WorldWideScience

Sample records for loolaid valve loolaid

  1. Valve Disease

    Science.gov (United States)

    ... heart valves, valve insufficiency, valve regurgitation, valve stenosis, valvular heart disease Every time your heart beats, blood flows into, ... removed from the market after being linked to heart valve disease. An infection in the lining of the heart's ...

  2. Valve's Way

    Directory of Open Access Journals (Sweden)

    Phanish Puranam

    2015-06-01

    Full Text Available What can we learn from outliers? While statisticians rightly warn us against their non-representativeness, we believe it is also true that thinking carefully about what makes them atypical may improve our understanding of the typical case. This is the premise behind the Organization Zoo series. Valve Corporation (Valve is an unusual firm. It is a rare example of a firm that appears to operate without any formal hierarchy in its organization. What can we learn about the viability of authority hierarchies from Valve’s way of organizing? We wrote a brief account of Valve based on public information sources and asked several renowned organizational experts to comment on this unusual firm. We asked them to write a short commentary on what the Valve example means for organizational theorists and practitioners. Thankfully, they all accepted, and we are excited to present the results of their thinking in this first “exhibit” in the Organization Zoo.

  3. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall...

  4. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  5. Excess flow shutoff valve

    Energy Technology Data Exchange (ETDEWEB)

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  6. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  7. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  8. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    Puranam and Håkonsson (2015) challenge us to ponder what we as organization design theorists make of Valve’s way (see also Jeppesen, 2008). We believe that Valve, in spite of its radical vision, does not represent a challenge to fundamental organization design theory and that it is questionable...

  9. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  10. Robotic mitral valve replacement.

    Science.gov (United States)

    Senay, Sahin; Gullu, Ahmet Umit; Kocyigit, Muharrem; Degirmencioglu, Aleks; Karabulut, Hasan; Alhan, Cem

    2014-01-01

    Robotic surgical techniques allow surgeons to perform mitral valve surgery. This procedure has gained acceptance, particularly for mitral valve repair in degenerative mitral disease. However, mitral repair may not always be possible, especially in severely calcified mitral valve of rheumatic origin. This study demonstrates the basic concepts and technique of robotic mitral valve replacement for valve pathologies that are not suitable for repair.

  11. Automatic shutoff valve

    Science.gov (United States)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  12. Adjustable safety relief valve

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, W.L.

    1990-06-12

    This patent describes a pressure relief valve having a relief set pressure. It comprises: a valve body having a fluid inlet and outlet, a spherical, metal valve seat associated with the inlet and a valve member comprising at least a portion of a spherical,metal ball attached to a ball holding element, the valve member being biased against the valve seat and thus providing a metal-to-metal seal preventing the passage of fluids past the valve seat when the fluid pressure in the inlet is below the relief pressure setting of the valve.

  13. Valve-in-valve-in-valve: Treating endocarditis of a transcatheter heart valve.

    Science.gov (United States)

    Nguyen, Caroline; Cheong, Adrian P; Himbert, Dominique

    2015-10-01

    Transcatheter heart valve endocarditis is a rare, but life threatening complication. We describe the case of a patient who was successfully treated by transcatheter aortic valve-in-valve-in-valve replacement with a favorable 1-year outcome, despite severe early complications.

  14. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  15. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  16. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  17. Valve-in-Valve Replacement Using a Sutureless Aortic Valve

    Science.gov (United States)

    Dohmen, Pascal M.; Lehmkuhl, Lukas; Borger, Michael A.; Misfeld, Martin; Mohr, Friedrich W.

    2016-01-01

    Patient: Female, 61 Final Diagnosis: Tissue degeneration Symptoms: Dyspnea Medication: — Clinical Procedure: Redo valve replacement Specialty: Surgery Objective: Rare disease Background: We present a unique case of a 61-year-old female patient with homograft deterioration after redo surgery for prosthetic valve endocarditis with root abscess. Case Report: The first operation was performed for type A dissection with root, arch, and elephant trunk replacement of the thoracic aorta. The present re-redo surgery was performed as valve-in-valve with a sutureless aortic biopros-thesis. The postoperative course was uneventful and the patient was discharged on day 6. Conclusions: The current case report demonstrates that sutureless bioprostheses are an attractive option for surgical valve-in-valve procedures, which can reduce morbidity and mortality. PMID:27694795

  18. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  19. Aortic Valve Regurgitation

    Science.gov (United States)

    ... inside your heart that involves heart valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a ... the United States — can damage the aortic valve. Rheumatic fever is still prevalent in developing countries but rare ...

  20. Pulmonary Valve Stenosis

    Science.gov (United States)

    ... growths called carcinoid tumors in the digestive system. Rheumatic fever. This complication of an infection caused by streptococcus ... valve stenosis later in life, including: Carcinoid syndrome Rheumatic fever Noonan's syndrome Mild to moderate pulmonary valve stenosis ...

  1. Aortic Valve Disease

    Science.gov (United States)

    ... Tricuspid Valve Disease Cardiac Rhythm Disturbances Thoracic Aortic Aneurysm Pediatric and Congenital Heart Disease Heart abnormalities that are ... Transplantation End-stage Lung Disease Adult Lung Transplantation Pediatric Lung ... Aortic Aneurysm Aortic Valve Disease Overview The human heart has ...

  2. Mitral Valve Stenosis

    Science.gov (United States)

    ... up around the ring around the mitral valve (annulus), which can occasionally cause mitral valve stenosis. Other ... the condition of your lungs. Transesophageal echocardiogram. A small transducer attached to the end of a tube ...

  3. Heart valve surgery

    Science.gov (United States)

    ... Tricuspid valve stenosis Risks The risks of having cardiac surgery include: Death Heart attack Heart failure Bleeding requiring ... and the A.D.A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Latest ...

  4. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  5. Aerodynamic Shutoff Valve

    Science.gov (United States)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  6. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  7. Dump valve assembly

    Science.gov (United States)

    Owen, T.J.

    1984-01-01

    A dump valve assembly comprising a body having a bore defined by a tapered wall and a truncated spherical valve member adapted to seat along a spherical surface portion thereof against said tapered wall. Means are provided for pivoting said valve member between a closed position engagable with said tapered wall and an open position disengaged therefrom.

  8. Quadricuspid Aortic Valve

    Directory of Open Access Journals (Sweden)

    Mehmet Taşar

    2013-03-01

    Full Text Available Quadricuspid aortic valve is an extremely rare congenital defect. Isolated form appears frequently. It is seen with aortic valve regurgitation in adulthood. This case report presents a rare clinical finding of an isolated quadricuspid aortic valve with aortic regurgitation in an 64-year-old female who was referred for cardiac evaluation due to newly identified murmur.

  9. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  10. Valve selection in aortic valve endocarditis

    Science.gov (United States)

    Zubrytska, Yana

    2016-01-01

    Aortic prosthetic valve endocarditis (PVE) is a potentially life-threatening disease. Mortality and incidence of infective endocarditis have been reduced in the past 30 years. Medical treatment of aortic PVE may be successful in patients who have a prompt response after antibiotic treatment and who do not have prosthetic dysfunction. In advanced stages, antibiotic therapy alone is insufficient to control the disease, and surgical intervention is necessary. Surgical treatment may be lifesaving, but it is still associated with considerable morbidity and mortality. The aim of surgery is to perform a radical excision of all infected and necrotic tissue, reconstruction of the left ventricle outflow tract, and replacement of the aortic valve. There is no unanimous consensus on which is the optimal prosthesis to implant in this context, and several surgical techniques have been suggested. We aim to analyze the efficacy of the surgical treatment and discuss the issue of valve selection in patients with aortic valve endocarditis.

  11. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2016-03-09

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  12. JenaValve.

    Science.gov (United States)

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  13. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  14. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves

    DEFF Research Database (Denmark)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann

    2017-01-01

    AIMS: Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, at smaller sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be frac...

  15. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  16. Mitral valve prolapse.

    Science.gov (United States)

    Gould, L; Gopalaswamy, C

    1984-05-01

    Mitral valve prolapse is a very common condition. It occurs in 4-5% of the population. It may be idiopathic or associated with a number of other conditions. Myxomatous degeneration is the underlying mechanism of mitral valve prolapse. Most patients with mitral valve prolapse have no symptoms. When symptoms do occur, palpitations, chest pain and dyspnea are the major complaints. The midsystolic click occasionally followed by the late systolic murmur are the typical physical findings. The echocardiogram plays a big role in the diagnosis of mitral valve prolapse. The beta blockers are used in the treatment of the symptomatic patient.

  17. Biological heart valves.

    Science.gov (United States)

    Ciubotaru, Anatol; Cebotari, Serghei; Tudorache, Igor; Beckmann, Erik; Hilfiker, Andres; Haverich, Axel

    2013-10-01

    Cardiac valvular pathologies are often caused by rheumatic fever in young adults, atherosclerosis in elderly patients, or by congenital malformation of the heart in children, in effect affecting almost all population ages. Almost 300,000 heart valve operations are performed worldwide annually. Tissue valve prostheses have certain advantages over mechanical valves such as biocompatibility, more physiological hemodynamics, and no need for life-long systemic anticoagulation. However, the major disadvantage of biological valves is related to their durability. Nevertheless, during the last decade, the number of patients undergoing biological, rather than mechanical, valve replacement has increased from half to more than three-quarters for biological implants. Continuous improvement in valve fabrication includes development of new models and shapes, novel methods of tissue treatment, and preservation and implantation techniques. These efforts are focused not only on the improvement of morbidity and mortality of the patients but also on the improvement of their quality of life. Heart valve tissue engineering aims to provide durable, "autologous" valve prostheses. These valves demonstrate adaptive growth, which may avoid the need of repeated operations in growing patients.

  18. A piezoelectrically actuated ball valve

    Science.gov (United States)

    Erwin, L. R.; Schwartz, H. W.; Teitelbaum, B. R.

    1972-01-01

    Bimorph strip composed of two layers of poled piezoelectric ceramic material closes and opens valve. Strip performs like capacitator, allowing initial inrush of current when valve is energized and then only small leakage current flows as valve remains energized.

  19. Mitral valve surgery - open

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Mitral Valve Prolapse Browse the Encyclopedia A.D. ...

  20. Blocked Urethral Valves

    Science.gov (United States)

    ... Blocked Urethral Valves Health Issues Listen Español Text Size Email Print Share Blocked Urethral Valves Page Content Article Body Urine leaves the bladder through a tube called the urethra, which in boys passes through the penis. Rarely, small membranes form across the urethra in ...

  1. Shutoff and throttling valve

    Science.gov (United States)

    Hays, L. G.

    1974-01-01

    Leaktight shutoff, precise flow control, and very low pressure drop are incorporated in all-metal valve designed for operation under extreme temperatures. Valve constructed with refractory metal is intended for control of high-temperature liquid cesium, but has applications related to control of high- and low-temperature liquids and gases.

  2. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering.

  3. Anticoagulation for Prosthetic Valves

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Kaneko

    2013-01-01

    Full Text Available Implantation of prosthetic valve requires consideration for anticoagulation. The current guideline recommends warfarin on all mechanical valves. Dabigatran is the new generation anticoagulation medication which is taken orally and does not require frequent monitoring. This drug is approved for treatment for atrial fibrillation and venous thromboembolism, but the latest large trial showed that this drug increases adverse events when used for mechanical valve anticoagulation. On-X valve is the new generation mechanical valve which is considered to require less anticoagulation due to its flow dynamics. The latest study showed that lower anticoagulation level lowers the incidence of bleeding, while the risk of thromboembolism and thrombosis remained the same. Anticoagulation poses dilemma in cases such as pregnancy and major bleeding event. During pregnancy, warfarin can be continued throughout pregnancy and switched to heparin derivative during 6–12 weeks and >36 weeks of gestation. Warfarin can be safely started after 1-2 weeks of discontinuation following major bleeding episode.

  4. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  5. Mesofluidic two stage digital valve

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  6. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    BACKGROUND AND AIMS OF THE STUDY: Prompted by anecdotal evidence and observations by surgeons, an investigation was undertaken into the potential differences in implanted aortic valve prosthesis sizes, during aortic valve replacement (AVR) procedures, between northern and southern European...... countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...

  7. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  8. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...... method that can be used to predict the performance of valves....

  9. A valve disk

    Energy Technology Data Exchange (ETDEWEB)

    Khayrullin, N.A.; Isayev, B.N.; Kruglov, S.A.; Molokanov, Yu.K.; Shchelkunov, V.A.; Shegay, V.R.; Vizhgorodskiy, B.N.

    1982-01-01

    A valve disk is proposed which includes a horizontal bed, on which there are laminar valves arranged in staggered order. To ensure the stable and effective operation of the disk in a broad range of loads by compensating for the direct flow and the partial sectioning of the disk bed, it is equipped with compensating elements installed in openings in the bed and hinged with it. They are made in the form of straight, triangular prisms with ports in the bases. The prisms are installed with the capability of movement relative to the disk bed. The valves are positioned on the upper lateral facets of the compensating elements.

  10. Surgical double valve replacement after transcatheter aortic valve implantation and interventional mitral valve repair.

    Science.gov (United States)

    Wendeborn, Jens; Donndorf, Peter; Westphal, Bernd; Steinhoff, Gustav

    2013-11-01

    Transcatheter aortic valve implantation, as well as interventional mitral valve repair, offer reasonable therapeutic options for high-risk surgical patients. We report a rare case of early post-interventional aortic valve prosthesis migration to the left ventricular outflow tract, with paravalvular leakage and causing severe mitral valve regurgitation. Initial successful interventional mitral valve repair using a clipped edge-to-edge technique revealed, in a subsequent procedure, the recurrence of mitral valve regurgitation leading to progressive heart failure and necessitating subsequent surgical aortic and mitral valve replacement.

  11. Mitral Valve Disease

    Science.gov (United States)

    ... for more information on procedures, news, and pre- & post-operative care. Section Navigation Select Topic Aortic Valve Disease ... is most commonly caused by inflammation from rheumatic fever, a disease that is related to strep infections; ...

  12. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  13. Pulmonary valve stenosis

    Science.gov (United States)

    ... valvuloplasty - pulmonary Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  14. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  15. Mitral Valve Prolapse

    Science.gov (United States)

    ... Kawasaki Disease Long Q-T Syndrome Marfan Syndrome Metabolic Syndrome Mitral Valve Prolapse Myocardial Bridge Myocarditis Obstructive Sleep Apnea Pericarditis Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden ...

  16. Implantation of the CoreValve percutaneous aortic valve.

    Science.gov (United States)

    Lamarche, Yoan; Cartier, Raymond; Denault, André Y; Basmadjian, Arsène; Berry, Colin; Laborde, Jean-Claude; Bonan, Raoul

    2007-01-01

    Surgical aortic valve replacement is the only recommended treatment for significant aortic valve stenosis. Percutaneous aortic valve replacement appears to be a novel option for high-risk patients. We report the implantation of the ReValving system (CoreValve, Paris, France) in a 64-year-old woman who was refused aortic valve replacement surgery for critical aortic stenosis and left ventricular dysfunction because of severe pulmonary fibrosis. After anesthesia, the patient was put on femorofemoral cardiopulmonary bypass, and underwent a balloon valvuloplasty with subsequent retrograde aortic valve replacement by the ReValving system. Transesophageal echocardiographic monitoring of the patient's hemodynamics showed immediate improvements of the valvular area and left ventricular ejection fraction and only traces of paravalvular leaks. The patient was easily weaned from ventilation and resumed activity soon after the surgery. A multidisciplinary approach is presently necessary to offer a reliable and safe procedure.

  17. [Technologies for cardiac valve prostheses].

    Science.gov (United States)

    Nakano, Kiyoharu

    2009-07-01

    To show the technological development of cardiac valve prostheses, a historical review of both mechanical and biological valve prostheses and a current overview of modern cardiac valve devices are provided. Scince the 1st implantation of Starr-Edwards ball valve in 1960, both mechanical and biological valve prostheses have advanced. The valve design, the material of the leaflet and the hausing of mechanical prostheses have improved. Currently, the majority of the mechanical prostheses are bileaflet tilting disc valves made of pyrolytic carbon, which is antithromboembolic. However, anticoagulation therapy with warfarin is still required. As for the bioprostheses, although the fixation and anti-mineralization methods of the tissues improved, the durability of these valves is still limited. For the material of the current biological valves, the porcine aortic valve or bovine pericardium are used. The tissues are fixed by non-pressure or low-pressure method in glutaraldehyde solution. A stented and non-stented valves are available. Epoch-making events in this field are the implantation of new bioprosthetic valves using tissue engineering methods and the development of the transcatheter valve replacement therapies.

  18. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen;

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry.......Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  19. Mitral Valve Aneurysm: A Rare Complication of Aortic Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    A Moaref

    2008-11-01

    Full Text Available A 20-year-old intravenous drug abuser man, refered to our hospital with dyspnea and orthopnea. Tranesophagealechocardiography revealed severe aortic regurgitation, healed vegetation of aortic valve and an aneurysm of theanterior leaflet of the mitral valve. The patient was discharged after aortic valve replacement and mitral valverepair.

  20. Research on Valve Body Design of Large Bore Sodium Valve

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Large bore sodium valve is one kind of key equipments of China Demonstration Fast Reactor (CDFR). It is installed in the pipeline before and behind SG units as a locking mechanism. Valve body which is used to bear pressure is the core of sodium valve design.

  1. Transcatheter Aortic Heart Valve Thrombosis

    DEFF Research Database (Denmark)

    Hansson, Nicolaj C; Grove, Erik L; Andersen, Henning R;

    2016-01-01

    BACKGROUND: There is increasing focus on transcatheter heart valve (THV) thrombosis. However, there are limited data on incidence, clinical implications and predisposing factors of THV thrombosis following transcatheter aortic valve replacement (TAVR). OBJECTIVES: We assessed the incidence...

  2. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  3. Nasal valve surgery.

    Science.gov (United States)

    Apaydin, Fazil

    2011-04-01

    Nasal obstruction can be due to internal and external valve problems that can be seen before and after rhinoplasty. The main scope of this article is to concentrate on surgical solutions to these problems. To overcome nasal obstruction at the internal valve, spreader grafts, spreader flaps, upper lateral splay graft, butterfly graft, flaring suture, M-plasty, Z-plasty, and suspension sutures have been described. The management of the external valve problems is possible by using lateral crural dissection and repositioning, lateral crural strut grafts, alar battens, lateral crural turn-in flap, alar rim grafts, and various other methods. It is not easy to decide which techniques would work best in every case. After a thorough examination and analysis, the underlying cause of the nasal obstruction can be understood, and one or multiple procedures can be chosen according to each individual problem.

  4. Percutaneous mitral valve repair.

    Science.gov (United States)

    Gillinov, A Marc; Liddicoat, John R

    2006-01-01

    Surgical mitral valve repair is the procedure of choice to treat mitral regurgitation of all etiologies. Whereas annuloplasty is the cornerstone of mitral valve repair, a variety of other surgical techniques are utilized to correct dysfunction of the leaflets and subvalvular apparatus; in most cases, surgical repair entails application of multiple repair techniques in each patient. Preclinical studies and early human experience have demonstrated that some of these surgical repair techniques can be performed using percutaneous approaches. Specifically, there has been great progress in the development of novel technology to facilitate percutaneous annuloplasty and percutaneous edge-to-edge repair. The objectives of this report were to (1) discuss the surgical foundations for these percutaneous approaches; (2) review device design and experimental and clinical results of percutaneous valve repair; and (3) address future directions, including the key challenges of patient selection and clinical trial design.

  5. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  6. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...... resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel....

  7. Pulsatile prosthetic valve flows.

    Science.gov (United States)

    Phillips, W M; Snyder, A; Alchas, P; Rosenberg, G; Pierce, W S

    1980-01-01

    The laser Doppler system has been established as a useful tool for eliciting the properties of simulated cardiovascular flows, and thus for comparative studies of flow properties of prosthetic valves. Significant differences among valve types and between models of one type have been documented. The complex variations of velocity profiles with time show that comparisons must be made for unsteady pulsatile rather than steady flow, despite the volume and complexity of the data required. Future studies will include methods of compacting the data presentation and improving the details of the experimental stimulation.

  8. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1990-12-31

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele`s pivot. The Schiele`s pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele`s pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele`s pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  9. Transcatheter Valve-in-Valve: A Cautionary Tale.

    Science.gov (United States)

    Luc, Jessica G Y; Shanks, Miriam; Tyrrell, Benjamin D; Welsh, Robert C; Butler, Craig R; Meyer, Steven R

    2016-09-01

    Transcatheter aortic valve replacement (TAVR) by valve-in-valve (VIV) implantation is an alternative treatment for high-risk patients with a degenerating aortic bioprosthesis. We present a case of transapical TAVR VIV with a 29-mm Edwards SAPIEN XT (ESV) (Edwards Lifesciences, Irvine, CA) into a 29-mm Medtronic Freestyle stentless bioprosthesis (Medtronic Inc, Minneapolis, MN) in which unanticipated dilatation of the Freestyle bioprosthesis resulted in intraprocedural embolization of the TAVR valve, necessitating urgent conversion to a conventional surgical aortic valve replacement (AVR). Our experience suggests that TAVR VIV with the 29-mm ESV in the setting of a degenerated 29-mm Freestyle stentless bioprosthesis must be undertaken with caution.

  10. Prosthetic valve thrombosis in a patient with mitral valve replacement.

    Science.gov (United States)

    Bilal, Muhammad; Khan, Muhammad Shahzeb; Haseeb, Abdul; Khan, Abdul Bari

    2015-07-01

    Prosthetic valve thrombosis within one year after mitral valve replacement is rarely seen in patients on warfarin therapy and without any risk factor. Here, we describe a case of a 39-year- old female, who presented with dyspnoea and shortness of breath 11 months after mitral valve replacement. The echocardiogram revealed severe valvular stenosis due to presence of clots on the mitral valve and restricted motion of the mitral leaflets. As a result of deterioration of general condition and haemodynamic un-stability, plan was made to re-operate for her valve replacement surgery. This case report highlights the diagnosis, prevention and management of patients with prosthetic valve thrombosis following mitral valve replacement.

  11. Distortion of the CoreValve during transcatheter aortic valve-in-valve implantation due to valve dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Souteyrand, Geraud, E-mail: gsouteyrand@chu-clermontferrand.fr [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Wilczek, Krzysztof [Department of Cardiology, Medical University of Silesia, Silesian Centre for Herat Diseases, Zabrze (Poland); Innorta, Andrea; Camilleri, Lionel [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Chodor, Piotr [Department of Cardiology, Medical University of Silesia, Silesian Centre for Herat Diseases, Zabrze (Poland); Lusson, Jean-René; Motreff, Pascal [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France); Laborde, Jean-Claude [St. George' s Hospital, London (United Kingdom); Chabrot, Pascal; Durel, Nicolas [Department of Cardiology, Gabriel Montpied Hospital, CHU Clermont-Ferrand, Clermont-Ferrand (France); ERIM-EA3295, University of Auvergne, Clermont-Ferrand (France)

    2013-09-15

    Nowadays transcatheter aortic valve implantation (TAVI) is an accepted alternative to surgical aortic valve replacement for high-risk patients (pts). Successful TAVI procedures for failed aortic surgical bioprosthesis (TAV-in-SAV) have already been reported. In the presented two cases of TAV-in-SAV implantation a strut distortion of the stent was revealed on angiographic imaging and confirmed on control CT scan. In both procedures, a dislocation of the medtronic core valve (MCV) prosthesis during implantation led to valve retrieval, with a necessity of reloading it in the 18F introducer before subsequent implantation of the same valve in correct position.

  12. An electrochemical active valve

    NARCIS (Netherlands)

    Neagu, C.R.; Gardeniers, J.G.E.; Elwenspoek, M.; Kelly, J.J.

    1997-01-01

    A novel electrochemical microactuator was developed, which operates as an active valve. The microactuator consists of an electrochemical cell and a membrane that deflects because of the pressure of oxygen gas generated by electrolysis. Relatively large pressures (up to tens of bars) can be reached w

  13. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Ansanelli, E.

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  14. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  15. Aortic valve surgery - open

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otton CM, Bowow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  16. Vent Relief Valve Test

    Science.gov (United States)

    2008-01-01

    Shown is the disassembly, examination, refurbishment and testing of the LH2 ( liquid hydrogen) and LOX (liquid oxygen) vent and relief valves for the S-IVB-211 engine stage in support of the Constellation/Ares project. This image is extracted from high definition video and is the highest resolution available.

  17. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  18. Measurement of reed valve kinematics

    Science.gov (United States)

    Fenkl, Michael; Dvořák, Václav; Vít, Tomáš

    2016-03-01

    The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  19. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Kalyani Nair; C V Muraleedharan; G S Bhuvaneshwar

    2003-06-01

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the performance of mechanical heart valves. The clinical performance of mechanical heart valves is also addressed. Efforts made in India in the development of mechanical heart valves are also discussed.

  20. Percutaneous tricuspid valve replacement in childhood

    Directory of Open Access Journals (Sweden)

    Mathias Emmel

    2015-01-01

    Full Text Available Percutaneous replacement of the tricuspid valve with a bovine jugular venous valve (melody valve was successfully undertaken in a 9-year-old boy. The patient had a previous history of bacterial endocarditis of the native tricuspid valve in infancy. Initially, a pericardial patch valve was created, followed by surgical replacement of the valve using a biological tissue valve at 4 years of age. Progressive stenosis and regurgitation of the biological valve, with severe venous congestion and resulting hepatic dysfunction prompted percutaneous valve replacement.

  1. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  2. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets fo...

  3. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  4. "Vanishing" pulmonary valve stenosis

    Directory of Open Access Journals (Sweden)

    Nofil I Arain

    2012-01-01

    Full Text Available Objective: Both spontaneous resolution and progression of mild pulmonary valve stenosis (PS have been reported. We reviewed characteristics of the pulmonary valve (PV to determine factors that could influence resolution of mild PS. Methods: Fifteen asymptomatic pediatric patients with spontaneous resolution of isolated mild PS were retrospectively reviewed. Results: There was no correlation between the PV gradient, clinical presentation, age at diagnosis, or PV morphology. The PV annulus was small at initial presentation, which normalized at follow up. When corrected for the body surface area (z-score, the PV annulus was normal in all patients, including at initial evaluation. Conclusions: Based on our observation, neither age at diagnosis, nor PV-morphology-influenced resolution of mild PS. The variable clinical presentation makes it difficult to categorize and observe mild PS by auscultation alone. The PV annulus z-score could be a useful adjunct to determine the course and serial observation of mild PS.

  5. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...

  6. Minimally Invasive Mitral Valve Replacement and Transfemoral Aortic Valve Implantation.

    Science.gov (United States)

    Rustenbach, Christian; Baumbach, Hardy; Hill, Stephan; Franke, Ulrich F W

    2015-01-01

    The case is reported of a symptomatic elderly patient with severe mitral regurgitation, severe aortic valve stenosis, and coronary heart disease. The coronary artery disease had been interventionally treated four years previously with stent implantation into the right coronary artery. Published studies have shown that a combination of mitral and aortic valve surgery is associated with a significantly increased risk of mortality and morbidity, particularly in elderly patients. In the present patient, both valvular malformations were successfully treated with a single-step interdisciplinary approach, namely an initial surgical mitral valve replacement followed by transfemoral transcatheter aortic valve replacement.

  7. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  8. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  9. Supramolecular spin valves

    Science.gov (United States)

    Urdampilleta, M.; Klyatskaya, S.; Cleuziou, J.-P.; Ruben, M.; Wernsdorfer, W.

    2011-07-01

    Magnetic molecules are potential building blocks for the design of spintronic devices. Moreover, molecular materials enable the combination of bottom-up processing techniques, for example with conventional top-down nanofabrication. The development of solid-state spintronic devices based on the giant magnetoresistance, tunnel magnetoresistance and spin-valve effects has revolutionized magnetic memory applications. Recently, a significant improvement of the spin-relaxation time has been observed in organic semiconductor tunnel junctions, single non-magnetic molecules coupled to magnetic electrodes have shown giant magnetoresistance and hybrid devices exploiting the quantum tunnelling properties of single-molecule magnets have been proposed. Herein, we present an original spin-valve device in which a non-magnetic molecular quantum dot, made of a single-walled carbon nanotube contacted with non-magnetic electrodes, is laterally coupled through supramolecular interactions to TbPc2 single-molecule magnets (Pc=phthalocyanine). Their localized magnetic moments lead to a magnetic field dependence of the electrical transport through the single-walled carbon nanotube, resulting in magnetoresistance ratios up to 300% at temperatures less than 1 K. We thus demonstrate the functionality of a supramolecular spin valve without magnetic leads. Our results open up prospects of new spintronic devices with quantum properties.

  10. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  11. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, John J. (Bingham County, ID)

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  12. Valve stem and packing assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wordin, J.J.

    1990-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  13. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  14. Mitral Valve Prolapse in Pregnancy

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Abstract Mitral valve prolapse is a benign condition. Mitral regurgitation is only complicated in patients with severe mitral valve prolapse. Women with mitral valve prolapse in the absence of other cardiovascular disorders tolerate pregnancy well and do not develop remarkable cardiac complications. Nevertheless, serious complications of mitral valve prolapse, including arrhythmia, infective endocarditis and cerebral ischemic events, can be present in pregnancy. Debates remain with regard to the use of prophylactic antibiotics and β-blockers in the pregnant women with mitral valve prolapse. The prognosis of the pregnant patients might be closely related to the pathological and (or functional changes of the mitral valve. Non-myxomatous mitral valve prolapse poses no or little obstetric risks in terms of pregnancy, labor and neonatal complications; whereas myxomatous mitral valve prolapse is a major etiology of valvular heart disease in women of childbearing age. In the pregnant patients with mitral valve prolapse progressing into major complications, surgical interventions are considered. Medicinal treatment of such patients with β-blockers should be a concern for the fetal safety.

  15. Innovative Stemless Valve Eliminates Emissions

    Science.gov (United States)

    2008-01-01

    Big Horn Valve Inc. (BHVI), of Sheridan, Wyoming, won a series of SBIR and Small Business Technology Transfer (STTR) contracts with Kennedy Space Center and Marshall Space Flight Center to explore and develop a revolutionary valve technology. BHVI developed a low-mass, high-efficiency, leak-proof cryogenic valve using composites and exotic metals, and had no stem-actuator, few moving parts, with an overall cylindrical shape. The valve has been installed at a methane coal gas field, and future applications are expected to include in-flight refueling of military aircraft, high-volume gas delivery systems, petroleum refining, and in the nuclear industry.

  16. Whitey Gauge and Root Valves (VPS)

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel: Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the Vacuum Pumping and Helium System.

  17. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    BACKGROUND: Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES: This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS...

  18. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    risk factors. METHODS AND RESULTS: Observational single-center study of 509 consecutive patients treated with a transcatheter implanted self-expandable aortic valve prosthesis (Medtronic CoreValve). We identified 18 patients diagnosed with TAVI-PVE during a median follow-up period of 1.4 years...

  19. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  20. Surge-damping vacuum valve

    Science.gov (United States)

    Bullock, Jack C.; Kelly, Benjamin E.

    1980-01-01

    A valve having a mechanism for damping out flow surges in a vacuum system which utilizes a slotted spring-loaded disk positioned adjacent the valve's vacuum port. Under flow surge conditions, the differential pressure forces the disk into sealing engagement with the vacuum port, thereby restricting the flow path to the slots in the disk damping out the flow surge.

  1. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Mitral Valve Prolapse Browse the Encyclopedia A.D. ...

  2. Valve-"Health"-Monitoring System

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2009-01-01

    A system that includes sensors and data acquisition, wireless data-communication, and data-processing subsystems has been developed as a means of both real-time and historical tracking of information indicative of deterioration in the mechanical integrity and performance of a highgeared ball valve or a linearly actuated valve that operates at a temperature between cryogenic and ambient.

  3. Combination throttle and shutoff valve

    Science.gov (United States)

    Carriker, J. W.

    1972-01-01

    Combination of translating sleeve throttle valve and conventional poppet valve provides capability of shutting off flow completely by poppet and sleeve control of the rate of flow. Integration of the two concepts can be accomplished without difficulty and in a manner that requires a minimum of development.

  4. Variable gas leak rate valve

    Energy Technology Data Exchange (ETDEWEB)

    Eernisse, Errol P. (Albuquerque, NM); Peterson, Gary D. (Albuquerque, NM)

    1976-01-01

    A variable gas leak rate valve which utilizes a poled piezoelectric element to control opening and closing of the valve. The gas flow may be around a cylindrical rod with a tubular piezoelectric member encircling the rod for seating thereagainst to block passage of gas and for reopening thereof upon application of suitable electrical fields.

  5. Fluid mechanics of artificial heart valves.

    Science.gov (United States)

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  6. Robotic mitral valve surgery.

    Science.gov (United States)

    Kypson, Alan P; Nifong, L Wiley; Chitwood, W Randolph

    2003-12-01

    A renaissance in cardiac surgery has begun. The early clinical experience with computer-enhanced telemanipulation systems outlines the limitations of this approach despite some procedural success. Technologic advancements, such as the use of nitinol U-clips (Coalescent Surgical Inc., Sunnyvale, CA) instead of sutures requiring manual knot tying, have been shown to decrease operative times significantly. It is expected that with further refinements and development of adjunct technologies, the technique of computer-enhanced endoscopic cardiac surgery will evolve and may prove to be beneficial for many patients. Robotic technology has provided benefits to cardiac surgery. With improved optics and instrumentation, incisions are smaller. The ergometric movements and simulated three-dimensional optics project hand-eye coordination for the surgeon. The placement of the wristlike articulations at the end of the instruments moves the pivoting action to the plane of the mitral annulus. This improves dexterity in tight spaces and allows for ambidextrous suture placement. Sutures can be placed more accurately because of tremor filtration and high-resolution video magnification. Furthermore, the robotic system may have potential as an educational tool. In the near future, surgical vision and training systems might be able to model most surgical procedures through immersive technology. Thus, a "flight simulator" concept emerges where surgeons may be able to practice and perform the operation without a patient. Already, effective curricula for training teams in robotic surgery exist. Nevertheless, certain constraints continue to limit the advancement to a totally endoscopic computer-enhanced mitral valve operation. The current size of the instruments, intrathoracic instrument collisions, and extrathoracic "elbow" conflicts still can limit dexterity. When smaller instruments are developed, these restraints may be resolved. Furthermore, a working port incision is still required for

  7. Valve-related complications after mechanical heart valve implantation.

    Science.gov (United States)

    Misawa, Yoshio

    2015-10-01

    The number of heart valve surgeries is increasing, and 19,164 patients underwent heart valve surgery in Japan in 2011. The early mortality rate has remained stable for more than 10 years. Many patients now survive for many years, with a reported 10-year survival rate of at least 60 %. However, unfavorable complications can occur after valve surgery. Valve-related complications include thromboembolisms, bleeding complications and prosthetic valve endocarditis, followed by structural and nonstructural prosthetic valve dysfunctions. Our review of studies published after 2000 revealed that the rate of all valve-related complications was 0.7-3.5 % per patient-year. Thromboembolisms occur at a rate of approximately 1 % per patient-year, and bleeding complications occur at almost 0.5 % per patient-year. Thromboembolic and hemorrhagic events related to anticoagulant therapy should be considered during life-long follow-up. The occurrence rate of endocarditis reaches 0.5 % per patient-year, with a poor postoperative survival. Structural dysfunctions have been largely overcome, and the nonstructural dysfunction rate is 0.4-1.2 % per patient-year. The nonstructural dysfunctions induced by paravalvular leaks and pannus ingrowth are also issues that need to be resolved.

  8. Patents and heart valve surgery - II: tissue valves.

    Science.gov (United States)

    Cheema, Faisal H; Kossar, Alexander P; Rehman, Atiq; Younas, Fahad; Polvani, Gianluca

    2013-08-01

    Valvular heart disease affects millions of Americans yearly and currently requires surgical intervention to repair or replace the defective valves. Through a close-knit collaboration between physicians, scientists and biomedical engineers, a vast degree of research and development has been aimed towards the optimization of prosthetic heart valves. Although various methods have made fantastic strides in producing durable prostheses, the therapeutic efficacy of prosthetic valves is inherently limited by a dependency upon lifelong anticoagulant regimens for recipients - a difficult challenge for many in clinical setting. Thus, biological tissue valves have been developed to circumvent vascular and immunemediated complications by incorporating biological materials to mimic native valves while still maintaining a necessary level of structural integrity. Over the past decade, a multitude of patents pertaining to the refinement of designs as well as the advancement in methodologies and technologies associated with biological tissue valves have been issued. This review seeks to chronicle and characterize such patents in an effort to track the past, present, and future progress as well as project the trajectory of tissue valves in the years to come.

  9. Self-Rupturing Hermetic Valve

    Science.gov (United States)

    Tucker, Curtis E., Jr.; Sherrit, Stewart

    2011-01-01

    For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self

  10. PWR safety and relief valve test program. Valve selection/juftification report. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1982-12-01

    NUREG 0578 required that full-scale testing be performed on pressurizer safety valves and relief valves representative of those in use or planned for use in PWR plants. To obtain valve performance data for the entire population of PWR plant valves, nine safety valves and ten relief valves were selected as a fully representative set of test valves. Justification that the selected valves represent all PWR plant valves was provided by each safety and relief valve manufacturer. Both the valve selection and justification work was performed as part of the PWR Safety and Relief Valve Test Program conducted by EPRI on behalf of the PWR utilities in response to the recommendations of NUREG 0578 and the requirements of the NRC. Results of the Safety and Relief Valve Selection and Justification effort is documented in this report.

  11. 42 CFR 84.137 - Inhalation and exhalation valves; check valves; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Inhalation and exhalation valves; check valves... PROTECTIVE DEVICES Supplied-Air Respirators § 84.137 Inhalation and exhalation valves; check valves; minimum requirements. (a) Inhalation and exhalation valves shall be provided where necessary and protected...

  12. 49 CFR 195.116 - Valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 195.116 Section 195.116 Transportation... PIPELINE Design Requirements § 195.116 Valves. Each valve installed in a pipeline system must comply with the following: (a) The valve must be of a sound engineering design. (b) Materials subject to...

  13. 14 CFR 125.133 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 125.133 Section 125.133....133 Fuel valves. Each fuel valve must— (a) Comply with § 125.155; (b) Have positive stops or suitable... operation or from accelerated flight conditions are not transmitted to the lines connected to the valve....

  14. 49 CFR 192.145 - Valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves. 192.145 Section 192.145 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.145 Valves. (a) Except for cast iron and plastic valves, each valve must meet the minimum requirements of API...

  15. 14 CFR 125.137 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 125.137 Section 125.137....137 Oil valves. (a) Each oil valve must— (1) Comply with § 125.155; (2) Have positive stops or... the valve. (b) The closing of an oil shutoff means must not prevent feathering the propeller,...

  16. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  17. Proportional valve with a piezoelectric actuator

    Science.gov (United States)

    Laski, Pawel Andrzej

    2016-11-01

    The article concerns a slotted proportional valve for use in pneumatic and hydraulic systems. There is a growing demand for both hydraulic and pneumatic ultrafast proportional valves. The conducted analysis of literature confirms the lack of such solutions for proportional valves. The currently used pneumatic systems for selection and segregation of parts and objects require ultrafast valves. The presented solution for the proportional valve can significantly improve and accelerate this type of technological processes. Furthermore, fast proportional valves can be successfully used for positional control of pneumatic and hydraulic drives. The article presents the design of a slotted divide valve and sets the maximum mass flow rate for service roads.

  18. Proportional valve with a piezoelectric actuator

    Directory of Open Access Journals (Sweden)

    Laski Pawel Andrzej

    2017-01-01

    Full Text Available The article concerns a slotted proportional valve for use in pneumatic and hydraulic systems. There is a growing demand for both hydraulic and pneumatic ultrafast proportional valves. The conducted analysis of literature confirms the lack of such solutions for proportional valves. The currently used pneumatic systems for selection and segregation of parts and objects require ultrafast valves. The presented solution for the proportional valve can significantly improve and accelerate this type of technological processes. Furthermore, fast proportional valves can be successfully used for positional control of pneumatic and hydraulic drives. The article presents the design of a slotted divide valve and sets the maximum mass flow rate for service roads.

  19. Double prosthetic aortic valve. Case report.

    Science.gov (United States)

    Liddicoat, J E; Bekassy, S M; De Bakey, M E

    1975-05-01

    A 55-year-old man underwent insection of a Hufnagel valve into his descending thoracic aorta for aortic valve insufficiency 18 years ago. He remained asymptomatic for 16 years. Because of progressive left ventricular failure his incompetent aortic valve was replaced with a De Bakey carbon ball aortic valve prosthesis 2 years later. Currently, 21 months after the operation, he is doing well with two aortic valves. Review of the literature suggests that he is the first patient reported with two aortic valves functioning concomitantly and one of the longest surviving patients with a Hufnagel valve.

  20. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  1. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  2. Human tissue valves in aortic position: determinants of reoperation and valve regurgitation

    NARCIS (Netherlands)

    T.P. Willems (Tineke); E.W. Steyerberg (Ewout); V.E. Kleyburg-Linkers; E. Bos (Egbert); L.A. van Herwerden (Lex); J.R.T.C. Roelandt (Jos); J.J.M. Takkenberg (Hanneke)

    2001-01-01

    textabstractBACKGROUND: Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve

  3. Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation

    NARCIS (Netherlands)

    J.P.A. Puvimanasinghe (John); M.B. Edwards; M.J.C. Eijkemans (René); E.W. Steyerberg (Ewout); L.A. van Herwerden (Lex); K.M. Taylor; G.L. Grunkemeier (Gary); J.D.F. Habbema (Dik); A.J.J.C. Bogers (Ad); J.J.M. Takkenberg (Hanneke)

    2004-01-01

    textabstractBACKGROUND: Mechanical valves and bioprostheses are widely used for aortic valve replacement. Though previous randomised studies indicate that there is no important difference in outcome after implantation with either type of valve, knowledge of outcomes after aortic va

  4. Simpler valve for reciprocating engines

    Science.gov (United States)

    Akkerman, J. W.

    1978-01-01

    Simpler design eliminating camshafts, cams, and mechanical springs should improve reliability of hydrazine powered reciprocating engines. Valve is expected to improve efficiency, and reduce weight of engines in range up to 50 horsepower.

  5. Titanium in engine valve systems

    Energy Technology Data Exchange (ETDEWEB)

    Allison, J.E.; Sherman, A.M.; Bapna, M.R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a two-to-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance.

  6. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... Kawasaki Disease Long Q-T Syndrome Marfan Syndrome Metabolic Syndrome Mitral Valve Prolapse Myocardial Bridge Myocarditis Obstructive Sleep Apnea Pericarditis Peripheral Vascular Disease Rheumatic Fever Sick Sinus Syndrome Silent Ischemia Stroke Sudden ...

  7. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... a heart attack or injury to the heart. Rheumatic Fever Untreated strep throat or other infections with strep bacteria that progress to rheumatic fever can cause heart valve disease. When the body ...

  8. CONGENITAL QUADRICUSPID AORTIC-VALVE

    NARCIS (Netherlands)

    BROUWER, MHJ; DEGRAAF, JJ; EBELS, T

    1993-01-01

    Two patients with a quadricuspid aortic valve are described, one of them with concomitant juxtaposed coronary orifices facing the right hand facing sinus. The etiology and incidence of this congenital anomaly will be discussed.

  9. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy....... The 30-day mortality rate for the 98 patients was zero, although 14 of the 98 mini-sternotomies had to be converted to complete sternotomies intraoperatively due to technical problems. Such conversion doubled the operative time over that of the planned full sternotomies. In the group of patients whose...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  10. The spin-valve transistor

    NARCIS (Netherlands)

    Monsma, Douwe Johannes

    1998-01-01

    High density magnetic recording, magnetic random access memories, displacement and current detection, contactless switching and electronic compass applications all require magnetic field sensors with unprecedented sensitivity. The spin-valve effect (giant magnetoresistance) found in 1988 in magnetic

  11. 57. Aortic valve replacement with sutureless valve and mitral valve repair in patient with infected aortic homograft

    Directory of Open Access Journals (Sweden)

    A. attia

    2016-07-01

    Full Text Available The approach of implanting aortic sutureless valve inside the calcific homograft is suitable in redo surgery especially if associated with mitral valve surgery. Aortic valve replacement in patients who have undergone previous aortic root replacement with an aortic homograft remains a technical challenge because of homograft degeneration and the need for a redo Bentall operation. We report a case of redo aortic valve replacement (valve in valve with a sutureless valve and mitral valve repair by miniband annuloplasty in a female patient aged 64 years old who underwent aortic valve replacement with homograft 14 years ago and presented by sever aortic valve regurge and sever mitral valve regurge because of infective endocarditis. This technique allows rapid aortic valve replacement in a heavily calcified aortic root. It also avoids aortic valve size affection after mitral valve repair by ordinary methods especially in patients with small aortic annulus. This technique is particularly suitable in redo procedures for homograft degeneration, it avoids performing a redo Bentall operation with its known problems as well as to avoid patient prosthesis mismatch.

  12. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  13. TCT-670 Optimal Transcatheter Heart Valve Sizing in Aortic Valve in Valve Implantation: Insights from the Valve in Valve International Data (VIVID) Registry

    DEFF Research Database (Denmark)

    Alnasser, Sami; Cheema, Asim N; Horlick, Eric

    2016-01-01

    Background: Optimal transcatheter heart valve (THV) sizing is crucial to optimize procedural outcomes. Larger THV oversizing is shown to decrease paravalvular leakage post transcatheter aortic valve replacement but its role in Valve in Valve implantation (ViV) is not well established. Methods...... group received a larger THV (25.5± 1.4 mm vs. 23.3 ± 1.0 mm, pimplantation, the oversized group achieved a larger EOA (1.54±0.4cm2 vs. 1.37± 0.5cm2, p...V implantation was associated with favorable post-implant EOA and gradient but a higher risk of aortic insufficiency and THV re-intervention. Further exploration within various THV and surgical valve types at different degree of THV oversizing is planned....

  14. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  15. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  16. Analysis of Complex Valve and Feed Systems

    Science.gov (United States)

    Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Cavallo, Peter; Dash, Sanford

    2007-01-01

    A numerical framework for analysis of complex valve systems supports testing of propulsive systems by simulating key valve and control system components in the test loop. In particular, it is designed to enhance the analysis capability in terms of identifying system transients and quantifying the valve response to these transients. This system has analysis capability for simulating valve motion in complex systems operating in diverse flow regimes ranging from compressible gases to cryogenic liquids. A key feature is the hybrid, unstructured framework with sub-models for grid movement and phase change including cryogenic cavitations. The multi-element unstructured framework offers improved predictions of valve performance characteristics under steady conditions for structurally complex valves such as pressure regulator valve. Unsteady simulations of valve motion using this computational approach have been carried out for various valves in operation at Stennis Space Center such as the split-body valve and the 10-in. (approx.25.4-cm) LOX (liquid oxygen) valve and the 4-in. (approx.10 cm) Y-pattern valve (liquid nitrogen). Such simulations make use of variable grid topologies, thereby permitting solution accuracy and resolving important flow physics in the seat region of the moving valve. An advantage to this software includes possible reduction in testing costs incurred due to disruptions relating to unexpected flow transients or functioning of valve/flow control systems. Prediction of the flow anomalies leading to system vibrations, flow resonance, and valve stall can help in valve scheduling and significantly reduce the need for activation tests. This framework has been evaluated for its ability to predict performance metrics like flow coefficient for cavitating venturis and valve coefficient curves, and could be a valuable tool in predicting and understanding anomalous behavior of system components at rocket propulsion testing and design sites.

  17. Titanium in Engine Valve Systems

    Science.gov (United States)

    Allison, J. E.; Sherman, A. M.; Bapna, M. R.

    1987-03-01

    Titanium alloys offer a unique combination of high strength-to-weight ratio, good corrosion resistance and favorable high temperature mechanical properties. Still, their relatively high cost has discouraged consideration for widespread use in automotive components. Recent demands for increased fuel economy have led to the consideration of these alloys for use as valve train materials where higher costs might be offset by improvements in performance and fuel economy. Lighter weight valve train components permit the use of lower spring loads, thus reducing friction and increasing fuel economy. Camshaft friction measurements made on a typical small displacement engine indicate that a twoto-four percent increase in fuel economy can be achieved. Valve train components are, however, subject to a severe operating environment, including elevated temperatures, sliding wear and high mechanical loads. This paper discusses the details of alloy and heat treatment selection for optimizing valve performance. When properly manufactured, titanium valves have been shown to withstand very stringent durability testing, indicating the technical feasibility of this approach to fuel economy improvement.

  18. Large Scale Magnetostrictive Valve Actuator

    Science.gov (United States)

    Richard, James A.; Holleman, Elizabeth; Eddleman, David

    2008-01-01

    Marshall Space Flight Center's Valves, Actuators and Ducts Design and Development Branch developed a large scale magnetostrictive valve actuator. The potential advantages of this technology are faster, more efficient valve actuators that consume less power and provide precise position control and deliver higher flow rates than conventional solenoid valves. Magnetostrictive materials change dimensions when a magnetic field is applied; this property is referred to as magnetostriction. Magnetostriction is caused by the alignment of the magnetic domains in the material s crystalline structure and the applied magnetic field lines. Typically, the material changes shape by elongating in the axial direction and constricting in the radial direction, resulting in no net change in volume. All hardware and testing is complete. This paper will discuss: the potential applications of the technology; overview of the as built actuator design; discuss problems that were uncovered during the development testing; review test data and evaluate weaknesses of the design; and discuss areas for improvement for future work. This actuator holds promises of a low power, high load, proportionally controlled actuator for valves requiring 440 to 1500 newtons load.

  19. 49 CFR 179.400-19 - Valves and gages.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Valves and gages. 179.400-19 Section 179.400-19...-19 Valves and gages. (a) Valves. Manually operated shut-off valves and control valves must be... liquid flow rates. All valves must be made from approved materials compatible with the lading and...

  20. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj;

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  1. Aortic valve replacement with the Nicks annulus enlargement procedure 12 years after mitral valve replacement.

    Science.gov (United States)

    Kazama, S; Kurata, A; Yamashita, Y

    1999-10-01

    An aortic valve replacement was successfully performed employing the Nicks annulus enlargement procedure in a case of aortic valve stenosis with small annulus 12 years after mitral valve replacement. Previous mitral valve replacement does not preclude feasibility of the Nicks procedure.

  2. Transapical transcatheter valve-in-valve replacement for deteriorated mitral valve bioprosthesis without radio-opaque indicators: the "invisible" mitral valve bioprosthesis.

    Science.gov (United States)

    Rossi, Marco Luciano; Barbaro, Cristina; Pagnotta, Paolo; Cappai, Antioco; Ornaghi, Diego; Belli, Guido; Presbitero, Patrizia

    2015-02-01

    In view of the high number of bioprosthetic valves implanted during the past 30 years, an increasing number of patients are coming to medical attention because of degenerated bioprostheses. Transcatheter aortic valve-in-valve implantation has been described as a less invasive alternative to re-operation to treat severe structural valve deterioration. As far as degenerated mitral valve bioprostheses are concerned, transcatheter transapical mitral valve-in-valve replacement (TMVR) has been less commonly performed, but may also become a viable alternative to re-do replacement surgery. We describe treatment of a degenerated bioprosthetic mitral valve, characterised by complete absence of any radio-opaque landmarks making the TMVR procedure very challenging.

  3. Percutaneous heart valves; past, present and future.

    Science.gov (United States)

    Rozeik, M M; Wheatley, D J; Gourlay, T

    2014-09-01

    Percutaneous heart valves provide a promising future for patients refused surgery on the grounds of significant technical challenges or high risk for complications. Since the first human intervention more than 10 years ago, over 50 different types of valves have been developed. The CoreValve and Edwards SAPIEN valves have both experienced clinical trials and the latter has gained FDA approval for implantation in patients considered inoperable. Current complications, such as major vascular bleeding and stroke, prevent these valves from being commonly deployed in patients considered operable in conventional surgery. This review focuses on the past and present achievements of these valves and highlights the design considerations required to progress development further. It is envisaged that, with continued improvement in valve design and with increased clinical and engineering experience, percutaneous heart valve replacement may one day be a viable option for lower-risk operable patients.

  4. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  5. Propellant isolation shutoff valve program

    Science.gov (United States)

    Merritt, F. L.

    1973-01-01

    An analysis and design effort directed to advancing the state-of-the-art of space storable isolation valves for control of flow of the propellants liquid fluorine/hydrazine and Flox/monomethylhydrazine is discussed. Emphasis is on achieving zero liquid leakage and capability of withstanding missions up to 10 years in interplanetary space. Included is a study of all-metal poppet sealing theory, an evaluation of candidate seal configurations, a valve actuator trade-off study and design description of a pneumo-thermally actuated soft metal poppet seal valve. The concepts and analysis leading to the soft seal approach are documented. A theoretical evaluation of seal leakage versus seal loading, related finishes and yield strengths of various materials is provided. Application of a confined soft aluminum seal loaded to 2 to 3 times yield strength is recommended. Use of either an electro-mechanical or pneumatic actuator appears to be feasible for the application.

  6. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  7. 2D SIMPLIFIED SERVO VALVE

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A novel pilot stage valve called simplified 2D valve, which utilizes both rotary and linear motions of a single spool, is presented.The rotary motion of the spool incorporating hydraulic resistance bridge, formed by a damper groove and a crescent overlap opening, is utilized as pilot to actuate linear motion of the spool.A criterion for stability is derived from the linear analysis of the valve.Special experiments are designed to acquire the mechanical stiffness, the pilot leakage and the step response.It is shown that the sectional size of the spiral groove affects the dynamic response and the stiffness contradictorily and is also very sensitive to the pilot leakage.Therefore, it is necessary to establish a balance between the static and dynamic characteristics in deciding the structural parameters.Nevertheless, it is possible to sustain the dynamic response at a fairly high level, while keeping the leakage of the pilot stage at an acceptable level.

  8. Transapical Mitral Valve-in-Valve Replacement in Patient With Previous Complex Sternal Reconstruction.

    Science.gov (United States)

    Hynes, Conor F; Fatemi, Omid; Sharma, Aditya C; Nagy, Christian D; Trachiotis, Gregory D

    2016-01-01

    We present a complex case of a transapical redo mitral valve-in-valve replacement. Repeat mitral valve replacement was indicated for severe symptomatic bioprosthetic stenosis. In addition to the patient's numerous comorbidities that included diabetes, hepatic cirrhosis, ischemic cardiomyopathy, and atrial flutter, he had undergone a previous open mitral valve replacement that was complicated by sternal dehiscence requiring extensive chest wall reconstruction. Transapical approach was performed through left minithoracotomy incision with balloon-expandable valve. Transapical valve-in-valve replacement of a stenotic mitral bioprosthesis is a viable solution in a patient with previous complex chest wall reconstruction and multiple comorbidities.

  9. Pregnancy-induced remodeling of heart valves.

    Science.gov (United States)

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves.

  10. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik;

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  11. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj;

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  12. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik;

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  13. Advantages with small control valves

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Gunnar

    2008-09-15

    Between 1995 and 2005, the Swedish District Heating Association carried out several research projects concerning small dimensions on control valves. This lecture aims at giving a summary of these findings which, if they are carried out, have a great impact on the district heating system. The outcome is advantages on both the production side and the customer side. Some of the project's conclusions are as follows: 1. The simulations show that the consequences of temperature disturbances can be reduced when applying smaller control valves, especially at low outdoor temperatures (-5 deg C). 2. The consequences of flow disturbances (pump stop) are not depending on the outdoor temperature (heat demand), but results over the whole year in reduced maximum flow during the process of operation recovery. With adequately reduced valve size, the resulting maximum flow at restart can be approximately reduced to the half, leading in reduced need of pumping peak power. 3. Similarly, the maximum peak power taken from the net at net recovery will be reduced, however, this effect is not as strong as that for flow. 4. Generally, we have found clear indications for that the adjustment of the K{sub vs}-values of control valves in substations should follow a certain logical order of priority. An important factor is the location of substations in respect to the production plant and to the pressure control points in the network. Another important factor is the absolute K{sub vs}-value of the over sizing, i.e. the difference of the actual installed valve and the targeted valve size. 5. Smaller size of control valves means also an improvement of the everyday operation of the district heating net, especially in the case when flow and power peaks are expected to occur. Examples for that could be the morning peaks with increase heat and hot water demands, or such events when the air temperature is decreasing very fast because of weather phenomena. Smaller control valves will smear out the

  14. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  15. Surface spin-valve effect.

    Science.gov (United States)

    Yanson, I K; Naidyuk, Yu G; Fisun, V V; Konovalenko, A; Balkashin, O P; Triputen, L Yu; Korenivski, V

    2007-04-01

    We report an observation of spin-valve-like hysteresis within a few atomic layers at a ferromagnetic interface. We use phonon spectroscopy of nanometer-sized point contacts as an in situ probe to study the mechanism of the effect. Distinctive energy phonon peaks for contacts with dissimilar nonmagnetic outer electrodes allow localizing the observed spin switching to the top or bottom interfaces for nanometer thin ferromagnetic layers. The mechanism consistent with our data is energetically distinct atomically thin surface spin layers that can form current- or field-driven surface spin-valves within a single ferromagnetic film.

  16. Whitey SCHE Gauge and Root Valves

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-11

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHa System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHa supply line.

  17. Pregnancy in women with prosthetic heart valves

    NARCIS (Netherlands)

    Pieper, P. G.; Balci, A.; Van Dijk, A. P.

    2008-01-01

    Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis mid death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than unfractionated and low-molecular-weight heparin, but carry the risk

  18. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  19. Whitey SCHE Gauge and Root Valves

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-03

    These valves are 1/2 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as isolation valves for pressure instrumentation in the SCHe System between the helium bottle supply manifolds and safety class helium pressure instrumentation, and in lower pressure SCHe supply line.

  20. Aerodynamic Characteristics of Tracheostomy Speaking Valves.

    Science.gov (United States)

    Fornataro-Clerici, Lisa; Zajac, David J.

    1993-01-01

    Pressure-flow characteristics were determined for four different one-way valves (Kisner, Montgomery, Olympic, and Passy-Muir) used for speech production in tracheotomy patients. Results indicated significant differences in resistance among the valves, with the resistance of one valve substantially greater than that of the normal upper airways.…

  1. 14 CFR 27.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 27.995 Section 27.995... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.995 Fuel valves. (a) There must be a positive, quick-acting valve to shut off fuel to each engine individually. (b) The control...

  2. 14 CFR 29.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 29.995 Section 29.995... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.995 Fuel valves. In addition to meeting the requirements of § 29.1189, each fuel valve must— (a) (b) Be supported so that no...

  3. 14 CFR 25.995 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves. 25.995 Section 25.995... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.995 Fuel valves. In addition to the requirements of § 25.1189 for shutoff means, each fuel valve must— (a) (b) Be supported...

  4. 14 CFR 29.1025 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil valves. 29.1025 Section 29.1025... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Oil System § 29.1025 Oil valves. (a) Each oil shutoff.... (c) Each oil valve must have positive stops or suitable index provisions in the “on” and...

  5. 14 CFR 25.1025 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Oil valves. 25.1025 Section 25.1025... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Oil System § 25.1025 Oil valves. (a) Each oil shutoff... feathering. (c) Each oil valve must have positive stops or suitable index provisions in the “on” and...

  6. 49 CFR 195.258 - Valves: General.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves: General. 195.258 Section 195.258... PIPELINE Construction § 195.258 Valves: General. (a) Each valve must be installed in a location that is accessible to authorized employees and that is protected from damage or tampering. (b) Each submerged...

  7. 14 CFR 121.239 - Oil valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil valve must— (1) Comply with § 121.257; (2) Have positive stops or suitable index provisions in the...

  8. 14 CFR 121.235 - Fuel valves.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 121.235 Section 121.235..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel valve must— (a) Comply with § 121.257; (b) Have positive stops or suitable index provisions in the...

  9. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ....109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a combined capacity to prevent an accumulation of pressure of more than five pounds per square inch above the... ends of the safety valve discharge lines shall be located or protected so that discharged steam...

  10. Aerodynamic Characteristics of Tracheostomy Speaking Valves.

    Science.gov (United States)

    Fornataro-Clerici, Lisa; Zajac, David J.

    1993-01-01

    Pressure-flow characteristics were determined for four different one-way valves (Kisner, Montgomery, Olympic, and Passy-Muir) used for speech production in tracheotomy patients. Results indicated significant differences in resistance among the valves, with the resistance of one valve substantially greater than that of the normal upper airways.…

  11. Flow and plate motion in compressor valves

    NARCIS (Netherlands)

    Habing, Reinder André

    2005-01-01

    The Basic Valve Theory is based on steady ow characteristics. Therefore unsteady ow conditions in the model valve have been considered in order to assess effects of unsteadiness on the performance of the Basic Valve Theory. The instantaneous gas force was predicted rather accurately by the theory. H

  12. Staphylococcus saprophyticus causing native valve endocarditis.

    Science.gov (United States)

    Garduño, Eugenio; Márquez, Irene; Beteta, Alicia; Said, Ibrahim; Blanco, Javier; Pineda, Tomás

    2005-01-01

    Coagulase negative staphylococci are a rare cause of native valve endocarditis. Staphylococcus saprophyticus is a coagulase-negative Staphylococcus infrequently reported as a human pathogen, and most of the cases reported are urinary tract infections. We describe a case of native valve endocarditis attributed to this organism. The patient needed valve replacement due to heart failure.

  13. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  14. The presence of fructosamine in human aortic valves is associated with valve stiffness.

    Science.gov (United States)

    Kishabongo, Antoine S; Katchunga, Philippe; Cikomola, Justin C; De Somer, Filip M; De Buyzere, Marc L; Speeckaert, Marijn M; Delanghe, Joris R

    2016-09-01

    Human heart valves are prone to glycation, a fundamental process of ageing. The aim of this study was to establish the relationship between fructosamine formation and the mechanical properties of human aortic valves. 67 patients (age: 76±8 years) diagnosed with an aortic valve stenosis, who underwent an aortic valve replacement were enrolled. Fructosamine and calcium concentrations in aortic valves were determined. Using a transthoracic Doppler echocardiography, aortic valve orifice area and transvalvular pressure gradients were measured. In a subgroup of 32 patients, the aortic valve orifice area was sufficient to carry out mechanical testing on a LFPlus Universal material tester. An in vitro removal of fructosamine of the valve was initiated using ATP-dependent fructosamine 3-kinase (FN3K). A significant correlation was found between the aortic valve fructosamine concentration and the calculated aortic valve orifice area: Y (aortic valve orifice area, mm(2))=1.050-0.228X (aortic valve fructosamine concentration, µmol/g valve) (r=-0.38). A significantly higher calcium concentration was measured in the aortic valves of diabetics in comparison with those of non-diabetics. A multiple regression analysis revealed that the presence of diabetes mellitus and aortic valve fructosamine concentration were the main predictors of the extensibility of the aortic valves. In the in vitro deglycation study, a significant lower aortic valve fructosamine concentration was detected after treatment with FN3K. This resulted in an increased flexibility of the aortic valves. Although no direct causativeness is proven with the presented results, which just show an association between fructosamine, the effect of FN3K and aortic valve stiffness, the present study points for the first time towards a possible additional role of the Amadori products in the biomechanical properties of ageing aortic valves. Published by the BMJ Publishing Group Limited. For permission to use (where not

  15. Pressure relief valve/safety relief valve testing

    Energy Technology Data Exchange (ETDEWEB)

    Murray, W.A.; Hamm, E.R.; Barber, J.R.

    1994-02-01

    Pressure vessels and piping systems are protected form overpressurization by pressure relief valves. These safety features are required to be tested-inspected on some periodic basis and, in most cases witnessed by a third party inspector. As a result nonconformances found by third parties Westinghouse Hanford Company initiated a task team to develop a pressure safety program. This paper reveals their findings.

  16. Aortic valve stenosis after previous coronary bypass: Transcatheter valve implantation or aortic valve replacement?

    Directory of Open Access Journals (Sweden)

    Jegaden Olivier

    2012-05-01

    Full Text Available Abstract We report a prospective comparison between transcatheter valve implantation (TAVI, n = 13 and surgical aortic valve replacement (AVR, n = 10 in patients with severe aortic valve stenosis and previous coronary bypass surgery (CABG. All patients had at least bilateral patent internal thoracic arteries bypass without indication of repeat revascularization. After a similar post-procedure outcome, despite one early death in TAVI group, the 1-year survival was 100% in surgical group and in transfemoral TAVI group, and 73% in transapical TAVI group. When previous CABG is the lone surgical risk factor, indications for a TAVI procedure have to be cautious, specially if transfemoral approach is not possible.

  17. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  18. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... Saunders; 2012:chap 61. Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Related MedlinePlus Health Topics Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  19. Microprocessor-Based Valved Controller

    Science.gov (United States)

    Norman, Arnold M., Jr.

    1987-01-01

    New controller simpler, more precise, and lighter than predecessors. Mass-flow controller compensates for changing supply pressure and temperature such as occurs when gas-supply tank becomes depleted. By periodically updating calculation of mass-flow rate, controller determines correct new position for valve and keeps mass-flow rate nearly constant.

  20. Rotary actuators for plastic valves

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, M. [Georg Fischer Piping Systems Ltd, Schaffhausen (Switzerland)

    2004-07-01

    Flexibility and modularity plus a high level of quality are the defining characteristics of this new generation of actuators from Georg Fischer. In conjunction with the new 546 ball valve, the PA 11/PA 21 pneumatic actuators and the EA 11/EA 21 electric actuators form an optimally co-ordinated system. (orig.)

  1. Mitral Valve Repair: The Chordae Tendineae

    Directory of Open Access Journals (Sweden)

    Carlos-A Mestres

    2015-10-01

    Full Text Available Repair of the mitral valve is the treatment of choice for mitral valve regurgitation when the anatomy is favorable. It is well known that mitral valve repair enjoys better clinical and functional results than any other type of valve substitute. This fact is beyond doubt regardless of the etiology of the valve lesion and is of particular importance in degenerative diseases.This review analyzes the most important advances in the knowledge of the anatomy, pathophysiology, and chordal function of the mitral valve as well as the different alternatives in the surgical repair and clinical results of the most prevalent diseases of the mitral valve. An attempt has been made to organize the acquired information available in a practical way.

  2. Transvalvular mitral regurgitation following mitral valve replacement a diagnostic dilemma

    OpenAIRE

    U S Dinesh Kumar; Umesh Nareppa; Shyam Prasad Shetty; Murugesh Wali

    2015-01-01

    After mitral valve replacement with a prosthetic valve, the valve should be competent and there should not be any residual prosthetic valve regurgitation. Transvalvular residual prosthetic valve regurgitation are difficult to diagnose and quantify. we are reporting interesting TEE images as a diagnostic dilemma in a case of transvalvular mitral regurgitation following mitral valve replacement secondary to entrapment of sub-valvular apparatus in a Chitra mechanical heart valve.

  3. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas;

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacement....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  4. Fault diagnosis of reciprocating compressor valve with the method integrating acoustic emission signal and simulated valve motion

    Science.gov (United States)

    Wang, Yuefei; Xue, Chuang; Jia, Xiaohan; Peng, Xueyuan

    2015-05-01

    This paper proposes a method of diagnosing faults in reciprocating compressor valves using the acoustic emission signal coupled with the simulated valve motion. The actual working condition of a valve can be obtained by analyzing the acoustic emission signal in the crank angle domain and the valve movement can be predicted by simulating the valve motion. The exact opening and closing locations of a normal valve, provided by the simulated valve motion, can be used as references for the valve fault diagnosis. The typical valve faults are diagnosed to validate the feasibility and accuracy of the proposed method. The experimental results indicate that this method can easily distinguish the normal valve, valve flutter and valve delayed closing conditions. The characteristic locations of the opening and closing of the suction and discharge valves can be clearly identified in the waveform of the acoustic emission signal and the simulated valve motion.

  5. Early Clinical Outcome of Mitral Valve Replacement Using a Newly Designed Stentless Mitral Valve for Failure of Initial Mitral Valve Repair.

    Science.gov (United States)

    Nishida, Hidefumi; Kasegawa, Hitoshi; Kin, Hajime; Takanashi, Shuichiro

    2016-12-21

    Here we report the early outcome of mitral valve replacement using a newly designed stentless mitral valve for failure of initial mitral valve repair. Mitral valve plasty (MVP) for mitral regurgitation is currently a standard technique performed worldwide. However, whether mitral valve repair should be performed for patients with advanced leaflet damage or complicated pathology remains controversial. Mitral valve replacement might be feasible for patients who have undergone failed initial MVP; however, it is not an optimal treatment because of poor valve durability and the need for anticoagulative therapy. We report two cases of successful mitral valve replacement using a newly designed stentless mitral valve made of fresh autologous pericardium, which may have a potential benefit over mitral valve repair or mitral valve replacement with a mechanical or bioprosthetic valve.

  6. A Kinematic Analysis of the Variable Valve Timing Mechanism with Three Elements and Continuous Valve Lift

    Directory of Open Access Journals (Sweden)

    Stelian Mihalcea

    2010-01-01

    Full Text Available An innovating solution for throttle-free load control for spark-ignition engines is Variable Valve Timing system (VVT System, or VVA - Variable Valve Actuation System. In this paper is presented an analytic method for kinematic analysis of the valve timing mechanism with three elements, which mainly includes the camshaft, the roller rocker finger and an intermediate rocker arm. This type of mechanism ensures a continuous valve lift (VVL System between two extreme valve heights. It is also presented the numerical example for the variable valve lift mechanism’s motion.

  7. Redoing a bioprosthetic tricuspid valve replacement with pacemaker wire through the ruined bioprosthetic valve orifice

    Institute of Scientific and Technical Information of China (English)

    GUO Hong-wei; PAN Shi-wei; SONG Yun-hu; HU Sheng-shou

    2011-01-01

    Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.

  8. Hydrodynamic Performance of the Medtronic CoreValve and the Edwards SAPIEN XT Transcatheter Heart Valve in Surgical Bioprostheses: An In Vitro Valve-in-Valve Model.

    Science.gov (United States)

    Sedaghat, Alexander; Sinning, Jan-Malte; Utzenrath, Marc; Ghalati, Pejman Farhadi; Schmitz, Christoph; Werner, Nikos; Nickenig, Georg; Grube, Eberhard; Ensminger, Stephan; Steinseifer, Ulrich; Kuetting, Maximilian

    2016-01-01

    Valve-in-valve transcatheter aortic valve replacement (TAVR) is becoming a valuable option with promising clinical results in failed bioprosthetic heart valves. Sizing recommendations are based on size compatibility rather than on broad clinical data, in vitro measurements, or biomechanical evidence. The hemodynamic performance of transcatheter heart valves within degenerated surgical heart valves is unknown. We evaluated the in vitro hydrodynamic performance of two commercially available transcatheter heart valves (Medtronic CoreValve [Medtronic, Minneapolis, MN] and Edwards SAPIEN XT [Edwards Lifesciences, Irvine, CA]) in two different bioprosthetic aortic valves (Edwards Perimount [Edwards Lifesciences] and St. Jude Trifecta [St. Jude Medical, St. Paul, MN]). Within the Edwards Perimount (23 mm) prosthesis, pressure gradients were higher for the SAPIEN XT compared with the CoreValve (11.2 ± 0.1 mm Hg versus 10.1 ± 0.1 mm Hg, p < 0.01), whereas effective orifice area (1.99 ± 0.01 cm(2) versus 1.80 ± 0.01 cm(2), p < 0.01) and total paravalvular leakage (9.0% ± 1.0% versus 5.4% ± 1.3%, p < 0.01) were increased when using the CoreValve. Similarly, measurements in the St. Jude Trifecta revealed higher transvalvular pressure gradients (13.0 ± 0.2 mm Hg versus 10.9 ± 0.3 mm Hg, p < 0.01) and lower effective orifice area for the SAPIEN XT compared with the CoreValve. However, total relative regurgitation was higher with SAPIEN XT as compared with the CoreValve in St. Jude Trifecta prostheses (11.2% ± 1.4% versus 8.3% ± 0.9%, p < 0.01). Both transcatheter heart valve prostheses performed well in the described valve-in-valve settings. Hydrodynamic results were in line with the International Organization for Standardization standards for all configurations. The observed differences indicate a necessity for preclinical valve-in-valve tests in addition to clinical long-term data about longevity. Copyright © 2016 The Society of Thoracic Surgeons. Published by

  9. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  10. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  11. 49 CFR 179.500-11 - Loading and unloading valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Loading and unloading valves. 179.500-11 Section...-113 and 107A) § 179.500-11 Loading and unloading valves. (a) Loading and unloading valve or valves shall be mounted on the cover or threaded into the marked end of tank. These valves shall be of...

  12. Segmented ball valve is easy to open and close

    Science.gov (United States)

    Prono, E.; Shinault, L. H.; Speisman, C.

    1966-01-01

    Segmented ball valve and flowmeter in the same spherical housing provide a valve that will handle large fluid volume without bulkiness and weight of blade valves or conventional ball valves. The valve is easily opened or closed and the flowmeter remains stationary, so errors are eliminated.

  13. Transesophageal echocardiography evaluation of tricuspid and pulmonic valves

    Directory of Open Access Journals (Sweden)

    Aneeta Bhatia

    2016-01-01

    Full Text Available The tricuspid is the lost valve and the pulmonary being the most anterior, is not visualized well on TEE; The Pulmonary valve is a semilunar valve that separates the right ventricle from the pulmonary artery. It is situated anterior and superior to the aortic valve, almost at right angle to the aortic valve and parallel to the beam of the ultrasound.

  14. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  15. [MINIMALLY INVASIVE AORTIC VALVE REPLACEMENT].

    Science.gov (United States)

    Tabata, Minoru

    2016-03-01

    Minimally invasive aortic valve replacement (MIAVR) is defined as aortic valve replacement avoiding full sternotomy. Common approaches include a partial sternotomy right thoracotomy, and a parasternal approach. MIAVR has been shown to have advantages over conventional AVR such as shorter length of stay and smaller amount of blood transfusion and better cosmesis. However, it is also known to have disadvantages such as longer cardiopulmonary bypass and aortic cross-clamp times and potential complications related to peripheral cannulation. Appropriate patient selection is very important. Since the procedure is more complex than conventional AVR, more intensive teamwork in the operating room is essential. Additionally, a team approach during postoperative management is critical to maximize the benefits of MIAVR.

  16. [Redo Aortic and Mitral Valve Replacement by Manouguian's Procedure for Active Prosthetic Valve Infection].

    Science.gov (United States)

    Kunitomo, Ryuji; Okamoto, Ken; Moriyama, Shuji; Sakaguchi, Hisashi; Tazume, Hirokazu; Yoshinaga, Takashi; Kawasuji, Michio

    2016-03-01

    The damage to the intervalvular fibrous trigone (IVFT) by infective endocarditis makes combined aortic and mitral valve replacement difficult. We performed Manouguian's double valve replacement for such a case and obtained a good result. A 81-year-old male underwent emergency operation due to active prosthetic valve endocarditis. He had a history of receiving combined aortic and mitral valve replacement because of active infective endocarditis at the age of 74 and redo aortic valve replacement 3 years after that. The infectious lesion extended from the mitral annulus to the IVFT and the aortic annulus, and it caused the prosthetic valve detachment from the aortic annulus. Manouguian's double valve replacement was required for radical resection and reconstruction of the IVFT. No recurrent infection or paravalvular leakage was observed during 49months follow up period. Manouguian's procedure is useful for complete resection of the infected IVFT and makes combined aortic and mitral valve replacement safer.

  17. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Hwan [Pusan National University, Busan (Korea, Republic of)

    2009-09-15

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  18. Percutaneous implantation of CoreValve aortic prostheses in patients with a mechanical mitral valve.

    Science.gov (United States)

    Bruschi, Giuseppe; De Marco, Federico; Oreglia, Jacopo; Colombo, Paola; Fratto, Pasquale; Lullo, Francesca; Paino, Roberto; Frigerio, Maria; Martinelli, Luigi; Klugmann, Silvio

    2009-11-01

    Concerns exist in the field of transcatheter aortic valve implantation regarding the treatment of patients with mechanical mitral valve for possible interference between the percutaneous aortic valve and the mechanical mitral prosthesis. We report our experience with percutaneous aortic valve implantation in 4 patients with severe aortic stenosis, previously operated on for mitral valve replacement with a mechanical prosthesis. All patients underwent uneventful percutaneous retrograde CoreValve implantation (CoreValve Inc, Irvine, CA). No deformation of the nitinol tubing of the prostheses (ie, neither distortion nor malfunction of the mechanical valve in the mitral position) occurred in any of the patients. All patients are alive and asymptomatic at a mean follow-up of 171 days.

  19. Imaging of Cardiac Valves by Computed Tomography

    Directory of Open Access Journals (Sweden)

    Gudrun Feuchtner

    2013-01-01

    Full Text Available This paper describes “how to” examine cardiac valves with computed tomography, the normal, diseased valves, and prosthetic valves. A review of current scientific literature is provided. Firstly, technical basics, “how to” perform and optimize a multislice CT scan and “how to” interpret valves on CT images are outlined. Then, diagnostic imaging of the entire spectrum of specific valvular disease by CT, including prosthetic heart valves, is highlighted. The last part gives a guide “how to” use CT for planning of transcatheter aortic valve implantation (TAVI, an emerging effective treatment option for patients with severe aortic stenosis. A special focus is placed on clinical applications of cardiac CT in the context of valvular disease.

  20. 3D Printed Multimaterial Microfluidic Valve

    Science.gov (United States)

    Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics. PMID:27525809

  1. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Steinbrüchel, Daniel Andreas; Ihlemann, Nikolaj

    2016-01-01

    BACKGROUND: The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize all-comers with severe native aortic valve stenosis to either transcatheter aortic valve replacement (TAVR) with the CoreValve self-expanding bioprosthesis or surgical aortic valve replacement (SAVR), inclu...... population. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01057173....

  2. STUDY ON FLUID THICKNESS BETWEEN POPPET AND VALVE GUIDE IN CONTROL VALVE OF INJECTOR

    Institute of Scientific and Technical Information of China (English)

    Zhang Jianming; Zhang Weigang; Wang Yawei

    2004-01-01

    The physical model of -20 diesel oil and force model of injector control valve of common rail system is built. The changes of the fluid thickness are investigated on the base of the results of CFD and experiments for control valve of injector. The results indicate that a fluid thickness of 0.02~0.03 mm between the poppet and valve guide is sufficient to dampen any excessive control valve poppet bouncing.

  3. An analysis of check valve performance characteristics based on valve design

    Energy Technology Data Exchange (ETDEWEB)

    McElhaney, K.L. [Oak Ridge National Lab., TN (United States). Engineering Technology Div.

    2000-04-01

    Although it had been theorized by nuclear industry valve experts that the two most significant factors in assessing check valve performance were valve type (or design) and operating conditions, until recently, no data was available to support their assumptions. In co-operation with the Nuclear Industry Check Valve Group (NIC), Oak Ridge National Laboratory (ORNL) undertook a review and analysis of check valve failures recorded in the Institute of Nuclear Power Operations' (INPO) Nuclear Plant Reliability Data System (NPRDS). This study involved the characterization of failures according to several parameters, including valve design (e.g. swing check, lift check). Since the valve design is not inherently included within the NPRDS engineering record for each component in the database, ORNL relied on input from NIC, valve manufacturers and catalogs to supply the missing information. As a result, nearly 60% of the 21000 check valves listed in the NPRDS component database and 85% of the 838 failures occurring during 1991-1992 were identified according to valve design. This data provided the basis to perform previously unavailable cross-correlations between parameters such as valve design versus failure mode, valve design versus failure discovery method, population/failure distributions by valve design, etc. Performance assessments and predictions based on more specific sets of parameters (as opposed to generic check valve failure rates obtained from standard reference sources that generally ignore the valve design) should result in a significant impact on future nuclear plant operations, including inservice testing (IST) practices, maintenance, and probabilistic risk assessments (PRAs) by providing a means to calculate more appropriate relative (and ultimately absolute) failure rates for check valves. (orig.)

  4. Improved valve and dash-pot assembly

    Science.gov (United States)

    Chang, S.C.

    1985-04-23

    A dash-pot valve comprises a cylinder submerged in the fluid of a housing and have a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with targentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  5. Valve and dash-pot assembly

    Science.gov (United States)

    Chang, Shih-Chih

    1986-01-01

    A dash-pot valve comprising a cylinder submerged in the fluid of a housing and having a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with tangentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  6. Check valve slam analysis in pumping station

    Science.gov (United States)

    Himr, D.; Habán, V.; Dokoupil, P.

    2016-03-01

    Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.

  7. Low-Pressure-Drop Shutoff Valve

    Science.gov (United States)

    Thornborrow, John

    1994-01-01

    Flapper valve remains open under normal flow conditions but closes upon sudden increases to high rate of flow and remains closed until reset. Valve is fluid/mechanical analog of electrical fuse or circuit breaker. Low-pressure-drop shutoff valve contains flapper machined from cylindrical surface. During normal flow conditions, flapper presents small cross section to flow. (Useful in stopping loss of fluid through leaks in cooling systems.)

  8. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  9. Bistable (latching) solenoid actuated propellant isolation valve

    Science.gov (United States)

    Wichmann, H.; Deboi, H. H.

    1979-01-01

    The design, fabrication, assembly and test of a development configuration bistable (latching) solenoid actuated propellant isolation valve suitable for the control hydrazine and liquid fluorine to an 800 pound thrust rocket engine is described. The valve features a balanced poppet, utilizing metal bellows, a hard poppet/seat interface and a flexure support system for the internal moving components. This support system eliminates sliding surfaces, thereby rendering the valve free of self generated particles.

  10. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  11. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  12. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve replacem

  13. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve replacem

  14. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  15. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area...

  16. Matching flow characteristics of standard shutoff valves eliminates need for custom fabricated valves

    Science.gov (United States)

    Bevan, A. F.

    1966-01-01

    Standard high pressure valves are used in low pressure fluid system testing when a substantial system pressure increase is required. The flow-vs-valve stroke is matched with that of the valves being replaced. Some correction to the plug contour may be necessary.

  17. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  18. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav;

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  19. Repositioning of an Intraventricular Dislocated Aortic Valve during Transcatheter Aortic Valve Implantation

    NARCIS (Netherlands)

    Natour, Ehsan; Douglas, Yvonne L.; Jainandunsing, Jayant S.; Schurer, Remco A. J.; van der Werf, Hendrik W.; van den Heuvel, Ad F. M.

    2014-01-01

    The case is presented of a 75-year-old man referred for transcatheter aortic valve implantation. During the procedure the prosthetic aortic valve became dislocated into the left ventricle shortly after expansion. The subsequent steps taken to reposition the valve using only materials at hand are des

  20. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...

  1. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  2. Improving the pneumatic control valve performance using a PID controller

    OpenAIRE

    Heidari, Mohammad; Homaei, Hadi

    2014-01-01

    Pneumatic control valves are still the most used in process industries due to their low cost and simplicity. This paper presents a design procedure of a PID controller for a pneumatic control valve. For comparison, P and PI controllers are also utilized for the control valve. The bond graph method is used to model the control valve, in order to compare the response characteristics of the valve. Simulation results are found for three controllers of the valve. The integral time absolute error c...

  3. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    Directory of Open Access Journals (Sweden)

    Abulon DJ

    2015-09-01

    Full Text Available Dina Joy Abulon,1 Martin Charles,2 Daniel E Charles21Global Medical Affairs, Alcon Laboratories, Inc., Lake Forest, CA, USA; 2Centro Oftalmológico Dr Charles, Buenos Aires, ArgentinaPurpose: To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP, fluid leakage, and vitreous incarceration during simulated vitrectomy.Methods: Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes.Results: In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005, and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05 and 27-gauge (P<0.05 non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas.Conclusion: Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy.Keywords: IOP, fluid leakage, vitreous incarceration

  4. Transaortic aortic valve replacement using the Edwards Sapien-XT Valve and the Medtronic CoreValve: initial experience.

    Science.gov (United States)

    Spargias, Konstantinos; Bouboulis, Nikolaos; Halapas, Antonios; Chrissoheris, Michael; Skardoutsos, Spyridon; Nikolaou, Joulia; Tsolakis, Apostolos; Mourmouris, Christos; Pattakos, Stratis

    2014-01-01

    Transcatheter aortic valve replacement (TAVR) is now an established treatment for certain patients with severe aortic valve stenosis (AS). However, as the number of patients screened for TAVR increases, many are found to have absolutely no option for peripheral artery access. Transaortic valve replacement (TAoVR) has been proposed as a new alternative route in patients deemed unsuitable for conventional approaches. We present our first series of TAoVR cases using the Edwards Sapien-XT and the Medtronic CoreValve prostheses. Twenty-five (25) symptomatic patients (mean age 78 ± 8 years, mean logistic EuroSCORE I 25 ± 11%) with severe AS underwent TAoVR using the Sapien-XT valve (10 patients) or the CoreValve (15 patients). The mean fluoroscopy time was 15.6 ± 4.2 minutes, the mean time in the intensive care unit was 1.9 ± 1.0 days, and the mean hospital stay was 6.4 ± 1.6 days. The mean effective aortic valve area increased (from 0.68 ± 0.15 cm(2) to 1.82 ± 0.34 cm(2), pMedtronic CoreValve prosthesis demonstrated that it could be performed safely, resulting in substantial acute echocardiographic and early clinical improvement.

  5. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  6. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm.

    Science.gov (United States)

    Tomsic, Anton; Li, Wilson W L; van Paridon, Marieke; Bindraban, Navin R; de Mol, Bas A J M

    2016-08-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred after the aneurysm perforated. The patient showed no signs of heart failure and completed a 6-week regimen of antibiotic therapy before undergoing successful aortic and mitral valve replacement. In addition to the patient's case, we review the relevant medical literature.

  7. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  8. Aortic and Mitral Valve Replacement Through a Single Transverse Aortotomy: A Useful Approach in Difficult Mitral Valve Exposure

    OpenAIRE

    Carmichael, Michael J.; Cooley, Denton A.; Favor, Arsenio S.

    1983-01-01

    Replacement of the mitral valve through a standard vertical left atriotomy in patients requiring both aortic and mitral valve replacement can be very difficult. This is especially true in patients who have undergone previous median sternotomy. Replacement of the mitral valve through the aortic root after excision of the aortic valve is described in two case reports. This is a convenient approach when traditional exposure of the mitral valve is impractical in patients requiring double valve re...

  9. Disruption of silicone valve housing in a Codman Hakim Precision valve with integrated Siphonguard.

    Science.gov (United States)

    Woerdeman, Peter A; Cochrane, David D

    2014-05-01

    Authors of this report describe 2 patients who had undergone shunt insertion for hydrocephalus and who, at 6 weeks or 9 months after their last revision, presented with symptoms of shunt dysfunction and CSF collections at the valve site. At the ensuing shunt revision in both patients, the silicone housing was fractured and the Siphonguard was disconnected from the Codman Hakim Precision flat-bottom valve. The cause of these failures was not clear since manipulation, bending, and twisting of the valves were not thought to have occurred during implantation. A review of the FDA's Manufacturer and User Facility Device Experience (MAUDE) database revealed 58 cases of silicone housing failure in the Codman Hakim Precision valve with integrated Siphonguard since the year 2000. A single report was found in the databases administered by the Canadian Medical Devices Sentinel Network (CMDSNet). The Codman Hakim Precision valves with integrated Siphonguard are delicate devices that do not withstand the intraoperative handling tolerated by other valves. When these valves are implanted, gentle handling and wide exposures are needed to minimize the risk of valve damage. Valves should be handled according to the manufacturer's instructions. However, in light of this particular pattern of failure, it is recommended that the manufacturer redesign this valve to provide handling tolerance that is characteristic of other valves on the market. The featured cases illustrate the importance of the surgeon's role in postmarket surveillance of medical devices and reporting device failures to the responsible agencies and manufacturers.

  10. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  11. Left atrial ball valve thrombus

    Directory of Open Access Journals (Sweden)

    R. Balaji

    2013-10-01

    Full Text Available "Ball valve thrombus" which is a spherical free floating clot in left atrium is an often quoted, but uncommonly encountered complication in patients with severe mitral stenosis of rheumatic origin, who are in atrial fibrillation. We describe the case of a 31-year-old lady with rheumatic heart disease, severe mitral stenosis and moderately severe aortic stenosis who had undergone closed mitral valvotomy 13 years ago. The patient presented with an episode of non-exertional syncope and breathlessness on exertion of 6 months duration and was in normal sinus rhythm. Echocardiography facilitated ante-mortem diagnosis and prompt institution of surgery was life saving.

  12. On-pump fibrillating heart mitral valve replacement with the SAPIEN™ XT transcatheter heart valve.

    Science.gov (United States)

    Ferrari, Enrico; Niclauss, Lars; Locca, Didier; Marcucci, Carlo

    2014-04-01

    In some high-risk patients, standard mitral valve replacement can represent a challenging procedure, requiring a risky extensive decalcification of the annulus. In particular, high-risk redo patients and patients with a previously implanted transcatheter aortic valve, who develop calcific mitral disease, would benefit from the development of new, minimally invasive, transcatheter or hybrid techniques for mitral valve replacement. In particular, mixing transcatheter valve therapies and well-established minimally invasive techniques for mitral replacement or repair can help in decreasing the surgical risk and the technical complexity. Thus, placing transcatheter, balloon-expandable Sapien™ XT stent-valves in calcified, degenerated mitral valves through a right thoracotomy, a left atriotomy and on an on-pump fibrillating heart, represents an attractive alternative to standard surgery in redo patients, in patients with concomitant transcatheter aortic stent-valves in place and in patients with a high-risk profile. We describe this hybrid technique in detail.

  13. Predictors of mortality after aortic valve replacement

    NARCIS (Netherlands)

    Tjang, Yanto Sandy; van Hees, Yvonne; Koerfer, Reiner; Grobbee, Diederick E.; van der Heijden, Geert J. M. G.

    Aortic valve replacement (AVR) is recommended as a standard surgical procedure for aortic valve disease. Still the evidence for commonly claimed predictors of post-AVR prognosis, in particular mortality, appears scant. This systematic review reports on the evidence for predictors of post-AVR

  14. Numerical Analysis of Large Diameter Butterfly Valve

    Science.gov (United States)

    Youngchul, Park; Xueguan, Song

    In this paper, a butterfly valve with the diameter of 1,800 mm was studied. Three-dimensional numerical technique by using commercial code CFX were conducted to observe the flow patterns and to measure flow coefficient, hydrodynamic torque coefficient and so on, when the large butterfly valve operated with various angles and uniform incoming velocity.

  15. 49 CFR 195.420 - Valve maintenance.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance. 195.420 Section 195.420 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... PIPELINE Operation and Maintenance § 195.420 Valve maintenance. (a) Each operator shall maintain each...

  16. A highly sensitive spin-valve transistor

    NARCIS (Netherlands)

    Erve, van 't O.M.J.; Vlutters, R.; Anil Kumar, P.S.; Kim, S.D.; Jansen, R.; Lodder, J.C.; Hadjipanayis, G.C.

    2001-01-01

    In this paper we present a spin-valve transistor made with a silicon on insulator wafer as emitter and a double sided polished Si wafer as collector. Using vacuum metal bonding we obtain a three terminal device in which a spin-valve layer is sandwiched between two Si wafers. We measure a 217% change

  17. Mitral valve repair in acquired dextrocardia.

    Science.gov (United States)

    Elmistekawy, Elsayed; Chan, Vincent; Hynes, Mark; Mesana, Thierry

    2015-10-01

    Surgical correction of valvular heart disease in patients with dextrocardia is extremely rare. We report a surgical case of mitral valve repair in a patient with acquired dextrocardia. Successful mitral valve repair was performed through a right lateral thoracotomy. We describe our surgical strategy and summarize the literature.

  18. Whole Teflon valves for handling droplets.

    Science.gov (United States)

    Cybulski, Olgierd; Jakiela, Slawomir; Garstecki, Piotr

    2016-06-21

    We propose and test a new whole-Teflon gate valve for handling droplets. The valve allows droplet plugs to pass through without disturbing them. This is possible due to the geometric design, the choice of material and lack of any pulses of flow generated by closing or opening the valve. The duct through the valve resembles a simple segment of tubing, without constrictions, change in lumen or side pockets. There are no extra sealing materials with different wettability or chemical resistance. The only material exposed to liquids is FEP Teflon, which is resistant to aggressive chemicals and fully biocompatible. The valve can be integrated into microfluidic systems: we demonstrate a complex system for culturing bacteria in hundreds of microliter droplet chemostats. The valve effectively isolates modules of the system to increase precision of operations on droplets. We verified that the valve allowed millions of droplet plugs to safely pass through, without any cross-contamination with bacteria between the droplets. The valve can be used in automating complex microfluidic systems for experiments in biochemistry, biology and organic chemistry.

  19. 46 CFR 64.67 - Shutoff valve.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Shutoff valve. 64.67 Section 64.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Pressure Relief Devices and Vacuum Relief Devices for MPTs § 64.67 Shutoff valve. A shutoff...

  20. Digital hydraulic valving system. [design and development

    Science.gov (United States)

    1973-01-01

    The design and development are reported of a digital hydraulic valving system that would accept direct digital inputs. Topics include: summary of contractual accomplishments, design and function description, valve parameters and calculations, conclusions, and recommendations. The electrical control circuit operating procedure is outlined in an appendix.

  1. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  2. Inexpensive tamper proof safety relief valve

    Science.gov (United States)

    Frankewich, P. A.

    1970-01-01

    Basic relief valve has added safety relief valve capability that relieves overpressure before failure can occur. It may be installed in inaccesible areas with a high degree of reliability, constructed from a variety of materials, and adapted to the user's specific application.

  3. Heart Valve Disease among Patients with Hyperprolactinaemia

    DEFF Research Database (Denmark)

    Steffensen, Charlotte; Maegbaek, Merete Lund; Laurberg, Peter;

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  4. Mitral valve disease—morphology and mechanisms

    Science.gov (United States)

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  5. Mitral valve disease--morphology and mechanisms.

    Science.gov (United States)

    Levine, Robert A; Hagége, Albert A; Judge, Daniel P; Padala, Muralidhar; Dal-Bianco, Jacob P; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H; Clusel, Catherine; Delling, Francesca N; Dietz, Harry C; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D; Jensen, Morten O; Jeunemaitre, Xavier P; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R; Mérot, Jean; Messas, Emmanuel; Milan, David P; Neri, Tui; Norris, Russell A; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A; Song, Jae-Kwan; Yacoub, Magdi H

    2015-12-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.

  6. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan;

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  7. Repair for acquired aortic valve disease.

    Science.gov (United States)

    Antunes, M J

    1996-10-01

    The favorable results of mitral valvuloplasty when compared with valve replacement have renewed the interest of many surgeons in aortic valve repair. However, these efforts have, for the most part, been unsuccessful. Also, the results of aortic valve replacement are usually better than those of mitral valve replacement. Yet, some patients appear to derive benefit from a conservative aortic valve procedure. The best examples are mild or moderate aortic valve disease associated with mitral valve or coronary artery disease, which constitute the primary indication for operation, where "prophylactic" aortic valve replacement does not appear justifiable. Other possible indications for aortic valvuloplasty includes patient's lack of compliance or contraindication to anticoagulation in young patients. Senile aortic stenosis, in very old patients with a small annulus, preserved leaflet morphology and nonsignificant commissural fusion should be considered for repair. However, since the procedure is not easily reproducible and the results not uniformly predictable, it cannot be recommended for generalized use. Nonetheless, experienced surgeons should be encouraged to continue these efforts.

  8. [Surgical Treatment of Prosthetic Valve Endocarditis].

    Science.gov (United States)

    Kaminishi, Yuichiro; Akutsu, Hirohiko; Sugaya, Akira; Kurumisawa, Soki; Takazawa, Ippei; Sato, Hirotaka; Muraoka, Arata; Aizawa, Kei; Ohki, Shinichi; Saito, Tsutomu; Kawahito, Koji; Misawa, Yoshio

    2015-11-01

    Between 2003 and 2014, at Jichi Medical University Hospital, 11 patients with prosthetic valve endocarditis (PVE) underwent re-operation. There was 1 in-hospital death and 2 late deaths. The cause of death was cirrhosis, heart failure and sepsis, respectively. Emergency surgery, previous double valve replacement (DVR) and Staphylococcus infection were common risk factors for all 3 cases. Two cases of patients that survived who underwent mitral valve replacement (MVR) and DVR for PVE after DVR were treated with multiple antibiotic courses for bacteremia associated with hemodialysis and colon cancer. One patient who underwent DVR after mitral valve plasty which was complicated with cerebral hemorrhage, had survived and was discharged. Of the aortic PVE patients, 2 cases of aortic valve replacement (AVR) using a mechanical valve, 1 case of aortic root replacement (ARR) using a mechanical valve, and 1 ARR using the homograft, were considered cured and never relapsed. A patient with aortic PVE, who underwent AVR after cesarean section for heart failure in birth period, has received ARR twice with the mechanical valve for recurrent pseudo-aneurysm of the left ventricular outflow tract. Since hemodialysis and colon cancer is a risk factor for recurrent PVE, it is necessary to consider the long-term administration of antibiotics after surgery.

  9. Transcatheter aortic valve replacement in elderly patients

    Institute of Scientific and Technical Information of China (English)

    Dimytri Siqueira; Alexandre Abizaid; Magaly Arrais J.; Eduardo Sousa

    2012-01-01

    Aortic stenosis is the most common native valve disease, affecting up to 5% of the elderly population. Surgical aortic valve replacement reduces symptoms and improves survival, and is the definitive therapy in patients with symptomatic severe aortic stenosis. However, despite the good results of classic surgery, risk is markedly increased in elderly patients with co-morbidities. Transcatheter aortic valve replacement (TAVR) allows implantation of a prosthetic heart valve within the diseased native aortic valve without the need for open heart surgery and cardiopulmonary bypass, offering a new therapeutic option to elderly patients considered at high surgical risk or with contraindications to surgery. To date, several multicenter registries and a randomized trial have confirmed the safety and efficacy of TAVR in those patients. In this chapter, we review the background and clinical applications of TAVR in elderly patients.

  10. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  11. [Interventional mitral valve replacement. Current status].

    Science.gov (United States)

    Lutter, G; Frank, D

    2016-02-01

    Approximately 30 % of patients suffering from severe valvular heart disease, such as mitral valve regurgitation are non-compliant to the gold standard of minimally invasive surgery, reconstruction or valve replacement. The number of these mostly old patients with severe comorbidities is increasing; therefore, transcatheter interventions have been developed to address an unmet clinical need and may be an alternative therapeutic option to the reference standard. Apart from the successful MitraClip therapy, alternative transcatheter reconstruction technologies are being developed. As with transcatheter aortic valve implantation (TAVI) procedures, the off-pump implantation of a valved stent into the mitral position mainly via a transapical approach will be of great benefit. Recently, the feasibility of transcatheter mitral valved stent implantation in high-risk patients has already been reported.

  12. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  13. Multidisciplinary optimization of a butterfly valve.

    Science.gov (United States)

    Song, Xue Guan; Wang, Lin; Baek, Seok Heum; Park, Young Chul

    2009-07-01

    A butterfly valve is a type of flow control device, typically used to regulate fluid flow. This paper proposes a new process to meet desired needs in valve design that is characterized by the complex configuration. First, the need is identified according to the valve user/company, and then the problem is defined with a characteristic function. Second, the initial model of valve is made, and then the initial analysis including fluid and/or structural analysis is carried out to predict the fluid and/or structural performance of the valve. Third, the optimization in the form of mathematical functions, which considers single or multiple objective and/or discipline, is handled. This part includes the design of computer experiment, approximation technique, topology optimization and sizing optimization. Finally, the validation experiment is conducted based on the optimum result to verify the accuracy of the optimization. An example is provided to confirm the availability of the process proposed here.

  14. Transcatheter mitral valve implantation via transapical approach

    DEFF Research Database (Denmark)

    Sondergaard, Lars; Brooks, Matthew; Ihlemann, Nikolaj;

    2015-01-01

    OBJECTIVES: As many as 50% of patients with severe symptomatic mitral valve regurgitation are denied surgical valve replacement or repair due to high operative risk. We describe an early series of cases of transcatheter implantation with a CardiAQ™ mitral valve via a transapical approach. METHODS......: Three consecutive patients with an Society of Thoracic Surgeons (STS) mortality score of >22% were selected for transcatheter mitral valve implantation (TMVI) on compassionate grounds. All patients were elderly, had severe mitral regurgitation (MR), were in Class IV heart failure and deemed unsuitable...... bypass surgery (n = 2), severe pulmonary hypertension (n = 1) and moderate to severe chronic renal failure (n = 3). A CardiAQ mitral valve was implanted using fluoroscopy and transoesophageal (TEE) guidance via a standard transapical approach. RESULTS: Accurate prosthesis positioning and deployment...

  15. Transcatheter aortic valve-in-valve implantation of a CoreValve in a degenerated aortic bioprosthesis.

    Science.gov (United States)

    Bruschi, Giuseppe; DeMarco, Federico; Oreglia, Jacopo; Colombo, Paola; Fratto, Pasquale; Lullo, Francesca; Paino, Roberto; Martinelli, Luigi; Klugmann, Silvio

    2010-03-01

    In recent years percutaneous aortic valve implantation has emerged as an alternative therapy to treat patients with symptomatic aortic stenosis considered to be high-risk surgical candidates. We report our experience of a percutaneous retrograde CoreValve implantation in a 77-year-old female with aortic bioprosthesis structural degeneration. The patient underwent aortic valve replacement for aortic stenosis in 1999 with the implantation of a 23 mm Carpentier-Edwards; her last echocardiography showed a severe bioprosthesis stenosis. After evaluation by cardiac surgeons and cardiologist, considering the high risk re-do surgical procedure (Logistic Euroscore 30%) and severe comorbidities (severe pulmonary hypertension, hepatocellular carcinoma and severe osteoporosis), a percutaneous aortic valve-in-valve replacement was preferred. A successful percutaneous 26 mm CoreValve prosthesis implantation was performed with the patient awake with local anesthesia and mild sedation. The patient was discharged after 10 days of hospitalization and she is in NYHA functional class I at follow-up. Our experience, characterized by a multidisciplinary approach, necessary to offer the safest conditions and care for patients, demonstrates the feasibility of a new, promising indication for the use of a transcatheter valve implantation: percutaneous treatment of a degenerated aortic bioprosthesis.

  16. Posttraumatic tricuspid valve injury and severe tricuspid valve regurgitation.

    Science.gov (United States)

    Gucuk Ipek, Esra

    2013-09-01

    A 66-year-old male was brought to our hospital following a car accident. He had subarachnoid hemorrhage, multiple rib fractures, and left hemopneumothorax. He was referred to the Cardiology Department for elevated troponin levels (42 ng/ml, reference 0-1 ng/ml). The electrocardiogram was free of ischemia, whereas the transthoracic echocardiography revealed dilated right heart chambers, enlarged tricuspid annulus and coaptation failure of the tricuspid valvular leaflets. There was rupture on the subvalvular apparatus of the anterior leaflet of the tricuspid valve with accompanying prolapse, causing severe tricuspid valvular regurgitation. The patient did not present right ventricular failure signs and symptoms; he was referred to surgery after the resolution of associated thoracic and cranial injuries.

  17. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  18. Whitey SCHe Ball Valves Provide Test Port Isolation

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They are used as normally closed isolation valves for test ports in the SCHe System between the gage root valve and the pressure indicator.

  19. 49 CFR 192.181 - Distribution line valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution line valves. 192.181 Section 192.181... line valves. (a) Each high-pressure distribution system must have valves spaced so as to reduce the time to shut down a section of main in an emergency. The valve spacing is determined by the...

  20. 46 CFR 105.25-20 - Shutoff valves required.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Shutoff valves required. 105.25-20 Section 105.25-20... Installed Below Decks § 105.25-20 Shutoff valves required. (a) Shutoff valves shall be provided in the suction lines as close to the tanks as possible. The valves shall be installed so as to shut off...

  1. 46 CFR 154.1125 - Pipes, fittings, and valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pipes, fittings, and valves. 154.1125 Section 154.1125... Firefighting § 154.1125 Pipes, fittings, and valves. (a) Each pipe, fitting, and valve for each water spray... listed in § 154.1110 must have at least one isolation valve at each branch connection and at least...

  2. 46 CFR 154.806 - Capacity of pressure relief valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Capacity of pressure relief valves. 154.806 Section 154... Equipment Cargo Vent Systems § 154.806 Capacity of pressure relief valves. Pressure relief valves for each... pressure above the set pressure of the relief valves: (a) The maximum capacity of an installed cargo...

  3. 46 CFR 78.17-5 - Valves and closing appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.17-5 Section 78.17-5..., Drills, and Inspections § 78.17-5 Valves and closing appliances. (a) It shall be the duty of the master to see that all valves, including cross connecting valves where fitted, and other appliances such...

  4. 46 CFR 153.368 - Pressure-vacuum valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve... relief valve must meet the requirements of Subpart 162.017 of this chapter....

  5. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Valves, fittings, and accessories. 98.25-40 Section 98... Anhydrous Ammonia in Bulk § 98.25-40 Valves, fittings, and accessories. (a) All valves, flanges, fittings... Engineering) of this chapter. Valves shall be fitted with noncorrosive material suitable for ammonia...

  6. 46 CFR 56.20-9 - Valve construction.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve construction. 56.20-9 Section 56.20-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Valves § 56.20-9 Valve construction. (a) Each valve must close with a right-hand...

  7. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  8. Heart Valve Biomechanics and Underlying Mechanobiology

    Science.gov (United States)

    Ayoub, Salma; Ferrari, Giovanni; Gorman, Robert C.; Gorman, Joseph H.; Schoen, Frederick J.; Sacks, Michael S.

    2017-01-01

    Heart valves control unidirectional blood flow within the heart during the cardiac cycle. They have a remarkable ability to withstand the demanding mechanical environment of the heart, achieving lifetime durability by processes involving the ongoing remodeling of the extracellular matrix. The focus of this review is on heart valve functional physiology, with insights into the link between disease-induced alterations in valve geometry, tissue stress, and the subsequent cell mechanobiological responses and tissue remodeling. We begin with an overview of the fundamentals of heart valve physiology and the characteristics and functions of valve interstitial cells (VICs). We then provide an overview of current experimental and computational approaches that connect VIC mechanobiological response to organ- and tissue-level deformations and improve our understanding of the underlying functional physiology of heart valves. We conclude with a summary of future trends and offer an outlook for the future of heart valve mechanobiology, specifically, multiscale modeling approaches, and the potential directions and possible challenges of research development. PMID:27783858

  9. Safety/relief-valve test program

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, J.A.

    1982-01-01

    In response to the NRC's Task 2.1.2 following the TMI-2 accident, government and industry programs were formulated to address the performance of safety and relief valve systems for pressurized and boiling water reactors. Objective is to demonstrate by testing and analysis that safety and relief valve systems in the reactor coolant system are qualified for the anticipated full range of reactor operating and accident conditions. The EPRI PWR program tested PWR safety valves and power operated relief valves (PORVs) under steam, liquid, and steam/liquid transition conditions. The program also tested PWR PORV block valves under steam conditions. The GE BWR program tested BWR relief and safety/relief valves under high pressure steam and low pressure liquid conditions. EG and G Idaho recent activities have focused on the evaluation of the industry test data, evaluation and modification of analytical codes for safety/relief valve system analysis, and initial evaluation of utility responses to US NRC program requirements.

  10. A multicentre comparative evaluation of catheter valves.

    Science.gov (United States)

    Fader, M; Pettersson, L; Brooks, R; Dean, G; Wells, M; Cottenden, A; Malone-Lee, J

    Catheter valves are an alternative to leg bags for urine drainage, but no studies have yet been published which have compared the performance of different valves. This study was undertaken to evaluate the performance of the seven catheter valves available on the UK market in April 1996. The study was carried out by the Continence Products Evaluation (CPE) Network funded by the Medical Devices Agency (Department of Health). Each valve type was tested for 1 week by 19-36 cognitively unimpaired and manually dextrous subjects recruited from 11 test centres. At the end of each week, subjects completed an evaluation form (based on a three-point rating scale) to record product performance. The same catheter valves were also tested for ease of opening/closing by 33 subjects (mostly catheter users) who had some manual impairment. Performance scores varied widely between products. It was found that, to be successful, a valve needs to be easy to manipulate, leak-free, comfortable and inconspicuous. Prescribers need to be aware of the strengths and limitations of different valves for appropriate product selection.

  11. Are valve repairs associated with better outcomes than replacements in patients with native active valve endocarditis?

    Science.gov (United States)

    Zhao, Dong; Zhang, Benqing

    2014-12-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether valve replacement was associated with higher morbidity and mortality rates than valve repair in patients with native active valve endocarditis. Altogether 662 papers were found using the reported search, of which 7 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Traditionally, valve replacement has been the standard therapy for valve endocarditis when surgical treatment is indicated. But now valve repair is increasingly used as an alternative, which may avoid disadvantages of anticoagulation, lower the risk of prosthetic infection and improve postoperative survival. To compare outcomes of these two treatments between studies can be difficult because most of related papers contain raw data on prosthetic valve endocarditis or healed endocarditis, which were excluded from our manuscript. Studies only analysing the outcomes of either of these treatments without the comparison of valve repair and replacement were also excluded. Finally, seven papers were identified. The American Heart Association/American College of Cardiology 2006 valvular guidelines recommended that mitral valve repair should be performed instead of replacement when at all possible. In three of the seven studies, there were significant differences between valve repair and replacement in long-term survival. One study found that aortic valve repair offered better outcomes in freedom from reoperation at 5 years (P = 0.021) and in survival at 4 years (repair vs replacement 88 vs 65%; P = 0.047). One study reported that there was improved event-free survival at 10 years in the mitral valve repair group (P = 0.015), although there was more previous septic embolization in this group. In one study, early and late mortality

  12. A novel implantable glaucoma valve using ferrofluid.

    Directory of Open Access Journals (Sweden)

    Eleftherios I Paschalis

    Full Text Available PURPOSE: To present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve. SETTING: Massachusetts Eye & Ear Infirmary, Boston, USA. METHODS: A glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmed™ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD analysis over a period of eight weeks. In vivo assessment was performed in three rabbits. RESULTS: In the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 µl/min at 12 mmHg; 4.3 µl/min at 16 mmHg; 7.6 µl/min at 21 mmHg. X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits. CONCLUSIONS: The proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway.

  13. Transcatheter Aortic Valve Replacement: A Review Article

    Directory of Open Access Journals (Sweden)

    Juan A Siordia

    2016-06-01

    Full Text Available Transcatheter aortic valve replacement (TAVR is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive procedure and reduce common complications, such as stroke. This review article focuses on the current data on the indications, risks, benefits, and future directions of TAVR. Recently, TAVR has been considered as a standard-of-care procedure. While this technique is used frequently in high-risk surgical candidates, studies have been focusing on the application of this method for younger patients with lower surgical risk. Moreover, several studies have proposed promising results regarding the use of valve-in-valve technique or the procedure in which the valve is placed within a previously implemented bioprosthetic valve. However, ischemic strokes and paravalvular leak remain a matter of debate in these surgeries. New methods and devices have been developed to reduce the incidence of post-procedural stroke. While the third generation of TAVR valves (i.e., Edwards Sapien 3 and Medtronic Evolut R addresses the issue of paravalvular leak structurally, results on their efficacy in reducing the risk of paravalvular leak are yet to be obtained. Furthermore, TAVR enters the field of hybrid methods in the treatment of cardiac issues via both surgical and catheter-based approaches. Finally, while TAVR is primarily performed on cases with aortic stenosis, new valves and methods have been proposed regarding the application of this technique in aortic regurgitation, as well as other aortic pathologies. TAVR is a suitable therapeutic approach for the treatment of aortic stenosis in high-risk patients. Considering the promising results in the current patient population

  14. Film edge nonlocal spin valves.

    Science.gov (United States)

    McCallum, Andrew T; Johnson, Mark

    2009-06-01

    Spintronics is a new paradigm for integrated digital electronics. Recently established as a niche for nonvolatile magnetic random access memory (MRAM), it offers new functionality while demonstrating low-power and high-speed performance. However, to reach high density spintronic technology must make a transition to the nanometer scale. Prototype devices are presently made using a planar geometry and have an area determined by the lithographic feature size, currently about 100 nm. Here we present a new nonplanar geometry in which one lateral dimension is given by a film thickness, on the order of 10 nm. With this new approach, cell sizes can shrink by an order of magnitude. The geometry is demonstrated with a nonlocal spin valve, where we study devices with an injector/detector separation much less than the spin diffusion length.

  15. Rotary Valve FY 2016 Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  16. Valve Corporation: Composing Internal Markets

    Directory of Open Access Journals (Sweden)

    Todd R. Zenger

    2015-07-01

    Full Text Available Discussions of the Valve Corporation are always enlightening. The skeptic wonders how much is rhetoric and recruiting ploy and how much is real. Is there clear evidence that this organizational design actually works – that it is efficient in this setting? While revenues per employee are quite remarkable, cause and effect are unclear. Is “boss-less-ness” the cause of high sales per employee or simply the result of high sales per employee, fueled from earlier success? The same question could be asked of Google’s unusual organizational approach. Is Google’s success the result of its extensive autonomy granted to employees, or is its past success the enabling cause of such autonomy? Such questions, of course, are empirically unanswerable here. I therefore set them aside and assume this organizational specimen is efficient – well-suited to its environment – and proceed with further commentary.

  17. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  18. Bacillus cereus endocarditis in native aortic valve.

    Science.gov (United States)

    Ngow, H A; Wan Khairina, W M N

    2013-02-01

    Bacillus cereus endocarditis is rare. It has been implicated in immunocompromised individuals, especially in intravenous drug users as well as in those with a cardiac prosthesis. The patient was a 31-year-old ex-intravenous drug addict with a past history of staphylococcal pulmonary valve endocarditis, who presented with symptoms of decompensated cardiac failure. Echocardiography showed severe aortic regurgitation with an oscillating vegetation seen on the right coronary cusp of the aortic valve. The blood cultures grew Bacillus cereus. We report this as a rare case of Bacillus cereus endocarditis affecting a native aortic valve.

  19. Infective endocarditis following transcatheter aortic valve replacement-

    DEFF Research Database (Denmark)

    Loh, Poay Huan; Bundgaard, Henning; S�ndergaard, Lars

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) can improve the symptoms and prognosis of patients with severe aortic stenosis who, due to a high expected operative risk, would not have otherwise been treated surgically. If these patients develop prosthetic valve endocarditis, their presentations may...... be atypical causing a delay in the diagnosis and treatment. The management is also complicated by their comorbidities, and surgical treatment may not be feasible leading to a significant morbidity and mortality. We describe a case of an 85-year-old man with TAVI prosthetic valve endocarditis successfully...

  20. The echocardiography of replacement heart valves

    Science.gov (United States)

    2016-01-01

    This is a practical description of how replacement valves are assessed using echocardiography. Normal transthoracic appearances including normal variants are described. The problem of differentiating normal function, patient–prosthesis mismatch and pathological obstruction in aortic replacement valves with high gradients is discussed. Obstruction and abnormal regurgitation is described for valves in the aortic, mitral and right-sided positions and when to use echocardiography in suspected infective endocarditis. The roles of transoesophageal and stress echocardiography are described and finally when other imaging techniques may be useful. PMID:27600454

  1. Combined pressure regulator and shutoff valve

    Science.gov (United States)

    Koch, E. F. (Inventor)

    1974-01-01

    A remotely operable pressure regulator and shutoff valve particularly suited for achieving high resolution and flow control, and positive shutoff is described. The valve is characterized by a spring-loaded ball coaxially aligned with a fluid port to be sealed, a spring-loaded pintle extended through the port into engagement with the ball, for controlling the position, a spring-loaded diaphragm for controlling the position of the pintle, and an axially displaceable spring supported by a movable stop which, in turn, is repositioned by a selectively operable stepper motor. Thus, the pressure-response characteristics for the valve can be varied through a selective repositioning of the stop.

  2. [New aspects in aortic valve disease].

    Science.gov (United States)

    Tornos, P

    2001-01-01

    Renewed interest for aortic valve disease has evolved in recent years. Aortic valve replacement has become the second most frequent cause of cardiac surgery, following coronary bypass surgery. In addition, the etiologic and physiopathologic knowledge of this disorder has improved. In the present paper we analyze three aspects of the disease which are, at present, the subject of study and controversy: first, we discuss the possible relationship between degenerative aortic stenosis and atherosclerosis; second, the involvement of the aortic root in cases of bicuspid aortic valve; and third, the surgical indications in asymptomatic patients with either aortic stenosis or regurgitation.

  3. Three-dimensional echocardiography in valve disease.

    Science.gov (United States)

    Colombo, Chiara; Tamborini, Gloria; Pepi, Mauro; Alimento, Marina; Fiorentini, Cesare

    2007-01-01

    This review covers the role of three-dimensional (3D) echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic) and quantitative advantages of this technique.

  4. Method and apparatus for monitoring motor operated valve motor output torque and power at valve seating

    Science.gov (United States)

    Casada, Donald A.

    1996-01-01

    A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization.

  5. Computational Fluid Dynamics Analysis of Butterfly Valve Performance Factors

    OpenAIRE

    Del Toro, Adam

    2012-01-01

    Butterfly valves are commonly used in industrial applications to control the internal flow of both compressible and incompressible fluids. A butterfly valve typically consists of a metal disc formed around a central shaft, which acts as its axis of rotation. As the valve's opening angle is increased from 0 degrees (fully closed) to 90 degrees (fully open), fluid is able to more readily flow past the valve. Characterizing a valve's performance factors, such as pressure drop, hydrodynamic torqu...

  6. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  7. Artificial SMA valve for treatment of urinary incontinence: upgrading of valve and introduction of transcutaneous transformer.

    Science.gov (United States)

    Tanaka, M; Hirano, K; Goto, H; Namima, T; Uchi, K; Jiang, Z W; Matsuki, H; Tanahashi, Y; Orikasa, S; Chonan, S

    1999-01-01

    This paper is concerned with the development of an artificial urethral valve driven by shape memory alloy actuators, which is attached onto the urethra of a urinary incontinence sufferer for treating the involuntary micturition. Three types of compact cylindrical valves are assembled and their opening and closing functions are examined experimentally. The updated valve is heated and opened by using the transcutaneous energy transformer consisting of a pair of flexible spiral-formed copper wire coils. The experiment using the canine urinary canal verifies that the total system of the valve and the transformer works well as an artificial sphictor muscle and controls the urinary flow through the canal appropriately.

  8. [Emergent transcatheter aortic valve implantation in a patient with bicuspid aortic valve stenosis in cardiogenic shock].

    Science.gov (United States)

    Pizzighini, S; Finet, G; Obadia, J-F; Revel, D; Bresson, D; Rioufol, G

    2015-02-01

    Transcatheter aortic valve implantation is a therapeutic option for high-risk patients with severe aortic valve stenosis and with cardiac symptoms. This procedure requires the preliminary evaluation by a "heart team" and presents some contraindications. We report the case of a 58-year-old man with severe bicuspid aortic valve stenosis and cardiogenic shock. In spite of contraindications and because of the failure of balloon aortic valvuloplasty, transcatheter aortic valve implantation was performed in emergency. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  9. In vitro evaluation of the iValve: a novel hands-free speech valve.

    Science.gov (United States)

    van der Houwen, Eduard B; van Kalkeren, Tjouwke A; Burgerhof, Johannes G M; van der Laan, Bernard F A M; Verkerke, Gijsbertus J

    2011-12-01

    We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.

  10. Experimental study on wear failure course of gas-valve/valve-seat in engine

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yun-cai; YAN Hang-zhi

    2005-01-01

    The wear failure course of gas-valve/valve-seat in engine was investigated with a simulating tester. The results show that the failure of the contact conical surface is mainly caused by the elastic and plastic deformation and the fatigue micro-crack and spalling. The creep-deformation and corrosion atmosphere accelerated wear failure course at the high temperature. The wear failure course of the gas-valve/valve-seat in engine follows general wear rules of mechanical elements, but the rate of wear in the sharp wear stage is faster.

  11. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    Science.gov (United States)

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  12. Mitral Valve Replacement with a Mechanical Valve for Severe Mitral Regurgitation in a Small Dog

    Directory of Open Access Journals (Sweden)

    Daisuke Taguchi

    2014-01-01

    Full Text Available A seven-year-old Shih Tzu with refractory repeated pulmonary edema and syncope was presented for surgical operation. From the results of cardiovascular examinations, the dog was diagnosed as severe mitral regurgitation (ACVIM consensus class D and mild tricuspid regurgitation. The dog first underwent surgery with mitral valve plasty; however, the results were unsatisfactory due to severe damage of the whole mitral valve. The operation was quickly changed to mitral valve replacement using a mechanical valve (19 mm. The dog survived surgery and lived for 2 years and one month after operation using long-term anticoagulant (warfarin therapy in spite of several thrombosis-related events.

  13. Basis of valve operator selection for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H. S.; Lee, D. J.; See, J. K.; Park, C. K.; Choi, B. S

    2000-05-01

    SMART, an integral reactor with enhanced safety and operability, is under development for use of the nuclear energy. The valve operator of SMART system were selected through the data survey and technical review of potential valve fabrication vendors, and it will provide the establishment and optimization of the basic system design of SMART. In order to establish and optimize the basic system design of SMART, the basis of selection for the valve operator type were provided based on the basic design requirements. The basis of valve operator selection for SMART will be used as a basic technical data for the SMART basic and detail design and a fundamental material for the new reactor development in the future.

  14. Valve Technology Arrangement of Cryopump: A Review

    Directory of Open Access Journals (Sweden)

    Sanjiv Y. Rajput

    2014-05-01

    Full Text Available A cryopump or a "cryogenic pump" is a vacuum pump that pumps the trap gases and vapours by condensing them on a cold surface. Helium gas which is very light can only be pumped by Cryopump. Cryopump cannot be used when working for continuous operation as it pumps the effluent till the saturation state is achieved. Then the absorbed gases are to be collected through other mechanical pump through regeneration process. Hence, valve technology arrangement is incorporated with the cryopump in order to achieve the continuous pumping when two cryopump are used in alternate processes (i.e. absorption and regeneration. Various design of Valve technology arrangement is proposed by different researcher all over the world. This review paper focuses on the different proposed valve technology arrangement and elaborately explains the various components of valve technology and concludes the best possible arrangement that can be used in Cryopump.

  15. Heritable retinoblastoma and accelerated aortic valve disease

    Science.gov (United States)

    Abeyratne, L R; Kingston, J E; Onadim, Z; Dubrey, S W

    2013-01-01

    Heritable retinoblastoma is associated with a germline mutation in the tumour suppressor gene RBI. The Rb protein (pRb) arises from the RB1 gene, which was the first demonstrated cancer susceptibility gene in humans. 1 Second primary malignancies are recognised complications of retinoblastoma. Furthermore, pRb is implicated in valve remodelling in calcific aortic valve disease. 2 3 We report a family with hereditary retinoblastoma and associated secondary primary malignancies. There are two interesting aspects to this family. The first is the concept of ‘cancer susceptibility genes’; the RBI gene being the first reported in humans. A further feature of note is that two family members also have bicuspid aortic valves. We discuss a potential association between the gene defect responsible for retinoblastoma (with its associated propensity for further malignancies) and accelerated deterioration of the bicuspid aortic valve in the proband carrying this gene defect. PMID:23595191

  16. Simulation of a Hydraulic Pump Control Valve

    Science.gov (United States)

    Molen, G. Vander; Akers, A.

    1987-01-01

    This paper describes the mode of operation of a control valve assembly that is used with a hydraulic pump. The operating system of the valve is modelled in a simplified form, and an analogy for hydraulic resonance of the pressure sensing system is presented. For the control valve investigated, air entrainment, length and diameter of the resonator neck, and valve mass produced the greatest shift in resonant frequency. Experimental work was conducted on the hydraulic system so that the resonance levels and frequencies could be measured and the accuracy of the theory verified. The results obtained make it possible to evaluate what changes to any of the variables considered would be most effective in driving the second harmonic frequency above the operating range.

  17. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  18. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cryogenic flow-control valve based on Venturi-Offset Technology (VOST) will be designed and modeled. VOST provides precise linear flow control within a...

  19. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A cylindrical, low-mass, high-efficiency, leak-proof cryogenic valve will be designed using composites and exotic metals. Based upon cryogenically-proven Venturi...

  20. VOST Flow-Control Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two cryogenic flow-control valves of diameters 1/2" and 2" will be built and tested. Based on cryogenically-proven Venturi Off-Set Technology (VOST) they have no...

  1. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  2. Contamination avoidance devices for poppettype shutoff valves

    Science.gov (United States)

    Endicott, D. L.

    1973-01-01

    The determination of the cycle life is reported of the scal closure of a typical poppet-type shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O3 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full-flow and cyclic-operating conditions, redesigned to improve the damage tolerance to contaminants, and then retested. The redesigned valve was found to have acceptable tolerance characteristics under all full-flow conditions and cyclic operation with small (25-75 microns) particulate contamination. The tolerance characteristics of the valve under cyclic conditions with large (75-250 microns) particulate contamination was improved but was not found to be completely satisfactory.

  3. Surgical Treatment of Congenital Mitral Valve Dysplasia.

    Science.gov (United States)

    Vida, Vladimiro L; Carrozzini, Massimiliano; Padalino, Massimo; Milanesi, Ornella; Stellin, Giovanni

    2016-05-01

    Congenital mitral valve (MV) dysplasia is a relatively rare and highly complex cardiac disease. We present our results and illustrate the techniques used to repair these valves. Between 1972 and 2014, 100 consecutive patients underwent surgical repair of congenital MV dysplasia at our institution. Predominant MV regurgitation was present in 53 patients (53%) whereas mitral stenosis was prevalent in 47 (47%). There were five early (5%) and eight late deaths (9%). Actuarial survival was 95%, 94%, and 93% at 5, 10, and 20 years, respectively. Sixteen patients (18%) required reintervention due to subsequent MV dysfunction. Actuarial freedom from reintervention for MV dysfunction was 95%, 92%, and 89% at 5, 10, and 20 years, respectively. The mechanism underlying the valve dysfunction in congenital mitral valve dysplasia is multifactorial and requires the application of a variety of surgical techniques for repair. doi: 10.1111/jocs.12743 (J Card Surg 2016;31:352-356). © 2016 Wiley Periodicals, Inc.

  4. Electrodynamic actuators for rocket engine valves

    Science.gov (United States)

    Fiet, O.; Doshi, D.

    1972-01-01

    Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.

  5. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  6. Percutaneous Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis

    Science.gov (United States)

    Malhotra, Rohit; Sharma, Anjali; Kakouros, Nikolaos

    2017-01-01

    Percutaneous transcatheter tricuspid balloon valvuloplasty (PTTBV) is an accepted treatment option for symptomatic severe native tricuspid valve stenosis, although surgical tricuspid valve replacement remains the treatment of choice. There have been few reports of successful PTTBV for bioprosthetic tricuspid valve stenosis. We present case reports of 3 patients from our hospital experience. Two of the 3 cases were successful, with lasting clinical improvement, whereas the 3rd patient failed to show a reduction in valve gradient. We describe the standard technique used for PTTBV. We present results from a literature review that identified 16 previously reported cases of PTTBV for bioprosthetic severe tricuspid stenosis, with overall favorable results. We conclude that PTTBV should perhaps be considered for a select patient population in which symptomatic improvement and hemodynamic stability are desired immediately, and particularly for patients who are inoperable or at high surgical risk.

  7. Minimally Invasive Transcatheter Aortic Valve Replacement (TAVR)

    Medline Plus

    Full Text Available Watch a Broward Health surgeon perform a minimally invasive Transcatheter Aortic Valve Replacement (TAVR) Click Here to view the BroadcastMed, Inc. Privacy Policy and Legal Notice © 2017 BroadcastMed, Inc. ...

  8. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness d

  9. Low-Mass VOST Valve Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Two low-mass, linear throttling, high-efficiency, leak-proof cryogenic valves of diameters 1/2" and 4" will be built and tested. Based upon cryogenically-proven...

  10. Transcatheter Aortic Valve Replacement in a Patient With a Previous Bioprosthetic Mitral Valve Replacement: Report of a Delayed Fatal Interaction.

    Science.gov (United States)

    Poulin, Frédéric; Lamarche, Yoan; Le, Van Hoai Viet; Doucet, Michel; Roméo, Philippe; Généreux, Philippe

    2016-02-01

    We report on a man with bioprosthetic mitral valve perforation who presented late after transcatheter aortic valve replacement with a balloon-expandable transcatheter heart valve (THV). The protrusion of the commissural strut of the bioprosthetic mitral valve coupled with the low implanted THV resulted in repetitive trauma leading to rupture of a mitral leaflet. Potential preventive strategies are discussed. This case illustrates the importance of preprocedural imaging screening and cautious THV deployment in patients with a bioprosthetic mitral valve.

  11. Tenecteplase in prosthetic mitral valve thrombosis

    OpenAIRE

    2010-01-01

    In the few reported cases of prosthetic mitral valve thrombosis, where surgical intervention was considered as high risk, fibrinolytic therapy had proved life saving. The authors present clinical, laboratory, and imaging data from such a patient, with prosthetic mitral valve thrombosis and its successful management with tenecteplase. The use of tenecteplase as a viable fibrinolytic agent for the first time was justified, due to the lack of immunogenicity concerns compared to streptokinase.

  12. Tenecteplase in prosthetic mitral valve thrombosis.

    Science.gov (United States)

    Ayyub Ghori, Masood; Bakir, Sherif; Ellahham, Samer; Al Nassir, Adnan; Al Zubaidi, Abdulmajeed; Augustin, Norbert; Abdelaziz, Moataz Ayman; Turrin, Nicolas Patrick; Al Mahmeed, Wael Abdulrahman

    2011-04-01

    In the few reported cases of prosthetic mitral valve thrombosis, where surgical intervention was considered as high risk, fibrinolytic therapy had proved life saving. The authors present clinical, laboratory, and imaging data from such a patient, with prosthetic mitral valve thrombosis and its successful management with tenecteplase. The use of tenecteplase as a viable fibrinolytic agent for the first time was justified, due to the lack of immunogenicity concerns compared to streptokinase.

  13. Symptomatic papillary tumour of the pulmonary valve

    OpenAIRE

    Cooper, Linda Carol

    1982-01-01

    Papillary ‘tumours’ are small pedunculated lesions of the valve cusps and result from wear-and-tear. They are therefore frequent post-mortem findings in older patients. The vast majority are clinically silent, though occasionally such lesions when on the aortic valve may produce symptoms of myocardial or cerebral ischaemia. None has been known to cause symptoms when in the right side of the heart.

  14. Reconstructive surgery of the aortic valve

    Directory of Open Access Journals (Sweden)

    Mendonça José Teles de

    2003-01-01

    Full Text Available OBJECTIVE: Lacking an ideal valve substitute and motivated by the good results of mitral valve repair since 1990, we faced with determination aortic valve reconstruction surgery. The objective of this paper is to show our experience with this procedure. METHOD: Between January of 1990 and December of 2001; 136 aortic valve repair surgeries were performed. Seventy-five (55.1% of the patients were female and the ages ranged from 4 to 70 years (mean 23.3 ± 1.2 years. Every patient had rheumatic valve disease and insufficiency was the most prevalent type (108 patients - 79.4%, followed by double aortic lesion in 16 (11.7% patients and stenosis in 12 (8.8%. The surgical techniques used were: subcommissural annuloplasty in 74 (54.4% patients, commissurotomy in 38 (27.9%, cusp extension with pericardium in 17 (12.5%, substitution of one cusp in 2 (1.4%, cusp suspension by annuloplasty in 37 (27.2% and Valsalva sinus remodeling in 27 (19.8%. The surgery exclusively involved the aortic valve in 57 (41.9% patients and was associated in 79 (mitral valve replacement in 12, mitral repair in 65, coronary artery bypass grafting in 1 and pulmonary commissurotomy in 1. RESULTS: Hospital mortality was 2.2% and 22 (16.2% patients underwent a new surgery during the follow-up period (57.7 ± 3.5 months. CONCLUSIONS: Aortic valve repair is a safe surgical procedure that can be used in an increasing number of patients with promising results.

  15. DIAGNOSTICS AND TREATMENT OF MITRAL VALVE PROLAPSE

    Directory of Open Access Journals (Sweden)

    D. A. Kuzhel

    2010-01-01

    Full Text Available The mitral valve prolapse (MVP is one of the most inconsistent diagnose. In the most cases patients with MVP have the good long-term prognosis, and therapy is aimed at reduction in psychovegetative dysfunction. Careful follow-up and timely cardiosurgical correction should be performed, if necessary, in patients with classical MPV. The choice method in these cases is the mitral valve plasty.

  16. Refuge alternatives relief valve testing and design.

    Science.gov (United States)

    Lutz, T J; Bissert, P T; Homce, G T; Yonkey, J A

    2016-10-01

    The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as specified by the manufacturer, above mine atmospheric pressure in the RA. To facilitate PRV testing, an instrumented benchtop test fixture was developed using an off-the-shelf centrifugal blower and ductwork. Relief pressures and flow characteristics were measured for three units: (1) a modified polyvinyl chloride check valve, (2) an off-the-shelf brass/cast-iron butterfly check valve and (3) a commercially available valve that was designed specifically for one manufacturer's steel prefabricated RAs and had been adapted for use in one mine operator's built-in-place RA. PRVs used in tent-style RAs were not investigated. The units were tested with different modifications and configurations in order to check compliance with Title 30 Code of Federal Regulations, or 30 CFR, regulations. The commercially available relief valve did not meet the 30 CFR relief pressure specification but may meet the manufacturer's specification. Alternative valve designs were modified to meet the 30 CFR relief pressure specification, but all valve designs will need further design research to examine survivability in the event of a 103 kPa (15.0 psi) impulse overpressure during a disaster.

  17. Fibrinolytic therapy for mechanical pulmonary valve thrombosis.

    Science.gov (United States)

    Khajali, Zahra; Mohammadzadeh, Shabnam; Maleki, Majid; Peighambari, Mohammad Mehdi; Sadeghpoor, Anita; Ghavidel, Alireza; Elahi, Behrad; Mirzaaghayan, Mohammadreza

    2015-01-01

    Treatment of prosthetic heart valve thrombosis using intravenous thrombolytics, although an acceptable alternative to surgery, is not complication free, and the literature has a dearth of data on the subject. This study analyzed the results of fibrinolytic treatment (FT) among a single-center group of patients with mechanical pulmonary valve thrombosis. Between 2000 and 2013, 23 consecutive patients with 25 episodes of pulmonary valve thrombosis received FT. The diagnosis of mechanical pulmonary valve thrombosis was established by fluoroscopy and echocardiography. Streptokinase (SK) was used in 24 cases and alteplase in 1 case. The FT was continued a second day for 14 patients (58.3%), a third day for 1 patient, and a fourth day for 1 patient. Echocardiography and fluoroscopy were performed every day until improvement of malfunction was achieved. Of the 23 patients, 19 had complete resolution of hemodynamic abnormalities after FT, 1 had partial resolution, and 2 showed no change. No patient had major complications. Five minor complications were detected, namely, fever, nausea, thrombophlebitis, epistaxi, and pain. Seven patients (30%) experienced recurrence of thrombosis, whereas four patients had surgery (biological pulmonary valve replacement) without re-thrombolytic therapy, one patient was treated with Alteplase, one patient received SK, and one patient received intense anticoagulation using heparin and warfarin. Overall, FT had a success rate of 84%. The results indicate that regardless of the time to pulmonary valve replacement and echocardiographic and fluoroscopic findings, FT was effective in most cases of mechanical pulmonary valve thrombosis. The efficacy increased with second-day thrombolytic therapy. Major complications were not common after lytic therapy for mechanical pulmonary valve thrombosis.

  18. Native valve Escherichia coli endocarditis following urosepsis.

    Science.gov (United States)

    Rangarajan, D; Ramakrishnan, S; Patro, K C; Devaraj, S; Krishnamurthy, V; Kothari, Y; Satyaki, N

    2013-05-01

    Gram-negative organisms are a rare cause of infective endocarditis. Escherichia coli, the most common cause of urinary tract infection and gram-negative septicemia involves endocardium rarely. In this case report, we describe infection of native mitral valve by E. coli following septicemia of urinary tract origin in a diabetic male; subsequently, he required prosthetic tissue valve replacement indicated by persistent sepsis and congestive cardiac failure.

  19. Europa Propulsion Valve Seat Material Testing

    Science.gov (United States)

    Addona, Brad M.

    2017-01-01

    The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

  20. 2D DIGITAL SIMPLIFIED FLOW VALVE

    Institute of Scientific and Technical Information of China (English)

    Ruan Jian; Li Sheng; Pei Xiang; Burton R; Ukrainetz P; Bitner D

    2004-01-01

    The 2D digital simplified flow valve is composed of a pilot-operated valve designed with both rotary and linear motions of a single spool,and a stepper motor under continual control.How the structural parameters affect the static and dynamic characteristics of the valve is first clarified and a criterion for stability is presented.Experiments are designed to test the performance of the valve.It is necessary to establish a balance between the static and dynamic characteristics in deciding the structural parameters.Nevertheless,it is possible to maintain the dynamic response at a fairly high level,while keeping the leakage of the pilot stage at an acceptable level.One of the features of the digital valve is stage control.In stage control the nonlinearities,such as electromagnetic saturation and hysteresis,are greatly reduced.To a large extent the dynamic response of the valve is decided by the executing cycle of the control algorithm.

  1. Pulmonary-Valve Replacement in Adults: Results With the Medtronic Freestyle Valve.

    Science.gov (United States)

    Ramanan, Sowmya; Doll, Nicolas; Boethig, Dietmar; Tafer, Nadir; Horke, Alexander; Roques, Xavier; Hemmer, Wolfgang Bruno; Roubertie, François

    2015-09-01

    We used the Medtronic Freestyle valve (Medtronic, Minneapolis, MN) as an orthotopic conduit in pulmonary valve replacement in repaired tetralogy of Fallot and as part of the Ross procedure. Midterm outcomes and hemodynamic status of this conduit were analyzed and performances in both subgroups were compared. From February 2002 to July 2012, 115 Freestyle valves were implanted in 52 patients with tetralogy of Fallot and 63 patients within the Ross procedure. Preoperative and perioperative data were reviewed retrospectively in this bicentric study. Mean age at valve surgery was 37 ± 13 years. Median implanted valve size was 27 mm (21 to 29). Early postoperative mortality was 3.48%. There was 100% follow-up for the survivors at a mean of 4.38 ± 2.52 years. There was 1 case of thromboembolism (0.89%), 6 endocarditis (5.4%), and 9 (7.8%) conduit re-interventions. Echocardiography at discharge and last follow-up showed average peak systolic transvalvular gradients of 12.4 ± 5.1 and 18.7 ± 8.8 mm Hg, respectively. Ten patients had significant proximal anastomotic gradients of greater than 50 mm Hg and 4 moderate conduit regurgitations. Survival was 96.52%. No valve degeneration was seen in 87.82% at 5 years. The only risk factor identified for valve re-intervention was conduit implantation without infundibular hood (p = 0.01 in multivariate analysis). Mid-term data show that Freestyle valves are well suited for pulmonary valve replacement in adults in both categories. The surgical technique used in valve implantation is important to ensure conduit durability. These results and accessibility to the Freestyle valve make this an acceptable alternative to homografts. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Electromechanically Actuated Valve for Controlling Flow Rate

    Science.gov (United States)

    Patterson, Paul

    2007-01-01

    A proposed valve for controlling the rate of flow of a fluid would include an electric-motor-driven ball-screw mechanism for adjusting the seating element of the valve to any position between fully closed and fully open. The motor would be of a type that can be electronically controlled to rotate to a specified angular position and to rotate at a specified rate, and the ball screw would enable accurate linear positioning of the seating element as a function of angular position of the motor. Hence, the proposed valve would enable fine electronic control of the rate of flow and the rate of change of flow. The uniqueness of this valve lies in a high degree of integration of the actuation mechanism with the flow-control components into a single, relatively compact unit. A notable feature of this integration is that in addition to being a major part of the actuation mechanism, the ball screw would also be a flow-control component: the ball screw would be hollow so as to contain part of the main flow passage, and one end of the ball screw would be the main seating valve element. The relationships among the components of the valve are best understood by reference to the figure, which presents meridional cross sections of the valve in the fully closed and fully open positions. The motor would be supported by a bracket bolted to the valve body. By means of gears or pulleys and a timing belt, motor drive would be transmitted to a sleeve that would rotate on bearings in the valve body. A ball nut inside the sleeve would be made to rotate with the sleeve by use of a key. The ball screw would pass through and engage the ball nut. A key would prevent rotation of the ball screw in the valve body while allowing the ball screw to translate axially when driven by the ball nut. The outer surface of the ball screw would be threaded only in a mid-length region: the end regions of the outer surface of the ball screw would be polished so that they could act as dynamic sealing surfaces

  3. Shape Memory Actuated Normally Open Permanent Isolation Valve

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Bacha, Caitlin E. (Inventor)

    2017-01-01

    A valve assembly for an in-space propulsion system includes an inlet tube, an outlet tube, a valve body coupling the inlet tube to the outlet tube and defining a propellant flow path, a valve stem assembly disposed within the valve body, an actuator body coupled to the valve body, the valve stem assembly extending from an interior of the valve body to an interior of the actuator body, and an actuator assembly disposed within the actuator body and coupled to the valve stem assembly, the actuator assembly including a shape memory actuator member that when heated to a transition temperature is configured to enable the valve stem assembly to engage the outlet tube and seal the propellant flow path.

  4. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  5. Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis

    DEFF Research Database (Denmark)

    Siontis, George C M; Praz, Fabien; Pilgrim, Thomas

    2016-01-01

    AIMS: In view of the currently available evidence from randomized trials, we aimed to compare the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the spectrum of risk and in important subgroups. METHODS AND RESULTS...

  6. Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung-Han; Lefèvre, Thierry; Ahn, Jung-Ming

    2016-01-01

    BACKGROUND: Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices. OBJECTIVE...

  7. 40 CFR 60.483-1 - Alternative standards for valves-allowable percentage of valves leaking.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Alternative standards for valves-allowable percentage of valves leaking. 60.483-1 Section 60.483-1 Protection of Environment ENVIRONMENTAL... Before November 7, 2006 § 60.483-1 Alternative standards for valves—allowable percentage of...

  8. Single-centre experience with mitral valve repair in asymptomatic patients with severe mitral valve regurgitation

    NARCIS (Netherlands)

    W.J. van Leeuwen (Wouter); S.J. Head (Stuart); L.E. de Groot-de Laat (Lotte); M.L. Geleijnse (Marcel); A.J.J.C. Bogers (Ad); L.A. van Herwerden (Lex); A.P. Kappetein (Arie Pieter)

    2013-01-01

    textabstractOBJECTIVES: Guidelines recommend surgical mitral valve repair in selected patients with asymptomatic severe mitral valve regurgitation (MR), but the role of repair remains a matter of debate. Survival analyses of operated asymptomatic patients have been reported, but long-term haemodynam

  9. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure

  10. Replacing the valve restoring the flow: Effects of transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Wiegerinck, E.M.A.

    2016-01-01

    When conventional surgery is not an option due to high surgical risk, transcatheter aortic valve implantation (TAVI) is a firmly established alternative and an effective and safe treatment option in this patient population. This thesis focuses on treatment of aortic valve stenosis by TAVI. The aim i

  11. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  12. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops

  13. Dynamic Heterogeneity of the Heart Valve Interstitial Cell Population in Mitral Valve Health and Disease

    Directory of Open Access Journals (Sweden)

    Tori E. Horne

    2015-08-01

    Full Text Available The heart valve interstitial cell (VIC population is dynamic and thought to mediate lay down and maintenance of the tri-laminar extracellular matrix (ECM structure within the developing and mature valve throughout life. Disturbances in the contribution and distribution of valve ECM components are detrimental to biomechanical function and associated with disease. This pathological process is associated with activation of resident VICs that in the absence of disease reside as quiescent cells. While these paradigms have been long standing, characterization of this abundant and ever-changing valve cell population is incomplete. Here we examine the expression pattern of Smooth muscle α-actin, Periostin, Twist1 and Vimentin in cultured VICs, heart valves from healthy embryonic, postnatal and adult mice, as well as mature valves from human patients and established mouse models of disease. We show that the VIC population is highly heterogeneous and phenotypes are dependent on age, species, location, and disease state. Furthermore, we identify phenotypic diversity across common models of mitral valve disease. These studies significantly contribute to characterizing the VIC population in health and disease and provide insights into the cellular dynamics that maintain valve structure in healthy adults and mediate pathologic remodeling in disease states.

  14. Advanced microbial check valve development

    Science.gov (United States)

    Colombo, G. V.; Greenley, D. R.

    1980-01-01

    A flight certified assembly identified as a Microbial Check Valve (MCV) was developed and tested. The MCV is a canister packed with an iodinated anionic exchange resin. The device is used to destroy organisms in a water stream as the water passes through the device. The device is equally effective for fluid flow in either direction and its primary method of organism removal is killing rather than filtering. The MCV was successfully developed for the space shuttle to: disinfect fuel cell water; and prevent back contamination of the stored potable water supply. One version of the device consists of a high residual iodinated resin bed that imparts approximately 2 ppm of iodine to the fuel cell water as it flows to the potable water tanks. A second version of the device consists of a low residual iodinated resin bed. One of these low residual beds is located at each use port in the potable water system for the dual purpose of removing some iodine from the potable water as it is dispensed and also to prevent back contamination of the potable supply.

  15. Exuberant accessory mitral valve tissue with possible true parachute mitral valve: a case report

    Directory of Open Access Journals (Sweden)

    Nikolic Aleksandra

    2012-09-01

    Full Text Available Abstract Introduction A parachute mitral valve is defined as a unifocal attachment of mitral valve chordae tendineae independent of the number of papillary muscles. Data from the literature suggests that the valve can be distinguished on the basis of morphological features as either a parachute-like asymmetrical mitral valve or a true parachute mitral valve. A parachute-like asymmetrical mitral valve has two papillary muscles; one is elongated and located higher in the left ventricle. A true parachute mitral valve has a single papillary muscle that receives all chordae, as was present in our patient. Patients with parachute mitral valves during childhood have multilevel left-side heart obstructions, with poor outcomes without operative treatment. The finding of a parachute mitral valve in an adult patient is extremely rare, especially as an isolated lesion. In adults, the unifocal attachment of the chordae results in a slightly restricted valve opening and, more frequently, valvular regurgitation. Case presentation A 40-year-old Caucasian female patient was admitted to a primary care physician due to her recent symptoms of heart palpitation and chest discomfort on effort. Transthoracic echocardiography showed chordae tendineae which were elongated and formed an unusual net shape penetrating into left ventricle cavity. The parasternal short axis view of her left ventricle showed a single papillary muscle positioned on one side in the posteromedial commissure receiving all chordae. Her mitral valve orifice was slightly eccentric and the chordae were converting into a single papillary muscle. Mitral regurgitation was present and it was graded as moderate to severe. Her left atrium was enlarged. There were no signs of mitral stenosis or a subvalvular ring. She did not have a bicuspid aortic valve or coarctation of the ascending aorta. The dimensions and systolic function of her left ventricle were normal. Our patient had a normal body habitus

  16. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  17. Recurrent stuck mitral valve: eosinophilia an unusual pathology.

    Science.gov (United States)

    Awasthy, Neeraj; Bhat, Yasser; Radhakrishnan, S; Sharma, Rajesh

    2015-03-01

    Eosinophilia is a very unusual and rare cause of thrombosis of prosthetic mitral valve. We report a 10-year-old male child of recurrent stuck prosthetic mitral valve. The child underwent mitral valve replacement for severe mitral regurgitation secondary to Rheumatic heart disease. He had recurrent prosthetic mitral valve thrombosis, despite desired INR levels. There was associated eosinophilia. The child was treated on the lines of tropical eosinophilia with oral prednisolone and diethylcarbamazine, the eosinophil count dropped significantly with no subsequent episode of stuck mitral valve. We discuss the management of recurrent stuck mitral valve and also eosinophilia as a causative factor for the same.

  18. Fluid dynamic characterization of a polymeric heart valve prototype (Poli-Valve) tested under continuous and pulsatile flow conditions.

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D; Costantino, Maria Laura

    2015-11-01

    Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.

  19. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  20. Management of moderate functional tricuspid valve regurgitation at the time of pulmonary valve replacement: is concomitant tricuspid valve repair necessary?

    Science.gov (United States)

    Kogon, Brian; Patel, Manisha; Leong, Traci; McConnell, Michael; Book, Wendy

    2010-08-01

    Congenital heart defects with a component of pulmonary stenosis are often palliated in childhood by disrupting the pulmonary valve. Patients often undergo subsequent pulmonary valve replacement (PVR) to protect the heart from the consequences of pulmonary regurgitation. In the presence of associated moderate functional tricuspid valve (TV) regurgitation, it is unclear what factors contribute to persistent TV regurgitation following PVR. In particular, it is unknown whether PVR alone will reduce the right ventricular (RV) size and restore TV function or whether concomitant TV annuloplasty is required as well. Thirty-five patients were analyzed. Each patient underwent initial palliation of congenital pulmonary stenosis or tetralogy of Fallot, underwent subsequent PVR between 2002 and 2008, and had at least moderate TV regurgitation at the time of valve replacement. Serial echocardiograms were analyzed. Pulmonary and TV regurgitation, along with RV dilation and dysfunction, were scored (0, none; 1, mild; 2, moderate; 3, severe). RV volume and area were also calculated. Potential risk factors for persistent postoperative TV regurgitation were evaluated. One month following PVR, there was a significant reduction in pulmonary valve regurgitation (mean, 3 vs. 0.39; P regurgitation (mean, 2.33 vs. 1.3; P regurgitation postoperatively between those patients who underwent PVR alone and those who underwent concomitant tricuspid annuloplasty (mean, 1.29 vs. 1.31; P = 0.81). We conclude that following PVR, improvement in TV regurgitation and RV size occurs primarily in the first postoperative month. TV function improved to a similar degree with or without annuloplasty.

  1. Loss of Axin2 results in impaired heart valve maturation and subsequent myxomatous valve disease.

    Science.gov (United States)

    Hulin, Alexia; Moore, Vicky; James, Jeanne M; Yutzey, Katherine E

    2017-01-01

    Myxomatous valve disease (MVD) is the most common aetiology of primary mitral regurgitation. Recent studies suggest that defects in heart valve development can lead to heart valve disease in adults. Wnt/β-catenin signalling is active during heart valve development and has been reported in human MVD. The consequences of increased Wnt/β-catenin signalling due to Axin2 deficiency in postnatal valve remodelling and pathogenesis of MVD were determined. To investigate the role of Wnt/β-catenin signalling, we analysed heart valves from mice deficient in Axin2 (KO), a negative regulator of Wnt/β-catenin signalling. Axin2 KO mice display enlarged mitral and aortic valves (AoV) after birth with increased Wnt/β-catenin signalling and cell proliferation, whereas Sox9 expression and collagen deposition are decreased. At 2 months in Axin2 KO mice, the valve extracellular matrix (ECM) is stratified but distal AoV leaflets remain thickened and develop aortic insufficiency. Progressive myxomatous degeneration is apparent at 4 months with extensive ECM remodelling and focal aggrecan-rich areas, along with increased BMP signalling. Infiltration of inflammatory cells is also observed in Axin2 KO AoV prior to ECM remodelling. Overall, these features are consistent with the progression of human MVD. Finally, Axin2 expression is decreased and Wnt/β-catenin signalling is increased in myxomatous mitral valves in a murine model of Marfan syndrome, supporting the importance of Wnt/β-catenin signalling in the development of MVD. Altogether, these data indicate that Axin2 limits Wnt/β-catenin signalling after birth and allows proper heart valve maturation. Moreover, dysregulation of Wnt/β-catenin signalling resulting from loss of Axin2 leads to progressive MVD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  2. Presentation of the development of the SRV valve (safety relief valve); Presentation du developpement de la vanne SRV (Safety Relief Valve)

    Energy Technology Data Exchange (ETDEWEB)

    Manguette, P. [Adareg, 59 - Haubourdin (France)

    1998-09-01

    Adareg has 30 years experience in Hydrane and control valves. Its know-how moves towards extreme technologies: control of all types of fluids (hot, cold, aggressive ones, clean ones etc... ). A perfect control is essential for very low temperatures (nuclear submarines, Ariane). Adareg Research and Development activities, certified ISO 9001, have developed valves accepting temperatures reaching 2 degrees above the absolute 0. Increasing requirements concerning low temperatures have encouraged Adareg to develop a research programme in partnership with CEA - French Atomic Energy Commission - for valves type 'SRV' (Safety Relief Valves). This type of valve is designed for a new accelerator of particles, the LHC, at CERN, in Geneva. (author)

  3. Cardiac crossroads: deciding between mechanical or bioprosthetic heart valve replacement

    Directory of Open Access Journals (Sweden)

    Maggie N Tillquist

    2011-02-01

    Full Text Available Maggie N Tillquist1, Thomas M Maddox21School of Medicine, University of Colorado Denver, Denver, CO, USA; 2VA Eastern Colorado Health Care System, and Department of Medicine (Cardiology, University of Colorado Denver, Denver, CO, USAAbstract: Nearly 15 million people in the United States suffer from either aortic or mitral valvular disease. For patients with severe and symptomatic valvular heart disease, valve replacement surgery improves morbidity and mortality outcomes. In 2009, 90,000 valve replacement surgeries were performed in the United States. This review evaluates the advantages and disadvantages of mechanical and bioprosthetic prosthetic heart valves as well as the factors for consideration in deciding the appropriate valve type for an individual patient. Although many caveats exist, the general recommendation is for patients younger than 60 to 65 years to receive mechanical valves due to the valve's longer durability and for patients older than 60 to 65 years to receive a bioprosthetic valve to avoid complications with anticoagulants. Situations that warrant special consideration include patient co-morbidities, the need for anticoagulation, and the potential for pregnancy. Once these characteristics have been considered, patients' values, anxieties, and expectations for their lifestyle and quality of life should be incorporated into final valve selection. Decision aids can be useful in integrating preferences in the valve decision. Finally, future directions in valve technology, anticoagulation, and medical decision-making are discussed.Keywords: prosthetic heart valves, patient preference, valve type, anticoagulant, structural valve deterioration 

  4. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  5. A capillary valve for microfluidic systems.

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, Eric B.; Kanouff, Michael P.; Rush, Brian M.

    2004-10-01

    Microfluidic systems are becoming increasingly complicated as the number of applications grows. The use of microfluidic systems for chemical and biological agent detection, for example, requires that a given sample be subjected to many process steps, which requires microvalves to control the position and transport of the sample. Each microfluidic application has its own specific valve requirements and this has precipitated the wide variety of valve designs reported in the literature. Each of these valve designs has its strengths and weaknesses. The strength of the valve design proposed here is its simplicity, which makes it easy to fabricate, easy to actuate, and easy to integrate with a microfluidic system. It can be applied to either gas phase or liquid phase systems. This novel design uses a secondary fluid to stop the flow of the primary fluid in the system. The secondary fluid must be chosen based on the type of flow that it must stop. A dielectric fluid must be used for a liquid phase flow driven by electroosmosis, and a liquid with a large surface tension should be used to stop a gas phase flow driven by a weak pressure differential. Experiments were carried out investigating certain critical functions of the design. These experiments verified that the secondary fluid can be reversibly moved between its 'valve opened' and 'valve closed' positions, where the secondary fluid remained as one contiguous piece during this transport process. The experiments also verified that when Fluorinert is used as the secondary fluid, the valve can break an electric circuit. It was found necessary to apply a hydrophobic coating to the microchannels to stop the primary fluid, an aqueous electrolyte, from wicking past the Fluorinert and short-circuiting the valve. A simple model was used to develop valve designs that could be closed using an electrokinetic pump, and re-opened by simply turning the pump off and allowing capillary forces to push the secondary

  6. Fabrication of micro metallic valve and pump

    Science.gov (United States)

    Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi

    2010-03-01

    Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.

  7. Prosthetic Valve Thrombosis: Diagnosis and Management.

    Science.gov (United States)

    Garg, Jalaj; Palaniswamy, Chandrasekar; Pinnamaneni, Sowmya; Sarungbam, Judy; Jain, Diwakar

    2016-01-01

    St. Jude mechanical prosthesis is the most commonly used prosthetic device with least valvular complications with excellent hemodynamics. However, prosthetic valve thrombosis is one of the serious complications, with rates between 0.03% and 0.13% per patient-year depending on the type of anticoagulation used and compliance to the therapy. Transthoracic echocardiography (TTE) is the initial screening tool (class I) that would provide clues for the assessment of valvular hemodynamics. Fluoroscopy is an alternate imaging modality for the assessment of mechanical leaflet motion, especially in patients when prosthetic valves are difficult to image on TTE or transesophageal echocardiography. A complete fluoroscopic evaluation of a prosthetic valve includes assessment of valvular motion and structural integrity. Opening and closing angles can be measured fluoroscopically to determine whether a specific valve is functioning properly. We discuss a case of a 91-year-old man with thrombosis of bileaflet mechanical mitral prosthesis that was demonstrated on real-time fluoroscopy (not evident on TTE). An algorithmic approach to diagnosis and management of prosthetic heart valve thrombosis is outlined.

  8. Lymphangiogenesis is increased in heart valve endocarditis.

    Science.gov (United States)

    Niinimäki, Eetu; Mennander, Ari A; Paavonen, Timo; Kholová, Ivana

    2016-09-15

    Inflammation-associated lymphangiogenesis (IAL) has been identified as part of several acute and chronic inflammation. Sparse data exist on lymphatics during endocarditis. Fifty-two patients with surgically resected valves were included. Endocarditis was present in 18 aortic and 10 mitral valves. Controls consisted of 15 degenerative aortic and 9 degenerative mitral valves. There were 22 males with endocarditis and 17 males in controls. The mean age was 58 (SD 15) years with endocarditis vs. 62 (SD 13) years for controls. Lymphatics were detected by podoplanin antibody immunohistochemistry and morphometrical analysis was performed. The lymphatic density in endocarditis was 833 (SD 529) vessels/mm(2) (range 0-1707) as compared with 39 (SD 60) vessels/mm(2) (range 0-250) in controls (p=0.000). In endocarditis, the mean lymphatic size was 153 (SD 372) μm(2) ranging from 1 to 2034μm(2), whereas it was 30 (SD 29) μm(2), with maximum 90μm(2) and minimum 2μm(2) in controls (p=0.000). IAL is increased in valves with endocarditis as compared with controls. Lymphatics in heart valves may provide a novel means for treatment strategies against endocarditis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Living artificial heart valve alternatives: a review

    Directory of Open Access Journals (Sweden)

    Flanagan T. C.

    2003-11-01

    Full Text Available Conventional replacement therapies for heart valve disease are associated with significant drawbacks. The field of tissue engineering has emerged as an exciting alternative in the search for improved heart valve replacement structures. One of the principles behind this concept is the transplantation of living elements, embedded in a suitable scaffold material, to the diseased site where the structure becomes integrated with patients' tissue to restore natural function. Significant progress has been made in the last ten years in the development of a living artificial heart valve alternative (LAHVA, with the identification of potential replacement sources for valve cells, scaffolds to maintain the cells in a three-dimensional environment, and signals to promote tissue development. This review addresses the need for a tissue-engineered alternative to current prostheses and provides a detailed account of normal heart valve structure - the blueprint for LAHVA fabrication. The research efforts to create a viable LAHVA, including recent developments, are discussed. Particular attention is focused on the choice of cell source for LAHVA construction, the use of biodegradable natural and synthetic polymeric scaffolds as extracellular matrix derivatives, and exogenous stimulation of tissue growth. The critical challenges involved in LAHVA development and possible future areas of investigation are also discussed.

  10. DONOR HEART VALVES RECONSTRUCTION BEFORE TRANSPLANTATION

    Directory of Open Access Journals (Sweden)

    S. V. Gautier

    2013-01-01

    Full Text Available Aim of study. The demonstration of our own experience in heart transplantation after valve reconstruction. Methods and results. From May 2012 to March 2013 3 mitral valve annuloplasties were performed to recipi- ents, requiring urgent HT and having extremely unfavorable prognosis of survival without HT. The recipients were classified as United Network for Organ Sharing (UNOS IB, and all of them were on inotropic support. In one case, HT was performed after reconstruction of rheumatic mitral stenosis, in two other cases – after dege- nerative mitral regurgitation. The technical aspects are reviewed of ex-vivo mitral and tricuspid valves repair with concomitant heart transplantation. All patients were discharged from the hospital having excellent postope- rative recovery. Conclusion. Taking into consideration the demonstrated satisfactory result of surveillance and presence of significant experience in performing of reconstructive valve surgery among no-HT cardiosurgical patients, an increase in the pool of suitable donor organs is expected due to the liberalization of the selection criteria and the possibility of the innovative valve reconstruction procedures ex vivo. 

  11. Aortic valve replacement in octogenarians

    Directory of Open Access Journals (Sweden)

    Dark John H

    2007-07-01

    Full Text Available Abstract Background and Aims As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR in octogenarians. Methods 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37 underwent isolated AVR whilst 46% (31 underwent combined AVR and CABG. Results Follow up was 100% complete. The mean age was 83.1 ± s.d. 2.9 years, a mean gradient of 83 ± s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 ± s.d. 1.2, the logistic EuroSCORE mean 12.0 ± s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p Conclusion Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.

  12. Determination of flow-rate characteristics and parameters of piezo pilot valves

    Directory of Open Access Journals (Sweden)

    Takosoglu Jakub

    2017-01-01

    Full Text Available Pneumatic directional valves are used in most industrial pneumatic systems. Most of them are two-stage valves controlled by a pilot valve. Pilot valves are often chosen randomly. Experimental studies in order to determine the flow-rate characteristics and parameters of pilot valves were not conducted. The paper presents experimental research of two piezo pilot valves.

  13. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  14. Dynamic characterization of a new accelerated heart valve tester.

    Science.gov (United States)

    Menzler, F; Haubold, A D; Hwang, N H

    1997-01-01

    This paper presents a new accelerated prosthetic heart valve tester prototype that incorporates a camshaft and poppet valves. A three element Windkessel system is used to mimic the afterload of the human systemic circulation. The device is capable of testing eight valves simultaneously at a rate up to 1,250 cycles/min, while the flow rate, the pressure, and the valve loading can be monitored and adjusted individually. The tester was characterized and calibrated using a set of eight Carpentier-Edwards bioprostheses at a flow rate varying between 3 and 5 L/min. The experiment was carried out with the pressure difference across the closed heart valve maintained between 140 and 190 mmHg. Smooth and complete opening and closing of the valve leaflets was achieved at all cycling rates. This confirms that the velocity profiles approaching the test valves were uniform, an important factor that allows the test valves to open and close synchronously each time.

  15. What Are the Signs and Symptoms of Heart Valve Disease?

    Science.gov (United States)

    ... notice a fluttering, racing, or irregular heartbeat. Some types of heart valve disease, such as aortic or mitral valve stenosis, can cause dizziness or fainting. ... FEAR ACT OIG CONTACT US National Institutes of Health ...

  16. Valve timing: its effect on emissions and fuel economy

    Energy Technology Data Exchange (ETDEWEB)

    Bechtold, R.L.; Marshall, W.F.

    1977-08-01

    The effects of valve timing on exhaust emissions and fuel consumption were investigated experimentally. Emission control through the use of varied valve timing compared to conventional emissions control hardware was documented along with the effects of valve timing on emissions. Fuel consumption trends with changed valve timing were determined. The engine design of the test vehicle allowed independent adjustment of intake and exhaust valve timing. Emissions and fuel consumption were determined for steady-state speeds of 20 through 60 mph in 10 mph increments. A wide variety of intake and exhaust valve timing combinations were tested and the results compared to those of the production vehicle before modification. These results showed that valve timing has a significant effect on oxides of nitrogen emissions, but additional emissions control hardware is necessary to meet current and proposed emission regulations. Compared to emission control, varied valve timing holds more promise for reduced fuel consumption through a gain in cycle efficiency at various speeds.

  17. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  18. Mechanical Designs for Relief Valves for Cryogenic Apparatuses and Installations

    CERN Document Server

    CERN. Geneva

    2016-01-01

    There are also pressure relief valves with warm seat available on which the set pressure is based on an adjustment of forces by permanent magnets. Pressure vessel rules allows also the choice for an active triggered pressure relief valve (Cont...

  19. JetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement.

    Science.gov (United States)

    Capulli, Andrew K; Emmert, Maximillian Y; Pasqualini, Francesco S; Kehl, Debora; Caliskan, Etem; Lind, Johan U; Sheehy, Sean P; Park, Sung Jin; Ahn, Seungkuk; Weber, Benedikt; Goss, Josue A; Hoerstrup, Simon P; Parker, Kevin Kit

    2017-07-01

    Tissue engineered scaffolds have emerged as a promising solution for heart valve replacement because of their potential for regeneration. However, traditional heart valve tissue engineering has relied on resource-intensive, cell-based manufacturing, which increases cost and hinders clinical translation. To overcome these limitations, in situ tissue engineering approaches aim to develop scaffold materials and manufacturing processes that elicit endogenous tissue remodeling and repair. Yet despite recent advances in synthetic materials manufacturing, there remains a lack of cell-free, automated approaches for rapidly producing biomimetic heart valve scaffolds. Here, we designed a jet spinning process for the rapid and automated fabrication of fibrous heart valve scaffolds. The composition, multiscale architecture, and mechanical properties of the scaffolds were tailored to mimic that of the native leaflet fibrosa and assembled into three dimensional, semilunar valve structures. We demonstrated controlled modulation of these scaffold parameters and show initial biocompatibility and functionality in vitro. Valves were minimally-invasively deployed via transapical access to the pulmonary valve position in an ovine model and shown to be functional for 15 h. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Doppler echocardiography in normal functioning valve prostheses.

    Science.gov (United States)

    Cha, R; Yang, S S; Salvucci, T; DiBlasi, S

    1994-09-01

    Even though there has been some criticism regarding the Doppler evaluation in prosthetic valves because of inter-observer and intra-observer variability, among other factors, and Doppler study has a tendency to have falsely high gradients compared to invasive studies, especially mechanical aortic prostheses, Doppler evaluation can provide reliable hemodynamic information about valve function. This test may be particularly useful if used serially, when baseline values are known. Doppler measurement of gradient and valve area has an expected normal range that is specific for the prosthetic type, size, anatomical position, and chronological age. Clearly, a database involving these aspects is needed to provide a more accurate normal range. This study is intended to provide guidance for echocardiographers.

  1. Double Valve Replacement for Lupus Valvulitis

    Science.gov (United States)

    Ferraris, Victor A.; Hawksley, Vaughn C.; Rabinowitz, Max; Coyne, Carolyn M.; Sullivan, Thomas J.; Sprague, Merle S.

    1990-01-01

    Hemodynamically significant lupus valvulitis, requiring valve replacement, is rare: 21 cases have been reported so far in the literature, and only 2 of these have involved double valve replacement. We describe an additional case of double valve replacement in a patient with systemic lupus erythematosus. The histopathologic and clinical features of this case suggest that valvular involvement resulted from both acute and chronic disease processes. Medical success in the treatment of systemic lupus erythematosus, especially that achieved through prolonged or high-dose steroid therapy, may cause chronic valvular disease to become a more common surgical problem. A review of the literature supports this contention. (Texas Heart Institute Journal 1990;17:56-60) Images PMID:15227191

  2. A cryogenic valve for spacecraft applications

    Science.gov (United States)

    Salerno, L. J.; Spivak, A. L.

    1982-01-01

    Space-compatible cryogenic valves are now required to operate between room and liquid helium temperatures. A remotely controllable cryogenic valve is described, which is made of bellows-type stainless steel and is operated by a miniature dc motor with integral gearset (485:1) at a nominal voltage of 28 Vdc. The power transmission provides a further reduction of 7.2:1 to give an overall gear ratio of nearly 3500:1, assuring reliability of operation at low temperatures. Valve performance (leak rate) data are presented at LN2, LHe, and SfHe temperatures at delivered torques of 18, 27, 31, and 35 N-m. At a closing torque of 31 N-m, a leak rate of 0.028 scc/sec was achieved at 2 K, while at a torque of 18 N-m the leak rate at 300 K was less than 3 x 10 to the -9th scc/sec.

  3. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.

  4. Fluid damping clearance in a control valve of injector

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jianming; ZHANG Weigang; YANG Bing; WANG Yawei

    2007-01-01

    A force model of a control valve of injector is set up, and the changes of the fluid damping clearance are investigated on the basis of the results of the computational fluid dynamics (CFD) and the experiments of control valve of injector. Results indicate that a damping clearance of 0.02-0.03 mm between the poppet and the valve guide is the most sufficient to dampen any excessive control valve poppet bouncing.

  5. Unusual redo mitral valve replacement for bleeding in Glanzmann thrombasthenia.

    Science.gov (United States)

    Garcia-Villarreal, Ovidio A; Fernández-Ceseña, Ernesto; Solano-Ricardi, Mercedes; Aguilar-García, Alma L; Vega-Hernández, Raquel; Del Angel-Soto, Gustavo

    2016-01-01

    We report the case of 23-year-old man with mitral valve regurgitation and Glanzmann thrombasthenia, who underwent mechanical mitral valve replacement. Warfarin therapy was devastating, causing bilateral hemothorax, pericardial effusion, gastrointestinal bleeding, and hematuria. Redo mitral valve replacement with a biological prosthesis was required to resolve this critical situation. To our knowledge, this is the first report of mitral valve replacement in Glanzmann thrombasthenia, highlighting the danger of oral anticoagulation in this pathology.

  6. Transient Effects on Dynamic Torque for Butterfly Valves

    OpenAIRE

    Price, Trevor N.

    2013-01-01

    Butterfly valves are versatile components widely used in hydraulic systems as shutoff and throttling valves. Butterfly valve components must be able to withstand the forces and torques that are generated with use. Dynamic torque data are usually obtained in a test lab for a variety of steady state flow conditions; however the dynamic torque under transient (unsteady flow) conditions may be significantly different than that found in the laboratory. If a valve is closed too fast, especially in ...

  7. AeroValve Experimental Test Data Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, Mark W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-09-01

    This report documents the collection of experimental test data and presents performance characteristics for the AeroValve brand prototype pneumatic bidirectional solenoid valves tested at the Oak Ridge National Laboratory (ORNL) in July/August 2014 as part of a validation of AeroValve energy efficiency claims. The test stand and control programs were provided by AeroValve. All raw data and processing are included in the report attachments.

  8. Apicoaortic conduit for severe hemolytic anemia after aortic valve replacement.

    Science.gov (United States)

    Hatori, Kyohei; Ohki, Satoshi; Obayashi, Tamiyuki; Koyano, Tetsuya; Yasuhara, Kiyomitsu; Hirai, Hanako

    2015-06-01

    We describe the case of an 82-year-old woman who had undergone aortic mechanical valve replacement for aortic stenosis with a small annulus, and coronary artery bypass grafting. Four years after the operation, she began to experience hemolysis. Prosthetic valve obstruction was observed but there was no paravalvular leakage or aortic regurgitation through the mechanical valve. We elected to perform apicoaortic bypass in this patient with severe hemolytic anemia secondary to a mechanical valve malfunction.

  9. Exhaust gas bypass valve control for thermoelectric generator

    Science.gov (United States)

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  10. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  11. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  12. Direct aortic transcatheter valve implantation via mini-thoracotomy using the Medtronic CoreValve.

    Science.gov (United States)

    Bruschi, Giuseppe; Botta, Luca; De Marco, Federico; Colombo, Paola; Nonini, Sandra; Klugmann, Silvio; Martinelli, Luigi

    2013-01-01

    Transcatheter aortic valve implantation using the Medtronic CoreValve is a well-established procedure. Although previously carried out only through the common femoral artery, today it is possible to perform the procedure through different arterial alternative access sites. A direct aortic approach through the ascending aorta could be carried out via a right anterior mini-thoracotomy in the second intercostal space. The pericardium is opened to expose the aorta. Two purse-string sutures are then placed on the ascending aorta and a standard retrograde CoreValve implantation is performed with the standard delivery system. Advantages, contraindications, surgical technique and results are discussed.

  13. Autonomous valve for detection of biopolymer degradation

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Noeth, Nadine-Nicole; Fetz, Stefanie

    2009-01-01

    We present a polymer microvalve that allows the detection of biopolymer degradation without the need of external energy. The valve is based on a polymer container filled with a colored marker solution and closed by a thin lid. This structure is covered by a film of poly(L-lactide) and degradation...... of the biopolymer triggers the release of the color which is detected visually. The autonomous valve has potential for the fast testing of biopolymer degradation under various environmental conditions or by specific enzymes....

  14. The serpentine mitral valve and cerebral embolism

    Directory of Open Access Journals (Sweden)

    Ker James

    2011-02-01

    Full Text Available Abstract Valvular strands, well-delineated filiform masses, attached to cardiac valve edges are associated with cerebral embolism and stroke. Strokes, caused by emboli from valvular strands, tend to occur among younger persons. In this case report a valvular strand, giving a peculiar serpentine appearance to the mitral valve is described. This mitral valvular strand was the only explanation for an episode of cerebral embolism, presenting with a transient right sided hemiparesis. It is proposed that a randomized study involving combined treatment with aspirin and clopidogrel is warranted in young patients with valvular strands, presenting with a first episode of cerebral embolism.

  15. Multimodality Imaging of Heart Valve Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, Ronak, E-mail: Dr.R.Rajani@gmail.com [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom); Khattar, Rajdeep [Department of Cardiology, Royal Brompton Hospital, London (United Kingdom); Chiribiri, Amedeo [Divisions of Imaging Sciences, The Rayne Institute, St. Thomas' Hospital, London (United Kingdom); Victor, Kelly; Chambers, John [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom)

    2014-09-15

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

  16. Multimodality Imaging of Heart Valve Disease

    Directory of Open Access Journals (Sweden)

    Ronak Rajani

    2014-09-01

    Full Text Available Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance and discusses their relative strengths and weaknesses.

  17. Cooper pairs spintronics in triplet spin valves.

    Science.gov (United States)

    Romeo, F; Citro, R

    2013-11-27

    We study a spin valve with a triplet superconductor spacer intercalated between two ferromagnets with noncollinear magnetizations. We show that the magnetoresistance of the triplet spin valve depends on the relative orientations of the d vector, characterizing the superconducting order parameter, and the magnetization directions of the ferromagnetic layers. For devices characterized by a long superconductor, the effects of a polarized current sustained by Cooper pairs only are observed. In this regime, a supermagnetoresistance effect emerges, and the chiral symmetry of the order parameter of the superconducting spacer is easily recognized. Our findings open new perspectives in designing spintronics devices based on the cooperation of ferromagnetic and triplet correlations.

  18. Remote operated valves - the Bolivian approach

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar, O.; Arce, G.; Blanco, E.; Collazos, A.; Chavarria, E. [Transredes S.A., Transporte de Hidrocarburos, La Paz (Bolivia)

    2005-07-01

    For pipeline operators, the Remote Operated Valves (ROV) are tools to isolate pipe segments and contain any potential spill and they are also useful tools to provide data on operating conditions. Projects and articles about the locations and site layouts were developed to install Remote Operated Valves and the criteria for their use; each location has its own environmental, social and logistical particulars. This article describes the approach used to install ROV in Bolivia and the final design installed discussions and lessons learned about the: criteria to define the location, layout equipment installed and shelter and particulars of the location. (author)

  19. 46 CFR 154.519 - Piping relief valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Piping relief valves. 154.519 Section 154.519 Shipping... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo...

  20. 46 CFR 45.155 - Inlets and discharge piping: Valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Inlets and discharge piping: Valves. 45.155 Section 45... LINES Conditions of Assignment § 45.155 Inlets and discharge piping: Valves. (a) Except as provided in... visited by the crew. (e) Through-hull piping systems in machinery spaces may have valves with...

  1. 46 CFR 61.05-20 - Boiler safety valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler safety valves. 61.05-20 Section 61.05-20 Shipping... INSPECTIONS Tests and Inspections of Boilers § 61.05-20 Boiler safety valves. Each safety valve for a drum, superheater, or reheater of a boiler shall be tested at the interval specified by table 61.05-10....

  2. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance: Transmission lines. 192.745... TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.745 Valve maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  3. Prosthetic valve endocarditis caused by Acinetobacter calcoaceticus subsp. lwoffi.

    OpenAIRE

    Weinberger, I. (Ingeburg); Davidson, E.; Rotenberg, Z; Fuchs, J; Agmon, J

    1987-01-01

    Acinetobacter spp. are uncommon etiologic agents of prosthetic valve endocarditis. Two patients with Acinetobacter calcoaceticus subsp. lwoffi prosthetic valve endocarditis are described. The patients were successfully treated with antibiotics (cefotaxime sodium and gentamicin sulfate); thus, we suggest medical treatment rather than early valve replacement in this particular type of infection.

  4. Low-power piezoelectric micro-machined valve

    Science.gov (United States)

    Gianchandani, Yogesh B. (Inventor); Nellis, Gregory Francis (Inventor); Klein, Sanford A. (Inventor); Park, John Moon (Inventor); Evans, Allan Thomas (Inventor); Taylor, Ryan (Inventor); Brosten, Tyler R. (Inventor)

    2010-01-01

    A piezoelectric microvalve employs a valve element formed of hermetically sealed and opposed plates flexed together by a cross axis piezoelectric element. Large flow modulation with small piezoelectric actuator displacement is obtained by perimeter augmentation of the valve seat which dramatically increases the change in valve flow area for small deflections.

  5. 49 CFR 230.52 - Water glass valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Water glass valves. 230.52 Section 230.52... Water Glasses and Gauge Cocks § 230.52 Water glass valves. All water glasses shall be equipped with no more than two valves capable of isolating the water glass from the boiler. They shall also be equipped...

  6. 49 CFR 192.193 - Valve installation in plastic pipe.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve installation in plastic pipe. 192.193... Components § 192.193 Valve installation in plastic pipe. Each valve installed in plastic pipe must be designed so as to protect the plastic material against excessive torsional or shearing loads when the...

  7. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment...

  8. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if there...

  9. 49 CFR 236.837 - Valve, electro-pneumatic.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or prevent...

  10. Development of a stainless steel check valve for cryogenic applications

    NARCIS (Netherlands)

    Veenstra, T.T.; Venhorst, G.C.F.; Burger, J.F.; Holland, H.J.; Brake, ter H.J.M.; Sirbi, A.; Rogalla, H.

    2007-01-01

    This paper describes the development of a check valve for use in a sorption compressor that will drive a 10 mW 4.5 K Joule–Thomson cryocooler. For the check valve extremely low backflow rates are tolerable at an operating temperature of the valve of 50 K. To fulfill these requirements, the sealing m

  11. The Warm, Rich Sound of Valve Guitar Amplifiers

    Science.gov (United States)

    Keeports, David

    2017-01-01

    Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier…

  12. 30 CFR 57.4603 - Closure of valves.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Closure of valves. 57.4603 Section 57.4603... Control Welding/cutting/compressed Gases § 57.4603 Closure of valves. To prevent accidental release of... or manifold system valves shall be closed when— (a) The cylinders are moved; (b) The torch and...

  13. 46 CFR 122.608 - Fuel shutoff valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fuel shutoff valves. 122.608 Section 122.608 Shipping....608 Fuel shutoff valves. Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operations....

  14. 14 CFR 23.995 - Fuel valves and controls.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel valves and controls. 23.995 Section 23... Components § 23.995 Fuel valves and controls. (a) There must be a means to allow appropriate flight crew members to rapidly shut off, in flight, the fuel to each engine individually. (b) No shutoff valve may...

  15. 30 CFR 56.4603 - Closure of valves.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Closure of valves. 56.4603 Section 56.4603... Control Welding/cutting/compressed Gases § 56.4603 Closure of valves. To prevent accidental release of... or manifold system valves shall be closed when— (a) The cylinders are moved; (b) The torch and...

  16. 46 CFR 169.746 - Fuel shutoff valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fuel shutoff valves. 169.746 Section 169.746 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.746 Fuel shutoff valves. Each remote fuel shutoff station must be marked in at least 1-inch letters indicating purpose of the valves and...

  17. 46 CFR 98.25-60 - Safety relief valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Safety relief valves. 98.25-60 Section 98.25-60 Shipping... § 98.25-60 Safety relief valves. (a) Each tank shall be fitted with two or more approved safety relief valves, designed, constructed, and flow-tested for capacity in conformance with subpart 162.018...

  18. 46 CFR 153.980 - Isolation of automatic closing valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Isolation of automatic closing valves. 153.980 Section... Transfer Procedures § 153.980 Isolation of automatic closing valves. The person in charge of cargo transfer may isolate automatic closing valves described in § 153.408(b) from a cargo containment system if...

  19. Make Your Own Working Models of Heart Valves!

    Science.gov (United States)

    Hudson, Margaret L.

    2014-01-01

    Heart valves play a vital role in efficient circulation of the blood, and the details of their physical structure are related crucially to their function. However, it can be challenging for the learner to make the mental connection between anatomical structures of valves and the changing pressure gradients that the valves experience and come to an…

  20. 46 CFR 78.47-38 - Valves and closing appliances.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.47-38 Section 78.47-38 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-38 Valves and closing appliances. (a) All valves and...

  1. 40 CFR 61.242-7 - Standards: Valves.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Standards: Valves. 61.242-7 Section 61... (Fugitive Emission Sources) § 61.242-7 Standards: Valves. (a) Each valve shall be monitored monthly to...) If an instrument reading of 10,000 ppm or greater is measured, a leak is detected. (c)(1) Any...

  2. 30 CFR 56.16006 - Protection of gas cylinder valves.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of gas cylinder valves. 56.16006 Section 56.16006 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage and Handling § 56.16006 Protection of gas cylinder valves. Valves on compressed gas...

  3. 46 CFR 185.608 - Fuel shutoff valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fuel shutoff valves. 185.608 Section 185.608 Shipping...) OPERATIONS Markings Required § 185.608 Fuel shutoff valves. Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve...

  4. 49 CFR 192.179 - Transmission line valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission line valves. 192.179 Section 192.179... line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing block valves spaced as follows, unless in a particular case the Administrator finds that alternative...

  5. 46 CFR 154.1846 - Relief valves: Changing set pressure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Relief valves: Changing set pressure. 154.1846 Section... Relief valves: Changing set pressure. The master shall: (a) Supervise the changing of the set pressure of relief valves under § 154.802(b); (b) Enter the change of set pressure in the vessel's log; and...

  6. 30 CFR 57.16006 - Protection of gas cylinder valves.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of gas cylinder valves. 57.16006 Section 57.16006 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Storage and Handling § 57.16006 Protection of gas cylinder valves. Valves on compressed gas...

  7. 46 CFR 108.443 - Controls and valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Controls and valves. 108.443 Section 108.443 Shipping... valves. (a) At least one control for operating a CO2 system must be outside the space or spaces that the... system protects. Control valves must not be located in a protected space unless the CO2 cylinders...

  8. 46 CFR 109.333 - Fire main cutoff valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire main cutoff valves. 109.333 Section 109.333... OPERATIONS Operation and Stowage of Safety Equipment § 109.333 Fire main cutoff valves. The master or person in charge shall insure that each fire main cutoff valve is open and sealed to prevent closing,...

  9. 33 CFR 183.528 - Fuel stop valves.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel stop valves. 183.528 Section...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.528 Fuel stop valves. (a) Each electrically operated fuel stop valve in a fuel line between the fuel tank and the...

  10. 49 CFR 192.365 - Service lines: Location of valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Service lines: Location of valves. 192.365 Section..., and Service Lines § 192.365 Service lines: Location of valves. (a) Relation to regulator or meter. Each service-line valve must be installed upstream of the regulator or, if there is no...

  11. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve holder. 870.3935 Section 870.3935 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold...

  12. Incidental necropsy finding of a quadricuspid aortic valve

    NARCIS (Netherlands)

    van Rijswijk, Jan Willem; Willemink, Martin; Kluin, Jolanda; Vink, Aryan

    2015-01-01

    Quadricuspid aortic valve is a rare congenital cardiac malformation often associated with abnormal valve function. In this article, we present a case of quadricuspid aortic valve only diagnosed at the time of post-mortem examination. (C) 2015 Elsevier Inc. All rights reserved.

  13. Three-dimensional echocardiography of a tricuspid valve papillary fibroelastoma

    Directory of Open Access Journals (Sweden)

    Atooshe Rohani

    2017-01-01

    Full Text Available Papillary fibroelastomas (PFE on tricuspid valve (TV are rare, accounting for fewer than 11% of all PFE. Most often they are asymptomatic, and detect on mitral valve. We report a case of a typical chest pain found to be due to papillary fibroelastoma of the tricuspid valve.

  14. A Bast-like valve in the pigeon?

    NARCIS (Netherlands)

    Hofman, Rutger; Segenhout, J. M.; Wit, H. P.

    2009-01-01

    The first description of the presence of a utriculo-endolymphatic valve in human fetuses was given by Bast in 1928. Since then this valve-like structure is called Bast's valve. Its exact function has not yet been established. The general opinion is that it has a protective function by having the pos

  15. Iterative Learning of Transcatheter Mitral Valve Replacement in Mitral Valve Annulus Calcification: Management and Prevention of Transcatheter Mitral Valve Replacement Dislocation.

    Science.gov (United States)

    Hulman, Michal; Bena, Martin; Artemiou, Panagiotis; Gasparovic, Ivo; Hudec, Vladan; Rajani, Ronak; Bapat, Vinayak

    2016-10-01

    Transcatheter mitral valve replacement using balloon-expandable valves is an emerging technique for the treatment of patients with significant mitral regurgitation who have been judged to be inoperable owing to significant mitral valve annulus calcification. Although initial reports have been promising, there remains a lack of consensus as to how to plan for transcatheter mitral valve replacement deployment in terms of appropriateness, sizing, and positioning to mitigate the risks of valve displacement and paravalvular regurgitation. We describe two cases of transcatheter mitral valve replacement in patients with significant mitral valve annulus calcification. The first was complicated by valve displacement into the left atrium, which was successfully managed by surgical redeployment and fixation. The second case was thereafter performed successfully using iterative learning and the application of specific preprocedural planning techniques acquired from a root cause analysis of the first case. We describe our experience with both cases and the specific planning principles required to prevent transcatheter mitral valve replacement displacement in patients with mitral valve annulus calcification.

  16. Preservation versus non-preservation of mitral valve apparatus during mitral valve replacement: a meta-analysis of 3835 patients.

    Science.gov (United States)

    Sá, Michel Pompeu Barros de Oliveira; Ferraz, Paulo Ernando; Escobar, Rodrigo Renda; Martins, Wendell Santos; de Araújo e Sá, Frederico Browne Correia; Lustosa, Pablo César; Vasconcelos, Frederico Pires; Lima, Ricardo Carvalho

    2012-12-01

    Resection of the chordopapillary apparatus during mitral valve replacement has been associated with a negative impact on survival. Mitral valve replacement with the preservation of the mitral valve apparatus has been associated with better outcomes, but surgeons remain refractory to its use. To determine if there is any real difference in preservation vs non-preservation of mitral valve apparatus during mitral valve replacement in terms of outcomes, we performed a systematic review and meta-analysis using MEDLINE, EMBASE, CENTRAL/CCTR, SciELO, LILACS, Google Scholar and reference lists of relevant articles to search for clinical studies that compared outcomes (30-day mortality, postoperative low cardiac output syndrome or 5-year mortality) between preservation vs non-preservation during mitral valve replacement from 1966 to 2011. The principal summary measures were odds ratios (ORs) with 95% confidence interval and P-values (that will be considered statistically significant when mitral valve replacement preservation and 1917 for mitral valve replacement non-preservation). There was significant difference between mitral valve replacement preservation and mitral valve replacement non-preservation groups in the risk of 30-day mortality (OR 0.418, P mitral valve apparatus during mitral valve replacement.

  17. Interleukin-37 suppresses the osteogenic responses of human aortic valve interstitial cells in vitro and alleviates valve lesions in mice

    NARCIS (Netherlands)

    Zeng, Q.; Song, R.; Fullerton, D.A.; Ao, L.; Zhai, Y.; Li, S.; Ballak, D.B.; Cleveland, J.C., Jr.; Reece, T.B.; McKinsey, T.A.; Xu, D.; Dinarello, C.A.; Meng, X.

    2017-01-01

    Calcific aortic valve disease is a chronic inflammatory process, and aortic valve interstitial cells (AVICs) from diseased aortic valves express greater levels of osteogenic factors in response to proinflammatory stimulation. Here, we report that lower cellular levels of IL-37 in AVICs of diseased h

  18. 40 CFR 60.483-1a - Alternative standards for valves-allowable percentage of valves leaking.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Alternative standards for valves-allowable percentage of valves leaking. 60.483-1a Section 60.483-1a Protection of Environment ENVIRONMENTAL...-1a Alternative standards for valves—allowable percentage of valves leaking. (a) An owner or...

  19. Image-guided transapical aortic valve implantation: sensorless tracking of stenotic valve landmarks in live fluoroscopic images.

    Science.gov (United States)

    Merk, Denis R; Karar, Mohamed Esmail; Chalopin, Claire; Holzhey, David; Falk, Volkmar; Mohr, Friedrich W; Burgert, Oliver

    2011-07-01

    Aortic valve stenosis is one of the most frequently acquired valvular heart diseases, accounting for almost 70% of valvular cardiac surgery. Transapical transcatheter aortic valve implantation has recently become a suitable minimally invasive technique for high-risk and elderly patients with severe aortic stenosis. In this article, we aim to automatically define a target area of valve implantation, namely, the area between the coronary ostia and the lowest points of two aortic valve cusps. Therefore, we present a new image-based tracking method of these aortic landmarks to assist in the placement of aortic valve prosthesis under live 2D fluoroscopy guidance. We propose a rigid intensity-based image registration technique for tracking valve landmarks in 2D fluoroscopic image sequences, based on a real-time alignment of a contrast image including the initialized manual valve landmarks to each image of sequence. The contrast image is automatically detected to visualize aortic valve features when the aortic root is filled with a contrast agent. Our registration-based tracking method has been retrospectively applied to 10 fluoroscopic image sequences from routine transapical aortic valve implantation procedures. Most of all tested fluoroscopic images showed a successful tracking of valve landmarks, especially for the images without contrast agent injections. A new intraoperative image-based method has been developed for tracking aortic valve landmarks in live 2D fluoroscopic images to assist transapical aortic valve implantations and to increase the overall safety of surgery as well.

  20. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses

    DEFF Research Database (Denmark)

    Seiffert, Moritz; Conradi, Lenard; Baldus, Stephan

    2012-01-01

    Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis...

  1. A Clinicopathological Study on Aortic Valves in Children

    Institute of Scientific and Technical Information of China (English)

    HUANG Ping; WANG Hongwei; ZHANG Zhenlu; HU Xiufen; LI Yanping; CHENG Peixuan; LIU Jianying

    2007-01-01

    In order to investigate the clinicopathological characteristics of aortic valve disease in children, all the native surgically excised aortic valves obtained between January 2003 and December 2005 were studied macroscopically and microscopically. The patients' medical records were reviewed and the clinical information was extracted. According to preoperative echocardiography, intraoperative assessment, and postoperative pathology, combined with clinical symptoms and signs, aortic valve diseases were divided into three categories: aortic stenosis (AS), aortic insufficiency (AI), and aortic stenosis with insufficiency (AS-AI). The etiology was determined according to the macroscopic, microscopic and clinical findings. The results showed that among 70 aortic valves, patient age ranged from 6 to 18 years, with a mean of 15.4 years, and there were 56 boys and 14 girts (male: female=4:1). Forty-four children only had pure aortic valve disease, and the other 26 children had aortic valve disease associated with other heart valve diseases. There were 5 cases of AS (7.14%), 60 cases of AI (85.71%) and 5 cases of AS-AI (7.14%). The causes were congenital aortic valve malformation (32 cases, 45.71%), rheumatic disease (28 cases, 40%), infective endocarditis (7 cases,10%), Marfan syndrome (2 cases, 2.86%), and undetermined (1 case, 1.43%). It was concluded that the common causes of aortic valve disease in order of frequency in children were congenital aortic valve malformation, rheumatic disease, infective endocarditis, and Marfan syndrome. AI was more common in children with aortic valve disease. Compared with adult patients, congenital bicuspid aortic valve in children was often AI. Histologically, the leaflets of congenital bicuspid aortic valve were mainly myxomatous, fibrosis and calcification less seen. AI was frequently found in rheumatic disease, mostly associated with other heart valve diseases. Macroscopic and microscopic examinations together with clinical

  2. Echocardiographic variables associated with mitral regurgitation after aortic valve replacement for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Shaimaa A. Mostafa

    2013-06-01

    Conclusion: Preoperative predictors of residual postoperative MR were large LA and AF while the postoperative variables were high peak and mean pressure gradient across the aortic valve and high LVMI.

  3. Valves replacement operation in treatment of electrical storm induced by rheumatic valves disease

    Institute of Scientific and Technical Information of China (English)

    Zhenqiang Chen; Hui Zhang; Yang Zhao; Haiji Yang; Sheng'ai Ye; Liang Cheng; Ying Zhang

    2007-01-01

    Objective: To present a case of electrical storm (ES) in a female patient with rheumatic valve disease. Methods: A female patient with severe rheumatic valve disease suffered an unexpected ES. She received more than 50 electrical shocks for repeated cardiac arrests due to ES over 16 hours. Then she received beta-blocking agent treatment and had an operation of double valves replacement. Results: ES was suppressed by sympathetic blockade with beta-receptor blocker and finally disappeared after the double pathological valves had been replaced. Conclusion: Increased sympathetic activity plays an important role in the genesis of electrical storm and sympathetic blockade may effectively suppress ES. However, the most important thing in the treatment of ES is to identify and eliminate the underlying cause of ES.

  4. [Middle third of the nose and internal valve. Alar wall and external valve].

    Science.gov (United States)

    Duron, J B; Nguyen, P S; Jallut, Y; Bardot, J; Aiach, G

    2014-12-01

    To many surgeons, nasal airway obstruction is synonymous with either septal deviation or inferior turbinate hypertrophy. The role of internal and external nasal valves is often less known by surgeons even if it is crucial in nasal breathing and strongly interrelated with esthetic of the middle third of the nose and alar wall. Therefore, precise examination of the two valves and conservative surgery should help to avoid many functional and esthetic problems. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. Structural valve deterioration after aortic valve replacement with Medtronic freestyle stentless porcine aortic root bioprostheses.

    Science.gov (United States)

    Nishida, Hidefumi; Komiya, Tatsuhiko; Sakaguchi, Genichi; Shimamoto, Takeshi

    2014-01-01

    The Medtronic freestyle aortic root bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA) is a stentless valve with an effective orifice area that is larger than that observed on other bioprostheses. However, there have been sporadic reports of structural valve deterioration (SVD), such as aortic root wall rupture, leaflet tearing, and pseudoaneurysm formation. We report five cases of SVD of freestyle aortic root bioprostheses. © 2013 The Authors. Journal of Cardiac Surgery Published by Wiley Periodicals, Inc.

  6. The warm, rich sound of valve guitar amplifiers

    Science.gov (United States)

    Keeports, David

    2017-03-01

    Practical solid state diodes and transistors have made glass valve technology nearly obsolete. Nevertheless, valves survive largely because electric guitar players much prefer the sound of valve amplifiers to the sound of transistor amplifiers. This paper discusses the introductory-level physics behind that preference. Overdriving an amplifier adds harmonics to an input sound. While a moderately overdriven valve amplifier produces strong even harmonics that enhance a sound, an overdriven transistor amplifier creates strong odd harmonics that can cause dissonance. The functioning of a triode valve explains its creation of even and odd harmonics. Music production software enables the examination of both the wave shape and the harmonic content of amplified sounds.

  7. Minimally Invasive Transaortic Mitral Decalcification During Aortic Valve Replacement.

    Science.gov (United States)

    Totsugawa, Toshinori; Sakaguchi, Taichi; Hiraoka, Arudo; Matsushita, Hiroshi; Hirai, Yuki; Yoshitaka, Hidenori

    2015-01-01

    Mitral annular calcification accompanied by aortic stenosis is hazardous for both double-valve replacement and transcatheter aortic valve implantation. Less invasive mitral procedure is required in this condition, and minimally invasive approach may further reduce the operative risk in high-risk patients. Here, we report minimally invasive transaortic mitral decalcification during aortic valve replacement through minithoracotomy. We believe that this option is feasible in patients who are at prohibitive risk for double-valve replacement or transcatheter aortic valve implantation because of severe mitral annular calcification.

  8. Valve exploiting the principle of a side channel turbine

    Directory of Open Access Journals (Sweden)

    Jandourek Pavel

    2017-01-01

    Full Text Available The article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Reducing valves are a source of hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the valve and the turbine. The basis for the design is the loss characteristics of the valve. Thereby creating a kind of turbine valve with speed-controlled flow in dependence of runner revolution.

  9. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  10. The tricuspid valve in adult congenital heart disease.

    Science.gov (United States)

    Ginns, Jonathan; Ammash, Naser; Bernier, Pierre-Luc

    2014-01-01

    The tricuspid valve is frequently affected in adults with congenital heart disease but is also frequently overlooked. Disease of this valve can occur primarily or develop secondary to changes in the right ventricle caused by other disease states. The embryology and anatomy of the tricuspid valve are important to understanding pathogenesis of valve dysfunction in congenital heart disease. Clinical findings can be subtle. Multimodality imaging may be necessary to fully assess the cause and impact of tricuspid valve lesions. More research is needed in pathophysiology, imaging, and treatment in this area. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Space Shuttle OMS engine valve technology. [Orbital Maneuvering System

    Science.gov (United States)

    Wichmann, H.

    1974-01-01

    Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

  12. [Fluid solid interaction analysis of bioprosthetic heart valve].

    Science.gov (United States)

    Ma, Xuejie; Du, Yawei; Zhang, Linan; Hou, Zengtao; Ye, Xin

    2014-09-01

    This paper constructs numerical models of bioprosthetic heart valve and blood. The fluid solid interaction is carried out using penalty function method. The mechanical property of the bioprosthetic heart valve during cardiac cycle is simulated with ANSYS software. Results show that the Von Mises stress concentrates at the junction of attachment edge and coaptation edge. The open time of bioprosthetic heart valve is consistent with that of actural measurement. The peak velocity of blood is in the range of physiology. This model provides more realistic mechanical property of bioprosthetic heart valve during cardiac cycle compared to pure solid model, and facilitates design and optimization of bioprosthetic heart valve.

  13. Severe aortic valve stenosis and nosebleed

    NARCIS (Netherlands)

    Schoedel, Johannes; Obergfell, Achim; Maass, Alexander H.; Schodel, Johannes

    2007-01-01

    Aortic valve stenosis is known to be associated with loss of high molecular von Willebrand multimers. This can lead to gastrointestinal bleeding in patients with gastrointestinal angiodysplasia, the Heyde syndrome. Here we present a case of anaemia and severe epistaxis associated with acquired von W

  14. Diaphragms in air-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Groeger, J.E.

    1996-12-01

    The author will present current issues related to diaphgrams in air-operated valves. Altran Materials Engineering, Inc., often performs root-cause analyses for nuclear power plant owners. The author will discuss various analyses that have been performed or are currently underway.

  15. Aortic Valve Replacement in Young Adults

    NARCIS (Netherlands)

    L.M.A. Klieverik (Loes Maria Anne)

    2007-01-01

    textabstractWorldwide the incidence and burden of heart valve disease is increasing due to aging of the world population and the problem of rheumatic cardiac disease in developing countries and in parts of the population in the developed world.1 Between 2007 and 2050 the world population will increa

  16. A Maxwellian Valve based on centrifugal forces

    Directory of Open Access Journals (Sweden)

    Lyndsay G.M. Gordon

    2004-03-01

    Full Text Available Abstract: A mechanism is described which can create a chemical potential gradient from a single heat reservoir. The mechanism is equivalent to a Maxwellian valve. Heat supplies the energy through thermal fluctuations to form the gradient contrary to the second law. A quantitative analysis of the system is given.

  17. Minimally invasive "pocket incision" aortic valve surgery.

    Science.gov (United States)

    Yakub, M A; Pau, K K; Awang, Y

    1999-02-01

    A minimally invasive approach to aortic valve surgery through a transverse incision ("pocket incision") at the right second intercostal space was examined. Sixteen patients with a mean age of 30 years underwent this approach. The third costal cartilage was either excised (n = 5) or dislocated (n = 11). The right internal mammary artery was preserved. Cardiopulmonary bypass (CPB) was established with aortic-right atrial cannulation in all except the first case. Aortic valve replacements (AVR) were performed in 15 patients and one had aortic valve repair with concomitant ventricular septal defect closure. There was no mortality and no major complications. The aortic cross-clamp, CPB and operative times were 72 +/- 19 mins, 105 +/- 26 mins and 3 hrs 00 min +/- 29 mins respectively. The mean time to extubation was 5.7 +/- 4.0 hrs, ICU stay of 27 +/- 9 hrs and postoperative hospital stay of 5.1 +/- 1.2 days. Minimally invasive "pocket incision" aortic valve surgery is technically feasible and safe. It has the advantages of central cannulation for CPB, preservation of the internal mammary artery and avoiding sternotomy. This approach is cosmetically acceptable and allows rapid patient recovery.

  18. Multimodality Imaging Assessment of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Suchá, D.; Symersky, Petr; Tanis, W; Mali, Willem P Th M; Leiner, Tim; van Herwerden, LA; Budde, Ricardo P J

    2015-01-01

    Echocardiography and fluoroscopy are the main techniques for prosthetic heart valve (PHV) evaluation, but because of specific limitations they may not identify the morphological substrate or the extent of PHV pathology. Cardiac computed tomography (CT) and magnetic resonance imaging (MRI) have emerg

  19. Enteroenteroanastomosis near adjacent ileocecal valve in infants

    Institute of Scientific and Technical Information of China (English)

    Wei-Wei Jiang; Xiao-Qun Xu; Qi-Ming Geng; Jie Zhang; Huan Chen; Xiao-Feng Lv; Chang-Gui Lu

    2012-01-01

    AIM:To investigate the feasibility and the effectiveness of ileoileostomy in the region adjacent to the ileocecal valve,which can retain the ileocecal valve in infants.METHODS:This is a retrospective review of 48 patients who underwent ileoileostomy in the region adjacent to the ileocecal valve (group 1) and 34 patients who underwent ileocecal resections and ileotransversanastomosis (group 2).Patients were monitored for the time to flatus,resumption of eating,length of hospital stay after surgery,serum total bile acid,vitamin B12 and postoperative complications.RESULTS:The time to flatus,time until resumption of eating and post-operative length of hospital stay showed no statistically significant differences between the two groups.Serum total bile acid and vitamin B12 were not significantly different between the two groups at post-operative day 1 and day 3,but were significantly decreased at 1 wk after operation in group 2.None of the patients died or suffered from stomal leak in these two groups.However,the incidence of diarrhea,intestinal infection,disturbance of acid-base balance and water-electrolytes in group 1 was lower than in group 2.CONCLUSION:Ileoileostomy in the region adjacent to the ileocecal valve is safe and results in fewer complications than ileotransversanastomosis in infants.

  20. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  1. Transcatheter aortic valve implantation: status and challenges.

    Science.gov (United States)

    Fishbein, Gregory A; Schoen, Frederick J; Fishbein, Michael C

    2014-01-01

    Calcific aortic valve disease of the elderly is the most prevalent hemodynamically-significant valvular disease, and the most common lesion requiring valve replacement in industrialized countries. Transcatheter aortic valve implantation is a less invasive alternative to classical aortic valve replacement that can provide a therapeutic option for high-risk or inoperable patients with aortic stenosis. These devices must be biocompatible, have excellent hemodynamic performance, be easy to insert, be securely anchored without sutures, and be durable, without increased risk of thrombosis or infection. To date, complications are related to the site of entry for insertion, the site of implantation (aorta, coronary ostia, base of left ventricle), and to the structure and design of the inserted device. However, as with any novel technology unanticipated complications will develop. Goals for future development will be to make the devices more effective, more durable, safer, and easier to implant, so as to further improve outcome for patients with severe aortic stenosis. The pathologist participating in research and development, and examination of excised devices will have a critical role in improving outcome for these patients.

  2. Interlayer quality dependent graphene spin valve

    Science.gov (United States)

    Iqbal, Muhammad Zahir; Hussain, Ghulam; Siddique, Salma; Iqbal, Muhammad Waqas; Murtaza, Ghulam; Ramay, Shahid Mahmood

    2017-01-01

    It is possible to utilize the new class of materials for emerging two-dimensional (2D) spintronic applications. Here, the role of defects in the graphene interlayer and its influence on the spin valve signal is reported. The emergence of D peak in Raman spectrum reveals defects in the graphene layer. The linear I-V curve for defective and non-defective graphene samples indicate the ohmic nature of NiFe and graphene contact. A non-uniform magnetoresistive effect with a bump is persistently observed for defective graphene device at various temperatures, while a smooth and symmetric signal is detected for non-defective graphene spin valve. Parallel and antiparallel alignments of magnetization of magnetic materials shows low and high resistance states, respectively. The magnetoresistance (MR) ratio for defective graphene NiFe/graphene/NiFe spin valve is measured to be 0.16% at 300 K which progresses to 0.39% for non-defective graphene device at the same temperature. Similarly at 4.2 K the MR ratios are reported to be 0.41% and 0.78% for defective and non-defective graphene devices, respectively. Our investigation provides an evidence for relatively better response of the spin valve signal with high quality graphene interlayer.

  3. Ventriculopleural shunting with new technology valves.

    Science.gov (United States)

    Martínez-Lage, J F; Torres, J; Campillo, H; Sanchez-del-Rincón, I; Bueno, F; Zambudio, G; Poza, M

    2000-12-01

    Ventriculoperitoneal shunting constitutes the standard procedure for draining cerebrospinal fluid (CSF) in children with hydrocephalus. Ventriculoatrial and ventriculopleural shunting are alternative methods of CSF drainage, which have gained less acceptance. Ventriculopleural shunts are seldom used owing to justified fears of pneumothorax and symptomatic effusions of CSF. The addition of an antisiphon device to standard shunt systems seems to have prevented CSF pleural effusion. From 1988 to 1998, we treated each of six hydrocephalic children with a ventriculopleural shunt. In five cases we used new-technology valves designed to prevent the effects of siphoning with current differential pressure valves. Peritoneal adhesions, recent peritonitis, ascites, and obstruction of a previous ventriculoatrial shunt were the indications for pleural shunting. After a mean follow-up period of 2.5 years all shunts were functioning adequately. Only one patient showed transient symptoms of CSF overdrainage, which were corrected by up-grading the valve setting with the magnet. A late death was unrelated to the pleural shunting procedure. The use of valves of a new design designed to prevent overdrainage seems to account for the satisfactory outcomes observed in this series. We suggest that ventriculopleural shunting should be considered as the preferred alternative to peritoneal drainage in children with intra-abdominal adhesions or with a history of recent peritoneal infection.

  4. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    development process and mixed clinical results with these novel technologies. This review aims to discuss the several anatomical aspects and challenges related to transcatheter mitral valve intervention - the relevant anatomy will be reviewed in relation to specific requirements for device design...

  5. Tubular heart valves from decellularized engineered tissue.

    Science.gov (United States)

    Syedain, Zeeshan H; Meier, Lee A; Reimer, Jay M; Tranquillo, Robert T

    2013-12-01

    A novel tissue-engineered heart valve (TEHV) was fabricated from a decellularized tissue tube mounted on a frame with three struts, which upon back-pressure cause the tube to collapse into three coapting "leaflets." The tissue was completely biological, fabricated from ovine fibroblasts dispersed within a fibrin gel, compacted into a circumferentially aligned tube on a mandrel, and matured using a bioreactor system that applied cyclic distension. Following decellularization, the resulting tissue possessed tensile mechanical properties, mechanical anisotropy, and collagen content that were comparable to native pulmonary valve leaflets. When mounted on a custom frame and tested within a pulse duplicator system, the tubular TEHV displayed excellent function under both aortic and pulmonary conditions, with minimal regurgitant fractions and transvalvular pressure gradients at peak systole, as well as well as effective orifice areas exceeding those of current commercially available valve replacements. Short-term fatigue testing of one million cycles with pulmonary pressure gradients was conducted without significant change in mechanical properties and no observable macroscopic tissue deterioration. This study presents an attractive potential alternative to current tissue valve replacements due to its avoidance of chemical fixation and utilization of a tissue conducive to recellularization by host cell infiltration.

  6. Aortic valve surgery: what is the future?

    Science.gov (United States)

    Hudorović, Narcis

    2008-04-01

    Modern surgical treatment for aortic valve disease has undergone significant improvements in all areas of this procedure. Successful treatment strategies for cardiovascular diseases have often been initiated and driven by surgeons. Radical excision of diseased tissue, repair and replacement strategies lead to long-term successful treatment of the underlying diseases and clearly improved patient outcome. In highly developed nations, valve surgery will be increasing applied in older people, with more co-morbidities and a higher incidence of concomitant coronary artery disease. Cardiovascular surgeons will be facing increased competition from the catheter-based procedures; these are already applied clinically, and their numbers will rise in near future. Right now interventional cardiologists supported by some cardiac surgeons are on their way to transform some conventional open surgical procedures into catheter-based less invasive interventions, such as valve repair and replacement. Cardiovascular surgery is undergoing a rapid transformation; socio-economic factors and recent advances in medical technology contribute to these changes. Further developments will come, and surgeons with all their expertise in the treatment of valvular heart disease need to be part of it. Cardiovascular surgeons have to adapt the exciting new approaches of transapical and transfemoral transcatheter valve implantation techniques.

  7. Enteroenteroanastomosis near adjacent ileocecal valve in infants

    Science.gov (United States)

    Jiang, Wei-Wei; Xu, Xiao-Qun; Geng, Qi-Ming; Zhang, Jie; Chen, Huan; Lv, Xiao-Feng; Lu, Chang-Gui; Tang, Wei-Bing

    2012-01-01

    AIM: To investigate the feasibility and the effectiveness of ileoileostomy in the region adjacent to the ileocecal valve, which can retain the ileocecal valve in infants. METHODS: This is a retrospective review of 48 patients who underwent ileoileostomy in the region adjacent to the ileocecal valve (group 1) and 34 patients who underwent ileocecal resections and ileotransversanastomosis (group 2). Patients were monitored for the time to flatus, resumption of eating, length of hospital stay after surgery, serum total bile acid, vitamin B12 and postoperative complications. RESULTS: The time to flatus, time until resumption of eating and post-operative length of hospital stay showed no statistically significant differences between the two groups. Serum total bile acid and vitamin B12 were not significantly different between the two groups at post-operative day 1 and day 3, but were significantly decreased at 1 wk after operation in group 2. None of the patients died or suffered from stomal leak in these two groups. However, the incidence of diarrhea, intestinal infection, disturbance of acid-base balance and water-electrolytes in group 1 was lower than in group 2. CONCLUSION: Ileoileostomy in the region adjacent to the ileocecal valve is safe and results in fewer complications than ileotransversanastomosis in infants. PMID:23326139

  8. Giant magnetoresistance in organic spin-valves.

    Science.gov (United States)

    Xiong, Z H; Wu, Di; Vardeny, Z Valy; Shi, Jing

    2004-02-26

    A spin valve is a layered structure of magnetic and non-magnetic (spacer) materials whose electrical resistance depends on the spin state of electrons passing through the device and so can be controlled by an external magnetic field. The discoveries of giant magnetoresistance and tunnelling magnetoresistance in metallic spin valves have revolutionized applications such as magnetic recording and memory, and launched the new field of spin electronics--'spintronics'. Intense research efforts are now devoted to extending these spin-dependent effects to semiconductor materials. But while there have been noteworthy advances in spin injection and detection using inorganic semiconductors, spin-valve devices with semiconducting spacers have not yet been demonstrated. pi-conjugated organic semiconductors may offer a promising alternative approach to semiconductor spintronics, by virtue of their relatively strong electron-phonon coupling and large spin coherence. Here we report the injection, transport and detection of spin-polarized carriers using an organic semiconductor as the spacer layer in a spin-valve structure, yielding low-temperature giant magnetoresistance effects as large as 40 per cent.

  9. Autopsy after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    van Kesteren, F; Wiegerinck, E M A; Rizzo, S

    2017-01-01

    Autopsy after transcatheter aortic valve implantation (TAVI) is a new field of interest in cardiovascular pathology. To identify the cause of death, it is important to be familiar with specific findings related to the time interval between the procedure and death. We aimed to provide an overview...

  10. Conservative aortic valve surgery in adults

    NARCIS (Netherlands)

    Casselman, F.P.A.

    2001-01-01

    118 Chapter 1 reviews the current knowledge of the aortic valve. The normal anatomy and possible variations are described. The different pathological conditions are explained as wel as their natural history and the indications for intervention. The various surgical options with regard to the patholo

  11. Tricuspid regurgitation after successful mitral valve surgery.

    Science.gov (United States)

    Katsi, Vasiliki; Raftopoulos, Leonidas; Aggeli, Constantina; Vlasseros, Ioannis; Felekos, Ioannis; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Kallikazaros, Ioannis

    2012-07-01

    The tricuspid valve (TV) is inseparably connected with the mitral valve (MV) in terms of function. Any pathophysiological condition concerning the MV is potentially a threat for the normal function of the TV as well. One of the most challenging cases is functional tricuspid regurgitation (TR) after surgical MV correction. In the past, TR was considered to progressively revert with time after left-sided valve restoration. Nevertheless, more recent studies showed that TR could develop and evolve postoperatively over time, as well as being closely associated with a poorer prognosis in terms of morbidity and mortality. Pressure and volume overload are usually the underlying pathophysiological mechanisms; structural alterations, like tricuspid annulus dilatation, increased leaflet tethering and right ventricular remodelling are almost always present when regurgitation develops. The most important risk factors associated with a higher probability of late TR development involve the elderly, female gender, larger left atrial size, atrial fibrillation, right chamber dilatation, higher pulmonary artery systolic pressures, longer times from the onset of MV disease to surgery, history of rheumatic heart disease, ischaemic heart disease and prosthetic valve malfunction. The time of TR manifestation can be up to 10 years or more after an MV surgery. Echocardiography, including the novel 3D Echo techniques, is crucial in the early diagnosis and prognosis of future TV disease development. Appropriate surgical technique and timing still need to be clarified.

  12. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2011-03-01

    The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range.

  13. Molecular valves actuated by intermolecular forces.

    Science.gov (United States)

    Snyder, M A; Vlachos, D G

    2005-06-01

    Phase behavior in nanostructured thin films under a gradient in chemical potential is studied via kinetic Monte Carlo simulation. Switching between saturated, partially saturated, and unsaturated states drives precipitous changes in permeation. This phenomenon could render nanostructured thin films as molecular valves, where adsorbate-adsorbate forces actuate the flow of molecules.

  14. Early postpartum mitral valve thrombosis requiring extra corporeal membrane oxygenation before successful valve replacement.

    Science.gov (United States)

    Halldorsdottir, H; Nordström, J; Brattström, O; Sennström, M M; Sartipy, U; Mattsson, E

    2016-05-01

    Pregnancy is associated with an increased risk of thrombosis in women with mechanical prosthetic heart valves. We present the case of a 29-year-old woman who developed early postpartum mitral valve thrombus after an elective cesarean delivery. The patient had a mechanical mitral valve and was treated with warfarin in the second trimester, which was replaced with high-dose dalteparin during late pregnancy. Elective cesarean delivery was performed under general anesthesia at 37weeks of gestation. The patient was admitted to the intensive care unit for postoperative care and within 30min she developed dyspnea and hypoxia requiring mechanical ventilation. She deteriorated rapidly and developed pulmonary edema, worsening hypoxia and severe acidosis. Urgent extra corporeal membrane oxygenation was initiated. Transesophageal echocardiography revealed a mitral valve thrombus. The patient underwent a successful mitral valve replacement after three days on extra corporeal membrane oxygenation. This case highlights the importance of multidisciplinary care and frequent monitoring of anticoagulation during care of pregnant women with prosthetic heart valves.

  15. Patient outcome and valve performance following a second aortic valve homograft replacement.

    Science.gov (United States)

    Hasnat, K; Birks, E J; Liddicoat, J; Hon, J K; Edwards, S; Glennon, S; Yacoub, M H

    1999-11-09

    Homograft valves offer many advantages; however, there is concern about their use in second aortic valve replacement because of the complexity of the procedure and the possibility of accelerated degeneration. One hundred and forty-four patients underwent a second aortic homograft replacement between 1973 and 1997 (mean follow-up 6.5+/-5 years, range 1 to 20 years). Eighty-three were male, and 61 were female, aged 17 to 77 years, mean 49.0 years. All patients had undergone previous aortic valve replacement with a homograft. The indication for reoperation was aortic regurgitation in 75 patients (52.1%), aortic stenosis in 28 (19.4%), and mixed aortic valve disease in 41 (28.5%). Root replacement was performed in 54 patients (38%) and subcoronary in 90 (62.5%). Early mortality was 3.4%. The actuarial survival rate was 93% and 82% at 5 and 10 years, respectively. Freedom from tissue degeneration was 96% and 80% at 5 and 10 years, respectively, and freedom from reoperation was 97% and 82% at 5 and 10 years, respectively. This study shows that a second aortic valve homograft replacement results in good early and long-term survival. Accelerated degeneration does not occur. Left ventricular performance is improved, and earlier surgery could further improve outcome, indicating that an aortic homograft is a safe, durable option for patients requiring a second aortic valve replacement.

  16. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  17. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  18. Optimization of Valve Disc Using Orthogonal Array and Kriging Model

    Science.gov (United States)

    Song, Xueguan; Wang, Lin; Kang, Jungho; Kim, Seung Gyu; Jo, Young Jik; Park, Youngchul

    2008-10-01

    A butterfly valve is a type of flow control device, typically used to regulate a fluid flowing. Currently, FEA is often used to predict the safety in the design of valve disc. Also, the study about the affection of butterfly valve's disc to the valve flow characteristics by using CFD has been done by many researchers. Along with the development of computer technique, design and analysis of computer experiments has becoming more and more important in engineering design and optimization. Hereinto Kriging model is one popular analysis approach for the purpose of creating a cheap "meta-model" as a surrogate to a computationally expensive simulation model. In this paper, the numerical analysis considered the strength, pressure loss coefficient and weight of valve disc simultaneously is investigated to improve the shape of a traditional butterfly valve disc. Firstly, an initial model of butterfly valve is made to evaluate the performance of the valve disc by using CFD and FEM. Then several experiments with different variables combination of the valve disc are conducted by mean of orthogonal array. Finally, the Kriging model is used to find the optimum variables combination of valve disc based on the result of computer experiments. In addition, the optimum result is verified by FEA and CFD simulation again. The result shows that compared with traditional computer experiments, optimization by using Kriging model can improve the weight of the valve disc very effectively in a short time.

  19. Improved Relief Valve Would Be Less Susceptible to Failure

    Science.gov (United States)

    Farner, Bruce R.

    2008-01-01

    The balanced-piston relief valve with side vented reaction cavity has been proposed as an improved alternative to a conventional high-pressure, high-flow relief valve. The proposed valve would be less susceptible to failure. A typical conventional high-pressure, high-flow relief valve contains a piston that is exposed to the upstream pressure across the full valve-seat diameter and is held against the valve seat and the upstream pressure by a large spring. In the event of an increase in upstream pressure to a level above the valve set point (the pressure above which the valve opens), the opening force on the piston can be so large that the piston becomes accelerated to a speed high enough that the ensuing hard impact of the piston within the valve housing results in failure of the valve. For a given flow cross section, the proposal would significantly reduce the force, thereby reducing susceptibility to failure. A basic version of the proposed balanced-piston relief valve with side vented reaction cavity is described.

  20. A Tandem Valve, a unique complication of TAVR

    Directory of Open Access Journals (Sweden)

    Srinivasan Sattiraju

    2016-02-01

    Full Text Available , MD1*,, MD1,, MD1,, MD2, MD2,, MD, PhD3 1. Division of Cardiology, Carle Heart and Vascular Institute, Carle Hospital, Urbana, IL 2. Cardiovascular Surgery, Carle Heart and Vascular Institute, Carle Hospital, Urbana, IL 3. Division of Cardiology, University of Minnesota Medical Center, Minneapolis, MN Received: 11-1-16, Reviewed: 22-1-16, Accepted: 26-1-16 Keywords: Transcatheter aortic valve replacement, TAVR, Valve embolisation DOI: ABSTRACT We report a unique complication of transcatheter aortic valve replacement (TAVR in which there is mechanical entrapment of two Edward Sapien valves. The tandem valve con guration created a high gradient across the valves stuck in tandem. The images and videos in this case capture ndings that underscore the complexity of interaction between two prosthetic valves. We believe this case serves a high teaching value for physicians taking care of patients with aortic stenosis managed with TAVR approach.

  1. Reliability Evaluation of Concentric Butterfly Valve Using Statistical Hypothesis Test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Mu Seong; Choi, Jong Sik; Choi, Byung Oh; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2015-12-15

    A butterfly valve is a type of flow-control device typically used to regulate a fluid flow. This paper presents an estimation of the shape parameter of the Weibull distribution, characteristic life, and B10 life for a concentric butterfly valve based on a statistical analysis of the reliability test data taken before and after the valve improvement. The difference in the shape and scale parameters between the existing and improved valves is reviewed using a statistical hypothesis test. The test results indicate that the shape parameter of the improved valve is similar to that of the existing valve, and that the scale parameter of the improved valve is found to have increased. These analysis results are particularly useful for a reliability qualification test and the determination of the service life cycles.

  2. Numerical Analysis for Structural Safety Evaluation of Butterfly Valves

    Science.gov (United States)

    Shin, Myung-Seob; Yoon, Joon-Yong; Park, Han-Yung

    2010-06-01

    Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low operating pressure especially in large size pipelines. For the industrial application of butterfly valves, it must be ensured that the valve could be used safety under the fatigue life and the deformations produced by the pressure of the fluid. In this study, we carried out the structure analysis of the body and the valve disc of the butterfly valve and the numerical simulation was performed by using ANSYS v11.0. The reliability of valve is evaluated under the investigation of the deformation, the leak test and the durability of the valve.

  3. Apparatus comprising magnetically actuated valves and uses thereof

    Science.gov (United States)

    Edwards, Thayne L.; Harper, Jason C.

    2016-07-12

    The present invention, in part, relates to an apparatus having a single-use, normally-closed fluidic valve that is initially maintained in the closed position by a valve element bonded to an adhesive coating. The valve is opened using a magnetic force. The valve element includes a magnetic material or metal. In some examples, the valve is opened by bringing a magnet in proximity to the valve element to provide a magnetic force that delaminates the valve element from the adhesive coating. In particular, the apparatus can be useful for on-chip amplification and/or detection of various targets, including biological targets and any amplifiable targets. Such apparatuses and methods are useful for in-field or real-time detection of targets, especially in limited resource settings.

  4. Remote manual operator for space station intermodule ventilation valve

    Science.gov (United States)

    Guyaux, James R.

    1996-01-01

    The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

  5. [Three-dimensional reconstruction of heart valves].

    Science.gov (United States)

    Flachskampf, F A; Kühl, H; Franke, A; Frielingsdorf, J; Klues, H; Krebs, W; Hanrath, P

    1995-08-01

    The reconstruction of three-dimensional data sets from two-dimensional echocardiographic images offers several fundamental advantages: 1. more complete data than present in the few standard 2D-view; 2. off-line generation of any desired plane, cut, or perspective after the data set has been acquired; 3. access to quantitative parameters like surface areas (e.g., of valve leaflets or portions of leaflets), volumes, and others, without geometric assumptions. The mitral valve has been the focus of several studies using various techniques of reconstruction of transthoracic or transesophageal images. These studies have shown the mitral annulus to be a non-planar, "saddle-shaped" structure, with an average distance of highest to lowest points of 14 mm in normals. This recognition of mitral annular non-planarity has led to a more stringent echocardiographic definition of mitral valve prolapse. Further studies have shown systolic shrinkage of mitral annular area by about 30% and systolic apico-basal translation of the annulus by approximately 1 cm in normals. In patients with dilated cardiomyopathy, the annulus is flattened, and both cyclic change in annular area and apico-basal translation are significantly reduced. 3D-studies of the left ventricular outflow tract in hypertrophic obstructive cardiomyopathy allow measurement of outflow tract and leaflet surface areas and dynamic spatial visualization of systolic anterior motion of the anterior mitral leaflet. Automated techniques to reconstruct the full grey value data set from a high number of parallel or rotational transesophageal planes allow impressive visualization of normal and diseased mitral and aortic valves or valve prostheses, with special emphasis on generating "surgical" views and perspectives, which cannot be obtained by conventional tomographic imaging.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Double orifice mitral valve: A case report

    Directory of Open Access Journals (Sweden)

    Musić Ljilja

    2016-01-01

    Full Text Available Introduction. Double orifice mitrol valve (DOMV is a very rare congenital heart defect. Case report. We reported 20-year-old male referred to our center due to evaluation of his cardiologic status. He was operated on shortly after birth for a tracheoesophageal fistula. Accidentally, echocardiography examination at the age of 4 years revealed double orifice mitral valve (DOMV without the presence of mitral regurgitation, as well as mitral stenosis, with normal dimensions of all cardiac chambers. The patient was asymptomatic, even more he was a kick boxer. His physical finding was normal. Electrocardiography showed regular sinus rhythm, incomplete right bundle branch block. Transthoracic echocardiography (TTE examination revealed the normal size of the left atrial, mitral leaflets were slightly more redundant. The left and right heart chambers, aorta, tricuspid valve and pulmonary artery valve were normal. During TTE examination on a short axis view two asymmetric mitral orifices were seen as a double mitral orifice through which we registered normal flow, without regurgitation and mitral stenosis. Transesophageal echocardiography (TEE examination from the transgastric view at the level of mitral valve, showed 2 single asymmetric mitral orifices separated by fibrous tissue, mitral leaflet with a separate insertion of hordes for each orifice. Conclusion. The presented patient with DOMV is the only one recognized in our country. The case is interesting because during 16-year a follow-up period there were no functional changes despite the fact that he performed very demanded sport activities. This is very important because there is no information in the literature about that.

  7. [Research status and development trends of the heart valve mechanical properties].

    Science.gov (United States)

    Li, Yusheng; Zeng, Pei; Ren, Guorong

    2014-10-01

    The study of mechanical properties on heart valves can provide an important theoretical basis for doctors to repair heart valves and prosthetic valve materials research. In this paper, we present the current status of the mechanical property study methods of heart valve, expound the methods and special requirements about uniaxial tensile test and biaxial tensile test of the heart valve, and further discuss several establishment methods of heart valve constitutive models. We also discuss the development trend of heart valve mechanics.

  8. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    Energy Technology Data Exchange (ETDEWEB)

    Love, Lonnie J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mell, Ellen [Aerovalve, LLC, St. Louis, Mo (United States)

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  9. Absence of venous valves in mice lacking Connexin37.

    Science.gov (United States)

    Munger, Stephanie J; Kanady, John D; Simon, Alexander M

    2013-01-15

    Venous valves play a crucial role in blood circulation, promoting the one-way movement of blood from superficial and deep veins towards the heart. By preventing retrograde flow, venous valves spare capillaries and venules from being subjected to damaging elevations in pressure, especially during skeletal muscle contraction. Pathologically, valvular incompetence or absence of valves are common features of venous disorders such as chronic venous insufficiency and varicose veins. The underlying causes of these conditions are not well understood, but congenital venous valve aplasia or agenesis may play a role in some cases. Despite progress in the study of cardiac and lymphatic valve morphogenesis, the molecular mechanisms controlling the development and maintenance of venous valves remain poorly understood. Here, we show that in valved veins of the mouse, three gap junction proteins (Connexins, Cxs), Cx37, Cx43, and Cx47, are expressed exclusively in the valves in a highly polarized fashion, with Cx43 on the upstream side of the valve leaflet and Cx37 on the downstream side. Surprisingly, Cx43 expression is strongly induced in the non-valve venous endothelium in superficial veins following wounding of the overlying skin. Moreover, we show that in Cx37-deficient mice, venous valves are entirely absent. Thus, Cx37, a protein involved in cell-cell communication, is one of only a few proteins identified so far as critical for the development or maintenance of venous valves. Because Cxs are necessary for the development of valves in lymphatic vessels as well, our results support the notion of common molecular pathways controlling valve development in veins and lymphatic vessels.

  10. Computed tomography assessment for transcatheter aortic valve in valve implantation: The vancouver approach to predict anatomical risk for coronary obstruction and other considerations.

    Science.gov (United States)

    Blanke, Philipp; Soon, Jeanette; Dvir, Danny; Park, Jong K; Naoum, Christopher; Kueh, Shaw-Hua; Wood, David A; Norgaard, Bjarne L; Selvakumar, Kapilan; Ye, Jian; Cheung, Anson; Webb, John G; Leipsic, Jonathon

    Valve-in-valve implantation of a transcatheter heart valve into a failed bioprosthetic heart valve has emerged as a treatment alternative to repeat conventional surgery. This requires careful pre-procedural assessment using non-invasive imaging to identify patients at risk for procedure related adverse events, such as ostial coronary occlusion. Herein we report how to comprehensively assess aortic root anatomy using computed tomography prior to transcatheter valve implantation for failed bioprosthetic aortic valves.

  11. Patient-prosthesis mismatch: surgical aortic valve replacement versus transcatheter aortic valve replacement in high risk patients with aortic stenosis.

    Science.gov (United States)

    Ghanta, Ravi K; Kron, Irving L

    2016-10-01

    Patient prosthesis mismatch (PPM) can occur when a prosthetic aortic valve has an effective orifice area (EOA) less than that of a native valve. A recent study by Zorn and colleagues evaluated the incidence and significance of PPM in high risk patients with severe aortic stenosis who were randomized to transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). TAVR is associated with decreased incidence of severe PPM compared to traditional SAVR valves. Severe PPM increases risk for death at 1 year postoperatively in high risk patients. The increased incidence of PPM is largely due to differences in valve design and should encourage development of newer SAVR valves to reduce risk for PPM. In addition more vigorous approaches to root enlargement in small annulus should be performed with SAVR to prevent PPM.

  12. Percutaneous aortic valve replacement using a W-model valved stent: a preliminary feasibility study in sheep

    Institute of Scientific and Technical Information of China (English)

    BAI Yuan; ZONG Gang-jun; WANG Yan-yan; JIANG Hai-bin; LI Wei-ping; WU Hong; ZHAO Xian-xian; QIN Yong-wen

    2009-01-01

    Background Percutaneous aortic valve replacement is a promising strategy in the treatment of patients with aortic valve stenosis. And many kinds of valved stents have been implanted in selected patients worldwide. However, the clinical experience is still limited. We developed a W-model valved stent and evaluated the feasibility and safety of percutaneous implantation of the device in the native aortic valve position.Methods A self expanding nitinol stent with W-model, containing porcine pericardium valves in its proximal part, was implanted in six sheep by means of a 14 French catheter through the right common lilac artery under guidance of fluoroscopy. During stent deployment the original aortic valve was pushed against the aortic wall by the self expanding force of the stent while the new valve was expanded. These sheep were followed up shortly after procedure with supra-aortic angiogram and left ventriculography. Additionally, one sheep was sacrificed after the procedure for anatomic evaluation.Results It was possible to replace the aortic valve in the beating heart in four sheep. The procedure failed in two sheep due to coronary orifice occlusion in one case and severe aortic valve regurgitation in the other case. One sheep was killed one hour after percutaneous aortic valve replacement for anatomic evaluation. There were no signs of damage of the aortic intima, or of obstruction of the coronary orifice.Conclusions Percutaneous aortic valve replacement with a W-model valved stent in the beating heart is possible. Further studies are mandatory to assess safety and efficacy of this kind of valved stent in larger sample size and by longer follow-up period.

  13. Recently patented transcatheter aortic valves in clinical trials.

    Science.gov (United States)

    Neragi-Miandoab, Siyamek; Skripochnik, Edvard; Salemi, Arash; Girardi, Leonard

    2013-12-01

    The most widely used heart valve worldwide is the Edwards Sapien, which currently has 60% of the worldwide transcatheter aortic valve implantation (TAVI) market. The CoreValve is next in line in popularity, encompassing 35% of the worldwide TAVI market. Although these two valves dominate the TAVI market, a number of newer transcatheter valves have been introduced and others are in early clinical evaluation. The new valves are designed to reduce catheter delivery diameter, improve ease of positioning and sealing, and facilitate repositioning or removal. The most recent transcatheter valves for transapical use include Acurate TA (Symetis), Engager (Medtronic), and JenaValve the Portico (St Jude), Sadra Lotus Medical (Boston Scientific), and the Direct Flow Medical. These new inventions may introduce more effective treatment options for high-risk patients with severe aortic stenosis. Improvements in transcatheter valves and the developing variability among them may allow for more tailored approaches with respect to patient's anatomy, while giving operators the opportunity to choose devices they feel more comfortable with. Moreover, introducing new devices to the market will create a competitive environment among producers that will reduce high prices and expand availability. The present review article includes a discussion of recent patents related to Transcatheter Aortic Valves.

  14. Inhibitory role of Notch1 in calcific aortic valve disease.

    Directory of Open Access Journals (Sweden)

    Asha Acharya

    Full Text Available Aortic valve calcification is the most common form of valvular heart disease, but the mechanisms of calcific aortic valve disease (CAVD are unknown. NOTCH1 mutations are associated with aortic valve malformations and adult-onset calcification in families with inherited disease. The Notch signaling pathway is critical for multiple cell differentiation processes, but its role in the development of CAVD is not well understood. The aim of this study was to investigate the molecular changes that occur with inhibition of Notch signaling in the aortic valve. Notch signaling pathway members are expressed in adult aortic valve cusps, and examination of diseased human aortic valves revealed decreased expression of NOTCH1 in areas of calcium deposition. To identify downstream mediators of Notch1, we examined gene expression changes that occur with chemical inhibition of Notch signaling in rat aortic valve interstitial cells (AVICs. We found significant downregulation of Sox9 along with several cartilage-specific genes that were direct targets of the transcription factor, Sox9. Loss of Sox9 expression has been published to be associated with aortic valve calcification. Utilizing an in vitro porcine aortic valve calcification model system, inhibition of Notch activity resulted in accelerated calcification while stimulation of Notch signaling attenuated the calcific process. Finally, the addition of Sox9 was able to prevent the calcification of porcine AVICs that occurs with Notch inhibition. In conclusion, loss of Notch signaling contributes to aortic valve calcification via a Sox9-dependent mechanism.

  15. Transcatheter Aortic Valve Replacement: Comprehensive Review and Present Status

    Science.gov (United States)

    Misenheimer, Jacob A.; Ramaraj, Radhakrishnan

    2017-01-01

    Aortic stenosis is the most common valvular heart disease in the developed world. About 7% of the population over age 65 years suffers from degenerative aortic stenosis. The prognosis of patients with symptomatic severe aortic stenosis is dismal without valve replacement. Even though the American College of Cardiology recommends aortic valve replacement to treat this condition as a class I recommendation, approximately one third of these patients over the age of 75 years are not referred for surgery. Typically, this is from concern about prohibitive surgical risk associated with patient frailty, comorbidities, age, and severe left ventricular dysfunction. The advent in France of transcatheter aortic valve replacement has raised the hope in the United States for an alternative, less invasive treatment for aortic stenosis. Two recent trials—the Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve (Partner) and the CoreValve US Pivotal—have established transcatheter aortic valve replacement as the preferred approach in patients who are at high or prohibitive surgical risk. The more recently published Partner 2 trial has shown the feasibility of transcatheter aortic valve replacement in intermediate-surgical-risk patients as well. With a profile that promises easier use and better valve performance and delivery, newer-generation valves have shown their potential for further improvement in safety profile and overall outcomes. We review the history and status of this topic. PMID:28265210

  16. Cinematics and sticking of heart valves in pulsatile flow test.

    Science.gov (United States)

    Köhler, J; Wirtz, R

    1991-05-01

    The aim of the project was to develop laboratory test devices for studies of the cinematics and sticking behaviour of technical valve protheses. The second step includes testing technical valves of different types and sizes under static and dynamic conditions. A force-deflection balance was developed in order to load valve rims by static radial forces until sticking or loss of a disc (sticking- and clamping-mould point) with computer-controlled force deflection curves. A second deflection device was developed and used for prosthetic valves in the aortic position of a pulsatile mock circulation loop with simultaneous video-cinematography. The stiffness of technical valve rims varied between 0.20 (St. Jude) and about 1.0 N/micron (metal rim valves). The stiffness decreased significantly with increasing valve size. Sticking under pulsatile flow conditions was in good agreement with the static deflection measurements. Hence, valve sticking with increasing danger of thrombus formation is more likely with a less stiff valve rim. In the case of forces acting perpendicularly to the pendulum axis, the clamping mould-point of the valve can be reached, followed by disc dislodgement.

  17. Morphological aspects of atrioventricular valves in the ostrich (Struthio camelus

    Directory of Open Access Journals (Sweden)

    Marco A. Pereira-Sampaio

    2013-11-01

    Full Text Available Heart anatomy in the ostrich has been reported, but there are few information on the histological features of the atrioventricular valves. Hearts of young ostriches were fixed in 10% formaldehyde for 24 h and dissected to characterize their macroscopic anatomy. Samples of valves were harvested and stained with Mallory’s trichrome, Gomori’s trichrome, and Picro-Sirius red, for later analysis. The right atrioventricular valve consists of a muscle flap with two fixations. The left atrioventricular valve consists of two layers of endocardium with a layer of connective tissue between them. The free border of the tricuspid valve supports a varying number of chordae tendineae. One of the cusps is attached to the septum, while the other two cusps are attached to the opposite wall. The aortic valve, as well as the pulmonary trunk valve, consists of three cusps. The right atrioventricular valve showed up only as a muscle flap of myocardium coated with a thin layer of dense connective tissue, with two fixations. In the connective tissue, we find a predominance of type I collagen fibers and a lesser amount of type III, with a small presence of elastic fibers. The presence of Purkinje fibers were also usual in the valvular subendocardium, suggesting that they directly participate in the transmission of nervous stimulation to the muscle fibers within the valves. The left atrioventricular valve consisted of 3 cusps, a dorsal, a left, and a right.

  18. Development of Overflow-Prevention Valve with Trigger Mechanism.

    Science.gov (United States)

    Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya

    2016-09-01

    A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.

  19. Valve replacement in children: a challenge for a whole life.

    Science.gov (United States)

    Henaine, Roland; Roubertie, François; Vergnat, Mathieu; Ninet, Jean

    2012-10-01

    Valvular pathology in infants and children poses numerous challenges to the paediatric cardiac surgeon. Without question, valvular repair is the goal of intervention because restoration of valvular anatomy and physiology using native tissue allows for growth and a potentially better long-term outcome. When reconstruction fails or is not feasible, valve replacement becomes inevitable. Which valve for which position is controversial. Homograft and bioprosthetic valves achieve superior haemodynamic results initially but at the cost of accelerated degeneration. Small patient size and the risk of thromboembolism limit the usefulness of mechanical valves, and somatic outgrowth is an universal problem with all available prostheses. The goal of this article is to address valve replacement options for all four valve positions within the paediatric population. We review current literature and our practice to support our preferences. To summarize, a multitude of opinions and surgical experiences exist. Today, the valve choices that seem without controversy are bioprosthetic replacement of the tricuspid valve and Ross or Ross-Konno procedures when necessary for the aortic valve. On the other hand, bioprostheses may be implanted when annular pulmonary diameter is adequate; if not or in case of right ventricular outflow tract discontinuity, it is better to use a pulmonary homograft with the Ross procedure. Otherwise, a valved conduit. Mitral valve replacement remains the most problematic; the mechanical prosthesis must be placed in the annular position, avoiding oversizing. Future advances with tissue-engineered heart valves for all positions and new anticoagulants may change the landscape for valve replacement in the paediatric population.

  20. Modification and performance evaluation of a mono-valve engine

    Science.gov (United States)

    Behrens, Justin W.

    A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.

  1. Aortic valve replacement in geriatric patients with small aortic roots: are sutureless valves the future? †

    Science.gov (United States)

    Shrestha, Malakh; Maeding, Ilona; Höffler, Klaus; Koigeldiyev, Nurbol; Marsch, Georg; Siemeni, Thierry; Fleissner, Felix; Haverich, Axel

    2013-01-01

    OBJECTIVES Aortic valve replacement (AVR) in geriatric patients (>75 years) with small aortic roots is a challenge. Patient–prosthesis mismatch and the long cross-clamp time necessary for stentless valves or root enlargement are matters of concern. We compared the results of AVR with sutureless valves (Sorin Perceval), against those with conventional biological valves. METHODS Between April 2007 and December 2012, 120 isolated AVRs were performed in patients with a small annulus (<22 mm) at our centre. In 70 patients (68 females, age 77.4 ± 5.5 years), conventional valves (C group) and in 50 patients (47 females, age 79.8 ± 4.5 years), sutureless valves (P group) were implanted. The Logistic EuroSCORE of the C group was 16.7 ± 10.4 and that of the P group 20.4 ± 10.7, (P = 0.054). Minimal-access surgery was performed in 4.3% (3/70) patients in the C group and 72% (36/50) patients in the P group. RESULTS The cardiopulmonary bypass (CPB) and cross-clamp times of the C group were 75.3 ± 23 and 50.3 ± 14.2 min vs 58.7 ± 20.9 and 30.1 ± 9 min in the P group, (P < 0.001). In the C group, two annulus enlargements were performed. Thirty-day mortality was 4.3% (n = 3) in the C group and 0 in the P group, (n.s.). At follow-up (up to 5 years), mortalities were 17.4% (n = 12) in the C group and 14% (n = 7) in the P group, (n.s.). CONCLUSIONS This study highlights the advantages of sutureless valves for geriatric patients with small aortic roots reflected by shorter cross-clamp and CPB times, even though most of these patients were operated on via a minimally invasive access. Moreover, due to the absence of a sewing ring, these valves are also almost stentless, with greater effective orifice area (EOA) for any given size. This may potentially result in better haemodynamics even without the root enlargement. This is of advantage, as several studies have shown that aortic root enlargement can significantly increase the risks of AVR. Moreover, as seen in this series

  2. Method and system for measuring gate valve clearances and seating force

    Science.gov (United States)

    Casada, Donald A.; Haynes, Howard D.; Moyers, John C.; Stewart, Brian K.

    1996-01-01

    Valve clearances and seating force, as well as other valve operational parameters, are determined by measuring valve stem rotation during opening and closing operations of a translatable gate valve. The magnitude of the stem rotation, and the relative difference between the stem rotation on opening and closing provides valuable data on the valve internals in a non-intrusive manner.

  3. 46 CFR 38.10-1 - Valves, fittings, and accessories-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... valves to close in case of fire. The quick-closing shutoff valves shall be capable of local manual... 46 Shipping 1 2010-10-01 2010-10-01 false Valves, fittings, and accessories-TB/ALL. 38.10-1... GASES Piping, Valves, Fittings, and Accessory Equipment § 38.10-1 Valves, fittings, and accessories—TB...

  4. Modeling and Investigation of Electromechanical Valve Train Actuator at simulated Pressure conditions

    DEFF Research Database (Denmark)

    Habib, Tufail

    2012-01-01

    In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about investig...

  5. Method and system for measuring gate valve clearances and seating force

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D.A.; Haynes, H.D.; Moyers, J.C.; Stewart, B.K.

    1996-01-30

    Valve clearances and seating force, as well as other valve operational parameters, are determined by measuring valve stem rotation during opening and closing operations of a translatable gate valve. The magnitude of the stem rotation, and the relative difference between the stem rotation on opening and closing provides valuable data on the valve internals in a non-intrusive manner. 8 figs.

  6. Native Pulmonic Valve Endocarditis due to Mycobacterium fortuitum: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Aaron M. Mulhall

    2015-01-01

    Full Text Available Endocarditis secondary to Mycobacterium fortuitum is a rare entity often involving prosthetic valves and rarely native valves. Pulmonic valve endocarditis secondary to any organism is rare. We report the first case of native pulmonic valve endocarditis secondary to M. fortuitum and a literature review of native valve M. fortuitum endocarditis.

  7. Prosthetic valve endocarditis with valvular obstruction after transcatheter aortic valve replacement.

    Science.gov (United States)

    Pabilona, Christine; Gitler, Bernard; Lederman, Jeffrey A; Miller, Donald; Keltz, Theodore N

    2015-04-01

    Patients with severe aortic stenosis who are at high risk for open-heart surgery might be candidates for transcatheter aortic valve replacement (TAVR). To our knowledge, this is the first report of Streptococcus viridans endocarditis that caused prosthetic valve obstruction after TAVR. A 77-year-old man who had undergone TAVR 17 months earlier was admitted because of evidence of prosthetic valve endocarditis. A transthoracic echocardiogram revealed a substantial increase in the transvalvular peak gradient and mean gradient in comparison with an echocardiogram of 7 months earlier. A transesophageal echocardiogram showed a 1.5-cm vegetation obstructing the valve. Blood cultures yielded penicillin-sensitive S. viridans. The patient was hemodynamically stable and was initially treated with vancomycin because of his previous penicillin allergy. Subsequent therapy with levofloxacin, oral penicillin (after a negative penicillin skin test), and intravenous penicillin eliminated the symptoms of the infection. Transcatheter aortic valve replacement is a relatively new procedure, and sequelae are still being discovered. We recommend that physicians consider obstructive endocarditis as one of these.

  8. Wear aspects of internal combustion engine valves

    Science.gov (United States)

    Panţuru, M.; Chicet, D.; Paulin, C.; Alexandru, A.; Munteanu, C.

    2016-08-01

    Because the surface engineering is becoming an increasingly viable alternative to the constructive changes made to improve the efficiency of internal combustion engines, have been proposed and tested various types of coatings of some organs of internal combustion engines. One vital organ is the engine valves, which is subjected during operation to combined thermal, mechanical, corrosion and wear solicitations, which are leading to severe corrosion and complete breakdown. In this paper were analyzed aspects of valves wear and the active surfaces were coated using the atmospheric plasma spraying method (APS) with two commercial powders: Ni-Al and YSZ. Microstructural analyzes were made on these layers and also observations regarding the possibility of using them as thermal barrier and anti-oxidant coatings.

  9. Curved butterfly bileaflet prosthetic cardiac valve

    Science.gov (United States)

    McQueen, David M.; Peskin, Charles S.

    1991-06-25

    An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

  10. Bireactor Electronuclear Systems with Liquid Cadmium Valve

    CERN Document Server

    Bznuni, S A; Zhamkochyan, V M; ASosnin, A N; Polanski, A; Khudaverdyan, A H

    2002-01-01

    Three main types of bireactor electronuclear systems are discussed. From the point of view of assuring high level of functional characteristics and safety bireactor electronuclear systems with booster using enriched uranium (20 %) and with a liquid cadmium valve appears to be the most effective. It is shown by means of Monte-Carlo modeling that such operation conditions can be achieved which lead to the destruction of the intermediate cadmium layer making the systems supercritical (k_{eff}>1). One can avoid the problem by using a special design of the liquid cadmium valve. In comparison with other nuclear systems (critical reactors, one-reactor electronuclear systems) cascade electronuclear systems have essential advantages allowing the decrease of the proton beam current by one order of magnitude and providing at same time the necessary level of power generation and neutron flux. Availability of both the thermal and fast cones allows one to transmute not only transuranics but also the fission products - cesi...

  11. Valve-aided twisted Savonius rotor

    Energy Technology Data Exchange (ETDEWEB)

    Jaya Rajkumar, M.; Saha, U.K.

    2006-05-15

    Accessories, such as end plates, deflecting plates, shielding and guide vanes, may increase the power of a Savonius rotor, but make the system structurally complex. In such cases, the rotor can develop a relatively large torque at small rotational speeds and is cheap to build, however it harnesses only a small fraction of the incident wind energy. Another proposition for increasing specific output is to place non-return valves inside the concave side of the blades. Such methods have been studied experimentally with a twisted-blade Thus improving a Savonius rotor's energy capture. This new concept has been named as the 'Valve-Aided Twisted Savonius'rotor. Tests were conducted in a low-speed wind tunnel to evaluate performance. This mechanism is found to be independent of flow direction, and shows potential for large machines. [Author].

  12. Water system microbial check valve development

    Science.gov (United States)

    Colombo, G. V.; Greenley, D. R.; Putnam, D. F.

    1978-01-01

    A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

  13. Valve Technology Arrangement of Cryopump: A Review

    OpenAIRE

    Sanjiv Y. Rajput

    2014-01-01

    A cryopump or a "cryogenic pump" is a vacuum pump that pumps the trap gases and vapours by condensing them on a cold surface. Helium gas which is very light can only be pumped by Cryopump. Cryopump cannot be used when working for continuous operation as it pumps the effluent till the saturation state is achieved. Then the absorbed gases are to be collected through other mechanical pump through regeneration process. Hence, valve technology arrangement is incorporated with the c...

  14. Porcine mitral valve interstitial cells in culture.

    Science.gov (United States)

    Lester, W; Rosenthal, A; Granton, B; Gotlieb, A I

    1988-11-01

    There are connective tissue cells present within the interstitium of the heart valves. This study was designed to isolate and characterize mitral valve interstitial cells from the anterior leaflet of the mitral valve. Explants obtained from the distal part of the leaflet, having been scraped free of surface endocardial cells, were incubated in medium 199 supplemented with 10% fetal bovine serum. Cells grew out of the explant after 3 to 5 days and by 3 weeks these cells were harvested and passaged. Passages 1 to 22 were characterized in several explant sets. The cells showed a growth pattern reminiscent of fibroblasts. Growth was dependent on serum concentration. Cytoskeletal localization of actin and myosin showed prominent stress fibers. Ultrastructural studies showed many elongated cells with prominent stress fibers and some gap junctions and few adherens junctions. There were as well cells with fewer stress fibers containing prominent Golgi complex and dilated endoplasmic reticulum. In the multilayered superconfluent cultures, the former cells tended to be on the substratum of the dish or surface of the multilayered culture, whereas the latter was generally located within the layer of cells. Extracellular matrix was prominent in superconfluent cultures, often within the layers as well. Labeling of the cells with antibody HHF 35 (Tsukada T, Tippens D, Gordon D, Ross R, Gown AM: Am J Pathol 126:51, 1987), which recognizes smooth muscle cell actin, showed prominent staining of the elongated stress fiber-containing cells and much less in the secretory type cells. These studies show that interstitial mitral valve cells can be grown in culture and that either two different cell types or one cell type with two phenotypic expressions is present in culture.

  15. Towards Performance Prognostics of a Launch Valve

    Science.gov (United States)

    2014-10-02

    estimations for the next step. In particular, this work implements a simplified version of the Risk-Sensitive Particle Filter (RSPF) presented by Orchard ...et. al. ( Orchard , 2010). The RSPF maintains a subset of particles in the high- risk, low-likelihood realm to maintain coverage in these areas when...This is a step towards allowing the Launch Valve performance analysis to be handled automatically in real-time onboard ship and provide timely

  16. VALVE: Volcano Analysis and Visualization Environment

    Science.gov (United States)

    Cervelli, D. P.; Cervelli, P.; Miklius, A.; Krug, R.; Lisowski, M.

    2002-12-01

    Modern volcano observatories collect data using a wide variety of instruments. Visualizing these disparate data on a common time base is critical to interpreting and reacting to geophysical changes. With this in mind, the Hawaiian Volcano Observatory (HVO) created Valve, the Volcano Analysis and Visualization Environment. Valve integrates a wide range of both continuous and discontinuous data sources into a common, internet web-browser based interface that allows scientists to interactively select and visualize these data on a common time base and, if appropriate, in three dimensions. Advances in modern internet browser technology allow for a truly interactive user-interface experience that could previously only be found in stand-alone applications--all while maintaining client platform independence and network portability. This system aids more traditional in-depth analysis by providing a common front-end to retrieving raw data. In most cases, the raw data are being served from an SQL database, a system that lends itself to quickly retrieving, logically arranging, and safely storing data. Beyond Valve's visualization capabilities, the system also provides a variety of tools for time series analysis and source modeling. For example, a user could load several tilt and GPS time series, estimate co-seismic or co-intrusive deformation, and then model the event with an elastic point source or dislocation. From the source model, Coulomb stress changes could be calculated and compared to pre- and post-event hypocenter distribution. Employing a heavily object-oriented design, Valve is easily extensible, modular, portable, and remarkably cost efficient. Quickly visualizing arbitrary data is a trivial matter, while implementing methods for permanent, continuous data streams requires only minimal programming. Portability is ensured by using software that is readily available on a wide variety of operating systems; cost efficiency is achieved by using software that is open

  17. Apyrexic Brucella melitensis aortic valve endocarditis.

    Science.gov (United States)

    al-Mudallal, D S; Mousa, A R; Marafie, A A

    1989-10-01

    The case of a young shepherd with Brucella melitensis aortic valve endocarditis is presented. His illness ran an afebrile course and was also complicated by disseminated intravascular coagulation (DIC), nephritis, hepatitis and peritonitis, all of which responded well to supportive measures and a combination of tetracycline, trimethoprim-sulphamethoxazole and amikacin sulphate. The fact that even the most severe case of brucellosis can present without fever is stressed.

  18. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2012-01-31

    AIM: The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range. METHODS: Five Neopuffs were set up to provide a PEEP of 5 cm H(2) O. The number of clockwise revolutions to complete occlusion of the PEEP valve and the mean and range of pressures at each quarter clockwise revolution were recorded at gas flow rates between 5 and 15 L\\/min. Results: At 5, 10 and 15 L\\/min, 0.5, 1.7 and 3.4 full clockwise rotations were required to completely occlude the PEEP valve, and pressures rose from 5 to 11.4, 18.4 and 21.5 cm H(2) O, respectively. At a flow rate of 5 L\\/min, half a rotation of the PEEP dial resulted in a rise in PEEP from 5 to 11.4cm H(2) O. At 10 L\\/min, half a rotation resulted in a rise from 5 to 7.7cm H(2) O, and at 15 L\\/min PEEP rose from 5 to 6.8cm H(2) O. CONCLUSION: Users of the Neopuff should be aware that the PEEP valve is more sensitive at lower flow rates and that half a rotation of the dial at 5 L\\/min gas flow can more than double the PEEP.

  19. Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: Clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA

    NARCIS (Netherlands)

    J. Baan; Z.Y. Yong; K.T. Koch; J.P.S. Henriques; B.J. Bouma; S.G. de Hert; J. van der Meulen; J.G.P. Tijssen; J.J. Piek; B.A.J.M. de Mol

    2010-01-01

    Objective. To report the feasibility, safety and efficacy of percutaneous aortic valve implantation (PAVI) with the CoreValve self-expanding aortic valve bioprosthesis in elderly patients with aortic valve stenosis who are rejected for surgery or have a high surgical risk.Methods. PAVI using the Cor

  20. Effects of valve geometry and tissue anisotropy on the radial stretch and coaptation area of tissue-engineered heart valves.

    Science.gov (United States)

    Loerakker, S; Argento, G; Oomens, C W J; Baaijens, F P T

    2013-07-26

    Tissue engineering represents a promising technique to overcome the limitations of the current valve replacements, since it allows for creating living autologous heart valves that have the potential to grow and remodel. However, also this approach still faces a number of challenges. One particular problem is regurgitation, caused by cell-mediated tissue retraction or the mismatch in geometrical and material properties between tissue-engineered heart valves (TEHVs) and their native counterparts. The goal of the present study was to assess the influence of valve geometry and tissue anisotropy on the deformation profile and closed configuration of TEHVs. To achieve this aim, a range of finite element models incorporating different valve shapes was developed, and the constitutive behavior of the tissue was modeled using an established computational framework, where the degree of anisotropy was varied between values representative of TEHVs and native valves. The results of this study suggest that valve geometry and tissue anisotropy are both important to maximize the radial strains and thereby the coaptation area. Additionally, the minimum degree of anisotropy that is required to obtain positive radial strains was shown to depend on the valve shape and the pressure to which the valves are exposed. Exposure to pulmonary diastolic pressure only yielded positive radial strains if the anisotropy was comparable to the native situation, whereas considerably less anisotropy was required if the valves were exposed to aortic diastolic pressure.