WorldWideScience

Sample records for low-dose 60-kev neutron

  1. A Kinematically Beamed, Low Energy Pulsed Neutron Source for Active Interrogation

    International Nuclear Information System (INIS)

    Dietrich, D.; Hagmann, C.; Kerr, P.; Nakae, L.; Rowland, M.; Snyderman, N.; Stoeffl, W.; Hamm, R.

    2004-01-01

    We are developing a new active interrogation system based on a kinematically focused low energy neutron beam. The key idea is that one of the defining characteristics of SNM (Special Nuclear Materials) is the ability for low energy or thermal neutrons to induce fission. Thus by using low energy neutrons for the interrogation source we can accomplish three goals, (1) Energy discrimination allows us to measure the prompt fast fission neutrons produced while the interrogation beam is on; (2) Neutrons with an energy of approximately 60 to 100 keV do not fission 238U and Thorium, but penetrate bulk material nearly as far as high energy neutrons do and (3) below about 100keV neutrons lose their energy by kinematical collisions rather than via the nuclear (n,2n) or (n,n') processes thus further simplifying the prompt neutron induced background. 60 keV neutrons create a low radiation dose and readily thermal capture in normal materials, thus providing a clean spectroscopic signature of the intervening materials. The kinematically beamed source also eliminates the need for heavy backward and sideway neutron shielding. We have designed and built a very compact pulsed neutron source, based on an RFQ proton accelerator and a lithium target. We are developing fast neutron detectors that are nearly insensitive to the ever-present thermal neutron and neutron capture induced gamma ray background. The detection of only a few high energy fission neutrons in time correlation with the linac pulse will be a clear indication of the presence of SNM

  2. Oncogenic transformation in C3H10T1/2 cells by low-energy neutrons.

    Science.gov (United States)

    Miller, R C; Marino, S A; Napoli, J; Shah, H; Hall, E J; Geard, C R; Brenner, D J

    2000-03-01

    Occupational exposure to neutrons typically includes significant doses of low-energy neutrons, with energies below 100 keV. In addition, the normal-tissue dose from boron neutron capture therapy will largely be from low-energy neutrons. Microdosimetric theory predicts decreasing biological effectiveness for neutrons with energies below about 350 keV compared with that for higher-energy neutrons; based on such considerations, and limited biological data, the current radiation weighting factor (quality factor) for neutrons with energies from 10 keV to 100 keV is less than that for higher-energy neutrons. By contrast, some reports have suggested that the biological effectiveness of low-energy neutrons is similar to that of fast neutrons. The purpose of the current work is to assess the relative biological effectiveness of low-energy neutrons for an endpoint of relevance to carcinogenesis: in vitro oncogenic transformation. Oncogenic transformation induction frequencies were determined for C3H10T1/2 cells exposed to two low-energy neutron beams, respectively, with dose-averaged energies of 40 and 70 keV, and the results were compared with those for higher-energy neutrons and X-rays. These results for oncogenic transformation provide evidence for a significant decrease in biological effectiveness for 40 keV neutrons compared with 350 keV neutrons. The 70 keV neutrons were intermediate in effectiveness between the 70 and 350 keV beams. A decrease in biological effectiveness for low-energy neutrons is in agreement with most (but not all) earlier biological studies, as well as microdosimetric considerations. The results for oncogenic transformation were consistent with the currently recommended decreased values for low-energy neutron radiation weighting factors compared with fast neutrons.

  3. DOSIMETRIC response of a REM-500 in low energy neutron fields typical of nuclear power plants.

    Science.gov (United States)

    Aslam; Matysiak, W; Atanackovic, J; Waker, A J

    2012-06-01

    This study investigates the response of a REM-500 to assess neutron quality factor and dose equivalent in low energy neutron fields, which are commonly encountered in the workplace environment of nuclear power stations. The McMaster University 3 MV Van de Graaff accelerator facility was used to measure the response of the instrument in monoenergetic neutron fields in the energy range 51 to 727 keV by bombarding a thin LiF target with 1.93-2.50 MeV protons. The energy distribution of the neutron fields produced in the facility was measured by a (3)He filled gas ionization chamber. The MCA mode of the REM-500 instrument was used to collect lineal energy distributions at varying neutron energies and to calculate the frequency and dose-mean lineal energies. The effective quality factor, Q-, was also calculated using the values of Q(y)listed in the REM-500 operation manual and compared with those of ICRP 60. The authors observed a continuously increasing trend in y - F, y-D, and Q-with an increase in neutron energy. It is interesting to note that standard tissue equivalent proportional counters (TEPCs) filled with tissue equivalent(TE) gas give rise to a similar trend for these microdosimetric quantities of interest in the same energy range; however, the averages calculated in this study are larger by about 15%compared to a TEPC filled with propane-based TE gas probably because of the larger stopping power of protons in propane compared to TE gas. These somewhat larger event sizes did not result in any significant increase in the Q-compared to those obtained from a TEPC filled with TE gas and were found to be in good agreement with other measurements reported earlier at corresponding neutron energies. The instrument quality factor response, R(Q), defined as the ratio of measured quality factor to the calculated quality factor in an ICRU tissue sphere,was found to vary with neutron energy. The instrument response,R(Q), was ~0.6 at 727 keV, which deteriorates further to

  4. The impact of ICRP 60 recommendations on the dose equivalent in low- and high energy neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Jakes, J; Schraube, H [GSF-Forschungszentrum Neuberg, D-85758 Oberschleissheim (Germany). Inst. fuer Strahlenschutz

    1996-12-31

    The objectives of this study was to determine the impact of the increased risk factors for neutrons after ICRP 60 on the operational dose equivalent quantities at a few neutron fields selected with the respect to cover the broad variety of neutron spectra: (1) Cadarache calibration assembly, with average neutron energy around 0.6 MeV, designed to simulate realistic neutron spectra at workplaces. This assembly is basically composed of an almost spherical {sup 238}U converter irradiated by 14.6 MeV neutrons from an accelerator target, placed at its center, and a scattering chamber consisting of a cylindrical polyethylene duct and a series of additional shieldings; (2) Neutron spectra at exposed workplaces in nuclear power plants; (3) Moderated spectra of {sup 252}Cf fission source; (4) Neutron spectra behind a shielding made of the iron (the average energy 5.,89 MeV) and concrete (the average energy 46.51 MeV), respectively; (5) Cosmic rays induced neutron spectra measured on the top of the Zugspitze (2968 m) where there is the average neutron energy around 40 MeV. From the derived neutron spectra, the mean quality factors and conversion factors h after ICRP 21 and ICRP 60, respectively, were calculated. The dose equivalent conversion factors were taken for the region below 20 MeV, and the energy region above 20 MeV. The results show that the operational quantities were affected predominately in the low energy fields, where the changes are given by a factor of 1,3 for the neutron fields given above. As has been expected, the impact of the new recommendations depends on the shape of the neutron spectra. Therefore, this factor can be much higher in the fields where the intermediate energy region is dominant, which is the case of moderated and scattered spectra at some places in the nuclear power plant and around containers with the spent fuel elements. (J.K.) 9 refs.

  5. Development of a TPC for energy and fluence references in low energies neutronic fields (from 8 keV to 5 MeV)

    International Nuclear Information System (INIS)

    Maire, Donovan

    2015-01-01

    In order to judge the measurement reliability, metrology requires to measure quantities with their uncertainties, in relation to a reference through a documented and unbroken chain of calibrations. In neutron radiation field, instrument response has to be known as a function of the neutron energy. Then detector calibrations are required using reference neutron fields. In France, primary reference neutron fields are held by the LNE-IRSN, at the Laboratory for Neutron Metrology and Dosimetry (LMDN). In order to improve reference neutron field characterization, the LNE-IRSN MIMAC μTPC has been developed. This detector is a Time Projection Chamber (TPC), using a gas at low pressure (30 mbar abs. to 1 bar abs.). Nuclear recoils are generated by neutron elastic scattering onto gas atoms. By measuring the nuclear recoil energy and scattering angle, the μTPC detector is able to measure the energy distribution of the neutron fluence between 8 keV and 5 MeV. The main challenge was to perform accurate spectrometry of neutron fields in the keV range, following a primary procedure. First of all, a metrological approach was followed in order to master every physical process taking part in the neutron detection. This approach led to develop the direct and inverse models, representing the detector response function and its inverse function respectively. Using this detailed characterization, the energy distribution of the neutron fluence has been measured for a continuous neutron field of 27 keV. The reconstructed energy is 28,2 ± 4,5 keV, the difference between μTPC integral fluence measurement and other measurement methods is less than 6%. The LNE-IRSN MIMAC μTPC system becomes the only one system able to measure simultaneously energy and fluence at energies lower than 100 keV, following a primary procedure. The project goal is then reached. These measurements at energies lower than 100 keV shows also a non-linearity between the ionization charge and the ion kinetic energy

  6. Dose Evaluation of Neutron within Containment Building of a CE type Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Wook; Han, Jae Mun; Kim, Kyung Doek; Yun, Cheol Whan; Suh, Jang Soo; Kim, Young Jae [Nuclear Environment Technology Institute, Daejeon (Korea, Republic of)

    2005-03-15

    From measured results of the neutron fields at some principal places within the containment building in a CE type nuclear power plant in operation, the radiation exposure of a worker to the neutron at there was evaluated and the equivalent dose reflecting new recommendation (ICRP 60) was compared with that doing the old one (ICRP 26). The measured neutron field was also compared with calibration neutron field. From the analysis, the following conclusion was obtained: the average neutron radiation weighting factor according to new recommendation is 2.41 to 2.71 times higher than the old one. The average neutron radiation weighting factor at the measured place was similar to that at calibration neutron field. The average neutron energy at measured place was between 42 and 158 keV and higher than that of calibration field of 500 keV. So, the measured equivalent dose in nuclear power plant could be overestimated compared to the real equivalent dose.

  7. Neutron transmission and capture measurements and analysis of 60Ni from 1 to 450 keV

    International Nuclear Information System (INIS)

    Perey, C.M.; Harvey, J.A.; Macklin, R.L.; Winters, R.R.; Perey, F.G.

    1982-11-01

    High-resolution transmission and capture measurements of 60 Ni-enriched targets have been made at the Oak Ridge Electron Linear Accelerator (ORELA) from a few eV to 1800 keV in transmission and from 2.5 keV to 5 MeV in capture . The transmission data from 1 to 450 keV were analyzed with a multi-level R-matrix code which uses the Bayes' theorem for the fitting process. This code provides the energies and neutron widths of the resonances inside the 1- to 450-keV region as well as a possible parameterization for outside resonances to describe the smooth cross section in this region. The capture data were analyzed with a least-squares fitting code using the Breit-Wigner formula. From 2.5 to 450 keV, 166 resonances were seen in both sets of data. Correspondence between the energy scales shows a discontinuity around 300 keV which makes the matching of resonances at higher energies difficult. Eighty-nine resonances were seen in the capture data only. Average parameters for the 30 observed s-wave resonances were deduced. The average level spacing D 0 was found to be equal to 15.2 +- 1.5 keV, the strength function, S 0 , equal to (2.2 +- 0.6) x 10 -4 and the average radiation width, GAMMA/sub γ/, equal to 1.30 +- 0.07 eV. The staircase plot of the reduced level widths and the plot of the Lorentz-weighted strength function averaged over various energy intervals show possible evidence for doorway states. The level densities calculated with the Fermi-gas model for l = 0 and for l > 0 resonances were compared with the cumulative number of observed resonances, but the analysis is not conclusive. The average capture cross section as a function of the neutron incident energy is compared to the tail of the giant electric dipole resonance prediction

  8. Dose intercomparison for 400–500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters

    DEFF Research Database (Denmark)

    Gupta, B. L.; Nilekani, S. R.; Gehringer, P.

    1986-01-01

    This paper describes the dose and the depth dose measurements with FWT-60 film and glutamine (Spectrophotometric readout) dosimeters for 400–500 keV electrons. The glutamine powder was spread uniformly in polyethylene bags and the powder thickness in each bag was 5 mg cm−2. Both techniques show...

  9. Presence of neutrons in the low-level background environment estimated by the analysis of the 595.8 keV gamma peak

    Energy Technology Data Exchange (ETDEWEB)

    Anđelić, Brankica; Knežević, David; Jovančević, Nikola; Krmar, Miodrag; Petrović, Jovana; Toth, Arpad; Medić, Žarko; Hansman, Jan

    2017-04-21

    In order to explore possible improvements of the existing techniques developed to estimate the neutron fluence in low-background Ge-spectroscopy systems, gamma spectra were collected by a HPGe detector in the presence of the {sup 252}Cf spontaneous fission neutron source. The spectra were taken with and without a Cd envelope on the detector dipstick, with different thicknesses of plastic used to slow down neutrons. We have analyzed the complex 595.8 keV gamma peak, as well as several more gamma peaks following the neutron interactions in the detector itself and surroundings materials. The investigation shows that some changes of the initial neutron spectra can be monitored by the analysis of the 595.8 keV gamma peak. We have found good agreement in the intensity changes between the long-tail component of the 595.8 keV and the 691 keV gamma peak ({sup 72}Ge(n,n′){sup 72}Ge reaction), usually used for the estimation of the fast neutron fluence. Results also suggest that the thermal neutrons can have a stronger influence on creation of the Gaussian-like part of 595.8 keV peak, than on the 139 keV one following {sup 74}Ge(n,γ){sup 75m}Ge reaction and used in the standard methods (Škoro et al., 1992) [8] for determination of the thermal neutron flux.

  10. The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent

    International Nuclear Information System (INIS)

    Eisen, Y.

    1986-01-01

    The performance of Rossi-type spherical tissue-equivalent chambers with equivalent diameters between 0.5 μm and 2 μm was tested experimentally using monoenergetic and polyenergetic neutron sources in the energy region of 10 keV to 14.5 MeV. In agreement with theoretical predictions both chambers failed to provide LET information at low neutron energies. A dose equivalent algorithm was derived that utilises the event distribution but does not attempt to correlate event size with LET. The algorithm was predicted theoretically and confirmed by experiment. The algorithm that was developed determines the neutron dose equivalent, from the data of the 0.5 μm chamber, to better than +-20% over the energy range of 30 keV to 14.5 MeV. The same algorithm also determines the dose equivalent from the data of the 2 μm chamber to better than +-20% over the energy range of 60 keV to 14.5 MeV. The efficiency of the chambers is 33 counts per μSv, or equivalently about 10 counts s -1 per mSv.h -1 . This efficiency enables the measurement of dose equivalent rates above 1 mSv.h -1 for an integration period of 3 s. Integrated dose equivalents can be measured as low as 1 μSv. (author)

  11. Low doses of neutrons induce changes in gene expression

    International Nuclear Information System (INIS)

    Woloschak, G.E.; Chang-Liu, C.M.; Panozzo, J.; Libertin, C.R.

    1993-01-01

    Studies were designed to identify genes induced following low-dose neutron but not following γ-ray exposure in fibroblasts. Our past work had shown differences in the expression of β-protein kinase C and c-fos genes, both being induced following γ-ray but not neutron exposure. We have identified two genes that are induced following neutron, but not γ-ray, exposure: Rp-8 (a gene induced by apoptosis) and the long terminal repeat (LTR) of the human immunodeficiency (HIV). Rp-8 mRNA induction was demonstrated in Syrian hamster embryo fibroblasts and was found to be induced in cells exposed to neutrons administered at low (0.5 cGy/min) and at high dose rate (12 cGy/min). The induction of transcription from the LTR of HIV was demonstrated in HeLa cells bearing a transfected construct of the chloramphenicol acetyl transferase (CAT) gene driven by the HIV-LTR promoter. Measures of CAT activity and CAT transcripts following irradiation demonstrated an unresponsiveness to γ rays over a broad range of doses. Twofold induction of the HIV-LTR was detected following neutron exposure (48 cGy) administered at low (0.5 cGy/min) but not high (12 cGy/min) dose rates. Ultraviolet-mediated HIV-LTR induction was inhibited by low-dose-rate neutron exposure

  12. Genetic injury in hybrid male mice exposed to low doses of 60CO γ-rays or fission neutrons. 1

    International Nuclear Information System (INIS)

    Grahn, D.; Carnes, B.A.; Farrington, B.H.; Lee, C.H.

    1984-01-01

    Young adult male B6CF 1 mice were exposed to single whole body doses of fission neutrons or 60 Co γ rays. Postspermatogonial dominant lethal injury, incidence of reciprocal chromosome translocations induced in spermatogonia, incidence of abnormal epididymal sperm 4-6 weeks after exposure, and testis weight loss 3-6 weeks after exposure were all measured. Significant effects were seen at 1 and 2.5 rad of neutrons consistent with extrapolation from higher doses, with the exception of dominant lethal mutations, which occurred in significant excess of expectation. Dose-response functions were linear or linear-quadratic, depending upon end point, radiation quality, and dose range. For translocation frequencies, the D 2 term was negative for neutron and positive for γ-ray irradiations. RBE values varied with dose and end point. For testis weight loss and abnormal sperm over the full dose range, the RBEs were between 5 and 6. They were between 7 and 9 at lower doses (< 10 rad) for translocations. RBEs for postimplantation and total dominant lethal rates were 5-6 above 10 rad and 10-14 below 10 rad. The RBEs for preimplant losses were between 15 and 25 above 10 rad and possibly higher below 10 rad, although the data are statistically 'noisy'. (Auth.)

  13. Determination of S- and P-strength functions using fast neutrons - having energy from 30 -360 keV; Odredjivanje S- i P-funkcije 'jacine veze' brzim neutronima - energija od 60 - 360 keV

    Energy Technology Data Exchange (ETDEWEB)

    Boreli, F M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1958-07-01

    Reaction Li{sup 7}(p,n)Be{sup 7} was used as a neutron source to determine the strength functions on a number of intermediate and heavy nuclei at average neutron energies from 60 - 360 keV. The strength functions were obtained by measuring the deviation from exponential attenuation of neutrons passing through the sample. Values obtained at lower energies showed dependence on the atomic weight predicted by the optical model and were in agreement with previous measurements. For the elements in the region A=90 the fast increase of strength function obtained by assuming only S-wave interactions suggests that P-wave interactions are taking place.

  14. Evaluation of neutron response of criticality accident alarm system detector to quasi-monoenergetic 24 keV neutrons

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Yashima, Hiroshi

    2016-01-01

    The criticality accident alarm system (CAAS), which was recently developed and installed at the Japan Atomic Energy Agency's Tokai Reprocessing Plant, consists of a plastic scintillator combined with a cadmium-lined polyethylene moderator and thereby responds to both neutrons and gamma rays. To evaluate the neutron absorbed dose rate response of the CAAS detector, a 24 keV quasi-monoenergetic neutron irradiation experiment was performed at the B-1 facility of the Kyoto University Research Reactor. The detector's evaluated neutron response was confirmed to agree reasonably well with prior computer-predicted responses. (author)

  15. Inelastic scattering of 275 keV neutrons by silver

    International Nuclear Information System (INIS)

    Litvinsky, L.L.; Zhigalov, Ya.A.; Krivenko, V.G.; Purtov, O.A.; Sabbagh, S.

    1997-01-01

    Neutron total, elastic and inelastic scattering cross-scattering of Ag at the E n = 275 KeV neutron energy were measured by using the filtered neutron beam of the WWR-M reactor in Kiev. The d-neutron strength function S n2 of Ag was determined from the analysis of all available data in the E n ≤ keV energy region on neutron inelastic scattering cross-sections with excitation of the first isomeric levels I π m = 7/2 + , E m ∼ 90 keV of 107,109 Ag: S n2 = (1.03 ± 0.19) · 10 -4 . (author). 10 refs, 3 figs

  16. Dose-effect relationships for fife shortening, tumorigenesis, and systemic injuries in mice irradiated with fission neutron or 60Co gamma radiation

    International Nuclear Information System (INIS)

    Ainsworth, E.J.; Fry, R.J.M.; Williamson, F.S.; Brennan, P.C.; Stearner, S.P.; Yang, V.V.; Crouse, D.A.; Rust, J.H.; Borak, T.B.

    1977-01-01

    The objective of this research is to provide additional data on life shortening, neoplastic and non-neoplastic diseases, and other systematic injuries necessary for the determination of dose-response relationships. The data are used to test existing predictive models and formulate new models which may assist with radiation risk assessment. Late somatic effects of fission neutrons from the JANUS reactor or from cobalt-60 gamma radiation are evaluated in young adult B6CF 1 mice that receive either a range of single doses or protracted doses at low dose rates; the protracted irradiation is administered over a 6-month period. After single doses of gamma radiation the relationship between radiation dose and percent life shortening appears linear whereas after single doses of fission spectrum neutrons a non-linear dose response is observed. These results suggest that estimates of radiation risk for fission spectrum neutrons should take into account the following: the curvilinearity of the neutron dose-response curve for life shortening, and the increased life shortening produced by neutron dose fractionation

  17. 6LiF sandwich type detectors for low dose individual monitoring in mixed neutron-photon fields

    International Nuclear Information System (INIS)

    Olko, P.; Budzanowski, M.; Bilski, P.; Burgkhardt, B.; Piesch, E.

    1994-01-01

    ICRP Publication 60 recommends the reduction of the annual dose limit for occupational exposure from 50 to 20 mSv and a doubling of the quality factor for medium energy neutrons. If occupational doses are evaluated every month (which is obligatory e.g. in Germany and in Poland), the individual neutron dosemeter will have to measure neutron doses in the range of 100 μSv. No commercially available, automatic individual dosimetry monitoring system exists that fulfils this requirement. Some of the parameters which influence the evaluation of the neutron dose from readings of TL dosemeters have been studied in order to decrease the variance of the measured neutron signal. In mixed neutron-photon fields, clear separation of the neutron component from the total reading depends also on the uncertainty of the gamma dose measurements. While the thermal albedo neutrons are absorbed mostly at the surface of the 6 LiF detector, the reduction of the detector thickness results in a decrease of its photon sensitivity, while its neutron sensitivity is almost principally maintained. As a consequence, the uncertainty of gamma dose contributes with lower weight to the variance of the evaluated neutron signal. First tests of an optimised 200 μm thick sandwich detector and 0.9 mm thick standard LiF chips were made at low neutron and photon dose ranges using different readers, in order to determine the uncertainty versus dose for different neutron-photon combinations. The conditions under which the new sandwich type detectors may improve albedo neutron dosimetry are demonstrated. (Author)

  18. Transportable, Low-Dose Active Fast-Neutron Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mihalczo, John T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wright, Michael C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McConchie, Seth M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Archer, Daniel E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Palles, Blake A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    This document contains a description of the method of transportable, low-dose active fast-neutron imaging as developed by ORNL. The discussion begins with the technique and instrumentation and continues with the image reconstruction and analysis. The analysis discussion includes an example of how a gap smaller than the neutron production spot size and detector size can be detected and characterized depending upon the measurement time.

  19. Neutron fluence and energy reconstruction with the IRSN recoil detector μ-TPC at 27 keV, 144 keV and 565 keV

    Energy Technology Data Exchange (ETDEWEB)

    Maire, D.; Lebreton, L.; Richer, J.P. [IRSN, PRP-HOM, SDE, LMDN, 13115 Saint Paul-Lez-Durance (France); Bosson, G.; Bourrion, O.; Guillaudin, O.; Riffard, Q.; Santos, D. [CNRS/IN2P3-UJF-INPG, LPSC, 38000 Grenoble (France)

    2015-07-01

    The French Institute for Radioprotection and Nuclear Safety (IRSN), associated to the French Metrology Institute (LNE), is developing a time projection chamber using a Micromegas anode: μ-TPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize with a primary procedure the energy distribution of neutron fluence in the energy range 8 keV - 1 MeV. The time projection chambers are gaseous detectors, which are able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulated detector response. The μ-TPC is a new reliable detector which enables to measure energy distribution of the neutron fluence without deconvolution or neutron calibration contrary to usual gaseous counters. The μ-TPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27.2 keV, 144 keV and 565 keV are shown and compared to the complete detector simulation. This work shows the first direct

  20. Investigating the response of Micromegas detector to low-energy neutrons using Monte Carlo simulation

    Science.gov (United States)

    Khezripour, S.; Negarestani, A.; Rezaie, M. R.

    2017-08-01

    Micromegas detector has recently been used for high-energy neutron (HEN) detection, but the aim of this research is to investigate the response of the Micromegas detector to low-energy neutron (LEN). For this purpose, a Micromegas detector (with air, P10, BF3, 3He and Ar/BF3 mixture) was optimized for the detection of 60 keV neutrons using the MCNP (Monte Carlo N Particle) code. The simulation results show that the optimum thickness of the cathode is 1 mm and the optimum of microgrid location is 100 μm above the anode. The output current of this detector for Ar (3%) + BF3 (97%) mixture is greater than the other ones. This mixture is considered as the appropriate gas for the Micromegas neutron detector providing the output current for 60 keV neutrons at the level of 97.8 nA per neutron. Consecuently, this detector can be introduced as LEN detector.

  1. Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am–Be neutron source

    International Nuclear Information System (INIS)

    Li, Gang; Xu, Jiayun; Zhang, Jie

    2015-01-01

    Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am–Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am–Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. - Highlights: • The scope of the affected area for

  2. Neutron resonance parameters of 96Zr below 100 keV

    International Nuclear Information System (INIS)

    Musgrove, A.R.D.

    1977-08-01

    Transmission data taken at the 80 m station of the Oak Ridge Electron Linear Accelerator have provided resonance parameters for 96 Zr to 100 keV. The average level spacing and neutron strength function for s-wave neutrons were as follows: = 8 +- 2 keV and S 0 = (0.21 +- 0.10) x 10 -4 . The average p-wave neutron strength function was S 1 = (7.4 +- 2.0) x 10 -4 . (Author)

  3. Study on method of dose estimation for the Dual-moderated neutron survey meter

    International Nuclear Information System (INIS)

    Zhou, Bo; Li, Taosheng; Xu, Yuhai; Gong, Cunkui; Yan, Qiang; Li, Lei

    2013-01-01

    In order to study neutron dose measurement in high energy radiation field, a Dual-moderated survey meter in the range from 1 keV to 300 MeV mean energies spectra has been developed. Measurement results of some survey meters depend on the neutron spectra characteristics in different neutron radiation fields, so the characteristics of the responses to various neutron spectra should be studied in order to get more reasonable dose. In this paper the responses of the survey meter were calculated under different neutron spectra data from IAEA of Technical Reports Series No. 318 and other references. Finally one dose estimation method was determined. The range of the reading per H*(10) for the method estimated is about 0.7–1.6 for the neutron mean energy range from 50 keV to 300 MeV. -- Highlights: • We studied a novel high energy neutron survey meter. • Response characteristics of the survey meter were calculated by using a series of neutron spectra. • One significant advantage of the survey meter is that it can provide mean energy of radiation field. • Dose estimate deviation can be corrected. • The range of corrected reading per H*(10) is about 0.7–1.6 for the neutron fluence mean energy range from 0.05 MeV to 300 MeV

  4. Neutron capture in s-wave resonances of 56Fe, 58Ni, and 60Ni

    International Nuclear Information System (INIS)

    Wisshak, F.; Kaeppeler, F.; Reffo, G.; Fabbri, F.

    1983-07-01

    The neutron capture widths of s-wave resonances in 56 Fe (27.7 keV), 58 Ni(15.4 keV) and 60 Ni (12.5 keV) have been determined using a setup completely different from previous experiments. A pulsed 3-MV Van de Graaff accelerator and a kinematically collimated neutron beam, produced via the 7 Li (p,n) reaction, was used in the experiments. Capture gamma-rays were observed by three Moxon-Rae detectors with graphite-, bismuth-graphite-, and bismuth-converters, respectively. The samples were positioned at a neutron flight path of only 8 cm. Thus events due to capture of resonance scattered neutrons in the detectors or in surrounding materials are completely discriminated by their additional time of flight. The high neutron flux at the sample position allowed the use of very thin samples (0.15 mm-0.45 mm), avoiding large multiple scattering corrections. The data obtained with the individual detectors were corrected for the efficiency of the respective converter materials. For that purpose, detailed theoretical calculations of the capture gamma-ray spectra of the measured isotopes and of gold, which was used as a standard, were performed. The final results are: GAMMAsub(γ)(27.7 keV, 56 Fe) = 1.06 +- 0.05 eV, GAMMAsub(γ)(15.4 keV, 58 Ni) = 1.53 +- 0.10 eV and GAMMAsub(γ)(12.5 keV, 60 Ni) = 2.92 +- 0.19 eV. The accuracy obtained with the present experimental method represents an improvement of a factor 3-6 compared to previous experiments. The investigated s-wave resonances contribute 10-40% to the total capture rate of the respective isotopes in a typical fast reactor. (orig.) [de

  5. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  6. Effects of single and split doses of cobalt-60 gamma rays and 14 MeV neutrons on mouse stem cell spermatogonia.

    Science.gov (United States)

    Hacker-Klom, U B; Köhnlein, W; Göhde, W

    2000-12-01

    The long-term effects of ionizing radiation on male gonads may be the result of damage to spermatogonial stem cells. Doses of 10 cGy to 15 Gy (60)Co gamma rays or 10 cGy to 7 Gy 14 MeV neutrons were given to NMRI mice as single or split doses separated by a 24-h interval. The ratios of haploid spermatids/2c cells and the coefficients of variation of DNA histogram peaks as measures of both the cytocidal and the clastogenic actions of radiation were analyzed by DNA flow cytometry after DAPI staining. The coefficient of variation is not only a statistical examination of the data but is also used here as a measure of residual damage to DNA (i.e. a biological dosimeter). Testicular histology was examined in parallel. At 70 days after irradiation, the relative biological effectiveness for neutrons at 50% survival of spermatogonial stem cells was 3.6 for single doses and 2.8 for split doses. The average coefficient of variation of unirradiated controls of elongated spermatids was doubled when stem cells were irradiated with single doses of approximately 14 Gy (60)Co gamma rays or 3 Gy neutrons and observed 70 days later. Split doses of (60)Co gamma rays were more effective than single doses, doubling DNA dispersion at 7 Gy. No fractionation effect was found with neutrons with coefficients of variation.

  7. Tensile property changes of metals and irradiated to low doses with fission, fusion and spallation neutrons

    International Nuclear Information System (INIS)

    Heinisch, H.L.; Hamilton, M.L.; Sommer, W.F.; Ferguson, P.D.

    1992-01-01

    The objective of this work is to investigate the effects of the neutron energy spectrum in low dose irradiations on the microstructures and mechanical properties of metals. Radiation effects due to low doses of spallation neutrons are compared directly to those produced by fission and fusion neutrons. Yield stress changes of pure Cu, alumina-dispersion-strengthened Cu and AISI 316 stainless steel irradiated at 36-55 C in the Los Alamos Spallation Radiation Effects Facility (LASREF) are compared with earlier results of irradiations at 90 C using 14 MeV D-T fusion neutrons at the Rotating Target Neutron Source and fission reactor neutrons in the Omega West Reactor. At doses up to 0.04 displacements per atom (dpa), the yield stress changes due to the three quite different neutron spectra correlate well on the basis of dpa in the stainless steel and the Cu alloy. However, in pure Cu, the measured yield stress changes due to spallation neutrons were anomalously small and should be verified by additional irradiations. With the exception of pure Cu, the low dose, low temperature experiments reveal no fundamental differences in radiation hardening by fission, fusion or spallation neutrons when compared on the basis of dpa

  8. Measurement of the 232Th neutron capture cross section in the region 5 keV-150 keV

    International Nuclear Information System (INIS)

    Lobo, Georges; Corvi, Franco; Schillebeeckx, Peter; Brusegan, Antonio; Mutti, Paolo; Janeva, Natalia

    2002-01-01

    The average capture cross-section of 232 Th has been measured at the 14.37 m flight path of GELINA, IRMM-Geel, in the energy range from 5 to 150 keV. The capture events were detected by two C 6 D 6 liquid scintillators and the neutron flux was measured with a 10 B-loaded ionisation chamber. The data, corrected with the pulse-height weighting technique, have been normalised to the well-isolated and nearly saturated 232 Th (n, γ) resonances at 21.8 eV and 23.5 eV. Below 15 keV neutron energy, we do not observe the discrepancies, up to 40%, with the evaluated ENDF/B-VI data as reported by Wisshak et al.. Between 5 and 80 keV our results are about 10% systematically above the ENDF/B-VI data and approach the evaluated data between 80 and 100 keV. (author)

  9. Calculated microdose spectra for intermediate energy neutrons (1 to 100 keV)

    International Nuclear Information System (INIS)

    Al-Affan, I.A.M.; Watt, D.E.

    1983-01-01

    Basic formulae for calculation of energy deposition events due to insiders, starters, stoppers and crossers, using the continuous slowing down approximation have been modified to allow for the enhanced energy deposition in spherical volumes due to elastic scattering interactions which reduce the penetration depth of the charged particle recoils. Energy deposition spectra have been obtained for energies of 1, 10, 50, 100 keV in 0.2 μm and 1 μm tissue-equivalent spheres. From these, frequency and dose distributions in lineal energy and in specific energy density have been calculated. Also calculated for different neutron energies are values of zeta, the energy average of event size, as a function of the diameter of the sensitive site. The structure of the energy event distributions can be interpreted in terms of the basic physics. The effect of the modifications to the basic formulae is to increase the number of energy deposition events due to insiders and to decrease the number of starters, stoppers and crossers. The degree of the effect increases with decreasing neutron energy, increasing sphere size, and the change is most significant for low energy deposition events. (author)

  10. Calculated microdose spectra for intermediate energy neutrons (1 to 100 keV)

    Energy Technology Data Exchange (ETDEWEB)

    Al-Affan, I.A.M.; Watt, D.E. (Dundee Univ. (UK). Dept. of Medical Biophysics); Colautti, P.; Talpo, G. (Laboratori Nazionali dell' Infn, 35020, Legnaro (Padova) (Italy))

    1983-01-01

    Basic formulae for calculation of energy deposition events due to insiders, starters, stoppers and crossers, using the continuous slowing down approximation have been modified to allow for the enhanced energy deposition in spherical volumes due to elastic scattering interactions which reduce the penetration depth of the charged particle recoils. Energy deposition spectra have been obtained for energies of 1, 10, 50, 100 keV in 0.2 ..mu..m and 1 ..mu..m tissue-equivalent spheres. From these, frequency and dose distributions in lineal energy and in specific energy density have been calculated. Also calculated for different neutron energies are values of zeta, the energy average of event size, as a function of the diameter of the sensitive site. The structure of the energy event distributions can be interpreted in terms of the basic physics. The effect of the modifications to the basic formulae is to increase the number of energy deposition events due to insiders and to decrease the number of starters, stoppers and crossers. The degree of the effect increases with decreasing neutron energy, increasing sphere size, and the change is most significant for low energy deposition events.

  11. Yield of chromosomal aberrations and recoil particle range in Chineses hamster fibroblasts exposed to 8.5 to 500 keV neutrons

    International Nuclear Information System (INIS)

    Sturelid, S.; Bergman, R.

    1976-01-01

    Induction of chromatid aberrations in S-phase Chinese hamster fibroblasts has been studied for irradiation by 60 Co gamma rays and neutrons of average energy 8.5, 45, 83, 200 and 500 keV. At 10 per cent aberration level the relative biological afficiency varied between 2.2 +- 0.6 (at 8.5 keV) and a maximum of 47 +- 9 (at 200 keV). The neutron generated recoils have short range in comparison to chromosomal dimensions. The strong variation with neutron energy is therefore not necessarily reflecting variations in the average linear energy transfer. Good agreement between experimental and predicted response was obtained when effects ascribed to range were considered. A critical volume within which primary lesions should occur in order to make chromosomal aberrations probable was derived. The corresponding site radius was estimated to be 1-3 μm. (author)

  12. Oxygen enhancement ratio (OER) to Neutron and Co-60 γ ray

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Ji, Young Hoon; Lee, Yong Min; Kim Kyeoung Jung

    1997-01-01

    Experiments in vitro, using human cell lines was carried out in order to establish whether or not there was a difference between oxygen enhancement ratio (OER) of neutron and Co-60 γ-ray and to determine OER dependence on radiation dose. MG-63 cell line and H-460 cell line were defined as the most sensitive cell line to neutron among our laboratory holding cell lines through preliminary study. Anoxia as was produced in glove box. The box was flushed for one hour with a mixture of 5 % CO 2 in ultrapure N 2 (total oxygen concentration < 10 ppm) and irradiated with neutron and Co-60 γ-ray. Oxic condition was same as anoxic condition except being irradiated in general air condition. The lower OER was observed in neutron than in Co-60 γ-ray. The dose dependence of OER was observed in neutron and Co-60 γ-ray all. But the dose dependence of the OER is somewhat larger for Co-60 γ-ray than for neutron. In the range of 1 to 8 Gy, the OER for photon and neutron range from 1.54 to 1.94 and 1.23 to 1.26 in MG-63 cell line. In case of H-460 the OER for Co-60 γ-ray and neutron range from 1.24 to 1.60 and 1.06 to 1.07 respectively. (author). 19 refs., 5 tabs., 5 figs

  13. Experimental studies of keV energy neutron-induced reactions relevant to astrophysics and nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Shima, T.; Kii, T.; Kikuchi, T.; Okazaki, F.; Kobayashi, T.; Baba, T.; Nagai, Y. [Tokyo Inst. of Tech. (Japan). Faculty of Science; Igashira, M.

    1997-03-01

    Nuclear reactions induced by keV energy neutrons provide a plenty of informations for studies of both astrophysics and nuclear physics. In this paper we will show our experimental studies of neutron- induced reactions of light nuclei in the keV energy region by means of a pulsed keV neutron beam and high-sensitivity detectors. Also we will discuss astrophysical and nuclear-physical consequences by using the obtained results. (author)

  14. Stimulation growth effect of Eriocheir sinensis treated with low-dose neutron

    International Nuclear Information System (INIS)

    Luo Keyong; Liu Chunquan; Xu Lixin; Peng Zhangji

    2006-01-01

    This paper was dealt with the relationship between biochemical indexes and different growth stages of Eriocheir sinensis megalopa treated with Low-dose Neutron at 55.24 to 73.66 mGy. It showed that some biochemical component indexes were increased, such as-SH group in protain (between 23.40% to 69.59%), albumen (between 4.99% to 22.6%) and Hyp compared with CK. However, free radical level (between 7.67% to 32.68%) and AKP were decreased. The carapace color was turned into darker than that of CK; Antibacterial immunity of younger crab during the growing stage was increased, the body size of treated Eriocheir sinensis megalopa became uniform and early sexual maturity was inhibited in a certain degree with a low dose neutron treatment. (authors)

  15. Low-dose neutron dose response of zebrafish embryos obtained from the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Kong, E.Y.; Konishi, T.; Kobayashi, A.; Suya, N.; Cheng, S.H.; Yu, K.N.

    2015-01-01

    The dose response of embryos of the zebrafish, Danio rerio, irradiated at 5 h post fertilization (hpf) by 2-MeV neutrons with ≤100 mGy was determined. The neutron irradiations were made at the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility in the National Institute of Radiological Sciences (NIRS), Chiba, Japan. A total of 10 neutron doses ranging from 0.6 to 100 mGy were employed (with a gamma-ray contribution of 14% to the total dose), and the biological effects were studied through quantification of apoptosis at 25 hpf. The responses for neutron doses of 10, 20, 25, and 50 mGy approximately fitted on a straight line, while those for neutron doses of 0.6, 1 and 2.5 mGy exhibited neutron hormetic effects. As such, hormetic responses were generically developed by different kinds of ionizing radiations with different linear energy transfer (LET) values. The responses for neutron doses of 70 and 100 mGy were significantly below the lower 95% confidence band of the best-fit line, which strongly suggested the presence of gamma-ray hormesis. - Highlights: • Neutron dose response was determined for embryos of the zebrafish, Danio rerio. • Neutron doses of 0.6, 1 and 2.5 mGy led to neutron hormetic effects. • Neutron doses of 70 and 100 mGy accompanied by gamma rays led to gamma-ray hormesis

  16. Neutron capture cross sections of 69Ga and 71Ga at 25 keV and Epeak = 90 keV

    Science.gov (United States)

    Göbel, Kathrin; Beinrucker, Clemens; Erbacher, Philipp; Fiebiger, Stefan; Fonseca, Micaela; Heftrich, Michael; Heftrich, Tanja; Käppeler, Franz; Krása, Antonin; Lederer-Woods, Claudia; Plag, Ralf; Plompen, Arjan; Reifarth, René; Schmidt, Stefan; Sonnabend, Kerstin; Weigand, Mario

    2017-09-01

    We measured the neutron capture cross sections of 69Ga and 71Ga for a quasi-stellar spectrum at kBT = 25 keV and a spectrum with a peak energy at 90 keV by the activation technique at the Joint Research Centre (JRC) in Geel, Belgium. Protons were provided by an electrostatic Van de Graaff accelerator to produce neutrons via the reaction 7Li(p,n). The produced activity was measured via the γ emission of the product nuclei by high-purity germanium detectors. We present preliminary results.

  17. The effect of low-dose neutron irradiation on extracellular matrix

    International Nuclear Information System (INIS)

    Chen Tiehe; Lu Yongjie; Chai Mingsheng; Peng Wulin; Yang Yifang; Pan Yan; Chen Jinguo

    2003-01-01

    Projective: To study the effect of neutron irradiation on extracellular matrix. Methods: 120 male wistar rats were divided into four groups at random, and then exposed to neutron of 252 Cf-source at the doses of 0, 0.29, 0.62 and 1.20 Gy, respectively. After the exposure of 3 days, 1 month and 2 months, the rats were sacrificed and lung tissue specimens stored at -30 degree C. Hyaluronan, laminin, type III procollagen and type IV collagen in the lung tissue were detected by the method of radioimmunoassay. Results: The differences of the levels of hyaluronan in lung tissue among the groups were unsignificant. The levels of laminin in 0.29, 0.62 and 1.20 Gy groups after the 3-day exposure were remarkably different to those of the control group, and unable to recover completely even 2 months after the exposure. The levels of type IV collagen in higher three irradiated groups were all higher, but not significantly. The levels of type III procollagen in the early stage after exposure were higher, and later they lowered. Conclusion: The levels of some components of extracellular matrix in the lung tissue of rat can be changed by low-dose of neutron irradiation, but their variational modes and degrees depend on the dose of neutron irradiation and the length of period after exposure

  18. Neutron capture resonances in 56Fe and 58Fe in the energy range from 10 to 100 keV

    International Nuclear Information System (INIS)

    Kaeppeler, F.; Wisshak, K.; Hong, L.D.

    1982-11-01

    The neutron capture cross section of 56 Fe and 58 Fe has been measured in the energy range from 10 to 250 keV relative to the gold standard. A pulsed 3 MV Van de Graaff accelerator and the 7 Li(p, n) reaction served as a neutron source. Capture gamma rays were detected by two C 6 D 6 detectors, which were operated in coincidence and anticoincidence mode. Two-dimensional data acquisition allowed to apply the pulse height weighting technique off-line. The samples were located at a flight path of 60 cm. The total time resolution was 1.2 ns thus allowing for an energy resolution of 2 ns/m. The experimental set-up was optimized with respect to low background and low neutron sensitivity. The additional flight path of 4 cm from the sample to the detector was sufficient to discriminate capture of sample scattered neutrons by the additional time of flight. In this way reliable results were obtained even for the strong s-wave resonances of both isotopes. The experimental capture yield was analyzed with the FANAC code. The energy resolution allowed to extract resonance parameters in the energy range from 10 to 100 keV. The individual systematic uncertainties of the experimental method are discussed in detail. They were found to range between 5 and 10% while the statistical uncertainty is 3-5% for most of the resonances. A comparison to the results of other authors exhibits in case of 56 Fe systematic differences of 7-11%. For 58 Fe the present results differ up to 50% from the only other measurement for this isotope. (orig.) [de

  19. Design study of a time-of-flight neutron spectrometer for JT-60U

    International Nuclear Information System (INIS)

    Elevant, T.; Hoek, M.; Nishitani, Takeo.

    1993-06-01

    A time-of-flight neutron spectrometer is proposed for measurements of neutron energy spectra from deuterium-deuterium reactions in JT-60U tokamak plasmas. The sensitivity of the instrument is 2 · 10 -2 cm 2 , energy resolution is 4.5 % (FWHM) and maximum useful count-rate is 6 kHz. Analysis of neutron energy spectra will provide information on central ion temperatures larger than ∼ 4 keV with an accuracy of ± 10 %, and neutron source fraction from reactions between thermal ions with an accuracy of ± 15 %. The minimum time required for data acquisition is 0.1 s. (author)

  20. Resonance parameters for measured keV neutron capture cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Musgrove, A.R. de L

    1969-05-01

    All available neutron capture cross sections in the keV region ({approx} to 100 keV) have been fitted with resonance parameters. Capture cross sections for nuclides with reasonably well known average s-wave parameters, but no measured cross section, have been calculated and tabulated using p-and d- wave strength functions interpolated between fitted values. Several of these nuclides are of interest in the theory of slow nucleosynthesis of heavy elements in stars, and the product of cosmic abundance (due to the s-process) and capture cross section at 30 keV has been plotted versus mass number. (author)

  1. Personnel neutron dose assessment upgrade: Volume 2, Field neutron spectrometer for health physics applications

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Reece, W.D.; Miller, S.D.

    1988-07-01

    Both the (ICRP) and the (NCPR) have recommended an increase in neutron quality factors and the adoption of effective dose equivalent methods. The series of reports entitled Personnel Neutron Dose Assessment Upgrade (PNL-6620) addresses these changes. Volume 1 in this series of reports (Personnel Neutron Dosimetry Assessment) provided guidance on the characteristics, use, and calibration of personnel neutron dosimeters in order to meet the new recommendations. This report, Volume 2: Field Neutron Spectrometer for Health Physics Applications describes the development of a portable field spectrometer which can be set up for use in a few minutes by a single person. The field spectrometer described herein represents a significant advance in improving the accuracy of neutron dose assessment. It permits an immediate analysis of the energy spectral distribution associated with the radiation from which neutron quality factor can be determined. It is now possible to depart from the use of maximum Q by determining and realistically applying a lower Q based on spectral data. The field spectrometer is made up of two modules: a detector module with built-in electronics and an analysis module with a IBM PC/reg sign/-compatible computer to control the data acquisition and analysis of data in the field. The unit is simple enough to allow the operator to perform spectral measurements with minimal training. The instrument is intended for use in steady-state radiation fields with neutrons energies covering the fission spectrum range. The prototype field spectrometer has been field tested in plutonium processing facilities, and has been proven to operate satisfactorily. The prototype field spectrometer uses a 3 He proportional counter to measure the neutron energy spectrum between 50 keV and 5 MeV and a tissue equivalent proportional counter (TEPC) to measure absorbed neutron dose

  2. Direct capture of low-energy neutrons by {sup 16}O

    Energy Technology Data Exchange (ETDEWEB)

    Kitazawa, Hideo [Tokyo Inst. of Tech., Nagatsuta, Yokohama (Japan). Interdisciplinary Graduate School of Science; Igashira, Masayuki

    1998-03-01

    A dispersive optical potential for the interaction between low-energy neutrons and {sup 16}O-nuclei is derived from a dispersion relation based on the Feshbach generalized optical model. This potential is applied to direct-capture model calculations in explaining the observed off-resonance capture transitions to the ground (5/2{sup +}) and 871 keV(1/2{sup +}) levels in {sup 17}O at neutron energies of 20-70 keV. The model calculations take account of the spatial nonlocality of the neutron-nucleus interaction potential. (author)

  3. Low energy, high power injection in JT-60 NBI

    International Nuclear Information System (INIS)

    Mizuno, Makoto; Dairaku, Masayuki; Horiike, Hiroshi

    1988-05-01

    JT-60 neutral beam injector (JT-60 NBI) is designed to inject 20 MW neutral hydrogen beam at energies of 70 ∼ 100 keV and the injection power decreases significantly at low energies (∼40 keV). For the extention of operation region aiming at the low density plasma heating and achieving H-mode by plasma periphery heating, increment of the injection power at low beam energies was required. The single-stage acceleration system was investigated in advance at the Prototype Injector Unit. From this result, the total injection power of 17 MW at 40 keV, 48 A per source was expected at the JT-60 NBI. This system was adopted in the JT-60 NBI from June, 1987 to July, 1987 and 17.6 MW neutral beam injection power was achieved. In the NB heating experiment, the H-mode transition phenomena was observed in JT-60 plasma. (author)

  4. The neutron dose equivalent around high energy medical electron linear accelerators

    Directory of Open Access Journals (Sweden)

    Poje Marina

    2014-01-01

    Full Text Available The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator that consist of 10B and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation. In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the 60Co decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.

  5. 2 keV filters of quasi-mono-energetic neutrons

    International Nuclear Information System (INIS)

    Adib, M.; Habib, N.; El-Mesiry, M.S.; Bashter, I.I.; Saleh, A.; Fathallah, M.

    2013-01-01

    A simulation study for the production of 2 keV filters of quasi-mono-energetic neutrons based on the deep interference minima in the 45 Sc total cross-section was carried out. A computer code QMENF-II was adapted to calculate the optimum amounts of the 45 Sc as a main filter element and additional component ones to obtain sufficient intensity at high resolution and purity of the filtered quasi-mono-energetic neutrons. The emitted neutron spectrum from nuclear reactor and from the reaction of 2.6 MeV protons on a lithium fluoride target at the accelerator beam port, are used for simulation

  6. DIANE, a simulation code for the interaction of neutrons with living tissues. Application to low doses of fast neutrons on human tumoral cells

    International Nuclear Information System (INIS)

    Nenot, M.L.

    2003-07-01

    Our work deals with the irradiation of cells and living tissues by 14 MeV neutrons at very low doses (a few 10 -2 Gy). Such experiments require an accurate knowledge of the values of neutron dose rates and fluences at the level of cell cultures. We have performed measurements of fluence rates through an activation method applied to gold and copper foils. The fluence rate is deduced from the gamma rays emitted by the irradiated foils. Neutron doses and dose rates have been measured through varied methods: PIN diodes, ionization tissue equivalent chambers, and Geiger-Mueller counters. We have designed the DIANE code to simulate the impact of energetic neutrons on cells. This code can be used with isolated cells or macroscopic tissues, it takes into account the roles of the ionisation electrons produced by recoil nuclei entering the cell. This point is all the more important since recent works have highlighted the impact of very low energy electrons on DNA. (A.C.)

  7. Effect of pulsed dose in simultaneous and sequential irradiation of V-79 cells by 14.8 MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Gould, M.N.; Schell, M.C.; Pearson, D.W.

    1983-01-01

    The effect of irradiating V-79 Chinese hamster ovary cells with a mixture of 40% 14.8-MeV neutrons and 60% 60 Co photons with simultaneous or sequential exposures is investigated. Target doses are obtained by irradiating cell samples with 3-minute-long pulses of alternating neutrons and photons (in the sequential case) or with mixed neutrons and photons followed by equal beam-off periods to insure equal total-exposure times for sequenced and simultaneous irradiations. We observe qualitative differences between the survival results under each beam configuration that confirms earlier observations

  8. Study on the keV neutron capture reaction in 56Fe and 57Fe

    Science.gov (United States)

    Wang, Taofeng; Lee, Manwoo; Kim, Guinyun; Ro, Tae-Ik; Kang, Yeong-Rok; Igashira, Masayuki; Katabuchi, Tatsuya

    2014-03-01

    The neutron capture cross-sections and the radiative capture gamma-ray spectra from the broad resonances of 56Fe and 57Fe in the neutron energy range from 10 to 90keV and 550keV have been measured with an anti-Compton NaI(Tl) detector. Pulsed keV neutrons were produced from the 7Li 7Be reaction by bombarding the lithium target with the 1.5ns bunched proton beam from the 3MV Pelletron accelerator. The incident neutron spectrum on a capture sample was measured by means of a time-of-flight (TOF) method with a 6Li -glass detector. The number of weighted capture counts of the iron or gold sample was obtained by applying a pulse height weighting technique to the corresponding capture gamma-ray pulse height spectrum. The neutron capture gamma-ray spectra were obtained by unfolding the observed capture gamma-ray pulse height spectra. To achieve further understanding on the mechanism of neutron radiative capture reaction and study on physics models, theoretical calculations of the -ray spectra for 56Fe and 57Fe with the POD program have been performed by applying the Hauser-Feshbach statistical model. The dominant ingredients to perform the statistical calculation were the Optical Model Potential (OMP), the level densities described by the Mengoni-Nakajima approach, and the -ray transmission coefficients described by -ray strength functions. The comparison of the theoretical calculations, performed only for the 550keV point, show a good agreement with the present experimental results.

  9. The new remcounter LB6411: Measurement of neutron ambient dose equivalent H*(10) according to ICRP60 with high sensitivity

    International Nuclear Information System (INIS)

    Klett, A.; Burgkhardt, B.

    1996-01-01

    Since the International Commission on Radiological Protection has issued in publication ICRP60 new recommendations on radiation protection quantities, in neutron monitoring there is now increasing Interest in commercially available instruments optimized and calibrated for the measurement of ambient dose equivalent H*(10). Therefore within a joint cooperation between the Research Center Karlsruhe and EG ampersand G Berthold the neutron-dose-rate meter LB6411 was newly developed. The detector system with integrated electronics has a 3 He proportional counter tube centered in a moderating sphere. The response between thermal energies and 20 MeV was optimized with the help of extensive MCNP Monte-Carlo calculations. The instrument has extremely high sensitivity of approximately 3 counts per nSv and can be used both as a portable or as a stationary neutron monitor. Fluence responses and angular dependencies had been measured in monoenergetic neutron beams provided by the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. The ambient dose equivalent response of the LB6411 is reported over the whole energy range

  10. Low Energy Scanned Electron-Beam Dose Distribution in Thin Layers

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Hjortenberg, P. E.; Pedersen, Walther Batsberg

    1975-01-01

    Thin radiochromic dye film dosimeters, calibrated by means of calorimetry, make possible the determination of absorbed-dose distributions due to low-energy scanned electron beam penetrations in moderately thin coatings and laminar media. For electrons of a few hundred keV, calibrated dosimeters...... of about 30–60 μm thickness may be used in stacks or interleaved between layers of materials of interest and supply a sufficient number of experimental data points throughout the depth of penetration of electrons to provide a depth-dose curve. Depth doses may be resolved in various polymer layers...... on different backings (wood, aluminum, and iron) for scanned electron beams (Emax = 400 keV) having a broad energy spectrum and diffuse incidence, such as those used in radiation curing of coatings, textiles, plastics, etc. Theoretical calculations of such distributions of energy depositions are relatively...

  11. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes

    International Nuclear Information System (INIS)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-01

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions

  12. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  13. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV

    International Nuclear Information System (INIS)

    Donath, T; Brandstetter, S; Commichau, S; Hofer, P; Lüthi, B; Schneebeli, M; Schulze-Briese, C; Cibik, L; Krumrey, M; Marggraf, S; Müller, P; Wernecke, J

    2013-01-01

    The PILATUS detector module was characterized in the PTB laboratory at BESSY II comparing modules with 320 μm thick and newly developed 450 μm and 1000 μm thick silicon sensors. Measurements were carried out over a wide energy range, in-vacuum from 1.75 keV to 8.8 keV and in air from 8 keV to 60 keV. The quantum efficiency (QE) was measured as a function of energy and the spatial resolution was measured at several photon energies both in terms of the modulation transfer function (MTF) from edge profile measurements and by directly measuring the point spread function (PSF) of a single pixel in a raster scan with a pinhole beam. Independent of the sensor thickness, the measured MTF and PSF come close to those for an ideal pixel detector with the pixel size of the PILATUS detector (172 × 172 μm 2 ). The measured QE follows the values predicted by calculation. Thicker sensors significantly enhance the QE of the PILATUS detectors for energies above 10 keV without impairing the spatial resolution and noise-free detection. In-vacuum operation of the PILATUS detector is possible at energies as low as 1.75 keV.

  14. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV

    Science.gov (United States)

    Donath, T.; Brandstetter, S.; Cibik, L.; Commichau, S.; Hofer, P.; Krumrey, M.; Lüthi, B.; Marggraf, S.; Müller, P.; Schneebeli, M.; Schulze-Briese, C.; Wernecke, J.

    2013-03-01

    The PILATUS detector module was characterized in the PTB laboratory at BESSY II comparing modules with 320 μm thick and newly developed 450 μm and 1000 μm thick silicon sensors. Measurements were carried out over a wide energy range, in-vacuum from 1.75 keV to 8.8 keV and in air from 8 keV to 60 keV. The quantum efficiency (QE) was measured as a function of energy and the spatial resolution was measured at several photon energies both in terms of the modulation transfer function (MTF) from edge profile measurements and by directly measuring the point spread function (PSF) of a single pixel in a raster scan with a pinhole beam. Independent of the sensor thickness, the measured MTF and PSF come close to those for an ideal pixel detector with the pixel size of the PILATUS detector (172 × 172 μm2). The measured QE follows the values predicted by calculation. Thicker sensors significantly enhance the QE of the PILATUS detectors for energies above 10 keV without impairing the spatial resolution and noise-free detection. In-vacuum operation of the PILATUS detector is possible at energies as low as 1.75 keV.

  15. 56Fe resonance parameters for neutron energies up to 850 keV

    International Nuclear Information System (INIS)

    Perey, C.M.; Perey, F.G.; Harvey, J.A.; Hill, N.W.; Larson, N.M.

    1990-12-01

    High-resolution neutron measurements for 56 Fe-enriched iron targets were made at the Oak Ridge Electron Linear Accelerator (ORELA) in transmission below 20 MeV and in differential elastic scattering below 5 MeV. Transmission measurements were also performed with a natural iron target below 160 keV. The transmission data were analyzed from 5 to 850 keV with the multilevel R-matrix code SAMMY which uses Bayes' theorem for the fitting process. This code provides energies and neutron widths of the resonances inside the 5- to 850-keV energy region, as well as possible parameterization for resonances external to the analyzed region to describe the smooth cross section from a few eV to 850 keV. The resulting set of resonance parameters yields the accepted values for the thermal total and capture cross sections. The differential elastic-scattering data at several scattering angles were compared to theoretical calculations from 40 to 850 keV using the R-matrix code RFUNC based on the Blatt-Biedenharn formalism. Various combinations of spin and parity were tried to predict cross sections for the well defined ell > 0 resonances; comparison of these predictions with the data allowed us to determine the most likely spin and parity assignments for these resonances. The results of a capture data analysis by Corvi et al. (COR84), from 2 to 350 keV, were combined with our results to obtain the radiation widths of the resonances below 350 keV observed in transmission, capture, and differential elastic-scattering experiments

  16. Limiting values for the RBE of fission neutrons at low doses for life shortening in mice

    International Nuclear Information System (INIS)

    Storer, J.B.; Mitchell, T.J.

    1984-01-01

    The authors have analyzed recently published data on the effects of low doses of fission neutrons on the mean survival times of mice. The analysis for single-dose exposures was confined to doses of 20 rad or less, while for fractionated exposures only total doses of 80 rad or less were considered. They fitted the data to the frequently used power function model: life shortening = βD/sup γ/, where D is the radiation dose. They show that, at low doses per fraction, either the effects are not additive or the dose-effect curve for single exposures cannot show a greater negative curvature than about the 0.9 power of dose. Analysis of the data for γ rays showed that an exponent of 1.0 gave an acceptable fit. They conclude that at neutron doses of 20 rad or less the RBE for life shortening is constant and ranges from 13 to 22 depending on mouse strain and sex

  17. V79 survival following simultaneous or sequential irradiation by 14.8-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1981-01-01

    A unique tandem source irradiation facility, comprised of an intense d-T neutron source and a 60 Co teletherapy unit, has been used to investigate biological response for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log phase growth, were irradiated at 37 0 C by either 14.8 MeV neutrons, 60 Co or by a mixture of 40% neutrons - 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons than was measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable and for determination of environmental hazards to people occupationally exposed to low levels of photons and neutrons

  18. Induction and disappearance of G2 chromatid breaks in lymphocytes after low doses of low LET γ - rays and high LET fast neutrons

    International Nuclear Information System (INIS)

    Vral, Anne; Thierens, Hubert; Baeyens, Ans; De Ridder, Leo

    2001-01-01

    In view of the potential importance of the G2 assay for detecting chromosomal radiosensitivity and possible predisposition to cancer the need to elucidate the mechanism underlying the formation of chromatid breaks, observed with the G2 assay after low dose irradiation, has been recognised. In this study we irradiated blood samples of 4 healthy donors with low LET γ-rays and high LET neutrons, which initially produce the same number of dsb but of a different quality. By means of the G2 assay, we determined the number of chromatid breaks induced by γ-rays and neutrons and compared the kinetics of chromatid break rejoining for radiations of different quality. In a first set of experiments a dose-response curve for the formation of chromatid breaks was carried out for γ-rays and neutrons with doses ranging between 0.1 and 0.5 Gy. In a second set of experiments the kinetics of chromatid break formation and disappearance was investigated after a dose of 0.5 Gy using post-irradiation times ranging between 0.5 h and 3.5 h. For the highest dose of 0.5 Gy the number of isochromatid breaks were also scored. No significant differences in the number of chromatid breaks were observed between low LET γ-rays and high LET neutrons for the 4 donors at any of the doses given. The dose response curves for the formation of chromatid breaks are linear for both radiation qualities and RBE values equal to one were obtained. Scoring of isochromatid breaks at the highest dose of 0.5 Gy revealed that high LET neutrons are however more effective at inducing isochromatid breaks (RBE of 6.2). The rejoining experiments further showed that the kinetics of disappearance of chromatid breaks following irradiation with low LET γ-rays or high-LET neutrons are not significantly different. T 1/2 0.92 h for γ-rays and t 1/2 = 0.84 h for neutrons were obtained. In conclusion, our results show that at low doses of radiation the induction as well as the disappearance of G2 chromatid breaks is LET

  19. Characterization of Monoenergetic Low Energy Neutron Fields with the {mu}TPC Detector

    Energy Technology Data Exchange (ETDEWEB)

    Golabek, C.; Lebreton, L.; Petit, M. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Billard, J.; Grignon, C.; Bosson, G.; Bourrion, O.; Guillaudin, O.; Mayet, F.; Richer, J.-P.; Santos, D. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph (France)

    2011-12-13

    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 2 keV up to 1 MeV. We present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of such low energy neutron fields.

  20. 150 keV accelerator as pulsed neutron source; Acelerador de 150 keV como fuente de neutrones pulsada

    Energy Technology Data Exchange (ETDEWEB)

    Cordero, F

    1970-07-01

    The project of a 150 keV Cockcroft-Walton accelerator built at J.E.N. is described. Beam currents of more than 10 mA, with a neutron intensity of 10{sup 1}1 n.s{sup 1}, are obtained. Also, we report some research made in connection with that project. The role of the contamination in the vacuum system and the performance of the pumps and gauges pumping deuterium gas are studied. Sinusoidal pulses are employed as an analysis method of the discharge in the ion source and the performance of the extracting-focusing system. The parameters of the beam leaving the ion source have been determined; these are used to calculate the electrostatic lenses with the gaussian optics. Measurements concerning deuterium and tritium targets as neutron sources have been made and the processes affecting their practical service life are analyzed. (Author) 71 refs.

  1. Neutron Fluence and Energy Reconstruction with the LNE-IRSN/MIMAC Recoil Detector MicroTPC at 27 keV

    Energy Technology Data Exchange (ETDEWEB)

    Maire, D.; Lebreton, L.; Querre, Ph. [Institute for Radioprotection and Nuclear Safety - IRSN, site of Cadarache, 13115 Saint Paul lez Durance (France); Bosson, G.; Guillaudin, O.; Muraz, J.F.; Riffard, Q.; Santos, D. [Laboratoire de Physique Subatomique et de Cosmologie - LPSCCNRSIN2P3/ UJF/INP, 38000 Grenoble (France)

    2015-07-01

    The French Institute for Radiation protection and Nuclear Safety (IRSN), designated by the French Metrology Institute (LNE) for neutron metrology, is developing a time projection chamber using a Micromegas anode: microTPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV - 5 MeV with a primary procedure. The time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulation of the detector response. The μTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27 keV and 144 keV are shown and compared to the complete detector response simulation. This work

  2. Production of low energy gamma rays by neutron interactions with fluorine for incident neutron energies between 0.1 and 20 MeV

    International Nuclear Information System (INIS)

    Morgan, G.L.; Dickens, J.K.

    1975-06-01

    Differential cross sections for the production of low-energy gamma rays (less than 240 keV) by neutron interactions in fluorine have been measured for neutron energies between 0.1 and 20 MeV. The Oak Ridge Electron Linear Accelerator was used as the neutron source. Gamma rays were detected at 92 0 using an intrinsic germanium detector. Incident neutron energies were determined by time-of-flight techniques. Tables are presented for the production cross sections of three gamma rays having energies of 96, 110, and 197 keV. (14 figures, 3 tables) (U.S.)

  3. Thermal neutron equivalent doses assessment around KFUPM neutron source storage area using NTDs

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Fazal-ur-Rehman; Al-Haddad, M.N.; Al-Jarrallah, M.I.; Nassar, R

    2002-07-01

    Area passive neutron dosemeters based on nuclear track detectors (NTDs) have been used for 13 days to assess accumulated low doses of thermal neutrons around neutron source storage area of the King Fahd University of Petroleum and Minerals (KFUPM). Moreover, the aim of this study is to check the effectiveness of shielding of the storage area. NTDs were mounted with the boron converter on their surface as one compressed unit. The converter is a lithium tetraborate (Li{sub 2}B{sub 4}O{sub 7}) layer for thermal neutron detection via {sup 10}B(N,{alpha}){sup 7}Li and {sup 6}Li(n,{alpha}){sup 3}H nuclear reactions. The area passive dosemeters were installed on 26 different locations around the source storage area and adjacent rooms. The calibration factor for NTD-based area passive neutron dosemeters was found to be 8.3 alpha tracks.cm{sup -2}.{mu}Sv{sup -1} using active snoopy neutron dosemeters in the KFUPM neutron irradiation facility. The results show the variation of accumulated dose with locations around the storage area. The range of dose rates varied from as low as 40 nSv.h{sup -1} up to 11 {mu}Sv.h{sup -1}. The study indicates that the area passive neutron dosemeter was able to detect accumulated doses as low as 40 nSv.h{sup -1}, which could not be detected with the available active neutron dosemeters. The results of the study also indicate that an additional shielding is required to bring the dose rates down to background level. The present investigation suggests extending this study to find the contribution of doses from fast neutrons around the neutron source storage area using NTDs through proton recoil. The significance of this passive technique is that it is highly sensitive and does not require any electronics or power supplies, as is the case in active systems. (author)

  4. Some thoughts on tolerance, dose, and fractionation in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gahbauer, R.; Goodman, J.; Blue, T.

    1988-01-01

    Unique to boron neutron capture therapy, the tolerance very strongly depends on the boron concentration in normal brain, skin and blood. If one first considers the ideal situation of a 2 KeV beam and a compound clearing from normal tissues and blood, the tolerance dose to epithermal beams relates to the maximum tolerated capture gamma dose and capture high LET dose, H (n,gamma)D and N(n,p) 14 C. The authors can relate this gamma and high LET dose to known clinical experience. Assuming gamma and high LET dose ratios as given by Fairchild and Bond, one may first choose a clearly safe high LET whole brain dose and calculate the unavoidably resulting gamma dose. To a first approximation 500 cGy of high LET dose results in 3,000 cGy gamma dose. One can speculate that this approximates the tolerance of whole brain to the 2 KeV beam with no contributing boron dose if the radiation is fractionated. It would clearly be beyond tolerance in a single fraction where most therapists would be uncomfortable to deliver even one third of the above doses

  5. Biophysical interpretation of the response of Chinese hamster cells to 24 keV neutrons

    International Nuclear Information System (INIS)

    Holt, P.D.

    1988-01-01

    The response of V79 Chinese hamster cells to a 24 keV neutron spectrum has been compared with data for the response of V79 cells to a range of higher neutron energies (up to 15 MeV). The linear energy transfer (LET) distributions of the neutron spectra were calculated and the expected responses of the cells to the different spectra were calculated using published track-segment data on the response of V79 cells to charged particles with various LET values. The response of the cells to 24 keV neutrons was predicted satisfactorily by the LET distribution, in spite of the fact that the maximum range of the recoil protons is only 0.5 μm. The response was not correctly predicted by the microdosimetric parameter y-bar D * evaluated in a 1 μm diameter sphere. (author)

  6. Effects of low-dose gamma and neutron radiation on genotoxicity and cytotoxicity of reticulocytes in a mouse model

    International Nuclear Information System (INIS)

    Phan, N.; McFarlane, N.M.; Lemon, J.; Boreham, D.R.

    2008-01-01

    Using a successful new automation of micronucleated reticulocyte (MN-RET) scoring, the effects of low-dose (< 1.0 Gy) gamma and neutron radiation on genotoxicity and cytotoxicity of reticulocytes (RET) in a mouse model were investigated. Gamma and neutron irradiation induced significant (p<0.001) increases in the levels of %MN-RET and decreases in the levels of %RET (p<0.001) as the dose level increased. Increasing dose levels showed that gamma radiation induced significantly (p<0.05) more %MN-RET and more %RET than neutron radiation. The results suggest that neutron irradiation may be more cytotoxic (less %RET) than gamma irradiation; however, gamma irradiation may be producing cells with more chromosomal aberrations (more %MN-RET) than neutron irradiation. (author)

  7. Effects of low-dose gamma and neutron radiation on genotoxicity and cytotoxicity of reticulocytes in a mouse model

    Energy Technology Data Exchange (ETDEWEB)

    Phan, N.; McFarlane, N.M.; Lemon, J.; Boreham, D.R. [McMaster Univ., Medical Physics and Applied Radiation Sciences Unit, Hamilton, Ontario (Canada)

    2008-07-01

    Using a successful new automation of micronucleated reticulocyte (MN-RET) scoring, the effects of low-dose (< 1.0 Gy) gamma and neutron radiation on genotoxicity and cytotoxicity of reticulocytes (RET) in a mouse model were investigated. Gamma and neutron irradiation induced significant (p<0.001) increases in the levels of %MN-RET and decreases in the levels of %RET (p<0.001) as the dose level increased. Increasing dose levels showed that gamma radiation induced significantly (p<0.05) more %MN-RET and more %RET than neutron radiation. The results suggest that neutron irradiation may be more cytotoxic (less %RET) than gamma irradiation; however, gamma irradiation may be producing cells with more chromosomal aberrations (more %MN-RET) than neutron irradiation. (author)

  8. Neutron organ dose and the influence of adipose tissue

    Science.gov (United States)

    Simpkins, Robert Wayne

    Neutron fluence to dose conversion coefficients have been assessed considering the influences of human adipose tissue. Monte Carlo code MCNP4C was used to simulate broad parallel beam monoenergetic neutrons ranging in energy from thermal to 10 MeV. Simulated Irradiations were conducted for standard irradiation geometries. The targets were on gender specific mathematical anthropomorphic phantoms modified to approximate human adipose tissue distributions. Dosimetric analysis compared adipose tissue influence against reference anthropomorphic phantom characteristics. Adipose Male and Post-Menopausal Female Phantoms were derived introducing interstitial adipose tissue to account for 22 and 27 kg additional body mass, respectively, each demonstrating a Body Mass Index (BMI) of 30. An Adipose Female Phantom was derived introducing specific subcutaneous adipose tissue accounting for 15 kg of additional body mass demonstrating a BMI of 26. Neutron dose was shielded in the superficial tissues; giving rise to secondary photons which dominated the effective dose for Incident energies less than 100 keV. Adipose tissue impact on the effective dose was a 25% reduction at the anterior-posterior incidence ranging to a 10% increase at the lateral incidences. Organ dose impacts were more distinctive; symmetrically situated organs demonstrated a 15% reduction at the anterior-posterior Incidence ranging to a 2% increase at the lateral incidences. Abdominal or asymmetrically situated organs demonstrated a 50% reduction at the anterior-posterior incidence ranging to a 25% increase at the lateral incidences.

  9. An evaluation of low-energy x-ray and cobalt-60 irradiations of MOS transistors

    International Nuclear Information System (INIS)

    Dozier, C.M.; Fleetwood, D.M.

    1987-01-01

    An evaluation of methodologies for irradiating MOS transistors with low-energy x-ray and Co-60 sources has been performed. The authors find that comparisons of voltage shifts produced by bulk trapped charge and interface states in MOS transistors irradiated using two different low energy x-ray sources (an ARACOR 10 keV W source and an 8 keV Cu source) agree to within better than 30 percent. This quality of agreement is similar in magnitude to that between MOS devices irradiated by different Co-60 sources. In contrast, the measurements indicate that interlaboratory comparisons of ratios of shifts produced by x-ray and Co-60 sources can lead to differences in ratios as large as a factor of --1.7. Improved electron-hole recombination data for oxides is presented. This recombination correction, in conjunction with a correction for interface dose enhancement, is used to predict the ratios of shifts produced by x-ray and Co-60 sources. However, the results show that corrections for electron-hole recombination and interface does enhancement do not, by themselves, adequately predict the field dependent behavior of these transistors

  10. In vivo transcriptome modulation after low dose of high energy neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Amendola, R; Fratini, E; Piscitelli, M; Sallustio, D E [ENEA, BAS BIOTEC MED, Roma (Italy); Angelone, M; Pillon, M [ENEA, FUS TEC, Frascati (Italy); Chiani, F; Licursi, V; Negri, R [Universita La Sapienza, Roma (Italy). Dip. Biologia Cellulare e dello Sviluppo

    2007-07-01

    Complete text of publication follows. Objective: This project aims to the identification of an hypothetical transcriptome modulation of mouse peripheral blood lymphocytes and skin after exposure to high energy neutron in vivo. Positive candidate genes isolated from mice in in vivo experiments will be selected and evaluated for both radioprotection issues dealing with cosmic ray exposure, and for biomedical issues mainly for low doses and non-cancer effects. Methods: High energy neutron irradiation is performed at the ENEA Frascati, neutron generator facilities (FNG), specifically dedicated to biological samples. FNG is a linear electrostatic accelerator that produces up to 1.0 x 10{sup 11} n/s 14 MeV neutrons via the D-T nuclear reaction. The dose-rate applied for this study is of 0.7 cGy/min. The functional genomic approach has been performed on six animals for each experimental points: un-irradiated; 20 cGy, 6 hours and 24 hours delayed time after exposure. Preliminarily, a pool of total RNA is evaluated on commercial micro-arrays containing large collections of mus musculus cDNAs. Statistical filtering and functional clustering of the data is carried out using dedicated software packages. Results: Candidate genes are selected on the basis of responsiveness to 20 cGy of exposure, with a defined temporal regulation. We plan to organize a systematic screen focused on genes responding to our selection criteria, in in vivo mouse experiments, and correlate their differential expression to the human counterparts. A specific cross species database will be created with all the functional information available in standardized format (MIAME: minimal information about micro-arrays experiments). Conclusions: A lack of information on in vivo experiments is still evident for low doses exposure, especially for neutron of cosmic interest. Individual susceptibility, extensive number of animals to be processed, lack of standardization methodologies are among problems to be solved

  11. Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    McMullan, G., E-mail: gm2@mrc-lmb.cam.ac.uk [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH (United Kingdom); Faruqi, A.R. [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH (United Kingdom); Clare, D. [Crystallography and Institute of Structural and Molecular Biology, Birkbeck College, University of London, Malet Street, London WC1E 7HX (United Kingdom); Henderson, R. [MRC Laboratory of Molecular Biology, Francis Crick Avenue, Cambridge CB2 0QH (United Kingdom)

    2014-12-15

    Low dose electron imaging applications such as electron cryo-microscopy are now benefitting from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three detectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. - Highlights: • Three direct electron detectors offer better DQE than film at 300 keV. • Recorded 300 keV electron events on the detectors have very similar Landau distributions. • The Gatan K2 Summit detector has the highest DQE at low spatial frequency. • The FEI Falcon II detector has the highest DQE beyond one half the Nyquist frequency. • The Direct Electron DE-20 detector has the fastest data acquisition rate.

  12. Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

    International Nuclear Information System (INIS)

    McMullan, G.; Faruqi, A.R.; Clare, D.; Henderson, R.

    2014-01-01

    Low dose electron imaging applications such as electron cryo-microscopy are now benefitting from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three detectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. - Highlights: • Three direct electron detectors offer better DQE than film at 300 keV. • Recorded 300 keV electron events on the detectors have very similar Landau distributions. • The Gatan K2 Summit detector has the highest DQE at low spatial frequency. • The FEI Falcon II detector has the highest DQE beyond one half the Nyquist frequency. • The Direct Electron DE-20 detector has the fastest data acquisition rate

  13. Dose-effect relationship of apoptosis induced by fission-neutron in murine thymocytes

    International Nuclear Information System (INIS)

    Yuan Bin; Li Liang; Xue Wencheng; Sun Jianmin; Wang Baoqin

    2000-01-01

    Objective: To investigate the effectiveness of high LET fission-neutron to induce apoptosis in murine thymocytes and to compare it with that of low LET 60 Co γ-ray. Methods: Apoptosis induction was studied qualitatively by light and transmission electron microscopy and DNA gel electrophoresis,also quantitatively by flow cytometry(FCM) and diphenylamine (DPA)methods. Results: DNA ladders of murine thymocytes were detectable, the typical apoptosis of thymocytes could be observed morphologically by means of light and electron microscopy at 6 h after fission-neutron irradiation with doses ranging from 0.5 to 5.0 Gy, meanwhile the percentages of apoptosis increased with increasing doses. After exposure to γ-rays with doses ranging from 1.0 to 30 Gy, the experimental results were similar to those from neutron radiation. The incidence of apoptosis peaked at about 20 Gy, the percentages did not increase further when doses increased. Conclusion: Apoptosis of murine thymocytes can be induced when mice are exposed to either fission-neutron (0.5-5.0 Gy) or to γ-ray (1-30 Gy). Although the relationship between apoptosis and radiation doses is similar, the percentage of apoptosis induced by neutron irradiation is higher than that induced by γ-irradiation. The RBE values of fission-neutron for inducing apoptosis murine thymocytes are 2.09 (by FCM method) and 2.37 (by DPA method), respectively. These results also suggest that fission-neutron-induced murine immune tissue is more severe than that induced by γ-rays at several hours post-irradiation and this might be the basis for heavy damage to immune tissues induced by fission-neutron-irradiation in later period

  14. Study on the keV neutron capture reaction in {sup 56}Fe and {sup 57}Fe

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Taofeng [Beihang University, International Research Center for Nuclei and Particles in the Cosmos, Beijing (China); Beihang University, School of Physics and Nuclear Energy Engineering, Beijing (China); Lee, Manwoo [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Dong-nam Inst. of Radiological and Medical Sciences, Research Center, Busan (Korea, Republic of); Kim, Guinyun [Kyungpook National University, Department of Physics, Daegu (Korea, Republic of); Ro, Tae-Ik [Dong-A University, Department of Physics, Busan (Korea, Republic of); Kang, Yeong-Rok [Dong-A University, Department of Physics, Busan (Korea, Republic of); Dong-nam Inst. of Radiological and Medical Sciences, Research Center, Busan (Korea, Republic of); Igashira, Masayuki; Katabuchi, Tatsuya [Tokyo Institute of Technology, Research Laboratory for Nuclear Reactors, Tokyo (Japan)

    2014-03-15

    The neutron capture cross-sections and the radiative capture gamma-ray spectra from the broad resonances of {sup 56}Fe and {sup 57}Fe in the neutron energy range from 10 to 90 keV and 550 keV have been measured with an anti-Compton NaI(Tl) detector. Pulsed keV neutrons were produced from the {sup 7}Li (p,n) {sup 7}Be reaction by bombarding the lithium target with the 1.5ns bunched proton beam from the 3MV Pelletron accelerator. The incident neutron spectrum on a capture sample was measured by means of a time-of-flight (TOF) method with a {sup 6}Li -glass detector. The number of weighted capture counts of the iron or gold sample was obtained by applying a pulse height weighting technique to the corresponding capture gamma-ray pulse height spectrum. The neutron capture gamma-ray spectra were obtained by unfolding the observed capture gamma-ray pulse height spectra. To achieve further understanding on the mechanism of neutron radiative capture reaction and study on physics models, theoretical calculations of the γ-ray spectra for {sup 56}Fe and {sup 57}Fe with the POD program have been performed by applying the Hauser-Feshbach statistical model. The dominant ingredients to perform the statistical calculation were the Optical Model Potential (OMP), the level densities described by the Mengoni-Nakajima approach, and the γ-ray transmission coefficients described by γ-ray strength functions. The comparison of the theoretical calculations, performed only for the 550keV point, show a good agreement with the present experimental results. (orig.)

  15. Effects of long-term, low dose rate fission neutron irradiation on the peripheral hematological cells in rats

    International Nuclear Information System (INIS)

    Jiang Dingwen; Lei Chengxiang; Shen Xianrong; Ma Li; Yang Xufang; Peng Wulin; Dai Shourong

    2008-01-01

    Objective: To evaluate the effects of long-term, low dose rate fission neutron irradiation on the peripheral hematological cells in rats. Methods: 96 rats were randomly divided into the control group and the irradiation group with low dose rate fission neutron ( 252 Cf, 0.35 mGy/h) irradiation 20.5 h every day. 8 rats of each group were killed at 14 d, 28 d, 42d, 56d, 70d after irradiation and 35d after the irradiation, and their peripheral hematological cells were tested respectively. Results: Compared with the control group, peripheral blood WBC was reduced significantly at the dose of 0.3Gy and 0.4Gy (P < 0.05), and was reduced remarkably at dose of 0.5Gy (P<0.01) and 35d after stopping irradiation(P<0.01). At dose of 0.2Gy, Peripheral blood RBC was abnormally higher comparing with the control group (P<0.01), accompanying with higher HCT and HGB, which suggests condensed blood. At the other point, RBC tend to become lower, but only at dose 0.5Gy, and the difference is significant comparing with control group(P <0.05). At dose of 0.3Gy, 0.4Gy and 0.5Gy, HCT were significantly lower comparing with control group. Comparing with control group, MCV was higher at 35d after stopping irradiation, and PLT was significantly lower in dose of 0.2Gy. Conclusion: Long-term irradiation with low dose rate fission neutron could significantly reduce peripheral blood WBC, with less effects on RBC and PLT. The reduced WBC could not recover at 35d after stopping irradiation. (authors)

  16. Life shortening, tumor induction, and tissue dose for fission-neutron and gamma-ray irradiations

    International Nuclear Information System (INIS)

    Grahn, D.; Duggal, K.; Lombard, L.S.

    1985-01-01

    The primary focus of this program is to obtain information on the late effects of whole body exposure to low doses of a high linear-energy-transfer (LET) and a low-LET ionizing radiation in experimental animals to provide guidance for the prediction of radiation hazards to man. The information obtained takes the form of dose-response curves for life shortening and for the induction of numerous specific types of tumors. The animals are irradiated with fission neutrons from the Janus reactor and with 60 Co gamma rays, delivered as single, weekly, or duration-of-life exposures covering the range of doses and dose rates. 6 refs

  17. Effect of pulsed dose in simultaneous and sequential irradiation of V-79 cells by 14.8-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Gould, M.N.

    1984-01-01

    The effect of irradiating V-79 Chinese hamster cells with a mixture of 40% 14.8-MeV neutrons and 60% 69 Co photons with simultaneous or sequential exposures is investigated. Sample doses are obtained by irradiating cells with alternating 3-min pulses of neutrons and photons (in the sequential case) or with mixed neutrons and photons followed by equal beam-off periods to ensure equal total exposure times for sequential and simultaneous irradiations. Differences between the survival results under each beam configuration that are consistent with previous observations with nonpulsed irradiations are observed

  18. DIANE, a simulation code for the interaction of neutrons with living tissues. Application to low doses of fast neutrons on human tumoral cells; DIANE, un code de simulation de l'interaction des neutrons avec la matiere vivante. Applications aux faibles doses de neutrons rapides sur des cellules tumorales humaines

    Energy Technology Data Exchange (ETDEWEB)

    Nenot, M.L

    2003-07-15

    Our work deals with the irradiation of cells and living tissues by 14 MeV neutrons at very low doses (a few 10{sup -2} Gy). Such experiments require an accurate knowledge of the values of neutron dose rates and fluences at the level of cell cultures. We have performed measurements of fluence rates through an activation method applied to gold and copper foils. The fluence rate is deduced from the gamma rays emitted by the irradiated foils. Neutron doses and dose rates have been measured through varied methods: PIN diodes, ionization tissue equivalent chambers, and Geiger-Mueller counters. We have designed the DIANE code to simulate the impact of energetic neutrons on cells. This code can be used with isolated cells or macroscopic tissues, it takes into account the roles of the ionisation electrons produced by recoil nuclei entering the cell. This point is all the more important since recent works have highlighted the impact of very low energy electrons on DNA. (A.C.)

  19. Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV.

    Science.gov (United States)

    Maigne, L; Perrot, Y; Schaart, D R; Donnarieix, D; Breton, V

    2011-02-07

    The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.

  20. Effects of low dose rate fission neutron irradiation on the lymphocyte subpopulations of peripheral blood in rats

    International Nuclear Information System (INIS)

    Jiang Dingwen; Lei Chengxiang; Shen Xianrong; Ma Li; Yang Yifang; Peng Wulin; Dai Shourong

    2008-01-01

    Objective: To evaluate the effects of long-term, low dose rate fission neutron irradiation on lymphocyte subpopulations in peripheral blood of rats. Methods: Ninety-six rats were randomly divided into control group and irradiated group exposed to low dose rate fission neutron ( 252 Cf,0.35 mGy/h) for 20.5 h every day. At days 14,28,42,56 and 70 d after irradiation and 35 d after stopping irradiation, After 8 rats of each group were killed, WBC and lymphocyte subpopulations of CD4 + CD3 + , CD8 + CD3 + and CD45RA + /CD161α + in peripheral blood were estimated respectively. Results: Compared with the control group, WBC was reduced significantly at dose of 0.3, 0.4 and 0.5 Gy (P + CD3 - was evidently higher compared with control group at doses of 0.1,0.3, 0.4 and 0.5 Gy and 35 d after stopping irradiation (P + CD3 - was obviously higher compared with control group at dose of 0.2 and 0.3 Gy (P + CD3 + at dose of 0.1 Gy (P + CD3 + at doses of 0.1 and 0.2 Gy (P + CD45RA - ) was increased significantly at doses of 0.2-0.3 Gy, and peripheral blood B cells(CD161α - CD45RA + ) was reduced remarkably at doses of 0.1-0.5 Gy and 35 d after stopping irradiation compared with the control group. Conclusions: Long-term irradiation with low dose rate fission neutron could make TCR (T-cell-receptor) mutant, therefore, WBC, B cells in peripheral blood significantly reduced and NK cells increased. These changes may could not recover at 35 d after Stopping irradiation. (authors)

  1. Effect of low level doses of fast neutrons on the activity of the snake venom

    International Nuclear Information System (INIS)

    Hanafy, Magda S.; Amin, Aida M.

    1998-01-01

    In this work, the effect of low level doses of fast neutrons from 252 Cf on snake venom (Cerastes cerastes) was studied through measurements of biophysical and haematological changes. The absorption spectrum (200-700 nm) of haemoglobin (Hb) collected from the blood of rats after 3 and 24 hours post injection with irradiated and non-irradiated snake venom with neutron fluences of 3x10 6 , 2.8x10 7 and 3X10 8 n/cm 2 was measured. The results indicated that injection of animals with either non- irradiated or irradiated venom ( with different neutron fluences) resulted into the decrease of the absorption band intensities of Hb. These changes in the properties of the characteristic band showed to be a marker for irradiated venom and is dose dependent. It was concluded that neutron irradiation of the venom leads to the decrease of its toxicity and, consequently, to the increase of the chance of repair mechanism in livings. Obvious changes of most haematological erythrocytic values of Hb, packed cell volume (PCV), red blood counts (RBC), mean corpuscular volume (MCV), mean corpuscular haemoglobin (MCHb) and mean corpuscular haemoglobin concentration (MCHC) were observed in the blood of the rats injected with non-irradiated venom (as a first group) and those injected with the irradiated venom (as a second group). The microcytic haemolytic anemia was more acute in the first group than in the second one which showed lesser extent. It is concluded from this study that low level doses of fast neutrons could postpone and lower acute haematological action induced by the venom. (authors)

  2. Determination of the absorbed dose and dose-distribution in water for low- and medium-energetic photons

    International Nuclear Information System (INIS)

    Bultman, J.H.

    1990-05-01

    The methods to determine the absorbed dose to water for low and medium energy photons were studied. Large differences between the results of these methods exists. So, a research proposition has been made to explain these differences. The goal of this research will be the development of a method to determine the absorbed dose below approximately 400 keV with an ionization chamber calibrated at 60 Co gamma radiation. To explain the differences between the set of methods, some causes were proposed, like the influence of the ionisation chamber on the measurement in water. Also, some methods to determine the factors are proposed. (author). 29 refs

  3. Neutron Cross section Covariances in the Resonance region: 50,53Cr, 54,57Fe and 60Ni

    Energy Technology Data Exchange (ETDEWEB)

    Oblozinsky, P.; Cho,Y.-S.; Mattoon,C.M.; Mughabghab,S.F.

    2010-11-23

    We evaluated covariances in the neutron resonance region for capture and elastic scattering cross sections on minor structural materials, {sup 50,53}Cr, {sup 54,57}Fe and {sup 60}Ni. Use was made of the recently developed covariance formalism based on kernel approximation along with data in the Atlas of Neutron Resonances. Our results of most interest for advanced fuel cycle applications, elastic scattering cross section uncertainties at energies around 100 keV, are on the level of about 7-10%.

  4. The neutron and low-energy gamma operational dosimetry in Melox plant

    International Nuclear Information System (INIS)

    Devita, A.D.

    2006-01-01

    M.E.L.O.X., subsidiary of A.R.E.V.A., produce M.O.X. fuels, a mixture of uranium and plutonium oxides. With the use in the process of plutonium oxide, there is a risk of external exposure to neutrons and low -energy gamma rays. By their characteristics, both these types of radiation are difficult to measure. The difficulty in measuring neutron doses lies in the fact that the fluence -to-dose equivalent conversion factor varies with the neutron energy level. In low -energy gamma (between 20 and 60 keV) dose measurement, the problem is detection using an electronic system. Just some years ago, very few industrial players were tempted to develop dosimeters in these areas in view of the poor demand and market prospects. Furthermore, radiation protection specialists needed a highly functional and robust direct reading dosimeters or, in other words, a device that was simple, reliable, inexpensive, small, and quick and easy to use in a wide range of working environments that could vary in terms of both the workstation and external exposure. In addition, at sites such as Melox, where company employees work alongside personnel from outside companies, the same types of dosimeters must be used so that dose -related data can be managed globally in one data base. Two technical solutions are available for neutron operational dosimetry - spectrometer-dosimeters and calibration dosimeters. Melox has opted for the use of calibration dosimeters. The reasons for this choice (technical, financial and organizational criteria) are given in this presentation. Before and during the various campaigns of M.O.X. fuels, the spectral characteristics relating to neutron fluence at different workstations and representative of personnel exposure levels were determined. A reference spectrometer was then used to determine the transfer function between fluence and dose in order to calibrate passive and operational dosimeters appropriately.The methodology to be set up should guarantee good

  5. Relative biological efficiency of intermediate energy neutrons and 60Co rays for induction of chromosomal aberrations in Chinese hamster fibroblasts

    International Nuclear Information System (INIS)

    Sturelid, S.; Bergman, R.

    1976-01-01

    Intermediate energy neutrons are unique in that a considerable fraction of critical interactions and of dose absorbed is not associated with ionization but with atomic collision. It is still unknown to what extent the qualitative difference in primary damage after atomic collision compared to that of ionization and excitation becomes expressed at biological levels. Chromosomal aberrations were studied in Chinese hamster fibroblasts exposed for 5-8 hours at 22 degree C to intermediate energy neutrons, mean energy 8.5 keV, or to 60 Co-gamma rays. RBE at the 10 per cent aberration frequency level in S-phase were 2.2+-0.6 for total aberrations, 2.1+-0.6 for chromatid breaks and 1.8+-0.5 for exchanges. For each chromatid aberration observed after recovery, about 200 bondbreaking atomic collisions besides 3000 primary iniozations should have occured in DNA. However, the extent to which the aberration response is due to atomic collisions is not clear. (author)

  6. A new approach for precise measurements of keV neutron capture cross sections: The examples of 93Nb, 103Rh, and 181Ta

    International Nuclear Information System (INIS)

    Wisshak, K.; Voss, F.; Kaeppeler, F.; Reffo, G.

    1990-04-01

    A new experimental method has been implemented for precise measurements of neutron capture cross sections in the energy range from 3 to 200 keV. Neutrons are produced via the 7 Li(p,n) 7 Be reaction using a pulsed 3 MV Van de Graaff accelerator. The neutron energy is determined by the time of flight technique using flight paths of less than 1 m. Capture events are detected with the Karlsruhe 4π Barium Fluoride Detector. This detector is characterized by a resolution in gamma-ray energy of 14% at 662 keV and 7% at 2.5 MeV, a time resolution of 500 ps, and a peak efficiency of 90% at 1 MeV. Capture events are registered with ≅ 95% probability above a gamma-ray threshold of 2.5 MeV. The combined effect of the relatively short primary flight path, the 10 cm inner radius of the detector sphere, and of the low capture cross section of BaF 2 allows to discriminate the main background due to capture of sample scattered neutrons in the scintillator via time of flight, leaving part of the neutron energy range completely undisturbed. The high efficiency and good energy resolution for capture gamma-rays yields a further reduction of this background by using only the relevant energy channels for data evaluation. In the first measurements with the new detector, the neutron capture cross sections of 93 Nb, 103 Rh, and 181 Ta were determined in the energy range from 3 to 200 keV relative to gold as a standard. The cross section ratios could be determined with overall systematic uncertainties of 0.7 to 0.8%; statistical uncertainties were less than 1% in the energy range from 20 to 100 keV, if the data are combined in 20 keV wide bins. The necessary sample masses were of the order of one gram. Further improvements with respect to sensitivity and accuracy are discussed. (orig.) [de

  7. Patterns of Lethality and Absorbed Dose Distributions in Mice for Monoenergetic Neutrons; Letalite et Distribution de la Dose Absorbee chez la Souris pour des Neutrons Monoenergetiques; Letal'nost' i raspredelenie pogloshchennoj dozy pri obluchenii myshej monoehnergeticheskimi neitronami; Letalidad y Distribucion de las Dosis Absorbidas por el Raton para Neutrones Monoenergeticos

    Energy Technology Data Exchange (ETDEWEB)

    Frigerio, N. A.; Jordan, D. L. [Argonne National Laboratory, Argonne, IL (United States)

    1964-03-15

    The presence of strong C, N and O resonances in the 100 to 1500 keV region has permitted the study of specific neutron-nuclide interactions as reflected in lethality, RBE maxima etc. Sixty-two {mu}A of resolved Van de Graaf protons, 1882 to 2738 keV, yielded monoenergetic neutrons via Li{sup 7}(p, n)Be{sup 7}. Virgin female CF-1 mice were exposed in celluloid capsules to the mono-energetic neutrons at distances of 3.1 to 11.3 cm from the source at laboratory angles of 0 to 1 radian. Mice were exposed bilaterally while simultaneously in motion through either circular or elliptical orbits normal to the axis of the beam. Thus, control of dose distribution within the animal was possible. Absolute flux measurements were made with U{sup 235} fission counters and by absolute counting of Au wires and foils activated within Cd covers. Patterns of dose absorption were measured with micro-ionization chambers and with a specially developed FeSO{sub 4}-NH{sub 4}SCN dosimeter of high sensitivity. Relative dose measurements were made with Hurst proton-recoil gas counters and B{sup 10} , Li{sup 6} and proton-recoil scintillators. Neutron-energy distributions were measured with specially developed B{sup 10}, He{sup 3} and Li{sup 6} gas and solid-state spectrometers. Gamma contributions were measured with Ne/Ar chamber counters. These measurements showed gamma contribution to be less than 0.8%, and thermal-epithermal less than 0.01%, of the total rad dose. Animals were exposed to median midpoint doses ranging from 180 to 1200 rad at neutron energies from 396 to 658 keV {+-} 50 keV to cover the region of N and O resonances. Levels and patterns of lethality proved to be strong functions of neutron energy and equally strong, but independent, functions of dose distribution. Regardless of dose, energy or distribution, however, all animals surviving five days survived at least 144 days, dying then of the usual long-term effects. This suggests that monoenergetic fast neutrons, free of

  8. Does fast-neutron radiotherapy merely reduce the radiation dose

    International Nuclear Information System (INIS)

    Ando, Koichi

    1984-01-01

    We examined whether fast-neutron radiotherapy is superior to low-LET radiotherpy by comparing the relationship between cell survival and tumor control probabilities after exposure of tumor-bearing (species) to the two modalities. Analysis based on TCD 50 assay and lung colony assay indicated that single dose of fast neutron achieved animal cures at higher survival rates than other radiation modalities including single and fractionated γ-ray doses, fractionated doses of fast neutron, and the mixed-beam scheme with a sequence of N-γ-γ-γ-N. We conclude that fast-neutron radiotherapy cured animal tumors with lower cell killing rates other radiation modalities. (author)

  9. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  10. Study on neutron capture cross sections using the filtered neutron beams of 55 keV and 144 keV at the Dalat reactor and related applications

    International Nuclear Information System (INIS)

    Vuong Huu Tan; Nguyen Canh Hai; Pham Ngoc Son; Tran Tuan Anh

    2007-01-01

    In this fundamental research project on nuclear physics in period of 2006, the neutron capture cross sections for the reactions of 139 La (n,γ) 140 La, 152 Sm (n,γ) 153 Sm, 191 Ir (n,γ) 192 Ir and 193 Ir (n,γ) 194 Ir have been measured at 55 keV and 144 keV by the activation method using the filtered neutron beams of the Dalat nuclear research reactor. The cross sections were determined relative to the standard capture cross sections of 197 Au. The samples and standard were prepaid from high purity (99.99%) foil of Au and natural oxide powders of La 2 O 3 , Sm 2 O 3 and IrO 2 . A high efficient HPGe detector (58%) was used to detect the gamma rays, emitted from the activated samples. The absolute efficiency curve of the detector has been precisely calibrated thanks to a set of standard radioisotope sources and a multi-nuclide standard solution, supported by IAEA. The present results were compared with the previous measurements from EXFOR-2003, and the evaluated values of JENDL 3.3 and ENDF/B-6.8. (author)

  11. Comparison of the effects of 50 MeV/sub d → Be/ neutron and cobalt-60 irradiation of the kidneys of Rhesus monkeys

    International Nuclear Information System (INIS)

    Raulston, G.L.; Gray, K.N.; Gleiser, C.A.; Jardine, J.H.; Flow, B.L.; Huchton, J.I.; Bennett, K.R.; Hussey, D.H.

    1978-01-01

    Twenty rhesus monkeys had one kidney irradiated (after undergoing unilateral nephrectomies) with one of four doses: 960 or 1080 rads of 50 MeV/sub d→Be/ neutrons, or 2350 or 2700 rads of 60 Co. Whereas animals treated with the lower dose of neutrons or 60 Co are alive with relatively normal renal function, those treated with the higher dose of neutrons died of radiation nephritis. Animals treated with the higher dose of 60 Co developed radiation nephritis but survived. The physiological and histopathological changes of radiation nephritis secondary to neutron irradiation are not qualitatively different from those reported for radiation nephritis secondary to photon irradiation

  12. Atlas of neutron resonances

    CERN Document Server

    Mughabghab, Said

    2018-01-01

    Atlas of Neutron Resonances: Resonance Properties and Thermal Cross Sections Z= 1-60, Sixth Edition, contains an extensive list of detailed individual neutron resonance parameters for Z=1-60, as well as thermal cross sections, capture resonance integrals, average resonance parameters and a short survey of the physics of thermal and resonance neutrons. The long introduction contains: nuclear physics formulas aimed at neutron physicists; topics of special interest such as valence neutron capture, nuclear level density parameters, and s-, p-, and d-wave neutron strength functions; and various comparisons of measured quantities with the predictions of nuclear models, such as the optical model. As in the last edition, additional features have been added to appeal to a wider spectrum of users. These include: spin-dependent scattering lengths that are of interest to solid-state physicists, nuclear physicists and neutron evaluators; calculated and measured Maxwellian average 5-keV and 30-keV capture cross sections o...

  13. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  14. Fast neutron personnel dosimetry by CR-39 plastics a new electrochemical etching procedure

    International Nuclear Information System (INIS)

    Djeffal, S.

    1984-07-01

    In the first part of this work a brief description of solid state nuclear track detectors, the principles of track registration and the different reading techniques are given. In the experimental part of the present work we systematically analysed different etching procedures and set a new electrochemical etching method, which enables us to develop a new fast neutron dosimeter. This fast neutron dosimeter makes possible the measurement of low neutron doses in the energy range from 10 Kev to 20 Mev with a reasonably flat energy response. These new developments are very attractive in personnel neutron dosimetry where nuclear emulsions are still used despite their insensitivity to neutron energies down to 500 Kev (i.e. the energy range one often encounters around nuclear facilities)

  15. Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL

    International Nuclear Information System (INIS)

    Radev, R.

    2009-01-01

    In June 2007, 10 CFR 835 (1) was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 (2). The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring (3,4,5) including the ambient dose equivalent H*(d) to be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of ±25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The

  16. Relative biological effectiveness (R.B.E.) of Cf-252 vs. acute Co-60 and low dose rate Cs-137 irradiation by spleen weight loss

    International Nuclear Information System (INIS)

    Maruyama, Y.; Feola, J.M.; Magura, C.; Beach, J.L.

    1986-01-01

    R.B.E. of Cf-252 on lymphoid tissue was assessed by radiation study of spleen weight loss following acute Co-60, and low dose rate (L.D.R.) Cs-137 and Cf-252 irradiations. Acute Co-60 and L.D.R. Cs-137 dose-response followed two component exponential curves with a 1.3-fold greater effect of L.D.R. Cs-137 vs. acute Co-60 on the first slope and 1.9-fold greater effect for the 2nd slope. L.D.R. Cf-252 response was 1.3 x greater than acute Co-60 but was 1.0 vs. L.D.R. Cs-137 for the first slope indicating a similar effect of Cf-252 mixed neutron/gamma radiation to L.D.R. gamma radiation in producing spleen shrinkage. There was no effect of different sequences and schedules of mixing acute Co-60 with Cf-252 irradiation observed by endogenous CFU-S survival. The R.B.E. of 1.0 - 1.9 indicates that lymphohemopoietic in vivo, presumably well oxygenated, does not respond acutely or as sensitively as hypoxic tumor where R.B.E. is 5 - 7. (author)

  17. High neutronic efficiency, low current targets for accelerator-based BNCT applications

    International Nuclear Information System (INIS)

    Powell, J.R.; Ludewig, H.; Todosow, M.

    1998-01-01

    The neutronic efficiency of target/filters for accelerator-based BNCT applications is measured by the proton current required to achieve a desirable neutron current at the treatment port (10 9 n/cm 2 /s). In this paper the authors describe two possible targeyt/filter concepts wihch minimize the required current. Both concepts are based on the Li-7 (p,n)Be-7 reaction. Targets that operate near the threshold energy generate neutrons that are close tothe desired energy for BNCT treatment. Thus, the filter can be extremely thin (∼ 5 cm iron). However, this approach has an extremely low neutron yield (n/p ∼ 1.0(-6)), thus requiring a high proton current. The proposed solutino is to design a target consisting of multiple extremely thin targets (proton energy loss per target ∼ 10 keV), and re-accelerate the protons between each target. Targets operating at ihgher proton energies (∼ 2.5 MeV) have a much higher yield (n/p ∼ 1.0(-4)). However, at these energies the maximum neutron energy is approximately 800 keV, and thus a neutron filter is required to degrade the average neutron energy to the range of interest for BNCT (10--20 keV). A neutron filter consisting of fluorine compounds and iron has been investigated for this case. Typically a proton current of approximately 5 mA is required to generate the desired neutron current at the treatment port. The efficiency of these filter designs can be further increased by incorporating neutron reflectors that are co-axial with the neutron source. These reflectors are made of materials which have high scattering cross sections in the range 0.1--1.0 MeV

  18. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  19. Study on the neutron dosimetric characteristics of Tissue Equivalent Proportional Counter

    Energy Technology Data Exchange (ETDEWEB)

    Nunomiya, T.; Kim, E.; Kurosawa, T.; Taniguchi, S.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Tsujimura, N.; Momose, T.; Shinohara, K. [Japan Nuclear Cycle Development Inst., Environment and Safety Division, Tokai Works, Tokai, Ibaraki (Japan)

    1999-03-01

    The neutron dosimetric characteristics of TEPC (Tissue Equivalent Proportional Counter) has been investigated under a cooperative study between Tohoku University and JNC since 1997. This TEPC is a spherical, large volume, single-wire proportional counter (the model LETSW-5, manufactured by Far West Technology, Inc.) and filled with a tissue equivalent gas in a spherical detector of the A-150 tissue equivalent plastic. The TEPC can measure the spectra of absorbed dose in LET and easily estimate the tissue equivalent dose to neutron. This report summarizes the dosimetric characteristics of TEPC to the monoenergetic neutrons with energy from 8 keV to 15 MeV. It is found that TEPC can estimate the ambient dose equivalent, H*(10), with an accuracy from 0.9 to 2 to the neutron above 0.25 MeV and TEPC has a good counting efficiency enough to measure neutron doses with low dose rate at the stray neutron fields. (author)

  20. Neutron Capture Gamma Ray Cross Sections for Ta, Ag, In and Au between 30 and 175 keV

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, J; Beshai, S

    1971-11-15

    A new detector has been used to determine neutron capture gamma ray cross sections for Ta, Ag, In and Au. The results are listed and discussed together with associated problems. The energy range from 30 keV to 175 keV is considered

  1. Neutron Capture Gamma Ray Cross Sections for Ta, Ag, In and Au between 30 and 175 keV

    International Nuclear Information System (INIS)

    Hellstroem, J.; Beshai, S.

    1971-11-01

    A new detector has been used to determine neutron capture gamma ray cross sections for Ta, Ag, In and Au. The results are listed and discussed together with associated problems. The energy range from 30 keV to 175 keV is considered

  2. Measurement of the relationship of 24 Na activity and the received neutron dose

    International Nuclear Information System (INIS)

    Gossio, S.; Carrelli, J.; Villella, A.; Soppe, E.

    2013-01-01

    In cases of criticality accidents it is required a fast dosimetric system that allows to evaluate the doses of the personnel involved. The reaction (n,y) with sodium presented in the body ( 23 Na), generates 24 Na, that emits two gamma of 1369KeV and 2754 KeV that can be measured using a whole body counter. The experienced were carried out with the irradiation of 252 Cf of a phantom with a solution of NaCl in water. After the irradiation it was measured the 24 Na activity in the whole body counter, which has a HPGe detector previously calibrated in energy and efficiency. Considering the correction by decay, the quantity of 23 Na presented in the body of an adult and elimination curve of 24 Na, it was established a coefficient of neutronic doses by unity of activity of 24 Na measured in the whole body counter. This method is useful for the retrospective estimation of the doses, as well as to carry out a radiological sorting in case of criticality

  3. Micronuclei induced by fast neutrons versus 60Co gamma-rays in human peripheral blood lymphocytes.

    Science.gov (United States)

    Vral, A; Verhaegen, F; Thierens, H; De Ridder, L

    1994-03-01

    Here we compared the effectiveness of neutrons ( = 5.5 MeV) versus 60Co gamma-rays in producing micronuclei (MN) in human lymphocytes. To obtain dose-response data, blood samples of six donors were irradiated with doses ranging from 0.1 to 5 Gy for gamma-rays and 0.1-3 Gy for neutrons. A linear dependence of MN yield with dose was found for fast neutrons while for gamma-rays a nonlinear dependence existed. For both radiation qualities no significant interindividual differences were found. Derived relative biological effectiveness values decreased with increasing dose. The MN frequency distributions were overdispersed with respect to the Poisson distribution, with neutrons showing higher dispersion values than with gamma-rays. To compare the repair kinetics of both radiation qualities split-dose experiments were performed. A dose of 4 Gy gamma-rays (3 Gy neutrons) was delivered either as a single exposure or in two equal fractions separated by time intervals ranging from 30 min to 10 h (30 min to 7 h for neutrons). The data showed for gamma-rays a significant decline (30% +/- 10%) in MN yield with interfraction time due to repair of DNA damage. This repair is a continuous process starting almost immediately after the first of the two doses and lasting 3-5 h. For fast neutrons no decline was observed indicating irreparable damage.

  4. Monte Carlo simulations of the secondary neutron ambient and effective dose equivalent rates from surface to suborbital altitudes and low Earth orbit.

    Science.gov (United States)

    El-Jaby, Samy; Richardson, Richard B

    2015-07-01

    Occupational exposures from ionizing radiation are currently regulated for airline travel (Earth orbit (∼300-400 km). Aircrew typically receive between 1 and 6 mSv of occupational dose annually, while aboard the International Space Station, the area radiation dose equivalent measured over just 168 days was 106 mSv at solar minimum conditions. It is anticipated that space tourism vehicles will reach suborbital altitudes of approximately 100 km and, therefore, the annual occupational dose to flight crew during repeated transits is expected to fall somewhere between those observed for aircrew and astronauts. Unfortunately, measurements of the radiation environment at the high altitudes reached by suborbital vehicles are sparse, and modelling efforts have been similarly limited. In this paper, preliminary MCNPX radiation transport code simulations are developed of the secondary neutron flux profile in air from surface altitudes up to low Earth orbit at solar minimum conditions and excluding the effects of spacecraft shielding. These secondary neutrons are produced by galactic cosmic radiation interacting with Earth's atmosphere and are among the sources of radiation that can pose a health risk. Associated estimates of the operational neutron ambient dose equivalent, used for radiation protection purposes, and the neutron effective dose equivalent that is typically used for estimates of stochastic health risks, are provided in air. Simulations show that the neutron radiation dose rates received at suborbital altitudes are comparable to those experienced by aircrew flying at 7 to 14 km. We also show that the total neutron dose rate tails off beyond the Pfotzer maximum on ascension from surface up to low Earth orbit. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  5. Formation of low friction and wear-resistant carbon coatings on tool steel by 75keV, high-dose carbon ion implantation

    International Nuclear Information System (INIS)

    Mikkelsen, N.J.; Eskildsen, S.S.; Straede, C.A.; Chechenin, N.G.

    1994-01-01

    Hardened AISI D2 steel samples were subjected to mass-separated C + ion bombardment at 75keV with ion doses in the range 0.5-15x10 18 C + cm -2 . It was observed that sputtering was still limited, and the system exhibited internal growth, because most of the ions penetrated more than 0.1μm into the growing carbon film. At the lowest ion doses applied, carbon was implanted into the steel, while higher doses resulted in the implanted carbon concentration near the surface being almost 100%. For the highest doses applied, Rutherford backscattering spectrometry and surface profilometry analyses showed that layers about 0.5-1μm thick of almost pure carbon grew outward from the steel substrate. Transmission electron microscopy showed that the carbon layers were amorphous and exhibited an intermixed layer-substrate interface. The layers were hard and exhibited pronounced elastic recovery when subjected to ultralow load indentation. Low friction and excellent wear properties were measured when tested under dry conditions with a ball-on-disc tribometer. ((orig.))

  6. Neutron-capture cross-section measurement for 163Dy In the neutron energy range from 15 to 75 keV

    International Nuclear Information System (INIS)

    Kim, Hyun Duk; Jung, Eui Jung; Ahn, Jung Keun; Lee, Dae Won; Kim, Guin Yun; Ro, Tae Ik; Min, Young Ki; Igashira, Masayuki; Ohsaki, Toshiro; Mizuno, Satoshi

    2002-01-01

    The neutron-capture cross-section of 163 Dy were measured in the neutron energy range from 15 to 75 keV at the 3-MV Pelletron accelerator of the Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology. Pulsed neutrons were produced from the 7 Li(p,n) 7 Be reaction by bombarding a metallic lithium target with the 1.903-MeV proton beam. The incident neutron spectra were measured by means of a neutron time-of-flight method with a 6 Li-glass detector. Capture γ-rays were detected with a large anti-Compton NaI(Tl) spectrometer. A pulse-height weighting technique was applied to the capture γ-ray pulse-height spectra to obtain capture yields. The neutron capture cross-section were determined relative to the standard capture cross-sections of 197 Au. The present results were compared with the previous measurements and the evaluated values of ENDF/B-VI

  7. Neutron spectrometry for protection dosimetry at very low levels

    International Nuclear Information System (INIS)

    Bardell, A.G.; Thomas, D.J.

    1996-01-01

    Dose limits for exposure of members of the public are significantly lower than those for designated radiation workers. The new ICRP 60 recommendation for critical groups of the general public is an effective dose limit of 1 mSv per year which requires a measurement capability at levels down to about 100 nSv h - 1. Radiation protection dosimetry for neutrons at these levels is problematical, nevertheless, operators of nuclear sites are still required to demonstrate acceptably low radiation levels in areas accessible to the public. In addition to the known poor dose equivalent response of available dosemeters, there is an added problem at low levels of inadequate sensitivity. Personal dosemeters are certainly not sufficiently sensitive, and the sensitivity of area survey instruments is such that they can only be used in integral mode Even then, the statistical uncertainties are likely to be large. One further problem concerns the quantity measured. Survey instruments are designed to measure the operational quantity ambient dose equivalent, H*(10), which always tends to be an overestimate of the present limiting quantity effective dose equivalent. If in any situation exposure is near the limit, an estimate of H*(10) may not be sufficient to prove conclusively that levels are less than the statutory limit, and a direct estimate of effective dose equivalent may need to be made. The only way of estimating effective dose equivalent is via an absolute spectral measurement. From such a spectrum any relevant dosimetric quantity can be estimated via tabulated fluence to dose equivalent conversion factors. (Certain quantities also require information about the angular dependence of the field - see later text). Spectrometry at such low neutron fluence levels is difficult, however, there is one instrument available which can perform the required measurements, and this is a well characterised Bonner sphere (BS) set. (author)

  8. Thermal conductivity of beryllium under low temperature high dose neutron irradiation

    International Nuclear Information System (INIS)

    Chakin, V.P.; Latypov, R.N.; Suslov, D.N.; Kupriyanov, I.B.

    2004-01-01

    Thermal conductivity of compact beryllium of several Russian grades such as TE-400, TE-56, TE-30, TIP and DIP differing in the production technology, grain size and impurity content has been investigated. The thermal diffusivity of beryllium was measured on the disks in the initial and irradiated conditions using the pulse method in the range from room temperature to 200degC. The thermal conductivity was calculated using the table values for the beryllium thermal capacity. The specimens and beryllium neutron source fragments were irradiation in the SM reactor at 70degC and 200degC to a neutron fluence of (0.5-11.4)·10 22 cm -2 (E>0.1 MeV) and in the BOR-60 reactor at 400degC to 16·10 22 cm -2 (E>0.1MeV), respectively. The low-temperature irradiation leads to the drop decrease of the beryllium thermal conductivity and the effect depends on the irradiation parameters. The paper analyses the effect of irradiation parameters (temperature, neutron fluence), measurement temperature and structural factors on beryllium conductivity. The experiments have revealed that the short time post-irradiation annealing at high temperature results in partial reduction of the thermal conductivity of irradiated beryllium. (author)

  9. Construction of monoenergetic neutron calibration fields using 45Sc(p, n)45Ti reaction at JAEA.

    Science.gov (United States)

    Tanimura, Y; Saegusa, J; Shikaze, Y; Tsutsumi, M; Shimizu, S; Yoshizawa, M

    2007-01-01

    The 8 and 27 keV monoenergetic neutron calibration fields have been developed by using (45)Sc(p, n)(45)Ti reaction. Protons from a 4-MV Pelletron accelerator are used to bombard a thin scandium target evaporated onto a platinum disc. The proton energies are finely adjusted to the resonance to generate the 8 and 27 keV neutrons by applying a high voltage to the target assemblies. The neutron energies were measured using the time-of-flight method with a lithium glass scintillation detector. The neutron fluences at a calibration point located at 50 cm from the target were evaluated using Bonner spheres. A long counter was placed at 2.2 m from the target and at 60 degrees to the direction of the proton beam in order to monitor the fluence at the calibration point. Fluence and dose equivalent rates at the calibration point are sufficient to calibrate many types of the neutron survey metres.

  10. PANDORA, a large volume low-energy neutron detector with real-time neutron-gamma discrimination

    Science.gov (United States)

    Stuhl, L.; Sasano, M.; Yako, K.; Yasuda, J.; Baba, H.; Ota, S.; Uesaka, T.

    2017-09-01

    The PANDORA (Particle Analyzer Neutron Detector Of Real-time Acquisition) system, which was developed for use in inverse kinematics experiments with unstable isotope beams, is a neutron detector based on a plastic scintillator coupled to a digital readout. PANDORA can be used for any reaction study involving the emission of low energy neutrons (100 keV-10 MeV) where background suppression and an increased signal-to-noise ratio are crucial. The digital readout system provides an opportunity for pulse shape discrimination (PSD) of the detected particles as well as intelligent triggering based on PSD. The figure of merit results of PANDORA are compared to the data in literature. Using PANDORA, 91 ± 1% of all detected neutrons can be separated, while 91 ± 1% of the detected gamma rays can be excluded, reducing the gamma ray background by one order of magnitude.

  11. NEUTRON AND PHOTON DOSE MAPPING OF A DD NEUTRON GENERATOR.

    Science.gov (United States)

    Metwally, Walid A; Taqatqa, Osama A; Ballaith, Mohammed M; Chen, Allan X; Piestrup, Melvin A

    2017-11-01

    Neutron generators are an excellent tool that can be effectively utilized in educational institutions for applications such as neutron activation analysis, neutron radiography, and profiling and irradiation effects. For safety purposes, it is imperative that appropriate measures are taken in order to minimize the radiation dose from such devices to the operators, students and the public. This work presents the simulation and measurement results for the neutron and photon dose rates in the vicinity of the neutron generator installed at the University of Sharjah. A very good agreement is found between the simulated and measured dose rates. All of the public dose constraints were found to be met. The occupational dose constraint was also met after imposing a 200 cm no entry zone around the generator room. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Atomic collisions by neutrons-induced charged particles in water, protein and nucleic acid

    International Nuclear Information System (INIS)

    Bergman, R.

    1976-01-01

    The action of slow charged particles is peculiar in that atomic collisions are commonly invlolved. In atomic collisions, which are rare events when fast particles interact with matter, displacement of atoms and chemical bond-breakage is possible. Sufficiently energetic neutrons generate charged recoil particles in matter. Some of these are slow as compared to orbital electrons, but the energy transferred to such slow particles is generally relatively small. Yet, it contributes significantly to the dose absorbed from 0.1-30 keV neutrons. In tissue all recoils induced by neutrons of less than 30 keV are slow, and above 0.1 keV the absorbed dose due to collisiondominates over that due to capture reactions. The aim of the present paper is to identify those intervals of neutron energy in which atomic collision damage is most probable in living matter. The results of calculations presented here indicate that atomic collisions should be most significant for 0.5-3 keV neutrons. (author)

  13. Neutron-capture-activation cross sections of 9496Zr and 98100Mo at thermal and 30 keV energy

    International Nuclear Information System (INIS)

    Wyrick, J.M.; Poenitz, W.P.

    1982-01-01

    Neutron-capture cross sections of 94 96 Zr and 98 100 Mo were measured relative to the standard-capture cross section of gold at thermal and 30 keV neutron energies using the activation technique. The reported values are based upon available decay-scheme information

  14. Dose distributions in thorax inhomogeneity for fast neutron beam from NIRS cyclotron

    International Nuclear Information System (INIS)

    Kutsutani-Nakamura, Yuzuru; Furukawa, Shigeo; Iinuma, T.A.; Kawashima, Katsuhiro; Hoshino, Kazuo; Hiraoka, Takeshi; Maruyama, Takashi; Sakashita, Kunio; Tsunemoto, Hiroshi

    1990-01-01

    The power law tissue-air ratio (TAR) method developed by Batho appears to be practical use for inhomogeneity corrections to the dose calculated in a layered media for photon beam therapy. The validity was examined in applying the modified power law TAR and the isodose shift methods to the dose calculation in thorax tissue inhomogeneity containing the boundary region for fast neutron beam. The neutron beam is produced by bombarding a thick beryllium target with 30 MeV deuterons. Lung phantom was made of granulated tissue equivalent plastic, which resulted in density of 0.30 and 0.60 g/cm 3 . Depth dose distributions for neutron beam were measured in thorax phantom by an air-filled cylindrical ionization chamber with TE plastic wall. The power law TAR method considering TAR of zero depth at boundary was compared with the measured data and a good result was obtained that the calculated dose was within ±3 % against the measured. But the isodose shift method is not so good for dose calculation in thorax tissue inhomogeneity using fast neutron beam. (author)

  15. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  16. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  17. Measurement of photon mass attenuation coefficients of plutonium from 60 to 2615 keV

    International Nuclear Information System (INIS)

    Rettschlag, M.; Berndt, R.; Mortreau, P.

    2007-01-01

    Measurements have been made to determine plutonium photon mass attenuation coefficients by using a collimated-beam transmission method in the energy range from 60 to 2615 keV. These experimental results were compared with previous experimental and theoretical data. Good agreements are observed in the 240-800 keV energy range, whereas differences up to maximum 10% are observed out of these limits

  18. Using neutrons to measure keV temperatures in highly compressed plastic at multi-Gbar pressures

    Science.gov (United States)

    Nilsen, J.; Bachmann, B.; Zimmerman, G. B.; Hatarik, R.; Döppner, T.; Swift, D.; Hawreliak, J.; Collins, G. W.; Falcone, R. W.; Glenzer, S. H.; Kraus, D.; Landen, O. L.; Kritcher, A. L.

    2016-12-01

    We have designed an experiment for the National Ignition Facility to measure the Hugoniot of materials such as plastic at extreme pressures. The design employs a strong spherically converging shock launched through a solid ball of material using a hohlraum radiation drive. The shock front conditions can be characterized using X-ray radiography until background from shock coalescence overtakes the backlit signal. Shock coalescence at the center is predicted to reach tens of Gbars and can be further characterized by measuring the X-ray self-emission and 2.45 MeV neutrons emitted from the shock flash region. In this simulation design work the standard plastic sphere is replaced with a deuterated polyethylene sphere, CD2, that reaches sufficiently high densities and temperatures in the central hot spot to produce neutrons from Deuterium-Deuterium (DD) fusion reactions that can be measured by a neutron time of flight spectrometer (nTOF) and act as a temperature diagnostic. This paper focuses on the design of these experiments, based on an extensive suite of radiation-hydrodynamics simulations, and the interpretation of the predicted DD neutron signals. The simulations predict mean temperatures of 1 keV in the central hot spot with mean densities of 33 g/cc and mean pressures of 25 Gbar. A preliminary comparison with early experimental results looks promising with an average ion temperature of 1.06 ± 0.15 keV in the central hot spot estimated from the nTOF spectral width and measured neutron yield of 7.0 (±0.5) × 109 DD neutrons.

  19. Relative biological effectiveness measurements using murine lethality and survival of intestinal and hematopoietic stem cells after Fermilab neutrons compared to JANUS reactor neutrons and 60Co gamma rays

    International Nuclear Information System (INIS)

    Hanson, W.R.; Crouse, D.A.; Fry, R.J.M.; Ainsworth, E.J.

    1984-01-01

    The relative biological effectiveness (RBE) of the 25-MeV (average energy) neutron beam at the Fermi National Accelerator Laboratory was measured using murine bone marrow (LD/sub 50/30/) and gut (LD/sub 50/6/) lethality and killing of hematopoietic colony forming units (CFU-S) or intestinal clonogenic cells (ICC). The LD/sub 50/30/ and LD/sub 50/6/ for mice exposed to the Fermilab neutron beam were 6.6 and 8.7 Gy, respectively, intermediate between those of JANUS neutrons and 60 Co γ rays. The D 0 values for CFU-S and ICC were 47 cGy and 1.05 Gy, respectively, also intermediate between the lowest values found for JANUS neutrons and the highest values found after 60 Co γ rays. The split-dose survival ratios for CFU-S at intervals of 1-6 hr between doses were essentially 1.0 for both neutron sources. The 3-hr split-dose survival ratios for ICC were 1.0 for JANUS neutrons, 1.85 for Fermilab neutrons, and 6.5 for 60 Co γ rays. The RBE estimates for LD/sub 50/30/ were 1.5 and 2.3 for Fermilab and JANUS neutrons, respectively. Based on LD/sub 50/6/, the RBEs were 1.9 (Fermilab) and 3.0 (JANUS). The RBEs for CFU-S D 0 were 1.4 (Fermilab) and 1.9 (JANUS) and for jejunal microcolony D 0 1.4 (Fermilab) and 2.8 (JANUS)

  20. Assessment of fast and thermal neutron ambient dose equivalents around the KFUPM neutron source storage area using nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco, P. O. Box 13027, Dhahran 31311 (Saudi Arabia); Qureshi, M.A. [Center for Applied Physical Sciences, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-11-15

    A set of five {sup 241}Am-Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16Ci each and the other two are of 5Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters on their surfaces for thermal neutron detection via B10(n,{alpha})Li6 and Li6(n,{alpha})H3 nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks cm{sup -2}{mu}Sv{sup -1} and 31.5 alpha tracks cm{sup -2}{mu}Sv{sup -1}, respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as 182nSvh{sup -1} up to 10.4{mu}Svh{sup -1} whereas those for thermal neutron ranged from as low as 7nSvh{sup -1} up to 9.3{mu}Svh{sup -1}. The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and 182nSvh{sup -1} from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron

  1. Transmission line matching simulation for 350 MHz RF driver for 400 KeV (deuterium) RFQ based 14 MeV neutron source

    International Nuclear Information System (INIS)

    Sharma, Sonal; Pande, Manjiri; Handu, V.K.

    2009-01-01

    A 60 KW, 350 MHz tetrode based high power RF system is being developed for 400 KeV RFQ based 14 MeV neutron generator in Bhabha Atomic Research Centre to study physics of coupled neutron sources and subcritical assembly. This RF system requires a 2.5 kW RF driver which is being designed by using tetrode TH-393. At such high frequency i.e. 350 MHz, lumped components are not practically useful due to radiation losses. Therefore, techniques such as coaxial line with stub tuning are preferred, which minimizes these losses. Simulation of two such stub tuning based matched coaxial lines at the input and output of the tube has been done by using CST studio. CST STUDIO is a special tool for the 3D EM simulation of high frequency components

  2. Novel Concrete Chemistry Achieved with Low Dose Gamma Radiation Curing and Resistance to Neutron Activation

    Science.gov (United States)

    Burnham, Steven Robert

    As much as 50% of ageing-related problems with concrete structures can be attributed to con-struction deficiencies at the time of placement. The most influential time affecting longevity of concrete structures is the curing phase, or commonly the initial 28 days following its placement. A novel advanced atomistic analysis of novel concrete chemistry is presented in this dissertation with the objective to improve concrete structural properties and its longevity. Based on experiments and computational models, this novel concrete chemistry is discussed in two cases: (a) concrete chemistry changes when exposed to low-dose gamma radiation in its early curing stage, thus improving its strength in a shorter period of time then curing for the conventional 28 days; (b) concrete chemistry is controlled by its atomistic components to assure strength is not reduced but that its activation due to long-term exposure to neutron flux in nuclear power plants is negligible. High dose gamma radiation is well documented as a degradation mechanism that decreases concrete's compressive strength; however, the effects of low-dose gamma radiation on the initial curing phase of concrete, having never been studied before, proved its compressive strength increases. Using a 137 Cs source, concrete samples were subjected to gamma radiation during the initial curing phase for seven, 14, and 28 days. The compressive strength after seven days is improved for gamma cured concrete by 24% and after 14 days by 76%. Concrete shows no improvement in compressive strength after 28 days of exposure to gamma radiation, showing that there is a threshold effect. Scanning Electron Microscopy is used to examine the microstructure of low-dose gamma radiation where no damage to its microstructure is found, showing no difference between gamma cured and conventionally cured concrete. Molecular dynamics modeling based on the MOPAC package is used to study how gamma radiation during the curing stage improves

  3. Neutron doses to personnel from a 24 MeV betatron

    International Nuclear Information System (INIS)

    Beckham, W.A; Entwistle, R.F.

    1987-01-01

    Neutrons are produced by bombardment of most materials by high-energy photons. Because the x-ray shielding around high-energy x-ray generators may not have been designed with neutrons in mind there may be unexpected contributions to the radiation doses of staff working in the immediate vicinity. Neutron fluxes in the working area close to an Allis-Chalmers 24 MeV betatron have been measured using a lithium-6-loaded scintillator and the dose rates calculated. Hazard of staff has been found to be low; typical dose-equivalent rates in occupied areas range from 0.0042 to 0.012 mrem/hour. The flux of fast neutrons in the treatment room was found to be essentially zero. Measurements of neutron flux may be routinely performed using the scintillation detector (NE 912) described, and could usefully form part of the acceptance protocol for any new accelerator

  4. V79 survival following simultaneous or sequential irradiation by 15-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1983-01-01

    A unique tandem source irradiation facility, composed of an intense d-T neutron source and a 60 Co teletherapy unit, was used to investigate biological responses for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log-phase growth, were irradiated at 37 degrees C by either 14.8-MeV neutrons, 60 Co, or a mixture of 40% neutrons and 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons compared to that measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable, and for determination of environmental hazards to people occupationally exposed to mixtures of photons and neutrons

  5. V79 survival following simultaneous or sequential irradiation by 15-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1983-01-01

    A unique tandem source irradiation facility, composed of an intense d-T neutron source and a 60 Co teletherapy unit, was used to investigate biological responses for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log-phase growth, were irradiated at 37 0 C by either 14.8-MeV neutrons, 60 Co, or a mixture of 40% neutrons and 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons compared to that measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable, and for determination of environmental hazards to people occupationally exposed to mixtures of photons and neutrons

  6. Neutron/gamma dose separation by the multiple-ion-chamber technique

    International Nuclear Information System (INIS)

    Goetsch, S.J.

    1983-01-01

    Many mixed n/γ dosimetry systems rely on two dosimeters, one composed of a tissue-equivalent material and the other made from a non-hydrogenous material. The paired chamber technique works well in fields of neutron radiation nearly identical in spectral composition to that in which the dosimeters were calibrated. However, this technique is drastically compromised in phantom due to the degradation of the neutron spectrum. The three-dosimeter technique allows for the fall-off in neutron sensitivity of the two non-hydrogenous dosimeters. Precise and physically meaningful results were obtained with this technique with a D-T source in air and in phantom and with simultaneous D-T neutron and 60 Co gamma ray irradiation in air. The MORSE-CG coupled n/γ three-dimensional Monte Carlo code was employed to calculate neutron and gamma doses in a water phantom. Gamma doses calculated in phantom with this code were generally lower than corresponding ion chamber measurements. This can be explained by the departure of irradiation conditions from ideal narrow-beam geometry. 97 references

  7. Monoenergetic neutron fields for the calibration of neutron dosemeters at the accelerator facility of the PTB

    International Nuclear Information System (INIS)

    Lesiecki, H.; Cosack, M.; Schoelermann, H.

    1987-01-01

    The present state in the realization of monoenergetic standard neutron fields and the possibility of calibrating neutron dose- and doserate meters at the accelerator facility of the PTB are described. There are excellent conditions for the performance of irradiations in the neutron energy range of 1 keV to 14.8 MeV. (orig.) [de

  8. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1991-10-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modeling techniques and a knowledge of the radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well-chosen measurements are required to confirm the theoretical models. Neutron measurements were performed in a RANDO phantom using thermoluminescent dosemeters, track etch dosemeters, and a 1/2-in. (1.27-cm) tissue equivalent proportional counter in order to estimate neutron doses and dose equivalents within the phantom at specific locations. The phantom was exposed to bare and D 2 O-moderated 252 Cf neutrons at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and calculate organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared to the calculations. 8 refs., 3 figs., 3 tabs

  9. Cosmic radiation dose in aircraft - a neutron track etch detector

    Energy Technology Data Exchange (ETDEWEB)

    Vukovic, B.; Radolic, V.; Miklavcic, I.; Poje, M.; Varga, M. [Department of Physics, University of Osijek, 31000 Osijek, P.O. Box 125, Gajev trg 6 (Croatia); Planinic, J. [Department of Physics, University of Osijek, 31000 Osijek, P.O. Box 125, Gajev trg 6 (Croatia)], E-mail: planinic@ffos.hr

    2007-12-15

    Cosmic radiation bombards us at high altitude by ionizing particles. The radiation environment is a complex mixture of charged particles of solar and galactic origin, as well as of secondary particles produced in interaction of the galactic cosmic particles with the nuclei of atmosphere of the Earth. The radiation field at aircraft altitude consists of different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard ATR 42 and A 320 aircrafts (flight level of 8 and 11 km, respectively) was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter. The estimated occupational effective dose for the aircraft crew (A 320) working 500 h per year was 1.64 mSv. Other experiments, or dose rate measurements with the neutron dosimeter, consisting of LR-115 track detector and boron foil BN-1 or 10B converter, were performed on five intercontinental flights. Comparison of the dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level showed that the neutron component carried about 50% of the total dose. The dose rate measurements on the flights from the Middle Europe to the South and Middle America, then to Korea and Japan, showed that the flights over or near the equator region carried less dose rate; this was in accordance with the known geomagnetic latitude effect.

  10. Cosmic radiation dose in aircraft - a neutron track etch detector

    International Nuclear Information System (INIS)

    Vukovic, B.; Radolic, V.; Miklavcic, I.; Poje, M.; Varga, M.; Planinic, J.

    2007-01-01

    Cosmic radiation bombards us at high altitude by ionizing particles. The radiation environment is a complex mixture of charged particles of solar and galactic origin, as well as of secondary particles produced in interaction of the galactic cosmic particles with the nuclei of atmosphere of the Earth. The radiation field at aircraft altitude consists of different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard ATR 42 and A 320 aircrafts (flight level of 8 and 11 km, respectively) was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter. The estimated occupational effective dose for the aircraft crew (A 320) working 500 h per year was 1.64 mSv. Other experiments, or dose rate measurements with the neutron dosimeter, consisting of LR-115 track detector and boron foil BN-1 or 10B converter, were performed on five intercontinental flights. Comparison of the dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level showed that the neutron component carried about 50% of the total dose. The dose rate measurements on the flights from the Middle Europe to the South and Middle America, then to Korea and Japan, showed that the flights over or near the equator region carried less dose rate; this was in accordance with the known geomagnetic latitude effect

  11. Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels.

    Science.gov (United States)

    Riffel, Philipp; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Morelli, John N; Schmidt, Bernhard; Schoenberg, Stefan O; Henzler, Thomas

    2016-04-01

    Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. 20 patients (12 male; mean age 53±17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values 0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Neutron total cross section measurements in the energy region from 47 keV to 20 MeV

    International Nuclear Information System (INIS)

    Poenitz, W.P.; Whalen, J.F.

    1983-05-01

    Neutron total cross sections were measured for 26 elements. Data were obtained in the energy range from 47 keV to 20 MeV for 11 elements in the range of light-mass fission products. Previously reported measurements for eight heavy and actinide isotopes were extended to 20 MeV. Data were also obtained for Cu (47 keV to 1.4 MeV) and for Sc, Zn, Nd, Hf, and Pt (1.8 to 20 MeV). The present work is part of a continuing effort to provide accurate neutron total cross sections for evaluations and for optical-model parameteriztions. The latter are required for the derivation of other nuclear-data information of importance to applied programs. 37 references

  13. A 60 keV implanter for metals

    International Nuclear Information System (INIS)

    Leutenecker, R.; Ryssel, H.; Zeller, K.-H.; Spoehrle, H.P.

    1985-01-01

    The design and preliminary performance data of a 60 keV high current implanter for the implantation of non-separated ion beams into metals are described. The target chamber accepts samples up to 70 cm in diameter and is equipped with holders to implant ball bearings, axles and other components which have to be rotated during implantation. Samples are mounted on a rugged table which can move up to 35 kg for +-35 cm in the x and y directions. The implanter, including the vacuum system, is completely computer controlled. The ion source is equipped with an oven having a maximum temperature of 1200 0 C and can deliver ion beams of nitrogen as well as different metal ions such as tin and silver with currents up to 10 mA. (Auth.)

  14. Ultra Low Level Environmental Neutron Measurements Using Superheated Droplet Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, A.C. [Centro de Ciencias e Tecnologias Nucleares, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Estrada Nacional 10 - km 139.7, 2695-066 Bobadela LRS (Portugal); Centro de Fisica Nuclear, Universidade de Lisboa. Av. Prof. Gama Pinto, 2, 1649- 003 Lisboa (Portugal); Felizardo, M.; Girard, T.A.; Kling, A.; Ramos, A.R. [Centro de Fisica Nuclear, Universidade de Lisboa. Av. Prof. Gama Pinto, 2, 1649- 003 Lisboa (Portugal); Marques, J.G.; Prudencio, M.I.; Marques, R.; Carvalho, F.P. [Centro de Ciencias e Tecnologias Nucleares, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Estrada Nacional 10 - km 139.7, 2695-066 Bobadela LRS (Portugal)

    2015-07-01

    Through the application of superheated droplet detectors (SDDs), the SIMPLE project for the direct search for dark matter (DM) reached the most restrictive limits on the spin-dependent sector to date. The experiment is based on the detection of recoils following WIMP-nuclei interaction, mimicking those from neutron scattering. The thermodynamic operation conditions yield the SDDs intrinsically insensitive to radiations with linear energy transfer below ∼150 keVμm{sup -1} such as photons, electrons, muons and neutrons with energies below ∼40 keV. Underground facilities are increasingly employed for measurements in a low-level radiation background (DM search, gamma-spectroscopy, intrinsic soft-error rate measurements, etc.), where the rock overburden shields against cosmic radiation. In this environment the SDDs are sensitive only to α-particles and neutrons naturally emitted from the surrounding materials. Recently developed signal analysis techniques allow discrimination between neutron and α-induced signals. SDDs are therefore a promising instrument for low-level neutron and α measurements, namely environmental neutron measurements and α-contamination assays. In this work neutron measurements performed in the challenging conditions of the latest SIMPLE experiment (1500 mwe depth with 50-75 cm water shield) are reported. The results are compared with those obtained by detailed Monte Carlo simulations of the neutron background induced by {sup 238}U and {sup 232}Th traces in the facility, shielding and detector materials. Calculations of the neutron energy distribution yield the following neutron fluence rates (in 10{sup -8} cm{sup -2}s{sup -1}): thermal (<0.5 eV): 2.5; epithermal (0.5 eV-100 keV): 2.2; fast (>1 MeV): 3.9. Signal rates were derived using standard cross sections and codes routinely employed in reactor dosimetry. The measured and calculated neutron count rates per unit of active mass were 0.15 ct/kgd and 0.33 ct/kg-d respectively. As the major

  15. Low-energy x-ray dosimetry studies (6 to 16 keV) at SSRL beamline 1-5

    International Nuclear Information System (INIS)

    Ipe, N.E.; Chatterji, S.; Fassograve, A.; Kase, K.R.; Seefred, R.; Bilski, P.; Soares, C.

    1997-01-01

    Synchrotron radiation facilities provide a unique opportunity for low-energy x-ray dosimetry studies because of the availability of monochromatic x-ray beams. Results of such studies performed at the Stanford Synchrotron Radiation Laboratory (SSRL) are described. Polish lithium fluoride thermoluminescent dosemeters (TLDs), MTS-N(LiF:Mg, Ti- 0.4 mm thick), MCP-N (LiF:Mg, Cu, P - 0.4 mm thick) were exposed free in air to monochromatic x-rays (6 - 16 keV). These exposures were monitored with an SSRL ionization chamber. The responses (counts/Gy) of MTS-N and MCP-N were generally found to increase with increasing energy. The response at 16 keV is about 3 and 4 times higher than the response at 6 keV for MTS-N and MCP-N, respectively. Irradiation at 6 keV indicates a fairly linear dose response for both type of TLDs over a dose range of 0.01 to 0.4 Gy. In addition there appears to be no significant difference in responses between irradiating the TLDs from the front and the back sides. The energy response of the PTW ionization chamber type 23342 relative to the SSRL ionization chamber is within ±4.5% between 6 and 16 keV. Both the TLDs and the PTW ionization chamber can also be used for beam dosimetry. copyright 1997 American Institute of Physics

  16. Rapid Measurement of Neutron Dose Rate for Transport Index

    International Nuclear Information System (INIS)

    Morris, R.L.

    2000-01-01

    A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 μSv per hour (20 μrem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNPtrademark are reported for materials typical of those being shipped

  17. RBE/absorbed dose relationship of d(50)-Be neutrons determined for early intestinal tolerance in mice

    International Nuclear Information System (INIS)

    Gueulette, J.; Wambersie, A.

    1978-01-01

    RBE/absorbed dose relationship of d(50)-Be neutrons (ref.: 60 Co) was determined using intestinal tolerance in mice (LD50) after single and fractionated irradiation. RBE is 1.8 for a single fraction (about 1000 rad 60 Co dose); it increases when decreasing dose and reaches the plateau value of 2.8 for a 60 Co dose of about 200 rad. This RBE value is used for the clinical applications with the cyclotron 'Cyclone' at Louvain-la-Neuve [fr

  18. Alterations in water and electrolyte absorption in the rat colon following neutron irradiation: influence of neutron component and irradiation dose.

    Science.gov (United States)

    Dublineau, I; Ksas, B; Joubert, C; Aigueperse, J; Gourmelon, P; Griffiths, N M

    2002-12-01

    To study the absorptive function of rat colon following whole-body exposure to neutron irradiation, either to the same total dose with varying proportion of neutrons or to the same neutron proportion with an increasing irradiation dose. Different proportions of neutron irradiation were produced from the reactor SILENE using a fissile solution of uranium nitrate (8, 47 and 87% neutron). Water and electrolyte fluxes were measured in the rat in vivo under anaesthesia by insertion into the descending colon of an agarose gel cylinder simulating the faeces. Functional studies were completed by histological analyses. In the first set of experiments, rats received 3.8 Gy with various neutron percentages and were studied from 1 to 14 days after exposure. In the second set of experiments, rats were exposed to increasing doses of irradiation (1-4Gy) with a high neutron percentage (87%n) and were studied at 4 days after exposure. The absorptive capacity of rat colon was diminished by irradiation at 3-5 days, with a nadir at 4 days. The results demonstrate that an increase in the neutron proportion is associated with an amplification of the effects. Furthermore, a delay in the re-establishment of normal absorption was observed with the high neutron proportion (87%n). A dose-dependent reduction of water absorption by rat colon was also observed following neutron irradiation (87%n), with a 50% reduction at 3 Gy. Comparison of this dose-effect curve with the curve obtained following gamma (60)Co-irradiation indicates an RBE of 2.2 for absorptive colonic function in rat calculated at 4 days after exposure.

  19. The Influence of Used Construction Material and Its Thickness on the Neutron Dose Rate Around the Linear Accelerator - Experimental Results

    International Nuclear Information System (INIS)

    Krpan, I; Miklavcic, I.; Poje, M.; Radolic, V.; Vukovic, B.; Zivkovic, A.; Faj, D.; Ivkovic, A.

    2013-01-01

    Since linear accelerators for medical radiotherapy do not have active radioactive sources it makes them adequate from the radioprotection point of view. However, when operating at the energy higher than 10 MeV, they can become a source of unwanted neutron radiation in the giant dipole resonance reaction between the photon beam and the accelerator head material. Neutrons created in this reaction are almost isotropic in direction with an energy range between 700 keV and 1 MeV. During the accelerator installation and different phases of the construction work around the accelerator, a neutron dose rate at several important locations was investigated. Both passive (solid state nuclear track etched detectors - CR 39 and/or LR-115 with the 10B foil) and active detectors (Thermo Biorem FHT 752) were used. A higher photon dose rate was measured around the accelerator facility. An effective photon dose reduction was achieved using steel plates. However, this was the secondary source of neutrons in the reaction between the photons and steel plates, since higher values were measured. Neutron reduction was done by additional layers of barite concrete. A very conservative assessment of the effective dose was done for the medical personnel inside the control room. At the accelerator extreme operating regime (fixed accelerator direction - gantry angle, highest energy possible used), the neutron dose rate in the control room of 12 μSv/h was measured. Knowing the number of working days and number of patients per technician (per day), an exposure to the neutron dose of 1,1 mSv per year was calculated.(author)

  20. Cytogenetic characterization of low-dose hyper-radiosensitivity in Cobalt-60 irradiated human lymphoblastoid cells

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gnanada S. [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, MI 48201 (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States)

    2014-12-15

    Highlights: • Human cells were irradiated in G1 or G2 and evaluated for micronuclei and bridges. • Cells irradiated in G2 but not in G1 exhibit low dose hyper-radiosensitivity. • Response curves of cells irradiated in G2 do not fit a linear-no-threshold model. • Response curves of cells irradiated in G1 fit a linear-no-threshold model. - Abstract: The dose-effect relationships of cells exposed to ionizing radiation are frequently described by linear quadratic (LQ) models over an extended dose range. However, many mammalian cell lines, when acutely irradiated in G2 at doses ≤0.3 Gy, show hyper-radiosensitivity (HRS) as measured by reduced clonogenic cell survival, thereby indicating greater cell lethality than is predicted by extrapolation from high-dose responses. We therefore hypothesized that the cytogenetic response in G2 cells to low doses would also be steeper than predicted by LQ extrapolation from high doses. We tested our hypothesis by exposing four normal human lymphoblastoid cell lines to 0–400 cGy of Cobalt-60 gamma radiation. The cytokinesis block micronucleus assay was used to determine the frequencies of micronuclei and nucleoplasmic bridges. To characterize the dependence of the cytogenetic damage on dose, univariate and multivariate regression analyses were used to compare the responses in the low- (HRS) and high-dose response regions. Our data indicate that the slope of the response for all four cell lines at ≤20 cGy during G2 is greater than predicted by an LQ extrapolation from the high-dose responses for both micronuclei and bridges. These results suggest that the biological consequences of low-dose exposures could be underestimated and may not provide accurate risk assessments following such exposures.

  1. Contribution to the study of nuclear structure using neutron total cross-section measurements between 400 and 1200 keV: isolated resonances and intermediate structure; Contribution a l'etude de la structure nucleaire par des mesures de sections efficaces neutroniques entre 400 keV et 1200 keV. Resonances isolees et structure intermediaire

    Energy Technology Data Exchange (ETDEWEB)

    Cabe, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-15

    The neutron total cross sections have been measured over the energy range 400 keV - 1200 keV for fluorine, aluminium, silicon, phosphorus, vanadium, chromium, manganese, iron, nickel, cobalt and lead with an energy spread of 3 keV. The neutrons were produced by the T (p,n) {sup 3}He reaction, the proton beam was supplied by a 2 MeV Van de Graaff. The structure in {sup 56}Fe has been studied in a more detailed way by measuring six angular distributions in the above range and the elastic scattering excitation curves at four angles. The measurements have made it possible to show the existence of the compound nucleus, as well as the presence of an intermediate structure in certain nuclei. (author) [French] Nous avons mesure les sections efficaces totales neutroniques entre 400 keV et 1200 keV du fluor, de l'aluminium, du silicium, du phosphore, du vanadium, du chrome, du manganese, du fer, du nickel, du cobalt et du plomb avec une dispersion en energie de 3 keV. Les neutrons etaient produits a l'aide de la reaction T (p,n) {sup 3}He, les protons etant acceleres par un Van de Graaff 2 MeV. Nous presentons de plus quatre courbes d'excitation de la diffusion elastique des neutrons sur le fer ainsi que six distributions angulaires. Ces mesures ont permis de mettre en evidence un certain nombres de resonances du noyau compose, ainsi que la presence d'une structure intermediaire dans. certains noyaux. (auteur)

  2. Fast neutron flux and intracranial dose distribution at a neutron irradiation facility

    International Nuclear Information System (INIS)

    Matsumoto, Tetsuo; Aizawa, Otohiko; Nozaki, Tetsuya

    1981-01-01

    A head phantom filled with water was used to measure the fast neutron flux using 115 In(n, n')sup(115m)In and 103 Rh(n, n')sup(103m)Rh reactions. γ-ray from sup(115m)In and x-ray from sup(103m)Rh were detected by a Ge(Li) and a Na(Tl)I counter, respectively. TLD was used to investigate the γ-dose rate distribution inside the phantom. Flux of fast neutron inside the phantom was about 1 x 10 6 n/cm 2 sec, which was 3 order smaller than that of thermal neutron. The fast neutron flux decreased to 1/10 at 15 cm depth, and γ-dose rate was about 200 R/h at 100 kW inside the phantom. Total dose at the surface was 350 rad/h, to which, fast neutrons contributed more than γ-rays. The rate of fast neutron dose was about 10% of thermal neutron's in Kerma dose unit (rad), however, the rate was highly dependent on RBE value. (Nakanishi, T.)

  3. Catalogue of neutron spectra

    International Nuclear Information System (INIS)

    Buxerolle, M.; Massoutie, M.; Kurdjian, J.

    1987-09-01

    Neutron dosimetry problems have arisen as a result of developments in the applications of nuclear energy. The largest number of possible irradiation situations has been collected: they are presented in the form of a compilation of 44 neutron spectra. Diagrams show the variations of energy fluence and energy fluence weighted by the dose equivalent/fluence conversion factor, with the logarithm of the corresponding energy. The equivalent dose distributions are presented as percentages for the following energy bins: 0.01 eV/0.5 eV/50 keV/1 MeV/5 MeV/15 MeV. The dose equivalent, the mean energy and the effective energy for the dose equivalent for 1 neutron cm -2 are also given [fr

  4. Precipitate evolution in low-nickel austenitic stainless steels during neutron irradiation at very low dose rates

    International Nuclear Information System (INIS)

    Isobe, Y.; Sagisaka, M.; Garner, F.; Okita, T.

    2007-01-01

    Full text of publication follows: Not all components of a fusion reactor will be subjected to high atomic displacement rates. Some components outside the plasma containment may experience relatively low displacement rates but data generated under long-term irradiation at low dpa rates is hard to obtain. In another study the neutron-induced microstructural evolution in response to long term irradiation at very low dose rates was studied for a Russian low-nickel austenitic stainless steel that is analogous to AISI 304. The irradiated samples were obtained from an out-of-core anti-crush support column for the BN-600 fast reactor with doses ranging from 1.5 to 22 dpa generated at 3x10 -9 to 4x10 -8 dpa/s. The irradiation temperatures were in a very narrow range of 370-375 deg. C. Microstructural observation showed that in addition to voids and dislocations, an unexpectedly high density of small carbide precipitates was formed that are not usually observed at higher dpa rates in this temperature range. These results required us to ask if such unexpected precipitation was anomalous or was a general feature of low-flux, long-term irradiation. It is shown in this paper that a similar behavior was observed in a western stainless steel, namely AISI 304 stainless steel, irradiated at similar temperatures and dpa rates in the EBR-II fast reactor, indicating that irradiation at low dpa rates for many years leads to a different precipitate microstructure and therefore different associated changes in matrix composition than are generated at higher dpa rates. One consequence of this precipitation is a reduced lattice parameter of the alloy matrix, leading to densification that increases in strength with increasing temperature and dose. A. non-destructive method to evaluate these precipitates is under development and is also discussed in this paper. (authors)

  5. Subthreshold neutron interrogator for detection of radioactive materials

    Science.gov (United States)

    Evans, Michael L.; Menlove, Howard O.; Baker, Michael P.

    1980-01-01

    A device for detecting fissionable material such as uranium in low concentrations by interrogating with photoneutrons at energy levels below 500 keV, and typically about 26 keV. Induced fast neutrons having energies above 500 keV by the interrogated fissionable material are detected by a liquid scintillator or recoil proportional counter which is sensitive to the induced fast neutrons. Since the induced fast neutrons are proportional to the concentration of fissionable material, detection of induced fast neutrons indicate concentration of the fissionable material.

  6. The teratogenic effects of low dose 60Co γ-rays on the early pregnant rats

    International Nuclear Information System (INIS)

    Lu Chunlin

    1991-01-01

    The pregnant Wistar rats were exposed to 0.5 Gy and 1.0 Gy 60 Co γ-rays at the 9th day after conception. The results: 60 Co γ-rays at dose of 1.0 Gy could induced many defects: excenphaly, hydrocephalus, gastroschisis, cleft palate and cleft lip, anophthalmia, microphthalmia, shorten tail and absent tail in surviving fetuses. The growth retardation was found from the parameters of fetal weight, height, head circle and development of skeleton. In the group of radiation dose 0.5 Gy, only hydrocephalus, absent tail and growth retardation of skeleton appeared. The results suggest that low-dose exposure in the early pregnant rats can induce fetal defects and growth retardation. The probable mechanism of teratogen and growth retardation was discussed. The cAMP levels of brain and liver of rat fetuses were reported

  7. Optimize of Deuteron Current of 150 keV, 1 mA Neutron Generator

    International Nuclear Information System (INIS)

    Sri Sulamdari; Djasiman

    2003-01-01

    It has been characterized a 150 keV/1 mA Neutron Generator. It has been used some local components, except accelerator tube and vacuum system. To produce neutron, it has been used a deuterium gas bombarded into tritium target through reaction 3 H(d,n) 4 He. For preliminary experiment, we used the air as an ion source. The beam current of deuteron as a function of process parameters are presented in this paper. It's found that the optimum beam current of deuteron was 1000 μA, and this conditions was achieved at accelerations voltage 30 kV, extraction voltage 5 kV, guide voltage -11 kV and vacuum 10 -6 mbar. (author)

  8. Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's [thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Jenkins, T.M.; Busick, D.D.

    1987-03-01

    TLD's replaced film badges in the early 1970's for all dose equivalent monitoring, both neutron and photon, and for all locations at SLAC. The photon TLD's, composed of Li-7 loaded teflon discs, are calibrated using conventional gamma-ray sources; i.e., Co-60, Cs-137, etc. For these TLD's a nominal value of 1 nC/mrem is used, and is independent of source energy for 100 keV to 3 MeV. Since measured dose equivalents at SLAC are only a small fraction of the allowable levels, it was not deemed necessary to develop neutron dosimeters which would measure dose equivalent accurately for all possible neutron spectra. Today, wallet TLD's, composed of pairs of Li-7 and Li-6 discs, are used, with the Li-6 measuring only thermal neutrons; i.e., they aren't moderated in any way to make them sensitive to neutrons with energies greater than thermal. The assumption is made that there is a correlation between thermal neutron fluences and fast neutron fluences around the research area where almost all neutron doses (exclusive of sealed sources) are received. The calibration factor for these Li-6 TLD's is 1 nC/mrem of fast neutrons. The method of determining the validity of this calibration is the subject of this note. 4 refs., 9 figs., 1 tab

  9. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  10. Development of neutron dosimeter using CR-39 for measurement of ambient dose equivalent

    International Nuclear Information System (INIS)

    Maki, Daisuke; Shinozaki, Wakako; Ohguchi, Hiroyuki; Yamamoto, Takayoshi; Nakamura, Takayoshi

    2010-01-01

    A CR-39 has good advantages such as cumulative type dosimeter, small fading effect and gamma-ray insensitive. Therefore, we developed the wide energy-range environmental neutron dosimeter using eight CR-39s for area monitoring in this study. This dosimeter is made of octagonal columnar polyethylene block which height is 60 mm and bottom side is 25 mm. The dosimeter contains two types of CR-39s for fast neutron detection and slow neutron detection. Four CR-39s for fast neutron detection are used for detection of recoil protons produced by H (n, p) reactions. Four CR-39s for slow neutron detection are used with boron nitride converter to detect alpha-rays produced by 10 B (n, α) 7 Li reactions. Ambient dose equivalent is obtained by adding the number of etch-pits observed in four CR-39s for fast neutron detection to the number of etch-pits observed in four CR-39s for slow neutron detection with appropriate constants respectively. Dosimeters were irradiated with some energetic neutrons and evaluated results of ambient dose equivalent were compared with results from neutron transport calculations. Energy response of dosimeter shows good agreement with neutron fluence to ambient dose equivalent conversion coefficients. Directional dependence of dosimeter is at the same level as the rem-counter. (author)

  11. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  12. Development of a filtered neutron field in KUR. In behalf of biological irradiation experiments

    International Nuclear Information System (INIS)

    Sato, Takashi; Utsuro, Masahiko; Utsumi, Hiroshi

    1995-07-01

    Very little direct measurements have been made of the biological effects of neutrons below 100keV. Recently, an iron-filtered 24keV neutron beam of Harwell Materials Testing Reactor, PLUTO, was reported to be highly efficient in inducing chromosome aberrations; the efficiency being comparable to that of fission neutrons. This results could have serious repercussions for radiation protection standards as the ICRP assume a decrease in neutron RBE below 100keV. The investigations reported here have as their primary purpose the production of neutron beams at the 24keV iron window energy, using the B-1 experimental facility of the Kyoto University Research Reactor (KUR) at the Research Reactor Institute, Kyoto University (KURRI). The filtered neutron filed for biomedical applications is designed to maximized the contributions of neutrons with other energies and gamma-rays. The characteristics of the radiation field were obtained by the simple transmission calculations for Fe(45cm) and Al(35cm) filters, by using the Monte Carlo code MCN P, and by the measurement of nuclear heating for Fe and Al filter pieces. The 24keV neutron flux and gamma-ray dose rate were measured using a proton recoil counter and TLDs, respectively. The measured findings are as follows: The 24keV neutron flux at the irradiation field was approximately 1x10 6 n/cm 2 /s, and the gamma-ray dose rate was 1.0Gy/h at the surface of the B-1 plug. Nuclear heating of the filter materials was 5.2mW/g for Fe and 4mW/g for Al, in maximum. (author)

  13. High energy resolution measurement of the 238U neutron capture yield in the energy region between 1 and 100 keV

    International Nuclear Information System (INIS)

    Machlin, R.L.; Perez, R.B.; de Saussure, G.; Ingle, R.W.

    1988-01-01

    A measurement of the 238 U neutron capture yield was performed at the 150 meter flight-path of the ORELA facility on two 238 U samples (0.01224 and 0.0031 atomsbarn). The capture yeild data were normalized by Moxon's small resonance method. The energy resolution achieved in this measurement frequently resulted in doublet and triplet splittings of what appeared to be single resonance in previous measurements. This resolution should allow extension of the resolved resonance energy region in 238 U from the present 4-keV limit up to 15 or 20 keV incident neutron energy. Some 200 small resonances of the ( 238 U /plus/ n) compound nucleus have been observed which had not been detected in transmission measurement, in the energy range from 250 eV to 10 keV

  14. Critical study of some soft-tissue equivalent material. Sensitivity to neutrons of 1 keV to 14 MeV; Etude critique de quelques materiaux equivalents aux tissus mous. Sensibilite aux neutrons de 1 keV a 14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Kerviler, H de; Pages, L; Tardy-Joubert, Ph [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Authors have studied the elastic and inelastic reactions on various elements contribution to kerma in standard soft tissue and as a function of neutron energy from 1 keV to 14 MeV the ratio of kerma in tissue equivalent material to kerma in soft tissue. The results of calculations are made for materials without hydrogen in view to state exactly their neutron sensitivity and for the following hydrogenous materials: Rossi and Failla plastic, MixD, pure polyethylene and a new CEA tissue equivalent (a magnesium fluoride and polyethylene compound). Results for {gamma}-rays are given. (authors) [French] Les auteurs ont etudie la contribution au kerma total des reactions elastiques et inelastiques sur les divers composants du tissu mou standard et la variation, en fonction de l'energie des neutrons de 1 keV a 14 MeV, du rapport des kermas dans differents materiaux equivalents au tissu au kerma dans les tissus mous. Les materiaux etudies sont des materiaux sans hydrogene afin de preciser leur sensibilite aux neutrons et les materiaux hydrogenes suivants: plastique de Rossi et Failla, polyethylene pur, MixD, nouveau plastique CEA a base de polyethylene et de fluorure de magnesium. Les resultats pour les photons sont egalement rappeles. (auteurs)

  15. A {mu}TPC detector for the characterization of low energy neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Golabek, C., E-mail: cedric.golabek@irsn.fr [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Billard, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France); Allaoua, A. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Bosson, G.; Bourrion, O.; Grignon, C.; Guillaudin, O. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France); Lebreton, L., E-mail: lena.lebreton@irsn.fr [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Mayet, F. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France); Petit, M. [Laboratoire de Metrologie et de Dosimetrie des Neutrons, IRSN Cadarache, 13115 Saint-Paul-Lez-Durance (France); Richer, J.-P.; Santos, D. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des Martyrs, 38026 Grenoble (France)

    2012-06-21

    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 8 keV up to 1 MeV. In this work we present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of these neutron fields.

  16. μ-TPC: a future standard instrument for low energy neutron field characterization

    International Nuclear Information System (INIS)

    Maire, D.; Lebreton, L.; Petit, M.; Billard, J.; Bourrion, O.; Bosson, G.; Guillaudin, O.; Lamblin, J.; Mayet, F.; Medard, J.; Muraz, J.F.; Richer, J.P.; Riffard, Q.; Santos, D.

    2013-06-01

    In order to measure energy of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, μ-TPC (Micro Time Projection Chamber), carried out in collaboration with the LPSC (Laboratoire de Physique Subatomique et de Cosmologie), is based on the nucleus recoil detector principle. The instrument will be presented with the associated method to measure the neutron energy. This article will emphasize the proton energy calibration procedure and energy measurements of a neutron field produced at 127 keV on the IRSN facility AMANDE. Finally the COMIMAC device, dedicated to the calibration, will be described. This original device, developed at the LPSC, is able to produce proton and electron beams with an accurate energy ranging from 1 keV to 50 keV. (authors)

  17. Verification of an effective dose equivalent model for neutrons

    International Nuclear Information System (INIS)

    Tanner, J.E.; Piper, R.K.; Leonowich, J.A.; Faust, L.G.

    1992-01-01

    Since the effective dose equivalent, based on the weighted sum of organ dose equivalents, is not a directly measurable quantity, it must be estimated with the assistance of computer modelling techniques and a knowledge of the incident radiation field. Although extreme accuracy is not necessary for radiation protection purposes, a few well chosen measurements are required to confirm the theoretical models. Neutron doses and dose equivalents were measured in a RANDO phantom at specific locations using thermoluminescence dosemeters, etched track dosemeters, and a 1.27 cm (1/2 in) tissue-equivalent proportional counter. The phantom was exposed to a bare and a D 2 O-moderated 252 Cf neutron source at the Pacific Northwest Laboratory's Low Scatter Facility. The Monte Carlo code MCNP with the MIRD-V mathematical phantom was used to model the human body and to calculate the organ doses and dose equivalents. The experimental methods are described and the results of the measurements are compared with the calculations. (author)

  18. Resonance neutron capture in 23Na and 27Al from 3 to 600 keV

    International Nuclear Information System (INIS)

    Musgrove, A.R. de L.; Allen, B.J.; Macklin, R.L.

    1978-01-01

    The radiative capture cross sections of 23 Na and 27 Al were measured with the high resolution facility at the 40 m station of the Oak Ridge Electron Linear Accelerator. Resonance parameters for the individual resonances below 600 keV are given. Particular care was taken to correct the data for prompt neutron scattering effects by Monte Carlo methods

  19. Ultra thin buried oxide layers formed by low dose Simox process

    Energy Technology Data Exchange (ETDEWEB)

    Aspar, B.; Pudda, C.; Papon, A.M. [CEA Centre d`Etudes de Grenoble, 38 (France). Lab. d`Electronique et d`Instrumentation; Auberton Herve, A.J.; Lamure, J.M. [SOITEC, 38 - Grenoble (France)

    1994-12-31

    Oxygen low dose implantation is studied for two implantation energies. For 190 keV, a continuous buried oxide layer is obtained with a high dislocation density in the top silicon layer due to SiO{sub 2} precipitates. For 120 keV, this silicon layer is free of SiO{sub 2} precipitate and has a low dislocation density. Low density of pin-holes is observed in the buried oxide. The influence of silicon islands in the buried oxide on the breakdown electric fields is discussed. (authors). 6 refs., 5 figs.

  20. Ultra thin buried oxide layers formed by low dose Simox process

    International Nuclear Information System (INIS)

    Aspar, B.; Pudda, C.; Papon, A.M.

    1994-01-01

    Oxygen low dose implantation is studied for two implantation energies. For 190 keV, a continuous buried oxide layer is obtained with a high dislocation density in the top silicon layer due to SiO 2 precipitates. For 120 keV, this silicon layer is free of SiO 2 precipitate and has a low dislocation density. Low density of pin-holes is observed in the buried oxide. The influence of silicon islands in the buried oxide on the breakdown electric fields is discussed. (authors). 6 refs., 5 figs

  1. The experimental method for neutron dose-equivalent detection

    International Nuclear Information System (INIS)

    Ji Changsong

    1992-01-01

    A new method, for getting neutron dose-equivalent Cd rode absorption method is described. The method adopts Cd-rode-swarm buck absorption, which greatly improved the neutron sensitivity and simplified the adjustment method. By this method, the author has developed BH3105 model neutron dose equivalent meter, the sensitivity of this instrument reach 10 cps/μSvh -1 . γ-ray depression rate reaches 4000:1, the measurement range is 0.1 μSv/h-10 6 μSv/h. The energy response is good (from thermal neutron-14 MeV neutron), this instrument can be used to measure the dose equivalent of the neutron areas

  2. Late biological effects in the lung of C3H inbred mice following exposure to fast neutrons and 60Co-γ-rays

    International Nuclear Information System (INIS)

    Magdon, E.

    1980-01-01

    Histological changes in the lung tissue following local irradiation of the thorax of C 3 H inbred mice were analyzed. The investigation was continued up to 500 d following irradiation with 2 - 8 Gy neutrons and 4 - 30 Gy 60 Co γ-rays, respectively. The study revealed a clear dose dependence and higher effectivity of fast neutrons as to the late effects of the lungs. An increase of the portion of affected connective tissue in the lung was demonstrable already after a dose of 2.5 Gy neutrons and 5 Gy 60 Co γ-rays, respectively. The RBE of fast neutrons for late biological effects on the lung is discussed in connection with previous findings for the RBE of acute effects on tumor and normal tissue. (author)

  3. Observation of a low-lying neutron-unbound state in 19C

    International Nuclear Information System (INIS)

    Thoennessen, M.; Mosby, S.; Badger, N.S.; Baumann, T.; Bazin, D.; Bennett, M.; Brown, J.; Christian, G.; DeYoung, P.A.; Finck, J.E.; Gardner, M.; Hook, E.A.; Luther, B.; Meyer, D.A.; Mosby, M.; Rogers, W.F.

    2013-01-01

    Proton removal reactions from a secondary 22 N beam were utilized to populate unbound states in neutron-rich carbon isotopes. Neutrons were measured with the Modular Neutron Array (MoNA) in coincidence with carbon fragments. A resonance with a decay energy of 76(14) keV was observed in the system 18 C+n corresponding to a state in 19 C at an excitation energy of 653(95) keV. This resonance could correspond to the first 5/2 + state which was recently speculated to be unbound in order to describe 1n and 2n removal cross section measurements from 20 C

  4. Explosion of a low mass neutron star

    International Nuclear Information System (INIS)

    Blinnikov, S.I.; Imshennik, V.S.; Nadyozhin, D.K.; Novikov, I.D.; Polnarev, A.G.; AN SSSR, Moscow. Fizicheskij Inst.); Perevodchikova, T.V.

    1990-01-01

    The hydrodynamical disruption of a low mass neutron star is investigated for the case when the stellar mass becomes smaller than the minimum value, M min ≅0.1 M sun . The final phase of the process is shown to proceed explosively, leading to an expansion of all the star, with a kinetic energy of 4.8 MeV per nucleon. The results of calculations are virtually independent of the way in which the neutron star mass goes down below M min (mass exchange in a close binary stellar system, nucleon decay, or some effective mass loss due to a hypothetical decrease of the gravitational constant). The neutron star disruption is followed by a short (0.01-0.1 s) burst of thermal hard X-rays and soft gamma-rays (kT=10-100 keV) with a subsequent much more prolonged tail of radiation induced by decays of long-lived radioactive nuclides. Some fraction of the explosion energy may be emitted in the form of neutrinos. (orig.)

  5. The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    Science.gov (United States)

    Schmitz, T; Bassler, N; Blaickner, M; Ziegner, M; Hsiao, M C; Liu, Y H; Koivunoro, H; Auterinen, I; Serén, T; Kotiluoto, P; Palmans, H; Sharpe, P; Langguth, P; Hampel, G

    2015-01-01

    The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a (60)Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes fluka and mcnp. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen & Olsen alanine response model. The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. The alanine detector can be used without

  6. Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Seely, J. F., E-mail: seelyjf@gmail.com; Feldman, U. [Artep Inc., 2922 Excelsior Springs Court, Ellicott City, Maryland 21042 (United States); Glover, J. L.; Hudson, L. T.; Ralchenko, Y.; Henins, Albert [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Pereira, N. [Ecopulse Inc., P. O. Box 528, Springfield, Virginia 22152 (United States); Di Stefano, C. A.; Kuranz, C. C.; Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Chen, Hui; Williams, G. J.; Park, J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2014-11-15

    A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10–60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 μm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10–60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

  7. Evaluation of Neutron Response of Criticality Accident Alarm System Detector to Quasi-Monoenergetic 24 keV Neutrons

    Science.gov (United States)

    Tsujimura, Norio; Yoshida, Tadayoshi; Yashima, Hiroshi

    The criticality accident alarm system (CAAS), which was recently developed and installed at the Japan Atomic Energy Agency's Tokai Reprocessing Plant, consists of a plastic scintillator combined with a cadmium-lined polyethylene moderator and thereby responds to both neutrons and gamma rays. To evaluate the neutron absorbed dose rate response of the CAAS detector, a 24 keV quasi-monoenergetic neutron irradiation experiment was performed at the B-1 facility of the Kyoto University Research Reactor. The detector's evaluated neutron response was confirmed to agree reasonably well with prior computer-predicted responses.

  8. Sputtering of thin benzene and polystyrene overlayers by keV Ga and C60 bombardment

    International Nuclear Information System (INIS)

    Czerwinski, B.; Delcorte, A.; Garrison, B.J.; Samson, R.; Winograd, N.; Postawa, Z.

    2006-01-01

    The mechanisms of ion-stimulated desorption of thin organic overlayers deposited on metal substrates by mono- and polyatomic projectiles are examined using molecular dynamics (MD) computer simulations. A monolayer of polystyrene tetramers (PS4) physisorbed on Ag{1 1 1} is irradiated by 15 keV Ga and C 60 projectiles at normal incidence. The results are compared with the data obtained for a benzene overlayer to investigate the differences in sputtering mechanisms of weakly and strongly bound organic molecules. The results indicate that the sputtering yield decreases with the increase of the binding energy and the average kinetic energy of parent molecules is shifted toward higher kinetic energy. Although the total sputtering yield of organic material is larger for 15 keV C 60 , the impact of this projectile leads to a significant fragmentation of ejected species. As a result, the yield of the intact molecules is comparable for C 60 and Ga projectiles. Our data indicate that chemical analysis of the very thin organic films performed by detection of sputtered neutrals will not benefit from the use of C 60 projectiles

  9. An absolute measurement of 252Cf prompt fission neutron spectrum at low energy range

    International Nuclear Information System (INIS)

    Lajtai, A.; Dyachenko, P.P.; Kutzaeva, L.S.; Kononov, V.N.; Androsenko, P.A.; Androsenko, A.A.

    1983-01-01

    Prompt neutron energy spectrum at low energies (25 keV 252 Cf spontaneous fission has been measured with a time-of-flight technique on a 30 cm flight-path. Ionization chamber and lithium-glass were used as fission fragment and neutron detectors, respectively. Lithium glasses of NE-912 (containing 6 Li) and of NE-913 (containing 7 Li) 45 mm in diameter and 9.5 mm in thickness have been employed alternatively, for the registration of fission neutrons and gammas. For the correct determination of the multiscattering effects - the main difficulty of the low energy neutron spectrum measurements - a special geometry for the neutron detector was used. Special attention was paid also to the determination of the absolute efficiency of the neutron detector. The real response function of the spectrometer was determined by a Monte-Carlo calculation. The scattering material content of the ionization chamber containing a 252 Cf source was minimized. As a result of this measurement a prompt fission neutron spectrum of Maxwell type with a T=1.42 MeV parameter was obtained at this low energy range. We did not find any neutron excess or irregularities over the Maxwellian. (author)

  10. Evaluation of cross sections for neutron interactions with {sup 238}U in the energy region between 5 keV and 150 keV

    Energy Technology Data Exchange (ETDEWEB)

    Sirakov, I. [Institute for Nuclear Research and Nuclear Energy, Sofia (Bulgaria); Capote, R.; Trkov, A. [International Atomic Energy Agency, NAPC-Nuclear Data Section, Vienna (Austria); Gritzay, O. [Institute for Nuclear Research, Kyiv (Ukraine); Kim, H.I. [Korea Atomic Energy Research Institute, Nuclear Data Center, Daejeon (Korea, Republic of); Kopecky, S.; Paradela, C.; Schillebeeckx, P. [European Commission, Joint Research Centre, Geel (Belgium); Kos, B. [Jozef Stefan Institute, Ljubljana (Slovenia); Pronyaev, V.G. [Rosatom State Corporation, Atomsrandart, Moscow (Russian Federation)

    2017-10-15

    Cross sections for neutron interactions with {sup 238}U in the energy region from 5 keV to 150 keV have been evaluated. Average total and capture cross sections have been derived from a least squares analysis using experimental data reported in the literature. The resulting cross sections have been parameterised in terms of average resonance parameters maintaining full consistency with results of optical model calculations by using a dispersive coupled channel optical model potential. The average compound partial cross sections have been expressed in terms of transmission coefficients by applying the Hauser-Feshbach statistical reaction theory including width-fluctuations. A generalized single-level representation compatible with the energy-dependent options of the ENDF-6 format has been applied using standard boundary conditions. The results have been transferred into a full ENDF-6 compatible data file. (orig.)

  11. Medical and biological requirements for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gahbauer, R.; Goodman, J.H.; Kanellitsas, C.; Clendenon, N.; Blue, J.

    1986-01-01

    In conventional radiation therapy, tumor doses applied to most solid tumors are limited by the tolerance of normal tissues. The promise of Boron Neutron Capture Therapy lies in its potential to deposit high doses of radiation very specifically to tumor tissue. Theoretically ratios of tumor to normal tissue doses can be achieved significantly higher than conventional radiotherapeutic techniques would allow. Effective dose distributions obtainable are a complex function of the neutron beam characteristics and the macro and micro distributions of boron in tumor and normal tissues. Effective RBE doses are calculated in tumors and normal tissue for thermal, epithermal and 2 keV neutrons

  12. Alanine and TLD coupled detectors for fast neutron dose measurements in neutron capture therapy (NCT)

    Energy Technology Data Exchange (ETDEWEB)

    Cecilia, A.; Baccaro, S.; Cemmi, A. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Colli, V.; Gambarini, G. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy); Rosi, G. [ENEA-FIS-ION, Casaccia RC, Via Anguillarese 301, 00060 Santa Maria di Galeria, Rome (Italy); Scolari, L. [Dept. of Physics of the Univ., INFN, Via Celoria 16, 20133 Milan (Italy)

    2004-07-01

    A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF{sub 2}:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH{sub 3}CH(NH{sub 2})COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT. (authors)

  13. In-Situ Spectrometry of Neutrons

    Science.gov (United States)

    Maurer, Richard H.

    1999-01-01

    High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much

  14. Evaluation of mixed energy neutron doses using TLD NG-67 type

    International Nuclear Information System (INIS)

    Akhadi, Mukhlis; Thoyib Thamrin, M; Usmiyati Dewi, K.

    2000-01-01

    A research has been carried out to develop dose evaluation method of mixed neutron source with its neutron doses can be classified to two groups, I.e neutron doses with energy ≥ 0.5 eV and thermal neutron doses with energy less than 0.5 e V consist of epithermal and fast neutron, but in this research they were classified as fast neutron. Development of this dose evaluation method was carried out by sensitivity (S) intercomparison of TLD-600 to fast neutron, mixed energy neutron of nuclear rectors, and thermal neutron. From the experiment it was obtained that the value of Sfast : Sreactor : Sthermal = 0.005 : 0.010 : 1. Calibration factor (CF) of TLD is defined as 1/S. from the sensitivity data it can be obtained that the value of Cffast : Cfreactor : Cfthermal = 200 :100 : 1. The value of Cfreactor can be applied for mixed energy neutron doses evaluation of TLD-600. Key word : dosemeter, neutron dose, calibration factor, fast neutron, thermal neutron, nuclear reactor

  15. Use of prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Priyada, P.; Sarkar, P.K., E-mail: pradip.sarkar@manipal.edu

    2015-06-11

    The possibility of using measured prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent is explored theoretically. Monte Carlo simulations have been carried out using the FLUKA code to calculate the response of a high density polyethylene cylinder to emit prompt gammas from interaction of neutrons with the nuclei of hydrogen and carbon present in polyethylene. The neutron energy dependent responses of hydrogen and carbon nuclei are combined appropriately to match the energy dependent neutron fluence to ambient dose equivalent conversion coefficients. The proposed method is tested initially with simulated spectra and then validated using experimental measurements with an Am–Be neutron source. Experimental measurements and theoretical simulations have established the feasibility of estimating neutron ambient dose equivalent using measured neutron induced prompt gammas emitted from polyethylene with an overestimation of neutron dose at very low energies. - Highlights: • A new method for estimating H{sup ⁎}(10) using prompt gamma emissions from HDPE. • Linear combination of 2.2 MeV and 4.4 MeV gamma intensities approximates DCC (ICRP). • Feasibility of the method was established theoretically and experimentally. • The response of the present technique is very similar to that of the rem meters.

  16. Designing an Epithermal Neutron Beam for Boron Neutron Capture Therapy for the Fusion Reactions 2H(d,n)3He and 3H(d,n)4He1

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Costes, S.V.; Bleuel, D.; Vujic, J.; Leung, K.N.

    1998-01-01

    A beam shaping assembly has been designed to moderate high energy neutrons from the fusion reactions 2 H(d,N) 3 He and 3 H(d,n) 4 He for use fin boron neutron capture therapy. The low neutron yield of the 2 H(d,n) 3 He reaction led to unacceptably long treatment times. However, a 160 mA deuteron beam of energy 400 keV led to a treatment time of 120 minutes with the reaction 3 H(d,n) 4 He. Equivalent doses of 9.6 Gy-Eq and 21.9 Gy-Eq to the skin and to a 8 cm deep tumor respectively have been computed

  17. Construction of 144, 565 keV and 5.0 MeV monoenergetic neutron calibration fields at JAERI.

    Science.gov (United States)

    Tanimura, Y; Yoshizawa, M; Saegusa, J; Fujii, K; Shimizu, S; Yoshida, M; Shibata, Y; Uritani, A; Kudo, K

    2004-01-01

    Monoenergetic neutron calibration fields of 144, 565 keV and 5.0 MeV have been developed at the Facility of Radiation Standards of JAERI using a 4 MV Pelletron accelerator. The 7Li(p,n)7Be and 2H(d,n)3He reactions are employed for neutron production. The neutron energy was measured by the time-of-flight method with a liquid scintillation detector and calculated with the MCNP-ANT code. A long counter is employed as a neutron monitor because of the flat response. The monitor is set up where the influence of inscattered neutrons from devices and their supporting materials at a calibration point is as small as possible. The calibration coefficients from the monitor counts to the neutron fluence at a calibration point were obtained from the reference fluence measured with the transfer instrument of the primary standard laboratory (AIST), a 24.13 cm phi Bonner sphere counter. The traceability of the fields to AIST was established through the calibration.

  18. Dosimetric response evaluation of tooth enamel for accelerator-based neutron radiation

    International Nuclear Information System (INIS)

    Khan, R.F.H.; Rink, W.J.; Boreham, D.R.

    2003-01-01

    To study the neutron response of human tooth enamel, a number of experiments with an accelerator-based neutron source have been designed. The neutron beam was produced with the low gamma yield, 7 Li(p,n) 7 Be type thick target, using the 3 MV McMaster K.N. Van de Graaff accelerator. The dosimetry was done using a pre-calibrated snoopy type neutron dosimeter. Neutron irradiation induces a dosimetric signal in the tooth enamel at the same defect site as gamma produced damage with the same g-values (g parallel =1.9973, width 0.4 mT g perpendicular =2.002, width 0.3 mT). The dosimetric signal grows linearly with neutron dose from 6-35 Gy tissue dose. Dosimetric response in two different grain sizes (300-500 μm, and grains <4 mm) has shown increased dosimetric amplitude in the larger grains. Dose build up effect on tooth inside the mouth due to cheek was simulated by placing a 4 mm thick paraffin wax layer between the beam and tooth, but had little effect. These results show that for mean neutron energy of 280 keV, the relative neutron response of the human tooth enamel ranges from 8% to 12% of the equivalent gamma ray response

  19. Measurement of the MACS of {sup 181}Ta(n,γ) at kT=30 keV as a test of a method for Maxwellian neutron spectra generation

    Energy Technology Data Exchange (ETDEWEB)

    Praena, J., E-mail: jpraena@us.es [Universidad de Sevilla (Spain); Centro Nacional de Aceleradores, Sevilla (Spain); Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Padova (Italy); Pignatari, M. [Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Quesada, J.M. [Universidad de Sevilla (Spain); García-López, J. [Universidad de Sevilla (Spain); Centro Nacional de Aceleradores, Sevilla (Spain); Lozano, M. [Universidad de Sevilla (Spain); Dzysiuk, N. [International Nuclear Safety Center of Ukraine, Kyiv (Ukraine); Capote, R. [NAPC–Nuclear Data Section, International Atomic Energy Agency, Vienna (Austria); Martín-Hernández, G. [Centro de Aplicaciones Tecnólogicas y Desarrollo Nuclear, 5ta y 30, Playa, La Habana (Cuba)

    2013-11-01

    Measurement of the Maxwellian-Averaged Cross-Section (MACS) of the {sup 181}Ta(n,γ) reaction at kT=30 keV by the activation technique using an innovative method for the generation of Maxwellian neutron spectra is presented. The method is based on the shaping of the proton beam to produce a desired neutron spectrum using the {sup 7}Li(p,n) reaction as a neutron source. The characterization of neutron spectra has been performed by combining measured proton distributions, an analytical description of the differential neutron yield in angle and energy of the {sup 7}Li(p,n) reaction, and with Monte Carlo simulations of the neutron transport. A measured value equal to 815±73 mbarn is reported for the MACS of the reaction {sup 181}Ta(n,γ) at kT=30 keV. The MACS of the reaction {sup 197}Au(n,γ) provided by KADoNiS has been used as a reference. -- Author-Highlights: • Generation of Maxwellian neutron spectrum for astrophysics and nuclear data validation. • {sup 7}Li(p,n) reaction and proton distributions conformed by aluminum as a shaper foil. • Measurement of the proton distributions and simulation of the neutron transport. • MACS of {sup 181}Ta(n,γ) at kT=30 keV measured by the activation technique. • First accelerator-based neutron source in Spain.

  20. Dose and dose rate extrapolation factors for malignant and non-malignant health endpoints after exposure to gamma and neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Van; Little, Mark P. [National Cancer Institute, Radiation Epidemiology Branch, Rockville, MD (United States)

    2017-11-15

    Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and

  1. A comparison study on of tumor cell-killing effects between low-dose-rate β-irradiation of 32P and γ-irradiation of 60Co

    International Nuclear Information System (INIS)

    Feng Huiru; Tian Jiahe; Ding Weimin; Zhang Jinming; Chen Yingmao

    2004-01-01

    The paper is to elucidate radiobiological characteristics and radiobiological mechanism in killing tumor cells with low dose rate β-rays and high dose rate γ-rays. HeLa cells were exposed to low-rate β-irradiation of 32 P or high-dose-rate γ-irradiation of 60 Co. Cell response-patterns were compared between two the types of radiations in terms of their inhibition of cell proliferation and cell cycle blockage, evaluated by trypanblue excluded method and flow cytometry, respectively. Results show that there is a different way in growth inhibition effect on HeLa cells between low-dose-rate irradiation of 32 P and high-dose-rate irradiation of 60 Co γ. In exposure to 32 P, the inhibition of cell proliferation in HeLa cell was a prolong course, whereas and the effect was in a more serious and quick way in 60 Co irradiation. Cell cycle arrest in G 2 phase induced by 32 P was lower and more prolong than that induced by 60 Co. The inhibition effect on tumor cells between the two types of radiations is different. Impaired DNA repair system by continuous low-dose-rate radiation might contribute to the final radiation effect of 32 P

  2. Temperature dependence of the deformation behavior of 316 stainless steel after low temperature neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Pawel-Robertson, J.E.; Rowcliffe, A.F.; Grossbeck, M.L. [Oak Ridge National Lab., TN (United States)] [and others

    1996-10-01

    The effects of low temperature neutron irradiation on the tensile behavior of 316 stainless steel have been investigated. A single heat of solution annealed 316 was irradiated to 7 and 18 dpa at 60, 200, 330, and 400{degrees}C. The tensile properties as a function of dose and as a function of temperature were examined. Large changes in yield strength, deformation mode, strain to necking, and strain hardening capacity were seen in this irradiation experiment. The magnitudes of the changes are dependent on both irradiation temperature and neutron dose. Irradiation can more than triple the yield strength over the unirradiated value and decrease the strain to necking (STN) to less than 0.5% under certain conditions. A maximum increase in yield strength and a minimum in the STN occur after irradiation at 330{degrees}C but the failure mode remains ductile.

  3. First experiments with a liquid-lithium based high-intensity 25-keV neutron source

    International Nuclear Information System (INIS)

    Paul, M.

    2014-01-01

    A high-intensity neutron source based on a Liquid-Lithium Target (LiLiT) and the 7 Li(p,n) reaction was developed at SARAF (Soreq Applied Research Accelerator Facility, Israel) and is used for nuclear astrophysics experiments. The setup was commissioned with a 1.3 mA proton beam at 1.91 MeV, producing a neutron yield of ~ 2 ×10 10 n/s, more than one order of magnitude larger than conventional 7 Li(p,n)-based neutron sources and peaked at ~25 keV. The LiLiT device consists of a high-velocity (> 4 m/s) vertical jet of liquid lithium (~200 °C) whose free surface is bombarded by the proton beam. The lithium jet acts both as the neutron-producing target and as a power beam dump. The target dissipates a peak power areal density of 2.5 kW/cm 2 and peak volume density of 0.5 MW/cm 3 with no change of temperature or vacuum regime in the vacuum chamber. Preliminary results of Maxwellian-averaged cross section measurements for stable isotopes of Zr and Ce, performed by activation in the neutron flux of LiLiT, and nuclear-astrophysics experiments in planning will be described. (author)

  4. Neutron absorbed dose in a pacemaker CMOS

    International Nuclear Information System (INIS)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R.; Paredes G, L.

    2012-01-01

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10 -17 Gy per neutron emitted by the source. (Author)

  5. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: fermineutron@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-06-15

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10{sup -17} Gy per neutron emitted by the source. (Author)

  6. Neutron dosimeters and survey meters in accelerators, reactors and other neutron environments

    International Nuclear Information System (INIS)

    1989-03-01

    Neutron fields in occupationally accessible areas around nuclear reactors, radioisotope sources and medical and high energy accelerators have been characterized using currently available information. Neutron, rem meters, such as the Leake detector, are the most suitable instruments available for conducting neutron dose rate surveys in the vicinity of radioisotope neutron sources, nuclear reactors and medical accelerators. However, these instruments have been shown to be deficient in that they overrespond by a factor of four to neutrons in the 0.1 to 1 MeV range and are insensitive to neutrons from about 1 eV up to about 10 keV. Also, they are insensitive to neutrons above 20 MeV and their use must be restricted near high energy accelerators where significant numbers of neutrons above 20 MeV are known to be present. The most suitable instrument of measure dose from neutrons above 20 MeV is the 12 C(n,2n) 11 C scintillation chamber. Commercially available rem meters frequently use BF 3 counters in the pulse mode to detect thermal neutrons. Therefore, measurements around pulsed accelerators must be made with caution to ensure that the detector is not saturated during each pulse and that the accelerator pulse period is greater than the response time of the detector. The personal neutron dosimeters currently available either are known to be insensitive to neutrons above 20 MeV or have not been tested. Also, all except the albedo dosimeter are insensitive to or have not been tested for neutron energies in the range 1 eV to 10 keV. Several dosimeter types respond reasonably well to neutrons in the energy range 0.1 to 15 MeV, for example, CR-39, bubble and superheated drop detectors. However, the first gas a lower limit of sensitivity of about 0.3 mSv. The bubble detector can be designed to measure doses as small as 1μSv and offers the additional benefit of direct-reading capability. The superheated drop detector is not suitable for use around pulsed accelerators because

  7. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds

    International Nuclear Information System (INIS)

    Wiendl, Toni Andreas

    2010-01-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5 th leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  8. Relative biological effectiveness (RBE) of fission neutrons and gamma rays at occupational exposure levels: Volume 1, Studies on the genetic effects in mice of 60 equal once-weekly exposures to fission neutrons and gamma rays

    International Nuclear Information System (INIS)

    Grahn, D.; Carnes, B.A.

    1987-10-01

    The relative biological effectiveness (RBE) values for low doses of fission neutrons compared to 60 Co gamma rays were determined with four separate assessments of genetic damage induced in young hybrid male mice. Both radiations were delivered at low dose levels over about one-half the adult lifetime as 60 once-weekly exposures. Genetic damage assessed included both transient and residual injury. The latter is more critical, as residual genetic injury can be transmitted to subsequent generations long after the radiation exposures have ceased. Assays were performed periodically during the 60-week exposure period and at 10 or more weeks after the irradiations had terminated. RBE values, with few exceptions, ranged between 5 and 15 for transient injury and between 25 and 50 for different types of residual genetic injury. The most important form of residual genetic damage in this study was the balanced reciprocal chromosome translocation. These translocations continue to be transmitted throughout reproductive life and can lead to reduced fertility and increased prenatal mortality. The best estimate of the RBE value for translocations was 45 +- 10. Implications and recommendations with regard to the neutron quality factor will be presented conjointly with the findings from the data obtained in this same project on life shortening and on the risks of incidence or death from neoplastic disease. 64 refs., 23 tabs

  9. Method and apparatus for determining the dose value of neutrons

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Piesch, E.

    1976-01-01

    A method is provided for determining the dose value of neutrons leaving a body as thermal and intermediate neutrons after having been scattered in the body. A first dose value of thermal and intermediate neutrons is detected on the surface of the body by means of a first detector for neutrons which is shielded against thermal and intermediate neutrons not emerging from the body. A second detector is used to measure a second dose value of the thermal and intermediate neutrons not emerging from the body. A first correction factor based on the first and second values is obtained from a calibration diagram and is applied to the first dose value to determine a first corrected first dose value. 21 Claims, 6 Drawing Figures

  10. Measurement of the relationship of {sup 24} Na activity and the received neutron dose; Medicion de la relacion de la actividad de {sup 24}Na y la dosis de neutrones recibida

    Energy Technology Data Exchange (ETDEWEB)

    Gossio, S.; Carrelli, J.; Villella, A.; Soppe, E., E-mail: sgossio@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    In cases of criticality accidents it is required a fast dosimetric system that allows to evaluate the doses of the personnel involved. The reaction (n,y) with sodium presented in the body ({sup 23}Na), generates {sup 24}Na, that emits two gamma of 1369KeV and 2754 KeV that can be measured using a whole body counter. The experienced were carried out with the irradiation of {sup 252} Cf of a phantom with a solution of NaCl in water. After the irradiation it was measured the {sup 24}Na activity in the whole body counter, which has a HPGe detector previously calibrated in energy and efficiency. Considering the correction by decay, the quantity of {sup 23}Na presented in the body of an adult and elimination curve of {sup 24}Na, it was established a coefficient of neutronic doses by unity of activity of {sup 24}Na measured in the whole body counter. This method is useful for the retrospective estimation of the doses, as well as to carry out a radiological sorting in case of criticality.

  11. Neutron filters for producing monoenergetic neutron beams

    International Nuclear Information System (INIS)

    Harvey, J.A.; Hill, N.W.; Harvey, J.R.

    1982-01-01

    Neutron transmission measurements have been made on high-purity, highly-enriched samples of 58 Ni (99.9%), 60 Ni (99.7%), 64 Zn (97.9%) and 184 W (94.5%) to measure their neutron windows and to assess their potential usefulness for producing monoenergetic beams of intermediate energies from a reactor. Transmission measurements on the Los Alamos Sc filter (44.26 cm Sc and 1.0 cm Ti) have been made to determine the characteristics of the transmitted neutron beam and to measure the total cross section of Sc at the 2.0 keV minimum. When corrected for the Ti and impurities, a value of 0.35 +- 0.03 b was obtained for this minimum

  12. Thermal neutron dose calculation in synovium membrane for BNCS

    International Nuclear Information System (INIS)

    Abdalla, Khalid; Naqvi, A.A.; Maalej, N.; El-Shahat, B.

    2006-01-01

    A D(d,n) reaction based setup has been optimized for Boron Neutron Capture Synovectomy (BNCS). The polyethylene moderator and graphite reflector sizes were optimized to deliver the highest ratio of thermal to fast neutron yield. The neutron dose was calculated at various depths in a knee phantom loaded with boron to determine therapeutic ratios of synovium dose/skin dose and synovium dose/bone dose. Normalized to same boron loading in synovium, the values of the therapeutic ratios obtained in the present study are 12-30 times higher than the published values. (author)

  13. Fluence to Effective Dose and Effective Dose Equivalent Conversion Coefficients for Photons from 50 KeV to 10 GeV

    International Nuclear Information System (INIS)

    Ferrari, A.; Pelliccioni, M.; Pillon, M.

    1996-07-01

    Effective dose equivalent and effective dose per unit photon fluence have been calculated by the FLUKA code for various geometrical conditions of irradiation of an anthropomorphic phantom placed in a vacuum. Calculations have been performed for monoenergetic photons of energy ranging from 50 keV to 10 GeV. The agreement with the results of other authors, when existing, is generally very satisfactory

  14. Neutron cross section measurement using the Oak Ridge Electron Linear Accelerator

    International Nuclear Information System (INIS)

    Winters, R.R.

    1991-08-01

    This report discusses: argon-40 -- neutron reaction total cross sections from 6.9 kev to 50 kev; The maxwellian averaged neutron capture cross section of oxygen-16; r-matrix parameter analysis of the lead-208 -- neutron reaction cross section measurement; r-matrix parameter analysis of the ORELA neutron transmission zirconium-90 low energy measurement; porting computer codes from the HP9000 to the IBM RISC/6000;and measurements of neutron reactions with strontium-88, zirconium-90, and calcium-40

  15. Surface damage studies of ETFE polymer bombarded with low energy Si ions (≤100 keV)

    International Nuclear Information System (INIS)

    Minamisawa, Renato Amaral; Almeida, Adelaide De; Budak, Satilmis; Abidzina, Volha; Ila, Daryush

    2007-01-01

    Surface studies of ethylenetetrafluoroethylene (ETFE), bombarded with Si in a high-energy tandem Pelletron accelerator, have recently been reported. Si ion bombardment with a few MeV to a few hundred keV energies was shown to be sufficient to produce damage on ETFE film. We report here the use of a low energy implanter with Si ion energies lower than 100 keV, to induce changes on ETFE films. In order to determine the radiation damage, ETFE bombarded films were simulated with SRIM software and analyzed with optical absorption photometry (OAP), Raman and Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy to show quantitatively the physical and chemical property changes. Carbonization occurs following higher dose implantation, and hydroperoxides were formed following dehydroflorination of the polymer

  16. Phantom models for neutron capture therapy

    International Nuclear Information System (INIS)

    Storr, G.J.

    1990-08-01

    The development of a two-dimensional phantom model using the neutron and photon transport code DOT-IV is detailed. The effects of varying basic parameters such as aperture width, neutron source energy and tissue composition have been studied. One important conclusion from the study is that narrow beam apertures will give little or no advantage for tumour dose over tissue dose even in the 'ideal beam' range of 2-7 keV. The model may be used for future filter and beam studies with confidence. 10 refs., 7 tabs., 13 figs

  17. Dose prescription in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gupta, N.M.S.; Gahbauer, R.A.; Blue, T.E.; Wambersie, A.

    1994-01-01

    The purpose of this paper is to address some aspects of the many considerations that need to go into a dose prescription in boron neutron capture therapy (BNCT) for brain tumors; and to describe some methods to incorporate knowledge from animal studies and other experiments into the process of dose prescription. Previously, an algorithm to estimate the normal tissue tolerance to mixed high and low linear energy transfer radiations in BNCT was proposed. The authors have developed mathematical formulations and computational methods to represent this algorithm. Generalized models to fit the central axis dose rate components for an epithermal neutron field were also developed. These formulations and beam fitting models were programmed into spreadsheets to simulate two treatment techniques which are expected to be used in BNCT: a two-field bilateral scheme and a single-field treatment scheme. Parameters in these spreadsheets can be varied to represent the fractionation scheme used, the 10 B microdistribution in normal tissue, and the ratio of 10 B in tumor to normal tissue. Most of these factors have to be determined for a given neutron field and 10 B compound combination from large animal studies. The spreadsheets have been programmed to integrate all of the treatment-related information and calculate the location along the central axis where the normal tissue tolerance is exceeded first. This information is then used to compute the maximum treatment time allowable and the maximum tumor dose that may be delivered for a given BNCT treatment. The effect of different treatment variables on the treatment time and tumor dose has been shown to be very significant. It has also been shown that the location of D max shifts significantly, depending on some of the treatment variables-mainly the fractionation scheme used. These results further emphasize the fact that dose prescription in BNCT is very complicated and nonintuitive. 11 refs., 6 figs., 3 tabs

  18. Development of real time personal neutron dosimeter with two silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T.; Tsujimura, N. [Tohoku Univ., Cyclotron and Radioisotope Center, Aoba, Aramaki, Aoba-ku (Japan); Yamano, T. [Tokyo Factory, Fuji Electric Co. Ltd., Tokyo (Japan)

    1992-07-01

    We developed a real time personal neutron dosimeter by using two types of silicon p-n junction detectors, thermal neutron sensor and fast neutron sensor. The thermal neutron sensor which is {sup 10}B doped n-type silicon with a polyethylene radiator mainly counts neutrons of energy front thermal to I MeV, and the fast neutron sensor which is p-type silicon with a polyethylene radiator is sensitive to neutrons above I MeV. The neutron sensitivity measurements revealed that the dosimeter has a rather flat response for dose equivalent from thermal to 15 MeV, excluding a drop from 50 keV to I MeV. In order to get conversion factor from counts to dose equivalent as accurately as possible, we performed the field test of the dosimeter calibration in several neutron-generating fields. By introducing the two-group dose estimation method, this dosimeter can give the neutron dose equivalent within about 50% errors. (author)

  19. Cell death following thermal neutron exposure

    Energy Technology Data Exchange (ETDEWEB)

    Paterson, L.C. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Atanackovic, J. [Ontario Power Generation, Toronto, Ontario (Canada); Boyer, C. [Canadian Neutron Beam Centre, Chalk River, Ontario (Canada); El-Jaby, S.; Priest, N.D. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Seymour, C.B.; Boreham, D.R. [McMaster Univ., Hamilton, Ontario (Canada); Richardson, R.B. [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2014-07-01

    When individuals are exposed to unknown external ionizing radiation, it is desirable to have the means to assess both the absorbed dose received (Gy) and the radiation quality. Yet, conventional biodosimetry techniques, specifically the dicentric chromosome assay, cannot differentiate between the damage caused by high- and low-linear energy transfer (LET) exposures. Frequencies of apoptosis and necrosis, may provide an alternative method that assesses both the absorbed dose and radiation quality after unknown exposures. For this preliminary study, human lymphocytes were irradiated with {sup 60}Co gamma rays and thermal neutrons. Both apoptosis and necrosis increased with increasing gamma dose. In contrast, no dose-response was observed following thermal neutron exposure at doses up to 2.61 Gy. (author)

  20. Neutron fluence-to-dose conversion coefficients for embryo and fetus

    International Nuclear Information System (INIS)

    Chen, J.; Meyerhof, D.; Vlahovich, S.

    2004-01-01

    A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus. (authors)

  1. Neutron fluence-to-dose conversion coefficients for embryo and fetus.

    Science.gov (United States)

    Chen, Jing; Meyerhof, Dorothy; Vlahovich, Slavica

    2004-01-01

    A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus.

  2. Intermediate and fast neutron absorbed doses in fast neutron field at the RB reactor

    International Nuclear Information System (INIS)

    Sokcic-Kostic, M.; Pesic, M.; Antic, D.

    1987-10-01

    The experimental fuel channel EFC is created as one of the fast neutron fields at the RB reactor. The intermediate and fast neutron spectra in EFC are measured by activation technique. The intermediate and fast neutron absorbed doses are computed on the basis of these experimental results. At the end the obtained doses are compared. (author)

  3. Advanced Computational Approaches for Characterizing Stochastic Cellular Responses to Low Dose, Low Dose Rate Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Bobby, R., Ph.D.

    2003-06-27

    -LET radiation). Such phantom risks also may arise from risk assessments conducted for combined exposure to low- and high-LET radiations when based on the LNT or other models that exclude RR < 1. Our results for high-LET radiation are consistent with the LNT hypothesis but only where there is no additional low-LET contribution (e.g., gamma rays) to the total dose. For high-LET neutron sources, gamma rays arise (especially in vivo) for large mammals such as humans from neutron interactions with tissue. The gamma rays might provide some protection from low-dose-related stochastic effects via inducing the protective bystander apoptosis effect that is considered to contribute to tissue cleansing via removal of problematic cells.

  4. Fast Neutron Radiative Capture Cross Sections for some Important Standards from 30 keV to 1.5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, J

    1971-12-15

    Neutron capture radiative cross sections for Ta, Ag, In and Au have been measured between 30 keV and 1.5 MeV using time-of-flight technique. The detector used was a large liquid scintillator. Cross sections are given in relative and absolute units

  5. Fast Neutron Radiative Capture Cross Sections for some Important Standards from 30 keV to 1.5 MeV

    International Nuclear Information System (INIS)

    Hellstroem, J.

    1971-12-01

    Neutron capture radiative cross sections for Ta, Ag, In and Au have been measured between 30 keV and 1.5 MeV using time-of-flight technique. The detector used was a large liquid scintillator. Cross sections are given in relative and absolute units

  6. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  7. Effect of low dose irradiation of 60Co γ-rays on seed germination, seedling growth and enzymes activity of Lactuca sativa

    International Nuclear Information System (INIS)

    Liu Xiuqing; Zhang Tie

    2012-01-01

    The seeds of Lactuca sativa were irradiated by different doses (10, 20, 30, 40, 50 Gy) of 60 Co γ-rays. The effects of low dose irradiation on seed germination, seedling growth and enzymes activity were investigated. The results indicated that low dose irradiation could promote germination rate, germinating viability, germination rate in the field, root length and height of seedling. The suitable dosage for low dose irradiation for Lactuca sativa was 30 Gy. POD activity after irradiation treatment in the range of 10 to 50 Gy and CAT activity after irradiation treatment in the range of 20 Gy to 40 Gy was lower than that of control. (authors)

  8. Neutron resonance transmission spectroscopy with high spatial and energy resolution at the J-PARC pulsed neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [University of California at Berkeley, 7 Gauss Way, Berkeley, CA 94720 (United States); Shinohara, T.; Kai, T.; Ooi, M. [Japan Atomic Energy Agency, 2–4 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Kamiyama, T.; Kiyanagi, Y.; Shiota, Y. [Hokkaido University, Kita 13 Nishi 8 Kita-ku, Sapporo-shi, Hokkaido 060-8628 (Japan); McPhate, J.B.; Vallerga, J.V.; Siegmund, O.H.W. [University of California at Berkeley, 7 Gauss Way, Berkeley, CA 94720 (United States); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Rd., Sturbridge, MA 01566 (United States)

    2014-05-11

    The sharp variation of neutron attenuation at certain energies specific to particular nuclides (the lower range being from ∼1 eV up to ∼1 keV), can be exploited for the remote mapping of element and/or isotope distributions, as well as temperature probing, within relatively thick samples. Intense pulsed neutron beam-lines at spallation sources combined with a high spatial, high-timing resolution neutron counting detector, provide a unique opportunity to measure neutron transmission spectra through the time-of-flight technique. We present the results of experiments where spatially resolved neutron resonances were measured, at energies up to 50 keV. These experiments were performed with the intense flux low background NOBORU neutron beamline at the J-PARC neutron source and the high timing resolution (∼20 ns at epithermal neutron energies) and spatial resolution (∼55 µm) neutron counting detector using microchannel plates coupled to a Timepix electronic readout. Simultaneous element-specific imaging was carried out for several materials, at a spatial resolution of ∼150 µm. The high timing resolution of our detector combined with the low background beamline, also enabled characterization of the neutron pulse itself – specifically its pulse width, which varies with neutron energy. The results of our measurements are in good agreement with the predicted results for the double pulse structure of the J-PARC facility, which provides two 100 ns-wide proton pulses separated by 600 ns, broadened by the neutron energy moderation process. Thermal neutron radiography can be conducted simultaneously with resonance transmission spectroscopy, and can reveal the internal structure of the samples. The transmission spectra measured in our experiments demonstrate the feasibility of mapping elemental distributions using this non-destructive technique, for those elements (and in certain cases, specific isotopes), which have resonance energies below a few keV, and with lower

  9. Calculation of fast neutron dose in plastic-coated optical fibers

    International Nuclear Information System (INIS)

    Siebert, B.R.L.; Henschel, H.

    1998-01-01

    The dose of fast neutrons in optical fibers with hydrogen-containing coating materials is considerably increased by energetic recoil protons. Their contribution to the dose in a SiO 2 fiber core is calculated by the Monte Carlo method for different fiber geometries and a fiber optic cable. With 14 MeV neutrons the dose in a single fiber is increased by about 21%, whereas in fiber bundles the dose increase can reach about 170%. Maximum dose enhancement in fiber bundles (about 610%) occurs at neutron energies around 5.5 MeV. The dose increase caused by 14 MeV neutrons in the fiber of a typical laboratory cable is about 124%

  10. Characterization of the neutron irradiation system for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories.

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Manuel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-08-01

    The objective of this work was to characterize the neutron irradiation system consisting of americium-241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three recycled 241AmBe sources of different activities that had been combined into a single source. The source in its polyethylene shielding will be used in neutron irradiation testing of components. The characterization of the source-shielding system was necessary to evaluate the radiation environment for future experiments. Characterization of the source was also necessary because the documentation for the three component sources and their relative alignment within the Special Form Capsule (SFC) was inadequate. The system consisting of the source and shielding was modeled using Monte Carlo N-Particle transport code (MCNP). The model was validated by benchmarking it against measurements using multiple techniques. To characterize the radiation fields over the full spatial geometry of the irradiation system, it was necessary to use a number of instruments of varying sensitivities. First, the computed photon radiography assisted in determining orientation of the component sources. With the capsule properly oriented inside the shielding, the neutron spectra were measured using a variety of techniques. A N-probe Microspec and a neutron Bubble Dosimeter Spectrometer (BDS) set were used to characterize the neutron spectra/field in several locations. In the third technique, neutron foil activation was used to ascertain the neutron spectra. A high purity germanium (HPGe) detector was used to characterize the photon spectrum. The experimentally measured spectra and the MCNP results compared well. Once the MCNP model was validated to an adequate level of confidence, parametric analyses was performed on the model to optimize for potential

  11. Photon and neutron dose discrimination using low pressure proportional counters with graphite and A150 walls

    International Nuclear Information System (INIS)

    Kylloenen, J.; Lindborg, L.

    2005-01-01

    Full text: The determination of both the low- and high-LET components of ambient dose equivalent in mixed fields is possible with microdosimetric methods. With the multiple-event microdosimetric variance covariance method the sum of those components are directly obtained also in pulsed beams. However, if the value of each dose component is needed a more extended analysis is required. The use of a graphite walled proportional detector in combination with a tissue-equivalent proportional counter in combination with the variance covariance method was here investigated. MCNP simulations were carried out for relevant energies to investigate the photon and neutron responses of the two detectors. The combined graphite and TEPC system, the Sievert instrument, was used for measurements at IRSN, Cadarache, in the workplace calibration fields of CANEL+, SIGMA, a Cf-252 and a moderated Cf(D 2 O,Cd) radiation field. The response of the instrument in various monoenergetic neutron fields is also known from measurements at PTB. The instrument took part in the measurement campaigns in workplace fields in the nuclear industry organized within the EVIDOS contract. The results are analyzed and the method of using a graphite detector compared with alternative methods of analysis is discussed. (author)

  12. Cross section measurements of the 10B(d,n0)11C reaction below 160 keV

    International Nuclear Information System (INIS)

    Stave, S.; Ahmed, M. W.; Blackston, M. A.; Crowell, A. S.; Henshaw, S. S.; Howell, C. R.; Kingsberry, P.; Perdue, B. A.; Weller, H. R.; Antolak, A. J.; Doyle, B. L.; Rossi, P.; Prior, R. M.; Spraker, M. C.

    2008-01-01

    New data were taken at the Triangle Universities Nuclear Laboratory to investigate the plausibility of using low energy deuterons and the 10 B(d,n) 11 C reaction as a portable source of 6.3 MeV neutrons. Analysis of the data at and below incident deuteron energies of 160 keV indicates an n 0 neutron cross section that is lower than previous estimates by at least three orders of magnitude. In separate runs, deuterons with two different energies (160 and 140 keV) were stopped in a 10 B target. The resulting n 0 neutrons of approximately 6.3 MeV were detected at angles between 0 deg. and 150 deg. The angle integrated yields were used to determine the astrophysical S factor for this reaction assuming a constant value for the S factor below 160 keV. The cross sections reported between 130 and 160 keV were calculated using the extracted value of the S factor. The measured n 0 cross section is several orders of magnitude smaller than previous results, thus eliminating 10 B(d,n) 11 C as a portable source of intense neutrons with low energy deuteron beams on the order of tens of microamps. In order to gain insight into the reaction dynamics at these low energies the cross section results have been compared with results from calculations using the distorted wave Born approximation (DWBA) and a detailed Hauser-Feshbach calculation performed by the authors. The angular distribution is consistent with the Hauser-Feshbach calculation suggesting a statistical compound nucleus reaction rather than a direct reaction

  13. Development of a neutron personal dose equivalent detector

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.; Momose, T.; Nunomiya, T.; Aoyama, K.

    2007-01-01

    A new neutron-measuring instrument that is intended to measure a neutron personal dose equivalent, H p (10) was developed. This instrument is composed of two parts: (1) a conventional moderator-based neutron dose equivalent meter and (2) a neutron shield made of borated polyethylene, which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics that would generally match both the energy and angular dependencies of H p (10). This new instrument will be a great help in assessing the reference values of neutron H p (10) during field testing of personal neutron dosemeters in workplaces and also in interpreting their readings. (authors)

  14. Estimate of absorbed dose received by individuals irradiated with neutrons

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Mauricio, C.L.P.

    1995-01-01

    An innovating methodology is proposed to estimate the absorbed dose received by individuals irradiated with neutrons in an accident, even in the case that the victim is not using any kind of neutron dosemeter. The method combines direct measurements of 24 Na and 32 P activated in the human body. The calculation method was developed using data taken from previously published papers and experimental measurements. Other irradiations results in different neutron spectra prove the validity of the methodology here proposed. Using a whole body counter to measure 24 Na activity, it is possible to evaluate neutron absorbed doses in the order of 140 μGy of very soft (thermal) spectra. For fast neutron fields, the lower limit for neutron dose detection increases, but the present method continues to be very useful in accidents, with higher neutron doses. (author). 5 refs., 1 fig., 4 tabs

  15. Monte Carlo calculations of lung dose in ORNL phantom for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Krstic, D.; Markovic, V.M.; Jovanovic, Z.; Milenkovic, B.; Nikezic, D.; Atanackovic, J.

    2014-01-01

    Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations. The difference in evaluated dose in cancer and normal lung tissue suggests that BNCT could be applied for the treatment of cancers. The difference in exposure of cancer and healthy tissue can be observed, so the healthy tissue can be spared from damage. An absorbed dose ratio of metastatic tissue-to-the healthy tissue was ∼5. Absorbed dose to all other organs was low when compared with the lung dose. Absorbed dose depth distribution shows that BNC therapy can be very useful in the treatments for tumour. The ratio of the tumour absorbed dose and irradiated healthy tissue absorbed dose was also ∼5. It was seen that an elliptical neutron field was better irradiation choice. (authors)

  16. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C. Y.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: candy_borja@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    The absorbed dose due to neutrons by a Complementary Metal Oxide Semiconductor (CMOS) has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes a patient that must be treated by radiotherapy with a linear accelerator; the pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. When the Linac is working in Bremsstrahlung mode an undesirable neutron field is produced due to photoneutron reactions; these neutrons could damage the CMOS putting the patient at risk during the radiotherapy treatment. In order to estimate the neutron dose in the CMOS a Monte Carlo calculation was carried out where a full radiotherapy vault room was modeled with a W-made spherical shell in whose center was located the source term of photoneutrons produced by a Linac head operating in Bremsstrahlung mode at 18 MV. In the calculations a phantom made of tissue equivalent was modeled while a beam of photoneutrons was applied on the phantom prostatic region using a field of 10 x 10 cm{sup 2}. During simulation neutrons were isotropically transported from the Linac head to the phantom chest, here a 1 {theta} x 1 cm{sup 2} cylinder made of polystyrene was modeled as the CMOS, where the neutron spectrum and the absorbed dose were estimated. Main damages to CMOS are by protons produced during neutron collisions protective cover made of H-rich materials, here the neutron spectrum that reach the CMOS was calculated showing a small peak around 0.1 MeV and a larger peak in the thermal region, both connected through epithermal neutrons. (Author)

  17. Influence of Neutron Spectra Unfolding Method on Fast Neutron Dose Determination

    International Nuclear Information System (INIS)

    Marinkovic, P.

    1991-01-01

    Full text: Accuracy of knowing the fast neutron spectra has great influence on equivalent dose determination. In usual fast neutron spectrum measurements with scintillation detectors based on proton recoil, the main difficulty is confidence of unfolding method. In former ones variance of obtained result is usually great and negative values are possible too, which does means that we don't now exactly is obtained neutron spectrum real one. The new unfolding method based on Shanon's information theory, which gives non-negative spectrum and relative low variance, is obtained and appropriate numerical code for application in fast neutron spectrometry based on proton recoil is realized. In this method principle of maximum entropy and maximum likelihood are used together. Unknown group density distribution functions, which are considered as desired normalized mean neutron group flux, are constl u cted using only constrain of knowing mean value. Obtained distributions are consistent to available information (counts in NCA from proton recoil), while being maximally noncommittal with respect to all other unknown circumstances. For maximum likelihood principle, distribution functions around mean value of counts in the channels of MCA are taken to be Gauss function shape. Optimal non-negative solution is searched by means of Lagrange parameter method. Nonlinear system of equations, is solved using gradient and Newton iterative algorithm. Error covariance matrix is obtained too. (author)

  18. SU-E-T-611: Photon and Neutron Peripheral Dose Ratio for Low (6 MV) and High (15 MV) Energy for Treatment Selection

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L; Sanchez-Doblado, F [Departamento de Fisiologia Medica y Biofisica, Universidad de Seville (Spain); Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville (Spain); Terron, J; Ortiz-Seidel, M [Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville (Spain); Departamento de Fisiologia Medica y Biofisica, Universidad de Seville (Spain); Sanchez-Nieto, B [Instituto de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile)

    2015-06-15

    Purpose: Differences between radiotherapy techniques and energies, can offer improvements in tumor coverage and organs at risk preservation. However, a more complete decision should include peripheral doses delivered to the patient. The purpose of this work is the balance of photon and neutron peripheral doses for a prostate case solved with 6 different treatment modalities. Methods: Inverse and Forward IMRT and 3D-CRT in 6 and 15 MV for a Siemens Primus linac, using the same CT data set and contours. The methodology described in [1], was used with the TNRD thermal neutron detector [2] for neutron peripheral dose estimation at 7 relevant organs (colon, esophagus, stomach, liver, lung, thyroid and skin). Photon doses were estimated for these organs by terms of the algorithm proposed in [3]. Plans were optimized with the same restrictions and limited to 30 segments in the Inverse case. Results: A similar photon peripheral dose was found comparing 6 and 15 MV cases with slightly higher values of (1.9 ± 1.6) % in mean, for the 6 MV cases. Neutron presence when using 15 MV, represents an increase in peripheral dose of (18 ± 17) % in average. Due to the higher number of MU used in Inverse IMRT, an increasing of (22 ± 3) % in neutron dose is found related to Forward and 3D-CRT plans. This corresponds to photon doses within 44 and 255 mSv along the organs, for a dose prescription of 68 Gy at the isocenter. Conclusion: Neutron and photon peripheral doses for a prostate treatment planified in 6 different techniques have been analyzed. 6 MV plans are slightly more demanding in terms of photon peripheral doses. Inverse technique in 15 MV has Result to be the most demanding one in terms of total peripheral doses, including neutrons and photons.

  19. Fast Neutron Dose Distribution in a Linac Radiotherapy Facility

    International Nuclear Information System (INIS)

    Al-Othmany, D.Sh.; Abdul-Majid, S.; Kadi, M.W.

    2011-01-01

    CR-39 plastic detectors were used for fast neutron dose mapping in the radiotherapy facility at King AbdulAziz University Hospital (KAUH). Detectors were calibrated using a 252 Cf neutron source and a neutron dosimeter. After exposure chemical etching was performed using 6N NaOH solution at 70 degree C. Tracks were counted using an optical microscope and the number of tracks/cm 2 was converted to a neutron dose. 15 track detectors were distributed inside and outside the therapy room and were left for 32 days. The average neutron doses were 142.3 mSv on the accelerator head, 28.5 mSv on inside walls, 1.4 mSv beyond the beam shield, and 1 mSv in the control room

  20. Fast neutron detection with germanium detectors: computation of response functions for the 692 keV inelastic scattering peak

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Meckbach, R.; Paretzke, H.G.

    1996-01-01

    The dependence of the shape of the right-sided broadening of the inelastic scattering peak at 692 keV in the pulse-height distribution measured with a Ge detector in fast neutron fields on the energy of the incident neutrons has been analyzed. A model incorporating the process contributing to the energy deposition that engender the peak, including the partitioning of the energy deposition by the Ge recoils, was developed. With a Monte Carlo code based on this model, the detector response associated with this peak was computed and compared with results of measurements with quasi-monoenergetic neutrons for energies between 0.88 and 2.1 MeV. A set of 80 response functions for neutron energies in the range from the reaction threshold at 0.7 to 6 MeV was computed, which will serve as a starting point for methods, which aim at obtaining information on the spectral distribution of fast neutron fields for this energy range from measurements with a Ge detector. (orig.)

  1. Neutron dose to patients treated with high-energy medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.

    2001-01-01

    The neutron dose equivalent received by patients treated with high energy x-ray beams was measured in this research. A total of 13 different medical accelerators were evaluated in terms of the neutron dose equivalent in the patient plane and at the beam center. The neutron dose equivalent at the beam center was found to ranged from 0.02 to 9.4 mSv per Sv of x-ray dose and values from 0.029 to 2.58 mSv per Sv of x-ray were measured in the patient plane. It was concluded that the neutron levels meet the International Electrotechnical Commission standard for the patient plane. It was also concluded that when intensity modulated radiation treatment is conducted the neutron dose equivalent received by the patient will increase by a factor of 2 to 10. (author)

  2. Regularities in dose field formation for fixation of 252Cf and 60Co sources on the same plane

    International Nuclear Information System (INIS)

    Ivanov, V.N.; Vtyurin, B.M.; Ivanova, L.F.; Kondzhariya, Yu.R.

    1983-01-01

    A computerized study was made of a change in the correlation between the sizes of an irradiated volume and the distribution of sources. Criteria have been established for the utilization of 252 Cf and 60 Co sources of different active length and design placed on the same plane. Reference dose rate and its derivatives have been chosen as the main parameters that characterize a dose field. A dosimetric analysis was performed using the data for an adsorbed dose of neutrons in the tissue, taking account of high RBE of 252 Cf fast neutrons that equals 6-7, and a slight change of the local RBE value near the source resulting from a change of the effective spectrum of neutrons in combination with the growth of a contribution of #betta#-radiation into the summary dose with the removal from the source. The irradiated volume was evaluated by introducing 3 linear parameters - length, thickness and width. It has been shown that the ratio of the length of an irradiated volume to the active length of 252 Cf sources with radionuclide regular linear density changes from 0.7 with the isodose value of 85% up to 0.97 with the isodose value of 60%. For 60 Co sources with a higher linear density of the radionuclide on the edges the lower limit of this value equals 1. Intervals of changes in the rest of parameters have also been defined. The results obtained are presented graphically. The results of the study are used for a dosimetric control of the clinical trials of 252 Cf and 60 Co sources in the treatment of patients with tumors of the tongue, oral cavity fundus, lip and other sites

  3. Design of filtered epithermal neutron beams for BNC

    International Nuclear Information System (INIS)

    Greenwood, R.C.

    1986-01-01

    The design principles of filters (installed in nuclear reactors) to provide epithermal neutron beams suitable for use in 10 B Neutron Capture Therapy (BNCT) are reviewed. The goal of such filters is to provide epithermal neutron beams within an energy range of 1 keV to 30 keV with fluxes in excess of 5 x 10 8 neutrons/cm 2 .s, and having acceptably low contaminant fast neutron (> 30 keV) and gamma components. Filters considered for this application include 238 U, Sc, Fe/Al and Al/S. It is shown that in order to achieve a goal epithermal neutron flux of > 5 x 10 8 neutrons/cm 2 .s, such filters must be located in radial beam channels which view essentially the complete reactor core. Based on considerations of estimated epithermal fluxes, cost and availability of materials, and transmitted neutron energy spectrum, it is suggested that a filter consisting of elements of Al, S, Ti and V might prove to be an optimum design for BNCT applications. 13 references, 3 figures, 8 tables

  4. Spectral effects in low-dose fission and fusion neutron irradiated metals and alloys

    International Nuclear Information System (INIS)

    Heinisch, H.L.; Atkin, S.D.; Martinez, C.

    1986-04-01

    Flat miniature tensile specimens were irradiated to neutron fluences up to 9 x 10 22 n/m 2 in the RTNS-II and in the Omega West Reactor. Specimen temperatures were the same in both environments, with runs being made at both 90 0 C and 290 0 C. The results of tensile tests on AISI 316 stainless steel, A302B pressure vessel steel and pure copper are reported here. The radiation-induced changes in yield strength as a function of neutron dose in each spectrum are compared. The data for 316 stainless steel correlate well on the basis of displacements per atom (dpa), while those for copper and A302B do not. In copper the ratio of fission dpa to 14 MeV neutron dpa for a given yield stress change is about three to one. In A302B pressure vessel steel this ratio is more than three at lower fluences, but the yield stress data for fission and 14 MeV neutron-irradiated A302B steel appears to coalesce or intersect at the higher fluences

  5. The Bristol University neutron dosimetry system

    International Nuclear Information System (INIS)

    Worley, A.; Fews, A.P.; Henshaw, D.L.

    1987-01-01

    The neutron dosimetry system developed at Bristol is based on recording recoil proton tracks in conventionally etched PADC plastic using a fully automated image analysis system. Two features contribute to the achievement of a low dose threshold: high quality plastic is manufactured and undergoes extensive quality control tests prior to acceptance for use in dosimetry, and a readout system with high efficiency for rejecting background events is used. The principal dosemeter that has been developed consists of three orthogonal elements, each containing two 3 cm x 1 cm plastics on either side of a polyethylene radiator. On each plastic an area of 0.15 cm 2 is scanned giving a total active area of 0.90 cm 2 . Each plastic is coded for manual identification and for computer recognition. The track counts from the six plastics are added with different weightings to achieve a measure of dose which is independent of irradiation direction when worn on the body. The device has been calibrated using monoenergetic neutrons in the range 100 keV to 14.7 MeV at NPL, and using the recent CENDOS exposure. If the track counts are added without weighting, the device has a nominal response of 120 tracks cm -2 .mSv -1 and an energy threshold at 200 keV. Taken together with a background of 20 track cm -2 , a dose threshold of around 80μSv is implied. A simpler dosemeter, using a single plastic/radiator combination, may also be considered. If a 1 cm 2 device is used for normal incidence exposure, the dose threshold is calculated to be 25 μSv. (author)

  6. low dose irradiation growth in zirconium

    International Nuclear Information System (INIS)

    Fortis, A.M.

    1987-01-01

    Low dose neutron irradiation growth in textured and recrystallized zirconium, is studied, at the Candu Reactors Calandria temperature (340 K) and at 77 K. It was necessary to design and build 1: A facility to irradiate at high temperatures, which was installed in the Argentine Atomic Energy Commission's RA1 Reactor; 2: Devices to carry out thermal recoveries, and 3: Devices for 'in situ' measurements of dimensional changes. The first growth kinetics curves were obtained at 365 K and at 77 K in a cryostat under neutron fluxes of similar spectra. Irradiation growth experiments were made in zirconium doped with fissionable material (0,1 at % 235 U). In this way an equivalent dose two orders of magnitude greater than the reactor's fast neutrons dose was obtained, significantly reducing the irradiation time. The specimens used were bimetallic couples, thus obtaining a great accuracy in the measurements. The results allow to determine that the dislocation loops are the main cause of irradiation growth in recrystallized zirconium. Furthermore, it is shown the importance of 'in situ' measurements as a way to avoid the effect that temperature changes have in the final growth measurement; since they can modify the residual stresses and the overconcentrations of defects. (M.E.L.) [es

  7. Out‐of‐field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators

    Science.gov (United States)

    Cardenas, Carlos E.; Nitsch, Paige L.; Kudchadker, Rajat J.; Howell, Rebecca M.

    2016-01-01

    Out‐of‐field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high‐energy electron beams. To better understand the extent of these exposures, we measured out‐of‐field dose characteristics of electron applicators for high‐energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out‐of‐field dose profiles and percent depth‐dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out‐of‐field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out‐of‐field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central‐axis, which was found to be higher than typical out‐of‐field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for

  8. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

    Science.gov (United States)

    Cardenas, Carlos E; Nitsch, Paige L; Kudchadker, Rajat J; Howell, Rebecca M; Kry, Stephen F

    2016-07-08

    Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases.

  9. Neutron induced bystander effect among zebrafish embryos

    Science.gov (United States)

    Ng, C. Y. P.; Kong, E. Y.; Kobayashi, A.; Suya, N.; Uchihori, Y.; Cheng, S. H.; Konishi, T.; Yu, K. N.

    2015-12-01

    The present paper reported the first-ever observation of neutron induced bystander effect (NIBE) using zebrafish (Danio rerio) embryos as the in vivo model. The neutron exposure in the present work was provided by the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility at the National Institute of Radiological Sciences (NIRS), Chiba, Japan. Two different strategies were employed to induce NIBE, namely, through directly partnering and through medium transfer. Both results agreed with a neutron-dose window (20-50 mGy) which could induce NIBE. The lower dose limit corresponded to the threshold amount of neutron-induced damages to trigger significant bystander signals, while the upper limit corresponded to the onset of gamma-ray hormesis which could mitigate the neutron-induced damages and thereby suppress the bystander signals. Failures to observe NIBE in previous studies were due to using neutron doses outside the dose-window. Strategies to enhance the chance of observing NIBE included (1) use of a mono-energetic high-energy (e.g., between 100 keV and 2 MeV) neutron source, and (2) use of a neutron source with a small gamma-ray contamination. It appeared that the NASBEE facility used in the present study fulfilled both conditions, and was thus ideal for triggering NIBE.

  10. Application of the associated particle method to the determination of the efficiency of an NE 213 detection assembly with 750 keV neutrons. Utilization of a velocity filter

    International Nuclear Information System (INIS)

    Becret, Claude.

    1979-01-01

    This report presents the calibration of a neutron detection set, fitted with an NE 213 organic scintillator. This calibration uses the associated particle method, by means of the 3 T(p,n) 3 He reaction producing 750 keV neutrons. A separator device, of the velocity filter type, is employed for separating the heliums -emitted during the 3 T(p,n) 3 He neutron generating reaction- from the charged particles emanating from competing or spurious reactions. The calibration of this set enables neutron fluences of between 700 keV and 1 MeV in energy to be determined. The knowledge of such fluences is essential for dosimetry studies and for determining the sensitivity of weapons systems or components to nuclear radiation effects [fr

  11. Peripheral photon and neutron doses from prostate cancer external beam irradiation.

    Science.gov (United States)

    Bezak, Eva; Takam, Rundgham; Marcu, Loredana G

    2015-12-01

    Peripheral photon and neutron doses from external beam radiotherapy (EBRT) are associated with increased risk of carcinogenesis in the out-of-field organs; thus, dose estimations of secondary radiation are imperative. Peripheral photon and neutron doses from EBRT of prostate carcinoma were measured in Rando phantom. (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescence dosemeters (TLDs) were inserted in slices of a Rando phantom followed by exposure to 80 Gy with 18-MV photon four-field 3D-CRT technique. The TLDs were calibrated using 6- and 18-MV X-ray beam. Neutron dose equivalents measured with CR-39 etch-track detectors were used to derive readout-to-neutron dose conversion factor for (6)LiF:Mg,Cu,P TLDs. Average neutron dose equivalents per 1 Gy of isocentre dose were 3.8±0.9 mSv Gy(-1) for thyroid and 7.0±5.4 mSv Gy(-1) for colon. For photons, the average dose equivalents per 1 Gy of isocentre dose were 0.2±0.1 mSv Gy(-1) for thyroid and 8.1±9.7 mSv Gy(-1) for colon. Paired (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P TLDs can be used to measure photon and neutron doses simultaneously. Organs in close proximity to target received larger doses from photons than those from neutrons whereas distally located organs received higher neutron versus photon dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Monochromatic x-rays for low-dose digital mammography: preliminary results.

    Science.gov (United States)

    Yoon, Kwon-Ha; Kwon, Young Man; Choi, Byoung-Jung; Son, Hyun Hwa; Ryu, Cheol Woo; Chon, Kwon Su; Park, Seong Hoon; Juhng, Sun Kwan

    2012-12-01

    The feasibility of using monochromatic x-ray imaging generated from an x-ray tube and a multilayer reflector for digital mammography with a low radiation dose was examined. A multilayer mirror was designed to select the x-ray peak with an energy of 21.5 keV generated from an x-ray tube with a tungsten target and was fabricated by the ion-beam sputtering deposition system. Monochromatic x-ray images were obtained from an experimental digital mammography setup with a scanning stage. The performance of the system was evaluated using a breast phantom, a spectrometer, and a radiation dosimeter. We measured the contrast-to-noise ratio and performed the 10% modulation function test to determine image quality and resolution. The monochromatic beam from the multilayer reflector had a full-width-at-half-maximum of 0.9 keV at 21.5 keV, and the reflectivity was 0.70, which was 90% of the designed value. The polychromatic and monochromatic x-rays showed radiation doses of 0.497 and 0.0415 mGy, respectively. The monochromatic x-ray image shows fibers, calcifications, and masses more clearly than the polychromatic x-ray images do. The image contrast of the monochromatic x-rays was 1.85 times higher than that of the polychromatic x-rays. The experimental mammography setup had a spatial resolution of 7 lp/mm with both x-rays. Monochromatic x-rays generated using a multilayer mirror may be a useful diagnostic tool for breast examination by providing high contrast imaging with a low radiation dose.

  13. Development and characterization of real-time wide-energy range personal neutron dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takashi; Tsujimura, Norio (Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center); Yamano, Toshiya; Suzuki, Toshikazu; Okamoto, Eisuke

    1994-04-01

    The authors developed a real-time personal neutron dosimeter which could give neutron dose equivalent over wide energy region from thermal to 10 odd MeV by using 2 silicon detectors, fast neutron sensor and slow neutron sensor. The energy response of this dosimeter was evaluated under thermal neutron field, monoenergetic neutron field between 200 keV and 15 MeV, and moderated [sup 252]Cf neutron field. The neutron dose equivalent was estimated by adding neutron dose equivalent below 1 MeV given by slow neutron sensor and that above 1 MeV by fast neutron sensor. It was verified from various field tests that this dosimeter is able to give neutron dose equivalent within a factor of 2 margin of accuracy in reactor, accelerator, fusion research and nuclear fuel handling facilities. This dosimeter has more than one order higher sensitivity than conventional personal neutron dosimeters and is insensitive to [gamma]-rays up to about 500 mSv/h. This dosimeter will soon be commercially available as a personal dosimeter which gives neutron and [gamma]-ray dose equivalents simultaneously by installing [gamma]-ray silicon sensor. (author).

  14. Estimated neutron dose to embryo and foetus during commercial flight

    International Nuclear Information System (INIS)

    Chen, J.; Lewis, B. J.; Bennett, L. G. I.; Green, A. R.; Tracy, B. L.

    2005-01-01

    A study has been carried out to assess the radiation exposure from cosmic-ray neutrons to the embryo and foetus of pregnant aircrew and air travellers in consideration of the radiation exposure from cosmic-ray neutrons to the embryo and foetus. A Monte Carlo analysis was performed to determine the equivalent dose from neutrons to the brain and body of an embryo at 8 weeks and to the foetus at the 3, 6 and 9 month periods. Neutron fluence-to-absorbed dose conversion coefficients for the foetal brain and for the entire foetal body (isotropic irradiation geometry) have been determined at the four developmental stages. The equivalent dose rate to the foetus during commercial flights has been further evaluated considering the fluence-to-absorbed dose conversion coefficients, a neutron spectrum measured at an altitude of 11.3 km and an ICRP-92 radiation-weighting factor for neutrons. This study indicates that the foetus can exceed the annual dose limit of 1 mSv for the general public after, for example, 15 round trips on commercial trans-Atlantic flights. (authors)

  15. Dose field research of analysis room for in-hospital neutron irradiator

    International Nuclear Information System (INIS)

    Zhang Zizhu; Song Mingzhe; Li Wei; Chen Jun; Yang Yong; Li Yiguo

    2012-01-01

    Neutron equivalent dose rate and y ray dose rate inside the analysis room of the in-hospital neutron irradiator (IHNI) and outdoor were measured. The results show that γ ray dose rate inside the analysis room exceeds calculation value many times and γ/ ray dose rate outdoor is higher than supervision region dose limit of 7.5 μSv/h. According to the measurement results and the Monte Carlo simulation, the following shielding plan was adopted. Lead shielding with thickness of 16 cm was installed on the wall, which faces the neutron beam, to shield γ ray, and lithium polyethylene plate with thickness of l cm was installed on all the wall (not including ceiling and floor) to shield scattering neutron. After shielding transformation, the highest γ ray dose rate point inside the analysis room decreased 277 times, the neutron equivalent dose rate decreased 5.8 times, and the outdoor γ/ray dose rate decreased nearly 90 times. (authors)

  16. A neutron irradiator applied to cancer treatment

    International Nuclear Information System (INIS)

    Campos, Tarcisio P.R.; Andrade, Ana P. de

    2000-01-01

    Cancer and the way of treating it with neutron capture therapy are addressed. This paper discusses also the type of neutron facilities used to treat cancer around the world, as follow: discrete neutron sources, accelerators, and nuclear reactors. The major features of an epithermal neutron irradiation facility applied to BNCT treatment are addressed. The main goal is to give another choice of neutron irradiators to be set in a hospital. The irradiation facility embeds a set of 252 Cf neutron source coupled with a homogeneous mixture of uranium-zirconium hydride alloy containing 8.4 wt % uranium enriched to 20% U 235 . The facility delivers an epithermal neutron beam with low background of fast neutron and gamma rays. The N particle transport code (MCNP-4A) has been used during the simulation in order to achieve the desired configurations and to estimate the multiplication factor, k eff . The present facility loaded with 30 mg of 252 Cf neutron source generates an external beam with an intensity of 10 7 n/cm 2 .s on the spectrum of 4 eV to 40 KeV. The 252 Cf - facility coupled with fissile material was able to amplify the epithermal flux to 10 8 n/cm 2 .s, maintaining the figure-of-merits represented by the ratios of the fast dose and gamma dose in air per epithermal neutron flux closed to those values presented by BMRR, MITR-II and Petten Reactor. The medical irradiation facility loaded with 252 Cf- 235 U can be a choice for BNCT. (author)

  17. Focused Study of Thermonuclear Bursts on Neutron Stars

    Science.gov (United States)

    Chenevez, Jérôme

    2009-05-01

    X-ray bursters form a class of Low Mass X-Ray Binaries where accreted material from a donor star undergoes rapid thermonuclear burning in the surface layers of a neutron star. The flux released can temporarily exceed the Eddington limit and drive the photosphere to large radii. Such photospheric radius expansion bursts likely eject nuclear burning ashes into the interstellar medium, and may make possible the detection of photoionization edges. Indeed, theoretical models predict that absorption edges from 58Fe at 9.2 keV, 60Zn and 62Zn at 12.2 keV should be detectable by the future missions Simbol-X and NuSTAR. A positive detection would thus probe the nuclear burning as well as the gravitational redshift from the neutron star. Moreover, likely observations of atomic X-ray spectral components reflected from the inner accretion disk have been reported. The high spectral resolution capabilities of the focusing X-ray telescopes may therefore make possible to differentiate between the potential interpretations of the X-ray bursts spectral features.

  18. Neutron measurements as fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Hoek, M.

    1993-01-01

    Neutron measurements play important roles as the diagnostics of many aspects of the plasma in large tokamak devices such as JT-60U and JET. In the d-d discharges of JT-60U, the most important application of the neutron measurement is the investigation of the fusion performance using fission chambers. The ion velocity distribution function, and the triton slowing down are investigated by the neutron spectrometer and the 14 MeV neutron detector, respectively. TANSY is a combined proton-recoil and neutron time-of flight spectrometer for 14 MeV neutrons to be used during the d-t phase at JET. The detection principle is based on the measurements of the flight time of a scattered initial neutron and the energy of a corresponding recoil proton. The scattering medium is a polyethylene foil. The resolution and efficiency, using a thin foil (0.95 mg/cm 2 ), is 155 keV and 1.4x10 -5 cm 2 , respectively. (author)

  19. Characteristics of ZnO Wafers Implanted with 60 keV Sn+ Ions at Room Temperature and at 110 K

    International Nuclear Information System (INIS)

    Dang, Giang T.; Taniwaki, Masafumi; Kawaharamura, Toshiyuki; Hirao, Takashi; Nitta, Noriko

    2011-01-01

    ZnO wafers implanted with 60 keV Sn + ions at room temperature (RT) and at 110 K are investigated by means of X-ray diffraction (XRD) and photoluminescence (PL) techniques. The effect of implantation temperature is evident in the XRD and PL data. A yellow-orange (YO) band near 600 nm appears in the PL spectra of the ZnO wafers implanted to the doses of 4x10 14 and 8x10 14 ions/cm 2 at RT. The intensity of this band increases and the peak position blue-shifts after illumination of the samples with the 325 nm line of a He-Cd laser. The PL data suggests that the CB (conduction band)→V O + and Zn i + →V Zn - transitions contribute to the photoemission of the YO band.

  20. Fast neutron radiation inactivation of Bacillus subtilis: Absorbed dose determination

    International Nuclear Information System (INIS)

    Song Lingli; Zheng Chun; Ai Zihui; Li Junjie; Dai Shaofeng

    2011-01-01

    In this paper, fast neutron inactivation effects of Bacillus subtilis were investigated with fission fast neutrons from CFBR-II reactor of INPC (Institute of Nuclear Physics and Chemistry) and mono-energetic neutrons from the Van de Graaff accelerator at Peking University. The method for determining the absorbed dose in the Bacillus subtilis suspension contained in test tubes is introduced. The absorbed dose, on account of its dependence on the volume and the form of confined state, was determined by combined experiments and Monte Carlo method. Using the calculation results of absorbed dose, the fast neutron inactivation effects on Bacillus subtilis were studied. The survival rates and absorbed dose curve was constructed. (authors)

  1. A neutron detector for measurement of total neutron production cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Kern, B.D.; Gabbard, F.

    1976-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p, n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p, n) 51 Cr and 57 Fe(p, n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given. (Auth.)

  2. The Los Alamos Neutron Science Center Spallation Neutron Sources

    International Nuclear Information System (INIS)

    Nowicki, Suzanne F.; Wender, Stephen A.; Mocko, Michael

    2017-01-01

    The Los Alamos Neutron Science Center (LANSCE) provides the scientific community with intense sources of neutrons, which can be used to perform experiments supporting civilian and national security research. These measurements include nuclear physics experiments for the defense program, basic science, and the radiation effect programs. This paper focuses on the radiation effects program, which involves mostly accelerated testing of semiconductor parts. When cosmic rays strike the earth's atmosphere, they cause nuclear reactions with elements in the air and produce a wide range of energetic particles. Because neutrons are uncharged, they can reach aircraft altitudes and sea level. These neutrons are thought to be the most important threat to semiconductor devices and integrated circuits. The best way to determine the failure rate due to these neutrons is to measure the failure rate in a neutron source that has the same spectrum as those produced by cosmic rays. Los Alamos has a high-energy and a low-energy neutron source for semiconductor testing. Both are driven by the 800-MeV proton beam from the LANSCE accelerator. The high-energy neutron source at the Weapons Neutron Research (WNR) facility uses a bare target that is designed to produce fast neutrons with energies from 100 keV to almost 800 MeV. The measured neutron energy distribution from WNR is very similar to that of the cosmic-ray-induced neutrons in the atmosphere. However, the flux provided at the WNR facility is typically 5×107 times more intense than the flux of the cosmic-ray-induced neutrons. This intense neutron flux allows testing at greatly accelerated rates. An irradiation test of less than an hour is equivalent to many years of neutron exposure due to cosmic-ray neutrons. The low-energy neutron source is located at the Lujan Neutron Scattering Center. It is based on a moderated source that provides useful neutrons from subthermal energies to ~100 keV. The characteristics of these sources

  3. The Los Alamos Neutron Science Center Spallation Neutron Sources

    Science.gov (United States)

    Nowicki, Suzanne F.; Wender, Stephen A.; Mocko, Michael

    The Los Alamos Neutron Science Center (LANSCE) provides the scientific community with intense sources of neutrons, which can be used to perform experiments supporting civilian and national security research. These measurements include nuclear physics experiments for the defense program, basic science, and the radiation effect programs. This paper focuses on the radiation effects program, which involves mostly accelerated testing of semiconductor parts. When cosmic rays strike the earth's atmosphere, they cause nuclear reactions with elements in the air and produce a wide range of energetic particles. Because neutrons are uncharged, they can reach aircraft altitudes and sea level. These neutrons are thought to be the most important threat to semiconductor devices and integrated circuits. The best way to determine the failure rate due to these neutrons is to measure the failure rate in a neutron source that has the same spectrum as those produced by cosmic rays. Los Alamos has a high-energy and a low-energy neutron source for semiconductor testing. Both are driven by the 800-MeV proton beam from the LANSCE accelerator. The high-energy neutron source at the Weapons Neutron Research (WNR) facility uses a bare target that is designed to produce fast neutrons with energies from 100 keV to almost 800 MeV. The measured neutron energy distribution from WNR is very similar to that of the cosmic-ray-induced neutrons in the atmosphere. However, the flux provided at the WNR facility is typically 5×107 times more intense than the flux of the cosmic-ray-induced neutrons. This intense neutron flux allows testing at greatly accelerated rates. An irradiation test of less than an hour is equivalent to many years of neutron exposure due to cosmic-ray neutrons. The low-energy neutron source is located at the Lujan Neutron Scattering Center. It is based on a moderated source that provides useful neutrons from subthermal energies to ∼100 keV. The characteristics of these sources, and

  4. Dose response of thin-film dosimeters irradiated with 80-120 keV electrons

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.; Sharpe, P.

    2005-01-01

    Thin-film dosimeters (Riso B3 and alanine films) were irradiated at 10 MeV and 80-120 keV electron accelerators, and it has been shown that the radiation response of the dosimeter materials (the radiation chemical yields) are constant at these irradiation energies. However, dose gradients within ...... are present within the dosimeter. (C) 2005 Elsevier Ltd. All rights reserved....

  5. Accretion Properties of a Sample of Hard X-Ray (<60 keV) Selected Seyfert 1 Galaxies

    Science.gov (United States)

    Wang, J.; Mao, Y. F.; Wei, J. Y.

    2009-02-01

    We examine the accretion properties in a sample of 42 hard (3-60 keV) X-ray selected nearby broad-line active galactic nuclei (AGNs). The energy range in the sample is harder than that usually used in similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey, and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad Hβ emission line. The tight correlation between the hard X-ray (3-20 keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the Hβ emission line. In addition, all of these hard X-ray AGNs are biased toward luminous objects with a high Eddington ratio (mostly between 0.01 and 0.1) and a low column density (Simbol-X, and NeXT. Finally, the correlation between RFe (= optical Fe II/Hβ) and disk temperature as assessed by T vprop (L/L Edd)M -1 BH leads us to suggest that the strength of the Fe II emission is mainly determined by the shape of the ionizing spectrum.

  6. Preliminary characterization of the passive neutron dose equivalent monitor with TLDs

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Kanai, Katsuta; Momose, Takumaro; Hayashi, Naomi [Japan Nuclear Cycle Development Inst., Tokai Works, Tokai, Ibaraki (Japan); Chen Erhu [Beijing Institute of Nuclear Engineering, Beijing (China)

    2001-02-01

    The passive neutron dose equivalent monitor with TLDs is composed of a cubic polyethylene moderator and TLDs at the center of moderator. This monitor was originally designed for measurements of neutron doses over long-term period of time around the nuclear facilities. In this study, the energy response of this monitor was calculated by Monte Carlo methods and experimentally obtained under {sup 241}Am-Be, {sup 252}Cf and moderated {sup 252}Cf neutron irradiation. Additionally, the responses of two types of conventional neutron dose equivalent meters (rem counters) were also investigated as comparison. The authors concluded that this passive neutron monitor with TLDs had a good energy response similar to conventional rem counters and could evaluate neutron doses within 10% of accuracy to the moderated fission spectra. (author)

  7. Elemental analysis of fertilizer by fast neutron activation

    International Nuclear Information System (INIS)

    Bodart, F.; Deconninck, G.

    1977-01-01

    A simple and accurate technique has been developed to analyse commercial fertilizers for phosphorus, potassium, chlorine, magnesium and silicon. The method is based on fast-neutron activation using a neutron flux of 2x10 11 neutrons/second. The optimum analytical conditions are tabulated. After irradiation, the sample is measured on a conventional counting system including a Ge(Li) detector (10% efficiency and 2 keV resolution for 60 Co) and a multichannel analyser. Monitor foils radioactivity are measured separately at the same time with a 2''x2''NaI detector coupled with a single channel analyser and a scaler. Fast neutron activation has proved to be a fast, simple, reliable and low cost analytical technique for the determination of phosphorus, silicon, potassium, magnesium and chlorine in fertilizers. Not less than five phosphorus determinations are possible in one hour, while two potassium, magnesium and chlorine determinations are made at the same time. (T.G.)

  8. Creation and testing of an ENDF/B-VI neutron data library (ENDF60) for use with MCNP trademark

    International Nuclear Information System (INIS)

    Frankle, S.C.; MacFarlane, R.E.

    1995-01-01

    The continuous-energy neutron data library ENDF60, for use with the Monte Carlo N Particle radiation transport code MCNP4A, was released in the fall of 1994. The ENDF60 library is comprised of 124 nuclide data files based on the ENDF/B-VI evaluations through Release 2. Fifty-two percent of these ENDF/B-VI evaluations are translations from ENDF/B-V. The remaining forty-eight percent are new evaluations which have sometimes changed significantly. The new evaluations include important materials for criticality safety calculations, as well as significant enhancements such as isotopic evaluations, better resonance-range representations, and the new correlated energy-angle distributions for emitted particles. In particular, the upper energy limit for the resolved resonance region of 235 U, 238 U and 239 Pu has been extended from 0.082, 4.0, and 0.301 keV to 2.25, 10.0, and 2.5 keV respectively. As part of the overall quality assurance testing of the ENDF60 library, calculations for well known benchmark assemblies were performed. This benchmarking effort included revising the standard nine criticality benchmarks documented in previous Los Alamos National Laboratory Reports, LA-12212 and LA-12891, as well as the implementation of new Cross Section Evaluation Working Group (CSEWG) benchmarks. Comparisons of benchmark results for different data libraries can aid the user in understanding how well an evaluation performs for their application

  9. The equidosemeter ED-02 as a device for dose equivalent measurements in mixed neutron and photon radiation fields

    International Nuclear Information System (INIS)

    Abrosimov, A.I.; Alekseev, A.G.; Antipov, V.A.; Golovachik, V.T.

    1985-01-01

    The equidosemeter ED-02 is to be used for simultaneous measurements of the dose equivalent, absorbed dose, and mean quality factor of mixed radiations. The detector is a tissue equivalent spherical low-pressure proportional counter tube the signal of which is simultaneously recorded in two channels - a current channel and a pulse one. The current channel is linear and its response proportional to the absorbed dose. The pulse channel includes a nonlinear pulse amplitude converter the characteristic of which, taking into account the required dependence of the mean quality factor on linear energy transfer, has been chosen in such a way that in final counting the pulse channel response is proportional to the difference between dose equivalent and absorbed dose. On the basis of calculations of event spectra in the sensitive volume of the detector, the energy dependence of the dosemeter sensitivity is analysed for neutron energies up to 20 MeV. The characteristic of the nonlinear converter has been calculated on the basis of the construction parameters of the detector and optimized with respect to a representative sample of neutron spectra beyond the shields of nuclear plants. The heterogeneity of the detector, i.e. the difference between the atomic composition of wall and filling and the composition of soft biological tissue as well as the effect of the conducting coating of the case cathode, has been taken into consideration. Moreover, the test results of the device in mixed neutron-photon fields of 60 Co, 239 Pu-α-Be and 252 Cf radioisotope sources are presented. The main measuring error of dose characteristics is shown to be less than 20% in the dose range 1 x 10 -3 to 4 x 10 -3 Sv/h. (author)

  10. Accuracy of neutron dose evaluation in the area monitoring for LHD experiments

    CERN Document Server

    Yamanishi, H; Uda, T; Tanahashi, S; Saitou, M; Handa, H

    2000-01-01

    The error in the evaluation of neutron dose during calculation of the neutron field around the large helical device (LHD) in D-D operation is discussed. The expected neutron dose at each monitoring point was derived from the dose conversion factor and neutron fluence data, which was calculated with the radiation transport code DOT-3.5. In contrast, the detected dose at the neutron counter was obtained from the fluence data and the detector response given by calculation with MCNP-4b. The neutron counter used in these calculations consisted of a helium-3 proportional counter with a cylindrical polyethylene moderator. According to the results of the calculations, the ratio of the detected dose to the expected dose was found to lie in the range 1.0-3.0 on the outdoor monitoring points. Since the response of a single neutron counter may lead to inconsistencies in the dose conversion factor, we attempted to minimize these inconsistencies by using a pair of counters with moderators of different thickness. The ratio ...

  11. Evaluation of response function of moderating-type neutron detector and application to environmental neutron measurement

    International Nuclear Information System (INIS)

    Kosako, Toshiso; Nakamura, Takashi; Iwai, Satoshi; Katsuki, Shinji; Kamata, Masashi.

    1983-08-01

    The energy-dependent response function of a multi-cylinder moderating-type BF 3 counter, so-called Bonner counter, was calculated by the time-dependent multi-group Monte Carlo code, TMMCR. The calculated response function was evaluated experimentally for neutron energy below about 50 keV down to epithermal energy by the time-of-flight method combining with a large lead pile at the Nuclear Engineering Research Laboratory, University of Tokyo and also above 50 keV by using the monoenergetic neutron standard field a t the Electrotechnical Laboratory. The time delay in the polyethylene moderator of the Bonner counter due to multiple collisions with hydrogen was analyzed by the TMMCR code and used for the time-spectrum analysis of the time-of-flight measurement. The response function obtained by these two experiments showed good agreement with the calculated results. This Bonner counter having a response function evaluated from thermal to MeV energy range was used for spectrometry and dosimetry of environmental neutrons around some nuclear facilities. The neutron spectra and dose measured in the environment around a 252 Cf fission source, fast neutron source reactor and electron synchrotron were all in good agreement with the calculated results and the measured results with other neutron detectors. (author)

  12. Measurement and assessment of mixed neutron-gamma radiation fields around the reconstructed HWRR

    International Nuclear Information System (INIS)

    Chen Changmao; Xie Jianlun; Chun Yuqing; Lin Nairong; Liu Jinhua; Su Jingling; Wei Zemin

    1987-01-01

    The neutron spectra around the HWRR (Heavy Water Research Reactor) of the Institute of Atomic Energy of China were measured. For the neutron spectra at different measuring points, the mean neutron energies ranged from 11 to 201 keV, the maximum energies were below 5 MeV, the effective quality factors were between 2.5 and 5, and the fast neutron dose equivalents mostly contributed the large fraction. During normal operation of the reactor, the n-γ dose equivalent rates in working areas were measured as well. In the experimental hall and the basement of the reactor, the mean values of the n/γ dose equivalent ratios were 15% and 31%, respectively; the γ dose equivalents were predominant. The annual dose equivalents to the persons working in the areas mentioned above possibly exceed the dose equivalent limit

  13. Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.N. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Division of Health Physics, Institute of Nuclear Energy Research, No. 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Huang, C.K. [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Tsai, W.C. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, Y.H. [Nuclear Science and Technol. Develop. Center, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Jiang, S.H., E-mail: shjiang@mx.nthu.edu.tw [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-12-15

    This paper aims to evaluate the effective dose as well as equivalent doses of several organs of an adult hermaphrodite mathematical phantom according to the definition of ICRP Publication 60 for BNCT treatments of brain tumors in the epithermal neutron beam at THOR. The MCNP5 Monte Carlo code was used for the calculation of the average absorbed dose of each organ. The effective doses for a typical brain tumor treatment with a tumor treatment dose of 20 Gy-eq were evaluated to be 0.59 and 0.35 Sv for the LLAT and TOP irradiation geometries, respectively. In addition to the stochastic effect, it was found that it is also likely to produce deterministic effects, such as cataracts and depression of haematopoiesis.

  14. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Starkenburg, Daken J. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Johns, Paul M. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Detection Systems Group, Pacific Northwest National Laboratory, Richland, Washington 99354, USA; Baciak, James E. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Nino, Juan C. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Xue, Jiangeng [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA

    2017-12-14

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  15. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Science.gov (United States)

    Starkenburg, Daken J.; Johns, Paul M.; Baciak, James E.; Nino, Juan C.; Xue, Jiangeng

    2017-12-01

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.18 μGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  16. Intercomparison of personnel dosimetry for thermal neutron dose equivalent in neutron and gamma-ray mixed fields

    International Nuclear Information System (INIS)

    Ogawa, Yoshihiro

    1985-01-01

    In order to consider the problems concerned with personnel dosimetry using film badges and TLDs, an intercomparison of personnel dosimetry, especially dose equivalent responses of personnel dosimeters to thermal neutron, was carried out in five different neutron and gamma-ray mixed fields at KUR and UTR-KINKI from the practical point of view. For the estimation of thermal neutron dose equivalent, it may be concluded that each personnel dosimeter has good performances in the precision, that is, the standard deviations in the measured values by individual dosimeter were within 24 %, and the dose equivalent responses to thermal neutron were almost independent on cadmium ratio and gamma-ray contamination. However, the relative thermal neutron dose equivalent of individual dosimeter normalized to the ICRP recommended value varied considerably and a difference of about 4 times was observed among the dosimeters. From the results obtained, it is suggested that the standardization of calibration factors and procedures is required from the practical point of radiation protection and safety. (author)

  17. Phantom experiment of depth-dose distributions for gadolinium neutron capture therapy

    International Nuclear Information System (INIS)

    Matsumoto, T.; Kato, K.; Sakuma, Y.; Tsuruno, A.; Matsubayashi, M.

    1993-01-01

    Depth-dose distributions in a tumor simulated phantom were measured for thermal neutron flux, capture gamma-ray and internal conversion electron dose rates for gadolinium neutron capture therapy. The results show that (i) a significant dose enhancement can be achieved in the tumor by capture gamma-rays and internal conversion electrons but the dose is mainly due to capture gamma-rays from the Gd(n, γ) reactions, therefore, is not selective at the cellular level, (ii) the dose distribution was a function of strongly interrelated parameters such as gadolinium concentrations, tumor site and neutron beam size (collimator aperture size), and (iii) the Gd-NCT by thermal neutrons appears to be a potential for treatment of superficial tumor. (author)

  18. Critical study of some soft-tissue equivalent material. Sensitivity to neutrons of 1 keV to 14 MeV

    International Nuclear Information System (INIS)

    Kerviler, H. de; Pages, L.; Tardy-Joubert, Ph.

    1965-01-01

    Authors have studied the elastic and inelastic reactions on various elements contribution to kerma in standard soft tissue and as a function of neutron energy from 1 keV to 14 MeV the ratio of kerma in tissue equivalent material to kerma in soft tissue. The results of calculations are made for materials without hydrogen in view to state exactly their neutron sensitivity and for the following hydrogenous materials: Rossi and Failla plastic, MixD, pure polyethylene and a new CEA tissue equivalent (a magnesium fluoride and polyethylene compound). Results for γ-rays are given. (authors) [fr

  19. Decommissioning of a 60Co unit and estimation of personal doses

    International Nuclear Information System (INIS)

    Lin, H.; Lin, P.; Liu, T.; Chu, C.

    2003-01-01

    Chang-hua Christian hospital needs to uninstall the 60 Co unit. The mode of this 60 Co teletherapy unit is SHIMADZU RTGS-10. The original lead head was taken as the source container of this 60 Co unit. The source head was dismantled and put into the prepared wooden box, after the source was sealed. This study describes the planning and dismantling of the retirement and transport of the 60 Co unit, and personal doses measured during the procedure. This work estimates the doses of radiation received by exposed workers during the dismantling of the machine. The workers received doses of approximately 53 μSv. This study shows that the original lead head can be used as the source container of this 60 Co unit. The 60 Co machine was smoothly dismantled and transported by conscientious and careful workers, using planned and controlled radiation protection, following the ALARA (as low as reasonably achievable) rule. (author)

  20. The total neutron cross section of 58Fe in the energy range 7 to 325 keV

    International Nuclear Information System (INIS)

    Hong, L.D.; Beer, H.; Kaeppeler, F.

    1976-08-01

    The total neutron cross section of 58 Fe has been determined in the energy range 7-325 keV by a transmission measurement using enriched 58 Fe samples. The data have been shape fitted by means of an R-matrix multi-level formalism to extract resonance parameters for s- and l > 0 wave resonances. The s-wave strength function was determined to S 0 = (4.3 +- 1.9) c 10 -4 . (orig.) [de

  1. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds; Efeitos de baixas doses de radiacao gama do Co-60 (radio-hormesis) em sementes de tomate

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni Andreas

    2010-07-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5{sup th} leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  2. Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Howell, Rebecca M., E-mail: rhowell@mdanderson.org [Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States); Burgett, Eric A.; Isaacs, Daniel [Department of Nuclear Engineering, Idaho State University, Pocatello, Idaho (United States); Price Hedrick, Samantha G.; Reilly, Michael P.; Rankine, Leith J.; Grantham, Kevin K.; Perkins, Stephanie; Klein, Eric E. [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States)

    2016-05-01

    Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

  3. Benchmark of PENELOPE code for low-energy photon transport: dose comparisons with MCNP4 and EGS4

    International Nuclear Information System (INIS)

    Ye, Sung-Joon; Brezovich, Ivan A; Pareek, Prem; Naqvi, Shahid A

    2004-01-01

    The expanding clinical use of low-energy photon emitting 125 I and 103 Pd seeds in recent years has led to renewed interest in their dosimetric properties. Numerous papers pointed out that higher accuracy could be obtained in Monte Carlo simulations by utilizing newer libraries for the low-energy photon cross-sections, such as XCOM and EPDL97. The recently developed PENELOPE 2001 Monte Carlo code is user friendly and incorporates photon cross-section data from the EPDL97. The code has been verified for clinical dosimetry of high-energy electron and photon beams, but has not yet been tested at low energies. In the present work, we have benchmarked the PENELOPE code for 10-150 keV photons. We computed radial dose distributions from 0 to 10 cm in water at photon energies of 10-150 keV using both PENELOPE and MCNP4C with either DLC-146 or DLC-200 cross-section libraries, assuming a point source located at the centre of a 30 cm diameter and 20 cm length cylinder. Throughout the energy range of simulated photons (except for 10 keV), PENELOPE agreed within statistical uncertainties (at worst ±5%) with MCNP/DLC-146 in the entire region of 1-10 cm and with published EGS4 data up to 5 cm. The dose at 1 cm (or dose rate constant) of PENELOPE agreed with MCNP/DLC-146 and EGS4 data within approximately ±2% in the range of 20-150 keV, while MCNP/DLC-200 produced values up to 9% lower in the range of 20-100 keV than PENELOPE or the other codes. However, the differences among the four datasets became negligible above 100 keV

  4. Benchmark of PENELOPE code for low-energy photon transport: dose comparisons with MCNP4 and EGS4.

    Science.gov (United States)

    Ye, Sung-Joon; Brezovich, Ivan A; Pareek, Prem; Naqvi, Shahid A

    2004-02-07

    The expanding clinical use of low-energy photon emitting 125I and 103Pd seeds in recent years has led to renewed interest in their dosimetric properties. Numerous papers pointed out that higher accuracy could be obtained in Monte Carlo simulations by utilizing newer libraries for the low-energy photon cross-sections, such as XCOM and EPDL97. The recently developed PENELOPE 2001 Monte Carlo code is user friendly and incorporates photon cross-section data from the EPDL97. The code has been verified for clinical dosimetry of high-energy electron and photon beams, but has not yet been tested at low energies. In the present work, we have benchmarked the PENELOPE code for 10-150 keV photons. We computed radial dose distributions from 0 to 10 cm in water at photon energies of 10-150 keV using both PENELOPE and MCNP4C with either DLC-146 or DLC-200 cross-section libraries, assuming a point source located at the centre of a 30 cm diameter and 20 cm length cylinder. Throughout the energy range of simulated photons (except for 10 keV), PENELOPE agreed within statistical uncertainties (at worst +/- 5%) with MCNP/DLC-146 in the entire region of 1-10 cm and with published EGS4 data up to 5 cm. The dose at 1 cm (or dose rate constant) of PENELOPE agreed with MCNP/DLC-146 and EGS4 data within approximately +/- 2% in the range of 20-150 keV, while MCNP/DLC-200 produced values up to 9% lower in the range of 20-100 keV than PENELOPE or the other codes. However, the differences among the four datasets became negligible above 100 keV.

  5. A Selective Neutron Detector in the keV Region Utilizing the {sup 19}F (n, gamma) {sup 20}F Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Konijn, J

    1963-05-15

    The Research Swimming-Pool Reactor R2-0 at Studsvik has been used to investigate some resonance and threshold reactions for neutron flux measurements. This reactor, equipped with MTR type fuel elements, has a maximum neutron flux of about 10{sup 12} n/cm{sup 2}/sec, giving a thermal output of 100 kW. A pneumatic rabbit was constructed to bring the samples in activation position, in which there was 15 cm H{sub 2}O and 1.2 cm Al between reactor and foil. A covering, containing 1.22 g {sup 10}B/cm{sup 2} was pushed over the cadmium-covered Al tube of the rabbit. The activation of the foil was measured with a Nal(Tl)-scintillation spectrometer. From the gamma ray spectrum, recorded on a 256 channel pulse height analyzer, the epithermal neutron flux per unit of In E interval was calculated. The activation cross section for {sup 19}F (n, {gamma}) {sup 20}F in the {sup 10}B-covering was computed to be 16 mb, and about 60 % of the induced activity is due to neutrons in the energy range of 20-70 keV. The experimental results were compared with those obtained from the more known resonance reactions {sup 63}Cu (n, {gamma}) {sup 64}Cu and {sup 27}Al (n, {gamma}) {sup 28}Al. The epithermal neutron flux experiments are in good agreement with each other. The fast neutron flux measurements were carried out with the following threshold detectors: {sup 197}Au (n, n') {sup 197m}Au, {sup 58}Ni (n, p) {sup 58}Co, {sup 27}Al (n, p) {sup 27}Mg and {sup 19}F (n, p) {sup 19}O. From these experiments the ratio of {phi}{sub epi}/{phi}{sub fiss} =0.045 {+-} 0.010 is determined at the activation position. The half-life of {sup 197}Au m was determined to 7.35 {+-} 0.25 sec.

  6. Neutron capture cross section measurements of 109Ag, 186W and 158Gd on filtered neutron beams of 55 and 144 keV

    International Nuclear Information System (INIS)

    Vuong Huu Tan; Nguyen Canh Hai; Pham Ngoc Son; Tran Tuan Anh

    2004-12-01

    The neutron capture cross sections of the 109 Ag(n, γ) 110 mAg, 186 W(n, γ) 187 W and 158 Gd(n, γ) 159 Gd have been measured at 55 and 144 keV by the activation method with filtered neutron beams of the Dalat nuclear research reactor. The cross sections were determined relative to the standard capture cross sections of 197 Au using highly purity metallic foils of Ag, W, Gd and Au. The high efficient HPGe detector was used for the gamma rays measurement from the samples, and absolute efficiency calibration was performed by using a set of standard radioisotope sources and a multi-nuclides standard solution. The present results were compared with the previous measurements listed in EXFOR-CINDA, and the evaluated data of ENDF/B-VI. (author)

  7. Response of CR-39 based personnel neutron dosemeter in terms of directional dose equivalent, in free air and on phantom

    International Nuclear Information System (INIS)

    Pal, Rupali R.; Sathian, Deepa; Jayalakshmi, V.; Chougaonkar, M.P.

    2011-01-01

    CR-39 is the most sensitive of nuclear track detectors for protons and is recommended as an effective neutron dosimeter because of it's low threshold energy of 100 keV neutrons. The fraction of protons that gives detectable tracks in CR-39 depends on the energy of the proton angle of incidence and etching conditions. As a consequence the registration efficiency of neutrons in the CR-39 plastics used for neutron personnel monitoring is strongly influenced by the direction of radiation incidence. This paper presents the relative response of CR-39 at varying neutron incident angles, for 241 Am-Be neutron source spectra in free air and on ISO phantom, in terms of operational quantities. It is observed that the angular dependence of CR-39 for irradiations in air and on phantom is essentially the same indicating that the phantom does not affect the directional response of CR-39. (author)

  8. Evaluation of the neutron induced reactions on 235U from 2.25 keV up to 30 MeV

    Science.gov (United States)

    Trkov, Andrej; Capote, Roberto; Pigni, Marco T.; Pronyaev, Vladimir G.; Sin, Mihaela; Soukhovitskii, Efrem S.

    2017-09-01

    An evaluation of fast neutron induced reactions on 235U is performed in the 2.25 keV-30 MeV incident energy range with the code EMPIRE-3.2 Malta, combined with selected experimental data. The reaction model includes a dispersive optical model potential (RIPL 2408) that couples seven levels of the ground-state rotational band and a triple-humped fission barrier with absorption in the wells described within the optical model for fission. EGSM nuclear level densities are used in Hauser-Feshbach calculations of the compound-nuclear decay. The starting values for the model parameters are retrieved from the RIPL-3 data-base. Excellent agreement is achieved with available experimental data for neutron emission, neutron capture and fission, which gives confidence that the quantities for which there is no experimental information are also predicted accurately. In the fast neutron region of the evaluated file, the fission cross section is taken from Neutron Standards, and neutron capture includes fluctuations observed in recent experiments. Other channels are taken directly from model calculations. New evaluation is validated against ICSBEP criticality benchmarks with fast neutron spectra with excellent results.

  9. Construction of voxel head phantom and application to BNCT dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Sik; Lee, Choon Ik; Lee, Jai Ki [Hanyang Univ., Seoul (Korea, Republic of)

    2001-06-15

    Voxel head phantom for overcoming the limitation of mathematical phantom in depicting anatomical details was constructed and example dose calculation for BNCT was performed. The repeated structure algorithm of the general purpose Monte Carlo code, MCNP4B was applied for voxel Monte Carlo calculation. Simple binary voxel phantom and combinatorial geometry phantom composed of two materials were constructed for validating the voxel Monte Carlo calculation system. The tomographic images of VHP man provided by NLM(National Library of Medicine) were segmented and indexed to construct voxel head phantom. Comparison od doses for broad parallel gamma and neutron beams in AP and PA directions showed decrease of brain dose due to the attenuation of neutron in eye balls in case of voxel head phantom. The spherical tumor volume with diameter, 5cm was defined in the center of brain for BNCT dose calculation in which accurate 3 dimensional dose calculation is essential. As a result of BNCT dose calculation for downward neutron beam of 10keV and 40keV, the tumor dose is about doubled when boron concentration ratio between the tumor to the normal tissue is 30{mu}g/g to 3 {mu}g/g. This study established the voxel Monte Carlo calculation system and suggested the feasibility of precise dose calculation in therapeutic radiology.

  10. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

    Science.gov (United States)

    Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel

    2014-01-01

    High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by (241)Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy(-1) for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy(-1) achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production.

  11. Distributions of neutron yields and doses around a water phantom bombarded with 290-MeV/nucleon and 430-MeV/nucleon carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, D., E-mail: satoh.daiki@jaea.go.jp [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Kajimoto, T. [Hiroshima University, Kagamiyama, Higashi-Hiroshima-shi, Hiroshima 739-8527 (Japan); Shigyo, N.; Itashiki, Y.; Imabayashi, Y. [Kyushu University, Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Koba, Y.; Matsufuji, N. [National Institute of Radiological Sciences, Anagawa, Inage-ku, Chiba 263-8555 (Japan); Sanami, T. [High Energy Accelerator Research Organization, Oho-cho, Tsukuba-shi, Ibaraki 305-0801 (Japan); Nakao, N. [Shimizu Corporation, Etchujima, Koto-ku, Tokyo 135-8530 (Japan); Uozumi, Y. [Kyushu University, Motooka, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Double-differential neutron yields from a water phantom bombarded with 290-MeV/nucleon and 430-MeV/nucleon carbon ions were measured at emission angles of 15°, 30°, 45°, 60°, 75°, and 90°, and angular distributions of neutron yields and doses around the phantom were obtained. The experimental data were compared with results of the Monte-Carlo simulation code PHITS. The PHITS results showed good agreement with the measured data. On the basis of the PHITS simulation, we estimated the angular distributions of neutron yields and doses from 0° to 180° including thermal neutrons.

  12. Development of new instrumentation for epithermal neutron scattering at very low angles

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Gorini, G.; Perelli-Cippo, E.; Rhodes, N.J.; Schooneveld, E.M.; Senesi, R.

    2004-01-01

    New perspectives for epithermal neutron spectroscopy are opened up by the recent developments of Resonance Detectors (RD) for inverse geometry time-of-flight spectrometers at pulsed neutron sources. The RD is based on the combination of an analyser foil used as neutron-to-gamma converter and a suitable photon detector. Here, we report on the state of the RD which is based on a YAP scintillator viewing a natural uranium analyser foil. The response of the YAP detector to the radiative capture γ emission from the uranium analyser foil has been characterized with a bi-parametric measurement of a reference Pb sample, which allowed simultaneous measurements of both neutron time-of-flight and γ pulse height (energy) spectra. The analysis of the γ pulse height and neutron time-of-flight spectra permitted to identify the signal and background components. These measurements showed that a significant improvement in the signal-to-background ratio can be achieved by setting a lower level discrimination on the photon energy at about 600keV. The first application of RD is the Very Low Angle Detector Bank (VLAD) which is planned to be installed in the next three years as an upgrade of the VESUVIO spectrometer, at the ISIS pulsed neutron source. VLAD will extend the (q,ω) kinematical to low wave vector transfers (q10A-1) coupled to high-energy transfers (-bar ω>1eV), which is still unexplored by neutron scattering experiments. The first measurements obtained on an ice sample with a VLAD prototype consisting of four RD units are presented here

  13. Development of new instrumentation for epithermal neutron scattering at very low angles

    Energy Technology Data Exchange (ETDEWEB)

    Tardocchi, M. [INFM, UdR Milano-Bicocca and Dipartimento di Fisica ' G.Occhialini' , Universita degli Studi di Milano-Bicocca, Pizza Della Scienza 3, Milan 20126 (Italy)]. E-mail: marco.tardocchi@mib.infn.it; Pietropaolo, A. [Dipartimento di Fisica, Universita degli Studi di Roma Tor Vergata and INFM, UdR Roma Tor Vergata, Rome (Italy); Andreani, C. [Dipartimento di Fisica, Universita degli Studi di Roma Tor Vergata and INFM, UdR Roma Tor Vergata, Rome (Italy); Gorini, G. [INFM, UdR Milano-Bicocca and Dipartimento di Fisica ' G.Occhialini' , Universita degli Studi di Milano-Bicocca, Pizza Della Scienza 3, Milan 20126 (Italy); Perelli-Cippo, E. [INFM, UdR Milano-Bicocca and Dipartimento di Fisica ' G.Occhialini' , Universita degli Studi di Milano-Bicocca, Pizza Della Scienza 3, Milan 20126 (Italy); Rhodes, N.J. [Isis Facility, Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Schooneveld, E.M. [Isis Facility, Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Senesi, R. [Dipartimento di Fisica, Universita degli Studi di Roma Tor Vergata and INFM, UdR Roma Tor Vergata, Rome (Italy)

    2004-12-11

    New perspectives for epithermal neutron spectroscopy are opened up by the recent developments of Resonance Detectors (RD) for inverse geometry time-of-flight spectrometers at pulsed neutron sources. The RD is based on the combination of an analyser foil used as neutron-to-gamma converter and a suitable photon detector. Here, we report on the state of the RD which is based on a YAP scintillator viewing a natural uranium analyser foil. The response of the YAP detector to the radiative capture {gamma} emission from the uranium analyser foil has been characterized with a bi-parametric measurement of a reference Pb sample, which allowed simultaneous measurements of both neutron time-of-flight and {gamma} pulse height (energy) spectra. The analysis of the {gamma} pulse height and neutron time-of-flight spectra permitted to identify the signal and background components. These measurements showed that a significant improvement in the signal-to-background ratio can be achieved by setting a lower level discrimination on the photon energy at about 600keV. The first application of RD is the Very Low Angle Detector Bank (VLAD) which is planned to be installed in the next three years as an upgrade of the VESUVIO spectrometer, at the ISIS pulsed neutron source. VLAD will extend the (q,{omega}) kinematical to low wave vector transfers (q10A-1) coupled to high-energy transfers (-bar {omega}>1eV), which is still unexplored by neutron scattering experiments. The first measurements obtained on an ice sample with a VLAD prototype consisting of four RD units are presented here.

  14. Evaluation of two personal dosemeters in polyenergetic mono- and multi-directional neutron fields

    International Nuclear Information System (INIS)

    Nunes, J. C.; Surette, R. A.

    2005-01-01

    The neutron dose-equivalent response of two commercially available electronic personal neutron dosemeters was studied in several laboratory-produced broad-spectrum neutron fields. Fluence-weighted mean energies ranged from 200 keV to 4 MeV; personal dose-equivalent rates ranged from 75 to 10 mSv h -1 ; and angles of incidence were multidirectional, 0 deg., 30 deg. and 60 deg.. Three of these fields have been shown previously to resemble ones found in CANDU (Canadian Deuterium Uranium is a registered trademark of the Atomic Energy of Canada Limited) power plant workplaces. Both dosemeters were found to perform reasonably well across the range of energy spectra and angles of incidence. One type of dosemeter displayed values of the personal dose equivalent that were, at worst, within a factor of ∼2 of the reference values and, at best, within a few per cent of the reference values. The other type displayed values of the personal dose equivalent that were consistently within unity and 20% of the reference values. Although the radiological performance of one was found to be more accurate, this device was also found to be the less rugged of the two. Some of the data acquired in this work were compared with results previously published by others. There was consistency between these sets of data. (authors)

  15. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    production, Rayleigh scattering and bound Compton scattering were included in the simulation. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. The cut-off energy was 10 keV for electrons and photons. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. The liquid water density was 0.998 g/cm3, and photon histories of up to 1010 were used to obtain the results with a standard deviation of less than 0.5% (k = 1. The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range.

  16. Determination of neutron dose from criticality accidents with bioassays for sodium-24 in blood and phosphorus-32 in hair

    International Nuclear Information System (INIS)

    Feng, Y.; Miller, L.F.; Brown, K.S.; Casson, W.H.; Mei, G.T.; Thein, M.

    1993-06-01

    A comprehensive review of accident neutron dosimetry using blood and hair analysis was performed and is summarized in this report. Experiments and calculations were conducted at Oak Ridge National Laboratory (ORNL) and the University of Tennessee (UT) to develop measurement techniques for the activity of 24 Na in blood and 32 P in hair for nuclear accident dosimetry. An operating procedure was established for the measurement of 24 Na in blood using an HPGe detector system. The sensitivity of the measurement for a 20-mL sample is 0.01-0.02 Gy of total neutron dose for hard spectra and below 0.005 Gy for soft spectra based on a 30- to 60-min counting time. The operating procedures for direct counting of hair samples are established using a liquid scintillation detector. Approximately 0.06-0.1 Gy of total neutron dose can be measured from a 1-g hair sample using this procedure. Detailed procedures for chemical dissolution and ashing of hair samples are also developed. A method is proposed to use blood and hair analysis for assessing neutron dose based on a collection of 98 neutron spectra. Ninety-eight blood activity-to-dose conversion factors were calculated. The calculated results for an uncollided fission spectrum compare favorably with previously published data for fission neutrons. This nuclear accident dosimetry system makes it possible to estimate an individual's neutron dose within a few hours after an accident if the accident spectrum can be approximated from one of 98 tabulated neutron spectrum descriptions. If the information on accident and spectrum description is not available, the activity ratio of 32 P in hair and 24 Na in blood can provide information related to the neutron spectrum for dose assessment

  17. Measurements of 60Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999

    International Nuclear Information System (INIS)

    Gasparro, J.; Hult, M.; Komura, K.; Arnold, D.; Holmes, L.; Johnston, P.N.; Laubenstein, M.; Neumaier, S.; Reyss, J.-L.; Schillebeeckx, P.; Tagziria, H.; Van Britsom, G.; Vasselli, R.

    2004-01-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes γ-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring 60 Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from 60 Co activity is in agreement with previous measurements using the short-lived radionuclides 51 Cr and 59 Fe. Limits on contamination of the samples with 60 Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using 60 Co activation

  18. Measurements of 60Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999.

    Science.gov (United States)

    Gasparro, J; Hult, M; Komura, K; Arnold, D; Holmes, L; Johnston, P N; Laubenstein, M; Neumaier, S; Reyss, J-L; Schillebeeckx, P; Tagziria, H; Van Britsom, G; Vasselli, R

    2004-01-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes gamma-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring (60)Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from (60)Co activity is in agreement with previous measurements using the short-lived radionuclides (51)Cr and (59)Fe. Limits on contamination of the samples with (60)Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using (60)Co activation.

  19. Absolute calibration of the neutron yield measurement on JT-60 Upgrade

    International Nuclear Information System (INIS)

    Nishitani, Takeo; Takeuchi, Hiroshi; Barnes, C.W.

    1991-10-01

    Absolutely calibrated measurements of the neutron yield are important for the evaluation of the plasma performance such as the fusion gain Q in DD operating tokamaks. Total neutron yield is measured with 235 U and 238 U fission chambers and 3 He proportional counters in JT-60 Upgrade. The in situ calibration was performed by moving the 252 Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235 U and two 3 He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting absolute plasma neutron source calibration is estimated to be ± 10%. (author)

  20. Facility for gamma irradiations of cultured cells at low dose rates: design, physical characteristics and functioning

    International Nuclear Information System (INIS)

    Esposito, Giuseppe; Anello, Pasquale; Pecchia, Ilaria; Tabocchini, Maria Antonella; Campa, Alessandro

    2016-01-01

    We describe a low dose/dose rate gamma irradiation facility (called LIBIS) for in vitro biological systems, for the exposure, inside a CO_2 cell culture incubator, of cells at a dose rate ranging from few μGy/h to some tens of mGy/h. Three different "1"3"7Cs sources are used, depending on the desired dose rate. The sample is irradiated with a gamma ray beam with a dose rate uniformity of at least 92% and a percentage of primary 662 keV photons greater than 80%. LIBIS complies with high safety standards. - Highlights: • A gamma irradiation facility for chronic exposures of cells was set up at the Istituto Superiore di Sanità. • The dose rate uniformity and the percentage of primary 662 keV photons on the sample are greater than 92% and 80%, respectively. • The GEANT4 code was used to design the facility. • Good agreement between simulation and experimental dose rate measurements has been obtained. • The facility will allow to safely investigate different issues about low dose rate effects on cultured cells.

  1. A parameter study to determine the optimal source neutron energy in boron neutron capture therapy of brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Nievaart, V A [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands); Moss, R L [Joint Research Centre of the European Commission, Postbus 2, 1755ZG Petten (Netherlands); Kloosterman, J L [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands); Hagen, T H J J van der [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands); Dam, H van [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands)

    2004-09-21

    The values of the parameters used in boron neutron capture therapy (BNCT) to calculate a given dose to human tissue vary with patients due to different physical, biological and/or medical circumstances. Parameters include the tissue dimensions, the {sup 10}B concentration and the relative biological effectiveness (RBE) factors for the different dose components associated with BNCT. Because there is still no worldwide agreement on RBE values, more often than not, average values for these parameters are used. It turns out that the RBE-problem can be circumvented by taking into account all imaginable parameter values. Approaching this quest from another angle: the outcome will also provide the parameters (and values) which influence the optimal source neutron energy. For brain tumours it turns out that the {sup 10}B concentration, the RBE factors for {sup 10}B as well as fast neutrons, together with the dose limit set for healthy tissue, affect the optimal BNCT source neutron energy. By using source neutrons of a few keV together with neutrons of a few eV, it ensures that, under all imaginable circumstances, a maximum of alpha (and lithium) particles can be delivered in the tumour.

  2. Simulations of neutron transport at low energy: a comparison between GEANT and MCNP.

    Science.gov (United States)

    Colonna, N; Altieri, S

    2002-06-01

    The use of the simulation tool GEANT for neutron transport at energies below 20 MeV is discussed, in particular with regard to shielding and dose calculations. The reliability of the GEANT/MICAP package for neutron transport in a wide energy range has been verified by comparing the results of simulations performed with this package in a wide energy range with the prediction of MCNP-4B, a code commonly used for neutron transport at low energy. A reasonable agreement between the results of the two codes is found for the neutron flux through a slab of material (iron and ordinary concrete), as well as for the dose released in soft tissue by neutrons. These results justify the use of the GEANT/MICAP code for neutron transport in a wide range of applications, including health physics problems.

  3. Neutron Exposures in Human Cells: Bystander Effect and Relative Biological Effectiveness

    Science.gov (United States)

    Seth, Isheeta; Schwartz, Jeffrey L.; Stewart, Robert D.; Emery, Robert; Joiner, Michael C.; Tucker, James D.

    2014-01-01

    Bystander effects have been observed repeatedly in mammalian cells following photon and alpha particle irradiation. However, few studies have been performed to investigate bystander effects arising from neutron irradiation. Here we asked whether neutrons also induce a bystander effect in two normal human lymphoblastoid cell lines. These cells were exposed to fast neutrons produced by targeting a near-monoenergetic 50.5 MeV proton beam at a Be target (17 MeV average neutron energy), and irradiated-cell conditioned media (ICCM) was transferred to unirradiated cells. The cytokinesis-block micronucleus assay was used to quantify genetic damage in radiation-naïve cells exposed to ICCM from cultures that received 0 (control), 0.5, 1, 1.5, 2, 3 or 4 Gy neutrons. Cells grown in ICCM from irradiated cells showed no significant increase in the frequencies of micronuclei or nucleoplasmic bridges compared to cells grown in ICCM from sham irradiated cells for either cell line. However, the neutron beam has a photon dose-contamination of 5%, which may modulate a neutron-induced bystander effect. To determine whether these low doses of contaminating photons can induce a bystander effect, cells were irradiated with cobalt-60 at doses equivalent to the percent contamination for each neutron dose. No significant increase in the frequencies of micronuclei or bridges was observed at these doses of photons for either cell line when cultured in ICCM. As expected, high doses of photons induced a clear bystander effect in both cell lines for micronuclei and bridges (pbystander effect in these cells. Finally, neutrons had a relative biological effectiveness of 2.0±0.13 for micronuclei and 5.8±2.9 for bridges compared to cobalt-60. These results may be relevant to radiation therapy with fast neutrons and for regulatory agencies setting standards for neutron radiation protection and safety. PMID:24896095

  4. Monte Carlo simulation of neutron irradiation facility developed for accelerator based in vivo neutron activation measurements in human hand bones

    International Nuclear Information System (INIS)

    Aslam; Prestwich, W.V.; McNeill, F.E.; Waker, A.J.

    2006-01-01

    The neutron irradiation facility developed at the McMaster University 3 MV Van de Graaff accelerator was employed to assess in vivo elemental content of aluminum and manganese in human hands. These measurements were carried out to monitor the long-term exposure of these potentially toxic trace elements through hand bone levels. The dose equivalent delivered to a patient during irradiation procedure is the limiting factor for IVNAA measurements. This article describes a method to estimate the average radiation dose equivalent delivered to the patient's hand during irradiation. The computational method described in this work augments the dose measurements carried out earlier [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724]. This method employs the Monte Carlo simulation of hand irradiation facility using MCNP4B. Based on the estimated dose equivalents received by the patient hand, the proposed irradiation procedure for the IVNAA measurement of manganese in human hands [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724] with normal (1 ppm) and elevated manganese content can be carried out with a reasonably low dose of 31 mSv to the hand. Sixty-three percent of the total dose equivalent is delivered by non-useful fast group (>10 keV); the filtration of this neutron group from the beam will further decrease the dose equivalent to the patient's hand

  5. Long distance elementary measurement of the radiation dose ratio produced by neutron activation

    International Nuclear Information System (INIS)

    Zhou Changgeng; Lou Benchao; Wu Chunlei; Hu Yonghong; Li Yan

    2009-04-01

    The working principle and the structure and performances of a long distance controllable individual radiation dose ratio instrument are described. The radiation dose ratio produced by neutron activation is elementarily measured by using this instrument in the neutron generator hall with high neutron yield. When neutron yield arrives to 2 x 10 11 s -1 , the radiation dose ratio produced by neutron activation is 99.9 μSv/h in 1 h after the generator being stopped. The radiation dose ratio is reduced to 24.4 μSv/h in 39 h after the generator being stopped. When neutron yield is 3.2 x 10 10 s -1 , the radiation dose ratio produced by neutron activation is 21.9 μSv/h in 36 min, after the generator being stopped. The measurement results may provide reference for physical experimenters and neutron generator operators. (authors)

  6. Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia

    Science.gov (United States)

    Bortolussi, S.; Protti, N.; Ferrari, M.; Postuma, I.; Fatemi, S.; Prata, M.; Ballarini, F.; Carante, M. P.; Farias, R.; González, S. J.; Marrale, M.; Gallo, S.; Bartolotta, A.; Iacoviello, G.; Nigg, D.; Altieri, S.

    2018-01-01

    University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been carried out, aimed at characterizing the neutron spectrum and the gamma dose component. The neutron spectrum has been measured by means of multifoil neutron activation spectrometry and a least squares unfolding algorithm; gamma dose was measured using alanine dosimeters. Results show that in a reference position the thermal neutron flux is (1.20 ± 0.03) ×1010 cm-2 s-1 when the reactor is working at the maximum power of 250 kW, with the epithermal and fast components, respectively, 2 and 3 orders of magnitude lower than the thermal component. The ratio of the gamma dose with respect to the thermal neutron fluence is 1.2 ×10-13 Gy/(n/cm2).

  7. SU-F-T-672: A Novel Kernel-Based Dose Engine for KeV Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    Reinhart, M; Fast, M F; Nill, S; Oelfke, U [The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2016-06-15

    Purpose: Mimicking state-of-the-art patient radiotherapy with high precision irradiators for small animals allows advanced dose-effect studies and radiobiological investigations. One example is the implementation of pre-clinical IMRT-like irradiations, which requires the development of inverse planning for keV photon beams. As a first step, we present a novel kernel-based dose calculation engine for keV x-rays with explicit consideration of energy and material dependencies. Methods: We follow a superposition-convolution approach adapted to keV x-rays, based on previously published work on micro-beam therapy. In small animal radiotherapy, we assume local energy deposition at the photon interaction point, since the electron ranges in tissue are of the same order of magnitude as the voxel size. This allows us to use photon-only kernel sets generated by MC simulations, which are pre-calculated for six energy windows and ten base materials. We validate our stand-alone dose engine against Geant4 MC simulations for various beam configurations in water, slab phantoms with bone and lung inserts, and on a mouse CT with (0.275mm)3 voxels. Results: We observe good agreement for all cases. For field sizes of 1mm{sup 2} to 1cm{sup 2} in water, the depth dose curves agree within 1% (mean), with the largest deviations in the first voxel (4%) and at depths>5cm (<2.5%). The out-of-field doses at 1cm depth agree within 8% (mean) for all but the smallest field size. In slab geometries, the mean agreement was within 3%, with maximum deviations of 8% at water-bone interfaces. The γ-index (1mm/1%) passing rate for a single-field mouse irradiation is 71%. Conclusion: The presented dose engine yields an accurate representation of keV-photon doses suitable for inverse treatment planning for IMRT. It has the potential to become a significantly faster yet sufficiently accurate alternative to full MC simulations. Further investigations will focus on energy sampling as well as calculation

  8. Manufacturing of thermal neutron sensor using pMOS

    International Nuclear Information System (INIS)

    Lee, Nam Ho; Kim, Seung Ho

    2005-05-01

    A pMOSFET sensor having a Gadolinium converter has been invented successfully as a slow neutron sensor that is sensitive to neutron energy down to 0.025 eV. The Gd layer converts low energy neutrons to ionizing radiation of which the amount is proportional to neutron dose. Ionising radiation from neutron reactions changes the charge state of the gate oxide of the pMOSFET. The Gd-pMOSFETs were tested at a neutron beam port of HANARO research reactor and a 60 CO irradiation facility to investigate slow neutron response and gamma response, respectively. The voltage change was proportional to the accumulated slow neutron dose. The results from Gd coupled MOSFET neutron dosemeters shows an excellent sensitivity (15 - 16mV/cGy) and linearity to thermal neutrons with negligible background contamination. The results demonstrate the outstanding performance of the Gd coupled MOSFET neutron dosemeters clearly. The Gd-pMOSFET can also be used in a mixed radiation field by subtracting the voltage change of a pMOSFET without Gd from that of the Gd-pMOSFET

  9. Extended use of alanine irradiated in experimental reactor for combined gamma- and neutron-dose assessment by ESR spectroscopy and thermal neutron fluence assessment by measurement of (14)C by LSC.

    Science.gov (United States)

    Bartoníček, B; Kučera, J; Světlík, I; Viererbl, L; Lahodová, Z; Tomášková, L; Cabalka, M

    2014-11-01

    Gamma- and neutron doses in an experimental reactor were measured using alanine/electron spin resonance (ESR) spectrometry. The absorbed dose in alanine was decomposed into contributions caused by gamma and neutron radiation using neutron kerma factors. To overcome a low sensitivity of the alanine/ESR response to thermal neutrons, a novel method has been proposed for the assessment of a thermal neutron flux using the (14)N(n,p) (14)C reaction on nitrogen present in alanine and subsequent measurement of (14)C by liquid scintillation counting (LSC). Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A neutron detector for measurement of total neutron production cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Sekharan, K K; Laumer, H; Kern, B D; Gabbard, F [Kentucky Univ., Lexington (USA). Dept. of Physics and Astronomy

    1976-03-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight /sup 10/BF/sub 3/ counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from /sup 7/Li(p, n)/sup 7/Be. By adjusting the radial positions of the BF/sub 3/ counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from /sup 51/V(p, n)/sup 51/Cr and /sup 57/Fe(p, n)/sup 57/Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given.

  11. Monitor units are not predictive of neutron dose for high-energy IMRT

    Directory of Open Access Journals (Sweden)

    Hälg Roger A

    2012-08-01

    Full Text Available Abstract Background Due to the substantial increase in beam-on time of high energy intensity-modulated radiotherapy (>10 MV techniques to deliver the same target dose compared to conventional treatment techniques, an increased dose of scatter radiation, including neutrons, is delivered to the patient. As a consequence, an increase in second malignancies may be expected in the future with the application of intensity-modulated radiotherapy. It is commonly assumed that the neutron dose equivalent scales with the number of monitor units. Methods Measurements of neutron dose equivalent were performed for an open and an intensity-modulated field at four positions: inside and outside of the treatment field at 0.2 cm and 15 cm depth, respectively. Results It was shown that the neutron dose equivalent, which a patient receives during an intensity-modulated radiotherapy treatment, does not scale with the ratio of applied monitor units relative to an open field irradiation. Outside the treatment volume at larger depth 35% less neutron dose equivalent is delivered than expected. Conclusions The predicted increase of second cancer induction rates from intensity-modulated treatment techniques can be overestimated when the neutron dose is simply scaled with monitor units.

  12. A study of radiation vulnerability of ferroelectric material and devices

    International Nuclear Information System (INIS)

    Coiec, Y.M.; Musseau, O.; Leray, J.L.

    1994-01-01

    The radiation effects on ferroelectric material and devices are presented, based on commercially available samples. After recalling the background, effects in ferroelectric PZT capacitors are presented, concerning dose, neutrons and fatigue associated with dose effects. Physical implications and interpretations are sketched. In a second stage, effects are studied at the complete non-volatile RAM device level. Vulnerability in dose, dose rate and neutron fluence of commercial 4 kbit ferroelectric RAM is addressed. 64 kbit results are mentioned in dose rate. These results are compared to previously published data from other manufacturers or laboratories and supplement them. In the appendix, equivalence between rad(Si) and rad (PZT) is discussed in the case of low energy ''10 keV Aracor'' x-rays and 60 Co gamma rays

  13. Neutron dose and energy spectra measurements at Savannah River Plant

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Soldat, K.L.; Haggard, D.L.; Faust, L.G.; Tomeraasen, P.L.

    1987-08-01

    Because some workers have a high potential for significant neutron exposure, the Savannah River Plant (SRP) contracted with Pacific Northwest Laboratory (PNL) to verify the accuracy of neutron dosimetry at the plant. Energy spectrum and neutron dose measurements were made at the SRP calibrations laboratory and at several other locations. The energy spectra measurements were made using multisphere or Bonner sphere spectrometers, 3 He spectrometers, and NE-213 liquid scintillator spectrometers. Neutron dose equivalent determinations were made using these instruments and others specifically designed to determine dose equivalent, such as the tissue equivalent proportional counter (TEPC). Survey instruments, such as the Eberline PNR-4, and the thermoluminescent dosimeter (TLD)-albedo and track etch dosimeters (TEDs) were also used. The TEPC, subjectively judged to provide the most accurate estimation of true dose equivalent, was used as the reference for comparison with other devices. 29 refs., 43 figs., 13 tabs

  14. Study on the dose distribution of the mixed field with thermal and epi-thermal neutrons for neutron capture therapy

    International Nuclear Information System (INIS)

    Kobayashi, Tooru; Sakurai, Yoshinori; Kanda, Keiji

    1994-01-01

    Simulation calculations using DOT 3.5 were carried out in order to confirm the characteristics of depth-dependent dose distribution in water phantom dependent on incident neutron energy. The epithermal neutrons mixed to thermal neutron field is effective improving the thermal neutron depth-dose distribution for neutron capture therapy. A feasibility study on the neutron energy spectrum shifter was performed using ANISN-JR for the KUR Heavy Water Facility. The design of the neutron spectrum shifter is feasible, without reducing the performance as a thermal neutron irradiation field. (author)

  15. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  16. Induction of micronuclei by irradiation with neutrons produced from 600 MeV protons

    CERN Document Server

    Diehl-Marshall, I

    1980-01-01

    Chromosome damage can be detected by the observation of micronuclei . Because its sensitivity, the micronuclei induciton in meristems of Vicia faba bean roots has been selected to determine the radiation damage produced by doses ranging from 1 to 82 cGy of neutrons. The average number of miconuclei found between 24 and 48 hours after irradiation was plotted as a funciton of dose. The RBE values, using as reference radiation 60 Co y-rays, ranged from 3.5 for a neutron dose of 82 cGy to 18 for a neutron of 1 cGy. Even higher RBE values were deduced at low doses from the evaluation of cells containing multiple micronuclei.

  17. Evaluation of the {sup 239}Pu prompt fission neutron spectrum induced by neutrons of 500 keV and associated covariances

    Energy Technology Data Exchange (ETDEWEB)

    Neudecker, D., E-mail: dneudecker@lanl.gov [Theoretical Division, Los Alamos National Laboratory, P.O. Box 1663, MS-B283, NM 87545 (United States); Talou, P., E-mail: talou@lanl.gov [Theoretical Division, Los Alamos National Laboratory, P.O. Box 1663, MS-B283, NM 87545 (United States); Kawano, T., E-mail: kawano@lanl.gov [Theoretical Division, Los Alamos National Laboratory, P.O. Box 1663, MS-B283, NM 87545 (United States); Smith, D.L., E-mail: donaldlarnedsmith@gmail.com [Nuclear Engineering Division, Argonne National Laboratory, 1710 Avenida del Mundo #1506, Coronado, CA 92118 (United States); Capote, R., E-mail: r.capotenoy@iaea.org [Nuclear Data Section, International Atomic Energy Agency Vienna, Vienna International Centre, P.O. Box 100, A-1400 Vienna (Austria); Rising, M.E., E-mail: mrising@lanl.gov [X-Division, Los Alamos National Laboratory, P.O. Box 1663, MS-F663, NM 87545 (United States); Kahler, A.C., E-mail: akahler@lanl.gov [Theoretical Division, Los Alamos National Laboratory, P.O. Box 1663, MS-B283, NM 87545 (United States)

    2015-08-11

    We present evaluations of the prompt fission neutron spectrum (PFNS) of {sup 239}Pu induced by 500 keV neutrons, and associated covariances. In a previous evaluation by Talou et al. (2010), surprisingly low evaluated uncertainties were obtained, partly due to simplifying assumptions in the quantification of uncertainties from experiment and model. Therefore, special emphasis is placed here on a thorough uncertainty quantification of experimental data and of the Los Alamos model predicted values entering the evaluation. In addition, the Los Alamos model was extended and an evaluation technique was employed that takes into account the qualitative differences between normalized model predicted values and experimental shape data. These improvements lead to changes in the evaluated PFNS and overall larger evaluated uncertainties than in the previous work. However, these evaluated uncertainties are still smaller than those obtained in a statistical analysis using experimental information only, due to strong model correlations. Hence, suggestions to estimate model defect uncertainties are presented, which lead to more reasonable evaluated uncertainties. The calculated k{sub eff} of selected criticality benchmarks obtained with these new evaluations agree with each other within their uncertainties despite the different approaches to estimate model defect uncertainties. The k{sub eff} one standard deviations overlap with some of those obtained using ENDF/B-VII.1, albeit their mean values are further away from unity. Spectral indexes for the Jezebel critical assembly calculated with the newly evaluated PFNS agree with the experimental data for selected (n,γ) and (n,f) reactions, and show improvements for high-energy threshold (n,2n) reactions compared to ENDF/B-VII.1.

  18. IOP Shape coexistence in neutron-rich strontium isotopes at N = 60

    CERN Document Server

    Clément, Emmanuel

    2017-01-01

    The structure of neutron-rich $^{96,98}$ Sr nuclei was investigated by low-energy Coulomb excitation of radioactive beams at the REX-ISOLDE facility, CERN, with the MINIBALL spectrometer. A rich set of transitional and diagonal E2 matrix elements has been extracted from the differential Coulomb-excitation cross sections. The results support the scenario of a shape transition at N=60, giving rise to the coexistence of a highly deformed prolate and a spherical configuration in $^{98}$ Sr with low configuration mixing.

  19. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    Science.gov (United States)

    Forouzan, Faezeh; Waker, Anthony J

    2018-01-10

    The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was investigated over a range of 20 keV (X-ray) to 0.661 MeV (Cs-137 gamma ray). Then, with both the counters used simultaneously, the neutron and gamma ray doses produced by a P385 Neutron Generator (Thermo Fisher Scientific) together with a Cs-137 gamma source were determined. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Estimation dose of secondary neutrons in proton therapy

    International Nuclear Information System (INIS)

    Urban, T.

    2014-01-01

    Most of proton therapy centers for cancer treatment are still based on the passive scattering, in some of them there is system of the active scanning installed as well. The aim of this study is to compare secondary neutron doses in and around target volumes in proton therapy for both treatment techniques and for different energies and profile of incident proton beam. The proton induced neutrons have been simulated in the very simple geometry of tissue equivalent phantom (imitate the patient) and scattering and scanning nozzle, respectively. In simulations of the scattering nozzle, different types of scattering filters and brass collimators have been used as well. 3D map of neutron doses in and around the chosen/potential target volume in the phantom/patient have been evaluated and compared in the context of the dose deposited in the target volume. Finally, the simulation results have been compared with published data. (author)

  1. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  2. Study on the aligned uranium-235 nuclear decay in the neutron energy range of 1.7 eV - 2.15 keV

    International Nuclear Information System (INIS)

    Danelyan, L.S.; Zakharov, Yu.V.; Zykov, V.M.; Mostovoj, V.I.; Stolyarov, V.A.; Biryukov, S.A.; Zysina, N.Yu.; Osochnikov, A.A.; Svettsov, A.V.

    1983-01-01

    Using a time-of-flight neutron spectrometer comparative measurements of intensity of fission reaction on the aligned and non-oriented uranium-235 nuclei have been performed in order to identify the resonances caused by p-neutron capture as well as to determine the p-neutron contribution to the fission cross section in the region of unresolved resonances. In some isolated resonances differences in cross sections on aligned and non-oriented nuclei of about 10% have been observed which can permit to assi.on them to p-resonances. In the region of unresolved resonances in the 0.15-2.15 keV neutron energy range to the accuracy +-1% no changes in the fission cross section during the nuclear alignment have been observ

  3. Neutron Dose Measurement Using a Cubic Moderator

    International Nuclear Information System (INIS)

    Sheinfeld, M.; Mazor, T.; Cohen, Y.; Kadmon, Y.; Orion, I.

    2014-01-01

    The Bonner Sphere Spectrometer (BSS), introduced In July 1960 by a research group from Rice University, Texas, is a major approach to neutron spectrum estimation. The BSS, also known as multi-sphere spectrometer, consists of a set of a different diameters polyethylene spheres, carrying a small LiI(Eu) scintillator in their center. What makes this spectrometry method such widely used, is its almost isotropic response, covering an extraordinary wide range of energies, from thermal up to even hundreds of MeVs. One of the most interesting and useful consequences of the above study is the 12'' sphere characteristics, as it turned out that the response curve of its energy dependence, have a similar shape compared with the neutron's dose equivalent as a function of energy. This inexplicable and happy circumstance makes it virtually the only monitoring device capable providing realistic neutron dose estimates over such a wide energy range. However, since the detection mechanism is not strictly related to radiation dose, one can expect substantial errors when applied to widely different source conditions. Although the original design of the BSS included a small 4mmx4mmO 6LiI(Eu) scintillator, other thermal neutron detectors has been used over the years: track detectors, activation foils, BF3 filled proportional counters, etc. In this study we chose a Boron loaded scintillator, EJ-254, as the thermal neutron detector. The neutron capture reaction on the boron has a Q value of 2.78 MeV of which 2.34 MeV is shared by the alpha and lithium particles. The high manufacturing costs, the encasement issue, the installation efficiency and the fabrication complexity, led us to the idea of replacing the sphere with a cubic moderator. This article describes the considerations, as well as the Monte-Carlo simulations done in order to examine the applicability of this idea

  4. Shape Evolution in Neutron-Rich Krypton Isotopes Beyond N=60: First Spectroscopy of ^{98,100}Kr.

    Science.gov (United States)

    Flavigny, F; Doornenbal, P; Obertelli, A; Delaroche, J-P; Girod, M; Libert, J; Rodriguez, T R; Authelet, G; Baba, H; Calvet, D; Château, F; Chen, S; Corsi, A; Delbart, A; Gheller, J-M; Giganon, A; Gillibert, A; Lapoux, V; Motobayashi, T; Niikura, M; Paul, N; Roussé, J-Y; Sakurai, H; Santamaria, C; Steppenbeck, D; Taniuchi, R; Uesaka, T; Ando, T; Arici, T; Blazhev, A; Browne, F; Bruce, A; Carroll, R; Chung, L X; Cortés, M L; Dewald, M; Ding, B; Franchoo, S; Górska, M; Gottardo, A; Jungclaus, A; Lee, J; Lettmann, M; Linh, B D; Liu, J; Liu, Z; Lizarazo, C; Momiyama, S; Moschner, K; Nagamine, S; Nakatsuka, N; Nita, C; Nobs, C R; Olivier, L; Orlandi, R; Patel, Z; Podolyák, Zs; Rudigier, M; Saito, T; Shand, C; Söderström, P A; Stefan, I; Vaquero, V; Werner, V; Wimmer, K; Xu, Z

    2017-06-16

    We report on the first γ-ray spectroscopy of low-lying states in neutron-rich ^{98,100}Kr isotopes obtained from ^{99,101}Rb(p,2p) reactions at ∼220  MeV/nucleon. A reduction of the 2_{1}^{+} state energies beyond N=60 demonstrates a significant increase of deformation, shifted in neutron number compared to the sharper transition observed in strontium and zirconium isotopes. State-of-the-art beyond-mean-field calculations using the Gogny D1S interaction predict level energies in good agreement with experimental results. The identification of a low-lying (0_{2}^{+}, 2_{2}^{+}) state in ^{98}Kr provides the first experimental evidence of a competing configuration at low energy in neutron-rich krypton isotopes consistent with the oblate-prolate shape coexistence picture suggested by theory.

  5. Gamma-ray emission spectra from spheres with 14 MeV neutron source

    International Nuclear Information System (INIS)

    Yamamoto, Junji; Kanaoka, Takeshi; Murata, Isao; Takahashi, Akito; Sumita, Kenji

    1989-01-01

    Energy spectra of neutron-induced gamma-rays emitted from spherical samples were measured using a 14 MeV neutron source. The samples in use were LiF, Teflon:(CF 2 ) n , Si, Cr, Mn, Co, Cu, Nb, Mo, W and Pb. A diameter of the sphere was either 40 or 60 cm. The gamma-ray energy in the emission spectra covered the range from 500 keV to 10 MeV. Measured spectra were compared with transport calculations using the nuclear data files of JENDL-3T and ENDF/B-IV. The agreements between the measurements and the JENDL-3T calculations were good in the emission spectra for the low energy gamma-rays from inelastic scattering. (author)

  6. The development of BH3105E type neutron dose-equivalent meter

    International Nuclear Information System (INIS)

    Ji Changsong; Wang Tingting; Zhang Shuheng; Tan Baozeng

    2011-01-01

    A new BH3105E Type Neutron Dose-equivalent Meter has been developed. The 'multi-stick' ab- sorption method is used for thermal -14 MeV neutron equal dose-equivalent detection, what gives a high neutron sensitivity of 5 cps/μSv · h-1. RS-232 interface is accepted for signal communication (authors)

  7. Measurements of {sup 60}Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999

    Energy Technology Data Exchange (ETDEWEB)

    Gasparro, J.; Hult, M. E-mail: mikael.hult@irmm.jrc.be; Komura, K.; Arnold, D.; Holmes, L.; Johnston, P.N.; Laubenstein, M.; Neumaier, S.; Reyss, J.-L.; Schillebeeckx, P.; Tagziria, H.; Van Britsom, G.; Vasselli, R

    2004-07-01

    Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes {gamma}-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring {sup 60}Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from {sup 60}Co activity is in agreement with previous measurements using the short-lived radionuclides {sup 51}Cr and {sup 59}Fe. Limits on contamination of the samples with {sup 60}Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using {sup 60}Co activation.

  8. Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code

    CERN Document Server

    Paganini, S

    2005-01-01

    Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from Galactic cosmic radiation. Crews of future high-speed commercial flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the male adult voxels phantom MAX, developed in the Nuclear Energy Department of Pernambuco Federal University in Brazil, has been coupled with the Monte Carlo simulation code GEANT4. This toolkit, distributed and upgraded from the international scientific community of CERN/Switzerland, simulates thermal to ultrahigh energy neutrons transport and interactions in the matter. The high energy neutrons are pointed as the component that contribute about 70% of the neutron effective dose that represent the 35% to 60% total dose at aircraft altitude. In this research calculations of conversion coefficients from fluence to effective dose are performed for neutrons of energies from 100 MeV ...

  9. Study of dose distribution in dental radiology using the Monte Carlo Simulation; Estudo da distribuicao de dose em radiologia odontologica usando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S P.J.; Braz, D; Lopes, R T [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Anjos, M J [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica; Barroso, R C.S. [Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica

    2003-11-15

    Full text: The purpose of this study was to study the absorbed dose in mouth due to scattering in teeth in dental radiography using the monte carlo simulation. The Electron Gamma Shower (EGS-4) system of computer codes was used, which is a general purpose package for monte carlo simulation of the coupled transport of electrons and photons in an arbitrary geometry for particles with energies above a few keV up to several TeV. In the case of a X ray dental the low energy photons beam, are removed of the spectrum by the filtration. These low energy photons beam do not contribute in the obtaining of the radiographic image, but they will be contribute in the dose to the patient, however when the incident radiation crosses the tooth it generates a scattering radiation that contributes in the dose received by the patient in the oral cavity (cheek, tooth and oral cavity). Dental radiography is one of the largest single groups of radiographic examination accounting for 32% of radiographs taken in the Brazil. A number of relatively recent improvements in technology, equipment and techniques have the potential to reduce patient radiation dose and improve image quality. To optimize radiation protection all reasonable means should be employed to minimize the dose of each exposure. Dentists therefore need to keep up to date with changes in techniques and equipment and modify their own practice. In preliminary analysis could be notice that the energy below the 30 keV (low energy) is deposited in the cheek. To 30 keV photons there is the maximum absorbed energy in the tooth (about 60%). In 40 keV could be notice that deposited energy is same to teeth and cheek, but up to 40 keV just a small part of energy is deposited, e.g., the great part of energy is transmitted to the inner mouth (oral cavity). (orig.)

  10. Results of neutron dose measurements at the Rossendorf research reactors taking the actual neutron spectra into account

    International Nuclear Information System (INIS)

    Rimpler, A.; Kneschke, H.

    1985-01-01

    Based on a systematic evaluation of area dose studies at the beginning of the seventies, no individual routine neutron monitoring has been performed at the Rossendorf research reactors. To check this decision, a limited number of persons has been monitored with solid-state nuclear track detectors for several years. The dosemeters were calibrated on the basis of neutron spectra determined at the working places by means of the Bonner sphere method. Intermediate neutrons with a 1/E/sup α/ Fermi distribution were dominating. The fraction of fast neutrons was practically negligible. The obtained spectra, radiation, field quantities and results of individual dose measurements are presented. The dosemeter most appropriate for such neutron fields would be a 12-inch Bonner sphere rem counter. As the mean annual neutron exposure of research workers at the reactor amounted to only 2% of the maximum permissible dose, individual routine monitoring will, also in the future, not be neccessary. (author)

  11. Evaluation of gamma and neutron irradiation effects on the properties of mica film capacitors

    International Nuclear Information System (INIS)

    Roy, Rajesh; Pandya, Arun

    2005-01-01

    We present an investigation of gamma and neutron radiation effects on mica film capacitors from an electrical point of view. We have studied quantitatively the effects of gamma and neutron irradiation on mica film capacitors of thickness, 20 and 40 μm (0.7874 and 1.5748 mil) with two different areas, 01 and 04 cm 2 . The capacitance has been measured at room temperature in the frequency range 100 Hz-10 MHz. Negligible change in the capacitance due to high gamma dose of 60 Co, 15 kGy at dose rate 0.25 kGy/h, has been observed. However, appreciable change in the capacitance has been observed due to low doses of fast neutrons (cumulative dose, 115 cGy) with flux ∼ 9.925 X 10 7 neutrons/cm 2 h from 252 Cf neutron source of fluence, 2.5 x 10 7 neutrons/s. We have also observed that the impact of gamma and neutron irradiation is more at frequencies higher than 10 kHz, These results show that the mica capacitors do not show any radiation response below 10 kHz. The study shows the radiation response of mica film capacitors to gamma and fast neutron radiations. Mica capacitors show low gamma radiation response in comparison to fast neutron radiation, because a total dose of kGy order has been given by gamma source and only few cGy dose has been given by fast neutron source. (author)

  12. High energy resolution measurement of the sup 238 U neutron capture yield from 1 to 100 keV

    Energy Technology Data Exchange (ETDEWEB)

    Macklin, R.L. (Tennessee Univ., Knoxville, TN (United States). Dept. of Nuclear Engineering); Perez, R.B. (Tennessee Univ., Knoxville, TN (United States). Dept. of Nuclear Engineering Oak Ridge National Lab., TN (United States)); De Saussure, G.; Ingle, R.W. (Oak Ridge National Lab., TN (United States))

    1991-01-01

    The purpose of this work is the precise determination of the {sup 238}U neutron capture yield (i.e. the probability of neutron capture) as a function of neutron energy with the highest available neutron energy resolution. The motivation for this undertaking arises from the central role played by the {sup 238}U neutron capture process in the neutron balance of both thermal reactors and fast breeder reactors. The present measurement was performed using the Oak Ridge Electron Linear Accelerator (ORELA) facility. The pulsed beam of neutrons from the ORELA facility is collimated on a sample of {sup 238}U. The neutron capture rate in the sample is measured, as a function of neutron time-of-flight (TOF) by detecting the {gamma}-rays from the {sup 238}U(n, {gamma}){sup 239}U reaction with a large {gamma}-ray detector surrounding the {sup 238}U sample. At each energy, the capture yield is proportional to the observed capture rate divided by the measured intensity of the neutron beam. The constant of proportionality (the normalization constant) is obtained from the ratio of theoretical to experimentally measured areas under small {sup 238}U resonances where the resonance parameters have been determined from high-resolution {sup 238}U transmission measurements. The cross section for the reaction {sup 238}U(n,{gamma}){sup 239}U can be derived from the measured capture yield if one applies appropriate corrections for multiple scattering and resonance self-shielding. Some 200 {sup 238}U neutron resonances in the energy range from 250 eV to 10 keV have been observed which had not been detected in previous measurements. (author).

  13. Dose inhomogeneities for photons and neutrons near interfaces

    International Nuclear Information System (INIS)

    Broerse, J. J.; Zoetelief, J.

    2004-01-01

    Perturbations of charged particle equilibrium (CPE) at interfaces of materials of different atomic composition can lead to considerable differences in the energy deposition by photons and neutrons. Specific examples of these interface perturbations are encountered during irradiation of body cavities and soft tissue adjacent to bone or metallic implants and irradiation of cells in monolayer on the bottom of culture dishes. Another example is the build-up of CPE at air-tissue interfaces, referred to in radiotherapy as the skin sparing effect. For photon irradiation excess production of secondary electrons in high-Z materials, such as glass, bone or gold, will induce appreciably higher doses and decreased cell survival compared to the equilibrium situation. The energy dissipation of fast neutrons in biological materials occurs through recoil protons, heavy recoil nuclei and products of nuclear reactions. Owing to the large contribution from recoil protons to the neutron kerma, the hydrogen content of the biological material mainly determines the energy deposition. For neutron irradiation of cells in monolayer, CPE can be established or deliberately avoided by mounting tissue-equivalent plastic or carbon discs in front of the cells, respectively. This approach makes it possible to distinguish the biological effects of the low- and high-LET radiation components. (authors)

  14. Equivalent-spherical-shield neutron dose calculations

    International Nuclear Information System (INIS)

    Russell, G.J.; Robinson, H.

    1988-01-01

    Neutron doses through 162-cm-thick spherical shields were calculated to be 1090 and 448 mrem/h for regular and magnetite concrete, respectively. These results bracket the measured data, for reinforced regular concrete, of /approximately/600 mrem/h. The calculated fraction of the high-energy (>20 MeV) dose component also bracketed the experimental data. The measured and calculated doses were for a graphite beam stop bombarded with 100 nA of 800-MeV protons. 6 refs., 2 figs., 1 tab

  15. First measurement of β-decay properties of the drip-line nucleus 60Ga

    International Nuclear Information System (INIS)

    Mazzocchi, C.; Janas, Z.

    2001-11-01

    By using the fusion-evaporation reaction 28 Si( 36 Ar,p3n) and spectroscopy of β-delayed γ rays and charged particles on mass-separated sources, β-decay properties of the neutron-deficient isotope 60 Ga were studied for the first time. The half-life of 60 Ga was determined to be 70(15) ms, and, based on β γγ coincidences, the isobaric-analogue state in 60 Zn was identified at 4851.9(7) keV. A semiempirical proton separation energy value of 70(70) keV was deduced for 60 Ga. The experimental results on half-life, mass excess, proton separation energy, and structure of the 60 Zn daughter states are discussed in comparison with various model predictions, including large scale shell model calculations. (orig.)

  16. Neutron cross section evaluations of europium isotopes in 1 keV - 30 MeV energy range. Format - validation - comparison; Evaluation de sections efficaces pour des neutrons incidents sur des isotopes d'europium aux energies 1 keV - 30 MeV. Format - validation - comparaison

    Energy Technology Data Exchange (ETDEWEB)

    Dossantos-Uzarralde, P.; Le Luel, C.; Bauge, E. [CEA Bruyeres le Chatel, 91 (France). Dept. de Physique Theorique et Appliquee

    2004-07-01

    This paper presents neutron cross section evaluations of Europium isotopes. The cross sections are evaluated in 1 keV - 30 MeV energy range for the isotopes {sup 146}Eu, {sup 147}Eu, {sup 148}Eu, {sup 149}Eu, {sup 150}Eu, {sup 151}Eu, {sup 152}Eu, {sup 153}Eu, {sup 154}Eu in their ground state. This evaluation includes cross section productions of the long life isomeric states. Special attention is put on the options used for the description of the files written in ENDF-6 format. The final issue is a proposal of a new breed of ENDF-6 formatted neutron activation file. (authors)

  17. Neutron and gamma dose and spectra measurements on the Little Boy replica

    International Nuclear Information System (INIS)

    Hoots, S.; Wadsworth, D.

    1984-01-01

    The radiation-measurement team of the Weapons Engineering Division at Lawrence Livermore National Laboratory (LLNL) measured neutron and gamma dose and spectra on the Little Boy replica at Los Alamos National Laboratory (LANL) in April 1983. This assembly is a replica of the gun-type atomic bomb exploded over Hiroshima in 1945. These measurements support the National Academy of Sciences Program to reassess the radiation doses due to atomic bomb explosions in Japan. Specifically, the following types of information were important: neutron spectra as a function of geometry, gamma to neutron dose ratios out to 1.5 km, and neutron attenuation in the atmosphere. We measured neutron and gamma dose/fission from close-in to a kilometer out, and neutron and gamma spectra at 90 and 30 0 close-in. This paper describes these measurements and the results. 12 references, 13 figures, 5 tables

  18. X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

    International Nuclear Information System (INIS)

    Wharton, C. J.; Seabury, E. H.; Chichester, D. L.; Caffrey, A. J.; Simpson, J.; Lemchak, M.

    2011-01-01

    Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

  19. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities

    International Nuclear Information System (INIS)

    Mansy, M.S.; Bashter, I.I.; El-Mesiry, M.S.; Habib, N.; Adib, M.

    2015-01-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5–133 keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named “QMNB” was developed in the “MATLAB” programming language to perform the required calculations. - Highlights: • Quasi-monoenergetic neutron beams in energy range from (1.5–133) keV. • Interference between the resonance and potential scattering amplitudes. • Epithermal neutron beams used in BNCT

  20. Re-evaluation of {sup 58}Ni and {sup 60}Ni resonance parameters in the neutron energy range thermal to 800 keV

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H.; Leal, L.C.; Guber, K.H.; Wiarda, D.; Arbanas, G. [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2009-07-01

    The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the experimental data. The systematic uncertainties of the experimental data, estimated from the preliminary analyses of the experimental database, were taken into account in the cross section covariance matrix (CSCM) for total, scattering, and capture cross sections. The diagonal elements of the CSCM were obtained by quadratic combination of the different components of the uncertainties. Because of a lack of experimental information, the energy correlations were not obtained, and a value of 0.5 was arbitrarily taken for all the CSCM nondiagonal elements. The average capture cross-sections are significantly smaller than those calculated form Endf/B7.0

  1. Neutron and X-ray emission studies in a low energy plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Zakaullah, M. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Murtaza, G. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Qamar, S. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Ahmad, I. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Beg, M.M. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics

    1996-03-01

    In a low energy Mather-type plasma focus energized by a single 32 {mu}F capacitor, the X-ray and neutron emission is investigated using time-integrated and time-resolved detectors. The X-ray emission profile has a width (FWHM) of 40-50 ns. The neutron emission profile is broader compared to the X-ray emission profile and also delayed by 30-40 ns. To identify different regimes of X-ray emission, an X-ray pin-hole camera along with different absorption filters is employed. While the X-ray emission is high within a narrow pressure range of 2.0-2.5 mbar, the neutron emission is intense for a wider range of 1.0-4.5 mbar. The intense X-ray emission seems to originate from the axially moving shock wave. These results also indicate rather different production mechanisms for X-ray and neutron emission. Also on comparing the X-ray images with Al(2 {mu}m), Al(5 {mu}m), Al(9 {mu}m) filters, we find that the bulk of X-rays from the focus filament have energies less than 2 keV. (orig.).

  2. Estimates of Health Detriments and Tissue Weighting Factors for Hong Kong Populations from Low Dose, Low Dose Rate and Low LET Ionising Radiation Exposure

    International Nuclear Information System (INIS)

    Lee, S.K.

    1998-01-01

    The total health detriments and the tissue weighting factors for the Hong Kong populations from low dose, low dose rate and low LET ionising radiation exposure are obtained according to the methodology recommended in ICRP Publication 60. The probabilities of fatal cancers for the general (ages 0-90) and working (ages 20-64) populations due to lifetime exposure at low dose and low dose rate are 4.9 x 10 -2 Sv -1 and 3.6 x 10 -2 Sv -1 respectively, comparing with the ICRP 60 estimates of 5.0 x 10 -2 Sv -1 and 4.0 x 10 -2 Sv -1 . The corresponding total health detriments for the general and working populations are 6.9 x 10 -2 Sv -1 and 4.9 x 10 -2 Sv -1 respectively comparing with the ICRP 60 estimates of 7.3 x 10 -2 Sv -1 and 5.6 x 10 -2 Sv -1 . Tissue weighting factors for the general population are 0.01 (bone surface and skin), 0.02 (liver, oesophagus and thyroid), 0.04 (bladder and breast), 0.08 (remainder), 0.10 (stomach), 0.11 (bone marrow), 0.15 (colon), 0.19 (lung) and 0.21 (gonads) and for the working population are 0.01 (bone surface and skin), 0.03 (liver, oesophagus and thyroid), 0.04 (breast), 0.06 (remainder), 0.07 (bladder), 0.08 (colon), 0.14 (bone marrow and stomach), 0.16 (lung) and 0.20 (gonads). (author)

  3. Measurement of the G-value for 1. 5 keV X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, J.P.; Schillaci, M.E.; Raju, M.R. (Los Alamos National Lab., NM (USA))

    1989-12-01

    Using a ferrous sulfate solution modified by the addition of benzoic acid, the authors measured relative G-values for Al{sub k} characteristic X-rays (1.5keV), {sup 238}Pu {alpha}-particles (3.7MeV), {sup 60}Co (1.17 MeV) and {sup 137}Cs (0.66 MeV){gamma}-rays. Relative ferrous-to-ferric conversions as a function of dose were similar for the two {gamma}-ray energies, yielding G-values of 1.62 and 1.59 {mu}mol J{sup -1} for the {sup 60}Co and {sup 137}Cs radiations. The {alpha}-particle G-value was 0.52 {mu}mol J{sup -1}, or 31% of that for {sup 60}Co {gamma}-rays. The Al{sub k} X-rays had a G-value of 0.92 {mu}mol J{sup -1} or 57% of that of the {sup 60}Co radiation. This G-value for 1.5 keV X-rays is within 20% of values predicted by current theories, and theoretical values are within the error range of the authors' measurements. (author).

  4. Calculation of quality factor for monoenergetic neutrons - in accordance with ICRU Report 40

    International Nuclear Information System (INIS)

    Bregadze, Y.I.; Maslyaev, P.F.; Nurlibaev, K.N.

    1988-01-01

    The quality factors for heavy particle dose in tissue from first interactions of monoenergetic neutrons calculated directly from the new quality factor determination given in ICRU Report 40 are presented as a function of neutron energy. The results of the calculation are compared with previously published calculations based on old concepts. For neutron energies from 100 keV up to 1 MeV these differences are about a factor of two. (author)

  5. Neutron spectrum and dose-equivalent in shuttle flights during solar maximum

    Energy Technology Data Exchange (ETDEWEB)

    Keith, J E; Badhwar, G D; Lindstrom, D J [National Aeronautics and Space Administration, Houston, TX (United States). Lyndon B. Johnson Space Center

    1992-01-01

    This paper presents unambiguous measurements of the spectrum of neutrons found in spacecraft during spaceflight. The neutron spectrum was measured from thermal energies to about 10 MeV using a completely passive system of metal foils as neutron detectors. These foils were exposed to the neutron flux bare, covered by thermal neutron absorbers (Gd) and inside moderators (Bonner spheres). This set of detectors was flown on three U.S. Space Shuttle flights, STS-28, STS-36 and STS-31, during the solar maximum. We show that the measurements of the radioactivity of these foils lead to a differential neutron energy spectrum in all three flights that can be represented by a power law, J(E){approx equal}E{sup -0.765} neutrons cm{sup -2} day {sup -1} MeV{sup -1}. We also show that the measurements are even better represented by a linear combination of the terrestrial neutron albedo and a spectrum of neutrons locally produced in a aluminium by protons, computed by a previous author. We use both approximations to the neutron spectrum to produce a worst case and most probable case for the neutron spectra and the resulting dose-equivalents, computed using ICRP-51 neutron fluence-dose conversion tables. We compare these to the skin dose-equivalents due to charged particles during the same flights. (author).

  6. Alpha decay of neutron-deficient isotopes with 5260 mu s) and /sup 110/Xe

    CERN Document Server

    Schardt, D; Kirchner, R; Klepper, O; Kurcewicz, W; Roeckl, E; Tidemand-Petersson, P

    1981-01-01

    Using /sup 58/Ni(/sup 58/Ni, xpyn) reactions and on-line mass separation, the alpha -decays of very neutron-deficient isotopes of tellurium, iodine, xenon and cesium were studied. The new isotopes /sup 106/Te (T/sub 1/2/=60/sub -10//sup +30/ mu s) and /sup 110/Xe were identified by their alpha -lines of 4160+or-30 keV and 3737+or-30 keV energy, respectively, with the genetic relationship between the two successive alpha -decays being verified experimentally, while for several other alpha -decaying isotopes more precise data were obtained. The observed alpha -decay properties are discussed within the systematics of energy and reduced width. (19 refs).

  7. Dose rates modeling of pressurized water reactor primary loop components with SCALE6.0

    International Nuclear Information System (INIS)

    Matijević, Mario; Pevec, Dubravko; Trontl, Krešimir

    2015-01-01

    Highlights: • Shielding analysis of the typical PWR primary loop components was performed. • FW-CADIS methodology was thoroughly investigated using SCALE6.0 code package. • Versatile ability of SCALE6.0/FW-CADIS for deep penetration models was proved. • The adjoint source with focus on specific material can improve MC modeling. - Abstract: The SCALE6.0 simulation model of a typical PWR primary loop components for effective dose rates calculation based on hybrid deterministic–stochastic methodology was created. The criticality sequence CSAS6/KENO-VI of the SCALE6.0 code package, which includes KENO-VI Monte Carlo code, was used for criticality calculations, while neutron and gamma dose rates distributions were determined by MAVRIC/Monaco shielding sequence. A detailed model of a combinatorial geometry, materials and characteristics of a generic two loop PWR facility is based on best available input data. The sources of ionizing radiation in PWR primary loop components included neutrons and photons originating from critical core and photons from activated coolant in two primary loops. Detailed calculations of the reactor pressure vessel and the upper reactor head have been performed. The efficiency of particle transport for obtaining global Monte Carlo dose rates was further examined and quantified with a flexible adjoint source positioning in phase-space. It was demonstrated that generation of an accurate importance map (VR parameters) is a paramount step which enabled obtaining Monaco dose rates with fairly uniform uncertainties. Computer memory consumption by the S N part of hybrid methodology represents main obstacle when using meshes with large number of cells together with high S N /P N parameters. Detailed voxelization (homogenization) process in Denovo together with high S N /P N parameters is essential for precise VR parameters generation which will result in optimized MC distributions. Shielding calculations were also performed for the reduced PWR

  8. Reduction of the secondary neutron dose in passively scattered proton radiotherapy, using an optimized pre-collimator/collimator

    International Nuclear Information System (INIS)

    Brenner, David J; Elliston, Carl D; Hall, Eric J; Paganetti, Harald

    2009-01-01

    Proton radiotherapy represents a potential major advance in cancer therapy. Most current proton beams are spread out to cover the tumor using passive scattering and collimation, resulting in an extra whole-body high-energy neutron dose, primarily from proton interactions with the final collimator. There is considerable uncertainty as to the carcinogenic potential of low doses of high-energy neutrons, and thus we investigate whether this neutron dose can be significantly reduced without major modifications to passively scattered proton beam lines. Our goal is to optimize the design features of a patient-specific collimator or pre-collimator/collimator assembly. There are a number of often contradictory design features, in terms of geometry and material, involved in an optimal design. For example, plastic or hybrid plastic/metal collimators have a number of advantages. We quantify these design issues, and investigate the practical balances that can be achieved to significantly reduce the neutron dose without major alterations to the beamline design or function. Given that the majority of proton therapy treatments, at least for the next few years, will use passive scattering techniques, reducing the associated neutron-related risks by simple modifications of the collimator assembly design is a desirable goal.

  9. Pre-assessment of dose rates of 134Cs, 137Cs, and 60Co for marine biota from discharge of Haiyang Nuclear Power Plant, China

    International Nuclear Information System (INIS)

    Li, Jingjing; Liu, Senlin; Zhang, Yongxing; Chen, Ling; Yan, Yuan; Cheng, Weiya; Lou, Hailin; Zhang, Yongbao

    2015-01-01

    Haiyang Nuclear Power Plant to be built in China was selected as a case for the dose pre-assessment for marine biota in this study. The concentrations of Cs and Co in organisms (turbot, yellow croaker, swimming crab, abalone, sea cucumber, and sea lettuce), seawater, and bottom sediment sampled on-site were measured by neutron activation analysis, and the site-specific transfer parameters (concentration ratios and distribution coefficients) of Cs and Co were calculated. 134 Cs, 137 Cs, and 60 Co activity concentrations in the organisms and the sediment at the site were calculated with the site-specific transfer parameters and the anticipated activity concentrations in the liquid effluent of the nuclear power plant. The ERICA tool was used to estimate the dose rates of 134 Cs, 137 Cs, and 60 Co to the selected organisms based on the biological models developed. The total dose rates of 134 Cs, 137 Cs, and 60 Co to the six organisms were all <0.001 μGy h −1 . - Highlights: • Pre-assessment for biota dose rates from Haiyang Nuclear Power Plant was made. • The site-specific transfer parameters were obtained by neutron activation analysis. • The dose rates of 134 Cs, 137 Cs, and 60 Co to the organisms were <0.001 μGy h −1

  10. Neutron dose measurements with the GSI ball at high energy accelerators

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Gutermuth, F.; Radon, T.; Kozlova, E.

    2005-01-01

    Full text: At high energy particle accelerators the production of neutron radiation dominates radiation protection. For the radiation survey at accelerators there is a need for reliable detection systems (passive radiation monitors), which can measure the dose for a wide range of neutron energies independently on the beam pulse structure of the produced radiation. In this work a passive neutron dosemeter for the measurement of the ambient dose equivalent is presented. The dosemeter is suitable for measurements of the emerging neutron radiation at accelerators for the whole energy range up to about 10 GeV. The dosemeter consists of a polyethylene sphere, TL elements (pairs of TLD600/700) and an additional lead layer (PE/Pb) in neutron fields at high energy accelerators is investigated in this work. Results of dose measurements which were performed in realistic neutron fields at the high energy accelerator SPS at CERN (CERF facility) and in Cave A at the heavy ion synchrotron SIS at GSI are presented. The results of these measurements are compared with the expected dose values from the neutron spectra determined for the measurement positions at CERF and in Cave A (FLUKA) and with the dosemeter response derived by the calculated response functions (FLUKA) folded with the neutron spectra. The comparisons show that the additional lead layer in the PE/Pb-sphere improves significantly the response of the dosemeter. The response of the PE/Pb-sphere is 40 to 50 % higher at CERF and Cave A in comparison to the bare PE-sphere. At CERF the dose values of the PE/Pb-sphere is about 25 % lower than the expected dose value, whilst for Cave A, a rather good agreement was found (2 % deviation). (author)

  11. Monte Carlo calculation for the development of a BNCT neutron source (1eV-10KeV) using MCNP code.

    Science.gov (United States)

    El Moussaoui, F; El Bardouni, T; Azahra, M; Kamili, A; Boukhal, H

    2008-09-01

    Different materials have been studied in order to produce the epithermal neutron beam between 1eV and 10KeV, which are extensively used to irradiate patients with brain tumors such as GBM. For this purpose, we have studied three different neutrons moderators (H(2)O, D(2)O and BeO) and their combinations, four reflectors (Al(2)O(3), C, Bi, and Pb) and two filters (Cd and Bi). Results of calculation showed that the best obtained assembly configuration corresponds to the combination of the three moderators H(2)O, BeO and D(2)O jointly to Al(2)O(3) reflector and two filter Cd+Bi optimize the spectrum of the epithermal neutron at 72%, and minimize the thermal neutron to 4% and thus it can be used to treat the deep tumor brain. The calculations have been performed by means of the Monte Carlo N (particle code MCNP 5C). Our results strongly encourage further studying of irradiation of the head with epithermal neutron fields.

  12. Comments on ICRP-60 rationale for dose limits for the pregnant worker

    International Nuclear Information System (INIS)

    Myers, D.K.

    1992-06-01

    ICRP Publication 60 has recently recommended new dose limits for the radiation exposure of pregnant workers. These new dose limits for pregnant workers are more restrictive than the current limits in force in Canada. Recent presentations by Dr. R.H. Mole have faulted the arguments provided by ICRP as justification for reducing the previously recommended limits for pregnant radiation workers. The present paper provides a brief review of the development of the human conceptus, of the biological effects of low doses of radiation on the foetus, and discusses R.H. Mole's comments on ICRP-60. On the critical issues concerning the presence or absence of threshold doses for induction of specific biological endpoints, Dr. Mole and ICRP-60 appear to be in agreement. The basic disagreement between Dr. Mole and ICRP-60 seems to revolve around the philosophical question of whether dose limits should be based on quantitative risks to the foetus or whether dose limits to the pregnant worker should provide a standard of protection to the foetus which is broadly comparable with that provided for members of the general public. Further research is recommended on one of the topics raised by Dr. Mole, namely, foetal doses from radionuclides inhaled or ingested by the mother

  13. Neutron dose rate for {sup 252} Cf AT source in medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Paredes, L.; Balcazar, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Francois, J.L. [FI-UNAM, 04510 Mexico D.F. (Mexico)

    2006-07-01

    The AAPM TG-43 modified protocol was used for the calculation of the neutron dose rate of {sup 252}Cf sources for two tissue substitute materials, five normal tissues and six tumours. The {sup 252}Cf AT source model was simulated using the Monte Carlo MCNPX code in spherical geometry for the following factors: a) neutron air kerma strength conversion factor, b) dose rate constant, c) radial dose function, d) geometry factor, e) anisotropy function and f) neutron dose rate. The calculated dose rate in water at 1 cm and 90 degrees from the source long axis, using the Watt fission spectrum, was D{sub n}(r{sub 0}, {theta}{sub 0})= 1.9160 cGy/h-{mu}g. When this value is compared with Rivard et al. calculation using MCNP4B code, 1.8730 cGy/h-{mu}g, a difference of 2.30% is obtained. The results for the reference neutron dose rate in other media show how small variations in the elemental composition between the tissues and malignant tumours, produce variations in the neutron dose rate up to 12.25%. (Author)

  14. Dose levels due to neutrons in the vicinity of high energy medical accelerators

    International Nuclear Information System (INIS)

    McGinley, P.H.; Wood, M.; Sohrabi, M.; Mills, M.; Rodriguez, R.

    1976-01-01

    High energy photons are generated for use in radiation therapy by the decelleration of electrons in metal targets. Fast neutrons are also generated as a result of (γ, n) and (e, e'n) interactions in the target, beam compensator filter, and collimator material. In this work the adsorbed dose to neutrons was measured at the center of a 10 x 10 cm photon beam and 5 cm outside of the beam edge for a number of treatment units. Dose levels due to slow and fast neutrons were also established outside of the treatment rooms and a Bonner sphere neutron spectrometer system was employed to determine the neutron energy spectrum due to stray neutron radiation at each accelerator. For the linac it was found that the neutron dose at the beam center was 0.0039% of the photon dose and values of 0.049% and 0.053% were observed for the Allis Chalmers betatron and the Brown Boveri Betatron. Dose equivalent rates in the range of 0.3 to 22.5 mrem/hr were measured for points outside the treatment rooms when the accelerators were operated at a photon dose rate of 100 rad/min at the treatment position

  15. Neutron capture widths of s-wave resonances in 56Fe, 5860Ni and 27Al

    International Nuclear Information System (INIS)

    Wisshak, K.; Kaeppeler, F.; Reffo, G.; Fabbri, F.

    1982-01-01

    The neutron capture widths of s-wave resonances in 56 Fe (27.7 keV), 58 Ni (15.4 keV), 60 Ni (12.5 keV) and 27 Al (35.3 keV) have been determined, using a setup completely different from LINAC experiments. A pulsed 3 MV Van de Graaff accelerator and the 7 Li(p,n) reaction served as a neutron source. The proton energy was adjusted just above the reaction threshold to obtain a kinematically collimated neutron beam. This allowed to position the samples at a flight path as short as approx. 90 mm. Capture events were detected by three Moxon-Rae detectors with graphite, bismuth-graphite and pure bismuth converter, respectively. The measurements were performed relative to a gold standard. The setup allows to discriminate capture of scattered neutrons completely by time of flight and to use very thin samples (0.15 mm) in order to reduce multiple scattering. After correction for deviations of the detector efficiency from a linear increase with gamma-ray energy, the results obtained with different detectors agree within their remaining systematic uncertainty of approx. 5%. Only preliminary results are presented

  16. Application of reactors for testing neutron-induced upsets in commercial SRAMs

    International Nuclear Information System (INIS)

    Griffin, P.J.; Luera, T.F.; Sexton, F.W.; Cooper, P.J.; Karr, S.G.; Hash, G.L.; Fuller, E.

    1997-01-01

    Reactor neutron environments can be used to test/screen the sensitivity of unhardened commercial SRAMs to low-LET neutron-induced upset. Tests indicate both thermal/epithermal (< 1 keV) and fast neutrons can cause upsets in unhardened parts. Measured upset rates in reactor environments can be used to model the upset rate for arbitrary neutron spectra

  17. Development Of A Method For Measurement Of Total Neutron Cross Sections Based On The Neutron Transmission Method Using A He-3 Counter On Filtered Neutron Beams At Dalat Research Reactor

    International Nuclear Information System (INIS)

    Tran Tuan Anh; Dang Lanh; Nguyen Canh Hai; Nguyen Xuan Hai; Pham Kien; Nguyen Thuy Nham; Pham Ngoc Son; Ho Huu Thang

    2007-01-01

    Determination of total neutron cross sections and average resonance parameters in the energy range from tens keV to hundreds keV is important for fast reactors calculations and designs because this energy range gives the most output of all neutron induced reactions in the spectrum of fast reactors. Besides, the total neutron cross section measurement is also one of the methods for determination of s, p and d-wave neutron strength functions. The purpose of this project is to develop a method for measurement of total neutron cross sections based on the neutron transmission technique using a He-3 counter. The average total neutron cross sections of 238 U were obtained from neutron transmission measurements on filtered neutron beams of 55 keV and 144 keV at the horizontal channel No.4 of the Dalat research reactor. The present results have been compared with the previous measurements, and the evaluated data from ENDF/B-6.8 library. (author)

  18. Enhancement of viability of radiosensitive (PBMC and resistant (MDA-MB-231 clones in low-dose-rate cobalt-60 radiation therapy

    Directory of Open Access Journals (Sweden)

    Patrícia Lima Falcão

    2015-06-01

    Full Text Available Abstract Objective: In the present study, the authors investigated the in vitro behavior of radio-resistant breast adenocarcinoma (MDA-MB-231 cells line and radiosensitive peripheral blood mononuclear cells (PBMC, as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy. Materials and Methods: The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed. Results: Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation. Conclusion: Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

  19. High dose neutron irradiation damage in beryllium as blanket material

    Energy Technology Data Exchange (ETDEWEB)

    Chakin, V.P. E-mail: fae@niiar.ru; Kazakov, V.A.; Teykovtsev, A.A.; Pimenov, V.V.; Shimansky, G.A.; Ostrovsky, Z.E.; Suslov, D.N.; Latypov, R.N.; Belozerov, S.V.; Kupriyanov, I.B. E-mail: vniinm.400@g23.relkom.ru

    2001-11-01

    The paper presents the investigation results of beryllium products that operated in the SM and BOR-60 reactors up to neutron doses of 2.8x10{sup 22} and 8.0x10{sup 22} cm{sup -2} (E>1 MeV), respectively. The calculated and experimental data are given on helium and tritium accumulation, swelling, micro-hardness and thermal conductivity. The microstructural investigation results of irradiated beryllium are also presented. It is shown that the rate of helium and tritium accumulation in beryllium in the SM and BOR-60 reactors is high enough, which is of interest from the viewpoint of modeling the working conditions of the DEMO fusion reactor. Swelling of beryllium at irradiation temperature of 70-150 deg. C and neutron fluence of 2.8x10{sup 22} cm{sup -2} (E>1 MeV) makes up 0.8-1.5%, at 400 deg. C and fluence of 8x10{sup 22} cm{sup -2} (E>1 MeV)-3.2-5.0%. Irradiation hardening and decrease of thermal conductivity strongly depend on the irradiation temperature and are more significant at reduced temperatures. All results presented in the paper were analyzed with due account of the supposed working parameters of the DEMO fusion reactor blanket.

  20. High dose neutron irradiation damage in beryllium as blanket material

    International Nuclear Information System (INIS)

    Chakin, V.P.; Kazakov, V.A.; Teykovtsev, A.A.; Pimenov, V.V.; Shimansky, G.A.; Ostrovsky, Z.E.; Suslov, D.N.; Latypov, R.N.; Belozerov, S.V.; Kupriyanov, I.B.

    2001-01-01

    The paper presents the investigation results of beryllium products that operated in the SM and BOR-60 reactors up to neutron doses of 2.8x10 22 and 8.0x10 22 cm -2 (E>1 MeV), respectively. The calculated and experimental data are given on helium and tritium accumulation, swelling, micro-hardness and thermal conductivity. The microstructural investigation results of irradiated beryllium are also presented. It is shown that the rate of helium and tritium accumulation in beryllium in the SM and BOR-60 reactors is high enough, which is of interest from the viewpoint of modeling the working conditions of the DEMO fusion reactor. Swelling of beryllium at irradiation temperature of 70-150 deg. C and neutron fluence of 2.8x10 22 cm -2 (E>1 MeV) makes up 0.8-1.5%, at 400 deg. C and fluence of 8x10 22 cm -2 (E>1 MeV)-3.2-5.0%. Irradiation hardening and decrease of thermal conductivity strongly depend on the irradiation temperature and are more significant at reduced temperatures. All results presented in the paper were analyzed with due account of the supposed working parameters of the DEMO fusion reactor blanket

  1. parity assignment of the pronounced structure in the radiative capture of neutrons by 238U below 100 keV

    International Nuclear Information System (INIS)

    Moore, M.S.; Corvi, F.; Mewissen, L.; Poortmans, F.

    1981-01-01

    Some years ago, Perez and de Saussure reported evidence for intermediate structure in the radiative capture cross sections of 238 U. More recently, these and additional data, obtained by a different experimental technique but which showed the same non-statistical behavior, were analyzed by Perez et al. Under the assumption that the structure could be attributed to doorway states in the p/sup 3/2/ neutron channel. The results of an experimental determination of the parity of the structure, using neutron capture-gamma ray spectroscopy are reported. Much of the structure below 50 keV appears to be due to s-wave interactions. The magnitude of the fluctuations is much larger than can be calculated with the usual unresolved - resonance treatment unless the average neutron and radiative-capture widths are correlated. It is shown that such an apparent correlation can arise as a result of multiple-scattering enhancement of radiative capture in the samples used, and it is concluded that the evidence for intermediate structure in the capture of neutrons by 238 U is not yet firmly established

  2. Experimental Determination of the Neutron Radiation-Dose Distribution in the Human Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Stipcic, Neda [Institute Rudjer Bogkovic, Zagreb, Yugoslavia (Serbia)

    1967-01-15

    The quality of the radiation delivering the radiation dose to the human phantom is quite different from that of the incident neutron beam. This paper describes the experimental investigation of the variation of neutron dose related to the variation of neutron fluence with depth in the human phantom. The distribution of neutron radiation was determined in the human phantom - a cube of paraffin wax 25 cm x 25 cm x 50 cm with a density of 0.92 cm{sup -3}. Po-Be and Ra-Be point sources were used as neutron sources. Neutron fluences were measured using different types of detector: scintillation detector, BF{sub 3} counter, and nuclear-track emulsions. Since the fluence measurements with these three types of detectors were carried out under the same experimental conditions, it was possible to separate and analyse each part of the radiation dose in the paraffin. From the investigations, the distribution of the total radiation dose was obtained as a function of the paraffin depth. The maximum value of this dose distribution is constant with respect to the distance between the source and the paraffin phantom. From the results obtained, some conclusions may be drawn concerning the amount of absorbed radiation dose in the human phantom. (author)

  3. The relative biological effectiveness of 60Co γ-rays, 55 kVp X-rays, 250 kVp X-rays, and 11 MeV electrons at low doses

    International Nuclear Information System (INIS)

    Spadinger, I.; Palcic, B.

    1992-01-01

    The RBE of selected low-LET radiation modalities (55 kVp X- rays, 250 kVp X-rays, 60 Co γ-rays, and 11 MeV electrons) was investigated for survival of two cell lines (V79 and CHO). Detailed measurements were made in the 0 to 3 Gy dose range using an image cytometry device to accurately determine the number of cells assayed at each dose point. Data were also collected in the high dose range (0 to 10 Gy) using conventional counting and plating techniques. RBE values (#+- #1 SE) varied from 1.0±0.07 (V79 cells) and 1.2± 0.05 (CHO cells) at high doses to 1.3±0.07 (V79) and 1.4±0.1 (CHO) at low doses for 55 kVp X-rays, from 1.1±0.05 (V79) and 1.1±0.04 (CHO) at high doses to 1.1±0.06 (V79) and 1.2±0.2 (CHO) at low doses for 250 kVp X-rays, and from 1.1±0.08 (V79) and 1.0±0.04 (CHO) at high doses to 1.0±0.06 (V79) and 0.9±0.1 (CHO) at low doses for 11 MeV electrons. Only the low and high dose RBEs for 55 kVp X-rays relative to 60 Co γ-rays were significantly different. (author)

  4. Effect of preliminary neutron irradiation on helium blistering of 0Kh16N15M3B steel

    International Nuclear Information System (INIS)

    Chernov, I.I.; Kalin, B.A.; Skorov, D.M.; Shishkin, G.N.; Ivanov, M.V.

    1982-01-01

    The method of electron microscopy has been applied to investigate the effect of preliminary neutron irradiation on the OKh16N15M3B steel blistering under irradiation by 20 keV helium ions with (1-10)x10 21 ion/m 2 doses at the temperature below 373 K. It is shown that neutron irradiation shifts critical doses of blister formation and intense scaling towards higher doses. But after the incubation period the erosion of steel preliminary neutron irradiated grows with the increase of helium ion dose above 7x10 21 ion/m 2 . Short-term heating of neutron irradiated samples during 15 min at 1173 K does not practically affect the beginning of intense scaling of the surface

  5. Experimental method research on neutron equal dose-equivalent detection

    International Nuclear Information System (INIS)

    Ji Changsong

    1995-10-01

    The design principles of neutron dose-equivalent meter for neutron biological equi-effect detection are studied. Two traditional principles 'absorption net principle' and 'multi-detector principle' are discussed, and on the basis of which a new theoretical principle for neutron biological equi-effect detection--'absorption stick principle' has been put forward to place high hope on both increasing neutron sensitivity of this type of meters and overcoming the shortages of the two traditional methods. In accordance with this new principle a brand-new model of neutron dose-equivalent meter BH3105 has been developed. Its neutron sensitivity reaches 10 cps/(μSv·h -1 ), 18∼40 times higher than that of all the same kinds of meters 0.23∼0.56 cps/(μSv·h -1 ), available today at home and abroad and the specifications of the newly developed meter reach or surpass the levels of the same kind of meters. Therefore the new theoretical principle of neutron biological equi-effect detection--'absorption stick principle' is proved to be scientific, advanced and useful by experiments. (3 refs., 3 figs., 2 tabs.)

  6. Resolved resonance parameters for uranium 238 from 4 to 6 keV

    International Nuclear Information System (INIS)

    Olsen, D.K.; Meszaros, P.S.

    1982-01-01

    Neutron widths for 145 resonances from 4 to 6 keV are reported from a least-squares shape analysis of the ORELA 150-m, 4-sample 238 U transmission data. The resultant s-wave strength function from 4 to 6 keV is found to be substantially smaller than that from 0 to 4 keV

  7. Neutrons at W 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Junker, J.; Weller, A.

    1998-10-01

    The W 7-X deuterium plasma (18 MW NI, 4 keV, 1.5.10{sup 20} m{sup -3}) will produce 6.10{sup 16} neutrons during a 10 s pulse. A detailed geometrical model of the W 7-X experiment has been set up for the neutron transport calculations by the MCNP4B code (Monte Carlo neutron particle). The fast neutron flux (2.5 MeV) inside the torus is 100 times higher than inside the hall. The almost homogeneous thermal neutron flux inside the hall is reduced 30 times by doping the concrete walls with 700 ppm of boron. For a pulse scenario of 500 pulses per year the annual dose equivalent rate outside of the hall is down to the legally allowed level of 0.3 mSv/year, mainly by photons, due to the shielding of a 1.8 m thick concrete wall. The skyshine by the flux penetrating the 1.2 m thick concrete roof leads to 0.01 mSv/year at the fence. The structure of the experiment gets activated by the neutrons which for the chosen pulse scenario leads to a total activity varying between 2.6.10{sup 9} and 1.2.10{sup 13} Bq. The dominant isotopes are the superconductor compound ({sup 28}Al, {sup 66}Cu, {sup 94m}Nb) on the short timescale (min`s) and the steel components ({sup 51}Cr, {sup 54}Mn, {sup 60}Co) on the long timescale (months and years). For the austenitic steel a concentration of 50 ppm of Co has been assumed. After 10 years lifetime of the experiment it takes 4.8 years until the long living {sup 60}Co (T{sub 1/2} = 5.3 years) becomes the dominant radioactive isotope. Having waited for totally 10 years the specific activity has almost come down to 1.10{sup 5} Bq/to at which level a freely use of the material can be allowed.

  8. Effect of gamma and neutron irradiation on the mechanical properties of Spectralon™ porous PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gourdin, William H., E-mail: gourdin1@llnl.gov [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA USA (United States); Datte, Philip; Jensen, Wayne; Khater, Hesham; Pearson, Mark [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA USA (United States); Girard, Sylvain [Laboratoire Hubert Curien − UMR CNRS 5516, 18 rue du Pr. Benoît Lauras, F-42000 Saint Etienne (France); Paillet, Philippe; Alozy, Eric [CEA, DAM, DIF, F-91297 Arpajon (France)

    2016-11-15

    Highlights: • The effects of neutrons and gammas on PTFE are equivalent for a given absorbed dose. • A neutron fluence of 10{sup 13} n/cm{sup 2} corresponds to a gamma dose of 200 Gy. • The dose-to-fluence conversion factor is approximately 5 × 10{sup 10} n/(cm{sup 2}-Gy). • Irradiation in a low-oxygen environment enhances loads and elongations. • Mechanical properties of PTFE will deteriorate at a neutron fluence of 10{sup 13} n/cm{sup 2}. - Abstract: We establish a correspondence between the mechanical properties (maximum load and failure elongation) of Spectralon™ porous PTFE irradiated with 14 MeV neutrons and 1.17 and 1.33 MeV gammas from a cobalt-60 source. From this correspondence we infer that the effects of neutrons and gammas on this material are approximately equivalent for a given absorbed dose.

  9. Neutron spectrometry and determination of neutron ambient dose equivalents in different LINAC radiotherapy rooms

    International Nuclear Information System (INIS)

    Domingo, C.; Garcia-Fuste, M.J.; Morales, E.; Amgarou, K.; Terron, J.A.; Rosello, J.; Brualla, L.; Nunez, L.; Colmenares, R.; Gomez, F.; Hartmann, G.H.; Sanchez-Doblado, F.; Fernandez, F.

    2010-01-01

    A project has been set up to study the effect on a radiotherapy patient of the neutrons produced around the LINAC accelerator head by photonuclear reactions induced by photons above ∼8 MeV. These neutrons may reach directly the patient, or they may interact with the surrounding materials until they become thermalised, scattering all over the treatment room and affecting the patient as well, contributing to peripheral dose. Spectrometry was performed with a calibrated and validated set of Bonner spheres at a point located at 50 cm from the isocenter, as well as at the place where a digital device for measuring neutrons, based on the upset of SRAM memories induced by thermal neutrons, is located inside the treatment room. Exposures have taken place in six LINAC accelerators with different energies (from 15 to 23 MV) with the aim of relating the spectrometer measurements with the readings of the digital device under various exposure and room geometry conditions. The final purpose of the project is to be able to relate, under any given treatment condition and room geometry, the readings of this digital device to patient neutron effective dose and peripheral dose in organs of interest. This would allow inferring the probability of developing second malignancies as a consequence of the treatment. Results indicate that unit neutron fluence spectra at 50 cm from the isocenter do not depend on accelerator characteristics, while spectra at the place of the digital device are strongly influenced by the treatment room geometry.

  10. Survival of tumor bearing mice by sequencing of low dose rate (LDR) neutron and photon radiation

    International Nuclear Information System (INIS)

    Onomura, C.I.; Feola, J.M.; Maruyama, Y.

    1984-01-01

    Cf-252 neutron radiation (NT) has been shown to be effective therapy for bulky, hypoxic human tumor and to produce consistent rapid clearance and 5 year cures. NT has been found to be more or less effective depending upon the schedule in which it is used and upon mixing with photon radiation. In an effort to study this scheduling and photon effect, LSA tumor was irradiated in vivo in a hypoxic, advanced state, in different schedules in combination of NT with Co-60 photons. The LSA lymphoma of C57BL/ym mice represents an accurate system to assess dose-response of tumor cells in vivo. Mean survival time was used as endpoint. A high RBE for LDR Cf-252 NT was observed with a RBE(n) of -- 5.0. The effect was not greatly sensitive to sequence in which photons were used. Comparison studies were also tested relative to LDR Cs-137 photon radiation. The results support the high efficacy of LDR NT for destruction of hypoxic tumor in vivo

  11. SU-E-T-566: Neutron Dose Cloud Map for Compact ProteusONE Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Patel, B; Syh, J; Rosen, L; Wu, H [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2015-06-15

    Purpose: To establish the base line of neutron cloud during patient treatment in our new compact Proteus One proton pencil beam scanning (PBS) system with various beam delivery gantry angles, with or without range shifter (RS) at different body sites. Pencil beam scanning is an emerging treatment technique, for the concerns of neutron exposure, this study is to evaluate the neutron dose equivalent per given delivered dose under various treatment conditions at our proton therapy center. Methods: A wide energy neutron dose equivalent detector (SWENDI-II, Thermo Scientific, MA) was used for neutron dose measurements. It was conducted in the proton therapy vault during beam was on. The measurement location was specifically marked in order to obtain the equivalent dose of neutron activities (H). The distances of 100, 150 and 200 cm at various locations are from the patient isocenter. The neutron dose was measured of proton energy layers, # of spots, maximal energy range, modulation width, field radius, gantry angle, snout position and delivered dose in CGE. The neutron dose cloud is reproducible and is useful for the future reference. Results: When distance increased the neutron equivalent dose (H) reading did not decrease rapidly with changes of proton energy range, modulation width or spot layers. For cranial cases, the average mSv/CGE was about 0.02 versus 0.032 for pelvis cases. RS will induce higher H to be 0.10 mSv/CGE in average. Conclusion: From this study, neutron per dose ratio (mSv/CGE) slightly depends upon various treatment parameters for pencil beams. For similar treatment conditions, our measurement demonstrates this value for pencil beam scanning beam has lowest than uniform scanning or passive scattering beam with a factor of 5. This factor will be monitored continuously for other upcoming treatment parameters in our facility.

  12. A study of radiation vulnerability of ferroelectric material and devices

    Energy Technology Data Exchange (ETDEWEB)

    Coic, Y M; Musseau, O; Leray, J L [CEA Centre d` Etudes de Bruyeres-le-Chatel, 91 (France)

    1994-12-31

    The radiation effects on ferroelectric material and devices are presented, based on commercially available samples. After recalling the background, effects in ferroelectric PZT capacitors are presented, concerning dose, neutrons and fatigue associated with dose effects. Physical implications and interpretations are sketched. In a second stage, effects are studied at the complete non-volatile RAM device level. Vulnerability in dose, dose rate and neutron fluence of commercial 4 kbit ferroelectric RAM is addressed. 64 kbit results are mentioned in dose rate. These results are compared to previously published data from other manufacturers or laboratories and supplement them. In the appendix, equivalence between rad (Si) and rad (PZT) is discussed in the case of low energy ``10 keV Aracor`` s-rays and {sup 60}Co gamma rays. (author). 24 refs., 11 figs., 7 tabs.

  13. A study of radiation vulnerability of ferroelectric material and devices

    International Nuclear Information System (INIS)

    Coic, Y.M.; Musseau, O.; Leray, J.L.

    1994-01-01

    The radiation effects on ferroelectric material and devices are presented, based on commercially available samples. After recalling the background, effects in ferroelectric PZT capacitors are presented, concerning dose, neutrons and fatigue associated with dose effects. Physical implications and interpretations are sketched. In a second stage, effects are studied at the complete non-volatile RAM device level. Vulnerability in dose, dose rate and neutron fluence of commercial 4 kbit ferroelectric RAM is addressed. 64 kbit results are mentioned in dose rate. These results are compared to previously published data from other manufacturers or laboratories and supplement them. In the appendix, equivalence between rad (Si) and rad (PZT) is discussed in the case of low energy ''10 keV Aracor'' s-rays and 60 Co gamma rays. (author). 24 refs., 11 figs., 7 tabs

  14. Radiation doses to Finns

    International Nuclear Information System (INIS)

    Rantalainen, L.

    1996-01-01

    The estimated annual radiation doses to Finns have been reduced in the recent years without any change in the actual radiation environment. This is because the radiation types have been changed. The risk factors will probably be changed again in the future, because recent studies show discrepancies in the neutron dosimetry concerning the city of Hiroshima. Neutron dosimetry discrepancy has been found between the predicted and estimated neutron radiation. The prediction of neutron radiation is calculated by Monte Carlo simulations, which have also been used when designing recommendations for the limits of radiation doses (ICRP60). Estimation of the neutron radiation is made on the basis of measured neutron activation of materials in the city. The estimated neutron dose beyond 1 km is two to ten, or more, times as high as the predicted dose. This discrepancy is important, because the most relevant distances with respect to radiation risk evaluation are between 1 and 2 km. Because of this discrepancy, the present radiation risk factors for gamma and neutron radiation, which rely on the Monte Carlo calculations, are false, too. The recommendations of ICRP60 have been adopted in a few countries, including Finland, and they affect the planned common limits of the EU. It is questionable whether happiness is increased by adopting false limits, even if they are common. (orig.) (2 figs., 1 tab.)

  15. ENERGY RESPONSE OF FLUORESCENT NUCLEAR TRACK DETECTORS OF VARIOUS COLORATIONS TO MONOENERGETIC NEUTRONS.

    Science.gov (United States)

    Fomenko, V; Moreno, B; Million, M; Harrison, J; Akselrod, M

    2017-10-25

    The neutron-energy dependence of the track-counting sensitivity of fluorescent nuclear track detectors (FNTDs) at two ranges of Mg doping, resulting in different crystal colorations, was investigated. The performance of FNTDs was studied with the following converters: Li-glass for thermal to intermediate-energy neutrons, polyethylene for fast neutrons, and polytetrafluoroethylene (Teflon™) for photon- and radon-background subtraction. The irradiations with monoenergetic neutrons were performed at the National Physics Laboratory (NPL), UK. The energy range was varied from 144 keV to 16.5 MeV in the personal dose equivalent range from 1 to 3 mSv. Monte Carlo simulations were performed to model the response of FNTDs to monoenergetic neutrons. A good agreement with the experimental data was observed suggesting the development of a basic model for future MC studies. Further work will focus on increasing FNTD sensitivity to low-energy neutrons and developing a faster imaging technique for scanning larger areas to improve counting statistics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Prediction of in-phantom dose distribution using in-air neutron beam characteristics for BNCS

    International Nuclear Information System (INIS)

    Verbeke, Jerome M.

    1999-01-01

    A monoenergetic neutron beam simulation study is carried out to determine the optimal neutron energy range for treatment of rheumatoid arthritis using radiation synovectomy. The goal of the treatment is the ablation of diseased synovial membranes in joints, such as knees and fingers. This study focuses on human knee joints. Two figures-of-merit are used to measure the neutron beam quality, the ratio of the synovium absorbed dose to the skin absorbed dose, and the ratio of the synovium absorbed dose to the bone absorbed dose. It was found that (a) thermal neutron beams are optimal for treatment, (b) similar absorbed dose rates and therapeutic ratios are obtained with monodirectional and isotropic neutron beams. Computation of the dose distribution in a human knee requires the simulation of particle transport from the neutron source to the knee phantom through the moderator. A method was developed to predict the dose distribution in a knee phantom from any neutron and photon beam spectra incident on the knee. This method was revealed to be reasonably accurate and enabled one to reduce by a factor of 10 the particle transport simulation time by modeling the moderator only

  17. Prediction of in-phantom dose distribution using in-air neutron beam characteristics for BNCS

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, Jerome M.

    1999-12-14

    A monoenergetic neutron beam simulation study is carried out to determine the optimal neutron energy range for treatment of rheumatoid arthritis using radiation synovectomy. The goal of the treatment is the ablation of diseased synovial membranes in joints, such as knees and fingers. This study focuses on human knee joints. Two figures-of-merit are used to measure the neutron beam quality, the ratio of the synovium absorbed dose to the skin absorbed dose, and the ratio of the synovium absorbed dose to the bone absorbed dose. It was found that (a) thermal neutron beams are optimal for treatment, (b) similar absorbed dose rates and therapeutic ratios are obtained with monodirectional and isotropic neutron beams. Computation of the dose distribution in a human knee requires the simulation of particle transport from the neutron source to the knee phantom through the moderator. A method was developed to predict the dose distribution in a knee phantom from any neutron and photon beam spectra incident on the knee. This method was revealed to be reasonably accurate and enabled one to reduce by a factor of 10 the particle transport simulation time by modeling the moderator only.

  18. Neutron capture in the 1.15-keV resonance of /sup 56/Fe using Moxon-Rae detectors

    International Nuclear Information System (INIS)

    Corvi, F.; Bastian, C.; Wisshak, K.

    1986-01-01

    The capture area in the 1.15-keV neutron resonance of /sup 56/Fe was measured with Moxon-Rae detectors with converters of bismuth, bismuth-graphite, and graphite. The data were normalized to gold capture at 4.91 eV using the saturated resonance method. Two separate measurements were performed: the first with the detector axis at 120 deg with respect to the neutron beam direction and the second with the axis at 90 deg. The average of the results over the three detectors is gΓ/sub n/Γγ/sub / Γ=(64.9 + .2.4) MeV for the 120-deg run and gΓn/Γγ/Γ=(63.5 + .2.1) MeV for the 90-deg run. These values are 14 to 16% larger than the corresponding one from transmission data. No reason is found for such a discrepancy

  19. Angular distributions of projectiles following electron capture from C60 by 2.5-keV Ar8+

    International Nuclear Information System (INIS)

    Walch, B.; Thumm, U.; Stoeckli, M.; Cocke, C.L.; Klawikowski, S.

    1998-01-01

    Experimental measurements of the projectile angular distributions for 2.5-keV Ar 8+ ions capturing one to five electrons from a gas-phase C 60 target are presented. The number of captured electrons was determined by demanding a coincidence between the scattered projectile and a charge-state-analyzed intact C 60 recoil ion. The results are compared to calculations based on a dynamical classical overbarrier model. Good agreement is obtained only if the influence on the projectile trajectory by the large polarizability of the C 60 target is taken into account, thereby making the collective dielectric response of the cluster target observable in a scattering experiment. copyright 1998 The American Physical Society

  20. Boron neutron capture therapy using mixed epithermal and thermal neutron beams in patients with malignant glioma-correlation between radiation dose and radiation injury and clinical outcome

    International Nuclear Information System (INIS)

    Kageji, Teruyoshi; Nagahiro, Shinji; Matsuzaki, Kazuhito; Mizobuchi, Yoshifumi; Toi, Hiroyuki; Nakagawa, Yoshinobu; Kumada, Hiroaki

    2006-01-01

    Purpose: To clarify the correlation between the radiation dose and clinical outcome of sodium borocaptate-based intraoperative boron neutron capture therapy in patients with malignant glioma. Methods and Materials: The first protocol (P1998, n = 8) prescribed a maximal gross tumor volume (GTV) dose of 15 Gy. In 2001, a dose-escalated protocol was introduced (P2001, n 11), which prescribed a maximal vascular volume dose of 15 Gy or, alternatively, a clinical target volume (CTV) dose of 18 Gy. Results: The GTV and CTV doses in P2001 were 1.1-1.3 times greater than those in P1998. The maximal vascular volume dose of those with acute radiation injury was 15.8 Gy. The mean GTV and CTV dose in long-term survivors with glioblastoma was 26.4 and 16.5 Gy, respectively. A statistically significant correlation between the GTV dose and median survival time was found. In the 11 glioblastoma patients in P2001, the median survival time was 19.5 months and 1- and 2-year survival rate was 60.6% and 37.9%, respectively. Conclusion: Dose escalation contributed to the improvement in clinical outcome. To avoid radiation injury, the maximal vascular volume dose should be <12 Gy. For long-term survival in patients with glioblastoma after boron neutron capture therapy, the optimal mean dose of the GTV and CTV was 26 and 16 Gy, respectively

  1. Dose Calibration of the ISS-RAD Fast Neutron Detector

    Science.gov (United States)

    Zeitlin, C.

    2015-01-01

    The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of ?10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

  2. A study of molecular correlations observed in the small-angle photon scattering distributions of 60 KeV photons interacting with low-atomic-number media

    International Nuclear Information System (INIS)

    Bradley, D.A.

    1988-01-01

    A variant of the multisection filter and annular target geometry, with a designed angular acceptance of +-0.5 0 , has been utilised in measuring accurate, O(5%), absolute total differential scattering cross sections of 60 KeV photons for H 2 O, methyl methacrylate (C 5 H 8 O 2 ) n and nylon-6 (C 12 H 22 O 3 N 2 ) n in the angular scattering range of 2 0 -10 0 . The effects of molecular correlations manifest, to varying degree, in strong forward peaking of the scattered photon distribution. Comparison is made with available experiment and theory [pt

  3. Tissue responses to low protracted doses of high LET radiations or photons: Early and late damage relevant to radio-protective countermeasures

    Science.gov (United States)

    Ainsworth, E. J.; Afzal, S. M. J.; Crouse, D. A.; Hanson, W. R.; Fry, R. J. M.

    Early and late murine tissue responses to single or fractionated low doses of heavy charged particles, fission-spectrum neutrons or gamma rays are considered. Damage to the hematopoietic system is emphasized, but results on acute lethality, host response to challenge with transplanted leukemia cells and life-shortening are presented. Low dose rates per fraction were used in some neutron experiments. Split-dose lethality studies (LD 50/30) with fission neutrons indicated greater accumulation of injury during a 9 fraction course (over 17 days) than was the case for γ-radiation. When total doses of 96 or 247 cGy of neutrons or γ rays were given as a single dose or in 9 fractions, a significant sparing effect on femur CFU-S depression was observed for both radiation qualities during the first 11 days, but there was not an earlier return to normal with dose fractionation. During the 9 fraction sequence, a significant sparing effect of low dose rate on CFU-S depression was observed in both neutron and γ-irradiated mice. CFU-S content at the end of the fractionation sequence did not correlate with measured LD 50/30. Sustained depression of femur and spleen CFU-S and a significant thrombocytopenia were observed when a total neutron dose of 240 cGy was given in 72 fractions over 24 weeks at low dose rates. The temporal aspects of CFU-S repopulation were different after a single versus fractionated neutron doses. The sustained reduction in the size of the CFU-S population was accompanied by an increase in the fraction in DNA synthesis. The proliferation characteristics and effects of age were different for radial CFU-S population closely associated with bone, compared with the axial population that can be readily aspirated from the femur. In aged irradiated animals, the CFU-S proliferation/redistribution response to typhoid vaccine showed both an age and radiation effect. After high single doses of neutrons or γ rays, a significant age- and radiation-related deficiency

  4. The Comparison Study of Neutron Activation Analysis and Fission Track Technique for Uranium Determination

    International Nuclear Information System (INIS)

    Sirinuntavid, Alice; Rodthongkom, Chouvana

    2007-08-01

    Full text: Comparison between Neutron Activation Analysis (NAA) and fission track technique for uranium determination in solid samples was studied by use of standard reference materials, i.e., ore, coal fly ash, soil. For NAA, the epithermal neutron was applied for activated irradiation. Then, the 74.5 keV gamma from U-239 or 277.7 keV gamma from Np-239 was measured. For high Uranium content samples, NAA method with 74.5 keV gamma measurement, gave higher precision result than the 277.7 keV gamma measurement method. NAA method with 277.7 keV gamma measurement, gave higher sensitivity and precision result for low Uranium content samples and the uranium contained less than 10 ppm samples. Nevertheless, the latter procedure needed longer time for neutron irradiation and analysis procedure. In comparison the results of Uranium analysis between NAA and fission track, it was found that no significant difference within 95 % of confidence level

  5. Improving neutron dosimetry using bubble detector technology

    International Nuclear Information System (INIS)

    Buckner, M.A.

    1993-02-01

    Providing accurate neutron dosimetry for a variety of neutron energy spectra is a formidable task for any dosimetry system. Unless something is known about the neutron spectrum prior to processing the dosimeter, the calculated dose may vary greatly from that actually encountered; that is until now. The entrance of bubble detector technology into the field of neutron dosimetry has eliminated the necessity of having an a priori knowledge of the neutron energy spectra. Recently, a new approach in measuring personnel neutron dose equivalent was developed at Oak Ridge National Laboratory. By using bubble detectors in combination with current thermoluminescent dosimeters (TLDs) as a Combination Personnel Neutron Dosimeter (CPND), not only is it possible to provide accurate dose equivalent results, but a simple four-interval neutron energy spectrum is obtained as well. The components of the CPND are a Harshaw albedo TLD and two bubble detectors with theoretical energy thresholds of 100 key and 1500 keV. Presented are (1) a synoptic history surrounding emergence of bubble detector technology, (2) a brief overview of the current theory on mechanisms of interaction, (3) the data and analysis process involved in refining the response functions, (4) performance evaluation of the original CPND and a reevaluation of the same data under the modified method, (5) the procedure used to determine the reference values of component fluence and dose equivalent for field assessment, (6) analysis of the after-modification results, (7) a critique of some currently held assumptions, offering some alternative explanations, and (8) thoughts concerning potential applications and directions for future research

  6. Neutron Measurements At Hanford's Plutonium Finishing Plant

    International Nuclear Information System (INIS)

    Conrady, Matthew M.; Berg, Randal K.; Scherpelz, Robert I.; Rathbone, Bruce A.

    2009-01-01

    The Pacific Northwest National Laboratory (PNNL) conducted neutron measurements at Hanford's Plutonium Finishing Plant (PFP). The measurements were performed to evaluate the performance of the Hanford Standard Dosimeter (HSD) and the 8816 TLD component of the Hanford Combination Neutron Dosimeter (HCND) in the neutron fields responsible for worker neutron exposures. For this study, TEPC detectors and multisphere spectrometers were used to measure neutron dose equivalent rate, and multispheres were used to measure average neutron energy. Water-filled phantoms holding Hanford dosimeters were positioned at each measurement location. The phantoms were positioned in the same location where a multisphere measurement was taken and TEPCs were also positioned there. Plant survey meters were also used to measure neutron dose rates at all locations. Three measurement locations were chose near the HC-9B glovebox in room 228A of Building 234-5. The multisphere spectrometers measured average neutron energies in the range of 337 to 555 keV at these locations. Personal dose equivalent, Hp(10)n, as measured by the multisphere and TEPC, ranged from 2.7 to 9.7 mrem/h in the three locations. Effective dose assuming a rotational geometry (EROT) was substantially lower than Hp(10), ranging from 1.3 to 3.6 mrem/h. These values were lower than the reported values from dosimeters exposed on a rotating phantom. Effective dose assuming an AP geometry (EAP) was also substantially lower than Hp(10), ranging from 2.3 to 6.5 mrem/h. These values were lower than the reported values from the dosimeters on slab phantoms. Since the effective dose values were lower than reported values from dosimeters, the dosimeters were shown to be conservative estimates of the protection quantities.

  7. Measurement of the 238U subthreshold fission cross section for incident neutron energies between 0.6 and 100 keV

    International Nuclear Information System (INIS)

    Difilippo, F.C.; Perez, R.B.; de Saussure, G.; Olsen, D.K.; Ingle, R.W.

    1977-01-01

    The neutron-induced 238 U subthreshold fission cross section has been measured in the neutron energy range between 0.6 and 100 keV. A total of 28 fission clusters were identified. The well-known clusters at 721 and 1210 eV appeared resolved into their Class I components. Average 238 U subthreshold fission cross sections were determined and compared with available results in the literature. The measurement is interpreted in terms of fission doorway (Class II levels) arising from the assumption of the existence of a double-humped fission barrier for the ( 238 U + n) compound nucleus at large deformations. On the basis of this model, several fission barrier parameters were determined

  8. Occupational dose due to neutrons in medical linear accelerators

    International Nuclear Information System (INIS)

    Larcher, Ana M.; Bonet Duran, Stella M.; Lerner, Ana M.

    2000-01-01

    This paper describes a semi-empirical method to calculate the occupational dose due to neutrons and capture gamma rays in medical linear accelerators. It compares theoretical dose values with measurements performed in several 15 MeV medical accelerators installed in the country. Good agreement has been found between calculations made using the model and dose measurements, except for those accelerator rooms in which the maze length was shorter than the postulated tenth value distance. For those cases the model seems to overestimate neutron dose. The results demonstrate that the semi-empirical model is a good tool for quick and conservative shielding calculations for radiation protection purposes. Nevertheless, it is necessary to continue with the measurements in order to perform a more accurate validation of the model. (author)

  9. Absorbed dose conversion coefficients for embryo and foetus in neutron fields

    International Nuclear Information System (INIS)

    Chen, J.

    2007-01-01

    The Monte Carlo code MCNPX has been used to determine mean absorbed doses to the embryo and foetus when the mother is exposed to neutron fields. There are situations, such as on-board aircraft, where high-energy neutrons are often peaked in top down (TOP) direction. In addition to previous publications for standard irradiation geometries, this study provides absorbed dose conversion coefficients for the embryo of 8 weeks and the foetus of 3, 6 or 9 months at TOP irradiation geometry. The conversion coefficients are compared with the coefficients in isotropic irradiation (ISO). With increasing neutron energies, the conversion coefficients in TOP irradiation become dominant. A set of conversion coefficients is constructed from the higher value in either ISO or TOP irradiation at a given neutron energy. In cases where the irradiation geometry is not adequately known, this set of conversion coefficients can be used in a conservative dose assessment for embryo and foetus in neutron fields. (authors)

  10. Energy dependence of the air kerma response of a liquid ionization chamber at photon energies between 8 keV and 1250 keV

    International Nuclear Information System (INIS)

    Hilgers, G.; Bahar-Gogani, J.; Wickman, G.

    2002-01-01

    Full text: In its recent reports on cardiovascular brachytherapy the DGMP recommends the source strength of brachytherapy sources being characterized in terms of absorbed dose to water at a distance of 2 mm from the central axis of the source. As a consequence, the response of a detector suitable for characterizing such sources with respect to absorbed dose to water should depend only to a small extent on radiation energy. Additionally, the detection volume of the detector has to be sufficiently small for the necessary spatial resolution to be obtained. The liquid ionization chamber as described in seems to be a promising means for this type of measurements. The two components of the ionization liquid (TMS and isooctane) can be mixed in a ratio which ensures that the mass-energy absorption coefficient of the resulting mixture deviates from that of water by less than ±15 % down to photon energies of 10 keV. Due to the high density of the ionization medium, the spacing between the two electrodes of the ionization chamber can be made as small as a few tenths of a millimeter and still the resulting ionization current is sufficiently large. The ionization chamber used in the present investigation is a plane parallel chamber 5 mm in diameter and of 0.3 mm electrode spacing. The ionization medium is a mixture of 40 % TMS and 60 % isooctane. The irradiations were carried out with the ISO wide spectra series with tube voltages between 10 kV and 300 kV and with 137 Cs and 60 Co γ-radiation. As a first step, the response of the liquid ionization chamber was investigated with respect to air kerma instead of absorbed dose to water. Although the mass-energy absorption coefficient of the liquid deviates from that of air by less than ±10 % over the photon energy range, the measured chamber response varies by a factor of about 3.5. Monte Carlo calculations carried out with EGSnrc show a variation of the chamber response smaller than ±20 %. Measurements of the ion yield of the

  11. Neutron time behavior for deuterium neutral beam injection into a hydrogen plasma in ORMAK

    International Nuclear Information System (INIS)

    England, A.C.; Howe, H.C.; Mihalczo, J.T.; Fowler, R.H.

    1977-10-01

    Neutrons were produced by D-D interactions when a 28-keV deuterium beam was coinjected into a hydrogen plasma in the Oak Ridge Tokamak (ORMAK). Fokker-Planck calculations, which correctly predict the time behavior of the neutron rate after beam turnon, show that the majority of the neutrons are from injected particles interacting with previously injected deuterons that have scattered to pitch angles of approximately 60 to 90 0 while slowing down

  12. Effect of low level Doses of fast neutrons on the toxicity of snake venom through measuring some biophysical properties of blood serum of rats

    International Nuclear Information System (INIS)

    Hanafy, M.S.; Metwali, R.

    2001-01-01

    This study was conducted to investigate the effect of low level doses of fission neutrons from Cf 252 source on sublethal doses (low medium) of snake venom cerastes cerastes by injecting albino eats with unirradiated or irradiated venom and measuring the biophysical alterations in the blood serum of the rats. The biophysical properties of the total serum proteins were studied through measuring their dielectric relaxation and the electric conductivity in the frequency range 0.1→5 MHz at 4 degree C. The absorption spectra of the extracted total serum protein were also measured. The results indicated that there are pronounced changes in the molecular constructions of the total serum protein such as the molecular radii, shape, the relaxation time and dielectric increment for the rats injected with unirradiated venom but for the rats injected with irradiated venom (3x10 8 n/cm 2 ) corresponding values approach the control value. These changes in the molecular constructions of the total serum protein indicate changes in its biochemical properties. This fact was revealed in a previous work, where the irradiation with the fast neutrons were found to decrease the toxicity of the venom

  13. Photon and neutron doses of the personnel using moisture and density measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V. [Greek Atomic Energy Commission, Agia Paraskevi, Attiki, 60092 (Greece)

    2006-07-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a {sup 137}Cs source for density measurements and an {sup 241}Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  14. Photon and neutron doses of the personnel using moisture and density measurement devices

    International Nuclear Information System (INIS)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V.

    2006-01-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a 137 Cs source for density measurements and an 241 Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  15. Effects of secondary interactions on the dose calculation in treatments with Boron Neutron Capture Therapy (BNCT)

    International Nuclear Information System (INIS)

    Monteiro, E.

    2004-01-01

    The aimed of this work consists of evaluating the influence of the secondary contributions of dose (thermal neutrons dose, epithermal neutrons dose, fast neutrons dose and photon dose) in treatment planning with BNCT. MCNP4B Code was used to calculate RBE-Gy doses through the irradiation of the modified Snyder head head phantom.A reduction of the therapeutical gain of monoenergetic neutron beans was observed in non invasive treatments, provoked for the predominance of the fast neutron dose component in the skin, showing that the secondary contributions of dose can contribute more in the direction to raise the dose in the fabric healthy that in the tumor, thus reducing the treatment efficiency. (author)

  16. The importance of $^{22}$Ne($\\alpha$, n)$^{25}$Mg as s-process neutron source and the s-process thermometer $^{151}$Sm

    CERN Multimedia

    Leal, L C; Kitis, G; Guber, K H; Cox, J; Quaranta, A; Koehler, P E

    2002-01-01

    Neutron capture nucleosynthesis provides a sensitive tool for testing He burning scenarios in massive stars as well as in low mass AGB stars. During this phase of stellar evolution nuclei in the mass region between Fe and Bi are producted by the slow neutron capture process ($\\emph{s}$-process). Because of the relatively low neutron densities, neutron capture times are long compared to typical $\\beta$-half-lives. This implies that the reaction path follows the stability valley and that the resulting abundances are essentially determined by the respective neutron capture cross sections. Hence, these data represent the most important nuclear physics input for $\\emph{s}$-process studies. In general, laboratory measurements are required in the energy range 0.1 < E$_{n}$ < 300 keV in order to obtain reliable averages over the stellar Maxwell-Boltzmann distribution for thermal energies between kT=5 keV and 30 keV. The extremely high neutron flux, the energy resolution and the excellent duty factor make the nT...

  17. Measurement of the 232Th capture cross section in the energy region 5 keV-150 keV

    International Nuclear Information System (INIS)

    Lobo, G.; Schillebeeckx, P.; Brusegan, A.; Borella, A.; Corvi, F.; Janeva, N.; Volev, K.

    2003-01-01

    The 232 Th(n,γ) neutron capture cross-section is of great importance for accelerator driven reactor (ADS) systems based on the Thorium-Uranium fuel cycle. An analysis of the required nuclear data, reveals that the status of the 232 Th capture data is far from the requested 2 % uncertainty level. Recently 232 Th average capture measurements, between 5-200 keV neutron energy, were performed at the FzK Karlsruhe (DE). A comparison of the measured averaged capture cross section with the evaluated data files shows a reasonable agreement in the neutron energy range above 15 keV. However, discrepancies of up to 40 % at lower neutron energies are observed. The same order of discrepancies is observed when comparing their results with the results obtained by Macklin et al. at ORELA. To clarify these discrepancies we measured at IRMM the average capture cross-section at the GEel LINear Accelerator (GELINA). The measurements were performed at a 14.37 m flight-path using the Time-Of-Flight (TOF) method. The gamma rays, originating from the 232 Th(n,γ) reaction, were detected by a pair of C 6 D 6 -based liquid scintillators applying a pulse-height weighting method. The neutron flux was measured with an ionisation chamber placed at 80 cm before the Thorium sample. This chamber has a cathode loaded with two back-to-back layers of about 40 μg/cm 2 10 B. The sample consisted of a metallic natural thorium disc of 8 cm diameter and 0.5 mm thick, corresponding to a thickness of 1.588 10 -3 at/b. The background for the capture measurements consists of a time independent and time dependent component. The former, mainly produced by the radioactive decay of the sample, was deduced from measurements with a closed beam. The latter was measured by replacing the thorium sample with a 0.5 mm thick 208 Pb sample of the same size. Such a Pb sample has practically the same scattering probability as the thorium sample and has a negligible capture yield. Therefore, the 208 Pb run provides a good

  18. Diagnostics and equipment for ion temperatures and implosion neutron yields

    International Nuclear Information System (INIS)

    Chen Jiabin; Zheng Zhijian; Peng Hansheng; Wen Shuhuai; Zhang Baohan; Ding Yongkun; Qi Lanying; Chen Ming; Li Chaoguang

    2001-01-01

    Fuel ion temperature is of great importance in the ICF research field. A set of ultra-fast quenched plastic scintillation detector system was fabricated for low yield neutron diagnostic. The detection efficiency and the sensitivity to DT neutrons were scaled using a K-400 accelerator and a pulse neutron tube from Russia with a width 5 - 10 ns, respectively. Its time response functions were calibrated by cosmic ray and implosion neutron separately. Under the conditions of low laser energy so low neutron yield and very limited space, fuel ion temperatures (including implosion neutron yields at the same time) were obtained. The measured ion temperatures for exploding pusher capsules were between 4 keV and 5 keV with errors +-(15 - 25)%. The neutron yields were 5 x 10 8 - 3 x 10 9 for exploding pusher capsules and 1.6 x 10 7 - 3.9 x 10 8 for ablation ones with errors +- (7 - 10)%. Of the six shots of neutron yields calculated, five are in good agreement with authors' experimental results in the range of +- 20%. Not only the heat-conducting mechanism and the effects on implosion of the energy balance of each path of incidence laser, target design, fuel mixture as well as hot electron behavior have been investigated, but also the upgrade level of the laser facility Shengguang II has been tested

  19. Assessment of doses due to secondary neutrons received by patient treated by proton therapy

    International Nuclear Information System (INIS)

    Sayah, R.; Martinetti, F.; Donadille, L.; Clairand, I.; Delacroix, S.; De Oliveira, A.; Herault, J.

    2010-01-01

    Proton therapy is a specific technique of radiotherapy which aims at destroying cancerous cells by irradiating them with a proton beam. Nuclear reactions in the device and in the patient himself induce secondary radiations involving mainly neutrons which contribute to an additional dose for the patient. The author reports a study aimed at the assessment of these doses due to secondary neutrons in the case of ophthalmological and intra-cranial treatments. He presents a Monte Carlo simulation of the room and of the apparatus, reports the experimental validation of the model (dose deposited by protons in a water phantom, ambient dose equivalent due to neutrons in the treatment room, absorbed dose due to secondary particles in an anthropomorphic phantom), and the assessment with a mathematical phantom of doses dues to secondary neutrons received by organs during an ophthalmological treatment. He finally evokes current works of calculation of doses due to secondary neutrons in the case of intra-cranial treatments

  20. Measurement of the neutron and gamma-ray spectra originating from a 14-MeV neutron source in liquid nitrogen and liquid air

    International Nuclear Information System (INIS)

    Broecker, B.; Clausen, K.; Schneider-Kuehnle, P.; Weinert, M.

    1975-01-01

    An experiment to measure the radiation transport originating from a 14-MeV neutron source in liquid nitrogen and liquid air is presented. Neutron and gamma-ray spectra were measured with a proton-recoil NE 213 scintillator and with four spherical proportional counters in a tank filled with liquid nitrogen or liquid air. The neutron spectra cover the energy range of 20 keV to 18 MeV. The source-detector separation varies in the liquid medium between 60 and 240 cm. The experimental setup is briefly described and the errors are estimated. (2 tables, 9 figures) (auth)

  1. Destruction of C60 films by boron ion bombardment

    International Nuclear Information System (INIS)

    Ren Zhongmin; Du Yuancheng; Ying Zhifeng; Xiong Xiaxing; Li Fuming

    1995-01-01

    C 60 films are bombarded by 100 keV boron ion beams at doses ranging from 3x10 14 to 1x10 16 /cm 2 . The bombarded films are analyzed using Fourier transform infrared spectroscopy (FTIR), Raman spectra and X-ray diffraction (XRD) measurements. Most C 60 soccer-balls in the implanted region in the films are found to be broken at a dose over 1x10 15 /cm 2 , while at a dose less than 6x10 14 /cm 2 a few C 60 molecules remain undestroyed and maintain some crystal structure. The results of the analyses suggest a complete disintegration of a C 60 molecule under B + bombardment. ((orig.))

  2. Activation measurements for thermal neutrons. Part A. Cobalt (60Co) activation

    International Nuclear Information System (INIS)

    Kerr, George D.; Shizuma, Kiyoshi; Endo, Satoru; Maruyama, Takashi; Cullings, Harry M.; Komura, Kazuhisa; Okumura, Yutaka; Egbert, Stephen D.

    2005-01-01

    The 60 Co measurements at Hiroshima and Nagasaki were reviewed and compared with the results of the new DS02 calculations for the two cities. Some corrections were made to previously published data from the 1965 measurements of JNIRS, ground ranges of all of the 60 Co measurements were reviewed and new ground ranges were determined when possible by transforming sample coordinates to the new city maps for Hiroshima and Nagasaki, and transmission factors were investigated for a number of samples used in the 60 Co measurements. Transmission factors were not calculated for all samples used in the 60 Co measurements but some general rules were given for estimating transmission factors for these samples. Experimental measurements of the background 60 Co activity from environmental neutrons were also reviewed, and it was found that the 60 Co background from environmental neutrons was not an important factor in the 60 Co measurements of bomb-induced activity at either city. (J.P.N.)

  3. Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

    International Nuclear Information System (INIS)

    Ishii, K.; Okamoto, A.; Kitajima, S.; Sasao, M.; Shinohara, K.; Ishikawa, M.; Baba, M.; Isobe, M.

    2010-01-01

    A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-γ pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and γ-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the γ-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

  4. Tissue responses to low protracted doses of high let radiations or photons: Early and late damage relevant to radio-protective countermeasures

    International Nuclear Information System (INIS)

    Ainsworth, E.J.; Afzal, S.M.J.; Crouse, D.A.; Hanson, W.R.; Fry, R.J.M.

    1988-01-01

    Early and late murine tissue responses to single or fractionated low doses of heavy charged particles, fission-spectrum neutrons or gamma rays are considered. Damage to the hematopoietic system is emphasized, but results on acute lethality, host response to challenge with transplanted leukemia cells and life-shortening are presented. Low dose rates per fraction were used in some neutron experiments. Split-dose lethality studies (LD 50/30) with fission neutrons indicated greater accumulation of injury during a 9 fraction course (over 17 days) than was the case for γ-radiation. When total doses of 96 or 247 cGy of neutrons or γ rays were given as a single dose or in 9 fractions, a significant sparing effect on femur CFU-S depression was observed for both radiation qualities during the first 11 days, but there was not an earlier return to normal with dose fractionation. During the 9 fraction sequence, a significant sparing effect of low dose rate on CFU-S depression was observed in both neutron and γ-irradiated mice. CFU-S content at the end of the fractionation sequence did not correlate with measured LD 50/30. Sustained depression of femur and spleen CFU-S and a significant thrombocytopenia were observed when a total neutron dose of 240 cGy was given in 72 fractions over 24 weeks at low dose rates. The temporal aspects of CFU-S repopulation were different after a single versus fractionated neutron doses. The sustained reduction in the size of the CFU-S population was accompanied by an increase in the fraction in DNA synthesis. The proliferation characteristics and effects of age were different for radial CFU-S population closely associated with bone, compared with the axial population that can be readily aspirated from the femur. In aged irradiated animals, the CFU-S proliferation/redistribution response to typhoid vaccine showed both an age and radiation effect. 63 refs., 6 figs., 7 tabs

  5. Utilization of a pulsed D-T neutron generator

    International Nuclear Information System (INIS)

    Vilaithong, T.; Singkarat, S.; Tippawan, U.

    2000-01-01

    In the past two decades the IAEA has supported the establishment of neutron laboratories in many developing countries by providing small D-T neutron generators. The neutron generator is basically a low energy (100-400 keV) ion accelerator capable of producing a continuous beam of deuterons with a current in the range between 1-2.5 mA. These neutron generators are primarily intended to be used for fast neutron activation analysis. This paper describes the utilization of a 14 MeV neutron generator in continuous and pulsed beam modes in applied neutron physics program at Chiang Mai University. (author)

  6. Beta-delayed neutron decay of $^{33}$Na

    CERN Document Server

    Radivojevic, Z; Caurier, E; Cederkäll, J; Courtin, S; Dessagne, P; Jokinen, A; Knipper, A; Le Scornet, G; Lyapin, V G; Miehé, C; Nowacki, F; Nummela, S; Oinonen, M; Poirier, E; Ramdhane, M; Trzaska, W H; Walter, G; Äystö, J

    2002-01-01

    Beta-delayed neutron decay of /sup 33/Na has been studied using the on-line mass separator ISOLDE. The delayed neutron spectra were measured by time-of-flight technique using fast scintillators. Two main neutron groups at 800(60) and 1020(80) keV were assigned to the /sup 33/Na decay, showing evidence for strong feeding of states at about 4 MeV in /sup 33/Mg. By simultaneous beta - gamma -n counting the delayed neutron emission probabilities P/sub 1n/ = 47(6)% and P /sub 2n/ = 13(3)% were determined. The half-life value for /sup 33 /Na, T/sub 1/2/ = 8.0(3) ms, was measured by three different techniques, one employing identifying gamma transitions and two employing beta and neutron counting. (21 refs).

  7. Testing a newly developed single-sphere neutron spectrometer in reference monochromatic fields from 147 keV to 14.8 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN—LNF Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); Gómez-Ros, J.M. [INFN—LNF Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Pola, A.; Introini, M.V. [Politecnico di Milano - Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano (Italy); Bortot, D. [INFN—LNF Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); Politecnico di Milano - Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano (Italy); Gentile, A.; Esposito, A.; Mazzitelli, G.; Buonomo, B.; Quintieri, L.; Foggetta, L. [INFN—LNF Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy)

    2013-06-21

    A new neutron spectrometer, designed to simultaneously respond from the thermal domain up to hundreds of MeV neutrons, was designed and built in the framework of the INFN project NESCOFI@BTF. It has been called SP{sup 2} (SPherical SPectrometer) and it consists of 31 thermal neutron detectors embedded in a 25 cm diameter polyethylene sphere with an internal 1 cm thick lead shell. The new spectrometer shows similar performance as the Bonner sphere spectrometer, but has the notable advantage of requiring only one exposure to determine the whole spectrum. The SP{sup 2} response matrix, previously calculated with MCNP, has been experimentally evaluated with monochromatic reference neutron fields from 147 keV to 14.8 MeV at PTB Braunschweig. As suitable thermal neutron detectors, Dysprosium activation foils were adopted at this stage. The results of the experiment confirmed the correctness of the response matrix within an overall uncertainty of ±3%. The next phase of the NESCOFI@BTF project will be the replacement of passive detectors with active counters, thus leading to a real-time spectrometric monitor that is expected to significantly innovate the neutron control task in neutron-producing facilities, such as the beam-lines for industrial irradiation or condensed matter studies.

  8. Neutron dose equivalent next to the target shield of a neutron therapy facility using an LET counter

    International Nuclear Information System (INIS)

    Stinchcomb, T.G.; Kuchnir, F.T.

    1981-01-01

    The use of a spherical tissue-equivalent proportional counter for measurements of the lineal energy (y) and derivations of the linear energy transfer (LET) for fast neutrons has the advantage of giving distributions of dose and dose equivalent as functions of either LET or y. A measurement next to the target shielding of the neutron therapy facility at the University of Chicago Hospitals and Clinics (UCHC) is described, and the data processing is outlined. The distributions are presented and compared to those from measurements in the neutron beam. The average quality factors are presented

  9. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  10. Spectral correction factors for conventional neutron dose meters used in high-energy neutron environments improved and extended results based on a complete survey of all neutron spectra in IAEA-TRS-403

    International Nuclear Information System (INIS)

    Oparaji, U.; Tsai, Y. H.; Liu, Y. C.; Lee, K. W.; Patelli, E.; Sheu, R. J.

    2017-01-01

    This paper presents improved and extended results of our previous study on corrections for conventional neutron dose meters used in environments with high-energy neutrons (E n > 10 MeV). Conventional moderated-type neutron dose meters tend to underestimate the dose contribution of high-energy neutrons because of the opposite trends of dose conversion coefficients and detection efficiencies as the neutron energy increases. A practical correction scheme was proposed based on analysis of hundreds of neutron spectra in the IAEA-TRS-403 report. By comparing 252 Cf-calibrated dose responses with reference values derived from fluence-to-dose conversion coefficients, this study provides recommendations for neutron field characterization and the corresponding dose correction factors. Further sensitivity studies confirm the appropriateness of the proposed scheme and indicate that (1) the spectral correction factors are nearly independent of the selection of three commonly used calibration sources: 252 Cf, 241 Am-Be and 239 Pu-Be; (2) the derived correction factors for Bonner spheres of various sizes (6''-9'') are similar in trend and (3) practical high-energy neutron indexes based on measurements can be established to facilitate the application of these correction factors in workplaces. (authors)

  11. Formation cross section of iron-60 with reactor neutrons in 59Fe(n, γ)60Fe reaction

    International Nuclear Information System (INIS)

    Sato, T.; Suzuki, T.

    1993-01-01

    Ingrowth of 60 Co radioactivity in an iron sample irradiated in a nuclear reactor has been measured for determination of formation cross section of 60 Fe in the 59 Fe(n, γ) 60 Fe reaction with reactor neutrons. After 5 years cooling, the irradiated iron was purified from 60 Co and other radioactive nuclides by an anion exchange separation method and isopropyl ether extraction in hydrochloric acid. The amount of 60 Co ingrowth was measured by γ-spectrometry using a Ge-detector coupled to a multichannel pulse height analyzer 4 years after the purification of iron. Neutron flux of the irradiation position was calculated from the amount of 55 Fe produced. The observed value of 12.5 ± 2.8 barn is slightly greater than reported value for burnup cross section of 59 Fe(n, x)X, where x refers γ, α, d, p and 2n, and X is any nuclide produced by the above reactions. (author) 8 refs.; 2 tabs

  12. Research on shielding neutron efficiency of some boron-bearing fabric and transparent resin materials

    International Nuclear Information System (INIS)

    Chen Changmao; Liu Jinhua; Su Jingling; Wang Zheng

    1995-01-01

    The shielding neutron efficiency of boron-bearing materials developed recently is introduced. The thermal neutron shield ratios for two kinds of non-woven cloth with thickness of 58 mg/cm 2 and 153 mg/cm 2 are 51% and 79% respectively. Their mass attenuation coefficient for 0.186, 24.4 and 144 keV neutron are 1.56, 1.29 and 0.9 cm 2 /g respectively. The thermal neutron shield ratio is 85% for the natural boron-bearing transparent resin plate with the thickness of 0.59 g/cm 2 , and 97% for enriched boron or gadolinium bearing resin plate. The shield ratios of all three materials for 24.4 keV neutrons are 38%. The transparence of natural light for enriched boron-bearing resin plates shows no considerable change after they were exposed to thermal neutrons up to 6 Sv. After they were exposed up to 20 Sv, the transparence decreases to 50% but thermal neutron shield ratio does not change. The gadolinium-bearing plate has a very strong thermal neutron-capture gamma radiation and its dose-equivalent is greater than that of incident thermal neutrons

  13. Integral test of neutron cross section data for future reactor materials through measurement and analysis of neutron spectra

    International Nuclear Information System (INIS)

    Mori, Takamasa

    1985-05-01

    In order to assess the cross section data for future reactor materials, such as molybdenum, niobium, titanium, lithium and fluorine, the angular neutron spectra in test piles of these materials or their chemical compounds have been measured in the energy range from a few keV to a few MeV by the linac time-of-flight method. The results have been compared with those theoretically calculated from the evaluated cross section data in such as JENDL-2 (or JENDL-1, JENDL-3PR1) and ENDF/B-IV. For both of molybdenum and niobium, it has been found that the energy distribution of inelastically scattered neutrons plays an important role in the analysis, and the JENDL library gives better predictions of spectrum shapes than ENDF/B-IV for both cases. In the case of niobium, however, it appears that the values of inelastic scattering cross section in JENDL-2 are too small around 2 MeV. It has been also found for niobium that the cross section data below 100 keV in ENDF/B-IV are inadequate. In a titanium pile, a discrepancy between the measured spectrum and the calculated one from ENDF/B-IV has been found in the energy range from about 60 keV to a few 100 keV. In order to investigate the cause of this discrepancy, the total cross sections for titanium have been measured by the transmission method. In the case of lithium, the discrepancy between the measured and calculated spectra is considerably reduced by adopting the angular distribution for 7 Li from ENDF/B-IV above about 500 keV. In the case of fluorine, spatial distributions of neutrons and X-rays have been also measured in both piles by the activation method to estimate the influence of photoneutrons generated in the sample material on the neutron distribution, and it has been found that their influence below 1 MeV is not so large as is necessary to be taken into account for the present assessment. (J.P.N)

  14. Application of low-cost Gallium Arsenide light-emitting-diodes as kerma dosemeter and fluence monitor for high-energy neutrons

    International Nuclear Information System (INIS)

    Mukherjee, B.; Simrock, S.; Khachan, J.; Rybka, D.; Romaniuk, R.

    2007-01-01

    Displacement damage (DD) caused by fast neutrons in unbiased Gallium Arsenide (GaAs) light emitting diodes (LED) resulted in a reduction of the light output. On the other hand, a similar type of LED irradiated with gamma rays from a 60 Co source up to a dose level in excess of 1.0 kGy (1.0 x 10 5 rad) was found to show no significant drop of the light emission. This phenomenon was used to develop a low cost passive fluence monitor and kinetic energy released per unit mass dosemeter for accelerator-produced neutrons. These LED-dosemeters were used to assess the integrated fluence of photoneutrons, which were contaminated with a strong Bremsstrahlung gamma-background generated by the 730 MeV superconducting electron linac driving the free electron laser in Hamburg (FLASH) at Deutsches Elektronen-Synchrotron. The applications of GaAs LED as a routine neutron fluence monitor and DD precursor for the electronic components located in high-energy accelerator environment are highlighted. (authors)

  15. Ion-Neutron Irradiated BOR60 Sample Preparation and Characterization: Nuclear Science User Facility 2017 Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Linton, Kory D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Parish, Chad M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smith, Quinlan B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    This document outlines the results obtained by Oak Ridge National Laboratory (ORNL) in collaboration with the University of Michigan-led Consolidated Innovative Nuclear Research project, “Feasibility of combined ion-neutron irradiation for accessing high dose levels.” In this reporting period, neutron irradiated were prepared and shipped to the University of Michigan for subsequent ion irradiation. The specimens were returned to ORNL’s Low Activation Materials Development and Analysis facility, prepared via focused ion beam for examination using scanning/transmission electron microscopy (S/TEM), and then examined using S/TEM to measure the as-irradiated microstructure. This report briefly summarizes the S/TEM results obtained at ORNL’s Low Activation Materials Development and Analysis facility.

  16. Distributions of neutron and gamma doses in phantom under a mixed field

    International Nuclear Information System (INIS)

    Beraud-Sudreau, E.

    1982-06-01

    A calculation program, based on Monte Carlo method, allowed to estimate the absorbed doses relatives to the reactor primary radiation, in a water cubic phantom and in cylindrical phantoms modelized from tissue compositions. This calculation is a theoretical approach of gamma and neutron dose gradient study in an animal phantom. PIN junction dosimetric characteristics have been studied experimentally. Air and water phantom radiation doses measured by PIN junction and lithium 7 fluoride, in reactor field have been compared to doses given by dosimetry classical techniques as tissue equivalent plastic and aluminium ionization chambers. Dosimeter responses have been employed to evaluate neutron and gamma doses in plastinaut (tissue equivalent plastic) and animal (piglet). Dose repartition in the piglet bone medulla has been also determined. This work has been completed by comparisons with Doerschell, Dousset and Brown results and by neutron dose calculations; the dose distribution related to lineic energy transfer in Auxier phantom has been also calculated [fr

  17. Intercomparison of radiation protection instruments based on microdosimetric principles

    International Nuclear Information System (INIS)

    Dietze, G.; Guldbakke, S.; Kluge, H.; Schmitz, T.

    1986-11-01

    Dosemeters based on low-pressure tissue-equivalent proportional counters were developed for the application in radiation protection area monitoring by several groups in Europe. Five different prototypes have been intercompared in a 60 Co photon field, in monoenergetic neutron fields with various energies between 73 keV and 5 MeV and in three neutron fields at a 252 Cf source moderated by a D 2 O sphere. This report describes the radiation fields, the measuring devices and first results of the intercomparison. Additional measurements with a system used in microdosimetry and with a conventional dose equivalent rate meter for neutrons (Rem Counter) were also described. (orig.) [de

  18. Hardening of single crystals of magnesium by low neutron doses at 77 K

    International Nuclear Information System (INIS)

    Gonzalez, H.C.

    1984-01-01

    Radiation hardening in Mg single crystals at 77 K is studied with a microtensile machine operating in-situ in the CNEA reactor facility RA1. Experimental results show that the dose dependence of the yield stress is similar to that previously observed in irradiated Cu and Zn. The radiation-induced yield stress, due to the presence of radiation obstacles operating alone, increases according to a 0.5 power law. It adds algebraically to the athermal component of the initial yield stress, but is not exactly additive to the other thermally activated mechanisms. For doses higher than 4.5 x 10 16 neutrons/cm 2 , a strong instability in the deformation is observed. Post irradiation experiments in tensile tests performed with a hard machine show a continuous stress drop. This effect is attributed to the dislocation channeling phenomenon which takes place during the tensile test. (author)

  19. Partial neutron capture cross sections of actinides using cold neutron prompt gamma activation analysis

    International Nuclear Information System (INIS)

    Genreith, Christoph

    2015-01-01

    Nuclear waste needs to be characterized for its safe handling and storage. In particular long-lived actinides render the waste characterization challenging. The results described in this thesis demonstrate that Prompt Gamma Neutron Activation Analysis (PGAA) with cold neutrons is a reliable tool for the non-destructive analysis of actinides. Nuclear data required for an accurate identification and quantification of actinides was acquired. Therefore, a sample design suitable for accurate and precise measurements of prompt γ-ray energies and partial cross sections of long-lived actinides at existing PGAA facilities was presented. Using the developed sample design the fundamental prompt γ-ray data on 237 Np, 241 Am and 242 Pu were measured. The data were validated by repetitive analysis of different samples at two individual irradiation and counting facilities - the BRR in Budapest and the FRM II in Garching near Munich. Employing cold neutrons, resonance neutron capture by low energetic resonances was avoided during the experiments. This is an improvement over older neutron activation based works at thermal reactor neutron energies. 152 prompt γ-rays of 237 Np were identified, as well as 19 of 241 Am, and 127 prompt γ-rays of 242 Pu. In all cases, both high and lower energetic prompt γ-rays were identified. The most intense line of 237 Np was observed at an energy of E γ =182.82(10) keV associated with a partial capture cross section of σ γ =22.06(39) b. The most intense prompt γ-ray lines of 241 Am and of 242 Pu were observed at E γ =154.72(7) keV with σ γ =72.80(252) b and E γ =287.69(8) keV with σ γ =7.07(12) b, respectively. The measurements described in this thesis provide the first reported quantifications on partial radiative capture cross sections for 237 Np, 241 Am and 242 Pu measured simultaneously over the large energy range from 45 keV to 12 MeV. Detailed uncertainty assessments were performed and the validity of the given uncertainties was

  20. Determination of cross sections for the production of low-energy monoenergetic neutron fields; Determination de sections efficaces pour la production de champs neutroniques monoenergetiques de basse energie

    Energy Technology Data Exchange (ETDEWEB)

    Lamirand, Vincent

    2011-11-18

    The response of a neutron detector, defined as the reading of the device per unit of incident fluence or dose, varies with neutron energy. The experimental determination of this variation, i.e. of the response function of this instrument, has to be performed by facilities producing monoenergetic neutron fields. These neutrons are commonly produced by interaction between accelerated ions (proton or deuteron) onto a thin target composed of a reactive layer deposited on a metallic backing. Using the {sup 7}Li(p, n), {sup 3}H(p, n), {sup 2}H(d, n) and {sup 3}H(d, n) reactions, monoenergetic neutrons are obtained between 120 keV and 20 MeV in the ion beam direction (0 deg.). To reach lower neutron energies, the angle of the measuring point with respect to the ion beam direction can be increased. However, this method presents several problems of neutron energy and fluence homogeneities over the detector surface, as well as an important increase of the scattered neutron contribution. Another solution is to investigate other nuclear reactions, as {sup 45}Sc(p, n) allowing to extend the neutron energy range down to 8 keV at 0 deg.. A complete study of this reaction and its cross section has been undertaken within the framework of a scientific cooperation between the laboratory of neutron metrology and dosimetry (IRSN, France), two European national metrological institutes, the National Physical Laboratory (UK) and the Physikalisch-Technische Bundesanstalt (Germany), and IRMM, the Institute for Reference Materials and Measurements (EC). In parallel, other possible reactions have been investigated: {sup 65}Cu(p, n), {sup 51}V(p, n), {sup 57}Fe(p, n), {sup 49}Ti(p, n), {sup 53}Cr(p, n) and {sup 37}Cl(p, n). They were compared in terms of neutron fluence and minimum energy of the produced neutrons. (author)

  1. A D-D neutron generator using a titanium drive-in target

    International Nuclear Information System (INIS)

    Kim, I.J.; Jung, N.S.; Jung, H.D.; Hwang, Y.S.; Choi, H.D.

    2008-01-01

    A D-D neutron generator was developed with an intensity of 10 8 n/s. A helicon plasma ion source was used to produce a large current deuteron beam, and neutrons were generated by irradiating the deuteron beam on a titanium drive-in target made of commercial pure titanium. The neutron generator was test-run for several hundred hours, and the performances were investigated. The available range of the deuteron beam current was 0.8-8 mA and the beam could be accelerated up to 97.5 keV. The maximum neutron generation rate in the test-runs was 1.9 x 10 8 n/s, which was achieved by irradiating a 7.6 mA deuteron beam at 94.0 keV on a 0.5 mm-thick target. The operation of the neutron generator was fairly stable, such that the neutron generation rate was not altered by high voltage breakdowns during the test-runs. Neutron generation efficiency was rated as low as 10% when compared to an ideal case of irradiating a 100% monatomic deuteron beam on a perfect TiD 2 target. Factors causing the low efficiency were suggested and discussed

  2. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ( 60 Co) and examines how these characteristics affect the behavior of 60 Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of 60 Co production, waste types, and waste forms that contain 60 Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom's nucleus. There is only one stable isotope of cobalt, namely 59 Co. All other cobalt isotopes, including 60 Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ( 54 Co-0.19 s) to 5.2 years ( 60 Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of 60 Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable 59 Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. 60 Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed

  3. Monte Carlo simulation of secondary neutron dose for scanning proton therapy using FLUKA.

    Directory of Open Access Journals (Sweden)

    Chaeyeong Lee

    Full Text Available Proton therapy is a rapidly progressing field for cancer treatment. Globally, many proton therapy facilities are being commissioned or under construction. Secondary neutrons are an important issue during the commissioning process of a proton therapy facility. The purpose of this study is to model and validate scanning nozzles of proton therapy at Samsung Medical Center (SMC by Monte Carlo simulation for beam commissioning. After the commissioning, a secondary neutron ambient dose from proton scanning nozzle (Gantry 1 was simulated and measured. This simulation was performed to evaluate beam properties such as percent depth dose curve, Bragg peak, and distal fall-off, so that they could be verified with measured data. Using the validated beam nozzle, the secondary neutron ambient dose was simulated and then compared with the measured ambient dose from Gantry 1. We calculated secondary neutron dose at several different points. We demonstrated the validity modeling a proton scanning nozzle system to evaluate various parameters using FLUKA. The measured secondary neutron ambient dose showed a similar tendency with the simulation result. This work will increase the knowledge necessary for the development of radiation safety technology in medical particle accelerators.

  4. NEUTRON GENERATOR FACILITY AT SFU: GEANT4 DOSE RATE PREDICTION AND VERIFICATION.

    Science.gov (United States)

    Williams, J; Chester, A; Domingo, T; Rizwan, U; Starosta, K; Voss, P

    2016-11-01

    Detailed dose rate maps for a neutron generator facility at Simon Fraser University were produced via the GEANT4 Monte Carlo framework. Predicted neutron dose rates throughout the facility were compared with radiation survey measurements made during the facility commissioning process. When accounting for thermal neutrons, the prediction and measurement agree within a factor of 2 or better in most survey locations, and within 10 % inside the vault housing the neutron generator. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Neutron dosimetry at nuclear power plants with light water reactors (LWR)

    International Nuclear Information System (INIS)

    Hofmann, B.; Schwarz, W.; Burgkhardt, B.; Piesch, E.

    1989-02-01

    During nuclear start-up of the Muelheim-Kaerlich nuclear power plant in 1986 the neutron radiation fields in the primary and auxiliary component rooms of the containment were investigated using the Single Sphere Albedo Technique and additional measurement techniques. For personnel monitoring albedo neutron dosemeters were used consisting of thermoluminescent detectors and track etch detectors combined with boron converters. Results: (1) The neutron radiation fields reach dose rate values up to 1000 mSv/h at the sleeves of the reactor coolant pipes, in the refuelling pool and the reactor cavity sump. The neutron component varies between 10% in the steam generator rooms up to 92% in the refuelling pool. (2) The mean value of the effective neutron energy at the different locations was found to be about 100 keV. Thermal neutrons contribute with about 10% to the area dose. (3) By direct intercomparisons and different evaluation methods of the Single Sphere Albedo Dosemeter it was shown, that rem-counters used within routine monitoring in the mixed radiation fields of the LWR overestimate the neutron dose rate only insignificantly (+20%) and are therefore usable for practical radiation protection work. (4) The sensitivity of albedo neutron dosemeters allows the detection of neutrons above 10 μSv. The contribution of neutrons to the total personnel dose was 25% in maximum. For the evaluation of albedo detectors a constant calibration factor can be applied. (orig./HP) [de

  6. Implementation of an Analytical Model for Leakage Neutron Equivalent Dose in a Proton Radiotherapy Planning System

    Energy Technology Data Exchange (ETDEWEB)

    Eley, John [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Graduate School of Biomedical Sciences, The University of Texas, 6767 Bertner Ave., Houston, TX 77030 (United States); Newhauser, Wayne, E-mail: newhauser@lsu.edu [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803 (United States); Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Homann, Kenneth; Howell, Rebecca [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Graduate School of Biomedical Sciences, The University of Texas, 6767 Bertner Ave., Houston, TX 77030 (United States); Schneider, Christopher [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803 (United States); Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Durante, Marco; Bert, Christoph [GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, Darmstadt 64291 (Germany)

    2015-03-11

    Equivalent dose from neutrons produced during proton radiotherapy increases the predicted risk of radiogenic late effects. However, out-of-field neutron dose is not taken into account by commercial proton radiotherapy treatment planning systems. The purpose of this study was to demonstrate the feasibility of implementing an analytical model to calculate leakage neutron equivalent dose in a treatment planning system. Passive scattering proton treatment plans were created for a water phantom and for a patient. For both the phantom and patient, the neutron equivalent doses were small but non-negligible and extended far beyond the therapeutic field. The time required for neutron equivalent dose calculation was 1.6 times longer than that required for proton dose calculation, with a total calculation time of less than 1 h on one processor for both treatment plans. Our results demonstrate that it is feasible to predict neutron equivalent dose distributions using an analytical dose algorithm for individual patients with irregular surfaces and internal tissue heterogeneities. Eventually, personalized estimates of neutron equivalent dose to organs far from the treatment field may guide clinicians to create treatment plans that reduce the risk of late effects.

  7. Neutral beam injector for 475 keV MARS sloshing ions

    International Nuclear Information System (INIS)

    Goebel, D.M.; Hamilton, G.W.

    1983-01-01

    A neutral beam injector system which produces 5 MW of 475 keV D 0 neutrals continuously on target has been designed. The beamline is intended to produce the sloshing ion distribution required in the end plug region of the conceptual MARS tandem mirror commercial reactor. The injector design utilizes the LBL self-extraction negative ion source and Transverse Field Focusing (TFF) accelerator to generate a long, ribbon ion beam. A laser photodetachment neutralizer strips over 90% of the negative ions. Magnetic and neutron shield designs are included to exclude the fringe fields of the end plug and provide low activation by the neutron flux from the target plasma. The use of a TFF accelerator and photodetachment neutralizer produces a total system electrical efficiency of about 63% for this design

  8. Measurements and calculations of neutron spectra and neutron dose distribution in human phantoms

    International Nuclear Information System (INIS)

    Palfalvi, J.

    1984-11-01

    The measurement and calculation of the radiation field around and in a phantom, with regard to the neutron component and the contaminating gamma radiation, are essential for radiation protection and radiotherapy purposes. The final report includes the development of the simple detector system, automized detector measuring facilities and a computerized evaluating system. The results of the depth dose and neutron spectra experiments and calculations in a human phantom are given

  9. Low doses of gamma radiation in soybean

    International Nuclear Information System (INIS)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C.; Arthur, Valter; Arthur, Paula B.; Franco, Caio H.

    2017-01-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  10. Low doses of gamma radiation in soybean

    Energy Technology Data Exchange (ETDEWEB)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C., E-mail: zegilmar60@gmail.com, E-mail: gilmita@uol.com.br, E-mail: villavic@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Caio H. [Universidade Federal de São Paulo (UNIFESP), SP (Brazil). Departamento de Microbiologia, Imunologia e Parasitologia

    2017-07-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  11. High resolution fast neutron spectrometry without time-of-flight

    International Nuclear Information System (INIS)

    Evans, A.E.; Brandenberger, J.D.

    1978-01-01

    Performance tests of a spectrometer tube of the type developed by Cuttler and Shalev show that the measurement of fast neutron spectra with this device can be made with an energy resolution previously obtainable only in large time-of-flight facilities. In preliminary tests, resolutions of 16.4 keV for thermal neutrons and 30.9 keV for 1-MeV neutrons were obtained. A broad-window pulse-shape discrimination (PSD) system is used to remove from pulse-height distributions most of the continua due to 3 He-recoil events, noise, and wall effect. Use of PSD improved the energy resolution to 12.9 keV for thermal neutrons and 29.2 keV for 1-MeV neutrons. The detector is a viable tool for neutron research at nominally equipped accelerator laboratories

  12. Application of Whole Body Counter to Neutron Dose Assessment in Criticality Accidents

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, O.; Tsujimura, N.; Takasaki, K.; Momose, T.; Maruo, Y. [Japan Nuclear Cycle Development Institute, Tokai (Japan)

    2001-09-15

    Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of {sup 24}Na in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of {sup 24}Na is approximately 50Bq for 10minute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 [(Bq{sup 24}Na/g{sup 23}Na)/mGy].

  13. Fast neutron dose equivalent rates in heavy ion target areas

    Energy Technology Data Exchange (ETDEWEB)

    Fulmer, C.B.; Butler, H.M.; Ohnesorge, W.F.; Mosko, S.W.

    1978-01-01

    At heavy ion accelerators, personnel access to areas near the target is sometimes important for successful performance of experiments. Radiation levels determine the amount of time that can be spent in these areas without exceeding maximum permissible exposures. Inasmuch as the fast neutrons contribute the major part of the Rem dose rates in these areas, knowledge of the fast neutron levels is important for planning permissive entry to target areas. Fast neutron dose rates were measured near thick medium mass targets bombarded with beams of C, N, O, and Ne ions. beam energies ranged from 3 to 16 MeV/amu. Dose rates (mrem/h) 1 meter from the target 90 degrees from the beam direction range from approx. 0.05 at MeV/amu to approx. 50 at 16 MeV/amu. These data should be helpful in planning permissive entry to heavy ion target areas.

  14. Fast neutron dose equivalent rates in heavy ion target areas

    International Nuclear Information System (INIS)

    Fulmer, C.B.; Butler, H.M.; Ohnesorge, W.F.; Mosko, S.W.

    1978-01-01

    At heavy ion accelerators, personnel access to areas near the target is sometimes important for successful performance of experiments. Radiation levels determine the amount of time that can be spent in these areas without exceeding maximum permissible exposures. Inasmuch as the fast neutrons contribute the major part of the Rem dose rates in these areas, knowledge of the fast neutron levels is important for planning permissive entry to target areas. Fast neutron dose rates were measured near thick medium mass targets bombarded with beams of C, N, O, and Ne ions. beam energies ranged from 3 to 16 MeV/amu. Dose rates (mrem/h) 1 meter from the target 90 degrees from the beam direction range from approx. 0.05 at MeV/amu to approx. 50 at 16 MeV/amu. These data should be helpful in planning permissive entry to heavy ion target areas

  15. High accuracy measurement of the $^{235}$U(n,f) reaction cross-section in the 10-30 keV neutron energy range

    CERN Multimedia

    The analysis of the neutron flux of n_TOF (in EAR1) revealed an anomaly in the 10-30 keV neutron energy range. While the flux extracted on the basis of the $^{6}$Li(n,t)$^{4}$He and $^{10}$B(n,$\\alpha$)$^{7}$Li reactions mostly agreed with each other and with the results of FLUKA simulations of the neutron beam, the one based on the $^{235}$U(n,f) reaction was found to be systematically lower, independently of the detection system used. A possible explanation is that the $^{235}$U(n,f) crosssection in that energy region, where in principle should be known with an uncertainty of 1%, may be systematically overestimated. Such a finding, which has a negligible influence on thermal reactors, would be important for future fast critical or subcritical reactors. Furthermore, its interest is more general, since the $^{235}$U(n,f) reaction is often used at that energy to determine the neutron flux, or as reference in measurements of fission cross section of other actinides. We propose to perform a high-accuracy, high-r...

  16. Nominal effective radiation doses delivered during clinical trials of boron neutron capture therapy

    International Nuclear Information System (INIS)

    Capala, J.; Diaz, A.Z.; Chanana, A.D.

    1997-01-01

    Boron neutron capture therapy (BNCT) is a binary system that, in theory, should selectively deliver lethal, high linear energy transfer (LET) radiation to tumor cells dispersed within normal tissues. It is based on the nuclear reaction 10-B(n, α)7-Li, which occurs when the stable nucleus of boron-10 captures a thermal neutron. Due to the relatively high cross-section of the 10-B nucleus for thermal neutron capture and short ranges of the products of this reaction, tumor cells in the volume exposed to thermal neutrons and containing sufficiently high concentration of 10-B would receive a much higher radiation dose than the normal cells contained within the exposed volume. Nevertheless, radiation dose deposited in normal tissue by gamma and fast neutron contamination of the neutron beam, as well as neutron capture in nitrogen, 14-N(n,p)14-C, hydrogen, 1-H(n,γ)2-H, and in boron present in blood and normal cells, limits the dose that can be delivered to tumor cells. It is, therefore, imperative for the success of the BNCT the dosed delivered to normal tissues be accurately determined in order to optimize the irradiation geometry and to limit the volume of normal tissue exposed to thermal neutrons. These are the major objectives of BNCT treatment planning

  17. Note on neutron scattering and the optical model near A = 208

    International Nuclear Information System (INIS)

    Guenther, P.; Havel, D.; Smith, A.

    1976-09-01

    Elastic neutron scattering cross sections of 206 Pb, 207 Pb, 208 Pb and 209 Bi are measured at incident neutron energy intervals of approx. 25 keV from 0.6 to 1.0 MeV with resolutions of approx. 25 keV. Optical model parameters are obtained from the energy-averaged experimental results for each of the isotopes. The observed elastic-neutron-scattering distributions and derived parameters for the lead isotopes (doubly magic or neutron holes in the closed shell) tend to differ from those of 209 Bi (doubly closed shell plus a proton). These potentials, derived in the approx. spherical region of A approximately 208, are extrapolated for the analysis of total and scattering cross sections of 238 U introducing only a small N-Z/A dependence and the known deformation of 238 U. Good descriptions of 238 U total cross sections are obtained from a few hundred keV to 10.0 MeV and the prediction of measured scattering distributions in the low MeV region are as suitable as frequently reported with other specially developed potentials

  18. Experimental neutron capture data of $^{58}$Ni from the CERN n_TOF facility

    CERN Document Server

    Žugec, P.; Colonna, N.; Bosnar, D.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M.A.; Diakaki, M.; Domingo-Pardo, C.; Duran, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A.R.; Giubrone, G.; Gómez-Hornillos, M.B.; Gonçalves, I.F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Jenkins, D.G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Langer, C.; Lederer, C.; Leeb, H.; Leong, L.S.; Losito, R.; Manousos, A.; Marganiec, J.; Martìnez, T.; Massimi, C.; Mastinu, P.F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P.M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Pignatari, M.; Plompen, A.; Praena, J.; Quesada, J.M.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Schillebeeckx, P.; Schmidt, S.; Tagliente, G.; Tain, J.L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M.J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.

    2013-01-01

    The $^{58}$Ni $(n,\\gamma)$ cross section has been measured at the neutron time of flight facility n_TOF at CERN, in the energy range from 27 meV up to 400 keV. In total, 51 resonances have been analyzed up to 122 keV. Maxwellian averaged cross sections (MACS) have been calculated for stellar temperatures of kT$=$5-100 keV with uncertainties of less than 6%, showing fair agreement with recent experimental and evaluated data up to kT = 50 keV. The MACS extracted in the present work at 30 keV is 34.2$\\pm$0.6$_\\mathrm{stat}\\pm$1.8$_\\mathrm{sys}$ mb, in agreement with latest results and evaluations, but 12% lower relative to the recent KADoNIS compilation of astrophysical cross sections. When included in models of the s-process nucleosynthesis in massive stars, this change results in a 60% increase of the abundance of $^{58}$Ni, with a negligible propagation on heavier isotopes. The reason is that, using both the old or the new MACS, 58Ni is efficiently depleted by neutron captures.

  19. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ({sup 60}Co) and examines how these characteristics affect the behavior of {sup 60}Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of {sup 60}Co production, waste types, and waste forms that contain {sup 60}Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom`s nucleus. There is only one stable isotope of cobalt, namely {sup 59}Co. All other cobalt isotopes, including {sup 60}Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ({sup 54}Co-0.19 s) to 5.2 years ({sup 60}Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of {sup 60}Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable {sup 59}Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. {sup 60}Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed.

  20. Low-dose-rate total lymphoid irradiation: a new method of rapid immunosuppression

    International Nuclear Information System (INIS)

    Blum, J.E.; de Silva, S.M.; Rachman, D.B.; Order, S.E.

    1988-01-01

    Total Lymphoid Irradiation (TLI) has been successful in inducing immunosuppression in experimental and clinical applications. However, both the experimental and clinical utility of TLI are hampered by the prolonged treatment courses required (23 days in rats and 30-60 days in humans). Low-dose-rate TLI has the potential of reducing overall treatment time while achieving comparable immunosuppression. This study examines the immunosuppressive activity and treatment toxicity of conventional-dose-rate (23 days) vs low-dose-rate (2-7 days) TLI. Seven groups of Lewis rats were given TLI with 60Co. One group was treated at conventional-dose-rates (80-110 cGy/min) and received 3400 cGy in 17 fractions over 23 days. Six groups were treated at low-dose-rate (7 cGy/min) and received total doses of 800, 1200, 1800, 2400, 3000, and 3400 cGy over 2-7 days. Rats treated at conventional-dose-rates over 23 days and at low-dose-rate over 2-7 days tolerated radiation with minimal toxicity. The level of immunosuppression was tested using allogeneic (Brown-Norway) skin graft survival. Control animals retained allogeneic skin grafts for a mean of 14 days (range 8-21 days). Conventional-dose-rate treated animals (3400 cGy in 23 days) kept their grafts 60 days (range 50-66 days) (p less than .001). Low-dose-rate treated rats (800 to 3400 cGy total dose over 2-7 days) also had prolongation of allogeneic graft survival times following TLI with a dose-response curve established. The graft survival time for the 3400 cGy low-dose-rate group (66 days, range 52-78 days) was not significantly different from the 3400 cGy conventional-dose-rate group (p less than 0.10). When the total dose given was equivalent, low-dose-rate TLI demonstrated an advantage of reduced overall treatment time compared to conventional-dose-rate TLI (7 days vs. 23 days) with no increase in toxicity

  1. Measurement of neutron and gamma absorbed doses in phantoms exposed to mixed fields

    International Nuclear Information System (INIS)

    Beraud-Sudreau, E.; Lemaire, G.; Maas, J.

    1985-01-01

    In order to study the dosimetric characteristics of PIN junctions, the absorbed doses measured by junctions and FLi7 in air and water phantoms were compared with the doses measured by classical neutron dosimetry in mixed fields. The validity of the experimental responses of PIN junctions being thus checked and established, neutron and gamma dose distributions in tissue equivalent plastic phantoms (plastinaut) and mammals (piglets) were evaluated as well as the absorbed dose distributions in the pig bone-marrow producing areas. By using correlatively a Monte-Carlo calculation method and applying some simplifying assumptions, the absorbed doses were derived from the spectrum of SILENE's neutrons at various depths inside a cubic water phantom and the results were compared with some from the literature [fr

  2. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  3. Measurement of 24.3 keV activation cross sections with the iron filter technique

    International Nuclear Information System (INIS)

    Rimawi, K.; Chrien, R.E.

    1975-01-01

    By using high-resolution detection techniques, intensities of specific activation lines from 197 Au(n,gamma), 238 U(n,gamma), 127 I(n,gamma), and 115 In(n,gamma) [54 min + 2.2 sec] were recorded, by using the BNL HFBR iron-filtered neutron beam. From a com- parison with the reaction 10 B(n,αgamma), cross sections at 24.3 keV were determined. (24.3 keV neutron activation cross sections, relative 10 B standard). (4 figures) (U.S.)

  4. Prediction analysis of dose equivalent responses of neutron dosemeters used at a MOX fuel facility

    International Nuclear Information System (INIS)

    Tsujimura, N.; Yoshida, T.; Takada, C.

    2011-01-01

    To predict how accurately neutron dosemeters can measure the neutron dose equivalent (rate) in MOX fuel fabrication facility work environments, the dose equivalent responses of neutron dosemeters were calculated by the spectral folding method. The dosemeters selected included two types of personal dosemeter, namely a thermoluminescent albedo neutron dosemeter and an electronic neutron dosemeter, three moderator-based neutron survey meters, and one special instrument called an H p (10) monitor. The calculations revealed the energy dependences of the responses expected within the entire range of neutron spectral variations observed in neutron fields at workplaces. (authors)

  5. Study and qualification of solid and gaseous captors designated to X imaging at around 60 keV; Etude et qualification de capteurs solide et gazeux en vue de leur utilisation en imagerie X autour de 60 keV

    Energy Technology Data Exchange (ETDEWEB)

    Ismaili, Y. [Caen Univ., 14 (France). Lab. de Physique Corpusculaire

    1996-09-01

    X ray detection techniques are used in numerous fields: industrial applications, security systems, scientific research and medicine. Among the medical applications, the dual energy detection of X-rays around 60 keV is used for bone densitometry. This thesis presents the design, realization and characterization of several kinds of detectors that could be suitable for X-ray imaging around 60 keV, bone densitometry being one the possible applications. The first part of this thesis is devoted to the realization of an original three-step gaseous detector coupled with a microchannel plate converter. The operating principle, the characteristics and the performance of such a bi-dimensional detector are discussed. Our study has allowed us to improve the efficiency by a factor of two, as compared to other systems based on the same principle. The obtained images have an excellent spatial resolution and can also be used to discriminate materials with different compositions. The work related to the study of a mono-dimensional detector constitutes the second part of the thesis. It is about the evaluation and optimization of a 8 element array made of Cd Te (Cadmium Telluride) which is a semi-conductor operating at room temperature. The tests carried-out with this detector show that it is a promising candidate for bone densitometry measurements. (author) 48 refs.

  6. Fast neutrons dosimetry

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1977-01-01

    A proton recoil technique has been developed for inducing thermoluminescence with incident fast neutrons. CaF 2 was used as the TL phosphor, and cane sugar and polyethylene were used as proton radiators. The phosphor and the hydrogeneous material powders were well mixed, encapsulated in glass tubes and exposed to Am-Be sources, resulting in recoils from incident fast neutrons of energy between 0,25 and 11,25 MeV. The intrinsic response of pure CaF 2 to fast neutrons without a hydrogeneous radiator was checked by using LiF (TLD-700). Glow curves were recorded from room temperature up to 350 0 C after different doses of neutrons and gamma rays of 60 Co. First collision dose due to fast neutrons in tissue like materials such as cane sugar and polyethylene was also calculated [pt

  7. Scaling neutron absorbed dose distributions from one medium to another

    International Nuclear Information System (INIS)

    Awschalom, M.; Rosenberg, I.; Ten Haken, R.K.

    1982-11-01

    Central axis depth dose (CADD) and off-axis absorbed dose ratio (OAR) measurements were made in water, muscle and whole skeletal bone TE-solutions, mineral oil and glycerin with a clinical neutron therapy beam. These measurements show that, for a given neutron beam quality and field size, there is a universal CADD distribution at infinity if the depth in the phantom is expressed in terms of appropriate scaling lengths. These are essentially the kerma-weighted neutron mean free paths in the media. The method used in ICRU No. 26 to scale the CADD by the ratio of the densities is shown to give incorrect results. the OAR's measured in different media at depths proportional to the respective mean free paths were also found to be independent of the media to a good approximation. It is recommended that relative CADD and OAR measurements be performed in water because of its universality and convenience. A table of calculated scaling lengths is given for various neutron energy spectra and for various tissues and materials of practical importance in neutron dosimetry

  8. Neutron activation analysis for calibration of phosphorus implantation dose

    International Nuclear Information System (INIS)

    Paul, Rick L.; Simons, David S.

    2001-01-01

    A feasibility study was undertaken to determine if radiochemical neutron activation analysis (RNAA) can be used to certify the retained dose of phosphorus implanted in silicon, with the goal of producing a phosphorus SRM. Six pieces of silicon, implanted with a nominal phosphorus dose of 8.5x10 14 atoms·cm -2 were irradiated at a neutron flux of 1.05x10 14 cm -2 ·s -1 . The samples were mixed with carrier, dissolved in acid, the phosphorus isolated by chemical separation, and 32 P measured using a beta proportional counter. A mean phosphorus concentration of (8.35±0.20)x10 14 atoms·cm -2 (uncertainty=1 standard deviation) was determined for the six samples, in agreement with the nominal implanted dose

  9. Quantitative analysis of biological responses to low dose-rate γ-radiation, including dose, irradiation time, and dose-rate

    International Nuclear Information System (INIS)

    Magae, J.; Furukawa, C.; Kawakami, Y.; Hoshi, Y.; Ogata, H.

    2003-01-01

    Full text: Because biological responses to radiation are complex processes dependent on irradiation time as well as total dose, it is necessary to include dose, dose-rate and irradiation time simultaneously to predict the risk of low dose-rate irradiation. In this study, we analyzed quantitative relationship among dose, irradiation time and dose-rate, using chromosomal breakage and proliferation inhibition of human cells. For evaluation of chromosome breakage we assessed micronuclei induced by radiation. U2OS cells, a human osteosarcoma cell line, were exposed to gamma-ray in irradiation room bearing 50,000 Ci 60 Co. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, cytoplasm and nucleus were stained with DAPI and propidium iodide, and the number of binuclear cells bearing micronuclei was determined by fluorescent microscopy. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [3H] thymidine was pulsed for 4 h before harvesting. Dose-rate in the irradiation room was measured with photoluminescence dosimeter. While irradiation time less than 24 h did not affect dose-response curves for both biological responses, they were remarkably attenuated as exposure time increased to more than 7 days. These biological responses were dependent on dose-rate rather than dose when cells were irradiated for 30 days. Moreover, percentage of micronucleus-forming cells cultured continuously for more than 60 days at the constant dose-rate, was gradually decreased in spite of the total dose accumulation. These results suggest that biological responses at low dose-rate, are remarkably affected by exposure time, that they are dependent on dose-rate rather than total dose in the case of long-term irradiation, and that cells are getting resistant to radiation after the continuous irradiation for 2 months. It is necessary to include effect of irradiation time and dose-rate sufficiently to evaluate risk

  10. Evaluation of neutron cross-sections of {sup 127}I important for radiation transport calculations in large NaI detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pronayaev, V G [Institute of Physics and Power Engineering, Obninsk (Russian Federation)

    1997-06-01

    Evaluations were made of neutron inelastic scattering cross-sections with excitation of discrete levels of the residual nucleus, the (n,2n) reaction, secondary neutron emission spectra and secondary photons for reactions which contribute substantially to production of photons for {sup 127}I with the use of the theoretical model for neutrons with an initial energy of 60 keV-20 MeV. (author). 10 refs, 3 figs.

  11. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4; Calculo de coeficientes de fluencia de neutrons para equivalente de dose individual utilizando o GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R., E-mail: rosanemribeiro@oi.com.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H{sub p} (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm{sup 3}, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm{sup 2}). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  12. Analysis of renal impairment in MM-003, a phase III study of pomalidomide + low - dose dexamethasone versus high - dose dexamethasone in refractory or relapsed and refractory multiple myeloma

    Science.gov (United States)

    Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina; Martinez-Lopez, Joaquin; Knop, Stefan; Yu, Xin; Hong, Kevin; Sternas, Lars; Jacques, Christian; Zaki, Mohamed H.; Miguel, Jesus San

    2016-01-01

    Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethasone; n=93, high-dose dexamethasone). Median progression-free survival was similar for both subgroups and favored pomalidomide + low-dose dexamethasone versus high-dose dexamethasone: 4.0 versus 1.9 months in the group with baseline creatinine clearance ≥ 30 − < 60 mL/min (P<0.001) and 4.0 versus 2.0 months in the group with baseline creatinine clearance ≥ 60 mL/min (P<0.001). Median overall survival for pomalidomide + low-dose dexamethasone versus high-dose dexamethasone was 10.4 versus 4.9 months (P=0.030) and 15.5 versus 9.2 months (P=0.133), respectively. Improved renal function, defined as an increase in creatinine clearance from < 60 to ≥ 60 mL/min, was similar in pomalidomide + low-dose dexamethasone and high-dose dexamethasone patients (42% and 47%, respectively). Improvement in progression-free and overall survival in these patients was comparable with that in patients without renal impairment. There was no increase in discontinuations of therapy, dose modifications, and adverse events in patients with moderate renal impairment. Pomalidomide at a starting dose of 4 mg + low-dose dexamethasone is well tolerated in patients with refractory or relapsed and refractory multiple myeloma, and of comparable efficacy if moderate renal impairment is present. This trial was registered with clinicaltrials.gov identifier 01311687 and EudraCT identifier 2010-019820-30. PMID:27081177

  13. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang [The First Affiliated Hospital of Zhengzhou University, Department of Radiology, Zhengzhou, Henan Province (China)

    2017-01-15

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  14. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

    International Nuclear Information System (INIS)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80) each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. (orig.)

  15. Stimulatory effects of low ionizing radiation on plant

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, S.; Kurisu, Y.; Murata, I.; Takahashi, A. [Department of Nuclear Engineering, Osaka Univ., Suita, Osaka (Japan); Masui, H.; Iida, T. [Department of Electronic, Information Systems and Energy Engineering, Osaka Univ., Suita, Osaka (Japan); Yamamoto, T. [Radioisotope Research Center, Osaka Univ., Suita, Osaka (Japan)

    2000-05-01

    Recently, the study for radiation hormesis was strongly carried out for animals and plants; subharmful dose of radiation may stimulate any organism. The concept of radiation hormesis effect consists of 1) biopositive effects of low dose radiation; influence caused by low dose radiation is totally different from one caused by high dose radiation, low dose radiation produces physiological useful effects against high dose radiation, and 2) radio-adaptive response; radiation also acts the organism as stress. Irradiated with small dose radiation previously, it raises its own defense response against the stress (radiation), resulting in the phenomenon that radiation influence decreases in appearance. In this paper we have investigated the phenomenon of radiation hormesis effects for plants through irradiation experiments with neutrons and gamma-rays to find out the mechanism. In the present experiment, dry seeds of Raphanus sativus were irradiated with D-T neutrons (10 {mu}Gy {approx} 100 kGy), D-D neutrons (1 mGy {approx} 100 mGy), thermal and fast neutrons (irradiation in a nuclear reactor: 100 {mu}Gy {approx} 10 Gy), 60Co gamma-rays (10 {mu}Gy {approx} 10 Gy). To confirm existence of the radiation hormesis effects, germination percentage, length of hypocotyl, length of root and total weight of seed leaf were measured at 7th day after starting cultivation. We estimated relative effectiveness as the hormesis effect, that is the ratio of mean values of measured subjects for the irradiated and control groups. For Raphanus sativus, the hormesis effect on seed leaf growth has been observed in the seed group irradiated by D-T neutrons and D-D neutrons. The observed hormesis effect is from 5 to 25 percents. (author)

  16. Dose-response relationship of dicentric chromosomes in human lymphocytes obtained for the fission neutron therapy facility MEDAPP at the research reactor FRM II.

    Science.gov (United States)

    Schmid, E; Wagner, F M; Romm, H; Walsh, L; Roos, H

    2009-02-01

    The biological effectiveness of neutrons from the neutron therapy facility MEDAPP (mean neutron energy 1.9 MeV) at the new research reactor FRM II at Garching, Germany, has been analyzed, at different depths in a polyethylene phantom. Whole blood samples were exposed to the MEDAPP beam in special irradiation chambers to total doses of 0.14-3.52 Gy at 2-cm depth, and 0.18-3.04 Gy at 6-cm depth of the phantom. The neutron and gamma-ray absorbed dose rates were measured to be 0.55 Gy min(-1) and 0.27 Gy min(-1) at 2-cm depth, while they were 0.28 and 0.25 Gy min(-1) at 6-cm depth. Although the irradiation conditions at the MEDAPP beam and the RENT beam of the former FRM I research reactor were not identical, neutrons from both facilities gave a similar linear-quadratic dose-response relationship for dicentric chromosomes at a depth of 2 cm. Different dose-response curves for dicentrics were obtained for the MEDAPP beam at 2 and 6 cm depth, suggesting a significantly lower biological effectiveness of the radiation with increasing depth. No obvious differences in the dose-response curves for dicentric chromosomes estimated under interactive or additive prediction between neutrons or gamma-rays and the experimentally obtained dose-response curves could be determined. Relative to (60)Co gamma-rays, the values for the relative biological effectiveness at the MEDAPP beam decrease from 5.9 at 0.14 Gy to 1.6 at 3.52 Gy at 2-cm depth, and from 4.1 at 0.18 Gy to 1.5 at 3.04 Gy at 6-cm depth. Using the best possible conditions of consistency, i.e., using blood samples from the same donor and the same measurement techniques for about two decades, avoiding the inter-individual variations in sensitivity or the differences in methodology usually associated with inter-laboratory comparisons, a linear-quadratic dose-response relationship for the mixed neutron and gamma-ray MEDAPP field as well as for its fission neutron part was obtained. Therefore, the debate on whether the fission-neutron

  17. Personnel neutron dose assessment upgrade: Volume 1, Personnel neutron dosimetry assessment: [Final report

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Brackenbush, L.W.; Griffith, R.V.; Hankins, D.E.; Parkhurst, M.A.; Stroud, C.M.; Faust, L.G.; Vallario, E.J.

    1988-07-01

    This report provides guidance on the characteristics, use, and calibration criteria for personnel neutron dosimeters. The report is applicable for neutrons with energies ranging from thermal to less than 20 MeV. Background for general neutron dosimetry requirements is provided, as is relevant federal regulations and other standards. The characteristics of personnel neutron dosimeters are discussed, with particular attention paid to passive neutron dosimetry systems. Two of the systems discussed are used at DOE and DOE-contractor facilities (nuclear track emulsion and thermoluminescent-albedo) and another (the combination TLD/TED) was recently developed. Topics discussed in the field applications of these dosimeters include their theory of operation, their processing, readout, and interpretation, and their advantages and disadvantages for field use. The procedures required for occupational neutron dosimetry are discussed, including radiation monitoring and the wearing of dosimeters, their exchange periods, dose equivalent evaluations, and the documenting of neutron exposures. The coverage of dosimeter testing, maintenance, and calibration includes guidance on the selection of calibration sources, the effects of irradiation geometries, lower limits of detectability, fading, frequency of calibration, spectrometry, and quality control. 49 refs., 6 figs., 8 tabs

  18. Seed irradiation with continuously increasing doses of thermal neutrons

    International Nuclear Information System (INIS)

    Uhlik, J.; Pfeifer, M.; Pittermann, P.

    1977-01-01

    In the 'Raman' pea cv. the biological activity of thermal neutrons was investigated after irradiation of a 780 mm column of seeds for 3000 and 4167 seconds with a flux of 5.607 x 10 9 n.cm -2 per second. For different fractions of the seed column the average density of the neutron flux was calculated. It was proved that for the described method of seed irradiation it was sufficient to determine only the dose approaching the lethal dose. If a sufficiently high column of seeds is used part of the column of seeds will be irradiated with the optimum range of doses. The advantages of the suggested method of irradiation are not only smaller time and technological requirements resulting from the need for the determination of only the critical lethal dose of radiation by means of inhibition tests performed with seedlings, but also a simpler irradiation procedure. The suggested method of irradiation is at least nine times cheaper. (author)

  19. Prompt-gamma spectrometry for the optimization of reactor neutron beams in biomedical research

    International Nuclear Information System (INIS)

    Borisov, G.I.; Komkov, M.M.; Leonov, V.F.

    1988-01-01

    In order to select the optimal spectral composition and size for the reactor neutron beams applied to in vivo analysis and therapy in biomedical research it is necessary to determine the spatial slow-neutron flux distributions produced by the beam in the irradiated object and to calculate or measure the neutron dose equivalents of both the original spectrum and the moderated neutrons. In this study the maximum neutron dose equivalents are found by spectrometry of the prompt-γ emission from the interaction of neutrons with atomic nuclei in the irradiated object. Different spectral distributions were produced by using an unfiltered beam together with filters of quartz, cadmium, 10 B, iron, aluminum, and sulfur. The phantom used was a tank filled with an aqueous solution of urea. Cadmium-containing organs were simulated. For in vivo neutron-activation analysis of human tissues at a depth of 2-5 cm it was found advisable to use neutrons of 20-40 keV mean energy with a beam area of at least 45 cm 2

  20. Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices

    Energy Technology Data Exchange (ETDEWEB)

    Filograna, Laura [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Institute of Radiology, Rome (Italy); University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland); Magarelli, Nicola; Leone, Antonio; Bonomo, Lorenzo [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Institute of Radiology, Rome (Italy); De Waure, Chiara; Calabro, Giovanna Elisa [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Research Centre for Health Technology Assessment, Department of Public Health, Section of Hygiene, Rome (Italy); Finkenstaedt, Tim [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Thali, Michael John [University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland)

    2016-07-15

    The objective was to evaluate the performances of dose-reduced dual-energy computed tomography (DECT) in decreasing metallic artifacts from orthopedic devices compared with dose-neutral DECT, dose-neutral single-energy computed tomography (SECT), and dose-reduced SECT. Thirty implants in 20 consecutive cadavers underwent both SECT and DECT at three fixed CT dose indexes (CTDI): 20.0, 10.0, and 5.0 mGy. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV, and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. In each group, the image quality of the seven monoenergetic images and of the SECT image was assessed qualitatively and quantitatively by visually rating and by measuring the maximum streak artifact respectively. The comparison between SECT and OPTkeV evaluated overall within all groups showed a significant difference (p <0.001), with OPTkeV images providing better images. Comparing OPTkeV with the other DECT images, a significant difference was shown (p <0.001), with OPTkeV and 130-keV images providing the qualitatively best results. The OPTkeV images of 5.0-mGy acquisitions provided percentages of images with scores 1 and 2 of 36 % and 30 % respectively, compared with 0 % and 33.3 % of the corresponding SECT images of 10- and 20-mGy acquisitions. Moreover, DECT reconstructions at the OPTkeV of the low-dose group showed higher CT numbers than the SECT images of dose groups 1 and 2. This study demonstrates that low-dose DECT permits a reduction of artifacts due to metallic implants to be obtained in a similar manner to neutral-dose DECT and better than reduced or neutral-dose SECT. (orig.)

  1. Genetic effects induced by neutrons in Drosophila melanogaster I. Determination of absorbed dose

    International Nuclear Information System (INIS)

    Delfin, A.; Paredes, L.C.; Zambrano, F.; Guzman-Rincon, J.; Urena-Nunez, F.

    2001-01-01

    A method to obtain the absorbed dose in Drosophila melanogaster irradiated in the thermal column facility of the Triga Mark III Reactor has been developed. The method is based on the measurements of neutron activation of gold foils produced by neutron capture to obtain the neutron fluxes. These fluxes, combined with the calculations of kinetic energy released per unit mass, enables one to obtain the absorbed doses in Drosophila melanogaster

  2. Measurementof photo-neutron dose from an 18-MV medical linac using a foil activation method in view of radiation protection of patients

    International Nuclear Information System (INIS)

    Yuecel, Haluk; Kolbasi, Asuman; Yueksel, Alptug Oezer; Cobanbas, Ibrahim; Kaya, Vildan

    2016-01-01

    High-energy linear accelerators are increasingly used in the medical field. However, the unwanted photo-neutrons can also be contributed to the dose delivered to the patients during their treatments. In this study, neutron fluxes were measured in a solid water phantom placed at the isocenter 1-m distance from the head of an 18-MV linac using the foil activation method. The produced activities were measured with a calibrated well-type Ge detector. From the measured fluxes, the total neutron fluence was found to be (1.17 ± 0.06) X 10 7 n/cm 2 per Gy at the phantom surface in a 20 X 20 cm 2 X-ray field size. The maximum photo-neutron dose was measured to be 0.67 ± 0.04 mSv/Gy at d max = 5 cm depth in the phantom at isocenter. The present results are compared with those obtained for different field sizes of 10 X 10cm 2 , 15 X 15cm 2 , and 20 X 20cm 2 from 10-, 15-, and 18-MV linacs. Additionally, ambient neutron dose equivalents were determined at different locations in the room and they were found to be negligibly low. The results indicate that the photo-neutron dose at the patient position is not a negligible fraction of the therapeutic photon dose. Thus, there is a need for reduction of the contaminated neutron dose by taking some additional measures, for instance, neutron absorbing-protective materials might be used as aprons during the treatment

  3. Radiosensitivity variations in human tumor cell lines exposed in vitro to p(66)/Be neutrons or 60Co γ-rays

    International Nuclear Information System (INIS)

    Slabbert, J.P.; Theron, T.; Serafin, A.; Jones, D.T.L.; Boehm, L.; Schmitt, G.

    1996-01-01

    Neutron therapy should be beneficial to patients with tumor types which are resistant to photons but relatively sensitive to high-LET radiation. In this work the potential therapeutic gain of a clinical neutron beam is evaluated by quantifying the variations in radiosensitivity of different cell lines to neutrons and photons. Different cell lines were exposed in vitro to p(66)/Be neutrons or 60 Co γ-rays. Micronuclei frequencies in binucleated cells and surviving fractions were determined for each cell type. Following exposure to either 1 or 1.5 Gy neutrons, micronuclei frequencies were significantly correlated with that observed for 2 Gy photons. A weak but significant correlation between the variation in neutron RBE values, determined from survival curve inactivation parameters and the mean inactivation doses for photon exposures, was also established. It is concluded that although neutron and photon sensitivities are related, the use of this high energy neutron source may constitute a potential therapeutic gain for tumor types that can be identified as very resistant to photons. Considering that a definitive oxygen gain factor has been established for this neutron beam the observed therapeutic gain is expected to be further enhanced in tumors where hypoxia protects cells from conventional radiation damage. (orig.) [de

  4. Effect of neutrons with an energy of 0.35 and 0.85 MeV and gamma radiation of 60Co on the organ cultures of the human bone marrow

    International Nuclear Information System (INIS)

    Zherbin, E.A.; Kolesnikova, A.I.; Konoplyannikov, A.G.; Khoptynskaya, S.K.; Obaturov, G.M.; Kapchigashev, S.P.

    1979-01-01

    A comparative study of the radiation injury of human hemopoietic cells under the effect of γ radiation of 60 Co in doses from 100 to 1500 rad, 0.85 MeV neutrons in doses from 50 to 600 rad and 0.35 MeV neutrons in doses from 30 to 600 rad was carried out using the method of organic cultivation of bone marrow. Under the effect of the above radiation types, the fissionable granulocytes (promyelocytes and myelocytes) and lymphocytes are most radiosensitive among the 4-day organic cultures. The dose dependence of the decrease in relative and absolute content of these cell forms in the cultures as well as the dose dependence of the decrease in total cell structure in the cultures were revealed. It has been found that the dose dependence for the above tests consists of two components: radiosensitive and radioresistant ones. The radiation doses causing death in 50% of cells in relation to control (D 50 ) were determined. On the bases of D 50 values, the coefficients of relative biological efficiency (RBE) were calculated for 0.85 and 0.35 MeV neutrons. The RBE coefficients are confined in the 1.4-3.4 and 2.4-6.7 intervals respectively. It has been confirmed that 0.35 MeV neutrons are 1.5-2 times more effective than 0.85 MeV neutrons. The coefficients of RBE neutrons calculated for radioresistant cell components are higher than the corresponding values estimated according to D 50 value; in some cases they reach values ranging from 6 to 10

  5. Relative Biological Effectiveness of 14-MeV Fast Neutrons to Co{sup 60} Gamma-Rays in Einkorn Wheat; Efficacite Biologique Relative des Neutrons Rapides de 14 MeV par Rapport aux Rayons Gamma de {sup 60}Co sur l'Engrain; Otnositel'naya biologicheskaya ehffektivnost' bystrykh nejtronov s ehnergiej 14 MeV i gamma-luchej CO{sup 60} pri ikh dejstvii na pshenitsu odnozernyanku; EBR de los Neutrones Rapidos de 14 MeV y de los Rayos Gamma del {sup 60}Co en el Trigo Escanda Menor

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Institute of Genetics, Misima (Japan)

    1964-05-15

    somatic mutation. (author) [French] L' auteur a etudie l'EBR des neutrons de 14 MeV par rapport aux rayons gamma de {sup 60}Co en appliquant a l'engrain la methode des loci specifiques. Il a utilise pour cette etude des semences Fi resultant du croisement entre l'espece originale et un mutant chlorina (le mutant chlorina e ta it le produit d'une mutation recessive induite par les rayons X ; depuis le stade de plantule jusqu'a sa maturite, le m utant a conserve une couleur vert c la ir uniforme ainsi qu'un taux de survie et une fe rtilite relativement eleves). Les plantes Fi avaient une couleur verte et une croissance normales. Des semences dormantes de F{sub 1} ont e te irradiees avec 0,5 , 1,0 et 1,4 krad de neutrons rapides et avec 4,3 , 8,6 et 12,9 krad de rayons gamma. Sous l'effet des deux types de rayonnements, il s'est produit des mutations de vert normal dominant en chlorina, sous forme de bandes longitudinales. Sur les feuilles et les tiges des heterozygotes X{sub 1}. Environ 80% des semences ont germe dans le lot temoin ainsi que dans les deux lots ayant recu la plus faible dose de neutrons et de rayons gamma; les taux de germination ont diminue a mesure qu'augmentaient les doses de neutrons et de rayons gamma. En outre, on a observe un phenomene analogue au debut de lacroissance de la plantule, qui etait progressivement inhibee a mesure qu'augmentait la dose de rayonnement. Les resultats obtenus montrent que l'irradiation par les neutrons est environ 13 fois plus efficace que celle par les rayons gamma. Le taux de survie des semences non irradiees du lo t temoin a e te de 90% environ; 60 a 80% des plantules ont survecu aux doses de 0,5 et 1,0 krad de neutrons; toutes les plantilles irradiees par les rayons gamma ont survecu. En revanche, 4% seulement des plantules ont survecu a 1,4 krad de neutrons. L'auteur n 'a pas observe de mutations chez les plantes du lo t temoin; le nombre des plantes a talles rayees a augmente en meme temps que les doses des deux types

  6. Calculation of neutron and gamma-ray flux-to-dose-rate conversion factors

    International Nuclear Information System (INIS)

    Kwon, S.G.; Lee, S.Y.; Yook, C.C.

    1981-01-01

    This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute (ANSI) N666. These data are used to calculate the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoenergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions. (author)

  7. Ramsauer effect in triplet neutron-neutron scattering

    International Nuclear Information System (INIS)

    Pupyshev, V.V.; Solovtsova, O.P.

    1995-01-01

    As we show, due to interplay of pure nuclear and magnetic moment interactions, the total cross section of triplet neutron-neutron scattering should possess a non-zero limit at E cm = 0 and a local minimum at ∼ 20 keV. 17 refs., 1 fig

  8. Evaluating secondary neutron doses of a refined shielded design for a medical cyclotron using the TLD approach

    International Nuclear Information System (INIS)

    Lin, Jye-Bin; Tseng, Hsien-Chun; Liu, Wen-Shan; Lin, Ding-Bang; Hsieh, Teng-San; Chen, Chien-Yi

    2013-01-01

    An increasing number of cyclotrons at medical centers in Taiwan have been installed to generate radiopharmaceutical products. An operating cyclotron generates immense amounts of secondary neutrons from reactions such the 18 O(p, n) 18 F, used in the production of FDG. This intense radiation can be hazardous to public health, particularly to medical personnel. To increase the yield of 18 F-FDG from 4200 GBq in 2005 to 48,600 GBq in 2011, Chung Shan Medical University Hospital (CSMUH) has prolonged irradiation time without changing the target or target current to meet requirements regarding the production 18 F. The CSMUH has redesigned the CTI Radioisotope Delivery System shield. The lack of data for a possible secondary neutron doses has increased due to newly designed cyclotron rooms. This work aims to evaluate secondary neutron doses at a CTI cyclotron center using a thermoluminescent dosimeter (TLD-600). Two-dimensional neutron doses were mapped and indicated that neutron doses were high as neutrons leaked through self-shielded blocks and through the L-shaped concrete shield in vault rooms. These neutron doses varied markedly among locations close to the H 2 18 O target. The Monte Carlo simulation and minimum detectable dose are also discussed and demonstrated the reliability of using the TLD-600 approach. Findings can be adopted by medical centers to identify radioactive hot spots and develop radiation protection. - Highlights: • Neutron doses were verified using TLD approach. • Neutron doses were increased at cyclotron centers. • Revised L-shaped shield suppresses effectively the neutrons. • Neutron dose can be attenuated to 1.13×10 6 %

  9. Dose-rate effects of low-dropout voltage regulator at various biases

    International Nuclear Information System (INIS)

    Wang Yiyuan; Zheng Yuzhan; Gao Bo; Chen Rui; Fei Wuxiong; Lu Wu; Ren Diyuan

    2010-01-01

    A low-dropout voltage regulator, LM2941, was irradiated by 60 Co γ-rays at various dose rates and biases for investigating the total dose and dose rate effects. The radiation responses show that the key electrical parameters, including its output and dropout voltage, and the maximum output current, are sensitive to total dose and dose rates, and are significantly degraded at low dose rate and zero bias. The integrated circuits damage change with the dose rates and biases, and the dose-rate effects are relative to its electric field. (authors)

  10. Secondary Electrons from Water Vapor with the Impact of 6.0 MeV/u He2+ Ions: Atomic Data and their Application to Biomedical Investigations

    International Nuclear Information System (INIS)

    Sato, Y.; Soga, F.; Ohsawa, D.; Higashi, A.; Kawauchi, H.; Hirabayashi, M.; Okada, Y.; Uehara, S.; Nikjoo, H.

    2005-01-01

    We measured the energy and angular distributions (7 eV-10 keV and 20 degree sign -160 degree sign ) of secondary electrons produced in collisions of 6.0 MeV/u He2+ ions with water vapor. Binary-encounter collision peaks were clearly observed at the calculated energies at angles of 3keV. To assess the new cross sections, these values were incorporated in the kurbuc Monte-Carlo track structure code system for a simulation of secondary electrons. Radial dose distributions for 6.0 MeV/u He2+ ions were obtained by analyzing the tracks generated by the code kurbuc using the new DDCS values. In the core with a radius (r) of less than 1 nm, the dose is very high due mainly to excitation events, induced by low-energy electrons. The penumbra shows a well-known r-2 dependence

  11. Study and qualification of solid and gaseous captors designated to X imaging at around 60 keV

    International Nuclear Information System (INIS)

    Ismaili, Y.

    1996-09-01

    X ray detection techniques are used in numerous fields: industrial applications, security systems, scientific research and medicine. Among the medical applications, the dual energy detection of X-rays around 60 keV is used for bone densitometry. This thesis presents the design, realization and characterization of several kinds of detectors that could be suitable for X-ray imaging around 60 keV, bone densitometry being one the possible applications. The first part of this thesis is devoted to the realization of an original three-step gaseous detector coupled with a microchannel plate converter. The operating principle, the characteristics and the performance of such a bi-dimensional detector are discussed. Our study has allowed us to improve the efficiency by a factor of two, as compared to other systems based on the same principle. The obtained images have an excellent spatial resolution and can also be used to discriminate materials with different compositions. The work related to the study of a mono-dimensional detector constitutes the second part of the thesis. It is about the evaluation and optimization of a 8 element array made of Cd Te (Cadmium Telluride) which is a semi-conductor operating at room temperature. The tests carried-out with this detector show that it is a promising candidate for bone densitometry measurements. (author)

  12. Measurement of two-dimensional thermal neutron flux in a water phantom and evaluation of dose distribution characteristics

    International Nuclear Information System (INIS)

    Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Horiguchi, Yoji

    2001-03-01

    To evaluate nitrogen dose, boron dose and gamma-ray dose occurred by neutron capture reaction of the hydrogen at the medical irradiation, two-dimensional distribution of the thermal neutron flux is very important because these doses are proportional to the thermal neutron distribution. This report describes the measurement of the two-dimensional thermal neutron distribution in a head water phantom by neutron beams of the JRR-4 and evaluation of the dose distribution characteristic. Thermal neutron flux in the phantom was measured by gold wire placed in the spokewise of every 30 degrees in order to avoid the interaction. Distribution of the thermal neutron flux was also calculated using two-dimensional Lagrange's interpolation program (radius, angle direction) developed this time. As a result of the analysis, it was confirmed to become distorted distribution which has annular peak at outside of the void, though improved dose profile of the deep direction was confirmed in the case which the radiation field in the phantom contains void. (author)

  13. American National Standard: neutron and gamma-ray flux-to-dose rate factors

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard presents data recommended for computing biological dose rates due to neutron and gamma-ray radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are given; the energy range for the gamma-ray conversion factors is 0.01 to 15 MeV. Specifically, this Standard is intended for use by shield designers to calculate wholebody dose rates to radiation workers and the general public. Establishing dose-rate limits is outside the scope of this Standard. Use of this Standard in cases where the dose equivalents are far in excess of occupational exposure guidelines is not recommended

  14. Biological influence from low dose and low-dose rate radiation

    International Nuclear Information System (INIS)

    Magae, Junji

    2007-01-01

    Although living organisms have defense mechanisms for radioadaptive response, the influence is considered to vary qualitatively and quantitatively for low dose and high dose, as well as for low-dose rate and high-dose rate. This article describes the bioresponse to low dose and low-dose rate. Among various biomolecules, DNA is the most sensitive to radiation, and accurate replication of DNA is an essential requirement for the survival of living organisms. Also, the influence of active enzymes resulted from the effect of radiation on enzymes in the body is larger than the direct influence of radiation on the body. After this, the article describes the carcinogenic risk by low-dose radiation, and then so-called Hormesis effect to create cancer inhibition effect by stimulating active physiology. (S.K.)

  15. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  16. Experimental test of a newly developed single-moderator, multi-detector, directional neutron spectrometer in reference monochromatic fields from 144 keV to 16.5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Gómez-Ros, J.M. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Pola, A.; Bortot, D. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Gentile, A. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Introini, M.V. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Buonomo, B. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN – Milano, Via Celoria 16, 20133 Milano (Italy); Mazzitelli, M. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); Sacco, D. [INFN – LNF, via E. Fermi n. 40, 00044 Frascati (Roma) (Italy); INAIL – DPIA, Via di Fontana Candida n.1, 00040 Monteporzio Catone (Italy)

    2015-05-11

    A new directional neutron spectrometer called CYSP (CYlindrical SPectrometer) was developed within the NESCOFI@BTF (2011–2013) collaboration. The device, composed by seven active thermal neutron detectors located along the axis of a cylindrical moderator, was designed to simultaneously respond from the thermal domain up to hundreds of MeV neutrons. The new spectrometer condenses the performance of the Bonner Sphere Spectrometer in a single moderator; thus requiring only one exposure to determine the whole spectrum. The CYSP response matrix, determined with MCNP, has been experimentally evaluated with monochromatic reference neutron fields from 144 keV to 16.5 MeV, plus a {sup 252}Cf source, available at NPL (Teddington, UK). The results of the experiment confirmed the correctness of the response matrix within an overall uncertainty of ±2.5%. The new active spectrometer CYSP offers an innovative option for real-time monitoring of directional neutron fields as those produced in neutron beam-lines.

  17. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4

    International Nuclear Information System (INIS)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R.

    2014-01-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H p (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm 3 , composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm 2 ). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  18. Neutron spectra and dosimetric features of isotopic neutron sources: a review

    International Nuclear Information System (INIS)

    Vega C, H. R.; Martinez O, S. A.

    2015-10-01

    A convenient way to produce neutrons is the isotopic neutron source, where the production is through (α, n), (γ, n), and spontaneous fission reactions. Isotopic neutron sources are small, easy to handle, and have a relative low cost. On the other hand the neutron yield is small and mostly of them produces neutrons with a wide energy distribution. In this work, a review is carried out about the the main features of 24 NaBe, 24 NaD 2 O, 116 InBe, 140 LaBe, 238 PuLi, 239 PuBe, 241 AmB, 241 AmBe, 241 AmF, 241 AmLi, 242 CmBe, 210 PoBe, 226 RaBe, 252 Cf and 252 Cf/D 2 O isotopic neutron source. Also, using Monte Carlo methods, the neutron spectra in 31 energy groups, the neutron mean energy; the Ambient dose equivalent, the Personal dose equivalent and the Effective dose were calculated for these isotopic neutron sources. (Author)

  19. Estimate of neutron secondary doses received by patients in proton therapy: cases of ophthalmologic treatments

    International Nuclear Information System (INIS)

    Martinetti, F.

    2009-12-01

    This research thesis aims at assessing doses due to secondary neutrons and received by the organs of a patient which are located outside of the treatment field. The study focused on ophthalmological treatments performed at the Orsay proton therapy centre. A 75 eV beam line model has first been developed with the MCNPX Monte Carlo code. Several experimental validations of this model have been performed: proton dose distribution in a water phantom, ambient equivalent dose due to secondary neutrons and neutron spectra in the treatment room, and doses deposited by secondary neutrons in an anthropomorphous phantom. Simulations and measurements are in correct agreement. Then, a numeric assessment of secondary doses received by the patient's organs has been performed by using a MIRD-type mathematical phantom. These doses have been computed for several organs: the non-treated eye, the brain, the thyroid, and other parts of the body situated either in the front part of the body (the one directly exposed to neutrons generated in the treatment line) or deeper and further from the treatment field

  20. Effect of low 60Co dose rates on sister chromatid exchange incidence in the benthic worm. Neanthes arenaceodentata

    International Nuclear Information System (INIS)

    Harrison, F.L.; Rice, D.W. Jr.

    1981-01-01

    The usefulness of sister chromatid exchange (SCE) induction as a measure of low-level radiation effect was examined in a benthic marine worm, Neanthes arenaceodentata. Larvae were exposed to 60 Co radiation for 12 to 24 h at total doses ranging from 0.5 to 309 R and at dose rates from 0.04 to 13 R/h. Animals exposed at intermediate dose rates (0.5, 0.6, 1.25, 2.0, and 2.5 R/h) had SCE frequencies per chromosome about twice that of those receiving no radiation (controls), whereas those exposed at the higher dose rates (7.0 and 13 R/h) had SCE frequencies lower than the controls. Animals exposed at the lower dose rates (0.04 and 0.1 R/h) had lower SCE frequencies than those exposed at intermediate dose rates (and higher SCE frequencies than controls). The length of chromosome pair number one differed among metaphase spreads and was used as an index of chromosome condensation in a given metaphase. Because there is a possibility that chromosome morphology may affect the ability to resolve SCEs, morphology will be monitored in future studies. A preliminary experiment was performed to assess the effects of 2.2 and 11.5 R/h for 24 h on growth and development. Larvae observed at 6 and 17 d after irradiation did not have significantly different numbers of abnormal larvae or survival rates

  1. Investigation of dose distribution in mixed neutron-gamma field of boron neutron capture therapy using N isopropylacrylamide gel

    Energy Technology Data Exchange (ETDEWEB)

    Bavarmegin, Elham; Sadremomtaz, Alireza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Khalafi, Hossein; Kasesaz, Yaser [Dept. of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Khajeali, Azim [Medical Education Research Center, Tabriz (Iran, Islamic Republic of)

    2017-02-15

    Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the R2 maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

  2. Boron neutron capture irradiation of the rat spinal cord: effects of variable doses of borocaptate sodium

    International Nuclear Information System (INIS)

    Morris, Gerard M.; Coderre, Jeffrey A.; Hopewell, John W.; Micca, Peggy L.; Fisher, Craig

    1996-01-01

    The Fischer 344 rat spinal cord model has been used to evaluate the response of the central nervous system to boron neutron capture irradiation with variable doses of the neutron capture agent, borocaptate sodium (BSH). Three doses of BSH, 190, 140 and 80 mg/kg body weight, administered by i.p. injection, were used to establish the time course of 10 B accumulation in and removal from the blood. After administration of the two lower doses of BSH, blood 10 B levels peaked at 0.5 h after injection, with no significant (P > 0.1) change at 1 h after injection. Beyond this time point, levels of 10 B in the blood began to decrease after a dose of 80 mg/kg BSH, but remained constant until 3 h after administration after the two higher doses of BSH. Myelopathy developed after latent intervals of 20.4 ± 0.1, 20.8 ± 1.4, 15.0 ± 0.8, 15.4 ± 0.4 and 15.6 ± 0.4 weeks, following irradiation with thermal neutrons in combination with BSH at doses of 20, 40, 80, 140 and 190 mg/kg body weight, respectively. The radiation-induced lesion in the spinal cord was white matter necrosis. ED 50 values for myelopathy were calculated from probit-fitted dose-effect curves. Expressed as total physical absorbed doses, these values were 20.7 ± 1.9, 24.9 ± 1.2, 27.2 ± 0.9, 28.4 ± 0.6 and 32.4 ± 1.9 Gy after irradiation with thermal neutrons in the presence of 20, 40, 80, 140 and 190 mg/kg body weight of BSH, respectively. The compound biological effectiveness (CBE) factor values, estimated from this data, were in the range 0.49-0.55. There was no significant (P >0.1) variation in the CBE factor for BSH as a function of increasing 10 B concentration in the blood. It was concluded that there was no significant synergistic interaction between the low and high linear energy transfer (LET) components of the boron neutron capture (BNC) radiation field

  3. Disintegration of C60 by Xe ion irradiation

    International Nuclear Information System (INIS)

    Kalish, R.; Samoiloff, A.; Hoffman, A.; Uzan-Saguy, C.

    1993-01-01

    The Changes in resistivity of fullerene (C 60 ) films subject to 320 keV Xe ion irradiation are investigated as a function of ion dose. From a comparison of this dependence with similar data on other Xe irradiated C containing insulating materials and with data on C implanted fused quartz, it is concluded that upon ion impact C 60 clusters completely disintegrate. This disintegration releases about 60 C atoms which disperse amongst the remaining intact C 60 spheres giving rise to hopping conductivity between isolated C atoms. 16 refs., 3 figs

  4. Promoting growth of fry and adult fish by irradiating fish embryos with low-dose of Ra-Be neutron source

    International Nuclear Information System (INIS)

    Yu Yongcheng; Zhang Yuhua; Wu Jilan

    1994-01-01

    Proper neutron dose can stimulate fries to grow. The optimum neutron fluence is from 9.2 x 10 5 cm -2 to 18 x 10 5 cm -2 . The yield of fries is increased by 16%-24% (silver carp fries) and 6%-30% (carp fries). The cultivated period of the treated silver carp fries is shortened by 28-45 days (1/3 to 1/2 period). The irradiated embryos of silver carp and carp are reared and produced for commercial adult fish in 1992

  5. Improvement of voltage holding capability in the 500 keV negative ion source for JT-60SA.

    Science.gov (United States)

    Tanaka, Y; Hanada, M; Kojima, A; Akino, N; Shimizu, T; Ohshima, K; Inoue, T; Watanabe, K; Taniguchi, M; Kashiwagi, M; Umeda, N; Tobari, H; Grisham, L R

    2010-02-01

    Voltage holding capability of JT-60 negative ion source that has a large electrostatic negative ion accelerator with 45 cm x 1.1 m acceleration grids was experimentally examined and improved to realize 500 keV, 22 A, and 100 s D- ion beams for JT-60 Super Advanced. The gap lengths in the acceleration stages were extended to reduce electric fields in a gap between the large grids and at the corner of the support flanges from the original 4-5 to 3-4 kV/mm. As a result, the voltage holding capability without beam acceleration has been successfully improved from 400 to 500 kV. The pulse duration to hold 500 kV reached 40 s of the power supply limitation.

  6. Isotopic composition of uranium in U3O8 by neutron induced reactions utilizing thermal neutrons from critical facility and high resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Acharya, R.; Pujari, P.K.; Goel, Lokesh

    2015-01-01

    Uranium in oxide and metal forms is used as fuel material in nuclear power reactors. For chemical quality control, it is necessary to know the isotopic composition (IC) of uranium i.e., 235 U to 238 U atom ratio as well as 235 U atom % in addition to its total concentration. Uranium samples can be directly assayed by passive gamma ray spectrometry for obtaining IC by utilizing 185 keV (γ-ray abundance 57.2%) of 235 U and 1001 keV (γ-ray abundance 0.837%) of 234m Pa (decay product of 238 U). However, due to low abundance of 1001 keV, often it is not practiced to obtain IC by this method as it gives higher uncertainty even if higher mass of sample and counting time are used. IC of uranium can be determined using activity ratio of neutron induced fission product of 235 U to activation product of 238 U ( 239 Np). In the present work, authors have demonstrated methodologies for determination of IC of U as well as 235 U atom% in natural ( 235 U 0.715%) and low enriched uranium (LEU, 3-20 atom % of 235 U) samples of uranium oxide (U 3 O 8 ) by utilizing ratio of counts at 185 keV γ-ray or γ-rays of fission products with respect to 277 keV of 239 Np. Natural and enriched samples (about 25 mg) were neutron irradiated for 4 hours in graphite reflector position of AHWR Critical Facility (CF) using highly thermalized (>99.9% thermal component) neutron flux (∼10 7 cm -2 s -1 )

  7. Use of borated polyethylene to improve low energy response of a prompt gamma based neutron dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Priyada, P.; Ashwini, U.; Sarkar, P.K., E-mail: pradip.sarkar@manipal.edu

    2016-05-21

    The feasibility of using a combined sample of borated polyethylene and normal polyethylene to estimate neutron ambient dose equivalent from measured prompt gamma emissions is investigated theoretically to demonstrate improvements in low energy neutron dose response compared to only polyethylene. Monte Carlo simulations have been carried out using the FLUKA code to calculate the response of boron, hydrogen and carbon prompt gamma emissions to mono energetic neutrons. The weighted least square method is employed to arrive at the best linear combination of these responses that approximates the ICRP fluence to dose conversion coefficients well in the energy range of 10{sup −8} MeV to 14 MeV. The configuration of the combined system is optimized through FLUKA simulations. The proposed method is validated theoretically with five different workplace neutron spectra with satisfactory outcome. - Highlights: • An improved method is proposed for estimating H⁎(10) using prompt gamma emissions. • A combination of BHDPE and HDPE cylinders is used as a sample. • Linear combination of prompt gamma intensities approximates ICRP-DCC closely. • Feasibility of the method was tested theoretically using workplace neutron spectra.

  8. Thermal-mechanical design of a 150-mA, direct-current, 400-keV accelerator for production of 14-MeV neutrons

    International Nuclear Information System (INIS)

    Hanson, C.L.

    1977-01-01

    Several unique accelerator components were designed and built for the Rotating Target Neutron Source Facility at the Lawrence Livermore Laboratory. Particular consideration was given to material selection and cooling design of components because the facility will have a large steady-state beam energy. Components discussed include the system composed of the ion source and 90-deg double-focusing magnet in the high-voltage terminal, a water-cooled 400-keV acceleration column, a pyrolytic-graphite beam collimator, and quick-disconnect beam-tube couplings

  9. A coaxial double cylindrical TEPC for the microdosimetry of selected neutron energy bands in mixed fields of fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Saion, E.B.; Watt, D.E. (Saint Andrews Univ. (UK). Dept. of Physics); East, B.W. (Scottish Universities Research and Reactor Centre, Glasgow (UK)); Colautti, P. (Istituto Nazionale di Fisica Nucleare, Padua (Italy))

    1990-01-01

    A new low pressure tissue-equivalent proportional counter (TEPC) in a coaxial double cylindrical form has been developed to measure separately the microdose spectrum from any desired energy band of neutrons in the presence of mixed fields of faster neutrons, by selecting the thickness of the common TE dividing wall to be equivalent to the corresponding maximum proton ranges and by appropriate use of coincidence/anti-coincidence pulse arrangements. This thickness ensures charged particle equilibrium for the relevant neutron energy. Event spectra due to recoils generated by faster neutrons which interact with both the counters are removed completely by anti-coincidence techniques, thereby optimising the sensitivity of the inner microdosemeter to the event spectra of interest. The ability of this counter to discriminate in favour of events due to neutrons of energy <850 keV was achieved in microdosimetric measurements from mixed fields of a nuclear reactor. Mean values of lineal energy and quality factor for neutrons of energy <850 keV from a nuclear reactor were determined from the anti-coincidence spectrum. Good discrimination against {gamma} ray induced events is also achieved for the spectrum recorded in the anti-coincidence mode. This is an advantageous feature for other applications and requires further investigation. (author).

  10. A coaxial double cylindrical TEPC for the microdosimetry of selected neutron energy bands in mixed fields of fast neutrons

    International Nuclear Information System (INIS)

    Saion, E.B.; Watt, D.E.; Colautti, P.

    1990-01-01

    A new low pressure tissue-equivalent proportional counter (TEPC) in a coaxial double cylindrical form has been developed to measure separately the microdose spectrum from any desired energy band of neutrons in the presence of mixed fields of faster neutrons, by selecting the thickness of the common TE dividing wall to be equivalent to the corresponding maximum proton ranges and by appropriate use of coincidence/anti-coincidence pulse arrangements. This thickness ensures charged particle equilibrium for the relevant neutron energy. Event spectra due to recoils generated by faster neutrons which interact with both the counters are removed completely by anti-coincidence techniques, thereby optimising the sensitivity of the inner microdosemeter to the event spectra of interest. The ability of this counter to discriminate in favour of events due to neutrons of energy <850 keV was achieved in microdosimetric measurements from mixed fields of a nuclear reactor. Mean values of lineal energy and quality factor for neutrons of energy <850 keV from a nuclear reactor were determined from the anti-coincidence spectrum. Good discrimination against γ ray induced events is also achieved for the spectrum recorded in the anti-coincidence mode. This is an advantageous feature for other applications and requires further investigation. (author)

  11. On the mechanisms of action of high and superhigh doses of γ-quanta and neutrons of the central nervous system

    International Nuclear Information System (INIS)

    Lavrova, G.A.; Pushkareva, T.V.; Nikanorova, N.G.; Sverdlov, A.G.

    1984-01-01

    Wistar rats were exposed to γ-quanta ( 60 Co, 100-400 Gy) and neutrons (100-200 Gy). The C. N. S. syndrome was shown to develop the neuron lesions being relatively minor. With a reference to this index, the RBE of neutrons was 1.75. The permeability of blood vessels of the brain was decreased during the development of the C. N. S. -syndrome. Disturbances in the functional state of neurons and interneuron reactions, including the changes in the mediator metabolism (these changes were manifested by the increased GABA content of the cerebellum), play, in all appearance, an important role in the impairment of the brain function under the effect of high doses of neutrons and γ-quanta

  12. Reaction rate of the 13C(α,n)16O neutron source using the ANC of the -3 keV resonance measured with the THM

    International Nuclear Information System (INIS)

    La Cognata, M; Spitaleri, C; Trippella, O; Kiss, G G; Guardo, G L; Puglia, S M R; Romano, S; Spartà, R; Rogachev, G V; Avila, M; Koshchiy, E; Kuchera, A; Santiago, D; Mukhamedzhanov, A M; Lamia, L

    2016-01-01

    The s-process is responsible of the synthesis of most of the nuclei in the mass range 90 ≤ A ≤ 208. It consists in a series of neutron capture reactions on seed nuclei followed by β-decays, since the neutron accretion rate is slower than the β-decay rate. Such small neutron flux is supplied by the 13 C(α,n) 16 O reaction. It is active inside the helium-burning shell of asymptotic giant branch stars, at temperatures < 10 8 K, corresponding to an energy interval of 140–230 keV. In this region, the astrophysical S (E)-factor is dominated by the −3 keV sub-threshold resonance due to the 6.356 MeV level in 17 O. In this work, we have applied the Trojan Horse Method (THM) to the 13 C( 6 Li,n 16 O)d quasi-free reaction to extract the 6.356 MeV level resonance parameters, in particular the asymptotic normalization coefficient . A preliminary analysis of a partial data set has lead to , slightly larger than the values in the literature. However, the deduced 13 C(α, n) 16 O reaction rate is in agreement with most results in the literature at ∼ 10 8 K, with enhanced accuracy thanks to our innovative approach merging together ANC and THM. (paper)

  13. Radiosensitivity of Nicotiana protoplasts. Action on cell; cycle effects of low dose and fractionated irradiations; biological repair

    International Nuclear Information System (INIS)

    Magnien, E.

    1981-10-01

    Leaf protoplasts of Nicotiana plumbaginifolia and Nicotiana sylvestris demonstrate five main qualities: they can be maintained as haploid lines; they constitute starting populations with a remarkable cytological homogeneity; they show a transient initial lag-phase; they yield very high plating efficiencies and retain permanently a complete differentiation capacity; being derived of a cell wall, they appear well adapted for fusion experiments or enzymatic dosages. The resumption of mitotic activity was followed by cytophotometric measurements, labelling experiments, nuclear sizing and enzymatic assays. The action of 5 Gy gamma-ray irradiations delayed entrance in the S-phase, provoked an otherwise not verified dependency between transcription, translation and protein synthesis, increased nuclear volumes in the G2-phase, and slightly stimulated the activity of a repair enzyme. The plating efficiency was a sensitive end-point which allowed the evaluation of the biological effectiveness of low to medium radiation-doses after gamma-ray and fast neutron irradiations. The neutron dose-RBE relationship increased from 3 to 25 when the dose decreased from 5 Gy to 5 mGy. When fractionated into low single doses only, a neutron dose of 300 mGy markedly increased its biological effectiveness: this phenomenon could not be explained by cell progression, and necessitated additional hypotheses involving other mechanisms in the specific action of low radiation doses. Radiation-induced UDS was measured in presence of aphidicolin. A beta-like DNA-polymerase was shown to be definitely involved in nuclear repair synthesis [fr

  14. Enhanced low dose rate radiation effect test on typical bipolar devices

    International Nuclear Information System (INIS)

    Liu Minbo; Chen Wei; Yao Zhibin; He Baoping; Huang Shaoyan; Sheng Jiangkun; Xiao Zhigang; Wang Zujun

    2014-01-01

    Two types of bipolar transistors and nine types bipolar integrated circuit were selected in the irradiation experiment at different "6"0Co γ dose rate. The base current of bipolar transistor and input bias current of amplifier and comparator was measured, low dose enhance factor of test device was obtained. The results show that bipolar device have enhanced low dose rate sensitivity, enhancement factor of bipolar integrated circuit was bigger than that of transistor, and enhanced low dose rate sensitivity greatly varied with different structure and process of bipolar device. (authors)

  15. Secondary neutron doses received by patients of different ages during intracranial proton therapy treatments

    International Nuclear Information System (INIS)

    Sayah, R.

    2012-01-01

    Proton therapy is an advanced radiation therapy technique that allows delivering high doses to the tumor while saving the healthy surrounding tissues due to the protons' ballistic properties. However, secondary particles, especially neutrons, are created during protons' nuclear reactions in the beam-line and the treatment room components, as well as inside the patient. Those secondary neutrons lead to unwanted dose deposition to the healthy tissues located at distance from the target, which may increase the secondary cancer risks to the patients, especially the pediatric ones. The aim of this work was to calculate the neutron secondary doses received by patients of different ages treated at the Institut Curie-centre de Protontherapie d'Orsay (ICPO) for intracranial tumors, using a 178 MeV proton beam. The treatments are undertaken at the new ICPO room equipped with an IBA gantry. The treatment room and the beam-line components, as well as the proton source were modeled using the Monte Carlo code MCNPX. The obtained model was then validated by a series of comparisons between model calculations and experimental measurements. The comparisons concerned: a) depth and lateral proton dose distributions in a water phantom, b) neutron spectrometry at one position in the treatment room, c) ambient dose equivalents at different positions in the treatment room and d) secondary absorbed doses inside a physical anthropomorphic phantom. A general good agreement was found between calculations and measurements, thus our model was considered as validated. The University of Florida hybrid voxelized phantoms of different ages were introduced into the MCNPX validated model, and secondary neutron doses were calculated to many of these phantoms' organs. The calculated doses were found to decrease as the organ's distance to the treatment field increases and as the patient's age increases. The secondary doses received by a one year-old patient may be two times higher than the doses

  16. Neutron capture and fission cross section of Americium-243 in the energy range from 5 to 250 keV

    International Nuclear Information System (INIS)

    Wisshak, K.; Kaeppeler, F.

    1983-04-01

    The neutron capture and subthreshold fission cross section of 243 Am was measured in the energy range from 5 to 250 keV using 197 Au and 235 U as the respective standards. Neutrons were produced via the 7 Li(p,n) and the T(p,n) reaction with the Karlsruhe 3-MV pulsed Van de Graaff accelerator. Capture events were detected by two MoxonRae detectors with graphite and bismuthgraphite converters, respectively. Fission events were registered by a NE-213 liquid scintillator with pulse-shape discriminator equipment. Flight paths as short as 50-70 mm were used to obtain optimum signal-to-background ratio. After correction for the different efficiency of the individual converter materials the capture cross section could be determined with a total uncertainty of 3-6%. The respective values for the fission cross section are 8-12%. The results are compared to predictions of recent evaluations, which in some cases are severely discrepant. (orig.)

  17. Determination of the neutron energy and spatial distributions of the neutron beam from the TSR-II in the large beam shield

    International Nuclear Information System (INIS)

    Clifford, C.E.; Muckenthaler, F.J.

    1976-01-01

    The TSR-II reactor of the ORNL Tower Shielding Facility has recently been relocated within a new, fixed shield. A principal feature of the new shield is a beam port of considerably larger area than that of its predecessor. The usable neutron flux has thereby been increased by a factor of approximately 200. The bare beam neutron spectrum behind the new shield has been experimentally determined over the energy range from 0.8 to 16 MeV. A high level of fission product gamma ray background prevented measurement of bare beam spectra below 0.8 MeV, however neutron spectra in the energy range from 8 keV to 1.4 MeV were obtained for two simple, calculable shielding configurations. Also measured in the present work were weighted integral flux distributions and fast neutron dose rates

  18. Validation of dose planning calculations for boron neutron capture therapy using cylindrical and anthropomorphic phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Koivunoro, Hanna; Seppaelae, Tiina; Uusi-Simola, Jouni; Merimaa, Katja; Savolainen, Sauli [Department of Physics, POB 64, FI-00014 University of Helsinki (Finland); Kotiluoto, Petri; Seren, Tom; Auterinen, Iiro [VTT Technical Research Centre of Finland, Espoo, POB 1000, FI-02044 VTT (Finland); Kortesniemi, Mika, E-mail: hanna.koivunoro@helsinki.f [HUS Helsinki Medical Imaging Center, University of Helsinki, POB 340, FI-00029 HUS (Finland)

    2010-06-21

    In this paper, the accuracy of dose planning calculations for boron neutron capture therapy (BNCT) of brain and head and neck cancer was studied at the FiR 1 epithermal neutron beam. A cylindrical water phantom and an anthropomorphic head phantom were applied with two beam aperture-to-surface distances (ASD). The calculations using the simulation environment for radiation application (SERA) treatment planning system were compared to neutron activation measurements with Au and Mn foils, photon dose measurements with an ionization chamber and the reference simulations with the MCNP5 code. Photon dose calculations using SERA differ from the ionization chamber measurements by 2-13% (disagreement increased along the depth in the phantom), but are in agreement with the MCNP5 calculations within 2%. The {sup 55}Mn(n,{gamma}) and {sup 197}Au(n,{gamma}) reaction rates calculated using SERA agree within 10% and 8%, respectively, with the measurements and within 5% with the MCNP5 calculations at depths >0.5 cm from the phantom surface. The {sup 55}Mn(n,{gamma}) reaction rate represents the nitrogen and boron depth dose within 1%. Discrepancy in the SERA fast neutron dose calculation (of up to 37%) is corrected if the biased fast neutron dose calculation option is not applied. Reduced voxel cell size ({<=}0.5 cm) improves the SERA calculation accuracy on the phantom surface. Despite the slight overestimation of the epithermal neutrons and underestimation of the thermal neutrons in the beam model, neutron calculation accuracy with the SERA system is sufficient for reliable BNCT treatment planning with the two studied treatment distances. The discrepancy between measured and calculated photon dose remains unsatisfactorily high for depths >6 cm from the phantom surface. Increasing discrepancy along the phantom depth is expected to be caused by the inaccurately determined effective point of the ionization chamber.

  19. Detection of renal cell carcinoma using neutron time of flight spectroscopy

    International Nuclear Information System (INIS)

    Viana, Rodrigo S.; Yoriyaz, Helio; Lakshmanan, Manu N.; Agasthya, Greeshma A.; Kapadia, Anuj J.

    2013-01-01

    The diagnosis of renal cell carcinoma (RCC) is challenging because the symptoms accompanying it are not unique to the disease, and can therefore be misdiagnosed as other diseases. Due to this characteristic, detection of renal cancer is incidental most of time, occurring via abdominal radiographic examinations unrelated to the disease. Presently, biopsy, which is invasive and an unpleasant procedure for the patient, is the most commonly used technique to diagnose RCC. In this study, we demonstrate the application of a novel noninvasive technique for detecting and imaging RCC in vivo. The elemental composition of biological tissues including kidneys has been investigated using a new technique called Neutron Stimulated Emission Computed Tomography (NSECT). This technique is based on detecting the energy signature emitted by the stable isotopes of elements in the body, which are stimulated to emit gamma radiation via inelastic neutron scattering. Methods for improving detection sensitivity and reducing dose, such as time-of-flight neutron spectroscopy have been explored. MCNP5 simulations were used to model the NSECT scanning of the human kidney where the energy and time of arrival of gamma photons were recorded in an ideal detector placed around the human torso. A 5 MeV collimated neutron beam was used to irradiate the kidney containing an RCC lesion. The resulting spectra were resolved in 100 picosecond and 1 keV time and energy bins, respectively. The preliminary results demonstrate the ability to localize the lesion through neutron time of flight spectroscopy and generate a tomographic image at a low dose to the patient. (author)

  20. Neutron spectrometry measurements in iron

    International Nuclear Information System (INIS)

    Perlini, G.; Acerbis, S.; Carter, M.

    1988-01-01

    A compact structure was prepared for use in making measurements of neutron penetration in iron which could serve as reference data and as a check for computer codes. About 30 iron plates were put together giving a useful overall length of 130 cm. At various depths along the central axis of the iron block, measurements were made with liquid scintillator spectrometers and proton recoil proportional counters. The energy band explored was between 14 KeV and 10 MeV. Here we report the original spectra of the impulses and the neutron spectra found by the NE213 code based on the differential method and by unfolding with the SPEC4 code for liquid scintillation counters and proton recoil spectrometers, respectively. 12 figs., 60 tabs., 6 refs

  1. Study on Neutron Generation by Using Modified Prototype D-D Neutron Generator

    International Nuclear Information System (INIS)

    Kim, In-Jung; Kim, Suk-Kwon; Park, Chang-Su; Jung, Nam-Suk; Jung, Hwa-Dong; Chung, Kyoung-Jae; Hwang, Yong-Seok; Choi, H. D.

    2006-01-01

    The effects of Ti target thickness and deuteron beam energy on neutron generation in the modified prototype DD neutron generator were studied. Three kinds of Ti targets with the thickness of 10 μm, 40 μm and 1 mm were used. Deuteron beam energy was varied from 45 keV to 65 keV. The effects of target thickness and deuteron beam energy were evaluated for every set of experimental run and the results were discussed

  2. Clinical application of fast neutrons

    International Nuclear Information System (INIS)

    Battermann, J.J.

    1981-01-01

    The results of treatments and clinical experiments with neutrons (from a medical d+T neutron generator with an output of 10 12 neutrons per second) are reported and discussed. Data on RBE values are presented after single doses and multiple fractions of neutrons and 60 Co-gamma rays on pulmonary metastases. The results of pilot studies on head and neck tumours, brain tumours and pelvic tumours are discussed. The accuracy of the calculated dose is tested with some in-vivo experiments during neutron irradiation of the pelvis. Estimations of RBE values for tumour control, skin damage and intestinal damage after fractionated neutron therapy are dealt with and the results obtained in treatment of sarcomas are discussed. The preliminary results are given of some clinical trials in Amsterdam. Also some data from other centres are reviewed. From these data some remarks about the future of neutron therapy are made. (Auth.)

  3. Neutron radiation capture

    International Nuclear Information System (INIS)

    1986-01-01

    For all stable and experimentally studied radionuclides evaluated data are presented on cross sections of thermal neutrons, on resonance integrals and medium neutron cross sections with energy of 30 KeV. Refs, figs and tabs

  4. A new online detector for estimation of peripheral neutron equivalent dose in organ

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L., E-mail: leticia@us.es; Sanchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009, Spain and Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Lorenzoli, M.; Pola, A. [Departimento di Ingegneria Nuclear, Politecnico di Milano, Milano 20133 (Italy); Bedogni, R. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare (INFN), Frascati Roma 00044 (Italy); Terrón, J. A. [Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Sanchez-Nieto, B. [Instituto de Física, Pontificia Universidad Católica de Chile, Santiago 4880 (Chile); Expósito, M. R. [Departamento de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Lagares, J. I.; Sansaloni, F. [Centro de Investigaciones Energéticas y Medioambientales y Tecnológicas (CIEMAT), Madrid 28040 (Spain)

    2014-11-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  5. A new online detector for estimation of peripheral neutron equivalent dose in organ

    International Nuclear Information System (INIS)

    Irazola, L.; Sanchez-Doblado, F.; Lorenzoli, M.; Pola, A.; Bedogni, R.; Terrón, J. A.; Sanchez-Nieto, B.; Expósito, M. R.; Lagares, J. I.; Sansaloni, F.

    2014-01-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  6. Neutron spectra and dosimetric features of isotopic neutron sources: a review

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas, Zac. (Mexico); Martinez O, S. A., E-mail: fermineutron@yahoo.com [Universidad Pedagogica y Tecnologica de Colombia, Grupo de Fisica Nuclear Aplicada y Simulacion, Av. Central del Norte 39-115, 150003 Tunja, Boyaca (Colombia)

    2015-10-15

    A convenient way to produce neutrons is the isotopic neutron source, where the production is through (α, n), (γ, n), and spontaneous fission reactions. Isotopic neutron sources are small, easy to handle, and have a relative low cost. On the other hand the neutron yield is small and mostly of them produces neutrons with a wide energy distribution. In this work, a review is carried out about the the main features of {sup 24}NaBe, {sup 24}NaD{sub 2}O, {sup 116}InBe, {sup 140}LaBe, {sup 238}PuLi, {sup 239}PuBe, {sup 241}AmB, {sup 241}AmBe, {sup 241}AmF, {sup 241}AmLi, {sup 242}CmBe, {sup 210}PoBe, {sup 226}RaBe, {sup 252}Cf and {sup 252}Cf/D{sub 2}O isotopic neutron source. Also, using Monte Carlo methods, the neutron spectra in 31 energy groups, the neutron mean energy; the Ambient dose equivalent, the Personal dose equivalent and the Effective dose were calculated for these isotopic neutron sources. (Author)

  7. Chromosome aberration analysis in persons exposed to low-level radiation from the JCO criticality accident in Tokai-mura

    International Nuclear Information System (INIS)

    Sasaki, Masao S.; Hayata, Isamu; Kamada, Nanao; Kodama, Yoshiaki; Kodama, Seiji

    2001-01-01

    Chromosome aberrations were studied in peripheral blood lymphocytes of 43 persons who were exposed to low-level radiation of mixed neutrons and γ-rays resulting from the JCO criticality accident. When the age-adjusted frequencies of dicentric and ring chromosomes were compared with the dose calibration curve established in vitro for 60 Co γ-rays as a reference radiation, a significant correlation was observed between the chromosomally estimated doses and the documented doses evaluated by physical means. The regression coefficient of the chromosomal doses against the documented doses, 1.47±0.33, indicates that the relative biological effectiveness of fission neutrons at low doses is considerably higher than that currently adopted in the radiation protection standard. (author)

  8. Neutron and gamma-ray dose-rates from the Little Boy replica

    International Nuclear Information System (INIS)

    Plassmann, E.A.; Pederson, R.A.

    1984-01-01

    We report dose-rate information obtained at many locations in the near vicinity of, and at distances out to 0.64 km from, the Little Boy replica while it was operated as a critical assembly. The measurements were made with modified conventional dosimetry instruments that used an Anderson-Braun detector for neutrons and a Geiger-Mueller tube for gamma rays with suitable electronic modules to count particle-induced pulses. Thermoluminescent dosimetry methods provide corroborative data. Our analysis gives estimates of both neutron and gamma-ray relaxation lengths in air for comparison with earlier calculations. We also show the neutron-to-gamma-ray dose ratio as a function of distance from the replica. Current experiments and further data analysis will refine these results. 7 references, 8 figures

  9. Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain

    International Nuclear Information System (INIS)

    Seppaelae, Tiina; Auterinen, Iiro; Aschan, Carita; Seren, Tom; Benczik, Judit; Snellman, Marjatta; Huiskamp, Rene; Ramadan, Usama Abo; Kankaanranta, Leena; Joensuu, Heikki; Savolainen, Sauli

    2002-01-01

    Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the brain of dogs before starting the clinical trials. A dose planning procedure was developed and uncertainties of the epithermal neutron-induced doses were estimated. The accuracy of the method of computing physical doses was assessed by comparing with in vivo dosimetry. Individual radiation dose plans were computed using magnetic resonance images of the heads of 15 Beagle dogs and the computational model of the FiR 1 epithermal neutron beam. For in vivo dosimetry, the thermal neutron fluences were measured using Mn activation foils and the gamma-ray doses with MCP-7s type thermoluminescent detectors placed both on the skin surface of the head and in the oral cavity. The degree of uncertainty of the reference doses at the thermal neutron maximum was estimated using a dose-planning program. The estimated uncertainty (±1 standard deviation) in the total physical reference dose was ±8.9%. The calculated and the measured dose values agreed within the uncertainties at the point of beam entry. The conclusion is that the dose delivery to the tissue can be verified in a practical and reliable fashion by placing an activation dosimeter and a TL detector at the beam entry point on the skin surface with homogeneous tissues below. However, the point doses cannot be calculated correctly in the inhomogeneous area near air cavities of the head model with this type of dose-planning program. This calls for attention in dose planning in human clinical trials in the corresponding areas

  10. Neutron-photon mixed field dosimetry by TLD-700 glow curve analysis and its implementation in dose monitoring for Boron Neutron Capture Therapy (BNCT) treatments

    Energy Technology Data Exchange (ETDEWEB)

    Boggio, E. F.; Longhino, J. M. [Centro Atomico Bariloche, Departamento de Fisica de Reactores y Radiaciones / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina); Andres, P. A., E-mail: efboggio@cab.cnea.gov.ar [Centro Atomico Bariloche, Division Proteccion Radiologica / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina)

    2015-10-15

    BNCT is a cancerous cells selective, non-conventional radiotherapy modality to treat malignant tumors such as glioblastoma, melanoma and recurrent head and neck cancer. It consists of a two-step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope (Boron-10) with high slow neutron capture cross-section. In a second step, the patient is irradiated with neutrons, which are absorbed by the Boron-10 agent with the subsequently nuclear reaction B- 10(n,a)Li-7, thereby resulting in dose at cellular level due to the high-Let particles. The neutron fields suitable for BNCT are characterized by high neutron fluxes and low gamma dose. Determination of each component is not an easy task, especially when the volume of measurement is quite small or inaccessible for a miniature ionization chamber, for example. A method of measuring the photon and slow neutron dose(mainly by N-14 and B-10) from the glow curve (GC) analysis of a single {sup 7}LiF thermoluminescence detector is evaluated. This method was suggested by the group headed by Dr. Grazia Gambarini. The dosemeters used were TLD-600 ({sup 6}LiF:Mg,Ti with 95.6% {sup 6}Li) and TLD-700 ({sup 7}LiF:Mg,Ti with 99.9% {sup 7}LiF) from Harshaw. Photon dose measurement using the GC analysis method with TLD-700 in mixed fields requires the relation of the two main peaks of a TLD-600 GC shape obtained from an exposition to the same neutron field, and a photon calibrated GC with TLD-700. The requirements for slow neutron dose measurements are similar. In order to properly apply the GC analysis method at the Ra-6 Research Reactor BNCT facility, measurements were carried out in a standard water phantom, fully characterized on the BNCT beam by conventional techniques (activation detectors and paired ionization chambers technique). Next, the method was implemented in whole body dose monitoring of a patient undergoing a BNCT treatment, using a Bo MAb (Bottle Manikin Absorption) phantom

  11. Neutron dose rate analysis on HTGR-10 reactor using Monte Carlo code

    Science.gov (United States)

    Suwoto; Adrial, H.; Hamzah, A.; Zuhair; Bakhri, S.; Sunaryo, G. R.

    2018-02-01

    The HTGR-10 reactor is cylinder-shaped core fuelled with kernel TRISO coated fuel particles in the spherical pebble with helium cooling system. The outlet helium gas coolant temperature outputted from the reactor core is designed to 700 °C. One advantage HTGR type reactor is capable of co-generation, as an addition to generating electricity, the reactor was designed to produce heat at high temperature can be used for other processes. The spherical fuel pebble contains 8335 TRISO UO2 kernel coated particles with enrichment of 10% and 17% are dispersed in a graphite matrix. The main purpose of this study was to analysis the distribution of neutron dose rates generated from HTGR-10 reactors. The calculation and analysis result of neutron dose rate in the HTGR-10 reactor core was performed using Monte Carlo MCNP5v1.6 code. The problems of double heterogeneity in kernel fuel coated particles TRISO and spherical fuel pebble in the HTGR-10 core are modelled well with MCNP5v1.6 code. The neutron flux to dose conversion factors taken from the International Commission on Radiological Protection (ICRP-74) was used to determine the dose rate that passes through the active core, reflectors, core barrel, reactor pressure vessel (RPV) and a biological shield. The calculated results of neutron dose rate with MCNP5v1.6 code using a conversion factor of ICRP-74 (2009) for radiation workers in the radial direction on the outside of the RPV (radial position = 220 cm from the center of the patio HTGR-10) provides the respective value of 9.22E-4 μSv/h and 9.58E-4 μSv/h for enrichment 10% and 17%, respectively. The calculated values of neutron dose rates are compliant with BAPETEN Chairman’s Regulation Number 4 Year 2013 on Radiation Protection and Safety in Nuclear Energy Utilization which sets the limit value for the average effective dose for radiation workers 20 mSv/year or 10μSv/h. Thus the protection and safety for radiation workers to be safe from the radiation source has

  12. Neutron measurement in 12,13C+ 27Al system using CR-39 detectors and neutron rem meter

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Shanbhag, A.A.; Sunil, C.; Joshi, D.S.; Sarkar, P.K.

    2011-01-01

    In this work, neutron measurements carried out for the interaction of 60 and 67.5 MeV 12 C, 57.3 and 65 MeV 13 C ions with thick aluminium target by using CR-39 detectors and neutron rem meter is reported. Both the detector systems were irradiated at different angles viz. 0 deg, 30 deg, 60 deg, 90 deg with respect to the beam direction. The normalized track density measurements (tracks/cm 2 /projectile at 1m) in CR-39 detectors were correlated with the normalized dose equivalent values (μSv/projectile at 1m) obtained using the neutron rem meter. The track density was found to be more in case of 13 C than 12 C. However in all the cases, the track density per incident projectile was found to decrease as the angle with respect to beam direction increases, indicating non-isotropic nature of neutron emission. The ratio between measured dose equivalent in rem meter to the measured track densities in CR-39 detectors was found to be 2.8±0.2, which remains constant irrespective of the change in angle from beam direction as well as neutron spectrum, indicating a flat dose response of CR-39 detectors. (author)

  13. Further study of the glassy low-temperature properties of irradiated crystalline quartz: neutron and electron irradiation

    International Nuclear Information System (INIS)

    Laermans, C.; Daudin, B.

    1979-01-01

    Recently it has been shown that a quartz crystal after light fast neutron irradiation shows low temperature hypersonic properties which are similar to those found in glasses although the sample was still crystalline. Additional measurements have been carried out in the neutron-irradiated sample and a sample irradiated with high energy electrons has also been investigated. (Fast neutron dose 6 x 10 18 n/cm 2 , 2 MeV electron dose 3 x 10 19 e/cm 2 ). A magnetic field up to 1.5 T was found to have no influence in the hypersonic saturation behaviour of the neutron-irradiated sample (9 GHz, 1.65 K) and thermal conductivity measurements are consistent with a number of two level systems (2 LS) an order of magnitude lower than in vitreous silica as found before. Low temperature hypersonic measurements as a function of acoustic intensity and temperature as well as thermal conductivity measurements give no evidence for the presence of 2 LS in the electron irradiated sample. Considering the damage created in both samples this indicates that 2 LS are probably not related to point defects

  14. Using the Medipix3 detector for direct electron imaging in the range 60 keV to 200 keV in electron microscopy

    Science.gov (United States)

    Mir, J. A.; Plackett, R.; Shipsey, I.; dos Santos, J. M. F.

    2017-11-01

    Hybrid pixel sensor technology such as the Medipix3 represents a unique tool for electron imaging. We have investigated its performance as a direct imaging detector using a Transmission Electron Microscope (TEM) which incorporated a Medipix3 detector with a 300 μm thick silicon layer compromising of 256×256 pixels at 55 μm pixel pitch. We present results taken with the Medipix3 in Single Pixel Mode (SPM) with electron beam energies in the range, 60-200 keV . Measurements of the Modulation Transfer Function (MTF) and the Detective Quantum Efficiency (DQE) were investigated. At a given beam energy, the MTF data was acquired by deploying the established knife edge technique. Similarly, the experimental data required to determine DQE was obtained by acquiring a stack of images of a focused beam and of free space (flatfield) to determine the Noise Power Spectrum (NPS).

  15. A sensitivity study on neutron flux variation due to 10B concentration in dose calculation for BNCT

    International Nuclear Information System (INIS)

    Jung, Sang Hoon

    2006-02-01

    The effects of inclusion of 10 B concentration on neutron flux and dose in dose calculation were studied. In order to provide the quantitative effects of inclusion of 10 B concentrations on depressions of neutron and photon flux and dose, the fluxes and doses with voxel head phantoms for various 10 B concentrations homogeneously distributed were calculated by using MCNPX simulations. A lithium target system and beam shaping assembly, which have been developed at the Hanyang University, were used as epithermal neutron beam. The calculation results show that the neutron flux at the center of the head phantom decreases by approximately 5.4% per 10 ppm of 10 B concentration in comparison with the neutron flux in the case of boron-free. It was also observed that the tissue dose at the center of the head phantom is depressed by approximately 4.7% per 10 ppm of the 10 B concentration and the tumor dose by approximately 5.3% per 10 ppm. According to depth of tumors, it was observed that the depressions of the doses in the tumors are ranged in 3.7 ∼ 9.2%. The dose calculations in the case of boron-free show that it is overestimated in comparison with the dose calculations in the cases of the inclusion of 10 B concentrations for the normal tissue and the tumors. Therefore, in dose calculation for BNCT, the depressions of neutron flux and dose should be considered. The results in this study are available to setting up the depression ratios which can be used for converting neutron and gamma fluxes and doses in phantom with boron free into the fluxes and doses in phantom with inclusion of 10 B concentrations in treatment. It is expected that the depression ratios is practicable to dose evaluation for BNCT

  16. Neutron production and dose rate in the IFMIF/EVEDA LIPAc injector beam commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Keitaro, E-mail: kondo.keitaro@jaea.go.jp [Rokkasho Fusion Institute, Japan Atomic Energy Agency, Rokkasho-mura, Kamikita-gun, Aomori (Japan); Narita, Takahiro; Usami, Hiroki; Takahashi, Hiroki; Ochiai, Kentaro; Shinto, Katsuhiro; Kasugai, Atsushi [Rokkasho Fusion Institute, Japan Atomic Energy Agency, Rokkasho-mura, Kamikita-gun, Aomori (Japan); Okumura, Yoshikazu [IFMIF/EVEDA Project Team, Rokkasho-mura, Kamikita-gun, Aomori (Japan)

    2016-11-01

    Highlights: • A dedicated neutron production yield monitoring system for LIPAc has been developed. • The biological dose rate during operation of the LIPAc injector was analyzed. • The neutron streaming effect due to penetrations in the shielding wall was investigated. - Abstract: The construction of the Linear IFMIF Prototype Accelerator (LIPAc) is in progress in Rokkasho, Japan, and the deuteron beam commissioning of the injector began in July 2015. Due to the huge beam current of 125 mA, a large amount of d-D neutrons are produced in the commissioning. The neutron streaming effect through pipe penetrations and underground pits may dominate the radiation dose at the outside of the accelerator vault during the injector operation. In the present study the effective dose rate expected during the injector commissioning was analyzed by a Monte Carlo calculation and compared with the measured value. For the comparison it is necessary to know the total neutron production yield in the accelerator vault, thus a dedicated neutron production yield monitoring system was developed. The yield obtained was smaller than that previously reported in a literature by a factor of a few and seems to depend on some beam conditions. From the comparison it was proved that the calculation always provides a conservative estimate and the dose rates in places where occupational works can always access and the controlled area boundary are expected to be far less than the legal criteria throughout the injector commissioning.

  17. A set-up for measuring neutron cross sections and radiation multiplicity from neutron-nucleus interaction

    International Nuclear Information System (INIS)

    Georgiev, G.P.; Ermakov, V.A.; Grigor'ev, Yu.V.

    1988-01-01

    A multiplicity detector of the ''Romashka'' type has been used on the 500 m flight part of the IBR-30 pulsed reactor. The detector consists of 16 independent sections with NaJ(Tl) crystals with a total volume of 36 liters. The geometric efficiency of single-ray detection is ∼ 80%. The gamma-ray to neutron detection efficiency ratio is ≥600 for neutrons with energies below 200 keV. This detector allows one to perform neutron capture and fission cross section measurements and to study gamma-ray multiplicity and resonance selfabsorption effects in the 20 eV-200keV neutron energy range

  18. 238U neutron-induced fission cross section for incident neutron energies between 5 eV and 3.5 MeV

    International Nuclear Information System (INIS)

    Difilippo, F.C.; Perez, R.B.; de Saussure, G.; Olsen, D.K.; Ingle, R.W.

    1979-01-01

    A measurement of the 238 U neutron-induced fission cross section was performed at the ORELA Linac facility in the neutron energy range between 5 eV and 3.5 MeV. The favorable signal-to-background ratio and high resolution of this experiment resulted in the identificaion of 85 subthreshold fission resonances or clusters of resonances in the neutron energy region between 5 eV and 200 keV. The fission data below 100 keV are characteristic of a weak coupling situation between Class I and Class II levels. The structure of the fission levels at the 720 eV and 1210 eV fission clusters is discussed. There is an apparent enhancement of the fission cross section at the opening of the 2 + neutron inelastic channel in 238 U at 45 keV. An enhancement of the subthreshold fission cross section between 100 keV and 200 keV is tentatively interpreted in terms of the presence of a Class II, partially damped vibrational level. There is a marked structure in the fission cross section above 200 keV up to and including the plateau between 2 and 3.5 MeV. 11 figures and 6 tables

  19. Microdosimetric investigation of a fast neutron radiobiology facility utilising the d(4)-9Be reaction.

    Science.gov (United States)

    Waker, A J; Maughan, R L

    1986-11-01

    For fast neutron therapy and radiobiology beams, knowledge of the primary neutron spectrum is the most fundamental requirement for the definition of radiation quality. However, microdosimetric measurements in the form of single-event spectra not only complement the primary neutron spectrum as a statement of radiation quality but also provide a sensitive method of detecting changes in the radiation field in situations where it is no longer possible to have precise knowledge of the primary neutron spectrum, for example after collimator changes and in positions where the radiation field consists of a large scattered component. For the various collimator arrangements employed at the Gray Laboratory facility small perturbations of the radiation field are observed which can be related to a softening of the primary neutron spectrum with increasing field size of the collimator. Gamma fraction determinations are in very good agreement with measurements employing the dual chamber technique and also show small changes with collimator field size giving rise to gamma components ranging from 0.09 to 0.12, the higher values being measured for the larger field sizes. Quality changes represented by the shape of the measured event-size spectra and the derived microdosimetric parameters were greatest for off axis and phantom measurements. With increasing depth in water, yD was found to decrease from 47.3 keV micron-1 at 5 cm to 35.6 keV micron-1 at 15 cm depth, and the gamma fraction was found to increase from 0.23 to 0.40. Although there is no generally accepted and agreed method of relating microdosimetric information to biological effectiveness, the dual radiation theory in its original form (Kellerer and Rossi 1972) has been shown to be a very useful model for the assessment of the biological effectiveness of fast neutrons (Kellerer et al 1976). The microdosimetric parameter which is used in the dual radiation model is the dose mean specific energy corrected for saturation zeta

  20. Angular dependence of dose equivalent response of an albedo neutron dosimeter

    International Nuclear Information System (INIS)

    Torres, B.A.; Boswell, E.; Schwartz, R.B.

    1994-01-01

    The ANSI provides procedures for testing the performance of dosimetry services. Although neutron dose equivalent angular response studies are not now mandated, future standards may well require that such studies be performed. Current studies with an albedo dosimeter will yield information regarding the angular dependence of dose equivalent response for this type of personnel dosimeter. Preliminary data for bare 252 Cf fluences show a marked decrease in dosimeter reading with increasing angle. The response decreased by an approximate factor of four. For the horizontal orientation, the same response was noted from both positive and negative angles. However, for the vertical orientation, the response was unexplainably assymetric. We are also examining the response of the personnel badge in moderated 252 Cf fluences. Responses from the moderated and unmoderated 252 Cf fields and theoretical calculations of the neutron angular response will be compared. This information will assist in building a data base for future comparisons of neutron angular responses with other neutron albedo dosimeters and phantoms