WorldWideScience

Sample records for low-field insertion devices

  1. A study of the suitability of ferrite for use in low-field insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K.; Hassenzahl, W.V.

    1995-02-01

    Most insertion devices built to date use rare-earth permanent-magnet materials, which have a high remanent field and are more expensive than many other permanent-magnet materials. Low-field insertion devices could use less-expensive, lower performance magnetic materials if they had suitable magnetic characteristics. These materials must be resistant to demagnetization during construction and operation of the insertion device, have uniform magnetization, possess low minor-axis magnetic moments, and have small minor field components on the surfaces. This paper describes an investigation to determine if ferrite possesses magnetic qualities suitable for insertion device applications. The type of ferrite investigated, MMPA Ceramic 8 from Stackpole Inc., was found to be acceptable for insertion device applications.

  2. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  3. Low-field magnetotransport in graphene cavity devices

    Science.gov (United States)

    Zhang, G. Q.; Kang, N.; Li, J. Y.; Lin, Li; Peng, Hailin; Liu, Zhongfan; Xu, H. Q.

    2018-05-01

    Confinement and edge structures are known to play significant roles in the electronic and transport properties of two-dimensional materials. Here, we report on low-temperature magnetotransport measurements of lithographically patterned graphene cavity nanodevices. It is found that the evolution of the low-field magnetoconductance characteristics with varying carrier density exhibits different behaviors in graphene cavity and bulk graphene devices. In the graphene cavity devices, we observed that intravalley scattering becomes dominant as the Fermi level gets close to the Dirac point. We associate this enhanced intravalley scattering to the effect of charge inhomogeneities and edge disorder in the confined graphene nanostructures. We also observed that the dephasing rate of carriers in the cavity devices follows a parabolic temperature dependence, indicating that the direct Coulomb interaction scattering mechanism governs the dephasing at low temperatures. Our results demonstrate the importance of confinement in carrier transport in graphene nanostructure devices.

  4. Insertion device calculations with mathematica

    Energy Technology Data Exchange (ETDEWEB)

    Carr, R. [Stanford Synchrotron Radiation Lab., CA (United States); Lidia, S. [Univ. of California, Davis, CA (United States)

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  5. Field errors in hybrid insertion devices

    International Nuclear Information System (INIS)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed

  6. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  7. Recent advances in insertion devices

    International Nuclear Information System (INIS)

    Gluskin, E.; Moog, E.R.

    1995-01-01

    Demand for more and better insertion devices (IDs) at new third-generation synchrotron radiation facilities has led to significant advances in ID technology at different laboratories around the world. In this overview of this progress, focus is on those results that apply to IDs in general rather than one specific ID or laboratory. The advances fall into two general categories: those that reduce the net effect that the ID has on the particle beam, and those that enhance the quality of the emitted light spectrum. The need for these advances, factors that are most important inaachieving them, and the current state of the art are discussed

  8. Insertion device and method for accurate and repeatable target insertion

    Science.gov (United States)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  9. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  10. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  11. Symplectic models for general insertion devices

    International Nuclear Information System (INIS)

    Wu, Y.; Forest, E.; Robin, D. S.; Nishimura, H.; Wolski, A.; Litvinenko, V. N.

    2001-01-01

    A variety of insertion devices (IDs), wigglers and undulators, linearly or elliptically polarized,are widely used as high brightness radiation sources at the modern light source rings. Long and high-field wigglers have also been proposed as the main source of radiation damping at next generation damping rings. As a result, it becomes increasingly important to understand the impact of IDs on the charged particle dynamics in the storage ring. In this paper, we report our recent development of a general explicit symplectic model for IDs with the paraxial ray approximation. High-order explicit symplectic integrators are developed to study real-world insertion devices with a number of wiggler harmonics and arbitrary polarizations

  12. Insertion Device Upgrade Plans at the NSLS

    CERN Document Server

    Tanabe, Toshiya; Harder, David; Lehecka, Michael; Rakowsky, George; Skaritka, John

    2005-01-01

    This paper describes plans to upgrade insertion devices at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W80) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-18) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, in-vacuum undulator (MGU-13.5), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both MGU’s will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement methods in low temperature will be discussed.

  13. Hardening device, by inserts, of electronic component against radiation

    International Nuclear Information System (INIS)

    Val, C.

    1987-01-01

    The hardening device includes at least two materials, one with high atomic number with respect to the other. One of these materials is set as inserts in a layer of the other material. The hardening device is then made by stacking of such layers, the insert density varying from one layer to the other, making thus vary the atomic number resulting from the hardening device along its thickness, following a predefined law [fr

  14. Calculation of magnetic error fields in hybrid insertion devices

    International Nuclear Information System (INIS)

    Savoy, R.; Halbach, K.; Hassenzahl, W.; Hoyer, E.; Humphries, D.; Kincaid, B.

    1989-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory requires insertion devices with fields sufficiently accurate to take advantage of the small emittance of the ALS electron beam. To maintain the spectral performance of the synchrotron radiation and to limit steering effects on the electron beam these errors must be smaller than 0.25%. This paper develops a procedure for calculating the steering error due to misalignment of the easy axis of the permanent magnet material. The procedure is based on a three dimensional theory of the design of hybrid insertion devices developed by one of us. The acceptable tolerance for easy axis misalignment is found for a 5 cm period undulator proposed for the ALS. 11 refs., 5 figs

  15. The first insertion devices at SSRL - some personal recollections

    Energy Technology Data Exchange (ETDEWEB)

    Winick, H. [Stanford Linear Accelerator Center, CA (United States)

    1995-02-01

    The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.

  16. Micropole undulators: Novel insertion devices for synchrotron sources

    International Nuclear Information System (INIS)

    Toor, A.; Csonka, P.; Tatchyn, R.

    1989-01-01

    Micropole undulators (wigglers) are undulators (wigglers) with submillimeter periods and are referred to, generically, as micropole insertion devices. Compared to ordinary insertion devices, whose period λ u is typically ≥l cm, micropole devices have periods smaller by a factor f≤10. Therefore, the first-harmonic radiation emitted by a micropole undulator will have its photon energy E γ increased by f and its spectral purity Δλ/λ by f, provided the total length of the undulator l u stays unchanged, and magnetic field errors, as well as the electron-beam emittance, are sufficiently small. Furthermore, to generate photons of the same E γ as from the conventional device, the electron-beam energy E e can be reduced by f 1/2 , resulting in significantly lower construction and operating costs. Radiative energy losses can be correspondingly diminished for the associated storage rings. In this paper we report on results recently obtained by us in the practical implementation and design of micropole undulators at the Stanford Synchrotron Radiation Laboratory (SSRL) and the Lawrence Livermore National Laboratory (LLNL). Based on our work, micropole undulators with f≤10 4 appear feasible at the present time

  17. A new gap separation mechanism for APS insertion devices

    International Nuclear Information System (INIS)

    Trakhtenberg, E. M.; Tcheskidov, V.; Den Hartog, P. K.; Deriy, B.; Erdmann, M.; Makarov, O.; Moog, E. R.

    1999-01-01

    A new gap separation mechanism for use with the standard Advanced Photon Source (APS) 3.3-cm-period undulator magnetic structures has been designed and built and the first system has been installed in the APS storage ring. The system allows a minimum magnetic gap of 10 mm for use with the APS 8-mm insertion device vacuum chambers. The mechanism is a bolted steel frame structure with a simple 4-motor mechanical drive train. The control system uses servomotors with incremental rotary encoders and virtual absolute linear encoders

  18. Parametric mechanical design of new insertion devices at the APS.

    Energy Technology Data Exchange (ETDEWEB)

    Grimmer, J.; Kmak, R.

    2005-01-01

    Three permanent-magnet, planar, hybrid insertion device (ID) designs have recently been completed at the APS. The periods of these undulators are 2.7 cm, 3.0 cm and 3.5 cm with nominal lengths of 2.4 m. Several design studies were performed for the initial 2.7-cm-period device. Then a parametric solid model for the initial device was developed and value engineered to minimize manufacturing, assembly and tuning costs. The model allowed the very rapid design of subsequent devices of similar periods and allowed commonality of several components of the IDs. This design family incorporates a low-cost method of pole retention and registration. Poles are secured by screws in two holes tapped into each pole. Pole location is registered by means of two small dowel pins in mating holes reamed into each pole and a 'divider' plate common to the poles and magnets. This divider plate is flexible along its length so shimming behind it can be used to accurately change the height of a pair of poles for tuning. Another feature of the design is modular construction to allow each device to be used full length or shortened to a nominal 2.1 m length for use in APS 'canted undulator' sectors.

  19. Fixed mask assembly research for APS insertion devices

    International Nuclear Information System (INIS)

    Kuzay, T.M.

    1992-01-01

    The Fixed Mask Assembly (FMA) is the first component to interact with the photon beam. Two sets of a pair of FMA channels, vertically and horizontally disposed, contain the beam rather than define it. They are subject to very large heat fluxes during containment. In current practice, the FMA channels are made of heavy, seamless copper, have rectangular cross-sections, and are cooled internally with water. Channels are set at grazing angles ranging from I to 6 degrees with respect to the beam, depending on the type of insertion device. APS insertion devices will impose higher heat fluxes on FMAS. Therefore, a need exists to improve the FMA engineering, keeping in mind the current design criteria and philosophy of FMAS. Preliminary analysis of current heat transfer practice indicates that the major resistance to heat transfer is on the coolant side. Therefore, FMA cooling would benefit from enhanced heat transfer on the coolant side. With this principle in mind, an experimental program has been undertaken to explore the feasibility of using high-performance copper tube configurations which are expected to yield heat transfer coefficients, open-quotes hclose quotes, in single phase flow systems 2 to 5(?) times higher than equivalent plain tubes. In this report, the experimental scope and a preliminary analysis of high-performance copper tube configurations are described

  20. Type testing of devices with inserted radioactive sources

    International Nuclear Information System (INIS)

    Rolle, A.; Droste, B.; Dombrowski, H.

    2006-01-01

    In Germany devices with inserted radioactive sources can get a type approval if they comply with specific requirements. Whoever operates a device whose type has been approved in accordance with the German Radiation Protection Ordinance does not need an individual authorization. Such type approvals for free use are granted by the Federal Office for Radiation Protection (B.f.S.) on the basis of type testing performed by the Physikalisch-Technische Bundesanstalt (P.T.B.), the national metrology institute, and the Bundesanstalt fur Materialforschung und -prufung (B.A.M.), the Federal Institute for Materials Research and Testing. Main aspects of the assessment are the activity of the radioactive sources, the dose equivalent rate near the devices, the tamper-proofness and leak-tightness of the sources and the safety of the construction of the devices. With the new Radiation Protection Ordinance in 2001, more stringent requirements for a type approval were established. Experiences with the new regulations and the relevant assessment criteria applied by P.T.B. and B.A.M. will be presented. (authors)

  1. Development trends for insertion devices of future synchrotron light sources

    Directory of Open Access Journals (Sweden)

    C. S. Hwang

    2011-04-01

    Full Text Available The in-vacuum undulator with a permanent magnet at room temperature is a mature technology and is widely used; with a short period length in a medium-energy facility, it can enhance photon brilliance in the hard x-ray region. A cryogenic permanent magnet has been investigated as an in-vacuum undulator; this undulator will become the best prospective device to satisfy the requirements of a photon source with great brilliance in the hard x-ray region. For the further hard x-ray region, a superconducting wiggler can provide great flux with a continuous spectrum, whereas a superconducting undulator will provide great brilliance with a discrete spectrum. High-temperature superconducting wires are highly promising for use in the development of superconducting undulators; unique algorithms for their development with an extremely short period in a small-magnet gap have been devised. Some out-of-vacuum planar undulators with special functions must also be fabricated to enable diverse applications in various light-source facilities. This article describes current and future developments for insertion devices in storage-ring and free-electron-laser facilities and discusses their feasibility for use therein.

  2. Parametric Mechanical Design of New Insertion Devices at the APS

    CERN Document Server

    Grimmer, John H

    2005-01-01

    Three permanent-magnet, planar, hybrid ID designs have recently been completed at the APS. The periods of the devices are 2.7 cm, 3.0 cm and 3.5 cm with nominal lengths of 2.4 m. Several design studies were performed for the initial 2.7 cm period device to investigate the utility of various design features. Then a parametric solid model for the initial device was developed and value engineered to minimize manufacturing, assembly and tuning costs. The model allowed the very rapid design of subsequent devices of similar periods and allowed commonality of several components of the IDs. This design family incorporates a low-cost method of pole retention and registration. Poles are secured by screws in two holes tapped into each pole. Pole location is registered by means of two small dowel pins for each pole in mating holes reamed into each pole and a base plate common to the poles and magnets. This base plate is flexible in bending along its length so shimming behind it can be used to accurately change the height...

  3. A Novel Device for Accurate Chest Tube Insertion

    DEFF Research Database (Denmark)

    Katballe, Niels; Moeller, Lars B; Olesen, Winnie H

    2016-01-01

    BACKGROUND: Optimal positioning of a large-bore chest tube is in the part of the pleural cavity that needs drainage. It is recommended that the chest tube be positioned apically in pneumothorax and basally for fluids. However, targeted chest tube positioning to a specific part of the pleural cavity...... can be a challenge. METHODS: A new medical device, the KatGuide, was developed for accurate guiding of a chest tube (28F) to an intended part of the pleural cavity. The primary end point of this randomized, controlled trial was optimal position of the chest tube. The optimal position in pneumothorax...

  4. Diamond MEMS: wafer scale processing, devices, and technology insertion

    Science.gov (United States)

    Carlisle, J. A.

    2009-05-01

    Diamond has long held the promise of revolutionary new devices: impervious chemical barriers, smooth and reliable microscopic machines, and tough mechanical tools. Yet it's been an outsider. Laboratories have been effectively growing diamond crystals for at least 25 years, but the jump to market viability has always been blocked by the expense of diamond production and inability to integrate with other materials. Advances in chemical vapor deposition (CVD) processes have given rise to a hierarchy of carbon films ranging from diamond-like carbon (DLC) to vapor-deposited diamond coatings, however. All have pros and cons based on structure and cost, but they all share some of diamond's heralded attributes. The best performer, in theory, is the purest form of diamond film possible, one absent of graphitic phases. Such a material would capture the extreme hardness, high Young's modulus and chemical inertness of natural diamond. Advanced Diamond Technologies Inc., Romeoville, Ill., is the first company to develop a distinct chemical process to create a marketable phase-pure diamond film. The material, called UNCD® (for ultrananocrystalline diamond), features grain sizes from 3 to 300 nm in size, and layers just 1 to 2 microns thick. With significant advantages over other thin films, UNCD is designed to be inexpensive enough for use in atomic force microscopy (AFM) probes, microelectromechanical machines (MEMS), cell phone circuitry, radio frequency devices, and even biosensors.

  5. The insertion device magnetic measurement facility: Prototype and operational procedures

    International Nuclear Information System (INIS)

    Burkel, L.; Dejus, R.; Maines, J.; O'Brien, J.; Vasserman, I.; Pfleuger, J.

    1993-03-01

    This report is a description of the current status of the magnetic measurement facility and is a basic instructional manual for the operation of the facility and its components. Please refer to the appendices for more detailed information about specific components and procedures. The purpose of the magnetic measurement facility is to take accurate measurements of the magnetic field in the gay of the IDs in order to determine the effect of the ID on the stored particle beam and the emitted radiation. The facility will also play an important role when evaluating new ideas, novel devices, and inhouse prototypes as part of the ongoing research and development program at the APS. The measurements will be performed with both moving search coils and moving Hall probes. The IDs will be evaluated by computer modeling of the emitted radiation for any given (measured) magnetic field map. The quality of the magnetic field will be described in terms of integrated multipoles for the effect on Storage Ring performance and in terms of the derived trajectories for the emitted radiation. Before being installed on the Storage Ring, every device will be measured and characterized to assure that it is compatible with Storage Ring requirements and radiation specifications. The accuracy that the APS needs to achieve for magnetic measurements will be based on these specifications

  6. Insertion devices and beamlines for the proposed Australian synchrotron light source

    International Nuclear Information System (INIS)

    Garrett, R.F.; Boldeman, J.W.

    1999-01-01

    Full text: The proposed Australian synchrotron light source, Boomerang, is a third generation 3 GeV storage ring which is designed to provide for the great majority of Australian requirements for synchrotron radiation well into the next century. The storage ring could accommodate up to 60 experimental stations, including beamlines from 9 insertion devices, which far exceeds the projected Australian requirements over the life of the facility. Undulator radiation will be available up to 20 keV. The first phase construction of Boomerang includes funding for 9 beamlines, comprising 5 bending magnet and 4 insertion device beamlines. The beamline complement has been chosen to cater for approximately 95% of the current and projected Australian demand for synchrotron radiation over the first 5 years operation of the facility. Details will be shown of the performance of the proposed insertion devices, and the initial beamline complement will be presented

  7. A multiple objective magnet sorting algorithm for the Advanced Light Source insertion devices

    International Nuclear Information System (INIS)

    Humphries, D.; Goetz, F.; Kownacki, P.; Marks, S.; Schlueter, R.

    1995-01-01

    Insertion devices for the Advanced Light Source (ALS) incorporate large numbers of permanent magnets which have a variety of magnetization orientation errors. These orientation errors can produce field errors which affect both the spectral brightness of the insertion devices and the storage ring electron beam dynamics. A perturbation study was carried out to quantify the effects of orientation errors acting in a hybrid magnetic structure. The results of this study were used to develop a multiple stage sorting algorithm which minimizes undesirable integrated field errors and essentially eliminates pole excitation errors. When applied to a measured magnet population for an existing insertion device, an order of magnitude reduction in integrated field errors was achieved while maintaining near zero pole excitation errors

  8. A multiple objective magnet sorting algorithm for the ALS insertion devices

    International Nuclear Information System (INIS)

    Humphries, D.; Goetz, F.; Kownacki, P.; Marks, S.; Schlueter, R.

    1994-07-01

    Insertion devices for the Advanced Light Source (ALS) incorporate large numbers of permanent magnets which have a variety of magnetization orientation errors. These orientation errors can produce field errors which affect both the spectral brightness of the insertion devices and the storage ring electron beam dynamics. A perturbation study was carried out to quantify the effects of orientation errors acting in a hybrid magnetic structure. The results of this study were used to develop a multiple stage sorting algorithm which minimizes undesirable integrated field errors and essentially eliminates pole excitation errors. When applied to a measured magnet population for an existing insertion device, an order of magnitude reduction in integrated field errors was achieved while maintaining near zero pole excitation errors

  9. Filter and window assemblies for high power insertion device synchrotron radiation sources

    International Nuclear Information System (INIS)

    Khounsary, A.M.; Viccaro, P.J.; Kuzay, T.M.

    1992-01-01

    The powerful beams of x-ray radiation generated by insertion devices at high power synchrotron facilities deposit substantial amounts of localized heat in the front end and optical components that they intercept. X-ray beams from undulator sources, in particular, are confined to very narrow solid angles and therefore impose very high absorbed heat fluxes. This paper is devoted to a detailed study of the design of windows for the Advanced Photon Source undulators and wigglers, emphasizing alternative design concepts, material considerations, and cooling techniques necessary for handling the high heat load of the insertion devices. Various designs are thermally and structurally analyzed by numerically simulating full-power operating conditions. This analysis also has relevance to the design and development of other beam line components which are subjected to the high heat loads of insertion devices

  10. Radiation dose measurements of the insertion devices using radiachromic film dosimeters

    International Nuclear Information System (INIS)

    Alderman, J.; Semones, E.; Job, P. K.

    2004-01-01

    The Advanced Photon Source (APS) uses Nd-Fe-B permanent magnets in the insertion devices to produce x-rays for scientific research [1,2]. Earlier investigations have exhibited varying degrees of demagnetization of these magnets [3] due to irradiation from electron beams [4,5,6], 60 Co γ-rays [5], and high-energy neutrons [7,8]. Radiation-induced demagnetization has been observed in the APS insertion devices [9] and was first measured in December of 2001. Partial demagnetization has also been observed in insertion devices at the European Synchrotron Radiation Facility (ESRF) [4,6], where Nd-Fe-B permanent magnets are also used. Growing concern for the lifetime of APS insertion devices, as well as the permanent magnets that will be used in next-generation, high-power light sources, like the FEL [10,11], resulted from the partial demagnetization observations made at both facilities. This concern in relation to radiation-induced demagnetization spurred a long-term project to measure and analyze the absorbed doses received by the APS insertion devices. The project required a reliable photon high-dose dosimetry technique capable of measuring absorbed doses greater than 10 6 rad, which was not readily available at the APS. Through a collaboration with the National Institute of Standards and Technology (NIST), one such technique using radiachromic films was considered, tested, and calibrated at the APS. This consequently led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the insertion devices for each of the APS runs

  11. Tune shift and betatron modulations due to insertion devices in SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.

    1989-12-01

    SPEAR will soon operate as a dedicated synchrotron radiation source with up to 5 beamlines fed from insertion devices. These magnets introduce additional focusing forces into the storage ring lattice which increase the vertical betatron tune and modulate the beam envelope in the vertical plane. The lattice simulation code 'GEMINI' is used to evaluate the tune shifts and estimate the degree of betatron modulation as each magnetic insertion device is brought up to full power. A program is recommended to correct the tunes with the FODO cell quadrupoles. 4 refs., 8 figs., 1 tab

  12. Study of low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices.

    Science.gov (United States)

    Jiang, Hua; Lu, Wenke; Zhang, Guoan

    2013-07-01

    In this paper, we propose a low insertion loss and miniaturization wavelet transform and inverse transform processor using surface acoustic wave (SAW) devices. The new SAW wavelet transform devices (WTDs) use the structure with two electrode-widths-controlled (EWC) single phase unidirectional transducers (SPUDT-SPUDT). This structure consists of the input withdrawal weighting interdigital transducer (IDT) and the output overlap weighting IDT. Three experimental devices for different scales 2(-1), 2(-2), and 2(-3) are designed and measured. The minimum insertion loss of the three devices reaches 5.49dB, 4.81dB, and 5.38dB respectively which are lower than the early results. Both the electrode width and the number of electrode pairs are reduced, thus making the three devices much smaller than the early devices. Therefore, the method described in this paper is suitable for implementing an arbitrary multi-scale low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Linear motion device and method for inserting and withdrawing control rods

    International Nuclear Information System (INIS)

    Smith, J. E.

    1984-01-01

    A linear motion device, more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core, is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism

  14. Reorientation simplified: A device for recording and reproducing the path of insertion for removable partial dentures

    Directory of Open Access Journals (Sweden)

    Vaibhav D Kamble

    2014-01-01

    Full Text Available Aim: The record of path of insertion on the dental cast is part of the dentist′s work authorization to the dental laboratory technician. The path of insertion record enables the dental technician to replace the cast on a surveyor in the same position that the dentist selected. Analysis of factors that influence the path of insertion should determine a path of insertion that will reduce the potential for dislodgement and promote stability of removable partial denture (RPD. Materials and Methods: The recording of the relation of a cast to a dental surveyor and the transfer of this relationship to the dental laboratory may be done by tripodization, by scoring the base of the cast, or by cementing a reference pin on the cast. Conclusion: Recording the established path of insertion can be difficult when the procedure uses a cemented pin and the casts are mounted in an articulator. This article describes a procedure for innovative dowel pin and sleeve device to record the path of insertion of RPDs, which serves the same purpose as the cemented pin but can be easily removed and replaced.

  15. Insertion device and beam line plans for the Advanced Photon Source: A report and recommendations by the Insertion Device and Beam Line Planning Committee

    International Nuclear Information System (INIS)

    1988-02-01

    In the 7-GeV Advanced Photon Source (APS) Conceptual Design Report (CDR), fifteen complete experimental beam lines were specified in order to establish a representative technical and cost base for the components involved. In order to optimize the composition of the insertion devices and the beam line, these funds are considered a ''Trust Fund.'' The present report evaluates the optimization for the distribution of these funds so that the short- and long-term research programs will be most productive, making the facility more attractive from the user's point of view. It is recommended that part of the ''Trust Fund'' be used for the construction of the insertion devices, the front-end components, and the first-optics, minimizing the cost to potential users of completing a beam line. In addition, the possibility of cost savings resulting from replication and standardization of high multiplicity components (such as IDs, front ends, and first-optics instrumentation) is addressed. 2 refs., 5 tabs

  16. Device for facilitating the insertion and withdrawal of fuel assemblies from a nuclear reactor

    International Nuclear Information System (INIS)

    Andrea, C.; Siegel, E.A.

    1976-01-01

    A device is provided which is installed in a reactor prior to carrying out refueling operations and which accurately locates and isolates a selected core location to permit rapid withdrawal and insertion of fuel subassemblies at that location. A shielded plug designed to cooperate with the refueling apparatus is inserted into an access port in the reactor head. A structural shroud extends down from the plug and carries at its lower end a radially floating, hexagonal spreader tube with mechanisms to rotate it for angular alignment purposes and a linear drive for inserting it into the core. The upper end of the spreader tube serves as a guide for leading the fuel handling apparatus into alignment with the chosen subassembly

  17. [Rare problem with the insertion of a Supreme™ laryngeal mask airway device. Case of the trimester].

    Science.gov (United States)

    2014-03-01

    A breast tumor was resected under general anesthesia. After induction, the airway was managed with a Supreme™ laryngeal mask airway device. The insertion of the laryngeal mask airway device, the insertion of the orogastric tube through the drain tube, as well as the mechanical ventilation, were very difficult from the beginning. On removing the laryngeal mask airway device to solve the problem, it was observed that the drain tube was broken, and the orogastric tube had passed into the anterior, laryngeal part of the device through the split. It was later found out that the laryngeal mask airway device, as well as the whole manufacturing batch, had suffered a design modification: the cuff was constructed with a softer material without reinforcement in the tip, and the drain tube had a heat-sealing defect that facilitated the break. The incident was reported to the local supplier and the manufacturer, and the defective batch of laryngeal mask airway devices was recalled. The incident was also reported to other hospitals via SENSAR, to warn other users of the potential dangers of the design modification in the Supreme™ laryngeal mask airway. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  18. Pain from copper intrauterine device insertion: randomized trial of prophylactic ibuprofen.

    Science.gov (United States)

    Hubacher, David; Reyes, Veronica; Lillo, Sonia; Zepeda, Ana; Chen, Pai-Lien; Croxatto, Horacio

    2006-11-01

    This study was undertaken to determine whether 400 mg of prophylactic ibuprofen can alleviate pain from insertion of an intrauterine device (IUD) and to measure level of pain with improved techniques. We conducted a randomized, double-blind, placebo-controlled trial of 2019 first-time IUD users: 1008 women received placebo and 1011 women received 400 mg of ibuprofen. Participants took the single tablet at least 45 minutes before IUD insertion. Immediately after insertion, participants recorded level of pain by using a 10-cm visual analog scale, with the value of 10 meaning "worst imaginable pain." Median level of pain was 1.0 for both ibuprofen and placebo participants; rank test statistics confirmed no difference. Some subgroups of women experienced higher pain (eg, nulliparous women), but ibuprofen still had no important impact on level of pain. Even among first-time users, pain from IUD insertion is generally low. Prophylactic ibuprofen as used in this protocol does not reduce IUD insertion pain.

  19. General overview and a review of storage rings, research facilities, and insertion devices

    International Nuclear Information System (INIS)

    Winick, H.

    1989-01-01

    Synchrotron radiation, the electromagnetic radiation given off by electrons in circular motion, is revolutionizing many branches of science and technology by offering beams of vacuum ultraviolet light and x rays of immense flux and brightness. In the past decade there has been an explosion of interest in these applications leading to increased exploitation of existing rings and activity to construct new research facilities based on advanced storage rings and insertion device sources. Applications include basic and applied research in biology, chemistry, medicine, and physics plus many areas of technology. In this article they present a general overview of the field of synchrotron radiation research, its history, the present status and future prospects of storage rings and research facilities, and the development of wiggler and undulator insertion devices as sources of synchrotron radiation. 66 references, 20 figures, 1 table

  20. Synchrotron radiation A general overview and a review of storage rings, research facilities, and insertion devices

    International Nuclear Information System (INIS)

    Winick, H.

    1989-01-01

    Synchrotron radiation, the electromagnetic radiation given off by electrons in circular motion, is revolutionizing many branches of science and technology by offering beams of vacuum ultraviolet light and x rays of immense flux and brightness. In the past decade there has been an explosion of interest in these applications leading activity to construct new research facilities based on advanced storage rings and insertion device sources. Applications include basic and applied research in biology, chemistry, medicine, and physics plus many areas of technology. In this article we present a general overview of the field of synchrotron radiation research, its history, the present status and future prospects of storage rings and research facilities, and the development of wiggler and undulator insertion devices as sources of synchrotron radiation

  1. Selected applications of planar permanent magnet multipoles in FEL insertion device design

    International Nuclear Information System (INIS)

    Tatchyn, R.

    1993-08-01

    In recent work, a new class of magnetic multipoles based on planar configurations of permanent magnet (PM) material has been developed. These structures, in particular the quadrupole and sextupole, feature fully open horizontal apertures, and are comparable in effectiveness to conventional iron multipole structures. In this paper results of recent measurements of planar PM quadrupoles and sextupoles are reported and selected applications to FEL insertion device design are considered

  2. New developments on the generation of arbitrary polarized radiation from insertion devices

    International Nuclear Information System (INIS)

    Elleaume, P.

    1991-01-01

    The complete description of the polarization of a beam of radiation is described in terms of the total energy and three polarization rates. The polarization characteristics from conventional undulators and wigglers is recalled. A presentation is made of some new insertion devices that were proposed and/or built to generate circular polarization and more generally to improve the control of polarization. They are the asymmetric and elliptical wigglers and the helical and crossed undulators

  3. Linear motion device and method for inserting and withdrawing control rods

    Science.gov (United States)

    Smith, J.E.

    Disclosed is a linear motion device and more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core. The CRDM and method disclosed is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.

  4. Radiological assessment of placement of the hysteroscopically inserted Essure permanent birth control device.

    Science.gov (United States)

    Lorente Ramos, R M; Azpeitia Armán, J; Aparicio Rodríguez-Miñón, P; Salazar Arquero, F J; Albillos Merino, J C

    2015-01-01

    Essure is a permanent birth control device that is inserted through the cervix by hysteroscopy. The device is placed in the fallopian tubes, where it causes occlusion by stimulating fibrosis. Patients can be followed up with plain-film X-rays, hysterosalpingography, and ultrasonography, although the devices can also be identified incidentally on CT and MRI. The follow-up of Essure is based on checking the criteria for appropriate positioning and correct functioning (tubal occlusion) and on diagnosing complications. The most common complications are perforation, migration (toward the uterine or peritoneal cavity), and occlusion failure. In hysterosalpingography, vascular intravasation is the most common cause of diagnostic error. Radiologists need to know how to recognize the device on different imaging techniques, how to check that it is correctly placed and functioning, and how to diagnose complications. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  5. Development of a tapping device: a new needle insertion method for prostate brachytherapy

    International Nuclear Information System (INIS)

    Lagerburg, V; Moerland, M A; Konings, M K; Vosse, R E van de; Lagendijk, J J W; Battermann, J J

    2006-01-01

    The purpose of this study is to develop and test a tapping device for needle insertion for prostate brachytherapy. This device will tap the needle into the prostate with a certain, well-defined, amount of momentum, instead of the currently used method of pushing the needle. Because of the high needle insertion velocity, we expect prostate motion and deformation to be less compared to current methods. We measured the momentum that is applied when manually tapping the needle into the prostate and found a mean momentum of 0.50 ± 0.07 N s. The tapping device is pneumatically driven and we found that the delivered momentum increased linearly with the applied air pressure. The efficacy of the tapping device was tested on a piece of beef, placed on a freely moving and rotating platform. A significant correlation was found between the applied pressure and the rotation and displacement of the beef. Displacements and rotations were minimal for the highest pressure (4 bar) and amounted to only 2 mm and 6 deg., respectively. Higher air pressures will further reduce displacements and rotations

  6. Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography

    Science.gov (United States)

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Arena, Monica; Iabichino, Giuseppe; Consolo, Pierluigi; Opocher, Enrico; Luigiano, Carmelo

    2016-01-01

    Stents are tubular devices made of plastic or metal. Endoscopic stenting is the most common treatment for obstruction of the common bile duct or of the main pancreatic duct, but also employed for the treatment of bilio-pancreatic leakages, for preventing post- endoscopic retrograde cholangiopancreatography pancreatitis and to drain the gallbladder and pancreatic fluid collections. Recent progresses in techniques of stent insertion and metal stent design are represented by new, fully-covered lumen apposing metal stents. These stents are specifically designed for transmural drainage, with a saddle-shape design and bilateral flanges, to provide lumen-to-lumen anchoring, reducing the risk of migration and leakage. This review is an update of the technique of stent insertion and metal stent deployment, of the most recent data available on stent types and characteristics and the new applications for biliopancreatic stents. PMID:26862364

  7. Cryogenic refrigeration requirements for superconducting insertion devices in a light source

    International Nuclear Information System (INIS)

    Green, Michael A.; Green, Michael A.; Green, Michael A.

    2003-01-01

    This report discusses cryogenic cooling superconducting insertion devices for modern light sources. The introductory part of the report discusses the difference between wiggler and undulators and how the bore temperature may affect the performance of the magnets. The steps one would take to reduce the gap between the cold magnet pole are discussed. One section of the report is devoted to showing how one would calculate the heat that enters the device. Source of heat include, heat entering through the vacuum chamber, heating due to stray electrons and synchrotron radiation, heating due to image current on the bore, heat flow by conduction and radiation, and heat transfer into the cryostat through the magnet leads. A section of the report is devoted to cooling options such as small cryo-cooler and larger conventional helium refrigerators. This section contains a discussion as to when it is appropriate to use small coolers that do not have J-T circuits. Candidate small cryo-coolers are discussed in this section of the report. Cooling circuits for cooling with a conventional refrigerator are also discussed. A section of the report is devoted to vibration isolation and how this may affect how the cooling is attached to the device. Vibration isolation using straps is compared to vibration isolation using helium heat pipes. The vibration isolation of a conventional refrigeration system is also discussed. Finally, the cool down of an insertion device is discussed. The device can either be cooled down using liquid cryogenic nitrogen and liquid helium or by using the cooler used to keep the devices cold over the long haul

  8. Surgical treatment of lumbar spinal stenosis with microdecompression and interspinous distraction device insertion. A case series

    Directory of Open Access Journals (Sweden)

    Ploumis Avraam

    2012-10-01

    Full Text Available Abstract Background Interspinous distraction devices (IPDD are indicated as stand-alone devices for the treatment of spinal stenosis. The purpose of this study is to evaluate the results of patients undergoing surgery for spinal stenosis with a combination of unilateral microdecompression and interspinous distraction device insertion. Methods This is a prospective clinical and radiological study of minimum 2 years follow-up. Twenty-two patients (average age 64.5 years with low-back pain and unilateral sciatica underwent decompressive surgery for lumbar spinal stenosis. Visual Analogue Scale, Oswestry Disability Index and walking capacity plus radiologic measurements of posterior disc height of the involved level and lumbar lordosis Cobb angle were documented both preoperatively and postoperatively. One-sided posterior subarticular and foraminal decompression was conducted followed by dynamic stabilization of the diseased level with an IPDD (X-STOP. Results The average follow-up time was 27.4 months. Visual Analogue Scale and Oswestry Disability Index improved statistically significantly (p Conclusions The described surgical technique using unilateral microdecompression and IPDD insertion is a clinically effective and radiologically viable treatment method for symptoms of spinal stenosis resistant to non-operative treatment.

  9. Magnet sorting algorithms for insertion devices for the Advanced Light Source

    International Nuclear Information System (INIS)

    Humphries, D.; Hoyer, E.; Kincaid, B.; Marks, S.; Schlueter, R.

    1994-01-01

    Insertion devices for the Advanced Light Source (ALS) incorporate up to 3,000 magnet blocks each for pole energization. In order to minimize field errors, these magnets must be measured, sorted and assigned appropriate locations and orientation in the magnetic structures. Sorting must address multiple objectives, including pole excitation and minimization of integrated multipole fields from minor field components in the magnets. This is equivalent to a combinatorial minimization problem with a large configuration space. Multi-stage sorting algorithms use ordering and pairing schemes in conjunction with other combinatorial methods to solve the minimization problem. This paper discusses objective functions, solution algorithms and results of application to magnet block measurement data

  10. Preliminary study of insertion device effect on dynamic aperture using RACETRACK

    International Nuclear Information System (INIS)

    Chae, Yong-chul; Crosbie, E.A.

    1992-01-01

    We studied the effects of an insertion device (ID) on the dynamic aperture using the new version of RACETRACK. We found that the nonlinear effect of the ID is the dominant effect on the dynamic aperture reduction compared to the other multipole errors which exist in the otherwise ideal lattice. The previous study of dynamic aperture was based on the assumption that the effect of the fast oscillating terms in L. Smith's Hamiltonian is small, and hence can be neglected in the simulation. The remarkable agreement between the previous study and the current results using RACETRACK, including all effects of the fast oscillating terms, justified those assumptions at least for the APS ring

  11. Vaginal flora changes on Pap smears after insertion of levonorgestrel-releasing intrauterine device.

    Science.gov (United States)

    Donders, Gilbert G G; Berger, Judith; Heuninckx, Hélène; Bellen, Gert; Cornelis, Ann

    2011-04-01

    The levonorgestrel intrauterine system (LNG-IUS) combines a uterine foreign body and the continuous release of low-dose levonorgestrel for contraception. Its influence on the rate of vulvovaginal infections and flora disturbance is insufficiently known, but important for contraceptive advice in women, especially those who develop recurrent vaginosis or Candida vulvovaginitis. Slides of 286 women who had a Pap smear taken before and 1 to 2 years after placement of a LNG-IUS were blindly reviewed for the presence of abnormal vaginal flora (AVF), bacterial vaginosis (BV), aerobic vaginitis (AV) and Candida vaginitis (CV). Prior to insertion, there were no differences in vaginal flora abnormalities between women using different kinds of contraception. LNG-IUS users did not have different rates of AVF, BV, AV or CV, but the general risk to develop any infection was increased. Uterine bleeding after insertion did not seem to predict a different flora type. We found that Pap smears suggested more vaginal infections after 1 year of LNG-IUS use than prior to insertion of the device. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Design and finite element simulation of vacuum systems for insertion devices in Indus-2 storage ring

    International Nuclear Information System (INIS)

    Yadav, D.P.; Bais, Vijay; Sridhar, R.; Dhimole, Vivek K.; Nitesh, Suthar; Rawal, B.R.; Chogaonkar, Swati

    2015-01-01

    Indus-2 is a 2.5 GeV, 300 mA, Synchrotron Radiation Source (SRS) located at Raja Ramanna Centre for Advanced Technology, Indore. As part of insertion device (ID) development programme two new devices namely, APPLE-2 (Advanced Planar Polarized Light Emitter) type Undulator (also known as U-3 Undulator) and 5 Tesla superconducting wavelength shifter (SWLS) are being developed. APPLE-2 will generate variably polarized synchrotron radiation (SR) required for carrying out magnetic circular dichroism (MCD) and magnetic linear dichroism (MLD) experiments and SWLS will generate synchrotron radiation (SR) with critical photon energy of about 20.8 keV for Energy Dispersive XRD beam line. This paper describes design details and finite element analysis results of various simulations carried out for the vacuum systems of these IDs

  13. An automatic device for sample insertion and extraction to/from reactor irradiation facilities

    International Nuclear Information System (INIS)

    Alloni, L.; Venturelli, A.; Meloni, S.

    1990-01-01

    At the previous European Triga Users Conference in Vienna,a paper was given describing a new handling tool for irradiated samples at the L.E.N.A plant. This tool was the first part of an automatic device for the management of samples to be irradiated in the TRIGA MARK ii reactor and successively extracted and stored. So far sample insertion and extraction to/from irradiation facilities available on reactor top (central thimble,rotatory specimen rack and channel f),has been carried out manually by reactor and health-physics operators using the ''traditional'' fishing pole provided by General Atomic, thus exposing reactor personnel to ''unjustified'' radiation doses. The present paper describes the design and the operation of a new device, a ''robot''type machine,which, remotely operated, takes care of sample insertion into the different irradiation facilities,sample extraction after irradiation and connection to the storage pits already described. The extraction of irradiated sample does not require the presence of reactor personnel on the reactor top and,therefore,radiation doses are strongly reduced. All work from design to construction has been carried out by the personnel of the electronic group of the L.E.N.A plant. (orig.)

  14. The vacuum system for insertion devices at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Trakhtenberg, E.; Gluskin, E.; Den Hartog, P.; Klippert, T.; Wiemerslage, G.; Xu, S.

    1995-01-01

    A vacuum system for the insertion devices at the Advanced Photon Source was designed, and chambers of this design were successfully manufactured and tested. Three different versions of the vacuum chamber have been developed with vertical apertures of 12 mm, 8mm, and 5 mm, respectively. The chambers are fabricated by extruding 6063 aluminum alloy to form a tube with the desired internal shaped and machining the exterior to finish dimensions. The wall thickness of the completed chamber at the beam orbit position is 1 mm. The design utilizes a rigid strongback that limits deflection of the chamber under vacuum despite the thin wall. Chambers with lengths of 2.2m and 5.2 m have been fabricated. Pumping is accomplished by a combination of lumped and distributed non-evaporable getters and ion pumps. An ultimate pressure of 5.1· -11 torr was achieved with the 12-mm vertical aperture prototype. Alignment of the vacuum chamber on its support can be made with a precision of ± 25 μm in the vertical plane, which allows minimum insertion device pole gaps of 14.5 mm, 10.5 mm, and 7.5 mm

  15. High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition.

    Science.gov (United States)

    Schässburger, Kai-Uwe; Paepke, Stefan; Saracco, Ariel; Azavedo, Edward; Ekström, Christina; Wiksell, Hans

    2018-02-01

    Minimally invasive biopsies are a cornerstone of breast cancer management with ultrasound being the preferred guidance modality. New developments in breast cancer management and advances in imaging technologies bring new challenges to current biopsy methodologies. A new biopsy device (NeoNavia® biopsy system, 14 G) was developed. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. A new method of tissue acquisition was designed to achieve a sampling yield higher than standard methodologies. Needle dynamics was assessed on a specifically designed test bed and sampling performance was compared to a Magnum® biopsy instrument (Bard, Covington, GA, USA) in representative tissue models. The histological quality of samples obtained ex-vivo was evaluated. A pneumatic pulse was measured to accelerate the needle to a maximum velocity of 21.2 ± 2.5 m/s on a stroke length of 2.5 mm, achieving significantly higher acceleration, maximum velocity and power than current biopsy devices. Mean weight of samples obtained by the NeoNavia device were 3.5, 4.6, and 4.3 times higher when sampling was performed in turkey breast, calf thymus and swine pancreas, respectively, as compared to samples obtained with the Magnum instrument. Ex-vivo analysis indicates that the method of tissue acquisition has no apparent negative impact on the histopathologic quality of obtained samples. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. Does Low-Field Intraoperative Magnetic Resonance Improve the Results of Endoscopic Pituitary Surgery? Experience of the Implementation of a New Device in a Referral Center.

    Science.gov (United States)

    García, Sergio; Reyes, Luis; Roldán, Pedro; Torales, Jorge; Halperin, Irene; Hanzu, Felicia; Langdon, Cristobal; Alobid, Isam; Enseñat, Joaquim

    2017-06-01

    To assess the contribution of low-field intraoperative magnetic resonance (iMRI) to endoscopic pituitary surgery. We analyzed a prospective series of patients undergoing endoscopic endonasal surgery for pituitary macroadenomas assisted with a low-field iMRI (PoleStarN30, 0.15 T [Medtronic]). Clinical, radiologic, and surgical variables were analyzed and compared with our fully endoscopic historic cohort operated on without iMRI assistance. A bibliographic review of pituitary surgery assisted with iMRI was conducted. Thirty patients (57% female; mean age, 55 years) were prospectively analyzed. The most frequent tumor subtype was nonfunctioning macroadenoma (50%). The average Knosp grade was 2.3 and mean tumor size was 18 mm. Surgical and positioning time were 102 and 47 minutes, respectively. Hospital stay and complication rates were similar to our historical cohort for pituitary surgery. Mean follow-up was 10 months. Complete resection (CR) was achieved in 83% of patients. Seven patients (23%) benefited from iMRI assistance and achieved a CR in their surgeries. All patients except 1 experienced hormonal activity remission. iMRI sensitivity and specificity was 0.8 and 1, respectively. Although not statistically significant, CR rates were globally 11.5% superior in iMRI series compared with our historical cohort. This difference was independent of cavernous sinus invasiveness grade (CR rate increased 12.5% for Knosp grade 0-2 and 8.1% for Knosp grade 3-4). Low-field iMRI is a useful and safe assistance even in advanced surgical techniques such as endoscopy. Its contribution is limited by the intrinsic features of the tumor. Further randomized studies are required to confirm the cost-effectiveness of iMRI in pituitary surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. An active interlock system for the NSLS x-ray ring insertion devices

    International Nuclear Information System (INIS)

    Nawrocky, R.J.; Biscardi, R.; Dabrowski, J.; Flannigan, J.; Ramamoorthy, S.; Rothman, J.; Smith, J.; So, I.; Thomas, M.; Decker, G.

    1991-01-01

    This paper describes the design and operation of an active interlock system which has been installed in the NSLS X-ray electron storage ing to protect the vacuum chamber from thermal damage by mis-steered high power photon beams from insertion devices (IDs). the system employs active beam position detectors to monitor beam motion in the ID straight sections and solid state logic circuitry to ''dump'' the stored beam in the event of a fault condition by interrupting the rf. To ensure a high degree of reliability, redundancy and continuous automatic checking has been incorporated into the design. Overall system integrity is checked periodically with beam at safe levels of beam current. 2 refs., 3 figs

  18. The first photon shutter development for APS insertion device beamline front ends

    International Nuclear Information System (INIS)

    Shu, Deming; Nian, H.L.T.; Wang, Zhibi; Collins, J.T.; Ryding, D.G.; Kuzay, T.M.

    1992-01-01

    One of the most critical components on the Advanced Photon Source (APS) insertion device (ID) beamline front ends is the first photon shutter. It operates in two modes to fully intercept the high total power and high-heat flux ID photon beam in seconds (normal mode) or in less than 100 ms (emergency fast mode). It is designed to operate in ultra high vacuum (UHV). The design incorporates a multi-channel rectangular bar, bent in a ''hockey stick'' configuration, with two-point suspension. The flanged end is an articulated bellows with rolling hinges. The actuation end is a spring-assisted, pneumatic fail-safe flexural pivot type. The coolant (water) channels incorporate brazed copper foam to enhance the heat transfer, a tube technology particular to the APS. The design development, and material aspects, as well as the extensive thermal and vibrational analyses in support of the design, are presented in this paper

  19. Tracking studies of insertion device effects on dynamic aperture in the APS storage ring

    International Nuclear Information System (INIS)

    Chae, Yong-chul; Crosbie, E.A.

    1993-01-01

    We studied the effects of an insertion device (ID) on the dynamic aperture in the 7-GeV Advanced Photon Source (APS) storage ring using the program RACETRACK. We found that the nonlinear effect of the ID is the dominant effect on the dynamic aperture reduction compared to the other multipole errors which exist in the otherwise ideal lattice. The previous study of dynamic aperture was based on the assumption that the effect of the fast oscillating terms in L. Smith's Hamiltonian is small, and hence can be neglected in the simulation. The remarkable agreement between the previous study and the current results using RACETRACK, including all effects of the fast oscillating terms, justified those assumptions at least for the APS ring

  20. Insertion device development in the X13 straight of the NSLS X-Ray Ring

    International Nuclear Information System (INIS)

    Stefan, P.M.; Krinsky, S.; Kao, C.C.; Rakowsky, G.; Singh, O.; Solomon, L.

    1997-01-01

    On the NSLS X-Ray Storage Ring, the X13 straight section and beamline have been used for insertion-device-related R and D since 1990. The authors will describe three important projects: The Prototype Small-Gap Undulator (PSGU), the In-Vacuum Undulator (IVUN), and the Time Varying Elliptically Polarized Wiggler (EPW). The PSGU has successfully operated with a vertical aperture of only 3 mm, with minimal reduction in electron beam lifetime. The EPW has successfully run during regular user operations while switching at either 2 Hz or 100 Hz, with no adverse effects on other experiments. The IVUN project is a collaboration between NSLS and Spring-8, and installation is scheduled for May 1997

  1. Bremsstrahlung scattering calculations for the beam stops and collimators in the APS insertion-device beamlines

    International Nuclear Information System (INIS)

    Job, P.K.; Haeffner, D.R.; Shu, D.

    1994-12-01

    Bremsstrahlung is produced in the APS storage ring by the interaction of positrons with the residual gas molecules in the vacuum chamber of the storage ring. The bremsstrahlung production causes a serious challenge in shielding the insertion-device beamlines because the entire straight section (15 meters) is in the line of sight of the beamline. The radiation emerges in a narrow cone tangential to the beam path with the characteristic emission angle 1/γ, where γ is E/mc 2 which is the ratio of the kinetic energy to the rest mass for the positrons. This high-energy gamma radiation has an approximate 1/E spectrum with the maximum energy extending up to the particle energy (7 GeV for the APS). Bremsstrahlung, being high-energy photons, produces an electromagnetic shower when it encounters the beamline elements. A beamline element not thick enough to fully contain an electromagnetic shower can cause considerable scatter of the high-energy bremsstrahlung radiation. The low-energy component of the bremsstrahlung can also be scattered and create high dose rates in the first-optical and white-beam enclosures. The fully developed electromagnetic shower will have a photon spectrum almost independent of the material. The electromagnetic showers in the high-Z materials can also produce photoneutrons. This note reports the summary of EGS4 calculations performed on bremsstrahlung scattering from different beamline components in a typical APS insertion-device beamline. The related recommendations for shielding are also given. The shielding criterion adopted is a total dose rate of 2.5μSv/h (0.25 mrem/h) at 30 cm from the shield

  2. IUD in first-trimester abortion: immediate intrauterine contraceptive devices insertion vs delayed insertion following the next menstruation bleeding.

    Science.gov (United States)

    Tsikouras, Panagiotis; Vrachnis, Nikolaos; Grapsa, Anastasia; Tsagias, Nikolaos; Pinidis, Petros; Liberis, Anastasios; Ammari, Alexandros; Grapsas, Xenofon; Galazios, Georgios; Liberis, Vasileios

    2014-07-01

    Approximately 21 days after an abortion, ovulation occurs in 50 % of women. Installation of an IUD directly after induced or spontaneous abortion offers immediate contraceptive protection. The purpose of the present study was to weigh up contraceptive safety and adverse reactions of IUD inserted directly after first-trimester abortion under general or paracervical anesthesia as against the fitting of IUD in the days of the next menstrual cycle without anesthesia. During the period May 1987 to October 2010, 73 women (Group A) underwent an immediate post-abortion insertion IUD after a first-trimester spontaneous or induced abortion under general or local paracervical anesthesia and 69 participants (Group B) received IUD during the next menstrual cycle without anesthesia. Questionnaires were completed by all the women of the study with respect to the effects of IUD. The women were examined every 3 months for 1 year after the fitting of the IUD in the out-patient department of the University Obstetrics Gynecological Department of Alexandroupolis, Democritus University of Thrace, Greece. The demographic characteristics of the women of the two groups were similar. The age of the women ranged between 19 and 44 years, while 61.98 % were women with one or two children and 38.02 % were women with three or more children. During the first menstrual cycles, with the exception of vaginal hemorrhages (5 %) and adnexitis (1 %), no serious adverse reactions were noted. During the transvaginal ultrasonography checks in both groups, no observation was made of any dislocation of the IUD, except for two cases in the subgroup of those women with paracervical anesthesia and one case in the women of Group B. As concerns the questionnaire with regard to the women's subjective evaluation of IUD, satisfactory answers were given. There were no differences between the two groups either with respect to the security of the supplied contraceptive methods or to the development of side effects.

  3. A conceptual design of the set-up for solid state spectroscopy with free electron laser and insertion device radiation

    CERN Document Server

    Makhov, V N

    2001-01-01

    The set-up for complex solid state spectroscopy with the use of enhanced properties of radiation from insertion devices and free electron lasers is proposed. Very high flux and pulsed properties of radiation from insertion devices and free electron lasers offer the possibility for the use of such powerful techniques as electron paramagnetic resonance (EPR) and optically detected magnetic resonance (ODMR) for the studies of excited states of electronic excitations or defects in solids. The power density of radiation can become high enough for one more method of exited-state spectroscopy: transient optical absorption spectroscopy. The set-up is supposed to combine the EPR/ODMR spectrometer, i.e. cryostat supplied with superconducting magnet and microwave system, and the optical channels for excitation (by radiation from insertion devices or free electron laser) and detection of luminescence (i.e. primary and secondary monochromators). The set-up can be used both for 'conventional' spectroscopy of solids (reflec...

  4. Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS

    Science.gov (United States)

    Decker, Glenn; Rosenbaum, Gerd; Singh, Om

    2006-11-01

    Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.

  5. Device for inserting and removing electric plug in socket- using remote handling apparatus inside radioactive hot cell

    International Nuclear Information System (INIS)

    Chevallereau, R.; Galmard, Y.

    1994-01-01

    A device for pushing an electric plug into a supply socket inside a radioactive hot cell and for withdrawing the plug after use of the appliance attached to it, comprises a pair of pivotally mounted arms. It can be used inside radioactive hot cells, to insert and put in and put off electric plugs

  6. Review of window and filter requirements for commissioning of the Advanced Photon Source insertion device beamlines

    International Nuclear Information System (INIS)

    Kuzay, T.M.; Wang, Zhibi.

    1994-01-01

    The Advanced Photon Source (APS) is building 16 insertion device (ID) front ends for the first phase of the project. Eleven of these are to be equipped with the APS Undulator A and the other five with a Wiggler-A-type source. The Undulator A front ends are designed to operate in a ''windowless'' mode using an APS-designed differential pump. However, during beamline commissioning and early operations of the storage ring, it is prudent to install windows to ensure storage ring vacuum safety before easing into windowless operation. However, the window designed for this interim period may not meet all the needs of a user's scientific program. In the early phases of the project through commissioning and start of operations, such a window will permit the user to prepare for his program, while allowing both the user and the facility operators to gain experience for safe phasing into eventual windowless operations. In this report, we will present analysis and design options for a variety of windows particularly suited to either the APS Undulator A front ends or as user windows located in the first optics enclosure (FOE)

  7. Latest experiences and future plans on NSLS-II insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, T.; Hidaka, Y.; Kitegi, C.; Hidas, D.; Musardo, M.; Harder, D. A.; Rank, J.; Cappadoro, P.; Fernandes, H.; Corwin, T. [Energy Sciences Directorate, Brookhaven National Laboratory, Upton, NY 11973, U.S.A (United States)

    2016-07-27

    National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.

  8. Active interlock system for high power insertion devices in the x-ray ring

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    In modern synchrotron radiation rings photon beams generated by high power insertion devices (IDs) may be sufficiently intense to cause severe thermal damage to the machine vacuum chamber if mis-steered. Thus when operating a storage ring with the IDs, great care must be exercised to prevent mis-steering of the electron beam orbit. At present, the X-ray ring operates with three IDs, namely two hybrid wigglers (HBW) at X-21 and X-25,a nd a 5-Tesla superconducting wiggler at X-17. All wigglers are located in low-beta straight sections. In the straight sections. In the straight sections, beam orbit may be deflected by as much as ±8 mrad without scraping the chamber wall. For various reasons it was not possible to design the X-ray ring vacuum chamber to be safe under all possible operating conditions, however, the chamber is safe for i < 7 mA, all horizontal beam deflection angles and for vertical angles < ± 2.5 mrad. To protect the machine vacuum chamber from damage due to mis-steered beams, and interlock system has been developed and installed. This system utilizes active beam position detectors which continuously monitor beam motion in each of the ID straight sections and logic circuitry which interrupts the RF and dumps the stored beam in the case of a fault

  9. Anesthesia for left ventricular assist device insertion: a case series and review.

    Science.gov (United States)

    Broussard, David; Donaldson, Emilie; Falterman, Jason; Bates, Michael

    2011-01-01

    From October 2008 to June 2010, a total of 42 patients had the HeartMate II left ventricular assist device inserted surgically at Ochsner Medical Center in New Orleans, LA. A retrospective electronic record review was conducted on this series of patients to analyze elements of perioperative anesthetic care, including general anesthetic care, echocardiographic considerations, and blood product usage. Etomidate was used to induce anesthesia for 34 of 42 patients (81%) in this series, with an average dose of 16.5 mg (±6 mg). The average intraoperative fentanyl dose was 1,318 µg (±631 µg). On average, patients were extubated 91 hours (±72 hours) after arrival to the intensive care unit and left on day 9 (±5 days). The average left ventricular ejection fraction of the patients in this series was 13% (±5%). Sixteen patients were evaluated as having severe right-heart dysfunction preoperatively. Two of 42 patients required surgical closure of echocardiographically identified patent foramen ovale. Twelve of 42 patients underwent surgical correction of tricuspid regurgitation. On average, 3 units (±2.6 units) of fresh frozen plasma were transfused intraoperatively and 10 units postoperatively. Intraoperative red blood cell usage averaged 1.1 units (maximum, 7 units), with an average 9.3 units administered in the first 48 hours postoperatively.

  10. Doppler color flow analysis of the uterine arteries before and after intrauterine device insertion: a prospective study.

    Science.gov (United States)

    de Souza, Marco Aurélio Martins; Geber, Selmo

    2006-02-01

    An intrauterine device (IUD) is one of the most frequently used methods of birth control around the world. Although a relationship between its use and menstrual disorders has been well documented, only a few studies have tried to show whether there are any vascular modifications. The aim of our study was to evaluate the influence of an IUD on uterine artery blood flow using Doppler assessment. A total of 100 patients selected for IUD use were prospectively evaluated with Doppler analysis before and 30 days after insertion. The resistive index (RI) and pulsatility index (PI) were used to evaluate uterine artery vascular resistance. Patients were allocated in 2 groups according to whether they were (group 2) or were not (group 1) lactating. The PI and RI of the patients in groups 1 and 2 before and after IUD insertion were not statistically significantly different (P = .298 and .23). When we compared uterine artery blood flow indices before and after IUD insertion for groups 1 and 2 separately, we observed in group 1 that the mean +/- SD PI values were 2.45 +/- 0.62 and 2.55 +/- 0.55 (P = .38) and the RI values were 0.87 +/- 0.08 and 0.87 +/- 0.06 (P = .88) before and after IUD insertion, respectively. In group 2, the PI values were 2.31 +/- 0.55 and 2.37 +/- 0.69 (P = .68) and the RI values were 0.85 +/- 0.07 and 0.86 +/- 0.07 (P = .44) before and after IUD insertion. Finally, we used the mean blood flow indices of the uterine arteries of all patients to compare the effect of IUD insertion. Results were also not statistically significant when we compared PI and RI before and after IUD insertion. The presence of an IUD does not interfere with the vascular resistance of the uterine arteries that can be shown by Doppler flow assessments 1 month after insertion.

  11. Effect of inserted metal at anode tip on formation of pulsed X-ray emitting zone of plasma focus device

    Science.gov (United States)

    Miremad, Seyed Milad; Shirani Bidabadi, Babak

    2018-04-01

    The effect of the anode's insert material of a plasma focus device on the properties of X-ray emission zone was studied. Inserts were fabricated out of six different materials including aluminum, copper, zinc, tin, tungsten, and lead to cover a wide range of atomic numbers. For each anode's insert material at different gas pressures and different voltages, the shape of X-ray emission zone was recorded by three pinhole cameras, which were installed on sidewall and roof of the chamber of plasma focus device. The results indicated that by changing the gas pressure and the charge voltage of capacitor, the X-ray source of plasma focus emerges with different forms as a concentrated column or conical shape with sharp or cloudy edges. These structures are in the form of a combination of plasma emission and anode-tip emission with different intensities. These observations indicate that the material of the anode-tip especially affects the structure of X-ray emission zone.

  12. Method for reducing x-ray background signals from insertion device x-ray beam position monitors

    Directory of Open Access Journals (Sweden)

    Glenn Decker

    1999-11-01

    Full Text Available A method is described that provides a solution to the long-standing problem of stray radiation-induced signals on photoemission-based x-ray beam position monitors (BPMs located on insertion device x-ray beam lines. The method involves the introduction of a chicane into the accelerator lattice that directs unwanted x radiation away from the photosensitive x-ray BPM blades. This technique has been implemented at the Advanced Photon Source, and experimental confirmation of the technique is provided.

  13. Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

    Science.gov (United States)

    McNeely, Heidi L; Ream, Theresa L; Thrasher, Jodi M; Dziadkowiec, Oliwier; Callahan, Tiffany J

    2018-04-01

    Vascular access in pediatric patients can be challenging even with the currently available technological resources. This nurse-driven research study explored time, cost, and resources for intravenous access to determine if a biomedical device, VeinViewer ® Vision, would facilitate improvements in pediatric access. In addition, this study looked at nurse perceptions of skills and confidence around intravenous insertion and if the use of the VeinViewer ® impacted these perceptions. Literature examining pediatric intravenous access success rates compared with nurse perceived skills and confidence is lacking. Nonblinded randomized control trial of pediatric nurses working in an acute care hospital setting. A preliminary needs assessment solicited feedback from nurses regarding their practice, perceived skills, and confidence with placing peripheral intravenous catheters (PIVs). Due to the results of the preliminary needs assessment, a research study was designed and 40 nurses were recruited to participate. The nurses were randomized into either a VeinViewer ® or standard practice group. Nurse participants placed intravenous catheters on hospitalized pediatric patients using established procedures while tracking data for the study. Needs assessment showed a majority of nurses felt a biomedical device would be helpful in building their intravenous insertion skills and their confidence. The study results did not demonstrate any clinically significant differences between VeinViewer ® use and standard practice for intravenous catheter insertion in pediatric patients for success of placement, number of attempts, or overall cost. In addition, no difference was noted between nurses in either group on perceived skills or confidence with insertion of PIVs. The ongoing need for resources focused on building nurse skills and confidence for PIV insertion was highlighted and organizations should continue to direct efforts toward developing skills and competency for staff that

  14. Cermet insert high voltage holdoff for ceramic/metal vacuum devices

    Science.gov (United States)

    Ierna, William F.

    1987-01-01

    An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

  15. Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices

    Science.gov (United States)

    Ierna, W.F.

    1986-03-11

    An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

  16. A backing device based on an embedded stiffener and retractable insertion tool for thin-film cochlear arrays

    Science.gov (United States)

    Tewari, Radheshyam

    Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based biodegradable and water soluble adhesive, that will help to retract the PET insertion tool after implantation. As a proof-of-concept of sub-system one, a microfabrication process for patterning PLA stiffeners embedded in parylene has been developed. Conventional hot-embossing, mechanical micromachining, and standard cleanroom processes were integrated for patterning fully released and discrete stiffeners coated with parylene. The released embedded stiffeners were thermoformed to demonstrate that imparting perimodiolar shapes to stiffener-embedded arrays will be possible. The developed process when integrated with the array fabrication process will allow fabrication of stiffener-embedded arrays in a single process. As a proof-of-concept of sub-system two, the feasibility of the attaching and detaching mechanism was demonstrated by adhering 1x and 1.5x scale PET tube-based insertion tools and PLA stiffeners embedded in parylene using the copolymer adhesive. The attached devices survived qualitative adhesion tests, thermoforming, and flexing. The viability of the detaching mechanism was tested by aging the assemblies in-vitro in phosphate buffer solution. The average detachment times, 2.6 minutes and 10 minutes

  17. An assessment of the effects of radiation on permanent magnet material in the ALS [Advanced Light Source] insertion devices

    International Nuclear Information System (INIS)

    Hassenzahl, W.V.; Jenkins, T.M.; Namito, Y.; Nelson, W.R.; Swanson, W.P.

    1989-08-01

    Electrons that are lost from the beam during normal operation of a synchrotron radiation source and during a beam dump at the end of a run produce both ionizing radiation and neutrons. This radiation has the potential for damaging sensitive materials, in particular those that need to be very close to the beam. The wigglers and undulators for the Advanced Light Source (ALS) at LBL will use magnetic materials such as the very high performance neodymium-iron-boron, which will be as close as 1 cm away from the electron beam during operation. This material, which is preferred because of its high remanence, is known to be more sensitive to radiation than some other magnetic materials. Simple energy loss estimates and the EGS4 code were used to estimate the radiation levels in the ALS insertion devices in the regions of the magnetic materials. The radiation levels were estimated for both aluminum and stainless steel vacuum chambers to determine if one would provide significantly better shielding. We conclude that Nd-Fe-B can be used in the ALS insertion devices and that there is little difference in the radiation levels for aluminum and stainless vacuum vessels. 8 refs., 7 figs., 1 tab

  18. Some aspects of achieving an ultimate accuracy during insertion device magnetic measurements by a Hall probe

    International Nuclear Information System (INIS)

    Vasserman, I. B.; Xu, J. Z.; Strelnikov, N. O.

    2013-01-01

    An extensive test of a new Senis 2-axis Hall probe was done at the Advanced Photon Source using the Undulator A device and calibration system. This new probe has clear advantages compared with previously used Bell and Sentron Hall probes: very stable zero offset (less than the noise of 0.026 G) and compensated planar Hall effect. It can be used with proper calibration even for first and second field integral measurements. A comparison with reference measurements by long stretched coil shows that the difference in the first field integral measurement results for a 2.4-m-long Undulator A device is between 17 G cm for the best of four Hall probes used for the test and 51 G cm for the worst of them for all gap ranges from 10.5 mm to 150 mm.

  19. Analysis of insertion device magnet measurements for the Advanced Light Source

    International Nuclear Information System (INIS)

    Marks, S.; Humphries, D.; Kincaid, B.M.; Schlueter, R.; Wang, C.

    1993-07-01

    The Advanced Light Source (ALS), which is currently being commissioned at Lawrence Berkeley Laboratory, is a third generation light source designed to produce XUV radiation of unprecedented brightness. To meet the high brightness goal the storage ring has been designed for very small electron beam emittance and the undulators installed in the ALS are built to a high degree of precision. The allowable magnetic field errors are driven by electron beam and radiation requirements. Detailed magnetic measurements and adjustments are performed on each undulator to qualify it for installation in the ALS. The first two ALS undulators, IDA and IDB, have been installed. This paper describes the program of measurements, data analysis, and adjustments carried out for these two devices. Calculations of the radiation spectrum, based upon magnetic measurements, are included. Final field integral distributions are also shown. Good field integral uniformity has been achieved using a novel correction scheme, which is also described

  20. Very low field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Herreros, Quentin

    2013-01-01

    The aim of this thesis is to perform Magnetic Resonance Imaging at very low field (from 1 mT to 10 mT). A new kind of sensor called 'mixed sensor' has been used to achieve a good detectivity at low frequencies. Combining a superconducting loop and a giant magnetoresistance, those detectors have a competitive equivalent field noise compared to existing devices (Tuned coils, SQUIDs and Atomic Magnetometers). They have been combined with flux transformers to increase the coupling between the sample and the sensor. A complete study has been performed to adapt it to mixed sensors and then maximize the gain. This set has been incorporated in an existing small MRI device to test its robustness in real conditions. In parallel, several MRI sequences (GE, SE, FLASH, EPI,...) have been integrated and adapted to very low field requirements. They have been used to perform in-vivo three dimensional imaging and relaxometry studies on well known products to test their reliability. Finally, a larger setup adapted for full-head imaging has been designed and built to perform images on a larger working volume. (author) [fr

  1. Latest experience on insertion devices at the National Synchrotron Light Source-II

    International Nuclear Information System (INIS)

    Tanabe, Toshiya; Cappadoro, Peter; Corwin, Todd

    2016-01-01

    National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy with the horizontal emittance of the electron beam being 0.9 nm.rad. Nine In-Vacuum Undulators (IVUs) are utilized at the NSLS-II as of February 2016. All IVUs have a unique side window derived from the experience from the CHESS facility in Cornell University. An R and D activity called 'Vacuum Seal Test' was conducted to ensure the viability of aluminum wire seal. Another R and D activity to develop a measurement system for Cryogenic Permanent Magnet Undulator (CPMU) was also performed. Other in-air devices, namely damping wigglers (DWs) and elliptically polarizing undulators (EPUs) utilize extruded aluminum chambers with Non-Evaporable Getter (NEG) coating. The beam-based integral estimates were obtained from the virtual kicks at the upstream and downstream of the undulator that best fit the measured orbit distortion in a model lattice with Tracy. In some cases, there are fairly large discrepancies between magnetic measurement data and observed integrals by the beam. Beam studies were carried out to explain the discrepancies mentioned earlier. The latest experiences on ID development and commissioning are discussed in conjunction with related activities in the world. (author)

  2. Comparing performance of mothers using simplified mid-upper arm circumference (MUAC) classification devices with an improved MUAC insertion tape in Isiolo County, Kenya

    DEFF Research Database (Denmark)

    Grant, Angeline; Njiru, James; Okoth, Edgar

    2018-01-01

    to a "gold standard" classification (the mean of three measurements taken by a research assistant using the MUAC insertion tape).  Results: The sensitivity of mother/caregiver classifications was high for all devices (>93% for severe acute malnutrition (SAM), defined by MUAC 90% for global...... acute malnutrition (GAM), defined by MUAC classification was higher using the MUAC insertion tape (100% sensitivity for SAM and 99% sensitivity for GAM) than using "Click-MUAC" devices. Younden's J for SAM classification, and sensitivity for GAM......Background: A novel approach for improving community case-detection of acute malnutrition involves mothers/caregivers screening their children for acute malnutrition using a mid-upper arm circumference (MUAC) insertion tape. The objective of this study was to test three simple MUAC classification...

  3. Measurement of the radiation incident on ALS NdFeB permanent magnet insertion device structures and a determination of their lifetime

    International Nuclear Information System (INIS)

    Krebs, G.F.; Holmes, M.

    1997-05-01

    Measurements of the radiation incident on ALS insertion device NdFeB permanent magnet structures were carried out using thermoluminescence dosimeters. A plastic scintillator gamma telescope was utilized to unravel the various contributions to the integrated dose. Magnet lifetimes were calculated for various operational conditions

  4. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  5. Incidence of thrombosis in children with tunneled central venous access devices versus peripherally inserted central catheters (PICCs).

    Science.gov (United States)

    Kanin, Maralee; Young, Guy

    2013-11-01

    The recent proliferation of deep vein thrombosis in children has been attributed to the increased use of central venous catheters, specifically tunneled lines and peripherally inserted central catheters. A formal comparison of the incidence rate for deep vein thrombosis between tunneled lines and peripherally inserted central catheters has not been undertaken. Children inclusion. Data were extracted from the hospital discharge database which includes data on all procedures and up to 20 diagnoses per admission. Diagnoses and procedures were identified by International Classification of Disease, Ninth Revision coding. Patients were excluded if they received more than one central line. Data collected included type of central line, deep vein thrombosis event, and underlying medical illnesses classified according to chronic complex conditions. Over the seven year study period there was an overall rate of 73 deep vein thromboses per 10,000 hospital discharges. Of the 6915 eligible subjects, 181 had a deep vein thrombosis for an overall incidence rate of 2.6%. There were 152 thrombi (2.6%) in subjects with peripherally inserted central catheters and 29 thrombi (3.1%) in subjects with tunneled lines [OR=.83 (0.55, 1.29), p=0.38]. Despite the relative ease and simplicity of use of peripherally inserted central catheters leading to a substantial rise in their use, this study demonstrates that such lines pose a substantial risk for venous thrombosis and no difference in incidence was detected between such lines and tunneled lines. © 2013.

  6. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  7. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  8. Inaccuracy of transthoracic echocardiography for the identification of right-sided vegetation in patients with no history of intravenous drug abuse or cardiac device insertion.

    Science.gov (United States)

    Xie, Jiang; Liu, Shuang; Yang, Jinghua; Xu, Jie; Zhu, Guangfa

    2014-06-01

    The use of transthoracic echocardiography (TTE) to identify right-sided infective endocarditis (RSIE) vegetation is controversial. Data are scarce for patients with no history of intravenous drug abuse (IVDA) or cardiac device insertion. This study analysed the consistency of presurgical echocardiographic results with surgical findings for vegetation identification, and the factors that influence accuracy of echocardiography. This retrospective trial divided infective endocarditis (IE) patients into three subgroups according to the results of their presurgical TTE: left-sided native IE (LSNIE), left-sided prosthetic valve IE (LSPIE) and RSIE. The accuracy of TTE was tested by comparing vegetation (number and location), detected presurgery by TTE, with actual findings during surgery. In total, 416 patients were analysed, 322 with LSNIE, 31 with LSPIE and 63 with RSIE. Consistency between TTE findings and surgical results was lower in the RSIE group compared with the LSPIE and LSNIE groups. Consistency was lowered by the presence of vegetation in multiple locations and atypical distribution--both of which were increased in the RSIE group. The chance of vegetation in both sides of the heart rose with increased numbers of vegetation locations in RSIE patients. A high proportion of RSIE patients had congenital heart defects, mostly ventricular septal defects. TTE may be unsuitable for RSIE patients with no history of IVDA or cardiac device insertion, because multifocal and atypically distributed vegetation may influence detection accuracy. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Smart x-ray beam position monitor system using artificial intelligence methods for the advanced photon source insertion-device beamlines

    International Nuclear Information System (INIS)

    Shu, D.; Ding, H.; Barraza, J.; Kuzay, T.M.; Haeffner, D.; Ramanathan, M.

    1997-09-01

    At the Advanced Photon Source (APS), each insertion device (ID) beamline front-end has two XBPMs to monitor the X-ray beam position for both that vertical and horizontal directions. Performance challenges for a conventional photoemission type X-ray beam position monitor (XBPM) during operations are contamination of the signal from the neighboring bending magnet sources and the sensitivity of the XBPM to the insertion device (ID) gap variations. Problems are exacerbated because users change the ID gap during their operations, and hence the percentage level of the contamination in the front end XBPM signals varies. A smart XBPM system with a high speed digital signal processor has been built at the Advanced Photon Source for the ID beamline front ends. The new version of the software, which uses an artificial intelligence method, provides a self learning and self-calibration capability to the smart XBPM system. The structure of and recent test results with the system are presented in this paper

  10. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    Science.gov (United States)

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  11. Comparison of outcomes at 6 weeks following postpartum intrauterine contraceptive device insertions by doctors and nurses in India: a case–control study☆☆☆

    Science.gov (United States)

    Yadav, Vivek; Balasubramaniam, Sudharsanam; Das, Saswati; Srivastava, Ashish; Srivastava, Ashish; Kumar, Somesh; Sood, Bulbul

    2016-01-01

    Objective As part of a strategy to revitalize postpartum family planning services, Government of India revised its policy in 2013 to permit trained nurses and midwives to insert postpartum intrauterine contraceptive devices (PPIUCDs). This study compares two key outcomes of PPIUCD insertions — expulsion and infection — for physicians and nurses/midwives to generate evidence for task sharing. Study design We analyzed secondary data from the PPIUCD program in seven states using a case–control study design. We included facilities where both doctors and nurses/midwives performed PPIUCD insertions and where five or more cases of expulsion and/or infection were reported during the study period (January–December 2013). For each case of expulsion and infection, we identified a time-matched control who received a PPIUCD at the same facility and had no complaints. We performed a multiple logistic regression analysis focusing on provider cadre while controlling for potential confounding factors. Results In 137 facilities, 792 expulsion and 382 infection cases were matched with 1041 controls. Provider type was not significantly associated with either expulsion [odds ratio (OR) 1.84; 95% confidence interval (CI): 0.82–4.12] or infection (OR 0.73; 95% CI: 0.39–1.37). Compared with centralized training, odds of expulsion were higher for onsite (OR 2.32, 95% CI: 1.86–2.89) and on-the-job training (OR 1.23, 95% CI: 1.11–1.36), but odds of infection were lower for onsite (OR 0.45, 95% CI: 0.27–0.75) and on-the-job training (OR 0.31, 95% CI: 0.25–0.37). Conclusion Trained nurses and midwives who conduct deliveries at public health facilities can perform PPIUCD insertions as safely as physicians. Implications Institutional deliveries are increasing in India, but most normal vaginal deliveries at public health facilities are attended by nurses and midwives due to a shortage of physicians. Task sharing with nurses and midwives can increase women's access to and the

  12. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  13. Dedicated low-field MRI in mice

    International Nuclear Information System (INIS)

    Choquet, P; Breton, E; Goetz, C; Constantinesco, A; Marin, C

    2009-01-01

    The rationale of this work is to point out the relevance of in vivo MR images of mice obtained using a dedicated low-field system. For this purpose a small 0.1 T water-cooled electro-magnet and solenoidal radio frequency (RF) transmit-receive coils were used. All MR images were acquired in three-dimensional (3D) mode. An isolation cell was designed allowing easy placement of the RF coils and simple delivery of gaseous anesthesia as well as warming of the animal. Images with and without contrast agent were obtained in total acquisition times on the order of half an hour to four hours on normal mice as well as on animals bearing tumors. Typical in plane pixel dimensions range from 200 x 200 to 500 x 500 μm 2 with slice thicknesses ranging between 0.65 and 1.50 mm. This work shows that, besides light installation and low cost, dedicated low-field MR systems are suitable for small rodents imaging, opening this technique even to small research units.

  14. Dedicated low-field MRI in mice

    Science.gov (United States)

    Choquet, P.; Breton, E.; Goetz, C.; Marin, C.; Constantinesco, A.

    2009-09-01

    The rationale of this work is to point out the relevance of in vivo MR images of mice obtained using a dedicated low-field system. For this purpose a small 0.1 T water-cooled electro-magnet and solenoidal radio frequency (RF) transmit-receive coils were used. All MR images were acquired in three-dimensional (3D) mode. An isolation cell was designed allowing easy placement of the RF coils and simple delivery of gaseous anesthesia as well as warming of the animal. Images with and without contrast agent were obtained in total acquisition times on the order of half an hour to four hours on normal mice as well as on animals bearing tumors. Typical in plane pixel dimensions range from 200 × 200 to 500 × 500 µm2 with slice thicknesses ranging between 0.65 and 1.50 mm. This work shows that, besides light installation and low cost, dedicated low-field MR systems are suitable for small rodents imaging, opening this technique even to small research units.

  15. Fuel assembly insertion system

    International Nuclear Information System (INIS)

    Barkhurst, D.J.

    1987-01-01

    This patent describes a nuclear reactor facility having fuel bundles: a system for the insertion of a fuel bundle into a position where vertically arranged fuel bundles surround and are adjacent the system comprising, in combination, separate and individual centering devices secured to and disposed on top of each fuel bundle adjacent the position. Each such centering device has a generally box-like cap configuration on the upper end of each fuel bundle and includes: a top wall; first and second side walls, each secured along and upper edge to the top wall; a rear plate attached along opposite vertical edges to the first and second side walls; a front inclined wall joined along an upper edge to the top to the wall and attached along opposite vertical edges first and second side walls; pad means secured to the lower edge of the first and second side walls, the front inclined wall and the rear plate for mounting each centering device on top of an associated fuel bundle; pin means carried by at least two of the pad means engageable with an associated aperature for locating and laterally fixing each centering device on top of its respective fuel bundle. Each front inclined wall of each of the centering devices is orientated on top of its respective fuel bundle to slope upwardly and away from the position where upon downward insertion of a fuel bundle any contact between the lower end of the fuel bundle inserted with a front inclined wall of a centering device will laterally deflect the fuel bundle. Each centering device further includes a central socket means secured to the top wall, and an elongated handling pole pivotally attached to the socket

  16. Preliminary thermo-mechanical analysis of the second phase photon shutters for insertion device beamline front ends at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Nian, H.L.T.; Sheng, I.C.A.; Kuzay, T.M.

    1993-01-01

    The photon shutters (PS) on the insertion device front end of the beamlines at the Advanced Photon Source (APS) are designed to fully intercept powerful 7-GeV undulator radiation. Traditional materials (oxygen-free copper and Glidcop) are used in their construction. Initially, the APS proposes to operate the storage ring at 100 mA. In later phases of operation, the APS will operate the storage ring at 300 mA. The heat flux from the undulators is enormous. For example, in the later phase of the project, the first photon shutter (PS1) placed at a distance of 17 m from the Undulator A source will be subjected to 1400 W/mm 2 at normal incidence with a total power of 11.4 kW. The PS uses an enhanced heat transfer mechanism developed at Argonne National Laboratory, which increases the convective heat transfer coefficient to about 3 W/cm 2 · degrees C with single phase water as the coolant. To be able to handle the expected three-fold increase in the intense heat flux, some low-Z materials (such as beryllium or graphite), which can absorb the x-rays through their thickness, are now considered as the facing material on the absorber base plate of the PS. Our analysis of PSI indicates that the face plate made of either graphite or beryllium retains its integrity in most of the cases. The maximum effective stress of the absorber plate (made of annealed OFHC) exceeds the yield strength (50 MPa) except in the case of an absorber with a 10-mm graphite face plate

  17. Low-field mobility and carrier transport mechanism transition in nanoscale MOSFETs

    International Nuclear Information System (INIS)

    Liu Hongwei; Wang Runsheng; Huang Ru; Zhang Xing

    2010-01-01

    This paper extends the flux scattering method to study the carrier transport property in nanoscale MOSFETs with special emphasis on the low-field mobility and the transport mechanism transition. A unified analytical expression for the low-field mobility is proposed, which covers the entire regime from drift-diffusion transport to quasi-ballistic transport in 1-D, 2-D and 3-D MOSFETs. Two key parameters, namely the long-channel low-field mobility (μ 0 ) and the low-field mean free path (λ 0 ), are obtained from the experimental data, and the transport mechanism transition in MOSFETs is further discussed both experimentally and theoretically. Our work shows that λ 0 is available to characterize the inherent transition of the carrier transport mechanism rather than the low-field mobility. The mobility reduces in the MOSFET with the shrinking of the channel length; however, λ 0 is nearly a constant, and λ 0 can be used as the 'entry criterion' to determine whether the device begins to operate under quasi-ballistic transport to some extent. (semiconductor devices)

  18. Spherical torus, compact fusion at low field

    International Nuclear Information System (INIS)

    Peng, Y.K.M.

    1985-02-01

    A spherical torus is obtained by retaining only the indispensable components on the inboard side of a tokamak plasma, such as a cooled, normal conductor that carries current to produce a toroidal magnetic field. The resulting device features an exceptionally small aspect ratio (ranging from below 2 to about 1.3), a naturally elongated D-shaped plasma cross section, and ramp-up of the plasma current primarily by noninductive means. As a result of the favorable dependence of the tokamak plasma behavior to decreasing aspect ratio, a spherical torus is projected to have small size, high beta, and modest field. Assuming Mirnov confinement scaling, an ignition spherical torus at a field of 2 T features a major radius of 1.5 m, a minor radius of 1.0 m, a plasma current of 14 MA, comparable toroidal and poloidal field coil currents, an average beta of 24%, and a fusion power of 50 MW. At 2 T, a Q = 1 spherical torus will have a major radius of 0.8 m, a minor radius of 0.5 m, and a fusion power of a few megawatts

  19. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images

    NARCIS (Netherlands)

    Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2015-01-01

    Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces

  20. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images

    NARCIS (Netherlands)

    Shahriari, Navid; Hekman, Edsko E.G.; Oudkerk, Matthijs; Misra, Sarthak

    2015-01-01

    Purpose Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection

  1. Insertion of a pentacene layer into the gold/poly(methyl methacrylate)/heavily doped p-type Si/indium device leading to the modulation of resistive switching characteristics

    Science.gov (United States)

    Hung, Cheng-Chun; Lin, Yow-Jon

    2018-01-01

    In order to get a physical insight into the pentacene interlayer-modulated resistive switching (RS) characteristics, the Au/pentacene/poly(methyl methacrylate) (PMMA)/heavily doped p-type Si (p+-Si)/In and Au/PMMA/p+-Si/In devices are fabricated and the device performance is provided. The Au/pentacene/PMMA/p+-Si/In device shows RS behavior, whereas the Au/PMMA/p+-Si/In device exhibits the set/reset-free hysteresis current-voltage characteristics. The insertion of a pentacene layer is a noticeable contribution to the RS characteristic. This is because of the occurrence of carrier accumulation/depletion in the pentacene interlayer. The transition from carrier depletion to carrier accumulation (carrier accumulation to carrier depletion) in pentacene occurring under negative (positive) voltage induces the process of set (reset). The switching conduction mechanism is primarily described as space charge limited conduction according to the electrical transport properties measurement. The concept of a pentacene/PMMA heterostructure opens a promising direction for organic memory devices.

  2. Ultra-low field MRI food inspection system prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kawagoe, Satoshi, E-mail: s133413@edu.tut.ac.jp; Toyota, Hirotomo; Hatta, Junichi; Ariyoshi, Seiichiro; Tanaka, Saburo, E-mail: tanakas@ens.tut.ac.jp

    2016-11-15

    Highlights: • We have developed a ULF-MRI system using HTS-SQUID for food inspection. • We developed a compact magnetically shielded box to attenuate environmental noise. • The 2D-MR image was reconstructed from the grid processing data using 2D-FFT method. • The 2D-MR images of a disk-shaped and a multiple cell water sample were obtained. • The results showed the possibility of applying the ULF-MRI system to food inspection. - Abstract: We develop an ultra-low field (ULF) magnetic resonance imaging (MRI) system using a high-temperature superconducting quantum interference device (HTS-SQUID) for food inspection. A two-dimensional (2D)-MR image is reconstructed from the grid processing raw data using the 2D fast Fourier transform method. In a previous study, we combined an LC resonator with the ULF-MRI system to improve the detection area of the HTS-SQUID. The sensitivity was improved, but since the experiments were performed in a semi-open magnetically shielded room (MSR), external noise was a problem. In this study, we develop a compact magnetically shielded box (CMSB), which has a small open window for transfer of a pre-polarized sample. Experiments were performed in the CMSB and 2D-MR images were compared with images taken in the semi-open MSR. A clear image of a disk-shaped water sample is obtained, with an outer dimension closer to that of the real sample than in the image taken in the semi-open MSR. Furthermore, the 2D-MR image of a multiple cell water sample is clearly reconstructed. These results show the applicability of the ULF-MRI system in food inspection.

  3. Frameless Stereotactic Insertion of Viewsite Brain Access System with Microscope-Mounted Tracking Device for Resection of Deep Brain Lesions: Technical Report.

    Science.gov (United States)

    White, Tim; Chakraborty, Shamik; Lall, Rohan; Fanous, Andrew A; Boockvar, John; Langer, David J

    2017-02-04

    The surgical management of deep brain tumors is often challenging due to the limitations of stereotactic needle biopsies and the morbidity associated with transcortical approaches. We present a novel microscopic navigational technique utilizing the Viewsite Brain Access System (VBAS) (Vycor Medical, Boca Raton, FL, USA) for resection of a deep parietal periventricular high-grade glioma as well as another glioma and a cavernoma with no related morbidity. The approach utilized a navigational tracker mounted on a microscope, which was set to the desired trajectory and depth. It allowed gentle continuous insertion of the VBAS directly to a deep lesion under continuous microscopic visualization, increasing safety by obviating the need to look up from the microscope and thus avoiding loss of trajectory. This technique has broad value for the resection of a variety of deep brain lesions.

  4. Short-term and long-term outcome of radiological-guided insertion of central venous access port devices implanted at the forearm: a retrospective monocenter analysis in 1704 patients

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz; Borgmeyer, Sebastian; Gaa, Jochen; Meier, Reinhard; Berger, Hermann [Technische Universitaet Muenchen, Division of Interventional Radiology, Department of Radiology, Klinikum Rechts der Isar, Muenchen (Germany); Haller, Bernhard [Technische Universitaet Muenchen, Department of Medical Statistics and Epidemiology, Klinikum Rechts der Isar, Munich (Germany); Jansen, Heike; Kiechle, Marion; Ettl, Johannes [Technische Universitaet Muenchen, Department of Obstetrics and Gynecology, Klinikum Rechts der Isar, Munich (Germany)

    2014-09-20

    The objectives are to analyze the technical success rate as well as the short-term and long-term complications of totally implantable venous access ports (TIVAPs) at the forearm. Retrospective analysis of 1,704 consecutively implanted TIVAPs was performed. Primary endpoints were defined as technical success rate, clinical outcome, device service interval, and rates of major complications. Minor complications not requiring port explantation were defined as secondary endpoints. The technical success rate was 99.2 % with no major complications. During follow-up, a total of 643,200 catheter-days were documented, the mean device service interval was 380.6 days/patient. A total of 243 complications (14.4 %) in 226 patients were observed (0.4/1000 catheter-days), in 140 patients (8.3 %) the port device had to be explanted. Disconnection between the port device and the catheter (1.6 %) was more frequent than fracture (0.8 %) and leakage (0.6 %) of the catheter, which occurred more frequently when the catheter was inserted via the cephalic versus the brachial vein. TIVAP implantation at the forearm is a simple and safe procedure with a low rate of early and late complications. (orig.)

  5. Low-Field Magnetic Resonance Imaging of Canine Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Z. Adamiak* and M. Jaskólska and A. Pomianowski1

    2012-01-01

    Full Text Available The aim of presented study was to evaluate selected surface spine coil, and low-field magnetic resonance (MR selected sequences in diagnosing hydrocephalus in dogs. This paper discusses 19 dogs (14 canine patients with hydrocephalus and 5 healthy dogs, of five breeds, subjected to low-field magnetic resonance imaging (MRI of hydrocephalus. Area of the lateral ventricles and brain were examined in dogs with hydrocephalus using low-field MRI (at 0.25 Tesla. The MRI of FSE REL, SE, FLAIR, STIR, 3D HYCE, T3DT1, GE STIR 3D and 3D SHARC sequences with an indication of the most effective sequences are described. Additionally, coils for MR were compared, and models for infusion anesthesia were described. As a result of performed study all estimated sequences were diagnostically useful. However, spinal coil No. 2 (ESAOTE was the most optimal for examining and positioning the cranium.

  6. Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma

    Directory of Open Access Journals (Sweden)

    Manuel Diaz-Llopis

    2010-05-01

    Full Text Available Manuel Diaz-Llopis1,2,3, David Salom1,3, Salvador García-Delpech1,2,3, Patricia Udaondo1,3, Jose Maria Millan3,5, J Fernando Arevalo61Department of Ophthalmology, La Fe University Hospital of Valencia, Valencia, Spain; 2Department of Ophthalmology of the Valencia University, Valencia, Spain; 3Biomedical Network Research Centre on Rare Diseases (CIBERER, Valencia, Spain; 4Catholic University San Vicente Martir, Valencia, Spain; 5Department of Genetics, La Fe University Hospital of Valencia, Valencia, Spain; 6Clinica Oftalmologica Centro Caracas, Retina and VItreous Service, Caracas, DC, VenezuelaPurpose: To evaluate the efficacy and safety of the pars plana clip (PPC in the Ahmed valve tube inserted via the pars plana in patients with secondary refractory glaucomas.Methods: Prospective and interventional case series that included 10 patients with secondary refractory glaucoma. The pars plana vitrectomy and the implant of the modified tube were performed during the same surgery. Control of intraocular pressure (IOP and the development of intra- and postoperative complications were evaluated during the follow-up.Results: Follow-up time was twelve months in all the patients. Control of IOP was achieved in 90% of patients, and 70% needed no antiglaucoma treatment. The complications that occurred were transient hypotony in three cases, choroidal detachment in two cases, and one case of intraocular hemorrhage. No case of tube extrusion or tube kink was observed.Conclusions: Our data suggests that implantation of the Ahmed tube modified with the PPC via the pars plana is safe and effective in patients with secondary refractory glaucomas. Keywords: pars plana clip, Ahmed valve, refractory glaucoma, pars plana vitrectomy

  7. Method and device for detecting impact events on a security barrier which includes a hollow rebar allowing insertion and removal of an optical fiber

    Science.gov (United States)

    Pies, Ross E.

    2016-03-29

    A method and device for the detection of impact events on a security barrier. A hollow rebar is farmed within a security barrier, whereby the hollow rebar is completely surrounded by the security barrier. An optical fiber passes through the interior of the hollow rebar. An optical transmitter and an optical receiver are both optically connected to the optical fiber and connected to optical electronics. The optical electronics are configured to provide notification upon the detection of an impact event at the security barrier based on the detection of disturbances within the optical fiber.

  8. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  9. Improved organic light-emitting device with tris-(8-hydroxyquinoline) aluminium inserted between hole-injection layer and hole-transporting layer

    Energy Technology Data Exchange (ETDEWEB)

    Divayana, Y [School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798, Singapore (Singapore); Sun, X W [School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798, Singapore (Singapore); Chen, B J [School of Electrical and Electronic Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798, Singapore (Singapore); Sarma, K R [Aerospace Electronic Systems, Honeywell, 21111 N 19th Avenue, Phoenix, AZ 85027 (United States)

    2007-01-07

    A layer of tris-(8-hydroxyquinoline) aluminium (Alq{sub 3}), which is normally used as an electron-transporting and emissive layer, was incorporated between the hole-transporting layer and the hole-injection layer to balance the electron-hole injection. The Alq{sub 3} layer performed to block the hole current which is a majority carrier in a typical organic light-emitting device. An increase in current efficiency by almost 30%, from 3.1 to 4.0 cd A{sup -1}, with a minimum voltage shift was achieved with a 2 nm Alq{sub 3} layer as a hole-blocking layer. A reduction in HTL thickness was observed to reduce the efficiency due to electron leakage to the HIL, whereby an inefficient exciplex emission was observed.

  10. A Randomized Cadaver Study Comparing First-Attempt Success Between Tibial and Humeral Intraosseous Insertions Using NIO Device by Paramedics: A Preliminary Investigation.

    Science.gov (United States)

    Szarpak, Lukasz; Truszewski, Zenon; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Adamczyk, Piotr; Czyzewski, Lukasz

    2016-05-01

    Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. clinicaltrials.gov Identifier: NCT02700867.

  11. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  12. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  13. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model insertion in the immediate postoperative period

    Directory of Open Access Journals (Sweden)

    Ganesh S

    2016-01-01

    Full Text Available Sri Ganesh, Sheetal BrarDepartment of Phaco and Refractive Surgeries, Nethradhama Superspeciality Eye Hospital, Bangalore, IndiaPurpose: To compare the effect of two ocular viscosurgical devices (OVDs on intraocular pressure (IOP and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model implantation.Methods: A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes.Results: Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00. Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05 for both the groups.Conclusion: The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model.Keywords: OVD, hyaluronic acid, ICL, V4c, IOP spikes

  14. Application of low field intensity joint MRI in ankle injury

    International Nuclear Information System (INIS)

    Zhang Zhenyu; Wang Wei

    2011-01-01

    Objective: To observe the diagnostic value of the low field intensity joint magnetic resonance imaging (MRI) in traumatic ankles. Methods: Through a retrospective examination and collection of 50 cases with complete information and checked by arthroscope or/and operated from Jan 2007 to Jun 2010, the diagnostic value ligament of the ankle joint, bone contusion,occult fracture, talus cartilage, and tendon could be evaluated. Cases of fracture for which could be diagnosed by X rays and CT were not included in this research. Results: The special low field intensity joint MRI had a high diagnostic sensitivity of 88.9% to ligamentum talofibulare anterius, but was only 50% sensitive to ligamentum calcaneofibulare. Its sensitivity to injury of ligamentum deltoideum and distal tibiofibular syndesmosis was up to 100%. Tendon injury, bone contusion and occult fracture could be exactly diagnosed. Its total sensitivity on talus cartilage traumatism was 70.6%. Its diagnosis sensitivity to talus cartilage traumatism at the 3rd-5th period by Mintz was 90%, with a lower one of 42.9% at the 1st-2nd period. Talus cartilage traumatism could be exactly predicted by osseous tissue dropsy below cartilage. Conclusion: The special low field intensity joint MRI is highly applicable to the diagnosis on ankle joint traumatism and facilitates clinical treatment. (authors)

  15. Improving Magnet Designs With High and Low Field Regions

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian Robert Haffenden; Smith, Anders

    2011-01-01

    A general scheme for increasing the difference in magnetic flux density between a high and a low magnetic field region by removing unnecessary magnet material is presented. This is important in, e.g., magnetic refrigeration where magnet arrays have to deliver high field regions in close proximity...... to low field regions. Also, a general way to replace magnet material with a high permeability soft magnetic material where appropriate is discussed. As an example, these schemes are applied to a two dimensional concentric Halbach cylinder design resulting in a reduction of the amount of magnet material...

  16. Low-field susceptibilities of rare earth spin glass alloys

    International Nuclear Information System (INIS)

    Sarkissian, B.V.B.

    1977-01-01

    Static susceptibility in various applied fields and AC susceptibility data on Sc 13% Gd and Sc 4.5% Tb spin glass alloys are reported. The data show that the sharp peak at the freezing temperature, Tsub(g), normally observed in the low-field susceptibility of spin glasses containing 3d magnetic impurities is observed here in the case of Gd, which is an S state solute, but not for Tb. On the contrary, for the Sc-Tb alloy a rather rounded maximum is observed which becomes slightly sharper with increasing applied magnetic fields. (author)

  17. Spinal meningeal cyst: analysis with low-field MRI

    International Nuclear Information System (INIS)

    Wu Hongzhou; Chen Yejia; Chen Ronghua; Chen Yanping

    2010-01-01

    Objective: To analyze the characteristics of spinal meningeal cyst in low-field MRI and to discuss its classification, subtype, clinical presentation, and differential diagnosis. Methods: Forty-two patients (20 male, 22 female) were examined with sagittal T 1 -and T 2 -, axial T 2 -weighted MR imaging. Twelve patients were also examined with contrast-enhanced MRI. Results: The cysts were classified using Nakors' classification as type Ia extradural meningeal cysts (4 patients), type Ib sacral meningeal cysts (32), type II extradural meningeal cysts with spinal nerve root fibers (4), and type III spinal intradural meningeal cysts (2). All 42 spinal meningeal cysts had well-defined boundaries with low T 1 and high T 2 signal intensities similar to cerebral spinal fluid. In type Ia, the lesions were often on the dorsum of mid-lower thoracic spinal cord compressing the spinal cord and displacing the extradural fat. In type Ib, the lesions were in the sacral canal with fat plane between the cyst and dural sac. In type II, the lesions contained nerve roots and were lateral to the dural sac. In type III, the lesions were often on the dorsum of spinal cord compressing and displacing the spinal cord anteriorly. Conclusion: Low-field MRI can clearly display the spinal meningeal cyst. Types Ia and Ib spinal meningeal cysts had typical features and can be easily diagnosed. Types II and III should be differentiated from cystic schwannomas and enterogenous cysts, respectively. (authors)

  18. Insertion Modeling and Its Applications

    OpenAIRE

    Alexander Letichevsky; Oleksandr Letychevskyi; Vladimir Peschanenko

    2016-01-01

    The paper relates to the theoretical and practical aspects of insertion modeling. Insertion modeling is a theory of agents and environments interaction where an environment is considered as agent with a special insertion function. The main notions of insertion modeling are presented. Insertion Modeling System is described as a tool for development of different kinds of insertion machines. The research and industrial applications of Insertion Modeling System are presented.

  19. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  20. Low-field magnetization process and complex permeability of ...

    Indian Academy of Sciences (India)

    Amorphous metallic materials hold a prominent position ... elements in magnetic sensors and/or transducer devices. Recently ... interest in the development of biphase wires consisting of a .... netic and superconducting materials (ed.) ...

  1. In situ viscosity of oil sands using low field NMR

    International Nuclear Information System (INIS)

    Bryan, J.; Moon, D.; Kantzas, A.

    2005-01-01

    In heavy oil and bitumen reservoirs, oil viscosity is a vital piece of information that will have great bearing on the chosen EOR scheme and the recovery expected. Prediction of in situ viscosity with a logging tool would he very beneficial in reservoir characterization and exploitation design. Low field NMR is a technology that has shown great potential as a tool for characterizing hydrocarbon properties in heavy oil and bitumen reservoirs. An oil viscosity correlation has previously been developed that is capable of providing order of magnitude viscosity estimates for a wide range of oils taken from various fields in Alberta. This paper presents tuning procedures to improve the NMR predictions for different viscosity ranges, and extends the NMR viscosity model to in situ heavy oil in unconsolidated sands. The results of this work show that the NMR oil peak can be de-convoluted from the in situ signals of the oil and water, and the bulk viscosity correlation that was developed for bulk oils can he applied to predict the in situ oil viscosity. These results can be translated to an NMR logging tool algorithm, allowing for in situ measurements of oil viscosity at the proper reservoir conditions. (author)

  2. Evaluation of PHB nanocomposite by low field NMR

    International Nuclear Information System (INIS)

    Silva, Mariana Bruno Rocha e; Tavares, Maria Ines Bruno

    2009-01-01

    Poly(3-hydroxybutyrate) (PHB) based on nanocomposites containing different amounts of a commercial organically modified clay (viscogel B8) were prepared employing solution intercalation method. The relationship among the processing conditions; molecular structure and intermolecular interaction, between both nanocomposite components, were investigated using a nuclear magnetic resonance (NMR), as a part of characterization methodology, which has been used by Tavares et al. It involves the proton spin-lattice relaxation time, T1 H, by solid state nuclear magnetic resonance, employing low field NMR. X-ray diffraction was also employed because it is a conventional technique, generally used to obtain the first information on nanocomposite formation. Changes in PHB crystallinity were observed after the organophilic nanoclay had been incorporated in the polymer matrix. These changes, in the microstructure, were detected by the variation of proton nuclear relaxation time values and by X-ray, which showed an increase in the clay interlamellar space due to the intercalation of the polymer in the clay between lamellae. (author)

  3. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  4. ISABELLE insertion quadrupoles

    International Nuclear Information System (INIS)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented

  5. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  6. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  7. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  8. Insertion and crossing region design

    International Nuclear Information System (INIS)

    Wienands, U.; Beloshitsky, P.

    2001-01-01

    This article is the summary of the 5-afternoon tutorial on insertions for circular machines. Roughly half the course (Part 1) was spent discussing interaction regions, We start by recapitulating basic beam optics including building blocks. This provides the tools to analyze the basic structure of interaction regions and explore the parameter space. This simple example is then successively refined and made more realistic. Examples of realized interaction regions for both hadron and electron machines are shown and their salient features and differences explained. A brief discussion of solenoid-decoupling brings Part 1 to a close. In Part 2 we discussed various utility sections. Dispersion suppressors are presented in detail discussing the principles as well as the practical implementation of flexible suppressors using LEP as an example. Injection schemes, both single-turn and multi-turn stacking, are presented in depth. The matching of wiggler and undulator insertions and a discussion of the impact of these devices on beam parameters closes out Part 2

  9. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  10. Low field-low cost: Can low-field magnetic resonance systems replace high-field magnetic resonance systems in the diagnostic assessment of multiple sclerosis patients?

    International Nuclear Information System (INIS)

    Ertl-Wagner, B.B.; Reith, W.; Sartor, K.

    2001-01-01

    As low-field MR imaging is becoming a widely used imaging technique, we aimed at a prospective assessment of differences in imaging quality between low- and high-field MR imaging in multiple sclerosis patients possibly interfering with diagnostic or therapeutic decision making. Twenty patients with clinically proven multiple sclerosis were examined with optimized imaging protocols in a 1.5- and a 0.23-T MR scanner within 48 h. Images were assessed independently by two neuroradiologists. No statistically significant interrater discrepancies were observed. A significantly lower number of white matter lesions could be identified in low-field MR imaging both on T1- and on T2-weighted images (T2: high field 700, low field 481; T1: high field 253, low field 177). A total of 114 enhancing lesions were discerned in the high-field MR imaging as opposed to 45 enhancing lesions in low-field MR imaging. Blood-brain barrier disruption was identified in 11 of 20 patients in the high-field MR imaging, but only in 4 of 20 patients in low-field MR imaging. Since a significantly lower lesion load is identified in low-field MR imaging than in high-field MR imaging, and blood-brain barrier disruption is frequently missed, caution must be exercised in interpreting a normal low-field MR imaging scan in a patient with clinical signs of multiple sclerosis and in interpreting a scan without enhancing lesions in a patient with known multiple sclerosis and clinical signs of exacerbation. (orig.)

  11. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  12. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  13. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  14. The technique of MRT aided abdominal drainage using an open low field magnet. Feasibility and first results

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.; Schimmelpenning, H.; Weiss, H.D.

    1996-01-01

    To test the practicality of MRT-aided drainage using an open low field magnet and to report on the early clinical results. So far seven patients have been treated (four subphrenic abscesses, two psoas abscesses and one pancreatic pseudocyst). The planning of the approach and catheter insertion were carried out under MRT control (Magnetom Open, 0.2 T). Subsequent treatment was controlled by CT and fluoroscopy. Initial puncture was carried out with a non-magnetic 18 gauge Chiba needle. The drainage catheter was introduced by Seldinger's technique in six cases and with a trocar in one patient. In all seven patients drainage could be started successfully. The design of the magnet and coils permitted adequate accessibility of the patient. There were no problems in visualising the puncture needle. Controlling the position of the catheter by MRT was, however, difficult. The first two steps in abscess drainage (planning the approach and inserting the catheter) can be carried out under MRT control. For further catheter control and observing the course of the disease we presently prefer CT or fluoroscopy. (orig.) [de

  15. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  16. Ultra-Low Field SQUID-NMR using LN2 Cooled Cu Polarizing Field coil

    Science.gov (United States)

    Demachi, K.; Kawagoe, S.; Ariyoshi, S.; Tanaka, S.

    2017-07-01

    We are developing an Ultra-Low Field (ULF) Magnetic Resonance Imaging (MRI) system using a High-Temperature Superconductor superconducting quantum interference device (HTS rf-SQUID) for food inspection. The advantages of the ULF-NMR (Nuclear Magnetic Resonance) / MRI as compared with a conventional high field MRI are that they are compact and of low cost. In this study, we developed a ULF SQUID-NMR system using a polarizing coil to measure fat of which relaxation time T1 is shorter. The handmade polarizing coil was cooled by liquid nitrogen to reduce the resistance and accordingly increase the allowable current. The measured decay time of the polarizing field was 40 ms. The measurement system consisted of the liquid nitrogen cooled polarizing coil, a SQUID, a Cu wound flux transformer, a measurement field coil for the field of 47 μT, and an AC pulse coil for a 90°pulse field. The NMR measurements were performed in a magnetically shielded room to reduce the environmental magnetic field. The size of the sample was ϕ35 mm × L80 mm. After applying a polarizing field and a 90°pulse, an NMR signal was detected by the SQUID through the flux transformer. As a result, the NMR spectra of fat samples were obtained at 2.0 kHz corresponding to the measurement field Bm of 47 μT. The T1 relaxation time of the mineral oil measured in Bm was 45 ms. These results suggested that the ULF-NMR/MRI system has potential for food inspection.

  17. Low field Monte-Carlo calculations in heterojunctions and quantum wells

    NARCIS (Netherlands)

    Hall, van P.J.; Rooij, de R.; Wolter, J.H.

    1990-01-01

    We present results of low-field Monte-Carlo calculations and compare them with experimental results. The negative absolute mobility of minority electrons in p-type quantum wells, as found in recent experiments, is described quite well.

  18. An analytical model of anisotropic low-field electron mobility in wurtzite indium nitride

    International Nuclear Information System (INIS)

    Wang, Shulong; Liu, Hongxia; Song, Xin; Guo, Yulong; Yang, Zhaonian

    2014-01-01

    This paper presents a theoretical analysis of anisotropic transport properties and develops an anisotropic low-field electron analytical mobility model for wurtzite indium nitride (InN). For the different effective masses in the Γ-A and Γ-M directions of the lowest valley, both the transient and steady state transport behaviors of wurtzite InN show different transport characteristics in the two directions. From the relationship between velocity and electric field, the difference is more obvious when the electric field is low in the two directions. To make an accurate description of the anisotropic transport properties under low field, for the first time, we present an analytical model of anisotropic low-field electron mobility in wurtzite InN. The effects of different ionized impurity scattering models on the low-field mobility calculated by Monte Carlo method (Conwell-Weisskopf and Brooks-Herring method) are also considered. (orig.)

  19. Field quality issues in iron-dominated dipoles at low fields

    International Nuclear Information System (INIS)

    Brown, B.C.

    1996-10-01

    In order to help assess the usable dynamic range of iron-dominated dipoles, field shape data at low field on several Fermi-lab accelerator dipole designs are presented. Emphasis is placed on the systematic and random values of the low field sextupole since it is the first ''allowed'' field error. The Main Injector dipoles provide four times smaller sextupole and more than 20 times less sextupole hysteresis than earlier designs for the Main Ring

  20. 2-D Reflectometer Modeling for Optimizing the ITER Low-field Side Reflectometer System

    International Nuclear Information System (INIS)

    Kramer, G.J.; Nazikian, R.; Valeo, E.J.; Budny, R.V.; Kessel, C.; Johnson, D.

    2005-01-01

    The response of a low-field side reflectometer system for ITER is simulated with a 2?D reflectometer code using a realistic plasma equilibrium. It is found that the reflected beam will often miss its launch point by as much as 40 cm and that a vertical array of receiving antennas is essential in order to observe a reflection on the low-field side of ITER

  1. Measurement and Quantification of Heterogeneity, Flow, and Mass Transfer in Porous Media Using NMR Low-Field Techiques

    Science.gov (United States)

    Paciok, E.; Olaru, A. M.; Haber, A.; van Landeghem, M.; Haber-Pohlmeier, S.; Sucre, O. E.; Perlo, J.; Casanova, F.; Blümich, B.; RWTH Aachen Mobile Low-Field NMR

    2011-12-01

    Nuclear magnetic resonance (NMR) is renowned for its unique potential to both reveal and correlate spectroscopic, relaxometric, spatial and dynamic properties in a large variety of organic and inorganic systems. NMR has no restrictions regarding sample opacity and is an entirely non-invasive method, which makes it the ideal tool for the investigation of porous media. However, for years NMR research of soils was limited by the use of high-field NMR devices, which necessitated elaborate NMR experiments and were not applicable to bulky samples or on-site field measurements. The evolution of low-field NMR devices during the past 20 years has brought forth portable, small-scale NMR systems with open and closed magnet arrangements specialized to specific NMR applications. In combination with recent advances in 2D-NMR Laplace methodology [1], low-field NMR has opened up the possibility to study real-life microporous systems ranging from granular media to natural soils and oil well boreholes. Thus, information becomes available, which before has not been accessible with high-field NMR. In this work, we present our recent progress in mobile low-field NMR probe design for field measurements of natural soils: a slim-line logging tool, which can be rammed into the soil of interest on-site. The performance of the device is demonstrated in measurements of moisture profiles of model soils [2] and field measurements of relaxometric properties and moisture profiles of natural soils [3]. Moreover, an improved concept of the slim-line logging tool is shown, with a higher excitation volume and a better signal-to-noise due to an improved coil design. Furthermore, we present our recent results in 2D exchange relaxometry and simulation. These include relaxation-relaxation experiments on natural soils with varying degree of moisture saturation, where we could draw a connection between the relaxometric properties of the soil to its pore size-related diffusivity and to its clay content

  2. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  3. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  4. Observation of large low-field magnetoresistance in spinel cobaltite: A new half-metal

    KAUST Repository

    Li, Peng

    2015-12-10

    Low-field magnetoresistance is an effective and energy-saving way to use half-metallic materials in magnetic reading heads and magnetic random access memory. Common spin-polarized materials with low field magnetoresistance effect are perovskite-type manganese, cobalt, and molybdenum oxides. In this study, we report a new type of spinel cobaltite materials, self-assembled nanocrystalline NiCo2O4, which shows large low field magnetoresistance as large as –19.1% at 0.5 T and –50% at 9 T (2 K). The large low field magnetoresistance is attributed to the fast magnetization rotation of the core nanocrystals. The surface spin-glass is responsible for the observed weak saturation of magnetoresistance under high fields. Our calculation demonstrates that the half-metallicity of NiCo2O4 comes from the hopping eg electrons within the tetrahedral Co-atoms and the octahedral Ni-atoms. The discovery of large low-field magnetoresistance in simple spinel oxide NiCo2O4, a non-perovskite oxide, leads to an extended family of low-field magnetoresistance materials. (© 2016 WILEY-VCH Verlag GmbH &Co. KGaA, Weinheim)

  5. Observation of large low-field magnetoresistance in spinel cobaltite: A new half-metal

    KAUST Repository

    Li, Peng; Xia, Chuan; Zheng, Dongxing; Wang, Ping; Jin, Chao; Bai, Haili

    2015-01-01

    Low-field magnetoresistance is an effective and energy-saving way to use half-metallic materials in magnetic reading heads and magnetic random access memory. Common spin-polarized materials with low field magnetoresistance effect are perovskite-type manganese, cobalt, and molybdenum oxides. In this study, we report a new type of spinel cobaltite materials, self-assembled nanocrystalline NiCo2O4, which shows large low field magnetoresistance as large as –19.1% at 0.5 T and –50% at 9 T (2 K). The large low field magnetoresistance is attributed to the fast magnetization rotation of the core nanocrystals. The surface spin-glass is responsible for the observed weak saturation of magnetoresistance under high fields. Our calculation demonstrates that the half-metallicity of NiCo2O4 comes from the hopping eg electrons within the tetrahedral Co-atoms and the octahedral Ni-atoms. The discovery of large low-field magnetoresistance in simple spinel oxide NiCo2O4, a non-perovskite oxide, leads to an extended family of low-field magnetoresistance materials. (© 2016 WILEY-VCH Verlag GmbH &Co. KGaA, Weinheim)

  6. Electron cyclotron current drive at ω approx. = ωc with X-mode launched from the low field side

    International Nuclear Information System (INIS)

    Leuterer, F.; Kubo, S.

    2000-02-01

    The electron cyclotron resonance layer in a tokamak, ω=ω c (r), is not accessible by the extraordinary wave from the low field side, because it is shielded by a cutoff layer. However, a X-mode launched with a nonzero toroidal angle propagates at the cutoff parallel to the magnetic field and has a circular polarization. Therefore it can already at the cutoff layer interact efficiency with electrons via the Doppler shifted resonance. The driven current can be substantially higher than that driven by the second harmonic X-mode. The applicability of this current drive scheme is limited to rather low values of ω p 2 /ω c 2 , but may be of interest for high magnetic field devices. (author)

  7. Anisotropy of susceptibility in rocks which are magnetically nonlinear even in low fields

    Science.gov (United States)

    Hrouda, František; Chadima, Martin; Ježek, Josef

    2018-06-01

    Theory of the low-field anisotropy of magnetic susceptibility (AMS) assumes a linear relationship between magnetization and magnetizing field, resulting in field-independent susceptibility. This is valid for diamagnetic and paramagnetic minerals by definition and also for pure magnetite, while in titanomagnetite, pyrrhotite and hematite the susceptibility may be clearly field-dependent even in low fields used in common AMS meter. Consequently, the use of the linear AMS theory is fully legitimate in the former minerals, but in principle incorrect in the latter ones. Automated measurement of susceptibility in 320 directions in variable low-fields ranging from 5 to 700 A m-1 was applied to more than 100 specimens of various pyrrhotite-bearing and titanomagnetite-bearing rocks. Data analysis showed that the anisotropic susceptibility remains well represented by an ellipsoid in the entire low-field span even though the ellipsoid increases its volume and eccentricity. The principal directions do not change their orientations with low-field in most specimens. Expressions for susceptibility as a function of field were found in the form of diagonal tensor whose elements are polynomials of low order. In a large proportion of samples, the susceptibility expressions can be further simplified to have one common skeleton polynomial.

  8. Low-field susceptibilities of rare-earth spin glass alloys

    International Nuclear Information System (INIS)

    Sarkissian, B.V.B.

    1978-01-01

    The low-field AC susceptibilities of the dilute rare-earth spin glass alloys Sc-Gd, Sc-Tb, Pr-Tb and Pr-Gd are reported and compared with low-field DC susceptibilities of the same samples. The similarities between their behaviour and that of Au-Fe spin glass alloys is also considered. When single-ion anisotropy is important, this can cause a dramatic broadening of the sharp peak. Broadening in the AC peak has also observed as the frequency of the deriving field is increased. These data can be qualitatively discussed in terms of a recent magnetic-cluster model for spin glasses. (author)

  9. Low-field MR arthrography of the shoulder joint: technique, indications, and clinical results

    International Nuclear Information System (INIS)

    Kreitner, K.-F.; Thelen, M.; Loew, R.; Runkel, M.; Zoellner, J.

    2003-01-01

    In the age of cost containment and urgent reductions in health care expenditures, new options have to be explored to satisfy both diagnostic requirements and economic limitations. The introduction of low-field MR systems for assessment of joint disorders seemed to be an option for lower costs. The purpose of this article is to summarize available experiences with low-field MR arthrography of the glenohumeral joint with respect to image quality and diagnostic accuracy in detecting labral and rotator cuff lesions. Up to now, there has been only a limited number of studies available dealing with low-field MR arthrography of the glenohumeral joint. They reveal that, despite a minor image quality in comparison with high-field imaging, low-field MR arthrography of the shoulder allows for sufficient evaluation of intra- and extra-articular structures in the detection of major abnormalities such as glenohumeral instability or rotator cuff disease. Furthermore, open-configured MR scanners enable kinematic studies: Besides the analysis of normal motion, pathological findings in patients with instabilities and impingement syndrome can be delineated. They further offer the possibility for performing MR imaging-guided arthrography of the shoulder. This was first described using an open C-arm scanner with a vertically oriented magnetic field so that MR arthrography may be performed in one setting. (orig.)

  10. Usefulness of low-field FlAIR sequence in MR imaging of intracranial tumors

    International Nuclear Information System (INIS)

    Sokolowska, D.; Sasiadek, M.; Zimny, A.

    2004-01-01

    Plain MR study is often insufficient for visualization of all important details of intracranial tumors, hence there are attempts to use supplementary MR techniques. One of them is FLAIR (fluid attenuated inversion recovery) sequence which previously was available only in high-field MR units, but recently has been introduced also in less expensive low-field units. FLAIR is already widely used in the diagnostics of ischemic and demyelinating lesions, while there are few papers concerning its application in intracranial tumors, none of them regarding low-field MR units.The aim of our study was detailed evaluation of low-field FLAIR in the diagnostics of intracranial tumors. The material consisted of 76 patients with intracranial tumors, who were examined with low-field open MR unit (0.23 Tesla). In all patients, standard T2-weighted and T1-weighted (before and after contrast enhancement) sequences, as well as FLAIR sequence, were performed. The following symptoms were compared in the aforementioned sequences: tumor-edema, edema-brain and tumor-brain borders, visualization of tumour structure, vessels in the tumor area and precise tumor localization. A superiority of FLAIR in assessment of all symptoms has been confirmed, at least in part of the patient group. It concerned particularly the evaluation of brain-edema and edema-brain borders which were better visible with FLAIR than with all other sequences in 29 and 30 patients, respectively. In the assessment of the remaining symptoms (tumor-brain border, tumor structure, visualization of vessels, tumor localization) FLAIR was superior to other sequences in smaller number of patients (13,11,11 and 12, respectively). Totally, in 48 out of 76 patients (63.2%) FLAIR allowed better assessment of at least one of the analyzed symptoms. Low-field MR FLAIR enriches diagnostic information in majority of patients with intracranial tumors, therefore it should be included routinely in the diagnostic algorithm in this group of

  11. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  12. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  13. Leaky Apps and Data Shots: Leakage and Insertion in NSA-surveillance

    NARCIS (Netherlands)

    van der Velden, L.

    2015-01-01

    The NSA disclosures have put the issue of surveillance at center stage, and with that, a range of technologies by which data are captured. This article aims to break up devices for data collection by discussing devices that leak data versus devices that are inserted into computers or networks in

  14. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    An ISABELLE workshop of the summer 1976 series, which was held at Brookhaven August 16--20, focused on the design and utilization of the experimental insertions. The goals of the workshop are outlined, and a few general remarks about the results are presented

  15. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  17. Underwater radiation measuring device

    International Nuclear Information System (INIS)

    Seki, Noriyuki; Suzuki, Yasuo

    1998-01-01

    The present invention provides a device for measuring, under water, radiation from spent fuels (long members to be detected) of nuclear power plants and reprocessing facilities. Namely, a detecting insertion tube (insertion tube) is disposed so as to be in parallel with axial direction of the long member to be detected stored underwater. A γ-ray detector is inserted to the inside of the insertion tube. A driving mechanism is disposed for moving the γ-ray detector in axial direction inside of the insertion tube. The driving mechanism preferably has a system that it moves the γ-ray detector by winding a detection signal cable around a driving drum. The driving mechanism is formed by inserting and securing a driving tube having screws formed on the side surface and inserting it into the insertion tube. It may have a system of moving the γ-ray detector together with the driving tube while engaging the teeth of a driving transfer mechanism with the screws of the driving tube. (I.S.)

  18. Evaluation of poly(vinylpyrrolidone) and collagen by Low Field Nuclear Magnetic Resonance Spectroscopy

    International Nuclear Information System (INIS)

    Costa, Paula de M.; Tavares, Maria I.B.

    2005-01-01

    Blends of natural and synthetic polymers represent a new class of materials with better mechanical properties and biocompatibility than those of the single components. Collagen and poly(vinylpyrrolidone) are well known for their important biological properties. The blending of collagen with poly(vinylpyrrolidone) makes it possible to obtain new materials in which strong interactions between the synthetic and biological components occur. Do to the excellent biocompatibility of these polymers, this blend has been much studied intending biomedical applications. And a one technique that can provide important information on molecular mobility, compatibility and even evaluate the interactions that can occur with these polymers is the Low Field Nuclear Magnetic Resonance Spectroscopy. Thus, the purpose of this work is to evaluate collagen and poly(vinylpyrrolidone) by Low Field Nuclear Magnetic Resonance Spectroscopy. From the values of relaxation times obtained, we can conclude that these materials have different interactions, and different mobility domains, confirming the heterogeneity and complexity of these materials. (author)

  19. Guar gum/borax hydrogel: Rheological, low field NMR and release characterizations

    Directory of Open Access Journals (Sweden)

    M. Grassi

    2013-09-01

    Full Text Available Guar gum (GG and Guar gum/borax (GGb hydrogels are studied by means of rheology, Low Field Nuclear Magnetic Resonance (LF NMR and model drug release tests. These three approaches are used to estimate the mesh size (ζ of the polymeric network. A comparison with similar Scleroglucan systems is carried out. In the case of GGb, the rheological and Low Field NMR estimations of ζ lead to comparable results, while the drug release approach seems to underestimate ζ. Such discrepancy is attributed to the viscous effect of some polymeric chains that, although bound to the network to one end, can freely fluctuate among meshes. The viscous drag exerted by these chains slows down drug diffusion through the polymeric network. A proof for this hypothesis is given by the case of Scleroglucan gel, where the viscous contribution is not so significant and a good agreement between the rheological and release test approaches was found.

  20. Low-field multi-step magnetization of GaV4S8 single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Kajinami, Y; Tabata, Y [Department of Materials Science and Engineering, Kyoto University, Kyoto 606-8501 (Japan); Ikeno, R; Motoyama, G; Kohara, T, E-mail: h.nakamura@ht8.ecs.kyoto-u.ac.j [Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297 (Japan)

    2009-01-01

    The magnetization process of single crystalline GaV4S8 including tetrahedral magnetic clusters was measured in the magnetically ordered state below T{sub C} {approx_equal} 13 K. Just below TC, steps were observed at very low fields of the order of 100 Oe, suggesting the competition of several intra- and inter-cluster interactions in a low energy range.

  1. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  2. Low-field MRI of the ankle joint-first experience in the pediatric age group

    International Nuclear Information System (INIS)

    Herber, S.; Kreitner, K.F.; Kalden, P.; Loew, R.; Thelen, M.; Berger, S.

    2000-01-01

    Purpose: To evaluate the feasibility and diagnostic confidence of MRI with an open low field System (Magnetom open trademark , Siemens, Germany) in children with predominantly traumatic disorders. Material and methods: Conventional X-rays and MRI examinations have been evaluated in 55 children. MRI was performed at an open 0.2 T MR-unit. The study protocol comprised coronal STIR-sequence, an angulated T 2 weighted TSE-sequence and T 1 weighted SE-sequence. Results: MRI showed ligamental ruptur in 33/50 (60%) cases. Injuries of the ATFL were most frequent (27/33); osseous ligamental tears occurred in approx. 50% of all cases. Fractures of the distal tibia and fibula were diagnosed in 28/55 children. 15/28 cases showed an involvement of the epiphysis. We found occult fractures in 11/28 children. Fractures, diagnosed by conventional X-rays, were excluded in 6 cases. Therapy changed in 35/55 patients on the basis of MRI-findings. Conclusion: Low-field MRI of the ankle joint in children and adolescents is able to show numerous pathological conditions. We recommend low-field MRI of the ankle in children with persistent or unclear pain of the ankle joint and inconspicuous conventional X-ray. (orig.) [de

  3. Comparison of Low Field Electron Transport in Zincblende and Wurtzite SiC Structures for High Gain Device Modeling

    Directory of Open Access Journals (Sweden)

    Hadi Arabshahi

    2011-01-01

    Full Text Available Temperature and doping dependencies of electron mobility in both wurtzite and zincblende SiC structures have been calculated using an iteravive technique. The following scattering mechanisims, i.e, impurity, polar optical phonon, acoustic phonon, piezoelectric and electron plasmon are inculded in the calculation. Ionized imurity scattering has been treated beyound the Born approximation using the phase-shift analysis. It is found that the electron mobility decreases monotonically as the temperature increases from 100 to 500 K. The low temperature value of electron mobilty increases significantly with increasing doping concentration. The iterative results are in fair agreement with other recent calculations obtained using the relaxation-time approximation and experimental methods.

  4. The first LHC insertion quadrupole

    CERN Multimedia

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  5. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  6. Vacuum guidelines for ISA insertions

    International Nuclear Information System (INIS)

    Edwards, D. Jr.

    1976-01-01

    Vacuum requirements place design restrictions on the ISA insertions. The vacuum tube diameter, given a distance L between pumps, is determined by the desorption of molecules from the wall under the impact of ions created by the beam, whereas the thickness of the tube must be sufficient to prevent collapse. In addition, the entire vacuum chamber must be able to be baked out at approximately 200 0 C

  7. Inserts for nuclear fuel elements

    International Nuclear Information System (INIS)

    Cragg, P.J.

    1982-01-01

    An insert for a nuclear fuel pin which comprises a strip. The strip carries notches, which enable a coding arrangement to be carried on the strip. The notches may be of differing sizes and the coding on the strip includes identification and identification checking data. Each notch on the strip may give rise to a signal pulse which is counted by a detector to avoid errors. (author)

  8. ATLAS insertable B-layer

    Czech Academy of Sciences Publication Activity Database

    Marčišovský, Michal

    2011-01-01

    Roč. 633, č. 1 (2011), "S224"-"S225" ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA MŠk LA08015; GA MŠk LA08032 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * pixel detector * insertable B-layer Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.207, year: 2011

  9. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb$_{3}$Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb$_{3}$Sn m...

  10. Characterisation of protein stability in rod-insert vaginal rings.

    Science.gov (United States)

    Pattani, Aditya; Lowry, Deborah; Curran, Rhonda M; McGrath, Stephanie; Kett, Vicky L; Andrews, Gavin P; Malcolm, R Karl

    2012-07-01

    A major goal in vaccine development is elimination of the 'cold chain', the transport and storage system for maintenance and distribution of the vaccine product. This is particularly pertinent to liquid formulation of vaccines. We have previously described the rod-insert vaginal ring (RiR) device, comprising an elastomeric body into which are inserted lyophilised, rod-shaped, solid drug dosage forms, and having potential for sustained mucosal delivery of biomacromolecules, such as HIV envelope protein-based vaccine candidates. Given the solid, lyophilised nature of these insert dosage forms, we hypothesised that antigen stability may be significantly increased compared with more conventional solubilised vaginal gel format. In this study, we prepared and tested vaginal ring devices fitted with lyophilised rod inserts containing the model antigen bovine serum albumin (BSA). Both the RiRs and the gels that were freeze-dried to prepare the inserts were evaluated for BSA stability using PAGE, turbidimetry, microbial load, MALDI-TOF and qualitative precipitate solubility measurements. When stored at 4 °C, but not when stored at 40 °C/75% RH, the RiR formulation offered protection against structural and conformational changes to BSA. The insert also retained matrix integrity and release characteristics. The results demonstrate that lypophilised gels can provide relative protection against degradation at lower temperatures compared to semi-solid gels. The major mechanism of degradation at 40 °C/75% RH was shown to be protein aggregation. Finally, in a preliminary study, we found that addition of trehalose to the formulation significantly reduces the rate of BSA degradation compared to the original formulation when stored at 40 °C/75% RH. Establishing the mechanism of degradation, and finding that degradation is decelerated in the presence of trehalose, will help inform further development of RiRs specifically and polymer based freeze-dried systems in general. Copyright

  11. Multilayer mirrors as power filters in insertion device beamlines

    International Nuclear Information System (INIS)

    Kortright, J.B.; DiGennaro, R.S.

    1988-08-01

    The power-filtering capabilities of multilayer band-pass x-ray mirrors relative to total reflection low-pass mirrors is presented. Results are based on calculations assuming proposed wiggler sources on the upcoming generation of low energy (1.5 GeV) and high energy (7.0 GeV) synchrotron radiation sources. Results show that multilayers out-perform total reflection mirrors in terms of reduction in reflected power by roughly an order of magnitude, with relatively small increases in total absorbed power and power density over total reflection mirrors, and with comparable reflected flux values. Various aspects of this potential application of multilayer x-ray optics are discussed. 13 refs., 3 figs., 1 tab

  12. High performance lithium insertion negative electrode materials for electrochemical devices

    Energy Technology Data Exchange (ETDEWEB)

    Channu, V.S. Reddy, E-mail: chinares02@gmail.com [SMC Corporation, College Station, TX 77845 (United States); Rambabu, B. [Solid State Ionics and Surface Sciences Lab, Department of Physics, Southern University and A& M College, Baton Rouge, LA 70813 (United States); Kumari, Kusum [Department of Physics, National Institute of Technology, Warangal (India); Kalluru, Rajmohan R. [The University of Southern Mississippi, College of Science and Technology, 730 E Beach Blvd, Long Beach, MS 39560 (United States); Holze, Rudolf [Institut für Chemie, AG Elektrochemie, Technische Universität Chemnitz, D-09107 Chemnitz (Germany)

    2016-11-30

    Highlights: • LiCrTiO{sub 4} nanostructures were synthesized for electrochemical applications by soft chemical synthesis followed by annealing. • The presence of Cr and Ti elements are confirmed from the EDS spectrum. • Oxalic acid assisted LiCrTiO{sub 4} electrode shows higher specific capacity (mAh/g). - Abstract: Spinel LiCrTiO{sub 4} oxides to be used as electrode materials for a lithium ion battery and an asymmetric supercapacitor were synthesized using a soft-chemical method with and without chelating agents followed by calcination at 700 °C for 10 h. Structural and morphological properties were studied with powder X-ray diffraction, scanning electron and transmission electron microscopy. Particles of 50–10 nm in size are observed in the microscopic images. The presence of Cr and Ti is confirmed from the EDS spectrum. Electrochemical properties of LiCrTiO{sub 4} electrode were examined in a lithium ion battery. The electrode prepared with oxalic acid-assisted LiCrTiO{sub 4} shows higher specific capacity.This LiCrTiO{sub 4} is also used as anode material for an asymmetric hybrid supercapacitor. The cell exhibits a specific capacity of 65 mAh/g at 1 mA/cm{sup 2}. The specific capacity decreases with increasing current densities.

  13. A three-dimensional magnetostatics computer code for insertion devices

    International Nuclear Information System (INIS)

    Chubar, O.; Elleaume, P.; Chavanne, J.

    1998-01-01

    RADIA is a three-dimensional magnetostatics computer code optimized for the design of undulators and wigglers. It solves boundary magnetostatics problems with magnetized and current-carrying volumes using the boundary integral approach. The magnetized volumes can be arbitrary polyhedrons with non-linear (iron) or linear anisotropic (permanent magnet) characteristics. The current-carrying elements can be straight or curved blocks with rectangular cross sections. Boundary conditions are simulated by the technique of mirroring. Analytical formulae used for the computation of the field produced by a magnetized volume of a polyhedron shape are detailed. The RADIA code is written in object-oriented C++ and interfaced to Mathematica (Mathematica is a registered trademark of Wolfram Research, Inc.). The code outperforms currently available finite-element packages with respect to the CPU time of the solver and accuracy of the field integral estimations. An application of the code to the case of a wedge-pole undulator is presented

  14. Ultra-low field nuclear magnetic resonance and magnetic resonance imaging to discriminate and identify materials

    Science.gov (United States)

    Matlashov, Andrei Nikolaevich; Urbaitis, Algis V.; Savukov, Igor Mykhaylovich; Espy, Michelle A.; Volegov, Petr Lvovich; Kraus, Jr., Robert Henry

    2013-03-05

    Method comprising obtaining an NMR measurement from a sample wherein an ultra-low field NMR system probes the sample and produces the NMR measurement and wherein a sampling temperature, prepolarizing field, and measurement field are known; detecting the NMR measurement by means of inductive coils; analyzing the NMR measurement to obtain at least one measurement feature wherein the measurement feature comprises T1, T2, T1.rho., or the frequency dependence thereof; and, searching for the at least one measurement feature within a database comprising NMR reference data for at least one material to determine if the sample comprises a material of interest.

  15. Low field NMR study of the latex derived from Brosimum parinarioides - Moraceae

    International Nuclear Information System (INIS)

    Miguez, Eduardo; Tavares, Maria Ines B.

    2009-01-01

    Brosimum parinarioides is a tree found in the Amazonia forest and its latex (Leite de Amapa) is often used like food and by the popular medicine in the treatment of tuberculosis and asthma. Being swallowed in nature, its necessary determinate the stability degree of this latex in the storage conditions in which is used in Amazonia. The analyses of T 2 data showed that the limit of stability is not longer than six month in the storage conditions used by the population of Amazonia. The Low field NMR proved to be an efficient method for this kind of study. (author)

  16. Regional insertion: an emergent approach

    International Nuclear Information System (INIS)

    Serra, M.T.F.; Nascimento Teixeira, P. do

    1989-01-01

    The Brazilian Electrical Sector incorporates new variables that expressing the extensive spectrum of environmental impacts in the take of decisions, referring to the viability of realizing a electrical undertaking, attends the several restrictions that are important by the sector and by the society in the environment area and promotes the adequate generation of liquid benefits, consequential of the electrical undertaking. Due to these factors, the Electrical Sector is improving the concept of regional insertion, with the sectorial expansion in long-dated and the created demand in the environmental and social area, focalizing the solution for these questions. (C.G.C.). 1 fig, 2 tabs

  17. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    The last ISABELLE workshop of the summer 1976 series, which was held at Brookhaven, August 16-20, focused on the design and utilization of the experimental insertions. The goals of the workshop, which were somewhat more general than might be suggested by the title, are: (1) review the ISABELLE proposal from the point of view of experimental use; (2) contribute useful information on the ''open questions'' in the ISABELLE design; (3) develop data for experimental equipment and operating cost estimates; and (4) project a first approximation to ISABELLE operating modes

  18. Large low-field magnetoresistance of Fe3O4 nanocrystal at room temperature

    International Nuclear Information System (INIS)

    Mi, Shu; Liu, Rui; Li, Yuanyuan; Xie, Yong; Chen, Ziyu

    2017-01-01

    Superparamagnetic magnetite (Fe 3 O 4 ) nanoparticles with an average size of 6.5 nm and good monodispersion were synthesized and investigated by X-ray diffraction, Raman spectrometer, transmission electron microscopy and vibrating sample magnetometer. Corresponding low-field magnetoresistance (LFMR) was tested by physical property measurement system. A quite high LFMR has been observed at room temperature. For examples, at a field of 3000 Oe, the LFMR is −3.5%, and when the field increases to 6000 Oe, the LFMR is up to −5.1%. The electron spin polarization was estimated at 25%. This result is superior to the previous reports showing the LFMR of no more than 2% at room temperature. The conduction mechanism is proposed to be the tunneling of conduction electrons between adjacent grains considering that the monodisperse nanocrystals may supply more grain boundaries increasing the tunneling probability, and consequently enhancing the overall magnetoresistance. - Highlights: • Superparamagnetic Fe3O4 nanoparticles with small size were synthesized. • A quite high LFMR has been observed at room temperature. • The more grain boundaries increase the tunneling probability and enlarge the MR. • The fast response of the sample increase the MR at a low field.

  19. Evaluation of sleep apnea syndrome (SAS) with low field MR fluoroscopy

    International Nuclear Information System (INIS)

    Fukatsu, Hiroshi; Ando, Yoko; Ishigaki, Takeo; Okada, Tamotsu.

    1995-01-01

    Eight cases of clinically diagnosed sleep apnea syndrome (SAS) and two normal volunteers were studied with low field MR fluoroscopy in order to monitor the waking and sleeping status of the upper airway. MR fluoroscopy revealed that only the sleeping patients showed occlusions of the upper airway. This technique provided us with useful information about the level, frequency and duration of occlusion in each case. Four of the eight patients demonstrated simple retropalatal occlusion, whereas the other four demonstrated mixed retropalatal and retropalato-retroglossal occlusion. Thus long-time monitoring, which is only possible with MR fluoroscopy, is needed to appreciate the complex nature of the disease. In addition, the comfortable surroundings and low noise level provided by the low field enabled physiological study to be performed without any tranquilizers in most of the patients, which is again only possible with MR fluoroscopy. MR fluoroscopy may become a tool of great clinical value, providing much important information for disease evaluation and treatment selection. (author)

  20. Assessing the wettability of unconsolidated porous media using low-field nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Manalo, Florence Pabalan

    2002-01-01

    Methods such as the molarity of ethanol droplet (MED) test and water drop penetration test (WDPT) are commonly used to measure soil wettability because these tests are quick and easy to perform. However, they are not without limitations. This thesis proposes using a low-field NMR relaxometer as an alternative method of assessing soil wettability. This instrument is able to discriminate surface bound fluid from bulk fluid Fluid bound to the surface relaxes quickly and produces signal amplitude peaks at low transverse relaxation time (T 2 ) values. Bulk fluid , on the other hand, relaxes much more slowly and signal amplitude peaks consequently appear at higher T 2 values. An extensive experimental program was designed to test the above hypothesis. Hundreds of NMR measurements were performed on clays, humic acids, fulvic acids, clean sands, sands coated with organic matter, wettable soils and water-repellent soils exposed to distilled water and kerosene. The results confirm the hypothesis and show clearly that NMR does detect preferentially water-wet and water-repellent samples. The differences in the solid-fluid interactions between water and unconsolidated porous media with varying wetting preferences also allow for the use of low-field NMR to detect wettability alteration and to monitor fluid uptake in unconsolidated porous media. The advantages of using this tool include obtaining reproducible results quickly, using only small amounts of sample for analysis, and calculating the mass of water without performing a mass balance calculation. (author)

  1. The kinetics of porous insertion electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Atlung, S; West, K [British Columbia Univ., Vancouver (Canada)

    1989-05-01

    The principles of porous electrodes are discussed as well as the discharge of the insertion compound, the working potential, transport in the electrolyte, the time dependence of the electrolyte concentration, and modeling of the porous electrode. The simulation of a TiS2 porous electrode and the composite insertion electrode are considered as well. The influence of electrode thickness and porosity in a typical porous TiS2 electrode is revealed. It is shown that the use of insertion compounds as battery electrodes is limited by the requirement that the inserted ion must be distributed in the interior of the insertion compound particle. 15 refs.

  2. Acute changes associated with electrode insertion measured with optical coherence microscopy

    Science.gov (United States)

    Hammer, Daniel X.; Lozzi, Andrea; Boretsky, Adam; Agrawal, Anant; Welle, Cristin G.

    2016-03-01

    Despite advances in functional neural imaging, penetrating microelectrodes provide the most direct interface for the extraction of neural signals from the nervous system and are a critical component of many high degree-of-freedom braincomputer interface devices. Electrode insertion is a traumatic event that elicits a complex neuroinflammatory response. In this investigation we applied optical coherence microscopy (OCM), particularly optical coherence angiography (OCA), to characterize the immediate tissue response during microelectrode insertion. Microelectrodes of varying dimension and footprint (one-, two-, and four-shank) were inserted into mouse motor cortex beneath a window after craniotomy surgery. The microelectrodes were inserted in 3-4 steps at 15-20°, with approximately 250 μm linear insertion distance for each step. Before insertion and between each step, OCM datasets were collected, including for quantitative capillary velocimetry. A cohort of control animals without microelectrode insertion was also imaged over a similar time period (2-3 hours). Mechanical tissue deformation was observed in all the experimental animals. The quantitative angiography results varied across animals, and were not correlated with device dimensions. In some cases, localized flow drop-out was observed in a small region surrounding the electrode, while in other instances a global disruption in flow occurred, perhaps as a result of large vessel compression caused by mechanical pressure. OCM is a tool that can be used in various neurophotonics applications, including quantification of the neuroinflammatory response to penetrating electrode insertion.

  3. Low-field NMR logging sensor for measuring hydraulic parameters of model soils

    Science.gov (United States)

    Sucre, Oscar; Pohlmeier, Andreas; Minière, Adrien; Blümich, Bernhard

    2011-08-01

    SummaryKnowing the exact hydraulic parameters of soils is very important for improving water management in agriculture and for the refinement of climate models. Up to now, however, the investigation of such parameters has required applying two techniques simultaneously which is time-consuming and invasive. Thus, the objective of this current study is to present only one technique, i.e., a new non-invasive method to measure hydraulic parameters of model soils by using low-field nuclear magnetic resonance (NMR). Hereby, two model clay or sandy soils were respectively filled in a 2 m-long acetate column having an integrated PVC tube. After the soils were completely saturated with water, a low-field NMR sensor was moved up and down in the PVC tube to quantitatively measure along the whole column the initial water content of each soil sample. Thereafter, both columns were allowed to drain. Meanwhile, the NMR sensor was set at a certain depth to measure the water content of that soil slice. Once the hydraulic equilibrium was reached in each of the two columns, a final moisture profile was taken along the whole column. Three curves were subsequently generated accordingly: (1) the initial moisture profile, (2) the evolution curve of the moisture depletion at that particular depth, and (3) the final moisture profile. All three curves were then inverse analyzed using a MATLAB code over numerical data produced with the van Genuchten-Mualem model. Hereby, a set of values ( α, n, θr and θs) was found for the hydraulic parameters for the soils under research. Additionally, the complete decaying NMR signal could be analyzed through Inverse Laplace Transformation and averaged on the 1/ T2 space. Through measurement of the decay in pure water, the effect on the relaxation caused by the sample could be estimated from the obtained spectra. The migration of the sample-related average with decreasing saturation speaks for a enhancement of the surface relaxation as the soil dries, in

  4. Development of contaminant detection system based on ultra-low field SQUID-NMR/MRI

    International Nuclear Information System (INIS)

    Tsunaki, S; Yamamoto, M; Hatta, J; Hatsukade, Y; Tanaka, S

    2014-01-01

    We have developed an ultra-low field (ULF) NMR/MRI system using an HTS-rf-SQUID and evaluated performance of the system as a contaminant detection system for foods and drinks. In this work, we measured 1D MRIs from water samples with or without various contaminants, such as aluminum and glass balls using the system. In the 1D MRIs, changes of the MRI spectra were detected, corresponding to positions of the contaminants. We measured 2D MRIs from food samples with and without a hole. In the 2D MRIs, the hole position in the sample was well visualized. These results show that the feasibility of the system to detect and localize contaminants in foods and drinks.

  5. Ultra-low field NMR for detection and characterization of 235 UF6

    Energy Technology Data Exchange (ETDEWEB)

    Espy, Michelle A [Los Alamos National Laboratory; Magnelind, Per E [Los Alamos National Laboratory; Matlashov, Andrei N [Los Alamos National Laboratory; Urbaitis, Algis V [Los Alamos National Laboratory; Volegov, Petr L [Los Alamos National Laboratory

    2009-01-01

    We have demonstrated the first ultra-low field (ULF) nuclear magnetic resonance measurements of uranium hexafluoride (UF{sub 6}), both depleted and 70% enriched, which is used in the uranium enrichment process. A sensitive non-invasive detection system would have an important role in non-proliferation surveillance. A two-frequency technique was employed to remove the transients induced by rapidly switching off the 50 mT pre-polarization field. A mean transverse relaxation time T{sub 2} of 24 ms was estimated for the un-enriched UF{sub 6} sample measured at a mean temperature of 80 C. Nuclear magnetic resonance at ULF has several advantages including the ability to measure through metal, such as pipes, and simple magnetic field generation hardware. We present here recent data and discuss the potential for non-proliferation monitoring of enrichment and flow velocity.

  6. Low-Field Mobility and Galvanomagnetic Properties of Holes in Germanium with Phonon Scattering

    DEFF Research Database (Denmark)

    Lawætz, Peter

    1968-01-01

    acoustic scattering, no overall consistency is found between available galvanomagnetic data and deformation potentials derived directly from experiments on strained Ge. The discrepancies may be ascribed to ionized-impurity scattering, but at higher temperatures where optical phonon scattering is operative......A theoretical calculation of the low-field galvanomagnetic properties of holes in Ge has been carried out incorporating all relevant details of the band structure. The scattering is limited to acoustic and optical phonons and is described by the deformation potentials a, b, d, and d0. For pure......, the deviations are still appreciable. We are led to conclude that the deformation-potential theory of phonon scattering needs reconsideration, and a nontrivial correction is pointed out....

  7. Direct imaging of neural currents using ultra-low field magnetic resonance techniques

    Science.gov (United States)

    Volegov, Petr L [Los Alamos, NM; Matlashov, Andrei N [Los Alamos, NM; Mosher, John C [Los Alamos, NM; Espy, Michelle A [Los Alamos, NM; Kraus, Jr., Robert H.

    2009-08-11

    Using resonant interactions to directly and tomographically image neural activity in the human brain using magnetic resonance imaging (MRI) techniques at ultra-low field (ULF), the present inventors have established an approach that is sensitive to magnetic field distributions local to the spin population in cortex at the Larmor frequency of the measurement field. Because the Larmor frequency can be readily manipulated (through varying B.sub.m), one can also envision using ULF-DNI to image the frequency distribution of the local fields in cortex. Such information, taken together with simultaneous acquisition of MEG and ULF-NMR signals, enables non-invasive exploration of the correlation between local fields induced by neural activity in cortex and more `distant` measures of brain activity such as MEG and EEG.

  8. 2D dose distribution images of a hybrid low field MRI-γ detector

    Energy Technology Data Exchange (ETDEWEB)

    Abril, A., E-mail: ajabrilf@unal.edu.co; Agulles-Pedrós, L., E-mail: lagullesp@unal.edu.co [Medical Physics Group, Physics department, Universidad Nacional de Colombia, Bogotá (Colombia)

    2016-07-07

    The proposed hybrid system is a combination of a low field MRI and dosimetric gel as a γ detector. The readout system is based on the polymerization process induced by the gel radiation. A gel dose map is obtained which represents the functional part of hybrid image alongside with the anatomical MRI one. Both images should be taken while the patient with a radiopharmaceutical is located inside the MRI system with a gel detector matrix. A relevant aspect of this proposal is that the dosimetric gel has never been used to acquire medical images. The results presented show the interaction of the {sup 99m}Tc source with the dosimetric gel simulated in Geant4. The purpose was to obtain the planar γ 2D-image. The different source configurations are studied to explore the ability of the gel as radiation detector through the following parameters; resolution, shape definition and radio-pharmaceutical concentration.

  9. Relaxation rates of low-field gas-phase ^129Xe storage cells

    Science.gov (United States)

    Limes, Mark; Saam, Brian

    2010-10-01

    A study of longitudinal nuclear relaxation rates T1 of ^129Xe and Xe-N2 mixtures in a magnetic field of 3.8 mT is presented. In this regime, intrinsic spin relaxation is dominated by the intramolecular spin-rotation interaction due to persistent xenon dimers, a mechanism that can be quelled by introducing large amounts of N2 into the storage cell. Extrinsic spin relaxation is dominated by the wall-relaxation rate, which is the primary quantity of interest for the various low-field storage cells and coatings that we have tested. Previous group work has shown that extremely long gas-phase relaxation times T1 can be obtained, but only at large magnetic fields and low xenon densities. The current work is motivated by the practical benefits of retaining hyperpolarized ^129Xe for extended periods of time in a small magnetic field.

  10. Ultra low field MR imaging of cervical spine involvement in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Fagerlund, M.; Bjoernebrink, J.; Ekelund, L.; Toolanen, G. (Umeaa Univ. Hospital (Sweden). Depts. of Diagnostic Radiology and Orthopedic Surgery)

    1992-03-01

    In a study of 30 patients with longstanding rheumatoid arthritis the diagnostic usefulness of ultra low field MR equipment was analyzed in assessing lesions of the craniocervical junction. It was found that at 0.04 T all the examinations were diagnostic and that in combination with plain radiography the diagnostic information obtained was valuable in further planning of the treatment strategies. The neurologic findings were related to the degree and severity of atlantoaxial luxation, either horizontal or vertical, and to the periodontoid pannus formation. The correlation between the degree of cord compression shown with MR imaging and the clinical symptoms, especially long tract symptoms, was poor. The only correlating factor was the duration of the disease. (orig.).

  11. Thales: an instrument to measure the low field magnetophoretic mobility of microscopic objects

    International Nuclear Information System (INIS)

    Hackett, S L; St Pierre, T G

    2005-01-01

    An instrument, Thales, was designed and constructed to measure the induce motion of magnetic microspheres in a low magnetic field strength environment. Results show that Thales can be used to precisely measure the speed of microspheres (± 0.08 μm.s -1 ). We evaluated the motion of magnetic microspheres induced by an inhomogeneous magnetic field, and developed models for the microsphere magnetophoretic mobility, a parameter determining the speed attained by the microsphere in a given static low strength magnetic field environment. The data suggested that the magnetic material was located at the surfaces of the microspheres rather than being distributed evenly through the microspheres. With suitable calibration microspheres, Thales will be capable of directly measuring the low field magnetophoretic mobility of microscopic objects

  12. Detection of Virgin Olive Oil Adulteration Using Low Field Unilateral NMR

    Directory of Open Access Journals (Sweden)

    Zheng Xu

    2014-01-01

    Full Text Available The detection of adulteration in edible oils is a concern in the food industry, especially for the higher priced virgin olive oils. This article presents a low field unilateral nuclear magnetic resonance (NMR method for the detection of the adulteration of virgin olive oil that can be performed through sealed bottles providing a non-destructive screening technique. Adulterations of an extra virgin olive oil with different percentages of sunflower oil and red palm oil were measured with a commercial unilateral instrument, the profile NMR-Mouse. The NMR signal was processed using a 2-dimensional Inverse Laplace transformation to analyze the transverse relaxation and self-diffusion behaviors of different oils. The obtained results demonstrated the feasibility of detecting adulterations of olive oil with percentages of at least 10% of sunflower and red palm oils.

  13. Low-field vortex pinning model for undoped sintered MgB2 powders

    International Nuclear Information System (INIS)

    Agassi, Y D

    2011-01-01

    Sintered MgB 2 powders constitute a porous ensemble of irregularly shaped agglomerates of tightly packed grains. The low-field critical current density in such powders was experimentally observed to scale with the inverse of the average agglomerate size. Motivated by this observation we consider a flux pinning model which accounts for the MgB 2 powder porosity by focusing on a single finite-size agglomerate size. According to the model the observed critical current density dependence on the agglomerate size reflects the outward pull exerted on a vortex that is pinned in proximity to the agglomerate edges. The calculated critical current density replicates the observed scaling within agglomerate-size bounds. Implications of the model are discussed.

  14. Precise measurements and shimming of magnetic field gradients in the low field regime

    Energy Technology Data Exchange (ETDEWEB)

    Allmendinger, Fabian; Schmidt, Ulrich [Physikalisches Institut, Universitaet Heidelberg (Germany); Grasdijk, Olivier; Jungmann, Klaus; Willmann, Lorenz [University of Groningen (Netherlands); Heil, Werner; Karpuk, Sergei; Repetto, Maricel; Sobolev, Yuri; Zimmer, Stefan [Institut fuer Physik, Universitaet Mainz (Germany); Krause, Hans-Joachim; Offenhaeuser, Andreas [Peter Gruenberg Institut, Forschungszentrum Juelich (Germany); Collaboration: MIXed-Collaboration

    2016-07-01

    For many experiments at the precision frontier of fundamental physics, the accurate measurement and knowledge of magnetic field gradients in particular in the low field regime (<μT) is a necessity: On the one hand, in the search for an Electric Dipole Moment (EDM) of free neutrons or atoms, field gradients contribute to geometric-phase-induced false EDM signals for particles in traps. On the other hand, clock comparison experiments like the {sup 3}He/{sup 129}Xe spin clock experiment suffer from gradients, since the coherent T{sub 2}*-time of free spin precession, and thus the measurement sensitivity, scales ∝ ∇ vector B{sup -2}. Here we report on a new and very effective method, to shim and to measure tiny magnetic field gradients in the range of pT/cm by using effective T{sub 2}*-measurement sequences in varying the currents of trim coils of known geometry.

  15. Diagnostic value of low-field MRI for acute poisoning brain injury

    International Nuclear Information System (INIS)

    Dang Lianrong; He Qinyi

    2012-01-01

    Objective: To investigate the value of low-field MIR in diagnosis of acute CO poisoning brain injury. Methods: The brain MIR and clinical data of 110 patients with acute CO poisoning brain injury confirmed by clinical examination were retrospectively analyzed. Results: Long T1 and T2 signal intensity was showed on MRI in cerebral hemispheres and globus pallidus symmetrically. There were three basic types of MIR manifestations, white matter of brain type, globus pallidus type and brain mixed type. Conclusions: MRI could be used for confirming the degree and range of acute CO poisoning brain injury. It has important clinical value in the diagnosis, staging and prognosis of patients with acute CO poisoning brain injury. (authors)

  16. 2D dose distribution images of a hybrid low field MRI-γ detector

    International Nuclear Information System (INIS)

    Abril, A.; Agulles-Pedrós, L.

    2016-01-01

    The proposed hybrid system is a combination of a low field MRI and dosimetric gel as a γ detector. The readout system is based on the polymerization process induced by the gel radiation. A gel dose map is obtained which represents the functional part of hybrid image alongside with the anatomical MRI one. Both images should be taken while the patient with a radiopharmaceutical is located inside the MRI system with a gel detector matrix. A relevant aspect of this proposal is that the dosimetric gel has never been used to acquire medical images. The results presented show the interaction of the "9"9"mTc source with the dosimetric gel simulated in Geant4. The purpose was to obtain the planar γ 2D-image. The different source configurations are studied to explore the ability of the gel as radiation detector through the following parameters; resolution, shape definition and radio-pharmaceutical concentration.

  17. 2D dose distribution images of a hybrid low field MRI-γ detector

    Science.gov (United States)

    Abril, A.; Agulles-Pedrós, L.

    2016-07-01

    The proposed hybrid system is a combination of a low field MRI and dosimetric gel as a γ detector. The readout system is based on the polymerization process induced by the gel radiation. A gel dose map is obtained which represents the functional part of hybrid image alongside with the anatomical MRI one. Both images should be taken while the patient with a radiopharmaceutical is located inside the MRI system with a gel detector matrix. A relevant aspect of this proposal is that the dosimetric gel has never been used to acquire medical images. The results presented show the interaction of the 99mTc source with the dosimetric gel simulated in Geant4. The purpose was to obtain the planar γ 2D-image. The different source configurations are studied to explore the ability of the gel as radiation detector through the following parameters; resolution, shape definition and radio-pharmaceutical concentration.

  18. Study of relaxation times of nanocomposites of starch/montmorillonite employing low field NMR

    International Nuclear Information System (INIS)

    Brito, Luciana M.; Tavares, Maria Ines B.

    2011-01-01

    Due to its various applications and features, especially in therapies for controlled release of pharmaceuticals, polymers are among the most widely used excipients in pharmaceutical technology. One of the most promising nanocomposites is formed from organic polymer and inorganic clay minerals. Nanocomposites of starch/montmorillonite were prepared employing solution intercalation and characterized by proton spin-lattice relaxation time, through NMR relaxometry. The characterization of nanocomposites was done by X-ray diffraction and by nuclear magnetic resonance. The results showed that nanostructured films were obtained by intercalation from solution. Furthermore, the use of low field NMR, T1H, provided more precise information about the movement of materials, being complementary to the results obtained by X-ray diffraction. (author)

  19. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zevenhoven, Koos C. J.; Ilmoniemi, Risto J.; Dong, Hui; Clarke, John

    2015-01-01

    Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents

  20. Low-field MRI can be more sensitive than high-field MRI

    Science.gov (United States)

    Coffey, Aaron M.; Truong, Milton L.; Chekmenev, Eduard Y.

    2013-12-01

    MRI signal-to-noise ratio (SNR) is the key factor for image quality. Conventionally, SNR is proportional to nuclear spin polarization, which scales linearly with magnetic field strength. Yet ever-stronger magnets present numerous technical and financial limitations. Low-field MRI can mitigate these constraints with equivalent SNR from non-equilibrium ‘hyperpolarization' schemes, which increase polarization by orders of magnitude independently of the magnetic field. Here, theory and experimental validation demonstrate that combination of field independent polarization (e.g. hyperpolarization) with frequency optimized MRI detection coils (i.e. multi-turn coils using the maximum allowed conductor length) results in low-field MRI sensitivity approaching and even rivaling that of high-field MRI. Four read-out frequencies were tested using samples with identical numbers of 1H and 13C spins. Experimental SNRs at 0.0475 T were ∼40% of those obtained at 4.7 T. Conservatively, theoretical SNRs at 0.0475 T 1.13-fold higher than those at 4.7 T were possible despite an ∼100-fold lower detection frequency, indicating feasibility of high-sensitivity MRI without technically challenging, expensive high-field magnets. The data at 4.7 T and 0.0475 T was obtained from different spectrometers with different RF probes. The SNR comparison between the two field strengths accounted for many differences in parameters such as system noise figures and variations in the probe detection coils including Q factors and coil diameters.

  1. One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

    Energy Technology Data Exchange (ETDEWEB)

    Agulles-Pedrós, L., E-mail: lagullesp@unal.edu.co; Abril, A., E-mail: ajabrilf@unal.edu.co [Medical Physics Group, Physics Department, Universidad Nacional de Colombia, Bogotá (Colombia)

    2016-07-07

    Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

  2. Low field MR imaging of sellar and parasellar lesions: Experience in a developing country hospital

    International Nuclear Information System (INIS)

    Ogbole, G.I.; Adeyinka, O.A.; Okolo, C.A.; Ogun, A.O.; Atalabi, O.M.

    2012-01-01

    Background: Magnetic resonance imaging (MRI), an advancement which followed computed tomography (CT) is expensive and inaccessible in most developing countries. However it is the procedure of choice in evaluating sellar and parasellar lesions. Its major advantages are its superior soft tissue contrast differentiation, its capacity for multiplanar imaging and nonexistence of ionising radiation. Its use is relatively new in Nigeria, a developing economy in Africa. Since its introduction in 2005, it has been utilised extensively for neuroimaging at the University College Hospital (UCH), Ibadan; a large hospital in south-western Nigeria. Objective: To review the role and pattern of low field MR Imaging in sellar and parasellar lesions presenting to a tertiary care centre in Nigeria. Methods: All 62 patients with clinically suspected sellar and parasellar masses, referred to the Department of Radiology, UCH Ibadan for MRI between December 2006 and January 2010 were retrospectively analysed. The examinations were performed using an open 0.2 T permanent magnet MR unit. T1W, T2W, T2/FLAIR, TOF and T1W post gadolinium DTPA sequences of the sellar region were obtained. Results: Of the 62 patients, there were 27 males and 35 females. The modal age group was 40–49 years with a mean age of 39.94 years (±16.65 years). Twenty-four cases (38.7%) had histological diagnosis, of which 20 (83.3%) were consistent with initial MRI diagnosis. Pituitary adenomas were the commonest (58.06%) lesions of the sellar and parasellar regions. Others include parasellar meningiomas, cranipharyngiomas, and giant aneurysms. Headache and visual impairment were the major presenting features and showed no significant correlation with tumour size. Conclusion: The use of low field MRI in the diagnostic evaluation of patients with suspected sellar or parasellar lesions in developing countries of low economic resource is commendable as it provides beneficial outcomes in management.

  3. Effects of CO2 injection and Kerogen Maturation on Low-Field Nuclear Magnetic Resonance Response

    Science.gov (United States)

    Prasad, M.; Livo, K.

    2017-12-01

    Low-field Nuclear Magnetic Resonance (NMR) is commonly used in petrophysical analysis of petroleum reservoir rocks. NMR experiments record the relaxation and polarization of in-situ hydrogen protons present in gaseous phases such as free-gas intervals and solution gas fluids, bulk fluid phases such as oil and aquifer intervals, and immovable fractions of kerogen and bitumen. Analysis of NMR relaxation spectra is performed to record how fluid composition, maturity, and viscosity change NMR experimental results. We present T1-T2 maps as thermal maturity of a water-saturated, sub-mature Woodford shale is increased at temperatures from 125 to 400 degrees Celsius. Experiments with applied fluid pressure in paraffinic mineral oil and DI water with varying fluid pH have been performed to mimic reservoir conditions in analysis of the relaxation of bulk fluid phases. We have recorded NMR spectra, T1-T2 maps, and fluid diffusion coefficients using a low-field (2 MHz) MagritekTM NMR. CO2 was injected at a pressure of 900 psi in an in house developed NMR pressure vessel made of torlon plastic. Observable 2D NMR shifts in immature kerogen formations as thermal maturity is increased show generation of lighter oils with increased maturity. CO2 injection leads to a decrease in bulk fluid relaxation time that is attributed to viscosity modification with gas presence. pH variation with increased CO2 presence were shown to not effect NMR spectra. From this, fluid properties have been shown to greatly affect NMR readings and must be taken into account for more accurate NMR reservoir characterization.

  4. MR equipment acquisition strategies: low-field or high-field scanners

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Kormano, M.

    1997-01-01

    Magnetic resonance (MR) field strength is one of the key aspects to consider when purchasing MR equipment. Other aspects include the gradient system, coil design, computer and pulse sequence availability, purchase cost, local reimbursement policies, and current opinion within the medical community. Our objective here is to evaluate the decision-influencing aspects of the MR market, with a focus on some specific areas such as high resolution studies, examination times, special techniques, instrumentation, open design magnets, costs and reimbursement policies, academic and industrial interests, contrast media, clinical efficacy, and finally, clinicians' preferences. Certainly the advantage of high-field is a higher signal-to-noise ratio and improved resolution. With a high-field unit, higher spatial resolution images and higher temporal resolution images can be obtained. Typical imaging times needed to produce clinically diagnostic images are about 3 times longer at 0.1 T than at 1.0 or 1.5 T. High-field-related advanced techniques, such as functional imaging, spectroscopy and microscopy, may become clinically useful in the near future. As long as there is an unlimited demand for MR examinations, it appears financially profitable to run a high-field system, despite the associated higher costs. However, if demand for MR becomes saturated, low-field systems will cause less financial strain on the reimbursement organisation and service provider. Recent emphasis on cost containment, the development of interventional techniques, the increased use of MR for patients in intensive care and operating suites, the deployment of magnets in office suites, and the development of new magnet configurations, all favour the supplementary use of low-field systems. Hence, MR units of all field strengths have a role in radiology. (orig.)

  5. Functional magnetic resonance imaging in a low-field intraoperative scanner.

    Science.gov (United States)

    Schulder, Michael; Azmi, Hooman; Biswal, Bharat

    2003-01-01

    Functional magnetic resonance imaging (fMRI) has been used for preoperative planning and intraoperative surgical navigation. However, most experience to date has been with preoperative images acquired on high-field echoplanar MRI units. We explored the feasibility of acquiring fMRI of the motor cortex with a dedicated low-field intraoperative MRI (iMRI). Five healthy volunteers were scanned with the 0.12-tesla PoleStar N-10 iMRI (Odin Medical Technologies, Israel). A finger-tapping motor paradigm was performed with sequential scans, acquired alternately at rest and during activity. In addition, scans were obtained during breath holding alternating with normal breathing. The same paradigms were repeated using a 3-tesla MRI (Siemens Corp., Allandale, N.J., USA). Statistical analysis was performed offline using cross-correlation and cluster techniques. Data were resampled using the 'jackknife' process. The location, number of activated voxels and degrees of statistical significance between the two scanners were compared. With both the 0.12- and 3-tesla imagers, motor cortex activation was seen in all subjects to a significance of p < 0.02 or greater. No clustered pixels were seen outside the sensorimotor cortex. The resampled correlation coefficients were normally distributed, with a mean of 0.56 for both the 0.12- and 3-tesla scanners (standard deviations 0.11 and 0.08, respectively). The breath holding paradigm confirmed that the expected diffuse activation was seen on 0.12- and 3-tesla scans. Accurate fMRI with a low-field iMRI is feasible. Such data could be acquired immediately before or even during surgery. This would increase the utility of iMRI and allow for updated intraoperative functional imaging, free of the limitations of brain shift. Copyright 2003 S. Karger AG, Basel

  6. Low-field-strength magnetic resonance imaging in the canine brain

    International Nuclear Information System (INIS)

    Esteve Ratsch, B.

    2000-06-01

    Magnetic resonance imaging (MRI; 0,23 T) of the canine brain was performed. Each scan plane was compared with corresponding anatomic sections. The best imaging planes to visualize various anatomic structures were determined. Low-field-strength MRI allowed the good definition of all relevant anatomic structures of the brain of 55 dogs with the exception of most cranial nerves. White matter could be best differentiated using proton-weighted images. On T1-weighted images the contrast of white matter was markedly limited in the living dogs in contrast to the examined canine specimens. The relative size of the lateral ventricle was defined as the ratio of the size of the lateral ventricle and the size of the half brain. The relative size of the lateral ventricle of Yorkshire Terrier dogs (5,35 %) was significantly (p 0,05) in the relative size of the lateral ventricles of healthy Yorkshire Terrier dogs (5,35 %) and Yorkshire Terrier dogs with neurological symptoms (7,06 %). Asymmetric lateral ventricles were very common in the examined dogs independently from body size, skull shape and neurological status. Occasionally the septum telencephali was not developed completely. 11 of 12 intracranial neoplasm could be delineated using low-field-strength MRI. Anatomic site, number of intracerebral lesions, limitation, shape and growth pattern, secondary brain lesions and development of peritumoral edema were described for each intracranial neoplasm as well as its signal intensity on T1- and T2-weighted images and contrast enhancement pattern. MRI did not allow an accurate diagnosis of tumor type, nevertheless skull shape (brachycephalic/dolichocephalic), anatomic site and number of intracerebral lesions facilitated a presumable diagnosis of the tumor type. (author)

  7. Usefulness of intraoperative ultra low-field magnetic resonance imaging in glioma surgery.

    Science.gov (United States)

    Senft, Christian; Seifert, Volker; Hermann, Elvis; Franz, Kea; Gasser, Thomas

    2008-10-01

    The aim of this study was to demonstrate the usefulness of a mobile, intraoperative 0.15-T magnetic resonance imaging (MRI) scanner in glioma surgery. We analyzed our prospectively collected database of patients with glial tumors who underwent tumor resection with the use of an intraoperative ultra low-field MRI scanner (PoleStar N-20; Odin Medical Technologies, Yokneam, Israel/Medtronic, Louisville, CO). Sixty-three patients with World Health Organization Grade II to IV tumors were included in the study. All patients were subjected to postoperative 1.5-T imaging to confirm the extent of resection. Intraoperative image quality was sufficient for navigation and resection control in both high- and low-grade tumors. Primarily enhancing tumors were best detected on T1-weighted imaging, whereas fluid-attenuated inversion recovery sequences proved best for nonenhancing tumors. Intraoperative resection control led to further tumor resection in 12 (28.6%) of 42 patients with contrast-enhancing tumors and in 10 (47.6%) of 21 patients with noncontrast-enhancing tumors. In contrast-enhancing tumors, further resection led to an increased rate of complete tumor resection (71.2 versus 52.4%), and the surgical goal of gross total removal or subtotal resection was achieved in all cases (100.0%). In patients with noncontrast-enhancing tumors, the surgical goal was achieved in 19 (90.5%) of 21 cases, as intraoperative MRI findings were inconsistent with postoperative high-field imaging in 2 cases. The use of the PoleStar N-20 intraoperative ultra low-field MRI scanner helps to evaluate the extent of resection in glioma surgery. Further tumor resection after intraoperative scanning leads to an increased rate of complete tumor resection, especially in patients with contrast-enhancing tumors. However, in noncontrast- enhancing tumors, the intraoperative visualization of a complete resection seems less specific, when compared with postoperative 1.5-T MRI.

  8. Homogeneity characterization of ethylene-co-vinyl acetate copolymer (EVA) and hydrophobic silica nanocomposite by low field NMR

    International Nuclear Information System (INIS)

    Stael, Giovanni Chaves; Tavares, Maria I.B.

    2005-01-01

    This project proposes the characterization of a polymeric matrix composite material using nanometric scale hydrophobic silica as charge element, with the ethylene-vinyl acetate (EVA), by using the spin-lattice relaxation time measurement applying the low field NMR

  9. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  10. Effects of Rotational Motion in Robotic Needle Insertion

    Science.gov (United States)

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  11. Low-field microwave absorption and magnetoresistance in iron nanostructures grown by electrodeposition on n-type lightly doped silicon substrates

    Energy Technology Data Exchange (ETDEWEB)

    Felix, J.F. [Universidade Federal de Viçosa-UFV, Departamento de Física, 36570-900 Viçosa, MG (Brazil); Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil); Figueiredo, L.C. [Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil); Mendes, J.B.S. [Universidade Federal de Viçosa-UFV, Departamento de Física, 36570-900 Viçosa, MG (Brazil); Morais, P.C. [Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil); Huazhong University of Science and Technology, School of Automation, 430074 Wuhan (China); Araujo, C.I.L. de., E-mail: dearaujo@ufv.br [Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil)

    2015-12-01

    In this study we investigate magnetic properties, surface morphology and crystal structure in iron nanoclusters electrodeposited on lightly doped (100) n-type silicon substrates. Our goal is to investigate the spin injection and detection in the Fe/Si lateral structures. The samples obtained under electric percolation were characterized by magnetoresistive and magnetic resonance measurements with cycling the sweeping applied field in order to understand the spin dynamics in the as-produced samples. The observed hysteresis in the magnetic resonance spectra, plus the presence of a broad peak in the non-saturated regime confirming the low field microwave absorption (LFMA), were correlated to the peaks and slopes found in the magnetoresistance curves. The results suggest long range spin injection and detection in low resistive silicon and the magnetic resonance technique is herein introduced as a promising tool for analysis of electric contactless magnetoresistive samples. - Highlights: • Electrodeposition of Fe nanostructures on high resistive silicon substrates. • Spin polarized current among clusters through Si suggested by isotropic magnetoresistance. • Low field microwave absorption arising from the sample shape anisotropy. • Contactless magnetoresistive device characterization by resonance measurements.

  12. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  13. Thermonuclear device

    International Nuclear Information System (INIS)

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  14. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  15. Photonics Research and Technology Insertion

    Science.gov (United States)

    2015-06-05

    state devices are intended to replace the present low-pressure mercury lamp emitting at 254nm. Approach: The BU team is a leader in UV LED ...7 Development of UV LEDs Emitting at 250-260 nm for Water-Air Purification and Surface Sterilization Task Manager: Professors Enrico Bellotti...Theodore Moustakas and Roberto Paiella/Leah Ziph-Schatzberg Objective: The team set out to develop electrically pumped UV LEDs emitting at 250

  16. Insertion material for controlling reactivity

    International Nuclear Information System (INIS)

    Baba, Iwao.

    1994-01-01

    Moderators and a group of suspended materials having substantially the same density as the moderator are sealed in a hollow rod vertically inserted to a fuel assembly. Specifically, the group of suspended materials is adapted to have a density changing stepwise from density of the moderator at the exit temperature of the reactor core to that at the inlet temperature of the reactor core. Reactivity is selectively controlled for a portion of high power and a portion of high reactivity by utilizing the density of the moderator and the distribution of the density. That is, if the power distribution is flat, the density of the moderators changes at a constant rate over the vertical direction of the reactor core and the suspended materials stay at a portion of the same density, to form a uniform distribution. Further, upon reactor shutdown, since the liquid temperature of the moderators is lowered and the density is increased, all of beads are collected at the upper portion to remove water at the upper portion of the reactor core of low burnup degree thereby selectively controlling the reactivity at a portion of high power and a portion of high reactivity. (N.H.)

  17. Hall effect enhanced low-field sensitivity in a three-contact extraordinary magnetoresistance sensor

    KAUST Repository

    Sun, Jian

    2012-06-06

    An extraordinary magnetoresistance (EMR) device with a 3-contact geometry has been fabricated and characterized. A large enhancement of the output sensitivity at low magnetic fields compared to the conventional EMR device has been found, which can be attributed to an additional influence coming from the Hall effect. Output sensitivities of 0.19 mV/T at zero-field and 0.2 mV/T at 0.01 T have been measured in the device, which is equivalent to the ones of the conventional EMR sensors with a bias of ∼0.04 T. The exceptional performance of EMR sensors in the high field region is maintained in the 3-contact device.

  18. Archive-cup insert for liquid-metal sampling

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Filewicz, E.C.; Holmes, J.T.

    1975-01-01

    An insert for collecting liquid-metal samples within a vertical casing including an elongated housing with an upper and a lower overflow seal of annular shape is described. The lower seal includes a centrally located pedestal on which a sample cup is disposed. Liquid metal enters the annulus of the upper seal and overflows into the cup which fills and overflows into the lower seal. Liquid-metal overflow from the lower seal is discharged from the insert. On cooling, the liquid metal trapped within the seals solidifies to hermetically isolate the metal sample within the cup. The device is particularly applicable for use with sampling systems on liquid metal-cooled reactors. (U.S.)

  19. Monitoring microbial growth and activity using spectral induced polarization and low-field nuclear magnetic resonance

    Science.gov (United States)

    Zhang, Chi; Keating, Kristina; Revil, Andre

    2015-04-01

    Microbes and microbial activities in the Earth's subsurface play a significant role in shaping subsurface environments and are involved in environmental applications such as remediation of contaminants in groundwater and oil fields biodegradation. Stimulated microbial growth in such applications could cause wide variety of changes of physical/chemical properties in the subsurface. It is critical to monitor and determine the fate and transportation of microorganisms in the subsurface during such applications. Recent geophysical studies demonstrate the potential of two innovative techniques, spectral induced polarization (SIP) and low-field nuclear magnetic resonance (NMR), for monitoring microbial growth and activities in porous media. The SIP measures complex dielectric properties of porous media at low frequencies of exciting electric field, and NMR studies the porous structure of geologic media and characterizes fluids subsurface. In this laboratory study, we examined both SIP and NMR responses from bacterial growth suspension as well as suspension mixed with silica sands. We focus on the direct contribution of microbes to the SIP and NMR signals in the absence of biofilm formation or biomineralization. We used Zymomonas mobilis and Shewanella oneidensis (MR-1) for SIP and NMR measurements, respectively. The SIP measurements were collected over the frequency range of 0.1 - 1 kHz on Z. mobilis growth suspension and suspension saturated sands at different cell densities. SIP data show two distinct peaks in imaginary conductivity spectra, and both imaginary and real conductivities increased as microbial density increased. NMR data were collected using both CPMG pulse sequence and D-T2 mapping to determine the T2-distribution and diffusion properties on S. oneidensis suspension, pellets (live and dead), and suspension mixed with silica sands. NMR data show a decrease in the T2-distribution in S. oneidensis suspension saturated sands as microbial density increase. A

  20. Placement of a peripherally inserted central catheter into the azygous vein

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, Iain, E-mail: iain.franklin@health.qld.gov.au; Gilmore, Christopher [The Prince Charles Hospital, Brisbane, Queensland (Australia)

    2015-06-15

    Peripherally inserted central catheters (PICC) are used for a variety of infusion therapies. They are indicated in patients requiring long-term venous access. Incorrect positioning of the insertion of a PICC line is one of the known complications when inserting the device in clinical practice. Radiographers once performing imaging will commonly check if the tip of a PICC has entered the superior vena cava. This case study will report on a lesser known incorrect placement of a PICC line into the azygous vein and how this can be detected on radiographic imaging. This outcome for the patient can be detrimental as it has an increased risk of perforation, thrombus, and fistula formation.

  1. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    Science.gov (United States)

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  2. Analysis of knee movement with low-field MR equipment. A normal volunteer study

    International Nuclear Information System (INIS)

    Ando, Yoko; Fukatsu, Hiroshi; Ishigaki, Takeo; Aoki, Ikuo; Yamada, Takashi.

    1994-01-01

    This study was performed to make a normal standard by analyzing knee movement in detail. An open low-field unit was used for 23 healthy knee joints. With three-dimensional Fourier transformation (3DFT) gradient echo sequence, 50 sagittal slices of 4.5 mm in thickness were obtained at four flexion angles: 0, 30, 60, and 90 degrees (lateral position). Although the tension ratio of the anterior and posterior cruciate ligaments (ACL, PCL) increased during knee flexion, the change in the tension ratio was significantly different between the ACL and PCL. The femur-ACL angle and femur-PCL angle were parallel with the knee flexion angle, but the tibia-ACL angle and tibia-PCL angle changed complexly. The lateral and medial condyles rolled and slid during knee flexion, and the medial side moved more than the lateral side, consistent with rotation of the lower thigh. The difference in backward movement distance on the tibia between the two condyles was significantly larger in females than in males. This might explain the dominance of knee osteoarthritis in women. Although the lateral position is not completely physiological, we could show initial cinematic data of up to 90 degrees of knee flexion using open-type MRI, which is impossible with high- and middle-field machines. (author)

  3. Characterization of polyurethane/organophilic montmorillonite nanocomposites by low field NMR

    International Nuclear Information System (INIS)

    Silva, Marcos Anacleto da; Tavares, Maria I.B.; Nascimento, Suelen A.M.; Rodrigues, Elton J. da R

    2012-01-01

    Polyurethanes are important and versatile materials, mainly due to some of their properties, such as high resistance to abrasion and tearing, excellent absorption of mechanical shocks and good flexibility and elasticity. However, they have some drawbacks as well, such as low thermal stability and barrier properties. To overcome these disadvantages, various studies have been conducted involving organophilic polyurethane/montmorillonite nanocomposites. The investigation of the structure of polyurethane/clay nanocomposites has mainly been done by X-ray diffraction (XRD) and transmission electron microscopy (TEM). In this work, PU/clay nanocomposite films obtained by solution intercalation were studied. The nanocomposites were characterized by XRD and low-field nuclear magnetic resonance (LF-NMR). The LF-NMR measurements, with determination of the spin-lattice relaxation time of the hydrogen nucleus, supplied important information about the molecular dynamics of these nanocomposites. The X-ray diffraction measurements validated the results found by NMR. The thermal stability of the material was also determined by thermogravimetric analysis (TGA) under an inert atmosphere. A slight improvement in this stability was observed in the nanocomposite in comparison with polyurethane (author)

  4. Magnetization, Low Field Instability and Quench of RHQT Nb(3)Al Strands

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, R.; Wake, M.; Kikuchi, A.; Velev, V.; /Fermilab

    2009-01-01

    Since 2005, we made and tested three RHQT Nb{sub 3}Al strands, one with Nb matrix and two with Ta matrix, which are fully stabilized with Cu electroplating. We observed anomalously large magnetization curves extending beyond 1 to 1.5 Tesla with the F1 Nb matrix strand at 4.2 K, when we measured its magnetization with a balanced coil magnetometer. This problem was eliminated with the Ta matrix strands operating at 4.2 K. But with these strands a similar but smaller anomalous magnetization was observed at 1.9 K. We studied these phenomena with FEM. With the F1 Nb matrix strand, it is explained that at low external field, inter-filamentary coupling currents in the outer layers of sub-elements create a shielding effect. It reduces the inside field, keeps the inside Nb matrix superconductive, and stands against a higher outside field beyond the Hc of Nb. At an even higher external field, the superconductivity of the whole Nb matrix collapses and releases a large amount of energy, which may cause a big quench. Depending on the size of the energy in the strand or the cable, a magnet could quench, causing the low field instability. Some attempt to analyze the anomaly with FEM is presented.

  5. High-pressure low-field 1H NMR relaxometry in nanoporous materials.

    Science.gov (United States)

    Horch, Carsten; Schlayer, Stefan; Stallmach, Frank

    2014-03-01

    A low-field NMR sensor with NdFeB permanent magnets (B0=118 mT) and a pressure cell made of PEEK (4 cm outer diameter) were designed for (1)H relaxation time studies of adsorbed molecules at pressures of up to 300 bar. The system was used to investigate methane uptake of microporous metal-organic frameworks and nanoporous activated carbon. T2 relaxation time distribution of pure methane and of methane under co-adsorption of carbon dioxide show that the host-guest interaction lead to a relaxation time contrasts, which may be used to distinguish between the gas phase and the different adsorbed phases of methane. Adsorption isotherms, exchange of methane between adsorbent particles and the surrounding gas phase, successive displacement of methane from adsorption sites by co-adsorption of carbon dioxide and CO2/CH4 adsorption separation factors were determined from the observed NMR relaxation time distributions. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Low field critical currents and ac losses of thin film niobium--tin superconductors

    International Nuclear Information System (INIS)

    Howard, R.E.

    1977-01-01

    The results of a study of the low field critical current and ac loss properties of niobium-tin thin films and layered composites fabricated by electron-beam coevaporation are presented. Particular emphasis is placed upon determining the suitability of this material for use as a conductor in a superconducting power transmission line. Chapter I contains a summary of this work and its major results together with an introduction to the scientific and engineering concepts associated with a superconducting power transmission line. Chapter II is a discussion of the physics of current transport and the associated loss mechanisms in a type-II superconductor. Chapter III gives the details of the electron-beam coevaporation technique developed to fabricate the samples for this study. Also discussed in this chapter are the effects of the evaporation conditions on the growth morphology of the niobium-tin films. Chapter IV presents the details of the experimental techniques developed to measure the ac loss and critical current in these samples as a function of temperature. Chapter V shows the dependence of the critical current of these films and composites on temperature, magnetic field, and on the number of artificially introduced pinning centers in the layered composites. Experimental results are also presented concerning the stability of these conductors against flux jumps. Chapter VI is a discussion of the ac losses in these samples. Detailed comparisons are made between the measured loss and the predictions of the critical state model

  7. Using low-field NMR to infer the physical properties of glassy oligosaccharide/water mixtures.

    Science.gov (United States)

    Aeberhardt, Kasia; Bui, Quang D; Normand, Valéry

    2007-03-01

    Low-field NMR (LF-NMR) is usually used as an analytical technique, for instance, to determine water and oil contents. For this application, no attempt is made to understand the physical origin of the data. Here we build a physical model to explain the five fit parameters of the conventional free induction decay (FID) for glassy oligosaccharide/water mixtures. The amplitudes of the signals from low-mobility and high-mobility protons correspond to the density of oligosaccharide protons and water protons, respectively. The relaxation time of the high-mobility protons is described using a statistical model for the probability that oligosaccharide hydroxyl groups form multiple hydrogen bonds. The variation of energy of the hydrogen bond is calculated from the average bond distance and the average angle contribution. Applying the model to experimental data shows that hydrogen atoms screen the water oxygen atoms when two water molecules solvate a single hydroxyl group. Furthermore, the relaxation time of the oligosaccharide protons is independent of its molecular weight and the water content. Finally, inversion of the FID using the inverse Laplace transform gives the continuous spectrum of relaxation times, which is a fingerprint of the oligosaccharide.

  8. Low-field STIR imaging of avascular necrosis, marrow edema, and infarction

    International Nuclear Information System (INIS)

    Porter, B.A.; Schwartz, A.N.; Olson, D.O.

    1987-01-01

    Based on 12 months experience with low-field (0.15-T) short-T1 inversion recovery (STIR) imaging, the authors replaced T2-weighted spin echo (T2SE) images with STIR for avascular necrosis (AVN). With STIR (repetition time 1,600 echo time 36, inversion time 100, 2 Avg, 256 x 128), fat is black and edema or joint fluid is bright white; 14 contiguous images take less than 7 minutes and have much greater contrast than T1 or T2 SE images. MR examinations of 36 patients with suspected AVN, marrow edema, or infarction were reviewed. AVN was equally well diagnosed with T1 SE and STIR in 16 of 16 patients. However, small effusions and the extent of marrow edema or infarction were better delineated on STIR. Joints with effusions were almost always symptomatic. Asymptomatic AVN was detected and confirmed by pressure measurements. AVN or asymptomatic marrow infarction was detected in four of six renal transplant patients. Serial STIR imaging may allow clinical monitoring of AVN. STIR improves detection of effusion, permits shorter imaging time, and can replace T2SE for AVN

  9. Pulsed magnetic field generation suited for low-field unilateral nuclear magnetic resonance systems

    Science.gov (United States)

    Gaunkar, Neelam Prabhu; Selvaraj, Jayaprakash; Theh, Wei-Shen; Weber, Robert; Mina, Mani

    2018-05-01

    Pulsed magnetic fields can be used to provide instantaneous localized magnetic field variations. In presence of static fields, pulsed field variations are often used to apply torques and in-effect to measure behavior of magnetic moments in different states. In this work, the design and experimental performance of a pulsed magnetic field generator suited for low static field nuclear magnetic resonance (NMR) applications is presented. One of the challenges of low bias field NMR measurements is low signal to noise ratio due to the comparable nature of the bias field and the pulsed field. Therefore, a circuit is designed to apply pulsed currents through an inductive load, leading to generation of pulsed magnetic fields which can temporarily overpower the effect of the bias field on magnetic moments. The designed circuit will be tuned to operate at the precession frequency of 1H (protons) placed in a bias field produced by permanent magnets. The designed circuit parameters may be tuned to operate under different bias conditions. Therefore, low field NMR measurements can be performed for different bias fields. Circuit simulations were used to determine design parameters, corresponding experimental measurements will be presented in this work.

  10. Estimation of diffusion coefficients in bitumen solvent mixtures as derived from low field NMR spectra

    International Nuclear Information System (INIS)

    Wen, Y.; Bryan, J.; Kantzas, A.

    2005-01-01

    Use of solvents for the extraction of heavy oil and bitumen appears to be an increasingly feasible technology. Both vapour extraction and direct solvent injection are considered for conventional exploration and production schemes, while solvent dilution of bitumen is a standard technique in oil sands mining. Mass transfer between solvent and bitumen is a poorly understood process. In some cases, it is totally ignored compared to viscous force effects. In other cases, phenomenological estimations of diffusion and dispersion coefficients are used. Low field NMR has been used successfully in determining both solvent content and viscosity reduction in heavy oil and bitumen mixtures with various solvents. As a solvent comes into contact with a heavy oil or bitumen sample, the mobility of hydrogen bearing molecules of both solvent and oil changes. These changes are detectable through changes in the NMR relaxation characteristics of both solvent and oil. Relaxation changes can then be correlated to mass flux and concentration changes. Based on Fick's Second Law, a diffusion coefficient, which is independent of concentration, was calculated against three oils and six solvents. (author)

  11. Novel 1H low field nuclear magnetic resonance applications for the field of biodiesel

    Science.gov (United States)

    2013-01-01

    Background Biodiesel production has increased dramatically over the last decade, raising the need for new rapid and non-destructive analytical tools and technologies. 1H Low Field Nuclear Magnetic Resonance (LF-NMR) applications, which offer great potential to the field of biodiesel, have been developed by the Phyto Lipid Biotechnology Lab research team in the last few years. Results Supervised and un-supervised chemometric tools are suggested for screening new alternative biodiesel feedstocks according to oil content and viscosity. The tools allowed assignment into viscosity groups of biodiesel-petrodiesel samples whose viscosity is unknown, and uncovered biodiesel samples that have residues of unreacted acylglycerol and/or methanol, and poorly separated and cleaned glycerol and water. In the case of composite materials, relaxation time distribution, and cross-correlation methods were successfully applied to differentiate components. Continuous distributed methods were also applied to calculate the yield of the transesterification reaction, and thus monitor the progress of the common and in-situ transesterification reactions, offering a tool for optimization of reaction parameters. Conclusions Comprehensive applied tools are detailed for the characterization of new alternative biodiesel resources in their whole conformation, monitoring of the biodiesel transesterification reaction, and quality evaluation of the final product, using a non-invasive and non-destructive technology that is new to the biodiesel research area. A new integrated computational-experimental approach for analysis of 1H LF-NMR relaxometry data is also presented, suggesting improved solution stability and peak resolution. PMID:23590829

  12. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  13. A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre

    OpenAIRE

    Roopal, Dr.; Bisht, Vandana

    2018-01-01

    Background: A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre.Methods: This prospective study was conducted among 100 women at tertiary care centre, Haldwani, Nainital. Patients were divided in to two groups. Group A (n=50)-post placental insertion within 10 minutes of delivery of placenta. Group B (n=50)-Interval insertion after 6 weeks of delivery. Both groups were compared in terms of pain abdomen, bleeding, missing thread, expulsion,...

  14. Central Solenoid Insert Technical Specification

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, Nicolai N [ORNL; Smirnov, Alexandre [ORNL

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  15. Tire deflation device

    Science.gov (United States)

    Barker, Stacey G [Idaho Falls, ID

    2010-01-05

    A tire deflation device includes (1) a component having a plurality of bores, (2) a plurality of spikes removably insertable into the plurality of bores and (3) a keeper within each among the plurality of bores, the keeper being configured to contact a sidewall surface of a spike among the plurality of spikes and to exert force upon the sidewall surface. In an embodiment, the tire deflation device includes (a) a component including a bore in a material, the bore including a receiving region, a sidewall surface and a base surface, (b) a channel extending from the sidewall surface into the material, (c) a keeper having a first section housed within the channel and a second section which extends past the sidewall surface into the receiving region, and (d) a spike removably insertable into the bore.

  16. Low-field nuclear magnetic resonance characterization of organic content in shales

    Science.gov (United States)

    Washburn, Kathryn E.; Birdwell, Justin E.; Seymour, Joseph D.; Kirkland, Catherine; Vogt, Sarah J.

    2013-01-01

    Low-field nuclear magnetic resonance (LF-NMR) relaxometry is a non-invasive technique commonly used to assess hydrogen-bearing fluids in petroleum reservoir rocks. Longitudinal T1 and transverse T2 relaxation time measurements made using LF-NMR on conventional reservoir systems provides information on rock porosity, pore size distributions, and fluid types and saturations in some cases. Recent improvements in LF-SNMR instrument electronics have made it possible to apply these methods to assess highly viscous and even solid organic phases within reservoir rocks. T1 and T2 relaxation responses behave very differently in solids and liquids, therefore the relationship between these two modes of relaxation can be used to differentiate organic phases in rock samples or to characterize extracted organic materials. Using T1-T2 correlation data, organic components present in shales, such as kerogen and bitumen, can be examined in laboratory relaxometry measurements. In addition, implementation of a solid-echo pulse sequence to refocus some types of T2 relaxation during correlation measurements allows for improved resolution of solid phase photons. LF-NMR measurements of T1 and T2 relaxation time correlations were carried out on raw oil shale samples from resources around the world. These shales vary widely in mineralogy, total organic carbon (TOC) content and kerogen type. NMR results were correlcated with Leco TOC and geochemical data obtained from Rock-Eval. There is excellent correlation between NMR data and programmed pyrolysis parameters, particularly TOC and S2, and predictive capability is also good. To better understand the NMR response, the 2D NMR spectra were compared to similar NMR measurements made using high-field (HF) NMR equipment.

  17. Static and dynamic evaluation of pelvic floor disorders with an open low-field tilting magnet

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Pastorelli, D.; Squillaci, E.; Funel, V.; Rascioni, M.; Meschini, A.; Salimbeni, C.; Sileri, P.; Franceschilli, L.; Simonetti, G.

    2013-01-01

    Aim: To assess the feasibility of magnetic resonance defaecography (MRD) in pelvic floor disorders using an open tilting magnet with a 0.25 T static field and to compare the results obtained from the same patient both in supine and orthostatic positions. Materials and methods: From May 2010 to November 2011, 49 symptomatic female subjects (mean age 43.5 years) were enrolled. All the patients underwent MRD in the supine and orthostatic positions using three-dimensional (3D) hybrid contrast-enhanced (HYCE) sequences and dynamic gradient echo (GE) T1-weighted sequences. All the patients underwent conventional defaecography (CD) to correlate both results. Two radiologists evaluated the examinations; inter and intra-observer concordance was measured. The results obtained in the two positions were compared between them and with CD. Results: The comparison between CD and MRD found statistically significant differences in the evaluation of anterior and posterior rectocoele during defaecation in both positions and of rectal prolapse under the pubo-coccygeal line (PCL) during evacuation, only in the supine position (versus MRD orthostatic: rectal prolapse p < 0.0001; anterior rectocoele p < 0.001; posterior rectocoele p = 0.008; versus CD: rectal prolapse p < 0.0001; anterior rectocoele p < 0.001; posterior rectocoele p = 0.01). The value of intra-observer intra-class correlation coefficient (ICC) ranged from good to excellent; the interobserver ICC from moderate to excellent. Conclusion: MRD is feasible with an open low-field tilting magnet, and it is more accurate in the orthostatic position than in the supine position to evaluate pelvic floor disorders

  18. Redesigning existing transcranial magnetic stimulation coils to reduce energy: application to low field magnetic stimulation

    Science.gov (United States)

    Wang, Boshuo; Shen, Michael R.; Deng, Zhi-De; Smith, J. Evan; Tharayil, Joseph J.; Gurrey, Clement J.; Gomez, Luis J.; Peterchev, Angel V.

    2018-06-01

    Objective. To present a systematic framework and exemplar for the development of a compact and energy-efficient coil that replicates the electric field (E-field) distribution induced by an existing transcranial magnetic stimulation coil. Approach. The E-field generated by a conventional low field magnetic stimulation (LFMS) coil was measured for a spherical head model and simulated in both spherical and realistic head models. Then, using a spherical head model and spatial harmonic decomposition, a spherical-shaped cap coil was synthesized such that its windings conformed to a spherical surface and replicated the E-field on the cortical surface while requiring less energy. A prototype coil was built and electrically characterized. The effect of constraining the windings to the upper half of the head was also explored via an alternative coil design. Main results. The LFMS E-field distribution resembled that of a large double-cone coil, with a peak field strength around 350 mV m‑1 in the cortex. The E-field distributions of the cap coil designs were validated against the original coil, with mean errors of 1%–3%. The cap coil required as little as 2% of the original coil energy and was significantly smaller in size. Significance. The redesigned LFMS coil is substantially smaller and more energy-efficient than the original, improving cost, power consumption, and portability. These improvements could facilitate deployment of LFMS in the clinic and potentially at home. This coil redesign approach can also be applied to other magnetic stimulation paradigms. Finally, the anatomically-accurate E-field simulation of LFMS can be used to interpret clinical LFMS data.

  19. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  20. Laparoscopic insertion of the Moss feeding tube.

    Science.gov (United States)

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  1. Reluctance device

    International Nuclear Information System (INIS)

    Claridge, A.N.; Smith, A.J.

    1983-01-01

    A reluctance device comprises two or more phases, each of which has a rotor mounted for rotation within a tubular member and an annular stator positioned externally of the tubular member. The rotor and the internal surface of the tubular member are each provided with aligned, axially spaced apart annular arrays of teeth, the teeth on the rotor confronting those on the tubular member in radially spaced apart relationship. The stator encloses a coil which, when electrically energised, creates a plurality of magnetic flux paths each of which extends radially between the rotor and stator via the confronting teeth and the tubular member, and axially along both the rotor and the portion of the stator located radially outwardly of the coil. The portion of the tubular member intermediate the teeth thereon is provided with a non-magnetic insert in order to resist the axial passage of magnetic flux therethrough. In one of the claims, the tubular member comprises a portion of a nuclear reactor which is adapted to contain a reactor control rod, the rotor constituting a portion of the drive mechanism for the control rod contained in operation within the tubular member. (author)

  2. Hall effect enhanced low-field sensitivity in a three-contact extraordinary magnetoresistance sensor

    KAUST Repository

    Sun, Jian; Kosel, Jü rgen

    2012-01-01

    be attributed to an additional influence coming from the Hall effect. Output sensitivities of 0.19 mV/T at zero-field and 0.2 mV/T at 0.01 T have been measured in the device, which is equivalent to the ones of the conventional EMR sensors with a bias of ∼0.04 T

  3. Electrical apparatus lockout device

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, R.

    1999-10-12

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards.

  4. Electrical apparatus lockout device

    International Nuclear Information System (INIS)

    Gonzales, R.

    1999-01-01

    A simple lockout device for electrical equipment equipped with recessed power blades is described. The device comprises a face-plate (12) having a threaded member (14) attached thereto and apertures suitable for accommodating the power blades of a piece of electrical equipment, an elastomeric nose (16) abutting the face-plate having a hole for passage of the threaded member therethrough and power blade apertures in registration with those of the face-plate, a block (20) having a recess (34) in its forward face for receiving at least a portion of the hose, a hole therein for receiving the threaded member and an integral extension (26) extending from its rear face. A thumb screw (22) suitable for turning with the hands and having internal threads suitable for engaging the threaded member attached to the face-plate is inserted into a passage in the integral extension to engage the threaded member in such a fashion that when the device is inserted over the recessed power blades of a piece of electrical equipment and the thumb screw (22) tightened, the elastomeric nose (16) is compressed between the face-plate (12) and the block (20) forcing it to expand laterally thereby securing the device in the recess and precluding the accidental or intentional energization of the piece of equipment by attachment of a power cord to the recessed power blades. Means are provided in the interval extension and the thumb screw for the attachment of a locking device (46) which will satisfy OSHA standards

  5. MR arthrography in chondromalacia patellae diagnosis on a low-field open magnet system.

    Science.gov (United States)

    Harman, Mustafa; Ipeksoy, Umit; Dogan, Ali; Arslan, Halil; Etlik, Omer

    2003-01-01

    The purpose of this study was to compare the diagnostic efficacy conventional MRI and MR arthrography (MRA) in the diagnosis of chondromalacia patella (CP) on a low-field open magnet system (LFOMS), correlated with arthroscopy. Forty-two patients (50 knees) with pain in the anterior part of the knee were prospectively examined with LFOMS, including T1-weighted, proton density-weighted and T2-weighted sequences. All were also examined T1-weighted MRI after intraarticular injection of dilue gadopentetate dimeglumine. Two observers, who reached a consensus interpretation, evaluated each imaging technique independently. Thirty-six of the 50 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity and accuracy of each imaging technique in the diagnosis of each stage of CP were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 16 facets were normal. Four (30%) of 13 grade 1 lesions were detected with T1. Four lesions (30%) with T2 and three lesions (23%) with proton-weighted images were detected. Seven (53%) of 13 grade 1 lesions were detected with MRA. Grade 2 abnormalities were diagnosed in two (33%) of six facets with proton density-weighted pulse sequences, two (33%) of six facets with T1-weighted pulse sequences, in three (50%) of six facets with T2-weighted pulse sequences, in five (83%) of six facets with MRA sequences. Grade 3 abnormalities were diagnosed in three (71%) of seven facets with proton density- and T1-weighted images, five (71%) of seven facets with T2-weighted pulse sequences, six (85%) of seven facets with MRA sequences. Grade 4 CP was detected with equal sensitivity with T1-, proton density- and T2-weighted pulse sequences, all showing seven (87%) of the eight lesions. MRA again showed these findings in all eight patients. All imaging techniques were insensitive to grade 1 lesions and highly sensitive to grade 4 lesion, so that no

  6. Impacts of pellets injected from the low-field side on plasma in ITER

    International Nuclear Information System (INIS)

    Wisitsorasak, A.; Onjun, T.

    2011-01-01

    Impacts of pellets injected from the low-field side (LFS) on plasma in ITER are investigated using the 1.5D BALDUR integrated predictive modeling code. In these simulations, the pellet ablation is described using the neutral gas shielding (NGS) model. The pellet ablation model is coupled with the plasma core transport model, which is a combination of the MMM95 anomalous transport model and NCLASS neoclassical transport model. The boundary conditions are assumed to be at the top of the pedestal, in which the pedestal parameters are predicted using a pedestal model based on the theoretical-based pedestal width scaling (either magnetic and flow shear stabilization width scaling, or flow shear stabilization width scaling, or normalized poloidal pressure width scaling) and the infinite-n ballooning mode pressure gradient limit. These pedestal models depend sensitively on the density at the top of the pedestal, which can be strongly influenced by the injection of pellets. The combination of the MMM95 and NCLASS models, together with the pedestal and NGS models, is used to simulate the time evolution of the plasma current, ion and electron temperatures, and density profiles for ITER standard type-I ELMy H-mode discharges during the injection of LFS pellets. It is found that the injection of pellets results in a complicated plasma scenario, especially in the outer region of the plasma and the plasma conditions at the boundary in which the pellet has an impact on increasing the plasma edge density, but reducing the plasma edge temperature. The LFS pellet has a stronger impact on the edge as compared to the center. For fusion performance, the pellet can result in either enhancement or degradation, depending sensitively on the pellet parameters; such as the pellet size, pellet velocity, and pellet frequency. For example, when a series of deuterium pellets with a size of 0.5 cm, velocity of 1 km/s, and frequency of 2 Hz are injected into the ITER plasma from the LFS, the

  7. Monitoring of organic contaminants in sediments using low field proton nuclear magnetic resonance

    Science.gov (United States)

    Zhang, Chi; Rupert, Yuri

    2016-04-01

    The effective monitoring of soils and groundwater contaminated with organic compounds is an important goal of many environmental restoration efforts. Recent geophysical methods such as electrical resistivity, complex conductivity, and ground penetrating radar have been successfully applied to characterize organic contaminants in the subsurface and to monitor remediation process both in laboratory and in field. Low field proton nuclear magnetic resonance (NMR) is a geophysical tool sensitive to the molecular-scale physical and chemical environment of hydrogen-bearing fluids in geological materials and shows promise as a novel method for monitoring contaminant remediation. This laboratory research focuses on measurements on synthetic samples to determine the sensitivity of NMR to the presence of organic contaminants and improve understanding of relationships between NMR observables, hydrological properties of the sediments, and amount and state of contaminants in porous media. Toluene, a light non-aqueous phase liquid (LNAPL) has been selected as a representative organic contaminant. Three types of porous media (pure silica sands, montmorillonite clay, and various sand-clay mixtures with different sand/clay ratios) were prepared as synthetic sediments. NMR relaxation time (T2) and diffusion-relaxation (D - T2) correlation measurements were performed in each sediment saturated with water and toluene mixed fluid at assorted concentrations (0% toluene and 100% water, 1% toluene and 99% water, 5% toluene and 95% water, 25% toluene and 75% water, and 100% toluene and 0% water) to 1) understand the effect of different porous media on the NMR responses in each fluid mixture, 2) investigate the role of clay content on T2 relaxation of each fluid, 3) quantify the amount hydrocarbons in the presence of water in each sediment, and 4) resolve hydrocarbons from water in D - T2 map. Relationships between the compositions of porous media, hydrocarbon concentration, and hydraulic

  8. Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumours

    DEFF Research Database (Denmark)

    Kristensen, B.H.; Laursen, F.J.; Logager, V.

    2008-01-01

    Background and purpose: Magnetic resonance (MR) imaging is superior to computed tomography (CT) in radiotherapy of brain tumours. In this study an open low-field MR-simulator is evaluated in order to eliminate the cost of and time spent on additional CT scanning. Materials and methods: Eleven...

  9. Acute peripheral joint injury: cost and effectiveness of low-field-strength MR imaging--results of randomized controlled trial.

    NARCIS (Netherlands)

    Nikken, J.J.; Oei, E.H.; Ginai, A.Z.; Krestin, G.P.; Verhaar, J.A.N.; Vugt, A.B. van; Hunink, M.G.M.

    2005-01-01

    PURPOSE: To assess prospectively if a short imaging examination performed with low-field-strength dedicated magnetic resonance (MR) imaging in addition to radiography is effective and cost saving compared with the current diagnostic imaging strategy (radiography alone) in patients with recent acute

  10. Low field magnetic resonance imaging of the lumbar spine: Reliability of qualitative evaluation of disc and muscle parameters

    DEFF Research Database (Denmark)

    Sørensen, Joan Solgaard; Kjaer, Per; Jensen, Tue Secher

    2006-01-01

    PURPOSE: To determine the intra- and interobserver reliability in grading disc and muscle parameters using low-field magnetic resonance imaging (MRI). MATERIAL AND METHODS: MRI scans of 100 subjects representative of the general population were evaluated blindly by two radiologists. Criteria......: Convincing reliability was found in the evaluation of disc- and muscle-related MRI variables....

  11. Insertable fluid flow passage bridgepiece and method

    Science.gov (United States)

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  12. Utility Bill Insert for Wastewater Services

    Science.gov (United States)

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  13. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  14. Bulkhead insert for an internal combustion engine

    Science.gov (United States)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  15. Design and preliminary analysis of a vaginal inserter for speculum-free cervical cancer screening.

    Directory of Open Access Journals (Sweden)

    Mercy Nyamewaa Asiedu

    Full Text Available Cervical cancer screening usually requires use of a speculum to provide a clear view of the cervix. The speculum is one potential barrier to screening due to fear of pain, discomfort and embarrassment. The aim of this paper is to present and demonstrate the feasibility of a tampon-sized inserter and the POCkeT Colposcope, a miniature pen sized-colposcope, for comfortable, speculum-free and potentially self-colposcopy.We explored different designs using 3D computer-aided design (CAD software and performed mechanical testing simulations on each. Designs were rapid prototyped and tested using a custom vaginal phantom across a range of vaginal pressures and uterine tilts to select an optimal design. Two final designs were tested with fifteen volunteers to assess cervix visualization, comfort and usability compared to the speculum and the optimal design, the curved-tip inserter, was selected for testing in volunteers.We present a vaginal inserter as an alternative to the standard speculum for use with the POCkeT Colposcope. The device has a slim tubular body with a funnel-like curved tip measuring approximately 2.5 cm in diameter. The inserter has a channel through which a 2 megapixel (MP mini camera with LED illumination fits to enable image capture. Mechanical finite element testing simulations with an applied pressure of 15 cm H2O indicated a high factor of safety (90.9 for the inserter. Testing of the device with a custom vaginal phantom, across a range of supine vaginal pressures and uterine tilts (retroverted, anteverted and sideverted, demonstrated image capture with a visual area comparable to the speculum for a normal/axial positioned uteri and significantly better than the speculum for anteverted and sideverted uteri (p<0.00001. Volunteer studies with self-insertion and physician-assisted cervix image capture showed adequate cervix visualization for 83% of patients. In addition, questionnaire responses from volunteers indicated a 92

  16. Chronic insertional Achilles tendinopathy: surgical outcomes

    OpenAIRE

    Oshri, Yael; Palmanovich, Ezequiel; Brin, Yaron Shagra; Karpf, Ronen; Massarwe, Sabri; Kish, Benny; Nyska, Meir

    2012-01-01

    Background and objective: insertional Achilles tendinopathy is a common condition among athletes and joggers. One fifth of the injuries involves the insertion of the tendon. The etiology is either due to mechanical overuse related to sports activity, or a systemic inflammatory disease. The clinical appearance includes pain and movement restriction. The primary treatment is conservative. The surgery referred to in this study (Calcaneal Osteotomy) is performed by decompression of the posterior ...

  17. The influence of solid particles density on parameters of multijet insert

    Directory of Open Access Journals (Sweden)

    Z. Niedźwiedzki

    2008-10-01

    Full Text Available Some dependences between solid particles density, chosen geometry and exploitation parameters of multijet inserts and developmentof laminar motion in continuous multijet sedimentation process, are presented in this paper. Results are obtained from the analysis of the multijet sedimentation model considering development of laminar motion of the suspension in the multijet insert conduit of the settling tank. The range of the researches covered, in particular, quantities necessary for designing inserts of multijet settling tanks finding application in purifying suspended solids in casting processes. Discussed problem has practical and cognitive meanings and is a base for more efficient designing multijet settling tanks inserts applied in iron and steel industry. Application of most efficient construction and exploitation parameters allows designing devices of lower dimensions what is especially advantageous in casting works.

  18. Z-2 Threaded Insert Design and Testing

    Science.gov (United States)

    Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen

    2016-01-01

    NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

  19. Ultra-low power, highly uniform polymer memory by inserted multilayer graphene electrode

    International Nuclear Information System (INIS)

    Jang, Byung Chul; Kim, Jong Yun; Koo, Beom Jun; Yang, Sang Yoon; Choi, Sung-Yool; Seong, Hyejeong; Im, Sung Gap; Kim, Sung Kyu

    2015-01-01

    Filament type resistive random access memory (RRAM) based on polymer thin films is a promising device for next generation, flexible nonvolatile memory. However, the resistive switching nonuniformity and the high power consumption found in the general filament type RRAM devices present critical issues for practical memory applications. Here, we introduce a novel approach not only to reduce the power consumption but also to improve the resistive switching uniformity in RRAM devices based on poly(1,3,5-trimethyl-3,4,5-trivinyl cyclotrisiloxane) by inserting multilayer graphene (MLG) at the electrode/polymer interface. The resistive switching uniformity was thereby significantly improved, and the power consumption was markedly reduced by 250 times. Furthermore, the inserted MLG film enabled a transition of the resistive switching operation from unipolar resistive switching to bipolar resistive switching and induced self-compliance behavior. The findings of this study can pave the way toward a new area of application for graphene in electronic devices. (paper)

  20. One century of Kirschner wires and Kirschner wire insertion techniques : A historical review

    NARCIS (Netherlands)

    Franssen, Bas B. G. M.; Schuurman, Arnold H.; Van der Molen, Aebele Mink; Kon, Moshe

    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly

  1. Complications after implantation of a new-generation insertable cardiac monitor

    DEFF Research Database (Denmark)

    Diederichsen, Søren Zöga; Haugan, Ketil Jørgen; Højberg, Søren

    2017-01-01

    BACKGROUND: Insertable cardiac monitors (ICM) are leadless devices utilized in long-term monitoring of the heart rhythm. The implantation procedure of the new-generation ICMs is minimally invasive, but little experience exists regarding complications. We thus aimed to investigate adverse events (AE...

  2. Modeling the Insertion Mechanics of Flexible Neural Probes Coated with Sacrificial Polymers for Optimizing Probe Design

    Directory of Open Access Journals (Sweden)

    Sagar Singh

    2016-03-01

    Full Text Available Single-unit recording neural probes have significant advantages towards improving signal-to-noise ratio and specificity for signal acquisition in brain-to-computer interface devices. Long-term effectiveness is unfortunately limited by the chronic injury response, which has been linked to the mechanical mismatch between rigid probes and compliant brain tissue. Small, flexible microelectrodes may overcome this limitation, but insertion of these probes without buckling requires supporting elements such as a stiff coating with a biodegradable polymer. For these coated probes, there is a design trade-off between the potential for successful insertion into brain tissue and the degree of trauma generated by the insertion. The objective of this study was to develop and validate a finite element model (FEM to simulate insertion of coated neural probes of varying dimensions and material properties into brain tissue. Simulations were performed to predict the buckling and insertion forces during insertion of coated probes into a tissue phantom with material properties of brain. The simulations were validated with parallel experimental studies where probes were inserted into agarose tissue phantom, ex vivo chick embryonic brain tissue, and ex vivo rat brain tissue. Experiments were performed with uncoated copper wire and both uncoated and coated SU-8 photoresist and Parylene C probes. Model predictions were found to strongly agree with experimental results (<10% error. The ratio of the predicted buckling force-to-predicted insertion force, where a value greater than one would ideally be expected to result in successful insertion, was plotted against the actual success rate from experiments. A sigmoidal relationship was observed, with a ratio of 1.35 corresponding to equal probability of insertion and failure, and a ratio of 3.5 corresponding to a 100% success rate. This ratio was dubbed the “safety factor”, as it indicated the degree to which the coating

  3. Stability of highly shifted equilibria in a large aspect ratio low-field tokamak

    International Nuclear Information System (INIS)

    Gourdain, P.-A.; Leboeuf, J.-N.; Neches, R. Y.

    2007-01-01

    In the long run, the economics of fusion will dictate that reactors confine large plasma pressure rather efficiently. A possible route manifests itself as equilibria with large shift of the plasma magnetic axis. This shift compresses the flux surfaces on the outer part of the plasma, hereby increasing the allowable plasma pressure a machine can confine for a given toroidal magnetic field, which is the main cost of the device. As a first step toward a reactor, we propose investigating the stability of such configurations in a low magnetic field high aspect ratio machine. By focusing our arguments solely on the shape of the toroidal plasma current density profile we discuss the stability of highly shifted equilibria and their robustness to current profile variations that could occur in actual experiments. The evolution of the plasma parameters, as the beta poloidal is increased, is also examined to give a better understanding of the difference in performance between the various regimes

  4. Test manufacture of the canister insert 135

    International Nuclear Information System (INIS)

    Raiko, H.

    2005-10-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Foundries Jyvaeskylae Oy, in June 2004 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the second trial manufacture of this type of insert in Finland and, in total, the third test manufacture of insert by Metso Foundries Jyvaeskylae Oy. The result fulfilled all the requirements but the material mechanical properties of the cast material. The measured ultimate strength and elongation at rupture were lower than specified in the upper part of the cast. The reason for this was revealed in the metallurgical investigation of the cast material. The cast contained slag (dross). Avoiding the dross formation will be the most demanding challenge of the forthcoming development of the cast procedure. (orig.)

  5. Test manufacture of a canister insert

    International Nuclear Information System (INIS)

    Raiko, H.

    2004-11-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Paper Oy, Jyvaeskylae Foundry, in 2003 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the first trial manufacture of this type of insert in Finland and, in total, the second test manufacture of insert by Metso Paper. The result fulfilled all the requirements but the material mechanical properties and metallurgical structure of the cast material. The measured tensile strength, ultimate strength and elongation at rupture were lower than specified. The reason for this was revealed in the metallurgical investigation of the cast material. The nodulizing of the graphite was not occurred during the casting process according to the requirements. (orig.)

  6. Enhancement of Giant Magneto-Impedance in Series Co-Rich Microwires for Low-Field Sensing Applications

    Science.gov (United States)

    Jiang, S. D.; Eggers, T.; Thiabgoh, O.; Xing, D. W.; Fang, W. B.; Sun, J. F.; Srikanth, H.; Phan, M. H.

    2018-02-01

    Two soft ferromagnetic Co68.25Fe4.25Si12.25B15.25 microwires with the same diameter of 50 ± 1 μm but different fabrication processes were placed in series and in parallel circuit configurations to investigate their giant magneto-impedance (GMI) responses in a frequency range of 1-100 MHz for low-field sensing applications. We show that, while the low-field GMI response is significantly reduced in the parallel configuration, it is greatly enhanced in the series connection. These results suggest that a highly sensitive GMI sensor can be designed by arranging multi-wires in a saw-shaped fashion to optimize the sensing area, and soldered together in series connection to maintain the excellent magnetic field sensitivity.

  7. Preparation of polyurethane/montmorillonite nanocomposites by solution: characterization using low-field NMR and study of thermal stability

    International Nuclear Information System (INIS)

    Silva, Marcos Anacleto da; Tavares, Maria Ines B.

    2009-01-01

    Polyurethanes (PU) are important and versatile class of polymer materials, especially because of their desirable properties, such as high abrasion resistance, tear strength, excellent shock absorption, flexibility and elasticity. However, there also exist some disadvantages, for example, low thermal stability and barrier properties. To overcome the disadvantages, research on novel polyurethane/clay nanocomposites has been carried out. The investigation of the structure of polyurethane/clay nanocomposites has been mostly done by X-ray diffraction (XRD) and transmission electron microscopy (TEM). In this work, PU/clay films were prepared by solution, and the obtained nanocomposites were characterized by XRD and low-field nuclear magnetic resonance (NMR). Low field NMR measurements were able to provide important information on molecular dynamics of the polymeric nanocomposites PU/OMMT. In addition, they also confirmed the results obtained by XRD. The thermal stability was determined by thermogravimetric analysis (TGA). (author)

  8. Low field magnetoresistance in a 2D topological insulator based on wide HgTe quantum well.

    Science.gov (United States)

    Olshanetsky, E B; Kvon, Z D; Gusev, G M; Mikhailov, N N; Dvoretsky, S A

    2016-09-01

    Low field magnetoresistance is experimentally studied in a two-dimensional topological insulator (TI) in both diffusive and quasiballistic samples fabricated on top of a wide (14 nm) HgTe quantum well. In all cases a pronounced quasi-linear positive magnetoresistance is observed similar to that found previously in diffusive samples based on a narrow (8 nm) HgTe well. The experimental results are compared with the main existing theoretical models based on different types of disorder: sample edge roughness, nonmagnetic disorder in an otherwise coherent TI and metallic puddles due to locally trapped charges that act like local gate on the sample. The quasiballistic samples with resistance close to the expected quantized values also show a positive low-field magnetoresistance but with a pronounced admixture of mesoscopic effects.

  9. Low-field anomalous magnetic phase in the kagome-lattice shandite Co3Sn2S2

    OpenAIRE

    Kassem, Mohamed A.; Tabata, Yoshikazu; Waki, Takeshi; Nakamura, Hiroyuki

    2017-01-01

    The magnetization process of single crystals of the metallic kagom\\'e ferromagnet Co3Sn2S2 was carefully measured via magnetization and AC susceptibility. Field-dependent anomalous transitions in the magnetization indicate a low-field unconventionally ordered phase stabilized just below TC. The magnetic phase diagrams in applied fields along different crystallographic directions were determined. The magnetic relaxation process studied in frequencies covering five orders of magnitude from 0.01...

  10. Low-Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    low- cost and high-throughput was a key element proposed for this project, which we believe will be of significant benefit to the patients suffering...Award Number: W81XWH-15-1-0272 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s

  11. Low Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    greater gas polarizations and production amounts/ throughputs- benefiting in particular from the advent of com- pact, high-power, relatively low- cost ...Award Number: W81XWH-15-1-0271 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the

  12. Superconducting transition and low-field magnetoresistance of a niobium single crystal at 4.2 deg. K

    International Nuclear Information System (INIS)

    Perriot, G.

    1967-01-01

    We report the study of the electrical resistance of a niobium single crystal, at 4.2 deg. K, from the beginning of the superconductive transition to 80 kilo oersteds. Critical fieldsH c2 and H c3 have been determined. Influences on superconductive transition of current density, field-current angle, crystal orientation and magnetoresistance have been studied. Variation laws of low-field transverse and longitudinal magneto-resistances have been determined. (author) [fr

  13. Monitoring chemical reactions by low-field benchtop NMR at 45 MHz: pros and cons.

    Science.gov (United States)

    Silva Elipe, Maria Victoria; Milburn, Robert R

    2016-06-01

    Monitoring chemical reactions is the key to controlling chemical processes where NMR can provide support. High-field NMR gives detailed structural information on chemical compounds and reactions; however, it is expensive and complex to operate. Conversely, low-field NMR instruments are simple and relatively inexpensive alternatives. While low-field NMR does not provide the detailed information as the high-field instruments as a result of their smaller chemical shift dispersion and the complex secondary coupling, it remains of practical value as a process analytical technology (PAT) tool and is complimentary to other established methods, such as ReactIR and Raman spectroscopy. We have tested a picoSpin-45 (currently under ThermoFisher Scientific) benchtop NMR instrument to monitor three types of reactions by 1D (1) H NMR: a Fischer esterification, a Suzuki cross-coupling, and the formation of an oxime. The Fischer esterification is a relatively simple reaction run at high concentration and served as proof of concept. The Suzuki coupling is an example of a more complex, commonly used reaction involving overlapping signals. Finally, the oxime formation involved a reaction in two phases that cannot be monitored by other PAT tools. Here, we discuss the pros and cons of monitoring these reactions at a low-field of 45 MHz by 1D (1) H NMR. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Rotatable Small Permanent Magnet Array for Ultra-Low Field Nuclear Magnetic Resonance Instrumentation: A Concept Study.

    Science.gov (United States)

    Vogel, Michael W; Giorni, Andrea; Vegh, Viktor; Pellicer-Guridi, Ruben; Reutens, David C

    2016-01-01

    We studied the feasibility of generating the variable magnetic fields required for ultra-low field nuclear magnetic resonance relaxometry with dynamically adjustable permanent magnets. Our motivation was to substitute traditional electromagnets by distributed permanent magnets, increasing system portability. The finite element method (COMSOL®) was employed for the numerical study of a small permanent magnet array to calculate achievable magnetic field strength, homogeneity, switching time and magnetic forces. A manually operated prototype was simulated and constructed to validate the numerical approach and to verify the generated magnetic field. A concentric small permanent magnet array can be used to generate strong sample pre-polarisation and variable measurement fields for ultra-low field relaxometry via simple prescribed magnet rotations. Using the array, it is possible to achieve a pre-polarisation field strength above 100 mT and variable measurement fields ranging from 20-50 μT with 200 ppm absolute field homogeneity within a field-of-view of 5 x 5 x 5 cubic centimetres. A dynamic small permanent magnet array can generate multiple highly homogeneous magnetic fields required in ultra-low field nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) instruments. This design can significantly reduce the volume and energy requirements of traditional systems based on electromagnets, improving portability considerably.

  15. Evaluation of the SLAP lesion using a low-field (0.2T) magnetic resonance system

    International Nuclear Information System (INIS)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack

    2007-01-01

    To evaluate the diagnostic capabilities of the low-field (0.2T) magnetic resonance (MR) system in the detection of the superior labrum anterior to posterior (SLAP) lesion. One hundred fifty patients underwent magnetic resonance imaging of the shoulder over a 7-month period. Forty-six patients underwent arthroscopic surgery, and the surgical results were correlated with the findings of the MR imaging. Arthroscopic procedures were performed within a mean of 8 days after MR imaging. MR imaging of the shoulder was conducted as follows: shoulder coil; T1-weighted spin echo, coronal-oblique images; T2-weighted gradient echo, coronal-oblique and axial images; and T2-weighted spin echo, coronal oblique and sagittal-oblique images. Prospectively, one radiologist interpreted the MR images. The results of surgery were as follow: SLAP II in 26 shoulders, SLAP III in 1 shoulder, SLAP IV in 1 shoulder, normal labrum in 6 shoulder. For SLAP lesions with a higher grade than type 2, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the low-field MRI were 85.7%, 55.5%. 75%, 71%, and 74%, respectively. There was relatively good agreement for the comparison of the MR results obtained using a low-field MR system with the surgical findings for identifying SLAP lesions

  16. Comparative magnetic resonance imaging of renal space-occupying lesions with a high and a low field MRI system

    International Nuclear Information System (INIS)

    Gehl, H.B.; Lorch, H.; Amblank, O.B.M.; Engerhoff, B.; Weiss, H.D.

    1998-01-01

    Purpose: A prospective study of the diagnostic accuracy and image quality of two MRI systems in the detection of renal tumors was investigated. Materials and Methods: 34 patients with the clinical suspicion of a space-occupying renal lesion were examined by MRI with a low field (0.2 Tesla magnet) and a high field (1.5 Tesla magnet) for comparison. An 'informed' and a 'blind' observer evaluated all of the MR images. In addition, the signal-to-noise and contrast-to-noise ratios were evaluated as second quality parameters. Results: In 29 cases the results could be compared with a confirmed release diagnosis. Diagnostic accuracy was comparable with both systems (Sensitivity for both observer on LF apparatus: 83%, HF apparatus: 81%) although the signal-to-noise and contrast-to-noise ratios were significantly poorer at low field. Conclusions: The low field system in comparable to the high field MRI for detection and differentiation of renal space-occupying lesions. (orig.) [de

  17. The exploratory development of A self-made oral Gd-DTPA solution for low field MRCP in children

    International Nuclear Information System (INIS)

    Sheng Mao; Zhou Min; Gu Zhicheng; Wu Jizhi; Guo Wanliang; Ni Yongbiao; Fang Lin

    2010-01-01

    Objective: To evaluate the value of ingestion self-made Gd-DTPA solutin for low field magnetic resonance cholangiopancreatography (MRCP) (0.35T) in children. Methods: Phantom experiments were performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in low field MRCP. Twenty children suspected of celiac disease were performed with MRCP before and after ingestion Gd-DTPA solution. Signal intensity measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. Results: The selected Gd-DTPA concentration was 1.992 mmol/L. Ingestion of 80 ml solution eliminated or suppressed efficiently the gastroduodenal signal intensity, improving the MRCP image quality scores (P<0.01) significantly in children. Conclusion: 1.992 mmol/L self-made Gd-DTPA solutin can suppress or eliminate water signals from gastrointestinal tract and improve the quality of low field MRCP image in children. (authors)

  18. Orthopedic and interventional applications at low field MRI with horizontally open configuration

    International Nuclear Information System (INIS)

    Koskinen, S.K.; Parkkola, R.K.; Karhu, J.; Komu, M.E.S.; Kormano, M.J.

    1997-01-01

    The recently introduced horizontally open configuration imagers allow imaging of knee, hip or shoulder during whole range of motion, which is not possible in conventional MR imagers. Special joint motion devices can be used to provide accurate and reproducible studies. In cervical spine, functional MR imaging may be useful in evaluating alarligament stability in patients with late sequelae of a whiplash injury, and in patients with rheumatoid arthritis who are clinically suspected of having a cervical myelopathy or superior migration of the odontoid process. In shoulder, full range of motion abduction study may be helpful in assessing the supraspinatus tendon impingement. To evaluate patellofemoral malalignment, quadriceps loading is recommended since associated contracting muscles and related soft tissue structures can be evaluated. The position of the femoral head relative to the acetabulum during different positions can be assessed. Open-configuration scanners provide an access to patients during scanning procedure, and therefore permit interventional procedures to be monitored with MRI. Such interventions include aspiration cytology/biopsy and different drainage procedures. (orig.) [de

  19. RERTR-12 Insertion 1 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Lillo, M.A.; Chang, G.S.; Woolstenhulme, N.E.; Roth, G.A.; Wachs, D.M.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications. RERTR-12 insertion 1 includes the capsules irradiated during the first two irradiation cycles. These capsules include Z, X1, X2 and X3 capsules. The following report summarizes the life of the RERTR-12 insertion 1 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  20. RERTR-12 Insertion 2 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Chang, G.S.; Wachs, D.M.; Roth, G.A.; Woolstenhulme, N.E.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  1. Installation of the LHC experimental insertions

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the low-beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  2. INSTALLATION OF THE LHC EXPERIMENTAL INSERTIONS

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the Low-Beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  3. Compact insert design for cryogenic pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  4. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  5. Neutron absorber inserts for 55-gal drums

    International Nuclear Information System (INIS)

    Wilson, R.E.; Kim, Y.S.; Toffer, H.

    2000-01-01

    Transport and temporary storage of more than 200 g of fissile material in 55-gal drums at the Rocky Flats Environmental Technology Site (RFETS) have received significant attention during the cleanup mission. This paper discusses successful applications and results of extensive computer studies. Interim storage and movement of fissile material in excess of standard drum limits (200 g) in a safe configuration have been accomplished using special drum inserts. Such inserts have constrained the contents of a drum to two 4-ell bottles. The content of the bottles was limited to 600 g Pu or U in solution or a total of 1200 g for the entire drum. The inserts were a simple design constructed of stainless steel, forming a vertical cylindrical pipe into which two bottles, one on top of the other, could be centered in the drum. The remaining drum volume was configured to preclude any additional bottle placement external to the vertical cylinder. Such inserts in drums were successfully used in moving high-concentration solution from one building to another for chemical processing. Concern about the knowledge of fissile material concentration in bottles prompted another study for drum inserts. The past practice had been to load up to fourteen 4-ell bottles into 55-gal drums, provided the fissile material concentration was < 6 g fissile/ell, and the total drum contents of 200 g fissile was not exceeded. Only one determination of the solution concentration was needed. An extensive safety analysis concluded that a single measurement of bottle content could not ensure compliance with double-contingency-criterion requirements. A second determination of the bottle contents was required before bottles could be placed in a 55-gal drum. Al alternative to a dual-measurement protocol, which is for bolstering administrative control, was to develop an engineered safety feature that would eliminate expensive tests and administrative decisions. A drum insert design was evaluated that would

  6. Role of nanorods insertion layer in ZnO-based electrochemical metallization memory cell

    Science.gov (United States)

    Mangasa Simanjuntak, Firman; Singh, Pragya; Chandrasekaran, Sridhar; Juanda Lumbantoruan, Franky; Yang, Chih-Chieh; Huang, Chu-Jie; Lin, Chun-Chieh; Tseng, Tseung-Yuen

    2017-12-01

    An engineering nanorod array in a ZnO-based electrochemical metallization device for nonvolatile memory applications was investigated. A hydrothermally synthesized nanorod layer was inserted into a Cu/ZnO/ITO device structure. Another device was fabricated without nanorods for comparison, and this device demonstrated a diode-like behavior with no switching behavior at a low current compliance (CC). The switching became clear only when the CC was increased to 75 mA. The insertion of a nanorods layer induced switching characteristics at a low operation current and improve the endurance and retention performances. The morphology of the nanorods may control the switching characteristics. A forming-free electrochemical metallization memory device having long switching cycles (>104 cycles) with a sufficient memory window (103 times) for data storage application, good switching stability and sufficient retention was successfully fabricated by adjusting the morphology and defect concentration of the inserted nanorod layer. The nanorod layer not only contributed to inducing resistive switching characteristics but also acted as both a switching layer and a cation diffusion control layer.

  7. Split ring containment attachment device

    International Nuclear Information System (INIS)

    Sammel, A.G.

    1996-01-01

    A containment attachment device is described for operatively connecting a glovebag to plastic sheeting covering hazardous material. The device includes an inner split ring member connected on one end to a middle ring member wherein the free end of the split ring member is inserted through a slit in the plastic sheeting to captively engage a generally circular portion of the plastic sheeting. A collar potion having an outer ring portion is provided with fastening means for securing the device together wherein the glovebag is operatively connected to the collar portion. 5 figs

  8. Direct random insertion mutagenesis of Helicobacter pylori.

    NARCIS (Netherlands)

    Jonge, de R.; Bakker, D.; Vliet, van AH; Kuipers, E.J.; Vandenbroucke-Grauls, C.M.J.E.; Kusters, J.G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  9. Direct random insertion mutagenesis of Helicobacter pylori

    NARCIS (Netherlands)

    de Jonge, Ramon; Bakker, Dennis; van Vliet, Arnoud H. M.; Kuipers, Ernst J.; Vandenbroucke-Grauls, Christina M. J. E.; Kusters, Johannes G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  10. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Angiotensin Converting Enzyme Insertion/Deletion Gene Polymorphism: An Observational Study among Diabetic Hypertensive Subjects in Malaysia. ... Methods: The pharmacological effect of ACE inhibition on mean arterial pressure (MAP) and glomerular filtration rate (GFR) were observed among a total of 62 subjects for ...

  11. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  12. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  13. Patients Comprehension of Pharmaceutical Package Inserts ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research December 2015; 14 (12): ... Available online at http://www.tjpr.org ... patients/consumers about PPI. ... the perception of outpatients of Karachi about ... Do you store the medication at the temperature specified in the package insert ... drugs available in local market of Pakistan was.

  14. Orthopedic and interventional applications at low field MRI with horizontally open configuration

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, S.K.; Parkkola, R.K.; Karhu, J.; Komu, M.E.S.; Kormano, M.J. [Diagnostic Radiology, Turku Univ. Hospital (Finland)

    1997-10-01

    The recently introduced horizontally open configuration imagers allow imaging of knee, hip or shoulder during whole range of motion, which is not possible in conventional MR imagers. Special joint motion devices can be used to provide accurate and reproducible studies. In cervical spine, functional MR imaging may be useful in evaluating alarligament stability in patients with late sequelae of a whiplash injury, and in patients with rheumatoid arthritis who are clinically suspected of having a cervical myelopathy or superior migration of the odontoid process. In shoulder, full range of motion abduction study may be helpful in assessing the supraspinatus tendon impingement. To evaluate patellofemoral malalignment, quadriceps loading is recommended since associated contracting muscles and related soft tissue structures can be evaluated. The position of the femoral head relative to the acetabulum during different positions can be assessed. Open-configuration scanners provide an access to patients during scanning procedure, and therefore permit interventional procedures to be monitored with MRI. Such interventions include aspiration cytology/biopsy and different drainage procedures. (orig.) [Deutsch] Die kuerzlich eingefuehrten bildgebenden Systeme mit horizontal offener Konfiguration ermoeglichen die Darstellung von Knie, Huefte oder Schulter ueber den gesamten Bewegungsbereich, war bisher mit konventionellen MR-Systemen nicht moeglich. Fuer genauere und reproduzierbare Untersuchungen koennen spezielle Gelenkbewegungsgeraete verwendet werden. Bei der Halswirbelsaeule kann die funktionelle NMR-Darstellung im Hinblick auf die Beurteilung der Stabilitaet der Ligamenta alaria bei Patienten mit Spaetfolgen eines Schleudertraumas und bei Patienten mit rheumatoider Arthritis von Nutzen sein, wenn klinisch eine zervikale Myelopathie oder superiore migration des Dens axis vermutet wird. Bei der Schulter kann eine Abduktionsstudie des vollen Bewegungsbereichs bei der Beurteilung

  15. Intracesarean insertion of the Copper T380A versus 6 weeks postcesarean: a randomized clinical trial.

    Science.gov (United States)

    Lester, Felicia; Kakaire, Othman; Byamugisha, Josaphat; Averbach, Sarah; Fortin, Jennifer; Maurer, Rie; Goldberg, Alisa

    2015-03-01

    To compare rates of Copper T380A intrauterine device (IUD) utilization and satisfaction with immediate versus delayed IUD insertion after cesarean delivery in Kampala, Uganda. This study was a randomized clinical trial of women undergoing cesarean section who desired an IUD in Kampala, Uganda. Participants were randomly assigned to IUD insertion at the time of cesarean delivery or 6weeks afterward. The primary outcome was IUD utilization at 6months after delivery. Among 68 women who underwent randomization, an IUD was inserted in 100% (34/34) of the women in the immediate insertion group and in 53% (18/34) in the delayed group. IUD use at 6 months was higher in the immediate insertion group (93% vs. 50% after delayed insertion; pcontraceptive method compared to 44% (11/25) of nonusers (pWomen who chose not to be in the study or had the IUD removed often did so because of perceived husband or community disapproval. The 6-month utilization of an IUD after immediate insertion was significantly higher than after delayed insertion without increased complications. Contraceptive satisfaction was significantly higher among IUD users than nonusers. Community and husband attitudes influence IUD utilization and continuation in Kampala, Uganda. This work is important because it shows the safety and efficacy of providing IUDs during cesarean section in a setting where access to any healthcare, including contraception, can be extremely limited outside of childbearing and the consequences of an unintended, closely spaced pregnancy after a cesarean section can be life threatening. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Combined heart-kidney transplantation after total artificial heart insertion.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Multipurpose sampler device for liquid metal

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Holmes, J.T.

    1975-01-01

    A device for collecting samples or examining a flow of liquid metal is provided for use with such as a liquid-metal-cooled nuclear reactor. The sampler device includes a casing surrounded by an external heater for establishing an upper isothermal zone and a lower zone for heating the entering liquid metal. One of various inserts is suspended into the isothermal zone where it is surrounded by a shroud tube for directing liquid-metal flow from the heating zone into the top of the insert. Discharge flow from the insert gravitates through a helically wound tube in heat exchange contact with entering liquid-metal flow within the heating zone. The inserts comprise an overflow cup with upper and lower freeze seals, a filter for removing particulate matter, and a fixture for maintaining various sample materials in equilibrium with liquid-metal flow. (U.S.)

  18. Thermal coupling in low fields between the nuclear and electronic spins in Tm2+ doped CaF2

    International Nuclear Information System (INIS)

    Urbina, Cristian.

    1977-01-01

    It is shown that in a CaF 2 crystal doped with divalent thulium ions there is in low fields, a thermal coupling between the electron magnetic moments of Tm 2+ and the nuclear moments of 19 F. When these ones have been lowered down to temperature through dynamical high-field polarization and adiabatic demagnetization in succession the resulting polarisation of the formed ones can overstep their original polarization in high field. A trial is given to explain this Zeeman electronic energy cooling through nuclear Zeeman energy with invoking a thermal coupling between both systems through the spin-spin electronic interaction but no theoretical model is developed in view of a quantitative explanation of the dynamics of such a process. The magnetic resonance spectrum of Tm 2 + in low field is also investigated: an important shift and narrowing of the electron resonance line in low field are obtained when 19 F nuclei are very cold. This special spectral characters are explained as due to magnetic interactions between electronic impurities and the neighbouring 19 F nuclei and a theoretical model is developed (based on the local Weiss field approximation) which explains rather well the changes in the spectral shift as a function of the 19 F nucleus temperature. A second theoretical model has also been developed in view of a quantitative explanation of both the narrowing and shift of the spectrum, but its prediction disagree with the experimental results. It is shown that in low fieldsx it is possible to get rid of paramagnetic impurities after they have been reused as reducing agents for 19 F nucleus entropy populating at about 80%, a non magnetic metastable state with these impurities [fr

  19. Characteristics of Xanthosoma sagittifolium roots during cooking, using physicochemical analysis, uniaxial compression, multispectral imaging and low field NMR spectroscopy

    DEFF Research Database (Denmark)

    Boakye, Abena Achiaa; Gudjónsdóttir, María; Skytte, Jacob Lercke

    2017-01-01

    and white varieties of cocoyam roots were thus analysed by low field nuclear magnetic resonance relaxometry, multispectral imaging, uniaxial compression testing, and relevant physicochemical analysis in the current study. Both varieties had similar dry matter content, as well as physical and mechanical...... of that spectral region for rapid analysis of dry matter and water content of the roots. The small, but significant differences in the structural and gelatinization characteristics of the two varieties indicated that they may not be equally suited for further processing, e.g. to flours or starches. Processors thus...

  20. Free induction decay MR signal measurements toward ultra-low field MRI with an optically pumped atomic magnetometer.

    Science.gov (United States)

    Oida, Takenori; Kobayashi, Tetsuo

    2013-01-01

    Ultra-low field magnetic resonance imaging (ULF-MRI) has attracted attention because of its low running costs and minimum patient exposure. An optically pumped atomic magnetometer (OPAM) is a magnetic sensor with high sensitivity in the low frequency range, which does not require a cryogenic cooling system. In an effort to develop a ULF-MRI, we attempted to measure the free induction decay MR signals with an OPAM. We successfully detected the MR signals by combining an OPAM and a flux transformer, demonstrating the feasibility of the proposed system.

  1. The effects of amylose and starch phosphate on starch gel retrogradation studied by low-field 1H NMR relaxometry

    DEFF Research Database (Denmark)

    Thygesen, Lisbeth Garbrecht; Blennow, A.; Engelsen, S. B.

    2003-01-01

    Low-field Nuclear Magnetic Resonance (23 MHz) was used to study the effects of the degree of phosphorylation, the amylose content and the amylopectin chain length distribution on gel retrogradation for a set of 26 starches, six of which were of crystal polymorph type A, 18 of type B and two of type......) relaxation curves from the two measurements (day 1 and day 7) could be used as a simple, illustrative way of describing the retrogradation. Three different behaviours were identified: One group of samples (mostly potato starches) slowly changed from a soft to a more rigid gel from day 1 to 7. A second group...

  2. Low field anisotropic properties of a single crystals of superconducting YBa2Cu3O7-δ

    International Nuclear Information System (INIS)

    Hammann, J.; Ocio, M.; Vincent, E.; Bertinotti, A.; Luzet, D.

    1987-09-01

    Low field (0.4G≤H≤3G) magnetization measurements have been performed on small single crystals of superconducting YBa 2 Cu 3 O 7.δ using a SQUID magnetometer. They revealed anisotropic properties in the temperature dependences of the shielding and the Meissner effects. A sharp unique transition at 95 K is observed with the field parallel to c. In the perpendicular direction a second transition line seems to be crossed at T* = 84 K. This temperature T* remains constant in the range of fields investigated

  3. Low-field anomalous magnetic phase in the kagome-lattice shandite C o3S n2S2

    Science.gov (United States)

    Kassem, Mohamed A.; Tabata, Yoshikazu; Waki, Takeshi; Nakamura, Hiroyuki

    2017-07-01

    The magnetization process of single crystals of the metallic kagome ferromagnet C o3S n2S2 was carefully measured via magnetization and ac susceptibility. Field-dependent anomalous transitions observed in low fields indicate the presence of an unconventional magnetic phase just below the Curie temperature, TC. The magnetic phase diagrams in low magnetic fields along different crystallographic directions were determined for the first time. The magnetic relaxation measurements at various frequencies covering five orders of magnitude from 0.01 to 1000 Hz indicate markedly slow spin dynamics only in the anomalous phase with characteristic relaxation times longer than 10 s.

  4. Antisite disorder-induced low-field magnetoresistance in some frustrated Sr2FeMoO6

    International Nuclear Information System (INIS)

    Cai Tianyi; Ju Sheng; Li Zhenya

    2006-01-01

    Considering the existence of antiferromagnetic patches induced by the antisite disorder in ferrimagnetic Sr 2 FeMoO 6 , we have developed a resistor network model to account for the effects of the antisite disorder on the magnetoresistance in this material. It is proposed that the magnetic disorder resulting from the existence of frustration around the antiferromagnetic patches will be suppressed under the applied magnetic field and low-field magnetoresistance will be observed. For samples with low levels of antisite defects, the magnetoresistive behaviour may be strongly affected by the different degrees of magnetic inhomogeneity. Our calculated results are in agreement with experimental observations

  5. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  6. Development of a virtual reality haptic Veress needle insertion simulator for surgical skills training.

    Science.gov (United States)

    Okrainec, A; Farcas, M; Henao, O; Choy, I; Green, J; Fotoohi, M; Leslie, R; Wight, D; Karam, P; Gonzalez, N; Apkarian, J

    2009-01-01

    The Veress needle is the most commonly used technique for creating the pneumoperitoneum at the start of a laparoscopic surgical procedure. Inserting the Veress needle correctly is crucial since errors can cause significant harm to patients. Unfortunately, this technique can be difficult to teach since surgeons rely heavily on tactile feedback while advancing the needle through the various layers of the abdominal wall. This critical step in laparoscopy, therefore, can be challenging for novice trainees to learn without adequate opportunities to practice in a safe environment with no risk of injury to patients. To address this issue, we have successfully developed a prototype of a virtual reality haptic needle insertion simulator using the tactile feedback of 22 surgeons to set realistic haptic parameters. A survey of these surgeons concluded that our device appeared and felt realistic, and could potentially be a useful tool for teaching the proper technique of Veress needle insertion.

  7. Reactor shutdown device

    International Nuclear Information System (INIS)

    Matsumiya, Hirohito; Endo, Hiroshi; Tsuboi, Yasushi.

    1993-01-01

    The present invention concerns a reactor shutdown device capable of suppressing change of a core insertion amount relative to temperature change during normal operation and having a great extension amount due to thermal expansion and high mechanical strength. A control rod main body is contained vertically movably in a guide tube disposed in a reactor core. An extension member extends upward from the upper end of a control rod main body and suspends the control rod main body. A shrinkable member intervenes at a midway of the extension member and is made shrinkable. A temperature sensitive member contains coolants at the inside and surrounds the shrinkable member. Thus, if the temperature of external coolants rises abruptly, the shrinkable member is extended by thermal expansion of the coolants in the temperature sensitive member. Upon usual reactor startup, the coolants in the temperature sensitive member cause no substantial thermal expansion by temperature elevation from a cold shutdown temperature to a rated power operation temperature, and the shrinkable member maintains its original state, so that the control rod main body is not inserted into the reactor core. However, upon abrupt temperature elevation, the control rod main body is inserted into the reactor core. (I.S.)

  8. Agitation within Mk-42 insert caused by air sparge

    International Nuclear Information System (INIS)

    Ramsey, C.J.

    1991-01-01

    Dissolution of Rocky Flats Pu alloys and Pu metal using a ''nested insert'' configuration (One Well Insert (S-3352) inside the Mk-42 Insert) will require a Nuclear Safety Study, a major assumption of which will be that the annular dissolver is well-mixed. The ''well-mixed'' assumption was theoretically and experimentally supported for alloy dissolution using the Three Well Insert, but the present situation differs significantly. In the former case, the insert was directly exposed to the agitation induced by air sparging; in the case under consideration, the One Well Insert would be shielded by the Mk-42 Insert. In an effort to determine if the ''nested insert'' approach should be pursued, the past studies and technical literature have been surveyed and an attempt made to predict the extent of mixing and bulk circulation for a ''nested insert'' configuration in the presence of air sparging

  9. Software Defined Radio (SDR and Direct Digital Synthesizer (DDS for NMR/MRI Instruments at Low-Field

    Directory of Open Access Journals (Sweden)

    Aktham Asfour

    2013-11-01

    Full Text Available A proof-of-concept of the use of a fully digital radiofrequency (RF electronics for the design of dedicated Nuclear Magnetic Resonance (NMR systems at low-field (0.1 T is presented. This digital electronics is based on the use of three key elements: a Direct Digital Synthesizer (DDS for pulse generation, a Software Defined Radio (SDR for a digital receiving of NMR signals and a Digital Signal Processor (DSP for system control and for the generation of the gradient signals (pulse programmer. The SDR includes a direct analog-to-digital conversion and a Digital Down Conversion (digital quadrature demodulation, decimation filtering, processing gain…. The various aspects of the concept and of the realization are addressed with some details. These include both hardware design and software considerations. One of the underlying ideas is to enable such NMR systems to “enjoy” from existing advanced technology that have been realized in other research areas, especially in telecommunication domain. Another goal is to make these systems easy to build and replicate so as to help research groups in realizing dedicated NMR desktops for a large palette of new applications. We also would like to give readers an idea of the current trends in this field. The performances of the developed electronics are discussed throughout the paper. First FID (Free Induction Decay signals are also presented. Some development perspectives of our work in the area of low-field NMR/MRI will be finally addressed.

  10. Software Defined Radio (SDR) and Direct Digital Synthesizer (DDS) for NMR/MRI Instruments at Low-Field

    Science.gov (United States)

    Asfour, Aktham; Raoof, Kosai; Yonnet, Jean-Paul

    2013-01-01

    A proof-of-concept of the use of a fully digital radiofrequency (RF) electronics for the design of dedicated Nuclear Magnetic Resonance (NMR) systems at low-field (0.1 T) is presented. This digital electronics is based on the use of three key elements: a Direct Digital Synthesizer (DDS) for pulse generation, a Software Defined Radio (SDR) for a digital receiving of NMR signals and a Digital Signal Processor (DSP) for system control and for the generation of the gradient signals (pulse programmer). The SDR includes a direct analog-to-digital conversion and a Digital Down Conversion (digital quadrature demodulation, decimation filtering, processing gain…). The various aspects of the concept and of the realization are addressed with some details. These include both hardware design and software considerations. One of the underlying ideas is to enable such NMR systems to “enjoy” from existing advanced technology that have been realized in other research areas, especially in telecommunication domain. Another goal is to make these systems easy to build and replicate so as to help research groups in realizing dedicated NMR desktops for a large palette of new applications. We also would like to give readers an idea of the current trends in this field. The performances of the developed electronics are discussed throughout the paper. First FID (Free Induction Decay) signals are also presented. Some development perspectives of our work in the area of low-field NMR/MRI will be finally addressed. PMID:24287540

  11. Large low-field magnetoresistance of Fe{sub 3}O{sub 4} nanocrystal at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Shu, E-mail: mishu@buaa.edu.cn; Liu, Rui, E-mail: liurui1987@buaa.edu.cn; Li, Yuanyuan, E-mail: buaaliyuan@163.com; Xie, Yong, E-mail: xiey@buaa.edu.cn; Chen, Ziyu, E-mail: chenzy@buaa.edu.cn

    2017-04-15

    Superparamagnetic magnetite (Fe{sub 3}O{sub 4}) nanoparticles with an average size of 6.5 nm and good monodispersion were synthesized and investigated by X-ray diffraction, Raman spectrometer, transmission electron microscopy and vibrating sample magnetometer. Corresponding low-field magnetoresistance (LFMR) was tested by physical property measurement system. A quite high LFMR has been observed at room temperature. For examples, at a field of 3000 Oe, the LFMR is −3.5%, and when the field increases to 6000 Oe, the LFMR is up to −5.1%. The electron spin polarization was estimated at 25%. This result is superior to the previous reports showing the LFMR of no more than 2% at room temperature. The conduction mechanism is proposed to be the tunneling of conduction electrons between adjacent grains considering that the monodisperse nanocrystals may supply more grain boundaries increasing the tunneling probability, and consequently enhancing the overall magnetoresistance. - Highlights: • Superparamagnetic Fe3O4 nanoparticles with small size were synthesized. • A quite high LFMR has been observed at room temperature. • The more grain boundaries increase the tunneling probability and enlarge the MR. • The fast response of the sample increase the MR at a low field.

  12. Triboluminescent tamper-indicating device

    Science.gov (United States)

    Johnston, Roger G.; Garcia, Anthony R. E.

    2002-01-01

    A tamper-indicating device is described. The device has a transparent or translucent cylindrical body that includes triboluminescent material, and an outer opaque layer that prevents ambient light from entering. A chamber in the body holds an undeveloped piece of photographic film bearing an image. The device is assembled from two body members. One of the body members includes a recess for storing film and an optical assembly that can be adjusted to prevent light from passing through the assembly and exposing the film. To use the device with a hasp, the body members are positioned on opposite sides of a hasp, inserted through the hasp, and attached. The optical assembly is then manipulated to allow any light generated from the triboluminescent materials during a tampering activity that damages the device to reach the film and destroy the image on the film.

  13. Live insertion method used for main renewal

    International Nuclear Information System (INIS)

    Solkowitz, M.

    1992-01-01

    Baltimore Gas and Electric's pilot project using the live insertion method to replace a cast iron main provided excellent results. Its use on Eastern Avenue, a major state highway, was cost effective, provided gas service to customers during the work, required relatively short construction time and resulted in only minor traffic disruptions. Gas service transfers to the new main were done at customer convenience and resulted in outages of only a few hours per customer. This paper reports that the project involved inserting a 6-in. plastic line inside an existing 10-in. cast iron main. Miller Pipeline Corp., Indianapolis, supplier of the Insertec left-angle R right-angle live insertion method was contracted for the job. Miller technicians assisted BG and E forces by providing a load analysis of the main, a pushing machine and related supplies, foaming equipment and pipe cutting tools. Company forces were responsible for all preparatory work, including opening all excavations, installing bypasses, and fusing and testing the plastic pipe. Service transfers and renewals were also completed by company employees

  14. Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

    International Nuclear Information System (INIS)

    Minaif, Karine; Ajzen, Sergio; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Szejnfeld, Jacob; Ruano, Jose Maria Cordeiro; Noguti, Alberto Sinhiti

    2008-01-01

    Objective: to compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. Materials and methods: twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field magnetic resonance imaging was utilized as the golden-standard. Results: among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. Conclusion: low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging. (author)

  15. Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minaif, Karine; Ajzen, Sergio [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis]. E-mail: kminaif@uol.com.br; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Imaging Diagnosis. Unit of Abdomen; Ruano, Jose Maria Cordeiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of General Gynecology. Sector of Videlaparoscopy; Noguti, Alberto Sinhiti [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of General Gynecology

    2008-11-15

    Objective: to compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. Materials and methods: twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field magnetic resonance imaging was utilized as the golden-standard. Results: among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. Conclusion: low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging. (author)

  16. Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion.

    Science.gov (United States)

    Lo, Meng-chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B; Kaplan, Hilton M; Kohn, Joachim; Shreiber, David I; Zahn, Jeffrey D

    2015-04-01

    We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.

  17. Per-operative vibration analysis: a valuable tool for defining correct stem insertion: preliminary report.

    Science.gov (United States)

    Mulier, Michiel; Pastrav, Cesar; Van der Perre, Georges

    2008-01-01

    Defining the stem insertion end point during total hip replacement still relies on the surgeon's feeling. When a custom-made stem prosthesis with an optimal fit into the femoral canal is used, the risk of per-operative fractures is even greater than with standard prostheses. Vibration analysis is used in other clinical settings and has been tested as a means to detect optimal stem insertion in the laboratory. The first per-operative use of vibration analysis during non-cemented custom-made stem insertion in 30 patients is reported here. Thirty patients eligible for total hip replacement with uncemented stem prosthesis were included. The neck of the stem was connected with a shaker that emitted white noise as excitation signal and an impedance head that measured the frequency response. The response signal was sent to a computer that analyzed the frequency response function after each insertion phase. A technician present in the operating theatre but outside the laminated airflow provided feed-back to the surgeon. The correlation index between the frequency response function measured during the last two insertion hammering sessions was >0.99 in 86.7% of the cases. In four cases the surgeon stopped the insertion procedure because of a perceived risk of fracture. Two special cases illustrating the potential benefit of per-operative vibration analysis are described. The results of intra-operative vibration analysis indicate that this technique may be a useful tool assisting the orthopaedic surgeon in defining the insertion endpoint of the stem. The development of a more user-friendly device is therefore warranted.

  18. Clinical Application of Insertion Force Sensor System for Coil Embolization of Intracranial Aneurysms.

    Science.gov (United States)

    Matsubara, Noriaki; Miyachi, Shigeru; Izumi, Takashi; Yamada, Hiroyuki; Marui, Naoki; Ota, Keisuke; Tajima, Hayato; Shintai, Kazunori; Ito, Masashi; Imai, Tasuku; Nishihori, Masahiro; Wakabayashi, Toshihiko

    2017-09-01

    In endovascular embolization for intracranial aneurysms, it is important to properly control the coil insertion force. However, the force can only be subjectively detected by the subtle feedback experienced by neurointerventionists at their fingertips. The authors envisioned a system that would objectively sense and quantify that force. In this article, coil insertion force was measured in cases of intracranial aneurysm using this sensor, and its actual clinical application was investigated. The sensor consists of a hemostatic valve (Y-connector). A little flexure was intentionally added in the device, and it creates a bend in the delivery wire. The sensor measures the change in the position of the bent wire depending on the insertion force and translates it into a force value. Using this, embolization was performed for 10 unruptured intracranial aneurysms. The sensor adequately recorded the force, and it reflected the operators' usual clinical experience. The presence of the sensor did not affect the procedures. The sensor enabled the operators to objectively note and evaluate the insertion force and better cooperative handling was possible. Additionally, other members of the intervention team shared the information. Force records demonstrated the characteristic patterns according to every stage of coiling (framing, filling, and finishing). The force sensor system adequately measured coil insertion force in intracranial aneurysm coil embolization procedures. The safety of this sensor was demonstrated in clinical application for the limited number of patients. This system is useful adjunct for assisting during coil embolization for an intracranial aneurysm. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. MRI of intracerebral haematoma at low field (0.15T) using T2 dependent partial saturation sequences

    International Nuclear Information System (INIS)

    Bydder, G.M.; Pennock, J.M.; Porteous, R.; Dubowitz, L.M.S.; Gadian, D.G.; Young, I.R.

    1988-01-01

    Results of MRI at 0.15T in twelve successive patients with intracerebral haematoma are reviewed. Using T 2 weighted spin echo (SE) and partial saturation (PS without a refocussing 180 0 pulse) sequences, low intensity areas were seen in eleven of the twelve cases. These included central regions (three cases), a peripheral rim (seven cases) and more diffuse patterns involving the brainstem and cerebral hemispheres (two cases). One case initially displayed a peripheral rim and later a central low intensity region. Central low intensity regions were seen in acute, subacute, and chronic cases. Follow up in five cases displayed an increase in signal within the haematoma in three cases and a decrease in signal intensity in two cases. Low signal intensity areas can be seen within and around intracerebral haematomas imaged with T 2 weighted sequences at low field strength. (orig.)

  20. Characterization of moisture in acetylated and propionylated radiata pine using low-field nuclear magnetic resonance (LFNMR) relaxometry

    DEFF Research Database (Denmark)

    Beck, Greeley; Thybring, Emil Engelund; Thygesen, Lisbeth Garbrecht

    2018-01-01

    . A possible explanation is the counteracting effects of decreased hydrophilicity and reduced moisture content (MC) of these water populations at higher levels of acetylation. The evaluation of propionylation on WCW T2 data was complicated by peak splitting in the relaxation spectrum. Constant T2 values......Moisture in radiata pine (Pinus radiata D. Don) earlywood (EW), which was acetylated or propionylated to various degrees, was measured by low-field nuclear magnetic resonance (LFNMR) relaxometry. Spin-spin relaxation times (T2) were determined for fully saturated samples at 22 and -18°C. T2 values...... for EW lumen water increased with increasing acetylation weight percentage gain (WPG), perhaps caused by the less hydrophilic acetylated wood (AcW) surface. Cell wall water (WCW) and the water in pits and small voids also showed increasing T2 values as a function of WPG but with a weaker tendency...

  1. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  2. Atomistic Galois insertions for flow sensitive integrity

    DEFF Research Database (Denmark)

    Nielson, Flemming; Nielson, Hanne Riis

    2017-01-01

    Several program verification techniques assist in showing that software adheres to the required security policies. Such policies may be sensitive to the flow of execution and the verification may be supported by combinations of type systems and Hoare logics. However, this requires user assistance...... and to obtain full automation we shall explore the over-approximating nature of static analysis. We demonstrate that the use of atomistic Galois insertions constitutes a stable framework in which to obtain sound and fully automatic enforcement of flow sensitive integrity. The framework is illustrated...

  3. Radiographs and low field MRI (0.2T) as predictors of efficacy in a weight loss trial in obese women with knee osteoarthritis

    DEFF Research Database (Denmark)

    Gudbergsen, Henrik; Boesen, Mikael; Christensen, Robin

    2011-01-01

    To study the predictive value of baseline radiographs and low-field (0.2T) MRI scans for the symptomatic outcome of clinically significant weight loss in obese patients with knee osteoarthritis.......To study the predictive value of baseline radiographs and low-field (0.2T) MRI scans for the symptomatic outcome of clinically significant weight loss in obese patients with knee osteoarthritis....

  4. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  5. Comparison of the analgesic effects of oral tramadol and naproxen sodium on pain relief during IUD insertion.

    Science.gov (United States)

    Karabayirli, Safinaz; Ayrim, Aylin Aker; Muslu, Bunyamin

    2012-01-01

    To compare the analgesic efficacy of oral tramadol and naproxen sodium on pain during insertion of an intrauterine device (IUD). Randomized, double-blinded, clinical trial (Canadian Task Force classification I). University-affiliated hospital. Single-center. One hundred three patients scheduled for insertion of an IUD. Patients were randomly assigned to receive oral tramadol 50 mg capsules (n = 35) or naproxen sodium 550 mg tablets (n = 34) or placebo (n = 34) 1 hour before insertion of the IUD. After insertion of the IUD, pain intensity was evaluated using a visual analog scale (VAS, 0-10). Adverse effects, patient satisfaction with the medication, and preference for using it during future insertions were also recorded. The VAS scores were significantly different during IUD insertion among the 3 groups (p = .001). Pain scores in the tramadol group were significantly lower than in the naproxen group (p = .003), and the scores in the naproxen group was significantly lower than in the control group (p = .001). Patient satisfaction with the medication and preference for its future use were significantly lower in the control group than in the other 2 groups (p = .001). Prophylactic analgesia using 50 mg tramadol and 550 mg naproxen, delivered orally, can be used to relieve pain during IUD insertion. However, tramadol capsules were found to be more effective than naproxen tablets. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  6. Microfluidic device for drug delivery

    Science.gov (United States)

    Beebe, David J. (Inventor); MacDonald, Michael J. (Inventor); Eddington, David T. (Inventor); Mensing, Glennys A. (Inventor)

    2010-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  7. Laser decontamination device

    International Nuclear Information System (INIS)

    Michishita, Shizuo; Akagawa, Katsuhiko.

    1997-01-01

    One end of an optical fiber inserted into an inner cylinder is opposed to a wall surface to be decontaminated, and an opened top end of an intermediate cylinder circumferentially surrounding the inner cylinder is tightly in contact with the wall surface to be decontaminated, an open end of an outer cylinder circumferentially surrounding the intermediate cylinder is tightly in contact with the wall surface to be decontaminated. Dust removing holes are perforated in the vicinity of the top end of the intermediate cylinder while being in communication with the inside and the outside of the intermediate cylinder, and one end of an air supply tube is in communication with the space between the outer circumferential surface of the inner cylinder and the inner circumferential surface of the intermediate cylinder. The other end of the air supply tube is connected to an air supply device, one end of a sucking tube is in communication with the space between the outer circumferential surface of the intermediate cylinder and the inner circumferential surface of the outer cylinder, the other end of the sucking tube is connected to a sucking device, and the other end of the optical fiber is connected to a laser generation device. The laser generation device is operated while determining the air sucking amount increased than the air supply amount, the materials deposited on the wall surface are crushed and peeled off, and the peeled off materials are transferred by air flow to a filter and collected. (N.H.)

  8. Timing of Etonogestrel Implant Insertion After Dilation and Evacuation: A Randomized Controlled Trial.

    Science.gov (United States)

    Cowett, Allison A; Ali, Rose; Cooper, Mary A; Evans, Mark; Conzuelo, Gabriel; Cremer, Miriam

    2018-05-01

    To compare the 6-month use rate of the etonogestrel implant placed immediately after dilation and evacuation (D&E) with placement 2-4 weeks postprocedure. This is a randomized controlled trial of women seeking abortion between 14 0/7 and 23 5/7 weeks of gestation and desiring the etonogestrel contraceptive implant at an urban family planning clinic. Participants were randomized to device insertion immediately after the D&E compared with delayed insertion in 2-4 weeks. The primary outcome was implant use rate at 6 months after insertion and was determined by follow-up phone interviews. Secondary outcomes included repeat pregnancy rates and method satisfaction. The sample size of 120 participants was calculated based on a power of 0.80 to demonstrate a 20% difference in implant use rates between groups assuming 40% of women overall are not using the device 6 months after the procedure. Between November 2015 and October 2016, 148 participants were enrolled. Seventy-three participants (49.3%) were randomized to and underwent immediate implant insertion after D&E. The remaining 75 (50.6%) were randomized to delayed insertion. There were no significant differences in sociodemographic characteristics between the groups. Placement rate was 100% in the immediate group compared with 42.7% in the delayed group (P<.01). At 6 months, 40 of 43 (93%) women from the immediate group who completed follow-up continued use of the implant, whereas 19 of 30 (63.3%) women from the delayed group who completed follow-up were using the device (P=.002). Follow-up rates were low at 58.9% in the immediate group compared with 40.0% in the delayed group. Women were more likely to be using the etonogestrel implant at 6 months after D&E if they underwent immediate compared with delayed insertion. The very high loss to follow-up rate makes it difficult to draw conclusions about acceptability of the device and pregnancy rates. ClinicalTrials.gov, 02037919.

  9. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  10. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  11. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  12. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  13. Targeted gene insertion for molecular medicine.

    Science.gov (United States)

    Voigt, Katrin; Izsvák, Zsuzsanna; Ivics, Zoltán

    2008-11-01

    Genomic insertion of a functional gene together with suitable transcriptional regulatory elements is often required for long-term therapeutical benefit in gene therapy for several genetic diseases. A variety of integrating vectors for gene delivery exist. Some of them exhibit random genomic integration, whereas others have integration preferences based on attributes of the targeted site, such as primary DNA sequence and physical structure of the DNA, or through tethering to certain DNA sequences by host-encoded cellular factors. Uncontrolled genomic insertion bears the risk of the transgene being silenced due to chromosomal position effects, and can lead to genotoxic effects due to mutagenesis of cellular genes. None of the vector systems currently used in either preclinical experiments or clinical trials displays sufficient preferences for target DNA sequences that would ensure appropriate and reliable expression of the transgene and simultaneously prevent hazardous side effects. We review in this paper the advantages and disadvantages of both viral and non-viral gene delivery technologies, discuss mechanisms of target site selection of integrating genetic elements (viruses and transposons), and suggest distinct molecular strategies for targeted gene delivery.

  14. Cigarette Mouth Insertion Depths Among Chinese Smokers

    Directory of Open Access Journals (Sweden)

    Hu Q

    2014-12-01

    Full Text Available Vent blocking - where filter ventilation holes are intentionally or unintentionally, partly or completely covered by smokers’ lips during smoking - is an aspect of smoking behavior which can alter mainstream smoke yields. This study was designed to determine if, and to what extent ventilation holes were blocked by smokers’ lips in two cohorts of Chinese smokers. In this study, two groups of samples were collected. One group (1742 butts was collected randomly from public places in six chosen cities. Another (1037 butts was obtained by collecting the butts from identified smokers in Kunming. In this paper, the mouth insertion depth among Chinese smokers was studied for the first time by a staining method employing ninhydrin in ethanol. The results indicate that Chinese smokers exhibit a mouth insertion depth ranging from 1 to 17 mm with an average value of 7.5 AA± 2 mm. In this study, 95% of the ventilated filters examined showed that the vent zone was neither completely nor partially covered by smokers’ lips.

  15. Safety analysis for reactivity insertion on ADS

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia S.; Velasquez, Carlos E.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Costa, Antonella L. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Barros, Graiciany de P. [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this work, an accelerator driven system (ADS) has been studied to fuel regeneration, partitioning and transmutation using fuel removed from LWR-spent fuel. This spent fuel was reprocessed by GANEX and then spiked with thorium. Monteburns 2.0 (MCNP5/ORIGEN 2.1) code was used to simulate burnup and neutronic parameters of the systems. However, these systems might be interrupted for some technical problems during few days or long periods to perform maintenance of accelerator systems without shutdown the fission system. Therefore, in this work, the aim was to investigate the nuclear fuel evolution in three different cases with reactivity insertions and variations in the functionality of the ADS. The evaluation has been performed for a burnup of 3 years, which are the most dangerous years in case of reactivity insertions. Therefore, in the first case the ADS during its burnup the external source (spallation source) is cutting off from the system several times during the first year of burnup. In the second case, it is simulated the reactor at different power from 0 (shutdown) to 1.5 times the 515MWt. The results shows the safety limits of the ADS for different situation. (author)

  16. Advances in ferrite microwave materials and devices

    International Nuclear Information System (INIS)

    Schloemann, Ernst

    2000-01-01

    The application of ferrites in non-reciprocal components is discussed, with the emphasis on broadband isolators and circulators. The performance of such devices may be characterized by the ratio f max /f min of the frequencies that define the edges of the frequency band, within which satisfactory performance has been achieved. For the best currently available devices this ratio is approx. 3 : 1, but larger values appear feasible according to a detailed analysis of the 'low-field, low-frequency loss' that limits the performance

  17. Effect of CuPc layer insertion on the memory performance of CdS nanocomposite diodes

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, S.K., E-mail: surya@pu.ac.in; Kaur, Ramneek; Jyoti

    2016-09-15

    Highlights: • CdS nanocomposite as an active layer investigated for memory device application. • Effect of copper phthalocyanine layer insertion on the memory performance studied. • Bipolar switching behaviour with high ON/OFF ratio ∼1.4 × 10{sup 4}. • Series resistance and interface states dominate the electrical properties of the device. - Abstract: In the present work, semiconductor diodes with CdS nanocomposite as an active layer have been fabricated and investigated for memory device applications. The effect of copper phthalocyanine (CuPc) layer insertion between the bottom electrode and CdS nanocomposite has been studied. I–V characteristics show electrical hysteresis behaviour vital for memory storage application. The as-fabricated devices exhibit bipolar switching behaviour with OFF to ON state transition at positive bias and vice versa. Device with CuPc layer exhibits I{sub ON}/I{sub OFF} ratio ∼ 1.4 × 10{sup 4}. Possible conduction mechanism has been described on the basis of theoretical current conduction models. The frequency dispersion capacitance, series resistance and conductance of the devices have been studied and discussed. At low frequency, the series resistance and the interface states dominate the electrical properties of the device. The results indicate that the multilayered devices open up the possibility of new generation non-volatile memory devices with low cost, high density and stability.

  18. Method Of Wire Insertion For Electric Machine Stators

    Science.gov (United States)

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  19. Measuring device for bending of beryllium reflector

    International Nuclear Information System (INIS)

    Nishida, Seiri; Sakamoto, Naoki.

    1994-01-01

    The device of the present invention can measure bending of a beryllium reflector formed in a reactor core of a nuclear reactor by a relatively easy operation. Namely, a sensor portion comprises a long-support that can be inserted to a fuel element-insertion hole disposed in the reactor and a plurality of distance sensors disposed in a longitudinal direction of the support. A supersonic wave sensor which is advantageous in the heat resistance, the size and the accuracy and can conduct measurement in water relatively easily is used as the distance sensors. However, other sensors, instead of the sensor described above, may also be used. The plurality of distance sensors detect the bending amount of the beryllium reflector in the longitudinal direction by such an easy operation of inserting such a sensor portion to the fuel element-insertion hole upon exchange of fuel elements. (I.S.)

  20. Multimodality imaging of the Essure tubal occlusion device

    International Nuclear Information System (INIS)

    Simpson, W.L.; Beitia, L.

    2012-01-01

    The Essure device is a permanent birth-control device, which is gaining popularity. The micro-inserts are composed of metallic elements that can be seen on radiography, computed tomography, ultrasound, and magnetic resonance imaging. Knowledge of the normal location and appearance of the Essure device will ensure appropriate patient care. The purpose of this review is to describe the Essure tubal occlusion device and illustrate its normal and abnormal appearance using various imaging methods.

  1. Hand-actuated spring clip insertion tool

    International Nuclear Information System (INIS)

    Cuba, G.W.

    1993-01-01

    A hand-actuated insertion tool includes a handle assembly, an elongated hollow tubular outer support tube, an elongated inner pull rod, and a coupling arrangement. The handle assembly has a first handle member and a second handle member pivoted to a member for movement between unactuated and actuated positions. The tube is attached in a fixed relation to a handle member. The rod is mounted within the tube for sliding movement relative thereto between home and retracted positions. The coupling arrangement pivotally connects the rod to the second handle member such that the rod will undergo sliding movement from the home position to the retracted positions relative to the tube as the second handle member is moved from the unactuated position to the actuated position adjacent to the first handle member. (author)

  2. MORPH INSERTION AND ALLOMORPHY IN OPTIMALITY THEORY

    Directory of Open Access Journals (Sweden)

    Eulalia Bonet

    2004-12-01

    Full Text Available The goal of this paper is to compare two different hypotheses about the insertion of morphs and allomorphy in Optimality Theory. One of them, the Morphs through Constraifits Hypothesis (MCH claims that the phonological realization of morphemes (morphs is introduced through language-particular constraints. The other hypothesis, the Morphs in the Input Hypothesis (MIH claims that the inputs to GEN contain al1 the relevant phonological information. It is shown that the MIH is clearly superior to the MCH in accounting for voicing neutralization in languages like Catalan. The two hypotheses seem to fare even in dealing with other phenomena, such as phonologically-conditioned allomorphy or OCP-triggered epenthesis vs. haplology in English possessives and plurals. Finally, although the MCH seems to be a simpler hypothesis for lexical exceptions, it is shown that, when certain aspects are taken into account, it runs into problems.

  3. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  4. Cassini-Huygens Nears Saturn Orbit Insertion

    Science.gov (United States)

    Showstack, Randy

    2004-06-01

    After nearly 7 years and a 3.5-billion-km, circuitous journey from Earth, the $3-billion Cassini-Huygens mission to Saturn and Titan-an international effort by NASA, the European Space Agency, and the Italian Space Agency-now is just days away from its critical Saturn orbit insertion. Scheduled for 30 June, this will begin the 4-years part of the mission to study the Saturnian system. At a 3 June briefing at NASA headquarters in Washington, D.C., Robert Mitchell, the Cassini program manager with the Jet Propulsion Laboratory in Pasadena, California, said that scientists involved with the program are feeling excited, relieved, and also a bit anxious as the Cassini-Huygens spacecraft draws near to the ringed planet and its system.

  5. Quench Performance of the LHC Insertion Magnets

    CERN Document Server

    Lasheras, N C; Siemko, A; Ostojic, R; Kirby, G

    2009-01-01

    After final installation in the LHC tunnel, the MQM and MQY quadrupole magnets of the LHC insertions are now being commissioned to their nominal currents. These two types of magnets operate at 1.9 K and 4.5 K and with nominal currents ranging from 3600 A to 5390 A. From the very first acceptance tests of the bare magnets coming from the manufacturers, they have been powered using different cycles, in different configurations, at different temperatures and in different tests facilities. In this paper we present the global results of these powering tests. We aim at separating common from individual features of these groups of magnets. Temperature dependence of the training, temperature margin, and ultimate current can be extracted from these tests. As these magnets are used to match the optics and the dispersion in the machine, the projected ultimate current at which they can be operated is critical in view of operation of LHC.

  6. Regulatory perspective on incomplete control rod insertions

    International Nuclear Information System (INIS)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff's understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required

  7. Bone suture anchor fixation in the lower extremity: a review of insertion principles and a comparative biomechanical evaluation.

    Science.gov (United States)

    Scranton, Pierce E; Lawhon, S Michael; McDermott, John E

    2005-07-01

    Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.

  8. Nondestructive prediction and visualization of plumpness in live Eriocheir sinensis using low-field 1 H magnetic resonance imaging.

    Science.gov (United States)

    Zhang, Hongcai; Mei, Jun; Chen, Shunsheng; Wu, Xugan

    2018-02-06

    The plumpness of hepatopancreas and gonad tissues in live Chinese mitten crabs (Eriocheir sinensis) depends on the grading scale and its commercial value. In this work, a low-field T 1 -weighted 1 H magnetic resonance imaging (LF- 1 H MRI) technique was developed to nondestructively analyze the plumpness of hepatopancreas and gonad tissues in live E. sinensis. Both male and female E. sinensis were characterized by two-dimensional (2D) LF- 1 H MRI. Moreover, a three-dimensional (3D) LF- 1 H MRI model that quantitatively integrated the total volume of lipid tissues in live E. sinensis was used. The results showed 2D LF- 1 H MRI could accurately discriminate the plumpness of hepatopancreas and gonad tissues in live E. sinensis. The results of the 3D LF- 1 H MRI model displayed that the lipid volume of E. sinensis could be used to quantify lipid accumulation in lipid tissues. LF- 1 H MRI technology was successfully developed to accurately discriminate the development of E. sinensis hepatopancreas and gonad tissues in a nondestructive manner, indicating its application potential in grading commercial live crabs or advising crab farmers on breeding and fattening processes. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  9. Passive shimming of the fringe field of a superconducting magnet for ultra-low field hyperpolarized noble gas MRI.

    Science.gov (United States)

    Parra-Robles, Juan; Cross, Albert R; Santyr, Giles E

    2005-05-01

    Hyperpolarized noble gases (HNGs) provide exciting possibilities for MR imaging at ultra-low magnetic field strengths (superconductive magnets used in clinical MR imaging can provide a stable magnetic field for this purpose. In addition to offering the benefit of HNG MR imaging alongside conventional high field proton MRI, this approach offers the other useful advantage of providing different field strengths at different distances from the magnet. However, the extremely strong field gradients associated with the fringe field present a major challenge for imaging since impractically high active shim currents would be required to achieve the necessary homogeneity. In this work, a simple passive shimming method based on the placement of a small number of ferromagnetic pieces is proposed to reduce the fringe field inhomogeneities to a level that can be corrected using standard active shims. The method explicitly takes into account the strong variations of the field over the volume of the ferromagnetic pieces used to shim. The method is used to obtain spectra in the fringe field of a high-field (1.89 T) superconducting magnet from hyperpolarized 129Xe gas samples at two different ultra-low field strengths (8.5 and 17 mT). The linewidths of spectra measured from imaging phantoms (30 Hz) indicate a homogeneity sufficient for MRI of the rat lung.

  10. Study of the method of water-injected meat identifying based on low-field nuclear magnetic resonance

    Science.gov (United States)

    Xu, Jianmei; Lin, Qing; Yang, Fang; Zheng, Zheng; Ai, Zhujun

    2018-01-01

    The aim of this study to apply low-field nuclear magnetic resonance technique was to study regular variation of the transverse relaxation spectral parameters of water-injected meat with the proportion of water injection. Based on this, the method of one-way ANOVA and discriminant analysis was used to analyse the differences between these parameters in the capacity of distinguishing water-injected proportion, and established a model for identifying water-injected meat. The results show that, except for T 21b, T 22e and T 23b, the other parameters of the T 2 relaxation spectrum changed regularly with the change of water-injected proportion. The ability of different parameters to distinguish water-injected proportion was different. Based on S, P 22 and T 23m as the prediction variable, the Fisher model and the Bayes model were established by discriminant analysis method, qualitative and quantitative classification of water-injected meat can be realized. The rate of correct discrimination of distinguished validation and cross validation were 88%, the model was stable.

  11. Magnetic nanoparticles with high specific absorption rate of electromagnetic energy at low field strength for hyperthermia therapy

    Science.gov (United States)

    Shubitidze, Fridon; Kekalo, Katsiaryna; Stigliano, Robert; Baker, Ian

    2015-03-01

    Magnetic nanoparticles (MNPs), referred to as the Dartmouth MNPs, which exhibit high specific absorption rate at low applied field strength have been developed for hyperthermia therapy applications. The MNPs consist of small (2-5 nm) single crystals of gamma-Fe2O3 with saccharide chains implanted in their crystalline structure, forming 20-40 nm flower-like aggregates with a hydrodynamic diameter of 110-120 nm. The MNPs form stable (>12 months) colloidal solutions in water and exhibit no hysteresis under an applied quasistatic magnetic field, and produce a significant amount of heat at field strengths as low as 100 Oe at 99-164 kHz. The MNP heating mechanisms under an alternating magnetic field (AMF) are discussed and analyzed quantitatively based on (a) the calculated multi-scale MNP interactions obtained using a three dimensional numerical model called the method of auxiliary sources, (b) measured MNP frequency spectra, and (c) quantified MNP friction losses based on magneto-viscous theory. The frequency responses and hysteresis curves of the Dartmouth MNPs are measured and compared to the modeled data. The specific absorption rate of the particles is measured at various AMF strengths and frequencies, and compared to commercially available MNPs. The comparisons demonstrate the superior heating properties of the Dartmouth MNPs at low field strengths (therapy to deeper tumors that were previously non-viable targets, potentially enabling the treatment of some of the most difficult cancers, such as pancreatic and rectal cancers, without damaging normal tissue.

  12. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  13. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  14. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  15. Files synchronization from a large number of insertions and deletions

    Science.gov (United States)

    Ellappan, Vijayan; Kumari, Savera

    2017-11-01

    Synchronization between different versions of files is becoming a major issue that most of the applications are facing. To make the applications more efficient a economical algorithm is developed from the previously used algorithm of “File Loading Algorithm”. I am extending this algorithm in three ways: First, dealing with non-binary files, Second backup is generated for uploaded files and lastly each files are synchronized with insertions and deletions. User can reconstruct file from the former file with minimizing the error and also provides interactive communication by eliminating the frequency without any disturbance. The drawback of previous system is overcome by using synchronization, in which multiple copies of each file/record is created and stored in backup database and is efficiently restored in case of any unwanted deletion or loss of data. That is, to introduce a protocol that user B may use to reconstruct file X from file Y with suitably low probability of error. Synchronization algorithms find numerous areas of use, including data storage, file sharing, source code control systems, and cloud applications. For example, cloud storage services such as Drop box synchronize between local copies and cloud backups each time users make changes to local versions. Similarly, synchronization tools are necessary in mobile devices. Specialized synchronization algorithms are used for video and sound editing. Synchronization tools are also capable of performing data duplication.

  16. Magnetic resonance imaging of hindfoot involvement in patients with spondyloarthritides: Comparison of low-field and high-field strength units

    Energy Technology Data Exchange (ETDEWEB)

    Eshed, Iris; Althoff, Christian E. [Department of Radiology, Charite Medical School, Berlin (Germany); Feist, Eugen [Department of Rheumatology and Clinical Immunology, Charite Medical School, Berlin (Germany); Minden, Kirsten [Helios Clinics, 2nd Children' s Hospital Berlin-Buch, Rheumatology Unit, Berlin (Germany); German Rheumatology Research Center, Berlin (Germany); Schink, Tania [Department of Medical Biometry, Charite Medical School, Berlin (Germany); Hamm, Bernd [Department of Radiology, Charite Medical School, Berlin (Germany); Hermann, Kay-Geert A. [Department of Radiology, Charite Medical School, Berlin (Germany)], E-mail: kgh@charite.de

    2008-01-15

    Objective: To compare MRI evaluation of a painful hindfoot of patients with spondyloarthritides (SpA) on low-field (0.2 T) versus high-field (1.5 T) MRI. Materials and methods: Patients with SpA and hindfoot pain were randomly referred to either high-field or low-field MRI. Twenty-seven patients were evaluated (male/female: 17:10; mean age: 39 {+-} 1.4 years). Fifteen patients were examined by low-field and 12 by high-field MRI. Two patients (evaluated by high-field MRI) were excluded. Images were separately read by two radiologists who later reached a consensus. In each patient the prevalence of erosions, fluid, synovitis or bone marrow edema of the hindfoot joints, tendinosis or tenosynovitis of tendons, enthesitis of the plantar fascia and Achilles tendon and retrocalcaneal bursitis were recorded. Clinical and demographic parameters were comparable between both groups. Results: MRI evaluation of joints and tendons of the hindfoot revealed no significant differences in patients with SpA groups for all parameters. Analyzing all joints or tendons together, there was no statistically significant difference between the two groups. Conclusion: Low-field and high-field MRI provide comparable information for evaluation of inflammatory hindfoot involvement. Thus, low-field MRI can be considered as a reliable diagnostic tool for the detection of hindfoot abnormalities in SpA patients.

  17. Magnetic resonance imaging of hindfoot involvement in patients with spondyloarthritides: Comparison of low-field and high-field strength units

    International Nuclear Information System (INIS)

    Eshed, Iris; Althoff, Christian E.; Feist, Eugen; Minden, Kirsten; Schink, Tania; Hamm, Bernd; Hermann, Kay-Geert A.

    2008-01-01

    Objective: To compare MRI evaluation of a painful hindfoot of patients with spondyloarthritides (SpA) on low-field (0.2 T) versus high-field (1.5 T) MRI. Materials and methods: Patients with SpA and hindfoot pain were randomly referred to either high-field or low-field MRI. Twenty-seven patients were evaluated (male/female: 17:10; mean age: 39 ± 1.4 years). Fifteen patients were examined by low-field and 12 by high-field MRI. Two patients (evaluated by high-field MRI) were excluded. Images were separately read by two radiologists who later reached a consensus. In each patient the prevalence of erosions, fluid, synovitis or bone marrow edema of the hindfoot joints, tendinosis or tenosynovitis of tendons, enthesitis of the plantar fascia and Achilles tendon and retrocalcaneal bursitis were recorded. Clinical and demographic parameters were comparable between both groups. Results: MRI evaluation of joints and tendons of the hindfoot revealed no significant differences in patients with SpA groups for all parameters. Analyzing all joints or tendons together, there was no statistically significant difference between the two groups. Conclusion: Low-field and high-field MRI provide comparable information for evaluation of inflammatory hindfoot involvement. Thus, low-field MRI can be considered as a reliable diagnostic tool for the detection of hindfoot abnormalities in SpA patients

  18. Glow discharging device

    International Nuclear Information System (INIS)

    Maeno, Katsuki; Kawasaki, Kozo; Hiratsuka, Hajime; Kawashima, Shuichi.

    1989-01-01

    In a thermonuclear device, etc. impurities adsorbed to inner walls of a vacuum vessel by glow discharge are released to clean the vacuum vessel for preventing intrusion of the impurities into plasmas. The object of the present invention is to minimize the capacity of a power source equipment for the glow discharge device to the least extent. That is, a stabilization resistance is connected in series between each of a plurality of anodes which are inserted and arranged at the inside of a vacuum vessel as a cathode and a power source respectively. The resistance value R is selected so as to satisfy the relation: R < (Vi - Vm)/Ii, in which Vi: glow discharge starting voltage, Vm: glow discharge keeping voltage, Ii: glow discharge starting current. Accordingly, if a voltage is applied from a power source to a plurality of anodes, scattering of electric discharge between the anodes can be suppressed and the effect of voltage drop during discharge by the stabilization resistance can be eliminated. As a result, it is possible to provide an economically advantageous glow discharge device with the capacity for the power source facility being to the least extent. (K.M.)

  19. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  20. Rubber glove wearing device

    International Nuclear Information System (INIS)

    Nozaki, Tatsuo; Takada, Kaoru.

    1994-01-01

    Rubber groves are attached each to an upper end of a glove putting vessel having an air-sucking hole on the bottom by enlarging an opening end of the rubber glove and turning back the inside to the outside. When the sucking device is operated, air in the glove putting device is sucked and the rubber glove is expanded by an atmospheric pressure. After expansion of the rubber glove to some extent, the sucking device is stopped, and presence or absence of failures of the rubber glove is confirmed by shrinkage of the rubber glove and by an indication value of a pressure gauge for detecting the pressure change in the vessel. Then, a hand is inserted to the expanded rubber glove, and a detaching switch in the vessel is pushed by a finger tip. A detaching piece at the upper end of the vessel is protruded outwardly to enlarge the turned-back portion of the rubber glove to easily release the rubber glove from the putting vessel, and the rubber glove is put on. This enables to wear the rubber glove and conduct failure test simultaneously. Further, a user can put on the rubber glove without touching the outside of the rubber glove. (I.N.)

  1. Stud manipulating device

    International Nuclear Information System (INIS)

    Bunyan, T.W.

    1980-01-01

    A device for inserting and removing studs from bores in a workpiece, for example a nuclear reactor vessel, comprises manipulating devices for operating on individual studs, each capable of tensioning a stud slackening a working nut on the stud, and subsequently removing the stud from the bore. A ring has dogs which can engage working nut recesses to interlock with the nut against relative rotation. Motors coupled to the ring rotate the working nut. A top nut is coupled to the motors to rotate the nut and screw it onto the stud. The top nut with other device parts can be raised and lowered on a tube by a hydraulic actuator. A hydraulic load cell between the top nut and a stool on the workpiece is pressurised to tension the stud by means of the top nut and thus facilitate rotation of the working nut when tightening or slackening. A dog clutch mechanism engages a stud end fitting against relative axial and rotational movement. The mechanism is raised and lowered on a guide member by an actuator. The mechanism has a tubular member and the drive coupling for the motors to the top nut includes a tubular member. Tubular members carry teeth which are engaged when the top nut is raised and the clutch mechanism is lowered, to provide a coupling between the motors and the mechanism for rotating the stud. (U.K.)

  2. Sampling inspection device

    International Nuclear Information System (INIS)

    Chiba, Keiichi.

    1996-01-01

    A holder is inserted to a holder guide, and is stopped at a position where one end of a hook disposed to the holder is not in contact with the holder guide (a position where hooks do not work). A cap incorporated with wiping paper is pushed up into a holder by a device rod with the wiping paper situated downwardly. The hooks of the holder are engaged to the grooves of the cap to secure the cap. The holder is moved to a predetermined place to wipe off the deposited materials on the surface of a vessel which contains radioactive wastes. Then, the holder is inserted to the holder guide, and is stopped at a position where the one end of the holder is raised. The securement of the gap is released, the cap is forced into a recovering cover by a discharging rod. The hooks of the recovering cover are caught by the grooves of the cap to secure the cap. Then, the cap is transported to a radioactivity measuring chamber. (I.N.)

  3. Enhanced electrical properties of oxide semiconductor thin-film transistors with high conductivity thin layer insertion for the channel region

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Cam Phu Thi; Raja, Jayapal; Kim, Sunbo; Jang, Kyungsoo; Le, Anh Huy Tuan; Lee, Youn-Jung; Yi, Junsin, E-mail: junsin@skku.edu

    2017-02-28

    Highlights: • The characteristics of thin film transistors using double active layers are examined. • Electrical characteristics have been improved for the double active layers devices. • The total trap density can be decreased by insert-ion of ultrathin ITO film. - Abstract: This study examined the performance and the stability of indium tin zinc oxide (ITZO) thin film transistors (TFTs) by inserting an ultra-thin indium tin oxide (ITO) layer at the active/insulator interface. The electrical properties of the double channel device (ITO thickness of 5 nm) were improved in comparison with the single channel ITZO or ITO devices. The TFT characteristics of the device with an ITO thickness of less than 5 nm were degraded due to the formation of an island-like morphology and the carriers scattering at the active/insulator interface. The 5 nm-thick ITO inserted ITZO TFTs (optimal condition) exhibited a superior field effect mobility (∼95 cm{sup 2}/V·s) compared with the ITZO-only TFTs (∼34 cm{sup 2}/V·s). The best characteristics of the TFT devices with double channel layer are due to the lowest surface roughness (0.14 nm) and contact angle (50.1°) that result in the highest hydrophicility, and the most effective adhesion at the surface. Furthermore, the threshold voltage shifts for the ITO/ITZO double layer device decreased to 0.80 and −2.39 V compared with 6.10 and −6.79 V (for the ITZO only device) under positive and negative bias stress, respectively. The falling rates of E{sub A} were 0.38 eV/V and 0.54 eV/V for the ITZO and ITO/ITZO bi-layer devices, respectively. The faster falling rate of the double channel devices suggests that the trap density, including interface trap and semiconductor bulk trap, can be decreased by the ion insertion of a very thin ITO film into the ITZO/SiO{sub 2} reference device. These results demonstrate that the double active layer TFT can potentially be applied to the flat panel display.

  4. Simulation of semiconductor devices

    International Nuclear Information System (INIS)

    Oriato, D.

    2001-09-01

    In this thesis a drift diffusion model coupled with self-consistent solutions of Poisson's and Schroedinger's equations, is developed and used to investigate the operation of Gunn diodes and GaN-based LEDs. The model also includes parameters derived from Monte Carlo calculations of the simulated devices. In this way the characteristics of a Monte Carlo approach and of a quantum solver are built into a fast and flexible drift-diffusion model that can be used for testing a large number of heterostructure designs in a time-effective way. The full model and its numerical implementation are described in chapter 2. In chapter 3 the theory of Gunn diodes is presented. A basic model of the dynamics of domain formation and domain transport is described with particular regard to accumulation and dipole domains. Several modes of operation of the Gunn device are described, varying from the resonance mode to the quenched mode. Details about transferred electron devices and negative differential resistance in semiconductor materials are given. In chapter 4 results from the simulation of a simple conventional gunn device confirm the importance of the doping condition at the cathode. Accumulation or dipole domains are achieved respectively with high and low doping densities. The limits of a conventional Gunn diode are explained and solved by introducing the heterostructure Gunn diode. This new design consists of a conventional GaAs transit region coupled with an electron launcher at the cathode, made using an AIGaAs heterostructure step. Simulations show the importance of the insertion of a thin highly-doped layer between the transit region and the electron launcher in order to improve device operation. Chapter 5 is an introduction to Ill-nitrides, in particular GaN and its alloy ln-GaN. We outline the discrepancy in the elastic and piezoelectric parameters found in the literature. Strain, dislocations and piezoelectricity are presented as the main features of a InGaN/GaN system

  5. Reactor coolant cleanup device

    International Nuclear Information System (INIS)

    Igarashi, Noboru.

    1986-01-01

    Purpose: To enable to introduce reactor water at high temperature and high pressure as it is, as well as effectively adsorb to eliminate cobalt in reactor water. Constitution: The coolant cleanup device comprises a vessel main body inserted to coolant pipeway circuits in a water cooled reactor power plant and filters contained within the vessel main body. The filters are prepared by coating and baking powder of metal oxides such as manganese ferrite having a function capable of adsorbing cobalt in the coolants onto the surface of supports made of metals or ceramics resistant to strong acids and alkalies in the form of three-dimensional network structure, for example, zircaloy-2, SUS 303 and the zirconia (baking) to form a basic filter elements. The basic filter elements are charged in plurality to the vessel main body. (Kawaiami, Y.)

  6. Reactor shutdown device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu.

    1982-01-01

    Purpose: To obtain a highly reliable reactor shutdown device capable of checking its function irrespective of the state whether shutdown or operation in a gas-cooled type reactor. Constitution: A hopper is disposed above a guide tube inserted into the reactor core and particulate neutron absorbers are contained in the hopper. An opening for falling particles is disposed to the bottom of the hopper in opposition to the upper end of the guide pipe and the opening is closed by a plug suspended by way of a weld line so as to be capable of dropping. A power source for supplying electrical current to the weld line is disposed. Accordingly, if the current is supplied to the weld line, the line is cut by welding to fall the plug so that the neutron-absorbing particles fall from the opening into the guide pipe to shutdown the reactor, whereby high reliability is obtained for the operation. (Seki, T.)

  7. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  8. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  9. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  10. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  11. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  12. Evaluation of low-frequency operational limit of proposed ITER low-field-side reflectometer waveguide run including miter bends

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guiding [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy and Plasma Science and Technology Inst. (PSTI); Peebles, W. A. [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy and Plasma Science and Technology Inst. (PSTI); Doyle, E. J. [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy and Plasma Science and Technology Inst. (PSTI); Crocker, N. A. [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy and Plasma Science and Technology Inst. (PSTI); Wannberg, C. [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy and Plasma Science and Technology Inst. (PSTI); Lau, Cornwall H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hanson, Gregory R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Doane, John L. [General Atomics, San Diego, CA (United States)

    2017-10-19

    The present design concept for the ITER low-field-side reflectometer transmission line (TL) consists of an ~40 m long, 6.35 cm diameter helically corrugated waveguide (WG) together with ten 90° miter bends. This paper presents an evaluation of the TL performance at low frequencies (33-50 GHz) where the predicted HE11 mode ohmic and mode conversion losses start to increase significantly. Quasi-optical techniques were used to form a near Gaussian beam to efficiently couple radiation in this frequency range into the WG. We observed that the output beams from the guide remained linearly polarized with cross-polarization power levels of ~1.5%-3%. The polarization rotation due to the helical corrugations was in the range ~1°-3°. The radiated beam power profiles typically show excellent Gaussian propagation characteristics at distances >20 cm from the final exit aperture. The round trip propagation loss was found to be ~2.5 dB at 50 GHz and ~6.5 dB at 35 GHz, showing an inverse increase with frequency. This was consistent with updated calculations of miter bend and ohmic losses. At low frequencies (33-50 GHz), the mode purity remained very good at the exit of the waveguide, and the losses are perfectly acceptable for operation in ITER. Finally, the primary challenge may come from the future addition of a Gaussian telescope and other filter components within the corrugated guide, which will likely introduce additional perturbations to the beam profile and an increase in mode-conversion loss.

  13. Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy.

    Science.gov (United States)

    Noel, Camille E; Parikh, Parag J; Spencer, Christopher R; Green, Olga L; Hu, Yanle; Mutic, Sasa; Olsen, Jeffrey R

    2015-01-01

    Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.

  14. Methodological developments of low field MRI: Elasto-graphy, MRI-ultrasound interaction and dynamic nuclear polarization

    International Nuclear Information System (INIS)

    Madelin, Guillaume

    2005-01-01

    This thesis deals with two aspects of low field (0.2 T) Magnetic Resonance Imaging (MRI): the research of new contrasts due to the interaction between Nuclear Magnetic Resonance (NMR) and acoustics (elasto-graphy, spin-phonon interaction) and enhancement of the signal-to-noise ratio by Dynamic Nuclear Polarization (DNP). Magnetic Resonance Elasto-graphy (MRE) allows to assess some viscoelastic properties of tissues by visualization of the propagation of low frequency acoustic strain waves. A review on MRE is given, as well as a study on local measurement of the acoustic absorption coefficient. The next part is dedicated to MRI-ultrasound interaction. First, the ultrasonic transducer was calibrated for power and acoustic field using the comparison of two methods: the radiation force method (balance method) and laser interferometry. Then, we tried to modify the T1 contrast of tissues by spin-phonon interaction due to the application of ultrasound at the resonance frequency at 0.2 T, which is about 8.25 MHz. No modification of T1 contrast has been obtained, but the acoustic streaming phenomenon has been observed in liquids. MRI visualization of this streaming could make possible to calibrate transducers as well as to assess some mechanical properties of viscous fluids. The goal of the last part was to set up DNP experiments at 0.2 T in order to enhance the NMR signal. This double resonance method is based on the polarization transfer of unpaired electrons of free radicals to the surrounding protons of water. This transfer occurs by cross relaxation during the saturation of an electronic transition using Electronic Paramagnetic Resonance (EPR). Two EPR cavities operating at 5.43 GHz have been tested on oxo-TEMPO free radicals (nitroxide). An enhancement of the NMR signal by a factor 30 was obtained during these preliminary experiments. (author)

  15. Aspects of 'low field' magnetotransport in epitaxial thin films of the ferromagnetic metallic oxide SrRuO3

    International Nuclear Information System (INIS)

    Moran, O.; Saldarriaga, W.; Baca, E.

    2007-01-01

    Epitaxial thin films of the conductive ferromagnetic oxide SrRuO 3 were grown on an (001) SrTiO 3 (STO) substrate by using DC sputtering technique. The magnetic and magnetoresistive properties of the films were measured by applying the magnetic field both perpendicular (out-of-plane) and parallel (in-plane) to the film plane and ever maintaining the direction of the applied field perpendicular to that of the transport current. The films grown on an (001) STO substrate showed identical magnetization properties in two orthogonal crystallographic directions of the substrate, [100] S and [001] S (in-plane and out-of-plane geometry), which suggests the presence of a multi domain structure within the plane of the film. For such samples, no anisotropic field (hard axis) along de [001]s direction, i.e., perpendicular to the film-plane could be detected. Nevertheless, a distinguishable temperature dependent out-of-plane anisotropic magnetoresistance (MR) along with strong temperature dependent low field hysteretic MR(H) behavior was detected for the studied films. A negative MR ratio MR(T)=[ρ(μ 0 H=9T; T)-ρ( μ 0 H=0T; T)]/ρ( μ 0 H=0T; T) on the order of a few percent, with maximums of ∼6% and ∼4% (right at the Curie temperature, T C ∼160K) was calculated for an in-plane and out-of plane measuring geometry, respectively. In addition there is an equally strong MR effect at low temperatures, which might be related to the temperature dependence of the magnetocrystalline anisotropy together with a magnetization rotation. Both the MR(T) behavior and the achieved values (except for T 3 films grown on 2 o miscut (001) STO substrates with the current parallel to the field and parallel to the [1-bar11] direction, which was identified as the easier axis for magnetization

  16. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  17. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  18. Technical note: Computer-manufactured inserts for prosthetic sockets.

    Science.gov (United States)

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Development of collimator insert for linac based stereotactic irradiation

    International Nuclear Information System (INIS)

    Singh, I.R.R.; Brindha, S.; Ravindran, B.P.; Rajshekhar, V.

    1999-01-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter ( 7 LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7 LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes. (author)

  20. Insertional Polymorphisms of Endogenous Feline Leukemia Viruses

    Science.gov (United States)

    Roca, Alfred L.; Nash, William G.; Menninger, Joan C.; Murphy, William J.; O'Brien, Stephen J.

    2005-01-01

    The number, chromosomal distribution, and insertional polymorphisms of endogenous feline leukemia viruses (enFeLVs) were determined in four domestic cats (Burmese, Egyptian Mau, Persian, and nonbreed) using fluorescent in situ hybridization and radiation hybrid mapping. Twenty-nine distinct enFeLV loci were detected across 12 of the 18 autosomes. Each cat carried enFeLV at only 9 to 16 of the loci, and many loci were heterozygous for presence of the provirus. Thus, an average of 19 autosomal copies of enFeLV were present per cat diploid genome. Only five of the autosomal enFeLV sites were present in all four cats, and at only one autosomal locus, B4q15, was enFeLV present in both homologues of all four cats. A single enFeLV occurred in the X chromosome of the Burmese cat, while three to five enFeLV proviruses occurred in each Y chromosome. The X chromosome and nine autosomal enFeLV loci were telomeric, suggesting that ectopic recombination between nonhomologous subtelomeres may contribute to enFeLV distribution. Since endogenous FeLVs may affect the infectiousness or pathogenicity of exogenous FeLVs, genomic variation in enFeLVs represents a candidate for genetic influences on FeLV leukemogenesis in cats. PMID:15767400

  1. Effects on behaviour and rein tension on horses ridden with or without martingales and rein inserts.

    Science.gov (United States)

    Heleski, C R; McGreevy, P D; Kaiser, L J; Lavagnino, M; Tans, E; Bello, N; Clayton, H M

    2009-07-01

    Unsteady hand position can cause discomfort to the horse, potentially leading to conflict behaviours (CB) such as head tossing or tail lashing. Some instructors feel that martingales or elastic rein inserts can reduce discomfort caused by inexperienced and unsteady hands. Others consider these devices to be inappropriate 'crutches'. Four horses and nine riders were tested under three conditions in random order: plain reins, adjustable training martingales (TM), and elasticised rein inserts (RI). Rein-tension data (7s) and behavioural data (30s) were collected in each direction. Rein-tension data were collected via strain-gauge transducers. Behavioural data were assessed using an ethogram of defined behaviours. No differences in the number of CB were observed. Mean rein tension for TM was higher than that of RI or controls. Relative to the withers, the head was lower for horses ridden with martingales. Carefully fitted martingales may have a place in riding schools that teach novices.

  2. [Utilization of Essure® micro-insert for hydrosalpynx occlusion in infertile women].

    Science.gov (United States)

    Thébault, N; Broux, P-L; Moy, L; Vialard, J

    2012-04-01

    To assess the feasibility and the results on fertility of tubal hysteroscopic proximal occlusion with Essure(®) micro-insert in women with hydrosalpinges. Thirteen infertile women with hydrosalpinges, who underwent hysteroscopic tubal exclusion by Essure(®) prior to IVF procedure. The placement of micro-insert was feasible and easy in every patient, with no intra-operative complication. Only one postoperative infectious complication (pyosalpinx) occurred. We report a 64 % rate of pregnancy, and a 18 % rate of normally ongoing pregnancies with no Essure(®)-related complication. Hydrosalpinges occlusion by Essure(®) device might be an easy and safe alternative to laparoscopic treatment, with successful results on fertility and without adverse effects on pregnancy outcomes. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  3. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  4. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition.

    Science.gov (United States)

    Delvadia, Renish R; Longest, P Worth; Hindle, Michael; Byron, Peter R

    2013-06-01

    Inhaler orientation with respect to a patient's mouth may be an important variable determining the efficiency of aerosol lung delivery. The effect of insertion angle on regional deposition was evaluated for a series of inhalers using concurrent in vitro and computational fluid dynamics (CFD) analysis. Geometrically realistic physical mouth-throat (MT) and upper tracheobronchial (TB) models were constructed to connect different inhalers at a series of insertion angles relative to the horizontal plane of the model. These models were used to assess albuterol sulfate deposition from the Novolizer(®) dry powder inhaler (DPI), Proventil(®) HFA pressurized metered dose inhaler (MDI), and Respimat(®) Soft Mist™ Inhaler (SMI) following the actuation of a single dose. Drug deposition from Novolizer DPI was studied for Salbulin(®) and an experimental "drug only" formulation. Albuterol sulfate was recovered and quantified from the device and the MT and TB regions. Significant differences in MT and total lung dose (TLD) of albuterol sulfate deposition were not observed for Salbulin Novolizer DPI and Respimat SMI inserted at different angles. In contrast, drug-only Novolizer DPI and Proventil HFA MDI showed a significant difference in MT and TLD deposition using different insertion angles. For drug-only Novolizer DPI and Proventil HFA MDI, the lowest and the highest MT depositions were observed at +10° and -20°, respectively; for Respimat SMI and Salbulin Novolizer DPI, these angles were -10° and +10°, and +20° and -20°, respectively. CFD simulations were in agreement with the experimental results and illustrated shifts in local particle deposition associated with changes in insertion angle. The effect of inhaler orientation at the inhaler-mouth interface on MT aerosol deposition appeared to be dependent on velocity, aerosol size, and formulation. These findings not only demonstrate the need for patient education on correct inhaler orientation, but provide important

  5. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  6. Spin effects in high- and low-field magnetotransport experiments in semimagnetic Cd1-xMnxTe heterostructures

    International Nuclear Information System (INIS)

    Betthausen, Christian

    2012-01-01

    Within the framework of this PhD we report on the very first observation of the fractional Quantum Hall Effect (FQHE) in both, a non-magnetic CdTe and a semimagnetic Cd 1-x Mn x Te quantum well device. To our knowledge, this constitutes the first demonstration of this effect in the II-VI material family. Furthermore, our results reveal that the formation of fractional Quantum Hall states is not inhibited by the presence of magnetic impurities in a quantum structure. The second part of this thesis addresses an alternative route to realize efficient spin transistor action. Typically, spin transistor designs relying on spin-orbit interaction principally suffer from low signal levels due to limitations in spin injection efficiency and fast spin decay. Here we present an approach to realize spin transistor action in systems where spin information is protected by propagating it adiabatically. This is achieved by inducing tunable diabatic Landau-Zener transitions that lead to a backscattering of spins and hence allow controlling the transmission of spin-polarized charge carriers through the device, i.e. switching between 'on' and 'off' states. We demonstrate the validity of our approach in a Cd 1-x Mn x Te diluted magnetic semiconductor quantum well structure where efficient spin transport is observed over device distances of 50 μm. In contrast to other spin transistor designs we find that our concept is exceptionally tolerant against disorder.

  7. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  8. Effect of oxide insertion layer on resistance switching properties of copper phthalocyanine

    Science.gov (United States)

    Joshi, Nikhil G.; Pandya, Nirav C.; Joshi, U. S.

    2013-02-01

    Organic memory device showing resistance switching properties is a next-generation of the electrical memory unit. We have investigated the bistable resistance switching in current-voltage (I-V) characteristics of organic diode based on copper phthalocyanine (CuPc) film sandwiched between aluminum (Al) electrodes. Pronounced hysteresis in the I-V curves revealed a resistance switching with on-off ratio of the order of 85%. In order to control the charge injection in the CuPc, nanoscale indium oxide buffer layer was inserted to form Al/CuPc/In2O3/Al device. Analysis of I-V measurements revealed space charge limited switching conduction at the Al/CuPc interface. The traps in the organic layer and charge blocking by oxide insertion layer have been used to explain the absence of resistance switching in the oxide buffer layered memory device cell. Present study offer potential applications for CuPc organic semiconductor in low power non volatile resistive switching memory and logic circuits.

  9. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  10. Is Low-field NMR a Complementary Tool to GC-MS in Quality Control of Essential Oils? A Case Study

    NARCIS (Netherlands)

    Krause, Andre; Wu, Yu; Tian, Runtao; Beek, van Teris A.

    2018-01-01

    High-field NMR is an expensive and important quality control technique. In recent years, cheaper and simpler low-field NMR has become available as a new quality control technique. In this study, 60 MHz 1 H-NMR was compared with GC-MS and refractometry for the detection of adulteration of essential

  11. MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Reinikainen, Heli; Blanco Sequeiros, Andreas M.; Ojala, Risto; Paeaekkoe, Eija; Tervonen, Osmo; Vaara, Teuvo

    2007-01-01

    The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. Seven breast LCNBs and 10 hook wire markings were performed under MR guidance on 11 patients. The diagnosis was confirmed by excision biopsy or mastectomy in 12 lesions and with histopathological and cytological diagnosis and 12-month clinical follow-up in one lesion. All lesions seen in the high-field scanner were also successfully identified and targeted in the low-field scanner. The following procedures were typically technically successful. There were difficulties due to unsatisfactory functioning of some core biopsy guns. Detailed description of low-field MR guidance and optical tracking in breast biopsies is provided. The procedure seems accurate and safe and provides means to obtain a histological diagnosis of a breast lesion only seen with MRI. The low-field biopsy system is comparable to the high-field MRI system. MR-compatible biopsy guns need to be improved. (orig.)

  12. Detection of early osteoarthritis in the centrodistal joints of Icelandic horses: Evaluation of radiography and low-field magnetic resonance imaging.

    Science.gov (United States)

    Ley, C J; Björnsdóttir, S; Ekman, S; Boyde, A; Hansson, K

    2016-01-01

    Validated noninvasive detection methods for early osteoarthritis (OA) are required for OA prevention and early intervention treatment strategies. To evaluate radiography and low-field magnetic resonance imaging (MRI) for the detection of early stage OA osteochondral lesions in equine centrodistal joints using microscopy as the reference standard. Prospective imaging of live horses and imaging and microscopy of cadaver tarsal joints. Centrodistal (distal intertarsal) joints of 38 Icelandic research horses aged 27-29 months were radiographed. Horses were subjected to euthanasia approximately 2 months later and cadaver joints examined with low-field MRI. Osteochondral joint specimens were classified as negative or positive for OA using light microscopy histology or scanning electron microscopy. Radiographs and MRIs were evaluated for osteochondral lesions and results compared with microscopy. Forty-two joints were classified OA positive with microscopy. Associations were detected between microscopic OA and the radiography lesion categories; mineralisation front defect (Pradiography and low-field MRI pooled lesion categories, but radiography was often superior when individual lesion categories were compared. Early stage centrodistal joint OA changes may be detected with radiography and low-field MRI. Detection of mineralisation front defects in radiographs may be a useful screening method for detection of early OA in centrodistal joints of young Icelandic horses. © 2015 EVJ Ltd.

  13. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  14. Enhanced citrate production through gene insertion in Aspergillus niger

    DEFF Research Database (Denmark)

    Jongh, Wian de; Nielsen, Jens

    2007-01-01

    The effect of inserting genes involved in the reductive branch of the tricarboxylic acid (TCA) cycle on citrate production by Aspergillus niger was evaluated. Several different genes were inserted individually and in combination, i.e. malate dehydrogenase (mdh2) from Saccharomyces cerevisiae, two...

  15. Load beam unit replaceable inserts for dry coal extrusion pumps

    Science.gov (United States)

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  16. Forward and reverse genetics: The LORE1 retrotransposon insertion mutants

    DEFF Research Database (Denmark)

    Fukai, Eigo; Malolepszy, Anna; Sandal, Niels Nørgaard

    2014-01-01

    The endogenous Lotus retrotransposon 1 (LORE1) transposes in the germ line of Lotus japonicus plants that carry an active element. This feature of LORE1 has been exploited for generation of a large non-transgenic insertion mutant population, where insertions have been annotated using next-generat...

  17. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  18. Additive Manufacturing for Highly Efficient Window Inserts CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Roschli, Alex C. [ORNL; Chesser, Phillip C. [ORNL; Love, Lonnie J. [ORNL

    2018-04-01

    ORNL partnered with the Mackinac Technology Company to demonstrate how additive manufacturing can be used to create highly energy efficient window inserts for retrofit in pre-existing buildings. Many early iterations of the window inserts were fabricated using carbon fiber reinforced thermoplastics and polycarbonate films as a stand in for the low-e coated films produced by the Mackinac Technology Company. After demonstration of the proof of concept, i.e. custom window inserts with tensioned film, the materials used for the manufacture of the frames was more closely examined. Hollow particle-filled syntactic foam and low-density polymer composites formed by expandable microspheres were explored as the materials used to additively manufacture the frames of the inserts. It was concluded that low-cost retrofit window inserts in custom sizes could be easily fabricated using large scale additive manufacturing. Furthermore, the syntactic and expanded foams developed and tested satisfy the mechanical performance requirements for the application.

  19. Turbine airfoil having near-wall cooling insert

    Science.gov (United States)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  20. Reactor power measuring device

    International Nuclear Information System (INIS)

    Izumi, Mikio; Sano, Yuji; Seki, Eiji; Yoshida, Toshifumi; Ito, Toshiaki.

    1993-01-01

    The present invention provides a self-powered long detector having a sensitivity over the entire length of a reactor core as an entire control rod withdrawal range of a BWR type reactor, and a reactor power measuring device using a gamma ray thermometer which scarcely causes sensitivity degradation. That is, a hollow protection pipe is disposed passing through the reactor core from the outside of a reactor pressure vessel. The self-powered long detectors and the gamma ray thermometers are inserted and installed in the protection pipe. An average reactor power in an axial direction of the reactor relative to a certain position in the horizontal cross section of the reactor core is determined based on the power of the self-powered long detector over the entire length of the reactor core. Since the response of the self-powered detector relative to a local power change is rapid, the output is used as an input signal to a safety protection device of the reactor core. Further, a gamma ray thermometer secured in the reactor and having scarce sensitivity degradation is used instead of an incore travelling neutron monitor used for relative calibration of an existent neutron monitor secured in the reactor. (I.S.)

  1. Ceramic drug-delivery devices.

    Science.gov (United States)

    Lasserre, A; Bajpai, P K

    1998-01-01

    A variety of ceramics and delivery systems have been used to deliver chemicals, biologicals, and drugs at various rates for desired periods of time from different sites of implantation. In vitro and in vivo studies have shown that ceramics can successfully be used as drug-delivery devices. Matrices, inserts, reservoirs, cements, and particles have been used to deliver a large variety of therapeutic agents such as antibiotics, anticancer drugs, anticoagulants, analgesics, growth factors, hormones, steroids, and vaccines. In this article, the advantages and disadvantages of conventional drug-delivery systems and the different approaches used to deliver chemical and biological agents by means of ceramic systems will be reviewed.

  2. Assembly of the PLT device

    International Nuclear Information System (INIS)

    Marino, R.

    1975-11-01

    The assembly of the PLT device began in June 1974 with a preassembly of the mechanical structure at a remote site. The preassembly sequence incorporated final fabrication procedures with an initial staging operation. This successful staging/fabrication procedure proved to be an invaluable asset when the final assembly was started in August 1974. The assembly continued with the initial reassembly of the previously tested structural components at the final machine site. Construction was interrupted at several points to allow for toroidal field coil, vacuum vessel, and poloidal coil installation. Two phases of toroidal field coil power tests were included in the assembly sequence prior to, and just after the vacuum vessel insertion

  3. Development of injection moulded, ultrasonically welded immiscible phase filtration devices

    DEFF Research Database (Denmark)

    Kistrup, Kasper

    for ultrasonic welding, suitable for microfluidic systems. A methodology has been established where energy directors can be quickly added to existing mould inserts, using laser micromachining. The produced device was performance tested by isolating methicillin-resistant Staphylococcus aureus from bovine whole....... The device appliesmagnetic bead-based solid-phase extraction for nucleic acid extraction from biological samples, using the immiscible phase filtration (IPF) approach. Device development has employed injection moulding for part fabrication and ultrasonic welding for bonding. Rapid prototyping...

  4. Process and device for exchanging neutron absorber rods

    International Nuclear Information System (INIS)

    Baero, G.; Kraus, W.; Stindt, W.

    1987-01-01

    The control element repair device contains lifting equipment for inserting the control element in the accommodation device. Due to the case position assigned to each absorber rod of a control element, after removing the carrier with the absorber rods fixed to it, the defective rods can be replaced by new ones. The accommodation device has a support to support the carrier. Turning the control element for the PWR through 180 0 is prevented. (DG) [de

  5. Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings

    Science.gov (United States)

    Patel, Paras R.; Na, Kyounghwan; Zhang, Huanan; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Yoon, Euisik; Chestek, Cynthia A.

    2016-01-01

    Objective Single carbon fiber electrodes (d=8.4 μm) insulated with parylene-c and functionalized with PEDOT:pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion method any increase in the channel count by fabricating carbon fiber arrays would be impractical. In this study, we utilize a water soluble coating and structural backbones that allow us to create, implant, and record from fully functionalized arrays of carbon fibers with ~150 μm pitch. Approach Two approaches were tested for the insertion of carbon fiber arrays. The first method used a PEG coating that temporarily stiffened the fibers while leaving a small portion at the tip exposed. The small exposed portion (500 μm – 1 mm) readily penetrated the brain allowing for an insertion that did not require the handling of each fiber by forceps. The second method involved the fabrication of silicon support structures with individual shanks spaced 150 μm apart. Each shank consisted of a small groove that held an individual carbon fiber. Main results Our results showed that the PEG coating allowed for the chronic implantation of carbon fiber arrays in 5 rats with unit activity detected at 31 days post-implant. The silicon support structures recorded single unit activity in 3 acute rat surgeries. In one of those surgeries a stacked device with 3 layers of silicon support structures and carbon fibers was built and shown to readily insert into the brain with unit activity on select sites. Significance From these studies we have found that carbon fibers spaced at ~150 μm readily insert into the brain. This greatly increases the recording density of chronic neural probes and paves the way for even higher density devices that have a minimal scarring response. PMID:26035638

  6. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  7. Thermonuclear device

    International Nuclear Information System (INIS)

    Matsuyoshi, Hiroshi; Kiuchi, Teruo.

    1981-01-01

    Purpose: To effectively receive the large hoop force acting in a toroidal magnet coil conductor in a limited space by burying an electrical insulator spacer between confronting coil side surfaces. Constitution: Holes are opened at the confronting portions in space between magnet coil conductors each covered with confronting layer electrical insulators, an electrical insulator spacer is so inserted into the holes as to be partly buried, and the entirety is covered with earth insulators and hardened. Thus, the inner space between the coil conductors can be effectively utilized, the spacer plugs the holes, and when the spacer is independently mechanically machined, it can be engaged within the holes of the coil conductors with high accuracy, so that hoop force produced in the coil conductors can be reliably received by utilizing the space between the coil conductors. (Yoshino, Y.)

  8. Investigation of over-moulded hybrid metal/polymer devices

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Tang, Peter Torben

    2006-01-01

    principles, in-process manufacturing technologies, as well as testing methodologies have to be established in order to be able to develop such integrated devices. In this paper an investigation of the bonding between miniaturized metal insert and a polymer matrix is presented. A special demonstrator...... was designed and manufactured by over-moulding and hot-embossing. The bonding strength between the insert and the plastic part was tested by means of a tensile test. A variety of parameters was studied in order to investigate their influence on the bonding: different polymeric and metallic materials, insert...

  9. Measuring device for control rod driving time

    International Nuclear Information System (INIS)

    Tanaka, Kazuhiko; Hanabusa, Masatoshi.

    1993-01-01

    The present invention concerns a measuring device for control driving time having a function capable of measuring a selected control rod driving time and measuring an entire control rod driving time simultaneously. A calculation means and a store means for the selected rod control rod driving time, and a calculation means and a store means for the entire control rod driving time are disposed individually. Each of them measures the driving time and stores the data independent of each other based on a selected control rod insert ion signal and an entire control rod insertion signal. Even if insertion of selected and entire control rods overlaps, each of the control rod driving times can be measured reliably to provide an advantageous effect capable of more accurately conducting safety evaluation for the nuclear reactor based on the result of the measurement. (N.H.)

  10. Effect of low and staggered gap quantum wells inserted in GaAs tunnel junctions

    Science.gov (United States)

    Louarn, K.; Claveau, Y.; Marigo-Lombart, L.; Fontaine, C.; Arnoult, A.; Piquemal, F.; Bounouh, A.; Cavassilas, N.; Almuneau, G.

    2018-04-01

    In this article, we investigate the impact of the insertion of either a type I InGaAs or a type II InGaAs/GaAsSb quantum well on the performances of MBE-grown GaAs tunnel junctions (TJs). The devices are designed and simulated using a quantum transport model based on the non-equilibrium Green’s function formalism and a 6-band k.p Hamiltonian. We experimentally observe significant improvements of the peak tunneling current density on both heterostructures with a 460-fold increase for a moderately doped GaAs TJ when the InGaAs QW is inserted at the junction interface, and a 3-fold improvement on a highly doped GaAs TJ integrating a type II InGaAs/GaAsSb QW. Thus, the simple insertion of staggered band lineup heterostructures enables us to reach a tunneling current well above the kA cm‑2 range, equivalent to the best achieved results for Si-doped GaAs TJs, implying very interesting potential for TJ-based components, such as multi-junction solar cells, vertical cavity surface emitting lasers and tunnel-field effect transistors.

  11. Hysteroscopic Essure Inserts for Permanent Contraception: Extended Follow-Up Results of a Phase III Multicenter International Study.

    Science.gov (United States)

    Chudnoff, Scott G; Nichols, John E; Levie, Mark

    2015-01-01

    To describe safety, tolerability, and effectiveness results through 5 years of follow-up of a Phase III trial with Essure inserts. Multicenter, nonrandomized, single-arm international study (Canadian Task Force classification II-3). Thirteen clinical study centers in the United States, Europe, and Australia. A total of 518 previously fertile women seeking permanent contraception. The objective of the hysteroscopic sterilization procedure was bilateral Essure insert placement (ESS205 model) and tubal occlusion. Women with satisfactory device location and tube occlusion (based on modified hysterosalpingography [HSG]) were instructed to discontinue alternative contraception and to rely on Essure inserts for permanent contraception. The primary endpoint for the Phase III study was the rate of pregnancies occurring during the first year of relying (i.e., HSG-confirmed occlusion) on the Essure inserts for permanent contraception (i.e., 12 months after HSG). For the full 5 years of follow-up (5 years total of relying on the Essure inserts for contraception), the endpoints of interest were safety, prevention of pregnancy, and satisfaction. No pregnancies were reported among women relying on the Essure inserts who completed the full 5 years of follow-up. As of December 5, 2007, 449 women with successful bilateral placement relying on the Essure inserts contributed a total 24 942 woman-months of follow-up for assessing effectiveness. Overall, the Essure inserts were generally well tolerated, with participant comfort rated as "good" to "excellent" by 99% of women (382 of 385) after 5 years of use. Similarly, overall satisfaction was rated as "somewhat" to "very satisfied" by 98% of women (376 of 384) after 5 years of use. The majority of adverse events reported during the 5 years of follow-up were rated as either "mild" or "moderate" in severity. Three severe events (abdominal pain with very heavy periods and irregular menstrual bleeding) were reported in 2 subjects during

  12. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  13. Lithium insertion mechanism in SnS2

    International Nuclear Information System (INIS)

    Lefebvre-Devos, I.; Olivier-Fourcade, J.; Jumas, J.C.; Lavela, P.

    2000-01-01

    We study lithium insertion in SnS 2 by means of 119 Sn Moessbauer spectroscopy, x-ray absorption spectroscopy at Sn L I,III , and S K edges, and theoretical electronic structures (calculated in the density-functional theory framework). An insertion mechanism is derived according to the Li amount. It shows the influence of the SnS 2 -layered structure on the Sn reduction, particularly the possibility of an intermediate oxidation state between Sn IV and Sn II , which is not observed during Li insertion in three-dimensional sulfides

  14. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  15. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  16. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  17. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  18. A novel specialized suture and inserting device for the resuspension of ptotic facial tissues: early results.

    Science.gov (United States)

    Bisaccia, Emil; Kadry, Razan; Saap, Liliana; Rogachefsky, Arlene; Scarborough, Dwight

    2009-04-01

    In the past decade, the popularity of minimally invasive procedures for facial rejuvenation has increased. To describe a new specialized suture, and its associated technique, used to elevate sagging tissues of the face and neck. A detailed description of the technique and the results obtained in 20 patients in whom we have used this novel approach. Attention was given to appropriate patient selection. The primary focus was on the correction of the jowl, jawline, and neck subunits. It involves the percutaneous introduction of a novel 3-0 polypropylene suture that has 10 absorbable hollow cones along its axis that are equally interspersed with knots. Once the absorbable cones are resorbed into the surrounding tissues, the non-absorbable suture component can be removed without compromising the aesthetic outcome. All patients demonstrated improvement in these areas, with minimal complications. One patient required resuspension using the open technique. (Excessive ptotic tissue was later excised for an optimal cosmetic result.) The suture and technique described in this article provide a major contribution to the correction of ptosis of facial tissues. When done in conjunction with other procedures, such as neck and jowl microliposuction, this technique has proven to be a useful addition to facial rejuvenation.

  19. Projects of SR sources including research and development for insertion devices in the USSR

    International Nuclear Information System (INIS)

    Kulipanov, G.

    1990-01-01

    Some technical information on the electron and positron storage rings - SR sources that are being constructed, used or developed at the Novosibirsk Institute of Nuclear Physics (INP), is given. The parameters and construction of wigglers and undulators (electromagnetic, superconducting, and based on permanent magnets) that are intended to be used at such storage rings are described. Various schemes of installation of wigglers, undulators and FEL at storage rings is considered. The ways of minimizing the influence of their magnetic fields on particle motion in storage rings are treated. (author)

  20. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  1. The effect of divalent ions on the elasticity and pore collapse of chalk evaluated from compressional wave velocity and low-field Nuclear Magnetic Resonance (NMR)

    DEFF Research Database (Denmark)

    Katika, Konstantina; Addassi, Mouadh; Alam, Mohammad Monzurul

    2015-01-01

    The effects of divalent ions on the elasticity and the pore collapse of chalk were studied through rock-mechanical testing and low-field Nuclear Magnetic Resonance (NMR) measurements. Chalk samples saturated with deionized water and brines containing sodium, magnesium, calcium and sulfate ions were...... subjected to petrophysical experiments, rock mechanical testing and low-field NMR spectroscopy. Petrophysical characterization involving ultrasonic elastic wave velocities in unconfined conditions, porosity and permeability measurements, specific surface and carbonate content determination and backscatter...... electron microscopy of the materials were conducted prior to the experiments. The iso-frame model was used to predict the bulk moduli in dry and saturated conditions from the compressional modulus of water-saturated rocks. The effective stress coefficient, as introduced by Biot, was also determined from...

  2. Evaluation of poly(vinylpyrrolidone) and collagen by Low Field Nuclear Magnetic Resonance Spectroscopy; Avaliacao da polivinilpirrolidona e do colageno por ressonancia magnetica nuclear de baixo campo

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paula de M.; Tavares, Maria I.B. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Macromoleculas Professora Eloisa Mano]. E-mail: pmcosta@ima.ufrj.br

    2005-07-01

    Blends of natural and synthetic polymers represent a new class of materials with better mechanical properties and biocompatibility than those of the single components. Collagen and poly(vinylpyrrolidone) are well known for their important biological properties. The blending of collagen with poly(vinylpyrrolidone) makes it possible to obtain new materials in which strong interactions between the synthetic and biological components occur. Do to the excellent biocompatibility of these polymers, this blend has been much studied intending biomedical applications. And a one technique that can provide important information on molecular mobility, compatibility and even evaluate the interactions that can occur with these polymers is the Low Field Nuclear Magnetic Resonance Spectroscopy. Thus, the purpose of this work is to evaluate collagen and poly(vinylpyrrolidone) by Low Field Nuclear Magnetic Resonance Spectroscopy. From the values of relaxation times obtained, we can conclude that these materials have different interactions, and different mobility domains, confirming the heterogeneity and complexity of these materials. (author)

  3. Orientation-dependent low field magnetic anomalies and room-temperature spintronic material – Mn doped ZnO films by aerosol spray pyrolysis

    CSIR Research Space (South Africa)

    Nkosi, SS

    2013-12-01

    Full Text Available of ferromagnetism, a relatively new phenomenon called “low-field microwave absorption” has been observed in ferromagnetic materials and other various materials such as high temperature superconductors, ferrites, manganites, doped silicate glasses and soft... absorption phenomenon has been observed in ferromagnetic materials and various other materials such as superconductors, ferrites, manganites, semiconductors, doped silicate glasses, in soft materials and recently in iron monosilicides films [41- 46...

  4. Net-bottom Cage Inserts for Water Bird Casualties

    Directory of Open Access Journals (Sweden)

    Jackie Belle

    2017-10-01

    Full Text Available My Bright Idea is a net-bottomed cage insert, which is used to support pelagic avian casualties. The idea was designed and modified by the International Bird Rescue in California (Bird Rescue.

  5. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    International Nuclear Information System (INIS)

    Shen, C J; Ramkumar, A; Lal, A; Gilmour, R F Jr

    2011-01-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval

  6. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted tape inserts with air as the working fluid.

  7. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan; Zhang, Wenxing; Wan, Wenhui; Cui, Yi; Wang, Enge

    2010-01-01

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a

  8. Fireplace insert and its parameters depend on the used glazing

    Science.gov (United States)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  9. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao; Falivene, Laura; Boffa, Giusi; Sá nchez, Sheila Ortega; Caporaso, Lucia; Grassi, Alfonso; Mecking, Stefan

    2016-01-01

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively

  10. Zero insertion force socket for photoactivation patient treatment system

    International Nuclear Information System (INIS)

    Troutner, V.H.

    1988-01-01

    Automatic operating zero insertion force socket for use in a photoactivatable reagent treatment system wherein photoactivatable agents, in contact with patient blood cells, are irradiated extracorporeally and then returned to the patient

  11. Fuel exchange device for FBR type reactor

    International Nuclear Information System (INIS)

    Onuki, Koji.

    1993-01-01

    The device of the present invention can provide fresh fuels with a rotational angle aligned with the direction in the reactor core, so that the fresh fuels can be inserted being aligned with apertures of the reactor core even if a self orientation mechanism should fail to operate. That is, a rotational angle detection means (1) detects the rotational angle of fresh fuels before insertion to the reactor core. A fuel rotational angle control means (2) controls the rotational angle of the fresh fuels by comparing the detection result of the means (1) and the data for the insertion position of the reactor core. A fuel rotation means (3) compensates the rotational angel of the fresh fuels based on the control signal from the means (2). In this way, when the fresh fuels are inserted to the reactor core, the fresh fuels set at the same angle as that for the aperture of the reactor core. Accordingly, even if the self orientation mechanism should not operate, the fresh fuels can be inserted smoothly. As a result, it is possible to save loss time upon fuel exchange and mitigate operator's burden during operation. (I.S.)

  12. Outcomes in the ultrasound follow-up of the Essure micro-insert: complications and proper placement.

    Science.gov (United States)

    Thiel, John; Suchet, Ian; Tyson, Nerissa; Price, Pamela

    2011-02-01

    To review the use of three-dimensional ultrasound follow-up of the Essure micro-insert placement at three months for the identification of misplaced coils and complications. We conducted a retrospective cohort study of reproductive age women requesting permanent sterilization in a tertiary care ambulatory women's clinic. Women who underwent placement of the Essure micro-insert were assessed for appropriate positioning of the Essure micro-insert coil using three-dimensional ultrasound as well as hysterosalpingography when indicated. A total of 610 women who had undergone the Essure procedure with ultrasound follow-up at three months were retrospectively reviewed and in 524 (86%) the location and shape were both normal. The remaining 86 (15%) required hysterosalpingography to confirm proper placement, 34 because of a non-diagnostic ultrasound and the remaining 52 for a complication noted on ultrasound, including perforation, proximal or distal migration of the device, or device expulsion. Ultrasound can be used at three months after Essure placement to identify normal placement as well as misplaced and perforated devices.

  13. Validation of a low field Rheo-NMR instrument and application to shear-induced migration of suspended non-colloidal particles in Couette flow

    Science.gov (United States)

    Colbourne, A. A.; Blythe, T. W.; Barua, R.; Lovett, S.; Mitchell, J.; Sederman, A. J.; Gladden, L. F.

    2018-01-01

    Nuclear magnetic resonance rheology (Rheo-NMR) is a valuable tool for studying the transport of suspended non-colloidal particles, important in many commercial processes. The Rheo-NMR imaging technique directly and quantitatively measures fluid displacement as a function of radial position. However, the high field magnets typically used in these experiments are unsuitable for the industrial environment and significantly hinder the measurement of shear stress. We introduce a low field Rheo-NMR instrument (1 H resonance frequency of 10.7MHz), which is portable and suitable as a process monitoring tool. This system is applied to the measurement of steady-state velocity profiles of a Newtonian carrier fluid suspending neutrally-buoyant non-colloidal particles at a range of concentrations. The large particle size (diameter > 200 μm) in the system studied requires a wide-gap Couette geometry and the local rheology was expected to be controlled by shear-induced particle migration. The low-field results are validated against high field Rheo-NMR measurements of consistent samples at matched shear rates. Additionally, it is demonstrated that existing models for particle migration fail to adequately describe the solid volume fractions measured in these systems, highlighting the need for improvement. The low field implementation of Rheo-NMR is complementary to shear stress rheology, such that the two techniques could be combined in a single instrument.

  14. Blind bedside insertion of small bowel feeding tubes.

    LENUS (Irish Health Repository)

    Duggan, SN

    2009-12-01

    The use of Naso-Jejunal (NJ) feeding is limited by difficulty in feeding tube placement. Patients have traditionally required transfer to Endoscopy or Radiology for insertion of small bowel feeding tubes, with clear resource implications. We hypothesised that the adoption of a simple bedside procedure would be effective and reduce cost. Clinical nutrition and nurse specialist personnel were trained in the 10\\/10\\/10 method of blind bedside NJ insertion.

  15. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  16. Enhancement of device performance of organic solar cells by an interfacial perylene derivative layer

    KAUST Repository

    Kim, Inho; Haverinen, Hanna M.; Li, Jian; Jabbour, Ghassan E.

    2010-01-01

    We report that device performance of organic solar cells consisting of zinc phthalocyanine and fullerene (C60) can be enhanced by insertion of a perylene derivative interfacial layer between fullerene and bathocuproine (BCP) exciton blocking layer

  17. The Intra-uterine Device in Soweto and Other Townships | Spilhaus ...

    African Journals Online (AJOL)

    South African Medical Journal ... all the tribes found in South Africa, though Zulus and Sothos predominate, The variation of ... The performance of the intra-uterine device (IUD) is discussed against a background of well over 25000 insertions, ...

  18. Cleaning device for fuel assemblies

    International Nuclear Information System (INIS)

    Kita, Kaoru.

    1986-01-01

    Purpose: To completely remove obstacles deposited to the lower sides of supporting lattices for fuel assemblies by utilizing water within a pit before reloading of the fuel assemblies. Constitution: A cylindrical can, to which a fuel assembly is inserted through the upper end opening thereof, is vertically disposed within water of a pit and the bottom of the can is communicated with a pump by way of a suction pipe and a filter device disposed out of the pit. While on the other hand, a fuel assembly is suspended downwardly by a crane and inserted to the inside of the can through the upper end of the opening thereof and supported therein followed by starting the pump. As a result, water in the pit is circulated through the inside of the can, suction pipe, filtering device, pump, discharge pipe and to the inside of the pit thereby enabling to completely eliminate obstacles deposited to the lower surface, etc. of supporting lattices for the fuel assembly supported within the can. (Takahashi, M.)

  19. Report on converging insert moulding with µ-IM

    DEFF Research Database (Denmark)

    Islam, Aminul

    moulding with µ-IM  Task 5.2.1 and COTECH demonstrator: guide line for 5PRC production based on the concept of Task 5.2.1 Information and results provided by this deliverable will be directly used for one of the COTECH demonstrators production which will call for convergent insert moulding with µ......Task 5.2.1 deals with the technical feasibility of converging the state-of-the-art µ IM process with insert moulding to offer a wide range of multi-material µ components. The main objective of this deliverable is to summarize state-of-the-art information and to make the guideline needed...... for the convergence. In particular the following aspects are summed up in the deliverable:  Need for converging insert moulding with µ-IM  Objectives and expected outcome from task 5.2.1  State-of-the-art micro insert moulding and different scenario of micro insert moulding  Challenges ahead of converging insert...

  20. Evaluation of a high resolution silicon PET insert module

    Energy Technology Data Exchange (ETDEWEB)

    Grkovski, Milan, E-mail: milan.grkovski@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brzezinski, Karol [IFIC/CSIC, Valencia (Spain); Cindro, Vladimir [Jožef Stefan Institute, Ljubljana (Slovenia); Clinthorne, Neal H. [University of Michigan, Ann Arbor, MI (United States); Kagan, Harris [Ohio State University, Columbus, OH (United States); Lacasta, Carlos [IFIC/CSIC, Valencia (Spain); Mikuž, Marko [Jožef Stefan Institute, Ljubljana (Slovenia); Solaz, Carles [IFIC/CSIC, Valencia (Spain); Studen, Andrej [Jožef Stefan Institute, Ljubljana (Slovenia); Weilhammer, Peter [Ohio State University, Columbus, OH (United States); Žontar, Dejan [Jožef Stefan Institute, Ljubljana (Slovenia)

    2015-07-11

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm{sup 2} pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2–4.8 mm) filled with {sup 18}F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm)

  1. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  2. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  3. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  4. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  5. Latching device

    Science.gov (United States)

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  6. High thermal stability in W/MgO/CoFeB/W/CoFeB/W stacks via ultrathin W insertion with perpendicular magnetic anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yi; Yu, Tao [School of Physics and Nuclear Energy Engineering, Beihang University, Beijing 100191 (China); Zhu, Zhengyong; Zhong, Huicai [Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029 (China); Khamis, Khamis Masoud [School of Physics and Nuclear Energy Engineering, Beihang University, Beijing 100191 (China); Zhu, Kaigui, E-mail: kgzhu@buaa.edu.cn [School of Physics and Nuclear Energy Engineering, Beihang University, Beijing 100191 (China); Key Laboratory of Micro-Nano Measurement-Manipulation and Physics, Ministry of Education, Beihang University, Beijing 100191 (China)

    2016-07-15

    The perpendicular magnetic anisotropy (PMA) of a series of top MgO/CoFeB/W stacks were studied. In these stacks, the thickness of CoFeB is limited in a range of 1.1–2.2 nm. It was found that the stack can still maintain PMA in a 1.9 nm thick CoFeB free layer. Besides, we investigated the thermal stability factor ∆ of a spin transfer torque magnetic random access memory (STT-MRAM) by inserting an ultra-thin W film of 0.8 nm between two CoFeB films. The result shows a clear PMA behavior for the samples with CoFeB thickness up to 2.5 nm, and an in-plane magnetic anisotropy (IMA) when the CoFeB is thicker than 2.5 nm. Moreover, the thermal stability factor ∆ of the CoFeB stack with W insertion is about 132 for a 50 nm size STT-MRAM device, which is remarkably improved compared to 112 for a sample without W insertion. Our results represent an alternative way to realize the endurance at high annealing temperature, high-density and high ∆ in STT-MRAM device by ultra-thin W insertion. - Highlights: • The MgO/CoFeB/W multilayer can still maintain PMA in a CoFeB thickness of 1.9 nm. • The sample with 2.5 nm thickness of CoFeB by W insertion can still maintain PMA. • The sample with W insertion can still maintain PMA until the annealing temperature as high as 350 °C. • The thermal stability factor ∆ of sample with W insertion could be increase to about 132 for a 50 nm size STT-MRAM device.

  7. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    Science.gov (United States)

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-27

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  8. Sampling device for radioactive molten salt

    International Nuclear Information System (INIS)

    Shindo, Masato

    1998-01-01

    The present invention provides a device for accurately sampling molten salts to which various kinds of metals in a molten salt storage tank are mixed for analyzing them during a spent fuel dry type reprocessing. Namely, the device comprises a sampling tube having an opened lower end to be inserted into the radioactive molten salts stored in a tank and keeps reduced pressure from the upper end, and a pressure reducing pipeline having one end connected to the sampling tube and other end connected to an evacuating pump. In this device, the top end of the sampling tube is inserted to a position for sampling the radioactive molten salts (molten salts). The pressure inside the evacuating pipeline connected to the upper portion of the sampling tube is reduced for a while. In this case, the inside of the pressure reducing pipeline is previously evacuated by the evacuating pump so as to keep a predetermined pressure. Since the pressure in the sampling tube is lowered, molten salts are inserted into the sampling tube, the sampling tube is withdrawn, and the molten salts flown in the sampling tube are analyzed. (I.S.)

  9. Unilateral versus bilateral stent insertion for malignant hilar biliary obstruction.

    Science.gov (United States)

    Chang, Gang; Xia, Feng-Fei; Li, Hong-Fu; Niu, Su; Xu, Yuan-Shun

    2017-11-01

    To determine the clinical efficiency and long-term outcomes between unilateral and bilateral stent insertion in patients with malignant hilar biliary obstruction. From August 2012 to February 2016, 63 consecutive patients with malignant hilar biliary obstruction were treated with unilateral or bilateral stent insertion at our center. The bilateral stents were inserted using the side-by-side technique. The clinical efficiency and long-term outcomes were compared between the two groups. Unilateral and bilateral stent insertions were successfully performed in 31 of 33 and 27 of 30 patients, respectively (P = 0.912). No procedure-related complication occurred. Clinical success was achieved in 29 of 31 patients in the unilateral stent group and in 26 of 27 patients in the bilateral stent group (P = 0.637). During the follow-up, re-obstruction of stent occurred in five patients in the unilateral stent group and in three patients in the bilateral stent group (P = 0.58). The significant differences were not observed in the stent patency time (368 vs. 387 days, P = 0.685) and survival (200 vs. 198 days, P = 0.751) between two groups. Based on the univariate and multivariate analyses, the independent risk factors for decreasing the survival time included higher Eastern Cooperative Oncology Group performance status (P = 0.018), higher alanine aminotransferase level (P = 0.009), and absence of anticancer treatment after stent insertion (P = 0.002). Compared to bilateral stent insertion for malignant hilar biliary obstruction, unilateral stent insertion can provide comparable clinical efficiency and long-term outcomes.

  10. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Energy Technology Data Exchange (ETDEWEB)

    Bergner, Jennifer B. [Harvard University Department of Chemistry and Chemical Biology, 10 Oxford Street, Cambridge, MA 02138 (United States); Öberg, Karin I.; Rajappan, Mahesh [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-08-10

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  11. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Science.gov (United States)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  12. Radioactive source manipulator and stowage device

    International Nuclear Information System (INIS)

    Burton, C.

    1980-01-01

    A description is given of a radioactive source manipulator and stowage device comprising: a cylindrical body; a transversely disposed socket formed near one end of said cylindrical body for receiving a radioactive source; a cylindrical sleeve rotatably mounted on said cylindrical body; and an aperture formed in the wall of said sleeve whereby rotation of said sleeve to axially align said aperture with said socket will permit a radioactive source to be inserted into and removed from said socket and rotation of said sleeve to move said aperture out of alignment with said socket when the socket contains a radioactive source readies the device for manipulation and stowage

  13. Micro-Fluidic Device for Drug Delivery

    Science.gov (United States)

    Beebe, David J. (Inventor); MacDonald, Michael J. (Inventor); Eddington, David T. (Inventor); Mensing, Glennys A. (Inventor)

    2014-01-01

    A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

  14. Laser working device

    International Nuclear Information System (INIS)

    Shibanuma, Kiyoshi; Kakudate, Satoshi; Oka, Kiyoshi; Terakado, Takuya; Kondo, Mitsunori; Munakata, Tadashi; Makino, Yoshinobu; Honda, Keizo.

    1995-01-01

    A transmission pipe transmits laser beams along an axis thereof, and is inserted at the top end to a pipeline to be fabricated. A flat mirror is secured to the top end of the transmission pipe, and laser beams are reflected by the mirror, passed through a fabrication nozzle and focused to a fabrication point in the pipeline to be fabricated. A lens-type light focusing system is guided to the fabrication point by a plurality of rollers rotatable in the axial direction disposed in circumferential direction each at an equal pitch at the outer circumference of the transmission pipe. A centering mechanism is disposed for keeping the transmission pipe coaxially with the pipeline to be fabricated. Further, there are also disposed a mirror-type light focusing optical system for focusing light by a paraboloidal mirror and a spherical vehicle rotatable in all directions. A laser fabrication device can be reduced in the size, and it can be used in a high temperature and highly radioactive circumstance. (N.H.)

  15. Damping device

    International Nuclear Information System (INIS)

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  17. Strainer device

    International Nuclear Information System (INIS)

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  18. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  19. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  20. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  1. Analysis of generic insertions made of two symmetric triplets

    CERN Document Server

    D'Amico, T E

    1998-01-01

    This paper reports on the study undertaken to explore the capabilities of a symmetric triplet to achieve the optics constraints required by the inner triplet of an insertion and more generally of a co mplete insertion made of two symmetric triplets to match a double focus to a FODO lattice. It is based on analytical treatment formulating a number of constraints equal to the parameters available. Th is thorough and systematic analysis made it possible to establish for an inner triplet as well as for a complete insertion the existence of solutions and to explicitly find out all the solutions, with out resorting to unguided numerical searches. As a by-product, a lattice transformer, made of a single triplet, that matches two different FODO cells has been singled out and studied in details. The r esults should be profitable in a number of cases. Here, the method is applied to an insertion of the type of an experimental LHC insertion in order to investigate its domain of validity and tunability .

  2. Sorting genomes by reciprocal translocations, insertions, and deletions.

    Science.gov (United States)

    Qi, Xingqin; Li, Guojun; Li, Shuguang; Xu, Ying

    2010-01-01

    The problem of sorting by reciprocal translocations (abbreviated as SBT) arises from the field of comparative genomics, which is to find a shortest sequence of reciprocal translocations that transforms one genome Pi into another genome Gamma, with the restriction that Pi and Gamma contain the same genes. SBT has been proved to be polynomial-time solvable, and several polynomial algorithms have been developed. In this paper, we show how to extend Bergeron's SBT algorithm to include insertions and deletions, allowing to compare genomes containing different genes. In particular, if the gene set of Pi is a subset (or superset, respectively) of the gene set of Gamma, we present an approximation algorithm for transforming Pi into Gamma by reciprocal translocations and deletions (insertions, respectively), providing a sorting sequence with length at most OPT + 2, where OPT is the minimum number of translocations and deletions (insertions, respectively) needed to transform Pi into Gamma; if Pi and Gamma have different genes but not containing each other, we give a heuristic to transform Pi into Gamma by a shortest sequence of reciprocal translocations, insertions, and deletions, with bounds for the length of the sorting sequence it outputs. At a conceptual level, there is some similarity between our algorithm and the algorithm developed by El Mabrouk which is used to sort two chromosomes with different gene contents by reversals, insertions, and deletions.

  3. Insertion compounds of transition-metal and uranium oxides

    International Nuclear Information System (INIS)

    Chippindale, A.M.; Dickens, P.G.; Powell, A.V.

    1991-01-01

    Several transition-metal and actinide oxides, in which the metal occurs in a high oxidation state, have open covalent structures and are capable of incorporating alkali and other electropositive metals under mild conditions to form insertion compounds A x MO n . These are solids which have several features in common: Over a range of compositions, A x MO n exists as one or more stable or metastable phases in which the structure of the parent oxide MO n is largely retained and the insertion element A is accommodated interstitially. Insertion is accompanied by a redox process A=A i . + e - M in which M is reduced and the electronic properties of the parent oxide change to those typical of a mixed-valence compound. The insertion process xA + MO n = A x MO n can be reversed, at least to some extent, by chemical or electrochemical reaction, with retention of structure (topotactic reaction). This review concentrates on methods of synthesis, characterisation, crystal structure and thermochemistry of these insertion compounds. It updates and extends previous work. (author)

  4. Seamless lesion insertion in digital mammography: methodology and reader study

    Science.gov (United States)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  5. Guide tube insert assembly for use in a nuclear reactor

    International Nuclear Information System (INIS)

    Hopkins, R.J.; Land, J.T.

    1992-01-01

    This patent describes an internals assembly for a nuclear reactor of the type including an upper support plate and an upper core plate, each having apertures for conducting control rod assemblies into an out of fuel assemblies with the apertures of the upper support plate being aligned with the apertures of the upper core plate, a guide tube insert assembly comprising: an elongated tubular body extending between at least one of the aligned apertures formed in the upper support plate and the upper core plate; guide plates within the elongated tubular body, each of the guide plates having a planar surface extending substantially perpendicular to an axial direction of the tubular body; at least one interconnecting means for interconnecting the guide plates into a guide tube insert assembly such that the guide plates are simultaneously mountable within and removable from the elongated body, and the periphery of each of the guide plates is spaced apart from the inner walls of the elongated tubular body at every point when the insert assembly is mounted within the tubular body, and a stabilizing means for securing the lowermost guide plate of the guide tube insert assembly within the elongated tubular body to prevent rotational and lateral movement between the guide tube insert assembly and the tubular body

  6. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  7. Thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  8. Thermonuclear device

    International Nuclear Information System (INIS)

    Kuriyama, Masaaki; Yamamoto, Masahiro; Furuyama, Masayuki; Saito, Ryusei.

    1981-01-01

    Purpose: To enable the efficient and rapid cooling of a vacuum vessel by cooling with gas when the temperature of the vacuum vessel is higher than the boiling point of water and cooling with water when the temperature is lower than the boiling point of water. Constitution: A cooling pipe is provided through an insulating pipe on the outer periphery of a vacuum vessel. The cooling pipe communicates through a cooling gas valve and a coolant valve with a cooling gas supply device and a coolant supply device, and a heat exchanger is disposed at the pipe. When the vessel is higher than the boiling point of the coolant the coolant valve is closed and the cooling gas valve is opened and gas is supplied to cool the vessel. The gas is recoverd through a heat exchanger. On the other hand, when the temperature of vessel is lower than the boiling point of the coolant, the gas valve is closed, the coolant valve is opened, and the vessel is cooled with coolant. The vacuum vessel can be cooled for short time employing both the gas and the coolant together. (Yoshino, Y.)

  9. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  10. Remote vacuum or pressure sealing device and method for critical isolated systems

    Science.gov (United States)

    Brock, James David [Newport News, VA; Keith, Christopher D [Newport News, VA

    2012-07-10

    A remote vacuum or pressure sealing apparatus and method for making a radiation tolerant, remotely prepared seal that maintains a vacuum or pressure tight seal throughout a wide temperature range. The remote sealing apparatus includes a fixed threaded sealing surface on an isolated system, a gasket, and an insert consisting of a plug with a protruding sample holder. An insert coupling device, provided for inserting samples within the isolated system, includes a threaded fastener for cooperating with the fixed threaded sealing surface on the isolated system. The insert coupling device includes a locating pin for azimuthal orientation, coupling pins, a tooted coaxial socket wrench, and an insert coupling actuator for actuating the coupling pins. The remote aspect of the sealing apparatus maintains the isolation of the system from the user's environment, safely preserving the user and the system from detrimental effect from each respectively.

  11. A device for transferring, in particular, small particles

    International Nuclear Information System (INIS)

    1974-01-01

    The invention relates to a transfer device, in particular for transferring small particles, comprising a helical channel made in the tube inner surface, a device for causing the tube to rotate about its longitudinal axis, a rotating joint adapted to close one of the tube extremities, a device for inserting a substance in the form of granules or of fluid particles into said tube through said joint, and a device for collecting and discharging said substance at the tube opposite end. This can applied to the transfer of small spherical particles e.g. of fuel [fr

  12. Multimodality imaging of the Essure tubal occlusion device.

    Science.gov (United States)

    Simpson, W L; Beitia, L

    2012-12-01

    The Essure device is a permanent birth-control device, which is gaining popularity. The micro-inserts are composed of metallic elements that can be seen on radiography, computed tomography, ultrasound, and magnetic resonance imaging. Knowledge of the normal location and appearance of the Essure device will ensure appropriate patient care. The purpose of this review is to describe the Essure tubal occlusion device and illustrate its normal and abnormal appearance using various imaging methods. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Outcomes of single- vs double-cuff artificial urinary sphincter insertion in low- and high-risk profile male patients with severe stress urinary incontinence.

    Science.gov (United States)

    Ahyai, Sascha A; Ludwig, Tim A; Dahlem, Roland; Soave, Armin; Rosenbaum, Clemens; Chun, Felix K-H; Fisch, Margit; Schmid, Marianne; Kluth, Luis A

    2016-10-01

    To evaluate continence and complication rates of bulbar single-cuff (SC) and distal bulbar double-cuff (DC) insertion in male patients with severe stress urinary incontinence (SUI) according to whether the men were considered low or high risk for unfavourable artificial urinary sphincter (AUS) outcomes. In all, 180 male patients who underwent AUS implantation between 2009 and 2013 were followed according to institutional standards. Patients with previous pelvic radiation therapy, open bulbar urethral or UI surgery ('high risk') underwent distal bulbar DC (123 patients) insertion, all others ('low risk') had proximal bulbar SC (57) insertion. Primary and secondary endpoints consisted of continence and complication rates. Kaplan-Meier analysis determined explantation-free survival, and Cox regression models assessed risk factors for persistent UI and explantation. The median follow-up was 24 months. Whereas there was no significant difference in pad usage/objective continence after SC vs DC insertion, superior rates of subjective/social continence and less persistent UI were reported by the patients with DC devices (all P ≤ 0.02). Overall, device explantation (erosion, infection or mechanical failure) occurred in 12.8% of patients. While early ( 0.05), DC patients had a 5.7-fold higher risk of device explantation during late follow-up (P = 0.02) and significantly shorter explantation-free survival (log-rank, P = 0.003). Distal bulbar DC insertion in patients with a 'high-risk' profile (previous pelvic radiation, urethral surgery) leads to similar objective continence, but higher explantation rates when compared with patients considered 'low risk' with proximal bulbar SCs. Randomised controlled trials comparing both devices will be needed to determine whether the higher explanations rates are attributable to the DC device or to underlying risk factors. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  14. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  15. Giant magnetoresistance on low field in non-stoichiometric La2/3Ca1/3Mn1-xO3

    International Nuclear Information System (INIS)

    Zhao Lifeng; Chen Wei; Shang Jingling; Chen Lei; Liu Sheng; Xia Zhengcai; Yuan Songliu

    2005-01-01

    Electrical transport and low field magnetoresistance (MR) are reported in the La 2/3 Ca 1/3 Mn 1-x O 3 (x = 0-0.16) samples, which are prepared by the sol-gel method followed by a sintering treatment at 1100 0 C. Experimental results show, for x = 0.06, an MR platform is observed in a temperature ∼200 K under the magnetic field of 0.5 T. With an increase in x, the MR effect gets augmented. For the sample with x = 0.16, its MR peak is as high as 50%

  16. Low-field magnetic resonance imaging or combined ultrasonography and anti-cyclic citrullinated peptide antibody improve correct classification of individuals as established rheumatoid arthritis

    DEFF Research Database (Denmark)

    Pedersen, Jens K; Lorenzen, Tove; Ejbjerg, Bo

    2014-01-01

    (RA). METHODS: In 53 individuals from a population-based, cross-sectional study, historic fulfilment of the American College of Rheumatology (ACR) 1987 criteria ("classification") or RA diagnosed by a rheumatologist ("diagnosis") were used as standard references. The sensitivity, specificity and Area....../specificity) was 78% (62%/94%) (classification) and 85% (69%/100%) (diagnosis), while for the total synovitis score of MCP joints plus wrist (cut-off ≥10) it was 78% (62%/94%) (both classification and diagnosis). CONCLUSIONS: Compared with the ACR 1987 criteria, low-field MRI alone or adapted criteria incorporating...

  17. Analysis of plastic deformation in cortical bone after insertion of coated and non-coated self-tapping orthopaedic screws.

    Science.gov (United States)

    Koistinen, A P; Korhonen, H; Kiviranta, I; Kröger, H; Lappalainen, R

    2011-07-01

    Insertion of internal fracture fixation devices, such as screws, mechanically weakens the bone. Diamond-like carbon has outstanding tribology properties which may decrease the amount of damage in tissue. The purpose of this study was to investigate methods for quantification of cortical bone damage after orthopaedic bone screw insertion and to evaluate the effect of surface modification on tissue damage. In total, 48 stainless steel screws were inserted into cadaver bones. Half of the screws were coated with a smooth amorphous diamond coating. Geometrical data of the bones was determined by peripheral quantitative computed tomography. Thin sections of the bone samples were prepared after screw insertion, and histomorphometric evaluation of damage was performed on images obtained using light microscopy. Micro-computed tomography and scanning electron microscopy were also used to examine tissue damage. A positive correlation was found between tissue damage and the geometric properties of the bone. The age of the cadaver significantly affected the bone mineral density, as well as the damage perimeter and diameter of the screw hole. However, the expected positive effect of surface modification was probably obscured by large variations in the results and, thus, statistically significant differences were not found in this study. This can be explained by natural variability in bone tissue, which also made automated image analysis difficult.

  18. The strategic use of inserts in the Brazilian presidential elections

    Directory of Open Access Journals (Sweden)

    Felipe Borba

    2012-01-01

    Full Text Available The aim of this article is to analyze the communication strategies of presidential candidates during the elections held in 2006 and 2010. The focus is on the strategic component of electoral inserts and the methodology consists of investigating how candidates choose to distribute these inserts in the programming of television networks. The results indicate that the candidates pursue different strategies influenced basically by three variables: electoral legislation, their standing in polls and the difference of resources available. In parallel, the article debates the role of the regulation of electoral advertising and how this set of rules influences the level of information of campaigns, the occurrence of attacks, and party strategies. Overall, 2,993 electoral inserts were examined.

  19. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  20. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  1. Insertion of liquid crystal molecules into hydrocarbon monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Piotr, E-mail: ppopov@kent.edu; Mann, Elizabeth K. [Department of Physics, Kent State University, Kent, Ohio 44242 (United States); Lacks, Daniel J. [Department of Chemical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Jákli, Antal [Liquid Crystal Institute, Kent State University, Kent, Ohio 44242-0001 (United States)

    2014-08-07

    Atomistic molecular dynamics simulations were carried out to investigate the molecular mechanisms of vertical surface alignment of liquid crystals. We study the insertion of nCB (4-Cyano-4{sup ′}-n-biphenyl) molecules with n = 0,…,6 into a bent-core liquid crystal monolayer that was recently found to provide good vertical alignment for liquid crystals. The results suggest a complex-free energy landscape for the liquid crystal within the layer. The preferred insertion direction of the nCB molecules (core or tail first) varies with n, which can be explained by entropic considerations. The role of the dipole moments was found to be negligible. As vertical alignment is the leading form of present day liquid crystal displays (LCD), these results will help guide improvement of the LCD technology, as well as lend insight into the more general problem of insertion of biological and other molecules into lipid and surfactant layers.

  2. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  3. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  4. Mammographic and Ultrasonographic Findings of the Chemoport Insertion Site

    International Nuclear Information System (INIS)

    Kim, Seun Jung; Kang, Bong Joo; Cha, Eun Suk; Park, Hye Jung; Kim, Sung Hun; Choi, Jae Jeong; Lee, Ji Hye

    2010-01-01

    To describe mammographic and ultrasonographic findings of previous chemoport insertion sites. We included patients who had abnormal findings at chemoport insertion sites on mammography and ultrasonography from 224 patients who underwent chemoport insertion and breast imaging at our institution between January, 2005, and December, 2007. Abnormal findings were identified in 16 mammographies and 14 ultrasonographies in 10 patients. The mean age was 50.9 years and the age range was from 44 to 67 years. Abnormal findings on mammography and ultrasonography were retrospectively analyzed according to ACR/BI-RADS. All cases were followed up with imaging studies for 2 years to confirm changes after chemoport insertion. Of the abnormal findings identified on mammography, focal asymmetry (7/16) was the most common. Other abnormal findings included mass (6/16), skin retraction (2/16), residual chemoport tip (1/16), and trabecular thickening (1/16). Of the abnormal findings seen on ultrasonography, skin thickening (12/14) was the most common. Other abnormal findings included mass (5/14), diffuse increased echogenicity of subcutaneous tissue (1/14), and a localized skin nodule (1/14). Abnormal findings on mammography and ultrasonography were located in the upper outer quadrant in 5 patients, upper inner quadrant in 3 patients, and mid upper portion in 1 patient. In 1 patient, the abnormal finding was only identified in the mediolateral oblique view of her mammography. Radiologists should be aware of potential abnormal findings on mammography and ultrasonography following chemoport insertion. In particular, ultrasonography is a very useful modality for detecting skin complications after chemoport insertion

  5. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  6. Thermonuclear device

    International Nuclear Information System (INIS)

    Furuyama, Masayuki.

    1979-01-01

    Purpose: To provide the subject device wherein a conductive short-circuiting ring is installed in the vicinity of the bonded part of bellows and thick portion of vacuum vessel in the small circumferential direction of torus, thereby to reduce the electromagnetic force generated at the bellows. Constitution: A conductive short-circuiting ring is provided in the vicinity of the connected part of a thick portion and bellows portion. By this organization, a saddle type current generated at the thick portion by a vertical magnetic field flows through the short-circuiting ring because the resistance at a part where the short-circuiting ring is provided is reduced, and the current flowing through the bellows is remarkably reduced. For this reason, the electromagnetic force generated at the bellows is reduced thereby to prevent the bellows from being destroyed by the electromagnetic force. (Yoshihara, H.)

  7. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  8. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei

    1988-01-01

    Purpose: To obtain high voltage withstanding current introduction terminals not suffering from the effects of the reduction in the creeping voltage withstanding property by the application of magnetic fields. Constitution: This invention concerns a current introduction terminal for supplying electric current to coils for use in a thermonuclear device, etc. The conductor of the current introduction terminal on the side of vacuum is completely covered with solid insulator. This can eliminate the portion of securing the creeping withstanding voltage. The voltage withstanding characteristics of the solid insulator covering the portion of the conductor on the side of vacuum has a constant value irrespective of the atmosphere or the absence or presence of magnetic fields. Accordingly, the voltage withstanding characteristics of the current introduction terminal on the side of vacuum are determined by the property of the solid insulator, which is not reduced by the application of magnetic fields. (Ikeda, J.)

  9. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube

    Directory of Open Access Journals (Sweden)

    Narjis AL Saif

    2015-01-01

    Full Text Available Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  10. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  11. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao

    2016-10-14

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively in-chain anhydride groups are formed by terpolymerization with carbic anhydride. Combined experimental and theoretical DFT studies reveal the key for this direct approach to telechelics to be a match of the comonomers’ different electronics and bulk. Identified essential features of the comonomer are that it is an electron-rich olefin that forms an insertion product stabilized by an additional interaction, namely a π–η3 interaction for the case of VF.

  12. Using PATIMDB to create bacterial transposon insertion mutant libraries.

    Science.gov (United States)

    Urbach, Jonathan M; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M

    2009-04-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software.

  13. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  14. Enhanced optical and electrical properties of Ni inserted ITO/Ni/AZO tri-layer structure for photoelectric applications

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, M. Melvin David; Kim, Hyunki [Department of Electrical Engineering, Incheon National University, Incheon 406772 (Korea, Republic of); Park, Yun Chang [Measurement and Analysis Division, National Nanofab Center (NNFC), Daejeon 305-806 (Korea, Republic of); Kim, Joondong, E-mail: joonkim@incheon.ac.kr [Department of Electrical Engineering, Incheon National University, Incheon 406772 (Korea, Republic of)

    2015-05-15

    Highlights: • Ni-embedding transparent conductor effectively reduces the resistivity. • Ni insertion improves the carrier mobility and collection efficiencies. • ITO/Ni/AZO is effective to improve photo-responses compared to ITO/AZO. - Abstract: A thin Ni layer of 5 nm thickness was deposited in between indium-tin-oxide (ITO) and aluminum-doped-zinc oxide (AZO) layers of 50 nm thickness each. The Ni inserting tri-layer structure (ITO/Ni/AZO) showed lower resistivity of 5.51 × 10{sup −4} Ωcm which is nearly 20 times lesser than 97.9 × 10{sup −4} Ωcm of bilayer structure (ITO/AZO). A thin Ni layer in between ITO and AZO enhanced the carrier concentration, mobility and photoresponse behaviors so that figure of merit (FOM) value of ITO/Ni/AZO device was greater than that of ITO/AZO device. ITO/Ni/AZO structure showed improved quantum efficiencies over a broad range of wavelengths (∼350–950 nm) compared to that of ITO/AZO bilayer structure, resulting in enhanced photoresponses. These results show that the optical, electrical and photoresponse properties of ITO/AZO structure could be enhanced by inserting Ni layer of 5 nm thickness in between ITO and AZO layers.

  15. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  16. Comparative evaluation of chest radiography, low-field MRI, the Shwachman-Kulczycki score and pulmonary function tests in patients with cystic fibrosis

    International Nuclear Information System (INIS)

    Anjorin, Angela; Vogl, Thomas J.; Schmidt, Helga; Posselt, Hans-Georg; Smaczny, Christina; Ackermann, Hanns; Deimling, Michael; Abolmaali, Nasreddin

    2008-01-01

    The aim of this study was to investigate whether the parenchymal lung damage in patients suffering from cystic fibrosis (CF) can be equivalently quantified by the Chrispin-Norman (CN) scores determined with low-field magnetic resonance imaging (MRI) and conventional chest radiography (CXR). Both scores were correlated with pulmonary function tests (PFT) and the Shwachman-Kulczycki method (SKM). To evaluate the comparability of MRI and CXR for different states of the disease, all scores were applied to patients divided into three age groups. Seventy-three CF patients (mean SKM score: 62 ± 8) with a median age (range) of 14 years (7-32) were included. The mean CN scores determined with both imaging methods were comparable (CXR: 12.1 ± 4.7; MRI: 12.0 ± 4.5) and showed high correlation (P < 0.05, R = 0.97). Only weak correlations were found between imaging, PFT, and SKM. Both imaging modalities revealed significantly more severe disease expression with age, while PFT and SKM failed to detect early signs of disease. We conclude that imaging of the lung in CF patients is capable of detecting subtle and early parenchymal destruction before lung function or clinical scoring is affected. Furthermore, low-field MRI revealed high consistency with chest radiography and may be used for a thorough follow-up while avoiding radiation exposure. (orig.)

  17. Dependence on film thickness of grain boundary low-field magnetoresistance in thin films of La0.7Ca0.3MnO3

    International Nuclear Information System (INIS)

    Todd, N. K.; Mathur, N. D.; Blamire, M. G.

    2001-01-01

    The magnetoresistance of grain boundaries in the perovskite manganites is being studied, both in polycrystalline materials, and thin films grown on bicrystal substrates, because of interest in low-field applications. In this article we show that epitaxial films grown on SrTiO 3 bicrystal substrates of 45 degree misorientation show magnetoresistance behavior which is strongly dependent on the thickness of the film. Thin films, e.g., 40 nm, can show a large low-field magnetoresistance at low temperatures, with very sharp switching between distinct high and low resistance states for fields applied in plane and parallel to the boundary. Thicker films show a more complex behavior of resistance as a function of field, and the dependence on the angle between the applied field and the grain boundary is altered. These changes in magnetoresistance behavior are linked to the variation in morphology of the films. Thin films are coherently strained, due to the mismatch with the substrate, and very smooth. Thicker films relax, with the formation of defects, and hence different micromagnetic behavior. [copyright] 2001 American Institute of Physics

  18. Optimizing performance of plasmonic devices for photonic circuits

    DEFF Research Database (Denmark)

    Rosenzveig, Tiberiu; Hermannsson, Pétur Gordon; Boltasseva, Alexandra

    2010-01-01

    specifications similar to or better than commercially available thermo-optic integrated optical components. Specifically, we have considered the insertion loss, power consumption, footprint, polarization-dependent loss, extinction ratio, and frequency response of the plasmonic devices, in addition to fabrication...

  19. Experience with UIDC insertion outside of menses in Kenya ...

    African Journals Online (AJOL)

    %) or insertion outside of menses (6.9%), than the within menses (4.3%) groups. However, the differences were not statistically significant. Adjusted odds ratios for IUCD outside of menses and oligomenorrhoea/amenorrhea groups were 1.65 ...

  20. Prototype ISR Superconducting Quadrupole for the low beta insertion.

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The four coils are provisionally kept together by aluminium clamps while epoxy-glass bands are wrapped around them to form a number of spacer rings.Stainless steel spacers were then inserted between these rings and the yoke quadrants. The persons are Michel Bouvier(left) and Pierre Pugin. See also7702690X.