a new Reversed Field Pinch (RFP) magnetic confinement device. The details are presented in the paper.

  5. The MicroVAX-based data acquisition system for D0

    International Nuclear Information System (INIS)

    Cutts, D.; Hoftun, J.S.; McLean, J.; Johnson, C.R.; Zeller, R.T.

    1987-01-01

    A large array of Micro VAX computers will be used for high-speed data acquisition and online filtering in the D0 experiment at Fermi National Laboratory. Described is this system, as well as several smaller data acquisition systems now operational, with particular emphasis on the control and communication software. The computers in this array will run under VAXELN

  6. Real time data acquisition and processing system software supported by RDOS

    International Nuclear Information System (INIS)

    Yang Huimin; Chou Gongchun; Hao Shuxiang

    1982-01-01

    The paper describes a system software supported by RDOS operating system for management and supervision a multiuser nuclear spectrum data acquisition and processing system to be made of NOVA/840 computer. The system has manifold functions including four direct address data acquisition channels. One multi-dimension nuclear data acquisition channel, four scalers and four automatic control entrances. Every channel is used competitively by each user. The system's management and all processing functions are performed by system software. The architecture of the system can renew according to users' requirement with support of the system software.This article explains the logical structure of the system software and discusses some technical keys

  7. Wireless, battery-operated data acquisition system for mobile spectrometry applications and (potentially) for the Internet of things

    Science.gov (United States)

    Fitzgerald, Ryan; Karanassios, Vassili

    2017-05-01

    There are many applications requiring chemical analysis in the field and analytical results in (near) real-time. For example, when accidental spills occur. In others, collecting samples in the field followed by analysis in a lab increases costs and introduces time-delays. In such cases, "bring part of the lab to the sample" would be ideal. Toward this ideal (and to further reduce size and weight), we developed a relatively inexpensive, battery-operated, wireless data acquisition hardware system around an Arduino nano micro-controller and a 16-bit ADC (Analog-to- Digital Converter) with a max sampling rate of 860 samples/s. The hardware communicates the acquired data using low-power Bluetooth. Software for data acquisition and data display was written in Python. Potential ways of making the hardware-software approach described here a part of the Internet-of-Things (IoT) are presented.

  8. Laser velocimeter data acquisition, processing, and control system

    International Nuclear Information System (INIS)

    Croll, R.H. Jr.; Peterson, C.W.

    1975-01-01

    The use of a mini-computer for data acquisition, processing, and control of a two-velocity-component dual beam laser velocimeter in a low-speed wind tunnel is described in detail. Digital stepping motors were programmed to map the mean-flow and turbulent fluctuating velocities in the test section boundary layer and free stream. The mini-computer interface controlled the operation of the LV processor and the high-speed selection of the photomultiplier tube whose output was to be processed. A statistical analysis of the large amount of data from the LV processor was performed by the computer while the experiment was in progress. The resulting velocities are in good agreement with hot-wire survey data obtained in the same facility

  9. Electronics engineering tools for modern data acquisition systems

    International Nuclear Information System (INIS)

    Cardoso, Guilherme; Kwan, Simon; Vergara, Sergio; Sheaff, Marleigh

    2003-01-01

    The very large number of channels and high data rates in modern particle physics experiments put very stringent requirements on the acquisition of data. To reduce the cost as well as the number of cables required to transport the data from detector to counting room, it is necessary to use very large scale integrated circuits for pre-processing the data right on the front-end circuit boards. Also, very high speed optoelectronic circuits are needed to transport the data on to the counting room from the front-end circuits. Two techniques relevant to data acquisition are discussed. The first is Field Programmable Gate Arrays (FPGAs), including using the Very High Speed Integrated Circuit Hardware Description Language (VHDL) to program them. The second is the design of a very high speed optoelectronic circuit for data transport

  10. Data acquisition and analysis system for the ion microprobe mass analyzer

    International Nuclear Information System (INIS)

    Darby, D.M.; Cristy, S.S.

    1979-02-01

    A computer was interfaced to an ion microprobe mass analyzer for more rapid data acquisition and analysis. The interface is designed to allow data acquisition, independent of the computer. A large data analysis package was developed and implemented. Performance of the computerized system was evaluated and compared to manual operation

  11. Ultra-Low Power Sensor System for Disaster Event Detection in Metro Tunnel Systems

    Directory of Open Access Journals (Sweden)

    Jonah VINCKE

    2017-05-01

    Full Text Available In this extended paper, the concept for an ultra-low power wireless sensor network (WSN for underground tunnel systems is presented highlighting the chosen sensors. Its objectives are the detection of emergency events either from natural disasters, such as flooding or fire, or from terrorist attacks using explosives. Earlier works have demonstrated that the power consumption for the communication can be reduced such that the data acquisition (i.e. sensor sub-system becomes the most significant energy consumer. By using ultra-low power components for the smoke detector, a hydrostatic pressure sensor for water ingress detection and a passive acoustic emission sensor for explosion detection, all considered threats are covered while the energy consumption can be kept very low in relation to the data acquisition. In addition to 1 the sensor system is integrated into a sensor board. The total average power consumption for operating the sensor sub-system is measured to be 35.9 µW for lower and 7.8 µW for upper nodes.

  12. Development status of data acquisition system for IFMIF/EVEDA accelerator

    International Nuclear Information System (INIS)

    Usami, Hiroki; Takahashi, Hiroki; Komukai, Satoshi

    2015-01-01

    EU and JAEA are advancing development of Linear IFMIF Prototype Accelerator (LIPAc) control system jointly, but JAEA keeps developing central control system (CCS) mainly. Data transfer during an equipment control system of CCS and EU is performed through EPICS. JAEA is using PostgreSQL as 1 of development elements in CCS and is advancing development of the system to record the whole EPICS data of LIPAc (the data acquisition system). On the other hand, a data acquisition is performed using BEAUTY (Best Ever Archive Toolset, yet) in an element test of equipment at Europe. Therefore '1 client refers to collected data by more than one server machine' with 'compatibility securement of data with BEAUTY' in case of development of the data acquisition system of CCS, and, it's necessary to consider 'To do a data acquisition and backup work at the same time.' For the moment, former 2 are in progress. And a demonstration of the data acquisition system is being performed simultaneously with commissioning in injector. The data acquisition system is collecting data of injector other ones, and the data reference by a monitor with CSS (Control System Studio) is also possible. We will report on the current state of the development of the data acquisition system by making reference to a result of the test by injector commissioning. (author)

  13. The on-line data acquisition system for the MHD facility of Frascati

    International Nuclear Information System (INIS)

    Di Bartolomeo, M.; Papalia, B.; Gay, P.; Panaccione, L.

    1975-01-01

    An on-line data acquisition system for the MHD facility of the Laboratorio Conversione Diretta at Frascati is described. After a brief description of the MHD facility and of the measurement requirements, the criteria a,d the configuration of the minicomputer-based data acquisition system chosen are presented. Then the general philosophy and the flow-charts of the software implemented are shown, with particular emphasis to the real-time requirements of the measurement system. At last it is illustrated an off-line program, running on a large computer, that elaborates the output data of the data acquisition system

  14. On Board Data Acquisition System with Intelligent Transducers for Unmanned Aerial Vehicles

    Science.gov (United States)

    Rochala, Zdzisław

    2012-02-01

    This report presents conclusions from research project no. ON50900363 conducted at the Mechatronics Department, Military University of Technology in the years 2007-2010. As the main object of the study involved the preparation of a concept and the implementation of an avionics data acquisition system intended for research during flight of unmanned aerial vehicles of the mini class, this article presents a design of an avionics system and describes equipment solutions of a distributed measurement system intended for data acquisition consisting of intelligent transducers. The data collected during a flight controlled by an operator confirmed proper operation of the individual components of the data acquisition system.

  15. Efficient design and operation of a data acquisition system for pressurized pipeline systems.

    Science.gov (United States)

    Kim, S

    2006-01-01

    The unsteady flow analysis of pipeline systems provides useful guidelines for implementing data acquisition components such as data filtering ranges, sensor locations and sampling frequencies. A theoretical integration among hydraulics, free vibration analysis and signal processing is proposed for a comprehensive approach aiming at enhanced design and operation of data acquisition system. Transient analysis is performed to extract flow variation by a valve modulation in a pipeline system. Frequency transformation analysis is developed to convert pressure variations between time domain and frequency domain. Free vibration analysis provides spatial distribution of impedance characteristics and pressure variation for determining optimum sensor location. A real-time filter can be designed to secure valid signals of any particular unsteady event. Hypothetical and experimental applications show that the proposed method has potentials of the leakage detection of a pipeline system as well as an efficient design of data acquisition system.

  16. HL-1 tokamak data acquisition system and its initial application in the physical experiment

    International Nuclear Information System (INIS)

    Deng Huichen; Fu Bo; Dong Jiafu

    1989-11-01

    A HL-1 tokamak data acquisition system has been developed and has been used in the physical experiment. The hardware and software configuration of the system, as well as the typical acquired data in the HL-1 experiment are introduced

  17. Design and construction of a data acquisition system for a neutron diffractometer

    International Nuclear Information System (INIS)

    Baeza F, Lorena M.

    1995-01-01

    This work presents the design and construction of a data acquisition system for the neutron diffractometer of the La Reina Nuclear Studies Center. The system counts simultaneously the events produced in 17 detection channels, in 128 time channels with 10 μs duration, synchronized with a external signal. The event counting is performed by associating each detection and time channel to a binary code which determine a storage memory. The system is operated by a computer which controls the data acquisition and transfer. The designed software allows the data acquisition and storage in a file for later processing

  18. SensorKit: A Flexible and Extensible System for In-Situ Data Acquisition

    Science.gov (United States)

    Silva, F.; Deschon, A.; Chang, J.; Westrich, S.; Cho, Y. H.; Gullapalli, S.; Benzel, T.; Graham, E. A.

    2009-12-01

    Over the years, sensor networks technology has evolved tremendously and has great potential in environmental sensing applications. However, because sensor networks are usually designed and built by computer scientists and engineers with little input from the scientific community, the resulting technology is often complex and out of reach for most field scientists. A few sensor, and data logger vendors have released data acquisition systems that can be used with their products. Unfortunately, these are generally vendor-specific, requiring scientists with heterogeneous sensors to use multiple systems to acquire data from all their sensors. A few, more generic systems, are compatible with multiple brands. However, these often offer only limited functionality, little flexibility, and no extensibility. We built SensorKit to overcome these limitations and to accelerate the adoption of sensor networks by field scientists. Using a simplicity-through-sophistication approach, we provide scientists with a powerful tool for field data collection. SensorKit is hardware agnostic, and was built using commercial off-the-shelf components. By employing a Linux-based ultra low-power generic embedded processing platform with a variety of dataloggers (including Berkeley motes, National Instruments' Compact RIOs, as well as legacy and newer PakBus-based Campbell data loggers), we support requirements from a large number of scientists. The user interfaces are designed to be intuitive so that most scientists can deploy, configure, and operate the system without extensive training. Working in close collaboration with field scientists allowed us to better understand scientific requirements and ensure system relevancy. The requirements for data acquisition, data storage, and data communication vary significantly for each deployment. Data acquisition needs to include capabilities for different analog, digital, and other complex sensors (e.g. cameras, and robotic sensors). Moreover, the

  19. ICH rf system data acquisition and real time control using a microcomputer system

    International Nuclear Information System (INIS)

    Cary, W.P.; Allen, J.A.; Pinsker, R.I.; Petty, C.C.

    1993-10-01

    On the basis of the rapidly increasing power, speed, and decreasing cost of the personal computer (microcomputer) it was felt that a real time data acquisition and control system could be configured quickly and very cost effectively. It was further felt that by using a high level or object-oriented programming language that considerable time and expense could be saved and at the same time increase system flexibility. This paper will attempt to address the desired system requirements and performance for both the control of the high power transmitters and for the data acquisition and presentation of the information

  20. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    Energy Technology Data Exchange (ETDEWEB)

    Wheat, Jr., Robert Mitchell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

  1. DAPHNE: a parallel multiprocessor data acquisition system for nuclear physics. [Data Acquisition by Parallel Histogramming and NEtworking

    Energy Technology Data Exchange (ETDEWEB)

    Welch, L.C.

    1984-01-01

    This paper describes a project to meet these data acquisition needs for a new accelerator, ATLAS, being built at Argonne National Laboratory. ATLAS is a heavy-ion linear superconducting accelerator providing beam energies up to 25 MeV/A with a relative spread in beam energy as good as .0001 and a time spread of less than 100 psec. Details about the hardware front end, command language, data structure, and the flow of event treatment are covered.

  2. A high-performance data acquisition system for computer-based multichannel analyzer

    International Nuclear Information System (INIS)

    Zhou Xinzhi; Bai Rongsheng; Wen Liangbi; Huang Yanwen

    1996-01-01

    A high-performance data acquisition system applied in the multichannel analyzer is designed with single-chip microcomputer system. The paper proposes the principle and the method of realizing the simultaneous data acquisition, the data pre-processing, and the fast bidirectional data transfer by means of direct memory access based on dual-port RAM as well. The measurement for dead or live time of ADC system can also be implemented efficiently by using it

  3. A distributed high speed data acquisition system for KT5C tokamak

    International Nuclear Information System (INIS)

    Sun Xiang; Wang Zhijiang; Lu Ronghua; Wang Jun; Yu Yi; Zhu Zhenghua; Wen Yizhi; Wan Shude; Liu Wandong; Yu Changxuan

    2005-01-01

    The development of a distributed data acquisition system with low cost to implement high speed data collection through the campus networks for a small tokamak, KT5C, is presented. Data of 512 k bytes at 5 MHz from 5 channels for each can be collected during about 10s after three researchers at different positions demand this system for acquisitions. This system realizes long distance multiuser operations; virtually efficiency of the data acquisition is enhanced. (authors)

  4. Report on a field-portable VME-based distributed data acquisition system

    International Nuclear Information System (INIS)

    Drigert, M.W.; Cole, J.D.; Reber, E.L.; Young, J.M.

    1996-01-01

    A development effort was started two years ago to develop a portable data acquisition system which could be used for performing arms control verification and environmental monitoring measurements with complex multi-detector systems in the field. A field portable data acquisition system has been developed around a VMEbus based micro-processor and standard TCP/IP network protocols. The hardware consists of a compact VME crate and a single CAMAC crate containing the signal processing electronics. The component processes of the data acquisition system transfer control and event data over a set of TCP/IP socket connections. The use of network sockets for the interprocess communications allows the data acquisition system to be operated transparently on one workstation or on a number of workstations distributed around a local network

  5. Design of data acquisition system for 2D-ARRAY ionization chamber detector

    International Nuclear Information System (INIS)

    He Chaohui; Xing Guilai; Wu Zhifang; Wang Zhentao

    2012-01-01

    The introduction is given on the design and development of data acquisition system for 2D-ARRAY ionization chamber detector, which is used for dose verification of tumor radiotherapy. The paper describes the structure and the principle of the 2D-ARRAY ionization chamber detector system in detail, and focuses on the discussion on the design process of the detector's data acquisition system and the development of data acquisition system which is constituted by preamplifier, preamplifier control board and data acquisition board. The client can setup the parameters of the detector system via TCP/IP and do data processing such as high speed data collection and acquisition, further operation and so on. (authors)

  6. Development of an automatic sample changer and a data acquisition system

    International Nuclear Information System (INIS)

    Bianchini, Ricardo M.; Estevez, Jorge; Vollmer, Alberto E.; Iglicki, Flora A.

    1999-01-01

    An automatic electro-pneumatic sample changer with a rotating sample holder is described. The changer is coupled through an electronic interface with the data acquisition station. The software to automate the system has been designed. (author)

  7. Data Acquisition System Based in MDAS Unit for the FEBEX Project

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J.M.; Navarrete, J.J.; Martin, P.L.

    1998-01-01

    The engineered barrier concept for the storage of radioactive wastes is being tested at CIEMAT facilities. This document describes the data acquisition system of one of that experiments. (Author) 2 refs

  8. The upgrade for the data acquisition system of the KOTO detector

    Energy Technology Data Exchange (ETDEWEB)

    Tecchio, M., E-mail: tecchio@umich.edu [University of Michigan, Ann Arbor, MI (United States); Beechert, J.; Campbell, M. [University of Michigan, Ann Arbor, MI (United States); Huff, M. [Kenyon College, Gambier, OH (United States); Micallef, J.; Rymph, C.; Schamis, H.; Su, S. [University of Michigan, Ann Arbor, MI (United States); Xu, J. [Apple Inc., Cupertino, CA (United States)

    2016-07-11

    A major upgrade to the KOTO detector data acquisition system based on the ATCA standard is being considered. The ATCA standard provides a natural solution to the current KOTO constraints, including communication between boards and higher input and output bandwidth.

  9. A system design of data acquisition and processing for side-scatter lidar

    Science.gov (United States)

    Zhang, ZhanYe; Xie, ChenBo; Wang, ZhenZhu; Kuang, ZhiQiang; Deng, Qian; Tao, ZongMing; Liu, Dong; Wang, Yingjian

    2018-03-01

    A system for collecting data of Side-Scatter lidar based on Charge Coupled Device (CCD),is designed and implemented. The system of data acquisition is based on Microsoft. Net structure and the language of C# is used to call dynamic link library (DLL) of CCD for realization of the real-time data acquisition and processing. The software stores data as txt file for post data acquisition and analysis. The system has ability to operate CCD device in all-day, automatic, continuous and high frequency data acquisition and processing conditions, which will catch 24-hour information of the atmospheric scatter's light intensity and retrieve the spatial and temporal properties of aerosol particles. The experimental result shows that the system is convenient to observe the aerosol optical characteristics near surface.

  10. Distributed SCI-based data acquisition systems constructed from SCI bridges and SCI switches

    International Nuclear Information System (INIS)

    Wu Bin; Kristiansen, E.; Skaali, B.; Bogaerts, A.; Divia, R.; ); Perea, E.

    1994-01-01

    The IEEE standard 1596-1992, Scalable Coherent Interface (SCI) provides novel possibilities to build data acquisition systems for large and very high rate experiments in high energy physics. The RD24 project at CERN started two years ago to investigate applications of SCI to data acquisition at the Large Hadron Collider (LHC). As part of the RD24 project, simulation of large SCI-based data acquisition systems is performed by a simulator written in the object-oriented language MODSIM II. The goal of this paper is to investigate the difference between SCI switch- and SCI-based systems, and to study some of the design criteria for the SCI switch element to form the interconnection of large scale SCI-based data acquisition systems. 15 refs., 14 figs., 2 tabs

  11. Beam diagnostics and data acquisition system for ion beam transport line used in applied research

    International Nuclear Information System (INIS)

    Skuratov, V.A.; Didyk, A.Yu.; Arkhipov, A.V.; Illes, A.; Bodnar, K.; Illes, Z.; Havancsak, K.

    1999-01-01

    Ion beam transport line for applied research on U-400 cyclotron, beam diagnostics and data acquisition system for condensed matter studies are described. The main features of Windows-based real time program are considered

  12. The upgrade for the data acquisition system of the KOTO detector

    International Nuclear Information System (INIS)

    Tecchio, M.; Beechert, J.; Campbell, M.; Huff, M.; Micallef, J.; Rymph, C.; Schamis, H.; Su, S.; Xu, J.

    2016-01-01

    A major upgrade to the KOTO detector data acquisition system based on the ATCA standard is being considered. The ATCA standard provides a natural solution to the current KOTO constraints, including communication between boards and higher input and output bandwidth.

  13. Computer software design description for the integrated control and data acquisition system LDUA system

    International Nuclear Information System (INIS)

    Aftanas, B.L.

    1998-01-01

    This Computer Software Design Description (CSDD) document provides the overview of the software design for all the software that is part of the integrated control and data acquisition system of the Light Duty Utility Arm System (LDUA). It describes the major software components and how they interface. It also references the documents that contain the detailed design description of the components

  14. SHIVA - A multitask data acquisition system for the Oslo University cyclotron laboratory

    International Nuclear Information System (INIS)

    Skaali, B.; Haugen, A.; Ingebretsen, F.; Midttun, G.

    1983-01-01

    The authors describe a general nuclear data acquisition system implemented on a minicomputer using the standard facilities of a real time operating system. The CAMAC data acquisition hardware is controlled by a high speed ADC scanner module. Sorting of multiparameter data is based on a flexible Transformation Of Nuclear Event (TONE) language. The data processing rate, including tape transfer, is several thousand events/s, depending on the complexity of the sorting program

  15. SAMS: The synchronization and monitoring system for ATF [Advanced Toroidal Facility] data acquisition

    International Nuclear Information System (INIS)

    Greenwood, D.E.

    1987-01-01

    SAMS performs much of the synchronization of the distributed data acquisition system for the Advanced Toroidal Facility (ATF). SAMS is responsible for propagating shot information and managing te data system directories and logical names. This paper describes how SAMS communicates with other processes, both within the VAX cluster that supports most of the ATF data acquisition and on VAXes that are connected to the cluster via DECnet. 3 refs

  16. Optic fibber data acquisition and transmission system dedicated to a neutron generator

    International Nuclear Information System (INIS)

    Ledo Pereda, Luis Miguel; Vergara Limon, Sergio; Arteche Diaz, Raul

    2009-01-01

    Hereby, are presented the design, construction and application of a virtual data acquisition system based on the usage of microcontrollers, optic fibber, and PC. System is aimed to the reestablishment of the communication between the basic modules of a Neutron Generator. The work shows, how the original interface design is upgraded by the automation of the data acquisition, on the Neutron Generator exploitation parameters. The PC usage is being introduced in the Neutron Generator and the precedent is established for further subsystem

  17. Development of an optical beam system for deep sea data acquisition

    International Nuclear Information System (INIS)

    Shibata, Yozo

    1994-01-01

    Remotely Operated Vehicles (ROV) are an ideal method for acquiring data from instruments located on the seabed. Electrical, acoustic or optical signals can be used to communicate with the data acquisition system. While optical signals have high capacity, the power of the optical beam decreases rapidly with distance in sea water; however, the ROV's ability to approach the instruments eliminates this problem. To investigate a feasibility of an optical beam system for underwater data acquisition, the author has developed and manufactured a prototype data acquisition instrument which the ROV can control. Based on the communication test results, he concludes that such a system is a practical means of short-range underwater data acquisition

  18. Data acquisition system for linear position sensitive detector based neutron diffractometer

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Behere, A.; Prafulla, S.; Srivastava, V.D.; Mukhopadhyaya, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2003-03-01

    This data acquisition system is developed to serve the requirements of various linear 1PSD based neutron diffractometers. A neutron diffractometer uses a neutron beam as a probe to study the crystallographic properties of materials. Presently two multi-PSD and two single-PSD diffractometers are commissioned and a few more are being installed in Dhruva. This data acquisition system is installed at each of these - diffractometers. Different requirements of individual diffractometers were studied and reconciled to design a single data acquisition system, which can be easily configured or customized for individual setups. The charge division in a linear PSD is converted to a position output with the help of an RDC (Ratio ADC). The ftont-end electronics, which consist of preamplifiers and shaping amplifiers, provide an interface between a PSD and an RDC. A PC add-on card is designed around a Transputer. It can interface 16 RDCs, a few motor controls and on/off controls. Data acquisition and other controls are implemented in the Transputer program. A front-end Windows98 application merges the raw data of different RDCs to obtain the equiangular data. Through software the data acquisition system can be configured for diffetent diffractometers. Commercially available hardware is also integrated as,a part of the data acquisition system in some of the setups. The data acquisition system is working reliably as a part of two single PSD and two multi-PSD diffractometers. It can handle data rates upto 15 K/Sec without any loss of counts. It has played a significant role in providing improved throughput and utilization ofvarious diffractometers. The'data acquisition system and its different applications are presented in this report. (author)

  19. A data acquisition system based on general VME system in WinXP

    International Nuclear Information System (INIS)

    Ning Zhe; Qian Sen; Wang Yifang; Heng Yuekun; Zhang Jiawei; Fu Zaiwei; Qi Ming; Zheng Yangheng

    2010-01-01

    The compilation and encapsulation of a general data acquisition system based on VME board in WinXP environment was developed using LabVIEW with graphics interface. By integrating the emulational instrument panel of LabVIEW and calling the Dynamic Link Libraries (DLLs) of crate controller, the VME modules were encapsulated into function modules independently, for convenience of use. The BLT, MBLT and CBLT readout modes for different VME boards were studied. The modules can be selected and modified easily according to the requirements of different tests. Finally, successful applications of the high resolution data acquisition software (DAQ) in several experiment environments are reported.(authors)

  20. Low Power Computing in Distributed Systems

    Science.gov (United States)

    2006-04-01

    performance applications. It has been adopted in embedded systems such as the Stargate from Crossbow [15] and the PASTA 4 0 0.1 0.2 0.3 0.4 (A) flo at...current consumption of the Stargate board is measured by an Agilent digital multimeter 34401A. The digital multimeter is connected with the PC for data...floating point operation vs. integer operation Power supply Digital multimeter Stargate board with Xscale processor 5 2.2 Library math function vs

  1. The data-acquisition and second level trigger system for the ZEUS calorimeter

    International Nuclear Information System (INIS)

    Lugt, H.J. van der.

    1993-01-01

    ZEUS and HERA are introduced in chapter 1 with emphasis on the ZEUS Calorimeter and the ZEUS trigger system. The analog and digital electronics developed for the readout of the Calorimeter signals, and the hardware for the Calorimeter Second Level Trigger and data-acquisition system, is described in chapter 2. Emphasis is put on the hardware developed at NIKHEF, which is based on the transputer as the main processing element. The ZEUS trigger and data-acquisition environment as well as the calibration procedures needed for the Calorimeter impose several requirements on the design of the data-acquisition system. The requirements, their implications for the design of the transputer network architecture and the design itself, are described in detail in chapter 3. The software developed for the Calorimeter data-acquisition is described in chapter 4. It includes both the software for the Calorimeter data-acquisition as that required for the calibration of the Calorimeter. First experiences with the CAL-SLT algorithms, obtained during the 1992 HERA running periods, are presented in chapter 5. Chapter 6 discusses the performance of the Calorimeter data-acquisition system. (orig.)

  2. Design of Real Time Data Acquisition System Framework for Production Workshop Based on OPC Technology

    OpenAIRE

    Yue-xin Yang; Gong-chang Ren

    2017-01-01

    In this paper, the low level of production management information in a hydraulic torque converter enterprise is presented. It is needed to develop a digital assembly shop MES to solve this problem. There is a high demand for the real-time data acquisition of the production line in the digital assembly shop MES. According to the actual needs of MES in digital assembly workshop, a real time data acquisition system framework based on OPC technology and database technology is proposed. The framew...

  3. Automated data acquisition and analysis system for inventory verification

    International Nuclear Information System (INIS)

    Sorenson, R.J.; Kaye, J.H.

    1974-03-01

    A real-time system is proposed which would allow CLO Safeguards Branch to conduct a meaningful inventory verification using a variety of NDA instruments. The overall system would include the NDA instruments, automated data handling equipment, and a vehicle to house and transport the instruments and equipment. For the purpose of the preliminary cost estimate a specific data handling system and vehicle were required. A Tracor Northern TN-11 data handling system including a PDP-11 minicomputer and a measurement vehicle similar to the Commission's Regulatory Region I van were used. The basic system is currently estimated to cost about $100,000, and future add-ons which would expand the systems' capabilities are estimated to cost about $40,000. The concept of using a vehicle in order to permanently rack mount the data handling equipmentoffers a number of benefits such as control of equipment environment and allowance for improvements, expansion, and flexibility in the system. Justification is also presented for local design and assembly of the overall system. A summary of the demonstration system which illustrates the advantages and feasibility of the overall system is included in this discussion. Two ideas are discussed which are not considered to be viable alternatives to the proposed system: addition of the data handling capabilities to the semiportable ''cart'' and use of a telephone link to a large computer center

  4. Study on data acquisition system based on reconfigurable cache technology

    Science.gov (United States)

    Zhang, Qinchuan; Li, Min; Jiang, Jun

    2018-03-01

    Waveform capture rate is one of the key features of digital acquisition systems, which represents the waveform processing capability of the system in a unit time. The higher the waveform capture rate is, the larger the chance to capture elusive events is and the more reliable the test result is. First, this paper analyzes the impact of several factors on the waveform capture rate of the system, then the novel technology based on reconfigurable cache is further proposed to optimize system architecture, and the simulation results show that the signal-to-noise ratio of signal, capacity, and structure of cache have significant effects on the waveform capture rate. Finally, the technology is demonstrated by the engineering practice, and the results show that the waveform capture rate of the system is improved substantially without significant increase of system's cost, and the technology proposed has a broad application prospect.

  5. A multifunctional data acquisition and processing system based on microcomputer

    International Nuclear Information System (INIS)

    Chen Huaide; Pan Dajing; Zhu Cuiqin

    1988-01-01

    Introduced herein is a multifunctional MCA-computer system which can operate as a foreground and a background with capabilities of high resolution in γ-ray spectrum analysis, multiplex multi-scale, multi-scale, and the display system with resolution being high up to 8192 points. The MCA has 8192 channels with 20 bits and 8k buffer memory. Firstly, the acquisition data is stored into the buffer memory and then transformed into computer for processing. The system software consists of the management software, spectrum processing and multiplex multi-scale measurement software. The block diagram of the system, the specifications and testing results are given

  6. Development of new data acquisition system for COMPASS experiment

    Science.gov (United States)

    Bodlak, M.; Frolov, V.; Jary, V.; Huber, S.; Konorov, I.; Levit, D.; Novy, J.; Salac, R.; Virius, M.

    2016-04-01

    This paper presents development and recent status of the new data acquisiton system of the COMPASS experiment at CERN with up to 50 kHz trigger rate and 36 kB average event size during 10 second period with beam followed by approximately 40 second period without beam. In the original DAQ, the event building is performed by software deployed on switched computer network, moreover the data readout is based on deprecated PCI technology; the new system replaces the event building network with a custom FPGA-based hardware. The custom cards are introduced and advantages of the FPGA technology for DAQ related tasks are discussed. In this paper, we focus on the software part that is mainly responsible for control and monitoring. The most of the system can run as slow control; only readout process has realtime requirements. The design of the software is built on state machines that are implemented using the Qt framework; communication between remote nodes that form the software architecture is based on the DIM library and IPBus technology. Furthermore, PHP and JS languages are used to maintain system configuration; the MySQL database was selected as storage for both configuration of the system and system messages. The system has been design with maximum throughput of 1500 MB/s and large buffering ability used to spread load on readout computers over longer period of time. Great emphasis is put on data latency, data consistency, and even timing checks which are done at each stage of event assembly. System collects results of these checks which together with special data format allows the software to localize origin of problems in data transmission process. A prototype version of the system has already been developed and tested the new system fulfills all given requirements. It is expected that the full-scale version of the system will be finalized in June 2014 and deployed on September provided that tests with cosmic run succeed.

  7. A data acquisition system for a radionuclide laboratory

    International Nuclear Information System (INIS)

    Reher, D.; Idzerda, A.B.

    1984-01-01

    The concept and installation of a computer system for use in a radionuclide laboratory is described. It consists of a hierarchical star network of distributed intelligence. The system installation was spread over several years in three phases which made an economical solution possible. (orig.)

  8. Distributed Wireless Data Acquisition System with Synchronized Data Flow

    CERN Document Server

    Astakhova, N V; Dikoussar, N D; Eremin, G I; Gerasimov, A V; Ivanov, A I; Kryukov, Yu S; Mazny, N G; Ryabchun, O V; Salamatin, I M

    2006-01-01

    New methods to provide succession of computer codes under changes of the class of problems and to integrate the drivers of special-purpose devices into application are devised. The worked out scheme and methods for constructing automation systems are used to elaborate a distributed wireless system intended for registration of the characteristics of pulse processes with synchronized data flow, transmitted over a radio channel. The equipment with a sampling frequency of 20 kHz allowed us to achieve a synchronization accuracy of up to $\\pm $ 50 $\\mu$s. Modification of part of the equipment (sampling frequency) permits one to improve the accuracy up to 0.1 $\\mu$s. The obtained results can be applied to develop systems for monitoring various objects, as well as automation systems for experiments and automated process control systems.

  9. Development of Data Acquisition System for Wind Energy Applications

    OpenAIRE

    西本,澄

    1992-01-01

    A Data acquisiton system developed for wind energy applications will be described in this paper. This system is composed of an anemometer with two blades downwind and a computer which processes wind data. Wind energy calculated from an average wind speed is inaccurate, since wind power increases with the cube of wind velocity. To decide the design and the site for a wind turbine system, it is very important to consider wind data on a long term basis, that is the total wind energy and distribu...

  10. Transmission computed tomography data acquisition with a SPECT system

    International Nuclear Information System (INIS)

    Greer, K.L.; Harris, C.C.; Jaszczak, R.J.; Coleman, R.E.; Hedlund, L.W.; Floyd, C.E.; Manglos, S.H.

    1987-01-01

    Phantom and animal transmission computed tomography (TCT) scans were performed with a camera-based single photon emission computed tomography (SPECT) system to determine system linearity as a function of object density, which is important in the accurate determination of attenuation coefficients for SPECT attenuation compensation. Results from phantoms showed promise in providing a linear relationship in measuring density while maintaining good image resolution. Animal images were essentially free of artifacts. Transmission computed tomography scans derived from a SPECT system appear to have the potential to provide data suitable for incorporation in an attenuation compensation algorithm at relatively low (calculated) radiation doses to the subjects

  11. Automatic data acquisition system for a photovoltaic solar plant

    Energy Technology Data Exchange (ETDEWEB)

    Santos, A.; Barrio, C.L.; Guerra, A.G.

    1986-01-01

    An autonomous monitoring system for photovoltaic solar plants is described. The system is able to collect data about the plant's physical and electrical characteristics and also about the environmental conditions. It may present the results on a display, if requested, but its main function is measuring periodically a set of parameters, including several points in the panel I-V characteristics, in an unattended mode. The data are stored on a magnetic tape for later processing on a computer. The system hardware and software are described, as well as their main functions.

  12. A data-acquisition and processing system for Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Fever, H.Th. le

    1979-01-01

    A state of the art data-aquisition system for four simultaneous and independent Moessbauer experiments has been implemented utilizing a general purpose minicomputer and low cost microprocessors. In this system, the microprocessors are dedicated to real-time data collection from the experiments while the minicomputer is being utilized for controlling the microprocessors and processing the data. Extensive consideration was given in the design of the system to achieve the most advantageous balance between hardware and software, i.e. to maintain the ease of handling and full capability of hardwired systems without employing sophisticated hardware. The concept of the design is independent of the type of processor, and may be applied to other experiments requiring real-time data collection and off-line data processing facilities. (Auth.)

  13. FireSignal-Data acquisition and control system software

    Energy Technology Data Exchange (ETDEWEB)

    Neto, A. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal)], E-mail: andre.neto@cfn.ist.utl.pt; Fernandes, H.; Duarte, A.; Carvalho, B.B.; Sousa, J.; Valcarcel, D.F. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal); Hron, M. [Asociace EURATOM IPP.CR, Prague (Czech Republic); Varandas, C.A.F. [Associacao Euratom/IST, Centro de Fusao Nuclear, Av. Rovisco Pais, P-1049-001 Lisboa (Portugal)

    2007-10-15

    Control of fusion experiments requires non-ambiguous, easy to use, user-interfaces to configure hardware devices. With that aim, a highly generic system for data control and acquisition has been developed. Among the main features it allows remote hardware configuration, shot launching, data sharing between connected users and experiment monitoring. The system is fully distributed: the hardware driver nodes, clients and servers are completely independent from each other and might run in different operating systems and programmed in different languages. All the communication is provided through the Common Object Request Broker Architecture (CORBA) protocol. FireSignal is designed to be as independent as possible from any kind of constraints as it is a plugin based system. Database, data viewers and the security system are some examples of what can easily be changed and adapted to the target machine's needs. In this system, every hardware is described in eXtensible Markup Language (XML) and with this information Graphical User Interfaces (GUI) are automatically built and user's parameter configuration validated. Any type of hardware device can be integrated in the system as long as it is described in XML and the respective driver developed. Any modern programming language can be used to develop these drivers. Currently Python and Java generic drivers are used. Data storage and indexing is time stamp event-based. Nodes are responsible for tagging the acquired samples with the absolute time stamps and to react to machine events. FireSignal is currently being used to control the ISTTOK/PT and CASTOR/CZ tokamaks.

  14. FireSignal-Data acquisition and control system software

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Duarte, A.; Carvalho, B.B.; Sousa, J.; Valcarcel, D.F.; Hron, M.; Varandas, C.A.F.

    2007-01-01

    Control of fusion experiments requires non-ambiguous, easy to use, user-interfaces to configure hardware devices. With that aim, a highly generic system for data control and acquisition has been developed. Among the main features it allows remote hardware configuration, shot launching, data sharing between connected users and experiment monitoring. The system is fully distributed: the hardware driver nodes, clients and servers are completely independent from each other and might run in different operating systems and programmed in different languages. All the communication is provided through the Common Object Request Broker Architecture (CORBA) protocol. FireSignal is designed to be as independent as possible from any kind of constraints as it is a plugin based system. Database, data viewers and the security system are some examples of what can easily be changed and adapted to the target machine's needs. In this system, every hardware is described in eXtensible Markup Language (XML) and with this information Graphical User Interfaces (GUI) are automatically built and user's parameter configuration validated. Any type of hardware device can be integrated in the system as long as it is described in XML and the respective driver developed. Any modern programming language can be used to develop these drivers. Currently Python and Java generic drivers are used. Data storage and indexing is time stamp event-based. Nodes are responsible for tagging the acquired samples with the absolute time stamps and to react to machine events. FireSignal is currently being used to control the ISTTOK/PT and CASTOR/CZ tokamaks

  15. The BTeV trigger and data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Butler, Joel N.; /Fermilab

    2004-10-01

    The BTeV trigger inspects every beam crossing of the Fermilab Tevatron, running at a luminosity of 2 x 10{sup 32}/cm{sup 2}-s, and selects events that have ''detached vertices'' from B decays occurring downstream of the main interaction. The system uses a massively parallel system of FPGAs and microprocessors to produce a trigger decision on average every 396 ns. The trigger calculations are facilitated by the 23 Million channel pixel detector that provides the input to the trigger. Front end electronics sparsifies the remainder of event data and sends it to large, Tbyte, memory buffers that store it until the trigger decision can be made. This complex system presents special challenges in fault monitoring and power and cooling.

  16. The MTX [Microwave Tokamak Experiment] data acquisition system

    International Nuclear Information System (INIS)

    Butner, D.N.; Drlik, M.; Brown, M.D.; Casper, T.A.; Meyer, W.H.; Moller, J.M.

    1989-01-01

    The diagnostic data from the MTX experiment is acquired and processed by an expandable, distributed, multivendor computer network. The system blends a variety of software into a coordinated, unified, and highly flexible design. Using modular software design techniques, we created a system stressing distributed processing, portability, and transparent data access. In our approach to modularity, we standardized communication interfaces between modules and separated generic tasks from machine and application-specific implementations. For flexible distributed processing, we used modular, portable software and LLNL facility that provides an interprocess communication system (IPCS) in the multivendor network. With transparent data access, any program can access data stored anywhere in the network without knowing the specific location. The computer hardware includes a DEC VAX cluster, HP workstations and HP desktop computers. We are using commercial software in addition to packages from MIT, ORNL, and LLNL. 4 refs., 4 figs

  17. FireSignal - Data Acquisition and Control System Software

    International Nuclear Information System (INIS)

    Neto, A.; Fernandes, H.; Duarte, A.; Carvalho, B.; Sousa, J.; Valcarcel, D.; Varandas, C.; Hron, M.

    2006-01-01

    Control of fusion devices requires good, non-ambiguous, easy to use user-interfaces to configure hardware devices. To solve this problem a highly generic system for data control and acquisition has been developed. Among the main features it allows remote hardware configuration, shot launching, data sharing between connected users and experiment monitoring. The system is fully distributed: the hardware driver nodes, clients and server are completely independent from each other and might be running in different operating systems and programmed in different languages. All the communication is provided through the Common Object Request Broker Architecture (CORBA) protocol. FireSignal was designed from the beginning to be as independent as possible from any kind of constraints as it's a plugin based system. Database, data viewers and the security system are some examples of what can easily be changed and adapted to the target machine's needs. All hardware is described in eXtendend Markup Language (XML) and from this information the FireSignal client application can build automatically Graphical User Interfaces (GUI) and validate the user's parameter configuration. Any type of hardware can be integrated in the system as long as it is described in XML and the respective driver is developed. Any modern programming language can be used to develop these drivers, and currently we use Python and Java generic drivers. All data storage and indexing is time stamped event-based s. Nodes are responsible for tagging the acquired samples with the absolute time stamps and to react to machine events. FireSignal is currently being used to control the ISTTOK/PT and CASTOR/CZ tokamaks. (author)

  18. Integrated systems for real time data acquisition and processing

    International Nuclear Information System (INIS)

    Oprea, I.; Oprea, M.

    1995-01-01

    The continuous measuring of all the nuclear and dosimetric parameters in a nuclear facility is essential for personnel and environment protection. Considering the vast amount of information and data required to keep an updated overview of a situation the need for an efficient acquisition processing and information system is evident. The paper analyses the special requirements as concerning the real time inter-process communication and proposes a modern concept based on the last trends existing in the field of computer technology and operating systems. (author)

  19. The data acquisition system for the HERA H1 experiment

    International Nuclear Information System (INIS)

    Haynes, W.J.

    1990-06-01

    The HERA ep collider will set new challenges for the acquisition of data from large particle physics experiments. Short bunch-crossing times combined with high data rates imply sophisticated designs based on current technology. This paper describes how a multi-microprocessor system is being used at the H1 experiment. (author)

  20. Integrated data acquisition system for coastal research vessel

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Desa, E.

    transportability. The data is logged on a central file server based on a Novell Netware operating system with fault tolerant features. Remote node communication allows easy access to data from shore-based LAN. The network supports microcontroller interface to log...

  1. Computerized system of data acquisition, primary processing and data storage

    International Nuclear Information System (INIS)

    Muniz, F.J.

    1981-05-01

    The present system was proposed in order to collect and conveniently document data alphanumeric. The application of this system in the nuclear area was motivated by the demand originated by the enviromental monitoring program in nuclear installations. This is possible due to the flexibility offered by the system, which can have a general purpose utilization, with exception of the normalization circuits. In the nuclear area the collected data will be basically meteorological, of use in the development of atmospheric diffusion models. The data will be useful to estimate the radiation doses to the public, resultant of accidental or routine liberation of radioactive material to the atmosphere. The evolution of the potential dose received by the public, resulting from a hypothetic reactor accident, could be calculated from these data, as well. The system, from the electronic point of view, utilizes scale large integration technology, being constitued basically by the following functional blocks: -Transducer, -Normalization circuits, -Analog multiplexer, -Analog digital converter, -Microprocessor, -Interface to cassette records, -Interface to cassette read, -Cassette. (Author) [pt

  2. A neutron time-of-flight data acquisition system

    International Nuclear Information System (INIS)

    Morris, D.V.

    1983-10-01

    A neutron time-of-flight scaler system is described for use with the Harwell Linac. The equipment is sufficiently versatile to be used with several types of computers although normally used with DEC PDP 11/45 and PDP 11/34. Using a combination of different input and memory boards most types of experiments can be accommodated. (author)

  3. Data acquisition system using a C 90-10 computer

    International Nuclear Information System (INIS)

    Smiljanic, Gabro

    1969-05-01

    The aim of this study is to make possible the acquisition of experimental data by the memory of a numerical calculator. These data come from analog-to-digital converters that analyze the amplitude of the pulses provided by detectors. Normally the computer executes its main program (data processing, transfer on magnetic tape, visualization, etc.). When information is available at the output of a converter, an interruption of the main program is requested, and after agreement a subroutine supports access to the information in the computer. The author has also considered the bi- and tri-parametric acquisition. The calculator and the converters are commercial devices (calculator C 90-10 from CII and converter CA 12 or CA 25 from Intertechnique), while the systems of adaptation of the input-output levels and the visualization were studied and realized at the CEA Saclay. An interface device was built to connect the converters; it's the cable part of the system. On the other hand, the programs necessary for the operation of the calculator have been studied and developed; it is the program aspect of the system. As far as possible the interface is designed to be universal, i.e. it must be able to work with other brands of equipment. The acquisition of the data is carried out in two phases: a) the converter expresses the amplitude of the input signal in the form of a binary number which is transferred into the interface at the same time as an interruption of the main program is asked. b) After acceptance of this interruption, the subprogram supports the transfer of the information of the interface in the computer, then adds a unit to the word located at the address determined from the information received. In other words, the system behaves like an amplitude analyzer whose operation is well known. But it is of a much more flexible use because of the possibilities of quick adaptation of the programs to the needs of the considered experiment, of the possibility to treat

  4. ATROPOS: a versatile data acquisition and analysis system

    International Nuclear Information System (INIS)

    Logg, C.A.; Cottrell, R.L.A.

    1978-10-01

    Versatile, portable, rugged, and compact test and control modules for use in the development and testing of detection equipment for high-energy physics experiments are frequently needed at SLAC. The basic system developed is based on an LSI-11 microcomputer with 24K RAM, 4K ROM, 2 serial interfaces (one to the console terminal, the other to the large SLAC IBM computer complex (the TRIPLEX)), a programable clock, and a CAMAC crate controller. Data logging support is provided for magnetic tape, floppy disk, and an interactive program (ACQUIRE) which runs on the TRIPLEX under the timesharing system ORVYL. Data are read from various CAMAC modules, collected, buffered, and optionally logged. At a lower priority, the data read are sampled and analyzed in real-time on the LSI-11 to produce various histograms and tables. Concurrently, a more extensive analysis can be performed by the TRIPLEX program on the data which are logged to it. Interactive facilities provided by the microcomputer operating system enable the user to change CAMAC module addresses and the function codes used with them, specify various data cuts and transformations that are to be performed on the sample data, and specify new histogram limits and titles. Results of the real-time analysis, by both the microcomputer and the TRIPLEX program (if it is attached), may be displayed in graphical or tabular form on the console terminal. The basic system hardware cost (exclusive of the magnetic tape drive and floppy disk drive) is around $7000. The software is written in a modular fashion so that the user can supply his own data reading and analysis routines. This system has been in use for two years by various groups on several LSI-11s at SLAC. 3 figures

  5. Automatic data acquisition system in CAMAC for spectrometry

    International Nuclear Information System (INIS)

    Szabo, L.; Szalay, S.; Takacz, P.; Pal, A.

    1981-01-01

    A special memory module with twofold access for spectrometric information is described. Via the direct access entry three regimes are realized: plus one, minus one and adress storage. The visual monitoring is carried out by means of an interface containing a buffer memory for the representation of 4 256-channel spectra and the text on the display. The system work is managed by a controller on the basis of a microprocessor

  6. Data acquisition system realization for H1 experiment

    International Nuclear Information System (INIS)

    Del Buono, L.

    1989-06-01

    The acquisition and trigger system for H1 liquid argon calorimeter deals with severe constraints which have to be taken into account. We describe the system which results from these constraints, emphasizing the solutions adopted to meet the specificities of the detector and the difficult experimental conditions at HERA: high physical background (10 4-5 Hz), physics and background events pile up (10%), large crossing frequency of proton and electron bunches (10.4 MHz). Next, we present a detailed description of the acquisition and online control scheme used during the calorimetry tests in SPS beam, at CERN. This test system, prefiguring the final one (which will start to work at the end of 1989), includes a fast frontal processor CAB (taking charge of the electronics read out and sequencing, and furthermore producing simple histograms). The CAB is controlled by a Micro Vax computer which realizes the user interface, allowing a quick visualisation and verification of the acquired data, these functions being performed in multitasking environment [fr

  7. Contribution to the design of an environmental data acquisition system

    International Nuclear Information System (INIS)

    RAZANAJATOVO, D.

    2005-01-01

    In the design of a data logger environmental parameters system, a significant part is the analogical processing signals from the sensor, in a word that the output signal dynamics corresponds to the range of the measured quantities physical as well as linearity of the response. Then a suitable calibration of each block is necessary to know the precision of the instruments. Finally, the calibration is represented into microprocessing language in a word that the instrument provides numerical value for the posting and the data storage. [fr

  8. New development of EPICS based data acquisition system for H-Alpha diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taegu, E-mail: glory@nfri.re.kr; Lee, Woongryol; Son, Souhun; Park, Jinseop

    2015-10-15

    Highlights: • The H-Alpha DAQ system was modified to measure the low current signal from the PMT. • We developed a new H-Alpha data acquisition system with a CPCI based digitizer. • We developed a signal conditioning box for converting the current to voltage. • The new signal condition box (SCB) has three input range level (400 nA, 1 μA and 2 μA). • It was successfully performed and stably operates more than the previous DAQ system. - Abstract: The H-Alpha diagnostic system has been developed to measure the line integrated intensity in the direction of toroidal and poloidal. The data acquisition (DAQ) system for H-Alpha diagnostics of the Korea Superconducting Tokamak Advanced Research (KSTAR) at the beginning of the first plasma in 2008 was developed with VME form factor digitizer in the Linux OS platform. The VME digitizer module of H-Alpha data acquisition system was modified to measure the low current signal from the photo-multiplier tubes (PMT). The input maximum current values of modified digitizer module are 400 nA and low current data is expressed as the value of the voltage between −10 V and +10 V. At first time, there was no problem to measure H-Alpha signal, but it could not measure the H-Alpha data signal as the KSTAR Plasma density increased. It exceeds digitizer input range, which means the H-Alpha signal is over 400 nA, so we should manually change the resistor on the digitizer board to measure the 400 nA over current. This is not easy to do and showed instability in the long time operation with high sampling data acquisition. In order to overcome these weak points, a new H-Alpha data acquisition system has been developed with a compact PCI (cPCI) based digitizer and a signal conditioning box for converting the current to voltage in the Linux OS platform. The new data acquisition system was developed based on Experimental Physics and Industrial Control System (EPICS) framework like other KSTAR diagnostics with standard framework (SFW

  9. Large Distributed Data Acquisition System at the Z Facility

    International Nuclear Information System (INIS)

    Mills, Jerry A.; Potter, James E.

    1999-01-01

    Experiments at the Z machine generate over four hundred channels of waveform data on each accelerator shot. Most experiments require timing accuracy to better than one nanosecond between multiple distributed recording locations throughout the facility. Experimental diagnostics and high speed data recording equipment are typically located within a few meters of the 200 to 300 terawatt X- ray source produced during Z-pinch experiments. This paper will discuss techniques used to resolve the timing of the several hundred data channels acquired on each shot event and system features which allow viewing of waveforms within a few minutes after a shot. Methods for acquiring high bandwidth signals in a severe noise environment will also be discussed

  10. A Novel Data Acquisition System Based on Fast Optical Links and Universal Readout Boards

    CERN Document Server

    Korcyl, Grzegorz

    2015-01-01

    Various scale measurement systems are composed of the sensors providing data through the data acquisition system to the archiving facility. The scale of such systems is determined by the number of sensors that require processing and can vary from few up to hundreds of thousands. The number and the type of sensors impose several requirements on the data acquisition system like readout frequency, measurement precision and online analysis algorithms. The most challenging application s are the large scale experiments in nuclear and particle physics . This thesis presents a concept , construction and tests of a modular and scalable, tree - structured architecture of a data acquisition system. The system is composed out of two logical elemen ts: endpoints which are the modules providing data and hubs that concentrate the data streams from the endpoints and provide connectivity with the rest of the system. Those two logica...

  11. Embedded systems design for high-speed data acquisition and control

    CERN Document Server

    Di Paolo Emilio, Maurizio

    2015-01-01

    This book serves as a practical guide for practicing engineers who need to design embedded systems for high-speed data acquisition and control systems. A minimum amount of theory is presented, along with a review of analog and digital electronics, followed by detailed explanations of essential topics in hardware design and software development. The discussion of hardware focuses on microcontroller design (ARM microcontrollers and FPGAs), techniques of embedded design, high speed data acquisition (DAQ) and control systems. Coverage of software development includes main programming techniques, culminating in the study of real-time operating systems. All concepts are introduced in a manner to be highly-accessible to practicing engineers and lead to the practical implementation of an embedded board that can be used in various industrial fields as a control system and high speed data acquisition system.   • Describes fundamentals of embedded systems design in an accessible manner; • Takes a problem-solving ...

  12. Development of a VME and CAMAC based data acquisition and transfer system for JT-60 control

    International Nuclear Information System (INIS)

    Totsuka, Toshiyuki

    1993-08-01

    Development of a VME and CAMAC based data acquisition and transfer system for JT-60 Control is reported. The present data acquisition and transfer system in JT-60 control is basically composed of CAMAC devices. Since the system equipped with 16-bit microcomputers was manufactured more than ten years ago, the performance and program development environment of the system are apparently worse than those of modern 32-bit microcomputers. To improve these disadvantages, a new data acquisition and transfer system using VME-based 32-bit microcomputers and CAMAC drivers is under design. Corresponding to this design, a CAMAC handler, which runs on the microcomputer, for the VME based CAMAC driver was newly developed. Moreover, the functions of the driver and data transfer performance of the VME and CAMAC complex system were tested. The test results shown that the VME based microcomputer and CAMAC serial driver can be applied for the fast and reliable acquisition and transfer system for JT-60 control. (author)

  13. Design and quality control of an environmental data acquisition system

    International Nuclear Information System (INIS)

    FANJIRINDRATOVO, T.

    2009-01-01

    The present work is focused on the design of a microcontroller based measurement system and the control quality to validate it. So, a mobile instrument called DALENPA was designed to measure and log the following data: atmospheric pressure, ambient temperature, relative humidity, wind speed and direction, air dose rate, geographical coordinates by an embedded GPS receiver. The instrument is autonomous in energy by solar panel and can be connected to a PC directly or by modem. After, the quality control is based on the calibartion in a secondary laboratory. The target is to get its calibration curve and the estimation of global uncertainties. This estimation wants to include all sources of uncertainty belonging to the instrument and the secondary laboratory, and follows the method estabilished by the International Organization for Standardization (ISO) and the Bureau International des Poids et Mesures (BIPM). The calibration curve is fitted by the least squares method with uncertainties in the two variables. We got an efficient instrument with uncertainties under the limits estabilished by the regulating standards [fr

  14. The Belle II PXD data acquisition and reduction system

    Energy Technology Data Exchange (ETDEWEB)

    Lange, Soeren; Gessler, Thomas; Kuehn, Wolfgang; Muenchow, David; Spruck, Bjoern [Giessen Univ. (Germany). 2. Physikalisches Inst.; Lin, Haichuan; Liu, Zhen-An; Xu, Hao; Zhao, Jingzhou [IHEP Beijing (China); Collaboration: Belle II Collaboration

    2013-07-01

    The Belle II DEPFET pixel detector (PXD) will deliver high data rates of up to 21.6 Gbytes/s for 3% detector occupancy. Data of this high rate must be buffered for 5 seconds, corresponding to the HLT (High Level Trigger) latency, and then a region-of-interest (ROI) filter is applied to reduce the data rate by a factor of ≥10 by charged track extrapolation from other detectors (SVD, CDC). The PXD readout system is based upon ATCA (Advanced Telecommunications Architecture). The 3rd PCB iteration uses a concept with a xTCA carrier board (with a Virtex-4 FX60 FPGA for ATCA backplane routing) and 4 AMC modules (each with a Xilinx Virtex-5 FX70T FPGA). The FPGA firmware implementation comprises a receiver core for the high speed optical links (≤6.25 Gbps), a buffer management with lookup of ≤270.000 pointers/s, DDR2 memory write (native port interface, ≥1.5 Gbytes/s), Gigabit ethernet (UDP stack in VHDL) and a parallelized ROI selection algorithm. Test results of all the components are presented.

  15. Alternate mode for data acquisition and real-time monitoring system based on CAMAC system

    International Nuclear Information System (INIS)

    Luo, J.R.; Wei, P.J.; Li, G.M.; Wang, H.

    2006-01-01

    Long discharges (about 250 s) have been achieved on HT-7 tokamak experiments in the Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). And in the next generation tokamaks like ITER , KSTAR and EAST , the pulses will be about 1000 s. In such steady-state operation, we have to upgrade the CAMAC-based data acquisition system, with higher sampling rates and longer acquisition times. It is necessary to monitor the plasma parameters in real-time so that the operators can change the operational conditions during the discharge to maintain the plasma. A design of the system named alternant data acquisition and real-time monitoring system for steady-state tokamak operation based on CAMAC system has been setup in ASIPP. The application of this system has been demonstrated in the HT-7 and TRIAM-1M tokamaks during their 2004 experiment campaigns

  16. The data acquisition system of the Belle II Pixel Detector

    Science.gov (United States)

    Münchow, D.; Dingfelder, J.; Geßler, T.; Konorov, I.; Kühn, W.; Lange, S.; Lautenbach, K.; Levit, D.; Liu, Z.; Marinas, C.; Schnell, M.; Spruck, B.; Zhao, J.

    2014-08-01

    At the future Belle II experiment the DEPFET (DEPleted Field Effect Transistor) pixel detector will consist of about 8 million channels and is placed as the innermost detector. Because of its small distance to the interaction region and the high luminosity in Belle II, for a trigger rate of about 30 kHz with an estimated occupancy of about 3 % a data rate of about 22 GB/s is expected. Due to the high data rate, a data reduction factor higher than 30 is needed in order to stay inside the specifications of the event builder. The main hardware to reduce the data rate is a xTCA based Compute Node (CN) developed in cooperation between IHEP Beijing and University Giessen. Each node has as main component a Xilinx Virtex-5 FX70T FPGA and is equipped with 2 × 2 GB RAM , GBit Ethernet and 4 × 6.25 Gb/s optical links. An ATCA carrier board is able to hold up to four CN and supplies high bandwidth connections between the four CNs and to the ATCA backplane. To achieve the required data reduction on the CNs, regions of interest (ROI) are used. These regions are calculated in two independent systems by projecting tracks back to the pixel detector. One is the High Level Trigger (HLT) which uses data from the Silicon Vertex Detector (SVD), a silicon strip detector, and outer detectors. The other is the Data Concentrator (DATCON) which calculates ROIs based on SVD data only, in order to get low momentum tracks. With this information, only PXD data inside these ROIs will be forwarded to the event builder, while data outside of these regions will be discarded. First results of the test beam time in January 2014 at DESY with a Belle II vertex detector prototype and full DAQ chain will be presented.

  17. Workshop on data acquisition and trigger system simulations for high energy physics

    International Nuclear Information System (INIS)

    1992-01-01

    This report discusses the following topics: DAQSIM: A data acquisition system simulation tool; Front end and DCC Simulations for the SDC Straw Tube System; Simulation of Non-Blocklng Data Acquisition Architectures; Simulation Studies of the SDC Data Collection Chip; Correlation Studies of the Data Collection Circuit ampersand The Design of a Queue for this Circuit; Fast Data Compression ampersand Transmission from a Silicon Strip Wafer; Simulation of SCI Protocols in Modsim; Visual Design with vVHDL; Stochastic Simulation of Asynchronous Buffers; SDC Trigger Simulations; Trigger Rates, DAQ ampersand Online Processing at the SSC; Planned Enhancements to MODSEM II ampersand SIMOBJECT -- an Overview -- R.; DAGAR -- A synthesis system; Proposed Silicon Compiler for Physics Applications; Timed -- LOTOS in a PROLOG Environment: an Algebraic language for Simulation; Modeling and Simulation of an Event Builder for High Energy Physics Data Acquisition Systems; A Verilog Simulation for the CDF DAQ; Simulation to Design with Verilog; The DZero Data Acquisition System: Model and Measurements; DZero Trigger Level 1.5 Modeling; Strategies Optimizing Data Load in the DZero Triggers; Simulation of the DZero Level 2 Data Acquisition System; A Fast Method for Calculating DZero Level 1 Jet Trigger Properties and Physics Input to DAQ Studies

  18. Workshop on data acquisition and trigger system simulations for high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-12-31

    This report discusses the following topics: DAQSIM: A data acquisition system simulation tool; Front end and DCC Simulations for the SDC Straw Tube System; Simulation of Non-Blocklng Data Acquisition Architectures; Simulation Studies of the SDC Data Collection Chip; Correlation Studies of the Data Collection Circuit & The Design of a Queue for this Circuit; Fast Data Compression & Transmission from a Silicon Strip Wafer; Simulation of SCI Protocols in Modsim; Visual Design with vVHDL; Stochastic Simulation of Asynchronous Buffers; SDC Trigger Simulations; Trigger Rates, DAQ & Online Processing at the SSC; Planned Enhancements to MODSEM II & SIMOBJECT -- an Overview -- R.; DAGAR -- A synthesis system; Proposed Silicon Compiler for Physics Applications; Timed -- LOTOS in a PROLOG Environment: an Algebraic language for Simulation; Modeling and Simulation of an Event Builder for High Energy Physics Data Acquisition Systems; A Verilog Simulation for the CDF DAQ; Simulation to Design with Verilog; The DZero Data Acquisition System: Model and Measurements; DZero Trigger Level 1.5 Modeling; Strategies Optimizing Data Load in the DZero Triggers; Simulation of the DZero Level 2 Data Acquisition System; A Fast Method for Calculating DZero Level 1 Jet Trigger Properties and Physics Input to DAQ Studies.

  19. Low-cost data acquisition systems for photovoltaic system monitoring and usage statistics

    Science.gov (United States)

    Fanourakis, S.; Wang, K.; McCarthy, P.; Jiao, L.

    2017-11-01

    This paper presents the design of a low-cost data acquisition system for monitoring a photovoltaic system’s electrical quantities, battery temperatures, and state of charge of the battery. The electrical quantities are the voltages and currents of the solar panels, the battery, and the system loads. The system uses an Atmega328p microcontroller to acquire data from the photovoltaic system’s charge controller. It also records individual load information using current sensing resistors along with a voltage amplification circuit and an analog to digital converter. The system is used in conjunction with a wall power data acquisition system for the recording of regional power outages. Both data acquisition systems record data in micro SD cards. The data has been successfully acquired from both systems and has been used to monitor the status of the PV system and the local power grid. As more data is gathered it can be used for the maintenance and improvement of the photovoltaic system through analysis of the photovoltaic system’s parameters and usage statistics.

  20. User Manual for the AZ-101 Data Acquisition System (AS-101 DAS)

    Energy Technology Data Exchange (ETDEWEB)

    BRAYTON, D.D.

    2000-02-17

    User manual for the TK AZ-101 Waste Retrieval System Data Acquisition System. The purpose of this document is to describe use of the AZ-101 Data Acquisition System (AZ-101 DAS). The AZ-101 DAS is provided to fulfill the requirements for data collection and monitoring as defined in Letters of Instruction (LOI) from Numatec Hanford Corporation (NHC) to Fluor Federal Services (FFS). For a complete description of the system, including design, please refer to the AZ-101 DAS System Description document, RPP-5572.

  1. User Manual for the AZ-101 Data Acquisition System (AS-101 DAS)

    International Nuclear Information System (INIS)

    BRAYTON, D.D.

    2000-01-01

    User manual for the TK AZ-101 Waste Retrieval System Data Acquisition System. The purpose of this document is to describe use of the AZ-101 Data Acquisition System (AZ-101 DAS). The AZ-101 DAS is provided to fulfill the requirements for data collection and monitoring as defined in Letters of Instruction (LOI) from Numatec Hanford Corporation (NHC) to Fluor Federal Services (FFS). For a complete description of the system, including design, please refer to the AZ-101 DAS System Description document, RPP-5572

  2. A real-time remote sensing and data acquisition system for a nuclear power plant

    International Nuclear Information System (INIS)

    Kim, Ki Ho; Hieu, Bui Van; Beak, Seung Hyun; Choi, Seung Hwan; Son, Tae Ha; Kim, Jung Kuk; Han, Seung Chul

    2011-01-01

    A Structure Health Monitoring (SHM) system needs a real-time remote data acquisition system to monitor the status of a structure from anywhere via Internet access. In this paper, we present a data acquisition system that monitors up to 40 Fiber Bragg Grating Sensors remotely in real-time. Using a TCP/IP protocol, users can access information gathered by the sensors from anywhere. An experiment in laboratory conditions has been done to prove the feasibility of our proposed system, which is built in special-purpose monitoring system

  3. Control and Data Acquisition System for the Spanish Beamline (BM25) at the ESRF

    International Nuclear Information System (INIS)

    Pereira Gonzalez, A.; Olalla Garcia, C.; Sanchez Sanz, J.; Castro, G. R.

    2005-01-01

    A new control and data acquisition system has been developed for BM25 Spanish Line at the ESRF. The system is based in VMEbus, Motorola PreP architecture and Linux Operating System and it's linked to a local ETHERNET network which provides the way of communicate with the servers (PC workstations). In these computers, the data are available for general usage in order to analyze them. The data acquisition consists of many channels connected to the VME crates mainly, independent between them, and fully programmable by drivers, CLUI's and GUI's interfaces, and a set of independent systems (embedded ones, PLCs, others) controlling the security aspects. This report is described in terms of their architecture, their electronic system to the process hard ware and the functionality and the application development facilities they provide using the software and the data acquisition. (Author) 18 refs

  4. A high-speed CAMAC data acquisition system for PDP-11

    International Nuclear Information System (INIS)

    Berg, D.M.; Heinicke, P.; Quigg, L.

    1985-01-01

    This paper describes a high-speed data acquisition system for a PDP-11 running under the RSX-11M operating system. It has been used by several high-energy physics experiments at Fermilab. The system consists of several coordinated tasks which acquire data through a CAMAC interface, log data to magnetic tape, supply data to independent monitoring and analysis tasks (such as RSXMULTI), and perform control functions. A data buffer extending beyond the 18-bit address space of the PDP-11 is implemented using Konelar bank-switchable memory. Supported configurations range from small systems with single data acquisition and analysis tasks on the same processor, to large multi-processor systems with data acquisition on several PDPs and analysis on separate PDPs or VAXs

  5. Data acquisition system for the neutron scattering instruments at the intense pulsed neutron source

    International Nuclear Information System (INIS)

    Crawford, R.K.; Daly, R.T.; Haumann, J.R.; Hitterman, R.L.; Morgan, C.B.; Ostrowski, G.E.; Worlton, T.G.

    1981-01-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a major new user-oriented facility which is now coming on line for basic research in neutron scattering and neutron radiation damage. This paper describes the data-acquisition system which will handle data acquisition and instrument control for the time-of-flight neutron-scattering instruments at IPNS. This discussion covers the scientific and operational requirements for this system, and the system architecture that was chosen to satisfy these requirements. It also provides an overview of the current system implementation including brief descriptions of the hardware and software which have been developed

  6. Development of a Data Acquisition System for the BaBar CP Violation Experiment

    International Nuclear Information System (INIS)

    Claus, Richard

    1999-01-01

    Experiences developing data acquisition system for the BaBar CP violation experiment located at the Stanford Linear Accelerator Center are presented. The BaBar detector consists of multiple independent subdetectors joined with a data acquisition system consisting of a large number of embedded PowerPC single board computers residing in VME crates. The data acquisition software is layered on the VxWorks real-time operating system. It is partitionable to allow subsystems (as well as test stands) to operate independently. Data is assimilated into events through a combination of shared memory and a high performance network. This system presents data to a UNIX farm via a high speed non-blocking ethernet switch at a rate of 2 KHz. Topics such as bootstrapping and loading 200 processors, NFS file access for these processors and software development and deployment are discussed

  7. Development of a Data Acquisition System for the BaBar CP Violation Experiment

    CERN Document Server

    Scott, I; Grosso, P; Hamilton, R T; Huffer, M E; O'Grady, C P; Russell, J J

    1999-01-01

    Experiences developing data acquisition system for the BaBar CP violation experiment located at the Stanford Linear Accelerator Center are presented. The BaBar detector consists of multiple independent subdetectors joined with a data acquisition system consisting of a large number of embedded PowerPC single board computers residing in VME crates. The data acquisition software is layered on the VxWorks real-time operating system. It is partitionable to allow subsystems (as well as test stands) to operate independently. Data is assimilated into events through a combination of shared memory and a high performance network. This system presents data to a UNIX farm via a high speed non-blocking ethernet switch at a rate of 2 KHz. Topics such as bootstrapping and loading 200 processors, NFS file access for these processors and software development and deployment are discussed.

  8. Coil measurement data acquisition and curing press control system for SSC dipole magnet coils

    International Nuclear Information System (INIS)

    Dickey, C.E.

    1989-03-01

    A coil matching program, similar in theory to the methods used to match Tevatron coils, is being developed at Fermilab. Modulus of elasticity and absolute coil size will be determined at 18-inch intervals along the coils while in the coil curing press immediately following the curing process. A data acquisition system is under construction to automatically acquire and manage the large quantities of data that result. Data files will be transferred to Fermilab's VAX Cluster for long-term storage and actual coil matching. The data acquisition system will also provide the control algorithm for the curing press hydraulic system. A description of the SSC Curing Press Data Acquisition and Controls System will be reported. 20 figs

  9. Design and implementation of data acquisition, communication and monitoring system for photovoltaic power station in microgrid

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Wei; Pei, Wei; Qi, Zhiping; Kong, Li [Institute of Electrical Engineering, CAS, Beijing (China)

    2008-07-01

    This paper presents the design and realization of data acquisition, communication and monitoring system for photovoltaic power station. The data acquisition module including filter algorithm and signal modulation circuit uses the digital signal processor (DSP) as the main processor, it can realize accurate real-time data acquisition; The data communication module uses Ethernet as communication network between PV system and MicroGrid. The gateway using ARM microprocessor can realize protocol conversion and bidirectional communication between CAN Bus and Ethernet; The monitoring unit with friendly human-machine interface keeps real-time performance monitoring of PV system to realize automation control. The results of experiment show that the system is practicable and effective. (orig.)

  10. Control and data acquisition system for the macromolecular crystallography beamline of SSRF

    International Nuclear Information System (INIS)

    Wang Qisheng; Huang Sheng; Sun Bo; Tang Lin; He Jianhua

    2012-01-01

    The macromolecular crystallography beamline BL17U1 of Shanghai Synchrotron Radiation Facility (SSRF) is an important platform for structure biological science. High performance of the beamline would benefit the users greatly in their experiment and data acquisition. To take full advantage of the state-of-the-art mechanical and physical design of the beamline, we have made a series of efforts to develop a robust control and data acquisition system, with user-friendly GUI. These were done by adopting EPICS and Blu-Ice systems on the BL17U1 beamline, with considerations on easy accommodation of new beeline components. In this paper, we report the integration of EPICS and Blu-Ice systems. By using the EPICS gateway interface and several new DHS, Blu-Ice was successfully established for the BL17U1 beamline. As a result, the experiment control and data acquisition system is reliable and functional for users. (authors)

  11. System Description for Tank 241-AZ-101 Waste Retrieval Data Acquisition System

    International Nuclear Information System (INIS)

    ROMERO, S.G.

    2000-01-01

    The proposed activity provides the description of the Data Acquisition System for Tank 241-AZ-101. This description is documented in HNF-5572, Tank 241-AZ-101 Waste Retrieval Data Acquisition System (DAS). This activity supports the planned mixer pump tests for Tank 241-AZ-101. Tank 241-AZ-101 has been selected for the first full-scale demonstration of a mixer pump system. The tank currently holds over 960,000 gallons of neutralized current acid waste, including approximately 12.7 inches of settling solids (sludge) at the bottom of the tank. As described in Addendum 4 of the FSAR (LMHC 2000a), two 300 HP mixer pumps with associated measurement and monitoring equipment have been installed in Tank 241-AZ-101. The purpose of the Tank 241-AZ-101 retrieval system Data Acquisition System (DAS) is to provide monitoring and data acquisition of key parameters in order to confirm the effectiveness of the mixer pumps utilized for suspending solids in the tank. The suspension of solids in Tank 241-AZ-101 is necessary for pretreatment of the neutralized current acid waste and eventual disposal as glass via the Hanford Waste Vitrification Plant. HNF-5572 provides a basic description of the Tank 241-AZ-101 retrieval system DAS, including the field instrumentation and application software. The DAS is provided to fulfill requirements for data collection and monitoring. This document is not an operations procedure or is it intended to describe the mixing operation. This USQ screening provides evaluation of HNF-5572 (Revision 1) including the changes as documented on ECN 654001. The changes include (1) add information on historical trending and data backup, (2) modify DAS I/O list in Appendix E to reflect actual conditions in the field, and (3) delete IP address in Appendix F per Lockheed Martin Services, Inc. request

  12. Electrical probe diagnostic with fast data acquisition systems of the Novillo tokamak

    International Nuclear Information System (INIS)

    Lopez-Callejas, R.; Benitez-Read, J.S.; Longoria-Gandara, L.C.; Pacheco-Sotelo, J.O.; Valencia-Alvarado, R.; Tamayo, F.J.; Valdes, A.; Fernandez, M.C.; Serrano, F.

    2001-01-01

    This paper describes the electrical probe diagnostic system used to measure the relevant parameters of the plasma column generated in the Novillo tokamak, and an inexpensive and fast data acquisition system that consists of 16 independent channels, 8 bit resolution, sampling frequency of 500 kHz, and 8 kword memory per channel. A distributed, modular and transparent approach was used for designing the software-operated data acquisition, diagnostic, and capacitor banks triggering systems, satisfying the pulsed nature of the tokamak discharge. Through a personal computer, the experimental data are available to engineers and physicists in a centralized database

  13. Low Power system Design techniques for mobile computers

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Smit, Gerardus Johannes Maria

    1997-01-01

    Portable products are being used increasingly. Because these systems are battery powered, reducing power consumption is vital. In this report we give the properties of low power design and techniques to exploit them on the architecture of the system. We focus on: min imizing capacitance, avoiding

  14. A large channel count multi client data acquisition system for superconducting magnet system of SST-1

    International Nuclear Information System (INIS)

    Doshi, K.; Pradhan, S.; Masand, H.; Khristi, Y.; Dhongde, J.; Sharma, A.; Parghi, B.; Varmora, P.; Prasad, U.; Patel, D.

    2012-01-01

    The magnet system of the Steady-state Superconducting Tokamak-1 at the Institute for Plasma Research, Gandhinagar, India, consists of sixteen Toroidal field and nine Poloidal field Superconducting coils together with a pair of resistive PF coils, an air core ohmic transformer and a pair of vertical field coils. These coils are instrumented with various cryogenic grade sensors and voltage taps to monitor its operating status and health during different operational scenarios. A VME based data acquisition system with remote system architecture is implemented for data acquisition and control of the complete magnet operation. Client-Server based architecture is implemented with remote hardware configuration and continuous online/offline monitoring. A JAVA based platform independent client application is developed for data analysis and data plotting. The server has multiple data pipeline architecture to send data to storage database, online plotting application, numerical display screen, and run time calculation. This paper describes software architecture, design and implementation of the data acquisition system. (author)

  15. A new kind of data acquisition control system with multi-functions

    International Nuclear Information System (INIS)

    Zhang Songshou; Li Shuyuan; Li Runxin; Guo Dunjun

    1996-01-01

    The paper introduces a new kind of data acquisition control system with multi-functions. The system uses the single-chip microcomputer and the standard STD system. The text recounts its functions, principal, constitution, software and hardware designs, experiment outcome and the conclusions

  16. A general purpose program system for high energy physics experiment data acquisition and analysis

    International Nuclear Information System (INIS)

    Li Shuren; Xing Yuguo; Jin Bingnian

    1985-01-01

    This paper introduced the functions, structure and system generation of a general purpose program system (Fermilab MULTI) for high energy physics experiment data acquisition and analysis. Works concerning the reconstruction of MULTI system level 0.5 which can be run on the computer PDP-11/23 are also introduced briefly

  17. The TC13 tape coupler and its application in data acquisition system

    International Nuclear Information System (INIS)

    Duan Hongwe; Yin Xijing; Ge Yuanxiu

    1993-01-01

    MODAS II is based on PDP-11 and all-assemble-language data acquisition system. It uses the DMA data transfer means and hardware zero-eliminating. However, its tape system TM11 is slow. We replace it with TC13 and reprogram the driver programme to improve the efficiency of the system

  18. Revitalisation of Control and Data Acquisition Systems for Corrosion Test Loop

    International Nuclear Information System (INIS)

    Khairul Handono; Kiswanta; Edy Sumarno

    2008-01-01

    The replacement of control and data acquisition systems for Corrosion Test Loop (CTL) has been conducted. The aim of revitalisation for CTL is to increase controller system performance Kent 4000 which is based on PLC. On the other side revitalisation of acquisition data system is done to build computer based data retrieval system for transformation gauging of parameters in thermalhydraulic experiment of CTL. Previously, data collector system used indicator recorder analog, while data recording is done manually, which caused causing very slow response and the result is less accurate. To increase the user quality of data collector system, the data acquisition system is developed with application program Visual Basic and acquisition apparatus card of data. Result of the activity of revitalisation CTL is to obtain of control systems based on PLC and data acquisition system capable to present information in the form of temperature, pressure and cooling water level interactively, namely easy to read, quickly, realtime and accurate. This results give the improvement of control systems performance and data acquisition system which data storage of acquisition into hard disk in the form of file and further processed in the form of tables or graph to facilitate the analysis. (author)

  19. The data acquisition system used in one-dimension multichannel fast electron energy loss spectrometer

    International Nuclear Information System (INIS)

    Jiang Weichun; Zhu Linfan; Zhang Yijun; Xu Kezuo

    2010-01-01

    It describes a data acquisition system used in one dimension multichannel fast electron energy loss spectrometer, which can work in scan acquisition mode and static acquisition mode. The timing precision of the scan mode is less than 4 μs by utilizing the gated signal generated by data acquisition card DAQ2010 and an AND logic circuit. A timer card PCI8554 is used to synchronize the data acquisition card and the personal computer. The scan voltage supply is controlled by the personal computer through the RS232 interface. The multithreading technology is used in the acquisition software in order to improve the accommodating-err ability of the acquisition system. A satisfactory test result is given. (authors)

  20. Data acquisition and command system for use with a microprocessor-based control chassis

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.; Martinez, V.A. Jr.

    1980-01-01

    The Pion Generation for Medical Irradiations (PIGMI) program at the Los Alamos Scientific Laboratory is developing the technology to build smaller, less expensive, and more reliable proton linear accelerators for medical applications, and has designed a powerful, simple, inexpensive, and reliable control and data acquisition system that is central to the program development. The system is a NOVA-3D minicomputer interfaced to several outlying microprocessor-based controllers, which accomplish control and data acquisition through data I/O chasis. The equipment interface chassis, which can issue binary commands, read binary data, issue analog commands, and read timed and untimed analog data is described

  1. Data-acquisition system of the reversed field pinch device REPUTE-1

    International Nuclear Information System (INIS)

    Tsuzuki, N.; Aoki, H.; Shinohara, H.; Toyama, H.; Morikawa, J.

    1988-01-01

    The new, compact data-acquisition system of the reversed field pinch device, REPUTE-1, is reported. Its distinctive feature is high flexibility and easy handling. The interface between the computer and measurement devices is CAMAC. The computer and the CAMAC devices are connected to a CAMAC byte serial highway that transmits setup parameters and acquisition data. The computer carries out setup of CAMAC devices and data acquisition automatically by use of CAMAC parameters and the acquisition data base. The maintenance tools for the data base are also provided. The computer system, which consists of a ''TOSBAC DS-600,'' has been in operation for REPUTE-1 since 1985

  2. Multiparameter data acquisition and analysis system for capture gamma-ray studies

    International Nuclear Information System (INIS)

    Hejja, I.; Belgya, T.; Molnar, G.L.; Szepesvary, A.

    1997-01-01

    A PC-based multiparameter data acquisition system has been built for the Budapest neutron capture gamma-ray spectrometer. The hardware consists of a homemade multiplexer accommodating up to ten ADC inputs, a 64 kword histogram memory board and a National Instruments 32-bit DIO card, used for data acquisition and control, as well as a timer/scaler TIO card of the same company. The multiplexer inputs can be flexibly configured by means of programmable XILINX logic chips. The system is driven by a Pentium PC connected to the local Ethernet. (author)

  3. An adaptive structure data acquisition system using a graphical-based programming language

    Science.gov (United States)

    Baroth, Edmund C.; Clark, Douglas J.; Losey, Robert W.

    1992-01-01

    An example of the implementation of data fusion using a PC and a graphical programming language is discussed. A schematic of the data acquisition system and user interface panel for an adaptive structure test are presented. The computer programs (a series of icons 'wired' together) are also discussed. The way in which using graphical-based programming software to control a data acquisition system can simplify analysis of data, promote multidisciplinary interaction, and provide users a more visual key to understanding their data are shown.

  4. Sensors of a Beechcraft C90 Aircraft for Extension of Data Acquisition System

    Directory of Open Access Journals (Sweden)

    Elena BALMUS

    2017-03-01

    Full Text Available In-flight data acquisition is a key point in the aircraft design process. For the control of a simulated prototype using the control surfaces, state variables such as acceleration, pitch rate for longitudinal motion, and roll rate or slideslip angle for lateral-directional motion are commonly defined as control variables. The purpose of this paper is to evaluate the risk of in -flight laboratory modification through extension of data acquisition system for collection of additional data related to pilot command input and the reaction of the system.

  5. Design of Real Time Data Acquisition System Framework for Production Workshop Based on OPC Technology

    Directory of Open Access Journals (Sweden)

    Yue-xin Yang

    2017-01-01

    Full Text Available In this paper, the low level of production management information in a hydraulic torque converter enterprise is presented. It is needed to develop a digital assembly shop MES to solve this problem. There is a high demand for the real-time data acquisition of the production line in the digital assembly shop MES. According to the actual needs of MES in digital assembly workshop, a real time data acquisition system framework based on OPC technology and database technology is proposed. The framework can be used to meet the actual needs of the real time monitoring system and production business information processing in MES.

  6. Development of data acquisition system for tracing fast flow using GPIB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications.

  7. Development of data acquisition system for tracing fast flow using GPIB

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee

    2003-12-01

    Radiotracer data acquisition system which was developed by radiotracer group in Korea Atomic Energy Research Institute has been used for field experiment since the late of 1990s. It has RS232C and 24 channel x10 sample. It was useful for radiotracer experiment whose period span from few second to few ten days. But the demand for tracing fast flow has been increasing. For example, to trace a fast gas flow in petro chemical industry or for application like computer aided radioactive particle tracking, high speed data acquisition system is necessary. The current commercial data acquisition systems have limited count channels. To solve above mentioned problem upgraded high speed data acquisition system using GPIB is developed. GPIB system is one method of control and communication. The data transmit speed of GPIB is 200k byte/sec which is faster then 20k bps of RS232C. In addition to that, GPIB has advantage of expanding up to 15 devices. It mean that 24 x15 channel is possible if one device has 24channel. It make possible to trace high fast flow or large number of channel. This technical report include details of the design of high speed multi-channel radiation detecting system which is consist of ratemeter module, display unit, mainboard with GPIB system and 24 channel counter board. The design of GPIB system developed here is also applicable to other measurement system for various applications

  8. Control and data acquisition system for versatile experiment spherical torus at SNU

    Energy Technology Data Exchange (ETDEWEB)

    An, YoungHwa [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Na, DongHyeon; Hwang, Y.S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2013-10-15

    A control and data acquisition system for VEST (Versatile Experiment Spherical Torus) at Seoul National University (SNU) has been developed to enable remote operation from a central control room. The control and data acquisition system consists of three subsystems; a main control and data acquisition system that triggers each device at the preprogrammed timing and collects various diagnostic signals during discharges, a monitoring system that watches and logs the device status continuously, and a data storage and distribution system that stores collected data and provides data access layer via Ethernet. The system is designed to be cost-effective, extensible and easy to develop by using well-established standard technologies and solutions. Combining broad accessibility with modern information technology, alarm signal can be sent immediately to the registered cell phones when the abnormal status of devices is found, and the web data distribution system enables data access from almost everywhere using smart phones or tablet computers. Since December 2011, VEST is operational and the control and data acquisition system has been successfully used for remote operation of VEST.

  9. New software of the control and data acquisition system for the Nuclotron internal target station

    International Nuclear Information System (INIS)

    Isupov, A.Yu.

    2012-01-01

    The control and data acquisition system for the Internal Target Station (ITS) of the Nuclotron (LHEP, JINR) is implemented. The new software is based on the ngdp framework under the Unix-like operating system FreeBSD to allow easy network distribution of the on-line data collected from ITS, as well as the internal target remote control

  10. Merger of the DIAMANT Light Charge Particle Detector into the AFRODITE Data Acquisition System

    International Nuclear Information System (INIS)

    Murray, S.H.T.; Mullins, S.M.; Bark, R.A.; Gueorguieva, E.; Lawrie, J.J.; Pilcher, J.V.; Sharpey-Schafer, J.F.; Gal, J.; Kalinka, G.; Krasznahorkay, A.; Molnar, L.; Nyako, B. M.; Timar, J.; Zolnai, L.; Hlatshwayo, T.; Juhasz, K.; Komati, F.S.; Malwela, T.; Ntshangase, S.; Shirinda, O.

    2005-01-01

    The Chessboard section of the DIAMANT CsI detector array has been merged into the AFRODITE γ-ray spectrometer acquisition system. The details of the data acquisition merging is explained together with how consistency is maintained and ensured between the two distinct systems

  11. A prototype fully digital data acquisition system upgrade for the TOFOR neutron spectrometer at JET

    Energy Technology Data Exchange (ETDEWEB)

    Skiba, Mateusz, E-mail: mateusz.skiba@physics.uu.se [Department of Physics and Astronomy, Uppsala University (Sweden); Ericsson, Göran; Hjalmarsson, Anders; Hellesen, Carl; Conroy, Sean; Andersson-Sundén, Erik; Eriksson, Jacob [Department of Physics and Astronomy, Uppsala University (Sweden); JET Contributors [EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2016-10-11

    A prototype of a fully digital data acquisition system upgrade for the TOFOR time-of-flight fusion neutron spectrometer at JET has been implemented and evaluated. The core of the system is composed of five fast PXIe waveform digitisers (1 GSPS, 12 bits) with large internal fast memory (1 GB). Due to the complexity and high requirements on timing precision of the spectrometer, the design and implementation of such a system poses numerous technical challenges, in particular regarding time alignment and synchronisation of signal paths and digitiser modules. These issues and their solutions, as pertaining to the TOFOR spectrometer, are presented in detail in the present paper. As a final assessment of the ability of the new data acquisition system to reproduce the capabilities of the original TOFOR system, a thorough comparison of results produced using both systems is presented. The comparison with TOFOR has been performed with satisfying results. Two immediate advantages of the new data acquisition system are significantly improved triggering dead time (from about 70 ns to 10 ns) and the ability to adjust the triggering thresholds as needed during the analysis step. The enhanced spectroscopic capabilities of the new data acquisition system will be reported on in future publications.

  12. Control and data acquisition system for versatile experiment spherical torus at SNU

    International Nuclear Information System (INIS)

    An, YoungHwa; Chung, Kyoung-Jae; Na, DongHyeon; Hwang, Y.S.

    2013-01-01

    A control and data acquisition system for VEST (Versatile Experiment Spherical Torus) at Seoul National University (SNU) has been developed to enable remote operation from a central control room. The control and data acquisition system consists of three subsystems; a main control and data acquisition system that triggers each device at the preprogrammed timing and collects various diagnostic signals during discharges, a monitoring system that watches and logs the device status continuously, and a data storage and distribution system that stores collected data and provides data access layer via Ethernet. The system is designed to be cost-effective, extensible and easy to develop by using well-established standard technologies and solutions. Combining broad accessibility with modern information technology, alarm signal can be sent immediately to the registered cell phones when the abnormal status of devices is found, and the web data distribution system enables data access from almost everywhere using smart phones or tablet computers. Since December 2011, VEST is operational and the control and data acquisition system has been successfully used for remote operation of VEST

  13. A multi-channel data acquisition system with high resolution based on microcomputer

    International Nuclear Information System (INIS)

    An Qi; Wang Yanfang; Xing Tao

    1995-01-01

    The paper introduces the principle of a multi-channel data acquisition system with high resolution based on the microcomputer.The system consists of five parts.They are analog-to-digital converter, data buffer area, trigger logic circuit, control circuit, and digital-to-analog converter

  14. The hardware and software design for digital data acquisition system of γ-camera

    International Nuclear Information System (INIS)

    Zhang Chong; Jin Yongjie

    2006-01-01

    The digital data acquisition system is presented, which are used to update the traditional γ-cameras, including hardware and software. The system has many advantages such as small volume, various functions, high-quality image, low cost, extensible, and so on. (authors)

  15. 241-SY-101 data acquisition and control system (DACS) operator interface upgrade operational test report

    International Nuclear Information System (INIS)

    ERMI, A.M.

    1999-01-01

    This procedure provides instructions for readiness of the first portion of the upgraded 241-SY-101 Data Acquisition and Control System (DACS) computer system to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank will be systematically evaluated by the performance of this procedure

  16. FASTBUS based data acquisition system for the DI-lepton spectrometer at the BEVALAC

    International Nuclear Information System (INIS)

    Matis, H.S.; Claesson, G.; Hendrie, D.

    1985-10-01

    A data acquisition system using FASTBUS has been developed. FASTBUS TDC's are used to record hits from a drift chamber, while FASTBUS ADC's digitize the pulse heights from the chambers. FASTBUS data are transferred to CAMAC and then written to a VAX 11/750 using a MBD. The performance of this system is discussed. 5 refs., 4 figs

  17. Microprocessor system for data acquisition processing and display for Auger electrons spectrometer

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Cudny, W.; Hildebrandt, S.; Marzec, J.; Walentek, J.; Zaremba, K.

    1984-01-01

    Data acquisition system for Auger electron spectrometry is developed. The system is used for chemical and structural analysis of materials and consists of a cylindrical mirror analyzer being a measuring spectrometer device, CAMAC unit and control unit. The control unit comprises a microcomputer based on INTEL 8080 microprocessor and display

  18. High-speed multiple-channel analog to digital data-acquisition module for microprocessor systems

    International Nuclear Information System (INIS)

    Ethridge, C.D.

    1977-01-01

    Intelligent data acquisition and instrumentation systems established by the incorporation of microprocessor technology require high-speed analog to digital conversion of multiple-channel input signals. Sophisticated data systems or subsystems are enabled by the microprocessor software flexibility to establish adaptive input data procedures. These adaptive procedures are enhanced by versatile interface circuitry which is software controlled

  19. EWLMII: a measurement and data-acquisition system for radon daughters

    Energy Technology Data Exchange (ETDEWEB)

    Keefe, D.J.; McDowell, W.P.; Groer, P.G.

    1981-01-01

    Development of new methods and instruments for the measurement of WL and Rn-daughter concentrations has been in progress for several years. However, efficient methods of data acquisition has not been the primary thrust of this research. If large volumes of data from automated instruments are to be efficiently analyzed, a built in data acquisition system is needed. One such instrument, the EWLMII, is described. The need for accelerated research for the understanding and control of Rn-daughters can be enhanced by such an instrument.

  20. EWLMII: a measurement and data-acquisition system for radon daughters

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Groer, P.G.

    1981-01-01

    Development of new methods and instruments for the measurement of WL and Rn-daughter concentrations has been in progress for several years. However, efficient methods of data acquisition has not been the primary thrust of this research. If large volumes of data from automated instruments are to be efficiently analyzed, a built in data acquisition system is needed. One such instrument, the EWLMII, is described. The need for accelerated research for the understanding and control of Rn-daughters can be enhanced by such an instrument

  1. Computer-controlled data acquisition system for the ISX-B neutral injection system

    International Nuclear Information System (INIS)

    Edmonds, P.H.; Sherrill, B.; Pearce, J.W.

    1980-05-01

    A data acquisition system for the Impurity Study Experiment (ISX-B) neutral injection system at the Oak Ridge National Laboratory is presented. The system is based on CAMAC standards and is controlled by a MIK-11/2 microcomputer. The system operates at the ion source high voltage on the source table, transmitting the analyzed data to a terminal at ground potential. This reduces the complexity of the communications link and also allows much flexibility in the diagnostics and eventual control of the beam line

  2. Report on best practice for micro/nano replication process data acquisition systems

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    The main objective of this deliverable is to collect detailed description on the best practice for micro/ nano replication process data acquisition system. In particular the following aspects are summed up in the deliverable: Process requirements for COTECH demonstrators General description of th....... This report presents the important processes and process parameters required for the realization of COTECH demonstrator. It also presents the cutting edge sensor systems used for different process and set a guideline to integrate sensors in COTECH tools.......The main objective of this deliverable is to collect detailed description on the best practice for micro/ nano replication process data acquisition system. In particular the following aspects are summed up in the deliverable: Process requirements for COTECH demonstrators General description...... of the processes and process parameters State-of-the-art process control and data acquisition systems Sensor integration in COTECH tools Expected COTECH improvement in process control and data acquisition system Information provide by this deliverable will be used as input to the COTECH process control system...

  3. WiFi Data Acquisition System Applied to a Photovoltaic Powered Water Pumping Plant

    Directory of Open Access Journals (Sweden)

    Sandro César Silveira JUCÁ

    2015-02-01

    Full Text Available The present paper describes how to design and assemble a low cost online monitoring and WiFi data acquisition system using free software applied to microgeneration based on renewable energy sources. The development of online monitoring systems for microgeneration plants based on renewable energy sources is becoming more important, considering that monitoring and data acquisition systems are applicable in stages of the microgeneration process. The monitoring and data acquisition WiFi system was developed using an embedded WiFi modem (Wifly coupled to a microcontrolled board based on the free tool SanUSB. This monitoring system was applied to a photovoltaic (PV water pumping plant without batteries, so as the control system and the wireless communication with the online server, which is also autonomous and powered by PV panel. The free software for online monitoring and WiFi data acquisition allows the analysis of stored data and charts through mobile devices as notebooks, tablets and smartphones.

  4. Continuous and real-time data acquisition system for superconducting tokamaks HT-7 and TRIAM-1M

    International Nuclear Information System (INIS)

    Wang, F.; Luo, J.R.; Nakamura, K.; Sato, K.N.; Hanada, K.; Sakamoto, M.; Idei, H.; Kawasaki, S.; Nakashima, H.

    2006-01-01

    Conventional data acquisition systems cannot deal with data acquisition for a long-time discharge of a nuclear fusion reactor. Thus, continuous data acquisition with a real-time data presentation during discharge must be developed. Two data acquisition systems, which include alternating CAMAC data acquisition and long-time PCI data acquisition, are designed for the long-time operation of HT-7 tokamak. Since an effective alternating mode is adopted, the alternating CAMAC data acquisition can accurately and continuously acquire data at a rate of 10 kHz. The acquired data is immediately transmitted to a data server and real-time results can be presented during the plasma discharge. As for the long-time PCI data acquisition, a special kind of PCI A/D card, which has a hard disk on board, is designed to collect data at a max speed of 200 kHz. Thus, the total sampling duration is only related to the capacity of the hard disk on board. These two types of data acquisitions were applied to HT-7 tokamak and a 250 s discharge was acquired. These data acquisition systems were also successfully demonstrated on a 2500 s plasma discharge on TRIAM-1M. This paper describes the two data acquisitions in detail

  5. Development of remote data acquisition system based on OPC for brake test bench

    Science.gov (United States)

    Wang, Yiwei; Wu, Mengling; Tian, Chun; Ma, Tianhe

    2017-08-01

    The 1:1 train brake system test bench can be used to carry out brake-related adhesion-slid control, stability test, noise test and dynamic test. To collect data of the test bench, a data acquisition method is needed. In this paper, the remote data acquisition system of test bench is built by LabVIEW based on OPC technology. Unlike the traditional hardwire way connecting PLC acquisition module with sensors, the novel method is used to collect data and share them through the internal LAN built by Ethernet switches, which avoids the complex wiring interference in an easy, efficient and flexible way. The system has been successfully applied to the data acquisition activities of the comprehensive brake system test bench of CRRC Nanjing Puzhen Haitai Brake Equipment Co., Ltd., and the relationship test between the adhesion coefficient and the slip-ratio is realized. The speed signal, torque signal and brake disc temperature can be collected and displayed. The results show that the system is reliable, convenient, and efficient, and can meet the requirements of data acquisition.

  6. Estimate of pulse-sequence data acquisition system for multi-dimensional measurement

    International Nuclear Information System (INIS)

    Kitamura, Yasunori; Sakae, Takeji; Nohtomi, Akihiro; Matoba, Masaru; Matsumoto, Yuzuru.

    1996-01-01

    A pulse-sequence data acquisition system has been newly designed and estimated for the measurement of one- or multi-dimensional pulse train coming from radiation detectors. In this system, in order to realize the pulse-sequence data acquisition, the arrival time of each pulse is recorded to a memory of a personal computer (PC). For the multi-dimensional data acquisition with several input channels, each arrival-time data is tagged with a 'flag' which indicates the input channel of arriving pulse. Counting losses due to the existence of processing time of the PC are expected to be reduced by using a First-In-First-Out (FIFO) memory unit. In order to verify this system, a computer simulation was performed, Various sets of random pulse trains with different mean pulse rate (1-600 kcps) were generated by using Monte Carlo simulation technique. Those pulse trains were dealt with another code which simulates the newly-designed data acquisition system including a FIFO memory unit; the memory size was assumed to be 0-100 words. And the recorded pulse trains on the PC with the various FIFO memory sizes have been observed. From the result of the simulation, it appears that the system with 3 words FIFO memory unit works successfully up to the pulse rate of 10 kcps without any severe counting losses. (author)

  7. Estimate of pulse-sequence data acquisition system for multi-dimensional measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Yasunori; Sakae, Takeji; Nohtomi, Akihiro; Matoba, Masaru [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Matsumoto, Yuzuru

    1996-07-01

    A pulse-sequence data acquisition system has been newly designed and estimated for the measurement of one- or multi-dimensional pulse train coming from radiation detectors. In this system, in order to realize the pulse-sequence data acquisition, the arrival time of each pulse is recorded to a memory of a personal computer (PC). For the multi-dimensional data acquisition with several input channels, each arrival-time data is tagged with a `flag` which indicates the input channel of arriving pulse. Counting losses due to the existence of processing time of the PC are expected to be reduced by using a First-In-First-Out (FIFO) memory unit. In order to verify this system, a computer simulation was performed, Various sets of random pulse trains with different mean pulse rate (1-600 kcps) were generated by using Monte Carlo simulation technique. Those pulse trains were dealt with another code which simulates the newly-designed data acquisition system including a FIFO memory unit; the memory size was assumed to be 0-100 words. And the recorded pulse trains on the PC with the various FIFO memory sizes have been observed. From the result of the simulation, it appears that the system with 3 words FIFO memory unit works successfully up to the pulse rate of 10 kcps without any severe counting losses. (author)

  8. Design of Tokamak synchronous data acquisition system based on PXI express

    International Nuclear Information System (INIS)

    Liu Rui; Zheng Wei; Zhang Ming; Weng Chuqiao; Zhuang Ge; Ding Tonghai; Yu Kexun

    2014-01-01

    With the development of J-TEXT device, the original data acquisition system can't meet the experiment's requirement on stability, modularity and sampling rate, so a new data acquisition system needs to be built. This paper introduces the design and implementation of the distributed Tokamak synchronous high-speed data acquisition system based on PXI Express. The acquisition unit consists of PXIe case Nl PXIe 1062Q, PXIe controller NI PXIe-8133 and high-speed synchronous data acquisition card Nl PXIe-6368, compatible with the latest standard of ITER CODAC, so it has good mechanical sealing, strong modularity and high sampling rate etc. The system takes a synchronous difference acquisition for diagnosis signal. The data storage adopts MDSplus which is the general database in the nuclear fusion field. The test and experimental results show that the system can work continuously and stably at 2 MSps sampling rate, and meet the requirement of experiment device's operation well. (authors)

  9. Construction of a FASTBUS data-acquisition system for the ELAN experiment

    International Nuclear Information System (INIS)

    Noel, A.

    1992-06-01

    To use the FASTBUS data acquisition system for the experiment ELAN at the electron stretcher accelerator ELSA a new software tool has been developed. This tool manages to readout parallel CAMAC with a VME front-end-processor and FASTBUS with the special FASTBUS processor segment AEB. Both processors are connected by a 32 bit high speed VSB data bus. (orig.) [de

  10. Upgrading a TEXTOR Data acquisition system for remote participation using Java and Corba

    NARCIS (Netherlands)

    Korten, M.; Becks, B.; Blom, H.; Busch, P.; Kemmerling, G.; Kooijman, W.; Krom, J. G.; de Laat, C. T. A. M.; Lourens, W.; van der Meer, E.; Niderost, B.; Oomens, A. A. M.; Wijnoltz, F.; Samm, U.

    2000-01-01

    The partners in the Trilateral Euregio Cluster (TEC) are implementing and developing Remote Participation technologies that are expected to support a joint research programme on the experimental facility TEXTOR-94. A common TEC architecture for our heterogeneous data acquisition and storage systems

  11. MDAS2: A Data Acquisition System for the Soil Mechanic Laboratory

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J. M.

    2000-01-01

    The Soil Mechanic Laboratory in CIEMAT is working to characterize a bentonite which may be use in the storage of radioactive waste. The bentonite is studied with several tests, frequently used in soil mechanics. This document describes the data acquisition system used in one of these experiments

  12. Automatic data acquisition system of environmental radiation monitor with a personal computer

    International Nuclear Information System (INIS)

    Ohkubo, Tohru; Nakamura, Takashi.

    1984-05-01

    The automatic data acquisition system of environmental radiation monitor was developed in a low price by using a PET personal computer. The count pulses from eight monitors settled at four site boundaries were transmitted to a radiation control room by a signal transmission device and analyzed by the computer via 12 channel scaler and PET-CAMAC Interface for graphic display and printing. (author)

  13. Design of microprocessor data acquisition system for pedestrian portal SNM monitor

    International Nuclear Information System (INIS)

    Zhang Wenliang

    2003-01-01

    The paper introduces the hardware structure and composition of data acquisition system for pedestrian portal special nuclear material (SNM) monitor. The hardware and software of single chip microprocessor AT89C52, LCM, keyboard and serial communication interface software are also discussed. (authors)

  14. Data acquisition system for Experiment E866 at the Brookhaven AGS

    International Nuclear Information System (INIS)

    Ashktorab, K.; LeVine, M.J.; Scheetz, R.A.

    1993-01-01

    Experiment E866 consists of two spectrometers and related detectors for investigations of collisions of relativistic beams of Au ions with fixed targets at the Brookhaven AGS. The data acquisition system, consisting of 11 CPUs in a single VME crate, gathers data from 8 Camac crates and 6 Fastbus crates

  15. A simple low cost speed log interface for oceanographic data acquisition system

    Digital Repository Service at National Institute of Oceanography (India)

    Khedekar, V.D.; Phadte, G.M.

    A speed log interface is designed with parallel Binary Coded Decimal output. This design was mainly required for the oceanographic data acquisition system as an interface between the speed log and the computer. However, this can also be used as a...

  16. Submicronic Particle Measurement Instrumentation Test Bench Data Acquisition and Control System

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J. M.; Sanz, D.; Gomez, F. J.; Molinero, A.; Navarrete, J. J.

    1999-01-01

    This document describes the SAD-100 system characteristics. The unit makes the instrumentation test bench data acquisition and control, SAD-100 was designed and developed by Electronic and Automation Area (CIEMAT) and Aerosol Technology in Energy Generation Project (CIEMAT). (Author) 2 refs

  17. Duel frequency echo data acquisition system for sea-floor classification

    Digital Repository Service at National Institute of Oceanography (India)

    Navelkar, G.S.; Desai, R.G.P.; Chakraborty, B.

    An echo data acquisition system is designed to digitize echo signal from a single beam shipboard echo-sounder for use in sea-floor classification studies using a 12 bit analog to digital (A/D) card with a maximum sampling frequency of 1 MHz. Both 33...

  18. 241-SY-101 data acquisition and control system (DACS) remote operator interface operational test report

    International Nuclear Information System (INIS)

    ERMI, A.M.

    1999-01-01

    The readiness of the upgraded 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mixer pump and instrumentation in tank 241-SY-101 was evaluated by the performance of OTP-440-001. Results of the OTP are reported here

  19. CONTROL: the run control program used on the WA62 VAX data acquisition system at CERN

    International Nuclear Information System (INIS)

    Hand, R.P.

    1980-11-01

    The criteria are described which have been used in the design of CONTROL, a program in the WA62 VAX Native mode data acquisition system which serves the triple purpose of driving a status display, an operator's console and a message reporter. (U.K.)

  20. System of automatic control over data Acquisition and Transmission to IGR NNC RK Data Center

    International Nuclear Information System (INIS)

    Komarov, I.I.; Gordienko, D.D.; Kunakov, A.V.

    2005-01-01

    Automated system for seismic and acoustic data acquisition and transmission in real time was established in Data Center IGR NNC RK, which functions very successively. The system monitors quality and volume of acquired information and also controls the status of the system and communication channels. Statistical data on system operation are accumulated in created database. Information on system status is reflected on the Center Web page. (author)

  1. System control and data acquisition of the two new FWCD RF systems at DIII-D

    International Nuclear Information System (INIS)

    Harris, T.E.; Allen, J.C.; Cary, W.P. Petty, C.C.

    1995-10-01

    The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The control of the transmitters utilizes VXI technology to communicate with the transmitter's digital interface. A GPIB network allows for communication with various instruments and CAMAC crate controllers. CAMAC crates are located at each phase-shifter/stub-tuner station and are used to digitize transmission line parameters along with transmission line fault detection during RF transmission. The phase-shifter/stub-tuner stations are located through out the DIII-D facility and are controlled from the FWCD operator console via the workstation's Serial port. The Sun workstation has an Ethernet connection allowing for the utilization of the DIII-D data acquisition open-quotes Open Systemclose quotes architecture and of course providing communication with the rest of the world

  2. An Electronic System for Ultra-low Power Hearing Implants

    Science.gov (United States)

    2013-02-15

    Battery Charger Circuit ," IEEE Transactions on Biomedical Circuits and Systems, Vol. 5, No.2, pp. 131-137,2011. [6] K. H. Wee, L. Turicchia, and R...analyzers [1], [2], useful in several hearing systems. 4) We have designed and built a lithium-ion battery -recharging circuit that exploits a novel analog...lab and the use of intelligent low-power filters and circuits have been successful in reducing noise exposure while improving speech intelligibility

  3. A low cost wireless data acquisition system for a remote photovoltaic (PV) water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Mahjoubi, A.; Mechlouch, R. F.; Brahim, A. B. [National School of Engineering of Gabes, Gabes University, Chemical and Processes Engineering Department, Gabes (Tunisia)

    2011-07-01

    This paper presents the design and development of a 16F877 microcontroller-based wireless data acquisition system and a study of the feasibility of different existing methodologies linked to field data acquisition from remote photovoltaic (PV) water pumping systems. Various existing data transmission techniques were studied, especially satellite, radio, Global System for Mobile Communication (GSM) and General Packet Radio Service (GPRS). The system's hardware and software and an application to test its performance are described. The system will be used for reading, storing and analyzing information from several PV water pumping stations situated in remote areas in the arid region of the south of Tunisia. The remote communications are based on the GSM network and, in particular, on the Short text Message Service (SMS). With this integrated system, we can compile a complete database of the different parameters related to the PV water pumping systems of Tunisia. This data could be made available to interested parties over the Internet. (authors)

  4. A PC-Linux-based data acquisition system for the STAR TOFp detector

    International Nuclear Information System (INIS)

    Liu Zhixu; Liu Feng; Zhang Bingyun

    2003-01-01

    Commodity hardware running the open source operating system Linux is playing various important roles in the field of high energy physics. This paper describes the PC-Linux-based Data Acquisition System of STAR TOFp detector. It is based on the conventional solutions with front-end electronics made of NIM and CAMAC modules controlled by a PC running Linux. The system had been commissioned into the STAR DAQ system, and worked successfully in the second year of STAR physics runs

  5. A CAMAC-VME-Macintosh data acquisition system for nuclear experiments

    Science.gov (United States)

    Anzalone, A.; Giustolisi, F.

    1989-10-01

    A multiprocessor system for data acquisition and analysis in low-energy nuclear physics has been realized. The system is built around CAMAC, the VMEbus, and the Macintosh PC. Multiprocessor software has been developed, using RTF, MACsys, and CERN cross-software. The execution of several programs that run on several VME CPUs and on an external PC is coordinated by a mailbox protocol. No operating system is used on the VME CPUs. The hardware, software, and system performance are described.

  6. Development of an Integrated Data Acquisition System for a Small Flight Probe

    Science.gov (United States)

    Swanson, Gregory T.; Empey, Daniel M.; Skokova, Kristina A.; Venkatapathy, Ethiraj

    2012-01-01

    In support of the SPRITE concept, an integrated data acquisition system has been developed and fabricated for preliminary testing. The data acquisition system has been designed to condition traditional thermal protection system sensors, store their data to an on-board memory card, and in parallel, telemeter to an external system. In the fall of 2010, this system was integrated into a 14 in. diameter, 45 degree sphere cone probe instrumented with thermal protection system sensors. This system was then tested at the NASA Ames Research Center Aerodynamic Heating Facility's arc jet at approximately 170 W/sq. cm. The first test in December 2010 highlighted hardware design issues that were redesigned and implemented leading to a successful test in February 2011.

  7. A portable data acquisition system on J.I.P.P. T-II ICRF experiment

    International Nuclear Information System (INIS)

    Hidekuma, S.

    1982-03-01

    This system has been developed for the data acquisition in the J.I.P.P. T-II ICRF experiment. It is composed of the LSI-11/2(56KB), a dual floppy disk drive, CAMAC modules, a graphic display and an interface module to the HITAC 10-II system. The operating system is RT-11. This system has functions of the data acquisition through A-D converters (max.32ch), the transfer of the data to the HITAC 10-II system and the preservation of them in its floppy disk. Furthermore, a user can easily develop his application programs with this system. The operating procedures of this system are described. (author)

  8. Changing of the ELAN data acquisition to an integrated system with VME frontend acquisition and VAX work station analysis

    International Nuclear Information System (INIS)

    Foerster, W.

    1991-07-01

    A new data acquisition system for the experiment ELAN at the electron stretcher accelerator ELSA had become necessary due to changes in the experimental setup. The data acquisition and analysis which formerly both were performed by a single computer system are now separately done by a VMEbus-Computer and a VAX-Workstation. Based on the software components MECDAS (Mainz Experiment Control and Data Acquisition System) and GOOSY (GSI Online Offline System) a powerfull tool for data acquisition and analysis has been adapted to the requirements of the ELAN experiment. (orig.) [de

  9. Automatic calibration and signal switching system for the particle beam fusion research data acquisition facility

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, W.B.

    1979-09-01

    This report describes both the hardware and software components of an automatic calibration and signal system (Autocal) for the data acquisition system for the Sandia particle beam fusion research accelerators Hydra, Proto I, and Proto II. The Autocal hardware consists of off-the-shelf commercial equipment. The various hardware components, special modifications and overall system configuration are described. Special software has been developed to support the Autocal hardware. Software operation and maintenance are described.

  10. PRIS-WEDAS. User’s Manual to the Web Enabled Data Acquisition System for PRIS

    International Nuclear Information System (INIS)

    2015-01-01

    The user manual for the Web Enabled Data Acquisition System (WEDAS), a system that supports the Power Reactor Information System (PRIS), provides instructions, guidelines and detailed definitions for each of the data items required for PRIS. The purpose of this manual is to ensure PRIS performance data are collected consistently and that the required quality of data collection is ensured. This PRIS-WEDAS user’s manual replaces reporting instructions published in the IAEA Technical Reports Series No. 428

  11. Evaluating Information Assurance Control Effectiveness on an Air Force Supervisory Control and Data Acquisition (SCADA) System

    Science.gov (United States)

    2011-03-01

    Byres, E. J., Lowe, J. (2004). The Myths and facts behind cyber security risks for industrial control systems . Berlin, Germany: VDE 2004 Congress...ACQUISITION (SCADA) SYSTEM THESIS Jason R. Nielsen, Major, USAF AFIT/GCO/ENG/11-10 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY AIR FORCE...DATA ACQUISITION (SCADA) SYSTEM THESIS Presented to the Faculty Department of Electrical and Computer Engineering Graduate School of

  12. Automatic calibration and signal switching system for the particle beam fusion research data acquisition facility

    International Nuclear Information System (INIS)

    Boyer, W.B.

    1979-09-01

    This report describes both the hardware and software components of an automatic calibration and signal system (Autocal) for the data acquisition system for the Sandia particle beam fusion research accelerators Hydra, Proto I, and Proto II. The Autocal hardware consists of off-the-shelf commercial equipment. The various hardware components, special modifications and overall system configuration are described. Special software has been developed to support the Autocal hardware. Software operation and maintenance are described

  13. The data acquisition and control system for Thomson Scattering on ATF [Advanced Toroidal Facility

    International Nuclear Information System (INIS)

    Stewart, K.A.; Kindsfather, R.R.; Rasmussen, D.A.

    1989-01-01

    The 2-dimensional Thomson Scattering System measuring electron temperatures and densities in the Advanced Toroidal Facility (ATF) is interfaced to a VAX-8700 computer system running in a clustered configuration. Calibration, alignment, and operation of this diagnostic is under computer control. Extensive CAMAC instrumentation is used for timing control, data acquisition, and laser alignment. This paper will discuss the computer hardware and software, system operations, and data storage and retrieval. 3 refs

  14. Research of Data Acquisition and Analysis System for Internal Combustion Engine Based on DSP

    International Nuclear Information System (INIS)

    Gao, Y H; Tian, X L; Cheng, P; Chang, X; Dou, W J

    2006-01-01

    In the paper, the structure, working principle, functions and characteristics of an data acquisition and analysis system for internal combustion engines (I.C. engine) based on DSP is introduced. The DSP can not only acquire and analyze the data alone, also can work with the PC together to form data acquisition and analysis system with high speed and large memory. The system takes advantages of TMS320F2812's plenty of peripherals on chip, becomes small and easy for installation. USB technique is used to translate data between DSP and PC in high speed, so the system's real time processing is proved very much. It is proved that the designed system can acquire and analyze the steady and transient parameters of the I.C. engine very well

  15. The Design and Implementation of a Remote Fault Reasoning Diagnosis System for Meteorological Satellites Data Acquisition

    Directory of Open Access Journals (Sweden)

    Zhu Jie

    2017-01-01

    Full Text Available Under the background of the trouble shooting requirements of FENGYUN-3 (FY-3 meteorological satellites data acquisition in domestic and oversea ground stations, a remote fault reasoning diagnosis system is developed by Java 1.6 in eclipse 3.6 platform. The general framework is analyzed, the workflow is introduced. Based on the system, it can realize the remote and centralized monitoring of equipment running status in ground stations,triggering automatic fault diagnosis and rule based fault reasoning by parsing the equipment quality logs, generating trouble tickets and importing expert experience database, providing text and graphics query methods. Through the practical verification, the system can assist knowledge engineers in remote precise and rapid fault location with friendly graphical user interface, boost the fault diagnosis efficiency, enhance the remote monitoring ability of integrity operating control system. The system has a certain practical significance to improve reliability of FY-3 meteorological satellites data acquisition.

  16. AGS BOOSTER BEAM POSITION, TUNE, AND LONGITUDINAL PROFILE DATA ACQUISITION SYSTEM

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; SEVERINO, F; SMITH, K.; WILINSKI, M

    2003-01-01

    In this paper we will describe a data acquisition system designed and developed for the AGS Booster. The system was motivated by the need to get high quality beam diagnostics from the AGS Booster. This was accomplished by locating the electronics and digital data acquisition close to the Booster ring, to minimize loss of bandwidth in the original signals. In addition we had to develop the system rapidly and at a low cost. The system consists of a Lecroy digital oscilloscope which is interfaced through a National Instruments LabView(trademark) server application, developed for this project. This allows multiple client applications to time share the scope without interfering with each other. We will present a description of the system design along with example clients that we have implemented

  17. The use of a VAX cluster for the DIII-D data acquisition system

    International Nuclear Information System (INIS)

    McHarg, B.B. Jr.

    1991-11-01

    The DIII-D tokamak is a large fusion energy research experiment funded by the Department of Energy. The experiment currently collects nearly 40 Mbytes of data from each shot of the experiment. In the past, most of this data was acquired through the MODCOMP Classic data acquisition computers and then transferred to a DEC VAX computer system for permanent archiving and storage. A much smaller amount of data was acquired from a few MicroVAX based data acquisition systems. In the last two years, MicroVAX based systems have become the standard means for adding new diagnostic data and account for half the total data. There are now 17 VAX systems of various types at the DIII-D facility. As more diagnostics and data are added, it takes increasing of time to merge the data into the central shot file. The system management of so many systems has become increasingly time consuming as well. To improve the efficiency of the overall data acquisition system, a mixed interconnect VAX cluster has been formed consisting of 16 VAX computers. In the cluster, the software protocol for passing data around the cluster is much more efficient than using DECnet. The cluster has also greatly simplified the procedure of backing up disks. Another big improvement is the use of a VAX console system which ties all the console ports of the computers into one central computer system which then manages the entire cluster

  18. Monitoring the data flow of LHCb’s data acquisition system

    CERN Document Server

    Svantesson, David; Rainer, S

    2010-01-01

    The data acquisition system of the Large Hadron Collider beauty (LHCb) experiment need to read out huge amount of data. Monitoring is done for each subsystem but there exist no system to monitor the overall data flow. The aim of this work has been to design a system where the data rates can be vied continuously and making it possible to do an exact consistency check after the run to ensure no data are lost. This involves collecting and processing all necessary data from each subsystem and integrate it into the experiment control system for displaying it to the operators. The challenges are to communicate and collect data from all stages of the data acquisitions system which uses different techniques and data formats. The size of the system also makes it a challenge to gather all statistics in real time. The system must also be able to support partitioning. The result was to build a data flow monitoring system, that acquire statistics from all stages of the data acquisition, process it and display it in the ex...

  19. A microcontroller-based data-acquisition system for meteorological station monitoring

    International Nuclear Information System (INIS)

    Rosiek, S.; Batlles, F.J.

    2008-01-01

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out

  20. A microcontroller-based data-acquisition system for meteorological station monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, S.; Batlles, F.J. [Dpto. Fisica Aplicada, Universidad de Almeria, 04120 Almeria (Spain)

    2008-12-15

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from the University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out. (author)

  1. Position-controlled data acquisition embedded system for magnetic NDE of bridge stay cables.

    Science.gov (United States)

    Maldonado-Lopez, Rocio; Christen, Rouven

    2011-01-01

    This work presents a custom-tailored sensing and data acquisition embedded system, designed to be integrated in a new magnetic NDE inspection device under development at Empa, a device intended for routine testing of large diameter bridge stay cables. The data acquisition (DAQ) system fulfills the speed and resolution requirements of the application and is able to continuously capture and store up to 2 GB of data at a sampling rate of 27 kS/s, with 12-bit resolution. This paper describes the DAQ system in detail, including both hardware and software implementation, as well as the key design challenges and the techniques employed to meet the specifications. Experimental results showing the performance of the system are also presented.

  2. The Data Acquisition and Calibration System for the ATLAS Semiconductor Tracker

    CERN Document Server

    Abdesselam, A; Barr, A J; Bell, P; Bernabeu, J; Butterworth, J M; Carter, J R; Carter, A A; Charles, E; Clark, A; Colijn, A P; Costa, M J; Dalmau, J M; Demirkoz, B; Dervan, P J; Donega, M; D'Onifrio, M; Escobar, C; Fasching, D; Ferguson, D P S; Ferrari, P; Ferrère, D; Fuster, J; Gallop, B; García, C; González, S; González-Sevilla, S; Goodrick, M J; Gorisek, A; Greenall, A; Grillo, A A; Hessey, N P; Hill, J C; Jackson, J N; Jared, R C; Johannson, P D C; de Jong, P; Joseph, J; Lacasta, C; Lane, J B; Lester, C G; Limper, M; Lindsay, S W; McKay, R L; Magrath, C A; Mangin-Brinet, M; Martí i García, S; Mellado, B; Meyer, W T; Mikulec, B; Minano, M; Mitsou, V A; Moorhead, G; Morrissey, M; Paganis, E; Palmer, M J; Parker, M A; Pernegger, H; Phillips, A; Phillips, P W; Postranecky, M; Robichaud-Véronneau, A; Robinson, D; Roe, S; Sandaker, H; Sciacca, F; Sfyrla, A; Stanecka, E; Stapnes, S; Stradling, A; Tyndel, M; Tricoli, A; Vickey, T; Vossebeld, J H; Warren, M R M; Weidberg, A R; Wells, P S; Wu, S L

    2008-01-01

    The SemiConductor Tracker (SCT) data acquisition (DAQ) system will calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It will provide a synchronized bunch-crossing clock to the front-end modules, communicate first-level triggers to the front-end chips, and transfer information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded nearly twenty million synchronously-triggered events during commissioning tests including almost a million cosmic ray triggered events. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests.

  3. The data acquisition and calibration system for the ATLAS Semiconductor Tracker

    International Nuclear Information System (INIS)

    Abdesselam, A; Barr, A J; Demirkoez, B; Barber, T; Carter, J R; Bell, P; Bernabeu, J; Costa, M J; Escobar, C; Butterworth, J M; Carter, A A; Dalmau, J M; Charles, E; Fasching, D; Ferguson, D P S; Clark, A; Donega, M; D'Onifrio, M; Colijn, A-P; Dervan, P J

    2008-01-01

    The SemiConductor Tracker (SCT) data acquisition (DAQ) system will calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It will provide a synchronized bunch-crossing clock to the front-end modules, communicate first-level triggers to the front-end chips, and transfer information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded nearly twenty million synchronously-triggered events during commissioning tests including almost a million cosmic ray triggered events. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests

  4. Data acquisition system for the socal plane detector of the mass separator MASHA

    Science.gov (United States)

    Novoselov, A. S.; Rodin, A. M.; Motycak, S.; Podshibyakin, A. V.; Krupa, L.; Belozerov, A. V.; Vedeneyev, V. Yu.; Gulyaev, A. V.; Gulyaeva, A. V.; Kliman, J.; Salamatin, V. S.; Stepantsov, S. V.; Chernysheva, E. V.; Yukhimchuk, S. A.; Komarov, A. B.; Kamas, D.

    2016-09-01

    The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov laboratory of nuclear reactions at Joint institute for nuclear research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.

  5. Data acquisition system for the focal-plane detector of the mass separator MASHA

    International Nuclear Information System (INIS)

    Novoselov, A.S.; Rodin, A.M.; Podshibyakin, A.V.; Belozerov, A.V.; Vedeneyev, V.Yu.; Gulyaev, A.V.; Gulyaeva, A.V.; Salamatin, V.S.; Stepantsov, S.V.; Chernysheva, E.V.; Yukhimchuk, S.A.; Komarov, A.B.; Motycak, S.; Krupa, L.; Kliman, J.; Kamas, D.

    2016-01-01

    The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov Laboratory of Nuclear Reactions at the Joint Institute for Nuclear Research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment the system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal-plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.

  6. Low level signal data acquisition for the MFTF-B superconducting magnet system

    International Nuclear Information System (INIS)

    Montoya, C.R.

    1984-01-01

    Acquisition of low level signals from sensors mounted on the superconducting magnets in the Tandem Mirror Fusion Test Facility (MFTF-B) impose very strict requirements on the magnet signal conditioning and data acquisition system. Of the various types of sensors required, thermocouples and strain gages produce very low level outputs. These low level outputs must be accurately measured in the harsh environment of slowly varying magnetic fields, cryogenic temperatures, high vacuum, 80 kV pulse power, 60 Hz, 17 MHz and 28, 35, and 56 GHz electrical noise and possible neutron radiation. Successful measurements require careful attention to grounding, shielding, signal handling and processing in the data acquisition system. The magnet instrumentation system provides a means of effectively measuring both low level signals and high level signals from all types of sensors. Various methods involved in the design and implementation of the system for signal conditioning and data gathering will be presented

  7. ''Big Dee'' upgrade of the Doublet III diagnostic data acquisition computer system

    International Nuclear Information System (INIS)

    Mcharg, B.B.

    1983-01-01

    The ''Big Dee'' upgrade of the Doublet III tokamak facility will begin operation in 1986 with an initial quantity of data expected to be 10 megabytes per shot and eventually attaining 20-25 megabytes per shot. This is in comparison to the 4-5 megabytes of data currently acquired. To handle this greater quantity of data and to serve physics needs for significantly improved between-shot processing of data will require a substantial upgrade of the existing data acquisition system. The key points of the philosophy that have been adopted for the upgraded system to handle the greater quantity of data are (1) preserve existing hardware, (2) preserve existing software; (3) configure the system in a modular fashion; and (4) distribute the data acquisition over multiple computers. The existing system using ModComp CLASSIC 16 bit minicomputers is capable of handling 5 megabytes of data per shot

  8. Big Dee upgrade of the Doublet III diagnostic data acquisition computer system

    International Nuclear Information System (INIS)

    McHarg, B.B. Jr.

    1983-12-01

    The Big Dee upgrade of the Doublet III tokamak facility will begin operation in 1986 with an initial quantity of data expected to be 10 megabytes per shot and eventually attaining 20 to 25 megabytes per shot. This is in comparison to the 4 to 5 megabytes of data currently acquired. To handle this greater quantity of data and to serve physics needs for significantly improved between-shot processing of data will require a substantial upgrade of the existing data acquisition system. The key points of the philosophy that have been adopted for the upgraded system to handle the greater quantity of data are (1) preserve existing hardware; (2) preserve existing software; (3) configure the system in a modular fashion; and (4) distribute the data acquisition over multiple computers. The existing system using ModComp CLASSIC 16 bit minicomputers is capable of handling 5 megabytes of data per shot

  9. ASRC Aerospace Corporation Selects Dynamically Reconfigurable Anadigm(Registered Trademark) FPAA For Advanced Data Acquisition System

    Science.gov (United States)

    Mata, Carlos T.

    2003-01-01

    Anadigm(registered trademark) today announced that ASRC Aerospace Corporation has designed Anadigm's dynamically reconfigurable Field Programmable Analog Array (FPAA) technology into an advanced data acquisition system developed under contract for NASA. ASRC Aerospace designed in the Anadigm(registered trademark) FPAA to provide complex analog signal conditioning in its intelligent, self-calibrating, and self-healing advanced data acquisition system (ADAS). The ADAS has potential applications in industrial, manufacturing, and aerospace markets. This system offers highly reliable operation while reducing the need for user interaction. Anadigm(registered trademark)'s dynamically reconfigurable FPAAs can be reconfigured in-system by the designer or on the fly by a microprocessor. A single device can thus be programmed to implement multiple analog functions and/or to adapt on-the-fly to maintain precision operation despite system degradation and aging. In the case of the ASRC advanced data acquisition system, the FPAA helps ensure that the system will continue to operating at 100% functionality despite changes in the environment, component degradation, and/or component failures.

  10. The use of a VAX cluster for the DIII-D data acquisition system

    International Nuclear Information System (INIS)

    McHarg, B.B. Jr.

    1992-01-01

    This paper reports on the DIII-D tokamak, a large fusion energy research experiment funded by the Department of Energy. The experiment currently collects nearly 40 Mbytes of data from each shot of the experiment. In the past, most of this data was acquired through the MODCOMP Classic data acquisition computers and then transferred to a DEC VAX computer system for permanent archiving and storage. A much smaller amount of data was acquired from a few Micro VAX based data acquisition systems. In the last two years, MicroVAX based systems have become the standard means for adding new diagnostic data and account for half the total data. There are now 17 VAX systems of various types at the DIII-D facility. As more diagnostics and data are added, it takes increasing amounts of time to merge the data into the central shot file. The system management of so many systems has become increasingly time consuming as well. To improve the efficiency of the overall data acquisition system, a mixed interconnect VAX cluster has been formed consisting of 16 VAX computers

  11. Conceptual design of the CEM design of the data acquisition system

    International Nuclear Information System (INIS)

    Bowden, M.; Dorenbosch, J.; Kapoor, V.

    1993-06-01

    The design of a large scale data acquisition system for the GEM detector at the Superconducting Super Collider (SSC) is presented. This architecture supports high-bandwidth data transfer using parallel point-to-point links and a scalable switching network. Substantial buffering enables the use of high latency, selective triggering based on either hardware or software implementations. The system throughput can be expanded to greater than 40 Gbps per second at trigger rates of 100 KHz

  12. Real time data acquisition system for the High Current Test Facility proton accelerator

    International Nuclear Information System (INIS)

    Langlais, C.E.; Erickson, P.D.; Caissie, L.P.

    1975-01-01

    A real time data acquisition system was developed to monitor and control the High Current Test Facility Proton Accelerator. It is a PDP-8/E computer system with virtual memory capability that is fully interrupt driven and operates under a real-time, multi-tasking executive. The application package includes mode selection to automatically modify programs and optimize operation under varying conditions. (U.S.)

  13. Preliminary thoughts on the data acquisition for the next generation of silicon tracking systems

    International Nuclear Information System (INIS)

    Genat, J.F.; Savoy-Navarro, A.

    2007-01-01

    Preliminary thoughts about the data acquisition system to be developed for the next generation of large area silicon tracker are presented in this paper. This paper describes the set of data delivered by these tracking systems, and the various stages of processing and data flow transmission from the front-end chip sitting on the detector to the latest stage in the data processing. How to best profit from the status of the art technologies is a major goal. (author)

  14. Lessons learned from designing and commissioning a versatile data acquisiting system for an accelerator development facility

    International Nuclear Information System (INIS)

    Langlais, C.E.; Watkins, L.M.; Caissie, L.P.; Wachsmann, W.J.; Andison, C.E.

    1977-01-01

    Achieving reliable operation of digital equipment under extreme noise conditions presents special challenges to system designers. Experience with the design and operation of a data acquisition and control system for an accelerator development facility at the Chalk River Nuclear Laboratories is reviewed. It is concluded that, by adhering to a few rules in developing both the hardware and the software, satisfactory performance can be guaranteed. Methods of producing a reliable design are presented

  15. CLASSIFICATION OF THE MGR PERFORMANCE CONFIRMATION DATA ACQUISITION/MONITORING SYSTEM

    International Nuclear Information System (INIS)

    J.A. Ziegler

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) performance confirmation data acquisition/monitoring system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMF 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333PY ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  16. Integrating a sampling oscilloscope card and spectroscopy ADCs in a data acquisition system

    CERN Document Server

    Maartensson, L

    2001-01-01

    A high-rate sampling oscilloscope card has been integrated into an existing data acquisition system for spectroscopy ADCs. Experiments where pulse-shape analyses are important have then been made possible. Good performance characteristics of the integrated system have been achieved. Spectroscopy ADC data together with pulse-shape data sampled 512 times at 100 MHz are saved to hard disk at event rates up to about 1 kHz with low dead time losses.

  17. 1024-65536 channel nuclear spectrum data acquisition and processing system

    Energy Technology Data Exchange (ETDEWEB)

    Songjiang, Xia

    1987-09-01

    A multiscale data acquisition and processing system based on IBM PC/XT microcomputer is described. In this system, not only 1024,2048,4096 single parameter spectrum, but also 128 x 128, 256 x 256 dual parameter spectrum can be acquisited. The interface logic is designed to work at sequential recording DMA mode, the total avergage time for recording each descriptor is 7.5 ..mu..s.

  18. Timing performances of a data acquisition system for Time of Flight PET

    International Nuclear Information System (INIS)

    Morrocchi, Matteo; Marcatili, Sara; Belcari, Nicola; Bisogni, Maria G.; Collazuol, Gianmaria; Ambrosi, Giovanni; Corsi, Francesco; Foresta, Maurizio; Marzocca, Cristoforo; Matarrese, Gianvito; Sportelli, Giancarlo; Guerra, Pedro; Santos, Andres; Del Guerra, Alberto

    2012-01-01

    We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm 2 of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.

  19. Timing performances of a data acquisition system for Time of Flight PET

    Energy Technology Data Exchange (ETDEWEB)

    Morrocchi, Matteo, E-mail: matteo.morrocchi@pi.infn.it [University of Pisa and INFN Sezione di Pisa, I 56127 Pisa (Italy); Marcatili, Sara; Belcari, Nicola; Bisogni, Maria G. [University of Pisa and INFN Sezione di Pisa, I 56127 Pisa (Italy); Collazuol, Gianmaria [University of Padova and INFN Sezione di Padova (Italy); Ambrosi, Giovanni [INFN Sezione di Perugia, I 06100 Perugia (Italy); Corsi, Francesco; Foresta, Maurizio; Marzocca, Cristoforo; Matarrese, Gianvito [Politecnico di Bari and INFN Sezione di Bari, I 70100 Bari (Italy); Sportelli, Giancarlo; Guerra, Pedro; Santos, Andres [Universidad Politecnica de Madrid, E 28040 Madrid (Spain); Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Del Guerra, Alberto [University of Pisa and INFN Sezione di Pisa, I 56127 Pisa (Italy)

    2012-12-11

    We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm{sup 2} of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.

  20. Data acquisition and processing system of energy dispersive X-ray spectrometer with microprocessor

    International Nuclear Information System (INIS)

    Horkay, G.; Kis-Varga, M.; Lakatos, T.; Molnar, J.; Zsurzs, M.

    1984-01-01

    For quantitative analysis of chemical elements by the method of X-ray spectroscopy a multichannel analyzer on the base of minicomputer with the INTEL 8080 A microprocessor is developed. The data acquisition and data processing systems which comprise a central processor, memory unit, ADC and display are described. Major system subprograms are enumerated. An example of Pb concentration determinating in a bronze specimen is given