WorldWideScience

Sample records for low-level human equivalent

  1. Low-level human equivalent gestational lead exposure produces sex-specific motor and coordination abnormalities and late-onset obesity in year-old mice.

    Science.gov (United States)

    Leasure, J Leigh; Giddabasappa, Anand; Chaney, Shawntay; Johnson, Jerry E; Pothakos, Konstantinos; Lau, Yuen Sum; Fox, Donald A

    2008-03-01

    Low-level developmental lead exposure is linked to cognitive and neurological disorders in children. However, the long-term effects of gestational lead exposure (GLE) have received little attention. Our goals were to establish a murine model of human equivalent GLE and to determine dose-response effects on body weight, motor functions, and dopamine neurochemistry in year-old offspring. We exposed female C57BL/6 mice to water containing 0, 27 (low), 55 (moderate), or 109 ppm (high) of lead from 2 weeks prior to mating, throughout gestation, and until postnatal day 10 (PN10). Maternal and litter measures, blood lead concentrations ([BPb]), and body weights were obtained throughout the experiment. Locomotor behavior in the absence and presence of amphetamine, running wheel activity, rotarod test, and dopamine utilization were examined in year-old mice. Peak [BPb] were obesity. Similarly, we observed male-specific decreased spontaneous motor activity, increased amphetamine-induced motor activity, and decreased rotarod performance in year-old GLE mice. Levels of dopamine and its major metabolite were altered in year-old male mice, although only forebrain utilization increased. GLE-induced alterations were consistently larger in low-dose GLE mice. Our novel results show that GLE produced permanent male-specific deficits. The nonmonotonic dose-dependent responses showed that low-level GLE produced the most adverse effects. These data reinforce the idea that lifetime measures of dose-response toxicant exposure should be a component of the neurotoxic risk assessment process.

  2. Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction

    Directory of Open Access Journals (Sweden)

    Lehmann RP

    2012-03-01

    Full Text Available Robert P Lehmann1, Diane M Houtman21Lehmann Eye Center, Nacogdoches, TX, 2Alcon Research Ltd, Fort Worth, TX, USAPurpose: To evaluate whether visual performance could be improved in pseudophakic subjects by correcting low levels of postoperative astigmatism.Methods: An exploratory, noninterventional study was conducted using subjects who had been implanted with an aspheric intraocular lens and had 0.5–0.75 diopter postoperative astigmatism. Monocular visual performance using full correction was compared with visual performance using spherical equivalent correction. Testing consisted of high- and low-contrast visual acuity, contrast sensitivity, and reading acuity and speed using the Radner Reading Charts.Results: Thirty-eight of 40 subjects completed testing. Visual acuities at three contrast levels (100%, 25%, and 9% were significantly better using full correction than when using spherical equivalent correction (all P < 0.001. For contrast sensitivity testing under photopic, mesopic, and mesopic with glare conditions, only one out of twelve outcomes demonstrated a significant improvement with full correction compared with spherical equivalent correction (at six cycles per degree under mesopic without glare conditions, P = 0.046. Mean reading speed was numerically faster with full correction across all print sizes, reaching statistical significance at logarithm of the reading acuity determination (logRAD 0.2, 0.7, and 1.1 (P , 0.05. Statistically significant differences also favored full correction in logRAD score (P = 0.0376, corrected maximum reading speed (P < 0.001, and logarithm of the minimum angle of resolution/logRAD ratio (P < 0.001.Conclusions: In this study of pseudophakic subjects with low levels of postoperative astigmatism, full correction yielded significantly better reading performance and high- and low-contrast visual acuity than spherical equivalent correction, suggesting that cataractous patients may benefit from surgical

  3. High-fructose corn syrup and sucrose have equivalent effects on energy-regulating hormones at normal human consumption levels.

    Science.gov (United States)

    Yu, Zhiping; Lowndes, Joshua; Rippe, James

    2013-12-01

    Intake of high-fructose corn syrup (HFCS) has been suggested to contribute to the increased prevalence of obesity, whereas a number of studies and organizations have reported metabolic equivalence between HFCS and sucrose. We hypothesized that HFCS and sucrose would have similar effects on energy-regulating hormones and metabolic substrates at normal levels of human consumption and that these values would not change over a 10-week, free-living period at these consumption levels. This was a randomized, prospective, double-blind, parallel group study in which 138 adult men and women consumed 10 weeks of low-fat milk sweetened with either HFCS or sucrose at levels of the 25th, 50th, and 90th percentile population consumption of fructose (the equivalent of 40, 90, or 150 g of sugar per day in a 2000-kcal diet). Before and after the 10-week intervention, 24-hour blood samples were collected. The area under the curve (AUC) for glucose, insulin, leptin, active ghrelin, triglyceride, and uric acid was measured. There were no group differences at baseline or posttesting for all outcomes (interaction, P > .05). The AUC response of glucose, active ghrelin, and uric acid did not change between baseline and posttesting (P > .05), whereas the AUC response of insulin (P < .05), leptin (P < .001), and triglyceride (P < .01) increased over the course of the intervention when the 6 groups were averaged. We conclude that there are no differences in the metabolic effects of HFCS and sucrose when compared at low, medium, and high levels of consumption. © 2013 Elsevier Inc. All rights reserved.

  4. Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am–Be neutron source

    International Nuclear Information System (INIS)

    Li, Gang; Xu, Jiayun; Zhang, Jie

    2015-01-01

    Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am–Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am–Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. - Highlights: • The scope of the affected area for

  5. Human exposure to low level ionising radiation

    International Nuclear Information System (INIS)

    Paix, David

    1988-01-01

    This paper describes the low-level radiation sources and their effects on human populations, from a global perspective. 'Low-level' means exposures in the range of the natural background to which everybody is exposed. The quoted values are whole-world averages, but individual variations are mentioned in a few cases. (author). 22 refs

  6. Equivalence of velocity-level and acceleration-level redundancy-resolution of manipulators

    International Nuclear Information System (INIS)

    Cai Binghuang; Zhang Yunong

    2009-01-01

    The equivalence of velocity-level and acceleration-level redundancy resolution of robot manipulators is investigated in this Letter. Theoretical analysis based on gradient-descent method and computer simulations based on PUMA560 robot manipulator both demonstrate the equivalence of redundancy-resolution schemes at different levels.

  7. Effects of low levels of radiation on humans

    International Nuclear Information System (INIS)

    Auxier, J.A.

    1981-01-01

    The state of knowledge on effects of low-level ionizing radiations on humans is reviewed. Several problems relating to dose thresholds or lack of thresholds for several types of cancer and high LET radiations and the effects of fractionation and dose protection are discussed

  8. Reconstruction of living bilayer human skin equivalent utilizing human fibrin as a scaffold.

    Science.gov (United States)

    Mazlyzam, A L; Aminuddin, B S; Fuzina, N H; Norhayati, M M; Fauziah, O; Isa, M R; Saim, L; Ruszymah, B H I

    2007-05-01

    Our aim of this study was to develop a new methodology for constructing a bilayer human skin equivalent to create a more clinical compliance skin graft composite for the treatment of various skin defects. We utilized human plasma derived fibrin as the scaffold for the development of a living bilayer human skin equivalent: fibrin-fibroblast and fibrin-keratinocyte (B-FF/FK SE). Skin cells from six consented patients were culture-expanded to passage 1. For B-FF/FK SE formation, human fibroblasts were embedded in human fibrin matrix and subsequently another layer of human keratinocytes in human fibrin matrix was stacked on top. The B-FF/FK SE was then transplanted to athymic mice model for 4 weeks to evaluate its regeneration and clinical performance. The in vivo B-FF/FK SE has similar properties as native human skin by histological analysis and expression of basal Keratin 14 gene in the epidermal layer and Collagen type I gene in the dermal layer. Electron microscopy analysis of in vivo B-FF/FK SE showed well-formed and continuous epidermal-dermal junction. We have successfully developed a technique to engineer living bilayer human skin equivalent using human fibrin matrix. The utilization of culture-expanded human skin cells and fibrin matrix from human blood will allow a fully autologous human skin equivalent construction.

  9. Low-level lasers on microRNA and uncoupling protein 2 mRNA levels in human breast cancer cells

    Science.gov (United States)

    Canuto, K. S.; Teixeira, A. F.; Rodrigues, J. A.; Paoli, F.; Nogueira, E. M.; Mencalha, A. L.; Fonseca, A. S.

    2017-06-01

    MicroRNA is short non-coding RNA and is a mediator of post-transcriptional regulation of gene expression. In addition, uncoupling proteins (UCPs) regulate thermogenesis, metabolic and energy balance, and decrease reactive oxygen species production. Both microRNA and UCP2 expression can be altered in cancer cells. At low power, laser wavelength, frequency, fluence and emission mode deternube photobiological responses, which are the basis of low-level laser therapy. There are few studies on miRNA and UCP mRNA levels after low-level laser exposure on cancer cells. In this work, we evaluate the micrRNA (mir-106b and mir-15a) and UCP2 mRNA levels in human breast cancer cells exposed to low-level lasers. MDA-MB-231 human breast cancer cells were exposed to low-level red and infrared lasers, total RNA was extracted for cDNA synthesis and mRNA levels by real time quantitative polymerase chain reaction were evaluated. Data show that mir-106b and mir-15a relative levels are not altered, but UCP2 mRNA relative levels are increased in MDA-MB-231 human breast cancer cells exposed to low-level red and infrared lasers at fluences used in therapeutic protocols.

  10. Asynchronous replication and autosome-pair non-equivalence in human embryonic stem cells.

    Directory of Open Access Journals (Sweden)

    Devkanya Dutta

    Full Text Available A number of mammalian genes exhibit the unusual properties of random monoallelic expression and random asynchronous replication. Such exceptional genes include genes subject to X inactivation and autosomal genes including odorant receptors, immunoglobulins, interleukins, pheromone receptors, and p120 catenin. In differentiated cells, random asynchronous replication of interspersed autosomal genes is coordinated at the whole chromosome level, indicative of chromosome-pair non-equivalence. Here we have investigated the replication pattern of the random asynchronously replicating genes in undifferentiated human embryonic stem cells, using fluorescence in situ hybridization based assay. We show that allele-specific replication of X-linked genes and random monoallelic autosomal genes occur in human embryonic stem cells. The direction of replication is coordinated at the whole chromosome level and can cross the centromere, indicating the existence of autosome-pair non-equivalence in human embryonic stem cells. These results suggest that epigenetic mechanism(s that randomly distinguish between two parental alleles are emerging in the cells of the inner cell mass, the source of human embryonic stem cells.

  11. Evaluation of 3D-human skin equivalents for assessment of human dermal absorption of some brominated flame retardants.

    Science.gov (United States)

    Abdallah, Mohamed Abou-Elwafa; Pawar, Gopal; Harrad, Stuart

    2015-11-01

    Ethical and technical difficulties inherent to studies in human tissues are impeding assessment of the dermal bioavailability of brominated flame retardants (BFRs). This is further complicated by increasing restrictions on the use of animals in toxicity testing, and the uncertainties associated with extrapolating data from animal studies to humans due to inter-species variations. To overcome these difficulties, we evaluate 3D-human skin equivalents (3D-HSE) as a novel in vitro alternative to human and animal testing for assessment of dermal absorption of BFRs. The percutaneous penetration of hexabromocyclododecanes (HBCD) and tetrabromobisphenol-A (TBBP-A) through two commercially available 3D-HSE models was studied and compared to data obtained for human ex vivo skin according to a standard protocol. No statistically significant differences were observed between the results obtained using 3D-HSE and human ex vivo skin at two exposure levels. The absorbed dose was low (less than 7%) and was significantly correlated with log Kow of the tested BFR. Permeability coefficient values showed increasing dermal resistance to the penetration of γ-HBCD>β-HBCD>α-HBCD>TBBPA. The estimated long lag times (>30 min) suggests that frequent hand washing may reduce human exposure to HBCDs and TBBPA via dermal contact. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent

    International Nuclear Information System (INIS)

    Eisen, Y.

    1986-01-01

    The performance of Rossi-type spherical tissue-equivalent chambers with equivalent diameters between 0.5 μm and 2 μm was tested experimentally using monoenergetic and polyenergetic neutron sources in the energy region of 10 keV to 14.5 MeV. In agreement with theoretical predictions both chambers failed to provide LET information at low neutron energies. A dose equivalent algorithm was derived that utilises the event distribution but does not attempt to correlate event size with LET. The algorithm was predicted theoretically and confirmed by experiment. The algorithm that was developed determines the neutron dose equivalent, from the data of the 0.5 μm chamber, to better than +-20% over the energy range of 30 keV to 14.5 MeV. The same algorithm also determines the dose equivalent from the data of the 2 μm chamber to better than +-20% over the energy range of 60 keV to 14.5 MeV. The efficiency of the chambers is 33 counts per μSv, or equivalently about 10 counts s -1 per mSv.h -1 . This efficiency enables the measurement of dose equivalent rates above 1 mSv.h -1 for an integration period of 3 s. Integrated dose equivalents can be measured as low as 1 μSv. (author)

  13. Neutron spectrometry for protection dosimetry at very low levels

    International Nuclear Information System (INIS)

    Bardell, A.G.; Thomas, D.J.

    1996-01-01

    Dose limits for exposure of members of the public are significantly lower than those for designated radiation workers. The new ICRP 60 recommendation for critical groups of the general public is an effective dose limit of 1 mSv per year which requires a measurement capability at levels down to about 100 nSv h - 1. Radiation protection dosimetry for neutrons at these levels is problematical, nevertheless, operators of nuclear sites are still required to demonstrate acceptably low radiation levels in areas accessible to the public. In addition to the known poor dose equivalent response of available dosemeters, there is an added problem at low levels of inadequate sensitivity. Personal dosemeters are certainly not sufficiently sensitive, and the sensitivity of area survey instruments is such that they can only be used in integral mode Even then, the statistical uncertainties are likely to be large. One further problem concerns the quantity measured. Survey instruments are designed to measure the operational quantity ambient dose equivalent, H*(10), which always tends to be an overestimate of the present limiting quantity effective dose equivalent. If in any situation exposure is near the limit, an estimate of H*(10) may not be sufficient to prove conclusively that levels are less than the statutory limit, and a direct estimate of effective dose equivalent may need to be made. The only way of estimating effective dose equivalent is via an absolute spectral measurement. From such a spectrum any relevant dosimetric quantity can be estimated via tabulated fluence to dose equivalent conversion factors. (Certain quantities also require information about the angular dependence of the field - see later text). Spectrometry at such low neutron fluence levels is difficult, however, there is one instrument available which can perform the required measurements, and this is a well characterised Bonner sphere (BS) set. (author)

  14. Application of equivalent electrodes method to analysis of interaction between ELF-LF electric fields and human body

    International Nuclear Information System (INIS)

    Ceselkoska, Vesna C.; Velickovic, Dragutin M.

    2002-01-01

    This paper presents the use of equivalent electrodes method, numerical method, based on surface-charge equation to quantify the interaction of low frequencies electric fields with various models of human body. The evaluation of the electric field intensity on the body surface is performed for a realistic model of the human body. Several examples for different postures of the model are given. (Author)

  15. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  16. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  17. Task Equivalence for Model and Human-Observer Comparisons in SPECT Localization Studies

    Science.gov (United States)

    Sen, Anando; Kalantari, Faraz; Gifford, Howard C.

    2016-06-01

    While mathematical model observers are intended for efficient assessment of medical imaging systems, their findings should be relevant for human observers as the primary clinical end users. We have investigated whether pursuing equivalence between the model and human-observer tasks can help ensure this goal. A localization receiver operating characteristic (LROC) study tested prostate lesion detection in simulated In-111 SPECT imaging with anthropomorphic phantoms. The test images were 2D slices extracted from reconstructed volumes. The iterative ordered sets expectation-maximization (OSEM) reconstruction algorithm was used with Gaussian postsmoothing. Variations in the number of iterations and the level of postfiltering defined the test strategies in the study. Human-observer performance was compared with that of a visual-search (VS) observer, a scanning channelized Hotelling observer, and a scanning channelized nonprewhitening (CNPW) observer. These model observers were applied with precise information about the target regions of interest (ROIs). ROI knowledge was a study variable for the human observers. In one study format, the humans read the SPECT image alone. With a dual-modality format, the SPECT image was presented alongside an anatomical image slice extracted from the density map of the phantom. Performance was scored by area under the LROC curve. The human observers performed significantly better with the dual-modality format, and correlation with the model observers was also improved. Given the human-observer data from the SPECT study format, the Pearson correlation coefficients for the model observers were 0.58 (VS), -0.12 (CH), and -0.23 (CNPW). The respective coefficients based on the human-observer data from the dual-modality study were 0.72, 0.27, and -0.11. These results point towards the continued development of the VS observer for enhancing task equivalence in model-observer studies.

  18. Equivalent magnetic vector potential model for low-frequency magnetic exposure assessment

    Science.gov (United States)

    Diao, Y. L.; Sun, W. N.; He, Y. Q.; Leung, S. W.; Siu, Y. M.

    2017-10-01

    In this paper, a novel source model based on a magnetic vector potential for the assessment of induced electric field strength in a human body exposed to the low-frequency (LF) magnetic field of an electrical appliance is presented. The construction of the vector potential model requires only a single-component magnetic field to be measured close to the appliance under test, hence relieving considerable practical measurement effort—the radial basis functions (RBFs) are adopted for the interpolation of discrete measurements; the magnetic vector potential model can then be directly constructed by summing a set of simple algebraic functions of RBF parameters. The vector potentials are then incorporated into numerical calculations as the equivalent source for evaluations of the induced electric field in the human body model. The accuracy and effectiveness of the proposed model are demonstrated by comparing the induced electric field in a human model to that of the full-wave simulation. This study presents a simple and effective approach for modelling the LF magnetic source. The result of this study could simplify the compliance test procedure for assessing an electrical appliance regarding LF magnetic exposure.

  19. Subjective annoyance caused by indoor low-level and low frequency noise and control method

    Institute of Scientific and Technical Information of China (English)

    DI Guo-qing; ZHANG Bang-jun; SHANG Qi

    2005-01-01

    The influence of low-level noise has not been widely noticed. This paper discovered that low-level and low frequency noise(Aweighted equivalent level Leq < 45 dB) causes higher probability of subjective annoyance. The fuzzy mathematic principle was applied to deal with the threshold level of subjective annoyance from noise in this study; there is preferable relationship between the indoor noise and noise annoyance at low frequency noise level. Study indicated at the same centered noise level, the change of annoyance probability is mainly caused by the change of the frequency spectrum characteristic of the indoor noise. Under low noise level environment, without change of the medium-low frequency noise, the slight increase of medium-high frequency noise level with the help of noise sheltering effect can significantly reduce the noise annoyance. This discovery brings a new resolution on how to improve the environmental quality of working or living places. A noise control model is given in this study according to the acoustic analysis.

  20. Alternatives to dose, quality factor and dose equivalent for low level irradiation

    International Nuclear Information System (INIS)

    Sondhaus, C.A.; Bond, V.P.; Feinendegen, L.E.

    1988-01-01

    Randomly occurring energy deposition events produced by low levels of ionizing radiation interacting with tissue deliver variable amounts of energy to the sensitive target volumes within a small fraction of the cell population. A model is described in which an experimentally derived function relating event size to cell response probability operates mathematically on the microdosimetric event size distribution characterizing a given irradiation and thus determines the total fractional number of responding cells; this fraction measures the effectiveness of the given radiation. Normalizing to equal numbers of events produced by different radiations and applying this cell response or hit size effectiveness function (HSEF) should define radiation quality, or relative effectiveness, on a more nearly absolute basis than do the absorbed dose and dose evaluation, which are confounded when applied to low level irradiations. Examples using both calculation and experimental data are presented. 15 refs., 18 figs

  1. Development of human skin equivalents mimicking skin aging : contrast between papillary and reticular fibroblasts as a lead

    NARCIS (Netherlands)

    Janson, D.

    2017-01-01

    This thesis describes the development of human skin equivalents that show characteristics of skin aging. The type of skin equivalent used was a fibroblast derived matrix equivalent, in which the dermal compartment is generated by fibroblasts and thus is fully of human origin. Two strategies are

  2. Over-expression of CXCR4, a stemness enhancer, in human blastocysts by low level laser irradiation

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Tahmasbi

    2013-09-01

    Full Text Available The key role of chemokine receptor CXCR4 in the maintenance of stemness property of stem cells has been shown recently. The low level laser irradiation (LLLI is being used currently in a wide variety of clinical cases as a therapeutic tool for wound healing, relieving pain and destroying tumor cells. The aim of this study was to evaluate the effect of LLLI mimicking low level laser therapy (LLLT on the expression level of CXCR4 gene a few hours after irradiation on human blastocysts. After the development of human embryos to the first grade blastocyst stage, they were irradiated with a low power Ga-Al-As laser at a continuous wavelength of 650 nm and a power output of 30 mW. The total RNA of the irradiated blastocysts and control groups were isolated in groups of 1x2 J/cm2, 2x2 J/cm2, 1x4 J/cm2 and 2x4 J/cm2 LLLI. Specific Real-Time PCR primers were designed to amplify all the two CXCR4 isoforms yet identified. RNA amplifications were done for all the groups. We showed for the first time that LLLI makes the human blastocysts to increase the expression level of CXCR4 a few hours after irradiation. Moreover, it was shown that two irradiation doses with one day interval can cause a significant increase in CXCR4 expression level in human blastocysts. This study revealed that LLLI could be a proliferation motivator for embryonic cell divisions through enhanced over-expression of CXCR4 level.

  3. Low-level radwaste engineering economics

    International Nuclear Information System (INIS)

    Jacobs, M.H.; Miller, C.C.; Young, L.G.

    1984-07-01

    This topical report on engineering economics for low-level radwaste systems details the methodologies used for economic analyses of radwaste treatment systems and provides examples of radwaste economic evaluations. All of the parameters and cost items used in an evaluation are defined. Examples of the present-value-of-revenue-requirements method, levelized-revenue-requirements method, and the equivalent-capital-investment method are provided. Also, the calculation to determine the maximum justifiable capital expenditure for a radwaste system is illustrated. The report also provides examples of economic evaluations for many current radwaste treatment options. These options include evaporation versus demineralization, dewatering resins versus solidification of resins, and several volume reduction systems. 15 figures, 6 tables

  4. Composition of MRI phantom equivalent to human tissues

    International Nuclear Information System (INIS)

    Kato, Hirokazu; Kuroda, Masahiro; Yoshimura, Koichi; Yoshida, Atsushi; Hanamoto, Katsumi; Kawasaki, Shoji; Shibuya, Koichi; Kanazawa, Susumu

    2005-01-01

    We previously developed two new MRI phantoms (called the CAG phantom and the CAGN phantom), with T1 and T2 relaxation times equivalent to those of any human tissue at 1.5 T. The conductivity of the CAGN phantom is equivalent to that of most types of human tissue in the frequency range of 1 to 130 MHz. In this paper, the relaxation times of human tissues are summarized, and the composition of the corresponding phantoms are provided in table form. The ingredients of these phantoms are carrageenan as the gelling agent, GdCl 3 as a T1 modifier, agarose as a T2 modifier, NaCl (CAGN phantom only) as a conductivity modifier, NaN 3 as an antiseptic, and distilled water. The phantoms have T1 values of 202-1904 ms and T2 values of 38-423 ms when the concentrations of GdCl 3 and agarose are varied from 0-140 μmol/kg, and 0%-1.6%, respectively, and the CAGN phantom has a conductivity of 0.27-1.26 S/m when the NaCl concentration is varied from 0%-0.7%. These phantoms have sufficient strength to replicate a torso without the use of reinforcing agents, and can be cut by a knife into any shape. We anticipate the CAGN phantom to be highly useful and practical for MRI and hyperthermia-related research

  5. Expression of DMP-1 in the human pulp tissue using low level laser therapy

    International Nuclear Information System (INIS)

    Neto, Natalino Lourenço; Teixeira Marques, Nádia Carolina; Fernandes, Ana Paula; Silva, Thiago Cruvinel; Andrade Moreira Machado, Maria Aparecida; Oliveira, Thais Marchini; Rodini, Camila Oliveira

    2015-01-01

    This study aimed to evaluate the effects of low-level laser therapy (LLLT) on DMP-1 expression in pulp tissue repair of human primary teeth. Twenty mandibular primary molars were randomly assigned into the following groups: Group I—Buckley’s Formocresol (FC); Group II—Calcium Hydroxide (CH); Group III—LLLT + CH and Group IV—LLLT + Zinc oxide/Eugenol. The teeth at the regular exfoliation period were extracted for histological analysis and immunolocalization of DMP-1. Descriptive analysis was performed on the dentin pulp complex. Histopathological assessment showed internal resorption in group FC. Groups CH and LLLT + CH provided better pulpal repair due to the absence of inflammation and the formation of hard tissue barrier. These two groups presented odontoblastic layer expressing DMP-1. According to this study, low level laser therapy preceding the use of calcium hydroxide exhibited satisfactory bio-inductive activity on pulp tissue repair of human primary teeth. However, other histological and cellular studies are needed to confirm the laser tissue action and efficacy. (paper)

  6. Low level dose induced chromosome aberrations in human blood lymphocytes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Unstable structural aberrations in chromosomes of human blood lymphocytes cannot be used as biological dosemeters in the low dose range, when extrapolating from high doses using a linear dose response, as required by the original formula of the dual radiation action theory. A survey is given of experimental dose-response curves of chromosome aberrations, obtained in investigations not only by this institute, in cooperation with many other laboratories, but also by various authors in different areas of the world. The results are not compatible with the predicted linear dose relationships at in vivo dose ranges up to 30 mGy.y -1 . The aberration frequencies rise sharply with dose within the normal environmental exposure up to about twice that level. At higher doses, aberration frequencies increase less rapidly and reach a plateau. Some in vitro experiments of various authors with higher doses of low LET radiations, up to about 400 mGy have found dose responses with steps. (author)

  7. Equivalent refractive index of the human lens upon accommodative response

    NARCIS (Netherlands)

    Hermans, E.A.; Dubbelman, M.; van der Heijde, R.G.L.; Heethaar, R.M.

    2008-01-01

    PURPOSE.: To experimentally verify the suggestion of Gullstrand (1909), i.e., that the equivalent refractive index of the human lens increases with accommodation. METHODS.: The left eye of five subjects was focused on different accommodation stimuli, while the right eye was imaged with Scheimpflug

  8. The rhesus macaque is three times as diverse but more closely equivalent in damaging coding variation as compared to the human

    Directory of Open Access Journals (Sweden)

    Yuan Qiaoping

    2012-06-01

    Full Text Available Abstract Background As a model organism in biomedicine, the rhesus macaque (Macaca mulatta is the most widely used nonhuman primate. Although a draft genome sequence was completed in 2007, there has been no systematic genome-wide comparison of genetic variation of this species to humans. Comparative analysis of functional and nonfunctional diversity in this highly abundant and adaptable non-human primate could inform its use as a model for human biology, and could reveal how variation in population history and size alters patterns and levels of sequence variation in primates. Results We sequenced the mRNA transcriptome and H3K4me3-marked DNA regions in hippocampus from 14 humans and 14 rhesus macaques. Using equivalent methodology and sampling spaces, we identified 462,802 macaque SNPs, most of which were novel and disproportionately located in the functionally important genomic regions we had targeted in the sequencing. At least one SNP was identified in each of 16,797 annotated macaque genes. Accuracy of macaque SNP identification was conservatively estimated to be >90%. Comparative analyses using SNPs equivalently identified in the two species revealed that rhesus macaque has approximately three times higher SNP density and average nucleotide diversity as compared to the human. Based on this level of diversity, the effective population size of the rhesus macaque is approximately 80,000 which contrasts with an effective population size of less than 10,000 for humans. Across five categories of genomic regions, intergenic regions had the highest SNP density and average nucleotide diversity and CDS (coding sequences the lowest, in both humans and macaques. Although there are more coding SNPs (cSNPs per individual in macaques than in humans, the ratio of dN/dS is significantly lower in the macaque. Furthermore, the number of damaging nonsynonymous cSNPs (have damaging effects on protein functions from PolyPhen-2 prediction in the macaque is more

  9. Disposal of low-level radioactive wastes

    International Nuclear Information System (INIS)

    Hendee, W.R.

    1986-01-01

    The generation of low-level radioactive waste is a natural consequence of the societal uses of radioactive materials. These uses include the application of radioactive materials to the diagnosis and treatment of human disease and to research into the causes of human disease and their prevention. Currently, low level radioactive wastes are disposed of in one of three shallow land-burial disposal sites located in Washington, Nevada, and South Carolina. With the passage in December 1980 of Public Law 96-573, The Low-Level Radioactive Waste Policy Act, the disposal of low-level wastes generated in each state was identified as a responsibility of the state. To fulfill this responsibility, states were encouraged to form interstate compacts for radioactive waste disposal. At the present time, only 37 states have entered into compact agreements, in spite of the clause in Public Law 96-573 that established January 1, 1986, as a target date for implementation of state responsibility for radioactive wastes. Recent action by Congress has resulted in postponement of the implementation date to January 1, 1993

  10. Antimelanogenic Efficacy of Melasolv (3,4,5-Trimethoxycinnamate Thymol Ester) in Melanocytes and Three-Dimensional Human Skin Equivalent.

    Science.gov (United States)

    Lee, John Hwan; Lee, Eun-Soo; Bae, Il-Hong; Hwang, Jeong-Ah; Kim, Se-Hwa; Kim, Dae-Yong; Park, Nok-Hyun; Rho, Ho Sik; Kim, Yong Jin; Oh, Seong-Geun; Lee, Chang Seok

    2017-01-01

    Excessive melanogenesis often causes unaesthetic hyperpigmentation. In a previous report, our group introduced a newly synthesized depigmentary agent, Melasolv™ (3,4,5-trimethoxycinnamate thymol ester). In this study, we demonstrated the significant whitening efficacy of Melasolv using various melanocytes and human skin equivalents as in vitro experimental systems. The depigmentary effect of Melasolv was tested in melan-a cells (immortalized normal murine melanocytes), α-melanocyte-stimulating hormone (α-MSH)-stimulated B16 murine melanoma cells, primary normal human melanocytes (NHMs), and human skin equivalent (MelanoDerm). The whitening efficacy of Melasolv was further demonstrated by photography, time-lapse microscopy, Fontana-Masson (F&M) staining, and 2-photon microscopy. Melasolv significantly inhibited melanogenesis in the melan-a and α-MSH-stimulated B16 cells. In human systems, Melasolv also clearly showed a whitening effect in NHMs and human skin equivalent, reflecting a decrease in melanin content. F&M staining and 2-photon microscopy revealed that Melasolv suppressed melanin transfer into multiple epidermal layers from melanocytes as well as melanin synthesis in human skin equivalent. Our study showed that Melasolv clearly exerts a whitening effect on various melanocytes and human skin equivalent. These results suggest the possibility that Melasolv can be used as a depigmentary agent to treat pigmentary disorders as well as an active ingredient in cosmetics to increase whitening efficacy. © 2017 S. Karger AG, Basel.

  11. Relationship of cumulative low-level dose of ionizing radiation on human eye lens and occurrence of cataract

    International Nuclear Information System (INIS)

    Deolalikar, Raghavendra

    2015-01-01

    International Commission on Radiological Protection (ICRP), issued a statement on Tissue Reaction, lowering the equivalent dose limit for eye lens for occupational exposure to 20 mSv per year. With a view to determine presence of any relationship between the cumulative low-level occupational radiation dose to the eye lens and occurrence of cataract, departmental records of the annual medical examination of employees of Narora Atomic Power Plant were examined along with the NAPS eye camps and surgical records of the employees. Analysis of the data showed no demonstrable definite relationship between the two. The analysis of the data and the observations are discussed in this paper. (author)

  12. Low level ionizing radiation and human mortality: multi-regional epidemiological studies

    International Nuclear Information System (INIS)

    Hickey, R.J.; Bowers, E.J.; Spence, D.E.; Zemel, B.S.; Clelland, A.B.; Clelland, R.C.

    1981-01-01

    Analyses of relationships involving environmental chemicals, background radiation, and mortality rates for diseases of the heart and several cancer categories are presented. Bivariate correlation coefficients between radiation and mortality rate were significantly negative for cancer of the lung and respiratory organs, cancer of the buccal cavity and pharynx, cancer of the digestive organs and peritoneum, total cancer and diseases of the heart. Only the correlation coefficient between background radiation and leukemia-aleukemia was positive, and that not significantly positive. Initial multivariate statistical studies support the bivariate results in that all significant regression terms that represent background radiation have been negative. Background radiation level was not a significant predictor for leukemia-aleukemia mortality rate when examined without regard to age. This preliminary work suggests that any health effects of background radiation on the diseases studied do not exceed in magnitude those of environmental chemicals. It also suggests that models implying important long-term deleterious effects of low levels of ionizing radiation on humans may be invalid. (author)

  13. Diversity, variation and fairness: Equivalence in national level language assessments

    Directory of Open Access Journals (Sweden)

    Albert Weideman

    2017-03-01

    Full Text Available The post-1994 South African constitution proudly affirms the language diversity of the country, as do subsequent laws, while ministerial policies, both at further and higher education level, similarly promote the use of all 11 official languages in education. However, such recognition of diversity presents several challenges to accommodate potential variation. In language education at secondary school, which is nationally assessed, the variety being promoted immediately raises issues of fairness and equivalence. The final high-stakes examination of learners’ ability in home language at the exit level of their pre-tertiary education is currently contentious in South Africa. It is known, for example, that in certain indigenous languages, the exit level assessments barely discriminate among learners with different abilities, while in other languages they do. For that reason, the Council for Quality Assurance in General and Further Education, Umalusi, has commissioned several reports to attempt to understand the nature of the problem. This article will deal with a discussion of a fourth attempt by Umalusi to solve the problem. That attempt, undertaken by a consortium of four universities, has already delivered six interim reports to this statutory body, and the article will consider some of their content and methodology. In their reconceptualisation of the problem, the applied linguists involved first sought to identify the theoretical roots of the current curriculum in order to articulate more sharply the construct being assessed. That provides the basis for a theoretical justification of the several solutions being proposed, as well as for the preliminary designs of modifications to current, and the introduction of new assessments. The impact of equivalence of measurement as a design requirement will be specifically discussed, with reference to the empirical analyses of results of a number of pilots of equivalent tests in different languages.

  14. Interactive short-term effects of equivalent temperature and air pollution on human mortality in Berlin and Lisbon

    International Nuclear Information System (INIS)

    Burkart, Katrin; Canário, Paulo; Breitner, Susanne; Schneider, Alexandra; Scherber, Katharina; Andrade, Henrique; Alcoforado, Maria João; Endlicher, Wilfried

    2013-01-01

    There is substantial evidence that both temperature and air pollution are predictors of mortality. Thus far, few studies have focused on the potential interactive effects between the thermal environment and different measures of air pollution. Such interactions, however, are biologically plausible, as (extreme) temperature or increased air pollution might make individuals more susceptible to the effects of each respective predictor. This study investigated the interactive effects between equivalent temperature and air pollution (ozone and particulate matter) in Berlin (Germany) and Lisbon (Portugal) using different types of Poisson regression models. The findings suggest that interactive effects exist between air pollutants and equivalent temperature. Bivariate response surface models and generalised additive models (GAMs) including interaction terms showed an increased risk of mortality during periods of elevated equivalent temperatures and air pollution. Cold effects were mostly unaffected by air pollution. The study underscores the importance of air pollution control in mitigating heat effects. -- Highlights: • Interactive effects between air pollution and equivalent temperature result in augmented excess mortality. • High levels of ozone and particulate matter increase adverse heat effects on human mortality. • Cold effects are mostly unaffected by air pollution. • Findings underscore the importance of air pollution control in mitigating heat-related mortality. -- Interactive effects between air pollution and elevated (equivalent) temperatures underscore the importance of air pollution control in mitigating the adverse effects of heat

  15. Determination of the optical properties of melanin-pigmented human skin equivalents using terahertz time-domain spectroscopy

    Science.gov (United States)

    Lipscomb, Dawn; Echchgadda, Ibtissam; Peralta, Xomalin G.; Wilmink, Gerald J.

    2013-02-01

    Terahertz time-domain spectroscopy (THz-TDS) methods have been utilized in previous studies in order to characterize the optical properties of skin and its primary constituents (i.e., water, collagen, and keratin). However, similar experiments have not yet been performed to investigate whether melanocytes and the melanin pigment that they synthesize contribute to skin's optical properties. In this study, we used THz-TDS methods operating in transmission geometry to measure the optical properties of in vitro human skin equivalents with or without normal human melanocytes. Skin equivalents were cultured for three weeks to promote gradual melanogenesis, and THz time domain data were collected at various time intervals. Frequency-domain analysis techniques were performed to determine the index of refraction (n) and absorption coefficient (μa) for each skin sample over the frequency range of 0.1-2.0 THz. We found that for all samples as frequency increased, n decreased exponentially and the μa increased linearly. Additionally, we observed that skin samples with higher levels of melanin exhibited greater n and μa values than the non-pigmented samples. Our results indicate that melanocytes and the degree of melanin pigmentation contribute in an appreciable manner to the skin's optical properties. Future studies will be performed to examine whether these contributions are observed in human skin in vivo.

  16. An assessment of the radiological impact of human intrusion at the UK Low Level Waste Repository (LLWR) - 59356

    International Nuclear Information System (INIS)

    Hicks, Tim; Baldwin, Tamara; Cummings, Richard; Sumerling, Trevor

    2012-01-01

    The UK Low Level Waste Repository Ltd submitted an Environmental Safety Case for the disposal of low-level waste (LLW) to the Environment Agency on the 1 May 2011. The Environmental Safety Case (ESC) presents a complete case for the environmental safety of the Low Level Waste Repository (LLWR) both during operations and in the long term (Cummings et al, in these proceedings). This includes an assessment of the long-term radiological safety of the facility, including an assessment of the potential consequences of human intrusion at the site. The human intrusion assessment is based on a cautiously realistic approach in defining intrusion cases and parameter values. A range of possible human intrusion events was considered based on present-day technologies and credible future uses of the site. This process resulted in the identification of geotechnical investigations, a housing development and a smallholding as requiring quantitative assessment. A particular feature of the site is that, because of its proximity to the coast and in view of expected global sea-level rise, it is vulnerable to coastal erosion. During such erosion, wastes and engineered barrier materials will be exposed, and could become targets for investigation or recovery. Therefore, human intrusion events have been included that are associated with such activities. A radiological assessment model has been developed to analyse the impacts of potential human intrusion at the site. A key feature of the model is the representation of the spatial layout of the disposal site, including the engineered cap design and the large-scale spatial heterogeneity of radionuclide concentrations within the repository. The model has been used to calculate the radiation dose to intruders and to others following intrusion at different times and at different locations across the site, for the each of the selected intrusion events, considering all relevant exposure modes. Potential doses due to radon and its daughters in

  17. WIPP WAC Equivalence Support Measurements for Low-Level Sludge Waste at Los Alamos National Laboratory - 12242

    Energy Technology Data Exchange (ETDEWEB)

    Gruetzmacher, Kathleen M.; Bustos, Roland M.; Ferran, Scott G.; Gallegos, Lucas E. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Lucero, Randy P. [Pajarito Scientific Corporation, Santa Fe, New Mexico 87507 (United States)

    2012-07-01

    Los Alamos National Laboratory (LANL) uses the Nevada National Security Site (NNSS) as an off-site disposal facility for low-level waste (LLW), including sludge waste. NNSS has issued a position paper that indicates that systems that are not certified by the Carlsbad Field Office (CBFO) for Waste Isolation Pilot Plant (WIPP) disposal of Transuranic (TRU) waste must demonstrate equivalent practices to the CBFO certified systems in order to assign activity concentration values to assayed items without adding in the Total Measurement Uncertainty (TMU) when certifying waste for NNSS disposal. Efforts have been made to meet NNSS requirements to accept sludge waste for disposal at their facility. The LANL LLW Characterization Team uses portable high purity germanium (HPGe) detector systems for the nondestructive assay (NDA) of both debris and sludge LLW. A number of performance studies have been conducted historically by LANL to support the efficacy and quality of assay results generated by the LANL HPGe systems, and, while these detector systems are supported by these performance studies and used with LANL approved procedures and processes, they are not certified by CBFO for TRU waste disposal. Beginning in 2009, the LANL LLW Characterization Team undertook additional NDA measurements of both debris and sludge simulated waste containers to supplement existing studies and procedures to demonstrate full compliance with the NNSS position paper. Where possible, Performance Demonstration Project (PDP) drums were used for the waste matrix and PDP sources were used for the radioactive sources. Sludge drums are an example of a matrix with a uniform distribution of contaminants. When attempting to perform a gamma assay of a sludge drum, it is very important to adequately simulate this uniform distribution of radionuclides in order to accurately model the assay results. This was accomplished by using a spiral radial source tube placement in a sludge drum rather than the standard

  18. Technical advance: Generation of human pDC equivalents from primary monocytes using Flt3-L and their functional validation under hypoxia.

    Science.gov (United States)

    Sekar, Divya; Brüne, Bernhard; Weigert, Andreas

    2010-08-01

    The division of labor between DC subsets is evolutionarily well-defined. mDC are efficient in antigen presentation, whereas pDC act as rheostats of the immune system. They activate NK cells, cause bystander activation of mDC, and interact with T cells to induce tolerance. This ambiguity positions pDC at the center of inflammatory diseases, such as cancer, arthritis, and autoimmune diseases. The ability to generate human mDC ex vivo made it possible to engineer them to suit therapy needs. Unfortunately, a similar, easily accessible system to generate human pDC is not available. We describe a method to generate human pDC equivalents ex vivo, termed mo-pDC from peripheral blood monocytes using Flt3-L. mo-pDC showed a characteristic pDC profile, such as high CD123 and BDCA4, but low CD86 and TLR4 surface expression and a low capacity to induce autologous lymphocyte proliferation and to phagocytose apoptotic debris in comparison with mDC. Interestingly, mo-pDC up-regulated the pDC lineage-determining transcription factor E2-2 as well as expression of BDCA2, which is under the transcriptional control of E2-2 but not its inhibitor ID2, during differentiation. mo-pDC produced high levels of IFN-alpha when pretreated overnight with TNF-alpha. Under hypoxia, E2-2 was down-regulated, and ID2 was induced in mo-pDC, whereas surface expression of MHCI, CD86, and BDCA2 was decreased. Furthermore, mo-pDC produced high levels of inflammatory cytokines when differentiated under hypoxia compared with normoxia. Hence, mo-pDC can be used to study differentiation and functions of human pDC under microenvironmental stimuli.

  19. Development of an experimental method for the determination of the dose equivalent indices for low - and medium energy X- and gamma rays

    International Nuclear Information System (INIS)

    Silva Estrada, J.J. da.

    1980-01-01

    An experimental method was developed to measure Dose Equivalent Indices for low and medium energy X-rays. A sphere was constructed to simulate the human body in accordance with ICRU Report 19 but using plexiglass instead of tissue equivalent material of density 1 g.cm -3 . Experimentally it was demonstrated that for the purpose of applied radiation protection both materials are equivalent in spite of a 18% higher density of plexiglass. CaF 2 :Mn and LiF:Mg might be utilized to determine the absorbed dose distribution within the sphere. Measurements indicate that the effective energy can be determined with an accuracy better than 15% for the energy range under consideration. Depth dose curves measured with ionization chamber compared with those of LiF:Mg showed an agreement better than 12% and in the case of CaF 2 :Mn better than 11% for all irradiation conditions used. Conversion factors in units rad R -1 measured with TLD and compared with those obtained from the literature based upon Monte Carlo calculation showed an agreement better than 23% for CaF 2 :Mn and 19% for LiF:Mg. It is concluded from these experiments that the system plexiglass sphere-TLD dosimeters might be used to measure Dose Equivalent Indices for low and medium energy photons. (Author) [pt

  20. Melanin Transfer in Human 3D Skin Equivalents Generated Exclusively from Induced Pluripotent Stem Cells.

    Science.gov (United States)

    Gledhill, Karl; Guo, Zongyou; Umegaki-Arao, Noriko; Higgins, Claire A; Itoh, Munenari; Christiano, Angela M

    2015-01-01

    The current utility of 3D skin equivalents is limited by the fact that existing models fail to recapitulate the cellular complexity of human skin. They often contain few cell types and no appendages, in part because many cells found in the skin are difficult to isolate from intact tissue and cannot be expanded in culture. Induced pluripotent stem cells (iPSCs) present an avenue by which we can overcome this issue due to their ability to be differentiated into multiple cell types in the body and their unlimited growth potential. We previously reported generation of the first human 3D skin equivalents from iPSC-derived fibroblasts and iPSC-derived keratinocytes, demonstrating that iPSCs can provide a foundation for modeling a complex human organ such as skin. Here, we have increased the complexity of this model by including additional iPSC-derived melanocytes. Epidermal melanocytes, which are largely responsible for skin pigmentation, represent the second most numerous cell type found in normal human epidermis and as such represent a logical next addition. We report efficient melanin production from iPSC-derived melanocytes and transfer within an entirely iPSC-derived epidermal-melanin unit and generation of the first functional human 3D skin equivalents made from iPSC-derived fibroblasts, keratinocytes and melanocytes.

  1. Melanin Transfer in Human 3D Skin Equivalents Generated Exclusively from Induced Pluripotent Stem Cells.

    Directory of Open Access Journals (Sweden)

    Karl Gledhill

    Full Text Available The current utility of 3D skin equivalents is limited by the fact that existing models fail to recapitulate the cellular complexity of human skin. They often contain few cell types and no appendages, in part because many cells found in the skin are difficult to isolate from intact tissue and cannot be expanded in culture. Induced pluripotent stem cells (iPSCs present an avenue by which we can overcome this issue due to their ability to be differentiated into multiple cell types in the body and their unlimited growth potential. We previously reported generation of the first human 3D skin equivalents from iPSC-derived fibroblasts and iPSC-derived keratinocytes, demonstrating that iPSCs can provide a foundation for modeling a complex human organ such as skin. Here, we have increased the complexity of this model by including additional iPSC-derived melanocytes. Epidermal melanocytes, which are largely responsible for skin pigmentation, represent the second most numerous cell type found in normal human epidermis and as such represent a logical next addition. We report efficient melanin production from iPSC-derived melanocytes and transfer within an entirely iPSC-derived epidermal-melanin unit and generation of the first functional human 3D skin equivalents made from iPSC-derived fibroblasts, keratinocytes and melanocytes.

  2. Enhanced constitutive invasion activity in human nontumorigenic keratinocytes exposed to a low level of barium for a long time.

    Science.gov (United States)

    Thang, Nguyen D; Yajima, Ichiro; Ohnuma, Shoko; Ohgami, Nobutaka; Kumasaka, Mayuko Y; Ichihara, Gaku; Kato, Masashi

    2015-02-01

    We have recently demonstrated that exposure to barium for a short time (≤4 days) and at a low level (5 µM = 687 µg/L) promotes invasion of human nontumorigenic HaCaT cells, which have characteristics similar to those of normal keratinocytes, suggesting that exposure to barium for a short time enhances malignant characteristics. Here we examined the effect of exposure to low level of barium for a long time, a condition mimicking the exposure to barium through well water, on malignant characteristics of HaCaT keratinocytes. Constitutive invasion activity, focal adhesion kinase (FAK) protein expression and activity, and matrix metalloproteinase 14 (MMP14) protein expression in primary cultured normal human epidermal keratinocytes, HaCaT keratinocytes, and HSC5 and A431 human squamous cell carcinoma cells were augmented following an increase in malignancy grade of the cells. Constitutive invasion activity, FAK phosphorylation, and MMP14 expression levels of HaCaT keratinocytes after treatment with 5 µM barium for 4 months were significantly higher than those of control untreated HaCaT keratinocytes. Taken together, our results suggest that exposure to a low level of barium for a long time enhances constitutive malignant characteristics of HaCaT keratinocytes via regulatory molecules (FAK and MMP14) for invasion. © 2013 Wiley Periodicals, Inc.

  3. Low-dose caffeine physical dependence in humans.

    Science.gov (United States)

    Griffiths, R R; Evans, S M; Heishman, S J; Preston, K L; Sannerud, C A; Wolf, B; Woodson, P P

    1990-12-01

    This study investigated the effects of terminating low dose levels of caffeine (100 mg/day) in 7 normal humans. Substitution of placebo capsules for caffeine capsules occurred under double-blind conditions while subjects rated various dimensions of their mood and behavior. In the first phase of the study, substitution of placebo for 12 consecutive days resulted in an orderly withdrawal syndrome in 4 subjects which peaked on days 1 or 2 and progressively decreased toward prewithdrawal levels over about 1 week. Data from the remaining three subjects provided no evidence of withdrawal. In the second phase of the study, the generality of the withdrawal effect was examined by repeatedly substituting placebo for 100 mg/day of caffeine for 1-day periods separated by an average of 9 days. Despite differences within and across subjects with respect to the presence, nature and magnitude of symptoms, each of the seven subjects demonstrated a statistically significant withdrawal effect. Although the phenomenon of caffeine withdrawal has been described previously, the present report documents that the incidence of caffeine withdrawal is higher (100% of subjects), the daily dose level at which withdrawal occurs is lower (roughly equivalent to the amount of caffeine in a single cup of strong brewed coffee or 3 cans of caffeinated soft drink) and the range of symptoms experienced is broader (including headache, fatigue and other dysphoric mood changes, muscle pain/stiffness, flu-like feelings, nausea/vomiting and craving for caffeine) than heretofore recognized.

  4. An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity and Extraterrestrial Fire-Safety Applications

    Science.gov (United States)

    Olson, S. L.; Beeson, H.; Haas, J. P.

    2003-01-01

    The objective of this project is to modify the standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. This apparatus will allow us to conduct normal gravity experiments that accurately and quantitatively evaluate a material's flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire configuration that provides a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by a flame in a spacecraft or extraterrestrial gravity level. Prototype unit testing results are presented in this paper. Ignition delay times and regression rates for PMMA are presented over a range of radiant heat flux levels and equivalent stretch rates which demonstrate the ability of ELSA to simulate key features of microgravity and extraterrestrial fire behavior.

  5. Equivalent threshold sound pressure levels (ETSPL) for Interacoustics DD 45 supra-aural audiometric earphones

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2010-01-01

    This paper describes the determination and results of pure tone Equivalent Threshold Sound Pressure Levels for the Interacoustics DD45 audiometric earphone equipped with standard Model 51 cushions. The size and shape of the DD45 transducer resembles the classical Telephonics TDH 39 earphone. Pure...... tone hearing threshold measurements were performed for both ears of 29 test subjects. All audiometric frequencies from 125 Hz to 8 kHz were used. The data are intended for inclusion in future standardized Reference Equivalent Threshold Sound Pressure Levels. The results show that the DD45 may be a good...

  6. Safety assessment on the human intrusion scenarios of near surface disposal facility for low and very low level radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Wook; Park, Jin Baek [Korea Radioactive Waste Agency, Daejeon (Korea, Republic of); Park, Sang Ho [Chungnam National University, Daejeon (Korea, Republic of)

    2016-03-15

    The second-stage near surface disposal facility for low and very low level radioactive waste's permanent disposal is to be built. During the institutional control period, the inadvertent intrusion of the general public is limited. But after the institutional control period, the access to the general public is not restricted. Therefore human who has purpose of residence and resource exploration can intrude the disposal facility. In this case, radioactive effects to the intruder should be limited within regulatory dose limits. This study conducted the safety assessment of human intrusion on the second-stage surface disposal facility through drilling and post drilling scenario. Results of drilling and post drilling scenario were satisfied with regulatory dose limits. The result showed that post-drilling scenario was more significant than drilling scenario. According to the human intrusion time and behavior after the closure of the facility, dominant radionuclide contributing to the intruder was different. Sensitivity analyses on the parameters about the human behavior were also satisfied with regulatory dose limits. Especially, manual redistribution factor was the most sensitive parameter on exposure dose. A loading plan of spent filter waste and dry active waste was more effective than a loading plan of spent filter waste and other wastes for the radiological point of view. These results can be expected to provide both robustness and defense in depth for the development of safety case further.

  7. On the calibration of photon dosemeters in the equivalent dose units

    International Nuclear Information System (INIS)

    Bregadze, Yu.I.; Isaev, B.M.; Maslyaev, P.F.

    1980-01-01

    General aspects of transition from exposure dose of photo radiation to equivalent one are considered. By determination the equivalent dose is a function of point location in an irradiated object, that is why it is necessary to know equivalent dose distribution in the human body for uniform description of the risk degree. The international electrotechnical comission recommends to measure equivalent doses at 7 and 800 mg/cm 2 depths in a tissue-equivalent ball with 30 cm diameter, calling them skin equivalent dose and depth equivalent dose, respectively, and to compare them with the permissible 500 mZ and 50 mZ a year, respectively. Practical transition to using equivalent dose for evaluation of radiation danger of being in photon radiation field of low energy should include measures on regraduating already produced dose meters, graduating the dose meters under production and developing the system of their metrologic supply [ru

  8. Overview of the hazards of low-level exposure to radiation

    International Nuclear Information System (INIS)

    Ritenour, E.R.

    1984-01-01

    In this chapter the authors are concerned with low-level radiation, doses of ionizing radiations that are ten to thousands of times smaller than those required to contract ARS. Low-level radiation may be defined as an absorbed dose of 10 rem or less delivered over a short period of time. A larger dose delivered over a long period of time, for instance, 50 rem in 10 years, may also be considered low level. The definition is purposely loose so as to cover a wide variety of sources of radiation exposure, such as natural background (100 mrem/year) occupational exposures (<5 rem/year), and medical applications, such as diagnostic radiography (<1 rem). Low-level radiation exposure does not produce ARS. The health effects that may be of concern in regard to low-level radiation are its long-term sequelae. Studies of survivors of high-level radiation exposure (both human and laboratory animals) have indicated that there are three health effects that should be examined at low levels of exposure: induction of cancer, birth abnormalities (from irradiation in utero), and genetic effects. No other long-term effects of low-level exposure have been conclusively demonstrated in animals or humans

  9. [Equivalent continuous noise level in neonatal intensive care unit associated to burnout syndrome].

    Science.gov (United States)

    Garrido Galindo, A P; Camargo Caicedo, Y; Vélez-Pereira, A M

    2015-01-01

    Noise levels in neonatal intensive care units allow the appearance of symptoms associated with burnout such as stress, irritability, fatigue and emotional instability on health care personnel. The aim of this study was to evaluate the equivalent continuous noise levels in the neonatal intensive care unit and compare the results with noise levels associated with the occurrence of burnout syndrome on the care team. Continuous sampling was conducted for 20 days using a type I sound level meter on the unit. The maximum, the ninetieth percentile and the equivalent continuous noise level (Leq) values were recorded. Noise level is reported in the range of 51.4-77.6 decibels A (dBA) with an average of 64 dBA, 100.6 dBA maximum, and average background noise from 57.9 dBA. Noise levels exceed the standards suggested for neonatal intensive care units, are close to maximum values referred for noise exposure in the occupational standards and to noise levels associated with the onset of burnout; thus allowing to infer the probability of occurrence of high levels of noise present in the unit on the development of burnout in caregivers. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  10. Photomultiplier tubes for Low Level Cerenkov Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Strindehag, O

    1965-03-15

    Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a {beta}-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10{sup -12} input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10{sup -12} to 10{sup -9} input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses.

  11. Photomultiplier tubes for Low Level Cerenkov Detectors

    International Nuclear Information System (INIS)

    Strindehag, O.

    1965-03-01

    Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a β-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10 -12 input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10 -12 to 10 -9 input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses

  12. Hanford low-level tank waste interim performance assessment

    International Nuclear Information System (INIS)

    Mann, F.M.

    1997-01-01

    The Hanford Low-Level Tank Waste Interim Performance Assessment examines the long-term environmental and human health effects associated with the disposal of the low-level fraction of the Hanford single and double-shell tank waste in the Hanford Site 200 East Area. This report was prepared as a good management practice to provide needed information about the relationship between the disposal system design and performance early in the disposal system project cycle. The calculations in this performance assessment show that the disposal of the low-level fraction can meet environmental and health performance objectives

  13. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1992-01-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modelling techniques and a knowledge of the incident radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well chosen measurements are required to confirm the theoretical models. Neutron doses and dose equivalents were measured in a RANDO phantom at specific locations using thermoluminescence dosemeters, etched track dosemeters, and a 1.27 cm (1/2 in) tissue-equivalent proportional counter. The phantom was exposed to a bare and a D 2 O-moderated 252 Cf neutron source at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and to calculate the organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared with the calculations. (author)

  14. Temporary threshold shifts from exposures to equal equivalent continuous A-weighted sound pressure level

    DEFF Research Database (Denmark)

    Ordoñez, Rodrigo Pizarro; Hammershøi, Dorte

    2014-01-01

    the assumptions made using the A-weighting curve for the assessment of hearing damage. By modifying exposure ratings to compensate for the build-up of energy at mid and high-frequencies (above 1 kHz) due to the presence of the listener in the sound field and for the levels below an effect threshold that does...... not induce changes in hearing (equivalent quiet levels), ratings of the sound exposure that reflect the observed temporary changes in auditory function can be obtained.......According to existing methods for the assessment of hearing damage, signals with the same A-weighted equivalent level should pose the same hazard to the auditory system. As a measure of hazard, it is assumed that Temporary Thresholds Shifts (TTS) reflect the onset of alterations to the hearing...

  15. Acids with an equivalent taste lead to different erosion of human dental enamel.

    Science.gov (United States)

    Beyer, Markus; Reichert, Jörg; Bossert, Jörg; Sigusch, Bernd W; Watts, David C; Jandt, Klaus D

    2011-10-01

    The consumption of acidic soft drinks may lead to demineralization and softening of human dental enamel, known as dental erosion. The aims of this in vitro study were to determine: (i) if different acids with a similar sensorial acidic taste lead to different hardness loss of enamel and (ii) if the fruit acids tartaric, malic, lactic or ascorbic acid lead to less hardness loss of enamel than citric or phosphoric acid when their concentration in solution is based on an equivalent sensorial acidic taste. Enamel samples of non-erupted human third molars were treated with acidic solutions of tartaric (TA), malic (MA), lactic (LA), ascorbic (AA), phosphoric (PA) and citric (CA) acids with a concentration that gave an equivalent sensorial acidic taste. The acidic solutions were characterized by pH value and titratable acidity. Atomic force microscopy (AFM) based nanoindentation was used to study the nano mechanical properties and scanning electron microscopy (SEM) was used to study the morphology of the treated enamel samples and the untreated control areas, respectively. The investigated acids fell into two groups. The nano hardnesses of MA, TA and CA treated enamel samples (group I) were statistically significantly greater (penamel samples (group II). Within each group the nano hardness was not statistically significantly different (p>0.05). The SEM micrographs showed different etch prism morphologies depending on the acid used. In vitro, the acids investigated led to different erosion effects on human dental enamel, despite their equivalent sensorial acidic taste. This has not been reported previously. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  16. Understanding low-level radioactive waste. National Low-Level Radioactive Waste Management Program

    International Nuclear Information System (INIS)

    1983-10-01

    Chapters are devoted to: background and policymaking for low-level waste management; commercial low-level waste generation; Department of Energy low-level waste generation; low-level waste treatment; packaging and transportation; commercial low-level waste disposal; Department of Energy low-level waste disposal; Department of Energy low-level waste management program; and laws and regulations

  17. The effect of equivalence scales on poverty at Oblast level in Ukraine

    Directory of Open Access Journals (Sweden)

    Gianni Betti

    2014-06-01

    Full Text Available This paper aims at properly measuring and evaluating the impact of equivalence scales on poverty and inequality at both national and regional (Oblast level in Ukraine. A new equivalence scale set is proposed and estimated on the basis of the UHLSC data; for some regions the precision of the estimate results as not being sufficient due to small sub-sample sizes. A variant of EBLUP small area estimation technique is proposed and implemented to estimate poverty measures properly and to reduce standard errors of such estimates; the variant concerned is based on a ratio approach: in this way the effect of the difficult-to-qualify institutional and historical factors, common to the country and its regions, is abstracted.

  18. Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose.

    Science.gov (United States)

    Manimaran, S

    2007-06-01

    The aim of this study was to compare the biological equivalent of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy in terms of the more recent linear quadratic (LQ) model, which leads to theoretical estimation of biological equivalence. One of the key features of the LQ model is that it allows a more systematic radiobiological comparison between different types of treatment because the main parameters alpha/beta and micro are tissue-specific. Such comparisons also allow assessment of the likely change in the therapeutic ratio when switching between LDR and HDR treatments. The main application of LQ methodology, which focuses on by increasing the availability of remote afterloading units, has been to design fractionated HDR treatments that can replace existing LDR techniques. In this study, with LDR treatments (39 Gy in 48 h) equivalent to 11 fractions of HDR irradiation at the experimental level, there are increasing reports of reproducible animal models that may be used to investigate the biological basis of brachytherapy and to help confirm theoretical predictions. This is a timely development owing to the nonavailability of sufficient retrospective patient data analysis. It appears that HDR brachytherapy is likely to be a viable alternative to LDR only if it is delivered without a prohibitively large number of fractions (e.g., fewer than 11). With increased scientific understanding and technological capability, the prospect of a dose equivalent to HDR brachytherapy will allow greater utilization of the concepts discussed in this article.

  19. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1991-10-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modeling techniques and a knowledge of the radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well-chosen measurements are required to confirm the theoretical models. Neutron measurements were performed in a RANDO phantom using thermoluminescent dosemeters, track etch dosemeters, and a 1/2-in. (1.27-cm) tissue equivalent proportional counter in order to estimate neutron doses and dose equivalents within the phantom at specific locations. The phantom was exposed to bare and D 2 O-moderated 252 Cf neutrons at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and calculate organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared to the calculations. 8 refs., 3 figs., 3 tabs

  20. Construction of a human corneal stromal equivalent with non-transfected human corneal stromal cells and acellular porcine corneal stromata.

    Science.gov (United States)

    Diao, Jin-Mei; Pang, Xin; Qiu, Yue; Miao, Ying; Yu, Miao-Miao; Fan, Ting-Jun

    2015-03-01

    A tissue-engineered human corneal stroma (TE-HCS) has been developed as a promising equivalent to the native corneal stroma for replacement therapy. However, there is still a crucial need to improve the current approaches to render the TE-HCS equivalent more favorable for clinical applications. At the present study, we constructed a TE-HCS by incubating non-transfected human corneal stromal (HCS) cells in an acellular porcine corneal stromata (aPCS) scaffold in 20% fetal bovine serum supplemented DMEM/F12 (1:1) medium at 37 °C with 5% CO2in vitro. After 3 days of incubation, the constructed TE-HCS had a suitable tensile strength for transplantation, and a transparency that is comparable to native cornea. The TE-HCS had a normal histological structure which contained regularly aligned collagen fibers and differentiated HCS cells with positive expression of marker and functional proteins, mimicking a native HCS. After transplantation into rabbit models, the TE-HCS reconstructed normal corneal stroma in vivo and function well in maintaining corneal clarity and thickness, indicating that the completely biological TE-HCS could be used as a HCS equivalent. The constructed TE-HCS has promising potentials in regenerative medicine and treatment of diseases caused by corneal stromal disorders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Tauopathy induced by low level expression of a human brain-derived tau fragment in mice is rescued by phenylbutyrate.

    Science.gov (United States)

    Bondulich, Marie K; Guo, Tong; Meehan, Christopher; Manion, John; Rodriguez Martin, Teresa; Mitchell, Jacqueline C; Hortobagyi, Tibor; Yankova, Natalia; Stygelbout, Virginie; Brion, Jean-Pierre; Noble, Wendy; Hanger, Diane P

    2016-08-01

    Human neurodegenerative tauopathies exhibit pathological tau aggregates in the brain along with diverse clinical features including cognitive and motor dysfunction. Post-translational modifications including phosphorylation, ubiquitination and truncation, are characteristic features of tau present in the brain in human tauopathy. We have previously reported an N-terminally truncated form of tau in human brain that is associated with the development of tauopathy and is highly phosphorylated. We have generated a new mouse model of tauopathy in which this human brain-derived, 35 kDa tau fragment (Tau35) is expressed in the absence of any mutation and under the control of the human tau promoter. Most existing mouse models of tauopathy overexpress mutant tau at levels that do not occur in human neurodegenerative disease, whereas Tau35 transgene expression is equivalent to less than 10% of that of endogenous mouse tau. Tau35 mice recapitulate key features of human tauopathies, including aggregated and abnormally phosphorylated tau, progressive cognitive and motor deficits, autophagic/lysosomal dysfunction, loss of synaptic protein, and reduced life-span. Importantly, we found that sodium 4-phenylbutyrate (Buphenyl®), a drug used to treat urea cycle disorders and currently in clinical trials for a range of neurodegenerative diseases, reverses the observed abnormalities in tau and autophagy, behavioural deficits, and loss of synapsin 1 in Tau35 mice. Our results show for the first time that, unlike other tau transgenic mouse models, minimal expression of a human disease-associated tau fragment in Tau35 mice causes a profound and progressive tauopathy and cognitive changes, which are rescued by pharmacological intervention using a clinically approved drug. These novel Tau35 mice therefore represent a highly disease-relevant animal model in which to investigate molecular mechanisms and to develop novel treatments for human tauopathies. © The Author (2016). Published by

  2. Tauopathy induced by low level expression of a human brain-derived tau fragment in mice is rescued by phenylbutyrate

    Science.gov (United States)

    Bondulich, Marie K.; Guo, Tong; Meehan, Christopher; Manion, John; Rodriguez Martin, Teresa; Mitchell, Jacqueline C.; Hortobagyi, Tibor; Yankova, Natalia; Stygelbout, Virginie; Brion, Jean-Pierre; Noble, Wendy

    2016-01-01

    Abstract Human neurodegenerative tauopathies exhibit pathological tau aggregates in the brain along with diverse clinical features including cognitive and motor dysfunction. Post-translational modifications including phosphorylation, ubiquitination and truncation, are characteristic features of tau present in the brain in human tauopathy. We have previously reported an N-terminally truncated form of tau in human brain that is associated with the development of tauopathy and is highly phosphorylated. We have generated a new mouse model of tauopathy in which this human brain-derived, 35 kDa tau fragment (Tau35) is expressed in the absence of any mutation and under the control of the human tau promoter. Most existing mouse models of tauopathy overexpress mutant tau at levels that do not occur in human neurodegenerative disease, whereas Tau35 transgene expression is equivalent to less than 10% of that of endogenous mouse tau. Tau35 mice recapitulate key features of human tauopathies, including aggregated and abnormally phosphorylated tau, progressive cognitive and motor deficits, autophagic/lysosomal dysfunction, loss of synaptic protein, and reduced life-span. Importantly, we found that sodium 4-phenylbutyrate (Buphenyl®), a drug used to treat urea cycle disorders and currently in clinical trials for a range of neurodegenerative diseases, reverses the observed abnormalities in tau and autophagy, behavioural deficits, and loss of synapsin 1 in Tau35 mice. Our results show for the first time that, unlike other tau transgenic mouse models, minimal expression of a human disease-associated tau fragment in Tau35 mice causes a profound and progressive tauopathy and cognitive changes, which are rescued by pharmacological intervention using a clinically approved drug. These novel Tau35 mice therefore represent a highly disease-relevant animal model in which to investigate molecular mechanisms and to develop novel treatments for human tauopathies. PMID:27297240

  3. Resonant Rectifier ICs for Piezoelectric Energy Harvesting Using Low-Voltage Drop Diode Equivalents.

    Science.gov (United States)

    Din, Amad Ud; Chandrathna, Seneke Chamith; Lee, Jong-Wook

    2017-04-19

    Herein, we present the design technique of a resonant rectifier for piezoelectric (PE) energy harvesting. We propose two diode equivalents to reduce the voltage drop in the rectifier operation, a minuscule-drop-diode equivalent (MDDE) and a low-drop-diode equivalent (LDDE). The diode equivalents are embedded in resonant rectifier integrated circuits (ICs), which use symmetric bias-flip to reduce the power used for charging and discharging the internal capacitance of a PE transducer. The self-startup function is supported by synchronously generating control pulses for the bias-flip from the PE transducer. Two resonant rectifier ICs, using both MDDE and LDDE, are fabricated in a 0.18 μm CMOS process and their performances are characterized under external and self-power conditions. Under the external-power condition, the rectifier using LDDE delivers an output power P OUT of 564 μW and a rectifier output voltage V RECT of 3.36 V with a power transfer efficiency of 68.1%. Under self-power conditions, the rectifier using MDDE delivers a P OUT of 288 μW and a V RECT of 2.4 V with a corresponding efficiency of 78.4%. Using the proposed bias-flip technique, the power extraction capability of the proposed rectifier is 5.9 and 3.0 times higher than that of a conventional full-bridge rectifier.

  4. Resonant Rectifier ICs for Piezoelectric Energy Harvesting Using Low-Voltage Drop Diode Equivalents

    Science.gov (United States)

    Din, Amad Ud; Chandrathna, Seneke Chamith; Lee, Jong-Wook

    2017-01-01

    Herein, we present the design technique of a resonant rectifier for piezoelectric (PE) energy harvesting. We propose two diode equivalents to reduce the voltage drop in the rectifier operation, a minuscule-drop-diode equivalent (MDDE) and a low-drop-diode equivalent (LDDE). The diode equivalents are embedded in resonant rectifier integrated circuits (ICs), which use symmetric bias-flip to reduce the power used for charging and discharging the internal capacitance of a PE transducer. The self-startup function is supported by synchronously generating control pulses for the bias-flip from the PE transducer. Two resonant rectifier ICs, using both MDDE and LDDE, are fabricated in a 0.18 μm CMOS process and their performances are characterized under external and self-power conditions. Under the external-power condition, the rectifier using LDDE delivers an output power POUT of 564 μW and a rectifier output voltage VRECT of 3.36 V with a power transfer efficiency of 68.1%. Under self-power conditions, the rectifier using MDDE delivers a POUT of 288 μW and a VRECT of 2.4 V with a corresponding efficiency of 78.4%. Using the proposed bias-flip technique, the power extraction capability of the proposed rectifier is 5.9 and 3.0 times higher than that of a conventional full-bridge rectifier. PMID:28422085

  5. Tribological behaviour of skin equivalents and ex-vivo human skin against the material components of artificial turf in sliding

    NARCIS (Netherlands)

    Morales Hurtado, Marina; Peppelman, P.; Zeng, Xiangqiong; van Erp, P.E.J.; van der Heide, Emile

    2016-01-01

    This research aims to analyse the interaction of three artificial skin equivalents and human skin against the main material components of artificial turf. The tribological performance of Lorica, Silicone Skin L7350 and a recently developed Epidermal Skin Equivalent (ESE) were studied and compared to

  6. Low-level radiation risks in people

    International Nuclear Information System (INIS)

    Goloman, M.; Filjushkin, V. lgor

    1993-01-01

    Using the limited human data plus the relationships derived from the laboratory, a leukemia risk model has been developed as well as a suggested model for other cancers in people exposed to low levels of radiation. Theoretical experimental and epidemiological evidence will be presented in an integrated stochastic model for projection of radiation-induced cancer risks

  7. Proposal of Design Formulae for Equivalent Elasticity of Masonry Structures Made with Bricks of Low Modulus

    Directory of Open Access Journals (Sweden)

    Muhammad Ridwan

    2017-01-01

    Full Text Available Bricks of low elastic modulus are occasionally used in some developing countries, such as Indonesia and India. Most of the previous research efforts focused on masonry structures built with bricks of considerably high elastic modulus. The objective of this study is to quantify the equivalent elastic modulus of lower-stiffness masonry structures, when the mortar has a higher modulus of elasticity than the bricks, by employing finite element (FE simulations and adopting the homogenization technique. The reported numerical simulations adopted the two-dimensional representative volume elements (RVEs using quadrilateral elements with four nodes. The equivalent elastic moduli of composite elements with various bricks and mortar were quantified. The numerically estimated equivalent elastic moduli from the FE simulations were verified using previously established test data. Hence, a new simplified formula for the calculation of the equivalent modulus of elasticity of such masonry structures is proposed in the present study.

  8. The effects of low level laser irradiation on proliferation of human dental pulp: a narrative review.

    Science.gov (United States)

    Staffoli, S; Romeo, U; Amorim, R N S; Migliau, G; Palaia, G; Resende, L; Polimeni, A

    2017-01-01

    Mesenchymal stem cells (MSCs) have the capability for self-renewal, proliferation, and differentiation in various types of specialized cells, so they are very important in cellular therapies. MSC from dental pulp are simply obtainable and have high proliferative capability. Among the therapies that can stimulate the proliferation of certain cell types, low-level laser therapy (LLLT) stands out. The target of this study is to perform a literature review to investigate these effects of low-level laser irradiation on proliferation of human dental pulp.The electronic search of scientific papers was conducted in the Lilacs, Scielo, Medline and PubMed databases through scientific articles published in national and international journals in the past 20 years.The results of this review suggest that LLLT may be a useful and important tool for future advances in cell therapy and tissue engineering associated to stem cells. Studies on cell therapy for regenerating dental tissues has already been done, and shows promising results.

  9. Dose of radiation enhancement, using silver nanoparticles in a human tissue equivalent gel dosimeter.

    Science.gov (United States)

    Hassan, Muhammad; Waheed, Muhammad Mohsin; Anjum, Muhammad Naeem

    2016-01-01

    To quantify the radiation dose enhancement in a human tissue-equivalent polymer gel impregnated with silver nanoparticles. The case-control study was conducted at the Bahawalpur Institute of Nuclear Medicine and Oncology, Bahawalpur, Pakistan, in January 2014. Silver nanoparticles used in this study were prepared by wet chemical method. Polymer gel was prepared by known quantity of gelatine, methacrylic acid, ascorbic acid, copper sulphate pentahydrate, hydroquinone and water. Different concentrations of silver nanoparticles were added to the gel during its cooling process. The gel was cooled in six plastic vials of 50ml each. Two vials were used as a control sample while four vials were impregnated with silver nanoparticles. After 22 hours, the vials were irradiated with gamma rays by aCobalt-60 unit. Radiation enhancement was assessed by taking magnetic resonance images of the vials. The images were analysed using Image J software. The dose enhancement factor was 24.17% and 40.49% for 5Gy and 10Gy dose respectively. The dose enhancement factor for the gel impregnated with 0.10mM silver nanoparticles was 32.88% and 51.98% for 5Gy and 10Gy dose respectively. The impregnation of a tissue-equivalent gel with silver nanoparticles resulted in dose enhancement and this effect was magnified up to a certain level with the increase in concentration of silver nanoparticles.

  10. Mango (Mangifera indica L.) Polyphenols Ameliorate Functional Constipation Symptoms in Humans Beyond Equivalent Amount of Fiber.

    Science.gov (United States)

    P Venancio, Vinicius; Kim, Hyemee; A Sirven, Maritza; D Tekwe, Carmen; Honvoh, Gilson; T Talcott, Stephen; U Mertens-Talcott, Susanne

    2018-05-07

    Chronic constipation is a common gastrointestinal condition associated with intestinal inflammation and considerably impaired quality of life, affecting about 20% of Americans. Dietary fiber and laxatives aid in its treatment but do not fully address all symptoms, such as intestinal inflammation. Mango (Mangifera indica L.), a fiber- and polyphenol-rich fruit may provide anti-inflammatory effects in constipation. The 4-week consumption of mango fruit (300 g) or the equivalent amount of fiber was investigated in otherwise healthy human volunteers with chronic constipation that were randomly assigned to either group. Blood and fecal samples and digestive wellness questionnaires were collected at the beginning and end of the study. Results show that mango consumption significantly improved constipation status (stool frequency, consistency, and shape) and increased gastrin levels and fecal concentrations of short chain fatty acid (valeric acid) while lowering endotoxin and interleukin 6 concentrations in plasma. In this pilot study, the consumption of mango improves symptoms and associated biomarkers of constipation beyond an equivalent amount of fiber. Larger follow-up studies would need to investigate biomarkers for intestinal inflammation in more detail. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. In search of memory tests equivalent for experiments on animals and humans.

    Science.gov (United States)

    Brodziak, Andrzej; Kołat, Estera; Różyk-Myrta, Alicja

    2014-12-19

    Older people often exhibit memory impairments. Contemporary demographic trends cause aging of the society. In this situation, it is important to conduct clinical trials of drugs and use training methods to improve memory capacity. Development of new memory tests requires experiments on animals and then clinical trials in humans. Therefore, we decided to review the assessment methods and search for tests that evaluate analogous cognitive processes in animals and humans. This review has enabled us to propose 2 pairs of tests of the efficiency of working memory capacity in animals and humans. We propose a basic set of methods for complex clinical trials of drugs and training methods to improve memory, consisting of 2 pairs of tests: 1) the Novel Object Recognition Test - Sternberg Item Recognition Test and 2) the Object-Location Test - Visuospatial Memory Test. We postulate that further investigations of methods that are equivalent in animals experiments and observations performed on humans are necessary.

  12. Testing the equivalence of modern human cranial covariance structure: Implications for bioarchaeological applications.

    Science.gov (United States)

    von Cramon-Taubadel, Noreen; Schroeder, Lauren

    2016-10-01

    Estimation of the variance-covariance (V/CV) structure of fragmentary bioarchaeological populations requires the use of proxy extant V/CV parameters. However, it is currently unclear whether extant human populations exhibit equivalent V/CV structures. Random skewers (RS) and hierarchical analyses of common principal components (CPC) were applied to a modern human cranial dataset. Cranial V/CV similarity was assessed globally for samples of individual populations (jackknifed method) and for pairwise population sample contrasts. The results were examined in light of potential explanatory factors for covariance difference, such as geographic region, among-group distance, and sample size. RS analyses showed that population samples exhibited highly correlated multivariate responses to selection, and that differences in RS results were primarily a consequence of differences in sample size. The CPC method yielded mixed results, depending upon the statistical criterion used to evaluate the hierarchy. The hypothesis-testing (step-up) approach was deemed problematic due to sensitivity to low statistical power and elevated Type I errors. In contrast, the model-fitting (lowest AIC) approach suggested that V/CV matrices were proportional and/or shared a large number of CPCs. Pairwise population sample CPC results were correlated with cranial distance, suggesting that population history explains some of the variability in V/CV structure among groups. The results indicate that patterns of covariance in human craniometric samples are broadly similar but not identical. These findings have important implications for choosing extant covariance matrices to use as proxy V/CV parameters in evolutionary analyses of past populations. © 2016 Wiley Periodicals, Inc.

  13. DEEP code to calculate dose equivalents in human phantom for external photon exposure by Monte Carlo method

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1991-01-01

    The present report describes a computer code DEEP which calculates the organ dose equivalents and the effective dose equivalent for external photon exposure by the Monte Carlo method. MORSE-CG, Monte Carlo radiation transport code, is incorporated into the DEEP code to simulate photon transport phenomena in and around a human body. The code treats an anthropomorphic phantom represented by mathematical formulae and user has a choice for the phantom sex: male, female and unisex. The phantom can wear personal dosimeters on it and user can specify their location and dimension. This document includes instruction and sample problem for the code as well as the general description of dose calculation, human phantom and computer code. (author)

  14. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  15. Safety analysis and inventory control of transuranic and low-level waste in common storage

    International Nuclear Information System (INIS)

    Porten, D.R.; Bonner, A.L.; Joyce, J.P.

    1993-01-01

    This paper describes a methodology developed For the inventory control of low-level waste (LLW) and transuranic (TRU) waste, when both are stored in the same location, and both contribute to an inventory constrained by safety considerations. Development of the method arose from the necessity to make safety analysis calculations for the addition of LLW, in quantities greater than existing inventory limits would allow when stored with TRU waste, in the Hanford Central Waste Complex (CWC)-Ensuring that the dose consequences of credible releases are maintained at low-hazard limits or less, was used to allow greater than Type A quantities of LLW into the CWC. Basically, what happens is the original limited amount of TRU allowed is reduced by some equivalent amount of LLW introduced. The total quantity of TRU, and LLW in excess of Type A quantities, must be administratively maintained via curie equivalency Factors to ensure operation as a low-hazard Facility. The ''equivalency'' between TRU and LLW proposed here is specific only to the CWC, but the methodology can be used for other specific applications, such as TRU and LLW storage or handling facilities where inventory limits must be enforced or where a simplified inventory system is required

  16. Can low-level radiation cause cancer?

    International Nuclear Information System (INIS)

    Trosko, J.E.

    1995-01-01

    Health in a multicellular organism is maintained by homeostatic processes. Disruption of these homeostatic controls at the molecular, biochemical, cellular, and organ systems levels can be brought about by irreversible changes in the genetic material (mutagenesis), cell death (cytotoxicity), or reversible changes in the expression of genes at the transcriptional, translational, or posttranslational levels (epigenesis). While radiation is known to induce DNA damage/mutations, cell, death and epigenetic changes, in addition to cancers that are found in radiation-exposed animals, experimentally, and in humans, epidemiologically, the question is, At low-level exposure, what is the risk that cancers are open-quotes causedclose quotes by the radiation?

  17. LOW-NOISE PAVEMENT AS A WAY OF LIMITATION OF TRAFFIC NOISE LEVEL

    Directory of Open Access Journals (Sweden)

    Władysław Gardziejczyk

    2014-11-01

    Full Text Available Road surface can significantlyreduce the trafficnoise level. Depending on the characteristic of the upper surface layers the differences between the maximum rolling noise levels from passing vehicles to reach values about 10 dB (A. A special group is low-noise pavements characterized by the presence of voids above 15%. Application the porous asphalt layers or asphalt mixture type BBTM affects a significantreduction the width of land surrounded the roads where permissible equivalent sound level is exceeded. Such solutions in some cases can replace acoustic barriers. Road pavements with a higher content of voids require proper maintenance because their acoustic performances are reduced during operation.

  18. Performance objectives for disposal of low-level radioactive wastes on the Oak Ridge Reservation

    Energy Technology Data Exchange (ETDEWEB)

    Kocher, D.C.

    1987-07-01

    This report presents a set of performance objectives for disposal of low-level radioactive wastes in a new facility on the Oak Ridge Reservation. The principal performance objectives include a limit on annual committed effective dose equivalent averaged over a lifetime of 0.25 mSv (25 mrem) for any member of the public beyond the boundary of the disposal facility, and a limit on annual committed effective dose equivalent averaged over a lifetime of 1 mSv (0.1 rem) and a limit on committed effective dose equivalent in any year of 5 mSv (0.5 rem) for any individual who inadvertently intrudes onto the disposal site after loss of active institutional controls. In addition, releases of radioactivity beyond the site boundary shall not result in annual dose equivalents to any number of the public from all sources of exposure that exceed limits established by Federal regulatory authorities and shall be kept as low as reasonably achievable. This report reviews generally applicable radiation protection standards for the public and environmental radiation standards for specific practices that have been developed by national and international authorities and discusses the use of limits on risk rather than dose as performance objectives and consideration of chemical toxicity rather than radiation dose in establishing limits on intakes of uranium. 63 refs., 7 figs., 2 tabs.

  19. Performance objectives for disposal of low-level radioactive wastes on the Oak Ridge Reservation

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1987-07-01

    This report presents a set of performance objectives for disposal of low-level radioactive wastes in a new facility on the Oak Ridge Reservation. The principal performance objectives include a limit on annual committed effective dose equivalent averaged over a lifetime of 0.25 mSv (25 mrem) for any member of the public beyond the boundary of the disposal facility, and a limit on annual committed effective dose equivalent averaged over a lifetime of 1 mSv (0.1 rem) and a limit on committed effective dose equivalent in any year of 5 mSv (0.5 rem) for any individual who inadvertently intrudes onto the disposal site after loss of active institutional controls. In addition, releases of radioactivity beyond the site boundary shall not result in annual dose equivalents to any number of the public from all sources of exposure that exceed limits established by Federal regulatory authorities and shall be kept as low as reasonably achievable. This report reviews generally applicable radiation protection standards for the public and environmental radiation standards for specific practices that have been developed by national and international authorities and discusses the use of limits on risk rather than dose as performance objectives and consideration of chemical toxicity rather than radiation dose in establishing limits on intakes of uranium. 63 refs., 7 figs., 2 tabs

  20. Development of human skin equivalents to unravel the impaired skin barrier in atopic dermatitis skin

    NARCIS (Netherlands)

    Eweje, M.O.

    2016-01-01

    The studies in this thesis describes the barrier defects in Atopic Dermatitis (AD) skin and various techniques to develop AD Human Skin Equivalents (HSEs) which can be used to better understand the role of several factors in the pathogenesis of AD skin. The results described show that Inflammation

  1. EQUIVALENCE VERSUS NON-EQUIVALENCE IN ECONOMIC TRANSLATION

    Directory of Open Access Journals (Sweden)

    Cristina, Chifane

    2012-01-01

    Full Text Available This paper aims at highlighting the fact that “equivalence” represents a concept worth revisiting and detailing upon when tackling the translation process of economic texts both from English into Romanian and from Romanian into English. Far from being exhaustive, our analysis will focus upon the problems arising from the lack of equivalence at the word level. Consequently, relevant examples from the economic field will be provided to account for the following types of non-equivalence at word level: culturespecific concepts; the source language concept is not lexicalised in the target language; the source language word is semantically complex; differences in physical and interpersonal perspective; differences in expressive meaning; differences in form; differences in frequency and purpose of using specific forms and the use of loan words in the source text. Likewise, we shall illustrate a number of translation strategies necessary to deal with the afore-mentioned cases of non-equivalence: translation by a more general word (superordinate; translation by a more neutral/less expressive word; translation by cultural substitution; translation using a loan word or loan word plus explanation; translation by paraphrase using a related word; translation by paraphrase using unrelated words; translation by omission and translation by illustration.

  2. [Influence of human body target's spectral characteristics on visual range of low light level image intensifiers].

    Science.gov (United States)

    Zhang, Jun-Ju; Yang, Wen-Bin; Xu, Hui; Liu, Lei; Tao, Yuan-Yaun

    2013-11-01

    To study the effect of different human target's spectral reflective characteristic on low light level (LLL) image intensifier's distance, based on the spectral characteristics of the night-sky radiation and the spectral reflective coefficients of common clothes, we established a equation of human body target's spectral reflective distribution, and analyzed the spectral reflective characteristics of different human targets wearing the clothes of different color and different material, and from the actual detection equation of LLL image intensifier distance, discussed the detection capability of LLL image intensifier for different human target. The study shows that the effect of different human target's spectral reflective characteristic on LLL image intensifier distance is mainly reflected in the average reflectivity rho(-) and the initial contrast of the target and the background C0. Reflective coefficient and spectral reflection intensity of cotton clothes are higher than polyester clothes, and detection capability of LLL image intensifier is stronger for the human target wearing cotton clothes. Experimental results show that the LLL image intensifiers have longer visual ranges for targets who wear cotton clothes than targets who wear same color but polyester clothes, and have longer visual ranges for targets who wear light-colored clothes than targets who wear dark-colored clothes. And in the full moon illumination conditions, LLL image intensifiers are more sensitive to the clothes' material.

  3. Low Endogenous Fibroblast Growth Factor 2 Levels Are Associated With Heightened Conditioned Fear Expression in Rats and Humans.

    Science.gov (United States)

    Graham, Bronwyn M; Zagic, Dino; Richardson, Rick

    2017-10-15

    Hippocampal concentrations of the neurotrophic factor fibroblast growth factor 2 (FGF2) are negatively associated with the expression of fear following conditioning in rats. Heightened conditioned fear expression may be a prospective risk factor for the development of human anxiety and trauma disorders. However, the relationship between conditioned fear expression and FGF2 is yet to be established in humans. Using a cross-species approach, we first investigated the relationship between serum concentrations of FGF2 and individual differences in conditioned fear expression in rats (n = 19). We then subjected 88 human participants, who were recruited from university and community advertisements, to a differential fear conditioning procedure and assessed the relationship between salivary concentrations of FGF2 and fear expression to a conditioned stimulus (CS) (a stimulus paired with a shock) and a CS that was never paired with shock. Rats with low serum levels of FGF2 exhibited significantly more freezing than rats with high serum levels of FGF2. Similarly, relative to those with high salivary FGF2, human participants with low salivary FGF2 exhibited significantly heightened skin conductance responses to the CS without shock during fear conditioning and to both the CS with shock and CS without shock during fear recall. These studies establish that peripheral markers of FGF2 concentrations are negatively associated with fear expression in both rats and humans. To the extent that conditioned fear expression predicts anxiety and trauma disorder vulnerability, FGF2 may be a clinically useful biomarker in the prediction and eventual prevention of these disorders. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  4. Ontology-Based High-Level Context Inference for Human Behavior Identification

    Science.gov (United States)

    Villalonga, Claudia; Razzaq, Muhammad Asif; Khan, Wajahat Ali; Pomares, Hector; Rojas, Ignacio; Lee, Sungyoung; Banos, Oresti

    2016-01-01

    Recent years have witnessed a huge progress in the automatic identification of individual primitives of human behavior, such as activities or locations. However, the complex nature of human behavior demands more abstract contextual information for its analysis. This work presents an ontology-based method that combines low-level primitives of behavior, namely activity, locations and emotions, unprecedented to date, to intelligently derive more meaningful high-level context information. The paper contributes with a new open ontology describing both low-level and high-level context information, as well as their relationships. Furthermore, a framework building on the developed ontology and reasoning models is presented and evaluated. The proposed method proves to be robust while identifying high-level contexts even in the event of erroneously-detected low-level contexts. Despite reasonable inference times being obtained for a relevant set of users and instances, additional work is required to scale to long-term scenarios with a large number of users. PMID:27690050

  5. Ontology-Based High-Level Context Inference for Human Behavior Identification

    Directory of Open Access Journals (Sweden)

    Claudia Villalonga

    2016-09-01

    Full Text Available Recent years have witnessed a huge progress in the automatic identification of individual primitives of human behavior, such as activities or locations. However, the complex nature of human behavior demands more abstract contextual information for its analysis. This work presents an ontology-based method that combines low-level primitives of behavior, namely activity, locations and emotions, unprecedented to date, to intelligently derive more meaningful high-level context information. The paper contributes with a new open ontology describing both low-level and high-level context information, as well as their relationships. Furthermore, a framework building on the developed ontology and reasoning models is presented and evaluated. The proposed method proves to be robust while identifying high-level contexts even in the event of erroneously-detected low-level contexts. Despite reasonable inference times being obtained for a relevant set of users and instances, additional work is required to scale to long-term scenarios with a large number of users.

  6. Recent results on the linearity of the dose-response relationship for radiation-induced mutations in human cells by low dose levels

    International Nuclear Information System (INIS)

    Traut, H.

    1987-01-01

    Five studies made by various authors in the last years are discussed, which are significant in that the response of human cells to low-dose irradiation is determined directly and not by extrapolation, and which also provide information on the mutagenic effects of low radiation doses. The results of these studies do not indicate any other than a linear response for induction of mutations by low-dose irradiation, nor are there any reasons observable for assuming the existence of a threshold dose. It is very likely therefore that cancer initiation at the low dose level also is characterized by a linear relationship. Although threshold dose levels cannot generally be excluded, and maybe are only too low to be detected by experiment, there is no plausible biophysical argument for assuming the existence of such microdose threshold. (orig./MG) [de

  7. Response of Human Skin Equivalents to Sarcoptes scabiei

    Science.gov (United States)

    MORGAN, MARJORIE S.; ARLIAN, LARRY G.

    2010-01-01

    Studies have shown that molecules in an extract made from bodies of the ectoparasitic mite, Sarcoptes scabiei De Geer, modulate cytokine secretion from cultured human keratinocytes and fibroblasts. In vivo, in the parasitized skin, these cells interact with each other by contact and cytokine mediators and with the matrix in which they reside. Therefore, these cell types may function differently together than they do separately. In this study, we used a human skin equivalent (HSE) model to investigate the influence of cellular interactions between keratinocytes and fibroblasts when the cells were exposed to active/burrowing scabies mites, mite products, and mite extracts. The HSE consisted of an epidermis of stratified stratum corneum, living keratinocytes, and basal cells above a dermis of fibroblasts in a collagen matrix. HSEs were inoculated on the surface or in the culture medium, and their cytokine secretions on the skin surface and into the culture medium were determined by enzyme-linked immunosorbent assay. Active mites on the surface of the HSE induced secretion of cutaneous T cell-attracting chemokine, thymic stromal lymphopoietin, interleukin (IL)-1α, IL-1β, IL-1 receptor antagonist (IL-1ra), IL-6, IL-8, monocyte chemoattractant protein-1, granulocyte/macrophage colony-stimulating factor, and macrophage colony-stimulating factor. The main difference between HSEs and monocultured cells was that the HSEs produced the proinflammatory cytokines IL-1α and IL-1β and their competitive inhibitor IL-1ra, whereas very little of these mediators was previously found for cultured keratinocytes and fibroblasts. It is not clear how the balance between these cytokines influences the overall host response. However, IL-1ra may contribute to the depression of an early cutaneous inflammatory response to scabies in humans. These contrasting results illustrate that cell interactions are important in the host’s response to burrowing scabies mites. PMID:20939384

  8. Performance objectives for disposal of low-level radioactive wastes on the Oak Ridge Reservation

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1986-01-01

    This paper presents a set of performance objectives for disposal of low-level radioactive wastes in a new facility on the Oak Ridge Reservation. The principal performance objectives include (1) a limit on annual committed effective dose equivalent averaged over a lifetime of 0.25 mSv (25 mrem) for any member of the general public beyond the boundary of the disposal facility, and (2) a limit on annual committed effective dose equivalent averaged over a lifetime of 1 mSv (100 mrem) and a limit on committed effective dose equivalent in any year of 5 mSv (500 mrem) for any individual who inadvertently intrudes onto the disposal site after loss of active institutional controls. The use of annual committed effective dose equivalents averaged over a lifetime departs from customary practice in environmental radiation standards in the U.S. of specifying limits on actual dose received in any year to whole body or the critical organ, but provides a set of performance objectives that are more closely related to the fundamental goal of limiting risk from chronic lifetime exposures. (Auth.)

  9. Low-level waste management

    International Nuclear Information System (INIS)

    Levin, G.B.

    1980-01-01

    An overview of the current situation in the United States and a look to the future of low-level waste management are presented. Current problems and challenges are discussed, such as: the need of additional disposal sites in the future; risks and costs involved in transport of low-level wastes; reduction of low-level waste volume through smelting, incineration, and storage for wastes containing nuclides with short half lives; development of a national policy for the management of low-level waste, and its implementation through a sensible system of regulations. Establishing a success with low-level waste management should provide the momentum and public confidence needed to continue on and to resolve the technical and politically more difficult low-level waste problems

  10. Low-level contrast statistics of natural images can modulate the frequency of event-related potentials (ERP in humans

    Directory of Open Access Journals (Sweden)

    Masoud Ghodrati

    2016-12-01

    Full Text Available Humans are fast and accurate in categorizing complex natural images. It is, however, unclear what features of visual information are exploited by brain to perceive the images with such speed and accuracy. It has been shown that low-level contrast statistics of natural scenes can explain the variance of amplitude of event-related potentials (ERP in response to rapidly presented images. In this study, we investigated the effect of these statistics on frequency content of ERPs. We recorded ERPs from human subjects, while they viewed natural images each presented for 70 ms. Our results showed that Weibull contrast statistics, as a biologically plausible model, explained the variance of ERPs the best, compared to other image statistics that we assessed. Our time-frequency analysis revealed a significant correlation between these statistics and ERPs’ power within theta frequency band (~3-7 Hz. This is interesting, as theta band is believed to be involved in context updating and semantic encoding. This correlation became significant at ~110 ms after stimulus onset, and peaked at 138 ms. Our results show that not only the amplitude but also the frequency of neural responses can be modulated with low-level contrast statistics of natural images and highlights their potential role in scene perception.

  11. Vitrification of low level and mixed (radioactive and hazardous) wastes: Lessons learned from high level waste vitrification

    International Nuclear Information System (INIS)

    Jantzen, C.M.

    1994-01-01

    Borosilicate glasses will be used in the USA and in Europe immobilize radioactive high level liquid wastes (HLLW) for ultimate geologic disposal. Simultaneously, tehnologies are being developed by the US Department of Energy's (DOE) Nuclear Facility sites to immobilize low-level and mixed (radioactive and hazardous) wastes (LLMW) in durable glass formulations for permanent disposal or long-term storage. Vitrification of LLMW achieves large volume reductions (86--97 %) which minimize the associated long-term storage costs. Vitrification of LLMW also ensures that mixed wastes are stabilized to the highest level reasonably possible, e.g. equivalent to HLLW, in order to meet both current and future regulatory waste disposal specifications The tehnologies being developed for vitrification of LLMW rely heavily on the technologies developed for HLLW and the lessons learned about process and product control

  12. Low-level radioactive waste, mixed low-level radioactive waste, and biomedical mixed waste

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This document describes the proceedings of a workshop entitled: Low-Level Radioactive Waste, Mixed Low-Level Radioactive Waste, and Biomedical Mixed Waste presented by the National Low-Level Waste Management Program at the University of Florida, October 17-19, 1994. The topics covered during the workshop include technical data and practical information regarding the generation, handling, storage and disposal of low-level radioactive and mixed wastes. A description of low-level radioactive waste activities in the United States and the regional compacts is presented

  13. Low-level Radioactive waste Management

    International Nuclear Information System (INIS)

    1991-01-01

    This meeting describes low-level radioactive waste management problems and contains 8 papers: 1 Low-level radioactive waste management: exemption concept and criteria used by international organizations. 2 Low-level radioactive waste management: french and foreign regulations 3 Low-level radioactive waste management in EDF nuclear power plants (FRANCE) 4 Low-level radioactive waste management in COGEMA (FRANCE) 5 Importance of low-level radioactive wastes in dismantling strategy in CEA (FRANCE) 6 Low-level radioactive waste management in hospitals 7 Low-level radioactive waste disposal: radiation protection laws 8 Methods of low-level radioactive materials measurements during reactor dismantling or nuclear facilities demolition (FRANCE)

  14. Saccharomyces cerevisiae show low levels of traversal across human endothelial barrier in vitro [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Roberto Pérez-Torrado

    2017-09-01

    Full Text Available Background:  Saccharomyces cerevisiae is generally considered safe, and is involved in the production of many types of foods and dietary supplements. However, some isolates, which are genetically related to strains used in brewing and baking, have shown virulent traits, being able to produce infections in humans, mainly in immunodeficient patients. This can lead to systemic infections in humans. Methods: In this work, we studied S. cerevisiae isolates in an in vitro human endothelial barrier model, comparing their behaviour with that of several strains of the related pathogens Candida glabrata and Candida albicans. Results: The results showed that this food related yeast is able to cross the endothelial barrier in vitro. However, in contrast to C. glabrata and C. albicans, S. cerevisiae showed very low levels of traversal. Conclusions: We conclude that using an in vitro human endothelial barrier model with S. cerevisiae can be useful to evaluate the safety of S. cerevisiae strains isolated from foods.

  15. Perspectives on repeated low-level blast and the measurement of neurotrauma in humans as an occupational exposure risk

    Science.gov (United States)

    Carr, W.; Dell, K. C.; Yanagi, M. A.; Hassan, D. M.; LoPresti, M. L.

    2017-11-01

    A pressing question in military medical research is the nature and degree of effects on the human brain from occupational repeated exposure to low-level explosive blast, but reliable and effective means to objectively measure such effects remain elusive. In survey results, headache, difficulty sleeping, irritability, cognitive impairment, and a variety of other symptoms consistent with post-concussive syndrome have been reported by those exposed to blast and there was positive correlation between degree of blast exposure and degree of symptomology, but an important goal is to obtain more objective evidence of an effect than self-report alone. This review reflects recent efforts to measure and evaluate such hypothesized effects and current recommendations for ongoing study. Optimal measures are likely those with sensitivity and specificity to systemic effects in mild neurotrauma, that have minimal to no volitional component, and that can be sampled relatively quickly with minimal intrusion in prospective, observational field studies during routine training with explosives. An understanding of an association between parameters of exposure to repeated low-level blast and negative neurologic effects would support the evaluation of clinical implications and development of protective equipment and surveillance protocols where warranted. At present, low-level blast exposure surveillance measurements do not exist as a systematic record for any professional community.

  16. Dermal damage promoted by repeated low-level UV-A1 exposure despite tanning response in human skin.

    Science.gov (United States)

    Wang, Frank; Smith, Noah R; Tran, Bao Anh Patrick; Kang, Sewon; Voorhees, John J; Fisher, Gary J

    2014-04-01

    Solar UV irradiation causes photoaging, characterized by fragmentation and reduced production of type I collagen fibrils that provide strength to skin. Exposure to UV-B irradiation (280-320 nm) causes these changes by inducing matrix metalloproteinase 1 and suppressing type I collagen synthesis. The role of UV-A irradiation (320-400 nm) in promoting similar molecular alterations is less clear yet important to consider because it is 10 to 100 times more abundant in natural sunlight than UV-B irradiation and penetrates deeper into the dermis than UV-B irradiation. Most (approximately 75%) of solar UV-A irradiation is composed of UV-A1 irradiation (340-400 nm), which is also the primary component of tanning beds. To evaluate the effects of low levels of UV-A1 irradiation, as might be encountered in daily life, on expression of matrix metalloproteinase 1 and type I procollagen (the precursor of type I collagen). In vivo biochemical analyses were conducted after UV-A1 irradiation of normal human skin at an academic referral center. Participants included 22 healthy individuals without skin disease. Skin pigmentation was measured by a color meter (chromometer) under the L* variable (luminescence), which ranges from 0 (black) to 100 (white). Gene expression in skin samples was assessed by real-time polymerase chain reaction. Lightly pigmented human skin (L* >65) was exposed up to 4 times (1 exposure/d) to UV-A1 irradiation at a low dose (20 J/cm2), mimicking UV-A levels from strong sun exposure lasting approximately 2 hours. A single exposure to low-dose UV-A1 irradiation darkened skin slightly and did not alter matrix metalloproteinase 1 or type I procollagen gene expression. With repeated low-dose UV-A1 irradiation, skin darkened incrementally with each exposure. Despite this darkening, 2 or more exposures to low-dose UV-A1 irradiation significantly induced matrix metalloproteinase 1 gene expression, which increased progressively with successive exposures. Repeated UV-A1

  17. Hydrocortisone and triiodothyronine regulate hyaluronate synthesis in a tissue-engineered human dermal equivalent through independent pathways.

    Science.gov (United States)

    Deshpande, Madhura; Papp, Suzanne; Schaffer, Lana; Pouyani, Tara

    2015-02-01

    Hydrocortisone (HC) and triiodothyronine (T3) have both been shown to be capable of independently inhibiting hyaluronate (HA, hyaluronic acid) synthesis in a self-assembled human dermal equivalent (human dermal matrix). We sought to investigate the action of these two hormones in concert on extracellular matrix formation and HA inhibition in the tissue engineered human dermal matrix. To this end, neonatal human dermal fibroblasts were cultured in defined serum-free medium for 21 days in the presence of each hormone alone, or in combination, in varying concentrations. Through a process of self-assembly, a substantial dermal extracellular matrix formed that was characterized. The results of these studies demonstrate that combinations of the hormones T3 and hydrocortisone showed significantly higher levels of hyaluronate inhibition as compared to each hormone alone in the human dermal matrix. In order to gain preliminary insight into the genes regulating HA synthesis in this system, a differential gene array analysis was conducted in which the construct prepared in the presence of 200 μg/mL HC and 0.2 nM T3 was compared to the normal construct (0.4 μg/mL HC and 20 pM T3). Using a GLYCOv4 gene chip containing approximately 1260 human genes, we observed differential expression of 131 genes. These data suggest that when these two hormones are used in concert a different mechanism of inhibition prevails and a combination of degradation and inhibition of HA synthesis may be responsible for HA regulation in the human dermal matrix. Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. In vitro-in vivo extrapolation: estimation of human serum concentrations of chemicals equivalent to cytotoxic concentrations in vitro

    International Nuclear Information System (INIS)

    Guelden, Michael; Seibert, Hasso

    2003-01-01

    In the present study an extrapolation model for estimating serum concentrations of chemicals equivalent to in vitro effective concentrations is developed and applied to median cytotoxic concentrations (EC 50 ) determined in vitro. Nominal concentrations of a chemical in serum and in vitro are regarded as equivalent, if they result in the same aqueous concentration of the unbound form. The algorithm used is based on equilibrium distribution and requires albumin binding data, the octanol-water partition coefficient (K ow ), and the albumin concentrations and lipid volume fractions in vitro and in serum. The chemicals studied cover wide ranges of cytotoxic potency (EC 50 : 2.5-530000 μM) and lipophilicity (log K ow : -5 to 7). Their albumin binding characteristics have been determined by means of an in vitro cytotoxicity test as described previously. The equivalent serum concentrations of 19 of the 33 compounds investigated, having high protein binding and/or lipophilicity, were substantially higher than the EC 50 -values, by factors of 2.5-58. Prominent deviations between the equivalent nominal concentrations in serum and in vitro were largely restricted to chemicals with higher cytotoxic potency (EC 50 ≤1000 μM). The results suggest that estimates of equivalent serum concentrations based on in vitro data are robust for chemicals with low lipophilicity (log K ow ≤2) and low potency (EC 50 >1000 μM). With more potent chemicals or those with higher lipophilicity partitioning into lipids and/or binding to serum proteins have to be taken into account when estimating in vivo serum concentrations equivalent to in vitro effective concentrations

  19. Evidence from mammalian studies on genetic effects of low level irradiation

    International Nuclear Information System (INIS)

    Searle, A.G.

    1989-01-01

    The major components of genetic damage and associated human risks are discussed, together with the experimental evidence on induction rates of chromosome anomalies in mice, and monkeys male and female germ cells, using low and high LET low level irradiation. (UK)

  20. Mixed and Low-Level Waste Treatment Facility Project

    International Nuclear Information System (INIS)

    1992-04-01

    Mixed and low-level wastes generated at the Idaho National Engineering Laboratory (INEL) are required to be managed according to applicable State and Federal regulations, and Department of Energy Orders that provide for the protection of human health and the environment. The Mixed and Low-Level Waste Treatment Facility Project was chartered in 1991, by the Department of Energy to provide treatment capability for these mixed and low-level waste streams. The first project task consisted of conducting engineering studies to identify the waste streams, their potential treatment strategies, and the requirements that would be imposed on the waste streams and the facilities used to process them. This report documents those studies so the project can continue with an evaluation of programmatic options, system tradeoff studies, and the conceptual design phase of the project. This report, appendix B, comprises the engineering design files for this project study. The engineering design files document each waste steam, its characteristics, and identified treatment strategies

  1. Radon measurements during the building of a low-level laboratory

    CERN Document Server

    Antanasijevic, R; Bikit, I; Banjanac, R; Dragic, A; Joksimovic, D; Krmpotic, D; Udovicic, V; Vukovic, J

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m sup 2. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm sup - sup 3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  2. Radon measurements during the building of a low-level laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J

    1999-06-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m{sup 2}. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm{sup -3} and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  3. Radon measurements during the building of a low-level laboratory

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J.

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m 2 . The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm -3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied

  4. A digital retina-like low-level vision processor.

    Science.gov (United States)

    Mertoguno, S; Bourbakis, N G

    2003-01-01

    This correspondence presents the basic design and the simulation of a low level multilayer vision processor that emulates to some degree the functional behavior of a human retina. This retina-like multilayer processor is the lower part of an autonomous self-organized vision system, called Kydon, that could be used on visually impaired people with a damaged visual cerebral cortex. The Kydon vision system, however, is not presented in this paper. The retina-like processor consists of four major layers, where each of them is an array processor based on hexagonal, autonomous processing elements that perform a certain set of low level vision tasks, such as smoothing and light adaptation, edge detection, segmentation, line recognition and region-graph generation. At each layer, the array processor is a 2D array of k/spl times/m hexagonal identical autonomous cells that simultaneously execute certain low level vision tasks. Thus, the hardware design and the simulation at the transistor level of the processing elements (PEs) of the retina-like processor and its simulated functionality with illustrative examples are provided in this paper.

  5. Cancer-specific SNPs originate from low-level heteroplasmic variants in human mitochondrial genomes of a matched cell line pair.

    Science.gov (United States)

    Hedberg, Annica; Knutsen, Erik; Løvhaugen, Anne Silje; Jørgensen, Tor Erik; Perander, Maria; Johansen, Steinar D

    2018-04-19

    Low-level mitochondrial heteroplasmy is a common phenomenon in both normal and cancer cells. Here, we investigate the link between low-level heteroplasmy and mitogenome mutations in a human breast cancer matched cell line by high-throughput sequencing. We identified 23 heteroplasmic sites, of which 15 were common between normal cells (Hs578Bst) and cancer cells (Hs578T). Most sites were clustered within the highly conserved Complex IV and ribosomal RNA genes. Two heteroplasmic variants in normal cells were found as fixed mutations in cancer cells. This indicates a positive selection of these variants in cancer cells. RNA-Seq analysis identified upregulated L-strand specific transcripts in cancer cells, which include three mitochondrial long non-coding RNA molecules. We hypothesize that this is due to two cancer cell-specific mutations in the control region.

  6. Very low levels of 6-keto-prostaglandin F 1/sub α/ in human plasma

    International Nuclear Information System (INIS)

    Siess, W.; Dray, F.

    1982-01-01

    Two stable derivatives of PGI 2 , its nonenzymatic hydrolysis product (6-keto-PGF 1 /sub α/) and an enzymatic metabolite (6, 15-diketo-PGF 1 /sub α/) were determined in human plasma and urine. These compounds were measured by RIA after separation on rp-HPLC. Previous purification of the samples on rp=HPLC markedly enhanced the specificity of the RIA determinations of those compounds in plasma and urine. The PGI 2 derivative 6-keto-PGF 1 /sub α/ was detected in both plasma (4.7 +/- 3.2 pg/ml, mean +/- S.D., n = 34) and urine (166 +/- 61 pg/ml, n = 9). No gender differences of the plasma or urinary levels of 6-keto-PGF 1 /sub α/ were found. The PGI 2 metabolite 6, 15-diketo-PGF 1 /sub α/ was not measurable in plasma or urine ( 2 in man. When [ 3 H]PGI 2 was added to citrated blood immediately after venipuncture, it was recovered entirely as [ 3 H]6-keto-PGF 1 /sub α/ after rp-HPLC. Therefore any circulating PGI 2 would be measured as 6-keto-PGF 1 /sub α/ by our method. The results obtained suggest that PGI 2 could be present in human venous blood under physiological conditions, but only in very low concentrations

  7. Low-level radiation

    International Nuclear Information System (INIS)

    Myers, D.K.

    1982-05-01

    It is known that the normal incidence of cancer in human populations is increased by exposure to moderately high doses of ionizing radiation. At background radiation levels or at radiation levels which are 100 times greater, the potential health risks are considered to be directly proportional to the total accumulated dose of radiation. Some of the uncertainties associated with this assumption and with the accepted risk estimates have been critically reviewed in this document. The general scientific consensus at present suggests that the accepted risk estimates may exaggerate the actual risk of low levels of sparsely ionizing radiations (beta-, gamma- or X-rays) somewhat but are unlikely to overestimate the actual risks of densely ionizing radiations (fast neutrons, alpha-particles). At the maximum permissible levels of exposure for radiation workers in nuclear power stations, the potential health hazards in terms of life expectancy would be comparable to those encountered in transportation and public utilities or in the construction industry. At the average radiation exposures received by these workers in practice, the potential health hazards are similar to those associated with safe categories of industries. Uranium mining remains a relativly hazardous occupation. In terms of absolute numbers, the genetic hazards, which are less well established, are thought to be smaller than the carcinogenic hazards of radiation when only the first generation is considered but to be of the same order of magnitude as the carcinogenic hazards when the total number of induced genetic disorders is summed over all generations

  8. A Technique of Teaching the Principle of Equivalence at Ground Level

    Science.gov (United States)

    Lubrica, Joel V.

    2016-01-01

    This paper presents one way of demonstrating the Principle of Equivalence in the classroom. Teaching the Principle of Equivalence involves someone experiencing acceleration through empty space, juxtaposed with the daily encounter with gravity. This classroom activity is demonstrated with a water-filled bottle containing glass marbles and…

  9. Effects of a foot placement constraint on use of motor equivalence during human hopping.

    Directory of Open Access Journals (Sweden)

    Arick G Auyang

    Full Text Available Humans can robustly locomote over complex terrains even while simultaneously attending to other tasks such as accurate foot placement on the ground. We investigated whether subjects would exploit motor redundancy across the joints of the leg to stabilize overall limb kinematics when presented with a hopping task that constrained foot placement position. Subjects hopped in place on one leg (2.2 Hz while having to place their foot into one of three target sizes upon landing (0.250, 0.063, 0.010 m(2. As takeoff and landing angles are critical to this task performance, we hypothesized smaller target sizes would increase the need to stabilize (i.e., make more consistent the leg orientation through motor equivalent combinations of segment angles. As it was not critical to the targeting task, we hypothesized no changes for leg length stabilization across target size. With smaller target sizes, we saw total segment angle variance increase due to greater signal-dependent noise associated with an increased activation of leg extensor muscles (medial and lateral gastrocnemius, vastus medialis, vastus lateralis and rectus femoris. At smaller target sizes, more segment angle variance was aligned to kinematic deviations with the goal of maintaining leg orientation trajectory. We also observed a decrease in the variance structure for stabilizing leg length at the smallest target conditions. This trade-off effect is explained by the nearly orthogonal relationship between the two goal-equivalent manifolds for leg length vs. leg orientation stabilization. Our results suggest humans increasingly rely on kinematic redundancy in their legs to achieve robust, consistent locomotion when faced with novel conditions that constrain performance requirements. These principles may generalize to other human locomotor gaits and provide important insights into the control of the legs during human walking and running.

  10. Lawrence Livermore National Laboratory low-level waste systems performance assessment

    International Nuclear Information System (INIS)

    1990-11-01

    This Low-Level Radioactive Waste (LLW) Systems Performance Assessment (PA) presents a systematic analysis of the potential risks posed by the Lawrence Livermore National Laboratory (LLNL) waste management system. Potential risks to the public and environment are compared to established performance objectives as required by DOE Order 5820.2A. The report determines the associated maximum individual committed effective dose equivalent (CEDE) to a member of the public from LLW and mixed waste. A maximum annual CEDE of 0.01 mrem could result from routine radioactive liquid effluents. A maximum annual CEDE of 0.003 mrem could result from routine radioactive gaseous effluents. No other pathways for radiation exposure of the public indicated detectable levels of exposure. The dose rate, monitoring, and waste acceptance performance objectives were found to be adequately addressed by the LLNL Program. 88 refs., 3 figs., 17 tabs

  11. Mixed and Low-Level Waste Treatment Facility project

    International Nuclear Information System (INIS)

    1992-04-01

    Mixed and low-level wastes generated at the Idaho National Engineering Laboratory (INEL) are required to be managed according to applicable State and Federal regulations, and Department of Energy Orders that provide for the protection of human health and the environment. The Mixed and Low-Level Waste Treatment Facility Project was chartered in 1991, by the Department of Energy to provide treatment capability for these mixed and low-level waste streams. The first project task consisted of conducting engineering studies to identify the waste streams, their potential treatment strategies, and the requirements that would be imposed on the waste streams and the facilities used to process them. The engineering studies, initiated in July 1991, identified 37 mixed waste streams, and 55 low-level waste streams. This report documents the waste stream information and potential treatment strategies, as well as the regulatory requirements for the Department of Energy-owned treatment facility option. The total report comprises three volumes and two appendices. This report consists of Volume 1, which explains the overall program mission, the guiding assumptions for the engineering studies, and summarizes the waste stream and regulatory information, and Volume 2, the Waste Stream Technical Summary which, encompasses the studies conducted to identify the INEL's waste streams and their potential treatment strategies

  12. Rokkasho low-level radioactive waste disposal in Japan

    International Nuclear Information System (INIS)

    Takahashi, Y.

    1994-01-01

    Japan Nuclear Fuel Limited commenced the operation of the shallow land disposal of low-level radioactive waste from reactor operation, in 1992 at Rokkasho site in Aomori Prefecture. JNFL is private company whose main activities within the responsibility of JNFL are: 1) Disposal of low-level radioactive waste, 2) Uranium enrichment, 3) Reprocessing of spent nuclear fuels, 4) Temporary storage of returned wastes from COGEMA and BNFL by reprocessing contracts, prior to disposal. JNFL selected the site for the disposal of LLW at Rokkasho in Aomori Prefecture, then bought land of 3.4 million m 2 . Among waste spectrum, LLWs from nuclear power plants, from uranium enrichment and from reprocessing are to be managed by JNFL, including dismantling of these facilities, and JNFL has plan to dispose about 600 thousand m 3 of wastes ultimately. On the middle of November 1990 JNFL got the permission of the application for 40 thousand m 3 (equivalent to 200,000 drums each with a 200-liter capacity) of reactor operating wastes which is solidified with cement, bitumen or plastics as a first stage. And after the construction work for about 2 years, the operations started at Dec. 8th, 1992. The Disposal center has already accepted about 24,000 LLW drums as of the end of February, 1994. (author)

  13. Psilocybin impairs high-level but not low-level motion perception.

    Science.gov (United States)

    Carter, Olivia L; Pettigrew, John D; Burr, David C; Alais, David; Hasler, Felix; Vollenweider, Franz X

    2004-08-26

    The hallucinogenic serotonin(1A&2A) agonist psilocybin is known for its ability to induce illusions of motion in otherwise stationary objects or textured surfaces. This study investigated the effect of psilocybin on local and global motion processing in nine human volunteers. Using a forced choice direction of motion discrimination task we show that psilocybin selectively impairs coherence sensitivity for random dot patterns, likely mediated by high-level global motion detectors, but not contrast sensitivity for drifting gratings, believed to be mediated by low-level detectors. These results are in line with those observed within schizophrenic populations and are discussed in respect to the proposition that psilocybin may provide a model to investigate clinical psychosis and the pharmacological underpinnings of visual perception in normal populations.

  14. WE-FG-207B-07: Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results

    International Nuclear Information System (INIS)

    Symons, R; Cork, T; Folio, L; Bluemke, D; Pourmorteza, A

    2016-01-01

    Purpose: To evaluate the feasibility of using a whole-body photon counting detector (PCD) CT scanner for low dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Methods: Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom and 2 human volunteers were acquired. Phantom images were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp), while human images were acquired at vendor recommended low-dose lung cancer screening settings. EID and PCD images were compared for quantitative Hounsfield unit accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGNs) and emphysema. Results: The PCD Hounsfield unit accuracy was better for water at all scan parameters, and for lung, GGN and emphysema equivalent regions of interest (ROIs) at 1.5 and 0.75 mGy. PCD attenuation accuracy was more consistent for all scan parameters (all P<0.01), while Hounsfield units for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P<0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2±0.3 vs 15.8±0.2, P=0.03; 16.1±0.3 vs 18.0±0.4, P=0.003; and 16.1±0.3 vs 17.9±0.3, P=0.001, respectively), resulting in superior CNR for the detection of GGNs and emphysema at 100 and 80 kVp. Significantly lower PCD noise levels were confirmed in volunteer images. Conclusion: PCD provided better Hounsfield unit accuracy for lung, ground-glass, and emphysema-equivalent foams at 1.5 and 0.75 mGy with less variability than EID. Additionally, PCD showed less noise, and higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

  15. WE-FG-207B-07: Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results

    Energy Technology Data Exchange (ETDEWEB)

    Symons, R; Cork, T; Folio, L; Bluemke, D; Pourmorteza, A [National Institutes of Health Clinical Center, Bethesda, MD (United States)

    2016-06-15

    Purpose: To evaluate the feasibility of using a whole-body photon counting detector (PCD) CT scanner for low dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Methods: Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom and 2 human volunteers were acquired. Phantom images were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp), while human images were acquired at vendor recommended low-dose lung cancer screening settings. EID and PCD images were compared for quantitative Hounsfield unit accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGNs) and emphysema. Results: The PCD Hounsfield unit accuracy was better for water at all scan parameters, and for lung, GGN and emphysema equivalent regions of interest (ROIs) at 1.5 and 0.75 mGy. PCD attenuation accuracy was more consistent for all scan parameters (all P<0.01), while Hounsfield units for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P<0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2±0.3 vs 15.8±0.2, P=0.03; 16.1±0.3 vs 18.0±0.4, P=0.003; and 16.1±0.3 vs 17.9±0.3, P=0.001, respectively), resulting in superior CNR for the detection of GGNs and emphysema at 100 and 80 kVp. Significantly lower PCD noise levels were confirmed in volunteer images. Conclusion: PCD provided better Hounsfield unit accuracy for lung, ground-glass, and emphysema-equivalent foams at 1.5 and 0.75 mGy with less variability than EID. Additionally, PCD showed less noise, and higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

  16. Effects of low-level blast exposure on the nervous system: Is there really a controversy?

    Directory of Open Access Journals (Sweden)

    Gregory A Elder

    2014-12-01

    Full Text Available High-pressure blast waves can cause extensive CNS injury in humans. However, in combat settings such as Iraq and Afghanistan, lower level exposures associated with mild TBI (mTBI or subclinical exposure have been much more common. Yet controversy exists concerning what traits can be attributed to low-level blast, in large part due to the difficulty of distinguishing blast-related mTBI from post-traumatic stress disorder (PTSD. We describe how TBI is defined in humans and the problems posed in using current definitions to recognize blast-related mTBI. We next consider the problem of applying definitions of human mTBI to animal models, in particular that TBI severity in humans is defined in relation to alteration of consciousness at the time of injury, which typically cannot be assessed in animals. However, based on outcome assessments a condition of low-level blast exposure can be defined in animals that likely approximates human mTBI or subclinical exposure. We review blast injury modeling in animals noting that inconsistencies in experimental approach have contributed to uncertainty over the effects of low-level blast. Yet animal studies show that low-level blast pressure waves are transmitted to the brain. In brain low-level blast exposures cause behavioral, biochemical, pathological and physiological effects on the nervous system including the induction of PTSD-related behavioral traits in the absence of a psychological stressor. We review the relationship of blast exposure to chronic neurodegenerative diseases noting the paradoxical lowering of Abeta by blast, which along with other observations suggest that blast-related TBI is pathophysiologically distinct from non-blast TBI. Human neuroimaging studies show that blast-related mTBI is associated with a variety of chronic effects that are unlikely to be explained by co-morbid PTSD. We conclude that abundant evidence supports low-level blast as having long-term effects on the nervous system.

  17. Quantitative comparisons of genotoxic effects of atomic energy and fossil-fuelled energy. Rad-equivalences for ethylene, ethylene oxide and formaldehyde - consequences for decisions at Government level

    International Nuclear Information System (INIS)

    Latarjet, R.; Averbeck, D.; Levy, S.; Poirier, V.

    1982-01-01

    Rad-equivalences have been determined on the basis of data on the genotoxic effects of low linear energy transfer ionizing radiation and of three chemical pollutants - ethylene, ethylene oxide and formaldehyde - emitted from energy-producing power plants. In the case of ethylene and its metabolite, ethylene oxide, the conditions were particularly favourable because the equivalences could be based on the induction of total mutations in the mouse, which is the same genetic end-point used for the assessment of radiation risks. Once established, the rad-equivalences were used (a) to extrapolate the rules adopted for radiation to each of these two compounds and (b) to make recommendations for exposed workers at 'hot spots' and for the general population. Measurements of ethylene in power plants and in the atmosphere of Paris have indicated that in most cases the measured values fall within the recommended values. However, pollution by ethylene oxide in cold sterilization units should be reduced. Rad-equivalences obtained for lethal effects, and for the induction of chromosome aberrations by formaldehyde in human cells in vitro, suggest that the maximum admissible concentrations are far too high in most countries and must be reconsidered. In France, the Ministry of Health is taking the rad-equivalences into consideration for the preparation of a law regulating pollution by ethylene and ethylene oxide - as a first step. These results show that rad-equivalences can be used for risk assessments of genotoxic effects from power plants and that decisions can be made by extrapolating the rules adopted for radiation protection to some chemical mutagens, when certain strict conditions are fulfilled. (author)

  18. NTP monograph on health effects of low-level lead.

    Science.gov (United States)

    2012-06-01

    Although reductions in lead (Pb) exposure for the U.S. population have resulted in lower blood Pb levels over time, epidemiological studies continue to provide evidence of health effects at lower and lower blood Pb levels. Low-level Pb was selected for evaluation by the National Toxicology Program (NTP) because of (1) the availability of a large number of epidemiological studies of Pb, (2) a nomination by the National Institute for Occupational Safety and Health for an assessment of Pb at lower levels of exposure, and (3) public concern for effects of Pb in children and adults. This evaluation summarizes the evidence in humans and presents conclusions on health effects in children and adults associated with low-level Pb exposure as indicated by less than 10 micrograms of Pb per deciliter of blood (Monograph on Health Effects of Low-Level Lead. The document and appendices are available at http://ntp.niehs.nih.gov/go/evals. This document provides background on Pb exposure and includes a review of the primary epidemiological literature for evidence that low-level Pb is associated with neurological, immunological, cardiovascular, renal, and/or reproductive and developmental effects. The NTP Monograph presents specific conclusions for each health effect area. Overall, the NTP concludes that there is sufficient evidence that blood Pb levels Monograph on November 17-18, 2011 (http://ntp.niehs.nih.gov/go/37090.

  19. Mixed and Low-Level Waste Treatment Facility project

    International Nuclear Information System (INIS)

    1992-04-01

    Mixed and low-level wastes generated at the Idaho National Engineering Laboratory (INEL) are required to be managed according to applicable State and Federal regulations, and Department of Energy Orders that provide for the protection of human health and the environment. The Mixed and Low-Level Waste Treatment Facility Project was chartered in 1991, by the Department of Energy to provide treatment capability for these mixed and low-level waste streams. The first project task consisted of conducting engineering studies to identify the waste streams, their potential treatment strategies, and the requirements that would be imposed on the waste streams and the facilities used to process them. This report, Appendix A, Environmental ampersand Regulatory Planning ampersand Documentation, identifies the regulatory requirements that would be imposed on the operation or construction of a facility designed to process the INEL's waste streams. These requirements are contained in five reports that discuss the following topics: (1) an environmental compliance plan and schedule, (2) National Environmental Policy Act requirements, (3) preliminary siting requirements, (4) regulatory justification for the project, and (5) health and safety criteria

  20. A common-sense probabilistic approach to assessing inadvertent human intrusion into low-level radioactive waste at the Nevada Test Site

    International Nuclear Information System (INIS)

    Black, P.; Hooten, M.; Black, K.; Moore, B.; Rawlinson, S.; Barker, L.

    1997-01-01

    Each site disposing of low-level radioactive waste is required to prepare and maintain a site-specific performance assessment (1) to determine potential risks posed by waste management systems to the public, and the environment, and (2) to compare these risks to established performance objectives. The DOE Nevada Operations Office, Waste Management Program recently completed a one-year study of site-specific scenarios for inadvertent human intrusion by drilling into buried low-level radioactive waste sites, as part of ongoing performance assessment studies. Intrusion scenarios focus on possible penetration of buried waste through drilling for sources of groundwater. The probability of drilling penetration into waste was judged to be driven primarily by two settlement scenarios: (1) scattered individual homesteaders, and (2) a community scenario consisting of a cluster of settlers that share drilling and distribution systems for groundwater. Management control factors include institutional control, site knowledge, placards and markers, surface barriers, and subsurface barriers. The Subject Matter Experts concluded that institutional control and site knowledge may be important factors for the first few centuries, but are not significant over the evaluation period of 10,000 years. Surface barriers can be designed that would deter the siting of a drill rig over the waste site to an effectiveness of 95%. Subsurface barriers and placards and markers will not as effectively prevent inadvertent human intrusion. Homestead and community scenarios were considered by the panel to render a site-specific probability of around 10% for inadvertent human intrusion. If management controls are designed and implemented effectively, then the probability of inadvertent human intrusion can be reduced to less than 1%

  1. Low-level effects

    International Nuclear Information System (INIS)

    Devine, R.T.; Chaput, R.L.

    1987-01-01

    Risk assignments can be made to given practices involving exposure to radiation, because sufficient data are available for the effects of high-dose, low-LET radiation and because sufficient exists in the methods of extrapolation to low doses and low dose rates. The confidence in the extrapolations is based on the fact that the risk is not expected to be overestimated, using the assumptions made (as opposed to the possibility that the extrapolations represent an accurate estimate of the risk). These risk estimates have been applied to the selection of permissible exposure levels, to show that various amounts of radiation involve no greater risk to the worker than the risk expected in another industry that is generally considered safe. The setting of standards for protection from exposure to low levels of ionizing radiation is made by expert committees at the national and international levels who weigh social factors as well as scientific factors. Data on low-level effects may be applied when assigning a ''probability of causation'' to a certain exposure of radiation. This has become a prominent method for arriving at an equitable award for damages caused by such exposure. The generation of these tables requires as many (if not more) social and political considerations as does the setting up of protection criteria. It is impossible to extract a purely scientific conclusion solely from the protection standards and other legal decisions. Sufficient information exists on low-LET radiation that safety standards for exposure can be rationally (if not scientifically) agreed upon

  2. A New Method for Processing Airborne Gamma Ray Spectrometry Data for Mapping Low Level Contaminations

    DEFF Research Database (Denmark)

    Aage, Helle Karina; Korsbech, Uffe C C; Bargholz, Kim

    1999-01-01

    A new technique for processing airborne gamma ray spectrometry data has been developed. It is based on the noise adjusted singular value decomposition method introduced by Hovgaard in 1997. The new technique opens for mapping of very low contamination levels. It is tested with data from Latvia...... where the remaining contamination from the 1986 Chernobyl accident together with fallout from the atmospheric nuclear weapon tests includes Cs-137 at levels often well below 1 kBq/m(2) equivalent surface contamination. The limiting factors for obtaining reliable results are radon in the air, spectrum...

  3. Neural Tuning to Low-Level Features of Speech throughout the Perisylvian Cortex.

    Science.gov (United States)

    Berezutskaya, Julia; Freudenburg, Zachary V; Güçlü, Umut; van Gerven, Marcel A J; Ramsey, Nick F

    2017-08-16

    Despite a large body of research, we continue to lack a detailed account of how auditory processing of continuous speech unfolds in the human brain. Previous research showed the propagation of low-level acoustic features of speech from posterior superior temporal gyrus toward anterior superior temporal gyrus in the human brain (Hullett et al., 2016). In this study, we investigate what happens to these neural representations past the superior temporal gyrus and how they engage higher-level language processing areas such as inferior frontal gyrus. We used low-level sound features to model neural responses to speech outside of the primary auditory cortex. Two complementary imaging techniques were used with human participants (both males and females): electrocorticography (ECoG) and fMRI. Both imaging techniques showed tuning of the perisylvian cortex to low-level speech features. With ECoG, we found evidence of propagation of the temporal features of speech sounds along the ventral pathway of language processing in the brain toward inferior frontal gyrus. Increasingly coarse temporal features of speech spreading from posterior superior temporal cortex toward inferior frontal gyrus were associated with linguistic features such as voice onset time, duration of the formant transitions, and phoneme, syllable, and word boundaries. The present findings provide the groundwork for a comprehensive bottom-up account of speech comprehension in the human brain. SIGNIFICANCE STATEMENT We know that, during natural speech comprehension, a broad network of perisylvian cortical regions is involved in sound and language processing. Here, we investigated the tuning to low-level sound features within these regions using neural responses to a short feature film. We also looked at whether the tuning organization along these brain regions showed any parallel to the hierarchy of language structures in continuous speech. Our results show that low-level speech features propagate throughout the

  4. Predicting Sentencing for Low-Level Crimes: Comparing Models of Human Judgment

    Science.gov (United States)

    von Helversen, Bettina; Rieskamp, Jorg

    2009-01-01

    Laws and guidelines regulating legal decision making are often imposed without taking the cognitive processes of the legal decision maker into account. In the case of sentencing, this raises the question of whether the sentencing decisions of prosecutors and judges are consistent with legal policy. Especially in handling low-level crimes, legal…

  5. Towards Smart Homes Using Low Level Sensory Data

    Directory of Open Access Journals (Sweden)

    Young-Koo Lee

    2011-12-01

    Full Text Available Ubiquitous Life Care (u-Life care is receiving attention because it provides high quality and low cost care services. To provide spontaneous and robust healthcare services, knowledge of a patient’s real-time daily life activities is required. Context information with real-time daily life activities can help to provide better services and to improve healthcare delivery. The performance and accuracy of existing life care systems is not reliable, even with a limited number of services. This paper presents a Human Activity Recognition Engine (HARE that monitors human health as well as activities using heterogeneous sensor technology and processes these activities intelligently on a Cloud platform for providing improved care at low cost. We focus on activity recognition using video-based, wearable sensor-based, and location-based activity recognition engines and then use intelligent processing to analyze the context of the activities performed. The experimental results of all the components showed good accuracy against existing techniques. The system is deployed on Cloud for Alzheimer’s disease patients (as a case study with four activity recognition engines to identify low level activity from the raw data captured by sensors. These are then manipulated using ontology to infer higher level activities and make decisions about a patient’s activity using patient profile information and customized rules.

  6. Low-level radioactive biomedical wastes

    International Nuclear Information System (INIS)

    Casarett, G.W.

    A summary of the management and hazards of low-level radioactive biomedical wastes is presented. The volume, disposal methods, current problems, regulatory agencies, and possible solutions to disposal problems are discussed. The benefits derived from using radioactivity in medicine are briefly described. Potential health risks are discussed. The radioactivity in most of the radioactive biomedical waste is a small fraction of that contained naturally in the human body or in the natural environment. Benefit-risk-cost considerations are presented. The cost of managing these wastes is getting so high that a new perspective for comparison of radioactivity (facts, risks, costs, benefits and trade-offs) and alternate approaches to minimize the risk and cost and maximize the benefits is suggested

  7. Low back pain and low level flying

    NARCIS (Netherlands)

    J.C.F.M. Aghina

    1989-01-01

    textabstractLow level flying is a very good tactical possibility to carry out a mission unseen by a hostile radarsystem. Nowadays, Western Europe in general and the Federal Republic of Germany in particular, decreased . the permissions to low level flying in assigned regions. That's why the

  8. Low-level Radioactivity Measurements

    International Nuclear Information System (INIS)

    Churtgen, C.

    2007-01-01

    The low-level radioactivity measurements service performs measurements of alpha or beta emitters on various types of low-radioactivity samples (biological and environmental) from internal and external clients. to maintain and develop techniques concerning the measurement of low-level radioactivity of alpha and beta emitting radionuclides in environmental or biological samples; to measure these samples by means of low-background counters (liquid scintillators, proportional counters, ZnS counters and alpha-spectrometers); to support and advise the nuclear and non-nuclear industry on problems of radioactive contamination or low level radioactivity measurements; to maintain the quality assurance system according to the ISO17025 standard for which we obtained the Beltest accreditation in 1998; to assess the internal dose from occupational intakes of radionuclides for workers of the nuclear industry;

  9. Responses to Human Bioeffluents at Levels Recommended by Ventilation Standards

    DEFF Research Database (Denmark)

    Zhang, Xiaojing; Wargocki, Pawel; Lian, Zhiwei

    2017-01-01

    The purpose of this study was to examine whether exposure to human bioeffluents, at the levels recommended by the current ventilation standards, would cause any effects on humans. Ten subjects were exposed in a low-emission stainless-steel climate chamber for 4.25 hours. The outdoor air supply rate...... was set to 33 or 4 l/s per person, creating two levels of bioeffluents with carbon dioxide (CO2) at 500 or 1600 ppm. Subjective ratings were collected, cognitive performance was examined and physiological responses were monitored. The results show that exposures to human bioeffluents at ventilation rate...

  10. National Low-Level Waste Management Program Radionuclide Report Series

    International Nuclear Information System (INIS)

    Rudin, M.J.; Garcia, R.S.

    1992-02-01

    This report, Volume 3 of the National Low-Level Radioactive Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of carbon-14. The report also discusses waste streams that contain carbon-14, waste forms that contain carbon-14, and carbon-14 behavior in the environment and in the human body

  11. Atmospheric polychlorinated biphenyls in Indian cities: Levels, emission sources and toxicity equivalents

    International Nuclear Information System (INIS)

    Chakraborty, Paromita; Zhang, Gan; Eckhardt, Sabine; Li, Jun; Breivik, Knut; Lam, Paul K.S.; Tanabe, Shinsuke; Jones, Kevin C.

    2013-01-01

    Atmospheric concentration of Polychlorinated biphenyls (PCBs) were measured on diurnal basis by active air sampling during Dec 2006 to Feb 2007 in seven major cities from the northern (New Delhi and Agra), eastern (Kolkata), western (Mumbai and Goa) and southern (Chennai and Bangalore) parts of India. Average concentration of Σ 25 PCBs in the Indian atmosphere was 4460 (±2200) pg/m −3 with a dominance of congeners with 4–7 chlorine atoms. Model results (HYSPLIT, FLEXPART) indicate that the source areas are likely confined to local or regional proximity. Results from the FLEXPART model show that existing emission inventories cannot explain the high concentrations observed for PCB-28. Electronic waste, ship breaking activities and dumped solid waste are attributed as the possible sources of PCBs in India. Σ 25 PCB concentrations for each city showed significant linear correlation with Toxicity equivalence (TEQ) and Neurotoxic equivalence (NEQ) values. Highlights: •Unlike decreasing trend of PCBs in United States and European countries, high levels of PCBs remain in the Indian atmosphere. •Existing emission inventories cannot explain the high PCB concentrations in Indian atmosphere. •Electronic waste recycling, ship dismantling and open burning of municipal solid waste are implicated as potential sources. -- Measurement of atmospheric Polychlorinated biphenyls in seven major Indian cities

  12. Low-level Radioactivity Measurements

    International Nuclear Information System (INIS)

    Hurtgen, C.

    2002-01-01

    The objectives of the research performed in the area of low-level radioactivity measurements are (1) to maintain and develop techniques for the measurement of low-level environmental and biological samples, (2) to measure these samples by means of low-background counters (liquid scintillators, proportional counters, ZnS counters, alpha spectrometry), (3) to support and advise the nuclear and non-nuclear industry on problems of radioactive contamination and low-level radioactivity measurements; (4) to maintain and improve the quality assurance system according to the ISO17025 standard; and (5) to assess the internal dose from occupational intakes of radionuclides of workers of the nuclear industry. Progress and achievements in these areas in 2001 are reported

  13. Low-level Radioactivity Measurements

    International Nuclear Information System (INIS)

    Hurtgen, C.

    2001-01-01

    The objectives of the research performed in the area of low-level radioactivity measurements are (1) to maintain and develop techniques for the measurement of low-level environmental and biological samples, (2) to measure these samples by means of low-background counters (liquid scintillators, proportional counters, ZnS counters, alpha spectrometry), (3) to support and advice the nuclear and non-nuclear industry in matters concerning radioactive contamination and/or low-level radioactivity measurements; (4) to maintain the quality assurance system according to the EN45001/ISO17025 standard; and (5) to assess the internal dose from occupational intakes of radionuclides of workers of the nuclear industry. Progress and achievements in these areas in 2000 are reported

  14. Long-chain omega-3 from low-trophic-level fish provides value to farmed seafood.

    Science.gov (United States)

    Bibus, Douglas M

    2015-03-01

    Low-trophic-level fish are a crucial source of long-chain (LC) omega-3 fatty acids for farmed fish and humans. Many farm-raised fish species have a clear need for these nutrients. Farmed fish deposit the LC omega-3s in their flesh and transfer them up the food chain. However, the content of LC omega-3s in farm-raised seafood continues to decline, while the content of shorter-chain plant-sourced omega-3s, and pro-inflammtory omega-6s continue to increase. This reduces its nutritional worth. The value of low-trophic-level fish is often viewed merely as its price at the dock. Some reports and metrics steer public attention towards the mass balance between quantities of low-trophic-level fish and farmed seafood. However, the the nutritional value of seafood is more important than its mere quantities. The role of low-trophic-level fish in human nutrition, health, and wellbeing is a fundamental component of its economic value to society.

  15. An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity & Extraterrestrial Fire-Safety Applications

    Science.gov (United States)

    Olson, S. L.; Beeson, H.; Haas, J.

    2001-01-01

    One of the performance goals for NASA's enterprise of Human Exploration and Development of Space (HEDS) is to develop methods, data bases, and validating tests for material flammability characterization, hazard reduction, and fire detection/suppression strategies for spacecraft and extraterrestrial habitats. This work addresses these needs by applying the fundamental knowledge gained from low stretch experiments to the development of a normal gravity low stretch material flammability test method. The concept of the apparatus being developed uses the low stretch geometry to simulate the conditions of the extraterrestrial environment through proper scaling of the sample dimensions to reduce the buoyant stretch in normal gravity. The apparatus uses controlled forced-air flow to augment the low stretch to levels which simulate Lunar or Martian gravity levels. In addition, the effect of imposed radiant heat flux on material flammability can be studied with the cone heater. After breadboard testing, the apparatus will be integrated into NASA's White Sands Test Facility's Atmosphere-Controlled Cone Calorimeter for evaluation as a new materials screening test method.

  16. National Low-Level Waste Management Program Radionuclide Report Series

    International Nuclear Information System (INIS)

    Rudin, M.J.; Garcia, R.S.

    1992-02-01

    This volume serves as an introduction to the National Low-Level Radioactive Waste Management Program Radionuclide Report Series. This report includes discussions of radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha-emitting transuranics with half-lives greater than five years). Each report includes information regarding radiological and chemical characteristics of specific radionuclides. Information is also included discussing waste streams and waste forms that may contain each radionuclide, and radionuclide behavior in the environment and in the human body. Not all radionuclides commonly found at low-level radioactive waste sites are included in this report. The discussion in this volume explains the rationale of the radionuclide selection process

  17. Construction and characterization of a yeast artificial chromosome library containing seven haploid human genome equivalents

    International Nuclear Information System (INIS)

    Albertsen, H.M.; Abderrahim, H.; Cann, H.M.; Dausset, J.; Le Paslier, D.; Cohen, D.

    1990-01-01

    Prior to constructing a library of yeast artificial chromosomes (YACs) containing very large human DNA fragments, the authors performed a series of preliminary experiments aimed at developing a suitable protocol. They found an inverse relationship between YAC insert size and transformation efficiency. Evidence of occasional rearrangement within YAC inserts was found resulting in clonally stable internal deletions or clonally unstable size variations. A protocol was developed for preparative electrophoretic enrichment of high molecular mass human DNA fragments from partial restriction digests and ligation with the YAC vector in agarose. A YAC library has been constructed from large fragments of DNA from an Epstein-Barr virus-transformed human lymphoblastoid cell line. The library presently contains 50,000 clones, 95% of which are greater than 250 kilobase pairs in size. The mean YAC size of the library, calculated from 132 randomly isolated clones, is 430 kilobase pairs. The library thus contains the equivalent of approximately seven haploid human genomes

  18. Low level waste repositories

    International Nuclear Information System (INIS)

    Hill, P.R.H.; Wilson, M.A.

    1983-11-01

    Factors in selecting a site for low-level radioactive waste disposal are discussed. South Australia has used a former tailings dam in a remote, arid location as a llw repository. There are also low-level waste disposal procedures at the Olympic Dam copper/uranium project

  19. Inactivated H7 Influenza Virus Vaccines Protect Mice despite Inducing Only Low Levels of Neutralizing Antibodies.

    Science.gov (United States)

    Kamal, Ram P; Blanchfield, Kristy; Belser, Jessica A; Music, Nedzad; Tzeng, Wen-Pin; Holiday, Crystal; Burroughs, Ashley; Sun, Xiangjie; Maines, Taronna R; Levine, Min Z; York, Ian A

    2017-10-15

    Avian influenza viruses of the H7 hemagglutinin (HA) subtype present a significant public health threat, as evidenced by the ongoing outbreak of human A(H7N9) infections in China. When evaluated by hemagglutination inhibition (HI) and microneutralization (MN) assays, H7 viruses and vaccines are found to induce lower level of neutralizing antibodies (nAb) than do their seasonal counterparts, making it difficult to develop and evaluate prepandemic vaccines. We have previously shown that purified recombinant H7 HA appear to be poorly immunogenic in that they induce low levels of HI and MN antibodies. In this study, we immunized mice with whole inactivated reverse genetics reassortant (RG) viruses expressing HA and neuraminidase (NA) from 3 different H7 viruses [A/Shanghai/2/2013(H7N9), A/Netherlands/219/2003(H7N7), and A/New York/107/2003(H7N2)] or with human A(H1N1)pdm09 (A/California/07/2009-like) or A(H3N2) (A/Perth16/2009) viruses. Mice produced equivalent titers of antibodies to all viruses as measured by enzyme-linked immunosorbent assay (ELISA). However, the antibody titers induced by H7 viruses were significantly lower when measured by HI and MN assays. Despite inducing very low levels of nAb, H7 vaccines conferred complete protection against homologous virus challenge in mice, and the serum antibodies directed against the HA head region were capable of mediating protection. The apparently low immunogenicity associated with H7 viruses and vaccines may be at least partly related to measuring antibody titers with the traditional HI and MN assays, which may not provide a true measure of protective immunity associated with H7 immunization. This study underscores the need for development of additional correlates of protection for prepandemic vaccines. IMPORTANCE H7 avian influenza viruses present a serious risk to human health. Preparedness efforts include development of prepandemic vaccines. For seasonal influenza viruses, protection is correlated with antibody

  20. Effect of Temperature, Pressure and Equivalence Ratio on Ignition Delay in Ignition Quality Tester (IQT): Diesel,n-Heptane, andiso-Octane Fuels under Low Temperature Conditions

    KAUST Repository

    Yang, Seung Yeon

    2015-11-02

    Effects of temperature, pressure and global equivalence ratio on total ignition delay time in a constant volume spray combustion chamber were investigated for diesel fuel along with the primary reference fuels (PRFs) of n-heptane and iso-octane in relatively low temperature conditions to simulate unsteady spray ignition behavior. A KAUST Research ignition quality tester (KR-IQT) was utilized, which has a feature of varying temperature, pressure and equivalence ratio using a variable displacement fuel pump. A gradient method was adopted in determining the start of ignition in order to compensate pressure increase induced by low temperature heat release. Comparison of this method with other existing methods was discussed. Ignition delay times were measured at various equivalence ratios (0.5-1.7) with the temperatures of initial charge air in the range from 698 to 860 K and the pressures in the range of 1.5 to 2.1 MPa, pertinent to low temperature combustion (LTC) conditions. An attempt to scale the effect of pressure on total ignition delay was undertaken and the equivalence ratio exponent and activation energy in the Arrhenius expression of total ignition delay were determined. Ignition delay results indicated that there were strong correlations of pressure, temperature, and equivalence ratio under most conditions studied except at relatively low pressures. Diesel (DCN 52.5) and n-heptane (DCN 54) fuels exhibited reasonably similar ignition delay characteristics, while iso-octane showed a distinct behavior under low temperature regime having a two-stage ignition, which substantiate the adoption of the gradient method in determining ignition delay.

  1. 41 CFR 102-80.105 - What information must be included in an equivalent level of safety analysis?

    Science.gov (United States)

    2010-07-01

    ... REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level.... Each analysis should describe potential reasonable worst case fire scenarios and their impact on the... and location of fuel items, space layout, building construction, openings and ventilation, suppression...

  2. National Low-Level Waste Management Program Radionuclide Report Series

    International Nuclear Information System (INIS)

    Rudin, M.J.; Stanton, C.; Patterson, R.G.; Garcia, R.S.

    1992-02-01

    This report, Volume 2 of the National Low-Level Radioactive Waste Management Program Radionuclide Report Series, discusses radiological and chemical characteristics of technetium-99. This report also includes discussions about waste streams in which technetium-99 can be found, waste forms that contain technetium-99, and technetium-99's behavior in the environment and in the human body

  3. Tree-level equivalence between a Lorentz-violating extension of QED and its dual model in electron-electron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Toniolo, Giuliano R.; Fargnoli, H.G.; Brito, L.C.T. [Universidade Federal de Lavras, Departamento de Fisica, Caixa Postal 3037, Lavras, Minas Gerais (Brazil); Scarpelli, A.P.B. [Setor Tecnico-Cientifico, Departamento de Policia Federal, Sao Paulo (Brazil)

    2017-02-15

    S-matrix amplitudes for the electron-electron scattering are calculated in order to verify the physical equivalence between two Lorentz-breaking dual models. We begin with an extended Quantum Electrodynamics which incorporates CPT-even Lorentz-violating kinetic and mass terms. Then, in a process of gauge embedding, its gauge-invariant dual model is obtained. The physical equivalence of the two models is established at tree level in the electron-electron scattering and the unpolarized cross section is calculated up to second order in the Lorentz-violating parameter. (orig.)

  4. Tree-level equivalence between a Lorentz-violating extension of QED and its dual model in electron-electron scattering

    International Nuclear Information System (INIS)

    Toniolo, Giuliano R.; Fargnoli, H.G.; Brito, L.C.T.; Scarpelli, A.P.B.

    2017-01-01

    S-matrix amplitudes for the electron-electron scattering are calculated in order to verify the physical equivalence between two Lorentz-breaking dual models. We begin with an extended Quantum Electrodynamics which incorporates CPT-even Lorentz-violating kinetic and mass terms. Then, in a process of gauge embedding, its gauge-invariant dual model is obtained. The physical equivalence of the two models is established at tree level in the electron-electron scattering and the unpolarized cross section is calculated up to second order in the Lorentz-violating parameter. (orig.)

  5. Low magnesium level

    Science.gov (United States)

    Low magnesium level is a condition in which the amount of magnesium in the blood is lower than normal. The medical ... that convert or use energy ( metabolism ). When the level of magnesium in the body drops below normal, ...

  6. On the genetic effects of low-level tritium

    International Nuclear Information System (INIS)

    Hori, Tada-aka; Nakai, Sayaka

    1976-01-01

    Genetic risk assessment for potential hazard from environmental tritium to man becomes important with increasing nuclear-power industry. The purpose of this short review is to discuss the possible genetic effects of tritium from a view of genetic risk estimation. The discussion is based mainly on our experimental results on the chromosome aberrations induced in human lymphocytes by tritium at the very low-level. The types of chromosome aberrations induced by radiation from tritium incorporated into the cells are mostly chromatid types. The most interesting finding is that the dose-response relationship observed in both tritiated-water and tritiated-thymidine is composed of two phases. The examination on the nature of two-phase dose-response relationship is very important not only for the mechanisms of chromosome aberrations, but also for the evaluation of genetic risk from low-level radiation. (auth.)

  7. Scenarios of the TWRS low-level waste disposal program

    International Nuclear Information System (INIS)

    1994-10-01

    As a result of past Department of Energy (DOE) weapons material production operations, Hanford now stores nuclear waste from processing facilities in underground tanks on the 200 Area plateau. An agreement between the DOE, the Environmental Protection Agency (EPA), and the Washington state Department of Ecology (the Tri-Party Agreement, or TPA) establishes an enforceable schedule and a technical framework for recovering, processing, solidifying, and disposing of the Hanford tank wastes. The present plan includes retrieving the tank waste, pretreating the waste to separate into low level and high level streams, and converting both streams to a glass waste form. The low level glass will represent by far the largest volume and lowest quantity of radioactivity (i.e., large volume of waste chemicals) of waste requiring disposal. The low level glass waste will be retrievably stored in sub-surface disposal vaults for several decades. If the low level disposal system proves to be acceptable, the disposal site will be closed with the low level waste in place. If, however, at some time the disposal system is found to be unacceptable, then the waste can be retrieved and dealt with in some other manner. WHC is planning to emplace the waste so that it is retrievable for up to 50 years after completion of the tank waste processing. Acceptability of disposal of the TWRS low level waste at Hanford depends on technical, cultural, and political considerations. The Performance Assessment is a major part of determining whether the proposed disposal action is technically defensible. A Performance Assessment estimates the possible future impact to humans and the environment for thousands of years into the future. In accordance with the TPA technical strategy, WHC plans to design a near-surface facility suitable for disposal of the glass waste

  8. The radiobiology of boron neutron capture therapy: Are ''photon-equivalent'' doses really photon-equivalent?

    International Nuclear Information System (INIS)

    Coderre, J.A.; Diaz, A.Z.; Ma, R.

    2001-01-01

    Boron neutron capture therapy (BNCT) produces a mixture of radiation dose components. The high-linear energy transfer (LET) particles are more damaging in tissue than equal doses of low-LET radiation. Each of the high-LET components can multiplied by an experimentally determined factor to adjust for the increased biological effectiveness and the resulting sum expressed in photon-equivalent units (Gy-Eq). BNCT doses in photon-equivalent units are based on a number of assumptions. It may be possible to test the validity of these assumptions and the accuracy of the calculated BNCT doses by 1) comparing the effects of BNCT in other animal or biological models where the effects of photon radiation are known, or 2) if there are endpoints reached in the BNCT dose escalation clinical trials that can be related to the known response to photons of the tissue in question. The calculated Gy-Eq BNCT doses delivered to dogs and to humans with BPA and the epithermal neutron beam of the Brookhaven Medical Research Reactor were compared to expected responses to photon irradiation. The data indicate that Gy-Eq doses in brain may be underestimated. Doses to skin are consistent with the expected response to photons. Gy-Eq doses to tumor are significantly overestimated. A model system of cells in culture irradiated at various depths in a lucite phantom using the epithermal beam is under development. Preliminary data indicate that this approach can be used to detect differences in the relative biological effectiveness of the beam. The rat 9L gliosarcoma cell survival data was converted to photon-equivalent doses using the same factors assumed in the clinical studies. The results superimposed on the survival curve derived from irradiation with Cs-137 photons indicating the potential utility of this model system. (author)

  9. Measurement of cardiopulmonary performance during acute exposure to a 2440-m equivalent atmosphere

    Science.gov (United States)

    Levitan, B. M.; Bungo, M. W.

    1982-01-01

    Each of 20 subjects (ranging in age from 18 to 38 years, 15 being male, five female) was given two Bruce Protocol symptom-limited maximum treadmill stress tests, breathing sea-level compressed air (20.9% O2) for one test and a 2440-m equivalent (15.5% O2) for the other. A significant difference was found to exist between measured VO2 max (p less than 0.0002) and exercise time (p less than 0.0004) for the two conditions. No significant differences were observed in heart rate or the recovery time to a respiratory quotient of less than 1. Hemoglobin saturation, as measured by an ear oximeter, averaged 95% for sea-level and 91% for the 2440-m equivalent gases. These results support a 2440-m equivalent contingency atmosphere in the Space Shuttle prior to donning a low-pressure suit for the purpose reducing nitrogen washout times.

  10. Shelf-life evaluation of bilayered human skin equivalent, MyDerm™.

    Directory of Open Access Journals (Sweden)

    Wan Tai Seet

    Full Text Available Skin plays an important role in defense against infection and other harmful biological agents. Due to its fragile structure, skin can be easily damaged by heat, chemicals, traumatic injuries and diseases. An autologous bilayered human skin equivalent, MyDerm™, was engineered to provide a living skin substitute to treat critical skin loss. However, one of the disadvantages of living skin substitute is its short shelf-life, hence limiting its distribution worldwide. The aim of this study was to evaluate the shelf-life of MyDerm™ through assessment of cell morphology, cell viability, population doubling time and functional gene expression levels before transplantation. Skin samples were digested with 0.6% Collagenase Type I followed by epithelial cells dissociation with TrypLE Select. Dermal fibroblasts and keratinocytes were culture-expanded to obtain sufficient cells for MyDerm™ construction. MyDerm™ was constructed with plasma-fibrin as temporary biomaterial and evaluated at 0, 24, 48 and 72 hours after storage at 4°C for its shelf-life determination. The morphology of skin cells derived from MyDerm™ remained unchanged across storage times. Cells harvested from MyDerm™ after storage appeared in good viability (90.5%±2.7% to 94.9%±1.6% and had short population doubling time (58.4±8.7 to 76.9±19 hours. The modest drop in cell viability and increased in population doubling time at longer storage duration did not demonstrate a significant difference. Gene expression for CK10, CK14 and COL III were also comparable between different storage times. In conclusion, MyDerm™ can be stored in basal medium at 4°C for at least 72 hours before transplantation without compromising its functionality.

  11. Shelf-life evaluation of bilayered human skin equivalent, MyDerm™.

    Science.gov (United States)

    Seet, Wan Tai; Manira, Maarof; Maarof, Manira; Khairul Anuar, Khairoji; Chua, Kien-Hui; Ahmad Irfan, Abdul Wahab; Ng, Min Hwei; Aminuddin, Bin Saim; Ruszymah, Bt Hj Idrus

    2012-01-01

    Skin plays an important role in defense against infection and other harmful biological agents. Due to its fragile structure, skin can be easily damaged by heat, chemicals, traumatic injuries and diseases. An autologous bilayered human skin equivalent, MyDerm™, was engineered to provide a living skin substitute to treat critical skin loss. However, one of the disadvantages of living skin substitute is its short shelf-life, hence limiting its distribution worldwide. The aim of this study was to evaluate the shelf-life of MyDerm™ through assessment of cell morphology, cell viability, population doubling time and functional gene expression levels before transplantation. Skin samples were digested with 0.6% Collagenase Type I followed by epithelial cells dissociation with TrypLE Select. Dermal fibroblasts and keratinocytes were culture-expanded to obtain sufficient cells for MyDerm™ construction. MyDerm™ was constructed with plasma-fibrin as temporary biomaterial and evaluated at 0, 24, 48 and 72 hours after storage at 4°C for its shelf-life determination. The morphology of skin cells derived from MyDerm™ remained unchanged across storage times. Cells harvested from MyDerm™ after storage appeared in good viability (90.5%±2.7% to 94.9%±1.6%) and had short population doubling time (58.4±8.7 to 76.9±19 hours). The modest drop in cell viability and increased in population doubling time at longer storage duration did not demonstrate a significant difference. Gene expression for CK10, CK14 and COL III were also comparable between different storage times. In conclusion, MyDerm™ can be stored in basal medium at 4°C for at least 72 hours before transplantation without compromising its functionality.

  12. Operation of gas electron multiplier (GEM) with propane gas at low pressure and comparison with tissue-equivalent gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    De Nardo, L., E-mail: laura.denardo@unipd.it [University of Padova, Physics and Astronomy Department and PD-INFN, via Marzolo 8, I-35131 Padova (Italy); Farahmand, M., E-mail: majid.farahmand@rivm.nl [Centre for Environmental Safety and Security, National Institute for Public Health and the Environment (RIVM), PO Box 1, NL-3720 BA Bilthoven (Netherlands)

    2016-05-21

    A Tissue-Equivalent Proportional Counter (TEPC), based on a single GEM foil of standard geometry, has been tested with pure propane gas at low pressure, in order to simulate a tissue site of about 1 µm equivalent size. In this work, the performance of GEM with propane gas at a pressure of 21 and 28 kPa will be presented. The effective gas gain was measured in various conditions using a {sup 244}Cm alpha source. The dependence of effective gain on the electric field strength along the GEM channel and in the drift and induction region was investigated. A maximum effective gain of about 5×10{sup 3} has been reached. Results obtained in pure propane gas are compared with gas gain measurements in gas mixtures commonly employed in microdosimetry, that is propane and methane based Tissue-Equivalent gas mixtures.

  13. Photoprotection by pistachio bioactives in a 3-dimensional human skin equivalent tissue model.

    Science.gov (United States)

    Chen, C-Y Oliver; Smith, Avi; Liu, Yuntao; Du, Peng; Blumberg, Jeffrey B; Garlick, Jonathan

    2017-09-01

    Reactive oxygen species (ROS) generated during ultraviolet (UV) light exposure can induce skin damage and aging. Antioxidants can provide protection against oxidative injury to skin via "quenching" ROS. Using a validated 3-dimensional (3D) human skin equivalent (HSE) tissue model that closely mimics human skin, we examined whether pistachio antioxidants could protect HSE against UVA-induced damage. Lutein and γ-tocopherol are the predominant lipophilic antioxidants in pistachios; treatment with these compounds prior to UVA exposure protected against morphological changes to the epithelial and connective tissue compartments of HSE. Pistachio antioxidants preserved overall skin thickness and organization, as well as fibroblast morphology, in HSE exposed to UVA irradiation. However, this protection was not substantiated by the analysis of the proliferation of keratinocytes and apoptosis of fibroblasts. Additional studies are warranted to elucidate the basis of these discordant results and extend research into the potential role of pistachio bioactives promoting skin health.

  14. Packaged low-level waste verification system

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, K.; Winberg, M.R.; McIsaac, C.V. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1995-12-31

    The Department of Energy through the National Low-Level Waste Management Program and WMG Inc. have entered into a joint development effort to design, build, and demonstrate the Packaged Low-Level Waste Verification System. Currently, states and low-level radioactive waste disposal site operators have no method to independently verify the radionuclide content of packaged low-level waste that arrives at disposal sites for disposition. At this time, the disposal site relies on the low-level waste generator shipping manifests and accompanying records to ensure that low-level waste received meets the site`s waste acceptance criteria. The subject invention provides the equipment, software, and methods to enable the independent verification of low-level waste shipping records to ensure that the site`s waste acceptance criteria are being met. The objective of the prototype system is to demonstrate a mobile system capable of independently verifying the content of packaged low-level waste.

  15. Controlling low-level radioactive waste

    International Nuclear Information System (INIS)

    1990-01-01

    This series of information sheets describes at a popular level the sources of low-level radioactive wastes, their associated hazards, methods of storage, transportation and disposal, and the Canadian regulations that cover low-level wastes

  16. Radiation safety and health effects related to low-level radioactive wastes

    International Nuclear Information System (INIS)

    King, W.C.

    1979-01-01

    The hazards associated with low-level radioactive waste, one of the nation's greatest concerns, are discussed from a health physicist's perspective. Potential biological hazards, four stages of the low-level radioactive waste disposal process, and suggested methods of reducing the risks of handling and disposal, based on previous studies, are defined. Also discussed are potential pathways of human exposure and two scenarios designed to demonstrate the complexity of modeling exposure pathways. The risks of developing a fatal cancer from exposure to the radioactive material, should it occur, is compared to other more commonly accepted risks

  17. Two meals with different carbohydrate, fat and protein contents render equivalent postprandial plasma levels of calprotectin, cortisol, triglycerides and zonulin.

    Science.gov (United States)

    Ohlsson, Bodil; Darwiche, Gassan; Roth, Bodil; Höglund, Peter

    2016-11-01

    The aim was to compare postprandial plasma levels of calprotectin, cortisol, triglycerides and zonulin between a control breakfast and a moderately low-carbohydrate test breakfast, given randomly after 10-h fast. Blood samples were collected before and repeatedly after the meal. Plasma calprotectin, cortisol, triglycerides and zonulin were analyzed. The total area under the curve (tAUC) and change in AUC from baseline (dAUC) were calculated. Ratios between the test and control values were calculated to investigate equivalence. Healthy volunteers (8 men and 12 women; 46.0 ± 14.5 years) were included. tAUCs of cortisol and triglycerides did not differ between the breakfasts (p = 0.158 versus p = 0.579). Cortisol dAUCs were decreased and triglyceride dAUCs were increased after both breakfasts, with no differences between the breakfasts (p = 0.933 versus p = 0.277). Calprotectin and zonulin levels were unaffected. The meals were bioequivalent for cortisol, triglycerides and zonulin, but not for calprotectin.

  18. What happens at very low levels of radiation exposure ? Are the low dose exposures beneficial ?

    International Nuclear Information System (INIS)

    Deniz, Dalji

    2006-01-01

    Full text: Radiation is naturally present in our environment and has been since the birth of this planet. The human population is constantly exposed to low levels of natural background radiation, primarily from environmental sources, and to higher levels from occupational sources, medical therapy, and other human-mediated events. Radiation is one of the best-investigated hazardous agents. The biological effects of ionizing radiation for radiation protection consideration are grouped into two categories: The deterministic and the stochastic ones. Deterministic radiation effects can be clinically diagnosed in the exposed individual and occur when above a certain t hreshold a n appropriately high dose is absorbed in the tissues and organs to cause the death of a large number of cells and consequently to impair tissue or organ functions early after exposure. A clinically observable biological effect (Acute Radiation Sendromes, ARS) occurs days to months after an acute radiation dose. Stochastic radiation effects are the chronic effects of radiation result from relatively low exposure levels delivered over long periods of time. These are sort of effects that might result from occupational exposure, or to the background exposure levels. Such late effects might be the development of malignant (cancerous) disease and of the hereditary consequences. These effects may be observed many years after the radiation exposure. There is a latent period between the initial radiation exposure and the development of the biological effect. For this reason, a stochastic effect is called a Linear or Zero-Threshold (LNT) Dose-Response Effect. There is a stochastic correlation between the number of cases of cancers or genetic defects developed inside a population and the dose received by the population at relatively large levels of radiation. These changes in gene activation seem to be able to modify the response of cells to subsequent radiation exposure, termed the a daptive response

  19. Design and construction of low level radioactive waste disposal facility at Rokkasho storage center

    International Nuclear Information System (INIS)

    Takahashi, K.; Itoh, H.; Iimura, H.; Shimoda, H.

    1992-01-01

    Japan Nuclear Fuel Industries Co., Inc. (JNFI) which has been established to dispose through burial the low-level radioactive waste (LLW) produced by nuclear power stations over the country is now constructing Rokkasho LLW Storage Center at Rokkasho Village,Aomori Prefecture. At this storage center JNFI plans to bury about 200,000m 3 , of LLW (equivalent to about one million drums each with a 200 liter capacity), and ultimately plans to bury about 600,000m 3 about 3 million drums of LLW. About the construction of the burial facilities for the first-stage LLW equivalent to 200,000 drums (each with a 200-liter capacity) we obtained the government's permit in November, 1990 and set out the construction work from the same month, which has since been promoted favorably. The facilities are scheduled to start operation from December, 1992. This paper gives an overview of at these facilities

  20. Low-risk susceptibility alleles in 40 human breast cancer cell lines

    International Nuclear Information System (INIS)

    Riaz, Muhammad; Elstrodt, Fons; Hollestelle, Antoinette; Dehghan, Abbas; Klijn, Jan GM; Schutte, Mieke

    2009-01-01

    Low-risk breast cancer susceptibility alleles or SNPs confer only modest breast cancer risks ranging from just over 1.0 to1.3 fold. Yet, they are common among most populations and therefore are involved in the development of essentially all breast cancers. The mechanism by which the low-risk SNPs confer breast cancer risks is currently unclear. The breast cancer association consortium BCAC has hypothesized that the low-risk SNPs modulate expression levels of nearby located genes. Genotypes of five low-risk SNPs were determined for 40 human breast cancer cell lines, by direct sequencing of PCR-amplified genomic templates. We have analyzed expression of the four genes that are located nearby the low-risk SNPs, by using real-time RT-PCR and Human Exon microarrays. The SNP genotypes and additional phenotypic data on the breast cancer cell lines are presented. We did not detect any effect of the SNP genotypes on expression levels of the nearby-located genes MAP3K1, FGFR2, TNRC9 and LSP1. The SNP genotypes provide a base line for functional studies in a well-characterized cohort of 40 human breast cancer cell lines. Our expression analyses suggest that a putative disease mechanism through gene expression modulation is not operative in breast cancer cell lines

  1. Determination of no-observed effect level (NOEL-biomarker equivalents to interpret biomonitoring data for organophosphorus pesticides in children

    Directory of Open Access Journals (Sweden)

    Bouchard Michèle

    2009-02-01

    Full Text Available Abstract Background Environmental exposure to organophosphorus pesticides has been characterized in various populations, but interpretation of these data from a health risk perspective remains an issue. The current paper proposes biological reference values to help interpret biomonitoring data related to an exposure to organophosphorus pesticides in children for which measurements of alkylphosphate metabolites are available. Methods Published models describing the kinetics of malathion and chlorpyrifos in humans were used to determine no-observed effect level – biomarker equivalents for methylphosphates and ethylphosphates, respectively. These were expressed in the form of cumulative urinary amounts of alkylphosphates over specified time periods corresponding to an absorbed no-observed effect level dose (derived from a published human exposure dose and assuming various plausible exposure scenarios. Cumulative amounts of methylphosphate and ethylphosphate metabolites measured in the urine of a group of Quebec children were then compared to the proposed biological reference values. Results From a published no-observed effect level dose for malathion and chlorpyrifos, the model predicts corresponding oral biological reference values for methylphosphate and ethylphosphate derivatives of 106 and 52 nmol/kg of body weight, respectively, in 12-h nighttime urine collections, and dermal biological reference values of 40 and 32 nmol/kg of body weight. Out of the 442 available urine samples, only one presented a methylphosphate excretion exceeding the biological reference value established on the basis of a dermal exposure scenario and none of the methylphosphate and ethylphosphate excretion values were above the obtained oral biological reference values, which reflect the main exposure route in children. Conclusion This study is a first step towards the development of biological guidelines for organophophorus pesticides using a toxicokinetic modeling

  2. Sensitivity to the visual field origin of natural image patches in human low-level visual cortex

    Directory of Open Access Journals (Sweden)

    Damien J. Mannion

    2015-06-01

    Full Text Available Asymmetries in the response to visual patterns in the upper and lower visual fields (above and below the centre of gaze have been associated with ecological factors relating to the structure of typical visual environments. Here, we investigated whether the content of the upper and lower visual field representations in low-level regions of human visual cortex are specialised for visual patterns that arise from the upper and lower visual fields in natural images. We presented image patches, drawn from above or below the centre of gaze of an observer navigating a natural environment, to either the upper or lower visual fields of human participants (n = 7 while we used functional magnetic resonance imaging (fMRI to measure the magnitude of evoked activity in the visual areas V1, V2, and V3. We found a significant interaction between the presentation location (upper or lower visual field and the image patch source location (above or below fixation; the responses to lower visual field presentation were significantly greater for image patches sourced from below than above fixation, while the responses in the upper visual field were not significantly different for image patches sourced from above and below fixation. This finding demonstrates an association between the representation of the lower visual field in human visual cortex and the structure of the visual input that is likely to be encountered below the centre of gaze.

  3. National low-level waste management program radionuclide report series, Volume 15: Uranium-238

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-09-01

    This report, Volume 15 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of uranium-238 ( 238 U). The purpose of the National Low-Level Waste Management Program Radionuclide Report Series is to provide information to state representatives and developers of low-level radioactive waste disposal facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the waste disposal facility environment. This report also includes discussions about waste types and forms in which 238 U can be found, and 238 U behavior in the environment and in the human body

  4. Serum metabolome biomarkers associate low-level environmental perfluorinated compound exposure with oxidative /nitrosative stress in humans.

    Science.gov (United States)

    Wang, Xiaofei; Liu, Liangpo; Zhang, Weibing; Zhang, Jie; Du, Xiaoyan; Huang, Qingyu; Tian, Meiping; Shen, Heqing

    2017-10-01

    Previous in vivo and in vitro studies have linked perfluorinated compound (PFC) exposure with metabolic interruption, but the inter-species difference and high treatment doses usually make the results difficult to be extrapolated to humans directly. The best strategy for identifying the metabolic interruption may be to establish the direct correlations between monitored PFCs data and metabolic data on human samples. In this study, serum metabolome data and PFC concentrations were acquired for a Chinese adult male cohort. The most abundant PFCs are PFOA and PFOS with concentration medians 7.56 and 12.78 nM, respectively; in together they count around 81.6% of the total PFCs. PFC concentration-related serum metabolic profile changes and the related metabolic biomarkers were explored by using partial least squares-discriminant analysis (PLS-DA). Respectively taking PFOS, PFOA and total PFC as the classifiers, serum metabolome can be differentiated between the lowest dose group (1st quartile PFCs) and the highest PFC dose group (4th quartile PFCs). Ten potential PFC biomarkers were identified, mainly involving in pollutant detoxification, antioxidation and nitric oxide (NO) signal pathways. These suggested that low-level environmental PFC exposure has significantly adverse impacts on glutathione (GSH) cycle, Krebs cycle, nitric oxide (NO) generation and purine oxidation in humans. To the best of our knowledge, this is the first report investigating the association of environmental PFC exposure with human serum metabolome alteration. Given the important biological functions of the identified biomarkers, we suggest that PFC could increase the metabolism syndromes risk including diabetes and cardiovascular diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Simulation-Based Prediction of Equivalent Continuous Noises during Construction Processes.

    Science.gov (United States)

    Zhang, Hong; Pei, Yun

    2016-08-12

    Quantitative prediction of construction noise is crucial to evaluate construction plans to help make decisions to address noise levels. Considering limitations of existing methods for measuring or predicting the construction noise and particularly the equivalent continuous noise level over a period of time, this paper presents a discrete-event simulation method for predicting the construction noise in terms of equivalent continuous level. The noise-calculating models regarding synchronization, propagation and equivalent continuous level are presented. The simulation framework for modeling the noise-affected factors and calculating the equivalent continuous noise by incorporating the noise-calculating models into simulation strategy is proposed. An application study is presented to demonstrate and justify the proposed simulation method in predicting the equivalent continuous noise during construction. The study contributes to provision of a simulation methodology to quantitatively predict the equivalent continuous noise of construction by considering the relevant uncertainties, dynamics and interactions.

  6. Assessment of penetration of quantum dots through in vitro and in vivo human skin using the human skin equivalent model and the tape stripping method

    International Nuclear Information System (INIS)

    Jeong, Sang Hoon; Kim, Jae Hwan; Yi, Sang Min; Lee, Jung Pyo; Kim, Jin Ho; Sohn, Kyung Hee; Park, Kui Lea; Kim, Meyoung-Kon; Son, Sang Wook

    2010-01-01

    Quantum dots (QDs) are rapidly emerging as an important class of nanoparticles (NPs) with potential applications in medicine. However, little is known about penetration of QDs through human skin. This study investigated skin penetration of QDs in both in vivo and in vitro human skin. Using the tape stripping method, this study demonstrates for the first time that QDs can actually penetrate through the stratum corneum (SC) of human skin. Transmission electron microscope (TEM) and energy diverse X-ray (EDX) analysis showed accumulation of QDs in the SC of a human skin equivalent model (HSEM) after dermal exposure to QDs. These findings suggest possible transdermal absorption of QDs after dermal exposure over a relatively long period of time.

  7. The control of superluminal group velocity in a system equivalent to the Y-type four-level atomic system

    International Nuclear Information System (INIS)

    Li Luming; Guo Hong; Xiao Feng; Peng Xiang; Chen Xuzong

    2005-01-01

    We study a new way to control the superluminal group velocity of light pulse in hot atomic gases with the five-level atomic configuration. The model of an equivalent Y-type four-level is applied and shows that the light goes faster by using an additional incoherent pumping field. The experiment is performed and shows in good agreement with our theoretical predictions

  8. Low-level-waste-treatment handbook

    International Nuclear Information System (INIS)

    Clinton, S.D.; Goeller, H.E.; Holladay, D.W.; Donaldson, T.L.

    1982-01-01

    The initial draft of the Low-Level Waste Treatment Handbook has been prepared and submitted to the DOE Low-Level Waste Management Program for review and comment. A revised draft is scheduled to be delivered to DOE Headquarters in December 1982. The Handbook is designed to be useful to all individuals and groups concerned with low-level wastes. It is one of several volumes that will ultimately comprise a Low-Level Waste Technology Handbook. The objective of the Low-Level Waste Treatment Handbook is to present an overview of current practices related to the segregation, classification, volume reduction, solidification, handling, packaging, and transportation of LLW for disposal in a shallow land burial facility. The Handbook is intended to serve as a guide to individuals interested in the treatment and handling of low-level radioactive waste. The Handbook will not explicitly tell the user how to design and operate LLW treatment facilities, but rather will identify (1) kinds of information required to evaluate the options, (2) methods that may be used to evaluate these options, and (3) limitations associated with the selection of the treatment options. The focus of the Handbook is providing guidance on how to do waste treatment for disposal by shallow land burial

  9. Losses Approximation for Soft Magnetic Composites Based on a Homogenized Equivalent Conductivity

    Directory of Open Access Journals (Sweden)

    X. Ren

    2016-09-01

    Full Text Available Soft magnetic composites (SMC are a promising alternative to laminated steel in many Electrical Engineering applications. This is largely owing to their low level of eddy current losses. The electromagnetic behavior of SMC in electromagnetic devices cannot be easily predicted using standard numerical techniques such as the finite element method, mostly due to the computational cost required to model the material microstructure. Another difficulty lies in the high property contrast between the matrix and the inclusions. In this paper we propose a homogenization strategy to define the equivalent electromagnetic properties of SMC. For components made of SMC, the equivalent conductivity and permeability can be determined. These equivalent properties can be used to calculate eddy current losses or introduced into structural analysis tools to design electromagnetic devices.

  10. Assessment of permissible low-level releases of radionuclides into the marine environment

    International Nuclear Information System (INIS)

    Kryshev, I.I.; Sazykina, T.G.

    2002-01-01

    The subject of this paper is radio-ecological assessment of permissible low-level releases of radionuclides in sea waters ensuring the radiological protection of the human population, as well as marine biota. (author)

  11. Operation for Rokkasho Low Level Radioactive Waste Disposal Center

    International Nuclear Information System (INIS)

    Kamizono, Hideki

    2008-01-01

    The Rokkasho Low Level Radioactive Waste (LLW) Disposal Center is located in Oishitai, Rokkasho-mura, Kamikitagun, of Aomori Prefecture. This district is situated in the southern part of Shimohita Peninsula in the northeastern corner of the prefecture, which lies at the northern tip of Honshu, Japan's main island. The Rokkasho LLW Disposal Center deals with only LLW generated by operating of nuclear power plants. The No.1 and No.2 disposal facility are now in operation. The disposal facilities in operation have a total dispose capacity of 80,000m 3 (equivalent to 400,000 drums). Our final business scope is to dispose of radioactive waste corresponding to 600,000 m 3 (equivalent to 3000,000 drums). For No.1 disposal facility, we have been disposing of homogeneous waste, including condensed liquid waste, spent resin, solidified with cement and asphalt, etc. For No.2 disposal facility, we can bury a solid waste solidified with mortar, such as activated metals and plastics, etc. Using an improved construction technology for an artificial barrier, the concrete pits in No.2 disposal facility could be constructed more economical and spacious than that of No.1. Both No.1 and No.2 facility will be able to bury about 200,000 waste packages (drums) each corresponding to 40,000 m 3 . As of March 17, 2008, Approximately 200,00 waste drums summing up No.1 and No.2 disposal facility have been received from Nuclear power plants and buried. (author)

  12. Low level waste disposal

    International Nuclear Information System (INIS)

    Barthoux, A.

    1985-01-01

    Final disposal of low level wastes has been carried out for 15 years on the shallow land disposal of the Manche in the north west of France. Final participant in the nuclear energy cycle, ANDRA has set up a new waste management system from the production center (organization of the waste collection) to the disposal site including the setting up of a transport network, the development of assessment, additional conditioning, interim storage, the management of the disposal center, records of the location and characteristics of the disposed wastes, site selection surveys for future disposals and a public information Department. 80 000 waste packages representing a volume of 20 000 m 3 are thus managed and disposed of each year on the shallow land disposal. The disposal of low level wastes is carried out according to their category and activity level: - in tumuli for very low level wastes, - in monoliths, a concrete structure, of the packaging does not provide enough protection against radioactivity [fr

  13. Transportation and disposal configuration for DOE-managed low-level and mixed low-level waste

    International Nuclear Information System (INIS)

    Johnsen, T.

    1993-06-01

    This report briefly examines the current U.S. Department of Energy complex-wide configuration for transportation and disposal of low-level and mixed low-level waste, and also retraces the historical sequence of events and rationale that has guided its development. The study determined that Nevada Test Site and the Hanford Site are the only two sites that currently provide substantial disposal services for offsite low-level waste generators. It was also determined that mixed low-level waste shipments are infrequent and are generally limited to shipments to offsite commercial treatment facilities or other Department of Energy sites for storage. The current alignment of generator to disposal site for low-level waste shipments is generally consistent with the programmatic mission of the generator; that is, defense-generated waste is shipped to the Nevada Test Site and research-generated waste is transported to the Hanford Site. The historical development of the current configuration was resurrected by retrieving Department of Energy documentation and interviewing both current and former department and contractor personnel. According to several accounts, the basic framework of the system was developed during the late 1970s, and was reportedly based on the ability of the disposal site to manage a given waste form. Documented evidence to support this reasoning, however, could not be uncovered

  14. Assumed genetic effects of low level irradiation on man

    International Nuclear Information System (INIS)

    Dutrillaux, B.

    1976-01-01

    The significance of human genetic pathology is stated and a study is made of the assumed effect of low level ionizing radiations. The theoretical notions thus derived are compared to experimental data which are poor. A quick survey of the literature shows that is has not yet been possible to establish a direct relationship between an increase of exposure and any genetic effect on man. However, this must not lead to conclude on the innoxiousness of radiation but rather shows how such analyses are difficult in as much as the effect investigated is necessarily low [fr

  15. Assessment of the in vitro dermal irritation potential of cerium, silver, and titanium nanoparticles in a human skin equivalent model

    Science.gov (United States)

    AbstractDermal exposure to metals may res·ult in irritant contact dermatitis. This study examined the potential of metal nanoparticles to elicit irritant contact dermatitis in a human skin equivalent model (HSEM) derived from epidermal keratinocytes. These cultured cells form a m...

  16. Fractal feature of sEMG from Flexor digitorum superficialis muscle correlated with levels of contraction during low-level finger flexions.

    Science.gov (United States)

    Arjunan, Sridhar P; Kumar, Dinesh K; Naik, Ganesh R

    2010-01-01

    This research paper reports an experimental study on identification of the changes in fractal properties of surface Electromyogram (sEMG) with the changes in the force levels during low-level finger flexions. In the previous study, the authors have identified a novel fractal feature, Maximum fractal length (MFL) as a measure of strength of low-level contractions and has used this feature to identify various wrist and finger movements. This study has tested the relationship between the MFL and force of contraction. The results suggest that changes in MFL is correlated with the changes in contraction levels (20%, 50% and 80% maximum voluntary contraction (MVC)) during low-level muscle activation such as finger flexions. From the statistical analysis and by visualisation using box-plot, it is observed that MFL (p ≈ 0.001) is a more correlated to force of contraction compared to RMS (p≈0.05), even when the muscle contraction is less than 50% MVC during low-level finger flexions. This work has established that this fractal feature will be useful in providing information about changes in levels of force during low-level finger movements for prosthetic control or human computer interface.

  17. A visible Chinese human-combined Monte Carlo simulation study on low-level light therapy of stroke

    Science.gov (United States)

    Wang, Pengbo; Pan, Boan; Zhong, Fulin; Li, Ting

    2017-02-01

    Stroke is a devastating disease, which is the third leading cause of death and disability worldwide. Although the incidence of stroke increases progressively with age, morbidity among young and middle-aged adults is increasing annually. Medications nevertheless remain the bulwarks of stroke. The treatment is ineffective, speculative and has a long treatment cycle. The function of acupuncture and moxibustion, which are potential therapeutic tools for stroke, is still controversial. Recently, Low-level light therapy (LLLT) has been demonstrated potent in vivo efficacy for treatment of ischemic conditions of acute myocardial infraction and stroke in multiple validated animal models. Optimum LLLT treatment has a dominant influence on therapy of stroke. While more than a thousand clinical trials have been halted, only a few trials on animals have been reported. We addressed this issue by simulating near-infrared light propagation with accurate visible Chinese human head by Monte Carlo modeling. The visible human head embody region of atherosclerotic plaques in head. Through comparing the light propagation of different light illumination, we can get a precise, optimized and straightforward treatment. Here, we developed a LLLT helmet for treating stroke depend on near-infrared light. There are more than 30 LED arrays in in multi-layered 3D printed helmet. Each LED array has independent water-cooling module and can be adjusted to touch the head of different subjects based on Electro pneumatic module. Moreover, the software provides the setup of illumination parameters and 3D distribution of light fluence rate distribution in human brain.

  18. Decompositional equivalence: A fundamental symmetry underlying quantum theory

    OpenAIRE

    Fields, Chris

    2014-01-01

    Decompositional equivalence is the principle that there is no preferred decomposition of the universe into subsystems. It is shown here, by using simple thought experiments, that quantum theory follows from decompositional equivalence together with Landauer's principle. This demonstration raises within physics a question previously left to psychology: how do human - or any - observers agree about what constitutes a "system of interest"?

  19. Oxidized low density lipoprotein increases RANKL level in human vascular cells. Involvement of oxidative stress

    Energy Technology Data Exchange (ETDEWEB)

    Mazière, Cécile, E-mail: maziere.cecile@chu-amiens.fr [Biochemistry Laboratory, South Hospital University, René Laennec Avenue, Amiens 80000 (France); Salle, Valéry [Internal Medicine, North Hospital University, Place Victor Pauchet, Amiens 80000 (France); INSERM U1088 (EA 4292), SFR CAP-Santé (FED 4231), University of Picardie – Jules Verne (France); Gomila, Cathy; Mazière, Jean-Claude [Biochemistry Laboratory, South Hospital University, René Laennec Avenue, Amiens 80000 (France)

    2013-10-18

    Highlights: •Oxidized LDL enhances RANKL level in human smooth muscle cells. •The effect of OxLDL is mediated by the transcription factor NFAT. •UVA, H{sub 2}O{sub 2} and buthionine sulfoximine also increase RANKL level. •All these effects are observed in human fibroblasts and endothelial cells. -- Abstract: Receptor Activator of NFκB Ligand (RANKL) and its decoy receptor osteoprotegerin (OPG) have been shown to play a role not only in bone remodeling but also in inflammation, arterial calcification and atherosclerotic plaque rupture. In human smooth muscle cells, Cu{sup 2+}-oxidized LDL (CuLDL) 10–50 μg/ml increased reactive oxygen species (ROS) and RANKL level in a dose-dependent manner, whereas OPG level was not affected. The lipid extract of CuLDL reproduced the effects of the whole particle. Vivit, an inhibitor of the transcription factor NFAT, reduced the CuLDL-induced increase in RANKL, whereas PKA and NFκB inhibitors were ineffective. LDL oxidized by myeloperoxidase (MPO-LDL), or other pro-oxidant conditions such as ultraviolet A (UVA) irradiation, incubation with H{sub 2}O{sub 2} or with buthionine sulfoximine (BSO), an inhibitor of glutathione synthesis{sub ,} also induced an oxidative stress and enhanced RANKL level. The increase in RANKL in pro-oxidant conditions was also observed in fibroblasts and endothelial cells. Since RANKL is involved in myocardial inflammation, vascular calcification and plaque rupture, this study highlights a new mechanism whereby OxLDL might, by generation of an oxidative stress, exert a deleterious effect on different cell types of the arterial wall.

  20. Low-level stored waste inspection using mobile robots

    International Nuclear Information System (INIS)

    Byrd, J.S.; Pettus, R.O.

    1996-01-01

    A mobile robot inspection system, ARIES (Autonomous Robotic Inspection Experimental System), has been developed for the U.S. Department of Energy to replace human inspectors in the routine, regulated inspection of radioactive waste stored in drums. The robot will roam the three-foot aisles of drums, stacked four high, making decisions about the surface condition of the drums and maintaining a database of information about each drum. A distributed system of onboard and offboard computers will provide versatile, friendly control of the inspection process. This mobile robot system, based on a commercial mobile platform, will improve the quality of inspection, generate required reports, and relieve human operators from low-level radioactive exposure. This paper describes and discusses primarily the computer and control processes for the system

  1. Equivalence classification by California sea lions using class-specific reinforcers.

    OpenAIRE

    Kastak, C R; Schusterman, R J; Kastak, D

    2001-01-01

    The ability to group dissimilar stimuli into categories on the basis of common stimulus relations (stimulus equivalence) or common functional relations (functional equivalence) has been convincingly demonstrated in verbally competent subjects. However, there are investigations with verbally limited humans and with nonhuman animals that suggest that the formation and use of classification schemes based on equivalence does not depend on linguistic skills. The present investigation documented th...

  2. Derivation of a reference dose and drinking water equivalent level for 1,2,3-trichloropropane.

    Science.gov (United States)

    Tardiff, Robert G; Carson, M Leigh

    2010-06-01

    In some US potable water supplies, 1,2,3-trichloropropane (TCP) has been present at ranges of non-detect to less than 100 ppb, resulting from past uses. In subchronic oral studies, TCP produced toxicity in kidneys, liver, and other tissues. TCP administered by corn oil gavage in chronic studies produced tumors at multiple sites in rats and mice; however, interpretation of these studies was impeded by substantial premature mortality. Drinking water equivalent levels (DWELs) were estimated for a lifetime of consumption by applying biologically-based safety/risk assessment approaches, including Monte Carlo techniques, and with consideration of kinetics and modes of action, to possibly replace default assumptions. Internationally recognized Frameworks for human relevance of animal data were employed to interpret the findings. Calculated were a reference dose (=39 microg/kg d) for non-cancer and Cancer Values (CV) (=10-14 microg/kg d) based on non-linear dose-response relationships for mutagenicity as a precursor of cancer. Lifetime Average Daily Intakes (LADI) are 3130 and 790-1120 microg/person-d for non-cancer and cancer, respectively. DWELs, estimated by applying a relative source contribution (RSC) of 50% to the LADIs, are 780 and 200-280 microg/L for non-cancer and cancer, respectively. These DWELs may inform establishment of formal/informal guidelines and standards to protect public health. Copyright 2010 Elsevier Ltd. All rights reserved.

  3. Low-level waste program technical strategy

    International Nuclear Information System (INIS)

    Bledsoe, K.W.

    1994-01-01

    The Low-Level Waste Technical Strategy document describes the mechanisms which the Low-Level Waste Program Office plans to implement to achieve its mission. The mission is to manage the receipt, immobilization, packaging, storage/disposal and RCRA closure (of the site) of the low-level Hanford waste (pretreated tank wastes) in an environmentally sound, safe and cost-effective manner. The primary objective of the TWRS Low-level waste Program office is to vitrify the LLW fraction of the tank waste and dispose of it onsite

  4. A proposed alternative approach for protection of inadvertent human intruders from buried Department of Energy low level radioactive wastes

    International Nuclear Information System (INIS)

    Cochran, J.R.

    1995-01-01

    The burial of radioactive wastes creates a legacy. To limit the impact of this legacy on future generations, we establish and comply with performance objectives. This paper reviews performance objectives for the long-term isolation of buried radioactive wastes; identifies regulatorly-defined performance objectives for protecting the inadvertent human intruder (IHI) from buried low-level radioactive waste (LLW); (3) discusses a shortcoming of the current approach; and (4) offers an alternative approach for protecting the IHI. This alternative approach is written specifically for the burial of US Department of Energy (DOE) wastes at the Nevada Test Site (NTS), although the approach might be applied at other DOE burial sites

  5. The equivalence of a human observer and an ideal observer in binary diagnostic tasks

    Science.gov (United States)

    He, Xin; Samuelson, Frank; Gallas, Brandon D.; Sahiner, Berkman; Myers, Kyle

    2013-03-01

    The Ideal Observer (IO) is "ideal" for given data populations. In the image perception process, as the raw images are degraded by factors such as display and eye optics, there is an equivalent IO (EIO). The EIO uses the statistical information that exits the perception/cognitive degradations as the data. We assume a human observer who received sufficient training, e.g., radiologists, and hypothesize that such a human observer can be modeled as if he is an EIO. To measure the likelihood ratio (LR) distributions of an EIO, we formalize experimental design principles that encourage rationality based on von Neumann and Morgenstern's (vNM) axioms. We present examples to show that many observer study design refinements, although motivated by empirical principles explicitly, implicitly encourage rationality. Our hypothesis is supported by a recent review paper on ROC curve convexity by Pesce, Metz, and Berbaum. We also provide additional evidence based on a collection of observer studies in medical imaging. EIO theory shows that the "sub-optimal" performance of a human observer can be mathematically formalized in the form of an IO, and measured through rationality encouragement.

  6. Influences of engineered barrier systems on low-level radioactive waste disposal

    International Nuclear Information System (INIS)

    Buckley, L.P.

    1987-09-01

    There are major differences between the current practices of shallow land burial and alternative concepts for the disposal of low-level radioactive wastes. Additional protection provided with engineered barrier systems can overcome major concerns the public has with shallow land burial: subsidence; percolating ground waters; radionuclide migration; and the vulnerability of shallow trenches to intrusion. The presence of a variety of engineered barriers to restrict water movement, retain radionuclides and to prevent plant animal or human intrusion leads to significant changes to input data for performance assessment models. Several programs which are underway to more accurately predict the long-term performance of engineered barriers for low-level waste will be described

  7. Influences of engineered barrier systems on low-level radioactive waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, L. P.

    1987-09-15

    There are major differences between the current practices of shallow land burial and alternative concepts for the disposal of low-level radioactive wastes. Additional protection provided with engineered barrier systems can overcome major concerns the public has with shallow land burial: subsidence; percolating ground waters; radionuclide migration; and the vulnerability of shallow trenches to intrusion. The presence of a variety of engineered barriers to restrict water movement, retain radionuclides and to prevent plant animal or human intrusion leads to significant changes to input data for performance assessment models. Several programs which are underway to more accurately predict the long-term performance of engineered barriers for low-level waste will be described.

  8. National Low-Level Waste Management Program radionuclide report series. Volume 2, Niobium-94

    International Nuclear Information System (INIS)

    Adams, J.P.; Carboneau, M.L.

    1995-04-01

    The Purpose of the National Low-Level Waste Management Program Radionuclide Report Series is to provide information to, state representatives and developers of low-level radioactive waste disposal facilities about the radiological chemical, and physical characteristics of selected radionuclides and their behavior in the low-level radioactive waste disposal facility environment. Extensive surveys of available literature provided information used to produce this series of reports and an introductory report. This report is Volume 11 of the series. It outlines the basic radiological, chemical, and physical characteristics of niobium-94, waste types and forms that contain it, and its behavior in environmental media such as soils, plants, groundwater, air, animals and the human body

  9. Development of biomonitoring equivalents for barium in urine and plasma for interpreting human biomonitoring data.

    Science.gov (United States)

    Poddalgoda, Devika; Macey, Kristin; Assad, Henry; Krishnan, Kannan

    2017-06-01

    The objectives of the present work were: (1) to assemble population-level biomonitoring data to identify the concentrations of urinary and plasma barium across the general population; and (2) to derive biomonitoring equivalents (BEs) for barium in urine and plasma in order to facilitate the interpretation of barium concentrations in the biological matrices. In population level biomonitoring studies, barium has been measured in urine in the U.S. (NHANES study), but no such data on plasma barium levels were identified. The BE values for plasma and urine were derived from U.S. EPA's reference dose (RfD) of 0.2 mg/kg bw/d, based on a lower confidence limit on the benchmark dose (BMDL 05 ) of 63 mg/kg bw/d. The plasma BE (9 μg Ba/L) was derived by regression analysis of the near-steady-state plasma concentrations associated with the administered doses in animals exposed to barium chloride dihydrate in drinking water for 2-years in a NTP study. Using a human urinary excretion fraction of 0.023, a BE for urinary barium (0.19 mg/L or 0.25 mg/g creatinine) was derived for US EPA's RfD. The median and the 95 th percentile barium urine concentrations of the general population in U.S. are below the BE determined in this study, indicating that the population exposure to inorganic barium is expected to be below the exposure guidance value of 0.2 mg/kg bw/d. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  10. Distortion-product otoacoustic emission at low frequencies in humans

    DEFF Research Database (Denmark)

    Christensen, Anders Tornvig

    -frequency hearing has not yet been characterized by measurement of low-frequency emissions from the cochlea. Low-frequency emissions are expected to be covered in sounds of breathing, blood circulation, and so on, if they exist at all at measurable levels. The present study shows, in essence, that the human ear...... emits distortion at least 1-2 octaves lower in frequency than has previously been shown. The emission is promising for further exploratory and clinical assessment of cochlear activity associated with low-frequency hearing. Anders received his M.Sc. degree in acoustics in 2012 from Aalborg University...

  11. Low potassium level

    Science.gov (United States)

    ... treat and prevent low level of potassium. These foods include: Avocados Baked potato Bananas Bran Carrots Cooked lean beef Milk Oranges Peanut butter Peas and beans Salmon Seaweed Spinach Tomatoes Wheat germ

  12. Directions in low-level radioactive waste management: A brief history of commercial low-level radioactive waste disposal

    International Nuclear Information System (INIS)

    1990-10-01

    This report presents a history of commercial low-level radioactive waste management in the United States, with emphasis on the history of six commercially operated low-level radioactive waste disposal facilities. The report includes a brief description of important steps that have been taken during the 1980s to ensure the safe disposal of low-level waste in the 1990s and beyond. These steps include the issuance of Title 10 Code of Federal Regulations Part 61, Licensing Requirements for the Land Disposal of Radioactive Waste, the Low-Level Radioactive Waste Policy Act of 1980, the Low-Level Radioactive Waste Policy Amendments Act of 1985, and steps taken by states and regional compacts to establish additional disposal sites. 42 refs., 13 figs., 1 tab

  13. National Low-Level Waste Management Program Radionuclide Report Series. Volume 10, Nickel-63

    International Nuclear Information System (INIS)

    Carboneau, M.L.; Adams, J.P.

    1995-02-01

    This report outlines the basic radiological, chemical, and physical characteristics of nickel-63 ( 63 Ni) and examines how these characteristics affect the behavior of 63 Ni in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of 63 Ni production, waste types, and waste forms that contain 63 Ni. The primary source of 63 Ni in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable 62 Ni that is present in the structural components of nuclear reactor vessels. 63 Ni enters the environment from the dismantling activities associated with nuclear reactor decommissioning. However, small amounts of 63 Ni have been detected in the environment following the testing of thermonuclear weapons in the South Pacific. Concentrations as high as 2.7 Bq a per gram of sample (or equivalently 0.0022 parts per billion) were observed on Bikini Atoll (May 1954). 63 Ni was not created as a fission product species (e.g., from 235 U or 239 Pu fissions), but instead was produced as a result of neutron capture in 63 Ni, a common nickel isotope present in the stainless steel components of nuclear weapons (e.g., stainless-304 contains ∼9% total Ni or ∼0.3% 63 Ni)

  14. The monetary value of the collective dose equivalent unit (person-rem)

    International Nuclear Information System (INIS)

    Rodgers, Reginald C.

    1978-01-01

    In the design and operation of nuclear power reactor facilities, it is recommended that radiation exposures to the workers and the general public be kept as 'low as reasonably achievable' (ALARA). In the process of implementing this principle cost-benefit evaluations are part of the decision making process. For this reason a monetary value has to be assigned to the collective dose equivalent unit (person-rem). The various factors such as medical health care, societal penalty and manpower replacement/saving are essential ingredients to determine a monetary value for the person-rem. These factors and their dependence on the level of risk (or exposure level) are evaluated. Monetary values of well under $100 are determined for the public dose equivalent unit. The occupational worker person-rem value is determined to be in the range of $500 to about $5000 depending on the exposure level and the type of worker and his affiliation, i.e., temporary or permanent. A discussion of the variability and the range of the monetary values will be presented. (author)

  15. Calculation of W for low energy electrons in tissue-equivalent gas. [<10 keV

    Energy Technology Data Exchange (ETDEWEB)

    Dayashankar, [Bhabha Atomic Research Centre, Bombay (India). Div. of Radiation Protection

    1977-11-01

    The mean energy expended per ion pair formed (W-value) in the tissue-equivalent gas for incident electrons of energy up to 10 keV has been calculated in the continuous slowing-down approximation. The effect of secondary and tertiary electrons has been considered by utilizing recent measurements of Opal et al., (1971, J. Chem. Phys., 55,4100) on the energy spectra of low-energy secondary electrons and the Mott formula for the spectra of high-energy secondaries. The results, which are provisional in nature due to the limitations on the accuracy of the input cross-section data and the neglect of the discrete nature of energy loss process, are compared with the available measurements.

  16. MUTZ-3 derived Langerhans cells in human skin equivalents show differential migration and phenotypic plasticity after allergen or irritant exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kosten, Ilona J.; Spiekstra, Sander W. [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Gruijl, Tanja D. de [Department of Dermatology Medical Oncology, VU University Medical Center, Amsterdam (Netherlands); Gibbs, Susan, E-mail: s.gibbs@acta.nl [Department of Dermatology, VU University Medical Center, Amsterdam (Netherlands); Department of Oral Cell Biology, Academic Center for Dentistry (ACTA), Amsterdam (Netherlands)

    2015-08-15

    After allergen or irritant exposure, Langerhans cells (LC) undergo phenotypic changes and exit the epidermis. In this study we describe the unique ability of MUTZ-3 derived Langerhans cells (MUTZ-LC) to display similar phenotypic plasticity as their primary counterparts when incorporated into a physiologically relevant full-thickness skin equivalent model (SE-LC). We describe differences and similarities in the mechanisms regulating LC migration and plasticity upon allergen or irritant exposure. The skin equivalent consisted of a reconstructed epidermis containing primary differentiated keratinocytes and CD1a{sup +} MUTZ-LC on a primary fibroblast-populated dermis. Skin equivalents were exposed to a panel of allergens and irritants. Topical exposure to sub-toxic concentrations of allergens (nickel sulfate, resorcinol, cinnamaldehyde) and irritants (Triton X-100, SDS, Tween 80) resulted in LC migration out of the epidermis and into the dermis. Neutralizing antibody to CXCL12 blocked allergen-induced migration, whereas anti-CCL5 blocked irritant-induced migration. In contrast to allergen exposure, irritant exposure resulted in cells within the dermis becoming CD1a{sup −}/CD14{sup +}/CD68{sup +} which is characteristic of a phenotypic switch of MUTZ-LC to a macrophage-like cell in the dermis. This phenotypic switch was blocked with anti-IL-10. Mechanisms previously identified as being involved in LC activation and migration in native human skin could thus be reproduced in the in vitro constructed skin equivalent model containing functional LC. This model therefore provides a unique and relevant research tool to study human LC biology in situ under controlled in vitro conditions, and will provide a powerful tool for hazard identification, testing novel therapeutics and identifying new drug targets. - Highlights: • MUTZ-3 derived Langerhans cells integrated into skin equivalents are fully functional. • Anti-CXCL12 blocks allergen-induced MUTZ-LC migration.

  17. Attainment of radiation equivalency principle

    International Nuclear Information System (INIS)

    Shmelev, A.N.; Apseh, V.A.

    2004-01-01

    Problems connected with the prospects for long-term development of the nuclear energetics are discussed. Basic principles of the future large-scale nuclear energetics are listed, primary attention is the safety of radioactive waste management of nuclear energetics. The radiation equivalence principle means close of fuel cycle and management of nuclear materials transportation with low losses on spent fuel and waste processing. Two aspects are considered: radiation equivalence in global and local aspects. The necessity of looking for other strategies of fuel cycle management in full-scale nuclear energy on radioactive waste management is supported [ru

  18. Environmental monitoring of low-level radioactive materials

    International Nuclear Information System (INIS)

    Jester, W.A.; Yu, C.

    1985-01-01

    The authors discuss some of the current rationale behind the environmental monitoring of low-level radioactive materials are as follows: Committee 4 of the International commission on Radiological Protection (ICRP) defined three broad objectives for environmental monitoring: 1) assessment of the actual or potential exposure of humans to radioactive materials or radiation present in their environment or the estimation of the probable upper limits of such exposure; 2) scientific investigation, sometimes related to the assessment of exposures, sometimes to other objectives; 3) improved public relations. Various regulations have been written requiring environmental monitoring to ensure that the public is not being exposed to excessive amounts of radiation from natural sources or from human activities. An example of the monitoring of natural sources of radiation is a requirement of the Environmental Protection Agency's (EPA) National Interim Primary Drinking Water Regulations whereby U.S. water supply companies must have drinking water monitored at least once every four years for radionuclides, primarily the naturally occurring radium-226

  19. Human capital in low-tech manufacturing

    DEFF Research Database (Denmark)

    Hansen, Teis; Winther, Lars; Hansen, Ronnie Fibæk

    2014-01-01

    An essential feature associated with the rise of the knowledge economy has been the increasing focus on the importance of human capital as a precondition for economic growth. Human capital has been found to have a positive impact on the economic growth of high-tech industries, however, the influe......An essential feature associated with the rise of the knowledge economy has been the increasing focus on the importance of human capital as a precondition for economic growth. Human capital has been found to have a positive impact on the economic growth of high-tech industries, however......, the influence of human capital on the development of low-tech industries is yet to be analysed. This paper provides such an examination of low-tech industries based on an analysis of employment data within manufacturing industries in Denmark in the period 1993–2006. The findings highlight, first, that human...... capital appears to be equally important for economic development in low-tech industries and, second, that the divide between the large urban regions, especially Copenhagen, and the rest of the country plays the primary role in explaining the geography of human capital. These findings stress the relevance...

  20. Directions in low-level radioactive waste management: A brief history of commercial low-level radioactive waste disposal

    International Nuclear Information System (INIS)

    1994-08-01

    This report presents a history of commercial low-level radioactive waste disposal in the United States, with emphasis on the history of six commercially operated low-level radioactive waste disposal facilities. The report includes a brief description of important steps that have been taken during the last decade to ensure the safe disposal of low-level radioactive waste in the 1990s and beyond. These steps include the issuance of comprehensive State and Federal regulations governing the disposal of low-level radioactive waste, and the enactment of Federal laws making States responsible for the disposal of such waste generated within their borders

  1. A first vascularized skin equivalent as an alternative to animal experimentation.

    Science.gov (United States)

    Groeber, Florian; Engelhardt, Lisa; Lange, Julia; Kurdyn, Szymon; Schmid, Freia F; Rücker, Christoph; Mielke, Stephan; Walles, Heike; Hansmann, Jan

    2016-01-01

    Tissue-engineered skin equivalents mimic key aspects of the human skin, and can thus be employed as wound coverage for large skin defects or as in vitro test systems as an alternative to animal models. However, current skin equivalents lack a functional vasculature limiting clinical and research applications. This study demonstrates the generation of a vascularized skin equivalent with a perfused vascular network by combining a biological vascularized scaffold (BioVaSc) based on a decellularized segment of a porcine jejunum and a tailored bioreactor system. Briefly, the BioVaSc was seeded with human fibroblasts, keratinocytes, and human microvascular endothelial cells. After 14 days at the air-liquid interface, hematoxylin & eosin and immunohistological staining revealed a specific histological architecture representative of the human dermis and epidermis including a papillary-like architecture at the dermal-epidermal-junction. The formation of the skin barrier was measured non-destructively using impedance spectroscopy. Additionally, endothelial cells lined the walls of the formed vessels that could be perfused with a physiological volume flow. Due to the presence of a complex in-vivo-like vasculature, the here shown skin equivalent has the potential for skin grafting and represents a sophisticated in vitro model for dermatological research.

  2. Development of a tissue-engineered human oral mucosa equivalent based on an acellular allogeneic dermal matrix: a preliminary report of clinical application to burn wounds.

    Science.gov (United States)

    Iida, Takuya; Takami, Yoshihiro; Yamaguchi, Ryo; Shimazaki, Shuji; Harii, Kiyonori

    2005-01-01

    Tissue-engineered skin equivalents composed of epidermal and dermal components have been widely investigated for coverage of full-thickness skin defects. We developed a tissue-engineered oral mucosa equivalent based on an acellular allogeneic dermal matrix and investigated its characteristics. We also tried and assessed its preliminary clinical application. Human oral mucosal keratinocytes were separated from a piece of oral mucosa and cultured in a chemically-defined medium. The keratinocytes were seeded on to the acellular allogeneic dermal matrix and cultured. Histologically, the mucosa equivalent had a well-stratified epithelial layer. Immunohistochemical study showed that it was similar to normal oral mucosa. We applied this equivalent in one case with an extensive burn wound. The equivalent was transplanted three weeks after the harvest of the patient's oral mucosa and about 30% of the graft finally survived. We conclude that this new oral mucosa equivalent could become a therapeutic option for the treatment of extensive burns.

  3. Genetic damage from low-level and natural background radiation

    International Nuclear Information System (INIS)

    Oftedal, P.

    1988-01-01

    Relevant predictions that have been made of possible low level biological effects on man are reviewed, and the estimate of genetic damage is discussed. It is concluded that in spite of a number of attempts, no clear-cut case of effects in human populations of radiation at natural levels has been demonstrated. The stability of genetic material is dynamic, with damage, repair and selection running as continuous processes. Genetic materials are well protected and are conservative in the extreme, not least because evolution by genetic adaptation is an expensive process: Substitution of one allele A 1 by another A 2 means the death of the whole A 1 population

  4. Performance assessment methodology (PAM) for low level radioactive waste (LLRW) disposal facilities

    International Nuclear Information System (INIS)

    Selander, W.N.

    1992-01-01

    An overview is given for Performance Assessment Methodology (PAM) for Low Level Radioactive Waste (LLRW) disposal technologies, as required for licensing and safety studies. This is a multi-disciplinary activity, emphasizing applied mathematics, mass transfer, geohydrology and radiotoxicity effects on humans. (author). 2 refs

  5. Neural tuning to low-level features of speech throughout the perisylvian cortex

    NARCIS (Netherlands)

    Berezutskaya, Y.; Freudenburg, Z.V.; Güçlü, U.; Gerven, M.A.J. van; Ramsey, N.F.

    2017-01-01

    Despite a large body of research, we continue to lack a detailed account of how auditory processing of continuous speech unfolds in the human brain. Previous research showed the propagation of low-level acoustic features of speech from posterior superior temporal gyrus towards anterior superior

  6. Neural tuning to low-level features of speech throughout the perisylvian cortex

    NARCIS (Netherlands)

    Berezutskaya, Julia; Freudenburg, Zachary V.; Güçlü, Umut; van Gerven, Marcel A.J.; Ramsey, Nick F.

    2017-01-01

    Despite a large body of research, we continue to lack a detailed account of how auditory processing of continuous speech unfolds in the human brain. Previous research showed the propagation of low-level acoustic features of speech from posterior superior temporal gyrus toward anterior superior

  7. Effect of low and chronic radiation exposure to human population: Kollam study

    International Nuclear Information System (INIS)

    Ghosh, Anu; Kumar, Vinay

    2018-01-01

    Understanding the cellular and biological processes with low-level chronic radiation provides a rational basis for limits of exposure for occupational workers and general public. There are several high level natural radiation areas (HLNRA) of the world where human population is continuously exposed to natural radiation higher than the global average of 2.4 mGy/y. These areas provide unique opportunities to conduct studies which can provide better understanding of radiation effects and underlying mechanisms. The ∼55 km long monazite bearing belt of Kerala on the south-west coast of India is one such area. Over the last few decades, Bhabha Atomic Research Centre (BARC) has conducted extensive research on the human population residing in these areas to understand effects of low dose at the organismal, cellular and molecular levels. More recently, high resolution quantitative proteomic analysis of PBMCs using iTRAQ based LC-MS/MS identified differential expression of 1570 proteins in HLNRA individuals relative to individuals from the adjoining Normal Level Natural Radiation Areas (NLNRA). Almost 215 biological processes were distinctly altered in HLNRA samples, which included several pro-survival stress activated protein kinases and DNA repair networks. Many of the changes seen at the proteomics level were confirmed at the gene level using microarray expression data. This suggests an enhanced level of basal repair mechanisms in HLNRA individuals. The scientific program at BARC thus, focuses on fundamental scientific understanding of the mechanisms cells use to sense, repair and adapt to low dose radiation. Implications of these cellular processes for low dose radiation risk estimation will be discussed. (author)

  8. Thermally assisted OSL application for equivalent dose estimation; comparison of multiple equivalent dose values as well as saturation levels determined by luminescence and ESR techniques for a sedimentary sample collected from a fault gouge

    Energy Technology Data Exchange (ETDEWEB)

    Şahiner, Eren, E-mail: sahiner@ankara.edu.tr; Meriç, Niyazi, E-mail: meric@ankara.edu.tr; Polymeris, George S., E-mail: gspolymeris@ankara.edu.tr

    2017-02-01

    Highlights: • Multiple equivalent dose estimations were carried out. • Additive ESR and regenerative luminescence were applied. • Preliminary SAR results employing TA-OSL signal were discussed. • Saturation levels of ESR and luminescence were investigated. • IRSL{sub 175} and SAR TA-OSL stand as very promising for large doses. - Abstract: Equivalent dose estimation (D{sub e}) constitutes the most important part of either trap-charge dating techniques or dosimetry applications. In the present work, multiple, independent equivalent dose estimation approaches were adopted, using both luminescence and ESR techniques; two different minerals were studied, namely quartz as well as feldspathic polymineral samples. The work is divided into three independent parts, depending on the type of signal employed. Firstly, different D{sub e} estimation approaches were carried out on both polymineral and contaminated quartz, using single aliquot regenerative dose protocols employing conventional OSL and IRSL signals, acquired at different temperatures. Secondly, ESR equivalent dose estimations using the additive dose procedure both at room temperature and at 90 K were discussed. Lastly, for the first time in the literature, a single aliquot regenerative protocol employing a thermally assisted OSL signal originating from Very Deep Traps was applied for natural minerals. Rejection criteria such as recycling and recovery ratios are also presented. The SAR protocol, whenever applied, provided with compatible D{sub e} estimations with great accuracy, independent on either the type of mineral or the stimulation temperature. Low temperature ESR signals resulting from Al and Ti centers indicate very large D{sub e} values due to bleaching in-ability, associated with large uncertainty values. Additionally, dose saturation of different approaches was investigated. For the signal arising from Very Deep Traps in quartz saturation is extended almost by one order of magnitude. It is

  9. Evaluating biological transport of radionuclides at low-level waste burial sites

    International Nuclear Information System (INIS)

    Cadwell, L.L.; Kennedy, W.E.; McKenzie, D.H.

    1983-08-01

    The purpose of the work reported here is to develop and demonstrate methods for evaluating the long-term impact of biological processes at low-level waste (LLW) disposal sites. As part of this effort, we developed order-of-magnitude estimates of dose-to-man resulting from animal burrowing activity and plant translocation of radionuclides. Reference low-level waste sites in both arid and humid areas of the United States were examined. The results of our evaluation for generalized arid LLW burial site are presented here. Dose-to-man estimates resulting from biotic transport are compared with doses calculated from human intrusion exposure scenarios. Dose-to-man estimates, as a result of biotic transport, are of the same order of magnitude as those resulting from a more commonly evaluated human intrusion scenario. The reported lack of potential importance of biotic transport at LLW sites in earlier assessment studies is not confirmed by our findings. These results indicate that biotic transport has the long-term potential to mobilize radionuclides. Therefore, biotic transport should be carefully evaluated during burial site assessment

  10. Radiation hormesis: an outcome of exposure to low level ionizing radiation

    International Nuclear Information System (INIS)

    Kant, Krishan

    2012-01-01

    Ionizing radiation is a benign environmental agent at background levels. Human population is always exposed to ionizing radiation from natural sources. Important sources are cosmic rays which come from outer space and from the surface of the sun, terrestrial radionuclides which occur in the earths crust in various geological formations in soils, rocks, building materials, plants, water, food, air and in the human body itself. With the increasing use of radiation in health facilities, scientific research, industry and agriculture, the study of impact of low-level ionizing radiation on environment and possible health effects on future generations has been a cause of concern in recent years. As regards the effects, it is established fact that high doses of ionizing radiation are harmful to health, there exists, however, a substantial controversy regarding the effects of low doses of ionizing radiation (LLIR). In the present paper, brief review of the available literature, data and reports on stimulation by low-dose irradiation and recent data supporting radiation hormesis. A linear quadratic model has been given illustrating the validity of radiation hormesis, besides the comparison of the dose rates arising from natural and manmade sources to the Indian population. This overview summarizes various reports

  11. Politico-economic equivalence

    DEFF Research Database (Denmark)

    Gonzalez Eiras, Martin; Niepelt, Dirk

    2015-01-01

    Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime and a st......Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime...... their use in the context of several applications, relating to social security reform, tax-smoothing policies and measures to correct externalities....

  12. Periodic equivalence ratio modulation method and apparatus for controlling combustion instability

    Science.gov (United States)

    Richards, George A.; Janus, Michael C.; Griffith, Richard A.

    2000-01-01

    The periodic equivalence ratio modulation (PERM) method and apparatus significantly reduces and/or eliminates unstable conditions within a combustion chamber. The method involves modulating the equivalence ratio for the combustion device, such that the combustion device periodically operates outside of an identified unstable oscillation region. The equivalence ratio is modulated between preselected reference points, according to the shape of the oscillation region and operating parameters of the system. Preferably, the equivalence ratio is modulated from a first stable condition to a second stable condition, and, alternatively, the equivalence ratio is modulated from a stable condition to an unstable condition. The method is further applicable to multi-nozzle combustor designs, whereby individual nozzles are alternately modulated from stable to unstable conditions. Periodic equivalence ratio modulation (PERM) is accomplished by active control involving periodic, low frequency fuel modulation, whereby low frequency fuel pulses are injected into the main fuel delivery. Importantly, the fuel pulses are injected at a rate so as not to affect the desired time-average equivalence ratio for the combustion device.

  13. Human impacts on tides overwhelm the effect of sea level rise on extreme water levels in the Rhine-Meuse delta

    NARCIS (Netherlands)

    Vellinga, N. E.; Hoitink, A. J F; van der Vegt, M.; Zhang, W.; Hoekstra, P.

    2014-01-01

    With the aim to link tidal and subtidal water level changes to human interventions, 70. years of water level data for the Rhine-Meuse tidal river network is analysed using a variety of statistical methods. Using a novel parameterization of probability density functions, mean high and low water

  14. The impact of low level radioactive waste on humans and environment the next 100 thousands years

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, E.; Saetre, P.; Lindborg, T.; Norden, S.; Kautsky, U. [Svensk Kaernbraenslehantering AB - SKB (Sweden); Loefgren, A. [Ecoanalytica, Stockholm (Sweden)

    2014-07-01

    A safety assessment for the extension of the low level repository of operational waste (SFR) has been performed (SR-PSU). The repository (both existing and planned extension) is situated c 60 - 120 m below the surface in archaean granitoid rock. SR-PSU evaluates the risk to humans and the environment for the next 100 000 years. During this time period considerable changes are expected in the surface environment due climate change and its effects on shore line displacement, terrestrialisation of lakes and expansion of forest and agricultural land. In this paper specific approaches and results for the surface ecosystems (i.e. biosphere) are presented. The transport and accumulation of radionuclides in marine, lake, and terrestrial ecosystems are modelled and expose of future human populations during present conditions, greenhouse warming, and peri-glacial climate conditions are estimated taking into account different habits and diets of future humans. A new radionuclide transport model was developed to improve the representation of C-14 in the ecosystem modelling. In SR-PSU it is shown that the primary release from the repository via the geosphere to the biosphere is focused to a small area that will be a mire in about 1000 year. The radionuclides can thereafter be transported to downstream lakes and sea ecosystems. The aquatic systems can be utilised for fish and water whereas the mire can either be utilised directly by e.g. collecting, mushroom berries, hay, or hunting, or the mire can be transformed to a small agricultural area and utilised for crops. Important dose contributing radionuclides from SFR are Cl-36, Mo-93, C-14, Ni-59 and I-129 and in some of the scenarios the dose is close to the regulatory limit of 14 μSv/y (i.e. the risk 10{sup -6}). For Non-human biota (NHB) doses are estimated with a novel implementation of the ERICA tool in Ecolego. Generally the same radionuclides contributes to dose to NHB (reference organisms and site -specific organisms) as

  15. Update on low-level waste compacts and state agencies

    International Nuclear Information System (INIS)

    Tenan, M.; Rabbe, D.; Thompson, P.

    1995-01-01

    This article updates information on the following agencies involved in low-level radioactive wastes: Appalachian States Low-Level Radioactive Waste Commission; Central Interstate Low-Level radioactive Waste Commission; Central Midwest Interstate Low-Level radioactive Waste Compact; Massachusetts Low-Level radioactive Waste Management Board; Michigan Low-Level Radioactive Waste Authority; Midwest Interstate Low-Level Radioactive Waste Commission; New York State Low-Level Radioactive Waste Siting Commission; Northeast Interstate Low-Level Radioactive Waste Compact; Northwest Interstate Compact on Low-Level Radioactive Waste Management; Rocky Mountain Low-Level Radioactive Waste Board; Southeast Compact Commission for Low-Level Radioactive Waste Management;Southwest Low-Level Radioactive Waste Commission; Texas Low-Level Radioactive Waste Disposal Authority

  16. Effects of low-level laser therapy on wound healing

    Directory of Open Access Journals (Sweden)

    Fabiana do Socorro da Silva Dias Andrade

    Full Text Available OBJECTIVE: To gather and clarify the actual effects of low-level laser therapy on wound healing and its most effective ways of application in human and veterinary medicine.METHODS: We searched original articles published in journals between the years 2000 and 2011, in Spanish, English, French and Portuguese languages, belonging to the following databases: Lilacs, Medline, PubMed and Bireme; Tey should contain the methodological description of the experimental design and parameters used.RESULTS: doses ranging from 3 to 6 J/cm2 appear to be more effective and doses 10 above J/cm2 are associated with deleterious effects. The wavelengths ranging from 632.8 to 1000 nm remain as those that provide more satisfactory results in the wound healing process.CONCLUSION: Low-level laser can be safely applied to accelerate the resolution of cutaneous wounds, although this fact is closely related to the election of parameters such as dose, time of exposure and wavelength.

  17. Penelope simulation of electron beams 6 MeV from a linear accelerator for studies in different materials equivalent to human body

    International Nuclear Information System (INIS)

    Apaza V, D.; Cardena R, R.; Cayllahua Q, F.; Vega R, J.; Urquizo B, R.

    2015-10-01

    In systems of radiotherapy treatment for cancer, always looking to maximize the radiation dose on the target (tumor) and minimize to the organs at risk or healthy, so they resort to using electron beams that have properties and characteristics of higher dose deposition at fixed depths, directing and focusing the higher dose in the tumor, without harming healthy tissues to which seeks to radiate in the least possible. Simulating the interaction of electron beams with different equivalent tissues to the human body leads to a better dosimetric evaluation, improving the quality of treatment planning. The aim of this study is the comparison from the characterization of several equivalent tissues to the human body such as soft tissue, bone and lung. Based on the simulation of a calibration beam in water phantom with Penelope code and compared with the results of the calibration curves of beams in water vat by a linear accelerator Elekta Synergy of Hospital Nacional Carlos Alberto Seguin Escobedo EsSalud of Arequipa (Peru). From this to evaluate the behavior of electron beams in a homogeneous medium and then further evaluation in the human body homogeneities, for better evaluation and specific treatment planning. (Author)

  18. The paradox of human equivalent dose formula: A canonical case study of abrus precatorius aqueous leaf extract in monogastric animals

    Directory of Open Access Journals (Sweden)

    Saganuwan Alhaji Saganuwan

    2016-03-01

    Full Text Available There is abundant literature on the toxicity of A. precatorius seeds. However there is a need to define the toxicity limit of the Abrus precatorius leaf in monogastric animals. Human Equivalent Dose (HED which is equal to animal dose multiplied by animal km (metabolism constant divided by human km was used to project the LD50 of fifteen monogastric animals , where human km factor is body weight (kg divided by body surface area (m2. Human Equivalent No-observable Adverse Effect Doses were determined by multiplying the animal no-observable adverse effect dose by animal weight (Wa divided by human weight (Wh. The LD50 of the aqueous leaf extract of Abrus precatorius in mice was estimated to be between 2559.5 and 3123.3 mg/kg body weight. The LD50 extrapolated from mouse to rat (1349.3-1646.6 mg/kg, hamster (1855.3-2264.1 mg/kg, guinea pig (1279.5-1561.4 mg/kg, rabbit (618.4-754.7 mg/kg, monkey (593.7-724.5 mg/kg, cat (392.7-479.2 mg/kg, dog and baboon (371.1-452.8 mg/kg, child (297-362 mg/kg and adult human (197.8-241.5 mg/kg body weight respectively could be a reality. The therapeutic safe dose range for the animals was 1-12.5 mg/kg body weight for a period of 7 days, but at a dose (≤ 200 mg/kg body weight the leaf extract showed haematinic effect. However, at a higher dose (> 200 mg/kg, the extract showed haemolytic activity in rats, whereas at a dose (≥25.0 mg/kg, the leaf extract might be organotoxic in hamster, guinea pig, rabbit, monkey, cat, dog, baboon, child and adult human if administered orally for a period of 7 days.

  19. Scenarios of the TWRS low-level waste disposal program. Revision 1

    International Nuclear Information System (INIS)

    1995-01-01

    As a result of past Department of Energy (DOE) weapons material production operations, Hanford now stores nuclear waste from processing facilities in underground tanks on the 200 area plateau. An agreement between the DOE, the Environmental Protection Agency (EPA), and the Washington state Department of Ecology (the Tri-Party Agreement, or TPA) establishes an enforceable schedule and a technical framework for recovering, processing, solidifying, and disposing of the Hanford tank wastes. The present plan includes retrieving the tank waste, pre-treating the waste to separate into low level and high level streams, and converting both streams to a glass waste form. The low level glass will represent by far the largest volume and lowest quantity of radioactivity (i.e., large volume of waste chemicals) of waste requiring disposal. The low level glass waste will be retrievably stored in sub-surface disposal vaults for several decades. If the low level disposal system proves to be acceptable, the disposal site will be closed with the low level waste in place. If, however, at some time the disposal system is found to be unacceptable, then the waste can be retrieved and dealt with in some other manner. WHC is planning to emplace the waste so that it is retrievable for up to 50 years after completion of the tank waste processing. Acceptability of disposal of the TWRS low level waste at Hanford depends on technical, cultural, and political considerations. The Performance Assessment is a major part of determining whether the proposed disposal action is technically defensible. A Performance Assessment estimates the possible future impact to humans and the environment for thousands of years into the future. In accordance with the TPA technical strategy, WHC plans to design a near-surface facility suitable for disposal of the glass waste

  20. TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

    Energy Technology Data Exchange (ETDEWEB)

    Albanese, K; Morris, R; Spencer, J [Medical Physics Graduate Program, Duke University, Durham, NC (United States); Greenberg, J [Dept. of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States)

    2016-06-15

    Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs

  1. Low-level radioactive waste treatment technology. Low-level radioactive waste management handbook series

    International Nuclear Information System (INIS)

    1984-07-01

    Each generator of low-level radioactive waste must consider three sequential questions: (1) can the waste in its as-generated form be packaged and shipped to a disposal facility; (2) will the packaged waste be acceptable for disposal; and (3) if so, is it cost effective to dispose of the waste in its as-generated form. These questions are aimed at determining if the waste form, physical and chemical characteristics, and radionuclide content collectively are suitable for shipment and disposal in a cost-effective manner. If not, the waste management procedures will involve processing operations in addition to collection, segregation, packaging, shipment, and disposal. This handbook addresses methods of treating and conditioning low-level radioactive waste for shipment and disposal. A framework is provided for selection of cost-effective waste-processing options for generic categories of low-level radioactive waste. The handbook is intended as a decision-making guide that identifies types of information required to evaluate options, methods of evaluation, and limitations associated with selection of any of the processing options

  2. What is correct: equivalent dose or dose equivalent

    International Nuclear Information System (INIS)

    Franic, Z.

    1994-01-01

    In Croatian language some physical quantities in radiation protection dosimetry have not precise names. Consequently, in practice either terms in English or mathematical formulas are used. The situation is even worse since the Croatian language only a limited number of textbooks, reference books and other papers are available. This paper compares the concept of ''dose equivalent'' as outlined in International Commission on Radiological Protection (ICRP) recommendations No. 26 and newest, conceptually different concept of ''equivalent dose'' which is introduced in ICRP 60. It was found out that Croatian terminology is both not uniform and unprecise. For the term ''dose equivalent'' was, under influence of Russian and Serbian languages, often used as term ''equivalent dose'' even from the point of view of ICRP 26 recommendations, which was not justified. Unfortunately, even now, in Croatia the legal unit still ''dose equivalent'' defined as in ICRP 26, but the term used for it is ''equivalent dose''. Therefore, in Croatian legislation a modified set of quantities introduced in ICRP 60, should be incorporated as soon as possible

  3. Geological factors of disposal site selection for low-and intermediate-level solid radwastes in China

    International Nuclear Information System (INIS)

    Chen Zhangru

    1993-01-01

    For disposal of low- and intermediate-level solid radioactive wastes, shallow-ground disposal can provide adequate isolation of waste from human for a fairly long period of time. The objective of disposal site selection is to ensure that the natural properties of the site together with the engineered barrier site shall provide adequate isolation of radionuclides from the human beings and environment, so the whole disposal system can keep the radiological impact within an acceptable level. Since the early 1980's, complying with the national standards and the expert's conception as well as the related IAEA Criteria, geological selection of disposal sites for low-and intermediate-level solid radwastes has been carried out in East China, South China, Northwest China and Southwest China separately. Finally, 5 candidate sites were recommended to the CNNC

  4. Construction of a self-supporting tissue-equivalent dividing wall and operational characteristics of a coaxial double-cylindrical tissue-equivalent proportional counter

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.

    1994-01-01

    An additional feature incorporated in a coaxial double-cylindrical tissue-equivalent proportional counter, is the presence of a common tissue-equivalent dividing wall between the inner and outer counters of thickness equivalent to the corresponding maximum range of protons at the energy of interest. By appropriate use of an anti-coincidence arrangement with the outer counter, the inner counter could be used to discriminate microdosimetric spectra of neutrons at the desired low energy range from those of the faster neutrons. The construction of an A-150 self-supporting tissue-equivalent dividing wall and an anti-coincidence unit are described. Some operational characteristic tests have been performed to determine the operation of the new microdosimeter. (author)

  5. The assessment of risks from exposure to low-levels of ionizing radiation

    International Nuclear Information System (INIS)

    Gilbert, E.S.

    1992-06-01

    This report is concerned with risk assessments for human populations receiving low level radiation doses; workers routinely exposed to radiation, Japanese victims of nuclear bombs, and the general public are all considered. Topics covered include risk estimates for cancer, mortality rates, risk estimates for nuclear site workers, and dosimetry

  6. Risk evaluation - conventional and low level effects of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.; Varma, M.N.

    1984-04-01

    Any discussion of the risk of exposure to potentially-hazardous agents in the environment inevitably involves the question of whether the dose effect curve is of the threshold or linear, non-threshold type. A principal objective of this presentation is to show that the function is actually two separate relationships, each representing distinctly different functions with differing variables on the axes, and each characteristic of quite different functions with differing variables on the axes, and each characteristic of quite different disciplines (i.e., the threshold function, of Pharmacology, Toxicology and Medicine [PTM]; the linear, non-threshold function, of Public Health including safety and accident statistics [PHS]). It is shown that low-level exposure (LLE) to radiation falls clearly in the PHS category. A function for cell dose vs. the fraction of single cell quantal responses is characterized, which reflects the absolute and relative sensitivities of cells. Acceptance of this function would obviate any requirement for the use in Radiation Protection of the concepts of a standard radiation, Q, dose equivalent and rem. 9 references, 4 figures

  7. Radiological equivalent of chemical pollutants

    International Nuclear Information System (INIS)

    Medina, V.O.

    1982-01-01

    The development of the peaceful uses of nuclear energy has caused continued effort toward public safety through radiation health protection measures and nuclear management practices. However, concern has not been focused on the development specifically in the operation of chemical pestrochemical industries as well as other industrial processes brought about by technological advancements. This article presents the comparison of the risk of radiation and chemicals. The methods used for comparing the risks of late effects of radiation and chemicals are considered at three levels. (a) as a frame of reference to give an impression of resolving power of biological tests; (b) as methods to quantify risks; (c) as instruments for an epidemiological survey of human populations. There are marked dissimilarities between chemicals and radiation and efforts to interpret chemical activity may not be achieved. Applicability of the concept of rad equivalence has many restrictions and as pointed out this approach is not an established one. (RTD)

  8. In vitro analysis of low-level laser irradiation on human osteoblast-like cells proliferation

    Science.gov (United States)

    Bloise, Nora; Saino, Enrica; Bragheri, Francesca; Minzioni, Paolo; Cristiani, Ilaria; Imbriani, Marcello; Visai, Livia

    2011-07-01

    The objective of this study was to examine the in vitro effect of a single or a multiple doses of low-level laser irradiation (LLLI) on proliferation of the human osteosarcoma cell line, SAOS-2. SAOS-2 cells were divided in five groups and exposed to LLLI (659 nm diode laser; 11 mW power output): group I as a control (dark), group II exposed to a single laser dose of 1 J/cm2, group III irradiated with a single dose of 3 J/cm2, and group IV and V exposed for three consecutive days to 1 or 3 J/cm², respectively. Cellular proliferation was assessed daily up to 7 days of culturing. The obtained results showed an increase in proliferative capacity of SAOS-2 cells during the first 96 h of culturing time in once-irradiated cells, as compared to control cells. Furthermore, a significantly higher proliferation in the group IV and V was detected if compared to a single dose or to control group after 96 h and 7 days. In conclusion, the effect of the single dose on cell proliferation was transitory and repeated irradiations were necessary to observe a strong enhancement of SAOS-2 growth. As a future perspective, we would like to determine the potential of LLLI as a new approach for promoting bone regeneration onto biomaterials.

  9. Sphere of equivalence--a novel target volume concept for intraoperative radiotherapy using low-energy X rays.

    Science.gov (United States)

    Herskind, Carsten; Griebel, Jürgen; Kraus-Tiefenbacher, Uta; Wenz, Frederik

    2008-12-01

    Accelerated partial breast radiotherapy with low-energy photons from a miniature X-ray machine is undergoing a randomized clinical trial (Targeted Intra-operative Radiation Therapy [TARGIT]) in a selected subgroup of patients treated with breast-conserving surgery. The steep radial dose gradient implies reduced tumor cell control with increasing depth in the tumor bed. The purpose was to compare the expected risk of local recurrence in this nonuniform radiation field with that after conventional external beam radiotherapy. The relative biologic effectiveness of low-energy photons was modeled using the linear-quadratic formalism including repair of sublethal lesions during protracted irradiation. Doses of 50-kV X-rays (Intrabeam) were converted to equivalent fractionated doses, EQD2, as function of depth in the tumor bed. The probability of local control was estimated using a logistic dose-response relationship fitted to clinical data from fractionated radiotherapy. The model calculations show that, for a cohort of patients, the increase in local control in the high-dose region near the applicator partly compensates the reduction of local control at greater distances. Thus a "sphere of equivalence" exists within which the risk of recurrence is equal to that after external fractionated radiotherapy. The spatial distribution of recurrences inside this sphere will be different from that after conventional radiotherapy. A novel target volume concept is presented here. The incidence of recurrences arising in the tumor bed around the excised tumor will test the validity of this concept and the efficacy of the treatment. Recurrences elsewhere will have implications for the rationale of TARGIT.

  10. Equivalent noise level response to number of vehicles: a comparison between a high traffic flow and low traffic flow highway in Klang Valley, Malaysia

    OpenAIRE

    Halim, Herni; Abdullah, Ramdzani

    2014-01-01

    HIGHLIGHTS Highway traffic noise is a serious problem in Malaysia Heavy traffic flow highway recorded higher noise level compared to low traffic flow Noise level stabilized at certain number of vehicles on the road i.e above 500 vehicles. Although much research on road traffic noise has found that noise level increase are influenced by driver behavior and source-receiver distance, little attention has been paid to the relationship between noise level and total number of vehicles...

  11. Low-level radioactive waste

    International Nuclear Information System (INIS)

    McLaren, L.H.

    1983-03-01

    This bibliography contains information on low-level radioactive waste included in the Department of Energy's Energy Data Base for January through December 1982. The abstracts are grouped by subject category as shown in the table of contents. Entries in the subject index also facilitate access by subject, e.g., Low-Level Radioactive Wastes/Transport. Within each category the arrangement is by report number for reports, followed by nonreports in reverse chronological order. These citations are to research reports, journal articles, books, patents, theses, and conference papers from worldwide sources. Five indexes, each proceded by a brief description, are provided: Corporate Author, Personal Author, Subject, Contract Number, and Report Number. 492 references

  12. Effect of cholesterol and triglycerides levels on the rheological behavior of human blood

    Science.gov (United States)

    Moreno, Leonardo; Calderas, Fausto; Sanchez-Olivares, Guadalupe; Medina-Torres, Luis; Sanchez-Solis, Antonio; Manero, Octavio

    2015-02-01

    Important public health problems worldwide such as obesity, diabetes, hyperlipidemia and coronary diseases are quite common. These problems arise from numerous factors, such as hyper-caloric diets, sedentary habits and other epigenetic factors. With respect to Mexico, the population reference values of total cholesterol in plasma are around 200 mg/dL. However, a large proportion has higher levels than this reference value. In this work, we analyze the rheological properties of human blood obtained from 20 donors, as a function of cholesterol and triglyceride levels, upon a protocol previously approved by the health authorities. Samples with high and low cholesterol and triglyceride levels were selected and analyzed by simple-continuous and linear-oscillatory shear flow. Rheometric properties were measured and related to the structure and composition of human blood. In addition, rheometric data were modeled by using several constitutive equations: Bautista-Manero-Puig (BMP) and the multimodal Maxwell equations to predict the flow behavior of human blood. Finally, a comparison was made among various models, namely, the BMP, Carreau and Quemada equations for simple shear rate flow. An important relationship was found between cholesterol, triglycerides and the structure of human blood. Results show that blood with high cholesterol levels (400 mg/dL) has flow properties fully different (higher viscosity and a more pseudo-plastic behavior) than blood with lower levels of cholesterol (tendency to Newtonian behavior or viscosity plateau at low shear rates).

  13. Mathematical simulation of biologically equivalent doses for LDR-HDR

    International Nuclear Information System (INIS)

    Slosarek, K.; Zajusz, A.

    1996-01-01

    Based on the LQ model examples of biologically equivalent doses LDR, HDR and external beams were calculated. The biologically equivalent doses for LDR were calculated by appending to the LQ model the corrector for the time of repair of radiation sublethal damages. For radiation continuously delivered at a low dose rate the influence of sublethal damage repair time changes on biologically equivalent doses were analysed. For fractionated treatment with high dose rate the biologically equivalent doses were calculated by adding to the LQ model the formula of accelerated repopulation. For total biologically equivalent dose calculation for combine LDR-HDR-Tele irradiation examples are presented with the use of different parameters of the time of repair of sublethal damages and accelerated repopulation. The calculations performed show, that the same biologically equivalent doses can be obtained for different parameters of cell kinetics changes during radiation treatment. It also shows, that during biologically equivalent dose calculations for different radiotherapy schedules, ignorance of cell kinetics parameters can lead to relevant errors

  14. Equivalent electrical network model approach applied to a double acting low temperature differential Stirling engine

    International Nuclear Information System (INIS)

    Formosa, Fabien; Badel, Adrien; Lottin, Jacques

    2014-01-01

    Highlights: • An equivalent electrical network modeling of Stirling engine is proposed. • This model is applied to a membrane low temperate double acting Stirling engine. • The operating conditions (self-startup and steady state behavior) are defined. • An experimental engine is presented and tested. • The model is validated against experimental results. - Abstract: This work presents a network model to simulate the periodic behavior of a double acting free piston type Stirling engine. Each component of the engine is considered independently and its equivalent electrical circuit derived. When assembled in a global electrical network, a global model of the engine is established. Its steady behavior can be obtained by the analysis of the transfer function for one phase from the piston to the expansion chamber. It is then possible to simulate the dynamic (steady state stroke and operation frequency) as well as the thermodynamic performances (output power and efficiency) for given mean pressure, heat source and heat sink temperatures. The motion amplitude especially can be determined by the spring-mass properties of the moving parts and the main nonlinear effects which are taken into account in the model. The thermodynamic features of the model have then been validated using the classical isothermal Schmidt analysis for a given stroke. A three-phase low temperature differential double acting free membrane architecture has been built and tested. The experimental results are compared with the model and a satisfactory agreement is obtained. The stroke and operating frequency are predicted with less than 2% error whereas the output power discrepancy is of about 30%. Finally, some optimization routes are suggested to improve the design and maximize the performances aiming at waste heat recovery applications

  15. Mixed and Low-Level Treatment Facility Project

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    This appendix contains the mixed and low-level waste engineering design files (EDFS) documenting each low-level and mixed waste stream investigated during preengineering studies for Mixed and Low-Level Waste Treatment Facility Project. The EDFs provide background information on mixed and low-level waste generated at the Idaho National Engineering Laboratory. They identify, characterize, and provide treatment strategies for the waste streams. Mixed waste is waste containing both radioactive and hazardous components as defined by the Atomic Energy Act and the Resource Conservation and Recovery Act, respectively. Low-level waste is waste that contains radioactivity and is not classified as high-level waste, transuranic waste, spent nuclear fuel, or 11e(2) byproduct material as defined by DOE 5820.2A. Test specimens of fissionable material irradiated for research and development only, and not for the production of power or plutonium, may be classified as low-level waste, provided the concentration of transuranic is less than 100 nCi/g. This appendix is a tool that clarifies presentation format for the EDFS. The EDFs contain waste stream characterization data and potential treatment strategies that will facilitate system tradeoff studies and conceptual design development. A total of 43 mixed waste and 55 low-level waste EDFs are provided.

  16. Mixed and Low-Level Treatment Facility Project

    International Nuclear Information System (INIS)

    1992-04-01

    This appendix contains the mixed and low-level waste engineering design files (EDFS) documenting each low-level and mixed waste stream investigated during preengineering studies for Mixed and Low-Level Waste Treatment Facility Project. The EDFs provide background information on mixed and low-level waste generated at the Idaho National Engineering Laboratory. They identify, characterize, and provide treatment strategies for the waste streams. Mixed waste is waste containing both radioactive and hazardous components as defined by the Atomic Energy Act and the Resource Conservation and Recovery Act, respectively. Low-level waste is waste that contains radioactivity and is not classified as high-level waste, transuranic waste, spent nuclear fuel, or 11e(2) byproduct material as defined by DOE 5820.2A. Test specimens of fissionable material irradiated for research and development only, and not for the production of power or plutonium, may be classified as low-level waste, provided the concentration of transuranic is less than 100 nCi/g. This appendix is a tool that clarifies presentation format for the EDFS. The EDFs contain waste stream characterization data and potential treatment strategies that will facilitate system tradeoff studies and conceptual design development. A total of 43 mixed waste and 55 low-level waste EDFs are provided

  17. Reasons for Low Levels of Interactivity

    DEFF Research Database (Denmark)

    Etter, Michael

    2013-01-01

    The interactivity levels of online CSR communication are typically low. This study explores the reasons for the low levels of interactivity in the popular social media tool Twitter. An analysis of 41,864 Twitter messages (tweets) from the thirty most central corporate accounts in a CSR Twitter...... network is conducted. Comparisons (t-test) between CSR tweets and general tweets and between specialized CSR Twitter accounts and general accounts reveal that the low levels of interactivity are due to a reactive interaction approach and a lack of specialization....

  18. Effect of Short-term 900 MHz low level electromagnetic radiation exposure on blood serotonin and glutamate levels.

    Science.gov (United States)

    Eris, A H; Kiziltan, H S; Meral, I; Genc, H; Trabzon, M; Seyithanoglu, H; Yagci, B; Uysal, O

    2015-01-01

    Long term exposure to low level electromagnetic radiation (LLER) by using cellular phones causes serious health problems. Ten male Wistar Albino rats were anesthetized 30 min before the LLER exposure, 0.5 ml blood was taken from the tail vein of rats in order to determine control values. Rats were grouped by three and placed on a plexi-glass flat. A fixed equivalent frequency emitter device was used. A sign to be an electromagnetic field 15.14 V/m (608 mW/m(2)) in strength in the head region with 100 kHz FM modulation at 900 MHz was applied to the animals. After calculating the ideal position for the device, electromagnetic LLER energy was applied for 45 minutes from a distance to be equal with energy transmitted by a mobile phone from a 0.5-1 cm distance to their head regions. After 1.5 hours and before the rats awoke, 0.5 ml of blood was taken from the tail veins in order to determine the treatment values. Plasma 5-HT and glutamate levels were measured by enzyme immunoassay (EIA) using commercial kits. It was found that a single 45 min of LLER exposure increased the blood 5-HT level significantly, but did not change the glutamate level of rats. It was concluded that even a single 45 min of LLER exposure may produce an increase in 5-HT level without changing the blood glutamate level. Increased 5-HT level may lead to a retarded learning and a deficit in spatial memory (Tab. 2, Fig. 2, Ref. 24).

  19. National Low-Level Waste Management Program Radionuclide Report Series. Volume 10, Nickel-63

    Energy Technology Data Exchange (ETDEWEB)

    Carboneau, M.L.; Adams, J.P.

    1995-02-01

    This report outlines the basic radiological, chemical, and physical characteristics of nickel-63 ({sup 63}Ni) and examines how these characteristics affect the behavior of {sup 63}Ni in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of {sup 63}Ni production, waste types, and waste forms that contain {sup 63}Ni. The primary source of {sup 63}Ni in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable {sup 62}Ni that is present in the structural components of nuclear reactor vessels. {sup 63}Ni enters the environment from the dismantling activities associated with nuclear reactor decommissioning. However, small amounts of {sup 63}Ni have been detected in the environment following the testing of thermonuclear weapons in the South Pacific. Concentrations as high as 2.7 Bq{sup a} per gram of sample (or equivalently 0.0022 parts per billion) were observed on Bikini Atoll (May 1954). {sup 63}Ni was not created as a fission product species (e.g., from {sup 235}U or {sup 239}Pu fissions), but instead was produced as a result of neutron capture in {sup 63}Ni, a common nickel isotope present in the stainless steel components of nuclear weapons (e.g., stainless-304 contains {approximately}9% total Ni or {approximately}0.3% {sup 63}Ni).

  20. The effective dose equivalent from external and internal radiation

    International Nuclear Information System (INIS)

    Mattsson, Soeren

    1989-01-01

    The various sources of low-level ionizing radiation are discussed and compared in terms of mean effective dose equivalent to man. For the most nonoccupationally exposed individuals, natural sources given the dominating contribution to the effective dose equivalent. The size of this contribution is strongly dependent on human activities. Natural sources contribution on average 2.4 mSV per year, of which half is due to irradiation of lungs and airways from short lived radon daughters present in indoor air. In Sweden this radon daughter contribution is considerably higher and contributes a mean of 3 mSv per year, thus giving a total contribution from natural radiation of about 4 mSV per year. In extreme cases, radon daughter contributions of several hundreds of mSv per year may be reached. Medical exposure, mainly diagnostic X-rays, contributes 0.4-1 mSv per year both in Sweden and as a world average. The testing of nuclear weapons in the atmosphere has given 1-2 mSv to each person in the world as a mean. The contribution from the routine operation of nuclear reactors is insignificant. The reactor accident in Chernobyl resulted in widely varying exposures of the European population. The average for Sweden is estimated to be 0.1 mSv during the first year and about 1 mSv during a 50-year period. For groups of Swedes who eat a considerable amount of game this contribution will be 10 times higher, and for the Lapps who breed reindeer in the most contaminated areas, typical values of 20-70 mSv and extreme values of about 1 Sv may be reached in 50 years. This means that the Chernobyl reactor accident for several years will be their dominating source of irradiation

  1. Incidence of high-level evernimicin resistance in Enterococcus faecium among food animals and humans

    DEFF Research Database (Denmark)

    Aarestrup, Frank Møller; McNicholas, P. M.

    2002-01-01

    Six high-level evernimicin-resistant Enterococcus faecium isolates were identified among 304 avilarnycin-resistant E. faecium isolates from animals and 404 stool samples from humans with diarrhea. All four animal isolates, and one of the human isolates, were able to transfer resistance...... to a susceptible E. faecium strain. The resulting transconjugants all tested positive for the presence of emtA, a gene encoding a methyltransferase previously linked with high-level evernimicin resistance. The four transconjugants derived from animal isolates all carried the same plasmid, while a differently sized...... plasmid was found in the isolate from humans. This study demonstrated a low incidence of high-level evernimicin resistance mediated by the emtA gene in different E. faecium isolates of animal and human origin....

  2. Low-frequency sound affects active micromechanics in the human inner ear

    Science.gov (United States)

    Kugler, Kathrin; Wiegrebe, Lutz; Grothe, Benedikt; Kössl, Manfred; Gürkov, Robert; Krause, Eike; Drexl, Markus

    2014-01-01

    Noise-induced hearing loss is one of the most common auditory pathologies, resulting from overstimulation of the human cochlea, an exquisitely sensitive micromechanical device. At very low frequencies (less than 250 Hz), however, the sensitivity of human hearing, and therefore the perceived loudness is poor. The perceived loudness is mediated by the inner hair cells of the cochlea which are driven very inadequately at low frequencies. To assess the impact of low-frequency (LF) sound, we exploited a by-product of the active amplification of sound outer hair cells (OHCs) perform, so-called spontaneous otoacoustic emissions. These are faint sounds produced by the inner ear that can be used to detect changes of cochlear physiology. We show that a short exposure to perceptually unobtrusive, LF sounds significantly affects OHCs: a 90 s, 80 dB(A) LF sound induced slow, concordant and positively correlated frequency and level oscillations of spontaneous otoacoustic emissions that lasted for about 2 min after LF sound offset. LF sounds, contrary to their unobtrusive perception, strongly stimulate the human cochlea and affect amplification processes in the most sensitive and important frequency range of human hearing. PMID:26064536

  3. Electrocortical correlates of human level-ground, slope, and stair walking.

    Science.gov (United States)

    Luu, Trieu Phat; Brantley, Justin A; Nakagome, Sho; Zhu, Fangshi; Contreras-Vidal, Jose L

    2017-01-01

    This study investigated electrocortical dynamics of human walking across different unconstrained walking conditions (i.e., level ground (LW), ramp ascent (RA), and stair ascent (SA)). Non-invasive active-electrode scalp electroencephalography (EEG) signals were recorded and a systematic EEG processing method was implemented to reduce artifacts. Source localization combined with independent component analysis and k-means clustering revealed the involvement of four clusters in the brain during the walking tasks: Left and Right Occipital Lobe (LOL, ROL), Posterior Parietal Cortex (PPC), and Central Sensorimotor Cortex (SMC). Results showed that the changes of spectral power in the PPC and SMC clusters were associated with the level of motor task demands. Specifically, we observed α and β suppression at the beginning of the gait cycle in both SA and RA walking (relative to LW) in the SMC. Additionally, we observed significant β rebound (synchronization) at the initial swing phase of the gait cycle, which may be indicative of active cortical signaling involved in maintaining the current locomotor state. An increase of low γ band power in this cluster was also found in SA walking. In the PPC, the low γ band power increased with the level of task demands (from LW to RA and SA). Additionally, our results provide evidence that electrocortical amplitude modulations (relative to average gait cycle) are correlated with the level of difficulty in locomotion tasks. Specifically, the modulations in the PPC shifted to higher frequency bands when the subjects walked in RA and SA conditions. Moreover, low γ modulations in the central sensorimotor area were observed in the LW walking and shifted to lower frequency bands in RA and SA walking. These findings extend our understanding of cortical dynamics of human walking at different level of locomotion task demands and reinforces the growing body of literature supporting a shared-control paradigm between spinal and cortical

  4. Development of a low-level radioactive waste shipper model. National Low-Level Radioactive Waste Management Program

    International Nuclear Information System (INIS)

    1983-03-01

    During 1982, Inter/Face Associates, Inc., conducted a low-level radioactive waste management survey of Nuclear Regulatory Commission (NRC) licensees in Massachusetts for the US Department of Energy's National Low-Level Waste Management Program. In the process of conducting the survey, a model was developed, based on existing NRC license classification systems, that would identify licensees who ship low-level waste for disposal. This report presents the model and documents the procedures used in developing and testing it. After the model was tested, several modifications were developed with the goal of determining the model's ability to identify waste shippers under different parameters. The report includes a discussion of the modifications

  5. Re-establishment of the air kerma and ambient dose equivalent standards for the BIPM protection-level 60Co beam

    International Nuclear Information System (INIS)

    Kessler, C.; Roger, P.

    2005-07-01

    The air kerma and ambient dose equivalent standards for the protection-level 60 Co beam have been re-established following the repositioning of the irradiator and modifications to the beam. Details concerning the standards and the new uncertainty budgets are described in this report with their implications for dosimetry comparisons and calibrations. (authors)

  6. Low-level pixelated representations suffice for aesthetically pleasing contrast adjustment in photographs

    Directory of Open Access Journals (Sweden)

    Ghose Tandra

    2017-01-01

    Full Text Available Today’s web-based automatic image enhancement algorithms decide to apply an enhancement operation by searching for “similar” images in an online database of images and then applying the same level of enhancement as the image in the database. Two key bottlenecks in these systems are the storage cost for images and the cost of the search. Based on the principles of computational aesthetics, we consider storing task-relevant aesthetic summaries, a set of features which are sufficient to predict the level at which an image enhancement operation should be performed, instead of the entire image. The empirical question, then, is to ensure that the reduced representation indeed maintains enough information so that the resulting operation is perceived to be aesthetically pleasing to humans. We focus on the contrast adjustment operation, an important image enhancement primitive. We empirically study the efficacy of storing a pixelated summary of the 16 most representative colors of an image and performing contrast adjustments on this representation. We tested two variants of the pixelated image: a “mid-level pixelized version” that retained spatial relationships and allowed for region segmentation and grouping as in the original image and a “low-level pixelized-random version” which only retained the colors by randomly shuffling the 50 x 50 pixels. In an empirical study on 25 human subjects, we demonstrate that the preferred contrast for the low-level pixelized-random image is comparable to the original image even though it retains very few bits and no semantic information, thereby making it ideal for image matching and retrieval for automated contrast editing. In addition, we use an eye tracking study to show that users focus only on a small central portion of the low-level image, thus improving the performance of image search over commonly used computer vision algorithms to determine interesting key points.

  7. Supersymmetric quantum mechanics, phase equivalence, and low energy scattering anomalies

    International Nuclear Information System (INIS)

    Amado, R.D.; Cannata, F.; Dedonder, J.P.

    1991-01-01

    Supersymmetric quantum mechanics links two Hamiltonians with the same scattering (phase equivalence) but different number of bound states. We examine the Green's functions for these Hamiltonians as a prelude to embedding the two-body dynamics in a many-body system. We study the effect of the elimination of a two-body bound state near zero energy for the Efimov effect and Beg's theorem

  8. Low-Level Waste (LLW) forum meeting report

    International Nuclear Information System (INIS)

    1995-01-01

    The Low-Level Radioactive Waste Forum (LLW Forum) is an association of state and compact representatives, appointed by governors and compact commissions, established to facilitate state and compact implementation of the Low-Level Radioactive Waste Policy Act of 1980 and the Low-Level Radioactive Waste Policy Amendments Act of 1985 and to promote the objectives of low-level radioactive waste regional compacts. The LLW Forum provides an opportunity for state and compact officials to share information with one another and to exchange views with officials of federal agencies and other interested parties

  9. Low-Level Waste (LLW) forum meeting report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The Low-Level Radioactive Waste Forum (LLW Forum) is an association of state and compact representatives, appointed by governors and compact commissions, established to facilitate state and compact implementation of the Low-Level Radioactive Waste Policy Act of 1980 and the Low-Level Radioactive Waste Policy Amendments Act of 1985 and to promote the objectives of low-level radioactive waste regional compacts. The LLW Forum provides an opportunity for state and compact officials to share information with one another and to exchange views with officials of federal agencies and other interested parties.

  10. Clustered DNA damages induced in human hematopoietic cells by low doses of ionizing radiation

    Science.gov (United States)

    Sutherland, Betsy M.; Bennett, Paula V.; Cintron-Torres, Nela; Hada, Megumi; Trunk, John; Monteleone, Denise; Sutherland, John C.; Laval, Jacques; Stanislaus, Marisha; Gewirtz, Alan

    2002-01-01

    Ionizing radiation induces clusters of DNA damages--oxidized bases, abasic sites and strand breaks--on opposing strands within a few helical turns. Such damages have been postulated to be difficult to repair, as are double strand breaks (one type of cluster). We have shown that low doses of low and high linear energy transfer (LET) radiation induce such damage clusters in human cells. In human cells, DSB are about 30% of the total of complex damages, and the levels of DSBs and oxidized pyrimidine clusters are similar. The dose responses for cluster induction in cells can be described by a linear relationship, implying that even low doses of ionizing radiation can produce clustered damages. Studies are in progress to determine whether clusters can be produced by mechanisms other than ionizing radiation, as well as the levels of various cluster types formed by low and high LET radiation.

  11. Basement membrane reconstruction in human skin equivalents is regulated by fibroblasts and/or exogenously activated keratinocytes.

    Science.gov (United States)

    El Ghalbzouri, Abdoelwaheb; Jonkman, Marcel F; Dijkman, Remco; Ponec, Maria

    2005-01-01

    This study was undertaken to examine the role fibroblasts play in the formation of the basement membrane (BM) in human skin equivalents. For this purpose, keratinocytes were seeded on top of fibroblast-free or fibroblast-populated collagen matrix or de-epidermized dermis and cultured in the absence of serum and exogenous growth factors. The expression of various BM components was analyzed on the protein and mRNA level. Irrespective of the presence or absence of fibroblasts, keratin 14, hemidesmosomal proteins plectin, BP230 and BP180, and integrins alpha1beta1, alpha2beta1, alpha3beta1, and alpha6beta4 were expressed but laminin 1 was absent. Only in the presence of fibroblasts or of various growth factors, laminin 5 and laminin 10/11, nidogen, uncein, type IV and type VII collagen were decorating the dermal/epidermal junction. These findings indicate that the attachment of basal keratinocytes to the dermal matrix is most likely mediated by integrins alpha1beta1 and alpha2beta1, and not by laminins that bind to integrin alpha6beta4 and that the epithelial-mesenchymal cross-talk plays an important role in synthesis and deposition of various BM components.

  12. Noise equivalent count measurements in a neuro-PET scanner with retractable septa

    International Nuclear Information System (INIS)

    Bailey, D.L.; Jones, T.; Spinks, T.J.; Gilardi, M.C.; Townsend, D.W.

    1990-01-01

    This paper reports on the removal of interplane septa in a PET scanner that enables acquisition of all possible lines of response (3D mode) in an effort to maximize the available number of detected events. One problem with this method at high countrates, however, is a markedly increased deadtime and randoms rate, which has a deleterious effect on data quality. The noise-equivalent countrate (NEC) performance of a neuro-PET scanner has been determined with and without interplane septa on uniform cylindrical phantoms of differing radii and in human studies to assess the optimum countrate conditions that realize the maximum gain. In the brain, the effective gain in NEC performance for 3D ranges from >5 at low countrates to ∼3.3 at 200 kcps (equivalent to 37 kcps in 2D). The gains of the 3D method assessed by this analysis are significant, and are shown to be highly dependent on countrate and object dimensions

  13. A systematic review of Bisphenol A "low dose" studies in the context of human exposure: a case for establishing standards for reporting "low-dose" effects of chemicals.

    Science.gov (United States)

    Teeguarden, Justin G; Hanson-Drury, Sesha

    2013-12-01

    Human exposure to the chemical Bisphenol A is almost ubiquitous in surveyed industrialized societies. Structural features similar to estrogen confer the ability of Bisphenol A (BPA) to bind estrogen receptors, giving BPA membership in the group of environmental pollutants called endocrine disruptors. References by scientists, the media, political entities, and non-governmental organizations to many toxicity studies as "low dose" has led to the belief that exposure levels in these studies are similar to humans, implying that BPA is toxic to humans at current exposures. Through systematic, objective comparison of our current, and a previous compilation of the "low-dose" literature to multiple estimates of human external and internal exposure levels, we found that the "low-dose" moniker describes exposures covering 8-12 orders of magnitude, the majority (91-99% of exposures) being greater than the upper bound of human exposure in the general infant, child and adult U.S. Population. "low dose" is therefore a descriptor without specific meaning regarding human exposure. Where human exposure data are available, for BPA and other environmental chemicals, reference to toxicity study exposures by direct comparison to human exposure would be more informative, more objective, and less susceptible to misunderstanding. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Processing of low-level wastes

    International Nuclear Information System (INIS)

    Vance, J.N.

    1986-01-01

    Although low-level wastes have been generated and have required processing for more than two decades now, it is noteworthy that processing methods are continuing to change. The changes are not only attributable to improvements in technology, but are also the result of changing regulations and economics and uncertainties regarding the future availabilities of burial space for disposal. Indeed, because of the changes which have and are taking place in the processing of low-level waste, an overview of the current situation is in order. This presentation is a brief overview of the processing methods generally employed to treat the low-level wastes generated from both fuel cycle and non-fuel cycle sources. The presentation is far too brief to deal with the processing technologies in a comprehensive fashion, but does provide a snapshot of what the current or typical processing methods are and what changes are occurring and why

  15. Energetic consumption levels and human development indexes

    International Nuclear Information System (INIS)

    Boa Nova, Antonio Carlos

    1999-01-01

    The article overviews the energetic consumption levels and human development indexes. The human development indexes are described based on the United Nations Development Programme. A comparison between the energetic consumption levels and human development indexes is also presented

  16. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  17. Health effects of low level radiation

    International Nuclear Information System (INIS)

    Chevillard, S.; Ugolin, N.; Lebeau, J.; Ory, K.

    2006-01-01

    Nuclear energy production is necessarily associated with the handling and storage of radioactive elements, which are liable to have deleterious effects on human health, and on environment. These deleterious effects are varied, but they greatly depend on the dose, which has been received, and the exposure type. Therefore, only intense and massive exposures are liable to be clinically detected. They can entail immediate consequences, even lead to the person's death. Thanks to safety measures, which have been implemented to an international scale, this occurs very rarely. Excluding extensive accidental cases, medical irradiation for therapeutic use and conflicts, workers and population in general are exposed to low doses and low dose-rates. Low dose exposures, resulting from either a contamination or an external irradiation are more frequent. In fact, we could say that the whole humanity is concerned by natural exposure, which varies depending on regions, as well as by medical exposure, which varies depending on the medicalisation status of the country. (author)

  18. Low-level waste workshops. Final report

    International Nuclear Information System (INIS)

    1983-01-01

    The Low-Level Radioactive Waste Policy Act of 1980 specifies that each state is responsible for the disposal of the low-level waste which is generated within its boundaries. The Act states that such wastes can be most safely and efficiently managed on a regional basis through compacts. It also defines low-level waste as waste which is not classified as high-level radioactive waste, transuranic waste, spent nuclear fuel, or by-product material as defined in the Atomic Energy Act of 1954. The Policy Act also stipulates that regional agreements or compacts shall not be applicable to the transportation, management, or disposal of low-level radioactive waste from atomic energy defense activities or federal research and development activities. It also specifies that agreements or compacts shall take affect on January 1, 1986, upon Congressional approval. In February 1983, the US Department of Energy awarded a grant to the Council of State Governments' Midwestern Office. The grant was to be used to fund workshops for legislation on low-level radioactive waste issues. The purpose of the workshops was to provide discussion specifically on the Midwest Interstate Compact on Low-Level Radioactive Waste. Legislators from the states which were eligible to join the compact were invited: Delaware, Illinois, Indiana, Iowa, Kentucky, Maryland, Michigan, Minnesota, Missouri, North Dakota, Ohio, South Dakota and Wisconsin. Virginia, Kansas and Nebraska were also eligible but had joined other compacts. Consequently, they weren't invited to the workshops. The Governor's office of West Virginia expressed interest in the compact, and its legislators were invited to attend a workshop. Two workshops were held in March. This report is a summary of the proceedings which details the concerns of the compact and expresses the reasoning behind supporting or not supporting the compact

  19. Mechanisms of anaphylaxis in human low-affinity IgG receptor locus knock-in mice.

    Science.gov (United States)

    Gillis, Caitlin M; Jönsson, Friederike; Mancardi, David A; Tu, Naxin; Beutier, Héloïse; Van Rooijen, Nico; Macdonald, Lynn E; Murphy, Andrew J; Bruhns, Pierre

    2017-04-01

    Anaphylaxis can proceed through distinct IgE- or IgG-dependent pathways, which have been investigated in various mouse models. We developed a novel mouse strain in which the human low-affinity IgG receptor locus, comprising both activating (hFcγRIIA, hFcγRIIIA, and hFcγRIIIB) and inhibitory (hFcγRIIB) hFcγR genes, has been inserted into the equivalent murine locus, corresponding to a locus swap. We sought to determine the capabilities of hFcγRs to induce systemic anaphylaxis and identify the cell types and mediators involved. hFcγR expression on mouse and human cells was compared to validate the model. Passive systemic anaphylaxis was induced by injection of heat-aggregated human intravenous immunoglobulin and active systemic anaphylaxis after immunization and challenge. Anaphylaxis severity was evaluated based on hypothermia and mortality. The contribution of receptors, mediators, or cell types was assessed based on receptor blockade or depletion. The human-to-mouse low-affinity FcγR locus swap engendered hFcγRIIA/IIB/IIIA/IIIB expression in mice comparable with that seen in human subjects. Knock-in mice were susceptible to passive and active anaphylaxis, accompanied by downregulation of both activating and inhibitory hFcγR expression on specific myeloid cells. The contribution of hFcγRIIA was predominant. Depletion of neutrophils protected against hypothermia and mortality. Basophils contributed to a lesser extent. Anaphylaxis was inhibited by platelet-activating factor receptor or histamine receptor 1 blockade. Low-affinity FcγR locus-switched mice represent an unprecedented model of cognate hFcγR expression. Importantly, IgG-related anaphylaxis proceeds within a native context of activating and inhibitory hFcγRs, indicating that, despite robust hFcγRIIB expression, activating signals can dominate to initiate a severe anaphylactic reaction. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights

  20. Photoprotective Properties of Isothiocyanate and Nitrile Glucosinolate Derivatives From Meadowfoam (Limnanthes alba Against UVB Irradiation in Human Skin Equivalent

    Directory of Open Access Journals (Sweden)

    Evan L. Carpenter

    2018-05-01

    Full Text Available Exposure to ultraviolet B (UVB irradiation of the skin leads to numerous dermatological concerns including skin cancer and accelerated aging. Natural product glucosinolate derivatives, like sulforaphane, have been shown to exhibit chemopreventive and photoprotective properties. In this study, we examined meadowfoam (Limnanthes alba glucosinolate derivatives, 3-methoxybenzyl isothiocyanate (MBITC and 3-methoxyphenyl acetonitrile (MPACN, for their activity in protecting against the consequences of UV exposure. To that end, we have exposed human primary epidermal keratinocytes (HPEKs and 3D human skin reconstructed in vitro (EpiDermTM FT-400 to UVB insult and investigated whether MBITC and MPACN treatment ameliorated the harmful effects of UVB damage. Activity was determined by the compounds’ efficacy in counteracting UVB-induced DNA damage, matrix-metalloproteinase (MMP expression, and proliferation. We found that in monolayer cultures of HPEK, MBITC and MPACN did not protect against a UVB-induced loss in proliferation and MBITC itself inhibited cell proliferation. However, in human reconstructed skin-equivalents, MBITC and MPACN decrease epidermal cyclobutane pyrimidine dimers (CPDs and significantly reduce total phosphorylated γH2A.X levels. Both MBITC and MPACN inhibit UVB-induced MMP-1 and MMP-3 expression indicating their role to prevent photoaging. Both compounds, and MPACN in particular, showed activity against UVB-induced proliferation as indicated by fewer epidermal PCNA+ cells and prevented UVB-induced hyperplasia as determined by a reduction in reconstructed skin epidermal thickness (ET. These data demonstrate that MBITC and MPACN exhibit promising anti-photocarcinogenic and anti-photoaging properties in the skin microenvironment and could be used for therapeutic interventions.

  1. Radiological assessment of the impact on human populations and the environment of the 1949 to 1982 dumping of low and intermediate level radioactive waste in the deep North-East Atlantic

    International Nuclear Information System (INIS)

    Chartier, M.; Menard, F.

    1990-12-01

    A thorough radiological assessment of the impact of the 1949 to 1982 dumping of low- and intermediate- level radioactive waste in the deep North-East Atlantic is performed with the numerical compartmental REJMAR model. The calculations include the assessment of the dose equivalent to the individuals of a theoretical critical group through a large set of pathways, and the collective dose to mankind through the ingestion pathways. The complete dumping performed in the deep North-East Atlantic is taken into account. The assumptions of biological short-circuit through marin food chains are tested. The order of magnitude of the dose delivered to marine organisms living near the dumping site is assessed [fr

  2. A preliminary evaluation of alternatives for disposal of INEL low-level waste and low-level mixed waste

    International Nuclear Information System (INIS)

    Smith, T.H.; Roesener, W.S.; Jorgenson-Waters, M.J.

    1993-07-01

    The Mixed and Low-Level Waste Disposal Facility (MLLWDF) project was established in 1992 by the US Department of Energy Idaho Operations Office to provide enhanced disposal capabilities for Idaho National Engineering Laboratory (INEL) low-level mixed waste and low-level waste. This Preliminary Evaluation of Alternatives for Disposal of INEL Low-Level Waste and Low-Level Mixed Waste identifies and evaluates-on a preliminary, overview basis-the alternatives for disposal of that waste. Five disposal alternatives, ranging from of no-action'' to constructing and operating the MLLWDF, are identified and evaluated. Several subalternatives are formulated within the MLLWDF alternative. The subalternatives involve various disposal technologies as well as various scenarios related to the waste volumes and waste forms to be received for disposal. The evaluations include qualitative comparisons of the projected isolation performance for each alternative, and facility, health and safety, environmental, institutional, schedule, and rough order-of-magnitude life-cycle cost comparisons. The performance of each alternative is evaluated against lists of ''musts'' and ''wants.'' Also included is a discussion of other key considerations for decisionmaking. The analysis of results indicated further study is necessary to obtain the best estimate of long-term future waste volume and characteristics from the INEL Environmental Restoration activities and the expanded INEL Decontamination and Decommissioning Program

  3. Equivalent Lagrangians

    International Nuclear Information System (INIS)

    Hojman, S.

    1982-01-01

    We present a review of the inverse problem of the Calculus of Variations, emphasizing the ambiguities which appear due to the existence of equivalent Lagrangians for a given classical system. In particular, we analyze the properties of equivalent Lagrangians in the multidimensional case, we study the conditions for the existence of a variational principle for (second as well as first order) equations of motion and their solutions, we consider the inverse problem of the Calculus of Variations for singular systems, we state the ambiguities which emerge in the relationship between symmetries and conserved quantities in the case of equivalent Lagrangians, we discuss the problems which appear in trying to quantize classical systems which have different equivalent Lagrangians, we describe the situation which arises in the study of equivalent Lagrangians in field theory and finally, we present some unsolved problems and discussion topics related to the content of this article. (author)

  4. Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

    Science.gov (United States)

    Olson, Sandra

    2011-01-01

    To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

  5. A nationwide low-level waste management system

    International Nuclear Information System (INIS)

    1985-01-01

    The National Governors' Association, in conjunction with the Department of Energy's National Low-Level Waste Management Program, invited various representatives of states, regions, and federal agencies to comment on their perceptions of what major features would constitute a nationwide low-level waste management system. Three meetings were conducted and this report summarizes results of those meetings. The Low-Level Radioactive Waste Policy Act of 1980 placed primary responsibility on the states for disposal of low-level waste. Although initial efforts of states have been directed toward establishing compacts, it is evident that a successful long term system requires significant cooperation and communication among states, regions, federal agencies, and Congress

  6. The Drigg low-level waste site

    International Nuclear Information System (INIS)

    1992-01-01

    Safe disposal of waste is a vital aspect of any industrial operation whether it be production of plastics, steel or chemicals or handling of radioactive materials. Appropriate methods must be used in every case. Radioactive waste falls into three distinct categories - high, intermediate and low-level. It is the solid low-level waste making up over 90% of the total which this booklet discusses. British Nuclear Fuels plc (BNFL) operates a site for the disposal of solid low-level waste at Driggs, some six kilometres south of Sellafield in West Cumbria. The daily operations and control of the site, the responsibility of the BNFL Waste Management Unit is described. (author)

  7. Treatment of burning mouth syndrome with a low-level energy diode laser.

    Science.gov (United States)

    Yang, Hui-Wen; Huang, Yu-Feng

    2011-02-01

    To test the therapeutic efficacy of low-level energy diode laser on burning mouth syndrome. Burning mouth syndrome is characterized by burning and painful sensations in the mouth, especially the tongue, in the absence of significant mucosal abnormalities. Although burning mouth syndrome is relatively common, little is known regarding its etiology and pathophysiology. As a result, no treatment is effective in all patients. Low-level energy diode laser therapy has been used in a variety of chronic and acute pain conditions, including neck, back and myofascial pain, degenerative osteoarthritis, and headache. A total of 17 patients who had been diagnosed with burning mouth syndrome were treated with an 800-nm wavelength diode laser. A straight handpiece was used with an end of 1-cm diameter with the fiber end standing 4 cm away from the end of handpiece. When the laser was applied, the handpiece directly contacted or was immediately above the symptomatic lingual surface. The output used was 3 W, 50 msec intermittent pulsing, and a frequency of 10 Hz, which was equivalent to an average power of 1.5 W/cm(2) (3 W × 0.05 msec × 10 Hz = 1.5 W/cm(2)). Depending on the involved area, laser was applied to a 1-cm(2) area for 70 sec until all involved area was covered. Overall pain and discomfort were analyzed with a 10-cm visual analogue scale. All patients received diode laser therapy between one and seven times. The average pain score before the treatment was 6.7 (ranging from 2.9 to 9.8). The results showed an average reduction in pain of 47.6% (ranging from 9.3% to 91.8%). The burning sensation remained unchanged for up to 12 months. Low-level energy diode laser may be an effective treatment for burning mouth syndrome.

  8. Acoustic characterization of a nonlinear vibroacoustic absorber at low frequencies and high sound levels

    Science.gov (United States)

    Chauvin, A.; Monteil, M.; Bellizzi, S.; Côte, R.; Herzog, Ph.; Pachebat, M.

    2018-03-01

    A nonlinear vibroacoustic absorber (Nonlinear Energy Sink: NES), involving a clamped thin membrane made in Latex, is assessed in the acoustic domain. This NES is here considered as an one-port acoustic system, analyzed at low frequencies and for increasing excitation levels. This dynamic and frequency range requires a suitable experimental technique, which is presented first. It involves a specific impedance tube able to deal with samples of sufficient size, and reaching high sound levels with a guaranteed linear response thank's to a specific acoustic source. The identification method presented here requires a single pressure measurement, and is calibrated from a set of known acoustic loads. The NES reflection coefficient is then estimated at increasing source levels, showing its strong level dependency. This is presented as a mean to understand energy dissipation. The results of the experimental tests are first compared to a nonlinear viscoelastic model of the membrane absorber. In a second step, a family of one degree of freedom models, treated as equivalent Helmholtz resonators is identified from the measurements, allowing a parametric description of the NES behavior over a wide range of levels.

  9. Approved Drug Products with Therapuetic Equivalence Evaluations (Orange Book)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The publication Approved Drug Products with Therapeutic Equivalence Evaluations (the List, commonly known as the Orange Book) identifies drug products approved on...

  10. Understanding and characterisation of the risks to human health from exposure to low levels of radiation

    International Nuclear Information System (INIS)

    Goodhead, D. T.

    2009-01-01

    Exposure to ionising radiation can lead to a wide variety of health effects. Cancer is judged to be the main risk from radiation at low doses and low dose rates, and controlling this risk has been the main factor in developing radiation protection practice. Conventional paradigms of radiobiology and radiation carcinogenesis have served to guide extrapolations of epidemiological data on exposed human populations, so as to estimate risks at low doses and low dose rates, to other types of ionising radiation and to non-uniform exposures. These paradigms are founded on a century of experimental and theoretical studies, but nevertheless there remain many uncertainties. Major assumptions and simplifications have been introduced to achieve a practical system of additive doses (and implied risks) for radiation protection. Advancing epidemiological studies and experimental research continue to reduce uncertainties in some areas while, in others, they raise new challenges to the generality and applicability of the conventional paradigms. (authors)

  11. The consequences of a reduction in the administratively applied maximum annual dose equivalent level for an individual in a group of occupationally exposed workers

    International Nuclear Information System (INIS)

    Harrison, N.T.

    1980-02-01

    An analysis is described for predicting the consequences of a reduction in the administratively applied maximum dose equivalent level to individuals in a group of workers occupationally exposed to ionising radiations, for the situation in which no changes are made to the working environment. This limitation of the maximum individual dose equivalent is accommodated by allowing the number of individuals in the working group to increase. The derivation of the analysis is given, together with worked examples, which highlight the important assumptions that have been made and the conclusions that can be drawn. The results are obtained in the form of the capacity of the particular working environment to accommodate the limitation of the maximum individual dose equivalent, the increase in the number of workers required to carry out the productive work and any consequent increase in the occupational collective dose equivalent. (author)

  12. The semi-empirical low-level background statistics

    International Nuclear Information System (INIS)

    Tran Manh Toan; Nguyen Trieu Tu

    1992-01-01

    A semi-empirical low-level background statistics was proposed. The one can be applied to evaluated the sensitivity of low background systems, and to analyse the statistical error, the 'Rejection' and 'Accordance' criteria for processing of low-level experimental data. (author). 5 refs, 1 figs

  13. Characterization of tissue-equivalent materials for use in construction of physical phantoms

    International Nuclear Information System (INIS)

    Souza, Edvan V. de; Oliveira, Alex C.H. de; Vieira, Jose W.; Lima, Fernando R.A.

    2013-01-01

    Phantoms are physical or computational models used to simulate the transport of ionizing radiation, their interactions with human body tissues and evaluate the deposition of energy. Depending on the application, you can build phantoms of various types and features. The physical phantoms are made of materials with behavior similar to human tissues exposed to ionizing radiation, the so-called tissue-equivalent materials. The characterization of various tissue-equivalent materials is important for the choice of materials to be used is appropriate, seeking a better cost-benefit ratio. The main objective of this work is to produce tables containing the main characteristics of tissue-equivalent materials. These tables were produced in Microsoft Office Excel. Among the main features of tissue-equivalent materials that were added to the tables, are density, chemical composition, physical state, chemical stability and solubility. The main importance of this work is to contribute to the construction of high-quality physical phantoms and avoid the waste of materials

  14. Equivalent circuit-level model of quantum cascade lasers with integrated hot-electron and hot-phonon effects

    Science.gov (United States)

    Yousefvand, H. R.

    2017-12-01

    We report a study of the effects of hot-electron and hot-phonon dynamics on the output characteristics of quantum cascade lasers (QCLs) using an equivalent circuit-level model. The model is developed from the energy balance equation to adopt the electron temperature in the active region levels, the heat transfer equation to include the lattice temperature, the nonequilibrium phonon rate to account for the hot phonon dynamics and simplified two-level rate equations to incorporate the carrier and photon dynamics in the active region. This technique simplifies the description of the electron-phonon interaction in QCLs far from the equilibrium condition. Using the presented model, the steady and transient responses of the QCLs for a wide range of sink temperatures (80 to 320 K) are investigated and analysed. The model enables us to explain the operating characteristics found in QCLs. This predictive model is expected to be applicable to all QCL material systems operating in pulsed and cw regimes.

  15. Technical responsibilities in low-level waste disposal

    International Nuclear Information System (INIS)

    Murray, R.L.; Walker, C.K.

    1989-01-01

    North Carolina will be the host state for a low-level radioactive waste (LLRW) disposal facility serving the Southeast Compact for 20 yr beginning in 1993. Primary responsibility for the project rests with the North Carolina Low-Level Radioactive Waste Management Authority, a citizen board. The North Carolina project embodies a unique combination of factors that places the authority in a position to exercise technical leadership in the LLRW disposal field. First, the Southeast Compact is the largest in the United States in terms of area, population, and waste generation. second, it is in a humid rather than an arid region. Third, the citizens of the state are intensely interested in preserving life style, environment, and attractiveness of the region to tourists and are especially sensitive to the presence of waste facilities of any kind. Finally, disposal rules set by the Radiation Protection Commission and enforced by the Radiation Protection Section are stricter than the U.S. Nuclear Regulatory Commission's 10CFR61. These four factors support the authority's belief that development of the facility cannot be based solely on engineering and economics, but that social factors, including perceptions of human risk, concerns for the environment, and opinions about the desirability of hosting a facility, should be integral to the project. This philosophy guides the project's many technical aspects, including site selection, site characterization, technology selection and facility design, performance assessment modeling, and waste reduction policies. Each aspect presents its own unique problems

  16. Acceptance criteria for deposition of low-level and intermediate-level radiation levels radioactive wastes

    International Nuclear Information System (INIS)

    2002-09-01

    This norm establishes the criteria for acceptance low and intermediate radiation level for safe deposition in repositories, for assuring the protection of workers, population and environment against the hazardous effects of the ionizing radiations. The criteria of this norm applies to the low and intermediate radiation levels

  17. Foreword: Biomonitoring Equivalents special issue.

    Science.gov (United States)

    Meek, M E; Sonawane, B; Becker, R A

    2008-08-01

    The challenge of interpreting results of biomonitoring for environmental chemicals in humans is highlighted in this Foreword to the Biomonitoring Equivalents (BEs) special issue of Regulatory Toxicology and Pharmacology. There is a pressing need to develop risk-based tools in order to empower scientists and health professionals to interpret and communicate the significance of human biomonitoring data. The BE approach, which integrates dosimetry and risk assessment methods, represents an important advancement on the path toward achieving this objective. The articles in this issue, developed as a result of an expert panel meeting, present guidelines for derivation of BEs, guidelines for communication using BEs and several case studies illustrating application of the BE approach for specific substances.

  18. Low-level-waste-disposal methodologies

    International Nuclear Information System (INIS)

    Wheeler, M.L.; Dragonette, K.

    1981-01-01

    This report covers the followng: (1) history of low level waste disposal; (2) current practice at the five major DOE burial sites and six commercial sites with dominant features of these sites and radionuclide content of major waste types summarized in tables; (3) site performance with performance record on burial sites tabulated; and (4) proposed solutions. Shallow burial of low level waste is a continuously evolving practice, and each site has developed its own solutions to the handling and disposal of unusual waste forms. There are no existing national standards for such disposal. However, improvements in the methodology for low level waste disposal are occurring on several fronts. Standardized criteria are being developed by both the Nuclear Regulatory Commission (NRC) and by DOE. Improved techniques for shallow burial are evolving at both commercial and DOE facilities, as well as through research sponsored by NRC, DOE, and the Environmental Protection Agency. Alternatives to shallow burial, such as deeper burial or the use of mined cavities is also being investigated by DOE

  19. Application of conventional and FPG staining for the analysis of chromosome aberrations induced by low levels of dose in human lymphocytes

    International Nuclear Information System (INIS)

    Wagner, R.; Schmid, E.; Bauchinger, M.

    1983-01-01

    Human peripheral lymphocytes were irradiated with 0.05-0.5 Gy of 220 keV X-rays. After application of either a conventional or the fluorescence plus Giemsa (FPG) staining technique, the dose response for dicentrics and acentrics was studied. The analysis of exclusively first-division cells (M 1 ), carried out by the FPG method, revealed significantly higher aberration yields as compared with the results of the conventional method. The data from M 1 cells support the assumption of a linear dose response for both dicentrics and acentrics. The results are discussed with regard to the application of chromosome analyses for a cytogenetic dosimetry after exposure to low levels of ionizing radiation. (orig.)

  20. Issue briefs on low-level radioactive wastes

    International Nuclear Information System (INIS)

    1981-01-01

    This report contains 4 Issue Briefs on low-level radioactive wastes. They are entitled: Handling, Packaging, and Transportation, Economics of LLW Management, Public Participation and Siting, and Low Level Waste Management

  1. Assessment of ambient dose equivalent rate performance of an automatic survey meter as an instrument to quantify the presence of radiation in soils

    CERN Document Server

    Yoshimura, E M; Okuno, E

    2002-01-01

    Those who work in radiation protection are faced with various quantities that were created to account for the effects of ionizing radiation in the human body. As far as the experimental point of view is concerned, each available equipment is planned to measure a distinct quantity, for a specific radiation protection application, and it is not always clear which one it is. This paper shows a series of tests, planned and applied to a portable gamma ray spectrometer, in order to assure that the monitoring low dose levels of radiation with it is reliable. The equipment is fully automated and does not allow modifications of the conversion factors from counts to ambient dose equivalent. It is therefore necessary to assure that the values provided by the equipment are correct and refer to the actual situation one expects to find in practice. The system is based on an NaI(Tl) scintillation detector, mounted with its electronics in a portable case, suitable for field measurements. It measures ambient dose equivalent r...

  2. Electrocortical correlates of human level-ground, slope, and stair walking.

    Directory of Open Access Journals (Sweden)

    Trieu Phat Luu

    Full Text Available This study investigated electrocortical dynamics of human walking across different unconstrained walking conditions (i.e., level ground (LW, ramp ascent (RA, and stair ascent (SA. Non-invasive active-electrode scalp electroencephalography (EEG signals were recorded and a systematic EEG processing method was implemented to reduce artifacts. Source localization combined with independent component analysis and k-means clustering revealed the involvement of four clusters in the brain during the walking tasks: Left and Right Occipital Lobe (LOL, ROL, Posterior Parietal Cortex (PPC, and Central Sensorimotor Cortex (SMC. Results showed that the changes of spectral power in the PPC and SMC clusters were associated with the level of motor task demands. Specifically, we observed α and β suppression at the beginning of the gait cycle in both SA and RA walking (relative to LW in the SMC. Additionally, we observed significant β rebound (synchronization at the initial swing phase of the gait cycle, which may be indicative of active cortical signaling involved in maintaining the current locomotor state. An increase of low γ band power in this cluster was also found in SA walking. In the PPC, the low γ band power increased with the level of task demands (from LW to RA and SA. Additionally, our results provide evidence that electrocortical amplitude modulations (relative to average gait cycle are correlated with the level of difficulty in locomotion tasks. Specifically, the modulations in the PPC shifted to higher frequency bands when the subjects walked in RA and SA conditions. Moreover, low γ modulations in the central sensorimotor area were observed in the LW walking and shifted to lower frequency bands in RA and SA walking. These findings extend our understanding of cortical dynamics of human walking at different level of locomotion task demands and reinforces the growing body of literature supporting a shared-control paradigm between spinal and

  3. Construction of Anterior Hemi-Corneal Equivalents Using Nontransfected Human Corneal Cells and Transplantation in Dog Models.

    Science.gov (United States)

    Xu, Bin; Song, Zhan; Fan, Tingjun

    2017-11-01

    Tissue-engineered human anterior hemi-cornea (TE-aHC) is a promising equivalent for treating anterior lamellar keratopathy to surmount the severe shortage of donated corneas. This study was intended to construct a functional TE-aHC with nontransfected human corneal stromal (ntHCS) and epithelial (ntHCEP) cells using acellular porcine corneal stromata (aPCS) as a carrier scaffold, and evaluate its biological functions in a dog model. To construct a TE-aHC, ntHCS cells were injected into an aPCS scaffold and cultured for 3 days; then, ntHCEP cells were inoculated onto the Bowman's membrane of the scaffold and cultured for 5 days under air-liquid interface condition. After its morphology and histological structure were characterized, the constructed TE-aHC was transplanted into dog eyes via lamellar keratoplasty. The corneal transparency, thickness, intraocular pressure, epithelial integrity, and corneal regeneration were monitored in vivo, and the histological structure and histochemical property were examined ex vivo 360 days after surgery, respectively. The results showed that the constructed TE-aHC was highly transparent and composed of a corneal epithelium of 7-8 layer ntHCEP cells and a corneal stroma of regularly aligned collagen fibers and well-preserved glycosaminoglycans with sparsely distributed ntHCS cells, mimicking a normal anterior hemi-cornea (aHC). Moreover, both ntHCEP and ntHCS cells maintained positive expression of their marker and functional proteins. After transplantation into dog eyes, the constructed TE-aHC acted naturally in terms of morphology, structure and inherent property, and functioned well in maintaining corneal clarity, thickness, normal histological structure, and composition in dog models by reconstructing a normal aHC, which could be used as a promising aHC equivalent in corneal regenerative medicine and aHC disorder therapy. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Low-level waste forum meeting reports

    International Nuclear Information System (INIS)

    1992-01-01

    This paper provides highlights from the spring meeting of the Low Level Radioactive Waste Forum. Topics of discussion included: state and compact reports; New York's challenge to the constitutionality of the Low-Level Radioactive Waste Amendments Act of 1985; DOE technical assistance for 1993; interregional import/export agreements; Department of Transportation requirements; superfund liability; nonfuel bearing components; NRC residual radioactivity criteria

  5. Characterization of tissues equivalent to the human body by the Monte Carlo method for X-rays

    International Nuclear Information System (INIS)

    Vega R, J.; Huamani T, Y.; Mullisaca P, A. F.; Yauri C, L.

    2017-10-01

    There is a need to have materials equivalent to the human body that have the appropriate characteristics to be used as a substitute tissue in the clinical practices of radio-diagnosis, radiotherapy. In Arequipa, Peru, there are two health centers in radiotherapy applications, one with a Theratron Co-60 gamma irradiator and another with Elekta Linac; the Medical Physics Area of the School of Physics of the National University of San Agustin de Arequipa, were four equivalent materials based on epoxy resin, phenolitic spheres, calcium carbonate, etc. were built, such as bone tissue, soft tissue, adipose and lung tissue compared with water, whit the purpose of studying and applying them in future clinical applications. In this work we describe its physical and dosimetric characterization to determine its use as an equivalent material or manikin. The materials are 1 cm thick and 30 cm in diameter, the materials are non-malleable solids, they do not degrade, they have stability in their consistency due to temperature and irradiation, they are not toxic in their use, determining densities from 0.32 g/cm 3 for the lung tissue to 1.8 g/cm 3 for the bone material. These materials were analyzed by scanning electron microscopy, giving the percentages by weight of the elements found to determine their effective atomic number, the physical analysis to determine their mass absorption and energy coefficients, which were studied for energy photons between 1 KeV at 20 MeV. The simulation of the equivalent materials and the physical and dosimetric study were found using the code Penelope 2008 Monte Carlo method and validated by the Nist database. The results obtained according to their coefficients of mass attenuation of each material, show lung, bone, soft and adipose tissue with differences with respect to the same Nist materials. The range maximum and minimum Rd deviation found was 35.65 - 3.16 for bone, 28.5 - 6.74 for lung, 33.78 - 9.06 for soft tissue and 86.42 - 1.28 for

  6. The low-level radioactive waste crisis

    International Nuclear Information System (INIS)

    Bord, R.J.

    1988-01-01

    According to the author, the goals of the 1980 Low-Level Radioactive Waste Policy Act have not been met. That act stipulated that regional disposal sites were to be established by 1986. To date, no new sites have been established and none are anywhere near the construction phase. Congress, responding to existing impasse, has extended the deadline to the end of 1992 with the passage of the Low-Level Radioactive Waste Policy Act. The reasons for the impasse are no mystery: local intransigence regarding waste of any kind, public fears of radiation hazards, and politicians' anxieties about their constituents' fears. The focus of this paper is the viability of ongoing attempts to overcome public intransigence in the case of disposal siting for low-level radioactive waste (LLRW)

  7. Global distribution and seasonal variability of coastal low-level jets derived from ERA-Interim reanalysis

    Directory of Open Access Journals (Sweden)

    Raza Ranjha

    2013-08-01

    Full Text Available A low-level wind maximum is often found over the oceans near many coasts around the world. These Coastal Low-Level Jets (CLLJs play an important role in the coastal weather and have significant impacts on regional climate and ecology as well as on a number of human activities. The presence of CLLJs is related to various local circumstances such as land-sea temperature contrasts, upwelling, coastal terrain, orientation of the coast, and so on, but also to the large-scale atmospheric dynamics. This makes studies of CLLJs not only interesting but also challenging. In this study, based on ERA-Interim reanalysis data, the global distribution, spatio-temporal structure and the seasonal variability of CLLJs are documented. Seasonal data from 1980 to 2011 are used to identify areas where CLLJs are frequently found in the lowest 2 km, following criteria based on the vertical profiles of wind speed and temperature. The results are analysed to highlight the fundamental aspects and distinctive features of the CLLJs across the globe, including their occurrence rate, jet height, maximum wind speed and horizontal extent. Global maps of CLLJs are constructed for the summer and winter seasons. The west coasts of North America, the Iberian Peninsula, north-western Africa and the south-eastern coast of the Arabian Peninsula make up the Northern Hemispheric CLLJ regions, while the west coasts of South America, Australia, and southern Africa comprise the South Hemispheric equivalents. The existence and characteristics of CLLJs along the southern coast of Oman and the western coast of the Iberian Peninsula regions are also discussed, not fully envisaged before in the context of CLLJs. The highest occurrence of CLLJs is found during the summer in both hemispheres, and the coast of Oman has the globally highest CLLJ frequency, with also the highest maximum wind speeds. The most commonly found CLLJ has a maximum wind speed between 9 and 15 m s−1, and occurs at

  8. Low-level radiation: a review of current estimates of hazards to human populations

    International Nuclear Information System (INIS)

    Myers, D.K.

    1977-12-01

    Mankind has always lived with low levels of ionizing radiation from natural sources. This ionizing radiation may induce cancers in irradiated persons and genetic defects in the descendents of irradiated persons. The internationally accepted estimates of risks suggest that the numbers of cancers and genetic defects induced in the general population by natural background radiation are not more than about 1% of the numbers of cancers and genetic defects normally present in the general population. The added risks to the general public due to any prospective nuclear power program are minute compared to those from background radiation. At the maximum permissible levels of radiation exposures for occupational workers, the predicted number of fatal cancers induced would lead to a reduction in average life-span from 73.0 years to about 72.7 years. Since occupational exposures are usually much less than maximum permissible levels, the risks are correspondingly reduced. These occupational risks are comparable to those in most other industries and occupations. Some areas of uncertainty in the accepted risk estimates are discussed in detail in this review. (author)

  9. Low-Level Radioactive Waste temporary storage issues

    International Nuclear Information System (INIS)

    1992-04-01

    The Low-Level Radioactive Waste Policy Act of 1980 gave responsibility for the disposal of commercially generated low-level radioactive waste to the States. The Low-Level Radioactive Waste Policy Amendments Act of 1985 attached additional requirements for specific State milestones. Compact regions were formed and host States selected to establish disposal facilities for the waste generated within their borders. As a result of the Low-Level Radioactive Waste Policy Amendments Act of 1985, the existing low-level radioactive waste disposal sites will close at the end of 1992; the only exception is the Richland, Washington, site, which will remain open to the Northwest Compact region only. All host States are required to provide for disposal of low-level radioactive waste by January 1, 1996. States also have the option of taking title to the waste after January 1, 1993, or taking title by default on January 1, 1996. Low-level radioactive waste disposal will not be available to most States on January 1, 1993. The most viable option between that date and the time disposal is available is storage. Several options for storage can be considered. In some cases, a finite storage time will be permitted by the Nuclear Regulatory Commission at the generator site, not to exceed five years. If disposal is not available within that time frame, other options must be considered. There are several options that include some form of extension for storage at the generator site, moving the waste to an existing storage site, or establishing a new storage facility. Each of these options will include differing issues specific to the type of storage sought

  10. A low-level diode laser therapy reduces the lipopolysaccharide (LPS)-induced periodontal ligament cell inflammation

    International Nuclear Information System (INIS)

    Huang, T H; Chen, C C; Liu, S L; Lu, Y C; Kao, C T

    2014-01-01

    The purpose of this study was to investigate the cytologic effects of inflammatory periodontal ligament cells in vitro after low-level laser therapy. Human periodontal ligament cells were cultured, exposed to lipopolysaccharide and subjected to low-level laser treatment of 5 J cm −2 or 10 J cm −2 using a 920 nm diode laser. A periodontal ligament cell attachment was observed under a microscope, and the cell viability was quantified by a mitochondrial colorimetric assay. Lipopolysaccharide-treated periodontal ligament cells were irradiated with the low-level laser, and the expression levels of several inflammatory markers, iNOS, TNF-α and IL-1, and pErk kinase, were analyzed by reverse transcription polymerase chain reaction and western blot. The data were collected and analyzed by one-way analysis of variance; p < 0.05 indicated a statistically significant difference. The low-level laser treatment of periodontal ligament cells increased their ability to attach and survive. After irradiation, the expression levels of iNOS, TNF-α and IL-1 in lipopolysaccharide-exposed periodontal ligament cells decreased over time (p < 0.05). In periodontal ligament cells, low-level diode laser treatment increased the cells’ proliferative ability and decreased the expression of the examined inflammatory mediators. (letters)

  11. Stimulus Ratio and Level Dependence of Low- and Mid-Frequency Distortion-Product Otoacoustic Emissions

    DEFF Research Database (Denmark)

    Christensen, Anders Tornvig; Ordoñez, Rodrigo Pizarro; Hammershøi, Dorte

    2014-01-01

    ratios f2/f1 (1.05-1.50) and three stimulus sound pressure levels L1/L2 (65/45, 65/55, 70/60) were measured in each configuration. The DPOAE response was isolated with the discrete Fourier transformation (DFT). The DFT measures the DPOAE response accurately only when the DPOAE frequency and both stimulus...... examples of low-frequency DPOAEs exist in the literature. Overcoming the decreasing response level and increasing noise level with decreasing frequency may provide a non-invasive window into the inner-ear mechanics of low-frequency hearing. Eighteen out of 21 young human adults screened (19-30 years) had......-frequency range. The stimulus level has similar effects in both frequency ranges, that is, the ratio-magnitude response increases and broadens with increasing level. The combined observations could indicate a difference between apical and basal cochlear physiology....

  12. Tritium: a model for low level long-term ionizing radiation exposure

    International Nuclear Information System (INIS)

    Carsten, A.L.

    1984-01-01

    The somatic, cytogenetic and genetic effects of single and chronic tritiated water (HTO) ingestion in mice was investigated. This study serves not only as an evaluation of tritium toxicity (TRITOX) but due to its design involving long-term low concentration ingestion of HTO may serve as a model for low level long-term ionizing radiation exposure in general. Long-term studies involved animals maintained on HTO at concentrations of 0.3 μCi/ml, 1.0 μCi/ml, 3.0 μCi/ml or depth dose equivalent chronic external exposures to 137 Cs gamma rays. Maintenance on 3.0 μCi/ml resulted in no effect on growth, life-time shortening or bone marrow cellularity, but did result in a reduction of bone marrow stem cells, an increase in DLM's in second generation animals maintained on this regimen and cytogenetic effects as indicated by increased sister chromatid exchanges (SCE's) in bone marrow cells, increased chromosome aberrations in the regenerating liver and an increase in micronuclei in red blood cells. Biochemical and microdosimetry studies showed that animals placed on the HTO regimen reached tritium equilibrium in the body water in approximately 17 to 21 days with a more gradual increase in bound tritium. When animals maintained for 180 days on 3.0 μCi/ml HTO were placed on a tap water regimen, the tritium level in tissue dropped from the equilibrium value of 2.02 μCi/ml before withdrawal to 0.001 μCi/ml at 28 days. 18 references

  13. Expression of proliferative and inflammatory markers in a full-thickness human skin equivalent following exposure to the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide

    International Nuclear Information System (INIS)

    Black, Adrienne T.; Hayden, Patrick J.; Casillas, Robert P.; Heck, Diane E.; Gerecke, Donald R.; Sinko, Patrick J.; Laskin, Debra L.; Laskin, Jeffrey D.

    2010-01-01

    Sulfur mustard is a potent vesicant that induces inflammation, edema and blistering following dermal exposure. To assess molecular mechanisms mediating these responses, we analyzed the effects of the model sulfur mustard vesicant, 2-chloroethyl ethyl sulfide, on EpiDerm-FT TM , a commercially available full-thickness human skin equivalent. CEES (100-1000 μM) caused a concentration-dependent increase in pyknotic nuclei and vacuolization in basal keratinocytes; at high concentrations (300-1000 μM), CEES also disrupted keratin filament architecture in the stratum corneum. This was associated with time-dependent increases in expression of proliferating cell nuclear antigen, a marker of cell proliferation, and poly(ADP-ribose) polymerase (PARP) and phosphorylated histone H2AX, markers of DNA damage. Concentration- and time-dependent increases in mRNA and protein expression of eicosanoid biosynthetic enzymes including COX-2, 5-lipoxygenase, microsomal PGE 2 synthases, leukotriene (LT) A 4 hydrolase and LTC 4 synthase were observed in CEES-treated skin equivalents, as well as in antioxidant enzymes, glutathione S-transferases A1-2 (GSTA1-2), GSTA3 and GSTA4. These data demonstrate that CEES induces rapid cellular damage, cytotoxicity and inflammation in full-thickness skin equivalents. These effects are similar to human responses to vesicants in vivo and suggest that the full thickness skin equivalent is a useful in vitro model to characterize the biological effects of mustards and to develop potential therapeutics.

  14. National low-level waste management program radionuclide report series, Volume 14: Americium-241

    International Nuclear Information System (INIS)

    Winberg, M.R.; Garcia, R.S.

    1995-09-01

    This report, Volume 14 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of americium-241 ( 241 Am). This report also includes discussions about waste types and forms in which 241 Am can be found and 241 Am behavior in the environment and in the human body

  15. National Low-Level Waste Management Program radionuclide report series. Volume 13, Curium-242

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-08-01

    This report, Volume 13 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of curium-242 ( 242 Cm). This report also includes discussions about waste types and forms in which 242 Cm can be found and 242 Cm behavior in the environment and in the human body

  16. Low-level laser therapy for pain relief after episiotomy: a double-blind randomised clinical trial.

    Science.gov (United States)

    Santos, Jaqueline de O; de Oliveira, Sonia M J V; da Silva, Flora M B; Nobre, Moacyr R C; Osava, Ruth H; Riesco, Maria L G

    2012-12-01

    To evaluate the effectiveness of a low-level laser therapy for pain relief in the perineum following episiotomy during childbirth. Laser irradiation is a painless and non-invasive therapy for perineal pain treatment and its effects have been investigated in several studies, with no clear conclusion on its effectiveness. A double-blind randomised controlled clinical trial. One hundred and fourteen women who underwent right mediolateral episiotomies during vaginal birth in an in-hospital birthing centre in São Paulo, Brazil and reported pain ≥ 3 on a numeric scale (0-10) were randomised into three groups of 38 women each: two experimental groups (treated with red and infrared laser) and a control group. The experimental groups were treated with laser applied at three points directly on the episiotomy after suturing in a single session between 6-56 hours postpartum. We used a diode laser with wavelengths of 660 nm (red laser) and 780 nm (infrared laser). The control group participants underwent all laser procedures, excluding the emission of irradiation. The participants and the pain scores evaluator were blinded to the type of intervention. The perineal pain scores were assessed at three time points: before, immediately after and 30 minutes after low-level laser therapy. The comparison of perineal pain between the three groups showed no significant differences in the three evaluations (p = 0.445), indicating that the results obtained in the groups treated with low-level laser therapy were equivalent to the control group. Low-level laser therapy did not decrease the intensity of perineal pain reported by women who underwent right mediolateral episiotomy. The effect of laser in perineal pain relief was not demonstrated in this study. The dosage may not have been sufficient to provide relief from perineal pain after episiotomy during a vaginal birth. © 2012 Blackwell Publishing Ltd.

  17. Assessment of LANL solid low-level waste management documentation

    International Nuclear Information System (INIS)

    Klein, R.B.; Jennrich, E.A.; Lund, D.M.; Danna, J.G.; Davis, K.D.; Rutz, A.C.

    1991-04-01

    DOE Order 5820.2A requires that a system performance assessment be conducted to assure efficient and compliant management of all radioactive waste. The objective of this report is to determine the present status of the Radioactive Waste Operations Section's capabilities regarding preparation and maintenance of appropriate criteria, plans and procedures and identify particular areas where these documents are not presently in existence or being fully implemented. DOE Order 5820.2A, Radioactive Waste Management, Chapter III sets forth the requirements and guidelines for preparation and implementation of criteria, plans and procedures to be utilized in the management of solid low-level waste. The documents being assessed in this report are: Solid Low-Level Waste Acceptance Criteria, Solid Low-Level Waste Characterization Plan, Solid Low-Level Waste Certification Plan, Solid Low-Level Waste Acceptance Procedures, Solid Low-Level Waste Characterization Procedures, Solid Low-Level Waste Certification Procedures, Solid Low-Level Waste Training Procedures, and Solid Low-Level Waste Recordkeeping Procedures. Suggested outlines for these documents are presented as Appendix A

  18. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  19. Impact of low-level radiation with special reference to tritium in environment

    International Nuclear Information System (INIS)

    Bhatia, A.L.

    2005-01-01

    trend of acclimatization to tritium exposure is always there along with the presence of radiation-induced repair mechanism. But the danger is that the low level exposure may effect in unpredictable ways not only human kind but also its evolving process which may or may not have visible and beneficial (?) influence, what people are calling hormesis. They will act not only on people, but on those biological systems which support us. Because these changes may be beyond the ability of scientists to judge, and in so many disparate ways, we will not notice the decline in the spiritual and physical quality of our world. When finally the effects of this process are so bad that no one can disagree, it will be too late to put the genie back in the bottle. In biological systems the same degree of damage has not been produced by the same absorbed dose of different types of radiation. This difference in the radiobiological effectiveness (RBE) needs to be taken into account if we wish to add doses of different radiation to obtain the total biologically effective dose. For this, the absorbed dose of each type of radiation is required to be multiplied by a Quality Factor (QF). For the sake of simplicity, QF for tritium has been assigned a value of unity (ICRP, 1977). Radiotoxic effects of long term tritium exposure are consistent and apparently higher with those expected from an equivalent absorbed dose from external X-irradiation. Hence, a possibility for a higher RBE for tritium can not be ruled out. Four main areas of tritium studies are proposed for the education and careful evaluation:- (1) Specific models and their validity and suitability to predict environmental transfer of tritium released from various sources especially from thermonuclear devices. (2) The organically bound tritium (OBT) in the food chain and its possible biological consequences (3) The need for evaluation of the chemical form of tritium in environmental samples and their fate after interaction

  20. National Low-Level Waste Management Program radionuclide report series. Volume 13, Curium-242

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.

    1995-08-01

    This report, Volume 13 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of curium-242 ({sup 242}Cm). This report also includes discussions about waste types and forms in which {sup 242}Cm can be found and {sup 242}Cm behavior in the environment and in the human body.

  1. Obesity and Low-Grade Inflammation Increase Plasma Follistatin-Like 3 in Humans

    DEFF Research Database (Denmark)

    Brandt, Claus; Pedersen, Maria; Rinnov, Anders

    2014-01-01

    , plasma leptin, fasting insulin, and HOMA B and negatively with HOMA S. Furthermore plasma fstl3 correlated positively with plasma TNF-α and IL-6 levels. Infusion of LPS and TNF-α, but not IL-6 and insulin, increased plasma fstl3 in humans. CONCLUSION: Plasma fstl3 is increased in obese subjects......BACKGROUND: Rodent models suggest that follistatin-like 3 (fstl3) is associated with diabetes and obesity. In humans, plasma fstl3 is reduced with gestational diabetes. In vitro, TNF-α induces fstl3 secretion, which suggests a link to inflammation. OBJECTIVE: To elucidate the association between...... plasma fstl3 and obesity, insulin resistance, and low-grade inflammation in humans. STUDY DESIGN: Plasma fstl3 levels were determined in a cross-sectional study including three groups: patients with type 2 diabetes, impaired glucose tolerance, and healthy controls. In addition, lipopolysaccharide (LPS...

  2. Generation, transport and conduct of radioactive wastes of low and intermediate level

    International Nuclear Information System (INIS)

    Lizcano, D.; Jimenez, J.

    2005-01-01

    The technological development of the last decades produced an increment in the application of the radiations in different human activities. The effect of it has been it the production of radioactive wastes of all the levels. In Mexico, some of the stages of the administration of the waste of low and intermediate level have not been completely resolved, as the case of the treatment and the final storage. In this work aspects of the generation, the transport and the administration of radioactive waste of low and intermediate level produced in the non energy applications from the radioactive materials to national level, indicating the generated average quantities, transported and tried annually by the National Institute of Nuclear Research (ININ). The main generators of wastes in Mexico, classified according to the activity in which the radioactive materials are used its are listed. Some of the main processes of treatment of radioactive wastes broadly applied in the world and those that are used at the moment in our country are also presented. (Author)

  3. Low level radioactive waste disposal

    International Nuclear Information System (INIS)

    Balaz, J.; Chren, O.

    2015-01-01

    The Mochovce National Radwaste Repository is a near surface multi-barrier disposal facility for disposal of processed low and very low level radioactive wastes (radwastes) resulting from the operation and decommissioning of nuclear facilities situated in the territory of the Slovak Republic and from research institutes, laboratories, hospitals and other institutions (institutional RAW) which are in compliance with the acceptance criteria. The basic safety requirement of the Repository is to avoid a radioactive release to the environment during its operation and institutional inspection. This commitment is covered by the protection barrier system. The method of solution designed and implemented at the Repository construction complies with the latest knowledge and practice of the repository developments all over the world and meets requirements for the safe radwaste disposal with minimum environmental consequences. All wastes are solidified and have to meet the acceptance criteria before disposal into the Repository. They are processed and treated at the Bohunice RAW Treatment Centre and Liquid RAW Final Treatment Facility at Mochovce. The disposal facility for low level radwastes consists of two double-rows of reinforced concrete vaults with total capacity 7 200 fibre reinforced concrete containers (FCCs) with RAW. One double-row contains 40 The operation of the Repository was started in year 2001 and after ten years, in 2011 was conducted the periodic assessment of nuclear safety with positive results. Till the end of year 2014 was disposed to the Repository 11 514 m 3 RAW. The analysis of total RAW production from operation and decommissioning of all nuclear installation in SR, which has been carried out in frame of the BIDSF project C9.1, has showed that the total volume estimation of conditioned waste is 108 thousand m 3 of which 45.5 % are low level waste (LLW) and 54,5 % very low level waste (VLLW). On the base of this fact there is the need to build 7

  4. HELLE: Health Effects of Low Level Exposures/ Gezondheidseffecten van lage blootstellingniveaus [International workshop: Influence of low level exposures to chemicals and radiation on human and ecological health

    Energy Technology Data Exchange (ETDEWEB)

    Schoten, Eert

    1998-11-26

    The Health Council is closely involved in establishing the scientific foundation of exposure limits for substances and radiation in order to protect public health. Through the years, the Council has contributed to the formulation of principles and procedures, both for carcinogenic and for noncarcinogenic agents. As a rule, the discussion with regard to the derivation of health-based recommended exposure limits centers around the appropriateness of extrapolation methods (What can be inferred from data on high exposure levels and on experimental animals?). Generally speaking, there is a lack of direct information on the health effects of low levels of exposure. Effects at these levels cannot usually be detected by means of traditional animal experiments or epidemiological research. The capacity of these analytical instruments to distinguish between ''signal'' and ''noise'' is inadequate in most cases. Annex B of this report contains a brief outline of the difficulties and the established methods for tackling this problem. In spite of this, the hope exists that the posited weak signals, if they are indeed present, can be detected by other means. The search will have to take place on a deeper level. In other words, effort must be made to discover what occurs at underlying levels of biological organization when organisms are exposed to low doses of radiation or substances. Molecular and cell biology provide various methods and techniques which give an insight into the processes within the cell. This results in an increase in the knowledge about the molecular and cellular effects of exposure to agents, or stated differently, the working mechanisms which form the basis of the health effects. Last year, the Health Council considered that the time was ripe to take stock of the state of knowledge in this field. To this end, an international working conference was held from 19 to 21 October 1997, entitled ''Health Effects of

  5. Landfill disposal of very low level waste

    International Nuclear Information System (INIS)

    Luo Shanggeng

    2009-01-01

    The radioactivities of very low level wastes are very low. VLLW can be disposed by simple and economic burial process. This paper describes the significance of segregation of very low level waste (VLLW), the VLLW-definition and its limit value, and presents an introduction of VLLW-disposing approaches operated world wide. The disposal of VLLW in China is also briefly discussed and suggested here. (author)

  6. Equivalence ratio and constriction effects on RBCC thrust augmentation

    Science.gov (United States)

    Koupriyanov, M.; Etele, J.

    2011-06-01

    A theoretical analysis of a variable area rocket based combined cycle engine with and without simultaneous mixing and combustion is presented. The flowfield is solved using a steady, quasi-one-dimensional, inviscid control volume formulation with combustion effects included via a generalized equilibrium calculation. Compression augmentation is shown to be sensitive to the equivalence ratio within the primary rocket chamber, where ejector section performance is greatest at both low and high equivalence ratios but near a minimum at stoichiometric conditions. The thrust generated by the RBCC engine compared to that generated by the same rocket in isolation can be increased by as much as 12% at constriction ratios of between 45% and 50%. Thrust augmentation is also shown to vary with equivalence ratio, where for a fixed geometry the maximum thrust is generated at equivalence ratios slightly below unity.

  7. Estimating water equivalent snow depth from related meteorological variables

    International Nuclear Information System (INIS)

    Steyaert, L.T.; LeDuc, S.K.; Strommen, N.D.; Nicodemus, M.L.; Guttman, N.B.

    1980-05-01

    Engineering design must take into consideration natural loads and stresses caused by meteorological elements, such as, wind, snow, precipitation and temperature. The purpose of this study was to determine a relationship of water equivalent snow depth measurements to meteorological variables. Several predictor models were evaluated for use in estimating water equivalent values. These models include linear regression, principal component regression, and non-linear regression models. Linear, non-linear and Scandanavian models are used to generate annual water equivalent estimates for approximately 1100 cooperative data stations where predictor variables are available, but which have no water equivalent measurements. These estimates are used to develop probability estimates of snow load for each station. Map analyses for 3 probability levels are presented

  8. Interaction of extremely-low-frequency electromagnetic fields with humans

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1991-07-01

    At a macroscopic level, the effects of extremely low frequency (ELF) electromagnetic fields on humans are well understood based on fundamental physical principles, but far less is known about the nature of the interactions at a cellular or molecular level. Current evidence suggests the effects of ELF on cellular biochemistry are due to interactions with the cell membrane. Elucidation of the mechanism that underlies this transmembrane signaling is critical for a molecular-level understanding of ELF field effects. Further research is also required to clarify a possible link between ELF exposure and increased cancer risk, since estimated ELF exposure in occupational or residential settings is much lower that the levels used in laboratory studies. There is a clear need for additional epidemiological research in which qualitative dosimetry is used to characterize ELF exposure and careful attention is given to possible effects of confounding variables. 24 refs

  9. Is the low level of physical activity a public policy issue?

    Directory of Open Access Journals (Sweden)

    Kalman Michal

    2013-03-01

    Full Text Available BACKGROUND: Many studies and scientific evidence confirm a positive effect of physical activity on the quality of life and human health. Physical activity, which is also one of the key factors preventing mass non-communicable diseases, is decreasing in Europe, including the Czech Republic, both in children and adults. Serious health consequences for the population and economy of the countries are a reason for a discussion about including the low level of physical activity among public policy issues and a higher allocation of public sources into the area of physical activity promotion. OBJECTIVES: The main objective of the paper is to determine whether the low level of physical activity is a public policy issue. An issue that should by systematically addressed by national, regional as well as local policy. METHODS: Through the policy analysis approach we conducted a content analysis of 25 systematically selected foreign national strategies aimed at the issue of physical activity promotion. The data source was an internal database of the World Health Organization - the International Inventory of Documents on Physical Activity Promotion. The content analysis of the strategies was performed using the Atlas.ti software tool. RESULTS: During a content analysis of 25 foreign strategies a total of 411 text segments (quotations relating to the low level of physical activity were selected. These text segments showed five basic features of a public policy issue according to a conceptual framework developed by Bardach (2000 and Patton and Sawicky (1993 - 1 affects the lives of a significant number of people of a society; 2 is analysable; 3 can be solved through public policy tools; 4 the primary cause or problem can be defined; 5 cannot be solved easily and quickly. CONCLUSIONS: The results indicate that the low level of physical activity is a public policy issue that must be systematically addressed at national level.

  10. Effect of Temperature, Pressure and Equivalence Ratio on Ignition Delay in Ignition Quality Tester (IQT): Diesel,n-Heptane, andiso-Octane Fuels under Low Temperature Conditions

    KAUST Repository

    Yang, Seung Yeon; Naser, Nimal; Chung, Suk-Ho; Cha, Junepyo

    2015-01-01

    -octane in relatively low temperature conditions to simulate unsteady spray ignition behavior. A KAUST Research ignition quality tester (KR-IQT) was utilized, which has a feature of varying temperature, pressure and equivalence ratio using a variable displacement fuel

  11. Perfluorinated compounds: Levels, trophic web enrichments and human dietary intakes in transitional water ecosystems

    International Nuclear Information System (INIS)

    Renzi, Monia; Guerranti, Cristiana; Giovani, Andrea; Perra, Guido; Focardi, Silvano E.

    2013-01-01

    Highlights: • PFOA/S levels in a trophic web of a heavily human-stressed lagoon are measured. • High levels were found in mussels, clams and crabs. • The principal PFCs inflow sources for the ecosystem is the river. • Biota (i.e. macroalgae proliferation) contributes to redistribute pollutants in the lagoon. • Human daily dietary intakes are below maximum tolerable levels suggested by the EFSA. -- Abstract: The results of a study on levels of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA), analyzed in terms of HPLC-ESI-MS in water, sediment, macrophyte, bivalve, crustacean and fish samples, are reported here. The aim of the research is to define, for the first time, PFOA/S levels in a heavily human-stressed transitional water ecosystem (Orbetello lagoon, Italy) and evaluate trophic web enrichments and human dietary intakes. The results obtained show that: (i) levels significantly higher than those reported in the literature were found in mussels, clams and crabs; (ii) the river is a significant pollution source; (iii) although absolute levels are relatively low, macroalgae proliferation contributes to redistribute pollutants from river-affected areas throughout the entire lagoon basin; (iv) to the best of our current knowledge, water-filtering species considered in this study are the most exposed to PFOA/S pollution; (v) human daily dietary intakes of PFOA/S through Slow Food-endorsed product consumption are below maximum tolerable levels suggested by the EFSA

  12. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    A method has been devised to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats, and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, some quantitative problems connected with estimating low-dose effects from other disciplines have been reviewed, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to human is discussed

  13. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    We have devised a method to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, researchers have reviewed some quantitative problems connected with estimating low-dose effects from other disciplines, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to humans is discussed

  14. DOE low-level waste long term technology development

    International Nuclear Information System (INIS)

    Barainca, M.J.

    1982-01-01

    The objective of the Department of Energy's Low-Level Waste Management Program is to provide a low-level waste management system by 1986. Areas of concentration are defined as: (1) Waste Generation Reduction Technology, (2) Process and Handling Technology, (3) Environmental Technology, (4) Low-Level Waste Disposal Technology. A program overview is provided with specific examples of technical development. 2 figures

  15. Tissue-equivalent torso phantom for calibration of transuranic-nuclide counting facilities

    International Nuclear Information System (INIS)

    Griffith, R.V.; Anderson, A.L.; Dean, P.N.; Fisher, J.C.; Sundbeck, C.W.

    1986-01-01

    Several tissue-equivalent human-torso phantoms have been constructed for the calibration of counting systems used for in-vivo measurement of transuranic radionuclides. The phantoms contain a simulated human rib cage (in some cases, real bone) and removable model organs, and they include tissue-equivalent chest plates that can be placed over the torso to simulate people with a wide range of statures. The organs included are the lungs, liver, and tracheobronchial lymph nodes. Polyurethane with varying concentrations of added calcium was used to simulate the linear photon-attenuation properties of various human tissues, including lean muscle, adipose-muscle mixtures, cartilage, and bone. Foamed polyurethane was used to simulate lung tissue. Organs have been loaded with highly pure 238 Pu, 239 Pu, 241 Am, and other radionuclides of interest. The validity of the phantom as a calibration standard has been checked in separate intercomparison studies using human subjects whose lungs contained a plutonium simulant. The resulting phantom calibration factors generally compared to within +-20% of the average calibration factors obtained for the human subjects

  16. Packaged low-level waste verification system

    International Nuclear Information System (INIS)

    Tuite, K.T.; Winberg, M.; Flores, A.Y.; Killian, E.W.; McIsaac, C.V.

    1996-01-01

    Currently, states and low-level radioactive waste (LLW) disposal site operators have no method of independently verifying the radionuclide content of packaged LLW that arrive at disposal sites for disposal. At this time, disposal sites rely on LLW generator shipping manifests and accompanying records to insure that LLW received meets the waste acceptance criteria. An independent verification system would provide a method of checking generator LLW characterization methods and help ensure that LLW disposed of at disposal facilities meets requirements. The Mobile Low-Level Waste Verification System (MLLWVS) provides the equipment, software, and methods to enable the independent verification of LLW shipping records to insure that disposal site waste acceptance criteria are being met. The MLLWVS system was developed under a cost share subcontract between WMG, Inc., and Lockheed Martin Idaho Technologies through the Department of Energy's National Low-Level Waste Management Program at the Idaho National Engineering Laboratory (INEL)

  17. Commercial low-level radioactive waste management

    International Nuclear Information System (INIS)

    Coleman, J.A.

    1982-01-01

    The goals, objectives and activities of the Department of Energy's Low-Level Radioactive Waste Management program are reviewed. The goal of the overall Program is to support development of an acceptable, nationwide, near surface waste disposal system by 1986. The commercial LLW program has two major functions: (1) application of the technology improvements for waste handling, treatment and disposal, and (2) assistance to states as they carry out their responsibilities under the Low-Level Radioactive Waste Policy Act of 1980. The priorities for the commercial side of the Low-Level Waste Management Program have been established to meet one goal: to support development of an effective commercial management system by 1986. The first priority is being given to supporting state efforts in forming the institutional structures needed to manage the system. The second priority is the state and industry role in transferring and demonstrating treatment and disposal technologies

  18. National Low-Level Waste Management Program Radionuclide Report Series, Volume 17: Plutonium-239

    International Nuclear Information System (INIS)

    Adams, J.P.; Carboneau, M.L.

    1999-01-01

    This report, Volume 17 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of plutonium-239 (Pu-239). This report also discusses waste types and forms in which Pu-239 can be found, waste and disposal information on Pu-239, and Pu-239 behavior in the environment and in the human body

  19. National Low-Level Waste Management Program Radionuclide Report Series, Volume 17: Plutonium-239

    Energy Technology Data Exchange (ETDEWEB)

    J. P. Adams; M. L. Carboneau

    1999-03-01

    This report, Volume 17 of the National Low-Level Waste Management Program Radionuclide Report Series, discusses the radiological and chemical characteristics of plutonium-239 (Pu-239). This report also discusses waste types and forms in which Pu-239 can be found, waste and disposal information on Pu-239, and Pu-239 behavior in the environment and in the human body.

  20. Interaction between High-Level and Low-Level Image Analysis for Semantic Video Object Extraction

    Directory of Open Access Journals (Sweden)

    Andrea Cavallaro

    2004-06-01

    Full Text Available The task of extracting a semantic video object is split into two subproblems, namely, object segmentation and region segmentation. Object segmentation relies on a priori assumptions, whereas region segmentation is data-driven and can be solved in an automatic manner. These two subproblems are not mutually independent, and they can benefit from interactions with each other. In this paper, a framework for such interaction is formulated. This representation scheme based on region segmentation and semantic segmentation is compatible with the view that image analysis and scene understanding problems can be decomposed into low-level and high-level tasks. Low-level tasks pertain to region-oriented processing, whereas the high-level tasks are closely related to object-level processing. This approach emulates the human visual system: what one “sees” in a scene depends on the scene itself (region segmentation as well as on the cognitive task (semantic segmentation at hand. The higher-level segmentation results in a partition corresponding to semantic video objects. Semantic video objects do not usually have invariant physical properties and the definition depends on the application. Hence, the definition incorporates complex domain-specific knowledge and is not easy to generalize. For the specific implementation used in this paper, motion is used as a clue to semantic information. In this framework, an automatic algorithm is presented for computing the semantic partition based on color change detection. The change detection strategy is designed to be immune to the sensor noise and local illumination variations. The lower-level segmentation identifies the partition corresponding to perceptually uniform regions. These regions are derived by clustering in an N-dimensional feature space, composed of static as well as dynamic image attributes. We propose an interaction mechanism between the semantic and the region partitions which allows to

  1. Oestrogen, ocular function and low-level vision: a review.

    Science.gov (United States)

    Hutchinson, Claire V; Walker, James A; Davidson, Colin

    2014-11-01

    Over the past 10 years, a literature has emerged concerning the sex steroid hormone oestrogen and its role in human vision. Herein, we review evidence that oestrogen (oestradiol) levels may significantly affect ocular function and low-level vision, particularly in older females. In doing so, we have examined a number of vision-related disorders including dry eye, cataract, increased intraocular pressure, glaucoma, age-related macular degeneration and Leber's hereditary optic neuropathy. In each case, we have found oestrogen, or lack thereof, to have a role. We have also included discussion of how oestrogen-related pharmacological treatments for menopause and breast cancer can impact the pathology of the eye and a number of psychophysical aspects of vision. Finally, we have reviewed oestrogen's pharmacology and suggest potential mechanisms underlying its beneficial effects, with particular emphasis on anti-apoptotic and vascular effects. © 2014 Society for Endocrinology.

  2. Responses to the low-level-radiation controversy

    International Nuclear Information System (INIS)

    Bond, V.P.

    1981-01-01

    Some data sets dealing with the hazards of low-level radiation are discussed. It is concluded that none of these reports, individually or collectively, changes appreciably or even significantly the evaluations of possible low-level radiation effects that have been made by several authoritative national and international groups

  3. Equivalent glycemic load (EGL: a method for quantifying the glycemic responses elicited by low carbohydrate foods

    Directory of Open Access Journals (Sweden)

    Spolar Matt

    2006-08-01

    Full Text Available Abstract Background Glycemic load (GL is used to quantify the glycemic impact of high-carbohydrate (CHO foods, but cannot be used for low-CHO foods. Therefore, we evaluated the accuracy of equivalent-glycemic-load (EGL, a measure of the glycemic impact of low-CHO foods defined as the amount of CHO from white-bread (WB with the same glycemic impact as one serving of food. Methods Several randomized, cross-over trials were performed by a contract research organization using overnight-fasted healthy subjects drawn from a pool of 63 recruited from the general population by newspaper advertisement. Incremental blood-glucose response area-under-the-curve (AUC elicited by 0, 5, 10, 20, 35 and 50 g CHO portions of WB (WB-CHO and 3, 5, 10 and 20 g glucose were measured. EGL values of the different doses of glucose and WB and 4 low-CHO foods were determined as: EGL = (F-B/M, where F is AUC after food and B is y-intercept and M slope of the regression of AUC on grams WB-CHO. The dose-response curves of WB and glucose were used to derive an equation to estimate GL from EGL, and the resulting values compared to GL calculated from the glucose dose-response curve. The accuracy of EGL was assessed by comparing the GL (estimated from EGL values of the 4 doses of oral-glucose with the amounts actually consumed. Results Over 0–50 g WB-CHO (n = 10, the dose-response curve was non-linear, but over the range 0–20 g the curve was indistinguishable from linear, with AUC after 0, 5, 10 and 20 g WB-CHO, 10 ± 1, 28 ± 2, 58 ± 5 and 100 ± 6 mmol × min/L, differing significantly from each other (n = 48. The difference between GL values estimated from EGL and those calculated from the dose-response curve was 0 g (95% confidence-interval, ± 0.5 g. The difference between the GL values of the 4 doses of glucose estimated from EGL, and the amounts of glucose actually consumed was 0.2 g (95% confidence-interval, ± 1 g. Conclusion EGL, a measure of the glycemic impact of

  4. Equivalence Testing as a Tool for Fatigue Risk Management in Aviation.

    Science.gov (United States)

    Wu, Lora J; Gander, Philippa H; van den Berg, Margo; Signal, T Leigh

    2018-04-01

    Many civilian aviation regulators favor evidence-based strategies that go beyond hours-of-service approaches for managing fatigue risk. Several countries now allow operations to be flown outside of flight and duty hour limitations, provided airlines demonstrate an alternative method of compliance that yields safety levels "at least equivalent to" the prescriptive regulations. Here we discuss equivalence testing in occupational fatigue risk management. We present suggested ratios/margins of practical equivalence when comparing operations inside and outside of prescriptive regulations for two common aviation safety performance indicators: total in-flight sleep duration and psychomotor vigilance task reaction speed. Suggested levels of practical equivalence, based on expertise coupled with evidence from field and laboratory studies, are ≤ 30 min in-flight sleep and ± 15% of reference response speed. Equivalence testing is illustrated in analyses of a within-subjects field study during an out-and-back long-range trip. During both sectors of their trip, 41 pilots were monitored via actigraphy, sleep diary, and top of descent psychomotor vigilance task. Pilots were assigned to take rest breaks in a standard lie-flat bunk on one sector and in a bunk tapered 9 from hip to foot on the other sector. Total in-flight sleep duration (134 ± 53 vs. 135 ± 55 min) and mean reaction speed at top of descent (3.94 ± 0.58 vs. 3.77 ± 0.58) were equivalent after rest in the full vs. tapered bunk. Equivalence testing is a complimentary statistical approach to difference testing when comparing levels of fatigue and performance in occupational settings and can be applied in transportation policy decision making.Wu LJ, Gander PH, van den Berg M, Signal TL. Equivalence testing as a tool for fatigue risk management in aviation. Aerosp Med Hum Perform. 2018; 89(4):383-388.

  5. Multilevel Optimization Framework for Hierarchical Stiffened Shells Accelerated by Adaptive Equivalent Strategy

    Science.gov (United States)

    Wang, Bo; Tian, Kuo; Zhao, Haixin; Hao, Peng; Zhu, Tianyu; Zhang, Ke; Ma, Yunlong

    2017-06-01

    In order to improve the post-buckling optimization efficiency of hierarchical stiffened shells, a multilevel optimization framework accelerated by adaptive equivalent strategy is presented in this paper. Firstly, the Numerical-based Smeared Stiffener Method (NSSM) for hierarchical stiffened shells is derived by means of the numerical implementation of asymptotic homogenization (NIAH) method. Based on the NSSM, a reasonable adaptive equivalent strategy for hierarchical stiffened shells is developed from the concept of hierarchy reduction. Its core idea is to self-adaptively decide which hierarchy of the structure should be equivalent according to the critical buckling mode rapidly predicted by NSSM. Compared with the detailed model, the high prediction accuracy and efficiency of the proposed model is highlighted. On the basis of this adaptive equivalent model, a multilevel optimization framework is then established by decomposing the complex entire optimization process into major-stiffener-level and minor-stiffener-level sub-optimizations, during which Fixed Point Iteration (FPI) is employed to accelerate convergence. Finally, the illustrative examples of the multilevel framework is carried out to demonstrate its efficiency and effectiveness to search for the global optimum result by contrast with the single-level optimization method. Remarkably, the high efficiency and flexibility of the adaptive equivalent strategy is indicated by compared with the single equivalent strategy.

  6. Different level of population differentiation among human genes.

    Science.gov (United States)

    Wu, Dong-Dong; Zhang, Ya-Ping

    2011-01-14

    During the colonization of the world, after dispersal out of African, modern humans encountered changeable environments and substantial phenotypic variations that involve diverse behaviors, lifestyles and cultures, were generated among the different modern human populations. Here, we study the level of population differentiation among different populations of human genes. Intriguingly, genes involved in osteoblast development were identified as being enriched with higher FST SNPs, a result consistent with the proposed role of the skeletal system in accounting for variation among human populations. Genes involved in the development of hair follicles, where hair is produced, were also found to have higher levels of population differentiation, consistent with hair morphology being a distinctive trait among human populations. Other genes that showed higher levels of population differentiation include those involved in pigmentation, spermatid, nervous system and organ development, and some metabolic pathways, but few involved with the immune system. Disease-related genes demonstrate excessive SNPs with lower levels of population differentiation, probably due to purifying selection. Surprisingly, we find that Mendelian-disease genes appear to have a significant excessive of SNPs with high levels of population differentiation, possibly because the incidence and susceptibility of these diseases show differences among populations. As expected, microRNA regulated genes show lower levels of population differentiation due to purifying selection. Our analysis demonstrates different level of population differentiation among human populations for different gene groups.

  7. Higher-order gravity and the classical equivalence principle

    Science.gov (United States)

    Accioly, Antonio; Herdy, Wallace

    2017-11-01

    As is well known, the deflection of any particle by a gravitational field within the context of Einstein’s general relativity — which is a geometrical theory — is, of course, nondispersive. Nevertheless, as we shall show in this paper, the mentioned result will change totally if the bending is analyzed — at the tree level — in the framework of higher-order gravity. Indeed, to first order, the deflection angle corresponding to the scattering of different quantum particles by the gravitational field mentioned above is not only spin dependent, it is also dispersive (energy-dependent). Consequently, it violates the classical equivalence principle (universality of free fall, or equality of inertial and gravitational masses) which is a nonlocal principle. However, contrary to popular belief, it is in agreement with the weak equivalence principle which is nothing but a statement about purely local effects. It is worthy of note that the weak equivalence principle encompasses the classical equivalence principle locally. We also show that the claim that there exists an incompatibility between quantum mechanics and the weak equivalence principle, is incorrect.

  8. Ratio methods for cost-effective field sampling of commercial radioactive low-level wastes

    International Nuclear Information System (INIS)

    Eberhardt, L.L.; Simmons, M.A.; Thomas, J.M.

    1985-07-01

    In many field studies to determine the quantities of radioactivity at commercial low-level radioactive waste sites, preliminary appraisals are made with field radiation detectors, or other relatively inaccurate devices. More accurate determinations are subsequently made with procedures requiring chemical separations or other expensive analyses. Costs of these laboratory determinations are often large, so that adequate sampling may not be achieved due to budget limitations. In this report, we propose double sampling as a way to combine the expensive and inexpensive aproaches to substantially reduce overall costs. The underlying theory was developed for human and agricultural surveys, and is partially based on assumptions that are not appropriate for commercial low-level waste sites. Consequently, extensive computer simulations were conducted to determine whether the results can be applied in circumstances of importance to the Nuclear Regulatory Commission. This report gives the simulation details, and concludes that the principal equations are appropriate for most studies at commercial low-level waste sites. A few points require further research, using actual commercial low-level radioactive waste site data. The final section of the report provides some guidance (via an example) for the field use of double sampling. Details of the simulation programs are available from the authors. Major findings are listed in the Executive Summary. 9 refs., 9 figs., 30 tabs

  9. Low-Level Radioactive Waste siting simulation information package

    International Nuclear Information System (INIS)

    1985-12-01

    The Department of Energy's National Low-Level Radioactive Waste Management Program has developed a simulation exercise designed to facilitate the process of siting and licensing disposal facilities for low-level radioactive waste. The siting simulation can be conducted at a workshop or conference, can involve 14-70 participants (or more), and requires approximately eight hours to complete. The exercise is available for use by states, regional compacts, or other organizations for use as part of the planning process for low-level waste disposal facilities. This information package describes the development, content, and use of the Low-Level Radioactive Waste Siting Simulation. Information is provided on how to organize a workshop for conducting the simulation. 1 ref., 1 fig

  10. Who regulates the disposal of low-level radioactive waste under the Low-Level Radioactive Waste Policy Act

    International Nuclear Information System (INIS)

    Mostaghel, D.M.

    1988-01-01

    The present existence of immense quantities of low-level nuclear waste, a federal law providing for state or regional control of such waste disposal, and a number of state disposal laws challenged on a variety of constitutional grounds underscore what currently may be the most serious problem in nuclear waste disposal: who is to regulate the disposal of low-level nuclear wastes. This problem's origin may be traced to crucial omissions in the Atomic Energy Act of 1946 and its 1954 amendments (AEA) that concern radioactive waste disposal. Although the AEA states that nuclear materials and facilities are affected with the public interest and should be regulated to provide for the public health and safety, the statute fails to prescribe specific guidelines for any nuclear waste disposal. The Low-Level Radioactive Waste Policy Act of 1980 (LLRWPA) grants states some control over radioactive waste disposal, an area from which they were previously excluded by the doctrine of federal preemption. This Comment discusses the question of who regulates low-level radioactive waste disposal facilities by examining the following: the constitutional doctrines safeguarding federal government authority; area of state authority; grants of specific authority delegations under the LLRWPA and its amendment; and finally, potential problems that may arise depending on whether ultimate regulatory authority is deemed to rest with single states, regional compacts, or the federal government

  11. Low dimensional equivalence of core neutronics model and its application to transient analysis

    International Nuclear Information System (INIS)

    Song Hongbing; Zhao Fuyu

    2015-01-01

    Three-dimensional coupled neutronics thermal-hydraulics reactor analysis is time consuming and occupies huge memory. A one-dimensional model is preferable than the three one in nuclear system analysis, control system design and load following. In this paper, a corewide three dimensional to one dimensional equivalent method has been developed. On the basis of this method 1D axial few groups constants were obtained. The equivalent cross sections were calculated by general spatial homogenization while the transverse buckling was computed through an equivalence based on the 3D flux conservation. Three steady test cases were performed on one dimensional finite difference code ODTAC and the results were compared with TRIVAC-5. The comparison shows that the one dimensional axial power distribution computed by ODTAC correlates well with the three dimensional results calculated by TRIVAC-5. In this study, DRAGON-4 was used to generate the few-group constants of fuel assemblies and the reflector few-group parameters were calculated by WIMS-D4. These collapsed few-group constants were tabulated in a database sorted in ascending order of fuel temperature, coolant temperature and concentration of boric acid. Trilinear interpolation was adopted in cross sections feedback during the transient analysis. In this paper, G1 rod drop accident (RDA) and G1 rod ejection accident (REA) were performed on ODTAC and the computation results were consistent of the physical rules. (author)

  12. Very low level radioactive material

    International Nuclear Information System (INIS)

    Schaller, K.H.; Linsley, G.; Elert, M.

    1993-01-01

    Man's environment contains naturally occurring radionuclides and doses from exposures to these radionuclides mostly cannot be avoided. Consequently, almost everything may be considered as very low level radioactive material. In practical terms, management and the selection of different routes for low level material is confined to material which was subject to industrial processing or which is under a system of radiological control. Natural radionuclides with concentrations reaching reporting or notification levels will be discussed below; nevertheless, the main body of this paper will be devoted to material, mainly of artificial origin, which is in the system involving notification, registration and licensing of practices and sources. It includes material managed in the nuclear sector and sources containing artificially produced radionuclides used in hospitals, and in industry. Radioactive materials emit ionising radiations which are harmful to man and his environment. National and international regulations provide the frame for the system of radiation protection. Nevertheless, concentrations, quantities or types of radionuclide may be such, that the material presents a very low hazard, and may therefore be removed from regulatory control, as it would be a waste of time and effort to continue supervision. These materials are said to be exempted from regulatory control. Material exempted in a particular country is no longer distinguishable from ''ordinary'' material and may be moved from country to country. Unfortunately, criteria for exempting radioactive materials differ strongly between countries and free trade. Therefore there is a necessity for an international approach to be developed for exemption levels

  13. State compacts and low-level waste

    International Nuclear Information System (INIS)

    Brown, H.

    1984-01-01

    In 1979, for the first time, low-level waste (LLW) was brought to the attention of policy makers in most states. For several decades, technical personnel had regulated and managed LLW, but elected officials and their staff had been largely ignorant of the origins and destination of low-level radioactive materials. Events in the fall of 1979 set in motion a sequence of events that has compelled the continuing attention of policy makers in every state in the nation. In December 1979, the Executive Committee of the National Governors' Association appointed an eight-member task force, chaired by Governor Bruce Babbitt of Arizona, to review low-level waste management and to formulate state policy by July 1980. The principal findings were as follows: 1. LLW could be managed most efficiently, both technically and politically, at the state level. 2. Each state should take responsibility for its own waste. 3. The creation of a regional waste management system by means of interstate compacts offered the best promise of creating new disposal capacity. 4. Regions should be allowed to exclude waste generated outside their borders after a specified date

  14. Low-level waste disposal site selection demonstration

    International Nuclear Information System (INIS)

    Rogers, V.C.

    1984-01-01

    This paper discusses the results of recent studies undertaken at EPRI related to low-level waste disposal technology. The initial work provided an overview of the state of the art including an assessment of its influence upon transportation costs and waste form requirements. The paper discusses work done on the overall system design aspects and computer modeling of disposal site performance characteristics. The results of this analysis are presented and provide a relative ranking of the importance of disposal parameters. This allows trade-off evaluations to be made of factors important in the design of a shallow land burial facility. To help minimize the impact of a shortage of low-level radioactive waste disposal sites, EPRI is closely observing the development of bellweather projects for developing new sites. The purpose of this activity is to provide information about lessons learned in those projects in order to expedite the development of additional disposal facilities. This paper describes most of the major stems in selecting a low-level radioactive waste disposal site in Texas. It shows how the Texas Low-Level Radioactive Waste Disposal Authority started with a wide range of potential siting areas in Texas and narrowed its attention down to a few preferred sites. The parameters used to discriminate between large areas of Texas and, eventually, 50 candidate disposal sites are described, along with the steps in the process. The Texas process is compared to those described in DOE and EPRI handbooks on site selection and to pertinent NRC requirements. The paper also describes how an inventory of low-level waste specific to Texas was developed and applied in preliminary performance assessments of two candidate sites. Finally, generic closure requirements and closure operations for low-level waste facilities in arid regions are given

  15. Shallow ground burial of low-level waste

    International Nuclear Information System (INIS)

    Camilleri, A.; Cooper, M.B.; Hargrave, N.J.; Munslow-Davies, L.

    1989-01-01

    Acceptance criteria for the disposal of low-level radioactive wastes are presented for adoption throughout Australia, a continent in which there are readily available areas in arid, sparsely inhabited places, likely to be suitable as sites for shallow ground burial. Drawing upon overseas practices and experiences, criteria have been developed for low-level waste disposal and are intended to be applicable and relevant to the Australian situation. Concentration levels have been derived for a shallow ground burial facility assuming a realistic institutional control period of 200 years. A comparison is made between this period and institutional control for 100 years and 300 years. Longer institutional control periods enable the acceptance of higher concentrations of radionuclides of intermediate half-lives. Scenarios, which have been considered, include current Australian pastoral practices and traditional Aboriginal occupancy. The derived radionuclide concentration levels for the disposal of low level wastes are not dissimilar to those developed in other countries. 17 refs., 6 tabs., 1 fig

  16. Estimation of thyroid equivalent doses during evacuation based on body surface contamination levels in the nuclear accident of FDNPS in 2011

    Science.gov (United States)

    Ohba, Takashi; Hasegawa, Arifumi; Kohayakawa, Yoshitaka; Kondo, Hisayoshi; Suzuki, Gen

    2017-09-01

    To reduce uncertainty in thyroid dose estimation, residents' radiation protection behavior should be reflected in the estimation. Screening data of body surface contamination provide information on exposure levels during evacuation. Our purpose is to estimate thyroid equivalent doses based on body surface contamination levels using a new methodology. We obtained a record of 7,539 residents/evacuees. Geiger-Mueller survey meter measurement value in cpm was translated into Bq/cm2 according to the nuclides densities obtained by measuring clothing from two persons by germanium γ-spectrometer. The measurement value of body surface contamination on head was adjusted by a natural removal rate of 15 hours and radionuclides' physical half-life. Thyroid equivalent dose of 1-year-old children by inhalation was estimated by two-dimensional Monte Carlo simulation. The proportions of evacuees/residents with measurement value in cpm of Namie and Minamisoma groups were higher than those of other groups during both periods (p<0.01, Kruskal-Wallis). During 12-14 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were estimated as 2.7 and 86.0 mSv, respectively, for Namie group, and 4.2 and 17.2 mSv, respectively, for Minamisoma group, 0.1 and 1.0 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 0.2 and 2.1 mSv, respectively, for the other group. During 15- 17 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were 0.8 and 15.7 mSv, respectively, for Namie group, and 1.6 and 8.4 mSv, respectively, for Minamisoma group, 0.2 and 13.2 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 1.2 and 12.7 mSv, respectively, for the other group. It was indicated that inhalation dose was generally higher in Namie and Minamisoma groups during 12-14 March than those during 15-17 March might reflect different self-protective behavior to radioactive plumes from other groups.

  17. Management of very low-level radioactive waste

    International Nuclear Information System (INIS)

    Chapalain, E.; Damoy, J.; Joly, J.M.

    2003-01-01

    This document comprises 3 articles. The first article presents the concern of very low-level radioactive wastes generated in nuclear installations, the second article describes the management of the wastes issued from the dismantling operations of the ALS (linear accelerator of Saclay) and of the Saturn synchrotron both located in Saclay Cea's center. The last article presents the storage facility which is specifically dedicated to very low-level radioactive wastes. This storage facility, which is located at Morvilliers, near the 'Centre de l Aube' (used to store the low-, and medium-level, short-lived radioactive wastes), will receive the first packages next summer. Like the other storage facilities, it will be managed by ANDRA (national radioactive waste management agency)

  18. Controlling human corneal stromal stem cell contraction to mediate rapid cell and matrix organization of real architecture for 3-dimensional tissue equivalents.

    Science.gov (United States)

    Mukhey, Dev; Phillips, James B; Daniels, Julie T; Kureshi, Alvena K

    2018-02-01

    The architecture of the human corneal stroma consists of a highly organized extracellular matrix (ECM) interspersed with keratocytes. Their progenitor cells; corneal stromal stem cells (CSSC) are located at the periphery, in the limbal stroma. A highly organized corneal ECM is critical for effective transmission of light but this structure may be compromised during injury or disease, resulting in loss of vision. Re-creating normal organization in engineered tissue equivalents for transplantation often involves lengthy culture times that are inappropriate for clinical use or utilisation of synthetic substrates that bring complications such as corneal melting. CSSC have great therapeutic potential owing to their ability to reorganize a disorganized matrix, restoring transparency in scarred corneas. We examined CSSC contractile behavior to assess whether this property could be exploited to rapidly generate cell and ECM organization in Real Architecture For 3D Tissues (RAFT) tissue equivalents (TE) for transplantation. Free-floating collagen gels were characterized to assess contractile behavior of CSSC and establish optimum cell density and culture times. To mediate cell and collagen organization, tethered collagen gels seeded with CSSC were cultured and subsequently stabilized with the RAFT process. We demonstrated rapid creation of biomimetic RAFT TE with tunable structural properties. These displayed three distinct regions of varying degrees of cellular and collagen organization. Interestingly, increased organization coincided with a dramatic loss of PAX6 expression in CSSC, indicating rapid differentiation into keratocytes. The organized RAFT TE system could be a useful bioengineering tool to rapidly create an organized ECM while simultaneously controlling cell phenotype. For the first time, we have demonstrated that human CSSC exhibit the phenomenon of cellular self-alignment in tethered collagen gels. We found this mediated rapid co-alignment of collagen fibrils

  19. A Study on intelligent measurement of nuclear explosion equivalent in atmosphere

    International Nuclear Information System (INIS)

    Wang Desheng; Wu Xiaohong

    1999-01-01

    Measurement of nuclear explosion equivalent in atmosphere is an important subject for nuclear survey. Based on the relations between nuclear explosion equivalent and the minimum illuminance time of light radiation from nuclear explosion. The method of RC differential valley time detection and mean-time taking is presented the method, using a single-chip computer as a intelligent part, can realize intelligent measurement of minimum illuminance time with high reliability and low power consumption. This method provides a practical mean for quick, accurate and reliable measurement of nuclear explosion equivalent in atmosphere

  20. Different level of population differentiation among human genes

    Directory of Open Access Journals (Sweden)

    Zhang Ya-Ping

    2011-01-01

    Full Text Available Abstract Background During the colonization of the world, after dispersal out of African, modern humans encountered changeable environments and substantial phenotypic variations that involve diverse behaviors, lifestyles and cultures, were generated among the different modern human populations. Results Here, we study the level of population differentiation among different populations of human genes. Intriguingly, genes involved in osteoblast development were identified as being enriched with higher FST SNPs, a result consistent with the proposed role of the skeletal system in accounting for variation among human populations. Genes involved in the development of hair follicles, where hair is produced, were also found to have higher levels of population differentiation, consistent with hair morphology being a distinctive trait among human populations. Other genes that showed higher levels of population differentiation include those involved in pigmentation, spermatid, nervous system and organ development, and some metabolic pathways, but few involved with the immune system. Disease-related genes demonstrate excessive SNPs with lower levels of population differentiation, probably due to purifying selection. Surprisingly, we find that Mendelian-disease genes appear to have a significant excessive of SNPs with high levels of population differentiation, possibly because the incidence and susceptibility of these diseases show differences among populations. As expected, microRNA regulated genes show lower levels of population differentiation due to purifying selection. Conclusion Our analysis demonstrates different level of population differentiation among human populations for different gene groups.

  1. Characterization of DNA polymerase. beta. mRNA: cell-cycle growth response in cultured human cells

    Energy Technology Data Exchange (ETDEWEB)

    Zmudzka, B Z; Fornace, A; Collins, J; Wilson, S H

    1988-10-25

    DNA polymerase ..beta.. (..beta..-polymerase) is a housekeeping enzyme involved in DNA repair in vertebrate cells. The authors used a cDNA probe to study abundance of ..beta..-polymerase mRNA in cultured human cells. The mRNA level in synchronized HeLa cells, representing different stages of the cell-cycle, varied only slightly. Contact inhibited fibroblasts AG-1522 contained the same level of mRNA as growing cells. The steady-state level of mRNA in fibroblasts is equivalent to 6 molecules per cell. The results indicate that the ..beta..-polymerase transcript is low abundance and is neither cell-cycles nor growth phase responsive.

  2. BEIR-III report and the health effects of low-level radiation

    International Nuclear Information System (INIS)

    Fabrikant, J.I.

    1980-01-01

    The present BEIR-III Committee has not highlighted any controversy over the health effects of low-level radiation. In its evaluation of the experimental data and epidemiological surveys, the Committee has carefully reviewed and assessed the value of all the available scientific evidence for estimating numerical risk coefficients for the health hazards to human populations exposed to low levels of ionizing radiation. Responsible public awareness of the possible health effects of ionizing radiations from medical and industrial radiation exposure, centers on three important matters of societal concern: (1) to place into perspective the extent of harm to the health of man and his descendants to be expected in the present and in the future from those societal activities involving ionizing radiation; (2) to develop quantitative indices of harm based on dose-effect relationships; such indices could then be used with prudent caution to introduce concepts of the regulation of population doses on the basis of somatic and genetic risks; and (3) to identify the magnitude and extent of radiation activities which could cause harm, to assess their relative significance, and to provide a framework for recommendations on how to reduce unnecessary radiation exposure to human populations. The main difference of the BEIR Committee Report is not so much from new data or new interpretations of existing data, but rather from a philosophical approach and appraisal of existing and future radiation protection resulting from an atmosphere of constantly changing societal conditions and public attitudes

  3. Visual perception as retrospective Bayesian decoding from high- to low-level features.

    Science.gov (United States)

    Ding, Stephanie; Cueva, Christopher J; Tsodyks, Misha; Qian, Ning

    2017-10-24

    When a stimulus is presented, its encoding is known to progress from low- to high-level features. How these features are decoded to produce perception is less clear, and most models assume that decoding follows the same low- to high-level hierarchy of encoding. There are also theories arguing for global precedence, reversed hierarchy, or bidirectional processing, but they are descriptive without quantitative comparison with human perception. Moreover, observers often inspect different parts of a scene sequentially to form overall perception, suggesting that perceptual decoding requires working memory, yet few models consider how working-memory properties may affect decoding hierarchy. We probed decoding hierarchy by comparing absolute judgments of single orientations and relative/ordinal judgments between two sequentially presented orientations. We found that lower-level, absolute judgments failed to account for higher-level, relative/ordinal judgments. However, when ordinal judgment was used to retrospectively decode memory representations of absolute orientations, striking aspects of absolute judgments, including the correlation and forward/backward aftereffects between two reported orientations in a trial, were explained. We propose that the brain prioritizes decoding of higher-level features because they are more behaviorally relevant, and more invariant and categorical, and thus easier to specify and maintain in noisy working memory, and that more reliable higher-level decoding constrains less reliable lower-level decoding. Published under the PNAS license.

  4. Low-level radioactive waste management technology development

    International Nuclear Information System (INIS)

    Coleman, J.A.

    1985-01-01

    Although reviews of disposal practices and site performance indicated that there were no releases to the environment that would affect public health and safety, it became clear that: (a) several burial grounds were not performing as expected; (b) long-term maintenance of closed trenches could be a costly problem, and (c) more cost-effective methods could be developed for the treatment, packing, and disposal of low-level waste. As a result of these reviews, the Department of Energy developed the Low-level Waste Management Program to seek improvements in existing practices, correct obvious deficiencies, and develop site closure techniques that would avoid expensive long-term maintenance and monitoring. Such technology developments provide a better understanding of the physical and technical mechanisms governing low-level waste treatment and disposal and lead to improvement in the performance of disposal sites. The primary means of disposal of low-level waste has been the accepted and regulated practice of shallow land disposal, i.e., placement of low-level waste in trenches 5 to 10 meters deep with several meters of special soil cover. Department of Energy waste is primarily disposed at six major shallow land disposal sites. Commercial waste is currently disposed of at three major sites in the nation - Barnwell, South Carolina; Richland, Washington; and Beatty, Nevada. In the late 1970's public concern arose regarding the management practices of sites operated by the civilian sector and by the Department of Energy

  5. Low-Dose Irradiation Enhances Gene Targeting in Human Pluripotent Stem Cells.

    Science.gov (United States)

    Hatada, Seigo; Subramanian, Aparna; Mandefro, Berhan; Ren, Songyang; Kim, Ho Won; Tang, Jie; Funari, Vincent; Baloh, Robert H; Sareen, Dhruv; Arumugaswami, Vaithilingaraja; Svendsen, Clive N

    2015-09-01

    Human pluripotent stem cells (hPSCs) are now being used for both disease modeling and cell therapy; however, efficient homologous recombination (HR) is often crucial to develop isogenic control or reporter lines. We showed that limited low-dose irradiation (LDI) using either γ-ray or x-ray exposure (0.4 Gy) significantly enhanced HR frequency, possibly through induction of DNA repair/recombination machinery including ataxia-telangiectasia mutated, histone H2A.X and RAD51 proteins. LDI could also increase HR efficiency by more than 30-fold when combined with the targeting tools zinc finger nucleases, transcription activator-like effector nucleases, and clustered regularly interspaced short palindromic repeats. Whole-exome sequencing confirmed that the LDI administered to hPSCs did not induce gross genomic alterations or affect cellular viability. Irradiated and targeted lines were karyotypically normal and made all differentiated lineages that continued to express green fluorescent protein targeted at the AAVS1 locus. This simple method allows higher throughput of new, targeted hPSC lines that are crucial to expand the use of disease modeling and to develop novel avenues of cell therapy. The simple and relevant technique described in this report uses a low level of radiation to increase desired gene modifications in human pluripotent stem cells by an order of magnitude. This higher efficiency permits greater throughput with reduced time and cost. The low level of radiation also greatly increased the recombination frequency when combined with developed engineered nucleases. Critically, the radiation did not lead to increases in DNA mutations or to reductions in overall cellular viability. This novel technique enables not only the rapid production of disease models using human stem cells but also the possibility of treating genetically based diseases by correcting patient-derived cells. ©AlphaMed Press.

  6. Monte Carlo simulations of the secondary neutron ambient and effective dose equivalent rates from surface to suborbital altitudes and low Earth orbit.

    Science.gov (United States)

    El-Jaby, Samy; Richardson, Richard B

    2015-07-01

    Occupational exposures from ionizing radiation are currently regulated for airline travel (Earth orbit (∼300-400 km). Aircrew typically receive between 1 and 6 mSv of occupational dose annually, while aboard the International Space Station, the area radiation dose equivalent measured over just 168 days was 106 mSv at solar minimum conditions. It is anticipated that space tourism vehicles will reach suborbital altitudes of approximately 100 km and, therefore, the annual occupational dose to flight crew during repeated transits is expected to fall somewhere between those observed for aircrew and astronauts. Unfortunately, measurements of the radiation environment at the high altitudes reached by suborbital vehicles are sparse, and modelling efforts have been similarly limited. In this paper, preliminary MCNPX radiation transport code simulations are developed of the secondary neutron flux profile in air from surface altitudes up to low Earth orbit at solar minimum conditions and excluding the effects of spacecraft shielding. These secondary neutrons are produced by galactic cosmic radiation interacting with Earth's atmosphere and are among the sources of radiation that can pose a health risk. Associated estimates of the operational neutron ambient dose equivalent, used for radiation protection purposes, and the neutron effective dose equivalent that is typically used for estimates of stochastic health risks, are provided in air. Simulations show that the neutron radiation dose rates received at suborbital altitudes are comparable to those experienced by aircrew flying at 7 to 14 km. We also show that the total neutron dose rate tails off beyond the Pfotzer maximum on ascension from surface up to low Earth orbit. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  7. ASSESSMENT OF RADIOACTIVE AND NON-RADIOACTIVE CONTAMINANTS FOUND IN LOW LEVEL RADIOACTIVE WASTE STREAMS

    International Nuclear Information System (INIS)

    R.H. Little, P.R. Maul, J.S.S. Penfoldag

    2003-01-01

    This paper describes and presents the findings from two studies undertaken for the European Commission to assess the long-term impact upon the environment and human health of non-radioactive contaminants found in various low level radioactive waste streams. The initial study investigated the application of safety assessment approaches developed for radioactive contaminants to the assessment of nonradioactive contaminants in low level radioactive waste. It demonstrated how disposal limits could be derived for a range of non-radioactive contaminants and generic disposal facilities. The follow-up study used the same approach but undertook more detailed, disposal system specific calculations, assessing the impacts of both the non-radioactive and radioactive contaminants. The calculations undertaken indicated that it is prudent to consider non-radioactive, as well as radioactive contaminants, when assessing the impacts of low level radioactive waste disposal. For some waste streams with relatively low concentrations of radionuclides, the potential post-closure disposal impacts from non-radioactive contaminants can be comparable with the potential radiological impacts. For such waste streams there is therefore an added incentive to explore options for recycling the materials involved wherever possible

  8. Cancer risk assessment of polycyclic aromatic hydrocarbon contaminated soils determined using bioassay-derived levels of benzo[a]pyrene equivalents.

    Science.gov (United States)

    Lemieux, Christine L; Long, Alexandra S; Lambert, Iain B; Lundstedt, Staffan; Tysklind, Mats; White, Paul A

    2015-02-03

    Here we evaluate the excess lifetime cancer risk (ELCR) posed by 10 PAH-contaminated soils using (i) the currently advocated, targeted chemical-specific approach that assumes dose additivity for carcinogenic PAHs and (ii) a bioassay-based approach that employs the in vitro mutagenic activity of the soil fractions to determine levels of benzo[a]pyrene equivalents and, by extension, ELCR. Mutagenic activity results are presented in our companion paper.1 The results show that ELCR values for the PAH-containing fractions, determined using the chemical-specific approach, are generally (i.e., 8 out of 10) greater than those calculated using the bioassay-based approach; most are less than 5-fold greater. Only two chemical-specific ELCR estimates are less than their corresponding bioassay-derived values; differences are less than 10%. The bioassay-based approach, which permits estimation of ELCR without a priori knowledge of mixture composition, proved to be a useful tool to evaluate the chemical-specific approach. The results suggest that ELCR estimates for complex PAH mixtures determined using a targeted, chemical-specific approach are reasonable, albeit conservative. Calculated risk estimates still depend on contentious PEFs and cancer slope factors. Follow-up in vivo mutagenicity assessments will be required to validate the results and their relevance for human health risk assessment of PAH-contaminated soils.

  9. Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests.

    Science.gov (United States)

    Zahouani, H; Pailler-Mattei, C; Sohm, B; Vargiolu, R; Cenizo, V; Debret, R

    2009-02-01

    The study of changes in skin structure with age is becoming all the more important with the increase in life. The atrophy that occurs during aging is accompanied by more profound changes, with a loss of organization within the elastic collagen network and alterations in the basal elements. The aim of this study is to present a method to determine the mechanical properties of total human skin in vivo compared with dermal equivalents (DEs) using indentation and static friction tests. A new bio-tribometer working at a low contact pressure for the characterization the mechanical properties of the skin has been developed. This device, based on indentation and static friction tests, also allows to characterize the skin in vivo and reconstructed DEs in a wide range of light contact forces, stress and strain. This original bio-tribometer shows the ability to assess the skin elasticity and friction force in a wide range of light normal load (0.5-2 g) and low contact pressure (0.5-2 kPa). The results obtained by this approach show identical values of the Young's modulus E(*) and the shear modulus G(*) of six DEs obtained from a 62-year-old subject (E(*)=8.5+/-1.74 kPa and G(*)=3.3+/-0.46 kPa) and in vivo total skin of 20 subjects aged 55 to 70 years (E(*)=8.3+/-2.1 kPa, G(*)=2.8+/-0.8 kpa).

  10. Leaching studies of low-level radioactive waste forms

    International Nuclear Information System (INIS)

    Dayal, R.; Arora, H.; Milian, L.; Clinton, J.

    1985-01-01

    A research program has been underway at the Brookhaven National Laboratory to investigate the release of radionuclides from low-level waste forms under laboratory conditions. This paper describes the leaching behavior of Cs-137 from two major low-level waste streams, that is, ion exchange bead resin and boric acid concentrate, solidified in Portland cement. The resultant leach data are employed to evaluate and predict the release behavior of Cs-137 from low-level waste forms under field burial conditions

  11. Human reliability analysis approach to level 1 PSA - shutdown and low power operation of Mochovce NPP, Unit 1, Slovakia

    International Nuclear Information System (INIS)

    Stojka, Tibor; Holy, Jaroslav

    2003-01-01

    The paper presents general approach, used methods and form of documentation of the results as have been applied within the Human Reliability Analysis (HRA) task of the shutdown and low power PSA (SPSA) study for Mochovce nuclear power plant, Unit 1, Slovakia. The paper describes main goals of the HRA task within the SPSA project, applied methods and data sources. Basic steps of the HRA task and human errors (HE) classification are also specified in its first part. The main part of the paper deals with pre-initiator human errors, human-induced initiators and response to initiator human errors. Since the expert judgment method (SLIM) was used for the last type of human errors probability assessment, also related activities are described including preparation works (performance shaping factors (PSFs) selection, development of PSF classification tables, preparation of aid tools for interview with plant experts), qualitative analysis (sources of information and basic steps) and quantitative analysis itself (human errors classification for final quantification including criteria used for the classification, description of structure of the spreadsheet used for quantification and treatment with dependencies). The last part of the paper describes form of documentation of the final results and provides some findings. (author)

  12. Vitrification of low-level and mixed wastes

    International Nuclear Information System (INIS)

    Johnson, T.R.; Bates, J.K.; Feng, Xiangdong.

    1994-01-01

    The US Department of Energy (DOE) and nuclear utilities have large quantities of low-level and mixed wastes that must be treated to meet repository performance requirements, which are likely to become even more stringent. The DOE is developing cost-effective vitrification methods for producing durable waste forms. However, vitrification processes for high-level wastes are not applicable to commercial low-level wastes containing large quantities of metals and small amounts of fluxes. New vitrified waste formulations are needed that are durable when buried in surface repositories

  13. Radiation and man - evaluation of biological and environmental low level radiation effects

    International Nuclear Information System (INIS)

    Riklis, E.

    1977-01-01

    The harmful effects of acute radiation cannot be resolved by statistical means and require clearer knowledge of mechanisms of action and much wider collection of human experience before any definite sound stand can be taken. Much information has accumulated from animal experiments, and still the interpretations are not always clearcut, but for human experience it is only the occasional accident which can give a direct answer. Some of the phenomena attributed to low dose radiation are summarized. There are regions of radiation exposure about which we have only limited positive knowledge, an all low-dose risk estimates have been based on effects observed at relatively high doses. Much information has been gathered which does not support the severity of former basic principles, especially our knowledge of mechanisms of repair existing in most cells as natural defence against the damages caused by radiation as well as by many chemicals which act as mutagenic and carcinogenic agents. Understanding these mechanism, their scope of action and their availability to a damaged cell and organism will lead towards modification of the acceptable permissible exposures, in some cases towards severity, but in most cases towards leniency and higher values. For the evaluation of the effects of low level low dose-rate radiations, whether external, or from internal deposition of isotopes, only late somatic and genetic effects should be considered. (B.G.)

  14. Overexpression of human and fly frataxins in Drosophila provokes deleterious effects at biochemical, physiological and developmental levels.

    Directory of Open Access Journals (Sweden)

    Juan A Navarro

    Full Text Available BACKGROUND: Friedreich's ataxia (FA, the most frequent form of inherited ataxias in the Caucasian population, is caused by a reduced expression of frataxin, a highly conserved protein. Model organisms have contributed greatly in the efforts to decipher the function of frataxin; however, the precise function of this protein remains elusive. Overexpression studies are a useful approach to investigate the mechanistic actions of frataxin; however, the existing literature reports contradictory results. To further investigate the effect of frataxin overexpression, we analyzed the consequences of overexpressing human (FXN and fly (FH frataxins in Drosophila. METHODOLOGY/PRINCIPAL FINDINGS: We obtained transgenic flies that overexpressed human or fly frataxins in a general pattern and in different tissues using the UAS-GAL4 system. For both frataxins, we observed deleterious effects at the biochemical, histological and behavioral levels. Oxidative stress is a relevant factor in the frataxin overexpression phenotypes. Systemic frataxin overexpression reduces Drosophila viability and impairs the normal embryonic development of muscle and the peripheral nervous system. A reduction in the level of aconitase activity and a decrease in the level of NDUF3 were also observed in the transgenic flies that overexpressed frataxin. Frataxin overexpression in the nervous system reduces life span, impairs locomotor ability and causes brain degeneration. Frataxin aggregation and a misfolding of this protein have been shown not to be the mechanism that is responsible for the phenotypes that have been observed. Nevertheless, the expression of human frataxin rescues the aconitase activity in the fh knockdown mutant. CONCLUSION/SIGNIFICANCE: Our results provide in vivo evidence of a functional equivalence for human and fly frataxins and indicate that the control of frataxin expression is important for treatments that aim to increase frataxin levels.

  15. The equivalence principle and the gravitational constant in experimental relativity

    International Nuclear Information System (INIS)

    Spallicci, A.D.A.M.

    1988-01-01

    Fischbach's analysis of the Eotvos experiment, showing an embedded fifth force, has stressed the importance of further tests of the Equivalence Principle (EP). From Galilei and Newton, the EP played the role of a postulate for all gravitational physics and mechanics (weak EP), until Einstein, who extended the validity of the EP to all physics (strong EP). After Fischbach's publication on the fifth force, several experiments have been performed or simply proposed to test the WEP. They are concerned with possible gravitational potential anomalies, depending upon distances or matter composition. While the low level of accuracy with which the gravitational constant G is known has been recognized, experiments have been proposed to test G in the range from few cm until 200 m. This paper highlights the different features of the proposed space experiments. Possible implications on the metric formalism for objects in low potential and slow motion are briefly indicated

  16. Construing Morality at High versus Low Levels Induces Better Self-control, Leading to Moral Acts

    Directory of Open Access Journals (Sweden)

    Chia-Chun Wu

    2017-06-01

    Full Text Available Human morality entails a typical self-control dilemma in which one must conform to moral rules or socially desirable norms while exerting control over amoral, selfish impulses. Extant research regarding the connection between self-control and level of construal suggest that, compared with a low-level, concrete construal (highlighting means and resources, e.g., answering ‘how’ questions, a high-level, abstract construal (highlighting central goals, e.g., answering ‘why’ questions promotes self-control. Hence, construing morality at higher levels rather than lower levels should engender greater self-control and, it follows, promote a tendency to perform moral acts. We conducted two experiments to show that answering “why” (high-level construal vs. “how” (low-level construal questions regarding morality was associated with a situational state of greater self-control, as indexed by less Stroop interference in the Stroop color-naming task (Experiments 1 and 2. Participants exposed to “why” questions regarding morality displayed a greater inclination for volunteerism (Experiment 1, showed a lower tendency toward selfishness in a dictator game (Experiment 2, and were more likely to return undeserved money (Experiment 2 compared with participants exposed to “how” questions regarding morality. In both experiments, self-control mediated the effect of a high-level construal of morality on dependent measures. The current research constitutes a new approach to promoting prosociality and moral education. Reminding people to think abstractly about human morality may help them to generate better control over the temptation to benefit from unethical acts and make it more likely that they will act morally.

  17. Construing Morality at High versus Low Levels Induces Better Self-control, Leading to Moral Acts.

    Science.gov (United States)

    Wu, Chia-Chun; Wu, Wen-Hsiung; Chiou, Wen-Bin

    2017-01-01

    Human morality entails a typical self-control dilemma in which one must conform to moral rules or socially desirable norms while exerting control over amoral, selfish impulses. Extant research regarding the connection between self-control and level of construal suggest that, compared with a low-level, concrete construal (highlighting means and resources, e.g., answering 'how' questions), a high-level, abstract construal (highlighting central goals, e.g., answering 'why' questions) promotes self-control. Hence, construing morality at higher levels rather than lower levels should engender greater self-control and, it follows, promote a tendency to perform moral acts. We conducted two experiments to show that answering "why" (high-level construal) vs. "how" (low-level construal) questions regarding morality was associated with a situational state of greater self-control, as indexed by less Stroop interference in the Stroop color-naming task (Experiments 1 and 2). Participants exposed to "why" questions regarding morality displayed a greater inclination for volunteerism (Experiment 1), showed a lower tendency toward selfishness in a dictator game (Experiment 2), and were more likely to return undeserved money (Experiment 2) compared with participants exposed to "how" questions regarding morality. In both experiments, self-control mediated the effect of a high-level construal of morality on dependent measures. The current research constitutes a new approach to promoting prosociality and moral education. Reminding people to think abstractly about human morality may help them to generate better control over the temptation to benefit from unethical acts and make it more likely that they will act morally.

  18. ORION: a computer code for evaluating environmental concentrations and dose equivalent to human organs or tissue from airborne radionuclides

    International Nuclear Information System (INIS)

    Shinohara, K.; Nomura, T.; Iwai, M.

    1983-05-01

    The computer code ORION has been developed to evaluate the environmental concentrations and the dose equivalent to human organs or tissue from air-borne radionuclides released from multiple nuclear installations. The modified Gaussian plume model is applied to calculate the dispersion of the radionuclide. Gravitational settling, dry deposition, precipitation scavenging and radioactive decay are considered to be the causes of depletion and deposition on the ground or on vegetation. ORION is written in the FORTRAN IV language and can be run on IBM 360, 370, 303X, 43XX and FACOM M-series computers. 8 references, 6 tables

  19. Microbiological treatment of low level radioactive waste

    International Nuclear Information System (INIS)

    Ashley, N.V.; Pugh, S.Y.R.; Banks, C.J.; Humphreys, P.N.

    1992-01-01

    This report summarises the work of an experimental programme investigating the anaerobic digestion of low-level radioactive wastes. The project focused on the selection of the optimum bioreactor design to achieve 95% removal or stabilisation of the biodegradable portion of low-level radioactive wastes. Performance data was obtained for the bioreactors and process scale-up factors for the construction of a full-scale reactor were considered. (author)

  20. Managing low-level radioactive waste in Massachusetts. Final report

    International Nuclear Information System (INIS)

    Bander, S.R.; Goldstein, M.E.

    1983-12-01

    As one of the country's largest generators of low-level radioactive waste, Massachusetts has begun independently seeking solutions to the questions surrounding low-level waste management issues. The Massachusetts Department of Public Health, Radiation Control Program, obtained funding from the U.S. Department ofEnergy through EG and G, Idaho, Inc. to develop a low-level waste management strategy for the Commonwealth. The Working Group was made up of individuals from various waste generating industries, environmental and public interest groups, medical and academic institutions, and affected state agencies. This final report document contains the following staff project reports: Proposed Low-Level Radioactive Waste Management Plan for The Commonwealth of Massachusetts, February 1983 and Low-Level Radioactive Waste Management in Massachusetts - Actions to be Considered for Implementation in 1984-1986, December 1983. These two staff reports represent the completion of the Massachusetts Low-Level Radioactive Waste Management Project. The first report provides some of the background material to the issues and some of the alternative courses of action which can be considered by state policy-makers. The second report provides the next phase in the process by delineating specific steps which may be taken before 1986 in order to address the low-level waste problem, and the estimated amount of time needed to complete each step

  1. Low-level radioactive waste management

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, T [Radioactive Waste Management Center, Tokyo (Japan)

    1980-08-01

    In the development and utilization of nuclear energy, variety of radioactive wastes arise. A largest part is low level radioactive wastes. In Japan, they are concentrated and solidified, and stored in drums. However, no low level wastes have yet been finally disposed of; there are now about 260,000 drums of such wastes stored on the sites. In Japan, the land is narrow, and its structure is geologically unstable, so that the sea disposal is sought. On the other hand, the development of technology for the ground disposal has lagged behind the sea disposal until recently because of the law concerned. The following matters are described: for the sea disposal, preparatory technology studies, environment safety assessment, administrative measures, and international control; for the ground disposal, experiments, surveys, disposal site selection, and the concept of island repositories.

  2. Inhibition of fungal growth with extreme low oxygen levels

    DEFF Research Database (Denmark)

    Nielsen, Per Væggemose; Haasum, Iben

    1998-01-01

    Fungal spoilage of foods is effectively controlled by removal of oxygen from the package, especially if this is combined with elevated carbon dioxide (CO2) levels. However, great uncertainty exist on just how low the residual oxygen levels in the package must be especially when carbon dioxide lev...... food with low CO2 levels. Active packaging with oxygen absorbers may be considered for these products. The packaging solution must also reflect the micro flora of the product.......Fungal spoilage of foods is effectively controlled by removal of oxygen from the package, especially if this is combined with elevated carbon dioxide (CO2) levels. However, great uncertainty exist on just how low the residual oxygen levels in the package must be especially when carbon dioxide...... Penicillia and Aspergilli were also inhibited by oxygen levels less than 0.5%, but less than 0.01% was required to efficiently inhibit these fungi. Most resistant to very low oxygen levels was the Fusarium species.These results shows that very low oxygen levels are required to avoid fungal growth in package...

  3. Low level radiation: how low can you get?

    International Nuclear Information System (INIS)

    Townsley, M.

    1990-01-01

    Information stored on the world's largest data bank concerning the health of nuclear industry workers is to be handed over to researchers at Birmingham University by the US Department of Energy. The data bank contains detailed information on 300,000 nuclear employees, going back to the 1940s. Such a large sample size will allow the results of a previous study conducted on workers in the US nuclear industry to be verified. That study was concluded in 1978 and showed that the risk estimates set by the International Commission on Radiological Protection (ICRP) were between 10 and 30 times too low. The current ICRP estimate allows workers up to 50mSv of exposure to low level radiation per year. Risk estimates have been derived from data relating to the atomic bombings of Hiroshima and Nagasaki. However in those cases the radiation doses were relatively high but over a short period. In the nuclear industry the doses are lower but are long term and this may account for the apparent anomalies such as the incidence of leukaemia amongst children whose fathers have worked in the nuclear industry compared with that for the children whose fathers received radiation doses from the atomic bombings. It is expected the study will show that low-level radiation is more damaging than has previously been thought. (author)

  4. Bisphenol A levels in human urine.

    Science.gov (United States)

    Matsumoto, Akiko; Kunugita, Naoki; Kitagawa, Kyoko; Isse, Toyohi; Oyama, Tsunehiro; Foureman, Gary L; Morita, Masatoshi; Kawamoto, Toshihiro

    2003-01-01

    The estrogenic effects of bisphenol A (BPA) have been reported in human cells (E-screen assays) and in (italic)in vivo(/italic) studies of rodents, although the latter reports remain controversial, as do the exposure levels and adverse health effects of BPA in humans. In this study we report on an analytical high-performance liquid chromatography/fluorescence method for BPA and its conjugate in human urine and on the application of this method in two student cohorts. Urine, along with information on smoking, alcohol intake, and coffee/tea consumption, was collected in two different years from two different groups of university students, 50 in 1992 and 56 in 1999. Overall, the urinary BPA levels in the students in 1992 were significantly higher than were those in 1999. The BPA levels were also positively correlated with coffee and tea consumption in the 1992 cohort but not in the 1999 cohort. We speculate that recent changes made in Japan regarding the interior coating of cans used to package these beverages may partly explain these findings. PMID:12515686

  5. Equivalent Dynamic Models.

    Science.gov (United States)

    Molenaar, Peter C M

    2017-01-01

    Equivalences of two classes of dynamic models for weakly stationary multivariate time series are discussed: dynamic factor models and autoregressive models. It is shown that exploratory dynamic factor models can be rotated, yielding an infinite set of equivalent solutions for any observed series. It also is shown that dynamic factor models with lagged factor loadings are not equivalent to the currently popular state-space models, and that restriction of attention to the latter type of models may yield invalid results. The known equivalent vector autoregressive model types, standard and structural, are given a new interpretation in which they are conceived of as the extremes of an innovating type of hybrid vector autoregressive models. It is shown that consideration of hybrid models solves many problems, in particular with Granger causality testing.

  6. Sarcoptes scabiei mites modulate gene expression in human skin equivalents.

    Directory of Open Access Journals (Sweden)

    Marjorie S Morgan

    Full Text Available The ectoparasitic mite, Sarcoptes scabiei that burrows in the epidermis of mammalian skin has a long co-evolution with its hosts. Phenotypic studies show that the mites have the ability to modulate cytokine secretion and expression of cell adhesion molecules in cells of the skin and other cells of the innate and adaptive immune systems that may assist the mites to survive in the skin. The purpose of this study was to identify genes in keratinocytes and fibroblasts in human skin equivalents (HSEs that changed expression in response to the burrowing of live scabies mites. Overall, of the more than 25,800 genes measured, 189 genes were up-regulated >2-fold in response to scabies mite burrowing while 152 genes were down-regulated to the same degree. HSEs differentially expressed large numbers of genes that were related to host protective responses including those involved in immune response, defense response, cytokine activity, taxis, response to other organisms, and cell adhesion. Genes for the expression of interleukin-1α (IL-1α precursor, IL-1β, granulocyte/macrophage-colony stimulating factor (GM-CSF precursor, and G-CSF precursor were up-regulated 2.8- to 7.4-fold, paralleling cytokine secretion profiles. A large number of genes involved in epithelium development and keratinization were also differentially expressed in response to live scabies mites. Thus, these skin cells are directly responding as expected in an inflammatory response to products of the mites and the disruption of the skin's protective barrier caused by burrowing. This suggests that in vivo the interplay among these skin cells and other cell types, including Langerhans cells, dendritic cells, lymphocytes and endothelial cells, is responsible for depressing the host's protective response allowing these mites to survive in the skin.

  7. Sarcoptes scabiei Mites Modulate Gene Expression in Human Skin Equivalents

    Science.gov (United States)

    Morgan, Marjorie S.; Arlian, Larry G.; Markey, Michael P.

    2013-01-01

    The ectoparasitic mite, Sarcoptes scabiei that burrows in the epidermis of mammalian skin has a long co-evolution with its hosts. Phenotypic studies show that the mites have the ability to modulate cytokine secretion and expression of cell adhesion molecules in cells of the skin and other cells of the innate and adaptive immune systems that may assist the mites to survive in the skin. The purpose of this study was to identify genes in keratinocytes and fibroblasts in human skin equivalents (HSEs) that changed expression in response to the burrowing of live scabies mites. Overall, of the more than 25,800 genes measured, 189 genes were up-regulated >2-fold in response to scabies mite burrowing while 152 genes were down-regulated to the same degree. HSEs differentially expressed large numbers of genes that were related to host protective responses including those involved in immune response, defense response, cytokine activity, taxis, response to other organisms, and cell adhesion. Genes for the expression of interleukin-1α (IL-1α) precursor, IL-1β, granulocyte/macrophage-colony stimulating factor (GM-CSF) precursor, and G-CSF precursor were up-regulated 2.8- to 7.4-fold, paralleling cytokine secretion profiles. A large number of genes involved in epithelium development and keratinization were also differentially expressed in response to live scabies mites. Thus, these skin cells are directly responding as expected in an inflammatory response to products of the mites and the disruption of the skin’s protective barrier caused by burrowing. This suggests that in vivo the interplay among these skin cells and other cell types, including Langerhans cells, dendritic cells, lymphocytes and endothelial cells, is responsible for depressing the host’s protective response allowing these mites to survive in the skin. PMID:23940705

  8. Low-level viremia and proviral DNA impede immune reconstitution in HIV-1-infected patients receiving highly active antiretroviral therapy

    DEFF Research Database (Denmark)

    Ostrowski, Sisse R; Katzenstein, Terese L; Thim, Per T.

    2005-01-01

    Immunological and virological consequences of low-level viremia in human immunodeficiency virus (HIV) type 1-infected patients receiving highly active antiretroviral therapy (HAART) remain to be determined....

  9. Assessment of LANL solid low-level mixed waste documentation

    International Nuclear Information System (INIS)

    Jennrich, E.A.; Lund, D.M.; Davis, K.D.; Hoevemeyer, S.S.

    1991-04-01

    DOE Order 5820.2A requires that a system performance assessment be conducted to assure efficient and compliant management of all radioactive waste. The objective of this report is to determine the present status of the Radioactive Waste Operations Section and the Chemical Waste Operations Section capabilities regarding preparation and maintenance of appropriate criteria, plans, and procedures. Additionally, a comparison is made which identifies areas where these documents are not presently in existence or being fully implemented. The documents being assessed in this report are: Solid Low-Level Mixed Waste Acceptance Criteria, Solid Low-Level Mixed Waste Characterization Plan, Solid Low-Level Mixed waste Certification Plan, Solid Low-Level Mixed Waste Acceptance Procedures, Solid Low-Level Mixed Waste characterization Procedures, Solid Low-Level Mixed Waste Certification Procedures, Solid Low-Level Mixed Waste Training Procedures, and Solid Low-Level Mixed Waste Recordkeeping Requirements. This report compares the current status of preparation and implementation, by the Radioactive Waste Operations Section and the Chemical Waste Operations Section, of these documents to the requirements of DOE 5820.2A,. 40 CFR 260 to 270, and to recommended practice. Chapters 2 through 9 of the report presents the results of the comparison in tabular form for each of the documents being assessed, followed by narrative discussion of all areas which are perceived to be unsatisfactory or out of compliance with respect to the availability and content of the documents. The final subpart of each of the following chapters provides recommendations where documentation practices may be improved to achieve compliance or to follow the recommended practice

  10. Whole-cell pertussis vaccine induces low antibody levels in human immunodeficiency virus-infected children living in sub-Saharan Africa.

    Science.gov (United States)

    Tejiokem, Mathurin C; Njamkepo, Elisabeth; Gouandjika, Ionela; Rousset, Dominique; Béniguel, Lydie; Bilong, Catherine; Tene, Gilbert; Penda, Ida; Ngongueu, Carine; Gody, Jean C; Guiso, Nicole; Baril, Laurence

    2009-04-01

    The WHO recommendations for the immunization of children infected with human immunodeficiency virus (HIV) differ slightly from the guidelines for uninfected children. The introduction of antiretroviral therapy for HIV-infected infants should considerably prolong their life expectancy. The question of the response to the whole-cell pertussis (wP) vaccine should now be addressed, particularly in countries in which pertussis remains endemic. To evaluate the persistence of antibodies to the wP vaccine in HIV-infected and uninfected children who had previously received this vaccine in routine clinical practice, we conducted a cross-sectional study of children aged 18 to 36 months, born to HIV-infected mothers and living in Cameroon or the Central African Republic. We tested blood samples for antibodies to the wP vaccine and for antibodies to diphtheria and tetanus toxoids (D and T, respectively) in the context of the use of a combined DTwP vaccine. We enrolled 50 HIV-infected children and 78 uninfected, HIV-exposed children in the study. A lower proportion of HIV-infected children than uninfected children had antibodies against the antigens tested for all valences of the DTwP vaccine. Agglutinin levels were substantially lower in HIV-infected than in HIV-exposed but uninfected children (30.0% versus 55.1%, respectively; P = 0.005). We also observed a high risk of low antibody levels in response to the DTwP vaccine in HIV-infected children with severe immunodeficiency (CD4 T-cell level, <25%). The concentrations of antibodies induced by the DTwP vaccine were lower in HIV-infected children than in uninfected children. This study supports the need for a booster dose of the DTwP vaccine in order to maintain high antibody levels in HIV-infected children.

  11. 1986 Annual report on Low-Level Radioactive Waste Management progress

    International Nuclear Information System (INIS)

    1987-06-01

    This report summarizes the progress of states and compact regions without low-level waste disposal sites (non-sited compact regions and nonmember states) in 1986 in siting new low-level waste disposal facilities. It also reports the volume of low-level waste received for disposal in 1986 by commercially operated low-level waste disposal facilities. 6 figs., 7 tabs

  12. Dose determination algorithms for a nearly tissue equivalent multi-element thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Moscovitch, M.; Chamberlain, J.; Velbeck, K.J.

    1988-01-01

    In a continuing effort to develop dosimetric systems that will enable reliable interpretation of dosimeter readings in terms of the absorbed dose or dose-equivalent, a new multi-element TL dosimeter assembly for Beta and Gamma dose monitoring has been designed. The radiation-sensitive volumes are four LiF-TLD elements, each covered by its own unique filter. For media-matching, care has been taken to employ nearly tissue equivalent filters of thicknesses of 1000 mg/cm 2 and 300 mg/cm 2 for deep dose and dose to the lens-of-the-eye measurements respectively. Only one metal filter (Cu) is employed to provide low energy photon discrimination. A Thin TL element (0.09 mm thick) is located behind an open window designed to improve the energy under-response to low energy beta rays and to provide closer estimate of the shallow dose equivalent. The deep and shallow dose equivalents are derived from the correlation of the response of the various TL elements to the above quantities through computations based on previously defined relationships obtained from experimental results. The theoretical formalization for the dose calculation algorithms is described in detail, and provides a useful methodology which can be applied to different tissue-equivalent dosimeter assemblies. Experimental data has been obtained by performing irradiation according to the specifications established by DOELAP, using 27 types of pure and mixed radiation fields including Cs-137 gamma rays, low energy photons down to 20 keV, Sr/Y-90, Uranium, and Tl-204 beta particles

  13. Energy response of detectors to alpha/beta particles and compatibility of the equivalent factors

    International Nuclear Information System (INIS)

    Lin Bingxing; Li Guangxian; Lin Lixiong

    2011-01-01

    By measuring detect efficiency and equivalent factors of alpha/beta radiation with different energies on three types of detectors, this paper compares compatibility of their equivalent factors and discusses applicability of detectors to measuring total alpha/beta radiation. The result shows the relationship between efficiency of alpha/beta radiation and their energies on 3 types of detectors, such as scintillation and proportional and semiconductor counters, are overall identical. Alpha count efficiency display exponential relation with alpha-particle energy. While beta count efficiency display logarithm relation with beta-particle energy, but the curves appears deflection at low energy. Comparison test of energy response also shows that alpha and beta equivalent factors of scintillation and proportional counters have a good compatibility, and alpha equivalent factors of the semiconductor counters are in good agreement with those of the above two types of counters, but beta equivalent factors have obvious difference, or equivalent factors of low energy beta-particle are lower than those of other detectors. So, the semiconductor counter can not be used for measuring total radioactivity or for the measurements for the purpose of food safety. (authors)

  14. The Role of Low-Level Laser in Periodontal Surgeries

    Science.gov (United States)

    Sobouti, Farhad; Khatami, Maziar; Heydari, Mohaddase; Barati, Maryam

    2015-01-01

    Treatment protocols with low-level Laser (also called ‘soft laser therapy) have been used in health care systems for more than three decades. Bearing in mind the suitable sub-cellular absorption and the cellular-vascular impacts, low-level laser may be a treatment of choice for soft tissues. Low-level lasers have played crucial and colorful roles in performing periodontal surgeries. Their anti-inflammatory and painless effects have been variously reported in in-vitro studies. In this present review article, searches have been made in Pub Med, Google Scholar, and Science Direct, focusing on the studies which included low-level lasers, flap-periodontal surgeries, gingivectomy, and periodontal graft. The present study has sought to review the cellular impacts of low-level lasers and its role on reducing pain and inflammation following soft tissue surgical treatments. PMID:25987968

  15. Guidelines for interim storage of low level waste

    International Nuclear Information System (INIS)

    Hornibrook, C.; Castagnacci, A.; Clymer, G.; Kelly, J.; Naughton, M.; Saunders, P.; Stoner, P.; Walker, N.; Cazzolli, R.; Dettenmeier, R.; Loucks, L.; Rigsby, M.; Spall, M.; Strum, M.

    1992-12-01

    This report presents an overview of on-site storage of Low Level Waste while providing guidelines for using the complete Interim On-Site Storage of Low Level Waste report series. Overall, this report provides a methodology for planning and implementing on-site storage

  16. Directions in low-level radioactive-waste management. Incentives and compensation: providing resources for communities hosting low-level waste facilities

    International Nuclear Information System (INIS)

    1982-10-01

    State responsibility for the management of low-level radioactive waste necessitates the selection of candidate locations for a disposal facility. Concern over potential impacts can be expected from segments of the citizenry neighboring a proposed site. A number of national organizations comprising state and local officials have recommended the use of incentives and compensation to help offset the negative local impacts. This document explores that concept. Discussion provides background information on potential local impacts from a low-level waste facility and considers the nature and types of incentives and compensation benefits that could be provided. The document then examines realistic options for planning and implementing the benefit program. This information is intended, primarily, to assist state officials - executive, legislative, and agency - in planning for and managing low-level waste disposal facilities

  17. Low-level arsenic exposure via drinking water consumption and female fecundity - A preliminary investigation

    Energy Technology Data Exchange (ETDEWEB)

    Susko, Michele L. [Department of Epidemiology and Biostatistics, University at Albany, State University of New York, Rensselaer, New York (United States); Bloom, Michael S., E-mail: mbloom@albany.edu [Department of Epidemiology and Biostatistics, University at Albany, State University of New York, Rensselaer, New York (United States); Department of Environmental Health Sciences, University at Albany, State University of New York, Rensselaer, New York (United States); Neamtiu, Iulia A. [Health Department, Environmental Health Center, Cluj-Napoca (Romania); IMOGEN Research Institute, Cluj-Napoca (Romania); Appleton, Allison A. [Department of Epidemiology and Biostatistics, University at Albany, State University of New York, Rensselaer, New York (United States); Surdu, Simona [Department of Environmental Health Sciences, University at Albany, State University of New York, Rensselaer, New York (United States); Pop, Cristian [Physico-chemical and Biotoxicological Analysis Laboratory, Environmental Health Center, Cluj-Napoca (Romania); Cluj School of Public Health - College of Political, Administrative and Communication Sciences, Babeș-Bolyai University, Cluj-Napoca (Romania); Faculty of Environmental Science and Engineering, Babeș-Bolyai University, Cluj-Napoca (Romania); Fitzgerald, Edward F. [Department of Epidemiology and Biostatistics, University at Albany, State University of New York, Rensselaer, New York (United States); Department of Environmental Health Sciences, University at Albany, State University of New York, Rensselaer, New York (United States); Anastasiu, Doru [University of Medicine and Pharmacy “Victor Babeș”, Timișoara (Romania); Obstetrics and Gynecology Department of the Emergency County Hospital, Timișoara (Romania); and others

    2017-04-15

    High level arsenic exposure is associated with reproductive toxicity in experimental and observational studies; however, few data exist to assess risks at low levels. Even less data are available to evaluate the impact of low level arsenic exposure on human fecundity. Our aim in this pilot study was a preliminary evaluation of associations between low level drinking water arsenic contamination and female fecundity. This retrospective study was conducted among women previously recruited to a hospital-based case-control study of spontaneous pregnancy loss in Timiá¹£ County, Romania. Women (n=94) with planned pregnancies of 5–20 weeks gestation completed a comprehensive physician-administered study questionnaire and reported the number of menstrual cycles attempting to conceive as the time to pregnancy (TTP). Drinking water samples were collected from residential drinking water sources and we determined arsenic levels using hydride generation-atomic absorption spectrometry (HG-AAS). Multivariable Cox-proportional hazards regression with Efron approximation was employed to evaluate TTP as a function of drinking water arsenic concentrations among planned pregnancies, adjusted for covariates. There was no main effect for drinking water arsenic exposure, yet the conditional probability for pregnancy was modestly lower among arsenic exposed women with longer TTPs, relative to women with shorter TTPs, and relative to unexposed women. For example, 1 µg/L average drinking water arsenic conferred 5%, 8%, and 10% lower likelihoods for pregnancy in the 6th, 9th, and 12th cycles, respectively (P=0.01). While preliminary, our results suggest that low level arsenic contamination in residential drinking water sources may further impair fecundity among women with longer waiting times; however, this hypothesis requires confirmation by a future, more definitive study. - Highlights: • We assessed low level drinking water arsenic as a predictor of fecundability. • Arsenic did

  18. Low-level arsenic exposure via drinking water consumption and female fecundity - A preliminary investigation

    International Nuclear Information System (INIS)

    Susko, Michele L.; Bloom, Michael S.; Neamtiu, Iulia A.; Appleton, Allison A.; Surdu, Simona; Pop, Cristian; Fitzgerald, Edward F.; Anastasiu, Doru

    2017-01-01

    High level arsenic exposure is associated with reproductive toxicity in experimental and observational studies; however, few data exist to assess risks at low levels. Even less data are available to evaluate the impact of low level arsenic exposure on human fecundity. Our aim in this pilot study was a preliminary evaluation of associations between low level drinking water arsenic contamination and female fecundity. This retrospective study was conducted among women previously recruited to a hospital-based case-control study of spontaneous pregnancy loss in Timiá¹£ County, Romania. Women (n=94) with planned pregnancies of 5–20 weeks gestation completed a comprehensive physician-administered study questionnaire and reported the number of menstrual cycles attempting to conceive as the time to pregnancy (TTP). Drinking water samples were collected from residential drinking water sources and we determined arsenic levels using hydride generation-atomic absorption spectrometry (HG-AAS). Multivariable Cox-proportional hazards regression with Efron approximation was employed to evaluate TTP as a function of drinking water arsenic concentrations among planned pregnancies, adjusted for covariates. There was no main effect for drinking water arsenic exposure, yet the conditional probability for pregnancy was modestly lower among arsenic exposed women with longer TTPs, relative to women with shorter TTPs, and relative to unexposed women. For example, 1 µg/L average drinking water arsenic conferred 5%, 8%, and 10% lower likelihoods for pregnancy in the 6th, 9th, and 12th cycles, respectively (P=0.01). While preliminary, our results suggest that low level arsenic contamination in residential drinking water sources may further impair fecundity among women with longer waiting times; however, this hypothesis requires confirmation by a future, more definitive study. - Highlights: • We assessed low level drinking water arsenic as a predictor of fecundability. • Arsenic did

  19. Ecodosimetry weighting factor (eR) for non-human biota

    International Nuclear Information System (INIS)

    Trivedi, A.; Gentner, N.E.

    2000-01-01

    The ICRP's radiological protection guidance for humans recognizes that equal absorbed doses of different types of radiation can have different biological effects in humans. ICRP publication 60 thus prescribes radiation weighting factors, w R values, to modify the absorbed dose (Gy) to effective dose (Sv) to enable the risk from different types of radiation to be compared on an equivalent basis. The w R values are selected on the basis of various considerations, including the linear energy transfer of the radiation and relative biological effectiveness (RBE) values (which are the ratios of the absorbed dose of reference to test radiation that produce an equivalent level of effect, for a given endpoint, system and dose level). There is no similar factor for non-human biota. It would be useful to have one: assessment of possible impacts on non-human biota (particularly from alpha-emitters and tritium beta-rays) is important for Canadian nuclear facilities. We propose a radiation equivalency factor 'e R ' for biota to fulfill a role equivalent to that occupied by w R in human radiation protection. RBE values for deterministic effects such as reproduction, fecundity and survival in biota are the critical bases for selection of e R values. These deterministic effects in populations are far more relevant to the assessment endpoints in ecological risk assessment than are stochastic effects, to which RBE values in human radiation protection relate. For tritium β-rays, most determinations support RBE values of 2-3 for deterministic effects when referenced to gamma radiation but little more than unity when x-rays are the reference radiation. This is because x-rays themselves have RBE -2 if referenced to gamma rays. Despite this, the ICRP assigns a w R of 1 to all electrons and all photons, including tritium beta-rays. Therefore, if e R is constrained to an integer, 1 is more appropriate than a value of 2 for tritium beta-rays. An RBE factor of 200-300 for alpha particles in

  20. A mechanistic overview of health associated effects of low levels of organochlorine and organophosphorous pesticides

    International Nuclear Information System (INIS)

    Androutsopoulos, Vasilis P.; Hernandez, Antonio F.; Liesivuori, Jyrki; Tsatsakis, Aristidis M.

    2013-01-01

    Organochlorine and organophosphate pesticides are compounds that can be detected in human populations as a result of occupational or residential exposure. Despite their occurrence in considerably low levels in humans, their biological effects are hazardous since they interact with a plethora of enzymes, proteins, receptors and transcription factors. In this review we summarize the cell and molecular effects of organochlorine and organophosphate pesticides with respect to their toxicity, with particular emphasis on glucose and lipid metabolism, their interaction with some members of the nuclear receptor family of ligand-activated transcription factors, including the steroid and peroxisome proliferator activated receptors that changes the expression of genes involved in lipid metabolism and xenobiotic detoxification. More importantly, evidence regarding the metabolic degradation of pesticides and their accumulation in tissues is presented. Potential non-cholinergic mechanisms after long-term low-dose organophosphate exposure resulting in neurodevelopmental outcomes and neurodegeneration are also addressed. We conclude that the mechanism of pesticide-mediated toxicity is a combination of various enzyme-inhibitory, metabolic and transcriptional events acting at the cellular and molecular level

  1. Residual endotoxin contaminations in recombinant proteins are sufficient to activate human CD1c+ dendritic cells.

    Directory of Open Access Journals (Sweden)

    Harald Schwarz

    Full Text Available Many commercially available recombinant proteins are produced in Escherichia coli, and most suppliers guarantee contamination levels of less than 1 endotoxin unit (EU. When we analysed commercially available proteins for their endotoxin content, we found contamination levels in the same range as generally stated in the data sheets, but also some that were higher. To analyse whether these low levels of contamination have an effect on immune cells, we stimulated the monocytic cell line THP-1, primary human monocytes, in vitro differentiated human monocyte-derived dendritic cells, and primary human CD1c+ dendritic cells (DCs with very low concentrations of lipopolysaccharide (LPS; ranging from 0.002-2 ng/ml. We show that CD1c+ DCs especially can be activated by minimal amounts of LPS, equivalent to the levels of endotoxin contamination we detected in some commercially available proteins. Notably, the enhanced endotoxin sensitivity of CD1c+ DCs was closely correlated with high CD14 expression levels observed in CD1c+ DCs that had been maintained in cell culture medium for 24 hours. When working with cells that are particularly sensitive to LPS, even low endotoxin contamination may generate erroneous data. We therefore recommend that recombinant proteins be thoroughly screened for endotoxin contamination using the limulus amebocyte lysate test, fluorescence-based assays, or a luciferase based NF-κB reporter assay involving highly LPS-sensitive cells overexpressing TLR4, MD-2 and CD14.

  2. Storage for low-level and intermediate-level radioactive wastes

    International Nuclear Information System (INIS)

    1992-11-01

    The objective of this report was to assess whether three nominated sites in Norway for underground storage of low-level and intermediate-level radioactive wastes would comply with safety standards and applicable laws and regulations. The site selection criteria are described and the report evaluates the technical, environmental and socio-economic suitability of the different sites. The site selection process eliminated two of the nominated sites, whereas one site was singled out. 28 refs., 14 figs., 10 tabs

  3. Aquaporin-1-Mediated Effects of Low Level He-Ne Laser Irradiation on Human Erythrocytes

    Directory of Open Access Journals (Sweden)

    Gang-Yue Luo

    2012-01-01

    Full Text Available The role of membrane aquaporin-1 (APQ-1 in the photobiomodulation (PBM on erythrocyte deformability will be studied in this paper with human dehydrated erythrocytes as echinocytic shape alterations lead to decreased cellular deformability. Human dehydrated erythrocytes were irradiated with low intensity He-Ne laser irradiation (LHNL at 0.9, 1.8, 2.7, and 4.4 mW/cm2 for 5, 15, and 30 min, respectively, and APQ-1 inhibitor, 0.2 μmol/L HgCl2, was used to study the role of APQ-1 in mediating PBM with LHNL at 4.4 mW/cm2 for 5 min. Comprehensive morphological parameters of an intact cell such as contact area, perimeter, roundness and erythrocyte elongation index (EEI were measured to characterize erythrocyte deformability with fast micro multi-channel spectrophotometer. It was observed that the dosage of LHNL improvement of the morphological parameters of dehydrated erythrocytes was morphological-parameter-dependent, but the Bunsen-Roscoe rule did not hold for roundness. The LHNL at 4.4 mW/cm2 for 5 min significantly improved the contact area (P<0.05 and EEI (P<0.05 of the dehydrated erythrocytes, but the improvement was significantly inhibited by 0.2 μmol/L HgCl2 (P<0.05. It was concluded that AQP-1 might mediate the effects of LHNL on erythrocyte deformability, which supports the membranotropic mechanism of PBM.

  4. Generation of a human immunodeficiency virus type 1 chronically infected monkey B cell line expressing low levels of endogenous TRIM5alpha.

    Science.gov (United States)

    Ridolfi, Barbara; Catone, Stefania; Sgarbanti, Marco; Sernicola, Leonardo; Battistini, Angela; Parolin, Cristina; Titti, Fausto; Borsetti, Alessandra

    2009-12-01

    Several innate cellular antiviral factors exist in mammalian cells that prevent the replication of retroviruses. Among them, the tripartite motif protein (TRIM)5alpha has been shown to block human immunodeficiency virus type 1 (HIV-1) infection in several types of Old World monkey cells. Here we report a novel HIV-1 chronically infected monkey B cell line, F6/HIV-1, characterized by very low levels of TRIM5alpha expression that allows HIV-1 to overcome the restriction. Virus produced by F6/HIV-1 cells fails to infect monkey cells but retains the ability to infect human peripheral blood mononuclear cells (PBMCs) and T cell lines, although with a reduced infectivity compared to the input virus. Ultrastructural analyses revealed the presence of budding virions at the F6/HIV-1 cells plasma membrane characterized by a typical conical core shell. To our knowledge F6/HIV-1 is the first monkey cell line chronically infected by HIV-1 and able to release infectious particles thus representing a useful tool to gain further insights into the molecular mechanisms of HIV-1 pathogenesis.

  5. Free radicals and low-level photon emission in human pathogenesis: state of the art.

    Science.gov (United States)

    Van Wijk, Roeland; Van Wijk, Eduard P A; Wiegant, Fred A C; Ives, John

    2008-05-01

    Convincing evidence supports a role for oxidative stress in the pathogenesis of many chronic diseases. The model includes the formation of radical oxygen species (ROS) and the misassembly and aggregation of proteins when three tiers of cellular defence are insufficient: (a) direct antioxidative systems, (b) molecular damage repairing systems, and (c) compensatory chaperone synthesis. The aim of the present overview is to introduce (a) the basics of free radical and antioxidant metabolism, (b) the role of the protein quality control system in protecting cells from free radical damage and its relation to chronic diseases, (c) the basics of the ultraweak luminescence as marker of the oxidant status of biological systems, and (d) the research in human photon emission as a non-invasive marker of oxidant status in relation to chronic diseases. In considering the role of free radicals in disease, both their generation and their control by the antioxidant system are part of the story. Excessive free radical production leads to the production of heat shock proteins and chaperone proteins as a second line of protection against damage. Chaperones at the molecular level facilitate stress regulation vis-à-vis protein quali y control mechanisms. The manifestation of misfolded proteins and aggregates is a hallmark of a range of neurodegenerative disorders including Alzheimer's disease, Parkinson's disease, amylotrophic lateral sclerosis, polyglutamine (polyQ) diseases, diabetes and many others. Each of these disorders exhibits aging-dependent onset and a progressive, usually fatal clinical course. The second part reviews the current status of human photon emission techniques and protocols for recording the human oxidative status. Sensitive photomultiplier tubes may provide a tool for non-invasive and continuous monitoring of oxidative metabolism. In that respect, recording ultraweak luminescence has been favored compared to other indirect assays. Several biological models have

  6. Study on the neutron dosimetric characteristics of Tissue Equivalent Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Nunomiya, T.; Kim, E.; Kurosawa, T.; Taniguchi, S.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Tsujimura, N.; Momose, T.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Environment and Safety Division, Tokai Works, Tokai, Ibaraki (Japan)

    1999-03-01

    The neutron dosimetric characteristics of TEPC (Tissue Equivalent Proportional Counter) has been investigated under a cooperative study between Tohoku University and JNC since 1997. This TEPC is a spherical, large volume, single-wire proportional counter (the model LETSW-5, manufactured by Far West Technology, Inc.) and filled with a tissue equivalent gas in a spherical detector of the A-150 tissue equivalent plastic. The TEPC can measure the spectra of absorbed dose in LET and easily estimate the tissue equivalent dose to neutron. This report summarizes the dosimetric characteristics of TEPC to the monoenergetic neutrons with energy from 8 keV to 15 MeV. It is found that TEPC can estimate the ambient dose equivalent, H*(10), with an accuracy from 0.9 to 2 to the neutron above 0.25 MeV and TEPC has a good counting efficiency enough to measure neutron doses with low dose rate at the stray neutron fields. (author)

  7. Human-Level Artificial Intelligence? Be Serious!

    OpenAIRE

    Nilsson, Nils J.

    2005-01-01

    I claim that achieving real human-level artificial intelligence would necessarily imply that most of the tasks that humans perform for pay could be automated. Rather than work toward this goal of automation by building special-purpose systems, I argue for the development of general-purpose, educable systems that can learn and be taught to perform any of the thousands of jobs that humans can perform. Joining others who have made similar proposals, I advocate beginning with a system that has mi...

  8. 1992 annual report on low-level radioactive waste management progress

    International Nuclear Information System (INIS)

    1993-11-01

    This report summarizes the progress States and compact regions made during 1992 in establishing new low-level radioactive waste disposal facilities. It also provides summary information on the volume of low-level radioactive waste received for disposal in 1992 by commercially operated low-level radioactive waste disposal facilities. This report is in response to section 7 (b) of the Low-Level Radioactive Waste Policy Act

  9. Monte Carlo simulation of neutron irradiation facility developed for accelerator based in vivo neutron activation measurements in human hand bones

    International Nuclear Information System (INIS)

    Aslam; Prestwich, W.V.; McNeill, F.E.; Waker, A.J.

    2006-01-01

    The neutron irradiation facility developed at the McMaster University 3 MV Van de Graaff accelerator was employed to assess in vivo elemental content of aluminum and manganese in human hands. These measurements were carried out to monitor the long-term exposure of these potentially toxic trace elements through hand bone levels. The dose equivalent delivered to a patient during irradiation procedure is the limiting factor for IVNAA measurements. This article describes a method to estimate the average radiation dose equivalent delivered to the patient's hand during irradiation. The computational method described in this work augments the dose measurements carried out earlier [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724]. This method employs the Monte Carlo simulation of hand irradiation facility using MCNP4B. Based on the estimated dose equivalents received by the patient hand, the proposed irradiation procedure for the IVNAA measurement of manganese in human hands [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724] with normal (1 ppm) and elevated manganese content can be carried out with a reasonably low dose of 31 mSv to the hand. Sixty-three percent of the total dose equivalent is delivered by non-useful fast group (>10 keV); the filtration of this neutron group from the beam will further decrease the dose equivalent to the patient's hand

  10. Conflict resolution in low-level waste facility siting

    International Nuclear Information System (INIS)

    English, M.R.

    1989-01-01

    Siting a low-level waste facility is only one part of the low-level waste management process. But it is a crucial part, a prism that focuses many of the other issues in low-level waste management. And, as the 1990 and 1992 milestones approach, siting has a urgency that makes the use of alternative dispute resolution (ADR) techniques especially appropriate, to avoid protracted and expensive litigation and to reach creative and durable solutions. Drawing upon literature in the ADR field, this paper discusses ADR techniques as they apply to low-level waste management and the groundwork that must be laid before they can be applied. It also discusses questions that can arise concerning the terms under which negotiations are carried out. The paper then give suggestions for achieving win/win negotiations. Potential objections to negotiated agreements and potential answers to those objections are reviewed, and some requisites for negotiation are given

  11. Acute low-level alcohol consumption reduces phase locking of event-related oscillations in rodents.

    Science.gov (United States)

    Amodeo, Leslie R; Wills, Derek N; Ehlers, Cindy L

    2017-07-14

    Event-related oscillations (EROs) are rhythmic changes that are evoked by a sensory and/or cognitive stimulus that can influence the dynamics of the EEG. EROs are defined by the decomposition of the EEG signal into magnitude (energy) and phase information and can be elicited in both humans and animals. EROs have been linked to several relevant genes associated with ethanol dependence phenotypes in humans and are altered in selectively bred alcohol-preferring rats. However, pharmacological studies are only beginning to emerge investigating the impact low intoxicating doses of ethanol can have on event-related neural oscillations. The main goal of this study was to investigate the effects of low levels of voluntary consumption of ethanol, in rats, on phase locking of EROs in order to give further insight into the acute intoxicating effects of ethanol on the brain. To this end, we allow rats to self-administer unsweetened 20% ethanol over 15 intermittent sessions. This method results in a stable low-dose consumption of ethanol. Using an auditory event-related potential "oddball" paradigm, we investigated the effects of alcohol on the phase variability of EROs from electrodes implanted into the frontal cortex, dorsal hippocampus, and amygdala. We found that intermittent ethanol self-administration was sufficient to produce a significant reduction in overall intraregional synchrony across all targeted regions. These data suggest that phase locking of EROs within brain regions known to be impacted by alcohol may represent a sensitive biomarker of low levels of alcohol intoxication. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Incineration of Low Level Radioactive Vegetation for Waste Volume Reduction

    International Nuclear Information System (INIS)

    Malik, N.P.S.; Rucker, G.G.; Looper, M.G.

    1995-01-01

    The DOE changing mission at Savannah River Site (SRS) are to increase activities for Waste Management and Environmental Restoration. There are a number of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) locations that are contaminated with radioactivity and support dense vegetation, and are targeted for remediation. Two such locations have been studied for non-time critical removal actions under the National Contingency Plan (NCP). Both of these sites support about 23 plant species. Surveys of the vegetation show that radiation emanates mainly from vines, shrubs, and trees and range from 20,000 to 200,000 d/m beta gamma. Planning for removal and disposal of low-level radioactive vegetation was done with two principal goals: to process contaminated vegetation for optimum volume reduction and waste minimization, and for the protection of human health and environment. Four alternatives were identified as candidates for vegetation removal and disposal: chipping the vegetation and packing in carbon steel boxes (lined with synthetic commercial liners) and disposal at the Solid Waste Disposal Facility at SRS; composting the vegetation; burning the vegetation in the field; and incinerating the vegetation. One alternative 'incineration' was considered viable choice for waste minimization, safe handling, and the protection of the environment and human health. Advantages and disadvantages of all four alternatives considered have been evaluated. For waste minimization and ultimate disposal of radioactive vegetation incineration is the preferred option. Advantages of incineration are that volume reduction is achieved and low-level radioactive waste are stabilized. For incineration and final disposal vegetation will be chipped and packed in card board boxes and discharged to the rotary kiln of the incinerator. The slow rotation and longer resident time in the kiln will ensure complete combustion of the vegetative material

  13. 'Omics analysis of low dose acetaminophen intake demonstrates novel response pathways in humans

    International Nuclear Information System (INIS)

    Jetten, Marlon J.A.; Gaj, Stan; Ruiz-Aracama, Ainhoa; Kok, Theo M. de; Delft, Joost H.M. van; Lommen, Arjen; Someren, Eugene P. van; Jennen, Danyel G.J.; Claessen, Sandra M.; Peijnenburg, Ad A.C.M.; Stierum, Rob H.; Kleinjans, Jos C.S.

    2012-01-01

    Acetaminophen is the primary cause of acute liver toxicity in Europe/USA, which led the FDA to reconsider recommendations concerning safe acetaminophen dosage/use. Unfortunately, the current tests for liver toxicity are no ideal predictive markers for liver injury, i.e. they only measure acetaminophen exposure after profound liver toxicity has already occurred. Furthermore, these tests do not provide mechanistic information. Here, 'omics techniques (global analysis of metabolomic/gene-expression responses) may provide additional insight. To better understand acetaminophen-induced responses at low doses, we evaluated the effects of (sub-)therapeutic acetaminophen doses on metabolite formation and global gene-expression changes (including, for the first time, full-genome human miRNA expression changes) in blood/urine samples from healthy human volunteers. Many known and several new acetaminophen-metabolites were detected, in particular in relation to hepatotoxicity-linked, oxidative metabolism of acetaminophen. Transcriptomic changes indicated immune-modulating effects (2 g dose) and oxidative stress responses (4 g dose). For the first time, effects of acetaminophen on full-genome human miRNA expression have been considered and confirmed the findings on mRNA level. 'Omics techniques outperformed clinical chemistry tests and revealed novel response pathways to acetaminophen in humans. Although no definitive conclusion about potential immunotoxic effects of acetaminophen can be drawn from this study, there are clear indications that the immune system is triggered even after intake of low doses of acetaminophen. Also, oxidative stress-related gene responses, similar to those seen after high dose acetaminophen exposure, suggest the occurrence of possible pre-toxic effects of therapeutic acetaminophen doses. Possibly, these effects are related to dose-dependent increases in levels of hepatotoxicity-related metabolites. -- Highlights: ► 'Omics techniques outperformed

  14. Comparison of doubly labeled water with respirometry at low- and high-activity levels

    International Nuclear Information System (INIS)

    Westerterp, K.R.; Brouns, F.; Saris, W.H.; ten Hoor, F.

    1988-01-01

    In previous studies the doubly labeled water method for measuring energy expenditure in free-living humans has been validated against respirometry under sedentary conditions. In the present investigation, energy expenditure is measured simultaneously with doubly labeled water and respirometry at low- and high-activity levels. Over 6 days, five subjects were measured doing mainly sedentary activities like desk work; their average daily metabolic rate was 1.40 +/- 0.09 (SD) times sleeping metabolic rate. Four subjects were measured twice over 3.5 days, including 2 days with heavy bicycle ergometer work, resulting in an average daily metabolic rate of 2.61 +/- 0.25 (SD) times sleeping metabolic rate. At the low-activity level, energy expenditures from the doubly labeled water method were on the average 1.4 +/- 3.9% (SD) larger than those from respirometry. At the high-activity level, the doubly labeled water method yielded values that were 1.0 +/- 7.0% (SD) lower than those from respirometry. Results demonstrate the utility of the doubly labeled water method for the determination of energy expenditure in the range of activity levels in daily life

  15. Plasma PCSK9 levels are significantly modified by statins and fibrates in humans

    Directory of Open Access Journals (Sweden)

    Mbikay Majambu

    2008-06-01

    Full Text Available Abstract Background Proprotein convertase subtilisin kexin-like 9 (PCSK9 is a secreted glycoprotein that is transcriptionally regulated by cholesterol status. It modulates levels of circulating low density lipoprotein cholesterol (LDLC by negatively regulating low density lipoprotein receptor (LDLR levels. PCSK9 variants that result in 'gain of function' have been linked to autosomal dominant hypercholesterolemia, while significant protection from coronary artery disease has been documented in individuals who carry 'loss of function' PCSK9 variants. PCSK9 circulates in human plasma, and we previously reported that plasma PCSK9 is positively correlated with total cholesterol and LDLC in men. Results Herein, we report the effects of two lipid-modulating therapies, namely statins and fibrates, on PCSK9 plasma levels in human subjects. We also document their effects on endogenous PCSK9 and LDLR expression in a human hepatocyte cell line, HepG2, using immunoprecipitation and immunoblot analyses. Changes in plasma PCSK9 following fenofibrate or gemfibrozil treatments (fibric acid derivatives were inversely correlated with changes in LDLC levels (r = -0.558, p = 0.013. Atorvastatin administration (HMGCoA reductase inhibitor significantly increased plasma PCSK9 (7.40%, p = 0.033 and these changes were inversely correlated with changes in LDLC levels (r = -0.393, p = 0.012. Immunoblot analyses of endogenous PCSK9 and LDLR expression by HepG2 cells in response to statins and fibrates showed that LDLR is more upregulated than PCSK9 by simvastatin (2.6× vs 1.5×, respectively at 10 μM, while fenofibrate did not induce changes in either. Conclusion These results suggest that in vivo (1 statins directly increase PCSK9 expression while (2 fibrates affect PCSK9 expression indirectly through its modulation of cholesterol levels and (3 that these therapies could be improved by combination with a PCSK9 inhibitor, constituting a novel hypercholesterolemic therapy

  16. Assessment of DNA damage and Chromosome aberration in human lymphocyte exposed to low dose radiation detected by FISH(Fluorescence In Situ Hybridization) and SCGE(Single Cell Gel Electrophoresis)

    International Nuclear Information System (INIS)

    Chung, Hai Won; Kim, Su Young; Kim, Byung Mo; Kim, Sun Jin; Ha, Sung Whan; Kim, Tae Hwan; Cho, Chul Koo

    2000-01-01

    Comparative study was performed for the assessment of DNA damage and Chromosomal aberration in human lymphocyte exposed to low dose radiation using Fluorescence In Situ Hybridization(FISH) and Single Cell Gel Electrophoresis(SCGE). Chromosomal aberrations in human lymphocyte exposed to radiation at doses of 5, 10, 30 and 50cGy were analysed with whole chromosome-specific probes by human chromosome 1, 2 and 4 according to PAINT system. FISH with chromosome-specific probe has been used to be a valid and rapid method for detection of chromosome rearrangements induced by low dose radiation. The frequencies of stable translocation per cell equivalents were 0.0116, 0.0375, 0.0407, 0.0727 and 0.0814 for 0, 5, 10, 30 and 50cGy, respectively, and those of dicentric were 0.00, 0.0125, 0.174, 0.0291 and 0.0407 respectively. Radiation induced DNA damage in human lymphocyte in a dose-dependent manner at low doses from 5cGy to 50cGy, which were analysed by single Cell Gel Electrophoresis(SCGE). From above results, FISH seemed to be useful for radiation biodosimetry by which the frequencies of stable aberrations in human lymphocyte can be observed more easily than by conventional method and SCGE also seemed to be sensitive method for detecting DNA damage by low dose radiation exposure, so that those methods will improve our technique to perform meaningful biodosimetry for radiation at low doses

  17. Water-equivalence of gel dosimeters for radiology medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M; Vedelago, J.; Perez, P. [Instituto de Fisica Enrique Gaviola - CONICET, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA, Cordoba (Argentina); Chacon, D.; Mattea, F. [Universidad Nacional de Cordoba, FAMAF, Laboratorio de Investigacion e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina); Velasquez, J., E-mail: valente@famaf.unc.edu.ar [ICOS Inmunomedica, Lago Puyehue 01745, Temuco (Chile)

    2017-10-15

    International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography and high-resolution micro computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined by Monte Carlo simulations. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 k Vp) were found to be less than 3% in average. (Author)

  18. Water-equivalence of gel dosimeters for radiology medical imaging

    International Nuclear Information System (INIS)

    Valente, M; Vedelago, J.; Perez, P.; Chacon, D.; Mattea, F.; Velasquez, J.

    2017-10-01

    International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography and high-resolution micro computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined by Monte Carlo simulations. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 k Vp) were found to be less than 3% in average. (Author)

  19. Aspects of research on effects of population exposed to low level radiation in China

    International Nuclear Information System (INIS)

    Wei, L.

    1992-01-01

    Research works of epidemiology and experimental biology concerning health effects on populations exposed to low level ionizing radiation in China have been reviewed, with emphasis on the studies of mortality of malignancies and prevalence of hereditary diseases in a high background radiation area (HBRA) (radiation level is about three times of the control area of normal background CA), where the inhabitant families have lived for many generations. About one million person-years in HBRA and as many in CA were observed for cancer mortality. Statistical analysis showed that no difference was found either in mortality of all cancers or leukemias between HBRA and CA. The incidence of Down Syndrome in HBRA was within the range of spontaneous incidence and dependent on age of maternity. The characteristics of adaptive response induced by low level irradiation in humans as well as in experimental animal lymphocytes observed in Chinese laboratories are also discussed in this presentation

  20. Evaluation of effective dose equivalent from environmental gamma rays

    International Nuclear Information System (INIS)

    Saito, K.; Tsutsumi, M.; Moriuchi, S.; Petoussi, N.; Zankl, M.; Veit, R.; Jacob, P.; Drexler, G.

    1991-01-01

    Organ doses and effective dose equivalents for environmental gamma rays were calculated using human phantoms and Monte Carlo methods accounting rigorously the environmental gamma ray fields. It was suggested that body weight is the dominant factor to determine organ doses. The weight function expressing organ doses was introduced. Using this function, the variation in organ doses due to several physical factors were investigated. A detector having gamma-ray response similar to that of human bodies has been developed using a NaI(Tl) scintillator. (author)

  1. USDOE activities in low-level radioactive waste treatment

    International Nuclear Information System (INIS)

    Vath, J.E.

    1981-01-01

    This paper describes current research, development and demonstration (R, D and D) programs sponsored by the US Department of Energy in the area of low-level radioactive waste treatment. During the twelve month period ending September 30, 1981, 14 prime US Department of Energy contractors were involved with over 40 low-level radioactive waste disposal technology projects. Three specific projects or task areas have been selected for discussion to illustrate new and evolving technologies, and application of technology developed in other waste management areas to low-level waste treatment. The areas to be discussed include a microwave plasma torch incinerator, application of waste vitrification, and decontamination of metal waste by melting

  2. Predisposal Management of Low and Intermediate Level Radioactive Waste. Safety Guide

    International Nuclear Information System (INIS)

    2009-01-01

    The objective of this Safety Guide is to provide regulatory bodies and the operators that generate and manage radioactive waste with recommendations on how to meet the principles and requirements established for the predisposal management of low and intermediate level waste. Contents: 1. Introduction; 2. Protection of human health and the environment; 3. Roles and responsibilities; 4. General safety considerations; 5. Safety features for the predisposal management of LILW; 6. Record keeping and reporting; 7. Safety assessment; 8. Quality assurance; Annex I: Nature and sources of LILW from nuclear facilities; Annex II: Development of specifications for waste packages; Annex III: Site conditions, processes and events for consideration in a safety assessment (external natural phenomena); Annex IV: Site conditions, processes and events for consideration in a safety assessment (external human induced phenomena); Annex V: Postulated initiating events for consideration in a safety assessment (internal phenomena).

  3. Impact of technology applications to the management of low-level radioactive wastes

    International Nuclear Information System (INIS)

    Devgun, J.S.

    1989-01-01

    Low-level radioactive wastes are generated from reactor sources (nuclear power reactors) as well as from nonreactor sources (academic, medical, governmental, and industrial). In recent years, about 50,000 m 3 per year of such wastes have been generated in the United States and about 10,000 m 3 per year in Canada. Direct disposal of these wastes in shallow ground has been a favored method in both countries in the past. In the United States, three operating commercial sites at Barnwell, South Carolina; Beatty, Nevada; and Richland, Washington, receive most of the commercial low-level waste generated. However, with recent advances in waste management, technologies are being applied to achieve optimum goals in terms of protection of human health and safety and the environment, as well as cost-effectiveness. These technologies must be applied from the generation sources through waste minimization and optimum segregation -- followed by waste processing, conditioning, storage, and disposal. A number of technologies that are available and can be applied as appropriate -- given the physical, chemical, and radiological characteristics of the waste -- include shredding, baling, compaction, supercompaction, decontamination, incineration, chemical treatment/conditioning, immobilization, and packaging. Interim and retrievable storage can be accomplished in a wide variety of storage structures, and several types of engineered disposal facility designs are now available. By applying an integrated approach to radioactive waste management, potential adverse impacts on human health and safety and the environment can be minimized. 15 refs., 1 fig., 1 tab

  4. Commercial low-level radioactive waste transportation liability and radiological risk

    Energy Technology Data Exchange (ETDEWEB)

    Quinn, G.J.; Brown, O.F. II; Garcia, R.S.

    1992-08-01

    This report was prepared for States, compact regions, and other interested parties to address two subjects related to transporting low-level radioactive waste to disposal facilities. One is the potential liabilities associated with low-level radioactive waste transportation from the perspective of States as hosts to low-level radioactive waste disposal facilities. The other is the radiological risks of low-level radioactive waste transportation for drivers, the public, and disposal facility workers.

  5. Commercial low-level radioactive waste transportation liability and radiological risk

    International Nuclear Information System (INIS)

    Quinn, G.J.; Brown, O.F. II; Garcia, R.S.

    1992-08-01

    This report was prepared for States, compact regions, and other interested parties to address two subjects related to transporting low-level radioactive waste to disposal facilities. One is the potential liabilities associated with low-level radioactive waste transportation from the perspective of States as hosts to low-level radioactive waste disposal facilities. The other is the radiological risks of low-level radioactive waste transportation for drivers, the public, and disposal facility workers

  6. High-throughput fractionation of human plasma for fast enrichment of low- and high-abundance proteins.

    Science.gov (United States)

    Breen, Lucas; Cao, Lulu; Eom, Kirsten; Srajer Gajdosik, Martina; Camara, Lila; Giacometti, Jasminka; Dupuy, Damian E; Josic, Djuro

    2012-05-01

    Fast, cost-effective and reproducible isolation of IgM from plasma is invaluable to the study of IgM and subsequent understanding of the human immune system. Additionally, vast amounts of information regarding human physiology and disease can be derived from analysis of the low abundance proteome of the plasma. In this study, methods were optimized for both the high-throughput isolation of IgM from human plasma, and the high-throughput isolation and fractionation of low abundance plasma proteins. To optimize the chromatographic isolation of IgM from human plasma, many variables were examined including chromatography resin, mobile phases, and order of chromatographic separations. Purification of IgM was achieved most successfully through isolation of immunoglobulin from human plasma using Protein A chromatography with a specific resin followed by subsequent fractionation using QA strong anion exchange chromatography. Through these optimization experiments, an additional method was established to prepare plasma for analysis of low abundance proteins. This method involved chromatographic depletion of high-abundance plasma proteins and reduction of plasma proteome complexity through further chromatographic fractionation. Purification of IgM was achieved with high purity as confirmed by SDS-PAGE and IgM-specific immunoblot. Isolation and fractionation of low abundance protein was also performed successfully, as confirmed by SDS-PAGE and mass spectrometry analysis followed by label-free quantitative spectral analysis. The level of purity of the isolated IgM allows for further IgM-specific analysis of plasma samples. The developed fractionation scheme can be used for high throughput screening of human plasma in order to identify low and high abundance proteins as potential prognostic and diagnostic disease biomarkers.

  7. Illinois perspective on low level radioactive waste disposal

    International Nuclear Information System (INIS)

    Etchison, D.

    1984-01-01

    Illinois is a big generator of low level radioactive waste. It has had extensive experience with controversial waste disposal and storage facilities. This experience makes it difficult for the public and political leaders in Illinois to support the establishment of new disposal facilities in the state. Yet, with extensive debates and discussions concerning the Low Level Waste Policy Act of 1980 and the proposed Midwest Compact, political leaders and the public are facing up to the fact that they must be responsible for the disposal of the low level radioactive waste generated in the state. The Governor and many political leaders from Illinois support the regional approach and believe it can be an innovative and progressive way for the state to deal with the range of low level waste management and disposal problems. A version of the Midwest Interstate Low Level Waste Compact has become Illinois law, but it has significant differences from the one adopted by five other states. Like other states in the midwest and northeast, Illinois is opposed to Congressional consent of the four pending compacts before the remaining two compacts, the northeast and midwest are sent to Washington and interregional agreements are negotiated between the sited and non-sited regions. A new national system must be established before access to existing commercial disposal becomes restricted

  8. Novel Approach to Treating Androgenetic Alopecia in Females With Photobiomodulation (Low-Level Laser Therapy).

    Science.gov (United States)

    Friedman, Shelly; Schnoor, Patricia

    2017-06-01

    Photobiomodulation, also referred to as low-level laser therapy (LLLT), has been studied and used for (among other diseases) the promotion of hair regrowth. A clinical study was developed to define the physiologic effects that occur when the human hair follicle and surrounding tissue structures are exposed to laser light using a novel device that is fitted with an array of laser diode sources operating at 650 nm and placed inside a sports cap to promote discretion while in use. The study demonstrates that low-level laser treatment of the scalp every other day for 17 weeks using the HANDI-DOME LASER device is a safe and effective treatment for androgenetic alopecia in healthy females between the ages of 18 to 60 with Fitzpatrick skin Types I to IV and Ludwig-Savin Baldness Scale I-2 to II-2 baldness patterns. Subjects receiving LLLT at 650 nm achieved a 51% increase in hair counts as compared with sham-treated control patients in this multicenter randomized controlled trial. These results suggest that the emerging technology of low-level laser therapy may play a potentially significant role in health care providers' armamentarium for the disease androgenic alopecia.

  9. Radioactive waste equivalence

    International Nuclear Information System (INIS)

    Orlowski, S.; Schaller, K.H.

    1990-01-01

    The report reviews, for the Member States of the European Community, possible situations in which an equivalence concept for radioactive waste may be used, analyses the various factors involved, and suggests guidelines for the implementation of such a concept. Only safety and technical aspects are covered. Other aspects such as commercial ones are excluded. Situations where the need for an equivalence concept has been identified are processes where impurities are added as a consequence of the treatment and conditioning process, the substitution of wastes from similar waste streams due to the treatment process, and exchange of waste belonging to different waste categories. The analysis of factors involved and possible ways for equivalence evaluation, taking into account in particular the chemical, physical and radiological characteristics of the waste package, and the potential risks of the waste form, shows that no simple all-encompassing equivalence formula may be derived. Consequently, a step-by-step approach is suggested, which avoids complex evaluations in the case of simple exchanges

  10. Risk comparisons relevant to sea disposal of low level radioactive waste

    International Nuclear Information System (INIS)

    1993-11-01

    This document contains estimates of, and comparisons among, risks to human health posed by exposures to radionuclides, including those associated with low level radioactive wastes dumping at sea, and organic chemical contaminants resulting from seafood consumption. This study was conducted at the request of the Contracting Parties to the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter (the London Convention 1972, formerly referred to as the London Dumping Convention) as a component of a review of the wider political, legal, economic and social aspects of sea dumping of radioactive wastes. The highest potential risks associated with seafood consumption are generally those resulting from exposures to naturally occurring radionuclides. In some representations, the potential risks associated with polychlorinated biphenyls (ΣPCB) and dieldrin in seafood are of the same order as those arising from naturally occurring radionuclides. The peak annual risks resulting from low level radioactive waste dumping at sea, assessed on any rational basis, are at least two orders of magnitude lower than those associated with the ingestion of common organic chemical contaminants in seafood. 47 refs, 4 figs, 13 tabs

  11. Effects of wavelength, beam type and size on cerebral low-level laser therapy by a Monte Carlo study on visible Chinese human

    Directory of Open Access Journals (Sweden)

    Ting Li

    2015-01-01

    Full Text Available Low-level laser therapy (LLLT has been clinically utilized for many indications in medicine requiring protection from cell/tissue death, stimulation of healing and repair of injuries, pain reduction, swelling and inflammation. Presently, the use of LLLT to treat stroke, traumatic brain injury and cognitive dysfunction are attracting growing interest. Near-infrared light is capable of penetrating into the cerebral cortex, allowing noninvasive treatments to be carried out with few treatment-related adverse events. Optimization of LLLT treatment effect is a crucial issue of this field; however, only a few experimental tests on mice for wavelength selection have been reported. We addressed this issue by low-cost, straightforward and quantitative comparisons on light dosage distribution within visible Chinese human head by Monte Carlo modeling of near-infrared light propagation. Optimized selection in wavelength, beam type and size were given based on comparisons among frequently used setups (i.e., wavelengths: 660, 810 and 980 nm; beam type: Gaussian and flat beam; beam diameter: 2, 4 and 6 cm. This study provided an efficient way for guiding the optimization of LLLT setup and selection on wavelength, beam type and size for clinical brain LLLT.

  12. Ocean dumping of low-level radioactive wastes

    International Nuclear Information System (INIS)

    Templeton, W.L.

    1982-10-01

    Scientific bases, developed internationally over the last 20 years, to control and restrict to acceptable levels the resultant radiation doses that potentially could occur from the dumping of low-level radioactive wastes in the deep oceans were presented. The author concluded that present evaluations of the disposal of radioactive wastes into the oceans, coastal and deep ocean, indicate that these are being conducted within the ICRP recommended dose limits. However, there are presently no international institutions or mechanisms to deal with the long-term radiation exposure at low-levels to large numbers of people on a regional basis if not a global level. Recommendations were made to deal with these aspects through the established mechanisms of NEA/OECD and the London Dumping Convention, in cooperation with ICRP, UNSCEAR and the IAEA

  13. Equivalence principles and electromagnetism

    Science.gov (United States)

    Ni, W.-T.

    1977-01-01

    The implications of the weak equivalence principles are investigated in detail for electromagnetic systems in a general framework. In particular, it is shown that the universality of free-fall trajectories (Galileo weak equivalence principle) does not imply the validity of the Einstein equivalence principle. However, the Galileo principle plus the universality of free-fall rotation states does imply the Einstein principle.

  14. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  15. 1989 Annual report on low-level radioactive waste management progress

    International Nuclear Information System (INIS)

    1990-10-01

    This report summarizes the progress during 1989 of states and compacts in establishing new low-level radioactive waste disposal facilities. It also provides summary information on the volume of low-level waste received for disposal in 1989 by commercially operated low-level waste disposal facilities. This report is in response to Section 7(b) of Title I of Public Law 99--240, the Low-Level Radioactive Waste Policy Amendments Act of 1985. 2 figs., 5 tabs

  16. Equivalent models of wind farms by using aggregated wind turbines and equivalent winds

    International Nuclear Information System (INIS)

    Fernandez, L.M.; Garcia, C.A.; Saenz, J.R.; Jurado, F.

    2009-01-01

    As a result of the increasing wind farms penetration on power systems, the wind farms begin to influence power system, and therefore the modeling of wind farms has become an interesting research topic. In this paper, new equivalent models of wind farms equipped with wind turbines based on squirrel-cage induction generators and doubly-fed induction generators are proposed to represent the collective behavior on large power systems simulations, instead of using a complete model of wind farms where all the wind turbines are modeled. The models proposed here are based on aggregating wind turbines into an equivalent wind turbine which receives an equivalent wind of the ones incident on the aggregated wind turbines. The equivalent wind turbine presents re-scaled power capacity and the same complete model as the individual wind turbines, which supposes the main feature of the present equivalent models. Two equivalent winds are evaluated in this work: (1) the average wind from the ones incident on the aggregated wind turbines with similar winds, and (2) an equivalent incoming wind derived from the power curve and the wind incident on each wind turbine. The effectiveness of the equivalent models to represent the collective response of the wind farm at the point of common coupling to grid is demonstrated by comparison with the wind farm response obtained from the detailed model during power system dynamic simulations, such as wind fluctuations and a grid disturbance. The present models can be used for grid integration studies of large power system with an important reduction of the model order and the computation time

  17. Human-Based Human Milk Fortifier as Rescue Therapy in Very Low Birth Weight Infants Demonstrating Intolerance to Bovine-Based Human Milk Fortifier.

    Science.gov (United States)

    Sandhu, Amanjot; Fast, Sharla; Bonnar, Kari; Baier, Ronald John; Narvey, Michael

    2017-11-01

    To describe the results of utilizing a human milk-based human milk fortifier (HMHMF) as rescue therapy to meet nutritional requirements in very low birth weight and preterm infants demonstrating feeding intolerance to bovine-based human milk fortifier (BHMF) in the Canadian Neonatal Intensive Care Unit (NICU) setting. At two Level III NICUs in Winnipeg, MB, Canada, a rescue protocol was implemented to provide HMHMF for infants demonstrating intolerance to BHMF. To qualify for rescue, infants were required to experience two episodes of significant gastrointestinal (GI) symptoms associated with fortification with BHMF. A case series report was conducted retrospectively examining the success of rescue therapy, growth rates, protein, and calorie intakes before and after initiation of HMHMF in seven infants. Seven infants (birth weight 723 ± 247 g, gestation 25.3 ± 3.4 weeks) were treated with rescue fortification with HMHMF. All infants were transitioned off parenteral nutrition (PN) without relapse of GI symptoms. Growth rate, protein, and calorie intakes improved with the use of HMHMF. Very low birth weight and preterm infants with GI intolerance to BHMF were successfully rescued with use of HMHMF. Improvements in growth were achieved without need for supplementation with PN through achievement of sufficient enteral calorie and protein intakes.

  18. An epidermal equivalent assay for identification and ranking potency of contact sensitizers

    Energy Technology Data Exchange (ETDEWEB)

    Gibbs, Susan, E-mail: S.Gibbs@VUMC.nl [Department of Dermatology, VU University Medical Centre, Dept of Oral Cell Biology, ACTA, Amsterdam (Netherlands); Corsini, Emanuela [Laboratory of Toxicology, DiSFeB, Università degli Studi di Milano (Italy); Spiekstra, Sander W. [Department of Dermatology, VU University Medical Centre, Dept of Oral Cell Biology, ACTA, Amsterdam (Netherlands); Galbiati, Valentina [Laboratory of Toxicology, DiSFeB, Università degli Studi di Milano (Italy); Fuchs, Horst W. [CellSystems GmbH, Troisdorf (Germany); DeGeorge, George; Troese, Matthew [MB Research Labs, Spinnerstown, PA (United States); Hayden, Patrick; Deng, Wei [MatTek Corporation, Ashland, MA (United States); Roggen, Erwin [3Rs Management and Consultancy (Denmark)

    2013-10-15

    The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24 h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC{sub 50}) with human and animal data showed a superior correlation with human DSA{sub 05} (μg/cm{sup 2}) data (Spearman r = 0.8500; P value (two-tailed) = 0.0061) compared to LLNA data (Spearman r = 0.5968; P value (two-tailed) = 0.0542). DSA{sub 05} = induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA{sub 05} data (Spearman r = 0.8333; P value (two-tailed) = 0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model. - Highlights: • A potential epidermal equivalent assay to label and classify sensitizers • Il-18 release distinguishes sensitizers from non sensitizers • IL-18 release can rank sensitizer potency

  19. An epidermal equivalent assay for identification and ranking potency of contact sensitizers

    International Nuclear Information System (INIS)

    Gibbs, Susan; Corsini, Emanuela; Spiekstra, Sander W.; Galbiati, Valentina; Fuchs, Horst W.; DeGeorge, George; Troese, Matthew; Hayden, Patrick; Deng, Wei; Roggen, Erwin

    2013-01-01

    The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24 h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC 50 ) with human and animal data showed a superior correlation with human DSA 05 (μg/cm 2 ) data (Spearman r = 0.8500; P value (two-tailed) = 0.0061) compared to LLNA data (Spearman r = 0.5968; P value (two-tailed) = 0.0542). DSA 05 = induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA 05 data (Spearman r = 0.8333; P value (two-tailed) = 0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model. - Highlights: • A potential epidermal equivalent assay to label and classify sensitizers • Il-18 release distinguishes sensitizers from non sensitizers • IL-18 release can rank sensitizer potency • EC50 (chemical

  20. Low-level waste forum meeting reports

    International Nuclear Information System (INIS)

    1992-01-01

    This report provides highlights from the 1992 fall meeting of the Low LEvel Radioactive Waste Forum. Topics included: disposal options after 1992; interregional agreements; management alternatives; policy; and storage

  1. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Quan Chen

    2018-01-01

    Full Text Available Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees’ low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees’ job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice.

  2. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation

    Science.gov (United States)

    Chen, Quan; Tsai, Sang-Bing; Zhou, Jie; Yu, Jian; Chang, Li-Chung; Li, Guodong; Zheng, Yuxiang; Wang, Jiangtao

    2018-01-01

    Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees’ low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees’ job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice. PMID:29301375

  3. An Empirical Study on Low-Carbon: Human Resources Performance Evaluation.

    Science.gov (United States)

    Chen, Quan; Tsai, Sang-Bing; Zhai, Yuming; Zhou, Jie; Yu, Jian; Chang, Li-Chung; Li, Guodong; Zheng, Yuxiang; Wang, Jiangtao

    2018-01-03

    Low-carbon logistics meets the requirements of a low-carbon economy and is the most effective operating model for logistic development to achieve sustainability by coping with severe energy consumption and global warming. Low-carbon logistics aims to reduce carbon intensity rather than simply reduce energy consumption and carbon emissions. Human resources are an important part of the great competition in the logistics market and significantly affect the operations of enterprises. Performance evaluations of human resources are particularly important for low-carbon logistics enterprises with scarce talents. Such evaluations in these enterprises are of great significance for their strategic development. This study constructed a human resource performance evaluation system to assess non-managerial employees' low-carbon job capacity, job performance, and job attitude in the low-carbon logistics sector. The case study results revealed that the investigated company enjoyed initial success after having promoted low-carbon concepts and values to its non-managerial employees, and the success was demonstrated by excellent performance in its employees' job attitude and knowledge. This study adopts the AHP method to reasonably determine an indicator system of performance evaluation and its weight to avoid certain human-caused bias. This study not only fills the gap in the related literature, but can also be applied to industrial practice.

  4. Low-level and mixed waste incinerator survey report

    International Nuclear Information System (INIS)

    Garcia, E.C.

    1988-10-01

    The Low-Level and Mixed Waste Survey Task was initiated to investigate and document current and planned incinerator facilities in the Department of Energy Defense Programs (DOE-DP) system. A survey was mailed to the DOE field offices requesting information regarding existing or planned incinerator facilities located under their jurisdiction. The information requested included type, capacities, uses, costs, and mechanical description of the incinerators. The results of this survey are documented in this report. Nine sites responded to the survey, with eight sites listing nine incineration units in several stages of operations. The Idaho National Engineering Laboratory listed two operational facilities. There are four incinerators that are planned for start-up in 1991. Of the existing incinerators, three are used mostly for low-level wastes, while the planned units will be used for low-level, mixed, and hazardous wastes. This report documents the current state of the incineration facilities in the DOE-DP system and provides a preliminary strategy for management of low-level wastes and a basis for implementing this strategy. 5 refs., 4 figs., 14 tabs

  5. Managing low-level radioactive wastes: a proposed approach

    International Nuclear Information System (INIS)

    Peel, J.W.; Levin, G.B.

    1980-01-01

    In 1978, President Carter established the Interagency Review Group on Nuclear Waste Management (IRG) to review the nation's plans and progress in managing radioactive wastes. In its final report, issued in March 1979, the group recommended that the Department of Energy (DOE) assume responsibility for developing a national plan for the management of low-level wastes. Toward this end, DOE directed that a strategy be developed to guide federal and state officials in resolving issues critical to the safe management of low-level wastes. EG and G Idaho, Inc. was selected as the lead contractor for the Low-Level Waste Management Program and was given responsibility for developing the strategy. A 25 member task force was formed which included individuals from federal agencies, states, industry, universities, and public interest groups. The task force identified nineteen broad issues covering the generation, treatment, packaging, transportation, and disposal of low-level wastes. Alternatives for the resolution of each issue were proposed and recommendations were made which, taken together, form the draft strategy. These recommendations are summarized in this document

  6. Incineration of low level and mixed wastes: 1986

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The University of California at Irvine, in cooperation with the Department of Energy, American Society of Mechanical Engineers, and chapters of the Health Physics Society, coordinated this conference on the Incineration of Low-Level Radioactive and Mixed Wastes, with the guidance of professionals active in the waste management community. The conference was held in April 22-25, 1986 at Sheraton airport hotel Charlotte, North Carolina. Some of the papers' titles were: Protection and safety of different off-gas treatment systems in radioactive waste incineration; performance assessment of refractory samples in the Los Alamos controlled-Air incinerator; incineration systems for low-level and mixed wastes; incineration of low-level radioactive waste in Switzerland-operational experience and future activities

  7. Twelfth annual US DOE low-level waste management conference

    International Nuclear Information System (INIS)

    1990-01-01

    The papers in this document comprise the proceedings of the Department of Energy's Twelfth Annual Low-Level Radioactive Waste Management Conference, which was held in Chicago, Illinois, on August 28 and 29, 1990. General subjects addressed during the conference included: mixed waste, low-level radioactive waste tracking and transportation, public involvement, performance assessment, waste stabilization, financial assurance, waste minimization, licensing and environmental documentation, below-regulatory-concern waste, low-level radioactive waste temporary storage, current challenges, and challenges beyond 1990

  8. 43 CFR 426.11 - Class 1 equivalency.

    Science.gov (United States)

    2010-10-01

    ...) Costs of production; (v) Land development costs; (vi) Water quality and adequacy; (vii) Elevation; (viii... equivalency factors by comparing the weighted average farm size required to produce a given level of income on... measured in terms of net income per acre (reflecting both productivity and costs of production). The...

  9. Equivalence Scales for the Former West Germany

    NARCIS (Netherlands)

    Charlier, E.

    1997-01-01

    Equivalence scales provide answers to questions like how much a household with four children needs to spend compared to a household with two children or how much a childless couple needs to spend compared to a single person household to attain the same welfare level. These are important questions

  10. Radiosensitization of CHO cells by the combination of glutathione depletion and low concentrations of oxygen: The effect of different levels of GSH depletion

    International Nuclear Information System (INIS)

    Clark, E.P.; Epp, E.R.; Zachgo, E.A.; Biaglow, J.E.

    1984-01-01

    Recently, the authors have examined the effect of GSH depletion by BSO on CHO cells equilibrated with oxygen at various concentrations (0.05-4.0%) and irradiated with 50 kVp x-rays. This is of interest because of the uncertain radiosensitizing effect GSH depletion may have on cells equilibrated with low oxygen concentrations. GSH depletion (0.1 mM BSO/24 hrs reduced [GSH] ≅ 10% of control) enhanced the radiosensitizing action of moderate (0.4-4.0%) concentrations of oxygen, i.e., GSH depletion reduced the [O/sub 2/] necessary to achieve an equivalent ER by ≅ 2-3 fold. However, GSH depletion was much more effective as a rediosensitizer when cells were equilibrated with low (<0.4%) concentrations of oxygen, i.e., GSH depletion reduced the [O/sub 2/] necessary to achieve an equivalent ER by 8-10 fold. Furthermore, while the addition of exogenous 5 mM GSH restored the ER to that observed when GSH was not depleted, the intracellular [GSH] was not increased. The results of these studies carried out at different levels of GSH depletion are presented

  11. Oxygen tension level and human viral infections

    Energy Technology Data Exchange (ETDEWEB)

    Morinet, Frédéric, E-mail: frederic.morinet@sls.aphp.fr [Centre des Innovations Thérapeutiques en Oncologie et Hématologie (CITOH), CHU Saint-Louis, Paris (France); Université Denis Diderot, Sorbonne Paris Cité Paris, Paris (France); Casetti, Luana [Institut Cochin INSERM U1016, Paris (France); François, Jean-Hugues; Capron, Claude [Institut Cochin INSERM U1016, Paris (France); Laboratoire d' Hématologie, Hôpital Ambroise Paré, Boulogne (France); Université de Versailles Saint-Quentin en Yvelynes, Versailles (France); Pillet, Sylvie [Laboratoire de Bactériologie-Virologie-Hygiène, CHU de Saint-Etienne, Saint-Etienne (France); Université de Lyon et Université de Saint-Etienne, Jean Monnet, GIMAP EA3064, F-42023 Saint-Etienne, Lyon (France)

    2013-09-15

    The role of oxygen tension level is a well-known phenomenon that has been studied in oncology and radiotherapy since about 60 years. Oxygen tension may inhibit or stimulate propagation of viruses in vitro as well as in vivo. In turn modulating oxygen metabolism may constitute a novel approach to treat viral infections as an adjuvant therapy. The major transcription factor which regulates oxygen tension level is hypoxia-inducible factor-1 alpha (HIF-1α). Down-regulating the expression of HIF-1α is a possible method in the treatment of chronic viral infection such as human immunodeficiency virus infection, chronic hepatitis B and C viral infections and Kaposi sarcoma in addition to classic chemotherapy. The aim of this review is to supply an updating concerning the influence of oxygen tension level in human viral infections and to evoke possible new therapeutic strategies regarding this environmental condition. - Highlights: • Oxygen tension level regulates viral replication in vitro and possibly in vivo. • Hypoxia-inducible factor 1 (HIF-1α) is the principal factor involved in Oxygen tension level. • HIF-1α upregulates gene expression for example of HIV, JC and Kaposi sarcoma viruses. • In addition to classical chemotherapy inhibition of HIF-1α may constitute a new track to treat human viral infections.

  12. IRMM low level underground laboratory in HADES

    Energy Technology Data Exchange (ETDEWEB)

    Mouchel, D [CEC-JRC, Inst. for Reference Materials and Measurements (IRMM), Geel (Belgium); Wordel, R [CEC-JRC, Inst. for Reference Materials and Measurements (IRMM), Geel (Belgium)

    1997-03-01

    The operation of low background HPGe detectors at a depth of 225 m, reduced the background by two orders of magnitude; a large amount of the remaining background is still attributable to the cosmic rays. The selection of radiopure materials, the characterization of reference matrices and the measurements of low radioactivities in environmental samples are performed. Coupling the low level spectrometry with additional techniques, e.g. neutron activation, will allow to measure extremely low radioactivities. (orig.)

  13. Toxic effects of low doses of Bisphenol-A on human placental cells

    International Nuclear Information System (INIS)

    Benachour, Nora; Aris, Aziz

    2009-01-01

    Humans are exposed daily to a great number of xenobiotics and their metabolites present as pollutants. Bisphenol-A (BPA) is extensively used in a broad range of products including baby bottles, food-storage containers, medical equipment, and consumer electronics. Thus, BPA is the most common monomer for polycarbonates intended for food contact. Levels of this industrial product are found in maternal blood, amniotic fluid, follicular fluid, placental tissue, umbilical cord blood, and maternal urine. In this study, we investigated toxic effects of BPA concentrations close to levels found in serum of pregnant women on human cytotrophoblasts (CTB). These cells were isolated from fresh placentas and exposed to BPA for 24 h. Our results showed that very low doses of BPA induce apoptosis (2 to 3 times) as assessed using M30 antibody immunofluorescent detection, and necrosis (1.3 to 1.7 times) as assessed through the cytosolic Adenylate Kinase (AK) activity after cell membrane damage. We also showed that BPA increased significantly the tumor-necrosis factor alpha (TNF-α) gene expression and protein excretion as measured by real-time RT-PCR and ELISA luminescent test, respectively. Moreover, we observed that induction of AK activation and TNF-α gene expression require lower levels of BPA than apoptosis or TNF-α protein excretion. Our findings suggest that exposure of placental cells to low doses of BPA may cause detrimental effects, leading in vivo to adverse pregnancy outcomes such as preeclampsia, intrauterine growth restriction, prematurity and pregnancy loss.

  14. Modified physiologically equivalent temperature—basics and applications for western European climate

    Science.gov (United States)

    Chen, Yung-Chang; Matzarakis, Andreas

    2018-05-01

    A new thermal index, the modified physiologically equivalent temperature (mPET) has been developed for universal application in different climate zones. The mPET has been improved against the weaknesses of the original physiologically equivalent temperature (PET) by enhancing evaluation of the humidity and clothing variability. The principles of mPET and differences between original PET and mPET are introduced and discussed in this study. Furthermore, this study has also evidenced the usability of mPET with climatic data in Freiburg, which is located in Western Europe. Comparisons of PET, mPET, and Universal Thermal Climate Index (UTCI) have shown that mPET gives a more realistic estimation of human thermal sensation than the other two thermal indices (PET, UTCI) for the thermal conditions in Freiburg. Additionally, a comparison of physiological parameters between mPET model and PET model (Munich Energy Balance Model for Individual, namely MEMI) is proposed. The core temperatures and skin temperatures of PET model vary more violently to a low temperature during cold stress than the mPET model. It can be regarded as that the mPET model gives a more realistic core temperature and mean skin temperature than the PET model. Statistical regression analysis of mPET based on the air temperature, mean radiant temperature, vapor pressure, and wind speed has been carried out. The R square (0.995) has shown a well co-relationship between human biometeorological factors and mPET. The regression coefficient of each factor represents the influence of the each factor on changing mPET (i.e., ±1 °C of T a = ± 0.54 °C of mPET). The first-order regression has been considered predicting a more realistic estimation of mPET at Freiburg during 2003 than the other higher order regression model, because the predicted mPET from the first-order regression has less difference from mPET calculated from measurement data. Statistic tests recognize that mPET can effectively evaluate the

  15. Low-level radioactive waste disposal facility closure

    International Nuclear Information System (INIS)

    White, G.J.; Ferns, T.W.; Otis, M.D.; Marts, S.T.; DeHaan, M.S.; Schwaller, R.G.; White, G.J.

    1990-11-01

    Part I of this report describes and evaluates potential impacts associated with changes in environmental conditions on a low-level radioactive waste disposal site over a long period of time. Ecological processes are discussed and baselines are established consistent with their potential for causing a significant impact to low-level radioactive waste facility. A variety of factors that might disrupt or act on long-term predictions are evaluated including biological, chemical, and physical phenomena of both natural and anthropogenic origin. These factors are then applied to six existing, yet very different, low-level radioactive waste sites. A summary and recommendations for future site characterization and monitoring activities is given for application to potential and existing sites. Part II of this report contains guidance on the design and implementation of a performance monitoring program for low-level radioactive waste disposal facilities. A monitoring programs is described that will assess whether engineered barriers surrounding the waste are effectively isolating the waste and will continue to isolate the waste by remaining structurally stable. Monitoring techniques and instruments are discussed relative to their ability to measure (a) parameters directly related to water movement though engineered barriers, (b) parameters directly related to the structural stability of engineered barriers, and (c) parameters that characterize external or internal conditions that may cause physical changes leading to enhanced water movement or compromises in stability. Data interpretation leading to decisions concerning facility closure is discussed. 120 refs., 12 figs., 17 tabs

  16. Low-level radioactive waste disposal facility closure

    Energy Technology Data Exchange (ETDEWEB)

    White, G.J.; Ferns, T.W.; Otis, M.D.; Marts, S.T.; DeHaan, M.S.; Schwaller, R.G.; White, G.J. (EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1990-11-01

    Part I of this report describes and evaluates potential impacts associated with changes in environmental conditions on a low-level radioactive waste disposal site over a long period of time. Ecological processes are discussed and baselines are established consistent with their potential for causing a significant impact to low-level radioactive waste facility. A variety of factors that might disrupt or act on long-term predictions are evaluated including biological, chemical, and physical phenomena of both natural and anthropogenic origin. These factors are then applied to six existing, yet very different, low-level radioactive waste sites. A summary and recommendations for future site characterization and monitoring activities is given for application to potential and existing sites. Part II of this report contains guidance on the design and implementation of a performance monitoring program for low-level radioactive waste disposal facilities. A monitoring programs is described that will assess whether engineered barriers surrounding the waste are effectively isolating the waste and will continue to isolate the waste by remaining structurally stable. Monitoring techniques and instruments are discussed relative to their ability to measure (a) parameters directly related to water movement though engineered barriers, (b) parameters directly related to the structural stability of engineered barriers, and (c) parameters that characterize external or internal conditions that may cause physical changes leading to enhanced water movement or compromises in stability. Data interpretation leading to decisions concerning facility closure is discussed. 120 refs., 12 figs., 17 tabs.

  17. Low-level laser therapy: Effects on human face aged skin and cell viability of HeLa cells exposed to UV radiation

    Directory of Open Access Journals (Sweden)

    Mezghani Sana

    2015-01-01

    Full Text Available Chronic and excessive exposure to UV radiation leads to photoaging and photocarcinogenesis. Adequate protection of the skin against the deleterious effects of UV irradiation is essential. Low-level laser therapy (LLLT is a light source in the red to near-infrared range that has been accepted in a variety of medical applications. In this study, we explored the effect of LLLT in human face aged skin and the cell viability of HeLa cells exposed to UV radiation. We found that LLLT significantly reduced visible wrinkles and the loss of firmness of facial skin in aging subjects. Additionally, treatment of cultured HeLa cells with LLLT prior to or post UVA or UVB exposure significantly protected cells from UV-mediated cell death. All results showed the beneficial effects of LLLT on relieving signs of skin aging and its prevention and protection of the cell viability against UV-induced damage.

  18. Potential impact of DOE's performance objective for protection of inadvertent intruders on low-level waste disposals at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1992-01-01

    The Department of Energy's Order 5820.2A, Chapter III, specifies performance objectives for disposal of low-level radioactive waste which include limits on effective dose equivalent for inadvertent intruders. This paper investigates the potential impact of the performance objective for protection of inadvertent intruders on the acceptability of waste disposals in Solid Waste Storage Area (SWSA) 6 at Oak Ridge National Laboratory (ORNL). The analysis is based on radionuclide inventories and waste volumes for recent disposals in SWSA 6 and calculated doses to an inadvertent intruder per unit concentration of radionuclides in disposed waste for assumed exposure scenarios

  19. Twelfth annual US DOE low-level waste management conference

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The papers in this document comprise the proceedings of the Department of Energy's Twelfth Annual Low-Level Radioactive Waste Management Conference, which was held in Chicago, Illinois, on August 28 and 29, 1990. General subjects addressed during the conference included: mixed waste, low-level radioactive waste tracking and transportation, public involvement, performance assessment, waste stabilization, financial assurance, waste minimization, licensing and environmental documentation, below-regulatory-concern waste, low-level radioactive waste temporary storage, current challenges, and challenges beyond 1990.

  20. Radiobiologic effects at low radiation levels

    International Nuclear Information System (INIS)

    Casarett, G.W.

    1975-01-01

    Data are reviewed on the effects of low radiation doses on mammals. Data from the 1972 report on the Biological Effects of Ionizing Radiation issued by the Advisory Committee of the National Academy of Sciences and National Research Council are discussed. It was concluded that there are certain radiosensitive systems in which low doses of radiation may cause degenerative effects, including gametogenic epithelium, lens of the eye, and developing embryos. Despite extensive investigation of genetic effects, including chromosomal effects, neither the amount of change that will be caused by very low levels of irradiation nor the degree of associated detriment is known

  1. Three-nucleon problem with phase equivalent potentials

    International Nuclear Information System (INIS)

    Pushkash, O.M.; Shapoval, D.V.; Simenog, I.V.

    1991-01-01

    The effect of the t-matrix off-shell variations with nonlocal phase equivalent N-N potentials on the three-nucleon parameters is studied. The variations, which lower or increase the tritium binding energy, are revealed. We show that under certain conditions, the three-nucleon low-energy observables are almost insensitive to the high energy behaviour of the negative parts of the scattering phase shifts. The inverse problem method is applied to reconstruct simple S-wave potentials which to provide a unified description of the two-nucleon and low-energy three-nucleon data. 22 refs.; 6 figs. (author)

  2. Correlates of protection against human rotavirus disease and the factors influencing protection in low-income settings.

    Science.gov (United States)

    Clarke, E; Desselberger, U

    2015-01-01

    Rotaviruses (RV) are the leading cause of gastroenteritis in infants and children worldwide and are associated with high mortality predominately in low-income settings. The virus is classified into G and P serotypes and further into P genotypes based on differences in the surface-exposed proteins VP7 and VP4, respectively. Infection results in a variable level of protection from subsequent reinfection and disease. This protection is predominantly homotypic in some settings, whereas broader heterotypic protection is reported in other cohorts. Two antigenically distinct oral RV vaccines are licensed and are being rolled out widely, including in resource-poor setting, with funding provided by the GAVI alliance. First is a monovalent vaccine derived from a live-attenuated human RV strain, whereas the second is a pentavalent bovine-human reassortment vaccine. Both vaccines are highly efficacious in high-income settings, but greatly reduced levels of protection are reported in low-income countries. Here, the current challenges facing mucosal immunologists and vaccinologists aiming to define immunological correlates and to understand the variable levels of protection conferred by these vaccines in humans is considered. Such understanding is critical to maximize the public health impact of the current vaccines and also to the development of the next generation of RV vaccines, which are needed.

  3. Low-level waste forum meeting reports

    International Nuclear Information System (INIS)

    Sternwheeler, W.D.E.

    1992-01-01

    This paper provides highlights from the 1992 winter meeting of the Low Level Radioactive Wastes Forum. Topics of discussion included: legal information; state and compact reports; freedom of information requests; and storage

  4. Low-level waste forum meeting reports

    International Nuclear Information System (INIS)

    1992-01-01

    This paper provides highlights from the summer meeting of the Low Level Radioactive Waste Forum. Topics of discussion included: responsibility for nonfuel component disposal; state experiences in facility licensing; and volume projections

  5. Low-level nuclear waste in Washington State

    International Nuclear Information System (INIS)

    Williams, H.

    1986-01-01

    A commercial disposal site for low-level nuclear wastes opened at Hanford in 1965. By 1971 a total of six were in operation: Hanford, Nevada, South Carolina, Kentucky, New York State, and Illinois. The history of the operation of these sites is described. Only the first three listed are still open. The effects of the large volumes of waste expected from Three Mile Island are described. This paper examines the case history of Hanford operations with low-level waste disposal for lessons that might apply in other states being considered for disposal sites

  6. Intermittent, low dose carbon monoxide exposure enhances survival and dopaminergic differentiation of human neural stem cells

    DEFF Research Database (Denmark)

    Dreyer-Andersen, Nanna; Almeida, Ana Sofia; Jensen, Pia

    2018-01-01

    Exploratory studies using human fetal tissue have suggested that intrastriatal transplantation of dopaminergic neurons may become a future treatment for patients with Parkinson's disease. However, the use of human fetal tissue is compromised by ethical, regulatory and practical concerns. Human stem...... cells constitute an alternative source of cells for transplantation in Parkinson's disease, but efficient protocols for controlled dopaminergic differentiation need to be developed. Short-term, low-level carbon monoxide (CO) exposure has been shown to affect signaling in several tissues, resulting...... in Parkinson's disease....

  7. Applications Geiger-Muller detectors monitor the level of radioactivity in the human body

    International Nuclear Information System (INIS)

    Gunarwan Prayitno

    2008-01-01

    Nuclear technology is the technology high risk, because of an application and implementation have to support by human skill. The support facility has to complete and up to date, or modern. It means if the accident occurs in mistake have to do or delayed something, they can solved that problem. So the probability the risk of accident can be minimized. The specific problem is in the implementation nuclear technology on the human safety which is works in the radiation field or in the environment where they are working. The pointer that the problems have to design the tools monitor to monitoring the value radiation maximum was allowed. The tools monitor design is giving the information signal, if the radiation level maximum have over limit. Whereas the high and low level radiation can be just depend on the needed. (author)

  8. Low-level radioactive waste disposal in the United States

    International Nuclear Information System (INIS)

    Ozaki, Calvin B.; Kerr, Thomas A.; Williams, R. Eric

    1991-01-01

    Two national systems comprise the low-level radioactive waste management system in the United States of America. The U.S. Nuclear Regulatory Commission regulates low-level radioactive waste produced in the public sector (commercial waste), and the U.S. Department of Energy manages low-level radioactive waste produced by government-sponsored programs. The primary distinction between the two national systems is the source of regulatory control. This paper discusses two issues critical to the success of each system: the site selection process used by the commercial low-level waste disposal system, and the evaluation process used to determine configuration of the DOE waste management system. The two national systems take different approaches to reach the same goals, which are increased social responsibility, protection of public health and safety, and protection of the environment

  9. Vitamin A levels and human immunodeficiency virus load in injection drug users.

    Science.gov (United States)

    Semba, R D; Farzadegan, H; Vlahov, D

    1997-01-01

    Although low plasma vitamin A levels are associated with increased mortality and higher vertical transmission during human immunodeficiency virus (HIV) infection, it is unknown whether plasma low vitamin A levels are a marker for circulating HIV load. We conducted a cross-sectional study within a prospective cohort study of injection drug users in order to evaluate the relationship between plasma vitamin A levels and HIV viral load. Plasma vitamin A level was measured by high-performance liquid chromatography. Infectious viral load was measured by quantitative microculture of serial fivefold dilutions of 10(6) peripheral blood mononuclear cells. A total of 284 HIV-infected adults (79 women, 205 men) were studied. Plasma vitamin A levels consistent with deficiency were found in 28.9% of adults. A total of 38.0% of women and 25.3% of men had vitamin A deficiency (P < 0.04). The median infectious viral load for the entire study population was 8 infectious units per million cells. No significant relationship between plasma vitamin A levels and infectious viral load was observed in these injection drug users. This study suggests that there is no correlation between HIV viral load and plasma vitamin A levels in injection drug users, and these variables may represent independent risk factors during HIV infection. HIV-infected adult women appear to be at higher risk of developing vitamin A deficiency. PMID:9008289

  10. Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation

    International Nuclear Information System (INIS)

    Finnerty, M.; Brennan, P.C.

    2005-01-01

    The composition of protective aprons worn by X-ray personnel to shield against secondary radiation is changing. Lead is being replaced by either lead-free or composite (lead with other high atomic numbered elements) materials. These newer aprons are categorised by manufacturers in terms of lead equivalent values, but it is unclear how these stated values compare with actual lead equivalent values. In this work, the actual lead equivalence of 41 protective aprons from four manufacturers, all specified as having 0.25 mm lead equivalence, were investigated with transmission experiments at 70 and 100 kVp. All aprons were in current use. The aprons were screened for defects, and age, weight and design was recorded along with details of associated quality assurance (QA). Out of the 41 protective aprons examined for actual lead equivalence, 73% were outside tolerance levels, with actual levels in some aprons demonstrating less than half of the nominal values. The lack of compatibility between actual and nominal lead equivalent values was demonstrated by aprons from three of the four manufacturers investigated. The area of the defects found on screening of the protective aprons were within recommendations. The results highlight the need for acceptancy and ongoing checks of protective aprons to ensure that radiation exposure of imaging personnel is kept to a minimum. (orig.)

  11. Availability verification of information for human system interface in automatic SG level control using activity diagram

    Energy Technology Data Exchange (ETDEWEB)

    Nuraslinda, Anuar; Kim, Dong Young; Kim, Jong Hyun [KEPCO International Nuclear Graduate School, Uljugun (Korea, Republic of)

    2012-10-15

    Steam Generator (SG) level control system in OPR 1000 is one of representative automatic systems that falls under the Supervisory Control level in Endsley's taxonomy. Supervisory control of automated systems is classified as a form of out of the loop (OOTL) performance due to passive involvement in the systems operation, which could lead to loss of situation awareness (SA). There was a reported event, which was caused by inadequate human automation communication that contributed to an unexpected reactor trip in July 2005. A high SG level trip occurred in Yeonggwang (YGN) Unit 6 Nuclear Power Plant (NPP) due to human operator failure to recognize the need to change the control mode of the economizer valve controller (EVC) to manual mode during swap over (the transition from low power mode to high power mode) after the loss of offsite power (LOOP) event was recovered. This paper models the human system interaction in NPP SG level control system using Unified Modeling Language (UML) Activity Diagram. Then, it identifies the missing information for operators in the OPR1000 Main Control Room (MCR) and suggests some means of improving the human system interaction.

  12. Availability verification of information for human system interface in automatic SG level control using activity diagram

    International Nuclear Information System (INIS)

    Nuraslinda, Anuar; Kim, Dong Young; Kim, Jong Hyun

    2012-01-01

    Steam Generator (SG) level control system in OPR 1000 is one of representative automatic systems that falls under the Supervisory Control level in Endsley's taxonomy. Supervisory control of automated systems is classified as a form of out of the loop (OOTL) performance due to passive involvement in the systems operation, which could lead to loss of situation awareness (SA). There was a reported event, which was caused by inadequate human automation communication that contributed to an unexpected reactor trip in July 2005. A high SG level trip occurred in Yeonggwang (YGN) Unit 6 Nuclear Power Plant (NPP) due to human operator failure to recognize the need to change the control mode of the economizer valve controller (EVC) to manual mode during swap over (the transition from low power mode to high power mode) after the loss of offsite power (LOOP) event was recovered. This paper models the human system interaction in NPP SG level control system using Unified Modeling Language (UML) Activity Diagram. Then, it identifies the missing information for operators in the OPR1000 Main Control Room (MCR) and suggests some means of improving the human system interaction

  13. Quality factor and dose equivalent investigations aboard the Soviet Space Station Mir

    Science.gov (United States)

    Bouisset, P.; Nguyen, V. D.; Parmentier, N.; Akatov, Ia. A.; Arkhangel'Skii, V. V.; Vorozhtsov, A. S.; Petrov, V. M.; Kovalev, E. E.; Siegrist, M.

    1992-07-01

    Since Dec 1988, date of the French-Soviet joint space mission 'ARAGATZ', the CIRCE device, had recorded dose equivalent and quality factor values inside the Mir station (380-410 km, 51.5 deg). After the initial gas filling two years ago, the low pressure tissue equivalent proportional counter is still in good working conditions. Some results of three periods are presented. The average dose equivalent rates measured are respectively 0.6, 0.8 and 0.6 mSv/day with a quality factor equal to 1.9. Some detailed measurements show the increasing of the dose equivalent rates through the SAA and near polar horns. The real time determination of the quality factors allows to point out high linear energy transfer events with quality factors in the range 10-20.

  14. Correspondences. Equivalence relations

    International Nuclear Information System (INIS)

    Bouligand, G.M.

    1978-03-01

    We comment on sections paragraph 3 'Correspondences' and paragraph 6 'Equivalence Relations' in chapter II of 'Elements de mathematique' by N. Bourbaki in order to simplify their comprehension. Paragraph 3 exposes the ideas of a graph, correspondence and map or of function, and their composition laws. We draw attention to the following points: 1) Adopting the convention of writting from left to right, the composition law for two correspondences (A,F,B), (U,G,V) of graphs F, G is written in full generality (A,F,B)o(U,G,V) = (A,FoG,V). It is not therefore assumed that the co-domain B of the first correspondence is identical to the domain U of the second (EII.13 D.7), (1970). 2) The axiom of choice consists of creating the Hilbert terms from the only relations admitting a graph. 3) The statement of the existence theorem of a function h such that f = goh, where f and g are two given maps having the same domain (of definition), is completed if h is more precisely an injection. Paragraph 6 considers the generalisation of equality: First, by 'the equivalence relation associated with a map f of a set E identical to (x is a member of the set E and y is a member of the set E and x:f = y:f). Consequently, every relation R(x,y) which is equivalent to this is an equivalence relation in E (symmetrical, transitive, reflexive); then R admits a graph included in E x E, etc. Secondly, by means of the Hilbert term of a relation R submitted to the equivalence. In this last case, if R(x,y) is separately collectivizing in x and y, theta(x) is not the class of objects equivalent to x for R (EII.47.9), (1970). The interest of bringing together these two subjects, apart from this logical order, resides also in the fact that the theorem mentioned in 3) can be expressed by means of the equivalence relations associated with the functions f and g. The solutions of the examples proposed reveal their simplicity [fr

  15. Low dose human calcium assay in vivo via the 40Ca(n,α) reaction

    International Nuclear Information System (INIS)

    Bigler, R.E.; Laughlin, J.S.; Davis, R. Jr.; Evans, J.C.

    1974-01-01

    A compact medical cyclotron was investigated to elucidate its merit as a neutron source for both qualitative and quantitative activation analysis human studies in vivo of calcium and other elements within the human body and at reasonable radiation dose levels. Emphasis is given to those properties necessary for carrying out quantitative whole body calcium measurements using the 40 (n,α) 37 Ar reaction, which because of the low radiation dose and relatively modest equipment requirements, give this method potential for wide application in diagnostic studies of calcium metabolism. (U.S.)

  16. Low dose human calcium assay in vivo via the 40Ca(n,α) reaction

    International Nuclear Information System (INIS)

    Bigler, R.E.; Davis, R. Jr.; Evans, J.C.

    1974-01-01

    A compact medical cyclotron has been investigated to elucidate its merit as a neutron source for both qualitative and quantitative activation analysis human studies in vivo of calcium and other elements within the human body and at reasonable radiation dose levels. Emphasis is given to those properties necessary for carrying out quantitative whole body calcium measurements using the 40 Ca(n, α) 37 Ar reaction, which because of the low radiation dose and relatively modest equipment requirements, give this method potential for wide application in diagnostic studies of calcium metabolism

  17. On equivalent resistance of electrical circuits

    Science.gov (United States)

    Kagan, Mikhail

    2015-01-01

    While the standard (introductory physics) way of computing the equivalent resistance of nontrivial electrical circuits is based on Kirchhoff's rules, there is a mathematically and conceptually simpler approach, called the method of nodal potentials, whose basic variables are the values of the electric potential at the circuit's nodes. In this paper, we review the method of nodal potentials and illustrate it using the Wheatstone bridge as an example. We then derive a closed-form expression for the equivalent resistance of a generic circuit, which we apply to a few sample circuits. The result unveils a curious interplay between electrical circuits, matrix algebra, and graph theory and its applications to computer science. The paper is written at a level accessible by undergraduate students who are familiar with matrix arithmetic. Additional proofs and technical details are provided in appendices.

  18. A review of low-level air pollution and adverse effects on human health: implications for epidemiological studies and public policy

    Science.gov (United States)

    Olmo, Neide Regina Simões; do Nascimento Saldiva, Paulo Hilário; Braga, Alfésio Luís Ferreira; Lin, Chin An; de Paula Santos, Ubiratan; Pereira, Luiz Alberto Amador

    2011-01-01

    The aim of this study was to review original scientific articles describing the relationship between atmospheric pollution and damage to human health. We also aimed to determine which of these studies mentioned public policy issues. Original articles relating to atmospheric pollution and human health published between 1995 and 2009 were retrieved from the PubMed database and analyzed. This study included only articles dealing with atmospheric pollutants resulting primarily from vehicle emissions. Three researchers were involved in the final selection of the studies, and the chosen articles were approved by at least two of the three researchers. Of the 84 non-Brazilian studies analyzed, 80 showed an association between atmospheric pollution and adverse effects on human health. Moreover, 66 showed evidence of adverse effects on human health, even at levels below the permitted emission standards. Three studies mentioned public policies aimed at changing emission standards. Similarly, the 29 selected Brazilian studies reported adverse associations with human health, and 27 showed evidence of adverse effects even at levels below the legally permitted emission standards. Of these studies, 16 mentioned public policies aimed at changing emission standards. Based on the Brazilian and non-Brazilian scientific studies that have been conducted, it can be concluded that, even under conditions that are compliant with Brazilian air quality standards, the concentration of atmospheric pollutants in Brazil can negatively affect human health. However, as little discussion of this topic has been generated, this finding demonstrates the need to incorporate epidemiological evidence into decisions regarding legal regulations and to discuss the public policy implications in epidemiological studies. PMID:21655765

  19. A product designed for final disposal of low and intermediate level radioactive wastes

    International Nuclear Information System (INIS)

    Baboescu, E.; Popescu, I. V.

    2001-01-01

    The product 'metallic barrel - concrete - low level radioactive wastes - 1' (ABBD - 1) was certified according to the company's standard SF ICN/1994, updated 1. The product ABBD -1 is produced according to the following certified technologies: - technology for processing and conditioning of low level radioactive solid wastes; - technology for processing and conditioning of waste ion exchangers from the TRIGA reactor; - technology for conditioning the β - γ radioactive compacts. The product is constituted of a protection shield, the concrete block - radioactive waste, securing high mechanical strength and a high degree of radionuclides retaining, thus ensuring the necessary condition for long time disposal and, finally, the metallic container fulfilling the National Standards of Nuclear Safety for Radioactive Materials Transportation. The metallic container is made of pickled slab, with a 220 l capacity, according to STAS 7683/88 standards. The main characteristics of the product 'ABBD - 1' are: - size: height, 915 ± 10 mm, diameter, 600 ± 5 mm; - mass, 300 - 600 kg; - maximum permissible activity, 6 x 10 9 Bq/ barrel (0.164 Ci/barrel); - equivalent dose rate for gamma radiation at barrel's wall, max. 1 mSv/h (200 mrem/h); - unfixed external contamination, 2 ; - compression strength of concrete block alone, > 5 x 10 6 N/m 2 ; - lixiviation rate, -3 cm/day; - the compact concrete block-radioactive waste is leak-proof and crack-free. The final product is transferred from INR Pitesti to National Repository for Radioactive Waste by railway and road transportation according to the provisions of the National Commission for Nuclear Activity Control as stipulated in the National Standards of Nuclear Safety of Radioactive Materials Transportation

  20. Low-frequency, low-magnitude vibrations (LFLM enhances chondrogenic differentiation potential of human adipose derived mesenchymal stromal stem cells (hASCs

    Directory of Open Access Journals (Sweden)

    Krzysztof Marycz

    2016-02-01

    Full Text Available The aim of this study was to evaluate if low-frequency, low-magnitude vibrations (LFLM could enhance chondrogenic differentiation potential of human adipose derived mesenchymal stem cells (hASCs with simultaneous inhibition of their adipogenic properties for biomedical purposes. We developed a prototype device that induces low-magnitude (0.3 g low-frequency vibrations with the following frequencies: 25, 35 and 45 Hz. Afterwards, we used human adipose derived mesenchymal stem cell (hASCS, to investigate their cellular response to the mechanical signals. We have also evaluated hASCs morphological and proliferative activity changes in response to each frequency. Induction of chondrogenesis in hASCs, under the influence of a 35 Hz signal leads to most effective and stable cartilaginous tissue formation through highest secretion of Bone Morphogenetic Protein 2 (BMP-2, and Collagen type II, with low concentration of Collagen type I. These results correlated well with appropriate gene expression level. Simultaneously, we observed significant up-regulation of α3, α4, β1 and β3 integrins in chondroblast progenitor cells treated with 35 Hz vibrations, as well as Sox-9. Interestingly, we noticed that application of 35 Hz frequencies significantly inhibited adipogenesis of hASCs. The obtained results suggest that application of LFLM vibrations together with stem cell therapy might be a promising tool in cartilage regeneration.

  1. Conditions for equivalence of statistical ensembles in nuclear multifragmentation

    International Nuclear Information System (INIS)

    Mallik, Swagata; Chaudhuri, Gargi

    2012-01-01

    Statistical models based on canonical and grand canonical ensembles are extensively used to study intermediate energy heavy-ion collisions. The underlying physical assumption behind canonical and grand canonical models is fundamentally different, and in principle agree only in the thermodynamical limit when the number of particles become infinite. Nevertheless, we show that these models are equivalent in the sense that they predict similar results if certain conditions are met even for finite nuclei. In particular, the results converge when nuclear multifragmentation leads to the formation of predominantly nucleons and low mass clusters. The conditions under which the equivalence holds are amenable to present day experiments.

  2. Low-level waste disposal performance assessments - Total source-term analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wilhite, E.L.

    1995-12-31

    Disposal of low-level radioactive waste at Department of Energy (DOE) facilities is regulated by DOE. DOE Order 5820.2A establishes policies, guidelines, and minimum requirements for managing radioactive waste. Requirements for disposal of low-level waste emplaced after September 1988 include providing reasonable assurance of meeting stated performance objectives by completing a radiological performance assessment. Recently, the Defense Nuclear Facilities Safety Board issued Recommendation 94-2, {open_quotes}Conformance with Safety Standards at Department of Energy Low-Level Nuclear Waste and Disposal Sites.{close_quotes} One of the elements of the recommendation is that low-level waste performance assessments do not include the entire source term because low-level waste emplaced prior to September 1988, as well as other DOE sources of radioactivity in the ground, are excluded. DOE has developed and issued guidance for preliminary assessments of the impact of including the total source term in performance assessments. This paper will present issues resulting from the inclusion of all DOE sources of radioactivity in performance assessments of low-level waste disposal facilities.

  3. Health effects of low-level ionizing radiation

    International Nuclear Information System (INIS)

    Fabrikant, J.I.

    1979-04-01

    It is now assumed that any exposure to radiaton at low levels of dose carries some risk of deleterious effects. How low this level may be, or the probability or magnitude of the risk, still are not known. Our best scientific knowledge and advice are essential for the protection of the public health, for the effective application of new technologies in medicine and industry and for guidance in the production of nuclear energy. Unless man wishes to dispense with those activities which inevitably involve exposure to low levels of ionizing radiations, he must recognize that some degree of risk to health, however small, exists. A pragmatic appraisal of how man wishes to continue to derive the benefits of health and happiness from such activities involving ionizing radiaton in times of everchanging conditions and public attitudes in our resource-limited society is the task which lies before all of us - all men and women of our society, of science and of medicine, and of law and government - now and in the future

  4. LOWRAD 96. Methods and applications of low-level radioactivity measurements. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Fietz, J [ed.; Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    1997-03-01

    The newest developments in the field of low-level radioactivity measurements and new applications for existing and low-level measuring facilities are presented. The contributions mostly were devoted to basic physical aspects and applications of low-level counting. Papers on chemical separation and preparation techniques and on low-level radiation dose determinations were also presented. (DG)

  5. A sensitivity study of an evaluation of alternatives for disposal of INEL low-level waste and low-level mixed waste

    International Nuclear Information System (INIS)

    Roesener, W.S.; Smith, T.H.; Jorgenson-Waters, M.J.; Sherick, M.J.

    1995-01-01

    This paper presents insights gained from an informal sensitivity study of an evaluation of disposal alternatives for Idaho National Engineering Laboratory low-level waste and low-level mixed waste. The insights relate to the sensitivity of the alternative rankings to changes in assumptions identified as open-quotes key uncertaintiesclose quotes. The result of the sensitivity study is that significant changes occur in the rankings when selected open-quotes key uncertaintiesclose quotes are varied over reasonable ranges. Three alternatives involving the use of (a) shallow land burial and boreholes or (b) greater-depth burial and boreholes rank high for all cases investigated. The other alternatives rank low in some or all cases

  6. Human Capital Externalities : Effects for Low-Educated Workers and Low-Skilled Jobs

    NARCIS (Netherlands)

    Broersma, Lourens; Edzes, Arjen J. E.; Van Dijk, Jouke

    2016-01-01

    Investments in human capital are essential themes in many policy programmes. Besides the direct private returns of education, there is evidence of positive human capital externalities at the level of regions and firms. The results in this paper show that both production and consumption externalities

  7. The impact of low and intermediate-level radioactive waste on humans and the environment over the next one hundred thousand years

    International Nuclear Information System (INIS)

    Kautsky, Ulrik; Saetre, Peter; Berglund, Sten; Jaeschke, Ben; Nordén, Sara; Brandefelt, Jenny; Keesmann, Sven; Näslund, Jens-Ove; Andersson, Eva

    2016-01-01

    In order to assess the potential radiological risk to humans and the environment from a geological repository for radioactive waste, a safety assessment must be performed. This implies that the release and transfer of radionuclides from the repository into the surface environment are calculated and that the effects in the biosphere are evaluated for an assessment period up to one hundred thousand years according to Swedish regulations. This paper discusses the challenges associated with the modelling of surface ecosystems over such long time scales, using the recently completed assessment for the extension of the existing repository for the low- and intermediate-level nuclear waste (called SFR) in Forsmark, Sweden as an applied example. In the assessment, natural variation and uncertainties in climate during the assessment period were captured by using a set of climate cases, primarily reflecting different expectations on the effects of global warming. Development of the landscape at the site, due to post-glacial isostatic rebound, was modelled, and areas where modelling indicated that radionuclides could discharge into the biosphere were identified. Transfers of surface water and groundwater were described with spatially distributed hydrological models. The projected release of radionuclides from the bedrock was then fed into a biosphere radionuclide transport model, simulating the transport and fate of radionuclides within and between ecosystems in the landscape. Annual doses for human inhabitants were calculated by combining activity concentrations in environmental media (soil, water, air and plants) with assumptions on habits and land-use of future human inhabitants. Similarly, dose rates to representative organisms of non-human biota were calculated from activity concentrations in relevant habitats, following the ERICA methodology. In the main scenario, the calculated risk for humans did not exceed the risk criteria or the screening dose rate for non-human

  8. 1989 state-by-state assessment of low-level radioactive wastes received at commercial disposal sites: National Low-Level Waste Management Program

    International Nuclear Information System (INIS)

    Fuchs, R.L.; Culbertson-Arendts, K.

    1990-12-01

    The National Low-Level Waste Management Program has published eleven annual state-by-state assessment reports. These reports provide both national and state-specific disposal data on low-level radioactive wastes. Data in this report are divided into generator category, waste class, volume, and activity. Included in this report are tables showing a distribution of wastes by state for 1989 and a comparison of waste volumes by state for 1985 through 1989; also included is a list of all commercial nuclear power reactors in the United States as of December 31, 1989. In this year's report, a distinction has been made between low-level radioactive waste shipped directly for disposal by generators and that handled by an intermediary. 7 refs., 4 tabs

  9. Treatment of uncertainty in low-level waste performance assessment

    International Nuclear Information System (INIS)

    Kozak, M.W.; Olague, N.E.; Gallegos, D.P.; Rao, R.R.

    1991-01-01

    Uncertainties arise from a number of different sources in low-level waste performance assessment. In this paper the types of uncertainty are reviewed, and existing methods for quantifying and reducing each type of uncertainty are discussed. These approaches are examined in the context of the current low-level radioactive waste regulatory performance objectives, which are deterministic. The types of uncertainty discussed in this paper are model uncertainty, uncertainty about future conditions, and parameter uncertainty. The advantages and disadvantages of available methods for addressing uncertainty in low-level waste performance assessment are presented. 25 refs

  10. Low-level light therapy potentiates NPe6-mediated photodynamic therapy in a human osteosarcoma cell line via increased ATP.

    Science.gov (United States)

    Tsai, Shang-Ru; Yin, Rui; Huang, Ying-Ying; Sheu, Bor-Ching; Lee, Si-Chen; Hamblin, Michael R

    2015-03-01

    Low-level light therapy (LLLT) is used to stimulate healing, reduce pain and inflammation, and preserve tissue from dying. LLLT has been shown to protect cells in culture from dying after various cytotoxic insults, and LLLT is known to increase the cellular ATP content. Previous studies have demonstrated that maintaining a sufficiently high ATP level is necessary for the efficient induction and execution of apoptosis steps after photodynamic therapy (PDT). We asked whether LLLT would protect cells from cytotoxicity due to PDT, or conversely whether LLLT would enhance the efficacy of PDT mediated by mono-l-aspartyl chlorin(e6) (NPe6). Increased ATP could lead to enhanced cell uptake of NPe6 by the energy dependent process of endocytosis, and also to more efficient apoptosis. In this study, human osteosarcoma cell line MG-63 was subjected to 1.5J/cm(2) of 810nm near infrared radiation (NIR) followed by addition of 10μM NPe6 and after 2h incubation by 1.5J/cm(2) of 652nm red light for PDT. PDT combined with LLLT led to higher cell death and increased intracellular reactive oxygen species compared to PDT alone. The uptake of NPe6 was moderately increased by LLLT, and cellular ATP was increased. The mitochondrial respiratory chain inhibitor antimycin A abrogated the LLLT-induced increase in cytotoxicity. Taken together, these results demonstrate that LLLT potentiates NPe6-mediated PDT via increased ATP synthesis and is a potentially promising strategy that could be applied in clinical PDT. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1987-11-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. Critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 [1] methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed. The effective dose equivalent determined using ICRP-26 methods is significantly smaller than the dose equivalent determined by traditional methods. No existing personnel dosimeter or health physics instrument can determine effective dose equivalent. At the present time, the conversion of dosimeter response to dose equivalent is based on calculations for maximal or ''cap'' values using homogeneous spherical or cylindrical phantoms. The evaluated dose equivalent is, therefore, a poor approximation of the effective dose equivalent as defined by ICRP Publication 26. 3 refs., 2 figs., 1 tab

  12. Equivalent threshold sound pressure levels (ETSPL) for Sennheiser HDA 280 supra-aural audiometric earphones in the frequency range 125 Hz to 8000 Hz

    DEFF Research Database (Denmark)

    Poulsen, Torben; Oakley, Sebastian

    2009-01-01

    Hearing threshold sound pressure levels were measured for the Sennheiser HDA 280 audiometric earphone. Hearing thresholds were measured for 25 normal hearing test subjects at the 11 audiometric test frequencies from 125 Hz to 8000 Hz. Sennheiser HDA 280 is a supra-aural earphone that may be seen...... as a substitute for the classical Telephonics TDH 39. The results are given as the Equivalent Threshold Sound Pressure Level, ETSPL, measured in an acoustic coupler specified in IEC 60318-3. The results are in good agreement with an independent investigation from PTB, Braunschweig, Germany. From acoustic...

  13. 'Omics analysis of low dose acetaminophen intake demonstrates novel response pathways in humans

    Energy Technology Data Exchange (ETDEWEB)

    Jetten, Marlon J.A.; Gaj, Stan [Department of Toxicogenomics, Maastricht University, Universitiessingel 50 6229 ER Maastricht (Netherlands); Ruiz-Aracama, Ainhoa [RIKILT, Institute of Food Safety, Wageningen UR, PO Box 230, 6700 AE, Wageningen (Netherlands); Kok, Theo M. de [Department of Toxicogenomics, Maastricht University, Universitiessingel 50 6229 ER Maastricht (Netherlands); Delft, Joost H.M. van, E-mail: j.vandelft@maastrichtuniversity.nl [Department of Toxicogenomics, Maastricht University, Universitiessingel 50 6229 ER Maastricht (Netherlands); Lommen, Arjen [RIKILT, Institute of Food Safety, Wageningen UR, PO Box 230, 6700 AE, Wageningen (Netherlands); Someren, Eugene P. van [Research Group Microbiology and Systems Biology, TNO, PO Box 360 3700 AJ Zeist (Netherlands); Jennen, Danyel G.J.; Claessen, Sandra M. [Department of Toxicogenomics, Maastricht University, Universitiessingel 50 6229 ER Maastricht (Netherlands); Peijnenburg, Ad A.C.M. [RIKILT, Institute of Food Safety, Wageningen UR, PO Box 230, 6700 AE, Wageningen (Netherlands); Stierum, Rob H. [Research Group Microbiology and Systems Biology, TNO, PO Box 360 3700 AJ Zeist (Netherlands); Kleinjans, Jos C.S. [Department of Toxicogenomics, Maastricht University, Universitiessingel 50 6229 ER Maastricht (Netherlands)

    2012-03-15

    Acetaminophen is the primary cause of acute liver toxicity in Europe/USA, which led the FDA to reconsider recommendations concerning safe acetaminophen dosage/use. Unfortunately, the current tests for liver toxicity are no ideal predictive markers for liver injury, i.e. they only measure acetaminophen exposure after profound liver toxicity has already occurred. Furthermore, these tests do not provide mechanistic information. Here, 'omics techniques (global analysis of metabolomic/gene-expression responses) may provide additional insight. To better understand acetaminophen-induced responses at low doses, we evaluated the effects of (sub-)therapeutic acetaminophen doses on metabolite formation and global gene-expression changes (including, for the first time, full-genome human miRNA expression changes) in blood/urine samples from healthy human volunteers. Many known and several new acetaminophen-metabolites were detected, in particular in relation to hepatotoxicity-linked, oxidative metabolism of acetaminophen. Transcriptomic changes indicated immune-modulating effects (2 g dose) and oxidative stress responses (4 g dose). For the first time, effects of acetaminophen on full-genome human miRNA expression have been considered and confirmed the findings on mRNA level. 'Omics techniques outperformed clinical chemistry tests and revealed novel response pathways to acetaminophen in humans. Although no definitive conclusion about potential immunotoxic effects of acetaminophen can be drawn from this study, there are clear indications that the immune system is triggered even after intake of low doses of acetaminophen. Also, oxidative stress-related gene responses, similar to those seen after high dose acetaminophen exposure, suggest the occurrence of possible pre-toxic effects of therapeutic acetaminophen doses. Possibly, these effects are related to dose-dependent increases in levels of hepatotoxicity-related metabolites. -- Highlights: ► 'Omics techniques

  14. Investigation of prostaglandin levels in human milk after high performance liquid chromatography purification

    International Nuclear Information System (INIS)

    Wu-Wang, C.Y.; Neu, J.

    1986-01-01

    This study was conducted to investigate five prostaglandins (PGs), i.e. PGE 2 , PGF/sub 2α/, 13-14-dihydro-15-keto-PGF/sub 2α/ (DHKF/sub 2α/), thromboxane B 2 (TXB 2 ) and 6-keto-PGF/sub 1α/), measured by (RIA) after C 18 Sep-Pak extraction and reverse phase high performance liquid chromatography (HPLC). Two trials were performed. In each trial, 3-5 mature human milk samples were pooled, acidified and extracted for PGs. The separation of PGs by HPLC was achieved by using an isocratic solvent system of acetonitrile/water (pH 3.0) (32/68, V/V). The PG levels from the two trials were determined and averaged after monitoring the recoveries. The results indicate that PGE 2 and DHKF/sub 2α/ are the two major PGs found in extracted human milk. However, after HPLC purification, no predominant PG is found and the levels of all the five PGs are much lower compared to the extracted sample. Since the immunoreactive material was also detected in HPLC fractions not within the PG peak, low levels of PG found in human milk after HPLC is likely due to the purification step removing the bulk of nonspecific immunoreactive substances present in the sample

  15. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  16. Cross-cultural measurement equivalence of the 5-level EQ-5D (EQ-5D-5L) in patients with type 2 diabetes mellitus in Singapore.

    Science.gov (United States)

    Wang, Ye; Tan, Ngiap-Chuan; Tay, Ee-Guan; Thumboo, Julian; Luo, Nan

    2015-07-16

    This study aimed to assess the measurement equivalence of the 5-level EQ-5D (EQ-5D-5L) among the English, Chinese, and Malay versions. A convenience sample of patients with type 2 diabetes mellitus were enrolled from a public primary health care institution in Singapore. The survey questionnaire comprised the EQ-5D-5L and questions assessing participants' socio-demographic and clinical characteristics. Multiple linear regression models were used to assess the difference in EQ-5D-5L index (calculated using an interim algorithm) and EQ-visual analog scale (EQ-VAS) scores across survey language (Chinese vs. English, Malay vs. English, and Malay vs. Chinese). Measurement equivalence was examined by comparing the 90% confidence interval of difference in the EQ-5D-5L index and EQ-VAS scores with a pre-determined equivalence margin. Multiple logistic regression models were used to assess the response patterns of the 5 Likert-type items of the EQ-5D-5L across survey language. Equivalence was demonstrated between the Chinese and English versions and between the Malay and English versions of the EQ-5D-5L index scores. Equivalence was also demonstrated between the Chinese and English versions and between the Malay and Chinese versions of the EQ-VAS scores. Equivalence could not be determined between the Malay and Chinese versions of the EQ-5D-5L index score and between the Malay and English versions of the EQ-VAS score. No significant difference was found in responses to EQ-5D-5L items between any languages, except that patients who chose to complete the Chinese version were more likely to report "no problems" in mobility compared to those who completed the Malay version of the questionnaire. This study provided evidence for the measurement equivalence of the different language versions of EQ-5D-5L in Singapore.

  17. Low-level arsenic exposure via drinking water consumption and female fecundity - A preliminary investigation.

    Science.gov (United States)

    Susko, Michele L; Bloom, Michael S; Neamtiu, Iulia A; Appleton, Allison A; Surdu, Simona; Pop, Cristian; Fitzgerald, Edward F; Anastasiu, Doru; Gurzau, Eugen S

    2017-04-01

    High level arsenic exposure is associated with reproductive toxicity in experimental and observational studies; however, few data exist to assess risks at low levels. Even less data are available to evaluate the impact of low level arsenic exposure on human fecundity. Our aim in this pilot study was a preliminary evaluation of associations between low level drinking water arsenic contamination and female fecundity. This retrospective study was conducted among women previously recruited to a hospital-based case-control study of spontaneous pregnancy loss in Timiṣ County, Romania. Women (n=94) with planned pregnancies of 5-20 weeks gestation completed a comprehensive physician-administered study questionnaire and reported the number of menstrual cycles attempting to conceive as the time to pregnancy (TTP). Drinking water samples were collected from residential drinking water sources and we determined arsenic levels using hydride generation-atomic absorption spectrometry (HG-AAS). Multivariable Cox-proportional hazards regression with Efron approximation was employed to evaluate TTP as a function of drinking water arsenic concentrations among planned pregnancies, adjusted for covariates. There was no main effect for drinking water arsenic exposure, yet the conditional probability for pregnancy was modestly lower among arsenic exposed women with longer TTPs, relative to women with shorter TTPs, and relative to unexposed women. For example, 1µg/L average drinking water arsenic conferred 5%, 8%, and 10% lower likelihoods for pregnancy in the 6th, 9th, and 12th cycles, respectively (P=0.01). While preliminary, our results suggest that low level arsenic contamination in residential drinking water sources may further impair fecundity among women with longer waiting times; however, this hypothesis requires confirmation by a future, more definitive study. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can

  19. Directions in low-level radioactive waste management. The siting process: establishing a low-level waste-disposal facility

    International Nuclear Information System (INIS)

    1982-11-01

    The siting of a low-level radioactive waste disposal facility encompasses many interrelated activities and, therefore, is inherently complex. The purpose of this publication is to assist state policymakers in understanding the nature of the siting process. Initial discussion focuses on the primary activities that require coordination during a siting effort. Available options for determining site development, licensing, regulating, and operating responsibilities are then considered. Additionally, the document calls attention to technical services available from federal agencies to assist states in the siting process; responsibilities of such agencies are also explained. The appendices include a conceptual plan for scheduling siting activities and an explanation of the process for acquiring agreement state status. An agreement state takes responsibility for licensing and regulating a low-level waste facility within its borders

  20. Low level radioactive waste management and discharge policies in Turkey

    International Nuclear Information System (INIS)

    Oezdemir, T.; Oezdemir, C.; Uslu, I.

    2005-01-01

    The legal infrastructure in Turkey for the management of low-level radioactive waste covers the liquid, solid and gaseous wastes. Management of these radioactive wastes is briefly described in this paper. Moreover, delay and decay tank systems that are used to collect and store the low level radioactive wastes as a part of low-level radioactive effluent discharge policy are introduced. (author)

  1. Comparison of Two Intensities of Aerobic Training (low intensity and High Intensity on Expression of Perlipin 2 Skeletal Muscle, Serum Glucose and Insulin levels in Streptozotocin-Diabetic Rats

    Directory of Open Access Journals (Sweden)

    M Ghafari

    2017-06-01

    Full Text Available Abstract   Background & aim: Lipid metabolism disorder plays an important role in insulin resistance in skeletal muscle and lipid drop proteins such as perlipine 2 (PLIN2 are effective in regulating intracellular fat metabolism. One of the suggested pathways for the effects of endurance activity in metabolic diseases is the effect of physical activity on intramuscular. Therefore, the purpose of this study was compare the intensity of aerobic exercise intensity (low intensity and high intensity on expression of PLIN2 skeletal muscle, serum glucose and insulin levels in streptozotocin-diabetic rats.   Methods: In this experimental study, 24 male Wistar rats were randomly divided into three groups of 8, including two intervention groups (low intensity endurance training group and high intensity continuous exercise group and one control group. After induction of diabetic rats by injection streptozotocin (55 mg / kg body weight, Intraperitoneally, endurance training was applied for eight weeks, three sessions per week in diabetic rats. Exercise intensity in the low-intensity group was equal to 5-8 m / min (equivalent to 50-60% Vo2max, the intensity of training in a high intensity training group was equivalent to a speed of 22-25 m / min (equivalent to 80% Vo2max and the control group did not receive intervene in this time. Relative protein expression of PLIN2 was performed using western blot technique. Data were analyzed by one-way ANOVA and Tukey's post hoc test.   Results: The results of the intergroup comparison revealed a significant difference among three groups in the PLIN2 variables (p = 0.037. The results of post hoc test showed a significant increase in PLIN2 in high intensity training diabetic group compared to the control group (p = 0.033 However, there was no significant difference in PLIN2 level in the low exercise group compared to the control group (p = 0.18. Also, there was no significant difference between the low intensity and

  2. Equivalence relations of AF-algebra extensions

    Indian Academy of Sciences (India)

    In this paper, we consider equivalence relations of *-algebra extensions and describe the relationship between the isomorphism equivalence and the unitary equivalence. We also show that a certain group homomorphism is the obstruction for these equivalence relations to be the same.

  3. Low level waste management at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Rodgers, A.D.; Truitt, D.J.; Logan, J.A.; Brown, R.M.

    1986-02-01

    EG and G Idaho, Inc. is the lead contractor for the Department of Energy (DOE) National Low Level Waste Management Program, established in 1979. In this role, the company uses its waste management expertise to provide management and technical direction to support the disposal of low-level waste (LLW) in a manner that protects the environment and the public health and safety while improving efficiency and cost-effectiveness. Program activities are divided into two areas: defense-related and commercial nuclear reactor programs. The defense program was established to develop technology improvements, provide technology transfer, and to ensure a more efficient and uniform system for low level waste disposal. To achieve the program's goals, it is necessary to improve, document, and, where necessary, develop new methods for waste generation reduction, waste treatment, shallow-land burial, greater confinement disposal, and measures to correct existing site deficiencies. The commercial low level waste management program provides support to assist the states in developing an effective national low level waste management system and provides technical assistance for siting of regional commercial LLW disposal sites. The program provides technical and informational support to state officials, low level waste generators, managers, and facility operators to resolve low level waste problems and to improve the systems' overall effectiveness. Procedures are developed and documented and made available to commercial users through this program. Additional work is being conducted to demonstrate the stabilization and closure of low level radioactive waste disposal sites and develop the criteria and procedures for acceptance of such sites by the Department of Energy after closure has been completed. 7 refs., 6 figs., 1 tab

  4. Low-level radiation waste management system

    International Nuclear Information System (INIS)

    Kubofcik, K.W.

    1990-01-01

    This patent describes a low-level radiation waste container set for use in conjunction with an open-topped receptacle. It comprises: a receptacle liner having a closed end and an open end, the receptacle liner sized for deployment as an inserted liner in an open-topped receptacle for collecting low-level radiation waste material within the receptacle liner within the open-topped receptacle; a cover sized and shaped to fit over the open top of the open-topped receptacle and the receptacle liner therein with the cover is in a closed position. The cover having a depending skirt which, when the cover is in the closed position, extends downwardly to overlap the open-topped receptacle adjacent the open top thereof and a portion of the receptacle liner received therein; and the receptacle liner and cover being fabricated of flexible radiation shielding material

  5. Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging

    International Nuclear Information System (INIS)

    Yao Dezhong; He Bin

    2003-01-01

    In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping

  6. Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yao Dezhong [School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu City, 610054, Sichuan Province (China); He Bin [The University of Illinois at Chicago, IL (United States)

    2003-11-07

    In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping.

  7. State and Federal activities on low-level waste

    International Nuclear Information System (INIS)

    1983-01-01

    With the passage of the Low-Level Waste Policy Act in December 1980, the states have assumed the management responsibility and the federal government has become a facilitator. State and Federal roles in regulation have not altered. This paper reviews the developments over the last two years to point out the progress made and critical steps that lie ahead. Both technological and political aspects are covered, and a conclusion is presented with a look to the future. Since compact development in the tool chosen by the politicans for low-level waste management, the author reviews the present status starting with the northwest compact which has been introduced into the House and Senate and is subject to hearings. The past two years have seen real progress in technology in the broadest sense. An information development and dissemination system was established in 1978 wih the state-by-state assessment of low-level waste disposal. Annual examinations have been made through 1981 which enables one to understand the generation of low-level wastes. Policy level planning by states can be supported by the base level of information available. Incineration of dry active waste and other non-fuel cycle waste is ready to be fully accepted. Much work has been done on volume reduction of liquids. The increased understanding of the ways to make a disposal site work represents a major technolological improvement. Within the DOE system, there is beginning to be a real understanding of the critical parameters in disposal site performance in the East

  8. Evaluation of tissue-equivalent materials to be used as human brain tissue substitute in dosimetry for diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C.C., E-mail: cassio.c.ferreira@gmail.co [Departamento de Fisica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil); Ximenes Filho, R.E.M., E-mail: raimundoximenes@hotmail.co [Departamento de Fisica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil); Vieira, J.W., E-mail: jwvieira@br.inter.ne [Centro Federal de Educacao Tecnologica de Pernambuco (CEFET-PE), Av. Professor Luiz Freire, 500 Curado, CEP 50740-540, Recife (Brazil); Escola Politecnica de Pernambuco, Universidade de Pernambuco (EPP/UPE), Rua Benfica, 455, Madalena, CEP 50720-001, Recife (Brazil); Tomal, A., E-mail: alessandratomal@pg.ffclrp.usp.b [Departamento de Fisica e Matematica, FFCLRP, Universidade de Sao Paulo, Ribeirao Preto-SP 14040-90 (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.b [Departamento de Fisica e Matematica, FFCLRP, Universidade de Sao Paulo, Ribeirao Preto-SP 14040-90 (Brazil); Garcia, C.A.B., E-mail: cgarcia@ufs.b [Departamento de Quimica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil); Maia, A.F., E-mail: afmaia@ufs.b [Departamento de Fisica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil)

    2010-08-15

    Tissue-equivalent materials to be used as substitutes for human brain tissue in dosimetry for diagnostic radiology have been investigated in terms of calculated total mass attenuation coefficient ({mu}/{rho}), calculated mass energy-absorption coefficient ({mu}{sub en}/{rho}) and absorbed dose. Measured linear attenuation coefficients ({mu}) have been used for benchmarking the calculated total mass attenuation coefficient ({mu}/{rho}). The materials examined were bolus, nylon (registered) , orange articulation wax, red articulation wax, PMMA (polymethylmethacrylate), bees wax, paraffin I, paraffin II, pitch and water. The results show that water is the best substitute for brain among the materials investigated. The average percentage differences between the calculated {mu}/{rho} and {mu}{sub en}/{rho} coefficients for water and those for brain were 1.0% and 2.5%, respectively. Absorbed doses determined by Monte Carlo methods confirm water as being the best brain substitute to be used in dosimetry for diagnostic radiology, showing maximum difference of 0.01%. Additionally this study showed that PMMA, a material often used for the manufacturing of head phantoms for computed tomography, cannot be considered to be a suitable substitute for human brain tissue in dosimetry.

  9. Low-level radiation: The cancer controversy

    International Nuclear Information System (INIS)

    Stewart, A.M.

    1990-01-01

    According to early studies it would be safe to assume there are no late effects of radiation apart from cancer, no lasting selective effects of the early deaths of A-bomb victims, and no cancer risk at low dose levels (below 20 rad). The nuclear establishment had good reason to believe that a potentially dangerous situation had been completely defused, and optimists were still free to regard daily exposure to background radiation as a benign influence. For several years the only indication to the contrary was the Oxford survey's finding on prenatal X-rays. But today we face the possibility that there are other late effects of radiation besides cancer; and the possibility that the selection effects of the two nuclear explosions are still reflected in death rates among survivors and are the reason why no cancer effects have been found at low dose levels. If these possibilities are confirmed, we may one day realize how fortunate it was that the Oxford survey findings put a brake on the enthusiasms of nuclear power advocates. Otherwise, we might never have pressed for direct studies of the effects of low doses of radiation. 7 refs

  10. Method of processing low-level radioactive liquid wastes

    International Nuclear Information System (INIS)

    Matsunaga, Ichiro; Sugai, Hiroshi.

    1984-01-01

    Purpose: To effectively reduce the radioactivity density of low-level radioactive liquid wastes discharged from enriched uranium conversion processing steps or the likes. Method: Hydrazin is added to low-level radioactive liquid wastes, which are in contact with iron hydroxide-cation exchange resins prepared by processing strongly acidic-cation exchange resins with ferric chloride and aqueous ammonia to form hydrorizates of ferric ions in the resin. Hydrazine added herein may be any of hydrazine hydrate, hydrazine hydrochloride and hydranine sulfate. The preferred addition amount is more than 100 mg per one liter of the liquid wastes. If it is less than 100 mg, the reduction rate for the radioactivety density (procession liquid density/original liquid density) is decreased. This method enables to effectively reduce the radioactivity density of the low-level radioactive liquid wastes containing a trace amount of radioactive nucleides. (Yoshihara, H.)

  11. Testing statistical hypotheses of equivalence

    CERN Document Server

    Wellek, Stefan

    2010-01-01

    Equivalence testing has grown significantly in importance over the last two decades, especially as its relevance to a variety of applications has become understood. Yet published work on the general methodology remains scattered in specialists' journals, and for the most part, it focuses on the relatively narrow topic of bioequivalence assessment.With a far broader perspective, Testing Statistical Hypotheses of Equivalence provides the first comprehensive treatment of statistical equivalence testing. The author addresses a spectrum of specific, two-sided equivalence testing problems, from the

  12. Meta-regression analysis to evaluate relationships between maternal blood levels of placentation biomarkers and low delivery weight.

    Science.gov (United States)

    Goto, Eita

    2018-05-03

    Caution is required for women at increased risk of low neonatal delivery weight. To evaluate relationships between maternal placentation biomarkers and the odds of low delivery weight. Databases including PubMed/MEDLINE were searched up to May 2017 using keywords involving biomarker names and "low birthweight." English language studies providing true- and false-positive, and true- and false-negative results of low delivery weight classified by maternal blood levels of placentation biomarkers (in units of multiple of the mean [MoM]) were included. Coefficients representing changes in log odds ratio for low delivery weight per 1 MoM increase in maternal blood placentation biomarkers, and those adjusted for race, sampling period, and/or study quality were calculated. Adjusted coefficients representing changes in log odds ratio for low delivery weight per 1 MoM increase in maternal blood levels of α-fetoprotein (AFP) and β-human chorionic gonadotropin (β-hCG) were significantly greater than 0 (both Plow delivery weight. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Low-level waste forum meeting reports

    International Nuclear Information System (INIS)

    1991-01-01

    This report contains highlights from the 1991 fall meeting of the Low Level Radioactive Waste Forum. Topics included legal updates; US NRC updates; US EPA updates; mixed waste issues; financial assistance for waste disposal facilities; and a legislative and policy report

  14. Low-level radioactive waste management options

    International Nuclear Information System (INIS)

    Schmalz, R.F.

    1989-01-01

    This paper discusses the non-technical problems associated with the social and political obstacles to the secure disposal of low level radioactive waste. The author reviews thirty years' experience managing non-military wastes. The merits of available options are considered

  15. A general method to quantify quasi-equivalence in icosahedral viruses.

    Science.gov (United States)

    Damodaran, K V; Reddy, Vijay S; Johnson, John E; Brooks, Charles L

    2002-12-06

    A quantitative, atom-based, method is described for comparing protein subunit interfaces in icosahedral virus capsids with quasi-equivalent surface lattices. An integrated, normalized value (between 0 and 1) based on equivalent residue contacts (Q-score) is computed for every pair of subunit interactions and scores that are significantly above zero readily identify interfaces that are quasi-equivalent to each other. The method was applied to all quasi-equivalent capsid structures (T=3, 4, 7 and 13) in the Protein Data Bank and the Q-scores were interpreted in terms of their structural underpinnings. The analysis allowed classification of T=3 structures into three groups with architectures that resemble different polyhedra with icosahedral symmetry. The preference of subunits to form dimers in the T=4 human Hepatitis B virus capsid (HBV) was clearly reflected in high Q-scores of quasi-equivalent dimers. Interesting differences between the classical T=7 capsid and polyoma-like capsids were also identified. Application of the method to the outer-shell of the T=13 Blue tongue virus core (BTVC) highlighted the modest distortion between the interfaces of the general trimers and the strict trimers of VP7 subunits. Furthermore, the method identified the quasi 2-fold symmetry in the inner capsids of the BTV and reovirus cores. The results show that the Q-scores of various quasi-symmetries represent a "fingerprint" for a particular virus capsid architecture allowing particle classification into groups based on their underlying structural and geometric features.

  16. What Do Contrast Threshold Equivalent Noise Studies Actually Measure? Noise vs. Nonlinearity in Different Masking Paradigms.

    Directory of Open Access Journals (Sweden)

    Alex S Baldwin

    Full Text Available The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system's input has on its output one can estimate the variance of this internal noise. By applying this simple "linear amplifier" model to the human visual system, one can entirely explain an observer's detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system's internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity. Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF. We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies.

  17. Performance assessment strategy for low-level waste disposal sites

    International Nuclear Information System (INIS)

    Starmer, R.J.; Deering, L.G.; Weber, M.F.

    1988-01-01

    This paper describes US Nuclear Regulatory Commission (NRC) staff views on predicting the performance of low-level radioactive waste disposal facilities. Under the Atomic Energy Act, as amended, and the Low Level Radioactive Waste Policy Act, as amended, the NRC and Agreement States license land disposal of low-level radioactive waste (LLW) using the requirements in 10 CFR Part 61 or comparable state requirements. The purpose of this paper is to briefly describe regulatory requirements for performance assessment in low-level waste licensing, a strategy for performance assessments to support license applications, and NRC staff licensing evaluation of performance assessments. NRC's current activities in developing a performance assessment methodology will provide an overall systems modeling approach for assessing the performance of LLW disposal facilities. NRC staff will use the methodology to evaluate performance assessments conducted by applicants for LLW disposal facilities. The methodology will be made available to states and other interested parties

  18. Research on near-surface disposal of very low level radioactive waste

    International Nuclear Information System (INIS)

    Wang Shaowei; Yue Huiguo; Hou Jie; Chen Haiying; Zuo Rui; Wang Jinsheng

    2012-01-01

    Radioactive waste disposal is one of the most sensitive environmental problems to control and solve. As the arriving of decommissioning of early period nuclear facilities in China, large amounts of very low level radioactive waste will be produced inevitably. The domestic and abroad definitions about very low level radioactive waste and its disposal were introduced, and then siting principles of near-surface disposal of very low level radioactive waste were discussed. The near- surface disposal siting methods of very low level radioactive waste were analyzed from natural and geographical conditions assessment, geological conditions analysis, hydrogeological conditions analysis, geological hazard assessment and radioactive background investigation; the near-surface disposal sites'natural barriers of very low level radioactive waste were analyzed from the crustal structure and physico-chemical characteristics, the dynamics characteristics of groundwater, the radionuclide adsorption characteristics of natural barriers and so on; the near-surface disposal sites' engineered barriers of very low level radioactive waste were analyzed from the repository design, the repository barrier materials selection and so on. Finally, the improving direction of very low level radioactive waste disposal was proposed. (authors)

  19. Low-Frequency Cortical Entrainment to Speech Reflects Phoneme-Level Processing.

    Science.gov (United States)

    Di Liberto, Giovanni M; O'Sullivan, James A; Lalor, Edmund C

    2015-10-05

    The human ability to understand speech is underpinned by a hierarchical auditory system whose successive stages process increasingly complex attributes of the acoustic input. It has been suggested that to produce categorical speech perception, this system must elicit consistent neural responses to speech tokens (e.g., phonemes) despite variations in their acoustics. Here, using electroencephalography (EEG), we provide evidence for this categorical phoneme-level speech processing by showing that the relationship between continuous speech and neural activity is best described when that speech is represented using both low-level spectrotemporal information and categorical labeling of phonetic features. Furthermore, the mapping between phonemes and EEG becomes more discriminative for phonetic features at longer latencies, in line with what one might expect from a hierarchical system. Importantly, these effects are not seen for time-reversed speech. These findings may form the basis for future research on natural language processing in specific cohorts of interest and for broader insights into how brains transform acoustic input into meaning. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Fractional sunburn threshold UVR doses generate equivalent vitamin D and DNA damage in skin types I-VI, but with epidermal DNA damage gradient correlated to skin darkness.

    Science.gov (United States)

    Shih, Barbara B; Farrar, Mark D; Cooke, Marcus S; Osman, Joanne; Langton, Abigail K; Kift, Richard; Webb, Ann R; Berry, Jacqueline L; Watson, Rachel E B; Vail, Andy; de Gruijl, Frank R; Rhodes, Lesley E

    2018-05-03

    Public health guidance recommends limiting sun-exposure to sub-sunburn levels, but it's unknown whether these can gain vitamin D (for musculoskeletal health) whilst avoiding epidermal DNA damage (initiates skin cancer). Well-characterised healthy humans of all skin types (I-VI; lightest to darkest skin) were exposed to a low dose-series of solar simulated UVR of 20-80% their individual sunburn threshold dose (minimal erythemal dose, MED). Significant UVR dose-responses were seen for serum 25(OH)D and whole epidermal CPD, with as little as 0.2 MED concurrently producing 25(OH)D and CPD. Notably, fractional MEDs generated equivalent levels of whole epidermal CPD and 25(OH)D across all skin types. Crucially, we demonstrated an epidermal gradient of CPD formation strongly correlated with skin darkness (r=0.74; Pskin types, ranging from darkest skin, where high CPD levels occurred superficially with none in the germinative basal layer, through to lightest skin where CPD were induced evenly across the epidermal depth. Darker skin people can be encouraged to utilise sub-sunburn UVR-exposure to enhance their vitamin D. In lighter skin people, basal cell damage occurs concurrent with vitamin D synthesis at exquisitely low UVR levels, providing an explanation for their high skin cancer incidence; greater caution is required. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.