WorldWideScience

Sample records for longitudinal magnetic resonance

  1. Measurements of the longitudinal nuclear magnetic resonance in superfluid helium-3 B as a function of magnetic field

    International Nuclear Information System (INIS)

    Sherrill, D.S.

    1987-01-01

    These are the first measurements of the longitudinal NMR mode in a magnetic field large enough to cause an appreciable distortion of the energy gap. Measurements were made at pressures P = 3, 6, 12, 21, and 33 bar; at fields from 2 to 15 MHz; and over temperatures between 0.18 and 0.40 T/sub c/(P), where T/sub c/(P) is the superfluid transition temperature. Therefore, these experiments are in the collisionless regime in which the longitudinal resonance frequency is small compared to the quasiparticle collision frequency. The gap distortion causes a large shift in the longitudinal frequency. As the magnetic field increases from 2 to 15 MHz, the frequency decreases by about 20 kHz at all pressures. Thus, these experiments are a powerful probe of the field distortion of the energy gap. Pulsed NMR is used and, in addition to the resonance frequency, the amplitude and damping of the induced oscillations were obtained. Results are compared for the longitudinal frequency as a function of field, temperature, and pressure to a recent theory, and estimates of the theoretical parameters involved were obtained. At the lowest temperatures a startling behavior was observed, in which the resonance lineshape broadened with decreasing temperature

  2. Gradient-induced longitudinal relaxation of hyperpolarized noble gases in the fringe fields of superconducting magnets used for magnetic resonance.

    Science.gov (United States)

    Zheng, Wangzhi; Cleveland, Zackary I; Möller, Harald E; Driehuys, Bastiaan

    2011-02-01

    When hyperpolarized noble gases are brought into the bore of a superconducting magnet for magnetic resonance imaging (MRI) or spectroscopy studies, the gases must pass through substantial field gradients, which can cause rapid longitudinal relaxation. In this communication, we present a means of calculating this spatially dependent relaxation rate in the fringe field of typical magnets. We then compare these predictions to experimental measurements of (3)He relaxation at various positions near a medium-bore 2-T small animal MRI system. The calculated and measured relaxation rates on the central axis of the magnet agree well and show a maximum (3)He relaxation rate of 3.83×10(-3) s(-1) (T(1)=4.4 min) at a distance of 47 cm from the magnet isocenter. We also show that if this magnet were self-shielded, its minimum T(1) would drop to 1.2 min. In contrast, a typical self-shielded 1.5-T clinical MRI scanner will induce a minimum on-axis T(1) of 12 min. Additionally, we show that the cylindrically symmetric fields of these magnets enable gradient-induced relaxation to be calculated using only knowledge of the on-axis longitudinal field, which can either be measured directly or calculated from a simple field model. Thus, while most MRI magnets employ complex and proprietary current configurations, we show that their fringe fields and the resulting gradient-induced relaxation are well approximated by simple solenoid models. Finally, our modeling also demonstrates that relaxation rates can increase by nearly an order of magnitude at radial distances equivalent to the solenoid radius. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. High-Resolution Longitudinal Screening with Magnetic Resonance Imaging in a Murine Brain Cancer Model

    Directory of Open Access Journals (Sweden)

    Nicholas A. Bock

    2003-11-01

    Full Text Available One of the main limitations of intracranial models of diseases is our present inability to monitor and evaluate the intracranial compartment noninvasively over time. Therefore, there is a growing need for imaging modalities that provide thorough neuropathological evaluations of xenograft and transgenic models of intracranial pathology. In this study, we have established protocols for multiple-mouse magnetic resonance imaging (MRI to follow the growth and behavior of intracranial xenografts of gliomas longitudinally. We successfully obtained weekly images on 16 mice for a total of 5 weeks on a 7-T multiple-mouse MRI. T2- and Ti-weighted imaging with gadolinium enhancement of vascularity was used to detect tumor margins, tumor size, and growth. These experiments, using 3D whole brain images obtained in four mice at once, demonstrate the feasibility of obtaining repeat radiological images in intracranial tumor models and suggest that MRI should be incorporated as a research modality for the investigation of intracranial pathobiology.

  4. Magnetic Resonance Imaging of Stroke

    NARCIS (Netherlands)

    Bouts, Mark. J. R. J.; Wu, O.; Dijkhuizen, R. M.

    2017-01-01

    Magnetic resonance imaging (MRI) provides a powerful (neuro)imaging modality for the diagnosis and outcome prediction after (acute) stroke. Since MRI allows noninvasive, longitudinal, and three-dimensional assessment of vessel occlusion (with magnetic resonance angiography (MRA)), tissue injury

  5. Longitudinal stress fractures of the tibia: diagnosis by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Umans, H.R.; Kaye, J.J.

    1996-01-01

    Previous works describe magnetic resonance (MR) imaging characteristics of stress fractures. This report focusses on MR imaging of longitudinal stress fractures of the tibia. Six cases are presented in which a longitudinal linear abnormal marrow signal was detected in the middle and distal parts of the tibial shaft. Five patients were imaged using a 1.5 Tesla MR unit. Axial, sagittal and coronal T1 and T2-weighted or fat suppressed proton density fast spin echo images were obtained in all but one patient. One patient was imaged using a 0.5 Tesla MR unit with axial and coronal T1- and T2-weighted sequences. Initial conventional radiographs seen at clinical presentation were interpreted as normal in all cases. Two patients underwent radionuclide bone scan, and one patient was imaged with CT prior to MR imaging. In each instance, MR imaging demonstrated linear marrow signal abnormalities orientated along the long axis of the tibial shaft. Endosteal and periosteal callus was identified on axial images. In all cases, MR imaging clearly demonstrated a fracture extending through one cortex with abnormal signal in both the marrow cavity as well as adjacent soft tissues indicating edema. (orig./MG)

  6. Longitudinal stress fractures of the tibia: diagnosis by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Umans, H.R. [Dept. of Radiology, Albert Einstein Coll. of Medicine and Montefiore Medical Center, Bronx, NY (United States); Kaye, J.J. [The Hospital for Special Surgery, New York, NY (United States)

    1996-05-01

    Previous works describe magnetic resonance (MR) imaging characteristics of stress fractures. This report focusses on MR imaging of longitudinal stress fractures of the tibia. Six cases are presented in which a longitudinal linear abnormal marrow signal was detected in the middle and distal parts of the tibial shaft. Five patients were imaged using a 1.5 Tesla MR unit. Axial, sagittal and coronal T1 and T2-weighted or fat suppressed proton density fast spin echo images were obtained in all but one patient. One patient was imaged using a 0.5 Tesla MR unit with axial and coronal T1- and T2-weighted sequences. Initial conventional radiographs seen at clinical presentation were interpreted as normal in all cases. Two patients underwent radionuclide bone scan, and one patient was imaged with CT prior to MR imaging. In each instance, MR imaging demonstrated linear marrow signal abnormalities orientated along the long axis of the tibial shaft. Endosteal and periosteal callus was identified on axial images. In all cases, MR imaging clearly demonstrated a fracture extending through one cortex with abnormal signal in both the marrow cavity as well as adjacent soft tissues indicating edema. (orig./MG)

  7. Reliability measures of functional magnetic resonance imaging in a longitudinal evaluation of mild cognitive impairment.

    Science.gov (United States)

    Zanto, Theodore P; Pa, Judy; Gazzaley, Adam

    2014-01-01

    As the aging population grows, it has become increasingly important to carefully characterize amnestic mild cognitive impairment (aMCI), a preclinical stage of Alzheimer's disease (AD). Functional magnetic resonance imaging (fMRI) is a valuable tool for monitoring disease progression in selectively vulnerable brain regions associated with AD neuropathology. However, the reliability of fMRI data in longitudinal studies of older adults with aMCI is largely unexplored. To address this, aMCI participants completed two visual working tasks, a Delayed-Recognition task and a One-Back task, on three separate scanning sessions over a three-month period. Test-retest reliability of the fMRI blood oxygen level dependent (BOLD) activity was assessed using an intraclass correlation (ICC) analysis approach. Results indicated that brain regions engaged during the task displayed greater reliability across sessions compared to regions that were not utilized by the task. During task-engagement, differential reliability scores were observed across the brain such that the frontal lobe, medial temporal lobe, and subcortical structures exhibited fair to moderate reliability (ICC=0.3-0.6), while temporal, parietal, and occipital regions exhibited moderate to good reliability (ICC=0.4-0.7). Additionally, reliability across brain regions was more stable when three fMRI sessions were used in the ICC calculation relative to two fMRI sessions. In conclusion, the fMRI BOLD signal is reliable across scanning sessions in this population and thus a useful tool for tracking longitudinal change in observational and interventional studies in aMCI. © 2013.

  8. Differentiating neuromyelitis optica from other causes of longitudinally extensive transverse myelitis on spinal magnetic resonance imaging

    Science.gov (United States)

    Pekcevik, Yeliz; Mitchell, Charles H; Mealy, Maureen A; Orman, Gunes; Lee, In H; Newsome, Scott D; Thompson, Carol B; Pardo, Carlos A; Calabresi, Peter A; Levy, Michael; Izbudak, Izlem

    2016-01-01

    Background Although spinal magnetic resonance imaging (MRI) findings of neuromyelitis optica (NMO) have been described, there is limited data available that help differentiate NMO from other causes of longitudinally extensive transverse myelitis (LETM). Objective To investigate the spinal MRI findings of LETM that help differentiate NMO at the acute stage from multiple sclerosis (MS) and other causes of LETM. Methods We enrolled 94 patients with LETM into our study. Bright spotty lesions (BSL), the lesion distribution and location were evaluated on axial T2-weighted images. Brainstem extension, cord expansion, T1 darkness and lesion enhancement were noted. We also reviewed the brain MRI of the patients during LETM. Results Patients with NMO had a greater amount of BSL and T1 dark lesions (p < 0.001 and 0.003, respectively). The lesions in NMO patients were more likely to involve greater than one-half of the spinal cord’s cross-sectional area; to enhance and be centrally-located, or both centrally- and peripherally-located in the cord. Of the 62 available brain MRIs, 14 of the 27 whom were NMO patients had findings that may be specific to NMO. Conclusions Certain spinal cord MRI features are more commonly seen in NMO patients and so obtaining brain MRI during LETM may support diagnosis. PMID:26209588

  9. The longitudinal reliability and responsiveness of the OMERACT Hand Osteoarthritis Magnetic Resonance Imaging Scoring System (HOAMRIS)

    DEFF Research Database (Denmark)

    Haugen, Ida K.; Eshed, Iris; Gandjbakhch, Frederique

    2015-01-01

    Objective. To evaluate the interreader reliability of change scores and the responsiveness of the OMERACT Hand Osteoarthritis (OA) Magnetic Resonance Image (MRI) Scoring System (HOAMRIS). Methods. Paired MRI (baseline and 5-yr followup) from 20 patients with hand OA were scored with known time se...

  10. Longitudinal and transverse right ventricular function in pulmonary hypertension: cardiovascular magnetic resonance imaging study from the ASPIRE registry.

    Science.gov (United States)

    Swift, Andrew J; Rajaram, Smitha; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G

    2015-09-01

    Right ventricular (RV) function is a strong predictor of outcome in cardiovascular diseases. Two components of RV function, longitudinal and transverse motion, have been investigated in pulmonary hypertension (PH). However, their individual clinical significance remains uncertain. The aim of this study was to determine the factors associated with transverse and longitudinal RV motion in patients with PH. In 149 treatment-naive patients with PH and 16 patients with suspected PH found to have mean pulmonary arterial pressure of transverse motion (fractional septum to free wall distance [f-SFD]; P = 0.002). In patients without PH, no significant difference between f-SFD and f-TAAD was identified (P = 0.442). Longitudinal RV motion was singularly associated with RV ejection fraction independent of age, invasive hemodynamics, and cardiac magnetic resonance measurements (P = 0.024). In contrast, transverse RV motion was independently associated with left ventricular eccentricity (P = 0.036) in addition to RV ejection fraction (P = 0.014). In conclusion, RV motion is significantly greater in the longitudinal direction in patients with PH, whereas patients without PH have equal contributions of transverse and longitudinal motion. Longitudinal RV motion is primarily associated with global RV pump function in PH. Transverse RV motion not only reflects global pump function but is independently influenced by ventricular interaction in patients with PH.

  11. Magnetic resonance annual 1986

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1986-01-01

    This book contains papers written on magnetic resonance during 1986. Topics include: musculosketetal magnetic resonance imaging; imaging of the spine; magnetic resonance chemical shift imaging; magnetic resonance imaging in the central nervous system; comparison to computed tomography; high resolution magnetic resonance imaging using surface coils; magnetic resonance imaging of the chest; magnetic resonance imaging of the breast; magnetic resonance imaging of the liver; magnetic resonance spectroscopy of neoplasms; blood flow effects in magnetic resonance imaging; and current and potential applications of clinical sodium magnetic resonance imaging

  12. Validation of the OMERACT Magnetic Resonance Imaging Joint Space Narrowing Score for the Wrist in a Multireader Longitudinal Trial

    DEFF Research Database (Denmark)

    Glinatsi, Daniel; Lillegraven, Siri; Haavardsholm, Espen A

    2015-01-01

    OBJECTIVE: To assess the intrareader and interreader agreement and sensitivity to change of the Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Joint Space Narrowing (RAMRIS-JSN) score in the rheumatoid arthritis (RA) wrist in a longitudinal multireader...... exercise. METHODS: Coronal T1-weighted MR image sets of 1 wrist from 20 patients with early RA were assessed twice for JSN at 17 sites at baseline and after 36 or 60 months by 4 readers blinded to patient data but not time order. The joints were scored 0-4 according to the OMERACT RAMRIS-JSN score...

  13. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  14. Veins in plaques of multiple sclerosis patients - a longitudinal magnetic resonance imaging study at 7 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Dal-Bianco, Assunta; Auff, Eduard; Leutmezer, Fritz; Vass, Karl [Medical University of Vienna, Department of Neurology, Wien (Austria); Hametner, Simon [Medical University of Vienna, Center for Brain Research, Wien (Austria); Grabner, Guenther; Schernthaner, Melanie; Kronnerwetter, Claudia; Trattnig, Siegfried [Medical University of Vienna, Department of Radiology, Wien (Austria); Reitner, Andreas; Vass, Clemens; Kircher, Karl [Medical University of Vienna, Department of Ophthalmology, Wien (Austria)

    2015-10-15

    To monitor the venous volumes in plaques of patients with multiple sclerosis (MS) compared to an age-matched control group over a period of 3.5 years. Ten MS patients underwent an annual neurological examination and MRI. Susceptibility-weighted imaging (SWI) combined with fluid-attenuated inversion recovery (FLAIR) or FLAIR-like contrast at 7 Tesla (7 T) magnetic resonance imaging (MRI) was used for manual segmentation of veins in plaques, in the normal-appearing white matter (NAWM) and in location-matched white matter of 9 age-matched controls. Venous volume to tissue volume ratio was assessed for each time point in order to describe the dynamics of venous volumes in MS plaques over time. MS plaques, which were newly detected during the study period, showed significantly higher venous volumes compared to the preplaque area 1 year before plaque detection and the corresponding NAWM regions. Venous volumes in established MS plaques, which were present already in the first scans, were significantly higher compared to the NAWM and controls. Our data underpin a relation of veins and plaque development in MS and reflect increased apparent venous calibers due to increased venous diameters or increased oxygen consumption in early MS plaques. (orig.)

  15. Veins in plaques of multiple sclerosis patients - a longitudinal magnetic resonance imaging study at 7 Tesla

    International Nuclear Information System (INIS)

    Dal-Bianco, Assunta; Auff, Eduard; Leutmezer, Fritz; Vass, Karl; Hametner, Simon; Grabner, Guenther; Schernthaner, Melanie; Kronnerwetter, Claudia; Trattnig, Siegfried; Reitner, Andreas; Vass, Clemens; Kircher, Karl

    2015-01-01

    To monitor the venous volumes in plaques of patients with multiple sclerosis (MS) compared to an age-matched control group over a period of 3.5 years. Ten MS patients underwent an annual neurological examination and MRI. Susceptibility-weighted imaging (SWI) combined with fluid-attenuated inversion recovery (FLAIR) or FLAIR-like contrast at 7 Tesla (7 T) magnetic resonance imaging (MRI) was used for manual segmentation of veins in plaques, in the normal-appearing white matter (NAWM) and in location-matched white matter of 9 age-matched controls. Venous volume to tissue volume ratio was assessed for each time point in order to describe the dynamics of venous volumes in MS plaques over time. MS plaques, which were newly detected during the study period, showed significantly higher venous volumes compared to the preplaque area 1 year before plaque detection and the corresponding NAWM regions. Venous volumes in established MS plaques, which were present already in the first scans, were significantly higher compared to the NAWM and controls. Our data underpin a relation of veins and plaque development in MS and reflect increased apparent venous calibers due to increased venous diameters or increased oxygen consumption in early MS plaques. (orig.)

  16. One-Dimensional-Ratio Measures of Atrophy Progression in Multiple Sclerosis as Evaluated by Longitudinal Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Martola, J.; Wiberg Kristoffersen, M.; Aspelin, P.; Stawiarz, L.; Fredrikson, S.; Hillert, J.; Bergstroem, J.; Flodmark, O.

    2009-01-01

    Background: For decades, normalized one-dimensional (1D) measures have been used in the evaluation of brain atrophy. In multiple sclerosis (MS), the use of normalized linear measures over longitudinal follow-up remains insufficiently documented. Purpose: To evaluate the association between different regional atrophy measures and disability in MS patients over four decades in a longitudinal cross-sectional study. Material and Methods: 37 consecutively selected MS patients were included. At baseline, patients had a range of disease duration (1-33 years) and age (24-65 years). Each patient was followed by magnetic resonance imaging (MRI) for a mean of 9.25 years (range 7.3-10 years). Four 1D measures were applied at three time points on axial 5-mm T1-weighted images. Three clinical MS subgroups were represented: relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), and primary progressive MS (PPMS). Results: There were significant changes in all 1D ratios during follow-up. The Evans ratio (ER) and the bifrontal ratio (BFR) were associated with the development of disability. Changes of ER and BFR reflected more aggressive disease progression, as expressed by MS severity score (MSSS). Conclusion: All four normalized ratios showed uniform atrophy progression, suggesting a consistent rate of atrophy over long-term disease duration independent of MS course. Disability status correlated with 1D measures, suggesting that serial evaluation of Evans and bifrontal ratios might contribute to the radiological evaluation of MS patients

  17. Longitudinal magnetic resonance imaging study on whiplash injury patients. Minimum 10-year follow-up

    International Nuclear Information System (INIS)

    Ichihara, Daisuke; Okada, Eijiro; Chiba, Kazuhiro

    2009-01-01

    We conducted a prospective long-term follow-up study to assess associations between magnetic resonance imaging (MRI) findings and changes in clinical symptoms, as well as factors relating to the prognosis of symptoms. A total of 133 patients with acute whiplash injury between 1993 and 1996 participated in this follow-up study. They underwent neurological examinations by spine surgeons and second MRI scans of the cervical spine were obtained. They also filled out a questionnaire regarding cervical symptoms and the accident details. The items evaluated by MRI were a decrease in the signal intensity of the intervertebral disc; anterior compression of the dura and the spinal cord; posterior disc protrusion; disc space narrowing; and foraminal stenosis. Relations between the presence/absence of degenerative changes on MRI, accident details, and patients' symptoms were assessed by calculating the adjusted odds ratio (OR). Progression of some degenerative changes was recognized on MRI in 98.5% of the 133 whiplash injury patients, and clinical symptoms diminished in more than a half of the 133 patients. There were no statistically significant associations between MRI findings and changes in clinical symptoms. The prognosis for neck pain tended to be poor after accidents with double collisions (rear-end collision followed by front-end collision) [adjusted OR 5.83, 95% confidence interval (CI) 1.15-29.71] and accidents with serious car damage (2.87, 1.03-7.99). The prognosis for stiff shoulders tended to be poor in women (2.83, 1.23-6.51); and the prognosis for numbness in the upper extremities tended to be poor after accidents with serious car damage (3.39, 1.14-10.06). This study demonstrated that progression of degenerative changes of the cervical spine on MRI was not associated with clinical symptoms during the 10-year period after whiplash injury. (author)

  18. Longitudinal in vivo magnetic resonance imaging studies in experimental allergic encephalomyelitis : effect of a neurotrophic treatment on cortical lesion development

    NARCIS (Netherlands)

    Duckers, H.J.; Muller, H J; Verhaagen, J; Nicolay, K; Gispen, Willem Hendrik

    Proton magnetic resonance imaging enables non-invasive monitoring of lesion formation in multiple sclerosis and has an important role in assessing the potential effects of therapy. T2-weighted and short tau inversion recovery magnetic resonance imaging were used to assess the effect of a

  19. Radiation Dose–Dependent Hippocampal Atrophy Detected With Longitudinal Volumetric Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seibert, Tyler M.; Karunamuni, Roshan [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Bartsch, Hauke [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Kaifi, Samar [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Krishnan, Anitha Priya [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Dalia, Yoseph; Burkeen, Jeffrey; Murzin, Vyacheslav; Moiseenko, Vitali [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States); Kuperman, Joshua; White, Nathan S. [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Brewer, James B. [Department of Radiology, University of California, San Diego, La Jolla, California (United States); Department of Neurosciences, University of California, San Diego, La Jolla, California (United States); Farid, Nikdokht [Department of Radiology, University of California, San Diego, La Jolla, California (United States); McDonald, Carrie R. [Department of Psychiatry, University of California, San Diego, La Jolla, California (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, California (United States)

    2017-02-01

    Purpose: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. Methods and Materials: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI before and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. Results: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=−0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean −6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). Conclusions: The hippocampus demonstrates radiation dose–dependent atrophy after treatment for brain

  20. Improved longitudinal length accuracy of gross tumor volume delineation with diffusion weighted magnetic resonance imaging for esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Hou, Dong-Liang; Shi, Gao-Feng; Gao, Xian-Shu; Asaumi, Junichi; Li, Xue-Ying; Liu, Hui; Yao, Chen; Chang, Joe Y

    2013-01-01

    To analyze the longitudinal length accuracy of gross tumor volume (GTV) delineation with diffusion weighted magnetic resonance imaging for esophageal squamous cell carcinoma (SCC). Forty-two patients from December 2011 to June 2012 with esophageal SCC who underwent radical surgery were analyzed. Routine computed tomography (CT) scan, T2-weighted MRI and diffusion weighted magnetic resonance imaging (DWI) were employed before surgery. Diffusion-sensitive gradient b-values were taken at 400, 600, and 800 s/mm 2 . Gross tumor volumes (GTV) were delineated using CT, T2-weighted MRI and DWI on different b-value images. GTV longitude length measured using the imaging modalities listed above was compared with pathologic lesion length to determine the most accurate imaging modality. CMS Xio radiotherapy planning system was used to fuse DWI scans and CT images to investigate the possibility of delineating GTV on fused images. The differences between the GTV length according to CT, T2-weighted MRI and pathology were 3.63 ± 12.06 mm and 3.46 ± 11.41 mm, respectively. When the diffusion-sensitive gradient b-value was 400, 600, and 800 s/mm 2 , the differences between the GTV length using DWI and pathology were 0.73 ± 6.09 mm, -0.54 ± 6.03 mm and −1.58 ± 5.71 mm, respectively. DWI scans and CT images were fused accurately using the radiotherapy planning system. GTV margins were depicted clearly on fused images. DWI displays esophageal SCC lengths most precisely when compared with CT or regular MRI. DWI scans fused with CT images can be used to improve accuracy to delineate GTV in esophageal SCC

  1. Longitudinal diffusion tensor magnetic resonance imaging study of radiation-induced white matter damage in a rat model.

    Science.gov (United States)

    Wang, Silun; Wu, Ed X; Qiu, Deqiang; Leung, Lucullus H T; Lau, Ho-Fai; Khong, Pek-Lan

    2009-02-01

    Radiation-induced white matter (WM) damage is a major side effect of whole brain irradiation among childhood cancer survivors. We evaluate longitudinally the diffusion characteristics of the late radiation-induced WM damage in a rat model after 25 and 30 Gy irradiation to the hemibrain at 8 time points from 2 to 48 weeks postradiation. We hypothesize that diffusion tensor magnetic resonance imaging (DTI) indices including fractional anisotropy (FA), trace, axial diffusivity (lambda(//)), and radial diffusivity (lambda( perpendicular)) can accurately detect and monitor the histopathologic changes of radiation-induced WM damage, measured at the EC, and that these changes are dose and time dependent. Results showed a progressive reduction of FA, which was driven by reduction in lambda(//) from 4 to 40 weeks postradiation, and an increase in lambda( perpendicular) with return to baseline in lambda(//) at 48 weeks postradiation. Histologic evaluation of irradiated WM showed reactive astrogliosis from 4 weeks postradiation with reversal at 36 weeks, and demyelination, axonal degeneration, and necrosis at 48 weeks postradiation. Moreover, changes in lambda(//) correlated with reactive astrogliosis (P histopathologic changes of WM damage and our results support the use of DTI as a biomarker to noninvasively monitor radiation-induced WM damage.

  2. Atrophy and Primary Somatosensory Cortical Reorganization after Unilateral Thoracic Spinal Cord Injury: A Longitudinal Functional Magnetic Resonance Imaging Study

    Directory of Open Access Journals (Sweden)

    Jia-Sheng Rao

    2013-01-01

    Full Text Available The effects of traumatic spinal cord injury (SCI on the changes in the central nervous system (CNS over time may depend on the dynamic interaction between the structural integrity of the spinal cord and the capacity of the brain plasticity. Functional magnetic resonance imaging (fMRI was used in a longitudinal study on five rhesus monkeys to observe cerebral activation during upper limb somatosensory tasks in healthy animals and after unilateral thoracic SCI. The changes in the spinal cord diameters were measured, and the correlations among time after the lesion, structural changes in the spinal cord, and primary somatosensory cortex (S1 reorganization were also determined. After SCI, activation of the upper limb in S1 shifted to the region which generally dominates the lower limb, and the rostral spinal cord transverse diameter adjacent to the lesion exhibited obvious atrophy, which reflects the SCI-induced changes in the CNS. A significant correlation was found among the time after the lesion, the spinal cord atrophy, and the degree of contralateral S1 reorganization. The results indicate the structural changes in the spinal cord and the dynamic reorganization of the cerebral activation following early SCI stage, which may help to further understand the neural plasticity in the CNS.

  3. Effects of electroconvulsive therapy on amygdala function in major depression - a longitudinal functional magnetic resonance imaging study.

    Science.gov (United States)

    Redlich, R; Bürger, C; Dohm, K; Grotegerd, D; Opel, N; Zaremba, D; Meinert, S; Förster, K; Repple, J; Schnelle, R; Wagenknecht, C; Zavorotnyy, M; Heindel, W; Kugel, H; Gerbaulet, M; Alferink, J; Arolt, V; Zwanzger, P; Dannlowski, U

    2017-09-01

    Electroconvulsive therapy (ECT) is one of the most effective treatments for severe depression. However, little is known regarding brain functional processes mediating ECT effects. In a non-randomized prospective study, functional magnetic resonance imaging data during the automatic processing of subliminally presented emotional faces were obtained twice, about 6 weeks apart, in patients with major depressive disorder (MDD) before and after treatment with ECT (ECT, n = 24). Additionally, a control sample of MDD patients treated solely with pharmacotherapy (MED, n = 23) and a healthy control sample (HC, n = 22) were obtained. Before therapy, both patient groups equally showed elevated amygdala reactivity to sad faces compared with HC. After treatment, a decrease in amygdala activity to negative stimuli was discerned in both patient samples indicating a normalization of amygdala function, suggesting mechanisms potentially unspecific for ECT. Moreover, a decrease in amygdala activity to sad faces was associated with symptomatic improvements in the ECT sample (r spearman = -0.48, p = 0.044), and by tendency also for the MED sample (r spearman = -0.38, p = 0.098). However, we did not find any significant association between pre-treatment amygdala function to emotional stimuli and individual symptom improvement, neither for the ECT sample, nor for the MED sample. In sum, the present study provides first results regarding functional changes in emotion processing due to ECT treatment using a longitudinal design, thus validating and extending our knowledge gained from previous treatment studies. A limitation was that ECT patients received concurrent medication treatment.

  4. A longitudinal study of neuromelanin-sensitive magnetic resonance imaging in Parkinson's disease.

    Science.gov (United States)

    Matsuura, Keita; Maeda, Masayuki; Tabei, Ken-Ichi; Umino, Maki; Kajikawa, Hiroyuki; Satoh, Masayuki; Kida, Hirotaka; Tomimoto, Hidekazu

    2016-10-28

    Neuromelanin-sensitive MR imaging (NMI) is an increasingly powerful tool for the diagnosis of Parkinson's disease (PD). This study was undertaken to evaluate longitudinal changes on NMI in PD patients. We examined longitudinal changes on NMI in 14 PD patients. The area and contrast ratio (CR) of the substantia nigra pars compacta (SNc) were comparatively analyzed. The total area and CR of the SNc upon follow-up NMI were significantly smaller than those on initial NMI (from 33.5±18.9 pixels and 6.35±2.86% to 21.5±16.7 pixels and 4.19±2.11%; Wilcoxon signed-rank test, pWilcoxon signed-rank test, p=0.002 and p=0.007, respectively). On a case-by-case basis, the area of the SNc invariably decreased upon follow-up NMI in all patients. We further demonstrated that the total area and CR of the SNc negatively correlated with disease duration (Pearson correlation coefficient, r=-0.63, p<0.001 and r=-0.41, p=0.031, respectively). In area analyses, our results demonstrated very high intraclass correlation coefficients for both intra- and inter-rater reliability. NMI is a useful and reliable tool for detecting neuropathological changes over time in PD patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  6. Longitudinal Evaluation of Muscle Composition Using Magnetic Resonance in 4 Boys With Duchenne Muscular Dystrophy: Case Series.

    Science.gov (United States)

    Senesac, Claudia R; Lott, Donovan J; Forbes, Sean C; Mathur, Sunita; Arpan, Ishu; Senesac, Emily S; Walter, Glenn A; Vandenborne, Krista

    2015-07-01

    Duchenne muscular dystrophy (DMD), an inherited recessive X chromosome-linked disease, is the most severe childhood form of muscular dystrophy. Boys with DMD experience muscle loss, with infiltration of intramuscular fat into muscles. This case series describes the progression of DMD in boys using magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS). Magnetic resonance results are then compared with an established functional timed test. Four boys with DMD and 4 healthy age-matched controls were chosen from a larger cohort. Boys with DMD were assessed at 4 time points over 2 years, with controls assessed at baseline only. Progression of the disease was documented by assessing the plantar flexors using MRI and MRS techniques and by assessing ambulation using the 30-Foot Fast Walk Test. Transverse relaxation time (T2) values were elevated in all boys with DMD at baseline. The lipid ratio increased rapidly as the disease progressed in 2 boys. Discrete changes in T2 in the other 2 boys with DMD indicated a slower disease progression. Magnetic resonance imaging and MRS allowed monitoring of the disease over all time periods regardless of ambulation status. The magnetic resonance data were collected with 2 different magnets at 2 different field strengths (1.5 and 3.0 T). Although we corrected for this difference, care must be taken in interpreting data when different image collection systems are used. This was a case series of 4 boys with DMD taken from a larger cohort study. Magnetic resonance imaging and MRS are objective, noninvasive techniques for measuring muscle pathology and can be used to detect discrete changes in both people who are ambulatory and those who are nonambulatory. These techniques should be considered when monitoring DMD progression and assessing efficacy of therapeutic interventions. © 2015 American Physical Therapy Association.

  7. Magnetic resonance imaging apparatus

    International Nuclear Information System (INIS)

    Ehnholm, G.J.

    1991-01-01

    This patent describes an electron spin resonance enhanced magnetic resonance (MR) imaging (ESREMRI) apparatus able to generate a primary magnetic field during periods of nuclear spin transition excitation and magnetic resonance signal detection. This allows the generation of ESREMRI images of a subject. A primary magnetic field of a second and higher value generated during periods of nuclear spin transition excitation and magnetic resonance signal detection can be used to generate conventional MR images of a subject. The ESREMRI and native MR images so generated may be combined, (or superimposed). (author)

  8. Reliability and sensitivity to change of the OMERACT rheumatoid arthritis magnetic resonance imaging score in a multireader, longitudinal setting

    DEFF Research Database (Denmark)

    Haavardsholm, ea; Østergaard, Mikkel; Kvan, NP

    2005-01-01

    OBJECTIVE: To assess the intra- and interreader reliability and the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) system on digital images of the wrist joints of patients with early or establi...

  9. Longitudinal in vivo magnetic resonance imaging studies in experimental allergic encephalomyelitis: effect of a neurotrophic treatment on cortical lesion development

    Energy Technology Data Exchange (ETDEWEB)

    Gispen, W.H. [Rudolf Magnus Institute for Neurosciences, Department of Medical Pharmacology, Medical Faculty, Utrecht University Utrecht (Netherlands); Nicolay, K. [Department of in vivo NMR, Bijvoet Center, Utrecht University Utrecht (Netherlands); Verhaagen, J. [Rudolf Magnus Institute for Neurosciences, Department of Medical Pharmacology, Medical Faculty, Utrecht University Utrecht (Netherlands); Muller, H.J. [Department of in vivo NMR, Bijvoet Center, Utrecht University Utrecht (Netherlands); Duckers, H.J. [Rudolf Magnus Institute for Neurosciences, Department of Medical Pharmacology, Medical Faculty, Utrecht University Utrecht (Netherlands)

    1997-02-14

    Proton magnetic resonance imaging enables non-invasive monitoring of lesion formation in multiple sclerosis and has an important role in assessing the potential effects of therapy. T2-weighted and short {tau} inversion recovery magnetic resonance imaging were used to assess the effect of a neurotrophic adrenocorticotrophic hormone{sub 4-9} analogue [H-Met(O{sub 2})-Glu-His-Phe-d-Lys-Phe-OH] on the volume of lesions in the brains of rats suffering from chronic experimental allergic encephalomyelitis, an animal equivalent of multiple sclerosis. Lesion volume was monitored during a five-month period. Magnetic resonance imaging indicated that treatment with the adrenocorticotrophic hormone{sub 4-9} analogue significantly reduced the lesion volume by 84 and 85% 10 and 20 weeks after lesion induction, respectively. Furthermore, peptide treatment significantly reduced chronic experimental allergic encephalomyelitis-related neurological symptoms during the chronic phase of the disease (week 3 until week 20 after lesion induction). Both functional and morphological recovery were considerably advanced by peptide treatment. Twenty weeks after lesion induction rats with chronic experimental allergic encephalomyelitis were killed for histological analysis, to correlate magnetic resonance imaging findings with morphological changes. The regions of abnormally high signal intensities on T2-weighted magnetic resonance images coincided with areas of demyelination and concomitant widespread inflammatory infiltration, oedema formation and enlarged ventricles.The improved neurological status and the 84% reduction in the lesion volume in the cerebrum of rats chronic experimental allergic encephalomyelitis point to the potential value of trophic peptides in the development of strategies for limiting the damage caused by central demyelinating lesions in syndromes such as multiple sclerosis. (Copyright (c) 1997 Elsevier Science B.V., Amsterdam. All rights reserved.)

  10. Longitudinal in vivo magnetic resonance imaging studies in experimental allergic encephalomyelitis: effect of a neurotrophic treatment on cortical lesion development

    International Nuclear Information System (INIS)

    Gispen, W.H.; Nicolay, K.; Verhaagen, J.; Muller, H.J.; Duckers, H.J.

    1997-01-01

    Proton magnetic resonance imaging enables non-invasive monitoring of lesion formation in multiple sclerosis and has an important role in assessing the potential effects of therapy. T2-weighted and short τ inversion recovery magnetic resonance imaging were used to assess the effect of a neurotrophic adrenocorticotrophic hormone 4-9 analogue [H-Met(O 2 )-Glu-His-Phe-d-Lys-Phe-OH] on the volume of lesions in the brains of rats suffering from chronic experimental allergic encephalomyelitis, an animal equivalent of multiple sclerosis. Lesion volume was monitored during a five-month period. Magnetic resonance imaging indicated that treatment with the adrenocorticotrophic hormone 4-9 analogue significantly reduced the lesion volume by 84 and 85% 10 and 20 weeks after lesion induction, respectively. Furthermore, peptide treatment significantly reduced chronic experimental allergic encephalomyelitis-related neurological symptoms during the chronic phase of the disease (week 3 until week 20 after lesion induction). Both functional and morphological recovery were considerably advanced by peptide treatment. Twenty weeks after lesion induction rats with chronic experimental allergic encephalomyelitis were killed for histological analysis, to correlate magnetic resonance imaging findings with morphological changes. The regions of abnormally high signal intensities on T2-weighted magnetic resonance images coincided with areas of demyelination and concomitant widespread inflammatory infiltration, oedema formation and enlarged ventricles.The improved neurological status and the 84% reduction in the lesion volume in the cerebrum of rats chronic experimental allergic encephalomyelitis point to the potential value of trophic peptides in the development of strategies for limiting the damage caused by central demyelinating lesions in syndromes such as multiple sclerosis. (Copyright (c) 1997 Elsevier Science B.V., Amsterdam. All rights reserved.)

  11. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  12. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  13. Nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Ethier, R.; Melanson, D.; Peters, T.M.

    1983-01-01

    Ten years following computerized tomography, a new technique called nuclear magnetic resonance revolutionizes the field of diagnostic imaging. A major advantage of nuclear magnetic resonance is that the danger of radiation is non-existent as compared to computerized tomography. When parts of the human body are subject to radio-frequencies while in a fixed magnetic field, its most detailed structures are revealed. The quality of images, the applications, as well as the indications are forever increasing. Images obtained at the level of the brain and spinal cord through nuclear magnetic resonance supercede those obtained through computerized tomography. Hence, it is most likely that myelography, along with pneumoencephalography will be eliminated as a diagnostic means. It is without a doubt that nuclear magnetic resonance is tomorrow's computerized tomography [fr

  14. Magnetic resonance tomography in syringomyelia

    International Nuclear Information System (INIS)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.; Staedtisches Rudolf-Virchow Krankenhaus, Berlin

    1985-01-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness. (orig.) [de

  15. The entire dural sinus tree is compressed in patients with idiopathic intracranial hypertension: a longitudinal, volumetric magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, Axel; Bindeballe, Jan; Riedel, Christian; Jansen, Olav [University Clinic of Schleswig-Holstein Campus Kiel, Department of Neuroradiology, Kiel (Germany); Baalen, Andreas van [University Clinic of Schleswig-Holstein Campus Kiel, Department of Neuropediatrics, Kiel (Germany); Bartsch, Thorsten [University Clinic of Schleswig-Holstein Campus Kiel, Department of Neurology, Kiel (Germany); Doerner, Lutz [University Clinic of Schleswig-Holstein Campus Kiel, Department of Neurosurgery, Kiel (Germany)

    2012-01-15

    The objective of this study was to explore the volumetric alterations of dural sinuses in patients with idiopathic intracranial hypertension (IIH). Standardized cranial magnetic resonance imaging (MRI) was used in 17 patients prior to and following treatment of IIH and in seven controls. Magnetic resonance venographies (MRV) were employed for (a) judgement of circumscript dural sinus stenoses and (b) computation of sinus volumes. Cross-sectional areas (CSA) of the superior sagittal sinuses (SSS) were measured on T2-weighted images. Results of the initial MRIs were compared to those on follow-up MRIs and to results of controls. Stenoses of the transverse sinuses (TS) resulting in cranial venous outflow obstruction (CVOO) were present in 15/17 (88%) patients, normalizing in 7/15 cases (47%) after treatment of IIH. CVOO was not detected in the control group. Segmentation of MRV revealed decreased dural sinus volumes in patients with IIH as compared to controls (P = 0.018). Sinus volumes increased significantly with normalization of intracranial pressure independent from disappearing of TS stenoses (P = 0.007). The CSA of the SSS were normal on the initial MRIs of patients with IIH and increased on follow-up after treatment (P < 0.001). However, volumetries displayed overlap in patients and controls. Patients with IIH not only exhibit bilateral stenoses of the TS as has been reported, but volume changes of their entire dural sinus system also occur. The potential etiopathological and diagnostic roles of these changes are discussed. (orig.)

  16. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Magnetic resonance (MR) defecography is a special ... with you. top of page What are the benefits vs. risks? Benefits MR defecography helps assess pelvic ...

  17. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  18. Magnetic Resonance Cholangiopancreatography (MRCP)

    Science.gov (United States)

    ... radio waves and a computer to evaluate the liver, gallbladder, bile ducts, pancreas and pancreatic duct for disease. It is ... of the hepatobiliary and pancreatic systems, including the liver, gallbladder, bile ducts, pancreas and pancreatic duct . Magnetic resonance imaging (MRI) ...

  19. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  20. Magnetic resonance angiography

    Science.gov (United States)

    ... Saunders; 2015:chap 17. Litt H, Carpenter JP. Magnetic resonance imaging. In: Cronenwett JL, Johnston KW, eds. Rutherford's Vascular Surgery . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap ...

  1. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Robertson, Angus

    1990-01-01

    An assessment is made of the clinical benefits of expensive diagnostic technology, such as the magnetic resonance imaging. It is concluded that to most radiologists, magnetic resonance imaging has a definite place in the diagnostic scenario, especially for demonstrating central nervous system lesions in multiple sclerosis. While it is recognized that medical and financial resources are limited, it is emphasised that the cost to society must be balanced against the patient benefit. 17 refs

  2. Nuclear magnetic resonance gyroscope

    International Nuclear Information System (INIS)

    Grover, B.C.

    1984-01-01

    A nuclear magnetic resonance gyro using two nuclear magnetic resonance gases, preferably xenon 129 and xenon 131, together with two alkaline metal vapors, preferably rubidium, potassium or cesium, one of the two alkaline metal vapors being pumped by light which has the wavelength of that alkaline metal vapor, and the other alkaline vapor being illuminated by light which has the wavelength of that other alkaline vapor

  3. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  4. Laser magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Ferrari, C.A.

    1985-01-01

    The technique of laser resonance magnetic resonance allows one to study the high-resolution spectroscopy of transient paramagnetic species, viz, atoms, radicals, and molecular ions. This article is a brief exposition of the method, describing the principles, instrumentation and applicability of the IR and FIR-LMR and shows results of HF + . (Author) [pt

  5. Nuclear Magnetic Resonance Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Nuclear Magnetic Resonance Spectroscopy. Susanta Das. General Article Volume 9 Issue 1 January 2004 pp 34-49. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/009/01/0034-0049. Keywords.

  6. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Magnetic resonance imaging (MRI) is a new and innovative technique that affords anatomic images in multiple planes and that may provide information about tissue characterization. The magnetic resonance images are obtained by placing the patient or the area of interest within a powerful, highly uniform, static magnetic field. Magnetized protons (hydrogen nuclei) within the patient align like small magnets in this field. Radiofrequency pulses are then used to create an oscillating magnetic field perpendicular to the main field. Magnetic resonance images differ from those produced by x-rays: the latter are associated with absorption of x-ray energy while magnetic resonance images are based on proton density and proton relaxation dynamics. Proton characteristics vary according to the tissue under examination and reflect its physical and chemical properties. To resolve issues regarding safety and efficacy, the Warren Grant Magnuson Clinical Center and the Office of Medical Applications of Research of the National Institutes of Health (NIH) convened a consensus conference about MRI Oct 26 through 28, 1987. At the NIH, the Consensus Development Conference brings together investigators in the biomedical sciences, clinical investigators, practicing physicians, and consumer and special interest groups to make a scientific assessment of technologies, including drugs, devices, and procedures, and to seek agreement on their safety and effectiveness

  7. Nuclear magnetic resonance apparatus

    International Nuclear Information System (INIS)

    Lambert, R.

    1991-01-01

    In order to include the effect of a magnetic object in a subject under investigation, Nuclear Magnetic Resonance (NMR) apparatus is operable at more than one radio frequency (RF) frequency. The apparatus allows normal practice as far as obtaining an NMR response or image from a given nuclear species is concerned, but, in addition, interrogates the nuclear spin system at a frequency which is different from the resonance frequency normally used for the given nuclear species, as determined from the applied magnetic field. The magnetic field close to a magnetised or magnetisable object is modified and the given nuclear species gives a response at the different frequency. Thus detection of a signal at the frequency indicates the presence of the chosen nuclei close to the magnetised or magnetisable object. Applications include validation of an object detection or automatic shape inspection system in the presence of magnetic impurities, and the detection of magnetic particles which affect measurement of liquid flow in a pipe. (author)

  8. The Combined Quantification and Interpretation of Multiple Quantitative Magnetic Resonance Imaging Metrics Enlightens Longitudinal Changes Compatible with Brain Repair in Relapsing-Remitting Multiple Sclerosis Patients.

    Science.gov (United States)

    Bonnier, Guillaume; Maréchal, Benedicte; Fartaria, Mário João; Falkowskiy, Pavel; Marques, José P; Simioni, Samanta; Schluep, Myriam; Du Pasquier, Renaud; Thiran, Jean-Philippe; Krueger, Gunnar; Granziera, Cristina

    2017-01-01

    Quantitative and semi-quantitative MRI (qMRI) metrics provide complementary specificity and differential sensitivity to pathological brain changes compatible with brain inflammation, degeneration, and repair. Moreover, advanced magnetic resonance imaging (MRI) metrics with overlapping elements amplify the true tissue-related information and limit measurement noise. In this work, we combined multiple advanced MRI parameters to assess focal and diffuse brain changes over 2 years in a group of early-stage relapsing-remitting MS patients. Thirty relapsing-remitting MS patients with less than 5 years disease duration and nine healthy subjects underwent 3T MRI at baseline and after 2 years including T1, T2, T2* relaxometry, and magnetization transfer imaging. To assess longitudinal changes in normal-appearing (NA) tissue and lesions, we used analyses of variance and Bonferroni correction for multiple comparisons. Multivariate linear regression was used to assess the correlation between clinical outcome and multiparametric MRI changes in lesions and NA tissue. In patients, we measured a significant longitudinal decrease of mean T2 relaxation times in NA white matter ( p  = 0.005) and a decrease of T1 relaxation times in the pallidum ( p  decrease in T1 relaxation time ( p -value  0.4, p  < 0.05). In summary, the combination of multiple advanced MRI provided evidence of changes compatible with focal and diffuse brain repair at early MS stages as suggested by histopathological studies.

  9. Longitudinal Magnetic Resonance Imaging (MRI) Analysis of the Developmental Changes of Tourette Syndrome Reveal Reduced Diffusion in the Cortico-Striato-Thalamo-Cortical Pathways

    DEFF Research Database (Denmark)

    Debes, Nanette; Jeppesen, Signe; Raghava, Jayachandra Mitta

    2015-01-01

    There is evidence that cortico-striato-thalamo-cortical pathways are involved in Tourette syndrome. We performed a longitudinal imaging study in 22 patients and 21 healthy controls in order to examine the development of tics and its correlation with magnetic resonance imaging (MRI) findings....... Patients were divided in a group with persisting and a group with remission of tics. We found a decrease in volume of left putamen in controls, but not in patients. We found changes in mean diffusivity between patients and controls in right caudate nucleus, thalamus, and frontal lobe. In contrast...... to controls, parallel and perpendicular diffusivity decreased in patients and were most pronounced in the patients with persisting tics compared to those with remission. The findings suggest that the development of the brain in patients with remission resembles the normal development more than in patients...

  10. Nuclear magnetic resonance scattering

    International Nuclear Information System (INIS)

    Young, I.R.

    1985-01-01

    A nuclear magnetic resonance apparatus is described including a magnet system which is capable of providing a steady magnetic field along an axis, and is constructed so as to define a plurality of regions along the axis in each of which the field is substantially homogeneous so that in each region an imaging operation may be separately carried out. Iron shields increase the field homogeneity. In use, each patient lies on a wheeled trolley which is provided with magnetic field gradient coils and an RF coil system, some of the coils being movable to facilitate positioning of the patient, and there are terminals for connection to a common computing and control facility. (author)

  11. Magnetic resonance annual, 1988

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1987-01-01

    This book features reviews of high-resolution MRI of the knee, MRI of the normal and ischmeic hip, MRI of the heart, and temporomandibular joint imaging, as well as thorough discussion on artifacts in magnetic resonance imaging. Contributors consider the clinical applications of gadolinium-DTPA in magnetic resonance imaging and the clinical use of partial saturation and saturation recovery sequences. Timely reports assess the current status of rapid MRI and describe a new rapid gated cine MRI technique. Also included is an analysis of cerebrospinal fluid flow effects during MRI of the central nervous system

  12. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  13. Changes on magnetic resonance tomography in the knee joints of marathon runners: a 10-year longitudinal study

    International Nuclear Information System (INIS)

    Krampla, Wolfgang W.; Newrkla, Stephan P.; Hruby, Walter F.; Kroener, Andreas H.

    2008-01-01

    The aim of the study was to evaluate long-term damage in the internal structures of the knee joints of recreational long-distance runners. Ten years after their participation in a baseline study concerning their knee joints, seven long-distance runners and one who had given up long-distance running were invited to participate in a repeat magnetic resonance imaging (MRI) investigation. The same evaluation criteria and the same technical equipment were used, and the results of the two investigations were compared. No adverse long-term consequences were observed in six of the seven active runners, regardless of pre-existing damage at the baseline investigation. In one case the arthrotic changes were progressive in nature. The person who had given up running presented with severe deterioration of the internal structures of the knee joint. Non-physiological maximal loads secondary to the marathon race do not cause any permanent damage in the internal structures of the knee joint in individuals without significant pre-existing damage. A disposition for premature arthrosis was not registered in the population investigated. A protective value of long distance running on the internal structures of the knee joint is discussed. (orig.)

  14. Changes on magnetic resonance tomography in the knee joints of marathon runners: a 10-year longitudinal study

    Energy Technology Data Exchange (ETDEWEB)

    Krampla, Wolfgang W.; Newrkla, Stephan P.; Hruby, Walter F. [Danube Hospital, Radiology Department, Vienna (Austria); Kroener, Andreas H. [Danube Hospital, Department of Orthopedic Surgery, Vienna (Austria)

    2008-07-15

    The aim of the study was to evaluate long-term damage in the internal structures of the knee joints of recreational long-distance runners. Ten years after their participation in a baseline study concerning their knee joints, seven long-distance runners and one who had given up long-distance running were invited to participate in a repeat magnetic resonance imaging (MRI) investigation. The same evaluation criteria and the same technical equipment were used, and the results of the two investigations were compared. No adverse long-term consequences were observed in six of the seven active runners, regardless of pre-existing damage at the baseline investigation. In one case the arthrotic changes were progressive in nature. The person who had given up running presented with severe deterioration of the internal structures of the knee joint. Non-physiological maximal loads secondary to the marathon race do not cause any permanent damage in the internal structures of the knee joint in individuals without significant pre-existing damage. A disposition for premature arthrosis was not registered in the population investigated. A protective value of long distance running on the internal structures of the knee joint is discussed. (orig.)

  15. Imaging by magnetic resonance

    International Nuclear Information System (INIS)

    Duroure, J.F.; Serpolay, H.; Vallens, D.

    1995-01-01

    Here are described the advanced technology for nuclear magnetic resonance imaging: reduction of acquisition times, and rebuilding times, images quality improvement. The tendency is to open the machines at low and middle field, on a market being at 10% of NMR I sales, with economical, scientifical and ergonomic reasons broadly developed by constructors

  16. Magnetic resonance fingerprinting.

    Science.gov (United States)

    Ma, Dan; Gulani, Vikas; Seiberlich, Nicole; Liu, Kecheng; Sunshine, Jeffrey L; Duerk, Jeffrey L; Griswold, Mark A

    2013-03-14

    Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.

  17. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  18. Nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Rueterjans, H.

    1987-01-01

    Contributions by various authors who are working in the field of NMR imaging present the current status and the perspectives of in-vivo nuclear magnetic resonance spectroscopy, explaining not only the scientific and medical aspects, but also technical and physical principles as well as questions concerning practical organisation and training, and points of main interest for further research activities. (orig./TRV) [de

  19. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  1. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  2. Magnetic resonance of phase transitions

    CERN Document Server

    Owens, Frank J; Farach, Horacio A

    1979-01-01

    Magnetic Resonance of Phase Transitions shows how the effects of phase transitions are manifested in the magnetic resonance data. The book discusses the basic concepts of structural phase and magnetic resonance; various types of magnetic resonances and their underlying principles; and the radiofrequency methods of nuclear magnetic resonance. The text also describes quadrupole methods; the microwave technique of electron spin resonance; and the Mössbauer effect. Phase transitions in various systems such as fluids, liquid crystals, and crystals, including paramagnets and ferroelectrics, are also

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  8. The deleterious effects of arteriovenous fistula-creation on the cardiovascular system: a longitudinal magnetic resonance imaging study

    Directory of Open Access Journals (Sweden)

    Dundon BK

    2014-09-01

    Full Text Available Benjamin K Dundon,1–3 Kim Torpey,3 Adam J Nelson,1 Dennis TL Wong,1,2 Rae F Duncan,1 Ian T Meredith,2 Randall J Faull,1,3 Stephen G Worthley,1,4 Matthew I Worthley1,4 1Cardiology Department, Royal Adelaide Hospital, Central Adelaide Local Health Network, Discipline of Medicine, University of Adelaide, Adelaide, SA, Australia; 2Monash Cardiovascular Research Centre, MonashHEART, Monash Health, Melbourne, Vic, Australia; 3Central Northern Renal and Transplantation Service, Royal Adelaide Hospital, Central Adelaide Local Health Network, Adelaide, SA, Australia; 4South Australian Health and Medical Research Institute, Adelaide, SA, Australia Aim: Arteriovenous fistula-formation remains critical for the provision of hemodialysis in end-stage renal failure patients. Its creation results in a significant increase in cardiac output, with resultant alterations in cardiac stroke volume, systemic blood flow, and vascular resistance. The impact of fistula-formation on cardiac and vascular structure and function has not yet been evaluated via "gold standard" imaging techniques in the modern era of end-stage renal failure care. Methods: A total of 24 patients with stage 5 chronic kidney disease undergoing fistula-creation were studied in a single-arm pilot study. Cardiovascular magnetic resonance imaging was undertaken at baseline, and prior to and 6 months following fistula-creation. This gold standard imaging modality was used to evaluate, via standard brachial flow-mediated techniques, cardiac structure and function, aortic distensibility, and endothelial function. Results: At follow up, left ventricular ejection fraction remained unchanged, while mean cardiac output increased by 25.0% (P<0.0001. Significant increases in left and right ventricular end-systolic volumes (21% [P=0.014] and 18% [P<0.01], left and right atrial area (11% [P<0.01] and 9% [P<0.01], and left ventricular mass were observed (12.7% increase (P<0.01. Endothelial

  9. Magnetic resonance instrumentation

    International Nuclear Information System (INIS)

    Bell, R.A.

    1987-01-01

    Magnetic resonance (MR), while opening new vistas to diagnostic medicine, utilizes equipment that is unfamiliar to most clinicians. Beyond learning to cope with new terms, such as spin-echo, T1, T2, and spin density, health care professionals are faced with the inclusion of magnetic and radiofrequency effects in their facilities produced by a complex array of devices. It is the purpose of this chapter to outline the components of an MR imaging system, to discuss their functions, and to note the variations in equipment commercially available

  10. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sigal, R.

    1988-01-01

    This book is an introduction to magnetic resonance imaging (MRI). The basic principles for the interpretation of MR images are developed. The book is divided into five chapters: introduction, tissue, parameters, acquisition parameters, contribution to diagnosis, and practical management of an MR examination. Eight exercises allow the reader to test the knowledge he has acquired. Signal localization and MR artefacts are reviewed in an appendix

  11. Magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Takavar A

    1993-04-01

    Full Text Available Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I, a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D. factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  12. Magnetic resonance imaging (MRI)

    OpenAIRE

    Takavar A

    1993-01-01

    Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  14. The Combined Quantification and Interpretation of Multiple Quantitative Magnetic Resonance Imaging Metrics Enlightens Longitudinal Changes Compatible with Brain Repair in Relapsing-Remitting Multiple Sclerosis Patients

    Directory of Open Access Journals (Sweden)

    Guillaume Bonnier

    2017-09-01

    Full Text Available ObjectiveQuantitative and semi-quantitative MRI (qMRI metrics provide complementary specificity and differential sensitivity to pathological brain changes compatible with brain inflammation, degeneration, and repair. Moreover, advanced magnetic resonance imaging (MRI metrics with overlapping elements amplify the true tissue-related information and limit measurement noise. In this work, we combined multiple advanced MRI parameters to assess focal and diffuse brain changes over 2 years in a group of early-stage relapsing-remitting MS patients.MethodsThirty relapsing-remitting MS patients with less than 5 years disease duration and nine healthy subjects underwent 3T MRI at baseline and after 2 years including T1, T2, T2* relaxometry, and magnetization transfer imaging. To assess longitudinal changes in normal-appearing (NA tissue and lesions, we used analyses of variance and Bonferroni correction for multiple comparisons. Multivariate linear regression was used to assess the correlation between clinical outcome and multiparametric MRI changes in lesions and NA tissue.ResultsIn patients, we measured a significant longitudinal decrease of mean T2 relaxation times in NA white matter (p = 0.005 and a decrease of T1 relaxation times in the pallidum (p < 0.05, which are compatible with edema reabsorption and/or iron deposition. No longitudinal changes in qMRI metrics were observed in controls. In MS lesions, we measured a decrease in T1 relaxation time (p-value < 2.2e−16 and a significant increase in MTR (p-value < 1e−6, suggesting repair mechanisms, such as remyelination, increased axonal density, and/or a gliosis. Last, the evolution of advanced MRI metrics—and not changes in lesions or brain volume—were correlated to motor and cognitive tests scores evolution (Adj-R2 > 0.4, p < 0.05. In summary, the combination of multiple advanced MRI provided evidence of changes compatible with focal and diffuse brain repair at

  15. Introduction lecture to magnetic resonance

    International Nuclear Information System (INIS)

    Conard, J.

    1980-01-01

    This lecture deals with all that is common either to electron paramagnetic resonance (E.P.R.) or to nuclear magnetic resonance (N.M.R.). It will present, in an as elementary form as possible, the main concepts used in magnetic resonance emphasizing some aspects, specific for interface science. (orig./BHO)

  16. Advanced Nuclear Magnetic Resonance

    OpenAIRE

    Alonso, Diego A.

    2014-01-01

    Transparencias en inglés de la asignatura "Resonancia Magnética Nuclear Avanzada" (Advanced Nuclear Magnetic Resonance) (36643) que se imparte en el Máster de Química Médica como asignatura optativa de 3 créditos ECTS. En esta asignatura se completa el estudio iniciado en la asignatura de quinto curso de la licenciatura en Química "Determinación estructural" (7448) y en la del Grado de Química de tercer curso "Determinación estructural de los compuestos orgánicos" (26030) en lo referente a té...

  17. Cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Elster, A.D.

    1988-01-01

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes

  18. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Bendszus, Martin; Haehnel, Stefan

    2016-01-01

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  19. Nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cremin, B.J.

    1981-01-01

    Recent advances in diagnostic imaging, have been the medical application of nuclear magnetic resonance (NMR). It's been used to study the structure of various compounds in chemistry and physics, and in the mid-1970 to produce images of rabbits and eventually of the human hand and head. The images are produced by making use of the nuclear magnetization of the hydrogen ion, or proton, that is present in biological material to record the density distribution of protons in cellular water and lipids. An exploration of the end-results of complicated free induction decay signals, that have been digitized and frequency-analysed by mathematical computerized techniques to produce an image of tissue density, is given. At present NMR produces images comparable to those of early computed tomography

  20. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  1. Nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Rabenstein, D.L.; Guo, W.

    1988-01-01

    Nuclear magnetic resonance (NMR) spectroscopy is one of the most widely used instrumental methods, with applications ranging from the characterization of pure compounds by high-resolution NMR to the diagnosis of disease by magnetic resonance imaging (MRI). To give some idea of the wide-spread use of NMR, a computer search for the period 1985-1987 turned up over 500 books and review articles and over 7000 literature citations, not including papers in which NMR was used together with other spectroscopic methods for the routine identification of organic compounds. Consequently, they have by necessity been somewhat selective in the topics they have chosen to cover and in the articles they have cited. In this review, which covers the published literature for the approximate period Sept 1985-Aug 1987, they have focused on new developments and applications of interest to the chemist. First they review recent developments in instrumentation and techniques. Although there have not been any major break-throughs in NMR instrumentation during the past two years, significant refinements have been reported which optimize instrumentation for the demanding multiple pulse experiments in routine use today. Next they review new developments in methods for processing NMR data, followed by reviews of one-dimensional and two-dimensional NMR experiments

  2. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... immediately after the exam. A few patients experience side effects from the contrast material, including nausea and local ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  6. Longitudinal microvascularity in achilles tendinopathy (power doppler ultrasound, magnetic resonance imaging time-intensity curves and the Victorian Institute of Sport Assessment-Achilles questionnaire): a pilot study

    International Nuclear Information System (INIS)

    Richards, Paula J.; McCall, Iain W.; Day, Christopher; Belcher, John; Maffulli, Nicola

    2010-01-01

    To evaluate the imaging of the natural history of Achilles tendinopathy microvascularisation in comparison with symptoms, using a validated disease-specific questionnaire [the Victorian Institute of Sport Assessment-Achilles (VISA-A)]. A longitudinal prospective pilot study of nine patients with post-contrast magnetic resonance imaging (MRI), time-intensity curve (TIC) enhancement, ultrasound (US) and power Doppler (PD) evaluation of tendinopathy of the mid-Achilles tendon undergoing conservative management (eccentric exercise) over 1 year. There were five men and four women [mean age 47 (range 30-62) years]. Six asymptomatic tendons with normal US and MRI appearance showed less enhancement than the tibial metaphysis did and showed a flat, constant, but very low rate of enhancement in the bone and Achilles tendon (9-73 arbitrary TIC units). These normal Achilles tendons on imaging showed a constant size throughout the year (mean 4.9 mm). At baseline the TIC enhancement in those with tendinopathy ranged from 90 arbitrary units to 509 arbitrary units. Over time, 11 abnormal Achilles tendons, whose symptoms settled, were associated with a reduction in MRI enhancement mirrored by a reduction in the number of vessels on power Doppler (8.0 to 2.7), with an improvement in morphology and a reduction in tendon size (mean 15-10.6 mm). One tendon did not change its abnormal imaging features, despite improving symptoms. Two patients developed contralateral symptoms and tendinopathy, and one had more abnormal vascularity on power Doppler and higher MRI TIC peaks in the asymptomatic side. In patient with conservatively managed tendinopathy of the mid-Achilles tendon over 1 year there was a reduction of MRI enhancement and number of vessels on power Doppler, followed by morphological improvements and a reduction in size. Vessels per se related to the abnormal morphology and size of the tendon rather than symptoms. Symptoms improve before the Achilles size reduces and the

  7. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    Science.gov (United States)

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  8. Predictors of long-term pain and disability in patients with low back pain investigated by magnetic resonance imaging: A longitudinal study

    Directory of Open Access Journals (Sweden)

    Sampson Madeleine

    2011-10-01

    Full Text Available Abstract Background It is possible that clinical outcome of low back pain (LBP differs according to the presence or absence of spinal abnormalities on magnetic resonance imaging (MRI, in which case there could be value in using MRI findings to refine case definition of LBP in epidemiological research. We therefore conducted a longitudinal study to explore whether spinal abnormalities on MRI for LBP predict prognosis after 18 months. Methods A consecutive series of patients aged 20-64 years, who were investigated by MRI because of mechanical LBP (median duration of current episode 16.2 months, were identified from three radiology departments, and those who agreed completed self-administered questionnaires at baseline and after a mean follow-up period of 18.5 months (a mean of 22.2 months from MRI investigation. MRI scans were assessed blind to other clinical information, according to a standardised protocol. Associations of baseline MRI findings with pain and disability at follow-up, adjusted for treatment and for other potentially confounding variables, were assessed by Poisson regression and summarised by prevalence ratios (PRs with their 95% confidence intervals (CIs. Results Questionnaires were completed by 240 (74% of the patients who had agreed to be followed up. Among these 111 men and 129 women, 175 (73% reported LBP in the past four weeks, 89 (37% frequent LBP, and 72 (30% disabling LBP. In patients with initial disc degeneration there was an increased risk of frequent (PR 1.3, 95%CI 1.0-1.9 and disabling LBP (PR 1.7, 95%CI 1.1-2.5 at follow-up. No other associations were found between MRI abnormalities and subsequent outcome. Conclusions Our findings suggest that the MRI abnormalities examined are not major predictors of outcome in patients with LBP. They give no support to the use of MRI findings as a way of refining case definition for LBP in epidemiological research.

  9. Magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Meyerhoff, D.J.; Weiner, M.W.

    1989-01-01

    A major function of the liver is regulation of carbohydrate, lipid, and nitrogen metabolism. Food is absorbed by the intestines and transported to the liver by the portal circulation. Substrates are metabolized and stored in the liver to maintain optimal blood concentrations of glucose and lipids. Ammonia generated in the gastrointestinal tract is converted to urea in the liver by the urea cycle. Various forms of liver disease are associated with disorders of carbohydrate, fat, and nitrogen metabolism. Therefore the ability to characterize liver metabolism noninvasively is of potential diagnostic value. Magnetic resonance spectroscopy (MRS) provides information about tissue metabolism by measuring concentrations of metabolites. However, to determine the anatomic location from which spectroscopic signals are derived, MRS could be performed in conjunction with MRI. This paper summarizes the current experience with spectroscopy ion animal models of human disease and reviews the clinical experience with hepatic MRS to date

  10. Magnetic resonance in neuroborreliosis

    International Nuclear Information System (INIS)

    Ustymowicz, A.; Zajkowska, J.

    2003-01-01

    Magnetic resonance (MR) is commonly used in diagnosing infections of the central nervous system. The aim of the study is to evaluate central nervous system changes in neuroborreliosis patients. MR examinations were performed in 44 patients with clinical symptoms, epidemiology and laboratory tests results of neuroborreliosis. Abnormalities were detected in 22 patients. Most of them presented cortico-subcortical atrophy (86%). In 9 cases foci of increased signal in T2-weighted and FLAIR images were observed in white matter. They were single or multiple, located subcorticaly and paraventriculary. In 2 subjects areas of increased signal were found in the brain stem. Central nervous system abnormalities detected with MR are not specific for Lyme disease. They can suggest demyelinating lesions and/or gliosis observed in many nervous system disorders (SM, ADEM, lacunar infarcts). (author)

  11. Cine magnetic resonance

    International Nuclear Information System (INIS)

    Higgins, C.B.; Sechtem, U.P.; Pflugfelder, P.

    1987-01-01

    Cine magnetic resonance (MR) is a fast MR imaging process with referencing of the imaging data to the electrocardiogram (ECG) so that images corresponding to 21-msec segments of the cardiac cycle are acquired. A series of such images, each corresponding to a 21-msec segment of the cardiac cycle, can be laced together for viewing in the cine format at a framing rate of 20 to 40 frames per second. Since cine angiograms of the heart are usually done at 30 frames per second, this technique achieves a temporal resolution adequate for the evluation of central cardiovascular function. The major application of this technique is to depict central cardiovascular function and blood flow

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... for an MRI exam contains a metal called gadolinium . Gadolinium can be used in patients with iodine ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, ... Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses ... identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ...

  15. Magnetic resonance of low dimensional magnetic solids

    Energy Technology Data Exchange (ETDEWEB)

    Gatteschi, D.; Ferraro, F.; Sessoli, R. (Florence Univ. (Italy))

    1994-06-01

    The utility of EPR and NMR in the study of low-dimensional magnetic solids is shown. A short summary of the basis of magnetic resonance in these systems is reported, and the importance of spin-diffusion and magnetic anisotropy evidenced. Some results from experiments on metal-radical chains and clusters are presented. (authors). 37 refs., 7 figs.

  16. Magnetic resonance of low dimensional magnetic solids

    International Nuclear Information System (INIS)

    Gatteschi, D.; Ferraro, F.; Sessoli, R.

    1994-01-01

    The utility of EPR and NMR in the study of low-dimensional magnetic solids is shown. A short summary of the basis of magnetic resonance in these systems is reported, and the importance of spin-diffusion and magnetic anisotropy evidenced. Some results from experiments on metal-radical chains and clusters are presented. (authors). 37 refs., 7 figs

  17. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  18. Magnetic resonance imaging methodology

    International Nuclear Information System (INIS)

    Moser, Ewald; Stadlbauer, Andreas; Windischberger, Christian; Quick, Harald H.; Ladd, Mark E.

    2009-01-01

    Magnetic resonance (MR) methods are non-invasive techniques to provide detailed, multi-parametric information on human anatomy, function and metabolism. Sensitivity, specificity, spatial and temporal resolution may, however, vary depending on hardware (e.g., field strength, gradient strength and speed) and software (optimised measurement protocols and parameters for the various techniques). Furthermore, multi-modality imaging may enhance specificity to better characterise complex disease patterns. Positron emission tomography (PET) is an interesting, largely complementary modality, which might be combined with MR. Despite obvious advantages, combining these rather different physical methods may also pose challenging problems. At this early stage, it seems that PET quality may be preserved in the magnetic field and, if an adequate detector material is used for the PET, MR sensitivity should not be significantly degraded. Again, this may vary for the different MR techniques, whereby functional and metabolic MR is more susceptible than standard anatomical imaging. Here we provide a short introduction to MR basics and MR techniques, also discussing advantages, artefacts and problems when MR hardware and PET detectors are combined. In addition to references for more detailed descriptions of MR fundamentals and applications, we provide an early outlook on this novel and exciting multi-modality approach to PET/MR. (orig.)

  19. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  20. Right Ventricular Volumes and Systolic Function by Cardiac Magnetic Resonance and the Impact of Sex, Age, and Obesity in a Longitudinally Followed Cohort Free of Pulmonary and Cardiovascular Disease: The Framingham Heart Study.

    Science.gov (United States)

    Foppa, Murilo; Arora, Garima; Gona, Philimon; Ashrafi, Arman; Salton, Carol J; Yeon, Susan B; Blease, Susan J; Levy, Daniel; O'Donnell, Christopher J; Manning, Warren J; Chuang, Michael L

    2016-03-01

    Cardiac magnetic resonance is uniquely well suited for noninvasive imaging of the right ventricle. We sought to define normal cardiac magnetic resonance reference values and to identify the main determinants of right ventricular (RV) volumes and systolic function using a modern imaging sequence in a community-dwelling, longitudinally followed cohort free of clinical cardiovascular and pulmonary disease. The Framingham Heart Study Offspring cohort has been followed since 1971. We scanned 1794 Offspring cohort members using steady-state free precession cardiac magnetic resonance and identified a reference group of 1336 adults (64±9 years, 576 men) free of prevalent cardiovascular and pulmonary disease. RV trabeculations and papillary muscles were considered cavity volume. Men had greater RV volumes and cardiac output before and after indexation to body size (all Pheart rate account for most of the variability in RV volumes and function in this community-dwelling population. We report sex-specific normative values for RV measurements among principally middle-aged and older adults. RV ejection fraction is greater in women. RV volumes increase with body size, are greater in men, and are smaller in older people. Body surface area seems to be appropriate for indexation of cardiac magnetic resonance-derived RV volumes. © 2016 American Heart Association, Inc.

  1. Low field magnetic resonance imaging

    Science.gov (United States)

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  2. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  3. Noncontrast Magnetic Resonance Lymphography.

    Science.gov (United States)

    Arrivé, Lionel; Derhy, Sarah; El Mouhadi, Sanaâ; Monnier-Cholley, Laurence; Menu, Yves; Becker, Corinne

    2016-01-01

    Different imaging techniques have been used for the investigation of the lymphatic channels and lymph glands. Noncontrast magnetic resonance (MR) lymphography has significant advantages in comparison with other imaging modalities. Noncontrast MR lymphography uses very heavily T2-weighted fast spin echo sequences which obtain a nearly complete signal loss in tissue background and specific display of lymphatic vessels with a long T2 relaxation time. The raw data can be processed with different algorithms such as maximum intensity projection algorithm to obtain an anatomic representation. Standard T2-weighted MR images easily demonstrate the location of edema. It appears as subcutaneous infiltration of soft tissue with a classical honeycomb pattern. True collection around the muscular area may be demonstrated in case of severe lymphedema. Lymph nodes may be normal in size, number, and signal intensity; in other cases, lymph nodes may be smaller in size or number of lymph nodes may be restricted. MR lymphography allows a classification of lymphedema in aplasia (no collecting vessels demonstrated); hypoplasia (a small number of lymphatic vessels), and numerical hyperplasia or hyperplasia (with an increased number of lymphatic vessels of greater and abnormal diameter). Noncontrast MR lymphography is a unique noninvasive imaging modality for the diagnosis of lymphedema. It can be used for positive diagnosis, differential diagnosis, and specific evaluation of lymphedema severity. It may also be used for follow-up evaluation after treatment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Magnetic resonance imaging. 1

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Roos, A.A. de; Doornbos, J.; Dijkman, P.R.M. van; Matheijssen, N.A.A.; Laarse, A. van der; Krauss, X.H.; Blokland, J.A.k.; Manger Cats, V.; Voorthuisen, A.E. van; Bruschke, A.V.G.

    1991-01-01

    The cardiovascular applications of MRI in coronary artery disease have considerably increased in recent years. Although many applications overlap those of other more cost-effective techniques, such as echocardiography, radionuclide angiography, and CT, MRI offers unique features not shared by the conventional techniques. Technical advantages are the excellent spatial resolution, the characterization of myocardial tissue, and the potential for three-dimensional imaging. This allows the accurate assessment of left ventricular mass and volume, the differentiation of infarcted tissue from normal myocardial tissue, and the determination of systolic wall thickening and regional wall motion abnormalities. Also inducible myocardial ischemia using pharmacological stress (dipyramidole or dobutamine) may be assessed by magnetic resonance imaging. Future technical developments include real-time imaging and noninvasive visualization of the coronary arteries. These advantages will have a major impact on the application of MRI in coronary artery disease, potentially unsurpassed by other techniques and certainly justifying the expenses. Consequently, the clinical use of MRI for the detection of coronary artery disease largely depends on the progress of technical developments. (author). 134 refs.; 10 figs.; 2 tabs

  5. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  6. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  7. Early Cardiac Involvement Affects Left Ventricular Longitudinal Function in Females Carrying α-Galactosidase A Mutation: Role of Hybrid Positron Emission Tomography and Magnetic Resonance Imaging and Speckle-Tracking Echocardiography.

    Science.gov (United States)

    Spinelli, Letizia; Imbriaco, Massimo; Nappi, Carmela; Nicolai, Emanuele; Giugliano, Giuseppe; Ponsiglione, Andrea; Diomiaiuti, Tommaso Claudio; Riccio, Eleonora; Duro, Giovanni; Pisani, Antonio; Trimarco, Bruno; Cuocolo, Alberto

    2018-04-01

    Hybrid 18 F-fluorodeoxyglucose (FDG) positron emission tomography and magnetic resonance imaging may differentiate mature fibrosis or scar from fibrosis associated to active inflammation in patients with Anderson-Fabry disease, even in nonhypertrophic stage. This study was designed to compare the results of positron emission tomography and magnetic resonance cardiac imaging with those of speckle-tracking echocardiography in heterozygous Anderson-Fabry disease females. Twenty-four heterozygous females carrying α-galactosidase A mutation and without left ventricular hypertrophy underwent cardiac positron emission tomography and magnetic resonance using 18 F-FDG for glucose uptake and 2-dimensional strain echocardiography. 18 F-FDG myocardial uptake was quantified by measuring the coefficient of variation (COV) of the standardized uptake value using a 17-segment model. Focal 18 F-FDG uptake with COV >0.17 was detected in 13 patients, including 2 patients with late gadolinium enhancement at magnetic resonance. COV was 0.30±0.14 in patients with focal 18 F-FDG uptake and 0.12±0.03 in those without ( P 0.17 compared with those with COV ≤0.17 (-18.5±2.7% versus -22.2±1.8%; P =0.024). For predicting COV >0.17, a global longitudinal strain >-19.8% had 77% sensitivity and 91% specificity and a value >2 dysfunctional segments 92% sensitivity and 100% specificity. In females carrying α-galactosidase A mutation, focal 18 F-FDG uptake represents an early sign of disease-related myocardial damage and is associated with impaired left ventricular longitudinal function. These findings support the hypothesis that inflammation plays an important role in glycosphingolipids storage disorders. © 2018 American Heart Association, Inc.

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or thyroid problems. Any of these conditions may influence the decision on whether contrast material will be ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the technologist or scheduler before the exam. ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... necessary in trauma situations. Although there is no reason to believe that magnetic resonance imaging harms the ...

  19. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  20. Magnetic Resonance Imaging. Chapter 15

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M. O. [The Institute of Cancer Research and The Royal Marsden Hospital, London (United Kingdom)

    2014-09-15

    In Chapter 14, the principles of nuclear magnetic resonance were presented, along with an introduction to image forming processes. In this chapter, magnetic resonance imaging (MRI) will be reviewed, beginning with the hardware needed and its impact on image quality. The acquisition processes and image reconstruction will be discussed, as well as the artefacts that are possible, with discussion of the important area of safety and bioeffects completing the chapter.

  1. The nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Goyer, Ph.

    1997-01-01

    The spectroscopy of nuclear magnetic resonance constitutes a major analytical technique in biological and organic analysis. This technique appears now in the programme of preparatory classes and its teaching is developed in the second year of DEUG. The following article reviews on the nuclear magnetic resonance and on the possibilities it offers to bring to the fore the physico-chemical properties of molecules. (N.C.)

  2. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  3. Nuclear magnetic resonance diagnostic apparatus

    International Nuclear Information System (INIS)

    Sugimoto, H.

    1985-01-01

    Nuclear magnetic resonance diagnostic apparatus including a coil for generating a gradient field in a plane perpendicular to a static magnetic field, means for controlling the operation of the coil to rotationally shift in angular steps the gradient direction of the gradient field at an angle pitch of some multiple of the unit index angle through a plurality of rotations to assume all the shift positions of the gradient direction, a rough image reconstructor for reconstructing a rough tomographic image on the basis of nuclear magnetic resonance signals acquired during a rotation of the second gradient magnetic field, a rough image display for depicting the rough tomographic image, a final image reconstructor for reconstructing a final tomographic image on the basis of all nuclear magnetic resonance signals corresponding to all of the expected rotation shift positions acquired during a plurality of rotations and a final image display for depicting the final tomographic image

  4. Nuclear magnetic resonance and earth magnetic field

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    Nuclear magnetic resonance concerns nuclei whose spin is different from 0. These nuclei exposed to a magnetic field is comparable to a peg top spinning around its axis while being moved by a precession movement called Larmor precession. This article presents an experiment whose aim is to reveal nuclear magnetism of nuclei by observing Larmor precession phenomena due to the earth magnetic field. The earth magnetic field being too weak, it is necessary to increase the magnetization of the sample during a polarization phase. First the sample is submitted to a magnetic field B perpendicular to the earth magnetic field B 0 , then B is cut off and the nuclei move back to their equilibrium position by executing a precession movement due to B 0 field. (A.C.)

  5. Magnetic Resonance Imaging

    Science.gov (United States)

    ... Permanent cosmetics or tattoos Dentures/teeth with magnetic keepers Other implants that involve magnets Medication patch (i. ... or longer. You’ll be told ahead of time just how long your scan is expected to ...

  6. Noble gas magnetic resonator

    Science.gov (United States)

    Walker, Thad Gilbert; Lancor, Brian Robert; Wyllie, Robert

    2014-04-15

    Precise measurements of a precessional rate of noble gas in a magnetic field is obtained by constraining the time averaged direction of the spins of a stimulating alkali gas to lie in a plane transverse to the magnetic field. In this way, the magnetic field of the alkali gas does not provide a net contribution to the precessional rate of the noble gas.

  7. Fourier transform nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Geick, R.

    1981-01-01

    This review starts with the basic principles of resonance phenomena in physical systems. Especially, the connection is shown between the properties of these systems and Fourier transforms. Next, we discuss the principles of nuclear magnetic resonance. Starting from the general properties of physical systems showing resonance phenomena and from the special properties of nuclear spin systems, the main part of this paper reviews pulse and Fourier methods in nuclear magnetic resonance. Among pulse methods, an introduction will be given to spin echoes, and, apart from the principle of Fourier transform nuclear magnetic resonance, an introduction to the technical problems of this method, e.g. resolution in the frequency domain, aliasing, phase and intensity errors, stationary state of the spin systems for repetitive measurements, proton decoupling, and application of Fourier methods to systems in a nonequilibrium state. The last section is devoted to special applications of Fourier methods and recent developments, e.g. measurement of relaxation times, solvent peak suppression, 'rapid scan'-method, methods for suppressing the effects of dipolar coupling in solids, two-dimensional Fourier transform nuclear magnetic resonance, and spin mapping or zeugmatography. (author)

  8. Resonant longitudinal Zitterbewegung in zigzag graphene nanoribbons

    KAUST Repository

    Ghosh, S.; Schwingenschlö gl, Udo; Manchon, Aurelien

    2015-01-01

    The Zitterbewegung of a wave packet in a zigzag graphene nanoribbon is theoretically investigated. The coupling between edge states and bulk states results in intriguing properties. Apart from the oscillation in position perpendicular to the direction of motion, we also observe an oscillation along the direction of propagation which is not present in semiconductor nanowires or infinite graphene sheets. We also observe a resonance of its amplitude with respect to the central momentum of the wave packet. We show here that this longitudinal Zitterbewegung is caused by the interplay between bulk and edge states, which is a unique property of a zigzag nanoribbon.

  9. Resonant longitudinal Zitterbewegung in zigzag graphene nanoribbons

    KAUST Repository

    Ghosh, S.

    2015-01-08

    The Zitterbewegung of a wave packet in a zigzag graphene nanoribbon is theoretically investigated. The coupling between edge states and bulk states results in intriguing properties. Apart from the oscillation in position perpendicular to the direction of motion, we also observe an oscillation along the direction of propagation which is not present in semiconductor nanowires or infinite graphene sheets. We also observe a resonance of its amplitude with respect to the central momentum of the wave packet. We show here that this longitudinal Zitterbewegung is caused by the interplay between bulk and edge states, which is a unique property of a zigzag nanoribbon.

  10. Magnetic resonance and porous materials

    International Nuclear Information System (INIS)

    McDonald, P.; Strange, J.

    1998-01-01

    Mention the words magnetic resonance to your medical advisor and he or she will immediately think of a multi-million pound scanner that peers deep into the brain. A chemist, on the other hand, will imagine a machine that costs several hundred thousand pounds and produces high-resolution spectra for chemical analysis. Food technologists will probably think of a bench-top instrument for determining moisture content, while an oil prospector will envisage a device that can be operated several kilometres down an oil well. To a physicist the term is more likely to conjure up a mental picture of nuclear spins precessing in a magnetic field. These examples illustrate the diverse aspects of a phenomenon discovered by physicists over 50 years ago. Electron spin resonance was first discovered by Russian scientists, and nuclear magnetic resonance was discovered in the US shortly afterwards by Ed Purcell at Harvard University and Felix Bloch at Stanford University. Today, nuclear magnetic resonance (NMR) is the most widely used technique. Modern NMR machines are making it possible to probe microstructure and molecular movement in materials as diverse as polymers, cements, rocks, soil and foods. NMR allows the distribution of different components in a material to be determined with a resolution approaching 1μm, although the signal can be sensitive to even smaller lengthscales. In this article the authors describe how physicists are still developing magnetic resonance to exploit a range of new applications. (UK)

  11. GHz nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  12. Principles of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mlynarik, V.; Tkac, I.; Srbecky, M.

    1995-01-01

    The aim of this review is to describe and explain the basic principles of magnetic resonance imaging. The first part of the text is devoted to the phenomenon of magnetic resonance (the interaction of RF magnetic field with the set of magnetic moments in the homogeneous magnetic field) and to relaxation processes. Then, the creation of MR image is described (slice selection, phase and frequency encoding of spatial information). The basic and the most frequently used techniques are explained (spin echo, gradient echo). The way the repetition and echo times influence the image quality and contrast (T1 or T2 weighing) is described. The part with the technical description of the MR equipment is included in the review. The MR imagination examination are compared with X-ray computer tomography technique

  13. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    Energy Technology Data Exchange (ETDEWEB)

    Vasilevskaya, Tatiana M., E-mail: t_vasilevs@mail.ru [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation); Sementsov, Dmitriy I.; Shutyi, Anatoliy M. [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation)

    2012-09-15

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: Black-Right-Pointing-Pointer An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. Black-Right-Pointing-Pointer Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. Black-Right-Pointing-Pointer Both regular and chaotic precession modes are realized within bifurcation resonance range. Black-Right-Pointing-Pointer Appearance of dynamic bistability is typical for bifurcation resonance.

  14. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    International Nuclear Information System (INIS)

    Vasilevskaya, Tatiana M.; Sementsov, Dmitriy I.; Shutyi, Anatoliy M.

    2012-01-01

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: ► An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. ► Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. ► Both regular and chaotic precession modes are realized within bifurcation resonance range. ► Appearance of dynamic bistability is typical for bifurcation resonance.

  15. Recommendations concerning magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    1986-01-01

    In medicine the technique of nuclear magnetic resonance (NMR) is applied in the form of in vivo nuclear magnetic resonance spectroscopy (MRS). In vivo MRS can be carried out non-invasively. The committee of the Dutch Health Council briefly discusses the qualities and potentialities of the nuclei that will probably be used in future clinical spectroscopy: 31 P, 13 C, 1 H (and possibly 19 F and 23 Na). The committee discusses several possibilities of combining imaging and spectroscopy. The imaging of nuclei other than protons is also possible with MRS. Potential applications are considered in oncology, cardiology, neurology and hepatology. (Auth.)

  16. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...

  17. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance Imaging Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  5. Proton Magnetic Resonance Spectroscopic Imaging in Newly Diagnosed Glioblastoma: Predictive Value for the Site of Postradiotherapy Relapse in a Prospective Longitudinal Study

    International Nuclear Information System (INIS)

    Laprie, Anne; Catalaa, Isabelle; Cassol, Emmanuelle; McKnight, Tracy R.; Berchery, Delphine; Marre, Delphine; Bachaud, Jean-Marc; Berry, Isabelle; Moyal, Elizabeth Cohen-Jonathan

    2008-01-01

    Purpose: To investigate the association between magnetic resonance spectroscopic imaging (MRSI)-defined, metabolically abnormal tumor regions and subsequent sites of relapse in data from patients treated with radiotherapy (RT) in a prospective clinical trial. Methods and Materials: Twenty-three examinations were performed prospectively for 9 patients with newly diagnosed glioblastoma multiforme studied in a Phase I trial combining Tipifarnib and RT. The patients underwent magnetic resonance imaging (MRI) and MRSI before treatment and every 2 months until relapse. The MRSI data were categorized by the choline (Cho)/N-acetyl-aspartate (NAA) ratio (CNR) as a measure of spectroscopic abnormality. CNRs corresponding to T1 and T2 MRI for 1,207 voxels were evaluated before RT and at recurrence. Results: Before treatment, areas of CNR2 (CNR ≥2) represented 25% of the contrast-enhancing (T1CE) regions and 10% of abnormal T2 regions outside T1CE (HyperT2). The presence of CNR2 was often an early indicator of the site of relapse after therapy. In fact, 75% of the voxels within the T1CE+CNR2 before therapy continued to exhibit CNR2 at relapse, compared with 22% of the voxels within the T1CE with normal CNR (p < 0.05). The location of new contrast enhancement with CNR2 corresponded in 80% of the initial HyperT2+CNR2 vs. 20.7% of the HyperT2 voxels with normal CNR (p < 0.05). Conclusion: Metabolically active regions represented a small percentage of pretreatment MRI abnormalities and were predictive for the site of post-RT relapse. The incorporation of MRSI data in the definition of RT target volumes for selective boosting may be a promising avenue leading to increased local control of glioblastomas

  6. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What ...

  7. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    1997-01-01

    Since 1965, Advances in Magnetic and Optical Resonance has provided researchers with timely expositions of fundamental new developments in the theory of, experimentation with, and application of magnetic and optical resonance.

  8. Magnetic resonance for wireless power transfer

    OpenAIRE

    Hui, SYR

    2016-01-01

    Magnetic resonance has been a cornerstone of nonradiative wireless power transfer (WPT) since the late 19th century. However, some researchers have the misconception that magnetic resonance for WPT was developed recently. This article traces some early work of Tesla and other researchers related to the use of magnetic resonance in WPT. Included are some examples of magnetic resonance-based WPT projects conducted by researchers in the biomedical and power electronics communities over the last ...

  9. SQUID-detected magnetic resonance imaging in microtesla magnetic fields

    International Nuclear Information System (INIS)

    McDermott, Robert; Kelso, Nathan; Lee, SeungKyun; Moessle, Michael; Mueck, Michael; Myers, Whittier; Haken, Bernard ten; Seton, H.C.; Trabesinger, Andreas H.; Pines, Alex; Clarke, John

    2003-01-01

    We describe studies of nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) of liquid samples at room temperature in microtesla magnetic fields. The nuclear spins are prepolarized in a strong transient field. The magnetic signals generated by the precessing spins, which range in frequency from tens of Hz to several kHz, are detected by a low-transition temperature dc SQUID (Superconducting QUantum Interference Device) coupled to an untuned, superconducting flux transformer configured as an axial gradiometer. The combination of prepolarization and frequency-independent detector sensitivity results in a high signal-to-noise ratio and high spectral resolution (∼1 Hz) even in grossly inhomogeneous magnetic fields. In the NMR experiments, the high spectral resolution enables us to detect the 10-Hz splitting of the spectrum of protons due to their scalar coupling to a 31P nucleus. Furthermore, the broadband detection scheme combined with a non-resonant field-reversal spin echo allows the simultaneous observation of signals from protons and 31P nuclei, even though their NMR resonance frequencies differ by a factor of 2.5. We extend our methodology to MRI in microtesla fields, where the high spectral resolution translates into high spatial resolution. We demonstrate two-dimensional images of a mineral oil phantom and slices of peppers, with a spatial resolution of about 1 mm. We also image an intact pepper using slice selection, again with 1-mm resolution. In further experiments we demonstrate T1-contrast imaging of a water phantom, some parts of which were doped with a paramagnetic salt to reduce the longitudinal relaxation time T1. Possible applications of this MRI technique include screening for tumors and integration with existing multichannel SQUID systems for brain imaging

  10. Limits to magnetic resonance microscopy

    International Nuclear Information System (INIS)

    Glover, Paul; Mansfield, Peter

    2002-01-01

    The last quarter of the twentieth century saw the development of magnetic resonance imaging (MRI) grow from a laboratory demonstration to a multi-billion dollar worldwide industry. There is a clinical body scanner in almost every hospital of the developed nations. The field of magnetic resonance microscopy (MRM), after mostly being abandoned by researchers in the first decade of MRI, has become an established branch of the science. This paper reviews the development of MRM over the last decade with an emphasis on the current state of the art. The fundamental principles of imaging and signal detection are examined to determine the physical principles which limit the available resolution. The limits are discussed with reference to liquid, solid and gas phase microscopy. In each area, the novel approaches employed by researchers to push back the limits of resolution are discussed. Although the limits to resolution are well known, the developments and applications of MRM have not reached their limit. (author)

  11. Magnetic resonance and its applications

    CERN Document Server

    Chizhik, Vladimir I; Donets, Alexey V; Frolov, Vyacheslav V; Komolkin, Andrei V; Shelyapina, Marina G

    2014-01-01

    The book provides a basic understanding of the underlying theory, fundamentals and applications of magnetic resonance The book implies a few levels of the consideration (from simple to complex) of phenomena, that can be useful for different groups of readers The introductory chapter provides the necessary underpinning knowledge for newcomers to the methods The exposition of theoretical materials goes from initial to final formulas through detailed intermediate expressions.

  12. Longitudinal Assessment of Renal Perfusion and Oxygenation in Transplant Donor-Recipient Pairs Using Arterial Spin Labeling and Blood Oxygen Level-Dependent Magnetic Resonance Imaging.

    Science.gov (United States)

    Niles, David J; Artz, Nathan S; Djamali, Arjang; Sadowski, Elizabeth A; Grist, Thomas M; Fain, Sean B

    2016-02-01

    The aims of this study were to assess renal function in kidney transplant recipients and their respective donors over 2 years using arterial spin labeling (ASL) and blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI) and to prospectively evaluate the effect of losartan on functional MRI measures in recipients. The study included 15 matched pairs of renal transplant donors and recipients. Arterial spin labeling and BOLD MRI of the kidneys were performed on donors before transplant surgery (baseline) and on both donors and recipients at 3 months, 1 year, and 2 years after transplant. After 3 months, 7 of the 15 recipients were prescribed 25 to 50 mg/d losartan for the remainder of the study. A linear mixed-effects model was used to evaluate perfusion, R2*, estimated glomerular filtration rate, and fractional excretion of sodium for changes across time or associated with losartan treatment. In donors, cortical perfusion in the remaining kidney decreased by 50 ± 19 mL/min per 100 g (11.8%) between baseline and 2 years (P donors and to 14.6 ± 4.3 mL/min per 1.73 m (33.3%; P donors, and they indicate a potentially beneficial effect of losartan in recipients.

  13. Longitudinal Changes in Segmental Aortic Stiffness Determined by Cardiac Magnetic Resonance in Children and Young Adults With Connective Tissue Disorders (the Marfan, Loeys-Dietz, and Ehlers-Danlos Syndromes, and Nonspecific Connective Tissue Disorders).

    Science.gov (United States)

    Merlocco, Anthony; Lacro, Ronald V; Gauvreau, Kimberlee; Rabideau, Nicole; Singh, Michael N; Prakash, Ashwin

    2017-10-01

    Aortic stiffness measured by cardiac magnetic resonance (CMR) in connective tissue disorder (CTD) patients has been previously shown to be abnormal and to be associated with adverse aortic outcomes. The rate of increase in aortic stiffness with normal aging has been previously described. However, longitudinal changes in aortic stiffness have not been characterized in CTD patients. We examined longitudinal changes in CMR-derived aortic stiffness in children and young adults with CTDs. A retrospective analysis of 50 children and young adults (median age, 20 years; range, 0.2 to 49; 40% age, whereas the β stiffness index increased at all aortic segments. The average rates of decline in distensibility (x10 -3  mm Hg -1 per 10-year increase in age) were 0.7, 1.3, and 1 at the AoR, ascending aorta, and descending aorta, respectively. The rates of decline in distensibility were not associated with the rates of AoR dilation or surgical AoR replacement. In conclusion, on serial CMR measurements in children and young adults with CTDs, aortic stiffness progressively increased with age, with rates of change only slightly higher than those previously reported in healthy adults. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Longitudinal and transverse electric field measurements in resonant cavities

    International Nuclear Information System (INIS)

    Tong Dechun; Chen Linfeng; Zheng Xiaoyue

    1994-01-01

    The paper presents a measuring technique for the electric field distribution of high order modes in resonant cavities. A perturbing bead-like cage made with metallic wires are developed for S-band field measurements, which can be used to detect a small electric field component in the presence of other strong electric or magnetic field components (That means high sensitivity and high directivity). In order to avoid orientation error for the cage with very high directivity, two parallel threads were used for supporting the perturbing cage. A simple mechanical set-up is described. The cage can be driven into the cavity on-axis or off-axis in any azimuth for the longitudinal and transverse electric field measurements

  15. A Longitudinal Magnetic Resonance Imaging Study of the Apparent Diffusion Coefficient Values in Corpus Callosum during the First Year after Traumatic Brain Injury

    Science.gov (United States)

    Håberg, Asta Kristine; Skandsen, Toril; Finnanger, Torun Gangaune; Vik, Anne

    2014-01-01

    Abstract The objective of this study was to explore the evolution of apparent diffusion coefficient (ADC) values in magnetic resonance imaging (MRI) in normal-appearing tissue of the corpus callosum during the 1st year after traumatic brain injury (TBI), and relate findings to outcome. Fifty-seven patients (mean age 34 [range 11–63] years) with moderate to severe TBI were examined with diffusion weighted MRI at three time points (median 7 days, 3 and 12 months), and a sex- and age-matched control group of 47 healthy individuals, were examined once. The corpus callosum was subdivided and the mean ADC values computed blinded in 10 regions of interests without any visible lesions in the ADC map. Outcome measures were Glasgow Outcome Scale Extended (GOSE) and neuropsychological domain scores at 12 months. We found a gradual increase of the mean ADC values during the 12 month follow-up, most evident in the posterior truncus (r=0.19, pGOSE score ≤6) showed evidence of increased mean ADC values in the genu and posterior truncus at 12 months. Mean ADC values in posterior parts of the corpus callosum at 3 months predicted the sensory-motor function domain score (p=0.010–0.028). During the 1st year after moderate and severe TBI, we demonstrated a slowly evolving disruption of the microstructure in normal appearing corpus callosum in the ADC map, most evident in the posterior truncus. The mean ADC values were associated with both outcome and ability to perform speeded, complex sensory-motor action. PMID:23837731

  16. Longitudinal changes in the brain in mild cognitive impairment: a magnetic resonance imaging study using the visual rating method and tensor-based morphometry.

    Science.gov (United States)

    Tuokkola, Terhi; Koikkalainen, Juha; Parkkola, Riitta; Karrasch, Mira; Lötjönen, Jyrki; Rinne, Juha O

    2017-01-01

    Background Brain atrophy is associated with mild cognitive impairment (MCI), and by using volumetric and visual analyzing methods, it is possible to differentiate between individuals with progressive MCI (MCIp) and stable MCI (MCIs). Automated analysis methods detect degenerative changes in the brain earlier and more reliably than visual methods. Purpose To detect and evaluate structural brain changes between and within the MCIs, MCIp, and control groups during a two-year follow-up period. Material and Methods Brain magnetic resonance imaging (MRI) scans of 11 participants with MCIs, 18 participants with MCIp, and 84 controls were analyzed by the visual rating method (VRM) and tensor-based morphometry (TBM). Results At baseline, both VRM and TBM differentiated the whole MCI group (combined MCIs and MCIp) and the MCIp group from the control group, but they did not differentiate the MCIs group from the control group. At follow-up, both methods differentiated the MCIp group from the control group, but minor differences between the MCIs and control groups were only seen by TBM. Neuropsychological tests did not find differences between the MCIs and control groups at follow-up. Neither method revealed relevant signs of brain atrophy progression within or between MCI subgroups during the follow-up time. Conclusion Both methods are equally good in the evaluation of structural brain changes in MCI if the groups are sufficiently large and the disease progresses to AD. Only TBM disclosed minor atrophic changes in the MCIs group compared to controls at follow-up. The results need to be confirmed with a large patient group and longer follow-up time.

  17. The nuclear magnetic resonance well logging

    International Nuclear Information System (INIS)

    Zhang Yumin; Shen Huitang

    2003-01-01

    In this paper, the characteristic of the nuclear magnetic resonance logging is described at first. Then its development and its principle is presented. Compared with the nuclear magnetic resonance spectrometer, the magnet techniques is the first question that we must solve in the manufacture of the NMR well logging

  18. Magnetic resonance imaging of intervertebral disc degeneration

    International Nuclear Information System (INIS)

    Maeda, Hiroshi; Noguchi, Masao; Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi.

    1993-01-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.)

  19. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  20. Magnetic resonance imaging at Rikshospitalet

    International Nuclear Information System (INIS)

    Smith, H.J.

    1990-01-01

    During the first 18 months of operations of the nuclear magnetic resonance (NMR) unit at Rikshospitalet, 1453 NMR examinations have been performed on 1431 patients. 64% of the time has been devoted to examinations of the central nervous system and spine in children and adults, 9% of the time has been used on non-neuroradiology pediatric patients, while the rest of the time has been spent equally on ear, nose and throat, thoracic (including cardiac) and abdominal examinations in adult patients. The indications for doing NMR at Rikshospitalet are listed and discussed, and it is concluded that NMR has proved to be useful at several conditions in most organ systems. 15 refs

  1. Magnetic resonance imaging in psychiatry

    International Nuclear Information System (INIS)

    Mann, K.

    1993-01-01

    Diagnosis and research in psychiatry are increasingly availing themselves of magnetic resonance imaging (MRI). In comparison to computed tomography (CT), this offers the combined benefits of no exposure to radiation, high resolution, artefact-free display of structures near bone, and a sharp contrast between the grey and white brain matter, with freedom to select the section. With the exception of very anxious patients, MRI will gradually replace CT scans for a wide range of differential diagnostic investigations. Its superiority in systematic studies of psychiatric patients with discrete cerebral parenchyma lesions is already considered proven. This is illustrated on the basis of research into schizophrenia and alcoholism. (orig.) [de

  2. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  3. Resonant and nonresonant magnetic scattering (invited)

    International Nuclear Information System (INIS)

    McWhan, D.B.; Hastings, J.B.; Kao, C.; Siddons, D.P.

    1992-01-01

    The tunability and the polarization of synchrotron radiation open up new possibilities for the study of magnetism. Studies on magnetic materials performed at the National Synchrotron Light Source are reviewed, and they fall into four areas: structure, evolution of magnetic order, separation of L and S, and resonance effects. In the vicinity of atomic absorption edges, the Faraday effect, magnetic circular dichroism, and resonant magnetic scattering are all related resonance effects which measure the spin-polarized density of states. The production and analysis of polarized beams are discussed in the context of the study of magnetism with synchrotron radiation

  4. SU-F-I-68: Longitudinal Neurochemical Changes On Rat Prefrontal Cortex of Single Prolonged Stress Model by Using Proton Magnetic Resonance Spectroscopy at 9.4T

    International Nuclear Information System (INIS)

    Lim, S-I; Yoo, C-H; Song, K-H; Choe, B-Y; Woo, D-C

    2016-01-01

    Purpose: Single prolonged stress (SPS) is an animal model of posttraumatic stress disorder (PTSD). However, it has not been known how PTSD develops from the first exposure to traumatic events and neurochemical differences between acute/single stress and PTSD-triggering stress. Therefore, the object of this study is to determine time-dependent neurochemical changes in prefrontal cortex (PFC) of rats using in vivo proton magnetic resonance spectroscopy (1H-MRS). Methods: Male Sprague-Dawley rats (n=14; body weight=200–220g) were used. The SPS protocol was used in this study. Rats were restrained for 2h and then immediately forced to swim for 20min in water (20–24 Celsius). After a 15-min recuperation period, rats were exposed to ether (using a desiccator) until general anesthesia occurred (<5min). In vivo proton MRS was performed 30min before the SPS (Base), approximately 10min after the SPS (D+0), 3 (D+3) and 7 (D+7) days after SPS to investigate time-dependent changes on metabolites levels in the PFC. Acquisition of in vivo MRS spectra and MRI was conducted at the four time points using 9.4 T Agilent Scanner. Concentration of metabolites was quantified by LCModel. Results: Statistical significance was analyzed using one-way ANOVA with post hoc Tukey HSD tests to assess the metabolite changes in the PFC. The SPS resulted in significant stress-induced differences for 7 days in glutamine (F(3,52)=6.750, P=0.001), choline-containing compounds (F(3,52)=16.442, P=0.000), glutamine/glutamate concentrations (F(3,52)=7.352, P=0.000). Conclusion: PTSD in human is associated with decreased neuronal activity in the PFC. In this study, SPS altered total choline, glutamine levels but not NAA levels in the PFC of the rats. Therefore, for the three stressors and quiescent period of seven days, SPS attenuated excitatory tone and membrane turnover but did not affect neural integrity in the PFC.

  5. Usefulness of magnetic resonance findings of the hypothalamic-pituitary region in the management of short children with growth hormone deficiency: evidence from a longitudinal study.

    Science.gov (United States)

    Kalina, Maria A; Kalina-Faska, Barbara; Gruszczyńska, Katarzyna; Baron, Jan; Małecka-Tendera, Ewa

    2012-01-01

    The purpose of this study is to assess the relationship between magnetic resonance images (MRI) of the hypothalamic-pituitary (H-P) region and response to recombinant human growth hormone (rhGH) treatment in short children with growth hormone deficiency, basing on changes of auxologic parameters, as well as to answer the question if MRI may serve for selecting and monitoring the rhGH responders. The study group comprised 85 children treated with rhGH, aged 7.3-18.7 years, followed for the mean period of 3.2 years (range, 2.1-9.5 years). Auxologic parameters (height deficit hSDS, deviation from the mid-parental height hSDS-mpSDS, bone delay index bone age/chronological age ratio (BA/CA)) were assessed before, during and at the end of rhGH treatment; growth velocity was calculated before and during rhGH therapy. Parameters were correlated with the MRI of the H-P region. Structural anomalies of the H-P region were found in 22 (25.9%) children: empty sella syndrome (ESS) in 12 (14.1%) patients, ectopic posterior pituitary (EPP) in ten (11.8%). Patients' height deficit and their deviation from parental height before rhGH therapy was significantly greater in the EPP group (median hSDS = -3.8; hSDS-mpSDS = -2.5), bone age delay was the greatest in the ESS group (median BA/CA = 0.69), after therapy - in the EPP group (median BA/CA = 0.82). Growth velocity improved in the first year of the rhGH therapy in all groups; however, the most significant acceleration was observed in the EPP group (median delta hSDS = 0.9), then stabilised and was comparable in all groups. MRI may be helpful in predicting response to the rhGH treatment, providing midline abnormalities are taken into account.

  6. SU-F-I-68: Longitudinal Neurochemical Changes On Rat Prefrontal Cortex of Single Prolonged Stress Model by Using Proton Magnetic Resonance Spectroscopy at 9.4T

    Energy Technology Data Exchange (ETDEWEB)

    Lim, S-I; Yoo, C-H [Department of Biomedical Engineering, and Research Institute of Biomedical Engineering, The Catholic University of Korea College of Medicine, Seoul, Seoul (Korea, Republic of); Asan Institute for Life Sciences, Asan Medical Center, Seoul, Seoul (Korea, Republic of); Song, K-H; Choe, B-Y [Department of Biomedical Engineering, and Research Institute of Biomedical Engineering, The Catholic University of Korea College of Medicine, Seoul, Seoul (Korea, Republic of); Woo, D-C [Asan Institute for Life Sciences, Asan Medical Center, Seoul, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: Single prolonged stress (SPS) is an animal model of posttraumatic stress disorder (PTSD). However, it has not been known how PTSD develops from the first exposure to traumatic events and neurochemical differences between acute/single stress and PTSD-triggering stress. Therefore, the object of this study is to determine time-dependent neurochemical changes in prefrontal cortex (PFC) of rats using in vivo proton magnetic resonance spectroscopy (1H-MRS). Methods: Male Sprague-Dawley rats (n=14; body weight=200–220g) were used. The SPS protocol was used in this study. Rats were restrained for 2h and then immediately forced to swim for 20min in water (20–24 Celsius). After a 15-min recuperation period, rats were exposed to ether (using a desiccator) until general anesthesia occurred (<5min). In vivo proton MRS was performed 30min before the SPS (Base), approximately 10min after the SPS (D+0), 3 (D+3) and 7 (D+7) days after SPS to investigate time-dependent changes on metabolites levels in the PFC. Acquisition of in vivo MRS spectra and MRI was conducted at the four time points using 9.4 T Agilent Scanner. Concentration of metabolites was quantified by LCModel. Results: Statistical significance was analyzed using one-way ANOVA with post hoc Tukey HSD tests to assess the metabolite changes in the PFC. The SPS resulted in significant stress-induced differences for 7 days in glutamine (F(3,52)=6.750, P=0.001), choline-containing compounds (F(3,52)=16.442, P=0.000), glutamine/glutamate concentrations (F(3,52)=7.352, P=0.000). Conclusion: PTSD in human is associated with decreased neuronal activity in the PFC. In this study, SPS altered total choline, glutamine levels but not NAA levels in the PFC of the rats. Therefore, for the three stressors and quiescent period of seven days, SPS attenuated excitatory tone and membrane turnover but did not affect neural integrity in the PFC.

  7. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  8. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki; Fujishiro, Kenichiro.

    1989-01-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author)

  9. Magnetic resonance imaging of Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Eiichiro [National Hospital of Nagoya (Japan); Makino, Naoki; Fujishiro, Kenichiro

    1989-06-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author).

  10. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...... in the methodology and quality of the MRS migraine studies over time, some results were consistent and reproducible. 31P-MRS studies suggested reduced availability of neuronal energy and implied a mitochondrial dysfunction in the migraine brain. 1H-MRS studies reported interictal abnormalities in the excitatory...... and inhibitory neurotransmitters, glutamate and g-aminobutyric acid (GABA), suggesting persistent altered excitability in migraine patients. N-Acetylaspartate levels were decreased in migraine, probably due to a mitochondrial dysfunction and abnormal energy metabolism. The reported abnormalities may increase...

  11. Magnetic resonance imaging of chemistry.

    Science.gov (United States)

    Britton, Melanie M

    2010-11-01

    Magnetic resonance imaging (MRI) has long been recognized as one of the most important tools in medical diagnosis and research. However, MRI is also well placed to image chemical reactions and processes, determine the concentration of chemical species, and look at how chemistry couples with environmental factors, such as flow and heterogeneous media. This tutorial review will explain how magnetic resonance imaging works, reviewing its application in chemistry and its ability to directly visualise chemical processes. It will give information on what resolution and contrast are possible, and what chemical and physical parameters can be measured. It will provide examples of the use of MRI to study chemical systems, its application in chemical engineering and the identification of contrast agents for non-clinical applications. A number of studies are presented including investigation of chemical conversion and selectivity in fixed-bed reactors, temperature probes for catalyst pellets, ion mobility during tablet dissolution, solvent dynamics and ion transport in Nafion polymers and the formation of chemical waves and patterns.

  12. Leucoencephalopathy with brainstem and spinal cord involvement and high lactate: quantitative magnetic resonance imaging

    NARCIS (Netherlands)

    Steenweg, M.E.; Pouwels, P.J.W.; Wolf, N.I.; van Wieringen, W.N.; Barkhof, F.; van der Knaap, M.S.

    2011-01-01

    Leucoencephalopathy with brainstem and spinal cord involvement and elevated lactate is a white matter disorder caused by DARS2 mutations. The pathology is unknown. We observed striking discrepancies between improvement on longitudinal conventional magnetic resonance images and clinical deterioration

  13. Magnetic field of longitudinal gradient bend

    Science.gov (United States)

    Aiba, Masamitsu; Böge, Michael; Ehrlichman, Michael; Streun, Andreas

    2018-06-01

    The longitudinal gradient bend is an effective method for reducing the natural emittance in light sources. It is, however, not a common element. We have analyzed its magnetic field and derived a set of formulae. Based on the derivation, we discuss how to model the longitudinal gradient bend in accelerator codes that are used for designing electron storage rings. Strengths of multipole components can also be evaluated from the formulae, and we investigate the impact of higher order multipole components in a very low emittance lattice.

  14. Advances in mechanical detection of magnetic resonance

    International Nuclear Information System (INIS)

    Kuehn, Seppe; Hickman, Steven A.; Marohn, John A.

    2008-01-01

    The invention and initial demonstration of magnetic resonance force microscopy (MRFM) in the early 1990s launched a renaissance of mechanical approaches to detecting magnetic resonance. This article reviews progress made in MRFM in the last decade, including the demonstration of scanned probe detection of magnetic resonance (electron spin resonance, ferromagnetic resonance, and nuclear magnetic resonance) and the mechanical detection of electron spin resonance from a single spin. Force and force-gradient approaches to mechanical detection are reviewed and recent related work using attonewton sensitivity cantilevers to probe minute fluctuating electric fields near surfaces is discussed. Given recent progress, pushing MRFM to single proton sensitivity remains an exciting possibility. We will survey some practical and fundamental issues that must be resolved to meet this challenge.

  15. Magnetic resonance imaging: hazard, risk and safety

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Suri, S.; Singh, P.

    2001-01-01

    The hazard and risk associated with magnetic resonance imaging is a matter of concern. In 1982, the Food and Drug Administration (FDA), USA issued guidelines to Hospital's Investigational Review Board (IRBs) in 'Guidelines for Evaluating Electromagnetic Exposure Risks for Trials of Clinical Nuclear Magnetic Resonance (NMR)'. In 1997, the Berufsgenossenschaft (BG), professional association for precision engineering and electronics of Germany, in their preliminary proposal for safety limits extended their concerns on static magnetic field. Owing to both time varying and static magnetic fields applied in Magnetic Resonance Imaging (MRI) this became of immediate concern to user community to assess the potential hazard and risk associated with the NMR system

  16. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Nakamura, Yusaku; Takahashi, Mitsuo; Kitaguchi, Masataka; Akaneya, Yukio; Mitui, Yoshiyuki; Tanaka, Hisashi

    1991-01-01

    We studied eighteen patients affected by Parkinsonism with symptoms of tremor, bradykinesia, or rigidity using magnetic resonance imaging (MRI). Patients ranged in age from 34 to 80 years (mean 62.8±11.6 years), and the duration of their disease had been 3.8±3.2 years. MRI examinations were performed with Shimazu and Siemens superconducting magnets, operating at 0.5 and 1.5 T magnetic fields, respectively. Both T 1 - and T 2 -weighted spin echo (SE) pulse sequences were used. In eight patients (44.4%), MRI demonstrated bilateral multiple lacunar infarction of the basal ganglia. The most common abnormality identified was multiple, bilateral lacunar infarcts in the lateral portion of the putamen. The average size of the lacunar infarction of the putamen was less than half that of the entire putamen. Patients with multiple lacunar infarction were significantly older than the other patients and had lower Yahr's scores. The clinical symptoms of patients with bilateral multiple lacunar infarction of the basal ganglia were compatible with the diagnosis of arteriosclerotic Parkinsonism of akinetic rigid type. It has been suggested that multiple lacunar infarction of the basal ganglia may have led to Parkinsonism in these patients. (author)

  17. Nuclear magnetic resonance imaging method

    International Nuclear Information System (INIS)

    Johnson, G.; MacDonald, J.; Hutchison, S.; Eastwood, L.M.; Redpath, T.W.T.; Mallard, J.R.

    1984-01-01

    A method of deriving three dimensional image information from an object using nuclear magnetic resonance signals comprises subjecting the object to a continuous, static magnetic field and carrying out the following set of sequential steps: 1) exciting nuclear spins in a selected volume (90deg pulse); 2) applying non-aligned first, second and third gradients of the magnetic field; 3) causing the spins to rephase periodically by reversal of the first gradient to produce spin echoes, and applying pulses of the second gradient prior to every read-out of an echo signal from the object, to differently encode the spin in the second gradient direction for each read-out signal. The above steps 1-3 are then successively repeated with different values of gradient of the third gradient, there being a recovery interval between the repetition of successive sets of steps. Alternate echoes only are read out, the other echoes being time-reversed and ignored for convenience. The resulting signals are appropriately sampled, set out in an array and subjected to three dimensional Fourier transformation. (author)

  18. 14 GHz longitudinally detected electron spin resonance using microHall sensors

    Science.gov (United States)

    Bouterfas, M.; Mouaziz, S.; Popovic, R. S.

    2017-09-01

    In this work we developed a home-made LOngitudinally Detected Electron Spin Resonance (LODESR) spectrometer based on a microsize Hall sensor. A coplanar waveguide (CPW)-resonator is used to induce microwave-excitation on the sample at 14 GHz. We used InSb cross-shaped Hall devices with active areas of (10 μm × 10 μm) and (5 μm × 5 μm) . Signal intensities of the longitudinal magnetization component of DPPH and YIG samples of volumes about (10 μm) 3 and (5 μm) 3 , are measured under amplitude and frequency modulated microwave magnetic field generated by the CPW-resonator. At room temperature, 109spins /G √Hz sensitivity is achieved for 0.2mT linewidth, a result which is still better than most of inductive detected LODESR sensitivities.

  19. A review of magnetic resonance imaging in spinal trauma

    International Nuclear Information System (INIS)

    Davis, S.J.; Khangure, M.S.

    1994-01-01

    One hundred and ninety-five magnetic resonance (MR) images of 167 patients with neurological impairment following spinal trauma were reviewed. Acute cord injury produces central haemorrhagic necrosis that extends transversely and longitudinally with time and increased injury severity. Oedema appears more homogeneous, extensive and dominant in minimal lesions. Magnetic resonance appearances correlate with neurological status and outcome. Patients with MR evidence of cord blood had severe clinical lesions and failed to show useful clinical improvement. Patients with homogeneous 'oedema' improved to useful function. Lesion signal inhomogeneity relates to a worse prognosis. The clinical level correlates closely with cord blood or signal in homogeneity but imprecisely with homogeneous oedema. Disc herniations require differentiation from epidural blood and venous engorgement, which are prominent with bone displacement. Magnetic resonance is recommended in incomplete cord syndromes and in cord injuries with no apparent fracture, particularly of clinically deteriorating. 18 ref., 2 figs., 3 tabs

  20. Transition metal nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Pregosin, P.S.

    1991-01-01

    Transition metal NMR spectroscopy has progressed enormously in recent years. New methods, and specifically solid-state methods and new pulse sequences, have allowed access to data from nuclei with relatively low receptivities with the result that chemists have begun to consider old and new problems, previously unapproachable. Moreover, theory, computational science in particular, now permits the calculation of not just 13 C, 15 N and other light nuclei chemical shifts, but heavy main-group element and transition metals as well. These two points, combined with increasing access to high field pulsed spectrometer has produced a wealth of new data on the NMR transition metals. A new series of articles concerned with measuring, understanding and using the nuclear magnetic resonance spectra of the metals of Group 3-12 is presented. (author)

  1. Gaucher's disease: Magnetic resonance findings

    International Nuclear Information System (INIS)

    Roca, M.; Gomez-Pereda, R.; Blasco, A.; Ros, L.

    1996-01-01

    The objective is to assess the role of magnetic resonance (MR) in determining the initial extension of Gaucher's disease and its complications. A retrospective study of eight patients diagnosed as having Gaucher's disease was carried out using MR. The study focused on pelvis, hip, femur, spine, liver parenchyma and splenic parenchyma. Infiltration of the cancellous portion of the vertebral bodies was observed in all but one of the patients. Three patients presented small hemangiomas in dorsal and lumbar vertebral bodies. Pelvic bone involvement was homogeneous in four cases and spotty in two, while the pelvic marrow was normal in the two patients with no vertebral infiltration. A vascular necrosis of the femoral head was detected in two cases. MR is very useful in determining the initial extension, in the early diagnosis of complications and in managing the posttreatment marrow response to assess the therapeutic efficacy. 16 refs

  2. Fetal abdominal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2006-01-01

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages

  3. Fetal abdominal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages.

  4. Magnetic resonance imaging in neuroradiology

    International Nuclear Information System (INIS)

    Voigt, K.; Lotx, J.W.

    1990-01-01

    Magnetic resonance imaging (MRI) is now accepted as an effective method of investigating a wide range of disorders, especially of the brain and spine. A short introduction on image contrast in MRI is given and the advantages and disadvantages for the different diseases of the brain is discussed. Excellent soft-tissue contrast, multiplanar imaging capabilities and lack of ionising radiation are conspicuous advantages, and it is now established as the investigation of choice in a large number of clinical conditions, especially when the central nervous system is involved. However, it remains only one of a series of imaging modalities. A confident provisional clinical diagnosis is essential for establishing an imaging protocol and the intention should always be to reach a definitive diagnosis in the least invasive and most cost-effective way. 7 figs., 19 refs

  5. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  6. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  7. Single voxel magnetic resonance spectroscopy in distinguishing ...

    African Journals Online (AJOL)

    Objective: Assess diagnostic utility of combined magnetic resonance imaging and magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- neoplastic (infective or degenerative) brain lesions. Design: Descriptive, analytical - prospective study. Setting: The Aga Khan University ...

  8. Magnetic resonance imaging of radiation optic neuropathy

    International Nuclear Information System (INIS)

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S.

    1990-01-01

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence

  9. Magnetic resonance: discovery, investigations, and applications

    International Nuclear Information System (INIS)

    Kessenikh, Aleksandr V

    2009-01-01

    The history of the development of the theoretical ideas and experimental methods of magnetic resonance, as well as the applications of these methods in modern natural science, technology, and medicine, are outlined, with allowance for the contribution of Russian researchers. An assessment of some promising trends of studies and applications of magnetic resonance is given. (from the history of physics)

  10. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  11. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  12. Magnetic resonance imaging of hypophysis

    International Nuclear Information System (INIS)

    Malla Huesh, I. V.

    2016-01-01

    Hypothalamic-pituitary diseases represent with wide variety of symptoms in regard with changes in the endocrine function. Magnetic resonance imaging has a crucial role in detecting the morphologic appearance in physiologic conditions, malformative diseases and acquired pathologies. The MR-imaging is established as the method of choice in assessing the changes in the hypothalamic-pituitary axis. The pituitary gland is a complex structure with an important role in the homeostasis of the organism even though it is so small? It is surrounded by bony structures, vessels, nerves and the brain parenchyma. It consists of three parts - anterior called - adenohypophysis, posterior - neurohypophysis and pituitary stalk. The anterior part comprises about 75% of the gland. Computed tomography (CT) has a limited role in detecting the pituitary gland. It is mainly used in cases of elevated intracranial pressure due to suspected apoplexy. The gland's small size, relation to other structures and its soft tissue characteristic make it an accessible region of interest for detecting with MR-imaging. The lack of ionizing energy and the technical advances in the MR-methods are responsible for the creating images with better spatial resolution and signal to noise ratio. The examination is carried out on a standard protocol. It is important that thin slices are executed in sagittal and coronal planes. Performing a sequence, regarding the brain parenchyma is essential, since many malformations of the pituitary gland are associated with other congenital conditions. The examination starts with a T1W sequence to assess the normal anatomic condition of the gland. The intensity of the adenohypophysis is compared to the one in the pons. It is hypointense, whereas the neurohypophysis is hyperintense, due to the lipid neurosecretory granules transported along the hypothalamic-pituitary axis. T2W-images in coronal plane are used to evaluate the hypothalamus, pituitary stalk, optic chiasm, olfactory

  13. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.

  14. Longitudinal magnetic bistability of electroplated wires

    International Nuclear Information System (INIS)

    Kurlyandskaya, G.V.; Garcia-Miquel, H.; Vazquez, M.; Svalov, A.V.; Vas'kovskiy, V.O.

    2002-01-01

    Fe 20 Ni 74 Co 6 and Fe 20 Ni 64 Co 16 1 μm thick magnetic tubes electroplated onto Cu 98 Be 2 conductive wire have been investigated in as-deposited state, after heat treatment under longitudinal magnetic field for 1 h at 330 deg. C, and after rf-sputtering deposition of the additional 2 μm Fe 19 Ni 81 layer. Heat treatments and an additional layer deposition modify the shape of hysteresis loops. Magnetically bistable behaviour, observed after the field annealing at a temperature of 330 deg. C, is studied as a function of the length of the samples. This is the first report by our knowledge on the bistable behaviour of the electroplated wires. The bistability of these wires is promising for applications such as tagging or pulse generator applications

  15. The Default Mode Network as a Biomarker of Persistent Complaints after Mild Traumatic Brain Injury: A Longitudinal Functional Magnetic Resonance Imaging Study.

    Science.gov (United States)

    van der Horn, Harm J; Scheenen, Myrthe E; de Koning, Myrthe E; Liemburg, Edith J; Spikman, Jacoba M; van der Naalt, Joukje

    2017-12-01

    The objective of this study was to examine longitudinal functional connectivity of resting-state networks in patients with and without complaints after uncomplicated mild traumatic brain injury (mTBI). Second, we aimed to determine the value of network connectivity in predicting persistent complaints, anxiety, depression and long-term outcome. Thirty mTBI patients with three or more post-traumatic complaints at 2 weeks post-injury, 19 without complaints, and 20 matched healthy controls were selected for this study. Resting-state functional MRI (fMRI) was performed in patients at 1 month and 3 months post-injury, and once in healthy controls. Independent component analysis (ICA) was used to investigate the default mode, executive and salience networks. Persistent post-traumatic complaints, anxiety, and depression were measured at 3 months post-injury, and outcome was determined at 1 year post-injury. Within the group with complaints, higher functional connectivity between the anterior and posterior components of the default mode network at 1 month post-injury was associated with a greater number of complaints at 3 months post-injury (ρ = 0.59, p = 0.001). Minor longitudinal changes in functional connectivity were found for patients with and without complaints after mTBI, which were limited to connectivity within the precuneus component of the default mode network. No significant results were found for the executive and salience networks. Current results suggest that the default mode network may serve as a biomarker of persistent complaints in patients with uncomplicated mTBI.

  16. Force detection of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Rugar, D.; Zueger, O.; Hoen, S.; Yannoni, C.S.; Vieth, H.M.; Kendrick, R.D.

    1994-01-01

    Micromechanical sensing of magnetic force was used to detect nuclear magnetic resonance with exceptional sensitivity and spatial resolution. With a 900 angstrom thick silicon nitride cantilever capable of detecting subfemtonewton forces, a single shot sensitivity of 1.6 x 10 13 protons was achieved for an ammonium nitrate sample mounted on the cantilever. A nearby millimeter-size iron particle produced a 600 tesla per meter magnetic field gradient, resulting in a spatial resolution of 2.6 micrometers in one dimension. These results suggest that magnetic force sensing is a viable approach for enhancing the sensitivity and spatial resolution of nuclear magnetic resonance microimaging

  17. Magnetic resonance elastometry using a single-sided permanent magnet

    International Nuclear Information System (INIS)

    Tan, Carl S; Marble, Andrew E; Ono, Yuu

    2012-01-01

    In this paper, we describe a magnetic resonance method of measuring material elasticity using a single-sided magnet with a permanent static field gradient. This method encodes sample velocity in a reciprocal space using Hahn spin-echoes with variable timing. The experimental results show a strong correlation between magnetic resonance signal attenuation and elasticity when an oscillating force is applied on the sample. This relationship in turn provides us with information about the displacement velocity experienced by the sample, which is inversely proportional to Young's modulus. The proposed method shows promise in offering a portable and cost-effective magnetic resonance elastography system. (paper)

  18. Artifacts in Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Krupa, Katarzyna; Bekiesińska-Figatowska, Monika

    2015-01-01

    Artifacts in magnetic resonance imaging and foreign bodies within the patient’s body may be confused with a pathology or may reduce the quality of examinations. Radiologists are frequently not informed about the medical history of patients and face postoperative/other images they are not familiar with. A gallery of such images was presented in this manuscript. A truncation artifact in the spinal cord could be misinterpreted as a syrinx. Motion artifacts caused by breathing, cardiac movement, CSF pulsation/blood flow create a ghost artifact which can be reduced by patient immobilization, or cardiac/respiratory gating. Aliasing artifacts can be eliminated by increasing the field of view. An artificially hyperintense signal on FLAIR images can result from magnetic susceptibility artifacts, CSF/vascular pulsation, motion, but can also be found in patients undergoing MRI examinations while receiving supplemental oxygen. Metallic and other foreign bodies which may be found on and in patients’ bodies are the main group of artifacts and these are the focus of this study: e.g. make-up, tattoos, hairbands, clothes, endovascular embolization, prostheses, surgical clips, intraorbital and other medical implants, etc. Knowledge of different types of artifacts and their origin, and of possible foreign bodies is necessary to eliminate them or to reduce their negative influence on MR images by adjusting acquisition parameters. It is also necessary to take them into consideration when interpreting the images. Some proposals of reducing artifacts have been mentioned. Describing in detail the procedures to avoid or limit the artifacts would go beyond the scope of this paper but technical ways to reduce them can be found in the cited literature

  19. Low field magnetic resonance experiments in superfluid 3He--A

    International Nuclear Information System (INIS)

    Gully, W.J. Jr.

    1976-01-01

    Measurements of the longitudinal and transverse nuclear magnetic resonance signals have been made on the A phase of liquid 3 He. They were performed on a sample of 3 He self-cooled by the Pomeranchuk effect to the critical temperature of the superfluid at 2.7 m 0 K. The longitudinal resonance is a magnetic mode of the liquid excited by radio frequency magnetic fields applied in the direction of the static magnetic field. Frequency profiles of this resonance were indirectly obtained by contour techniques from signals recorded by sweeping the temperature. Its frequency is found to be related to the frequency shift of the transverse resonance in agreement with theoretical predictions for the ABM pairing state. Its linewidth also agrees with theoretical predictions based upon dissipative phenomena peculiar to the superfluid phase. An analysis of the linewidth of the longitudinal resonance yields a value for the quasiparticle collision time. Transverse NMR lines were also studied. In low magnetic fields (20 Oersted) these lines were found to become extremely broad. This is shown to be a manifestation of the same collisional processes that broaden the longitudinal resonance lines. Also, the effects of various textures on the resonance lines are discussed, including the results of an attempt to create a single domain of 3 He with crossed electric and magnetic fields

  20. Magnetic resonance in obstructive jaundice

    International Nuclear Information System (INIS)

    Gupta, R.K.; Jena, A.; Khushu, S.; Kakar, A.K.; Mishra, P.K.

    1989-01-01

    Twelve cases of obstructive jaundice in whom ultrasound failed to demonstrate the site and/or the cause of obstruction of the biliary tract were examined with magnetic resonance imaging (MRI), correctly diagnosing the site and cause of obstruction in 10 of 12 surgically proven cases. In one case of cholangiocarcinoma, the site of obstruction was well shown on MR but a definite cause could not be ascertained. In another patient who developed intermittent jaundice following surgery for choledochal cyst, MR demonstrated a solitary stone in the common hepatic duct. Surgical confirmation could not be achieved as the patient was lost to follow up. There were 6 cases of choledocholithiasis, 3 cases of gall bladder carcinoma and one case each of pancreatic adenocarcinoma and cholangiocarcinoma. It is believed that MRI will provide obstructive jaundice and will be able to minimize the use of percutaneous transhepatic cholangiography (PTC) and endoscopic retrograde cholangiopancreatography (ERCP) in view of its ability to perform multiplanar imaging in multiple sequences. 11 refs., figs., 1 tab

  1. Low rank magnetic resonance fingerprinting.

    Science.gov (United States)

    Mazor, Gal; Weizman, Lior; Tal, Assaf; Eldar, Yonina C

    2016-08-01

    Magnetic Resonance Fingerprinting (MRF) is a relatively new approach that provides quantitative MRI using randomized acquisition. Extraction of physical quantitative tissue values is preformed off-line, based on acquisition with varying parameters and a dictionary generated according to the Bloch equations. MRF uses hundreds of radio frequency (RF) excitation pulses for acquisition, and therefore high under-sampling ratio in the sampling domain (k-space) is required. This under-sampling causes spatial artifacts that hamper the ability to accurately estimate the quantitative tissue values. In this work, we introduce a new approach for quantitative MRI using MRF, called Low Rank MRF. We exploit the low rank property of the temporal domain, on top of the well-known sparsity of the MRF signal in the generated dictionary domain. We present an iterative scheme that consists of a gradient step followed by a low rank projection using the singular value decomposition. Experiments on real MRI data demonstrate superior results compared to conventional implementation of compressed sensing for MRF at 15% sampling ratio.

  2. Presurgical functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Stippich, C.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is an important and novel neuroimaging modality for patients with brain tumors. By non-invasive measurement, localization and lateralization of brain activiation, most importantly of motor and speech function, fMRI facilitates the selection of the most appropriate and sparing treatment and function-preserving surgery. Prerequisites for the diagnostic use of fMRI are the application of dedicated clinical imaging protocols and standardization of the respective imaging procedures. The combination with diffusion tensor imaging (DTI) also enables tracking and visualization of important fiber bundles such as the pyramidal tract and the arcuate fascicle. These multimodal MR data can be implemented in computer systems for functional neuronavigation or radiation treatment. The practicability, accuracy and reliability of presurgical fMRI have been validated by large numbers of published data. However, fMRI cannot be considered as a fully established modality of diagnostic neuroimaging due to the lack of guidelines of the responsible medical associations as well as the lack of medical certification of important hardware and software components. This article reviews the current research in the field and provides practical information relevant for presurgical fMRI. (orig.) [de

  3. Endometrial cancer: magnetic resonance imaging.

    Science.gov (United States)

    Manfredi, R; Gui, B; Maresca, G; Fanfani, F; Bonomo, L

    2005-01-01

    Carcinoma of the endometrium is the most common invasive gynecologic malignancy of the female genital tract. Clinically, patients with endometrial carcinoma present with abnormal uterine bleeding. The role of magnetic resonance imaging (MRI) in endometrial carcinoma is disease staging and treatment planning. MRI has been shown to be the most valuable imaging mod-ality in this task, compared with endovaginal ultrasound and computed tomography, because of its intrinsic contrast resolution and multiplanar capability. MRI protocol includes axial T1-weighted images; axial, sagittal, and coronal T2-weighted images; and dynamic gadolinium-enhanced T1-weighted imaging. MR examination is usually performed in the supine position with a phased array multicoil using a four-coil configuration. Endometrial carcinoma is isointense with the normal endometrium and myometrium on noncontrast T1-weighted images and has a variable appearance on T2-weighted images demonstrating heterogeneous signal intensity. The appearance of noninvasive endometrial carcinoma on MRI is characterized by a normal or thickened endometrium, with an intact junctional zone and a sharp tumor-myometrium interface. Invasive endometrial carcinoma is characterized disruption or irregularity of the junctional zone by intermediate signal intensity mass on T2-weighted images. Invasion of the cervical stroma is diagnosed when the low signal intensity cervical stroma is disrupted by the higher signal intensity endometrial carcinoma. MRI in endometrial carcinoma performs better than other imaging modalities in disease staging and treatment planning. Further, the accuracy and the cost of MRI are equivalent to those of surgical staging.

  4. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  5. Magnetic resonance imaging and neurolupus

    International Nuclear Information System (INIS)

    Schott, A.M.; Colson, F.; Tebib, J.; Noel, E.; Bouvier, M.

    1990-01-01

    Magnetic resonance imaging (MRI) was assessed in the management of neuropsychiatric manifestations occurring in 6 SLE patients. The MRI scans were normal in 3 cases and was associated with remission of the symptoms except for a patient who experienced a chorea at the time of the examination. Abnormal MRI scans always revealed more lesions than CT scan. 2 different patterns of abnormalities seem to correspond to 2 specific disorders. In 2 patients with clinical presentation suggesting a cortical ischemia by vascular thrombosis, both MRI scans showed areas of abnormal high signal intensities located in the subcortical white matter. In one last patient, MRI scan revealed multiple focal areas of high signal intensities (on T 1 weighter scans) disseminated not only in the deep white matter but also in the gray one. These lesions could be depend upon demyelinisation which may occur by a local vascular process. This serie confirms the interest of MRI in the management of SLE brain involvement as well as it points out some problem of interpretation. This suggest further comparative studies especially at the real onset and during the course of neuro-psychiatric manifestations. At last, the coronal sections may be more informative for the diagnosis and patholophysiology than the horizontal ones [fr

  6. Magnetic resonance in multiple sclerosis

    International Nuclear Information System (INIS)

    Scotti, G.; Caputo, D.; Cazzullo, C.L.

    1986-01-01

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres. (orig.)

  7. Myositis ossificans: magnetic resonance images

    International Nuclear Information System (INIS)

    Dosda, R.; Marti-Bonmati, L.; Concepcion, L.; Galant, J.

    1999-01-01

    Myositis ossificans is characterized by a benign, self-limiting, ossifying mass of the white tissue. In the present report, we describe the magnetic resonance (MR) images in three cases of myositis ossificans in pediatric patients, correlating the MR findings with those obtained with other radiological studies. The lesions were detected in three patients, two boys and one girl, ranging in age between 10 and 14 years. The nature of the lesion was confirmed histologically in all three cases. The MR images were obtained using superconductive units at 0.5 Teslas, with T1 and T2-weighted spin-echo and STIR sequences. In two patients, gadolinium-enhanced T1-weighted images were also obtained. As in any process of maturation, the proliferation/maturation ratio depends on the moment in the course of the lesion, which affects its MR features,. In acute phases, the soft tissue mass with an intraosseous, perilesional adematous reaction predominates, while annular calcification and lesser edema are characteristic of subacute episode. Myositis ossificans is very rare in children. The inflammatory response may present a radiological pattern difficult to distinguish from that of aggressive tumor or infection, especially in the acute phase. (Author) 7 refs

  8. Cardiovascular magnetic resonance in congenital heart disease

    International Nuclear Information System (INIS)

    Cazacu, A.; Ciubotaru, A.

    2010-01-01

    The increasing prevalence of congenital heart disease can be attributed to major improvements in diagnosis and treatment. Cardiovascular magnetic resonance imaging plays an important role in the clinical management strategy of patients with congenital heart disease. The development of new cardiovascular magnetic resonance (CMR) techniques allows comprehensive assessment of complex cardiac anatomy and function and provides information about the long-term residual post-operative lesions and complications of surgery. It overcomes many of the limitations of echocardiography and cardiac catheterization. This review evaluates the role of cardiovascular magnetic resonance imaging modality in the management of subject with congenital heart disease (CHD). (authors)

  9. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    Nishimura, Yukiko; Negoro, Kiyoshi; Morimatsu, Mitsunori; Hashida, Masahiro

    1996-01-01

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  10. NMR magnetic field controller for pulsed nuclear magnetic resonance experiments

    International Nuclear Information System (INIS)

    Scheler, G.; Anacker, M.

    1975-01-01

    A nuclear magnetic resonance controller for magnetic fields, which can also be used for pulsed NMR investigations, is described. A longtime stability of 10 -7 is achieved. The control signal is generated by a modified time sharing circuit with resonance at the first side band of the 2 H signal. An exact calibration of the magnetic field is achieved by the variation of the H 1 - or of the time-sharing frequency. (author)

  11. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  12. AGS Fast spin resonance jump, magnets and power supplies

    International Nuclear Information System (INIS)

    Glenn, J.W.; Huang, H.; Liaw, C. J.; Marneris, I.; Meng, W.; Mi, J. L.; Rosas, P.; Sandberg, J.; Tuozzolo, J.; Zhang, A.

    2009-01-01

    In order to cross more rapidly the 82 weak spin resonances caused by the horizontal tune and the partial snakes, we plan to jump the horizontal tune 82 times during the acceleration of polarized protons. The current in the magnets creating this tune jump will rise in 100 (micro)s, hold flat for about 4 ms and fan to zero in 100 (micro)s. Laminated beam transport quadrupole magnets have been recycled by installing new two turn coils and longitudinal laminated pole tip shims that reduce inductance and power supply current. The power supply uses a high voltage capacitor discharge to raise the magnet current, which is then switched to a low voltage supply, and then the current is switched back to the high voltage capacitor to zero the current. The current in each of the magnet pulses must match the order of magnitude change in proton momentum during the acceleration cycle. The magnet, power supply and operational experience are described

  13. Magnetic characterisation of longitudinal thin film media

    International Nuclear Information System (INIS)

    Dova, P.

    1998-09-01

    Magnetic characterisation techniques, as applied to longitudinal thin film media, have been investigated. These included the study of the differentials of the remanence curves, the delta-M plot and the examination of the critical volumes. Several thin film structures, which are currently used or are being considered for future media applications, have been examined using these techniques. Most of the films were Co-alloys with the exception of a set of Barium ferrite films. Both monolayer and multilayer structures were studied. It was found that the study of activation volumes provides a better insight into the reversal mechanisms of magnetic media, especially in the case of complex structures such as multilayer films and films with bicrystal microstructure. Furthermore, an evaluation study of different methods of determining critical volumes showed that the method using time dependence measurements and the micromagnetic approach is the most appropriate. The magnetic characteristics of the thin film media under investigation were correlated with their microstructure and, where possible, with their noise performance. Magnetic force microscopy was also used for acquiring quasi-domain images in the ac-demagnetised state. It was found that in all Co-alloy films the dominant intergranular coupling is magnetising in nature, the level of which is governed by the Cr content in the magnetic layer. In the case of laminated media it was found that when non-magnetic spacers are used, the nature of the interlayer coupling depends on the spacer thickness. In double layer structures with no spacer, the top layer replicates the crystallographic texture of the bottom layer, and the overall film properties are a combination of the two layers. In bicrystal films the coupling is determined by the Cr segregation in the grain boundaries. Furthermore, the presence of stacking faults in bicrystal films deteriorates their thermal stability, but can be prevented by improving the epitaxial

  14. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  15. Pocket atlas of cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Haughton, V.M.; Daniels, D.L.

    1986-01-01

    This atlas illustrates normal cerebral anatomy in magnetic resonance images. From their studies in cerebral anatomy utilizing cryomicrotome and other techniques, the authors selected more than 100 high-resolution images that represent the most clinically useful scans

  16. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  17. Fifty years of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Martinez Valderrama, Juan Crisostomo

    1997-01-01

    Short information about the main developments of nuclear magnetic resonance during their fifty existence years is presented. Beside two examples of application (HETCOR and INADEQUATE) to the structural determination of organic compounds are described

  18. Principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Pykett, I.L.; Newhouse, J.H.; Buonanno, F.S.; Brady, T.J.; Goldman, M.R.; Kistler, J.P.; Pohost, G.M.

    1982-01-01

    The physical principles which underlie the phenomenon of nuclear magnetic resonance (NMR) are presented in this primer. The major scanning methods are reviewed, and the principles of technique are discussed. A glossary of NMR terms is included

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  20. The role of magnetic resonance cholangiopancreatography and ...

    African Journals Online (AJOL)

    ) is accepted as the gold standard, there is a place for magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted imaging (DWI) in the diagnosis of obstructive biliary disorders. Aim: To compare the findings of MRCP with ...

  1. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  2. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  3. Chronic liver disease: evaluation by magnetic resonance

    International Nuclear Information System (INIS)

    Stark, D.D.; Goldberg, H.I.; Moss, A.A.; Bass, N.M.

    1984-01-01

    Magnetic resonance (MR) imaging distinguished hepatitis from fatty liver and cirrhosis in a woman with a history of alcohol abuse. Anatomic and physiologic manifestations of portal hypertension were also demonstrated by MR

  4. Nuclear Magnetic Resonance Trackbed Moisture Sensor System

    Science.gov (United States)

    2018-02-01

    In this initial phase, conducted from March 2015 through December 2016, Vista Clara and its subcontractor Zetica Rail successfully developed and tested a man-portable, non-invasive spot-check nuclear magnetic resonance (NMR) moisture sensor that dire...

  5. Magnetic Resonance Imaging Features of Neuromyelitis Optica

    Energy Technology Data Exchange (ETDEWEB)

    You, Sun Kyung; Song, Chang June; Park, Woon Ju; Lee, In Ho; Son, Eun Hee [Chungnam National University College of Medicine, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2013-03-15

    To report the magnetic resonance (MR) imaging features of the spinal cord and brain in patients of neuromyelitis optica (NMO). Between January 2001 and March 2010, the MR images (spinal cord, brain, and orbit) and the clinical and serologic findings of 11 NMO patients were retrospectively reviewed. The contrast-enhancement of the spinal cord was performed (20/23). The presence and pattern of the contrast-enhancement in the spinal cord were classified into 5 types. Acute myelitis was monophasic in 8 patients (8/11, 72.7%); and optic neuritis preceded acute myelitis in most patients. Longitudinally extensive cord lesion (average, 7.3 vertebral segments) was involved. The most common type was the diffuse and subtle enhancement of the spinal cord with a multifocal nodular, linear or segmental intense enhancement (45%). Most of the brain lesions (5/11, 10 lesions) were located in the brain stem, thalamus and callososeptal interphase. Anti-Ro autoantibody was positive in 2 patients, and they showed a high relapse rate of acute myelitis. Anti-NMO IgG was positive in 4 patients (4/7, 66.7%). The imaging findings of acute myelitis in NMO may helpful in making an early diagnosis of NMO which can result in a severe damage to the spinal cord, and to make a differential diagnosis of multiple sclerosis and inflammatory diseases of the spinal cord such as toxocariasis.

  6. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  7. Magnetic Resonance Imaging Features of Neuromyelitis Optica

    International Nuclear Information System (INIS)

    You, Sun Kyung; Song, Chang June; Park, Woon Ju; Lee, In Ho; Son, Eun Hee

    2013-01-01

    To report the magnetic resonance (MR) imaging features of the spinal cord and brain in patients of neuromyelitis optica (NMO). Between January 2001 and March 2010, the MR images (spinal cord, brain, and orbit) and the clinical and serologic findings of 11 NMO patients were retrospectively reviewed. The contrast-enhancement of the spinal cord was performed (20/23). The presence and pattern of the contrast-enhancement in the spinal cord were classified into 5 types. Acute myelitis was monophasic in 8 patients (8/11, 72.7%); and optic neuritis preceded acute myelitis in most patients. Longitudinally extensive cord lesion (average, 7.3 vertebral segments) was involved. The most common type was the diffuse and subtle enhancement of the spinal cord with a multifocal nodular, linear or segmental intense enhancement (45%). Most of the brain lesions (5/11, 10 lesions) were located in the brain stem, thalamus and callososeptal interphase. Anti-Ro autoantibody was positive in 2 patients, and they showed a high relapse rate of acute myelitis. Anti-NMO IgG was positive in 4 patients (4/7, 66.7%). The imaging findings of acute myelitis in NMO may helpful in making an early diagnosis of NMO which can result in a severe damage to the spinal cord, and to make a differential diagnosis of multiple sclerosis and inflammatory diseases of the spinal cord such as toxocariasis.

  8. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  9. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  10. Concepts and indications of abdominal magnetic resonance

    International Nuclear Information System (INIS)

    Murillo Viera, Wendy

    2012-01-01

    A literature review and conceptualization was performed of the main indications of magnetic resonance studies of the abdomen and the characteristic findings for each sequence, according to organ and pathology. The radiologist has had in mind main indications for magnetic resonance studies of the abdomen, with the purpose to guide the clinician in the choice of imaging modality that works best for the patient at diagnosis [es

  11. Magnetic resonance imaging of muscle tears

    International Nuclear Information System (INIS)

    De Smet, A.A.; Fisher, D.R.; Heiner, J.P.; Keene, J.S.

    1990-01-01

    Magnetic resonance scans were obtained on 17 patients with acute, subacute, or chronic muscle tears. These patients presented with complaints of persistent pain or a palpable mass. Magnetic resonance findings were characterized according to alterations in muscle shape and the presence of abnormal high signal within the injured muscle. These areas of high signal were noted on both T1-weighted and T2-weighted scans and were presumed to represent areas of intramuscular hemorrhage. (orig.)

  12. Clinical magnetic resonance: imaging and spectroscopy

    International Nuclear Information System (INIS)

    Andrew, E.R.; Bydder, Graeme; Griffiths, John; Iles, Richard; Styles, Peter

    1990-01-01

    This book begins with a readable, comprehensive but non-mathematical introduction to the basic underlying principles of magnetic resonance. Further chapters include information on the theory and principles of MRI and MRS, the interpretation of MR images, the clinical applications and scope of MRI and MRS, practical aspects of spectroscopy and magnetic resonance, and also the practical problems associated with the siting, safety and operation of large MRI and MRS equipment. (author)

  13. Longitudinally mounted light emitting plasma in a dielectric resonator

    Energy Technology Data Exchange (ETDEWEB)

    Gilliard, Richard; DeVincentis, Marc; Hafidi, Abdeslam; O' Hare, Daniel; Hollingsworth, Gregg [LUXIM Corporation, 1171 Borregas Avenue, Sunnyvale, CA 94089 (United States)

    2011-06-08

    Methods for coupling power from a dielectric resonator to a light-emitting plasma have been previously described (Gilliard et al IEEE Trans. Plasma Sci. at press). Inevitably, regardless of the efficiency of power transfer, much of the emitted light is absorbed in the resonator itself which physically surrounds much if not all of the radiating material. An investigation into a method is presented here for efficiently coupling power to a longitudinally mounted plasma vessel which is mounted on the surface of the dielectric material of the resonator, thereby eliminating significant absorption of light within the resonator structure. The topology of the resonator and its physical properties as well as those of the metal halide plasma are presented. Results of basic models of the field configuration and plasma are shown as well as a configuration suitable as a practical light source.

  14. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Burl, M.; Young, I.R.

    1984-01-01

    A method and apparatus for determining the rate of flow of a liquid in a selected region of a body by nuclear magnetic resonance techniques are described. The method includes a sequence of applying a first magnetic pulse effective to excite nuclear magnetic resonance of a chosen nucleus within the liquid preferentially in a slice of the body which includes the selected region. A period of time (tsub(D)) is waited and then a second magnetic pulse is applied which is effective to excite nuclear magnetic resonance of the nuclei preferentially in the slice, and the free induction decay signal is measured. The whole sequence is repeated for different values of the period of time (tsub(D)). The variation in the value of the measured signal with tsub(D) is then related to the rate of flow of the liquid through the slice. (author)

  15. Resonance double magnetic bremsstrahlung in a strong magnetic field

    International Nuclear Information System (INIS)

    Fomin, P.I.; Kholodov, R.I.

    2003-01-01

    The possibility of resonance double magnetic bremsstrahlung in the approximation of weakly excited electron states in a strong external magnetic field is analyzed. The differential probability of this process in the Breit-Wigner form is obtained. The probability of double magnetic bremsstrahlung (second-order process of perturbation theory) is compared with the probability of magnetic bremsstrahlung (first-order process of perturbation theory)

  16. Rapid parametric mapping of the longitudinal relaxation time T1 using two-dimensional variable flip angle magnetic resonance imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla.

    Science.gov (United States)

    Dieringer, Matthias A; Deimling, Michael; Santoro, Davide; Wuerfel, Jens; Madai, Vince I; Sobesky, Jan; von Knobelsdorff-Brenkenhoff, Florian; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2014-01-01

    Visual but subjective reading of longitudinal relaxation time (T1) weighted magnetic resonance images is commonly used for the detection of brain pathologies. For this non-quantitative measure, diagnostic quality depends on hardware configuration, imaging parameters, radio frequency transmission field (B1+) uniformity, as well as observer experience. Parametric quantification of the tissue T1 relaxation parameter offsets the propensity for these effects, but is typically time consuming. For this reason, this study examines the feasibility of rapid 2D T1 quantification using a variable flip angles (VFA) approach at magnetic field strengths of 1.5 Tesla, 3 Tesla, and 7 Tesla. These efforts include validation in phantom experiments and application for brain T1 mapping. T1 quantification included simulations of the Bloch equations to correct for slice profile imperfections, and a correction for B1+. Fast gradient echo acquisitions were conducted using three adjusted flip angles for the proposed T1 quantification approach that was benchmarked against slice profile uncorrected 2D VFA and an inversion-recovery spin-echo based reference method. Brain T1 mapping was performed in six healthy subjects, one multiple sclerosis patient, and one stroke patient. Phantom experiments showed a mean T1 estimation error of (-63±1.5)% for slice profile uncorrected 2D VFA and (0.2±1.4)% for the proposed approach compared to the reference method. Scan time for single slice T1 mapping including B1+ mapping could be reduced to 5 seconds using an in-plane resolution of (2×2) mm2, which equals a scan time reduction of more than 99% compared to the reference method. Our results demonstrate that rapid 2D T1 quantification using a variable flip angle approach is feasible at 1.5T/3T/7T. It represents a valuable alternative for rapid T1 mapping due to the gain in speed versus conventional approaches. This progress may serve to enhance the capabilities of parametric MR based lesion detection and

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. Your child will lie on a moveable examination ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  3. Magnetic islands created by resonant helical windings

    International Nuclear Information System (INIS)

    Fernandes, A.S.; Heller, M.V.; Caldas, I.L.

    1986-01-01

    The triggering of disruptive instabilities by resonant helical windings in large aspect-ratio tokamaks is associated to destruction of magnetic surfaces. The Chirikov condition is applied to estimate analytically the helical winding current thresholds for ergodization of the magnetic field lines. (Autor) [pt

  4. Topical questions in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.; Florida Univ., Gainesville, FL; Florida Univ., Gainesville, FL

    1989-01-01

    This paper examines a number of practical questions concerning magnetic resonance imaging. These include the choice of operating magnetic field strength, the problem of siting and screening, a procedure for securing precise slice selection and the use of paramagnetic contrast agents. (author). 5 refs

  5. Basis of the nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Bahceli, S.

    1996-08-01

    The aim of this book which is translated from English language is to explain the physical and mathematical basis of nuclear magnetic resonance (NMR). There are nine chapters covering different aspects of NMR. In the firs chapter fundamental concepts of quantum mechanics are given at a level suitable for readers to understand NMR fully. The remaining chapters discuss the magnetic properties of nucleus, the interactions between atoms and molecules, continuous wave NMR, pulsed NMR, nuclear magnetic relaxation and NMR of liquids

  6. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  7. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  8. Magnetic resonance imaging: effects of magnetic field strength

    International Nuclear Information System (INIS)

    Crooks, L.E.; Arakawa, M.; Hoenninger, J.; McCarten, B.; Watts, J.; Kaufman, L.

    1984-01-01

    Magnetic resonance images of the head, abdomen, and pelvis of normal adult men were obtained using varying magnetic field strength, and measurements of T1 and T2 relaxations and of signal-to-noise (SN) ratios were determined. For any one spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part, and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields

  9. Diagnostic apparatus employing nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Hoshino, K.; Yamada, N.; Yoshitome, E.; Matsuura, H.

    1987-01-01

    An NMR diagnostic apparatus is described comprising means for applying a primary magnetic field to a subject; means for applying RF pulses to the subject to give nuclear magnetic resonance to the nuclei of atoms in the subject; means for applying gradient magnetic fields to project an NMR signal of the nuclei at least in one direction; means for observing the NMR signal projected by the gradient magnetic fields applying means; and arithmetic means for constructing a distribution of information on resonance energy as an image from an output signal from the observing means; wherein the gradient magnetic fields applying means comprises means for applying the gradient magnetic fields at a predetermined time and for not applying the gradient magnetic fields at another predetermined time, during the time period of one view; and wherein the gradient magnetic fields applying means further comprises means for measuring the NMR signal during the predetermined time when the gradient magnetic fields are applied, and means for measuring the intensity of the primary magnetic field during the other predetermined time when no gradient magnetic fields are applied

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... vision or seizures help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... moveable examination table that slides into the center of the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  11. Transport and magnetic resonance in normal and superfluid Fermi liquids

    International Nuclear Information System (INIS)

    Smith, H.

    1976-10-01

    This thesis provides a framework for a series of 19 papers published by the author in a study of transport and magnetic resonance in normal and superfluid Fermi liquids. The Boltzmann equation and methods for its solution are discussed. Electron-electron scattering in metals, with particular emphasis on alkali metals, is considered. Transport in a normal uncharged Fermi liquid such as pure 3 He at temperatures well below its degeneracy temperature of approximately 1 K or mixtures of 3 He in 4 He with degeneracy temperatures ranging typically from 100 to 200 mk is discussed with emphasis on comparison with experiments with the aim of testing models of the particle-particle scattering amplitude. Transport and magnetic resonance in superfluid 3 He is considered. The phenomenological treatment of relaxation is reviewed and the magnitude of the phenomenlogical relaxation time close to Tsub(c) is derived for the case of longitudinal resonance. Comments are made on non-linear magnetic resonance and textures and spin waves. (B.R.H.)

  12. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn; Creber, Sarah A.; Vrouwenvelder, Johannes S.; Johns, Michael L.

    2015-01-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  13. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  14. Generation of nuclear magnetic resonance images

    International Nuclear Information System (INIS)

    Beckmann, N.X.

    1986-01-01

    Two generation techniques of nuclear magnetic resonance images, the retro-projection and the direct transformation method are studied these techniques are based on the acquisition of NMR signals which phases and frequency components are codified in space by application of magnetic field gradients. The construction of magnet coils is discussed, in particular a suitable magnet geometry with polar pieces and air gap. The obtention of image contrast by T1 and T2 relaxation times reconstructed from generated signals using sequences such as spin-echo, inversion-recovery and stimulated echo, is discussed. The mathematical formalism of matrix solution for Bloch equations is also presented. (M.C.K.)

  15. Susceptibility effects in nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ziener, Christian Herbert

    2008-01-01

    The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed. (orig.)

  16. Magnetic resonance imaging in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) of the brain was performed in a total of 45 patients with multiple sclerosis (MS), comprising 27 with brain symptoms and 18 without it. The results were compared with X-ray computed tomography (CT). Some of the 45 MS patients were also examined by neurophysiological studies for comparison. MRI showed demyelinating plaques of the brain in a total of 31 patients (69%) - 20 symptomatic and 11 asymptomatic patients. For symptomatic patients, MRI was capable of detecting brain lesions in 6 (86%) of 7 acute stage patients and 14 (70%) of 20 non-acute stage patients. It was also capable of detecting brain lesions in 21 (70%) of 30 clinically definite MR patients and 10 (67%) of 15 clinically probable MS patients. Concurrently available X-ray CT revealed brain lesions in 9 symptomatic patients (33%) and one asymptomatic patient (6%). Visual evoked potentials examined in 31 patients showed abnormality in one (11%) of 9 patients without symptoms of optic neuritis and all (100%) of the other 22 patients with symptoms. In 19 evaluable patients, auditory brainstem responses were abnormal in one (11%) of 9 patients without brainstem symptoms and 3 (30%) of 10 patients with symptoms. MRI of the brain was far superior to X-ray CT, visual evoked potentials and auditory brainstem responses in detecting clinically unsuspected lesions. We proposed new diagnostic criteria including MRI findings of the brain in the Japanese MS diagnostic criteria. MRI of the spinal cord was performed in 12 MS patients with spinal cord symptoms by sagittal and coronal images. It demonstrated demyelinating lesions within the cervical and superior thoracic cord in 8 MS acute stage patients. Spinal cord lesions were longitudinally continuous as long as many spinal segments, with swelling in 6 patients and atrophy in 2 patients. MRI of spinal cord was useful in deciding superior and inferior limits of cord lesions and in visualizing cord swelling or atrophy. (Namekawa, K)

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic ... the radiologist if your child has any serious health problems or has recently had surgery. Some conditions, ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, ... to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI is ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... material called gadolinium, which is less likely to cause an allergic reaction than iodinated contrast material. Tell ... magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so you should let the radiologist know about them. ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so the radiologist should be aware of them. Parents ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if your child has asthma. The contrast ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... the MRI equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... lodged in the eyes are particularly important. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so the radiologist should be ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. You will lie ... your skin at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. Your child will ... skin irritation at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... regular daily routine and have him/her take food and medications as usual. Some MRI examinations may ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fluid spaces within the brain (ventricles) causes of epilepsy (seizure) hemorrhage in selected trauma patients certain chronic ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... two-way intercom. Many MRI centers allow a parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it ... the exam if your child has a known allergy to contrast material. Your child should wear loose, ...

  10. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  11. RESONANT ABSORPTION OF AXISYMMETRIC MODES IN TWISTED MAGNETIC FLUX TUBES

    Energy Technology Data Exchange (ETDEWEB)

    Giagkiozis, I.; Verth, G. [Solar Plasma Physics Research Centre, School of Mathematics and Statistics, University of Sheffield, Hounsfield Road, Hicks Building, Sheffield, S3 7RH (United Kingdom); Goossens, M.; Doorsselaere, T. Van [Centre for mathematical Plasma Astrophysics, Mathematics Department, KU Leuven, Celestijnenlaan 200B bus 2400, B-3001 Leuven (Belgium); Fedun, V. [Department of Automatic Control and Systems Engineering, University of Sheffield, Mappin Street, Amy Johnson Building, Sheffield, S1 3JD (United Kingdom)

    2016-06-01

    It has been shown recently that magnetic twist and axisymmetric MHD modes are ubiquitous in the solar atmosphere, and therefore the study of resonant absorption for these modes has become a pressing issue because it can have important consequences for heating magnetic flux tubes in the solar atmosphere and the observed damping. In this investigation, for the first time, we calculate the damping rate for axisymmetric MHD waves in weakly twisted magnetic flux tubes. Our aim is to investigate the impact of resonant damping of these modes for solar atmospheric conditions. This analytical study is based on an idealized configuration of a straight magnetic flux tube with a weak magnetic twist inside as well as outside the tube. By implementing the conservation laws derived by Sakurai et al. and the analytic solutions for weakly twisted flux tubes obtained recently by Giagkiozis et al. we derive a dispersion relation for resonantly damped axisymmetric modes in the spectrum of the Alfvén continuum. We also obtain an insightful analytical expression for the damping rate in the long wavelength limit. Furthermore, it is shown that both the longitudinal magnetic field and the density, which are allowed to vary continuously in the inhomogeneous layer, have a significant impact on the damping time. Given the conditions in the solar atmosphere, resonantly damped axisymmetric modes are highly likely to be ubiquitous and play an important role in energy dissipation. We also suggest that, given the character of these waves, it is likely that they have already been observed in the guise of Alfvén waves.

  12. Longitudinal detection of ferromagnetic resonance using x-ray transmission measurements

    International Nuclear Information System (INIS)

    Boero, G.; Rusponi, S.; Kavich, J.; Rizzini, A. Lodi; Piamonteze, C.; Nolting, F.; Tieg, C.; Thiele, J.-U.; Gambardella, P.

    2009-01-01

    We describe a setup for the x-ray detection of ferromagnetic resonance in the longitudinal geometry using element-specific transmission measurements. Thin magnetic film samples are placed in a static magnetic field collinear with the propagation direction of a polarized soft x-ray beam and driven to ferromagnetic resonance by a continuous wave microwave magnetic field perpendicular to it. The transmitted photon flux is measured both as a function of the x-ray photon energy and as a function of the applied static magnetic field. We report experiments performed on a 15 nm film of doped Permalloy (Ni 73 Fe 18 Gd 7 Co 2 ) at the L 3 /L 2 -edges of Fe, Co, and Ni. The achieved ferromagnetic resonance sensitivity is about 0.1 monolayers/√(Hz). The obtained results are interpreted in the framework of a conductivity tensor based formalism. The factors limiting the sensitivity as well as different approaches for the x-ray detection of ferromagnetic resonance are discussed.

  13. Magnetic resonance enterography in pediatric celiac disease.

    Science.gov (United States)

    Koc, Gonca; Doganay, Selim; Sevinc, Eylem; Deniz, Kemal; Chavhan, Govind; Gorkem, Sureyya B; Karacabey, Neslihan; Dogan, Mehmet S; Coskun, Abdulhakim; Aslan, Duran

    To assess if magnetic resonance enterography is capable of showing evidence/extent of disease in pediatric patients with biopsy-proven celiac disease by comparing with a control group, and to correlate the magnetic resonance enterography findings with anti-endomysial antibody level, which is an indicator of gluten-free dietary compliance. Thirty-one pediatric patients (mean age 11.7±3.1 years) with biopsy-proven celiac disease and 40 pediatric patients as a control group were recruited in the study. The magnetic resonance enterography images of both patients with celiac disease and those of the control group were evaluated by two pediatric radiologists in a blinded manner for the mucosal pattern, presence of wall thickening, luminal distention of the small bowel, and extra-intestinal findings. Patient charts were reviewed to note clinical features and laboratory findings. The histopathologic review of the duodenal biopsies was re-conducted. The mean duration of the disease was 5.6±1.8 years (range: 3-7.2 years). In 24 (77%) of the patients, anti-endomysial antibody levels were elevated (mean 119.2±66.6RU/mL). Magnetic resonance enterography revealed normal fold pattern in all the patients. Ten (32%) patients had enlarged mesenteric lymph nodes. Although a majority of the patients had elevated anti-endomysial antibody levels indicating poor dietary compliance, magnetic resonance enterography did not show any mucosal abnormality associated with the inability of magnetic resonance enterography to detect mild/early changes of celiac disease in children. Therefore, it may not be useful for the follow-up of pediatric celiac disease. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. A smart magnetic resonance contrast agent for selective copper sensing.

    Science.gov (United States)

    Que, Emily L; Chang, Christopher J

    2006-12-20

    We describe the synthesis and properties of Copper-Gad-1 (CG1), a new type of smart magnetic resonance (MR) sensor for selective detection of copper. CG1 is composed of a gadolinium contrast agent core tethered to copper-selective recognition motif. Cu2+-induced modulation of inner-sphere water access to the Gd3+ center provides a sensing mechanism for reporting Cu2+ levels by reading out changes in longitudinal proton relaxivity values. CG1 features good selectivity for Cu2+ over abundant biological cations and a 41% increase in relaxivity upon Cu2+ binding and is capable of detecting micromolar changes in Cu2+ concentrations in aqueous media.

  15. Quantitative magnetic resonance imaging of articular cartilage in osteoarthritis

    Directory of Open Access Journals (Sweden)

    G Blumenkrantz

    2007-05-01

    Full Text Available Magnetic resonance imaging of articular cartilage has recently been recognized as a tool for the characterization of cartilage morphology, biochemistry and function. In this paper advancements in cartilage imaging, computation of cartilage volume and thickness, and measurement of relaxation times (T2 and T1Ρ are presented. In addition, the delayed uptake of Gadolinium DTPA as a marker of proteoglycan depletion is also reviewed. The cross-sectional and longitudinal studies using these imaging techniques show promise for cartilage assessment and for the study of osteoarthritis.

  16. Magnetic resonance imaging of popliteal artery pathologies

    International Nuclear Information System (INIS)

    Holden, Andrew; Merrilees, Stephen; Mitchell, Nicola; Hill, Andrew

    2008-01-01

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions

  17. Magnetic resonance imaging of popliteal artery pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Holden, Andrew [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: andrewh@adhb.govt.nz; Merrilees, Stephen [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: smerrilees@adhb.govt.nz; Mitchell, Nicola [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: nmit010@ec.auckland.ac.nz; Hill, Andrew [Department of Vascular Surgery, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: ahill@adhb.govt.nz

    2008-07-15

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions.

  18. Magnetic elliptical polarization of Schumann resonances

    International Nuclear Information System (INIS)

    Sentman, D.D.

    1987-01-01

    Measurements of orthogonal, horizontal components of the magnetic field in the ELF range obtained during September 1985 show that the Schumann resonance eigenfrequencies determined separately for the north-south and east-west magnetic components differ by as much as 0.5 Hz, suggesting that the underlying magnetic signal is not linearly polarized at such times. The high degree of magnetic ellipticity found suggests that the side multiplets of the Schumann resonances corresponding to azimuthally inhomogeneous normal modes are strongly excited in the highly asymmetric earth-ionosphere cavity. The dominant sense of polarization over the measurement passband is found to be right-handed during local daylight hours, and to be left-handed during local nighttime hours. 16 references

  19. Proton magnetic resonance spectroscopy and perfusion magnetic resonance imaging in the evaluation of musculoskeletal tumors

    International Nuclear Information System (INIS)

    Costa, Flavia Martins; Setti, Marcela; Vianna, Evandro Miguelote; Domingues, Romulo Cortes; Meohas, Walter; Rezende, Jose Francisco; Gasparetto, Emerson Leandro

    2009-01-01

    Objective: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. Materials And Methods: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 135 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Time signal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. Results: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p < 0.0001). Statistically significant difference was observed in the slope (%/min) between benign (mean, 27.5%/min) and malignant (mean, 110.9%/min) lesions (p < 0.0001). Conclusion: The time-intensity curve and slope values using dynamic-enhanced perfusion magnetic resonance imaging in association with the presence of choline peak demonstrated by single voxel magnetic resonance spectroscopy study are useful in the differentiation between malignant and benign musculoskeletal tumors. (author)

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... ill effects on pregnant women or their unborn babies. However, because the unborn baby will be in a strong magnetic field, pregnant ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... epilepsy (seizure) hemorrhage in selected trauma patients certain chronic conditions, such as multiple sclerosis disorders of the ... a very small chance of irritation of your skin at the site of the IV tube insertion. Some ... Images related to Magnetic ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic ... patient to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine- ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  6. Nuclear magnetic resonance (NMR) tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.

    1984-01-01

    A brief survey of the working principle of the NMR technique in diagnostical medicine is given. Its clinical usefulness for locating tumors, diagnosing various other diseases, such as some mental illnesses and multiple sclerosis, and its possibilities for studying biochemical processes in vivo are mentioned. The price of NMR image scanners and the problems of the strong magnetic field around the machines are mentioned

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... MRI equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to see, hear and speak with your child at all times using a two-way intercom. Many MRI centers allow a parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... able to see, hear and speak with you at all times using a two-way intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and other cranial structures that are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and may require an injection of a ...

  12. Magnetic resonance investigation of magnetic-labeled baker's yeast cells

    International Nuclear Information System (INIS)

    Godoy Morais, J.P.M.; Azevedo, R.B.; Silva, L.P.; Lacava, Z.G.M.; Bao, S.N.; Silva, O.; Pelegrini, F.; Gansau, C.; Buske, N.; Safarik, I.; Safarikova, M.; Morais, P.C.

    2004-01-01

    In this study, the interaction of DMSA-coated magnetite nanoparticles (5 and 10 nm core-size) with Saccharomyces cerevisae was investigated using magnetic resonance (MR) and transmission electron microscopy (TEM). The TEM micrographs revealed magnetite nanoparticles attached externally to the cell wall. The MR data support the strong interaction among the nanoparticles supported by the cells. A remarkable shift in the resonance field was used as signature of particle attachment to the cell wall

  13. resonant inverter supplied interior permanent magnet (ipm)

    African Journals Online (AJOL)

    user

    [5] Zhenyue Hong, “DC-voltage link resonant inverters”, Department of Electrical and. Electronic Engineering University of. Canterbury, New Zealand. [6] Kalyan Kumar Halder, Naruttam Kumar Roy and B.C. Ghosh, “Position Sensorless. Control for an Interior Permanent Magnet. Synchronous Motor SVM Drive with ANN.

  14. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  15. Pharyngeal branchial cyst: magnetic resonance findings

    Energy Technology Data Exchange (ETDEWEB)

    Cerezal, L.; Canga, A. [Department of Radiology of the ' Santa Cruz' Hospital Liencres, Cantabria (Spain); Morales, C. [Department of Otorhinolaryngology of the ' Sierrallana' Hospital Torrelavega, Cantabria (Spain); Abascal, F.; Usamentiaga, E.; Bustamante, M. [Department of Radiology of the University Hospital ' Marques de Valdecilla' , Av. de Valdecilla s/n Santander 39008 (Spain); Olcinas, O. [Department of Pathology of the University Hospital ' Marques de Valdecilla' , Av. de Valdecilla s/n Santander 39008 (Spain)

    1998-11-01

    An unusual case of pharyngeal cyst in a 25-year-old man studied by Magnetic Resonance (MR) is described. Anatomic location and pathological findings indicated the second branchial pouch origin. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. Pharyngeal branchial cyst: magnetic resonance findings

    International Nuclear Information System (INIS)

    Cerezal, L.; Canga, A.; Morales, C.; Abascal, F.; Usamentiaga, E.; Bustamante, M.; Olcinas, O.

    1998-01-01

    An unusual case of pharyngeal cyst in a 25-year-old man studied by Magnetic Resonance (MR) is described. Anatomic location and pathological findings indicated the second branchial pouch origin. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  17. Numerical methods in electron magnetic resonance

    International Nuclear Information System (INIS)

    Soernes, A.R.

    1998-01-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system

  18. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  19. Magnetic resonance angiography in meningovascular syphilis

    Energy Technology Data Exchange (ETDEWEB)

    Gallego, J [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Soriano, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Zubieta, J L [Servicio de Neuroradiologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Delgado, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Villanueva, J A [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain)

    1994-04-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  20. Cryogenic Preamplifiers for Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Johansen, Daniel H.; Sanchez-Heredia, Juan D.; Petersen, Jan R.

    2018-01-01

    Pursuing the ultimate limit of detection in magnetic resonance imaging (MRI) requires cryogenics to decrease the thermal noise of the electronic circuits. As cryogenic coils for MRI are slowly emerging cryogenic preamplifiers are required to fully exploit their potential. A cryogenic preamplifier...

  1. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  2. Magnetic resonance imaging of xanthomatous meningioma

    International Nuclear Information System (INIS)

    Katayama, Y.; Tsubokawa, T.; Tanaka, A.; Koshinaga, M.; Nemoto, N.

    1993-01-01

    A case of meningioma with extensive xanthomatous metaplasia occurring in the left frontal convexity of a 37-year-old woman is reported. The tumour was demonstrated as a hypodense mass with minimal enhancement on CT. Our findings suggest that magnetic resonance imaging may provide a clue to the diagnosis of meningiomas with extensive xanthomatous metaplasia when CT is less specific. (orig.)

  3. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  4. Vascular anatomy in angiography for magnetic resonance

    International Nuclear Information System (INIS)

    Charry Lopez, Marco Luciano; Rivera Gomez, Juan Enrique

    1998-01-01

    A review of basic anatomical concepts and main variants, as well as some anatomical anomalies of the central nervous system vascularity, these concepts are considered essential for the interpretation of magnetic resonance angiography with time-of-flight (TOF) and phase-contrast (PC) methods

  5. Magnetic resonance imaging in obstetric diagnosis.

    Science.gov (United States)

    Weinreb, J C; Lowe, T W; Santos-Ramos, R; Cunningham, F G; Parkey, R

    1985-01-01

    Five patients with abnormal pregnancies were examined with ultrasound (US) and magnetic resonance imaging (MR). Three had a malformed fetus, 1 had a molar pregnancy, and 1 had an ovarian mass. Both maternal and fetal structures were clearly shown, although fetal motion may have resulted in image degradation in some cases. The authors suggest that MR may be useful in obstetric diagnosis.

  6. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  7. Magnetic resonance imaging in sudden deafness

    International Nuclear Information System (INIS)

    Ramos, Hugo Valter Lisboa; Barros, Flavia Alencar; Penido, Norma de Oliveira; Souza, Ana Claudia Valerio de; Yamaoka, Wellington Yugo; Yamashita, Helio

    2005-01-01

    The etiology of sudden deafness can remain undetermined despite extensive investigation. This study addresses the value of magnetic resonance imaging in the analysis of sudden deafness patients.Study Design: transversal cohort.Material And Method: In a prospective study, 49 patients attended at otolaryngology emergency room of Federal University of Sao Paulo - Escola Paulista de Medicina, from April 2001 to May 2003, were submitted to magnetic resonance imaging.Results: Magnetic Resonance abnormalities were seen in 23 (46.9%) patients and revealed two tumors suggestive of meningioma, three vestibular schwannomas, thirteen microangiopathic changes of the brain and five (21.7%) pathological conditions of the labyrinth.Conclusion: Sudden deafness should be approached as a symptom common to different diseases. The presence of cerebellopontine angle tumors in 10.2% of our cases, among other treatable causes, justifies the recommendation of gadolinium-enhanced magnetic resonance use, not only to study the auditory peripheral pathway, but to study the whole auditory pathway including the brain. (author)

  8. Magnetic resonance studies of solid polymers

    International Nuclear Information System (INIS)

    Lenk, R.

    1969-01-01

    This paper is a review of the application of nuclear magnetic resonance (NMR) to solid polymers. In the first, theoretical part, the elements of the theory of NMR, which are necessary for the study of the properties of solid polymers are discussed: the moments method, nuclear relaxation and the distribution of correlation times. In the second part the experimental results are presented. (author) [fr

  9. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  10. Magnetic resonance imaging of the knee

    International Nuclear Information System (INIS)

    Nederveen, D.; Bakker, C.J.G.; Scholten, F.G.; Feldberg, N.A.M.; Postma, J.H.; Vis, H. van der

    1989-01-01

    Sixteen patients suspected of having meniscal lesions, were examined bt magnetic resonance (MR) and arthroscopy, MR and arthroscopy corelate well for meniscal and cruciate ligament lesions. Damage of the articular cartilage was, however, not detected by MR (author). 15 refs.; 4 figs.; 1 tab

  11. Intralabyrinthine schwannoma shown by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Saeed, S.R.; Birzgalis, A.R.; Ramsden, R.T.

    1994-01-01

    Intralabyrinthine schwannomas are rare benign tumours which present with progressive or fluctuant audiovestibular symptoms and may mimic Menieres disease. The size and position of these lesions make preoperative diagnosis unusual and most are discovered incidentally at labyrinthectomy. A case is reported which was diagnosed on magnetic resonance imaging and confirmed at surgery. (orig.)

  12. Magnetic resonance imaging of semicircular canals.

    Science.gov (United States)

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290

  13. Quantitative dosing by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Solomon, I.

    1958-01-01

    The measurement of the absolute concentration of a heavy water reference containing approximately 99.8 per cent of D 2 O has been performed, by an original magnetic resonance method ('Adiabatic fast passage method') with a precision of 5.10 -5 on the D 2 O concentration. (author) [fr

  14. Magnetic resonance angiography in meningovascular syphilis

    International Nuclear Information System (INIS)

    Gallego, J.; Soriano, G.; Zubieta, J.L.; Delgado, G.; Villanueva, J.A.

    1994-01-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  15. Nonlinear nuclear magnetic resonance in ferromagnets

    International Nuclear Information System (INIS)

    Nurgaliev, T.

    1988-01-01

    The properties of nonlinear nuclear magnetic resonance (NMR) have been studied theoretically by taking into account the interaction between NMR and FMR in the ferromagnets. The Landau-Lifshitz-Bloch equations, describing the electron and nuclear magnetization behaviour in ferromagnets are presented in an integral form for a weakly excited electronic system. The stationary solution of these equations has been analysed in the case of equal NMR and FMR frequencies: the criteria for the appearance of two stable dynamic states is found and the high-frequency magnetic susceptibility for these systems is investigated. 2 figs., 8 refs

  16. Interaction of magnetic resonators studied by the magnetic field enhancement

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available It is the first time that the magnetic field enhancement (MFE is used to study the interaction of magnetic resonators (MRs, which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  17. Magnetic resonance study of maghemite-based magnetic fluid

    International Nuclear Information System (INIS)

    Figueiredo, L.C.; Lacava, B.M.; Skeff Neto, K.; Pelegrini, F.; Morais, P.C.

    2008-01-01

    This study reports on the magnetic resonance (MR) data (X-band experiment) of 10.2 nm average diameter maghemite nanoparticle in the temperature range of 100-230 K. Maghemite nanoparticles were suspended as low-pH ionic magnetic fluid containing 2.3x10 17 particles/cm 3 . The temperature dependence of both resonance linewidth and resonance field of the zero-field-cooled sample as well as the resonance field of the field-cooled sample (angular variation experiment) was analyzed using well-established methodology. Information regarding particle size, particle clusterization and surface magnetic anisotropy were obtained from the analysis of the MR data. The number of magnetic sites per particle from the MR data is in excellent agreement with the number provided by the transmission electron microscopy (TEM) data. The demagnetizing field value obtained from the MR data indicates cluster of particles containing on average 1.42 particles. The MR angular variation data suggest that magnetoelastic effect accounts for the non-linearity observed for the surface component of the magnetic anisotropy

  18. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  19. Magnetic resonance imaging of infectious myositis

    International Nuclear Information System (INIS)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha

    1998-01-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  20. Magnetic resonance: safety measures and biological effects

    International Nuclear Information System (INIS)

    Gordillo, I.; Lafuente, J.; Fernandez, C.; Barbero, M.J.; Cascon, E.

    1997-01-01

    The biological effects of electromagnetic fields is currently a subject of great controversy. For this reason, magnetic resonance imaging (MRI) and spectroscopy are constantly under investigation. The source of the risk in MRI is associated with the three types of electromagnetic radiation to which the patient is exposed: the static magnetic field, variable (gradient) magnetic fields and radiofrequency fields. Each is capable of producing significant biological effects when employed at sufficient intensity. Patients exposed to risk sources are those situated within the lines of force of the magnetic field, ellipsoid lines that are arranged around the magnet, representing the strength of the surrounding field. To date, at the intensity normally utilized in MRI(<2T) and respecting the field limit recommendations established by the US Food and Drug Administration (FDA) for clinical use of this technique no adverse secondary biological effects have been reported. The known biological effects and other possible secondary effects are reviewed, and the recommended safety measures are discussed. (Author)

  1. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki

    1991-01-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author)

  2. The market for magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Carlson, L.

    1990-01-01

    The medical market is, at present, the most dominant market for low T c superconductors. Indeed, without magnetic resonance imaging (MRI), there would hardly be a low T c superconductor market at all. According to the author, any development that can expand the medical market for MRI machines would be a welcome one. This paper reports how the recent advances in magnetic resonance spectroscopy (MRS) are such a development. While the principle of MRS has bee around as long as MRI, only recently have advances in technique, computer programming and magnet technology allowed MRS to advance to a point where it may become an important technology-one that could increase the medical market for superconductors. The author discussed how MRS can be used to analyze oil core samples for their oil content, oil/water ratios, how the oil is bound and how to extract it

  3. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  4. Transcranial magnetic stimulation assisted by neuronavigation of magnetic resonance images

    Science.gov (United States)

    Viesca, N. Angeline; Alcauter, S. Sarael; Barrios, A. Fernando; González, O. Jorge J.; Márquez, F. Jorge A.

    2012-10-01

    Technological advance has improved the way scientists and doctors can learn about the brain and treat different disorders. A non-invasive method used for this is Transcranial Magnetic Stimulation (TMS) based on neuron excitation by electromagnetic induction. Combining this method with functional Magnetic Resonance Images (fMRI), it is intended to improve the localization technique of cortical brain structures by designing an extracranial localization system, based on Alcauter et al. work.

  5. Transformation of QSPA plasma streams in longitudinal magnetic field

    International Nuclear Information System (INIS)

    Makhlaj, V.A.; Bandura, A.N.; Chebotarev, V.V.; Kulik, N.V.; Wuerz, H.

    2002-01-01

    The main aim of this work is analysis of efficiency of QSPA powerful plasma streams transportation in longitudinal magnetic field in dependence on operational mode of accelerator and plasma stream parameters

  6. Magnetic resonance imaging in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.; Paprzycki, W.

    1993-01-01

    In the paper authors describe fundamental physical properties of a phenomenon of the radio-frequency excitation and relaxation of nuclei ordered in a strong magnetic field and the usefulness of MRI in medical diagnostic procedures. Basic interpretations principles of MR imaging due to signal intensity differences between organs and tissues in T 1 - and T 2 - weighted sequences and proton density are presented. Both, literature review and experience of authors suggest application of MRI in otolaryngology, it is illustrated by a lot of examples. The MR imaging studies were compared with results obtained from CT in otolaryngology field. (author)

  7. Magnetic Resonance Imaging (MRI): Lumbar Spine (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Lumbar Spine KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Lumbar Spine What's in this article? ...

  8. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  9. Musculoskeletal applications of magnetic resonance imaging: Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Harms, S.E.; Fisher, C.F.; Fulmer, J.M.

    1989-01-01

    Magnetic resonance imaging provides superior contrast, resolution, and multiplanar imaging capability, allowing excellent definition of soft-tissue and bone marrow abnormalities. For these reasons, magnetic resonance imaging has become a major diagnostic imaging method for the evaluation of many musculoskeletal disorders. The applications of magnetic resonance imaging for musculoskeletal diagnosis are summarized and examples of common clinical situations are given. General guidelines are suggested for the musculoskeletal applications of magnetic resonance imaging

  10. Nuclear magnetic resonance (NMR): principles and applications

    International Nuclear Information System (INIS)

    Quibilan, E.I.

    The basis for the phenomenon of nuclear magnetic resonance (NMR) is the ability of certain nuclei possessing both intrinsic angular momentum or ''spin'' I and magnetic moment to absorb electromagnetic energy in the radio frequency range. In principle, there are approximately 200 nuclei which may be investigated using the NMR technique. The NMR spectrum consists of intensity peaks along an axis calibrated in terms of the steady magnetic field or the frequency of the radiofrequency electromagnetic radiation. Analysis of the number, spacing, position and intensity of the lines in an NMR spectrum consists of intensity peaks along an axis calibrated in terms of the steady magnetic field or the frequency of the radiofrequency electromagnetic radiation. Analysis of the number, spacing, position and intensity of the lines in an NMR spectrum provides a variety of qualitative and quantitative analytical applications. The most obvious applications consist of the measurements of nuclear properties, such as spin number and nuclear magnetic moment. In liquids, the fine structure of resonance spectra provides a tool for chemical identification and molecular structure analysis. Other applications include the measurements of self-diffusion coefficients, magnetic fields and field homogeneity, inter-nuclear distances, and, in some cases, the water content of biological materials. (author)

  11. Physics of Magnetic Resonance. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hee Kwon [Hospital of the University of Pennsylvania, Philadelphia (United States)

    2014-09-15

    The discovery of nuclear magnetic resonance (NMR), a property of nuclei in a magnetic field where they are able to absorb applied radiofrequency (RF) energy and subsequently release it at a specific frequency, goes back many decades to the early 1900s. Physicist Isidor I. Rabi, fascinated by the work of Otto Stern and Walther Gerlach which demonstrated that particles have intrinsic quantum properties, delved into the magnetic properties of nuclei, and in 1938 Rabi discovered the phenomenon of NMR. Several years later, in 1946, Felix Bloch and Edward Purcell refined the methods and successfully measured the NMR signal from liquids and solids. For their discoveries, Rabi received the Nobel Prize for physics in 1944 and Bloch and Purcell in 1952. While Rabi, Bloch, Purcell and other physicists working in this field had laid the foundations, a major discovery that transformed the NMR phenomenon for imaging was not made until 1973, when Paul Lauterbur developed a method for spatially encoding the NMR signal by utilizing linear magnetic field gradients. About the same time, Peter Mansfield had also discovered a means of determining the spatial structure of solids by introducing a linear gradient across the object. The idea of applying magnetic field gradients to induce spatially varying resonance frequencies to resolve the spatial distribution of magnetization was a major milestone and the beginning of magnetic resonance imaging (MRI). For their work, Lauterbur and Mansfield were awarded the Nobel Prize for medicine in 2003. Since its discovery, MRI has quickly become one of the most important medical imaging devices available to physicians today. Unlike other imaging modalities, such as X ray and computed tomography, MRI does not involve ionizing radiation. MRI also offers superior soft tissue contrast that is not possible with other imaging modalities. Furthermore, in MRI, the desired level of image contrast among different tissues can often be precisely controlled

  12. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Science.gov (United States)

    2011-09-20

    ...] Magnetic Resonance Imaging Safety; Public Workshop AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public workshop entitled: ``Magnetic Resonance Imaging (MRI) Safety Public Workshop.'' The purpose of the public workshop is to discuss factors affecting the safe use of magnetic resonance imaging...

  13. Functional magnetic resonance imaging of the primary motor cortex ...

    Indian Academy of Sciences (India)

    Unknown

    Abbreviations used: BOLD, Blood oxygenation level dependent; CBF, cerebral blood flow; fMRI, functional magnetic resonance imaging; EPI, eco-planar imaging; FOV, field of view; MRI, Magnetic resonance imaging; MRS, magnetic resonance spectroscopy;. PET, position emission tomography; rCBF, regional cerebral ...

  14. Nuclear magnetic resonance in ferromagnetic terbium metal

    International Nuclear Information System (INIS)

    Cha, C.L.T.

    1974-01-01

    The magnetic properties of terbium were studied by the method of zero field nuclear magnetic resonance at 1.5 to 4 and 85 to 160 0 K. Two unconventional experimental techniques have been employed: the swept frequency and the swept temperature technique. Near 4 0 K, triplet resonance line structures were found and interpreted in terms of the magnetic domain and wall structures of ferromagnetic terbium. In the higher temperature range, temperature dependence of the resonance frequency and the quadrupole splitting were measured. The former provides a measurement of the temperature dependence of the magnetization M, and it agrees with bulk M measurements as well as the latest spin wave theory of M(T) (Brooks 1968). The latter agrees well with a calculation using a very general single ion density matrix for collective excitations (Callen and Shtrikman 1965). In addition, the small temperature-independent contribution to the electric field gradient at the nucleus due to the lattice and conduction electrons was untangled from the P(T) data. Also an anomalous and unexplained relaxation phenomenon was also observed

  15. [Magnetic resonance compatibility research for coronary mental stents].

    Science.gov (United States)

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  16. A hyperpolarized equilibrium for magnetic resonance.

    Science.gov (United States)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B; Mewis, Ryan E; Highton, Louise A R; Kenny, Stephen M; Green, Gary G R; Leibfritz, Dieter; Korvink, Jan G; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all ¹H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10⁻³ Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  17. Nuclear magnetic resonance imaging in pharmaceutical research

    International Nuclear Information System (INIS)

    Sarkar, S.K.

    1991-01-01

    Nuclear magnetic resonance imaging has important applications in pharmaceutical research since it allows specific tissue and disease characterization in animal models noninvasively with excellent anatomical resolution and therefore provides improved ability to monitor the efficacy of novel drugs. The utility of NMR imaging in renal studies to monitor the mechanism of drug action and renal function in rats is described. The extension of the resolution of an NMR image to microscopic domain at higher magnetic field strengths and the utility of NMR microimaging in cerebrovascular and tumour metastasis studies in mice are discussed. (author). 40 refs., 14 figs

  18. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Young, I.R.

    1983-01-01

    In a method of investigating the distribution of a quantity in a chosen region of a body (E) by nuclear magnetic resonance techniques movement of the body during the investigation is monitored by probes (A, B C) (C extends orthogonally to A and B) attached to the body and responsive to magnetic fields applied to the body during the investigation. An apparatus for carrying out the method is also described. If movement is detected, due compensation may be made during processing of the collected data, or the latter may be re-ascertained after appropriate adjustment e.g. a change in the RF excitation frequency. (author)

  19. Proton magnetic resonance spectroscopy in the fetus.

    Science.gov (United States)

    Story, Lisa; Damodaram, Mellisa S; Allsop, Joanna M; McGuinness, Amy; Wylezinska, Marzena; Kumar, Sailesh; Rutherford, Mary A

    2011-09-01

    Magnetic Resonance Imaging (MRI) has become an established technique in fetal medicine, providing complementary information to ultrasound in studies of the brain. MRI can provide detailed structural information irrespective of the position of the fetal head or maternal habitus. Proton Magnetic Resonance Spectroscopy ((1)HMRS) is based on the same physical principles as MRI but data are collected as a spectrum, allowing the biochemical and metabolic status of in vivo tissue to be studied in a non-invasive manner. (1)HMRS has been used to assess metabolic function in the neonatal brain but fetal studies have been limited, primarily due to fetal motion. This review will assess the technique and findings from fetal studies to date. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Magnetic resonance studies of intercalation compounds

    International Nuclear Information System (INIS)

    Miller, G.R.

    1990-01-01

    During the last three or four years, nearly tow hundred papers have been published that used NMR or ESR spectroscopy to study compounds formed by the intercalation of molecules or ions into the van der Waals gap of a layered hast compound. The host lattices have ranged from the simple, such as graphite, to the complex, such as clay. In many cases, magnetic resonance techniques now enable one to obtain quite detailed information on even fairly complex intercalated species, on the nature of the changes in the host lattice accompanying intercalation, and on the nature of the interactions between the intercalant species and the host lattice. Magnetic resonance is used in conunction with many other techniques to obtain a fuller picture of these interesting systems, but this review will limit its focus to the use of NMR and ESR techniques. (author). 51 refs

  1. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus)......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.......Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  2. Magnetic resonance imaging findings in tuberculous meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Pui, M.H.; Memon, W.A. [Aga Khan Univ. Hospital, Dept. of Radiology, Karachi (Pakistan)

    2001-02-01

    To evaluate the efficacy of magnetic resonance imaging (MRI) for distinguishing tuberculosis from other types of meningoencephalitis. MRIs of 100 patients with tuberculous (50), pyogenic (33), viral (14), or fungal (3) meningoencephalitis were analyzed independently by 2 radiologists. Number, size, location, signal characteristics, surrounding edema, and contrast enhancement pattern of nodular lesions; location and pattern of meningeal enhancement; extent of infarct or encephalitis and hydrocephalus were evaluated. Contrast-enhancing nodular lesions were detected in patients with tuberculous (43 of 50 patients), pyogenic (9 of 33), and fungal (3 of 3) infections. No nodules were detected in patients with viral meningoencephalitis. Using the criteria of 1 or more solid rim or homogeneously enhancing nodules smaller than 2 cm, the sensitivity, specificity and accuracy for diagnosing tuberculous meningitis were 86.0%, 90.0% and 88.0%, respectively. Magnetic resonance imaging is useful in distinguishing tuberculous from pyogenic, viral and fungal meningoencephalitis. (author)

  3. Magnetic resonance imaging of flow and mass transfer in electrohydrodynamic liquid bridges

    NARCIS (Netherlands)

    Wexler, Adam D.; Drusová, Sandra; Fuchs, Elmar C.; Woisetschläger, Jakob; Reiter, Gert; Fuchsjäger, Michael; Reiter, Ursula

    2017-01-01

    Abstract: Here, we report on the feasibility and use of magnetic resonance imaging-based methods to the study of electrohydrodynamic (EHD) liquid bridges. High-speed tomographic recordings through the longitudinal axis of water bridges were used to characterize the mass transfer dynamics, mixing,

  4. Draws on a relativistic pinch with a longitudinal magnetic field

    International Nuclear Information System (INIS)

    Trubnikov, B.A.

    1991-01-01

    The problems of draws on a relativistic pinch with longitudinal magnetic field are discussed. The absence of collisions promoting the energy exchange between different degrees of particle freedom is assumed. The calculations are conducted using the ideal relativistic anisotropic magnetic hydrodynamics equations. The spectrum of particles accelerated in the draws, is determined

  5. Two-dimensional nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Bax, A.; Lerner, L.

    1986-01-01

    Great spectral simplification can be obtained by spreading the conventional one-dimensional nuclear magnetic resonance (NMR) spectrum in two independent frequency dimensions. This so-called two-dimensional NMR spectroscopy removes spectral overlap, facilitates spectral assignment, and provides a wealth of additional information. For example, conformational information related to interproton distances is available from resonance intensities in certain types of two-dimensional experiments. Another method generates 1 H NMR spectra of a preselected fragment of the molecule, suppressing resonances from other regions and greatly simplifying spectral appearance. Two-dimensional NMR spectroscopy can also be applied to the study of 13 C and 15 N, not only providing valuable connectivity information but also improving sensitivity of 13 C and 15 N detection by up to two orders of magnitude. 45 references, 10 figures

  6. Nuclear magnetic resonance - from molecules to man

    OpenAIRE

    Wüthrich, Kurt

    2017-01-01

    Initial observations of the physical phenomenon of nuclear magnetic resonance (NMR) date back to the late 1940s. In the following two decades high-resolution NMR in solution became an indispensible analytical tool in chemistry, and solid state NMR had an increasingly important role in physics. Some of the potentialities of the method for investigations of complex biological systems had also long been anticipated, and initial experiments with biological specimens were described already 30 year...

  7. OPTIMAL EXPERIMENT DESIGN FOR MAGNETIC RESONANCE FINGERPRINTING

    OpenAIRE

    Zhao, Bo; Haldar, Justin P.; Setsompop, Kawin; Wald, Lawrence L.

    2016-01-01

    Magnetic resonance (MR) fingerprinting is an emerging quantitative MR imaging technique that simultaneously acquires multiple tissue parameters in an efficient experiment. In this work, we present an estimation-theoretic framework to evaluate and design MR fingerprinting experiments. More specifically, we derive the Cram��r-Rao bound (CRB), a lower bound on the covariance of any unbiased estimator, to characterize parameter estimation for MR fingerprinting. We then formulate an optimal experi...

  8. Magnetic resonance in multiple sclerose twins

    International Nuclear Information System (INIS)

    Polman, C.H.; UitdeHaag, B.M.J.; Koetsier, C.J.; Valk, J.; Lucas, C.J.

    1989-01-01

    Magnetic resonance imaging (MR) examinations were performed in a series of 7 twin sets (4 monozygotic and 3 dizygotic) and one triplet set who were clinically discordant for multiple sclerosis (MS). MRI abnormalities were detected in a number of the unaffected members of the nonzygotic twin pairs. The authors discuss the possible implications of their findings for the present view on the aetiology of MS. (author). 3 refs.; 1 fig.; 1 tab

  9. Basic principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Valk, J.; MacLean, C.; Algra, P.R.

    1985-01-01

    The intent of this book is to help clinicians understand the basic physical principles of magnetic resonance (MR) imaging. The book consists of the following: a discussion of elementary considerations; pulse sequencing; localization of MR signals in space; MR equipment; MR contrast agents; clinical applications; MR spectroscopy; and biological effects of MR imaging; a set of appendixes; and a bibliography. Illustrations and images are included

  10. BOLD magnetic resonance imaging in nephrology

    OpenAIRE

    Hall ME; Jordan JH; Juncos LA; Hundley WG; Hall JE

    2018-01-01

    Michael E Hall,1,2 Jennifer H Jordan,3 Luis A Juncos,1,2 W Gregory Hundley,3 John E Hall2 1Department of Medicine, University of Mississippi Medical Center, Jackson, MS, USA; 2Department of Physiology and Biophysics, University of Mississippi Medical Center, Jackson, MS, USA; 3Department of Internal Medicine, Section on Cardiovascular Medicine, Wake Forest University School of Medicine, Winston-Salem, NC, USA Abstract: Magnetic resonance (MR) imaging, a non-invasive modality that provides ana...

  11. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  12. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup....

  13. Magnetic resonance imaging in MELAS syndrome

    International Nuclear Information System (INIS)

    Rosen, L.; Phillips, S.; Enzmann, D.

    1990-01-01

    MELAS syndrome is a distinct clinical entity belonging to a group of mitochondrial encephalomyopathies characterized by the tetrad of myopathy, encephalopathy, lactic acidosis, and stroke-like episodes. Computed tomography (CT) and magnetic resonance (MR) findings are reviewed in a patient with MELAS. Serial CT studies demonstrated multiple 'migrating' infarcts in various stages of evolution involving primarily the posterior temporal and occipital regions. MR was more sensitive than CT in demonstrating the number and extent of cortical lesions in this disease entity. (orig.)

  14. Effect of an additional magnetic field on Hanle-type absorption resonances

    International Nuclear Information System (INIS)

    Singh Grewal, Raghwinder; Pattabiraman, M

    2014-01-01

    We computationally compare Hanle-type resonances for a F g =1→F e =0 transition of the 87 RbD 2 line for magnetic field scans parallel (longitudinal scan) and perpendicular (transverse scan) to the direction of propagation of the optical field in the presence of an additional transverse magnetic field (TMF). For a linearly polarized light, the coherent population trapping (CPT) resonances split at line centre and are identical for both longitudinal and transverse scans. When the probe beam ellipticity is varied, the effect of the TMF is found to be opposite for longitudinal and transverse scans. For a longitudinal scan, the splitting observed in the CPT resonance evolves into an enhanced absorption resonance with an increase in ellipticity. For a transverse scan, the splitting vanishes at higher ellipticities. This can be understood in terms of population redistribution in the ground state sublevels and near-neighbor ground state coherences created by the TMF. We also show that the enhanced absorption signal that splits the CPT resonance strongly depends on transit time, and the CPT resonance strength depends on the excited state dephasing rate. (paper)

  15. Cardiac magnetic resonance imaging in clinical practice

    Directory of Open Access Journals (Sweden)

    Adriana Dias Barranhas

    2014-01-01

    Full Text Available Objective To evaluate and describe indications, mainly diagnoses and cardiac magnetic resonance imaging findings observed in clinical practice. Materials and Methods Retrospective and descriptive study of cardiac magnetic resonance performed at a private hospital and clinic in the city of Niterói, RJ, Brazil, in the period from May 2007 to April 2011. Results The sample included a total of 1000 studies performed in patients with a mean age of 53.7 ± 16.2 years and predominance for male gender (57.2%. The majority of indications were related to assessment of myocardial perfusion at rest and under pharmacological stress (507/1000; 51%, with positive results in 36.2% of them. Suspected myocarditis was the second most frequent indication (140/1000; 14%, with positive results in 63.4% of cases. These two indications were followed by study of arrhythmias (116/1000; 12%, myocardial viability (69/1000; 7% and evaluation of cardiomyopathies (47/1000; 5%. In a subanalysis, it was possible to identify that most patients were assessed on an outpatient basis (58.42%. Conclusion Cardiac magnetic resonance has been routinely performed in clinical practice, either on an outpatient or emergency/inpatient basis, and myocardial ischemia represented the main indication, followed by investigation of myocarditis, arrhythmogenic right ventricular dysplasia and myocardial viability.

  16. Image production by magnetic resonance: transparency via the atom

    International Nuclear Information System (INIS)

    Kanel, A.

    1984-01-01

    The author gives a general description of the nuclear magnetic resonance technique to study the human body. The use of superconducting magnets to generate the required magnetic field is discussed. (G.T.H.)

  17. Magnetically coupled Fano resonance of dielectric pentamer oligomer

    International Nuclear Information System (INIS)

    Zhang, Fuli; Li, Chang; He, Xuan; Chen, Lei; Fan, Yuancheng; Zhao, Qian; Zhang, Weihong; Zhou, Ji

    2017-01-01

    We present magnetically induced Fano resonance inside a dielectric metamaterial pentamer composed of ceramic bricks. Unlike previous reports where different sizes of dielectric resonators were essential to produce Fano resonance, under external magnetic field excitation, central and outer dielectric bricks with identical sizes exhibit in-phase and out-of-phase magnetic Mie oscillations. An asymmetric line shape of Fano resonance along with enhanced group delay is observed due to the interference between the magnetic resonance of the central brick and the symmetric magnetic resonance of outer bricks. Besides, Fano resonance blueshifts with the increasing resonance of the smaller central brick. The thermal-dependent permittivity of ceramics allows Fano resonance to be reversibly tuned by 300 MHz when temperature varies by 60 °C. (paper)

  18. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...

  19. Realizing a Circuit Analog of an Optomechanical System with Longitudinally Coupled Superconducting Resonators

    OpenAIRE

    Eichler, C.; Petta, J. R.

    2017-01-01

    We realize a superconducting circuit analog of the generic cavity-optomechanical Hamiltonian by longitudinally coupling two superconducting resonators, which are an order of magnitude different in frequency. We achieve longitudinal coupling by embedding a superconducting quantum interference device (SQUID) into a high frequency resonator, making its resonance frequency depend on the zero point current fluctuations of a nearby low frequency LC-resonator. By employing sideband drive fields we e...

  20. Magnetic resonance imaging of tablet dissolution.

    Science.gov (United States)

    Nott, Kevin P

    2010-01-01

    Magnetic resonance imaging (MRI) is the technique of choice for measuring hydration, and its effects, during dissolution of tablets since it non-invasively maps (1)H nuclei associated with 'mobile' water. Although most studies have used MRI systems with high-field superconducting magnets, low-field laboratory-based instruments based on permanent magnet technology are being developed that provide key data for the formulation scientist. Incorporation of dissolution hardware, in particular the United States Pharmacopeia (USP) apparatus 4 flow-through cell, allows measurements under controlled conditions for comparison against other dissolution methods. Furthermore, simultaneous image acquisition and measurement of drug concentration allow direct comparison of the drug release throughout the hydration process. The combination of low-field MRI with USP-4 apparatus provides another tool to aid tablet formulation. Copyright 2009 Elsevier B.V. All rights reserved.

  1. Nuclear magnetic resonance studies of lipoproteins

    International Nuclear Information System (INIS)

    Hamilton, J.A.; Morrisett, J.D.

    1986-01-01

    Several nuclei in lipoproteins are magnetically active and are thus potential NMR probes of lipoprotein structure. Table I lists the magnetic isotopes preset in the covalent structures of the molecular constituents of lipoproteins: lipids, proteins, and carbohydrates. Every type of nucleus that is part of the endogenous structure of these molecules has at least one magnetic isotope. Each magnetic nucleus represents an intrinsic and completely nonperturbing probe (when at the natural abundance level) of local molecular motion and magnetic environment. The NMR experiment itself is also nonperturbing and nondestructive. Table I also lists for each nucleus its nuclear spin, its natural isotopic abundance, its sensitivity, and its resonance frequency at two commonly employed magnetic in the low field range (21.14 kG or 2.11 Tesla) and the other in the high field range (47.0 kG or 4.70 Tesla). Of the nuclei listed in Table I, /sup 1/H, /sup 13/C, and /sup 31/P have been the primary ones studied in lipoproteins. The general advantages and disadvantages afforded by these and other nuclei as probes of lipoprotein structure are discussed. /sup 13/C NMR spectroscopy, the method which has had the most extensive application (and probably has the greatest future potential) to lipoproteins, is treated in greatest detail, but many of the principles described apply to other nuclei as well

  2. Magnetic resonance phenomena in dynamics of relativistic particles

    International Nuclear Information System (INIS)

    Ternov, I.M.; Bordovitsyn, V.A.

    1987-01-01

    A relativistic generalization of Rabi's formula for magnetic resonance is given. On this basis, we consider fast and slow passage through resonance. We define a magnetic resonance exterior field as usual, using unit vectors of a Cartesian coordinate system, a homogeneous magnetic field, and the amplitude of a rotating magnetic field. For the description of spin dynamics we use the Bargmann-Michel-Telegdi equation

  3. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    Science.gov (United States)

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. Nuclear resonance apparatus including means for rotating a magnetic field

    International Nuclear Information System (INIS)

    Sugimoto, H.

    1983-01-01

    A nuclear magnetic resonance apparatus including magnet apparatus for generating a homogeneous static magnetic field between its magnetic poles, shims of a magnetic substance mounted on the magnetic poles to apply a first gradient magnetic field intensity distribution in a direction orthogonal as to the direction of line of magnetic force of the static magnetic field, gradient magnetic field generating electromagnetic apparatus for generating a second gradient magnetic field having a gradient magnetic field intensity distribution in superimposition with the static magnetic field and for changing the magnetic field gradient of the first gradient magnetic field, an oscillator for generating an oscillating output having a frequency corresponding to the nuclear magnetic resonance condition of an atomic nucleus to be measured, a coil wound around a body to be examined for applying the output of said oscillator as electromagnetic waves upon the body, a receiver for detecting the nuclear magnetic resonance signals received by the coil, a gradient magnetic field controller making a magnetic field line equivalent to the combined gradient magnetic fields and for rotating the line along the section of the body to be examined by controlling said gradient magnetic field generating electromagnetic apparatus and devices for recording the nuclear magnetic resonance signals, for reconstructing the concentration distribution of the specific atomic nuclei in the section of the body, and a display unit for depicting the result of reconstruction

  5. Dynamics of a longitudinal current during a magnetic storm

    International Nuclear Information System (INIS)

    Dolginov, S.Sh.; Zhuzgov, L.N.; Kosacheva, V.P.; Strunnikova, L.N.; Tyurmina, L.O.; Sharova, V.A.; Shkol'nikova, S.I.

    1984-01-01

    Results, investigating a spatial distribution and the structure of longitudinal currents during a magnetic storm at 18-19.09.81, are presented. It is shown that during the main phase of the storm the large-scale current system expands to the equator, and current density increases. Inside the current layer and to the pole of it there appears intensive small scale longitudinal l currents. During magnetic storm restopation phase the current system segregates into several pairs of opposite directed currents. During further decreasing of geomagnetic activity the large-scale current system is restored+ and its center is shifted to the pole, longitudinal current density being decreased. The invariant width of longitudinal currents is decreased, while the magnitude, Dsub(st), being increased, that is connected to the displacement of an auroral oval to the equator

  6. Magnetization reversal of Co-based amorphous wires induced by longitudinal AC magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Perov, N.S.; Antonov, A.S.; Buznikov, N.A.; Granovsky, A.B. E-mail: granov@magn.ru; Iakubov, I.T.; Kartashov, M.A.; Rakhmanov, A.A

    2004-05-01

    The remagnetization process in CoFeSiB amorphous wires under influence of a high-amplitude AC longitudinal magnetic field is studied. The frequency spectra of the voltage at the wire ends are measured as a function of a longitudinal DC magnetic field and the AC field amplitude. A high sensitivity of the voltage harmonics to the DC magnetic field is demonstrated. The experimental results are interpreted within a simple rotational model.

  7. Magnetization reversal of Co-based amorphous wires induced by longitudinal AC magnetic field

    International Nuclear Information System (INIS)

    Perov, N.S.; Antonov, A.S.; Buznikov, N.A.; Granovsky, A.B.; Iakubov, I.T.; Kartashov, M.A.; Rakhmanov, A.A.

    2004-01-01

    The remagnetization process in CoFeSiB amorphous wires under influence of a high-amplitude AC longitudinal magnetic field is studied. The frequency spectra of the voltage at the wire ends are measured as a function of a longitudinal DC magnetic field and the AC field amplitude. A high sensitivity of the voltage harmonics to the DC magnetic field is demonstrated. The experimental results are interpreted within a simple rotational model

  8. First national meeting of magnetic resonance and hyperfine interactions

    International Nuclear Information System (INIS)

    1985-07-01

    Works performed at CNEA's: Magnetic Resonance Division; Moessbauer Spectroscopy; Solid State Physics Division; Nuclear magnetic Resonance Laboratory and Theoretical Physics Group; Mossbauer Spectroscopy Group; Nuclear Quadrupole Resonance; Physics and Materials Group; Perturbed Angular Correlation and Moessbauer Spectroscopy and Physics Department. (M.E.L.) [es

  9. The particle concentration effect on magnetic resonance linewidth for magnetic liquids with chain aggregates

    International Nuclear Information System (INIS)

    Marin, C.N.

    2002-01-01

    Based on the assumption of particle chains formation within a magnetic liquid, computer simulation of the magnetic resonance line is presented. The dependence on particle concentration within a magnetic liquid of magnetic resonance linewidth is analyzed. The computer simulation demonstrates that the particles chaining has an important effect on the enlargement of the magnetic resonance line. Increasing the particle concentration within magnetic liquid leads to an increase in the linewidth. The agreement with some experimental findings is discussed

  10. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  11. Symmetry adaptation, operator equivalents and magnetic resonance

    International Nuclear Information System (INIS)

    Kibler, M.; Chatterjee, R.

    1977-12-01

    Basic quantities for symmetry adaptation are discussed in connection with molecular and solid state physics. This gives rise to a formalism whose the central elements are operator equivalents adapted to a point group. Such symmetry adapted operator equivalents are defined in terms of Schwinger operators so that they cover the off-diagonal and diagonal cases. Special emphasis is put on the applications of the formalism to magnetic resonance. More specifically, it is shown how to apply the formalism to the construction, the study of the transformation properties, and the determination of the eigenstates of a generalized spin hamiltonian. Numerous examples are given as well as key tables relative to the chain SO(3) for making easy the application of the formalism to electron paramagnetic resonance [fr

  12. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  13. Nanodiamond graphitization: a magnetic resonance study

    International Nuclear Information System (INIS)

    Panich, A M; Shames, A I; Sergeev, N A; Olszewski, M; McDonough, J K; Mochalin, V N; Gogotsi, Y

    2013-01-01

    We report on the first nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) study of the high-temperature nanodiamond-to-onion transformation. 1 H, 13 C NMR and EPR spectra of the initial nanodiamond samples and those annealed at 600, 700, 800 and 1800 ° C were measured. For the samples annealed at 600 to 800 ° C, our NMR data reveal the early stages of the surface modification, as well as a progressive increase in sp 2 carbon content with increased annealing temperature. Such quantitative experimental data were recorded for the first time. These findings correlate with EPR data on the sensitivity of the dangling bond EPR line width to air content, progressing with rising annealing temperature, that evidences consequent graphitization of the external layers of the diamond core. The sample annealed at 1800 ° C shows complete conversion of nanodiamond particles into carbon onions. (paper)

  14. Process of magnetic reconnection as a source of longitudinal currents

    International Nuclear Information System (INIS)

    Sidneva, M.V.; Semenov, V.S.

    1987-01-01

    Variations in magnetic field and current system as applied to conditions in the Earth magnetospheric tail are calculated so as to show that three-dimensional reconnection leads inevitably to the appearance of a system of longitudinal currents. With reference to current layer of the magnetospheric tail the longitudinal currents appearing in the process of reconnection are directed to the Earth on the morning side and from Earth - on the evening side. The results presented suggest that magnetic reconnection can serve as a sourse of the Birkeland current loop of a substorm

  15. Magnetic resonance tracking of fluorescent nanodiamond fabrication

    Science.gov (United States)

    Shames, A. I.; Osipov, V. Yu; Boudou, J. P.; Panich, A. M.; von Bardeleben, H. J.; Treussart, F.; Vul', A. Ya

    2015-04-01

    Magnetic resonance techniques (electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR)) are used for tracking the multi-stage process of the fabrication of fluorescent nanodiamonds (NDs) produced by high-energy electron irradiation, annealing, and subsequent nano-milling. Pristine commercial high pressure and high temperature microdiamonds (MDs) with mean size 150 μm contain ~5  ×  1018 spins/g of singlet (S = 1/2) substitutional nitrogen defects P1, as well as sp3 C-C dangling bonds in the crystalline lattice. The half-field X-band EPR clearly shows (by the appearance of the intense ‘forbidden’ g = 4.26 line) that high-energy electron irradiation and annealing of MDs induce a large amount (~5  ×  1017 spins/g) of triplet (S = 1) magnetic centers, which are identified as negatively charged nitrogen vacancy defects (NV-). This is supported by EPR observations of the ‘allowed’ transitions between Zeeman sublevels of the triplet state. After progressive milling of the fluorescent MDs down to an ultrasubmicron scale (≤100 nm), the relative abundance of EPR active NV- defects in the resulting fluorescent NDs (FND) substantially decreases and, vice versa, the content of C-inherited singlet defects correlatively increases. In the fraction of the finest FNDs (mean particle size fingerprint of the presence of NV- centers in small ND systems. The same size reduction causes the disappearance of the characteristic hyperfine satellites in the spectra of the P1 centers. We discuss the mechanisms that cause both the strong reduction of the peak intensity of the ‘allowed’ lines in EPR spectra of triplet defects and the transformation of the P1 spectra.

  16. Molecular structure and motion in zero field magnetic resonance

    International Nuclear Information System (INIS)

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed

  17. Measured longitudinal beam impedance of booster gradient magnets; TOPICAL

    International Nuclear Information System (INIS)

    James L Crisp and Brian J. Fellenz

    2001-01-01

    The Booster gradient magnets have no vacuum pipe which forces the beam image current to flow along the laminated pole tips. Both D and F style magnets were measured with a stretched wire to determine the longitudinal beam impedance caused by these laminations. Results are compared to calculations done 30 years ago. The inductive part of the magnet impedance is interesting because it partially compensates for the negative inductance effects of space charge on the beam. An R/L circuit consisting of 37K(center d ot) in parallel with between 40 and 100uH is a reasonable approximation to the total impedance of Booster magnet laminations

  18. The OMERACT rheumatoid arthritis magnetic resonance imaging (MRI) scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, Charles G.; Bird, Paul

    2017-01-01

    Objective: The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying...... inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. Methods: MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working...... Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Results: Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables...

  19. The role of cardiac magnetic resonance in valvular heart disease.

    Science.gov (United States)

    Lopez-Mattei, Juan C; Shah, Dipan J

    2013-01-01

    The prevalence of valvular heart disease is increasing as the population ages. In diagnosing individuals with valve disease, echocardiography is the primary imaging modality used by clinicians both for initial assessment and for longitudinal evaluation. However, in some cases cardiovascular magnetic resonance has become a viable alternative in that it can obtain imaging data in any plane prescribed by the scan operator, which makes it ideal for accurate investigation of all cardiac valves: aortic, mitral, pulmonic, and tricuspid. In addition, CMR for valve assessment is noninvasive, free of ionizing radiation, and in most instances does not require contrast administration. The objectives of a comprehensive CMR study for evaluating valvular heart disease are threefold: (1) to provide insight into the mechanism of the valvular lesion (via anatomic assessment), (2) to quantify the severity of the valvular lesion, and (3) to discern the consequences of the valvular lesion.

  20. Brain magnetic resonance imaging of infants exposed prenatally to buprenorphine

    International Nuclear Information System (INIS)

    Kahila, H.; Kivitie-Kallio, S.; Halmesmaki, E.; Valanne, L.; Autti, T.

    2007-01-01

    Purpose: To evaluate the brains of newborns exposed to buprenorphine prenatally. Material and Methods: Seven neonates followed up antenatally in connection with their mothers' buprenorphine replacement therapy underwent 1.5T magnetic resonance imaging (MRI) of the brain before the age of 2 months. The infants were born to heavy drug abusers. Four mothers were hepatitis C positive, and all were HIV negative. All mothers smoked tobacco and used benzodiazepines. All pregnancies were full term, and no perinatal asphyxia occurred. All but one neonate had abstinence syndrome and needed morphine replacement therapy. Results: Neither structural abnormalities nor abnormalities in signal intensity were recorded. Conclusion: Buprenorphine replacement therapy does not seem to cause any major structural abnormalities of the brain, and it may prevent known hypoxic-ischemic brain changes resulting from uncontrolled drug abuse. Longitudinal studies are needed to assess possible abnormalities in the brain maturation process

  1. Brain magnetic resonance imaging of infants exposed prenatally to buprenorphine

    Energy Technology Data Exchange (ETDEWEB)

    Kahila, H.; Kivitie-Kallio, S.; Halmesmaki, E.; Valanne, L.; Autti, T. [Dept. of Obstetrics and Gynecology, Dept. of Pediatrics, and Helsinki Medical Imaging Center, Helsinki Univ. Central Hospital (Finland)

    2007-02-15

    Purpose: To evaluate the brains of newborns exposed to buprenorphine prenatally. Material and Methods: Seven neonates followed up antenatally in connection with their mothers' buprenorphine replacement therapy underwent 1.5T magnetic resonance imaging (MRI) of the brain before the age of 2 months. The infants were born to heavy drug abusers. Four mothers were hepatitis C positive, and all were HIV negative. All mothers smoked tobacco and used benzodiazepines. All pregnancies were full term, and no perinatal asphyxia occurred. All but one neonate had abstinence syndrome and needed morphine replacement therapy. Results: Neither structural abnormalities nor abnormalities in signal intensity were recorded. Conclusion: Buprenorphine replacement therapy does not seem to cause any major structural abnormalities of the brain, and it may prevent known hypoxic-ischemic brain changes resulting from uncontrolled drug abuse. Longitudinal studies are needed to assess possible abnormalities in the brain maturation process.

  2. Magnetic resonance imaging of cleft palate

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Yasushi; Tasaka, Yasuyuki; Honjo, Iwao; Nishimura, Kazumasa; Nakano, Yoshihisa

    1987-03-01

    Magnetic resonance imaging (MRI) of the nasopharynx and the eustachian tube was performed in five patients with cleft palate and compared with the results of those without this anomaly. Various degrees of deformity of the eustachian tube cartilage were found in cleft palate patients. The levator veli palatini muscles were situated more laterally in cleft palate patients than in normal subjects. Also, changes in the position of these muscles after palatoplasty were clearly depicted by MRI. Besides several autopsy reports, this is the first demonstration of the characteristic anomaly around the eustachian tube by a non-invasive method.

  3. Magnetic resonance imaging of optic nerve

    International Nuclear Information System (INIS)

    Gala, Foram

    2015-01-01

    Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI), plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies

  4. Magnetic resonance imaging in cardiovascular disease

    International Nuclear Information System (INIS)

    Eckel, C.G.; Mettler, F.A. Jr.; Wicks, J.D.; Stevens, G.F.

    1986-01-01

    How does magnetic resonance imaging (MRI) currently contribute in the evaluation of patients with suspected heart disease? What role will MRI play in the future in evaluation of cardiovascular disease? To understand better where MRI fits into the diagnostic algorithm of cardiovascular disease the authors first consider the characteristics that they would like to see in the ideal diagnostic test and then survey the available cardiac diagnostic tests to note the characteristics that limit or recommend a test. In the final analysis, the justification for expensive diagnostic tests such as MRI must be an overall improvement in survival or quality of life in those patients treated after diagnosis

  5. Magnetic resonance imaging of pelvic endometriosis

    International Nuclear Information System (INIS)

    Vieira, G.P.; Martin, B.; Tubiana, J.M.

    1994-01-01

    Twenty-five magnetic resonance imaging (MRI) studies were performed in 18 patients with proven endometriosis. MRI findings were analyzed and compared with laparoscopic or surgical findings; MRI accurately demonstrated ovarian endometrial cysts as well as ectopic foci of endometriosis. Adhesions may be also suggested. Contrary to laparoscopy, MRI easily depicts both deep lesions and endometrial implants under the peritoneum. Consequently, MRI appears as an useful adjunct to laparoscopy for initial diagnosis before starting a medical treatment and above all as the imaging modality of choice for evaluation of the answer to treatment, avoiding iterative and often adhesions limited laparoscopies. (author). 7 refs.; 9 figs

  6. New magnetic resonance imaging methods in nephrology

    Science.gov (United States)

    Zhang, Jeff L.; Morrell, Glen; Rusinek, Henry; Sigmund, Eric; Chandarana, Hersh; Lerman, Lilach O.; Prasad, Pottumarthi Vara; Niles, David; Artz, Nathan; Fain, Sean; Vivier, Pierre H.; Cheung, Alfred K.; Lee, Vivian S.

    2013-01-01

    Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics. PMID:24067433

  7. Fetal magnetic resonance imaging and human genetics

    International Nuclear Information System (INIS)

    Hengstschlaeger, Markus

    2006-01-01

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data

  8. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  9. Magnetic resonance in hearing loss and vertigo

    Directory of Open Access Journals (Sweden)

    Manuel Ángel MARTÍN-PÉREZ

    2017-03-01

    Full Text Available Introduction and objective: Hearing loss and vertiginous syndrome represent an important part of the otorhinolaryngology clinic. The role of the radiologist plays in their workup become fundamental. Studies using magnetic resonance imaging (MRI are essential to guide or give the diagnosis in these cases. Method: After performing a retrospective analysis of 456 MRI studies of patients with these symptoms, we conducted a review of the main pathologies recorded that can cause these symptoms. Results: We classify into vascular disorders and other variants, tumor pathology, malformations and inflammatory pathology; We also describe the most relevant findings on MRI and illustrated with examples of our center.

  10. Nuclear magnetic resonance common laboratory, quadrennial report

    International Nuclear Information System (INIS)

    1994-01-01

    This quadrennial report of the nuclear magnetic resonance common laboratory gives an overview of the main activities. Among the different described activities, only one is interesting for the INIS database: it concerns the Solid NMR of cements used for radioactive wastes storage. In this case, the NMR is used to characterize the structure of the material and the composition, structure and kinetics of formation of the alteration layer which is formed at the surface of concrete during water leaching conditions. The NMR methodology is given. (O.M.)

  11. Magnetic resonance imaging of the cardiovascular system

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Imai, Hiroshi; Watanabe, Sigeru; Inagaki, Yoshiaki; Tateno, Yukio; Ikehira, Hiroo.

    1990-01-01

    Magnetic resonance imaging (MRI) is a new noninvasive technique for visualization of the cardiovascular system, and is used to evaluate tissue characteristics, cardiac function and blood flow abnormalities, as well as to obtain morphological information. In this paper we presented results of clinical and laboratory research obtained using conventional spin echo MRI with regard to cardiovascular anatomy, tissue characterization and physiology. Furthermore, experience with two new techniques, cine-MRI and volume-selected MR spectroscopy, and their potential clinical usefulness in detecting cardiovascular diseases are documented. (author)

  12. Nuclear magnetic resonance applications in biological systems

    International Nuclear Information System (INIS)

    Jiang Ling; Liu Maili

    2011-01-01

    Nuclear magnetic resonance (NMR) spectroscopy is a state-of-the-art technology which has been widely applied in biological systems over the past decades. It is a powerful tool for macromolecular structure determination in solution, and has the unique advantage of being capable of elucidating the structure and dynamic behavior of proteins during vital biomedical processes. In this review, we introduce the recent progress in NMR techniques for studying the structure, interaction and dynamics of proteins. The methods for NMR based drug discovery and metabonomics are also briefly introduced. (authors)

  13. Magnetic resonance imaging of the male pelvis

    International Nuclear Information System (INIS)

    Lamarque, J.L.; Rouanet, J.P.; Pujol, J.

    1986-01-01

    The authors present their preliminary results in the investigation of the male pelvis by means of a 0.35 Tesla superconductor apparatus. They present the different sequences used. The signal of the various pelvic organs in man is analysed together with the different anatomical possibilities. Magnetic resonance imaging appears to present very important advantages. The authors consider that the major limitations involve the prostate: new sequences of investigation, in particular a long TR, should be used for the purposes of tissue differentiation [fr

  14. Resonant magnetic pumping at very low frequency

    International Nuclear Information System (INIS)

    Canobbio, Ernesto

    1978-01-01

    We propose to exploit for plasma heating purposes the very low frequency limit of the Alfven wave resonance condition, which reduces essentially to safety factor q=m/n, a rational number. It is shown that a substantial fraction of the total RF-energy can be absorbed by the plasma. The lowest possible frequency value is determined by the maximum tolerable width of the RF-magnetic islands which develop near the singular surface. The obvious interest of the proposed scheme is the low frequency value (f<=10 KHz) which allows the RF-coils to be protected by stainless steel or even to be put outside the liner

  15. Proton magnetic resonance spectroscopy in schizophrenia

    International Nuclear Information System (INIS)

    Bertolino, Alessandro; Weinberger, Daniel R.

    1999-01-01

    Proton magnetic resonance spectroscopy (MRS) has become an important tool to study in vivo certain biochemical aspects of brain disorders. In the last decade this technique has been applied to the in vivo investigation of pathophysiological aspects of psychiatric disorders, extending knowledge of the related brain alterations. This review will focus on providing some background to clarify technical and biochemical issues and it will describe the studies that have been performed in schizophrenia. The results will be framed in a more general context to highlight what we have learned and what remains to be understood from the application of this technique to schizophrenia

  16. Lateral patellar luxation: magnetic resonance findings

    International Nuclear Information System (INIS)

    Armesto, V.; Pulpeiro, J.R.

    1995-01-01

    The objective of this article is to present the magnetic resonance (MR) findings associated with lateral patellar luxation. The series consisted of eight patients, all of whom presented joint effusion, damage to the medical retinaculum and cortical contusion or fracture of medical aspect of the patella or of anterolateral surface of the outer condyle. Five patients also presented patellar sub luxation. Diagnosis depends on the technique employed, with axial planes being very useful. Thus, it is recommended that they be used as the standard plane, especially in pathologies that are clinically unsuspicious as in this case. MR can also provide information that leads to surgical treatment rather than the standard conservative treatment. (Author)

  17. Indications for fetal magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Prayer, D.

    2006-01-01

    Indications to perform fetal magnetic resonance imaging (MRI) are composed of common ones related to methodological problems of ultrasound (US) assessment (such as for instance hydramnios) and special ones. The latter are related to MR capability of high-resolution soft tissue contrast and an extended field of view that allows visualization of the whole fetus, even in later stages of pregnancy. The most important indications include confirmation of US findings, work-up of malformations with respect to individual prognosis and genetic background, differentiation between acquired conditions and malformations, visualization of pathologies that have to be treated surgically immediately after birth, and morphological changes of the placenta. (orig.) [de

  18. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  19. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  1. Structural magnetic resonance imaging in epilepsy

    International Nuclear Information System (INIS)

    Deblaere, Karel; Achten, Eric

    2008-01-01

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  2. Magnetic resonance imaging of glenohumeral joint diseases

    International Nuclear Information System (INIS)

    Kieft, G.J.; Bloem, J.L.; Obermann, W.R.; Rozing, P.; Doornbos, J.

    1987-01-01

    Through the application of oblique planes and flexible surface coil techniques, magnetic resonance imaging (MRI) promises to be of great clinical value in the evaluation of a variety of pathologic conditions affecting the shoulder. In patients with joint effusions, the tendinous portion of the rotator cuff, glenoid labrum, and bicipital tendon can be readily visualized. This capability has particular relevance in patients with inflammatory disease and traumatic conditions. Rotator cuff atrophy and impingement of the coracoacromial arc upon the supraspinatus muscle and tendon can also be demonstrated. MRI is also useful in the evaluation of shoulder instability. (orig.)

  3. Structural magnetic resonance imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Deblaere, Karel [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium); Ghent University Hospital, MR Department - 1K12, Ghent (Belgium); Achten, Eric [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium)

    2008-01-15

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  4. Cardiac magnetic resonance assessment of takotsubo cardiomyopathy

    International Nuclear Information System (INIS)

    Abbas, A.; Sonnex, E.; Pereira, R.S.; Coulden, R.A.

    2016-01-01

    Takotsubo cardiomyopathy is an important condition that can be difficult to differentiate from acute coronary syndrome on the basis of clinical, electrocardiogram, and cardiac enzyme assessment alone. Although coronary angiography remains important in the acute assessment of patients with suspected takotsubo cardiomyopathy, cardiac magnetic resonance (CMR) has emerged over the last decade as an important non-invasive imaging tool in the diagnosis and follow-up of this condition. We present a review highlighting the CMR features of takotsubo cardiomyopathy and its complications with particular focus on differentiating this condition from acute myocardial infarction and myocarditis.

  5. Magnetic resonance imaging of spinal diseases

    International Nuclear Information System (INIS)

    Nakatani, Mariko; Sekiya, Toru; Harada, Junta; Kawakami, Kenji; Tada, Shimpei

    1985-01-01

    Twenty-two patients were examined to determine the clinical value of magnetic resonance imaging (MRI) in the spinal disease. Using different pulse sequences T 1 value was obtained from 38 spines; the result showed that increased T 1 value indicated spinal marrow abnormalities. A comparative study of MRI and bone scintigraphy was performed in 18 patients. Although it was not feasible to evaluate effect of therapy in metastatic disease by MRI, diffuse bone marrow disease, such as diffuse bone marrow metastases and blood dyscrasia could be detected by MRI. This limited study will suggest applicability of MRI in the spinal disease. (author)

  6. Sensorineural Hearing Loss after Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Abolfazl Mollasadeghi

    2013-01-01

    Full Text Available Magnetic resonance imaging (MRI devices produce noise, which may affect patient’s or operators’ hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus. In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient’s hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.

  7. Nanoplatforms for magnetic resonance imaging of cancer

    International Nuclear Information System (INIS)

    Cywinska, M. A.; Grudzinski, I. P.; Cieszanowski, A.; Bystrzejewski, M.; Poplawska, M.

    2011-01-01

    The application of biomedical nanotechnology in magnetic resonance imaging (MRI) is expect to have a major impact leading to the development of new contrast drug candidates on the nanoscale (1 - 100 nm) that are able to react with specific biological targets at a molecular level. One of the major challenges in this regard is the construction of nanomaterials, especially used in molecular MRI diagnostics of cancer in vivo, specialized antitumor drug delivery or real-time evaluation of the efficacy of the implemented cancer treatment. In this paper, we tried to gain further insights into current trends of nanomedicine, with special focus on preclinical MRI studies in translation cancer research. (authors)

  8. Nuclear magnetic resonance and medicine. Present applications

    International Nuclear Information System (INIS)

    1984-01-01

    At the workshop on nuclear magnetic resonance and medicine held at Saclay, the following topics were presented: physical principles of NMR; NMR spectroscopy signal to noise ratio; principles of NMR imaging; methods of NMR imaging; image options in NMR; biological significance of contrast in proton NMR imaging; measurement and significance of relaxation times in cancers; NMR contrast agents; NMR for in-vivo biochemistry; potential effects and hazards of NMR applications in Medicine; difficulties of NMR implantation in Hospitals; NMR imaging of brain tumors and diseases of the spinal cord; NMR and Nuclear Medicine in brain diseases [fr

  9. Cerebral fat embolism: magnetic resonance study

    International Nuclear Information System (INIS)

    Guedea, A.; Barrena, R.; Guelbenzu, S.; Tejada, A.

    1998-01-01

    We report the case of 26-year-old man who presented clinical evidence of fat embolism following a traffic accident. Although computed tomography (CT) of the brain showed no abnormalities, magnetic resonance imaging (MRI) disclosed several scattered points of high intensity on T2-weighted and proton density (PD) images, with complete resolution of the lesions on follow-up scan. MRI is considered more sensitive than computed tomography in detecting these lesions, and may be useful for their diagnosis, correlating well with the clinical course. (Author) 10 refs

  10. Developments in boron magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Schweizer, M.

    1995-01-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain

  11. Magnetic resonance imaging of the pediatric airway

    International Nuclear Information System (INIS)

    Auringer, S.T.; Bisset, G.S. III; Myer, C.M.

    1991-01-01

    Evaluation of the pediatric airway is often complex and may require multiple imaging techniques and invasive procedures. We performed magnetic resonance (MR) imaging of the airway in 34 children with clinical evidence of chronic airway obstruction and compared MR findings with those obtained by surgery and/or endoscopy. MR diagnoses included vascular compression in 15 patients, primary tracheomalacic states in 12 patients, and mediastinal masses in 4 patients. Findings were normal for 3 patients. The MR findings were in agreement with the endoscopic findings in 25 to 28 cases and in agreement with the surgical findings in 21 to 21 cases. (orig./GDG)

  12. Magnetic resonance of the renal transplantation

    International Nuclear Information System (INIS)

    Cauquil, P.; Hiesse, C.; Say, C.; Verdier, J.P.; Cauquil, M.; Brunet, A.M.; Galindo, R.; Tessier, J.P.

    1989-01-01

    Renal transplantation is the treatment of choice for renal insufficiency. Progress of surgical techniques and immuno-suppression have lead to better results. One year graft survival rate are 80% in most series. In this article, the role of imaging in renal transplantation, is defined. In surgical complications (fluid collections, obstruction, vascular insufficiency) non invasive radiology and interventionnal radiologic procedures have a great impact. Despite the perspectives of duplex and magnetic resonance, sensibility and specificity are not yet specified in medical complications: rejection, acute tubular necrosis, infection, drug toxicity. Association of these lesions is frequent and complicate analysis of results. Finally, transplant biopsy is still necessary to confirm the diagnosis [fr

  13. Clinical applications of cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C.

    2006-01-01

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  14. Parasellar meningiomas: magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Santos, Alair Augusto S.M.D. dos; Fontes, Cristina Asvolinsque P.

    2001-01-01

    We reviewed 22 cases of patients with parasellar meningiomas evaluated with magnetic resonance imaging (MRI) in private clinics of the cities of Niteroi and Rio de Janeiro, Rio de Janeiro State, Brazil. Our aim was to characterize the imaging findings in this type of tumor. MRI scanners with 0.5 and 1.0 Tesla magnets were used for the acquisition of multiplanar T1-weighted (pre-and post-gadolinium administration) and T2-weighted images. The main symptoms observed were headache and visual disturbances. Hyperprolactinaemia was observed in only one patient. The most frequent imaging finding was a parasellar mass which appeared hypointense on T1-weighted and hyperintense on T2-weighted images, and enhanced intensively after gadolinium administration. MRI is useful to demonstrate the lesion and to asses the damage to adjacent structures, particularly when the patient presents visual disturbances due to involvement of the cavernous sinuses. (author)

  15. Magnetic resonance imaging of parotid tumors, 1

    International Nuclear Information System (INIS)

    Nakamura, Akihiko; Yamashita, Toshio; Inoue, Toshiya; Kumazawa, Tadami; Kato, Tsutomu; Sawada, Satoshi; Tanaka, Yoshimasa

    1987-01-01

    We compared the usefulness of magnetic resonance imaging (MRI), with that of X-ray computed tomography in the preoperative diagnosis of parotid tumors. We performed in 13 patients with parotid tumors and 10 of them were operated. The MRI equipment had a magnetic fild of 0.15 Tesla. We used the spine echo acquisition technique and a repetition time of 600, 1000 and 2000 milli-seconds, and echo time of 40 and 80 milli-seconds. We found that the T 1 weighted image well visualized the duct of the parotid gland, the T 2 weighted image provided fine pictures of the parotid tumor. The facial nerve of normal parotid glands could not be visualized by MRI. (author)

  16. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  17. Shimadzu magnetic resonance imaging system, SMT-50

    International Nuclear Information System (INIS)

    Oikawa, Shiro; Nishida, Takayuki; Fujio, Yasuo

    1986-01-01

    The magnetic resonance imaging (MRI) system, as a new modality of medical imaging, has already been put to practical applications on many clinical sites, through which a lot of clinical data has been accumulated. It can offer a powerful new probe of internal anatomy of the human body and its functions. Now that the MRI has established its effectiveness in diagnosis, a really practical MRI system which features high efficiency and economical design with high patient throughput is strongly called for. Introduced in this article is a superconductive magnet MRI system, SMT-50, operating at 5000 Gauss. It has realized an excellent diagnostic capability with such functions as multi-slice multi-echo imaging, high sensitive, surface coil technique and so on. High resolution image display (1024 x 1024 pixcel) unit and separate console system (viewing console and scanning console) will assist high patient throughput. The outline of the SMT-50 and its clinical data are reported here. (author)

  18. On effect of stability of magnetic resonance position by harmonized field

    International Nuclear Information System (INIS)

    Ivanchenko, E.A.; Tolstoluzhsky, A.P.

    2006-01-01

    The formalism of density matrix in a two level system is used to study the time-periodic modulation of the magnetic field stabilizating the magnetic resonance position. An exact solution for density matrix at resonance is found. It is shown that the fundamental resonance is stable with respect to consistent variations of longitudinal and transversal magnetic fields. A differential equation for the transition probability is obtained. The dependence of time-averaged spin flip probability on the normalized Larmor frequency was numerically researched in different parameter regimes with account of dissipation and decoherence. It is shown that the position of the main resonance is independent of field deformation and dissipation; only the width of resonance line changes upon field deformation and dissipation. The odd parametric (multi-photon) resonance transitions is studied. Static magnetization induced by time-periodic modulated magnetic field is considered. The results of the investigation may be useful for analysis of interference experiments, improvement of magnetic spectrometers and in the field of quantum computing manipulation of q-bits

  19. Pulse sequences for contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Graves, Martin J.

    2007-01-01

    The theory and application of magnetic resonance imaging (MRI) pulse sequences following the administration of an exogenous contrast agent are discussed. Pulse sequences are categorised according to the contrast agent mechanism: changes in proton density, relaxivity, magnetic susceptibility and resonant frequency shift. Applications in morphological imaging, magnetic resonance angiography, dynamic imaging and cell labelling are described. The importance of optimising the pulse sequence for each application is emphasised

  20. Deep-level defects in semiconductors: studies by magnetic resonance

    International Nuclear Information System (INIS)

    Ammerlaan, C.A.J.

    1983-01-01

    This work is divided into two parts. In the first one, the following topics are discussed: paramagnetic centers in semiconductors, principles of magnetic resonance, spin-Hamiltonian, g-tensor, hyperfine interaction, magnetic resonance spectrometer. In the second part it is dicussed defects studied by magnetic resonance including vacancy and divacancy in silicon, iron in silicon, nitrogen in diamond and antisite defects in III-V compounds. (A.C.A.S.) [pt

  1. Magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Norman, D.

    1987-01-01

    This book presents the papers on technological advancement and diagnostic uses g magnetic resonance imaging. A comparative evaluation with computerized tomography is presented. Topics covered are imaging principles g magnetic resonance;instrumentation of magnetic resonance (MR);pathophysiology;quality and limitations g images;NMR imaging of brain and spinal cord;MR spectroscopy and its applications;neuroanatomy;Congenital malformations of brain and MR imaging;planning g MR imaging of spine and head and neck imaging

  2. Suppressing magnetic island growth by resonant magnetic perturbation

    Science.gov (United States)

    Yu, Q.; Günter, S.; Lackner, K.

    2018-05-01

    The effect of externally applied resonant magnetic perturbations (RMPs) on the growth of magnetic islands is investigated based on two-fluid equations. It is found that if the local bi-normal electron fluid velocity at the resonant surface is sufficiently large, static RMPs of the same helicity and of moderate amplitude can suppress the growth of magnetic islands in high-temperature plasmas. These islands will otherwise grow, driven by an unfavorable plasma current density profile and bootstrap current perturbation. These results indicate that the error field can stabilize island growth, if the error field amplitude is not too large and the local bi-normal electron fluid velocity is not too low. They also indicate that applied rotating RMPs with an appropriate frequency can be utilized to suppress island growth in high-temperature plasmas, even for a low bi-normal electron fluid velocity. A significant change in the local equilibrium plasma current density gradient by small amplitude RMPs is found for realistic plasma parameters, which are important for the island stability and are expected to be more important for fusion reactors with low plasma resistivity.

  3. Magnetic resonance imaging of the bone marrow

    International Nuclear Information System (INIS)

    Baur-Melnyk, Andrea

    2013-01-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  4. Nuclear magnetic resonance in cardiology: cardiac MRI

    International Nuclear Information System (INIS)

    Fernandez, Claudio C.

    2003-01-01

    As a new gold standard for mass, volume and flow, the magnetic resonance imaging (MRI) is probably the most rapidly evolving technique in the cardiovascular diagnosis. An integrated cardiac MRI examination allows the evaluation of morphology, global and regional function, coronary anatomy, perfusion, viability and myocardial metabolism, all of them in only one diagnostic test and in a totally noninvasive manner. The surgeons can obtain relevant information on all aspects of diseases of the heart and great vessels, which include anatomical details and relationships with the greatest field of view, and may help to reduce the number of invasive procedures required in pre and postoperative evaluation. However, despite these excellent advantages the present clinical utilization of MRI is still too often restricted to few pathologies or case studies in which other techniques fail to identify the cardiac or cardiovascular abnormalities. If magnetic resonance is an excellent method for diagnosing so many different cardiac conditions, why is so little it used in routine cardiac practice? Cardiologists are still not very familiar with the huge possibilities or cardiovascular MRI utilities. Our intention is to give a comprehensive survey of many of the clinical applications of this challenger technique in the study of the heart and great vessels. Those who continue to ignore this important and mature imaging technique will rightly fail to benefit. (author) [es

  5. Magnetic Resonance Imaging of Liver Metastasis.

    Science.gov (United States)

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Smart Contrast Agents for Magnetic Resonance Imaging.

    Science.gov (United States)

    Bonnet, Célia S; Tóth, Éva

    2016-01-01

    By visualizing bioactive molecules or biological parameters in vivo, molecular imaging is searching for information at the molecular level in living organisms. In addition to contributing to earlier and more personalized diagnosis in medicine, it also helps understand and rationalize the molecular factors underlying physiological and pathological processes. In magnetic resonance imaging (MRI), complexes of paramagnetic metal ions, mostly lanthanides, are commonly used to enhance the intrinsic image contrast. They rely either on the relaxation effect of these metal chelates (T(1) agents), or on the phenomenon of paramagnetic chemical exchange saturation transfer (PARACEST agents). In both cases, responsive molecular magnetic resonance imaging probes can be designed to report on various biomarkers of biological interest. In this context, we review recent work in the literature and from our group on responsive T(1) and PARACEST MRI agents for the detection of biogenic metal ions (such as calcium or zinc), enzymatic activities, or neurotransmitter release. These examples illustrate the general strategies that can be applied to create molecular imaging agents with an MRI detectable response to biologically relevant parameters.

  7. Magnetic resonance spectroscopy: clinical application in neuroradiology

    International Nuclear Information System (INIS)

    Penev, L.

    2012-01-01

    Full text: Magnetic Resonance Spectroscopy (MRS) provides a non-invasive method of studying metabolism in vivo. Magnetic resonance spectroscopy (MRS) defines neuro chemistry on a regional basis by acquiring a radiofrequency signal with chemical shift from one or many voxels or volumes previously selected on MRI. The tissue's chemical environment determines the frequency of a metabolite peak in an MRS spectrum. Candidates for MRS include: 1 H, 31 P, 13 C, 23 Na, 7 Li, 19 F, 14 N, 15 N, 17 O, 39 K The most commonly studied nuclei are 1 H and 31 P. This lecture is focused on Proton ( 1 H) Spectroscopy. Proton MRS can be added on to conventional MR imaging protocols. It can be used to serially monitor biochemical changes in tumors, stroke, epilepsy, metabolic disorders, infections, and neurodegenerative diseases.The MR spectra do not come labeled with diagnoses. They require interpretation and should always be correlated with the MR images before making a final diagnosis. As a general rule, the single voxel, short TE technique is used to make the initial diagnosis, because the signal-to-noise is high and all metabolites are represented. Multi-voxel, long TE techniques are used to further characterize different regions of a mass and to assess brain parenchyma around or adjacent to the mass. Multi-voxel, long TE techniques are also used to assess response to therapy and to search for tumor recurrence. Each metabolite appears at a specific ppm, and each one reflects specific cellular and biochemical processes

  8. [Surface coils for magnetic-resonance images].

    Science.gov (United States)

    Rodríguez-González, Alfredo Odón; Amador-Baheza, Ricardo; Rojas-Jasso, Rafael; Barrios-Alvarez, Fernando Alejandro

    2005-01-01

    Since the introduction of magnetic resonance imaging in Mexico, the development of this important medical imaging technology has been almost non-existing in our country. The very first surface coil prototypes for clinical applications in magnetic resonance imaging has been developed at the Center of Research in Medical Imaging and Instrumentation of the Universidad Autónoma Metropolitana Iztapalapa (Metropolitan Autonomous University, Campus Iztapalapa). Two surface coil prototypes were built: a) a circular-shaped coil and b) a square-shaped coil for multiple regions of the body, such as heart, brain, knee, hands, and ankles. These coils were tested on the 1.5T imager of the ABC Hospital-Tacubaya, located in Mexico City. Brain images of healthy volunteers were obtained in different orientations: sagittal, coronal, and axial. Since images showed a good-enough clinical quality for diagnosis, it is fair to say that these coil prototypes can be used in the clinical environment, and with small modifications, they can be made compatible with almost any commercial scanner. This type of development can offer new alternatives for further collaboration between the research centers and the radiology community, in the search of new applications and developments of this imaging technique.

  9. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  10. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  11. Magnetic resonance spectroscopy as an imaging method

    International Nuclear Information System (INIS)

    Bomsdorf, H.; Imme, M.; Jensen, D.; Kunz, D.; Menhardt, W.; Ottenberg, K.; Roeschmann, P.; Schmidt, K.H.; Tschendel, O.; Wieland, J.

    1990-01-01

    An experimental Magnetic Resonance (MR) system with 4 tesla flux density was set up. For that purpose a data acquisition system and RF coils for resonance frequencies up to 170 MHz were developed. Methods for image guided spectroscopy as well as spectroscopic imaging focussing on the nuclei 1 H and 13 C were developed and tested on volunteers and selected patients. The advantages of the high field strength with respect to spectroscopic studies were demonstrated. Developments of a new fast imaging technique for the acquisition of scout images as well as a method for mapping and displaying the magnetic field inhomogeneity in-vivo represent contributions to the optimisation of the experimental procedure in spectroscopic studies. Investigations on the interaction of RF radiation with the exposed tissue allowed conclusions regarding the applicability of MR methods at high field strengths. Methods for display and processing of multi-dimensional spectroscopic imaging data sets were developed and existing methods for real-time image synthesis were extended. Results achieved in the field of computer aided analysis of MR images comprised new techniques for image background detection, contour detection and automatic image interpretation as well as knowledge bases for textural representation of medical knowledge for diagnosis. (orig.) With 82 refs., 3 tabs., 75 figs [de

  12. Magnetic resonance imaging of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, Andrea (ed.) [Klinikum der Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-08-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  13. Reciprocity and gyrotropism in magnetic resonance transduction

    International Nuclear Information System (INIS)

    Tropp, James

    2006-01-01

    We give formulas for transduction in magnetic resonance - i.e., the appearance of an emf due to Larmor precession of spins - based upon the modified Lorentz reciprocity principle for gyrotropic (also called 'nonreciprocal') media, i.e., in which a susceptibility tensor is carried to its transpose by reversal of an external static field [cf., R. F. Harrington and A. T. Villeneuve IRE Trans. Microwave Theory and Technique MTT6, 308 (1958)]. Prior applications of reciprocity to magnetic resonance, despite much success, have ignored the gyrotropism which necessarily arises due to nuclear and/or unpaired electronic spins. For detection with linearly polarized fields, oscillating at the Larmor frequency, the emf is written in terms of a volume integral containing a product of two factors which we define as the antenna patterns, i.e. (H 1x ±iH 1y ), where, e.g., for a single transceive antenna, the H's are just the spatially dependent oscillatory magnetic field strengths, per the application of some reference current at the antenna terminals, with the negative sign obtaining for transmission, and the positive for reception. Similar expressions hold for separate transmit and receive antennas; expressions are also given for circular polarization of the fields. We then exhibit a receive-only array antenna of two elements for magnetic resonance imaging of protons, which, due an intensity artifact arising from stray reactive coupling of the elements, produces, despite its own bilateral symmetry, asymmetric proton NMR images of a symmetric cylindrical phantom containing aqueous saline solution [J. Tropp and T. Schirmer, J. Magn. Reson. 151, 146 (2001)]. Modification of this two-port antenna, to function in transmit-receive mode, allows us to demonstrate highly nonreciprocal behavior: that is, to record images (of cylindrical test phantoms containing aqueous saline solution) whose appearance dramatically changes, when the roles of transmission and reception are swapped between

  14. Proceedings of the nuclear magnetic resonance user meeting

    International Nuclear Information System (INIS)

    1987-01-01

    Studies on utilization of nuclear magnetic resonance, such as: chemical analysis in complexes and organic compounds; structures and magnetic properties of solids; construction of images and; spectrometer designs, are presented. (M.C.K.) [pt

  15. Resonance of magnetization excited by voltage in magnetoelectric heterostructures

    Science.gov (United States)

    Yu, Guoliang; Zhang, Huaiwu; Li, Yuanxun; Li, Jie; Zhang, Dainan; Sun, Nian

    2018-04-01

    Manipulation of magnetization dynamics is critical for spin-based devices. Voltage driven magnetization resonance is promising for realizing low-power information processing systems. Here, we show through Finite Element Method (FEM) simulations that magnetization resonance in nanoscale magnetic elements can be generated by a radio frequency (rf) voltage via the converse magnetoelectric (ME) effect. The magnetization dynamics induced by voltage in a ME heterostructures is simulated by taking into account the magnetoelastic and piezoelectric coupling mechanisms among magnetization, strain and voltage. The frequency of the excited magnetization resonance is equal to the driving rf voltage frequency. The proposed voltage driven magnetization resonance excitation mechanism opens a way toward energy-efficient spin based device applications.

  16. Chiral discrimination in nuclear magnetic resonance spectroscopy

    Science.gov (United States)

    Lazzeretti, Paolo

    2017-11-01

    Chirality is a fundamental property of molecules whose spatial symmetry is characterized by the absence of improper rotations, making them not superimposable to their mirror image. Chiral molecules constitute the elementary building blocks of living species and one enantiomer is favoured in general (e.g. L-aminoacids and D-sugars pervade terrestrial homochiral biochemistry) because most chemical reactions producing natural substances are enantioselective. Since the effect of chiral chemicals and drugs on living beings can be markedly different between enantiomers, the quest for practical spectroscopical methods to scrutinize chirality is an issue of great importance and interest. Nuclear magnetic resonance (NMR) is a topmost analytical technique, but spectrometers currently used are ‘blind’ to chirality, i.e. unable to discriminate the two mirror-image forms of a chiral molecule, because, in the absence of a chiral solvent, the spectral parameters, chemical shifts and spin-spin coupling constants are identical for enantiomers. Therefore, the development of new procedures for routine chiral recognition would offer basic support to scientists. However, in the presence of magnetic fields, a distinction between true and false chirality is mandatory. The former epitomizes natural optical activity, which is rationalized by a time-even pseudoscalar, i.e. the trace of a second-rank tensor, the mixed electric dipole/magnetic dipole polarizability. The Faraday effect, magnetic circular dichroism and magnetic optical activity are instead related to a time-odd axial vector. The present review summarizes recent theoretical and experimental efforts to discriminate enantiomers via NMR spectroscopy, with the focus on the deep connection between chirality and symmetry properties under the combined set of fundamental discrete operations, namely charge conjugation, parity (space inversion) and time (motion) reversal.

  17. Ultra high field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lethimonnier, F.; Vedrine, P.

    2007-01-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  18. State of the art magnetic resonance imaging

    International Nuclear Information System (INIS)

    Weissman, J.D.

    1987-01-01

    In less than a decade Magnetic Resonance Imaging (MRI) has evolved from a laboratory demonstration to a safe and effective technique for clinical diagnosis. This evolutionary process continues. At this time 2-D and 3-D imaging of the head and body is firmly established in clinical use. Surface coil imaging, two-component chemical shift imaging, in-vivo spectroscopy and flow imaging are currently in various stages of development. The present state of the art of MRI is a function of an array of technologies: magnet, Rf coil, Rf pulse amplifier, gradient coil and driver, pulse programmer, A/D converter, computer system architecture, array processors and mass storage (both magnetic and optical). The overall product design is the result of a complex process which balances the advantages and disadvantages of each component for optimal system performance and flexibility. The author discusses the organization of a state-of-the-art MRI system. Several examples of the kinds of system interactions affecting design choices are given. (Auth.)

  19. Spatial localization in nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Keevil, Stephen F

    2006-01-01

    The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications. (topical review)

  20. Longitudinal Stretching for Maturation of Vascular Tissues Using Magnetic Forces

    Directory of Open Access Journals (Sweden)

    Timothy R. Olsen

    2016-11-01

    Full Text Available Cellular spheroids were studied to determine their use as “bioinks” in the biofabrication of tissue engineered constructs. Specifically, magnetic forces were used to mediate the cyclic longitudinal stretching of tissues composed of Janus magnetic cellular spheroids (JMCSs, as part of a post-processing method for enhancing the deposition and mechanical properties of an extracellular matrix (ECM. The purpose was to accelerate the conventional tissue maturation process via novel post-processing techniques that accelerate the functional, structural, and mechanical mimicking of native tissues. The results of a forty-day study of JMCSs indicated an expression of collagen I, collagen IV, elastin, and fibronectin, which are important vascular ECM proteins. Most notably, the subsequent exposure of fused tissue sheets composed of JMCSs to magnetic forces did not hinder the production of these key proteins. Quantitative results demonstrate that cyclic longitudinal stretching of the tissue sheets mediated by these magnetic forces increased the Young’s modulus and induced collagen fiber alignment over a seven day period, when compared to statically conditioned controls. Specifically, the elastin and collagen content of these dynamically-conditioned sheets were 35- and three-fold greater, respectively, at seven days compared to the statically-conditioned controls at three days. These findings indicate the potential of using magnetic forces in tissue maturation, specifically through the cyclic longitudinal stretching of tissues.

  1. Soft x-ray resonant diffraction study of magnetic structure in magnetoelectric Y-type hexaferrite

    Science.gov (United States)

    Ueda, H.; Tanaka, Y.; Wakabayashi, Y.; Kimura, T.

    2018-05-01

    The effect of magnetic field on the magnetic structure associated with magnetoelectric properties in a Y-type hexaferrite, Ba1.3Sr0.7CoZnFe11AlO22, was investigated by utilizing the soft x-ray resonant diffraction technique. In this hexaferrite, the so-called alternating longitudinal conical phase is stabilized at room temperature and zero magnetic field. Below room temperature, however, this phase is transformed into the so-called transverse conical phase by applying an in-plane magnetic field (≈ 0.3 T). The transverse conical phase persists even after removing the magnetic field. The magnetoelectricity, which is magnetically-induced electric polarization, observed in the hexaferrite is discussed in terms of the temperature-dependent magnetic structure at zero field.

  2. Magnetic resonance tracking of fluorescent nanodiamond fabrication

    International Nuclear Information System (INIS)

    Shames, A I; Panich, A M; Osipov, V Yu; Vul’, A Ya; Boudou, J P; Treussart, F; Von Bardeleben, H J

    2015-01-01

    Magnetic resonance techniques (electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR)) are used for tracking the multi-stage process of the fabrication of fluorescent nanodiamonds (NDs) produced by high-energy electron irradiation, annealing, and subsequent nano-milling. Pristine commercial high pressure and high temperature microdiamonds (MDs) with mean size 150 μm contain ∼5  ×  10 18  spins/g of singlet (S = 1/2) substitutional nitrogen defects P1, as well as sp 3 C–C dangling bonds in the crystalline lattice. The half-field X-band EPR clearly shows (by the appearance of the intense ‘forbidden’ g = 4.26 line) that high-energy electron irradiation and annealing of MDs induce a large amount (∼5  ×  10 17  spins/g) of triplet (S = 1) magnetic centers, which are identified as negatively charged nitrogen vacancy defects (NV − ). This is supported by EPR observations of the ‘allowed’ transitions between Zeeman sublevels of the triplet state. After progressive milling of the fluorescent MDs down to an ultrasubmicron scale (≤100 nm), the relative abundance of EPR active NV − defects in the resulting fluorescent NDs (FND) substantially decreases and, vice versa, the content of C-inherited singlet defects correlatively increases. In the fraction of the finest FNDs (mean particle size <20 nm), which are contained in the dried supernatant of ultracentrifuged aqueous dispersion of FNDs, the NV − content is found to be reduced by one order of magnitude whereas the singlet defects content increases up to ∼2  ×  10 19  spins/g. In addition, another triplet-type defect, which is characterized by the g = 4.00 ‘forbidden’ line, appears. On reduction of the particle size below the 20 nm limit, the ‘allowed’ EPR lines become practically unobservable, whereas the ‘forbidden’ lines remain as a reliable fingerprint of the presence of NV − centers in small ND systems. The same size reduction

  3. Magnetic resonance imaging of spinal cord injury in chronic stage

    International Nuclear Information System (INIS)

    Tobimatsu, Haruki; Nihei, Ryuichi; Kimura, Tetsuhiko; Yano, Hideo; Touyama, Tetsuo; Tobimatsu, Yoshiko; Suyama, Naoto; Yoshino, Yasumasa

    1991-01-01

    Magnetic resonance (MR) images of a total of 195 patients with cervical (125) or thoracic (70) spinal cord injury were reviewed. The imaging studies of the spinal cord lesions were correlated with clinical manifestations. Sequential MR imaging revealed hypointensity on T1-weighted images (T1WI) and hyperintensity on T2-weighted images (T2WI) in all patients, except for five patients showing no signal changes and two showing isointensity, suggesting gliosis, myelomalacia, and syringomyelia. Spinal cord lesions were classified into four types: small lesions, large lesions, complete transverse, and longitudinal rupture. These lesions were well correlated with the severity of injury and paralysis. Complete paralysis was frequently associated with enlarged, complete transverse for cervical spinal cord injury, and longitudinal ruptured or thinned complete transverse for thoracic spinal cord injury. The height of paralysis was well in agreement with that of lesions. For incomplete paralysis, localized lesions were seen within the spinal cord, coinciding with the paralysis or severity. Traumatic syringomyelia was seen in 17 patients (8.7%)-- for the cervical site (10 patients, 8%) and the thoracic site (7 patients, 10%). When homogeneous and marginally clear hypointensity is shown on T1-weighted images and vacuolated hyperintensity is shown on T2-weighted images, in addition to lesions spreading two or more cords or 1.5 or more cords above the nervous root level of paralysis, traumatic syringomyelia is strongly suspected, requiring the follow up observation. (N.K.)

  4. Sustained postinfarction myocardial oedema in humans visualised by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Nilsson, J C; Nielsen, G; Grønning, Bjørn Aaris

    2001-01-01

    OBJECTIVE: To demonstrate postinfarction myocardial oedema in humans with particular reference to the longitudinal course, using magnetic resonance imaging (MRI). DESIGN: Prospective observational study. Subjects were studied one week, one month, three months, six months, and one year after...... presenting with a myocardial infarct. SETTING: Cardiology and magnetic resonance departments in a Danish university hospital. PATIENTS: 10 patients (three women, seven men), mean (SEM) age 58.2 (3.20) years, with a first transmural myocardial infarct. MAIN OUTCOME MEASURES: Location and duration...... of postinfarction myocardial oedema. RESULTS: All patients had signs of postinfarction myocardial oedema. The magnetic resonance images were evaluated by two blinded procedures, employing two MRI and two ECG observers: (1) MRI determined oedema location was compared with the ECG determined site of infarction...

  5. Nuclear magnetic resonance studies of lens transparency

    International Nuclear Information System (INIS)

    Beaulieu, C.F.

    1989-01-01

    Transparency of normal lens cytoplasm and loss of transparency in cataract were studied by nuclear magnetic resonance (NMR) methods. Phosphorus ( 31 P) NMR spectroscopy was used to measure the 31 P constituents and pH of calf lens cortical and nuclear homogenates and intact lenses as a function of time after lens enucleation and in opacification produced by calcium. Transparency was measured with laser spectroscopy. Despite complete loss of adenosine triphosphate (ATP) within 18 hrs of enucleation, the homogenates and lenses remained 100% transparent. Additions of calcium to ATP-depleted cortical homogenates produced opacification as well as concentration-dependent changes in inorganic phosphate, sugar phosphates, glycerol phosphorylcholine and pH. 1 H relaxation measurements of lens water at 200 MHz proton Larmor frequency studied temperature-dependent phase separation of lens nuclear homogenates. Preliminary measurements of T 1 and T 2 with non-equilibrium temperature changes showed a change in the slope of the temperature dependence of T 1 and T 2 at the phase separation temperature. Subsequent studies with equilibrium temperature changes showed no effect of phase separation on T 1 or T 2 , consistent with the phase separation being a low-energy process. 1 H nuclear magnetic relaxation dispersion (NMRD) studies (measurements of the magnetic field dependence of the water proton 1/T 1 relaxation rates) were performed on (1) calf lens nuclear and cortical homogenates (2) chicken lens homogenates, (3) native and heat-denatured egg white and (4) pure proteins including bovine γ-II crystallin bovine serum albumin (BSA) and myoglobin. The NMRD profiles of all samples exhibited decreases in 1/T 1 with increasing magnetic field

  6. Magnetic resonance arthrography in chronic wrist pain

    International Nuclear Information System (INIS)

    Valeri, G.; Ferrara, C.; Carloni, S.

    1999-01-01

    The purpose of this paper is to investigate the clinical role of Magnetic Resonance Arthrography (MRA) of the wrist in subjects with chronic pain. Thirty-five patients complaining of wrist pain for more than 6 months were submitted to MRI an MRA. All patients received and intra-articular injection of 2-10 mL of a 10 mmol saline solution of Gd-DPTA. The overall diagnostic accuracy rates of MRI and MRA were 40% and 81% respectively, with sensitivity and specificity of 63% and 39% (MRI) and of 82% and 79% (MRA). The conclusion is that compared with MRI, MRA can be considered a useful tool for the visualization of interosseus carpal ligaments and of the triangular fibrocartilage complex. MRA also helps detect injuries in these structures [it

  7. Magnetic resonance tomography of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Tscholakoff, D.

    1987-01-01

    In this experimental study (canine heart) a variety of pathologic conditions of the myocardium were studied using ECG-triggered magnetic resonance imaging (MRI). The purpose of this study was to examine the MR appearance and the T/sub 2/ relaxation times of occlusive and reperfused myocardial infarcts, of hypertrophic cardiomyopathy and of cardiac transplants with and without acute cardiac allograft rejection. MR images were correlated with the results of histology and tissue water content. MRI identified normal myocardium with T/sub 2/ values of 38 (+-4.3) msec. Myocardial infarcts and acute allograft rejection had significant (p<0.05) longer T/sub 2/ values compared to normal myocardium. On the basis of T/sub 2/ relaxation times no further differentiation among different pathologic entities was possible. Therefore, it is necessary to include morphologic criteria such as myocardial wall thickness, cardiac chamber size and intracavitary blood flow signal in the interpretation of cardiac MR tomograms.

  8. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  9. Cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Shiozaki, Afonso Akio; Parga, Jose Rodrigues; Arteaga, Edmundo; Rochitte, Carlos Eduardo; Tassi, Eduardo Marinho

    2007-01-01

    Hypertrophic cardiomyopathy (HCM) is the most frequent genetic cardiac disease that causes sudden death in young people, with an incidence of 1:500 adults. The routinely used criteria for worst prognosis have limited sensitivity and specificity. Thus, the estimated risk of evolving to dilated cardiomyopathy or sudden death is somewhat inaccurate, leading to management uncertainty of HCM patients. Therefore, an accurate noninvasive method for the diagnosis of HCM with prognostic value is of great importance. In the last years, Cardiovascular Magnetic Resonance (CMR) emerged not only as a diagnostic tool, but also as a study with prognostic values, by characterizing myocardial fibrosis with great accuracy in HCM patients. Additionally, CMR identifies the types of hypertrophy, analyses the ventricular function, estimates the intraventricular gradient and allows the determination of differential diagnosis. Moreover, CMR can uniquely access myocardial fibrosis in HCM. (author)

  10. Magnetic resonance imaging for cardiac tumors

    International Nuclear Information System (INIS)

    Niwa, Koichiro; Tashima, Kazuyuki; Okajima, Yoshitomo; Nakajima, Hiromichi; Terai, Masaru; Nakajima, Hironori; Harada, Tsutomu; Ishida, Yoshikazu.

    1988-01-01

    We performed magnetic resonance imaging (MRI) in 4 patients with cardiac tumor (1 with rhabdomyoma, 1 with left atrial myxoma, and 2 with tumor of the left ventricular wall) for morphological evaluation of the tumor. ECG-gated MRI was performed by the spin echo imaging technique using a superconducting MRI system operating at 0.5 tesla. Spatial extension of the tumor was clearly demonstrated in all the patients. Gadolinium-DTPA (Gd-DTPA), was used in the 2 patients with tumor of the left ventricular myocardium to enhance the contrast, and allowed clear visualization of the tumor. These findings show the usefulness of MRI and MRI with Gd-DTPA for morphological evaluation of cardiac tumor. (author)

  11. Basic concepts from magnetic resonance imaging

    International Nuclear Information System (INIS)

    Rodriguez Arroyo, Diego

    2011-01-01

    The use of magnetic resonance imaging (MRI) has grown exponentially, due in part to excellent anatomic and pathologic detail provided by the modality, as recent technological advances that have led to more rapid acquisition times. Radiology residents in different parts of the world now receive training in MR images from their first year of residence, included the pulse sequences training spin-echo, gradient-echo, inversion-recovery, echo-planar image and MR angiographic sequences, commonly used in medical imaging. However, to optimize the use of this type of study, it has been necessary to understand the basic concepts of physics, included the concepts of recovery T1, degradation T2* and T2, repetition time, echo time, and the effects of chemical shift. Additionally, it has been important to understand the contrast weighting for better representation of specific tissues and thus perform an appropriate differential diagnosis of various pathological processes. (author) [es

  12. Magnetic resonance imaging in pediatric neurological disease

    International Nuclear Information System (INIS)

    Tsukiyama, Takashi; Nishimoto, Hiroshi; Fujioka, Mutsuhisa; Aihara, Toshinori; Tanaka, Osamu.

    1986-01-01

    In this paper, we summarize our initial experience with Magnetic Resonance Imaging(MRI) in the evaluation of pediatric neurological disease. 17 children between the ages of 2 month and 8.5 year have been examined with MRI. All subjects tolerated the MRI procedure well, although sedation was necessary for young children. Result as follows : (1) MRI does not utilize ionising radiation to produce an image. (2) MRI images more clearly demonstrate cerebral gray and white matter than X-ray CT. (3) Compared with X-ray CT, MRI proved to be advantageous in detection and characterization of the pathology, especially when the abnormality was located along the posterior fossa and spinal canal. It is suggested that these nature of MRI makes it the ideal diagnostic method for children. (author)

  13. Nuclear magnetic resonance imaging of the thorax

    International Nuclear Information System (INIS)

    Gamsu, G.; Webb, W.R.; Sheldon, P.; Kaufman, L.; Crooks, L.E.; Birnberg, F.A.; Goodman, P.; Hinchcliffe, W.A.; Hedgecock, M.

    1983-01-01

    Nuclear magnetic resonance (NMR) images of the thorax were obtained in ten normal volunteers, nine patients with advanced bronchogenic carcinoma, and three patients with benign thoracic abnormalities. In normal volunteers, mediastinal and hilar structures were seen with equal frequency on NMR images and computed tomographic scans. The hila were especially well displayed on spin-echo images. Spin-echo images showed mediastinal invasion by tumor, vascular and bronchial compression and invasion, and hilar and mediastinal adenopathy. Tumor and benign abnormalities could be separated from mediastinal and hilar fat because of their longer T1 times. Lung masses and nodules as small as 1.5 cm could be seen on the spin-echo images. NMR imaging shows promise for assessment of benign and malignant mediastinal, hilar, and lung abnormalities

  14. Magnetic resonance cisternography; Magnetresonanz-Zisternographie

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, U. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg-Saar (Germany)

    2018-02-15

    Conventional MRI can be insufficient to depict certain pathologies of the cerebrospinal fluid (CSF)-filled spaces. 3-D T2-weighted sequences and phase-contrast imaging have a high sensitivity for pathologies of the CSF-filled spaces, but are susceptible to artifacts in some cases. Magnetic resonance (MR) cisternography directly depicts the connection between CSF-filled spaces. (orig.) [German] Bei bestimmten Fragestellungen, die Pathologien des Liquorraums betreffen, kann die konventionelle MRT-Bildgebung an ihre Grenzen stossen. Duennschichtige 3-D-T2-Sequenzen und die Phasenkontrastbildgebung koennen die Liquorraeume und den Liquorfluss mit hoher Aufloesung darstellen, sind aber zum Teil anfaellig fuer Artefakte. Die Magnetresonanz(MR)-Zisternographie erlaubt die genaue Darstellung des Liquorraums und stellt Verbindungen einzelner Kompartimente direkt dar. (orig.)

  15. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  16. Magnetic resonance imaging of pancreatitis: An update

    Science.gov (United States)

    Manikkavasakar, Sriluxayini; AlObaidy, Mamdoh; Busireddy, Kiran K; Ramalho, Miguel; Nilmini, Viragi; Alagiyawanna, Madhavi; Semelka, Richard C

    2014-01-01

    Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up examinations. Additional advantages include the ability to detect early forms of chronic pancreatitis and to better differentiate adenocarcinoma from focal chronic pancreatitis. This review addresses new trends in clinical pancreatic MR imaging emphasizing its role in imaging all types of acute and chronic pancreatitis, pancreatitis complications and other important differential diagnoses that mimic pancreatitis. PMID:25356038

  17. Maximum Likelihood Reconstruction for Magnetic Resonance Fingerprinting.

    Science.gov (United States)

    Zhao, Bo; Setsompop, Kawin; Ye, Huihui; Cauley, Stephen F; Wald, Lawrence L

    2016-08-01

    This paper introduces a statistical estimation framework for magnetic resonance (MR) fingerprinting, a recently proposed quantitative imaging paradigm. Within this framework, we present a maximum likelihood (ML) formalism to estimate multiple MR tissue parameter maps directly from highly undersampled, noisy k-space data. A novel algorithm, based on variable splitting, the alternating direction method of multipliers, and the variable projection method, is developed to solve the resulting optimization problem. Representative results from both simulations and in vivo experiments demonstrate that the proposed approach yields significantly improved accuracy in parameter estimation, compared to the conventional MR fingerprinting reconstruction. Moreover, the proposed framework provides new theoretical insights into the conventional approach. We show analytically that the conventional approach is an approximation to the ML reconstruction; more precisely, it is exactly equivalent to the first iteration of the proposed algorithm for the ML reconstruction, provided that a gridding reconstruction is used as an initialization.

  18. Optimal experiment design for magnetic resonance fingerprinting.

    Science.gov (United States)

    Bo Zhao; Haldar, Justin P; Setsompop, Kawin; Wald, Lawrence L

    2016-08-01

    Magnetic resonance (MR) fingerprinting is an emerging quantitative MR imaging technique that simultaneously acquires multiple tissue parameters in an efficient experiment. In this work, we present an estimation-theoretic framework to evaluate and design MR fingerprinting experiments. More specifically, we derive the Cramér-Rao bound (CRB), a lower bound on the covariance of any unbiased estimator, to characterize parameter estimation for MR fingerprinting. We then formulate an optimal experiment design problem based on the CRB to choose a set of acquisition parameters (e.g., flip angles and/or repetition times) that maximizes the signal-to-noise ratio efficiency of the resulting experiment. The utility of the proposed approach is validated by numerical studies. Representative results demonstrate that the optimized experiments allow for substantial reduction in the length of an MR fingerprinting acquisition, and substantial improvement in parameter estimation performance.

  19. [Gastric magnetic resonance study (methods, semiotics)].

    Science.gov (United States)

    Stashuk, G A

    2003-01-01

    The paper shows the potentialities of gastric study by magnetic resonance imaging (MRI). The methodic aspects of gastric study have been worked out. The MRI-semiotics of the unchanged and tumor-affected wall of the stomach and techniques in examining patients with gastric cancer of various sites are described. Using the developed procedure, MRI was performed in 199 patients, including 154 patients with gastric pathology and 45 control individuals who had no altered gastric wall. Great emphasis is placed on the role of MRI in the diagnosis of endophytic (diffuse) gastric cancer that is of priority value in its morphological structure. MRI was found to play a role in the diagnosis of the spread of a tumorous process both along the walls of the stomach and to its adjacent anatomic structures.

  20. Magnetic resonance imaging of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Naito, Yasushi; Tamaki, Susumu; Kurata, Kyosuke; Honjo, Iwao; Nishimura, Kazumasa; Nakano, Yoshihisa

    1987-01-01

    Magnetic resonance imaging (MRI) of the nasopharynx, the eustachian tube and the middle ear was performed in nine patients with nasopharyngeal carcinoma. MRI revealed the extent of the tumor more clearly than CT (computed tomography) when the tumor was situated in the parapharyngeal space. But when the tumor extended superficially in the nasopharyngeal mucosa, its margin could not be identified clearly by either MRI or CT because of hypervascularity and long T1 and T2 of the nasopharyngeal mucosa. Seven of the nine patients had unilateral otitis media with effusion. Their eustachian tube ventilation function was evaluated by an inflation-deflation technique. Failure of active equalization of negative pressure applied to the middle ear was found to be a characteristic disorder of their eustachian tube ventilation function. This dysfunction seemed to be correlated with the lateral dislocation of the eustachian tube cartilage caused by the tumor. (author)

  1. Magnetic resonance imaging of thoracic hydatid disease

    International Nuclear Information System (INIS)

    Sinner, W.N. von; Rifal, A.; Te Strake, L.; Sieck, J.; King Faisal Specialist Hospital and Research Centre, Riyadh; Michigan Univ., Ann Arbor

    1990-01-01

    Two patients with thoracic manifestations of hydatid disease (HD) are discussed; one patient had recurrent HD of the chest wall and the other, intrapulmonary HD after rupture and intrathoracic extension of an infradiaphragmatic cyst. At magnetic resonance (MR) imaging the manifestations of HD in the thorax are similar to previously reported MR findings in HD in the liver. The presence of a low signal intensity rim on T2 weighted images representing the cyst wall was confirmed. On T1 weighted images cysts with heterogeneous low and intermediate signal intensity contents and a relatively high signal intensity wall were seen. ''Folded parasitic membranes'' previously not described on MR were noted. Daughter cysts may have a low or high signal intensity depending on contents. Reactive changes in the lung may be quite marked compared with the liver, due to reaction to the parasite or simply because the lung is more easily compressed leading to secondary atelectasis. (orig.)

  2. Magnetic resonance imaging of spinal plasmacytoma

    International Nuclear Information System (INIS)

    Shah, B.K.; Saifuddin, A.; Price, G.J.

    2000-01-01

    AIM: To describe the magnetic resonance imaging (MRI) features of spinal plasmacytoma. MATERIALS AND METHODS: The clinical records and MRI findings in six patients (five men, one woman; age range 41-61 years) with histologically proven plasmacytoma of the spine were reviewed. All studies included sagittal T1- and T2-weighted spin-echo sequences and axial T1-weighted spin-echo sequences. Intravenous gadolinium DTPA was administered in four cases. RESULTS: MRI showed a characteristic appearances in four cases of low signal intensity curvilinear areas within the vertebra or cortical irregularity. CONCLUSION: Recognition of these imaging features can initiate the appropriate investigation as the commonest differential diagnosis for such lesions is metastasis. Shah, B. K. (2000)

  3. Multifunctional magnetic resonance imaging of cerebrovascular disease

    International Nuclear Information System (INIS)

    Grond, J. van der; Mali, W.P.T.M.

    1998-01-01

    Over the last few years magnetic resonance imaging (MRI) has developed into a multipurpose imaging technique. In addition to anatomical information, data can be obtained on perfusion, metabolism and imaging of the vascular anatomy. Especially in the field of neuroradiology the possibilities for obtaining multifunctional information from combined MR examinations are promising. In particular, stroke or stroke-related research benefits from these developments. This article reviews the current status and the potential of newly developed MR techniques with regard to the intracranial hemodynamic changes in patients with severe stenosis or occlusion of the internal carotid artery. The combination of MR angiography, perfusion-weighted MRI and MR spectroscopic imaging seems especially useful in the management of the individual patient. (orig.)

  4. Magnetic resonance tomography and ultrasound in rheumatology

    International Nuclear Information System (INIS)

    Kainberger, F.; Czerny, C.; Trattnig, S.; Lack, W.; Machold, K.; Graninger, W.

    1996-01-01

    Technical innovations and software improvements in magnetic resonance imaging (MRI) and high-resolution sonography (US) have definitely influenced the diagnostic imaging of rheumatic diseases. For MRI, improvements in surface coils, dedicated low-field systems (0.2 T), and software improvements (shorter acquisition times and refinements of fat suppressing techniques) must be mentioned. For sonography, the main innovations concern the development of higher transducer frequencies (7-15 Mhz) and power Doppler imaging. Clinical evaluations have shown that MRI and US are most useful in cases of suspected rheumatic disease with negative plain film radiographs and for documenting the course of the disease, diagnosing of early rheumatoid arthritis, making a differential diagnosis in clinically unclear rheumatic diseases, investigating vascularization, and quantifying pannus formation. In order to improve diagnostic efficacy the role of MRI and US in the management of patients with rheumatic disease should be reconsidered. (orig.) [de

  5. Magnetic resonance imaging of hypothalamic hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Junichi; Uozumi, Tohru; Sakoda, Katsuaki; Yamanaka, Masami; Kihara, Mikio; Nishi, Yoshikazu; Kagawa, Yoshihiro; Kajima, Toshio.

    1988-05-01

    Magnetic resonance (MR) findings of two patients with a hypothalamic hamartoma are discussed. The two girls showed clinical symptoms and endocrinological signs of precocious puberty. MR imaging was of diagnostic value superior to that of CT in the demonstration of the characteristic location of this tumor and relationships to the neighboring structures because of its multi-dimensional utility. Although it has been reported that CT showed this lesion as isodense to the grey matter with and without injection of contrast medium, MR imaging depicted the lesion as a high signal intensity area on T2-weighted images in both patients. MR imaging is a useful method for the evaluation of the hypothalamic hamartoma.

  6. Magnetic resonance. Gamma Rays in cardiology laboratories

    International Nuclear Information System (INIS)

    Lombardi, M.

    2001-01-01

    In recent years Cardiologists have shown an increasing interest on the use of Magnetic Resonance Imaging (MRI) for assessing cardiovascular diseases. The first generation of MRI equipment dedicated to cardiology is now available. The MRI Laboratory of Clinical Physiology Institute in Pisa has joined a multi-centric international project for the development of prototype of this dedicated machine and is currently involved in several subprojects such as the study of myocardial perfusion and the assessment of congenital heart diseases. An interdisciplinary group (cardiologists, software and hardware engineers, biologists, etc.) is full time involved in the development of new analysis algorithms, etc. The new concept of installing a MRI machine within clinical cardiovascular department has started to induce fruitful cooperations either in the research field or in the clinical setting [it

  7. Valuation for magnetic resonance of neuro tuberculosis

    International Nuclear Information System (INIS)

    Bolivar c, Guillermo; Delgado, Jorge A; Toro Nancy

    1997-01-01

    The increased incidence of neuro tuberculosis (NTB), due to the world epidemic of resistant strains and AIDS, has made of magnetic resonance (MR) imaging the study of choice for the early detection of lesions that lead the clinicians to an effective treatment. We present our experience with six cases of NTB, with meningoencephalic (4 cases), spinal, (1 case) and epidural (1 case) involvement. We identified basal arachnoiditis that was also seen on CT. Two cases demonstrated non-classifying tuberculomas, the spinal lesion consisted of casseifying tuberculoma that responded to treatment and disappeared on a follow up MR study. Epidural involvement consisted of Pott's disease with displacement and edema of the spinal cord. The differential diagnosis of these lesions includes mycoses, cysticercosis, sarcoidosis and leptomeningeal metastases

  8. Magnetic resonance imaging of intraorbital tumors

    International Nuclear Information System (INIS)

    Inoue, Tooru; Fukui, Masashi; Matsushima, Toshio; Fujii, Kiyotaka; Hasuo, Kanehiro

    1991-01-01

    Ten cases of histologically confirmed intraorbital tumors were studied with magnetic resonance imaging (MRI). Two meningiomas were nearly isointense on the T 1 -weighted image (T 1 WI) and the T 2 -weighted image (T 2 WI) relative on the cerebral cortex. The hemangiopericytoma, lacrimal gland tumor, optic glioma, and encephalocele were hypointense on the T 1 WI. The pseudotumor was hypoisointense on both the T 1 WI and the T 2 WI. The metastatic tumor (prostatic carcinoma) was hyperintense on both the T 1 WI and the T 2 WI. Gd-DTPA MRI was performed in five cases. The anatomical relationships between the tumor and the orbital tissue could be discriminated well by means of the coronal and sagittal views. MRI is thus found to be useful for the preoperative diagnosis of the intraorbital tumor and the selection of the surgical approach. (author)

  9. Magnetic resonance imaging of intraorbital tumors

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Tooru; Fukui, Masashi; Matsushima, Toshio; Fujii, Kiyotaka; Hasuo, Kanehiro (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1991-12-01

    Ten cases of histologically confirmed intraorbital tumors were studied with magnetic resonance imaging (MRI). Two meningiomas were nearly isointense on the T[sub 1]-weighted image (T[sub 1]WI) and the T[sub 2]-weighted image (T[sub 2]WI) relative on the cerebral cortex. The hemangiopericytoma, lacrimal gland tumor, optic glioma, and encephalocele were hypointense on the T[sub 1]WI. The pseudotumor was hypoisointense on both the T[sub 1]WI and the T[sub 2]WI. The metastatic tumor (prostatic carcinoma) was hyperintense on both the T[sub 1]WI and the T[sub 2]WI. Gd-DTPA MRI was performed in five cases. The anatomical relationships between the tumor and the orbital tissue could be discriminated well by means of the coronal and sagittal views. MRI is thus found to be useful for the preoperative diagnosis of the intraorbital tumor and the selection of the surgical approach. (author).

  10. Magnetic resonance imaging of traumatic cervical injury

    International Nuclear Information System (INIS)

    Juhng, S. K.; Lee, K. S.; Sohn, K. J.; Choi, S. S.; Won, J. J.

    1994-01-01

    To evaluate magnetic resonance imaging (MRI) findings of cevical injuries. MRI studies of 34 patients with cervical spinal injuries were analyzed retrospectively. All MRI scans were obtained with an 1.0T superconductive MRI scanner (Siemens Magnetom 42SPE) and their findings were analyzed regarding the spinal cord, bony spine, ligaments, and intervertebral disks. A variety of abnormal findings were detected: 25 cord abnormalities including cord compression (15 cases), cord edema (4 cases), syringomyelia (4 cases), myelomalacia (1 case), and hemorrhagic contusion (1 case), 18 ligamentous injuries, 22 disk herniations (9 post-traumatic, 13 chronic degenerative), 11 spine fractures, and 4 subluxations. MRI is useful in evaluating the spinal cord itself, in depicting ligamentous injuries, in establishing the presence of disc herniation, and in assessing the alignment of cervical spine

  11. Clinical application of magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Murakami, Akihiko; Onoe, Teruyuki; Kodera, Akifumi; Ohtsuki, Tetsuya; Shiomi, Akio; Ida, Masaaki; Sawada, Takahisa

    1999-01-01

    We performed the magnetic resonance coronary angiography (MRCA) in the cases which underwent coronary angiography (CAG) and obtained images were compared. Lesion with significant constriction more than 75% on CAG were determined as abnormal findings on MRCA, however, lesions with about 50% constriction were as the normal findings. On the assessment of the re-constriction after PTCA, the changes in signal were found in about half of cases. This may come from the contribution of flexion lesions, the difficulty to assess moderate constriction after PTCA, etc. For the anomalous aortic origin of coronary artery, peripheral large vessels could be simultaneously imaged by MRCA and be also assessed among their clear spatial relationship. Although MRCA has some problems on the assessment for flexion or moderate constriction, these results suggested that MRCA is useful to clinical application as the non-invasive examination. (K.H.)

  12. Magnetic resonance imaging of traumatic cervical injury

    Energy Technology Data Exchange (ETDEWEB)

    Juhng, S. K.; Lee, K. S.; Sohn, K. J.; Choi, S. S.; Won, J. J. [Wonkwang University School of Medicine, Iri (Korea, Republic of)

    1994-04-15

    To evaluate magnetic resonance imaging (MRI) findings of cevical injuries. MRI studies of 34 patients with cervical spinal injuries were analyzed retrospectively. All MRI scans were obtained with an 1.0T superconductive MRI scanner (Siemens Magnetom 42SPE) and their findings were analyzed regarding the spinal cord, bony spine, ligaments, and intervertebral disks. A variety of abnormal findings were detected: 25 cord abnormalities including cord compression (15 cases), cord edema (4 cases), syringomyelia (4 cases), myelomalacia (1 case), and hemorrhagic contusion (1 case), 18 ligamentous injuries, 22 disk herniations (9 post-traumatic, 13 chronic degenerative), 11 spine fractures, and 4 subluxations. MRI is useful in evaluating the spinal cord itself, in depicting ligamentous injuries, in establishing the presence of disc herniation, and in assessing the alignment of cervical spine.

  13. Magnetic resonance imaging of the genitourinary tract

    International Nuclear Information System (INIS)

    Strake, L. te; Persijn van Meerten, E.L. van; Trimbos, J.B.M.Z.; Paul, L.C.; Langeveld, J.W.; Bloem, J.L.; Bluemm, R.G.; Doornbos, J.

    1986-01-01

    This is an overview of the current applications of magnetic resonance imaging (MRI) in the genitourinary tract based on the experience with the 0.5-Tesla MR scanner (Gyroscan, Philips) at the Leiden University Hospital and on reports in the literature. MRI appears to share some of the limitations of CT. MRI cannot reliably differentiate between a malignant and a benign tumor. In the staging of ovarian malignancies by means of MRI, bowel preparation would be desirable. On the other hand, the soft-tissue contrast resolution of MRI is superior to that of CT and images can be obtained in any plane. Thus MRI promises to be an accurate method for staging malignancies. The results in the examination of transplant kidneys are encouraging. It is expected that there will be a place for MRI as a complementary technique to ultrasonography in the diagnosis of scrotal disease. (Auth.)

  14. Magnetic resonance imaging of facial muscles

    Energy Technology Data Exchange (ETDEWEB)

    Farrugia, M.E. [Department of Clinical Neurology, University of Oxford, Radcliffe Infirmary, Oxford (United Kingdom)], E-mail: m.e.farrugia@doctors.org.uk; Bydder, G.M. [Department of Radiology, University of California, San Diego, CA 92103-8226 (United States); Francis, J.M.; Robson, M.D. [OCMR, Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford (United Kingdom)

    2007-11-15

    Facial and tongue muscles are commonly involved in patients with neuromuscular disorders. However, these muscles are not as easily accessible for biopsy and pathological examination as limb muscles. We have previously investigated myasthenia gravis patients with MuSK antibodies for facial and tongue muscle atrophy using different magnetic resonance imaging sequences, including ultrashort echo time techniques and image analysis tools that allowed us to obtain quantitative assessments of facial muscles. This imaging study had shown that facial muscle measurement is possible and that useful information can be obtained using a quantitative approach. In this paper we aim to review in detail the methods that we applied to our study, to enable clinicians to study these muscles within the domain of neuromuscular disease, oncological or head and neck specialties. Quantitative assessment of the facial musculature may be of value in improving the understanding of pathological processes occurring within facial muscles in certain neuromuscular disorders.

  15. Magnetic resonance imaging of facial muscles

    International Nuclear Information System (INIS)

    Farrugia, M.E.; Bydder, G.M.; Francis, J.M.; Robson, M.D.

    2007-01-01

    Facial and tongue muscles are commonly involved in patients with neuromuscular disorders. However, these muscles are not as easily accessible for biopsy and pathological examination as limb muscles. We have previously investigated myasthenia gravis patients with MuSK antibodies for facial and tongue muscle atrophy using different magnetic resonance imaging sequences, including ultrashort echo time techniques and image analysis tools that allowed us to obtain quantitative assessments of facial muscles. This imaging study had shown that facial muscle measurement is possible and that useful information can be obtained using a quantitative approach. In this paper we aim to review in detail the methods that we applied to our study, to enable clinicians to study these muscles within the domain of neuromuscular disease, oncological or head and neck specialties. Quantitative assessment of the facial musculature may be of value in improving the understanding of pathological processes occurring within facial muscles in certain neuromuscular disorders

  16. Geochemical Controls on Nuclear Magnetic Resonance Measurements

    International Nuclear Information System (INIS)

    Knight, Rosemary; Prasad, Manika; Keating, Kristina

    2003-01-01

    OAK-B135 Our research objectives are to determine, through an extensive set of laboratory experiments, the effect of the specific mineralogic form of iron and the effect of the distribution of iron on proton nuclear magnetic resonance (NMR) relaxation mechanisms. In the first nine months of this project, we have refined the experimental procedures to be used in the acquisition of the laboratory NMR data; have ordered, and conducted preliminary measurements on, the sand samples to be used in the experimental work; and have revised and completed the theoretical model to use in this project. Over the next year, our focus will be on completing the first phase of the experimental work where the form and distribution of the iron in the sands in varied

  17. Magnetic resonance imaging of placenta accreta

    Science.gov (United States)

    Varghese, Binoj; Singh, Navdeep; George, Regi A.N; Gilvaz, Sareena

    2013-01-01

    Placenta accreta (PA) is a severe pregnancy complication which occurs when the chorionic villi (CV) invade the myometrium abnormally. Optimal management requires accurate prenatal diagnosis. Ultrasonography (USG) and magnetic resonance imaging (MRI) are the modalities for prenatal diagnosis of PA, although USG remains the primary investigation of choice. MRI is a complementary technique and reserved for further characterization when USG is inconclusive or incomplete. Breath-hold T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) and balanced steady-state free precession imaging in the three orthogonal planes is the key MRI technique. Markedly heterogeneous placenta, thick intraplacental dark bands on half-Fourier acquisition single-shot turbo spin-echo (HASTE), and disorganized abnormal intraplacental vascularity are the cardinal MRI features of PA. MRI is less reliable in differentiating between different degrees of placental invasion, especially between accreta vera and increta. PMID:24604945

  18. Magnetic resonance imaging of placenta accreta

    Directory of Open Access Journals (Sweden)

    Binoj Varghese

    2013-01-01

    Full Text Available Placenta accreta (PA is a severe pregnancy complication which occurs when the chorionic villi (CV invade the myometrium abnormally. Optimal management requires accurate prenatal diagnosis. Ultrasonography (USG and magnetic resonance imaging (MRI are the modalities for prenatal diagnosis of PA, although USG remains the primary investigation of choice. MRI is a complementary technique and reserved for further characterization when USG is inconclusive or incomplete. Breath-hold T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE and balanced steady-state free precession imaging in the three orthogonal planes is the key MRI technique. Markedly heterogeneous placenta, thick intraplacental dark bands on half-Fourier acquisition single-shot turbo spin-echo (HASTE, and disorganized abnormal intraplacental vascularity are the cardinal MRI features of PA. MRI is less reliable in differentiating between different degrees of placental invasion, especially between accreta vera and increta.

  19. Magnetic resonance imaging of placenta accreta

    International Nuclear Information System (INIS)

    Varghese, Binoj; Singh, Navdeep; George, Regi A.N; Gilvaz, Sareena

    2013-01-01

    Placenta accreta (PA) is a severe pregnancy complication which occurs when the chorionic villi (CV) invade the myometrium abnormally. Optimal management requires accurate prenatal diagnosis. Ultrasonography (USG) and magnetic resonance imaging (MRI) are the modalities for prenatal diagnosis of PA, although USG remains the primary investigation of choice. MRI is a complementary technique and reserved for further characterization when USG is inconclusive or incomplete. Breath-hold T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) and balanced steady-state free precession imaging in the three orthogonal planes is the key MRI technique. Markedly heterogeneous placenta, thick intraplacental dark bands on half-Fourier acquisition single-shot turbo spin-echo (HASTE), and disorganized abnormal intraplacental vascularity are the cardinal MRI features of PA. MRI is less reliable in differentiating between different degrees of placental invasion, especially between accreta vera and increta

  20. Magnetic resonance imaging of nasopharyngeal malignant tumors

    International Nuclear Information System (INIS)

    Sakakihara, Junji; Kanoh, Naoyuki; Hayakawa, Katsumi.

    1988-01-01

    Magnetic Resonance Imaging (MRI) was used in the examination of three patients with nasopharyngeal malignant tumor and cranial nerve symptoms. Coronal and saggital sections were very useful for determining skull base invasion. Its high contrast resolution enabled us to visualize several cranial nerves directly. Differentiation between tumor and effusion in the paranasal sinuses was easy especially in T2 weighted images. Bone destruction could also be detected as bone marrow replacement by tumor or as interruption of the black line of compact bone. Local relationships of tumor and large blood vessels were visualized by MRI without invasive contrast enhancing methods. Despite such advantages, in one patient whose symptoms were highly suggestive of cranial invasion, no cranial invasion was detected by CT or MRI. (author)