WorldWideScience

Sample records for longitudinal film badge

  1. The response of film badge dosemeters to high energy photon radiation

    International Nuclear Information System (INIS)

    Playle, T.S.

    1988-12-01

    The sites of the earlier magnox reactor power stations at Berkeley and Bradwell in the United Kingdom are subject to 6 MeV photon radiation from the coolant gas. Since 1966 the Central Electricity Generating Board has included in its film badge personal dosimetry procedures an algorithm for applying a correction for over-response to high energy photon radiation. The correction is based on laboratory irradiations using a source of pure 6 MeV photon radiation. Recently, the opportunity arose to evaluate the response of the film badges at locations around the Berkeley reactors where spectrum-dependent dose equivalent rates had been measured. This report compares the response of the film badge in these characterised radiation environments with the response measured in the calibration laboratory. It is concluded that in the location where measurements were made, the high energy enhancement of measured dose was obscured by the effects of low energy scattered radiation, and it is considered that this will be the case for all practical situations on the power station site. There is therefore no advantage in using the 6 MeV correction factors for routine film badge dosimetry in these locations. (author)

  2. Low-level dosimetry based on activation analysis of badge film, 1

    International Nuclear Information System (INIS)

    Morikawa, Kaoru; Yamashita, Kazuya; Inamoto, Kazuo; Maeda, Masayuki; Sato, Takashi; Ono, Koichi.

    1988-01-01

    Underexposed badge film contains a minor quantity of silver which corresponds to the low radiation dose even after completion of the photographic densitometry ; however, it cannot be detected with a photographic densitometer. We intended to clarify the minor silver content based on radioactivation analysis with thermal neutrons at KUR (Kyoto University Research Reactor). The natural silver consists of two stable nuclides, i.e., 107 Ag and 109 Ag. These can be activated with irradiation of thermal neutrons to two radionuclides, i.e., 108 Ag and 110 Ag. In this paper, through the activation analysis of an underexposed badge film, methods of measurements are shown regarding both 108 Ag produced by the 107 Ag (n, γ) reaction and 110 Ag by the 109 Ag (n, γ). After underexposed badge films were irradiated with thermal neutrons, some gamma-rays emitted from the radionuclides in the activated films were measured with a high pure Ge detector or a NaI (Tl) scintillation detector. The following results were obtained: (1) several elements such as silver, iodine, gold, antimony, manganese and copper were detected by activation analyses of films exposed to low level 60 Co gamma-rays, (2) the exposure vs 108 Ag or 110 Ag activity curve was linear in the lower dose range of 60 Co gamma-rays. These data indicate that low level radiation doses, which is indeterminable by ordinary photographic densitometry, can be estimated by activation analysis of silver atoms in badge films. (author)

  3. The Dose Estimation Formula Of Photon Radiation To Film Badge Of Kodak Type 2

    International Nuclear Information System (INIS)

    Rohmah, Nur

    2000-01-01

    Study to determine the formula of dose estimation for photon radiation to film badge of Kodak type 2 has been carried out. The irradiation was done by irradiated film badge of Kodak type 2 using photon sources of X-rays machine, 137 Cs and 60 Co. By determining the apparent dose and also the sensitivity values each filters of the calibration curve and the weighting factors of energy dependence curve, the formula of the dose estimation for film badge of Kodak type 2 could be obtained, i.e. H 1cm 2.066761E-02N ADPI-2 + 1.953342N ADAI - 8.946254N ADCu + 24.80611N ADSn/pb

  4. Stratified dosimetric badge

    International Nuclear Information System (INIS)

    Cox, F.M.; Shoffner, B.M.; Chamberlain, J.D.; Shrader, E.F.

    1974-01-01

    That badge is of the type comprising a perforated rigid supporting member of nonluminescent matter and a film-like non-luminescent foil rendered pervious to light according to the code and mounted so as to be in register with holes in the supporting member. The badge is characterized in that it comprises a depressed portion in the upper surface of the supporting member, the lower/surface of which is correspondingly bulged, in that the peripherical edges of the supporting member extend vertically downwards beyond said depressed portion, in that one or several ports in each of which a dosimeter is fixed are provided in said bulged portion, and in the said film-like foil is fixed within the peripheral edges of the supporting member, so that the badge lower surface to which said film-like foil is fixed comprises a planar surface. That badge can be used in particular for checking radiations to which individuals have been exposed [fr

  5. Measurement error in longitudinal film badge data

    International Nuclear Information System (INIS)

    Marsh, J.L.

    2002-04-01

    The classical measurement error model is that of a simple linear regression with unobservable variables. Information about the covariates is available only through error-prone measurements, usually with an additive structure. Ignoring errors has been shown to result in biased regression coefficients, reduced power of hypothesis tests and increased variability of parameter estimates. Radiation is known to be a causal factor for certain types of leukaemia. This link is mainly substantiated by the Atomic Bomb Survivor study, the Ankylosing Spondylitis Patients study, and studies of various other patients irradiated for therapeutic purposes. The carcinogenic relationship is believed to be a linear or quadratic function of dose but the risk estimates differ widely for the different studies. Previous cohort studies of the Sellafield workforce have used the cumulative annual exposure data for their risk estimates. The current 1:4 matched case-control study also uses the individual worker's film badge data, the majority of which has been unavailable in computerised form. The results from the 1:4 matched (on dates of birth and employment, sex and industrial status) case-control study are compared and contrasted with those for a 1:4 nested (within the worker cohort and matched on the same factors) case-control study using annual doses. The data consist of 186 cases and 744 controls from the work forces of four BNFL sites: Springfields, Sellafield, Capenhurst and Chapelcross. Initial logistic regressions turned up some surprising contradictory results which led to a re-sampling of Sellafield mortality controls without the date of employment matching factor. It is suggested that over matching is the cause of the contradictory results. Comparisons of the two measurements of radiation exposure suggest a strongly linear relationship with non-Normal errors. A method has been developed using the technique of Regression Calibration to deal with these in a case-control study context

  6. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  7. Detection of narcotics with an immunoassay film badge

    International Nuclear Information System (INIS)

    Lukens, H.R.

    1993-01-01

    Efficient personnel performance, a major requirement for a safe nuclear industry, is jeopardized where personnel use narcotics. However, detection of narcotics at nuclear plants is a challenge. The unique specificity and sensitivity of an immunoassay has been implemented in the form of a small, dry immunoassay film badge (IFB) for the detection of vapors emitted by narcotics. The device is suitable as an area monitor, and its characteristics are suitable for use as a breath monitor for the detection of drug use

  8. User's guide for survey-meter- and film-badge-dosimetry data bases

    International Nuclear Information System (INIS)

    Phillips, W.G.; Sherman, S.; Young, R.

    1981-05-01

    This manual describes the data storage and retrieval system designed by Environmental Monitoring Systems Laboratory Las Vegas (EMSL-LV) for radiation exposure data recorded in offsite areas during and after nuclear weapons tests conducted at the Nevada Test Site in the 1950's and early 1960's. Referred to hereinafter as the EMSL-LV system, this system contains two distinct subsets of offsite radiological measurements collected during early nuclear atmospheric tests at the Nevada Test Site. The purpose of the manual is to present the methods for using the EMSL-LV system to examine all or any portion of either data subset. The two distinct subsets which comprise the EMSL-LV system are survey meter data and film badge dosimetry data. The survey meter data consist of readings obtained from portable radiation monitoring instruments used around the Nevada Test Site during the 1950's and early 1960's to measure radiation exposure rates resulting from the nuclear testing program. The dosimetry data consist of measurements of integrated radiation exposure made with film badge type dosimeters in areas surrounding the Nevada Test Site

  9. Accuracy of effective dose estimation in personal dosimetry: a comparison between single-badge and double-badge methods and the MOSFET method.

    Science.gov (United States)

    Januzis, Natalie; Belley, Matthew D; Nguyen, Giao; Toncheva, Greta; Lowry, Carolyn; Miller, Michael J; Smith, Tony P; Yoshizumi, Terry T

    2014-05-01

    The purpose of this study was three-fold: (1) to measure the transmission properties of various lead shielding materials, (2) to benchmark the accuracy of commercial film badge readings, and (3) to compare the accuracy of effective dose (ED) conversion factors (CF) of the U.S. Nuclear Regulatory Commission methods to the MOSFET method. The transmission properties of lead aprons and the accuracy of film badges were studied using an ion chamber and monitor. ED was determined using an adult male anthropomorphic phantom that was loaded with 20 diagnostic MOSFET detectors and scanned with a whole body CT protocol at 80, 100, and 120 kVp. One commercial film badge was placed at the collar and one at the waist. Individual organ doses and waist badge readings were corrected for lead apron attenuation. ED was computed using ICRP 103 tissue weighting factors, and ED CFs were calculated by taking the ratio of ED and badge reading. The measured single badge CFs were 0.01 (±14.9%), 0.02 (±9.49%), and 0.04 (±15.7%) for 80, 100, and 120 kVp, respectively. Current regulatory ED CF for the single badge method is 0.3; for the double-badge system, they are 0.04 (collar) and 1.5 (under lead apron at the waist). The double-badge system provides a better coefficient for the collar at 0.04; however, exposure readings under the apron are usually negligible to zero. Based on these findings, the authors recommend the use of ED CF of 0.01 for the single badge system from 80 kVp (effective energy 50.4 keV) data.

  10. Film badge personnel monitoring and dose distribution of industrial and medical workers in the country (1994-1998)

    International Nuclear Information System (INIS)

    Mittal, Hariom; Pandey, R.L.; Massand, O.P.

    2001-03-01

    Personnel Monitoring Section, Bhabha Atomic Research Centre, Mumbai, is entrusted with the responsibility of providing a countrywide personnel monitoring to radiation workers using extemal radiation like X, beta, gamma and neutron. As per Radiation Protection Rules (RPR) of 1971 promulgated by the competent authority the personnel monitoring service is mandatory for all the workers working with radiation. The radiation exposures received by them should be within the limits stipulated by AERB. Nearly 43,000 radiation workers in about 3000 DAE and non DAE institutions using radiation and radioisotopes are monitored, using both the Film Badges and the Thermoluminescent dosimeters. This report presents various aspects of film dosimetry which was introduced more than four decades ago in the country and also analysis of doses received by the radiation workers in the five year block 1994-1998 covered by film badge service. (author)

  11. Are Badges Useful in Education?: It Depends upon the Type of Badge and Expertise of Learner

    Science.gov (United States)

    Abramovich, Samuel; Schunn, Christian; Higashi, Ross Mitsuo

    2013-01-01

    Educational Badges are touted as an alternative assessment that can increase learner motivation. We considered two distinct models for educational badges; merit badges and videogame achievements. To begin unpacking the relationship between badges and motivation, we conducted a study using badges within an intelligent-tutor system for teaching…

  12. Open badges for education: what are the implications at the intersection of open systems and badging?

    Directory of Open Access Journals (Sweden)

    June Ahn

    2014-08-01

    Full Text Available Badges have garnered great interest among scholars of digital media and learning. In addition, widespread initiatives such as Mozilla’s Open Badge Framework expand the potential of badging into the realm of open education. In this paper, we explicate the concept of open badges. We highlight some of the ways that researchers have examined badges as part of educational practice and also highlight the different definitions of open-ness that are employed in popular and scholarly thought. By considering badges from three different perspectives (motivation, pedagogy, and credential and the concept of openness from three different perspectives (production, access and appropriation we develop a framework to consider the tensions where these competing conceptions meet. This explication illuminates how the ideas of open and badges intersect, and clarifies situations where these concepts come into direct conflict or mutually enhance each other. Our analysis pinpoints and elucidates particular areas where research is needed to better understand the complex phenomenon of open badges, and also offers design considerations for developers, educators, and organizations that are actively involved in open badges.

  13. Badging people not on your payroll.

    Science.gov (United States)

    Hogan, Mary Alice

    2009-01-01

    A complex badging process to create a culture of safety in a medical center is described by the author. Badging is not only used to control access by employees, but non-employees--medical students, vendors, contractors, volunteers, etc.--are subjected to similar processing procedures before they can be issued badges.

  14. Digital Badges in Education

    Science.gov (United States)

    Gibson, David; Ostashewski, Nathaniel; Flintoff, Kim; Grant, Sheryl; Knight, Erin

    2015-01-01

    Digital badges provide new affordances for online educational activities and experiences. When used with points and leaderboards, a badge can become a gamification element allowing learners to compete with themselves or others, and to know how close they are to accomplishing a goal and acquiring its accompanying reputation. In this role, badges…

  15. Passive Badge Assessment for Long-Term, Low-level Air Monitoring on Submarines: Acrolein Badge Validation

    National Research Council Canada - National Science Library

    Williams, Kimberly P; Rose-Pehrsson, Susan L; Kidwell, David A

    2006-01-01

    .... Passive badge monitors for acrolein detection were tested. Long-term sampling efficiency was evaluated for a 28-day period by comparing the response of the passive badge to an active tube sampling method...

  16. Measurement of the external doses at low and high exposures by Agfa personal monitoring film, FD-III-B badge

    International Nuclear Information System (INIS)

    Mihai, F.; Stochioiu, A.; Bercea, S.; Udup, E.; Tudor, I.

    2008-01-01

    Full text: A growing number of papers report occupational exposure monitoring by different dosemeter devices. Researches into improvement of the personal dosemeter systems are encouraged. Dose measurement and especially skin dose measurement, are therefore increasingly important. Methods and acceptable dosemeter are not clearly defined and differ from a dosimetry laboratory to other depending on their specifically work procedure and type of dosemeter utilized. Taking into account the characteristic of the work place (industry, research, medical application) dosemeter have to cover a large dose range. The dose assessment problems are manly in low doses range (under 0.2 mSv) and higher doses range. For example, typical for radiation oncology and nuclear accident dosimetry the dose ranges are on the order of 2-70 Gy and 0.1-5 Gy. This work presents the performance of the Agfa personal monitoring film, badge FD-III-B type used in the most of the occupational exposure monitoring from Romania. The FD-III-B dosimeter, manufactured in Romania, is used for monitoring personnel working in radioactive environment - the photodosimetric method is the one of the most reliable method presenting the advantage that the film may be considered as master probe over 30 year and may be utilized during litigation. The dosimeter contains metallic filters of Al, Cu, Pb with different thicknesses, a plastic filter and a open window. The badge FD-III-B is a class B dosimeter according to the dose range and an indices 3 dosimeter from energy range of the radiations in conformity with Romanian Standard in force. Film Agfa 'personal monitoring', tacked in this experiment, consists of a low speed film (D2) and a very sensitive film (D10) designed for recording X-ray, gamma and beta radiation over the doses range 0.1 mSv to 1 Sv. The experiments have been effectuated at different background optical density (base fog) of the films and at different sources of radiation: 13 :7Cs, 60 Co and 24 : 1 Am

  17. CJEP will offer open science badges.

    Science.gov (United States)

    Pexman, Penny M

    2017-03-01

    This editorial announces the decision of the Canadian Journal of Experimental Psychology (CJEP) to offer Open Science Framework (OSF) Badges. The Centre for Open Science provides tools to facilitate open science practices. These include the OSF badges. The badges acknowledge papers that meet standards for openness of data, methods, or research process. They are now described in the CJEP Submission Guidelines, and are provided in the editorial. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. A new fully automated TLD badge reader

    International Nuclear Information System (INIS)

    Kannan, S.; Ratna, P.; Kulkarni, M.S.

    2003-01-01

    At present personnel monitoring in India is being carried out using a number of manual and semiautomatic TLD badge Readers and the BARC TL dosimeter badge designed during 1970. Of late the manual TLD badge readers are almost completely replaced by semiautomatic readers with a number of performance improvements like use of hot gas heating to reduce the readout time considerably. PC based design with storage of glow curve for every dosimeter, on-line dose computation and printout of dose reports, etc. However the semiautomatic system suffers from the lack of a machine readable ID code on the badge and the physical design of the dosimeter card not readily compatible for automation. This paper describes a fully automated TLD badge Reader developed in the RSS Division, using a new TLD badge with machine readable ID code. The new PC based reader has a built-in reader for reading the ID code, in the form of an array of holes, on the dosimeter card. The reader has a number of self-diagnostic features to ensure a high degree of reliability. (author)

  19. Engaging Undergraduate Students in a Co-Curricular Digital Badging Platform

    Science.gov (United States)

    Coleman, Jonathan D.

    2018-01-01

    Digital badging continues to garner attention in the educational community. What remains to be seen is how badging will interact with traditional curricular elements. While concerns have been raised about using badges as extrinsic motivators in coursework, there are alternate areas of application for digital badging. Badges may actually serve to…

  20. MOOC Badging and the Learning Arc

    OpenAIRE

    Cross, Simon; Galley, Rebecca

    2012-01-01

    The first part of the post expands on some of our thinking behind the digital badging strategy used in the 2012 OLDS MOOC by using a pictorial representation to explain the place of the badges in the course. This is predicated on (a) the idea that a course, just like a novel, a movie or a video game, contains a broad central 'story arc' - a 'learning arc' or journey with a start (beginning of course) and an end, and (b) the idea that there are different types of badge that have different rela...

  1. Occupational exposure from external radiation used in medical practices in Pakistan by film badge dosimetry

    International Nuclear Information System (INIS)

    Jabeen, A.; Munir, M.; Khalil, A.; Masood, M.; Akhter, P.

    2010-01-01

    Occupational exposure data of workers due to external sources of radiation in various medical practices such as nuclear medicine (NM), radiotherapy and diagnostic radiology (DR) in Pakistan were collected and analysed. Whole-body doses of workers were measured by film badge dosimetry technique during 2003-2007. Annual average effective dose in NM, radio-therapy and DR varied in the range of 1.39-1.80, 1.05-1.45 and 1.22-1.71 mSv, respectively, during 2003-2007. These values are quite low and well below the annual limit of 20 mSv averaged over a period of 5 consecutive years. Nobody received the radiation dose >50 mSv in any single year over a period of 5 consecutive years; therefore, no overexposure case has been detected. Decreasing trend of annual average dose values in aforementioned categories of work during 2003-2007 indicates the improvement of radiation protection status in medical field in Pakistan. (authors)

  2. Tweeting badges: user motivations for displaying achievement in publicly networked environments.

    Science.gov (United States)

    Kwon, K Hazel; Halavais, Alexander; Havener, Shannon

    2015-02-01

    Badge systems, a common mechanism for gamification on social media platforms, provide a way for users to present their knowledge or experience to others. This study aims to contribute to the understanding of why social media users publicize their achievements in the form of online badges. Five motivational factors for badge display in public networked environments are distinguished-self-efficacy, social incentives, networked support, passing time, and inattentive sharing-and it is suggested that different badge types are associated with different motivations. System developers are advised to consider these components in their designs, applying the elements most appropriate to the communities they serve. Comparing user motivations associated with badges shared across boundaries provides a better understanding of how online badges relate to the larger social media ecosystem.

  3. Using digital badges in South Africa informing the validation of a multi-channel open badge system at a German university

    CSIR Research Space (South Africa)

    Niehaus, E

    2017-05-01

    Full Text Available strategy, remains an area to explore. One of the most crucial points of concern currently with digital badging is how to validate or credit a competence or skillset and what value this validation will carry for the individual. The Mozilla digital badge...

  4. Badge Office Process Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Haurykiewicz, John Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dinehart, Timothy Grant [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Parker, Robert Young [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-12

    The purpose of this process analysis was to analyze the Badge Offices’ current processes from a systems perspective and consider ways of pursuing objectives set forth by SEC-PS, namely increased customer flow (throughput) and reduced customer wait times. Information for the analysis was gathered for the project primarily through Badge Office Subject Matter Experts (SMEs), and in-person observation of prevailing processes. Using the information gathered, a process simulation model was constructed to represent current operations and allow assessment of potential process changes relative to factors mentioned previously. The overall purpose of the analysis was to provide SEC-PS management with information and recommendations to serve as a basis for additional focused study and areas for potential process improvements in the future.

  5. Adding Badging to a Marketing Simulation to Increase Motivation to Learn

    Science.gov (United States)

    Saxton, M. Kim

    2015-01-01

    Badging has become a popular tool for obtaining social recognition for personal accomplishments. This innovation describes a way to add badging to a marketing simulation to increase student motivation to achieve the simulation's goals. Assessments indicate that badging both motivates students to perform better and helps explain students' perceived…

  6. Carrying an anti-nuclear-power badge in the teaching profession

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The carrying of an anti-nuclear-power badge by a teacher during school hours violates the order to practice reticence in political activities. At the beginning of 1977 some teachers, the plaintiff as well, carried anti-nuclear-power badges, i.e. a round badge with a stylized red sun on a yellow background with the inscription 'Nuclear power - No, thank you'. Following a general direction by the educational authorities, the headmistress forbade plaintiff on 4.11.77 to visibly carry this badge during lessons. This protest having been without success, action was brought with partial success at the Administrative and Higher Administrative Court. The Federal Administrative Court dismissed the case. (orig./HSCH) [de

  7. Student perceptions of digital badges in a drug information and literature evaluation course.

    Science.gov (United States)

    Fajiculay, Jay R; Parikh, Bhavini T; Wright, Casey V; Sheehan, Amy Heck

    2017-09-01

    The purpose of this article is to describe student perceptions of implementation of digital badges in a drug information and literature evaluation course. Two digital badges were developed as voluntary learning opportunities. Student perceptions were obtained through pre- and post-survey instruments consisting of selected questions from the Motivated Strategies for Learning Questionnaire. The response rate was 69% (106/153). At baseline, 53% of respondents agreed that digital badges could help them better understand course material. More students agreed they would share earned digital badges on LinkedIn (68%) than Facebook (19%). Most students who earned digital badges agreed that badges helped increase their confidence in course material (73%), focus on specific learning objectives (55%), look deeper into course competencies (64%), and were a useful adjunct to the traditional teaching method (82%). Digital badges were perceived by students as a positive adjunct to learning and may provide a novel mechanism for development of an electronic skills-based portfolio. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  9. Digital Badges and Library Instructional Programs: Academic Library Case Study

    Science.gov (United States)

    Rodgers, Andrea Reed; Puterbaugh, Mark

    2017-01-01

    This case study describes the planning, implementation, and migration process of Eastern University Library's information literacy digital badge. Prior to implementing a badging program, information literacy sessions were informally embedded in first-year college writing courses as a "one-shot" presentation. Spurred on by accreditation…

  10. Developing a conceptual model for facilitating the issuing of digital badges in a resource constrained environment

    CSIR Research Space (South Africa)

    Salerno, S

    2015-09-01

    Full Text Available Gamification and digital badging are new concepts to the educational environment, where on completion of specific tasks, an individual can earn a badge or badges showing their achievement. Currently Mozilla Open Badges is the standard...

  11. Comparing different error-conditions in film dosemeter evaluation

    International Nuclear Information System (INIS)

    Roed, H.; Figel, M.

    2007-01-01

    In the evaluation of a film used as a personal dosemeter it may be necessary to mark the dosemeters when possible error-conditions are recognised, such as errors that have an influence on the ability to make a correct evaluation of the dose value. In this project a comparison has been carried out to examine how two individual monitoring services, IMS [National Inst. of Radiation Hygiene (Denmark) (NIRH) and National Research Centre for Environment and Health (Germany) (GSF)], from two different EU countries mark their dosemeters. The IMS are different in size, type of customers and issuing period, but both use films as their primary dosemeters. The error-conditions examined are dosemeters exposed to moisture or light, contaminated dosemeters, films exposed outside the badge, missing filters in the badge, films inserted incorrectly in the badge and dosemeters not returned or returned too late to the IMS. The data are collected for the year 2003 where NIRH evaluated ∼50,000 and GSF ∼1.4 million film dosemeters. The percentage of film dosemeters is calculated for each error-condition as well as the distribution among eight different employee categories, i.e. medicine, nuclear medicine, nuclear industry, industry, radiography, laboratories, veterinary and others. It turned out, that incorrect insertion of the film in the badge was the most common error-condition observed at both IMS and that veterinarians, as the employee category, generally have the highest number of errors. NIRH has a significantly higher relative number of dosemeters in most error-conditions than GSF, which perhaps reflects that a comparison is difficult due to different systemic and methodical differences between the IMS and countries, e.g. regulations and monitoring programs etc. Also the non-existence of a common categorisation method for employee categories contributes to make a comparison like this difficult. (authors)

  12. Digital Badges for STEM Learning in Secondary Contexts: A Mixed Methods Study

    Science.gov (United States)

    Elkordy, Angela

    The deficit in STEM skills is a matter of concern for national economies and a major focus for educational policy makers. The development of Information and Communications Technologies (ICT) has resulted in a rapidly changing workforce of global scale. In addition, ICT have fostered the growth of digital and mobile technologies which have been the learning context, formal and informal, for a generation of youth. The purpose of this study was to design an intervention based upon a competency-based, digitally-mediated, learning intervention: digital badges for learning STEM habits of mind and practices. Designed purposefully, digital badge learning trajectories and criteria can be flexible tools for scaffolding, measuring, and communicating the acquisition of knowledge, skills, or competencies. One of the most often discussed attributes of digital badges, is the ability of badges to motivate learners. However, the research base to support this claim is in its infancy; there is little empirical evidence. A skills-based digital badge intervention was designed to demonstrate mastery learning in key, age-appropriate, STEM competencies aligned with Next Generation Science Standards (NGSS) and other educational standards. A mixed methods approach was used to study the impact of a digital badge intervention in the sample middle and high school population. Among the findings were statistically significant measures which substantiate that in this student population, the digital badges increased perceived competence and motivated learners to persist at task.

  13. Employer Perceptions of Critical Information Literacy Skills and Digital Badges

    Science.gov (United States)

    Raish, Victoria; Rimland, Emily

    2016-01-01

    Digital badges are an educational innovation used to measure learning of specific skills, such as information literacy. However, few studies have quantitatively surveyed employers for their perceptions about information literacy skills or digital badges. An online survey was developed and sent to employers to gauge perceptions of information…

  14. Badges to Acknowledge Open Practices: A Simple, Low-Cost, Effective Method for Increasing Transparency.

    Directory of Open Access Journals (Sweden)

    Mallory C Kidwell

    2016-05-01

    Full Text Available Beginning January 2014, Psychological Science gave authors the opportunity to signal open data and materials if they qualified for badges that accompanied published articles. Before badges, less than 3% of Psychological Science articles reported open data. After badges, 23% reported open data, with an accelerating trend; 39% reported open data in the first half of 2015, an increase of more than an order of magnitude from baseline. There was no change over time in the low rates of data sharing among comparison journals. Moreover, reporting openness does not guarantee openness. When badges were earned, reportedly available data were more likely to be actually available, correct, usable, and complete than when badges were not earned. Open materials also increased to a weaker degree, and there was more variability among comparison journals. Badges are simple, effective signals to promote open practices and improve preservation of data and materials by using independent repositories.

  15. A new TLD badge with machine readable ID for fully automated readout

    International Nuclear Information System (INIS)

    Kannan, S. Ratna P.; Kulkarni, M.S.

    2003-01-01

    The TLD badge currently being used for personnel monitoring of more than 40,000 radiation workers has a few drawbacks such as lack of on-badge machine readable ID code, delicate two-point clamping of dosimeters on an aluminium card with the chances of dosimeters falling off during handling or readout, projections on one side making automation of readout difficult etc. A new badge has been designed with a 8-digit identification code in the form of an array of holes and smooth exteriors to enable full automation of readout. The new badge also permits changing of dosimeters when necessary. The new design does not affect the readout time or the dosimetric characteristics. The salient features and the dosimetric characteristics are discussed. (author)

  16. The use of film badges for personnel monitoring

    International Nuclear Information System (INIS)

    Ehrlich, M.

    1962-01-01

    Photographic film is fairly inexpensive and durable and as a result of irradiation its radiosensitive components undergo relatively permanent changes. With proper calibration the optical density of the development and fixed photographic film can be related to radiation exposure. Personnel monitoring with photographic film is the method of choice in many laboratories, and this manual gives guidelines for the use of photographic film in personnel dosimetry.

  17. Analysis of reaction products of food contaminants and ingredients: bisphenol A diglycidyl ether (BADGE) in canned foods.

    Science.gov (United States)

    Coulier, Leon; Bradley, Emma L; Bas, Richard C; Verhoeckx, Kitty C M; Driffield, Malcolm; Harmer, Nick; Castle, Laurence

    2010-04-28

    Bisphenol A diglycidyl ether (BADGE) is an epoxide that is used as a starting substance in the manufacture of can coatings for food-contact applications. Following migration from the can coating into food, BADGE levels decay and new reaction products are formed by reaction with food ingredients. The significant decay of BADGE was demonstrated by liquid chromatographic (LC) analysis of foodstuffs, that is, tuna, apple puree, and beer, spiked with BADGE before processing and storage. Life-science inspired analytical approaches were successfully applied to study the reactions of BADGE with food ingredients, for example, amino acids and sugars. An improved mass balance of BADGE was achieved by selective detection of reaction products of BADGE with low molecular weight food components, using a successful combination of stable isotopes of BADGE and analysis by LC coupled to fluorescence detection (FLD) and high-resolution mass spectrometric (MS) detection. Furthermore, proteomics approaches showed that BADGE also reacts with peptides (from protein digests in model systems) and with proteins in foods. The predominant reaction center for amino acids, peptides, and proteins was cysteine.

  18. Superciliums in white-eared hummingbirds as badges of status signaling dominance.

    Science.gov (United States)

    González-García, Juan Manuel; Lara, Carlos; Quesada, Javier; Chávez-Zichinelli, Carlos A; Serrano-Meneses, Martín A

    2018-04-03

    The role of badges as indicators of contest ability has been previously described. In hummingbirds, the exhibition of a badge is expected to save energy expenditure in agonistic interactions and to favor energy intake. Here, we investigate whether variable supercilium size in the white-eared hummingbird has a role in dominance status signaling. Firstly, 45 hummingbird males were captured and their superciliums were photographed to investigate variation in size and any possible allometric relationships. Secondly, 42 male birds were used to analyze whether the supercilium has a role in dominance status signaling in a dyadic contest. We found that supercilium size varied continuously but that despite variability between individuals, there was no relationship between supercilium size and body size. However, our dyad experiment indicated that birds with larger badges were able to make more visits to the feeders than individuals with smaller badges. We suggest a status signaling function of the supercilium.

  19. Teachers' Perceptions of Digital Badges as Recognition of Professional Development

    Science.gov (United States)

    Jones, W. Monty; Hope, Samantha; Adams, Brianne

    2018-01-01

    This mixed methods study examined teachers' perceptions and uses of digital badges received as recognition of participation in a professional development program. Quantitative and qualitative survey data was collected from 99 K-12 teachers who were awarded digital badges in Spring 2016. In addition, qualitative data was collected through…

  20. The Effect of Achievement Badges on Students’ Behavior: An Empirical Study in a University-Level Computer Science Course

    Directory of Open Access Journals (Sweden)

    Lasse Hakulinen

    2015-02-01

    Full Text Available Achievement badges are a form of gamification that are used in an attempt to increase user engagement and motivation in various systems. A badge is typically a graphical icon that appears as a reward for the user after reaching an achievement but that has no practical value. In this study, we describe and evaluate the use of achievement badges in the ANONYMOUS online learning environment where students solve interactive, automatically assessed exercises in a Data Structures and Algorithms course throughout the semester. We conducted an experiment where the students (N=281 were randomly divided into a treatment and a control group, with and without achievement badges. Students in the treatment group were awarded achievement badges, for example, for solving exercises on the first attempt, doing exercises early, or solving all the exercises in a round with full points. Grading was the same for both groups, i.e. collecting badges did not affect the final grade, even though the exercise points themselves did. Students’ activity in ANONYMOUS was logged in order to find out whether the achievement badges had an effect on their behavior. We also collected numerical and open-ended feedback in order to find out students’ attitudes towards the badges. Our results show that achievement badges can be used to affect students’ behavior. Statistically significant differences were observed in the time used per exercise, number of sessions, total time, and normalized total number of badges. Furthermore, the majority of the students reported being motivated by the badges. Based on our findings, achievement badges seem to be a promising method to motivate students and to encourage desired study practices.

  1. Girl Scout Camps and Badges: Engaging Girls in NASA Science

    Science.gov (United States)

    Harman, P. K.; DeVore, E. K.

    2017-12-01

    Reaching for the Stars: NASA Science for Girl Scouts (Girl Scout Stars) disseminates NASA STEM education-related resources, fosters interaction between Girl Scouts and NASA Subject Matter Experts (SMEs), and engages Girl Scouts in NASA science and programs through space science badges and summer camps. A space science badge is in development for each of the six levels of Girl Scouts: Daisies, Grades K - 1; Brownies, Grades 2 -3; Juniors, Grades 4 -5; Cadettes, Grades 6 -8; Seniors, Grades 9 -10: and Ambassadors, Grades 11 -12. Daisy badge will be accomplished by following three steps with two choices each. Brownie to Ambassador badges will be awarded by completing five steps with three choices for each. The badges are interwoven with science activities, role models (SMEs), and steps that lead girls to explore NASA missions. External evaluators monitor three rounds of field-testing and deliver formative assessment reports. Badges will be released in Fall of 2018 and 2019. Girl Scout Stars supports two unique camp experiences. The University of Arizona holds an Astronomy Destination, a travel and immersion adventure for individual girls ages 13 and older, which offers dark skies and science exploration using telescopes, and interacting with SMEs. Girls lean about motion of celestial objects and become astronomers. Councils send teams of two girls, a council representative and an amateur astronomer to Astronomy Camp at Goddard Space Flight Center. The teams were immersed in science content and activities, and a star party; and began to plan their new Girl Scout Astronomy Clubs. The girls will lead the clubs, aided by the council and amateur astronomer. Camps are evaluated by the Girl Scouts Research Institute. In Girl Scouting, girls discover their skills, talents and what they care about; connect with other Girl Scouts and people in their community; and take action to change the world. This is called the Girl Scout Leadership Experience. With girl-led, hands on

  2. Feasibility study on using three element TLD badge based on CaSO4:Dy as environmental dosimeter

    International Nuclear Information System (INIS)

    Choudhary, Sreeletha; BharathiLashmi, G.V.; Yasotha, E.; Devanathan, P.S.; Annalakshmi, O.; Mathiyarasu, R.

    2018-01-01

    A three element thermoluminescence badge based on CaSO 4 :Dy is used for personnel monitoring in India. The three discs of the badge is heated in sequential manner by hot nitrogen gas and from the amount of light emitted while heating, the doses are estimated. This badge was redesigned as a two element system and is used for environmental monitoring. Though the two element badge has some advantages, the software used for processing of TLDs in the semiautomatic reader has to be modified and separate badges has to be maintained for environmental dose measurements. In this work a feasibility study has been carried out to use the three element personnel monitoring badge itself for environmental monitoring also. This study was also carried out to understand the abnormal pattern of the glow curves observed in some field cards

  3. Badges of modern slavery

    OpenAIRE

    Paz-Fuchs, Amir

    2016-01-01

    Notwithstanding the 19th century formal abolition of slavery as legal ownership of people, modern slavery and forced labour have not been consigned to the past. In fact, their existence is more widespread, and made more difficult to tackle due to the lack of formal, legal criteria. This article suggests that reference to the past, historical institutions reveals seven ‘badges of slavery’ that are helpful in identifying occurrences of modern slavery and forced labour. These are: humiliation, o...

  4. Recognising Informal Elearning with Digital Badging: Evidence for a Sustainable Business Model

    Science.gov (United States)

    Law, Patrina

    2015-01-01

    Digital badging as a trend in education is now recognised. It offers a way to reward and motivate, providing evidence of skills and achievements. Badged Open Courses (BOCs) were piloted by The Open University (OU) in 2013. The project built on research into the motivations and profiles of learners using free educational resources which the OU…

  5. Construction of pulse badge for upper extremities dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Cunha, Cledison de Jesus; Souza, Divanizia do Nascimento

    2005-01-01

    In the manipulation of radioactive materials in nuclear medicine service the body parts of the worker who more is displayed to the ionizing radiation is hands, forearm and arm. Therefore it is necessary to developing badges for easy reproduction monitoring and low cost to determine the doses level radiation received by the worker in these extremities. The aim of this work is to investigation of a new pulse badge, that is developed with thermoluminescent detectors of CaSO 4 :Dy (TLD) in a small plate of acrylic, perforated cardboard to deposit the TLD. This set was involved in plastic to protect of humidity and other harmful ambient factors, moreover, a bracelet was inserted, adaptable for any worker. This badge had been gotten resulted satisfactory, with a reply to the enough dose for a dosimetric evaluation. (author)

  6. Using badges to motivate and engage students

    DEFF Research Database (Denmark)

    Christensen, Inger-Marie F.; Hansen, Pernille Stenkil

    The gap between educational institutions and students is widening. Many institutions maintain traditional methods and adopt new at a slow pace. Some educators and developers are looking to gamification to bridge the gap. This workshop will help participants’ explore the potential of badges...

  7. Unusual ratio of TL readouts of different discs of personnel monitoring TLD badge based on CaSO4: Dy teflon disc

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Ande, C.D.; Kher, R.K.; Chourasiya, G.; Vashishtha, R.; Gupta, A.K.

    2005-01-01

    In India Personnel Monitoring against external radiation hazard of gamma, beta and X-rays is provided using a TLD badge based on CaSO 4 : Dy Teflon TLD disc. Unusual ratios of TL readouts of different discs of TLD badge (Disc Ratios) observed for service TLD badges of radiation workers were investigated and simulated. Simulations were carried out by exposure of TLD badges by speck type radioactive sources placed in contact of badges, exposure of TLD badges placed on concrete floor to a radiography source. Clues for the simulation were obtained from nature of work, radiological conditions during course of individuals' work whose TLD badges showed the unusual disc ratios and geometrical calculations performed. It is concluded that although the actual exposure condition during use is unknown, the unusual disk ratios observed for the service TLD badges can be simulated and utilized to arrive at probable exposure conditions. The study helped in investigations of the abnormal exposures and assigning doses to the concerned radiation workers. (author)

  8. Opportunities and Challenges with Digital Open Badges

    Science.gov (United States)

    Farmer, Tadd; West, Richard E.

    2016-01-01

    With increasing interest in competency and outcome-based education, and the blending of formal and informal learning, there is increasing need for credentials to match these learning paradigms. In this article, the authors discuss the benefits, challenges, and potential future directions for open digital badges--one potential alternative…

  9. Studies on α-Al2O3: C based optically stimulated luminescence badge for eye lens monitoring applications

    International Nuclear Information System (INIS)

    Kumar, Munish; Kulkarni, M.S.; Ratna, P.; Gaikwad, N.; Tripathi, S.M.; Sharma, S.D.; Babu, D.A.R.; Bhatnagar, Amit; Muthe, K.P.; Sharma, D.N.

    2014-01-01

    The prototype two element eye-lens dosimeter badge based on indigenously developed α-Al 2 O 3 : C optically stimulated luminescence dosimeter was investigated comprehensively for its suitability for eye-lens monitoring applications. The badge is calibrated to measure the eye-lens dose in terms of H p (3). The minimum measurable dose using the eye-lens dosimeter badge is observed to be ∼ 35 μSv. This prototype eye-lens dosimeter badge was found to be suitable for measuring doses from X-rays, beta and gamma radiations to the eye-lens. The satisfactory performance of the prototype two element eye-lens dosimeter badge along with its attractive features such as multiple readout, less processing time, very good beta response uniquely position it for monitoring the eye-lens dose are presented. (author)

  10. Buy badges and help finance Cap Loisirs activities!

    CERN Multimedia

    2008-01-01

    Please give a warm welcome to Cap Loisirs’ volunteers who will be manning a stand at the main entrance on Friday 8 February! In honour of St. Valentine’s Day, they will be selling a selection of 5 badges designed by artist Anna Sommer, depicting declarations of love by our friends from the animal kingdom. Price : Frs. 3.- per badge The aim of Fondation Cap Loisirs is to provide leisure activities for mentally handicapped children, adolescents and adults. The Foundation offers a wide range of activities which allow the mentally handicapped to enjoy quality leisure in areas as varied as culture, sport, tourism, travel and artistic expression. Fondation Cap Loisirs Rue de Monthoux 66 – 1201 Geneva – Tel: 022 731 86 00 – CCP Genève 12-5587-5 – caploisirs@caploisirs.ch – http://www.Caploisirs.ch

  11. Tutoring Online Tutors: Using Digital Badges to Encourage the Development of Online Tutoring Skills

    Science.gov (United States)

    Hrastinski, Stefan; Cleveland-Innes, Martha; Stenbom, Stefan

    2018-01-01

    Online tutors play a critical role in e-learning and need to have an appropriate set of skills in addition to subject matter expertise. This paper explores how digital badges can be used to encourage the development of online tutoring skills. Based on previous research, we defined three digital badges, which are examples of essential tutoring…

  12. Design Principles for Digital Badges Used in Libraries

    Science.gov (United States)

    Rimland, Emily; Raish, Victoria

    2017-01-01

    Digital badges give libraries greater flexibility in delivering impactful instruction to students. They serve as flexible, stackable microcredentials that sequence an information literacy experience across the curriculum. Design considerations rooted in learning theory have a foundation through which to drive decisions. Information literacy badges…

  13. Magnetic characterisation of longitudinal thin film media

    International Nuclear Information System (INIS)

    Dova, P.

    1998-09-01

    Magnetic characterisation techniques, as applied to longitudinal thin film media, have been investigated. These included the study of the differentials of the remanence curves, the delta-M plot and the examination of the critical volumes. Several thin film structures, which are currently used or are being considered for future media applications, have been examined using these techniques. Most of the films were Co-alloys with the exception of a set of Barium ferrite films. Both monolayer and multilayer structures were studied. It was found that the study of activation volumes provides a better insight into the reversal mechanisms of magnetic media, especially in the case of complex structures such as multilayer films and films with bicrystal microstructure. Furthermore, an evaluation study of different methods of determining critical volumes showed that the method using time dependence measurements and the micromagnetic approach is the most appropriate. The magnetic characteristics of the thin film media under investigation were correlated with their microstructure and, where possible, with their noise performance. Magnetic force microscopy was also used for acquiring quasi-domain images in the ac-demagnetised state. It was found that in all Co-alloy films the dominant intergranular coupling is magnetising in nature, the level of which is governed by the Cr content in the magnetic layer. In the case of laminated media it was found that when non-magnetic spacers are used, the nature of the interlayer coupling depends on the spacer thickness. In double layer structures with no spacer, the top layer replicates the crystallographic texture of the bottom layer, and the overall film properties are a combination of the two layers. In bicrystal films the coupling is determined by the Cr segregation in the grain boundaries. Furthermore, the presence of stacking faults in bicrystal films deteriorates their thermal stability, but can be prevented by improving the epitaxial

  14. Propagation of bulk longitudinal waves in thin films using laser ultrasonics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Young [Dept. of Mechanical Engineering, Dong-eui University, Busan (Korea, Republic of)

    2016-08-15

    This paper presents the investigation of the propagation behavior of bulk longitudinal waves generated by an ultrafast laser system in thin films. A train of femtosecond laser pulses was focused onto the surface of a 150-nm thick metallic (chromium or aluminum) film on a silicon substrate to excite elastic waves, and the change in thermoreflectance at the spot was monitored to detect the arrival of echoes from the film/substrate interface. The experimental results show that the film material characteristics such as the wave velocity and Young's modulus can be evaluated through curve-fitting in numerical solutions. The material properties of nanoscale thin films are difficult to measure using conventional techniques. Therefore, this research provides an effective method for the nondestructive characterization of nanomaterials.

  15. Periodicity of TLD badge personnel monitoring service in India

    International Nuclear Information System (INIS)

    Kher, R.K.; Joshi, V.D.; Kaushik, Aruna; Sharma, Amiy; Chatterjee, S.

    2003-01-01

    The periodicity of an individual monitoring service is an important aspect. Presently minimum period for TLD badge service is maintained as 'calendar month' and choice of quarterly service is also offered. The periodicity of the TLD service for a given category/application type of institution, is to be fixed taking into account level of average occupational doses in all or typical institutions of given category and other information indicating the status of safety and possible fluctuations of exposure levels and potential for overexposure cases. This paper presents the status on the periodicity of TLD Badge Service as is evolved and adopted for the four broad categories i.e. DAE (Nuclear Fuel Cycle) Institutions, Industrial, Medical, Research institutions. It is concluded that quarterly service is a convenient option for institution categories where type of work/workload, and work practices are such that occupational exposures could be normally kept below about one mSv or so in the monitoring period, average annual dose less than 1 mSv and persons receiving annual dose >10 mSv is less than 1% of total in the category. Also, the judicious use of the flexibility in the periodicity of TLD Badge service would help (i) to keep the monitoring related workload to the optimum for the monitoring units and (ii) to keep the expenses incurred by the institution towards monitoring to the minimum without sacrificing radiation safety (iii) to focus the extra monitoring efforts on the applications/situations requiring improvement in radiation safety. (author)

  16. Gamification of Nursing Education With Digital Badges.

    Science.gov (United States)

    White, Meagan; Shellenbarger, Teresa

    Digital badges (DBs) serve as an innovative approach to gamifying nursing education by engaging socially connected, technologically savvy nursing students in learning. Because assessment and credentialing mechanisms are housed and managed online, DBs are designed as visible indicators of accomplishment and skill. This article describes important considerations for faculty when incorporating game-based pedagogies such as DB into nursing education and identifies potential pitfalls with DB use that faculty should consider.

  17. N2 gas station and gas distribution system for TLD personnel monitoring gas based semi-automatic badge readers

    International Nuclear Information System (INIS)

    Chourasiya, G.; Pradhan, S.M.; Kher, R.K.; Bhatt, B.C

    2003-01-01

    Full text: New improvised hot gas based Auto TLD badge reader has several advantages over the earlier contact heating based manual badge reader. It requires constant supply of N 2 gas for its operation; The gas supplied using replaceable individual gas cylinders may have some safety hazards in their handling. It was therefore considered worthwhile to setup a N 2 gas assembly/ station outside the lab area and to bring regulated gas supply through network of tubes with proper regulation to the individual readers. The paper presents detailed description of the gas station and distribution system. The system is quite useful and offers several practical advantages for readout of TLD badges on the semiautomatic badge readers based on gas heating. Important advantage from dosimetric point of view is avoidance of gas flow rate fluctuations and corresponding variations in TL readouts

  18. Analysis of reaction products of food contaminants and ingredients: Bisphenol A diglycidyl ether (BADGE) in canned foods

    NARCIS (Netherlands)

    Coulier, L.; Bradley, E.L.; Bas, R.C.; Verhoeckx, K.C.M.; Driffield, M.; Harmer, N.; Castle, L.

    2010-01-01

    Bisphenol A diglycidyl ether (BADGE) is an epoxide that is used as a starting substance in the manufacture of can coatings for food-contact applications. Following migration from the can coating into food, BADGE levels decay and new reaction products are formed by reaction with food ingredients. The

  19. A microcontroller based readout unit for a smart personnel monitoring TLD badge

    International Nuclear Information System (INIS)

    Gaonkar, U.P.; Kulkarni, M.S.; Kannan, S.

    1997-01-01

    An automated TLD personnel monitoring system is under development to cope up with the requirements of personnel monitoring of rapidly growing number of radiation workers. The core of the system is a smart TLD badge incorporating a memory device and a microcontroller based readout unit for reading the memory contents of the badge. The memory is used to store personnel data including the accumulated dose data. The reader unit has a serial RS 232C interface for connection to a PC for entering/modifying data in the memory. A password protected software has also been developed in C for entering/modifying the data in the single memory. 3 figs

  20. Transverse and longitudinal electrooptic properties of highly (100) oriented Pb(Zr,Ti)O{sub 3} films grown on glass substrates

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jong-Jin [Department of Future Technology, Korea Institute of Machinery and Materials, 66 Sang-Nam Dong, Chang-Won, Gyeong-Nam, 641-010 (Korea, Republic of) and School of Materials Science and Engineering, Seoul National University, Seoul, 151-742 (Korea, Republic of)]. E-mail: finaljin@kmail.kimm.re.kr; Park, Gun-Tae [School of Materials Science and Engineering, Seoul National University, Seoul, 151-742 (Korea, Republic of); Kim, Hyoun-Ee [School of Materials Science and Engineering, Seoul National University, Seoul, 151-742 (Korea, Republic of); Kim, Dal-Young [Department of Visual Optics, Seoul National University of Technology, 172 Gongreung 2-dong, Nowon-gu, Seoul 139-743 (Korea, Republic of)

    2006-12-05

    The Pb(Zr,Ti)O{sub 3} [PZT] films with a preferred orientation generally have columnar texture. Because the properties of a PZT film are strongly dependent on its crystallographic direction, the electrooptic properties along the longitudinal and transverse direction are expected to be anisotropic. In this study, highly (100) oriented PZT films were grown on glass and ITO (Indium Tin Oxide) coated glass substrates using the sol-gel multi-coating method with lanthanum nitrate and lanthanum nickel nitrate as buffer layers. The longitudinal and transverse electrooptic properties of the textured films were characterized by transmission-mode measuring equipment with a Senarmont compensator using a sample tilting method. The calculated longitudinal and transverse electrooptic coefficients of the highly (100) oriented PZT films were 147 and 250 pm/V, respectively.

  1. Matrix effect on leaching of Bisphenol A diglycidyl ether (BADGE) from epoxy resin based inner lacquer of aluminium tubes into semi-solid dosage forms.

    Science.gov (United States)

    Lipke, Uwe; Haverkamp, Jan Boris; Zapf, Thomas; Lipperheide, Cornelia

    2016-04-01

    To study the impact of different semi-solid dosage form components on the leaching of Bisphenol A (BPA) and Bisphenol A diglycidyl ether (BADGE) from the epoxy resin-based inner lacquer of aluminium tubes, the tubes were filled with different matrix preparations and stored at an elevated temperature. Despite compliance with the European Standards EN 15348 and EN 15766 on porosity and polymerisation of internal coatings of aluminium tubes, the commercially available tubes used in the study contained an increased amount of polymerisation residues, such as unbound BPA, BADGE and BADGE derivatives in the lacquer, as determined by acetonitrile extraction. Storage of Macrogol ointments in these tubes resulted in an almost quantitative migration of the unbound polymerisation residues from the coating into the ointment. In addition, due to alterations observed in the RP-HPLC chromatograms of the matrix spiked with BADGE and BADGE derivatives it is supposed that the leachates can react with formulation components. The contamination of the medicinal product by BPA, BADGE and BADGE derivatives can be precluded by using aluminium tubes with an internal lacquer with a low degree of unbound polymerisation residues. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Open digital badges in Open edX

    OpenAIRE

    Hickey, Daniel T.; Barba, Lorena A.; Lemoie, Kerri; Amigot, Michael; Ewens, Damian

    2014-01-01

    Slides for the presentation at the Open edX Conference, Cambridge, MA 2014.   This talk presented the first public update of our collaboration to implement open digital badges in Dr. Barba's new MOOC, "Practical Numerical Methods with Python." It's a collaboration between Indiana University's Center for Research on Learning and Technology (led by Prof. Daniel T. Hickey);  Prof. Lorena Barba and her team at George Washington University, with her partners at IBL Studios Education, and...

  3. Response of TLD badge for the estimation of exposure conditions in diagnostic x-ray departments - use of lead aprons

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.; Bakshi, A.K.

    2002-01-01

    The present study was undertaken to ascertain the conditions of exposure of the TLD badge and to evaluate the inaccuracy involved in the estimation of dose received by the worker using an averaged lead apron transmission factor for the use of the badge above lead apron

  4. SSDL Preparation for Implementation of the Use of OSL Dosimeters in Malaysia

    International Nuclear Information System (INIS)

    Sangau, J.K.; Taiman Kadni; Ahmad Bazlie Abdul Kadir

    2013-01-01

    Since the early 1980's, film badge has been widely used as a device of personal dose monitoring in Malaysia. Secondary Standard Dosimetry Laboratory (SSDL), as a service center for film badge has obtained the supply of personal monitoring film from Agfa Gevaert, Belgium every year. As the uses of film badge have some weaknesses, it has prompted SSDL to find an alternative dosimeter to replace the film badge. Based on the studies that have been conducted, SSDL has selected OSL dosimeter (Optically Stimulated Luminescent Dosimeter) to replace the film badge and is expected to be fully operational by middle of 2015. This paper aims to explain the selection of OSL dosimeter and planning carried out to ensure the success of their application in Malaysia. (author)

  5. Feasibility Study on Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation

    International Nuclear Information System (INIS)

    Jung, Inha

    2013-12-01

    This report on the 'Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation' is belonged to the final report on the preliminary study of the first subject in 2013 for civilian project. This was complimented on the responsible of the Korea Atomic Energy Research Institute for 1 st of June 2013 to 30 th of November 2013. We are going to make sterilization the badge using the gamma ray and supplying the oxygen by nano-bubble oxygen rich water for cultivating the Matsutake Mushroom, instead of the conventional process of sterilization of the badge by hot steam over 120 .deg. C consuming over 8 hours and expensive ventilation system for supplying the fresh air for delivering the oxygen

  6. Feasibility Study on Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Inha

    2013-12-15

    This report on the 'Sterilization of Badge using Radiation and Cultivation by Nano-bubble Water for Matsutake Mushroom Cultivation' is belonged to the final report on the preliminary study of the first subject in 2013 for civilian project. This was complimented on the responsible of the Korea Atomic Energy Research Institute for 1{sup st} of June 2013 to 30{sup th} of November 2013. We are going to make sterilization the badge using the gamma ray and supplying the oxygen by nano-bubble oxygen rich water for cultivating the Matsutake Mushroom, instead of the conventional process of sterilization of the badge by hot steam over 120 .deg. C consuming over 8 hours and expensive ventilation system for supplying the fresh air for delivering the oxygen.

  7. Digital Badges for Staff Training: Motivate Employees to Learn with Micro-Credentials

    Science.gov (United States)

    Copenhaver, Kimberly; Pritchard, Liz

    2017-01-01

    Integrating micro-credentialing into employee training programs offers libraries an innovative and individualized way to recognize and certify learning and achievement. Digital badges provide a low-cost initiative to support learning benefiting both the individual and institution, offering evidence of skill development that transcends the library…

  8. Recognising Informal Elearning with Digital Badging: Evidence for a Sustainable Business Model

    Directory of Open Access Journals (Sweden)

    Patrina Law

    2015-11-01

    Full Text Available Digital badging as a trend in education is now recognised. It offers a way to reward and motivate, providing evidence of skills and achievements. Badged Open Courses (BOCs were piloted by The Open University (OU in 2013. The project built on research into the motivations and profiles of learners using free educational resources which the OU makes available through its OpenLearn platform (Law, Perryman & Law, 2013. This research found that an increasing proportion of learners are keen to have their informal learning achievements recognised (Law & Law, 2014. Based on these data, a suite of free BOCs, assessed through the deployment of Moodle quizzes, was launched. This paper reports on evaluation of the BOCs and what we now know of the strategic importance of informal learning recognition. The initiative aligns with University strategies to provide accessible routes into formal learning for those who might not otherwise have the opportunity.

  9. Design of photon energy compensation filters for the new four element CaSO4:Dy TLD badge

    International Nuclear Information System (INIS)

    Mishra, D.R.; Kulkarni, M.S.; Pradeep, Ratna; Kannan, S.

    2001-01-01

    A new four element TLD badge using CaSO 4 :Dy is being developed for the estimation of personal dose equivalents Hp(10) and Hp(0.07) and to discriminate them in the mix field (low energy x-ray and high energy γ-ray). Design of energy compensation filters for the new TLD badge is discussed. The total metal filter thickness is kept less than 1 mm. The first and second elements of the badge are planned to be open and plastic (≅180 gm/cm 2 ) window. For the third element a combination of 0.2 mm Sn + 0.7mm Cu + 0.1 mm Al with mass thickness ≅ 1100 mg/cm 2 is proposed which gives energy dependent response similar to Hp(10) within ± 20% (above 80 keV). For the fourth dosimeter a filter combination of 0.4 mm Al + 0.07 mm Sn is proposed which gives Hp(10)xR response for diagnostic x-rays within ± 10% in the mix field. (author)

  10. Use of lead aprons - further considerations of estimation of doses and conditions of acute exposures of TLD badge in diagnostic x-ray institutions

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.

    2003-01-01

    In the recent study the authors reported that the exposure conditions of the use of the TLD badge, whether worn under or over the lead apron could be estimated from the readout of the TLD badge used in X-ray diagnostic departments. The effectiveness of lead aprons procured from different suppliers having the same value of quoted nominal lead equivalence was found to vary severely and this indicated some limitation in the applicability of the method of evaluation of exposure conditions of the badge. The transmission factors for the lead aprons varied up to a factor of 15 for the same value of quoted nominal lead equivalence procured from three different suppliers. This is of serious consequences in radiation protection and attracts attention for quality control. An error in the estimation of the exposure conditions of the TLD badge could lead to an underestimation of doses up to 4 times using the prevalent method. The estimation of the actual doses of radiation workers in the cases of over-exposures for the situations of the use of the TLD badge over the lead apron showed that the variation in the quality of lead aprons could be wrong in the range from 1.6 to 25 times even if the kVp of the machine is exactly known. Therefore, attempt should not be made to estimate the actual doses under lead apron from the readout of the TLD badge worn over the apron, as the real values of the transmission factors of the aprons and kVp of the X-ray machine may not be available. (author)

  11. Nobels Nobels laureates photographed by Peter Badge

    CERN Document Server

    2008-01-01

    A unique photographic record of all living Nobel laureates. In this handsome coffee-table book, photographer Peter Badge captures the likeness of every living Nobel laureate in a lasting black-and-white image -- more than 300 striking portraits in all. Brief biographical sketches accompanying the large-scale photographs pay homage to each laureate's singular contribution to science, literature or world peace. Bringing readers face-to-face with Nelson Mandela, Jimmy Carter, the Dalai Lama, James Watson, Gabriel García Márquez, Toni Morrison, Rita Levi-Montalcini, Linda Buck, and Paul Samuelson among many others, NOBELS offers an intimate and compelling look at well-known honorees as well as lesser-known recipients. A fascinating word/image tableau.

  12. Learning Analytics and Digital Badges: Potential Impact on Student Retention in Higher Education

    Science.gov (United States)

    Mah, Dana-Kristin

    2016-01-01

    Learning analytics and digital badges are emerging research fields in educational science. They both show promise for enhancing student retention in higher education, where withdrawals prior to degree completion remain at about 30% in Organisation for Economic Cooperation and Development member countries. This integrative review provides an…

  13. Perceptions and Uses of Digital Badges for Professional Learning Development in Higher Education

    Science.gov (United States)

    Dyjur, Patti; Lindstrom, Gabrielle

    2017-01-01

    Few instructors in higher education have completed a formal teaching program and, therefore, rely on informal professional development opportunities to enhance their teaching practice. Micro-credentialing in the form of digital badges is one way in which instructors can document their non-credit learning and accomplishments. This mixed methods…

  14. A scoping review towards the conceptualization of a digital Open Badges ecosystem in South Africa

    CSIR Research Space (South Africa)

    Motheeram, Preia

    2016-11-01

    Full Text Available relevant and rewarding pathways for learners. Open Badges can provide the infrastructure to facilitate this recognition of skills and achievements. In the absence of specific skills accreditation for informal skills and small scale competency development...

  15. Analytical theory and method for longitudinal magneto-optical Kerr effect of optically anisotropic magnetic film

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiao, E-mail: sps_wangx@ujn.edu.cn [School of Physics and Technology, University of Jinan, Jinan 250022 (China); School of Material Science and Engineering, University of Jinan, Jinan 250022 (China); Lian, Jie [School of Information Science and Engineering, Shandong University, Jinan 250100 (China); Li, Ping; Xu, XiJin [School of Physics and Technology, University of Jinan, Jinan 250022 (China); Li, MengMeng [School of Information Science and Engineering, Shandong University, Jinan 250100 (China)

    2017-01-15

    The Fresnel equations are solved to analyze the reflection and propagation properties of the ordinary and extraordinary light of the optically anisotropic magnetic film. Using the boundary and propagation matrix, the longitudinal magneto-optical Kerr rotation expression is derived. After that, simulations are performed on optically anisotropic and isotropic Co/SiO{sub 2} film. Results show that for Co material in the thin-film limit, the anisotropic Co can provide larger max rotations than the isotropic Co in the visible region. This is because that the refractive index discrepancy of optically anisotropic Co film reduces the Fresnel reflective coefficient r{sub pp,} which improves the Kerr rotation. This makes the optically anisotropic Co film more effective in magneto optical sensor design and device fabrication. - Highlights: • In this work, using the boundary matrix and media propagation matrix developed by Zak and S.D.Bader,we get the analytical solution of the magneto-optical Kerr rotation of the optical anisotropic magnetic film. • Results show that for film in the thin-film limit, the anisotropic Co can provide larger maximum rotations than the isotropic Co. • The improvement of Kerr rotation can be attributed to the refractive index discrepancy of optically anisotropic Co film which reduce the Fresnel reflective coefficient rpp.

  16. Radiation monitoring at Pakistan research reactor

    International Nuclear Information System (INIS)

    Ali, A.

    1984-05-01

    Area radiation monitoring is accomplished by using Tracer Lab. radiation monitor. Personnel monitoring is carried out using film badges, TLDs (Thermoluminescent Dosimeters) and pocket dosimeters. For the evaluation of monthly accumulated doses of radiation workers film badges/TLDs and for instantaneous/short term dose measurement in higher radiation zones pocket dosimeters are used in addition to film badge/TLD. Environmental monitoring is necessary to check the PARR operation effect on background radiation level in the vicinity of PINSTECH. (A.B.). 4 refs

  17. Chlorohydrins of bisphenol A diglycidyl ether (BADGE) and of bisphenol F diglycidyl ether (BFDGE) in canned foods and ready-to-drink coffees from the Japanese market.

    Science.gov (United States)

    Uematsu, Y; Hirata, K; Suzuki, K; Iida, K; Saito, K

    2001-02-01

    BADGE.2HCl and BFDGE.2HCl were determined in 28 samples of ready-to-drink canned coffee and 18 samples of canned vegetables (10 corn, 5 tomatoes and 3 others), all from the Japanese market. HPLC was used as the principal analytical method and GC-MS for confirmation of relevant LC fractions. BADGE.2HCl was found to be present in one canned coffee and five samples of corn, BFDGE.2HCl in four samples of canned tomatoes and in one canned corn. No sample was found which exceeded the 1 mg/kg limit of the EU for the BADGE chlorohydrins. However the highest concentration was found for the sum of BFDGE.2HCl anti BFDGE.HCl.H2O at a level of 1.5 mg/kg. A Beilstein test confirmed that all cans containing foods contaminated with BADGE.2HCl or BFDGE.2HCl had at lest one part coated with a PVC organosol.

  18. Environmental Science and Engineering Merit Badges: An Exploratory Case Study of a Non-Formal Science Education Program and the U.S. Scientific and Engineering Practices

    Science.gov (United States)

    Vick, Matthew E.; Garvey, Michael P.

    2016-01-01

    The Boy Scouts of America's Environmental Science and Engineering merit badges are two of their over 120 merit badges offered as a part of a non-formal educational program to U.S. boys. The Scientific and Engineering Practices of the U.S. Next Generation Science Standards provide a vision of science education that includes integrating eight…

  19. The relationship of over density to overexposure each film/screen systems in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Min; Huo Joon [Korea University, Seoul (Korea, Republic of); Taro, Hayash; Yuji, Ishida; Tatsuya, Sakurai [The Chemotherapeutic Istitute Hospital, Tokyo (Japan)

    1999-06-01

    This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition,we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from 2 {approx} 3 intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skin dose from chest x-ray film density. The error range was found in the range -13 percent {approx} +17 percent for between deductive entrance skin dose and the 2 {approx} 3 inter coastal chest x-ray film density to actual detective radiation dose with dosimeter. (author)

  20. Carrying an anti-nuclear-power badge in the teaching profession. BVerwG, decision of January 25, 1990. Tragen einer Anti-Atomkraft-Plakette im Schuldienst. Urteil des BVerwG vom 25. 1. 1990

    Energy Technology Data Exchange (ETDEWEB)

    Anon,

    1990-06-15

    The carrying of an anti-nuclear-power badge by a teacher during school hours violates the order to practice reticence in political activities. At the beginning of 1977 some teachers, the plaintiff as well, carried anti-nuclear-power badges, i.e. a round badge with a stylized red sun on a yellow background with the inscription 'Nuclear power - No, thank you'. Following a general direction by the educational authorities, the headmistress forbade plaintiff on 4.11.77 to visibly carry this badge during lessons. This protest having been without success, action was brought with partial success at the Administrative and Higher Administrative Court. The Federal Administrative Court dismissed the case. (orig./HSCH).

  1. Routine monitoring of eye dose; and reply

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, K; Jeans, S P; Faulkner, K; Bardsley, R A; Love, H G

    1985-12-01

    This letter briefly reports the assessment at Papworth Hospital of the feasibility of monitoring eye doses of staff using a film badge worn on the shoulder in addition to the badge worn under the lead apron. For three consecutive months hand and eye (forehead) dose were monitored using TLDs, while shoulder and body dose, recorded under the lead apron, were measured with film badges. For the four doctors monitored, (two radiologists and two cardiologists) the shoulder badge somewhat overestimated the eye dose. In the case of nurses, the dose recorded by the shoulder badge was of a similar order to the TLD-recorded eye dose. The reply from the Christie Hospital at Manchester comments on the use of the shoulder badge and contends that the use of forehead dosemeters to measure eye dose is to be preferred whenever possible.

  2. The interpretability of doctor identification badges in UK hospitals: a survey of nurses and patients.

    Science.gov (United States)

    Hickerton, Bethan C; Fitzgerald, Daniel John; Perry, Elizabeth; De Bolla, Alan R

    2014-07-01

    Hospital badges have multiple important purposes, but their essential role remains the clear identification of the bearer, including their professional status. The modernisation of medical careers in the National Health Service has changed terminology dramatically, resulting in a plethora of new job titles emerging among both doctors and nurses. To determine whether the new or old terminology allowed clearer identification of medical doctors by patients and nurses. We replicated 11 identification badges used in the Royal Cornwall Hospital and Wrexham Maelor Hospital, both current and before the introduction of new medical training terminology. Data were collected from 114 patients and 67 nurses, by asking them to (1) identify which name badges represented doctors and (2) rank them in order of seniority. Only 11% of patients and 60% of nurses identified a 'Foundation Year 1 Trainee' as a qualified medical doctor. Indeed, only 'General Practice Vocational Trainee' and 'Consultant' were both readily identifiable as qualified doctors to both patients and nurses. Ranking was also a problem, with only 19% of patients and 45% of nurses able to correctly grade medical doctors using the current terminology. The old terminology allowed more accurate identification by nurses, with over 80% successfully ranking and marking the title appropriately. Current terminology is a source of confusion to both patients and members of the immediate medical care team, with nurses unable to correctly identify medical doctors. Our study indicates that a review of terminology is necessary to ensure patients, and staff, are able to communicate effectively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Evaluation algorithm for Hp (10), Hp (0.07) and response matrix in mixed fields of 137Cs+90Sr/90Y for badge TLD without use of its commercial holder

    International Nuclear Information System (INIS)

    Alvarez R, Jose T.; Tovar M, Victor M.; Castaneda P, Mario; Padilla, Ismael

    2008-01-01

    American standards HPS N 13.11 (1993, 2001) set up performance category tests for deep and shallow personal equivalent dose evaluated by dosimetry processors. These standards establish the parameters bias B, standard deviation S and tolerance level L, whose values indicate the deviations from the conventionally true value for the equivalent dose. On the other hand, for a right evaluation of the equivalent dose, all personal dosimetry systems have four basic components: badge, holder, reading protocol and dose evaluation algorithm. However, in Nuclear Plant Laguna Verde NPP dosimetry laboratory uses the badges Panasonic 802 A without Panasonic UD874AT holder, and instead employs a polyethylene holder bag to protect the badge from misuse. This situation disables the manufacturer algorithm designed for the combination: badge + holder. Therefore, the purpose of this work is to design a personal equivalent dose algorithm for this badge + bag, such this corrected algorithm let fulfill the HPS N 13.11 (1993) categories II, IV, V and VII. The algorithm starts from the readings of the elements: E1, E2, E3 and E4, only corrected by their element correction factor ECF. Additionally, we characterize the badge + bag by means of the response function for: 137 Cs, 85 Kr and 90 Sr/ 90 Y radiation fields. Finally, for validation of the algorithm one verifies that parameters B, S and L accomplish with the limits indicated by the standard. (author)

  4. Optimization of the energy response of radiographic films by Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Moslehi, A. [Physics Department, Faculty of Science, Arak University, Shariati Square, Arak 38156 (Iran, Islamic Republic of); Hamidi, S., E-mail: s-hamidi@araku.ac.i [Physics Department, Faculty of Science, Arak University, Shariati Square, Arak 38156 (Iran, Islamic Republic of); Raisali, G. [Radiation Application Research School, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran (Iran, Islamic Republic of); Gheshlaghi, F. [Film Badge Dosimetry Laboratory, National Radiation Protection Department, Iranian Nuclear Regulatory Authority, Atomic Energy Organization of Iran (Iran, Islamic Republic of)

    2010-01-15

    In the present work a simple model for calculation of the energy response of radiographic films was introduced. According to the model the energy response of a radiographic film is directly proportional to the optical density on the film and thus to the number of developed grains in the emulsion. The model was simulated by Monte Carlo method using MCNP code and the relative energy response of Kodak type 2 film under a few filters of A.E.R.E./R.P.S. film badge was calculated. The simulated responses were in agreement with the experimental data in the region of 30 keV-1.5 MeV. In the next stage a multi-element filter was simulated to optimize the energy response in the above energies. The energy response varied by 25% between 40 keV and 1.5 MeV. So the dose received by the film is equivalent to the desired true dose and there would be no need to the correction factors.

  5. Optimization of the energy response of radiographic films by Monte Carlo method

    International Nuclear Information System (INIS)

    Moslehi, A.; Hamidi, S.; Raisali, G.; Gheshlaghi, F.

    2010-01-01

    In the present work a simple model for calculation of the energy response of radiographic films was introduced. According to the model the energy response of a radiographic film is directly proportional to the optical density on the film and thus to the number of developed grains in the emulsion. The model was simulated by Monte Carlo method using MCNP code and the relative energy response of Kodak type 2 film under a few filters of A.E.R.E./R.P.S. film badge was calculated. The simulated responses were in agreement with the experimental data in the region of 30 keV-1.5 MeV. In the next stage a multi-element filter was simulated to optimize the energy response in the above energies. The energy response varied by 25% between 40 keV and 1.5 MeV. So the dose received by the film is equivalent to the desired true dose and there would be no need to the correction factors.

  6. Performance evaluation of vertical feed fully automated TLD badge reader using 0.8 and 0.4 mm teflon embedded CaSO4:Dy dosimeters

    International Nuclear Information System (INIS)

    Ratna, P.; More, Vinay; Kulkarni, M.S.

    2012-01-01

    The personnel monitoring of more than 80,000 radiation workers in India is at present carried out by semi-automated TLD badge Reader systems (TLDBR-7B) developed by Radiation Safety Systems Division, Bhabha Atomic Research Centre. More than 60 such reader systems are in use in all the personnel monitoring centers in the country. Radiation Safety Systems Division also developed the fully automated TLD badge reader based on a new TLD badge having built-in machine readable ID code (in the form of 16x3 hole pattern). This automated reader is designed with minimum of changes in the electronics and mechanical hardware in the semiautomatic version (TLDBR-7B) so that such semi-automatic readers can be easily upgraded to the fully automated versions by using the new TLD badge with ID code. The reader was capable of reading 50 TLD cards in 90 minutes. Based on the feedback from the users, a new model of frilly automated TLD badge Reader (model VEFFA-10) is designed which is an improved version of the previously reported fully Automated TLD badge reader. This VEFFA-10 PC based Reader incorporates vertical loading of TLD bards having machine readable ID code. In this new reader, a vertical rack, which can hold 100 such cards, is mounted from the right side of the reader system. The TLD card falls into the channel by gravity from where it is taken to the reading position by rack and pinion method. After the readout, the TLD card is dropped in a eject tray. The reader employs hot N 2 gas heating method and the gas flow is controlled by a specially designed digital gas flow meter on the front panel of the reader system. The system design is very compact and simple and card stuck up problem is totally eliminated in the reader system. The reader has a number of self-diagnostic features to ensure a high degree of reliability. This paper reports the performance evaluation of the Reader using 0.4 mm thick Teflon embedded CaSO 4 :Dy TLD cards instead of 0.8 mm cards

  7. Remeasurement of early Harwell personnel film dosimeters

    International Nuclear Information System (INIS)

    Smith, J.W.; McGuinness, E.A.

    1981-05-01

    The A.E.A. epidemiological study depends for its radiation dose data on records of film badge doses which have been stored continuously since 1947. The records were originally kept to assist in the control of radiation hazard to the individual and for that purpose doses below the measurement threshold were unimportant. The epidemiological study could consider these doses to be either zero or equal to the measurement threshold, but both assumptions risk introducing a bias. Samples of old films worn in 1955 and 1960 were therefore remeasured using the present-day lower threshold of 0.005 rems to aid the choice of the most correct estimate. It was found that there had been little change in the blackening on the films or in the assessed radiation dose for 238 films above the original threshold of 0.05 rems, confirming that remeasurement was possible. The 2426 films previously recorded as ''<0.05 rems'' were found on remeasurement to give an average dose of 0.009 rems. A similar epidemiological study of radiation workers at Hanford took threshold doses as equal to zero and considered only positive measured doses. The errors possible with this approach are discussed. (author)

  8. Intense coherent longitudinal optical phonons in CuI thin films under exciton-excitation conditions

    International Nuclear Information System (INIS)

    Kojima, O.; Mizoguchi, K.; Nakayama, M..

    2005-01-01

    We have investigated the dynamical properties of the coherent longitudinal optical (LO) phonon in CuI thin films grown on a NaCl substrate by vacuum deposition. The intense coherent LO phonon in the CuI thin film is observed under the exciton-excitation conditions. Moreover, the pump-energy dependence of the amplitude of the coherent LO phonon shows peaks at the heavy-hole and light-hole exciton energies. The enhancement of the coherent LO phonon under the exciton-resonance condition is much larger than that in an ordinary semiconductor quantum well system such as a GaAs/AlAs one. These facts demonstrate that the intense coherent LO phonon is generated under the exciton-excitation condition in a material with a strong exciton-phonon interaction such as CuI

  9. The Effect of Badges on the Engagement of Students with Special Educational Needs: A Case Study

    Science.gov (United States)

    Sitra, Ourania; Katsigiannakis, Vangelis; Karagiannidis, Charalampos; Mavropoulou, Sofia

    2017-01-01

    This paper addresses the perceived benefits from gamification in the context of special education. It presents the findings of a study evaluating the effects of a specific gamification element (badges) on the engagement of five students with special learning needs, through online courses developed on the Moodle Learning Management System (LMS).…

  10. Pupil's motivation in the 3. grades for required reading and The Reading Badge

    OpenAIRE

    Logar, Renata

    2013-01-01

    Reading is extremely important for pupils and their development. The pupil with reading habits riches his vocabulary and gaining knowledge. On the other hand the pupil through reading entry into the world of imagination and stories. Major role in motivating students to read have parents and teachers. In this graduation thesis I was interested in how third grade teachers motivate their pupils to read. In doing so, I was focused mainly to reading for required reading and The Reading Badge. ...

  11. SSDL personel dosimetry system: migration from a client - server system into a web-based system

    International Nuclear Information System (INIS)

    Maizura Ibrahim; Rosnah Shariff; Ahmad Bazlie Abdul Kadir; John Konsoh Sangau; Mohd Amin Sharifuldin Salleh; Taiman Kadni; Noriah Mod Ali

    2007-01-01

    Personnel Dosimetry System has been used by the Secondary Standard Dosimetry Laboratory (SSDL), Nuclear Malaysia since ten years ago. The system is a computerized database system with a client-server concept. This system has been used by Film Badge Laboratory, SSDL to record details of clients, calculation of Film Badge dosage, management of radiation workers data's, generating of dosage report, retrieval of statistical reports regarding film badge usage for the purpose of reporting to monitoring bodies such as Atomic Energy Licensing Board (AELB), Ministry of Health and others. But, due to technical problems that frequently occurs, the system is going to be replaced by a newly developed web- based system called e-SSDL. This paper describe the problems that regularly occurs in the previous system, explains how the process of replacing the client-server system with a web-based system is done and the differences between the previous and current system. This paper will also present details architecture of the new system and the new process introduced in processing film badges. (Author)

  12. Noise origin of Co-Cr-Ta films on ultra-flat glass-ceramic and Si substrates for longitudinal recording disks

    International Nuclear Information System (INIS)

    Noda, Kohki; Kadokura, Sadao; Naoe, Masahiko

    2001-01-01

    Co 85 Cr 13 Ta 2 /Cr bilayered films for longitudinal recording disks were deposited by plasma-enhanced facing targets sputtering apparatus on 2.5 in and ultra-flat disk substrates of glass-ceramic and single-crystal silicon. Their noise and read/write characteristics were almost comparable with those of the high-performance disks using Co-Cr-Pt films, with coercivity H c of 2.4 kOe, as a reference disk, even though the Co-Cr-Ta films exhibited macroscopic H c of only 800 Oe. Co 85 Cr 13 Ta 2 films are known as low-noise media. This study addresses the problem of how to obtain low-noise media, using excellent sputtering apparatus and disk substrate materials, to allow practical applications in ultra-high-density recording systems, including 1 in microdrives for mobile applications

  13. Quality assurance of the manual OSLD Badge based personnel monitoring system

    International Nuclear Information System (INIS)

    Kumar, Munish; Gaonkar, U.P.; Koul, D.K.; Datta, D.; Singh, S.K.; Rakesh, R.B.; Kulkarni, M.S.; Ratna, P.

    2018-01-01

    Optically stimulated luminescence (OSL) based technique is widely used for monitoring of radiation workers exposed to x, gamma and beta radiations. Features such as multiple readout, short processing time, better beta response, absence of infra red signal (no heating), flexibility in the dosimeter design using binders or substrates having low melting point are associated advantages. Presently α-Al 2 O 3 :C and BeO based dosimeters are popularly used for personnel monitoring applications worldwide. The present paper describe results of the external quality control check (QAC) tests performed for the present OSLD badge based personnel monitoring system. The results were analyzed as per ANSI criteria and Trumpet curve methods

  14. The critical properties of magnetic films

    International Nuclear Information System (INIS)

    Saber, M.; Ainane, A.; Essaoudi, I.; Miguel, J.J. de

    2010-01-01

    Within the framework of the transverse spin-1/2 Ising model and by using the effective field theory with a probability distribution technique that accounts for the self spin correlations, we have studied the critical properties of an L-layer film of simple cubic symmetry in which the exchanges strength are assumed to be different from the bulk values in N S surface layers. We derive and illustrate the expressions for the phase diagrams, order parameter profiles and susceptibility. In such films, the critical temperature can shift to either lower or higher temperature compared with the corresponding bulk value. We calculate also some magnetic properties of the film, such as the layer magnetizations, their averages and their profiles and the longitudinal susceptibility of the film. The film longitudinal susceptibility still diverges at the film critical temperature as does the bulk longitudinal susceptibility.

  15. UV dosimetry in Antarctica (Baia Terranova): analysis of data from polysulphone films and GUV 511 radiometer

    Science.gov (United States)

    Mariutti, Gianni F.; Bortolin, Emanuela; Polichetti, Alessandro; Anav, Andrea; Casale, Giuseppe R.; Di Menno, Massimo; Rafanelli, Claudio

    2003-11-01

    This paper shows the results of measurements carried out in November 2002 in the Italian Antarctic Base of Baia Terranova (74.07°S, 164.08°E) to test polysulphone film badges as possible UV personal dosimeters in such extreme environmental conditions. In the Italian Antarctic Base a multichannel radiometer GUV 511 (Biospherical Inc.) is routinely used by the Italian National Research Council (CNR) for UV irradiance at sea level. This instrument measures the intensity of the solar UV spectrum at four different wavelengths: 305, 320, 340, 380 nm, respectively. Data obtained from polysulphone badges exposed in the horizontal and the vertical configurations during diverse time lapses of the day, and from polysulphone badges worn by three volunteers of the base staff during several outdoors activities, have been compared with the irradiance data calculated from the measured values of GUV 511. A preliminary analysis of the whole data, also in the light of other recorded atmospheric and climatic parameters, shows a reasonable consistency. As also shown by previous measurements, carried out in June 2002 in the locality of Ny Alesund (Svalbard -- Artic Region), the calibration of the above mentioned personal dosimeters by means of another instrument operating in the same locality is a crucial step. Further work is required to demonstrate this approach is suitable for an acceptable evaluation of personal radiant exposures.

  16. Computerized assessment of the measurement of individual doses

    International Nuclear Information System (INIS)

    Kiibus, A.

    1981-06-01

    The department for the measurements of individual doses makes regular dose controls by means of film badges for approximately 14000 individuals. The operation is facilitated by a Honeywell Bull Mini 6 Mod 43 computer. The computer language is COBOL applied to registering of in-data such as delivery of badges, film development, calibration, invoices, recording of individual doses and customers. The print-out consists of customers, badge codes, dosimeter lists, development specifications, dose statements, addresses, bills, dose statistics and the register of individuals. As a consequence of charges the activity is financially self-supporting. (G.B.)

  17. Effects of the Boy Scouts of America Personal Fitness Merit Badge on Cardio-Metabolic Risk, Health Related Fitness and Physical Activity in Adolescent Boys.

    Science.gov (United States)

    Maxwell, Justin; Burns, Ryan D; Brusseau, Timothy A

    2017-01-01

    A growing number of adolescents are more sedentary and have fewer formal opportunities to participate in physical activity. With the mounting evidence that sedentary time has a negative impact on cardiometabolic profiles, health related fitness and physical activity, there is a pressing need to find an affordable adolescent physical activity intervention. One possible intervention that has been overlooked in the past is Boy Scouts of America. There are nearly 900,000 adolescent boys who participate in Boy Scouts in the United States. The purpose of this research study was to evaluate the effect of the Personal Fitness merit badge system on physical activity, health-related fitness, and cardio-metabolic blood profiles in Boy Scouts 11-17 years of age. Participants were fourteen (N = 14) Boy Scouts from the Great Salt Lake Council of the Boy Scouts of America who earned their Personal Fitness merit badge. Classes were held in the Spring of 2016 where boys received the information needed to obtain the merit badge and data were collected. Results from the related-samples Wilcoxon signed rank test showed that the median of differences between VO 2 peak pre-test and post-test scores were statistically significant ( p = 0.004). However, it also showed that the differences between the Pre-MetS (metabolic syndrome) and Post-MetS scores (p = 0.917), average steps taken per day ( p = 0.317), and BMI ( p = 0.419) were not statistically significant. In conclusion, the merit badge program had a positive impact on cardiovascular endurance, suggesting this program has potential to improve cardiovascular fitness and should be considered for boys participating in Boy Scouts.

  18. Effects of the Badge Mechanism on Self-Efficacy and Learning Performance in a Game-Based English Learning Environment

    Science.gov (United States)

    Yang, Jie Chi; Quadir, Benazir; Chen, Nian-Shing

    2016-01-01

    A growing number of studies have been conducted on digital game-based learning (DGBL). However, there has been a lack of attention paid to individuals' self-efficacy and learning performance in the implementation of DGBL. This study therefore investigated how the badge mechanism in DGBL enhanced users' self-efficacy in the subject domain of…

  19. Situation of radiation exposure in medical personnel, (2)

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Minoru; Kumazaki, Hiroshi; Tsuchiya, Mitsuaki; Nakamura, Masamoto; Nonomura, Takuo [Tokyo Metropolitan Isotope Research Center (Japan)

    1982-09-01

    In connection with the radiation protection for medical personnel, the logarithmic normal distribution of their exposure doses has been examined, which is a prerequisite for the practice. The data were the doses measured by film badges from April, 1976, to March, 1981, for physicians, radiation technicians and nurses. The dose measurement by film badges was carried out monthly, 12 times a year; the values given were mrem/year. For the probability distribution of exposure doses, the following items were surveyed: comparison between three types of the profession and the kinds of film badges, i.e. for X-ray and ..gamma..-ray, the linearity of the logarithmic normal distribution for the types of medical institution, and comparison in the linearity between Japan and other countries. The fitting to linearity was found to be very good.

  20. An international cooperation by using an all-encompassing passive radon monitor

    International Nuclear Information System (INIS)

    Tommasino, L.; Chen, J.; Falcomer, R.; Janik, M.; Kanda, R.; DeFelice, F.; Cardellini, F.; Trevisi, R.; Leonardi, F.; Magnoni, M.; Chiaberto, E.; Agnesod, G.; Ragani, M. Faure; Espinosa, G.; Golzarri, J.; Kozak, K.; Mazur, J.

    2017-01-01

    The recently developed radon film-badge makes it possible to measure radon indoors, in soil, in water and/or in aqueous media (e.g. mud). As a result of its wide response linearity, this monitor has been successfully used to measure radon in-water with concentrations from 10 to ∼10 000 Bq/L. By exploiting the unique characteristics of this badge, a mini-survey has been carried out by Health Canada in which radon in water was measured from 12 private wells, as well as in tap water originating from the Ottawa River. Due to the widespread interest of different laboratories in using these passive monitors, laboratories were provided with plastic films to construct their own badges by using in-house CR-39 detectors. Monitors were then irradiated by a known radon concentration at the National Institute of Radiation Metrology (ENEA) s radon chamber and sent back to each laboratory for processing and counting. Even though these laboratories have been using different etching- and counting procedures, the film-badge responses varied only within ∼12%. (authors)

  1. Calibration of TLD badge to photons of energies above 6 MeV encountered in nuclear reactors

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Bakshi, A.K.

    1999-01-01

    Response of CaSO 4 :Dy Teflon discs based TLD badge has been evaluated for radiation fields having photons of energy above 6 MeV, often encountered in nuclear power plants. Gamma ray response of the TLD disc under metal filter in the badge (used for evaluation of gamma ray doses) was found to increase by about 10% to photons above 6 MeV as compared to the response for reference calibration to 60 Co gamma rays. Response of discs under the open window and the plastic filter was found to be only 40-60% of that under metal filter. Thus, while measurement of whole body dose is not affected seriously, the estimation of beta dose in the mixed fields of high energy gamma rays and beta rays could be in serious error. In the above fields for situations having beta doses of about 1.65 times the gamma ray doses, the present use of dose evaluation will record beta dose as zero, a serious under estimation of beta ray doses. Study also provides an explanation to an anomalous situation where reading under window or plastic filter is much less than that under metal filter. These aspects of personal dosimetry need attention. (author)

  2. Experiences in the monitoring of radiation workers in industry and hospitals in the Philippines

    International Nuclear Information System (INIS)

    Mateo, A.J.

    1976-08-01

    The task of monitoring of radiation doses among radiation workers employed either in industry and hospitals in the Philippines is presently being undertaken by the Philippine Atomic Energy Commission. These radiation monitoring devices cover not only radioactive materials or sources but also x-ray machines. The most common dosimetry used is the film badge. This paper presents some of the experiences gained in the use of the film badge and other dosimeters

  3. AN INTERNATIONAL COOPERATION BY USING AN ALL-ENCOMPASSING PASSIVE RADON MONITOR.

    Science.gov (United States)

    Tommasino, L; Chen, J; Falcomer, R; Janik, M; Kanda, R; DeFelice, F; Cardellini, F; Trevisi, R; Leonardi, F; Magnoni, M; Chiaberto, E; Agnesod, G; Ragani, M Faure; Espinosa, G; Golzarri, J; Kozak, K; Mazur, J

    2017-11-01

    The recently developed radon film-badge makes it possible to measure radon indoors, in soil, in water and/or in aqueous media (e.g. mud). As a result of its wide response linearity, this monitor has been successfully used to measure radon in-water with concentrations from 10 to ~10 000 Bq/L. By exploiting the unique characteristics of this badge, a mini-survey has been carried out by Health Canada in which radon in water was measured from 12 private wells, as well as in tap water originating from the Ottawa River. Due to the widespread interest of different laboratories in using these passive monitors, laboratories were provided with plastic films to construct their own badges by using in-house CR-39 detectors. Monitors were then irradiated by a known radon concentration at the National Institute of Radiation Metrology (ENEA)'s radon chamber and sent back to each laboratory for processing and counting. Even though these laboratories have been using different etching- and counting-procedures, the film-badge responses varied only within ~12%. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  5. Contact instabilities of anisotropic and inhomogeneous soft elastic films

    Science.gov (United States)

    Tomar, Gaurav; Sharma, Ashutosh

    2012-02-01

    Anisotropy plays important roles in various biological phenomena such as adhesion of geckos and grasshoppers enabled by the attachment pods having hierarchical structures like thin longitudinal setae connected with threads mimicked by anisotropic films. We study the contact instability of a transversely isotropic thin elastic film when it comes in contact proximity of another surface. In the present study we investigate the contact stability of a thin incompressible transversely isotropic film by performing linear stability analysis. Based on the linear stability analysis, we show that an approaching contactor renders the film unstable. The critical wavelength of the instability is a function of the total film thickness and the ratio of the Young's modulus in the longitudinal direction and the shear modulus in the plane containing the longitudinal axis. We also analyze the stability of a thin gradient film that is elastically inhomogeneous across its thickness. Compared to a homogeneous elastic film, it becomes unstable with a longer wavelength when the film becomes softer in going from the surface to the substrate.

  6. Comparing Digital Badges-and-Points with Classroom Token Systems: Effects on Elementary School ESL Students' Classroom Behavior and English Learning

    Science.gov (United States)

    Homer, Ryan; Hew, Khe Foon; Tan, Cheng Yong

    2018-01-01

    This paper reports the findings of a field experiment that gamified the classroom experience of elementary school ESL students by implementing digital badges-and-points which students could earn by achieving specific behavioral and learning goals. Altogether, 120 children in eight different classes participated in this study. Four of the classes…

  7. Critical Current Properties in Longitudinal Magnetic Field of YBCO Superconductor with APC

    Science.gov (United States)

    Kido, R.; Kiuchi, M.; Otabe, E. S.; Matsushita, T.; Jha, A. K.; Matsumoto, K.

    The critical current density (Jc) properties of the Artificial Pinning Center (APC) introduced YBa2Cu3O7 (YBCO) films in the longitudinal magnetic field were measured. Y2O3 or Y2BaCuO5 (Y211) was introduced as APCs to YBCO, and YBCO films with APC were fabricated on SrTiO3 single crystal substrate. The sizes of Y2O3 and Y211 were 5-10 nm and 10-20 nm, respectively. As a result, Jc enhancement in the longitudinal magnetic field was observed in Y2O3 introduced YBCO films. However, it was not observed in Y211 introduced YBCO films. Therefore, it was considered that Jc properties in the longitudinal magnetic field were affected by introducing of small size APC, and it was necessary that APC does not disturb the current pathway in the superconductor.

  8. Radiation exposures of medical employes and its management

    International Nuclear Information System (INIS)

    Saegusa, Kenji; Arimizu, Noboru; Uchiyama, Akira.

    1982-01-01

    For the five years period from April, 1976, to March, 1981, the usage of film badges at the hospital of Chiba University is described as follows: the number of personnel using film badges, the distribution of radiation exposure dose, and the employes exposed beyond 500 mrem yearly in respective years, departments and professional types. The cumulative number of personnel was 2,476 (yearly average was 495). Professional types were physician, nurse, radiation technician, researcher, etc. The number of personnel using film badges has been increasing year after year; of which about 500, 70% are physicians. A cumulative total of the employes exposed exceeding 500 mrem yearly was 11, ten being physicians; the highest dose was 1,840 mrem. The average yearly exposure dose per person was the highest in radiation technicians (100 - 30 mrem/person/year), followed by physicians (50 - 24 mrem) and nurses (9 - 1 mrem). As a whole, the value was 45 - 20 mrem/person/year. (J.P.N.)

  9. The actual state and problems of radiation control in medical facilities

    International Nuclear Information System (INIS)

    Kaneko, Masao

    1978-01-01

    Utilization of radiation was started in university hospitals, but recently, the established general inspections come to be very popular among general hospitals. Numerous kinds of nuclides are utilized for a number of purposes in university hospitals, while the kinds of nuclides utilized in general hospitals are quite limited. Concerning radiation safety control, film badge method is most popular among personal exposure control methods, while the combinations of film badge and pocket chamber methods, and film badge and TLD methods are also adopted. In many general hospitals, however, the exposure control tools are not equipped. Many kinds of safety control devices are installed for general controls. The laws so far mainly regulated the standards of buildings and installations, but did not specify the standard for accommodating RI-administered patients, and the preventive measures to secondary exposure and pollution, which often causes careless control. Therefore, the preventive measures to secondary injuries are required. (Kobatake, H.)

  10. Radiation exposures of medical employees and its management

    Energy Technology Data Exchange (ETDEWEB)

    Saegusa, K; Arimizu, N [Chiba Univ. (Japan). School of Medicine; Uchiyama, A

    1982-03-01

    For the five years period from April, 1976, to March, 1981, the usage of film badges at the hospital of Chiba University is described as follows: the number of personnel using film badges, the distribution of radiation exposure dose, and the employees exposed beyond 500 mrem yearly in respective years, departments and professional types. The cumulative number of personnel was 2,476 (yearly average was 495). Professional types were physician, nurse, radiation technician, researcher, etc. The number of personnel using film badges has been increasing year after year; of which about 500, 70% are physicians. A cumulative total of the employees exposed exceeding 500 mrem yearly was 11, ten being physicians; the highest dose was 1,840 mrem. The average yearly exposure dose per person was the highest in radiation technicians (100 - 30 mrem/person/year), followed by physicians (50 - 24 mrem) and nurses (9 - 1 mrem). As a whole, the value was 45 - 20 mrem/person/year.

  11. A practical approach towards minimisation of latent image fading in personnel monitoring films

    International Nuclear Information System (INIS)

    Dhond, R.V.; Patel, P.H.; Shenoy, K.S.; Adtani, M.M.

    1980-01-01

    A serious drawback of the film badges used in personnel monitoring is the latent image fading often as high as 95% when they are subjected to extreme climatic conditions such as high humidities and temperatures. Current data on latent image fading in personnel monitoring films of various brands of manufacturers (Kodak, Agfa-Gevaert, Du Pont) are summarized. If individual film packs are hermitically sealed in polythene envelopes, fading is reduced to 20%. Studies were, therefore, conducted on Kodak type 2 films to observe the radiation response of films subjected alternatively to humid (20deg C and 90% r.h.) conditions for 8 hours and dry (20deg C and 30 to 40% r.h.) conditions for 16 hours with a view to find out a practicable and simple method to minimise the error due to fading. The films were then exposed to 600, 1200, 2400 and 4800 mR of radium-226 gammas after one week of storage and replaced in their experimental conditions. The films were processed after zero, one and two weeks of their storage in their respective conditions. Dose versus density curves of films were plotted. A fading less than 10% is shown for a storage period of two weeks. It is also suggested that films be kept in a desiccator having dry silica gel crystals during the periods when they are not being worn by the radiation workers. (M.G.B.)

  12. Determination of BPA, BPB, BPF, BADGE and BFDGE in canned energy drinks by molecularly imprinted polymer cleaning up and UPLC with fluorescence detection.

    Science.gov (United States)

    Gallo, Pasquale; Di Marco Pisciottano, Ilaria; Esposito, Francesco; Fasano, Evelina; Scognamiglio, Gelsomina; Mita, Gustavo Damiano; Cirillo, Teresa

    2017-04-01

    A new method for simultaneous determination of five bisphenols in canned energy drinks by UPLC with fluorescence detection, after clean up on molecularly imprinted polymers, is herein described. The method was validated at two concentration levels, calculating trueness, repeatability and within-laboratory reproducibility, specificity, linearity of detector response, the limits of quantifications and the limits of detection for each bisphenol. The method is specific, reliable and very sensitive, allowing for determination of bisphenol F diglycidyl ether (BFDGE), bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF) and bisphenol A diglycidyl ether (BADGE) down to 0.50ng/mL; it was employed to determine contamination levels from these bisphenols in forty energy drinks of different brands, collected from the market in Naples. BPA was detected in 17 out of 40 samples (42.5%); in some energy drinks also BPF, BADGE and BFDGE were determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Anomalous Hall effect in polycrystalline Ni films

    KAUST Repository

    Guo, Zaibing

    2012-02-01

    We systematically studied the anomalous Hall effect in a series of polycrystalline Ni films with thickness ranging from 4 to 200 nm. It is found that both the longitudinal and anomalous Hall resistivity increased greatly as film thickness decreased. This enhancement should be related to the surface scattering. In the ultrathin films (46 nm thick), weak localization corrections to anomalous Hall conductivity were studied. The granular model, taking into account the dominated intergranular tunneling, has been employed to explain this phenomenon, which can explain the weak dependence of anomalous Hall resistivity on longitudinal resistivity as well. © 2011 Elsevier Ltd. All rights reserved.

  14. A LC-MS/MS method for the determination of BADGE-related and BFDGE-related compounds in canned fish food samples based on the formation of [M+NH(4)](+) aducts.

    Science.gov (United States)

    Míguez, J; Herrero, C; Quintás, I; Rodríguez, C; Gigosos, P G; Mariz, O C

    2012-12-01

    A new and simple liquid chromatography tandem mass-spectrometry method for the determination of different bisphenol A (BPA) derivatives such as bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) and their reaction products with water and hydrochloric acid in different fish food products was developed. The extraction procedure and the chromatographic conditions were optimised for complex food matrices such as fish products. Food samples were homogenised and extracted with a 1:1 solution of acetonitrile-hexane, the solvent was eliminated in a N(2) stream and the extract was reconstituted with 0.5mL of a 0.01M solution of ammonium formate. The sample solution obtained was directly measured by LC-MS/MS without any further purification under the developed conditions. The use of a mobile phase composed by ammonium formate-methanol in a binary gradient mode produced [M+NH(4)](+) aducts for the different BADGEs and BFDGEs. These aduct's fragmentations were employed for the LC-MS/MS quantification of BPA derivatives in canned fish samples. The results of the validation were appropriate: the method was linear for BADGE and its hydrolysed derivatives up to 1000μgkg(-1), for the remaining compounds linearity achieved up to 100μgkg(-1). Quantification limits were in the range 2-10μgkg(-1). RSD (intra and inter-day) was 6-12% and the recovery was comprised between 89% and 109%. Under the optimised conditions, the chromatographic separation was performed in 8min per sample. The method was applied to the determination of BADGE, BFDGE and their reaction products in different samples of canned fish from Spanish origin. Migration results obtained were in compliance with the EU regulations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. SIRAD – Personal radiation detectors

    International Nuclear Information System (INIS)

    Alnawaf, Hani; Butson, Martin J.; Yu, Peter K.N.; Cheung, Tsang

    2011-01-01

    SIRAD badge dosimeters provide a visual qualitative measurement of exposure to radiation for mid range dose exposure. This is performed using an active radiochromic dosimeter in a transparent window, combined into a badge assembly. When irradiated, the badges active window turns blue, which can be matched against the given colour chart for a qualitative assessment of the exposure received. Two peaks in the absorption spectra located at 617 nm and 567 nm were found. When analysed with a common computer desktop scanner, the optical density response of the film to radiation exposure is non-linear but reproducible. The net OD of the film was 0.21 when exposed to 50cGyand 0.31 at 200 cGy exposure when irradiated with a 6 MV x-ray energy beam and analysed using a broad spectrum light source. These values reduced when exposed with kilovoltage x-rays with an approximate 30% reducing in sensitivity at 50 kVp. The film provides an adequate measurement and visually qualitative assessment of radiation exposure for levels in the range of 0–50 cGy.

  16. Thermal conductivity of oriented polymer films

    NARCIS (Netherlands)

    Nysten, B.; Gonry, P.; Issi, J.P.; Govaert, L.E.; Lemstra, P.J.; Tong, T.W.

    1994-01-01

    The effect of stretching on the thermal cond. of polyethylene (PE) films is presented and compared to results obtained previously for oriented polyacetylene films and PE fibers. As expected, the longitudinal thermal cond. increases with the stretching level and thermal cond. values comparable to

  17. Preparation and Pb(II Adsorption Properties of Crosslinked Pectin-Carboxymethyl Chitosan Film

    Directory of Open Access Journals (Sweden)

    Budi Hastuti

    2015-11-01

    Full Text Available A modified pectin has been synthesized by reacting/combining -OH group among pectin and chitosan with BADGE (Bisphenol A diglycidyl ether crosslinker agent. The structure and morphology of the new material were characterized by Fourier transform infrared (FTIR spectroscopy, scanning electron microscopy (SEM and X-ray Diffraction (XRD analysis. Thermogravimetric studies showed an improvement in thermal characteristic. Adsorption experiments were performed in batch processes; sorption isotherms and kinetics were also studied. The Langmuir and Freundlich adsorption isotherm models were applied to describe the isotherms and isotherm constants for the adsorption of Pb(II ion onto adsorbent pectin-carboxymethyl chitosan-BADGE (pec-CMC-BADGE. The dynamic study showed that the sorption process followed the second-order kinetic equation. Result indicated also that Pb(II ion uptake could be well described by the Langmuir and Freundlich adsorption model of pec-CMC-BADGE and CMC with DG° of 25.3 and 23.1 kJ mol-1,respectively, while that of pectin followed Freundlich isotherm with DG° of 16.6 kJ mol-1.

  18. Data processing of personnel exposure in TLD and film systems

    International Nuclear Information System (INIS)

    Lerner, A.; Liav, N.; Eisen, Y.

    1979-01-01

    The program for the processing and storage of data on the personnel irradiation exposure in Israel is built on the data base of the Weizmann Institute of Science; it is a general program suitable for both TLD and film dosimetry. The TSO system helped bring up-to-date the data of the various collections in an interactive way. The introduction of the TLD dosemeters in the badge service required certain changes in the thinking line - this because the TLD being a personal dosemeter is returned into service after having been deciphered. This demands following up the dosemeter when the worker moves from unit to unit or after he had finished his work. The program takes into account the internal exposures,too and conforms to the new recommendation published in ICRP-26. (B.G.)

  19. Personal Dosimetry for Radiation Workers Upgrading an Old Petroleum Oil Field

    International Nuclear Information System (INIS)

    Gomaa, M.A.M.

    2011-01-01

    Radiation protection consultations and services were carried out over the last 15 years in Egypt at several petroleum companies. Egypt issued its first NORM Regulation in 2000; this was subsequently modified in 2006. The main aim of the present work was to report dosimetric experience gained during the handling of contaminated equipment in the upgrading of an old oilfield. Optimization of radiation protection was carried out using lead blankets. Film badges were distributed to workers. Films were redistributed to personnel every few weeks. More than 700 film badges were distributed during the working period and workers' health surveillance was carried out, including complete blood analysis. For the 5 month period, individual doses were estimated. The average effective dose was less than 1 mSv. (author)

  20. Analysis on Longitudinal Dose according to Change of Field Width

    International Nuclear Information System (INIS)

    Jung, Won Seok; Shin, Ryung Mi; Oh, Byung Cheon; Jo, Jun Young; Kim, Gi Chul; Choi, Tae Gu; Back, Jong Geal

    2011-01-01

    To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  1. Radiation Protection Services Division: progress report for 1992-1993

    International Nuclear Information System (INIS)

    Massand, O.P.; Murthy, B.K.S.

    1994-01-01

    This report describes the work of the Radiation Protection Services Division during 1993, for implementation of radiation safety in all institutions in India using radiation sources in medical, industrial and research applications. It gives information about personnel monitoring using photographic film and TLD badges, neutron monitoring badges, advisory and licensing services, regulation, transport of radioactive materials and periodic protection survey. About 33 publications by the staff of the Division are also listed. (author). 4 tabs

  2. Calibration of the indium foil used for criticality accident dosimetry in the UCC-ND employee identification badge

    International Nuclear Information System (INIS)

    Ryan, M.T.; Butler, H.M.; Gupton, E.D.; Sims, C.S.

    1982-05-01

    The UCC-ND Employee Identification Badge contains an indium foil disc that is intended for use as a dosimetry screening device in the event of a criticality accident. While it is recognized that indium is not a precise mixed neutron-gamma dosimeter, its activation by neutrons provides adequate means for separating potentially exposed persons into three groups. These groups are: (1) personnel exposed below annual dose limits, (2) personnel exposed above annual dose limits but below 25 rem, and (3) personnel exposed above 25 rem. This screening procedure is designed to facilitate dosimeter processing in order to meet regulatory reporting requirements. A quick method of interpreting induced activity measurements is presented and discussed

  3. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    International Nuclear Information System (INIS)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-01-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.)

  4. Longitudinal tibial epiphyseal bracket in Nievergelt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Burnstein, M.I.; De Smet, A.A.; Breed, A.L.; Thomas, J.R.; Hafez, G.R.

    1989-04-01

    A patient is described with lower extremity mesomelic dwarfism associated with bilateral congenital elbow, hip, and knee dislocations. Rhomboid-shaped tibiae and delayed ossification of the primary fibular ossification centers were demonstrated at birth. Plain films and magnetic resonance imaging revealed that the tibial deformities were due to the presence of longitudinal epiphyseal brackets. These brackets were observed at surgery and confirmed histologically. Recognition of the longitudinal epiphyseal bracket and its relationship to the tibial deformities seen in this patient with Nievergelt syndrome is important for planning surgical treatment. (orig.).

  5. A Radiation Badge Survey for Family Members Living With Patients Treated With a 103Pd Permanent Breast Seed Implant

    International Nuclear Information System (INIS)

    Keller, Brian M.; Pignol, Jean-Philippe; Rakovitch, Eileen; Sankreacha, Raxa; O'Brien, Peter

    2008-01-01

    Purpose: Sixty-seven patients with early-stage breast cancer were treated in a Phase I/II clinical trial using a 103 Pd permanent breast seed implant as adjuvant radiotherapy after breast-conserving surgery. We report the dose received by family members living with these patients and compare measured doses with theoretical worst-case scenario estimates. Methods and Materials: Exposure-rate measurements were taken at 1 m from the patient by using a calibrated low-energy survey meter. Landauer (Landauer Inc., Glenwood, IL) Luxel badges, with sensitivity of 0.01 mSv, were given to family members to wear after the implantation. Badge readings for 33 spouses and 28 other family members were used to estimate effective doses, and these were compared with theory. Results: Average preimplantation planning target volume from computed tomography was 50.3 ml (range, 18.0-96.7 ml), and average preimplantation distance between the skin and the most anterior planning target volume margin was 0.57 cm. The average maximum exposure rate was measured to be 2.4 ± 1.1 mR/h, and average measured dose to a spouse was 0.99 ± 1.0 mSv. The calculated exposure rates and spousal doses using preimplantation computed tomography scan data overestimated those measured. Average measured family member dose (excluding spouses) was 0.20 ± 0.58 mSv. Conclusions: Based on measured and calculated spousal doses, a permanent breast seed implant using 103 Pd is safe for the public. However, it is recommended that extra precautions in the way of a breast patch be used when patients with an implant will be in the vicinity of toddlers or pregnant women

  6. Reducing Friction with a Liquid Film on the Body Surface

    Directory of Open Access Journals (Sweden)

    Nikolay Klyuev

    2018-03-01

    Full Text Available A flow of a thin layer of liquid is simulated on a flat surface of a body located in a stream of air. Liquid film on the surface of the body reduces frictional resistance and can be used as a boundary layer control element. The paper presents a mathematical model of the film flow on a half-plane, located at an angle to the horizon. The fluid flow is determined by the force of gravity and friction from the external air current. A model of an incompressible viscous fluid is used in the boundary-layer approximation. The terms of the motion equation are averaged over the film thickness according to the Leibniz rule. In the cross section of the film, a quadratic law is adopted for the distribution of the longitudinal velocity, taking into account friction on the film surface. An analytical solution of the problem is obtained in the form of series in powers of the small parameter for determining the film thickness and the average longitudinal velocity along the length of the plate. It is shown that the friction decreases with flow around a half-plane with a film of liquid on the surface.

  7. Beta response of CaSO4:Dy based TLD badge and its angular dependence studies for personnel monitoring applications

    International Nuclear Information System (INIS)

    Kumar, Munish; Rakesh, R.B.; Sneha, C.; Ratna, P.; Bakshi, A.K.; Datta, D.

    2016-01-01

    In India, shallow/skin doses received by radiation workers from beta particles are measured using CaSO 4 :Dy based Teflon embedded TLD badge. The beta particles having maximum energy E max > 0.6 MeV - ≥ 3.54 MeV are monitored. The ratio of the response of discs under open and plastic regions (D Open/ D Perspex ) is used to estimate the energy of the beta source and to apply response correction factor. This is required as the disc dosimeters are thick and exhibit energy dependent response. Due to lack of comprehensive information regarding disc ratios and associated beta multiplication/response correction factors, present study was performed

  8. Digital dosimetry and personal and environmental monitoring assembly

    International Nuclear Information System (INIS)

    Cerovac, Z.; Radalj, Z.; Prlic, I.; Cerovac, H.

    1996-01-01

    Film+TLD and film or TLD Dosimetry have a certain delay in dose reporting, since the reports on occupational doses are usually available to the users within 40 days after the actual exposure. This is particularly important when the dose is received within the short-time interval or when the radiation source has some technical failures. For this reason, the additional monitoring is recommendable. The common Dosimetry service in Croatia is well established and the data available shows that over 80% of occupationally exposed persons are working in medical facilities, mainly with x-ray sources. Dosimetry services in the country are providing three types of dosemeters, film dosemeter badge, film+TLD dosemeter badge or plane TLD badge. We have decided to introduce the palette of digital pocket dosemeters to be used at different workplaces occupationally exposed to ionizing radiation. After the first experience with the ALARA 1G digital dosemeter it came out that this type of ionizing radiation measuring device is suitable for the various non-occupational purposes. After some technical improvement and with some telecommunication electronics this device is usable as a point environmental measuring station. This means that the probe of the record any change in normal environmental radiation field, send the data to the central station and to raise alarm if necessary. That is why we have made a prototype for environmental monitoring able to be connected to any kind of telecommunication net. (author)

  9. Electrical transport properties in Co nanocluster-assembled granular film

    Science.gov (United States)

    Zhang, Qin-Fu; Wang, Lai-Sen; Wang, Xiong-Zhi; Zheng, Hong-Fei; Liu, Xiang; Xie, Jia; Qiu, Yu-Long; Chen, Yuanzhi; Peng, Dong-Liang

    2017-03-01

    A Co nanocluster-assembled granular film with three-dimensional cross-connection paralleled conductive paths was fabricated by using the plasma-gas-condensation method in a vacuum environment. The temperature-dependent longitudinal resistivity and anomalous Hall effect of this new type granular film were systematically studied. The longitudinal resistivity of the Co nanocluster-assembled granular film first decreased and then increased with increasing measuring temperature, revealing a minimum value at certain temperature, T min . In a low temperature region ( T governed the electrical transport process, and the temperature coefficient of resistance (TCR) showed an insulator-type behavior. The thermal fluctuation-induced tunneling conduction progressively increased with increasing temperature, which led to a decrease in the longitudinal resistivity. In a high temperature region, the TCR showed a metallic-type behavior, which was primarily attributed to the temperature-dependent scattering. Different from the longitudinal resistivity behavior, the saturated anomalous Hall resistivity increased monotonically with increasing measuring temperature. The value of the anomalous Hall coefficient ( R S ) reached 2.3 × 10-9 (Ω cm)/G at 300 K, which was about three orders of magnitude larger than previously reported in blocky single-crystal Co [E. N. Kondorskii, Sov. Phys. JETP 38, 977 (1974)]. Interestingly, the scaling relation ( ρx y A ∝ ρx x γ ) between saturated anomalous Hall resistivity ( ρx y A ) and longitudinal resistivity ( ρ x x ) was divided into two regions by T min . However, after excluding the contribution of tunneling, the scaling relation followed the same rule. The corresponding physical mechanism was also proposed to explain these phenomena.

  10. SAFETY: STRICTER CONTROLS IN CONTROLLED AREAS IN THE PS

    CERN Multimedia

    G. Daems

    2001-01-01

    The PS accelerators will soon stop for several months. Work will take place in controlled areas in the PS and will involve many people who are not always aware of the risks associated with the work sites. To guarentee the safety of these workers, the following two measures will be applied: everyone working in a controlled zone - Linacs, PSB, and PS machines tunnels, and transfer lines - must wear, visibly, his CERN access card and his film badge. the CERN access card and the film badge will only be issued after following a basic safety course. Regular checks will be carried out during the shutdown. Anyone without these two items on their person will be obliged to leave the area immediately.

  11. Extraordinary optical transmission through nonlocal holey metal films

    DEFF Research Database (Denmark)

    David, Christin; Christensen, Johan

    2017-01-01

    We investigate nonlocal electrodynamics based on the generalized hydrodynamic approach including electron diffusion in holey gold films, showing extraordinary optical transmission (EOT). Dramatic changes with respect to the local approximation for rather large film thicknesses t less than...... or similar to 100 nm impact both reflectance and absorbance at normal incidence. Beyond the familiar resonance blueshift with the decreasing film thickness, the interference of longitudinal pressure waves in the holey structure generates an unexpected oscillatory response with geometrical parameters...

  12. Longitudinal and transverse pyroelectric effects in a chiral ferroelectric liquid crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yablonskii, S. V., E-mail: yablonskii2005@yandex.ru; Bondarchuk, V. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Soto-Bustamante, E. A.; Romero-Hasler, P. N. [Universidad de Chile (Chile); Ozaki, M. [Osaka University, Department of Electronic Engineering, Faculty of Engineering (Japan); Yoshino, K. [Shimane Institute for Industrial Technology (Japan)

    2015-04-15

    In this study, we compare the results of experimental investigations of longitudinal and transverse pyroelectric effects in a chiral ferroelectric crystal. In a transverse geometry, we studied freely suspended liquid-crystal films. In both geometries, samples exhibited bistability, demonstrating stable pyroelectric signals of different polarities at zero voltage. It is shown that a bistable cell based on a freely suspended film requires 40 times less energy expenditures as compared to the conventional sandwich-type cell.

  13. Giant transversal particle diffusion in a longitudinal magnetic ratchet.

    Science.gov (United States)

    Tierno, Pietro; Reimann, Peter; Johansen, Tom H; Sagués, Francesc

    2010-12-03

    We study the transversal motion of paramagnetic particles on a uniaxial garnet film, exhibiting a longitudinal ratchet effect in the presence of an oscillating magnetic field. Without the field, the thermal diffusion coefficient obtained by video microscopy is D(0) ≈ 3 × 10(-4)  μm2/s. With the field, the transversal diffusion exhibits a giant enhancement by almost four decades and a pronounced maximum as a function of the driving frequency. We explain the experimental findings with a theoretical interpretation in terms of random disorder effects within the magnetic film.

  14. Application of artificial neural network for development of an algorithm for TLD badge system in the mixed field dosimetry of X and gamma radiation in terms of Hp(10)

    International Nuclear Information System (INIS)

    Srivastava, K.; Bakshi, A.K.; Geetha, V.; Kher, R.K.; Dhar, V.K.

    2005-01-01

    ICRU has introduced new operational quantities for individual monitoring. Therefore it is required to develop an algorithm that gives direct response of the TLD badge in terms of the operational quantities. For this purpose and also to improve the precision in the mixed fields dosimetry, two methods were studied i)- analytical method by developing an algorithm based on of higher order polynomial fit of the data points for known delivered doses and ii) use of Artificial Neural Network (ANN). Study on the response of the TLD badge system based on CaSO 4 : Dy Teflon TLD discs in the mixed fields of X and gamma radiation in terms of operational quantity Hp(10) was carried out using the prevalent algorithm, algorithm developed using higher order polynomial and neural network predicted algorithm for different proportion of dose delivered by X and gamma radiations. It was found that the uncertainties in the dose response for few fields are beyond the acceptable limit for prevalent algorithm and within the acceptable limit for other two algorithms. Algorithm based on ANN gives higher precision in the mixed field of two radiations compared to other two algorithms. (author)

  15. Impact of a smoking ban in hospitality venues on second hand smoke exposure: a comparison of exposure assessment methods.

    Science.gov (United States)

    Rajkumar, Sarah; Huynh, Cong Khanh; Bauer, Georg F; Hoffmann, Susanne; Röösli, Martin

    2013-06-04

    In May 2010, Switzerland introduced a heterogeneous smoking ban in the hospitality sector. While the law leaves room for exceptions in some cantons, it is comprehensive in others. This longitudinal study uses different measurement methods to examine airborne nicotine levels in hospitality venues and the level of personal exposure of non-smoking hospitality workers before and after implementation of the law. Personal exposure to second hand smoke (SHS) was measured by three different methods. We compared a passive sampler called MoNIC (Monitor of NICotine) badge, to salivary cotinine and nicotine concentration as well as questionnaire data. Badges allowed the number of passively smoked cigarettes to be estimated. They were placed at the venues as well as distributed to the participants for personal measurements. To assess personal exposure at work, a time-weighted average of the workplace badge measurements was calculated. Prior to the ban, smoke-exposed hospitality venues yielded a mean badge value of 4.48 (95%-CI: 3.7 to 5.25; n = 214) cigarette equivalents/day. At follow-up, measurements in venues that had implemented a smoking ban significantly declined to an average of 0.31 (0.17 to 0.45; n = 37) (p = 0.001). Personal badge measurements also significantly decreased from an average of 2.18 (1.31-3.05 n = 53) to 0.25 (0.13-0.36; n = 41) (p = 0.001). Spearman rank correlations between badge exposure measures and salivary measures were small to moderate (0.3 at maximum). Nicotine levels significantly decreased in all types of hospitality venues after implementation of the smoking ban. In-depth analyses demonstrated that a time-weighted average of the workplace badge measurements represented typical personal SHS exposure at work more reliably than personal exposure measures such as salivary cotinine and nicotine.

  16. Occupational exposure to radiation in the United Kingdom and its contribution to the genetically effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Binks, W; Marley, W G

    1960-12-01

    It is now the common practice in the United Kingdom for persons who are exposed occupationally to ionizing radiations to be subjected to continuous individual monitoring in order to ensure that the doses that they receive from sources external to the body do not exceed the levels which are regarded as acceptable. In the operation of large-scale monitoring services such as are provided by the Radiological Protection Service (R.P.S.) and by the establishments of the United Kingdom Atomic Energy Authority (U.K.A.E.A.) there is no satisfactory alternative to the use of photographic film, bearing in mind such aspects as simplicity, reliability, accuracy, cheapness, ease of postal transmission of the films in the special holders, and availability of a durable record of the dose received. The Radiological Protection Service provides a film badge service which is widely used by industry. This organization also provides film badges for about one-third of the occupationally exposed persons in National Health Service hospitals; for the remaining hospital workers the majority of establishments undertake their own monitoring arrangements. The United Kingdom Atomic Energy Authority provides its own film badge services for all exposed workers. It is the purpose of this report to summarize the information obtained by the R.P.S. and the U.K.A.E.A. regarding the doses received by occupationally exposed persons. The total genetically effective dose received by the population from occupational exposure is also compared with that received from natural background radiation. This report also summarizes the measurements made by the R.P.S. and the U.K.A.E.A. to check the internal contamination of the body in cases where radioactivity has been ingested or inhaled.

  17. Occupational exposure to radiation in the United Kingdom and its contribution to the genetically effective dose

    International Nuclear Information System (INIS)

    Binks, W.; Marley, W.G.

    1960-01-01

    It is now the common practice in the United Kingdom for persons who are exposed occupationally to ionizing radiations to be subjected to continuous individual monitoring in order to ensure that the doses that they receive from sources external to the body do not exceed the levels which are regarded as acceptable. In the operation of large-scale monitoring services such as are provided by the Radiological Protection Service (R.P.S.) and by the establishments of the United Kingdom Atomic Energy Authority (U.K.A.E.A.) there is no satisfactory alternative to the use of photographic film, bearing in mind such aspects as simplicity, reliability, accuracy, cheapness, ease of postal transmission of the films in the special holders, and availability of a durable record of the dose received. The Radiological Protection Service provides a film badge service which is widely used by industry. This organization also provides film badges for about one-third of the occupationally exposed persons in National Health Service hospitals; for the remaining hospital workers the majority of establishments undertake their own monitoring arrangements. The United Kingdom Atomic Energy Authority provides its own film badge services for all exposed workers. It is the purpose of this report to summarize the information obtained by the R.P.S. and the U.K.A.E.A. regarding the doses received by occupationally exposed persons. The total genetically effective dose received by the population from occupational exposure is also compared with that received from natural background radiation. This report also summarizes the measurements made by the R.P.S. and the U.K.A.E.A. to check the internal contamination of the body in cases where radioactivity has been ingested or inhaled

  18. Assessment of dose to the expected overexposed radiation workers in Malaysia using dicentric technique from 2005 - 2006

    International Nuclear Information System (INIS)

    Noraisyah Mohd Yusof; Mohd Rodzi Ali; Noriah Jamal; Rehir Dahalan

    2008-08-01

    Malaysian Nuclear Agency is recognized by the Atomic Energy Licensing Board (AELB) as a National Biodosimetry Laboratory for performing the chromosome aberration tests in Malaysia. The test is to be done for radiation workers who received doses of more than the annual dose limit of 50 mSv or losses of film badge. This paper aims at presenting results of assessment of dose to the expected overexposed radiation workers in Malaysia using dicentric technique from year 2005 to 2006. Between that period of time, 20 blood samples (loss of film badge: 5 samples, overexposed: 13 samples and follow-up cases: 2 samples) were received from the AELB and the assessment of chromosome aberration were performed. The information on whole body exposure (WBE) was also received together with the samples for overexposed worker. We used the gold standard technique, which is the dicentric assay to analyze the blood samples. The technique is described in the IAEA Technical Report Series No. 405. The results were then analyzed and compared with the respective WBE for the overexposed worker. We found that no doses were observed for workers who loss their film badges and for follow-up cases. 30.8% of the overexposed workers show doses of more than 50 mSv. However, 69.2% shows doses lower than the annual limit. Variation of results may be due to delayed blood sampling from the workers. This technique is especially useful for immediate assessment of radiation exposure. (Author)

  19. Structural, magnetic and transport properties of Co2FeAl Heusler films with varying thickness

    International Nuclear Information System (INIS)

    Wang, Xiaotian; Li, Yueqing; Du, Yin; Dai, Xuefang; Liu, Guodong; Liu, Enke; Liu, Zhongyuan; Wang, Wenhong; Wu, Guangheng

    2014-01-01

    We report on a systematic study of the structural, magnetic properties and the anomalous Hall effect, in the Heusler alloy Co 2 FeAl (CFA) epitaxial films on MgO (001), as a function of film thickness. It was found that the epitaxial CFA films show a highly ordered B2 structure with an in-plane uniaxial magnetic anisotropy. The electrical transport properties reveal that the lattice and magnon scattering contributions to the longitudinal resistivity. Independent on the thickness of films, the anomalous Hall resistivity of CFA films is found to be dominated by skew scattering only. Moreover, the anomalous Hall resistivity shows weakly temperature dependent behavior, and its absolute value increases as the thickness decreases. We attribute this temperature insensitivity in the anomalous Hall resistivity to the weak temperature dependent of tunneling spin-polarization in the CFA films, while the thickness dependence behavior is likely due to the increasing significance of interface or free surface electronic states. - Highlights: ●Highly ordered CFA films with various thicknesses were prepared on MgO substrates. ●The magnon scattering contributions to the longitudinal resistivity in the CFA films. ●The anomalous Hall resistivity of the CFA films shows weakly temperature dependent. ●The CFA films show weak temperature dependent of tunneling spin-polarization

  20. Acoustic phonon dynamics in thin-films of the topological insulator Bi2Se3

    International Nuclear Information System (INIS)

    Glinka, Yuri D.; Babakiray, Sercan; Johnson, Trent A.; Holcomb, Mikel B.; Lederman, David

    2015-01-01

    Transient reflectivity traces measured for nanometer-sized films (6–40 nm) of the topological insulator Bi 2 Se 3 revealed GHz-range oscillations driven within the relaxation of hot carriers photoexcited with ultrashort (∼100 fs) laser pulses of 1.51 eV photon energy. These oscillations have been suggested to result from acoustic phonon dynamics, including coherent longitudinal acoustic phonons in the form of standing acoustic waves. An increase of oscillation frequency from ∼35 to ∼70 GHz with decreasing film thickness from 40 to 15 nm was attributed to the interplay between two different regimes employing traveling-acoustic-waves for films thicker than 40 nm and the film bulk acoustic wave resonator (FBAWR) modes for films thinner than 40 nm. The amplitude of oscillations decays rapidly for films below 15 nm thick when the indirect intersurface coupling in Bi 2 Se 3 films switches the FBAWR regime to that of the Lamb wave excitation. The frequency range of coherent longitudinal acoustic phonons is in good agreement with elastic properties of Bi 2 Se 3

  1. Leukemia among participants in military maneuvers at a nuclear bomb test

    International Nuclear Information System (INIS)

    Caldwell, G.G.; Kelley, D.B.; Heath, C.W. Jr.

    1980-01-01

    Preliminary studies indicate that nine cases of leukemia have occurred among 3224 men who participated in military maneuvers during the 1957 nuclear test explosion Smoky. This represents a significant increase over the expected incidence of 3.5 cases. They included four cases of acute myelocytic leukemia, three of chronic myelocytic leukemia, and one each of hairy cell and acute lymphocytic leukemia. At time of diagnosis, patient ages ranged from 21 to 60 years (mean, 41.8 years) and the interval from time of nuclear test to diagnosis from two to 19 years (mean, 14.2 years). Film-badge records, which are available for eight of the nine men, indicated gamma radiation exposure levels ranging from 0 to 2977 mrem (mean, 1033 mrem). Mean film-badge gamma dose for the entire Smoky cohort was 466.2 mrem

  2. Survey of medical radium installations in Wisconsin

    International Nuclear Information System (INIS)

    Tapert, A.C.; Lea, W.L.

    1975-05-01

    A radiation protection survey was performed at 70 medical radium installations in the State of Wisconsin. The requirements of the State's Radiation Protection Code were used as survey criteria. Radiation measurements of radium storage containers, radium capsule leakage tests, and monitoring of work surfaces for contamination were performed. Film badge monitoring data of whole body and extremity doses are presented for 221 individuals at 17 hospitals. Whole body doses during single treatments ranged from 10 to 1360 mrems per individual. The estimate of 500 mrems per treatment was determined as the dose aggregate to hospital personnel. Whole body doses from film badges are compared with analogous TLD doses. Four physicians and six technicians at nine hospitals participated in a study for monitoring the extremities with TLD. Cumulative extremity doses ranged from 28 to 6628 mrems per participant during the study. (U.S.)

  3. Infrared reflectance measurement for InN thin film characterization

    International Nuclear Information System (INIS)

    Fukui, K.; Kugumiya, Y.; Nakagawa, N.; Yamamoto, A.

    2006-01-01

    Infrared reflectance measurements of a series of InN thin films have been performed and attempt to derive carrier concentration and other physical constants for InN thin film characterization. Fitting calculations are performed by use of the dielectric function equation based on phonon-plasmon coupling model. Longitudinal and transverse optical phonon frequencies, plasma frequency and their damping parameters can be derived from fitting. From those results, electrical and phonon properties of InN and characterization of films are discussed. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. Division of Radiological Protection : progress report, 1989-1991

    International Nuclear Information System (INIS)

    Gupta, B.L.; Nagarajan, P.S.; Bhatt, B.C.; Seethapathy, A.; Pradhan, A.S.; Vishwakarma, R.R.

    1992-01-01

    This report describes the work of the Division of Radiological Protection during 1989-91, for implementation of radiation safety in all institutions in the country using radiation sources for medical, industrial and research applications. It gives information about personnel monitoring using photographic film and TLD badges, neutron monitoring badges, dosimetric techniques developed, calibration techniques for high-dose irradiators, design and fabrication of special radiation protection instruments, advisory and licensing services, regulation and transport of radioactive materials, periodic protection survey, education and training related to radiation safety programmes. About 164 publications by the staff of this Division are listed. (author). 1 index., 1 tab

  5. Liquid film characterization in horizontal, annular, two-phase, gas-liquid flow using time-resolved laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Farias, P.S.C.; Martins, F.J.W.A.; Azevedo, L.F.A. [PUC-Rio, Department of Mechanical Engineering, Rio de Janeiro (Brazil); Sampaio, L.E.B. [LMTA/PGMEC, UFF, Department of Mechanical Engineering, Laboratory of Theoretical and Applied Mechanics, Rio de Janeiro (Brazil); Serfaty, R. [Petrobras R and D Center, Rio de Janeiro (Brazil)

    2012-03-15

    A non-intrusive optical technique was developed to provide time-resolved longitudinal and cross-sectional images of the liquid film in horizontal annular pipe flow of air and water, revealing the interfacial wave behavior. Quantitative information on the liquid film dynamics was extracted from the time-resolved images. The planar laser-induced fluorescence technique was utilized to allow for optical separation of the light emitted by the film from that scattered by the air-water interface. The visualization test section was fabricated from a tube presenting nearly the same refractive index as water, which allowed the visualization of the liquid film at regions very close to the pipe wall. Longitudinal images of the liquid film were captured using a high-frame-rate digital video camera synchronized with a high-repetition-rate laser. An image processing algorithm was developed to automatically detect the position of the air-water interface in each image frame. The thickness of the liquid film was measured at two axial stations in each processed image frame, providing time history records of the film thickness at two different positions. Wave frequency information was obtained by analyzing the time-dependent signals of film thickness for each of the two axial positions recorded. Wave velocities were measured by cross-correlating the amplitude signals from the two axial positions. For the film cross-section observations, two high-speed digital video cameras were used in a stereoscopic arrangement. Comparisons with results from different techniques available in literature indicate that the technique developed presents equivalent accuracy in measuring the liquid film properties. Time-resolved images of longitudinal and cross-section views of the film were recorded, which constitute valuable information provided by the technique implemented. (orig.)

  6. Structural, magnetic and transport properties of Co{sub 2}FeAl Heusler films with varying thickness

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaotian [School of Material Sciences and Engineering, Hebei University Technology, Tianjin 300130 (China); Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Li, Yueqing [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); State Key Laboratory of Metastable Material Sciences and Technology, Yanshan University, Qinhuangdao 066004 (China); Du, Yin [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Dai, Xuefang; Liu, Guodong [School of Material Sciences and Engineering, Hebei University Technology, Tianjin 300130 (China); Liu, Enke [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Liu, Zhongyuan [State Key Laboratory of Metastable Material Sciences and Technology, Yanshan University, Qinhuangdao 066004 (China); Wang, Wenhong, E-mail: wenhong.wang@iphy.ac.cn [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Wu, Guangheng [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-08-01

    We report on a systematic study of the structural, magnetic properties and the anomalous Hall effect, in the Heusler alloy Co{sub 2}FeAl (CFA) epitaxial films on MgO (001), as a function of film thickness. It was found that the epitaxial CFA films show a highly ordered B2 structure with an in-plane uniaxial magnetic anisotropy. The electrical transport properties reveal that the lattice and magnon scattering contributions to the longitudinal resistivity. Independent on the thickness of films, the anomalous Hall resistivity of CFA films is found to be dominated by skew scattering only. Moreover, the anomalous Hall resistivity shows weakly temperature dependent behavior, and its absolute value increases as the thickness decreases. We attribute this temperature insensitivity in the anomalous Hall resistivity to the weak temperature dependent of tunneling spin-polarization in the CFA films, while the thickness dependence behavior is likely due to the increasing significance of interface or free surface electronic states. - Highlights: ●Highly ordered CFA films with various thicknesses were prepared on MgO substrates. ●The magnon scattering contributions to the longitudinal resistivity in the CFA films. ●The anomalous Hall resistivity of the CFA films shows weakly temperature dependent. ●The CFA films show weak temperature dependent of tunneling spin-polarization.

  7. Personal exposure control using TLD

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu; Takeda, Shinso

    1979-01-01

    In the Tokai Works of the Power Reactor and Nuclear Fuel Development Corporation (PNC), for personal exposure control, the switching from film badges to TLD badges (and also finger-ring type local dosimeters) was made in fiscal 1974. The facilities involved are a fuel reprocessing plant, a PuO 2 -UO 2 mixed fuel production facility, and a centrifugal uranium enrichment development facility. The types of radiation concerned are various, such as γ(x), β and n. The situation of personal exposure control with TLD and the dose evaluation methods for respective radiations are explained. The number of personnel subject to exposure control, including transient people, is about 2500 - 3000 per three months. The TLD badges used are a special PNC type with TLDs to measure separately γ(x), β and n. With casings made of ABS resin, the external dimensions are 76 mm x 46 mm. (J.P.N.)

  8. Relation of planar Hall and planar Nernst effects in thin film permalloy

    Science.gov (United States)

    Wesenberg, D.; Hojem, A.; Bennet, R. K.; Zink, B. L.

    2018-06-01

    We present measurements of the planar Nernst effect (PNE) and the planar Hall effect (PHE) of nickel-iron (Ni–Fe) alloy thin films. We suspend the thin-film samples, measurement leads, and lithographically-defined heaters and thermometers on silicon-nitride membranes to greatly simplify control and measurement of thermal gradients essential to quantitative determination of magnetothermoelectric effects. Since these thermal isolation structures allow measurements of longitudinal thermopower, or the Seebeck coefficient, and four-wire electrical resistivity of the same thin film, we can quantitatively demonstrate the link between the longitudinal and transverse effects as a function of applied in-plane field and angle. Finite element thermal analysis of this essentially 2D structure allows more confident determination of the thermal gradient, which is reduced from the simplest assumptions due to the particular geometry of the membranes, which are more than 350 μm wide in order to maximize sensitivity to transverse thermoelectric effects. The resulting maximum values of the PNE and PHE coefficients for the Ni–Fe film with 80% Ni we study here are and , respectively. All signals are exclusively symmetry with applied field, ruling out long-distance spin transport effects. We also consider a Mott-like relation between the PNE and PHE, and use both this and the standard Mott relation to determine the energy-derivative of the resistivity at the Fermi energy to be , which is very similar to values for films we previously measured using similar thermal platforms. Finally, using an estimated value for the lead contribution to the longitudinal thermopower, we show that the anisotropic magnetoresistance (AMR) ratio in this Ni–Fe film is two times larger than the magnetothermopower ratio, which is the first evidence of a deviation from strict adherence to the Mott relation between Seebeck coefficient and resistivity.

  9. Tuning thermal conductivity in homoepitaxial SrTiO{sub 3} films via defects

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, Charles M. [Department of Materials Science and Engineering, Cornell University, Ithaca, New York 14853-1501 (United States); Department of Materials Science and Engineering, Pennsylvania State University, University Park, Pennsylvania 16802 (United States); Wilson, Richard B.; Cahill, David G. [Department of Materials Science and Engineering and Materials Research Laboratory, University of Illinois, Urbana, Illinois 61801 (United States); Schäfer, Anna; Schubert, Jürgen [Peter Grünberg Institute (PGI9-IT), JARA-Fundamentals of Future Information Technology, Research Centre Jülich, D-52425 Jülich (Germany); Mundy, Julia A.; Holtz, Megan E. [School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853 (United States); Muller, David A. [School of Applied and Engineering Physics, Cornell University, Ithaca, New York 14853 (United States); Kavli Institute at Cornell for Nanoscale Science, Ithaca, New York 14853 (United States); Schlom, Darrell G. [Department of Materials Science and Engineering, Cornell University, Ithaca, New York 14853-1501 (United States); Kavli Institute at Cornell for Nanoscale Science, Ithaca, New York 14853 (United States)

    2015-08-03

    We demonstrate the ability to tune the thermal conductivity of homoepitaxial SrTiO{sub 3} films deposited by reactive molecular-beam epitaxy by varying growth temperature, oxidation environment, and cation stoichiometry. Both point defects and planar defects decrease the longitudinal thermal conductivity (k{sub 33}), with the greatest decrease in films of the same composition observed for films containing planar defects oriented perpendicular to the direction of heat flow. The longitudinal thermal conductivity can be modified by as much as 80%—from 11.5 W m{sup −1}K{sup −1} for stoichiometric homoepitaxial SrTiO{sub 3} to 2 W m{sup −1}K{sup −1} for strontium-rich homoepitaxial Sr{sub 1+δ}TiO{sub x} films—by incorporating (SrO){sub 2} Ruddlesden-Popper planar defects.

  10. Visualization of Longitudinal and Transverse Components of Strongly Focused Optical Field by means of Photo-Reactive Azopolymers

    Directory of Open Access Journals (Sweden)

    Kharitonov A.V.

    2015-01-01

    Full Text Available Most important problems in modern photonics are fabrication, visualization and characterization of nanomaterials at optical frequencies. A number of optical techniques uses tightly focused laser beams to access longitudinal electromagnetic fields, which are directed towards the wave vector. In this Letter, the distribution of transverse and longitudinal optical fields in tightly focused laser beams, polarized in a new fashion, is investigated. Polarization dependent fingerprints of transverse and longitudinal optical fields are experimentally captured by means of photoinduced surface deformations in azobenzene polymer thin films.

  11. Design and construction of a personal radiation monitor

    International Nuclear Information System (INIS)

    Oliveira, A.H. de.

    1979-01-01

    The design and construction of a personal radiation monitor is dealt with. It provides a direct and reliable reading of the received dose, and sounds an alarm in the event of an excessive dose rate. A detailed analysis of its design, construction and caracteristics is given, as well a comparison with usual dosimeters. The apparatus is based on large-scale integrated electronics, it is reliable, easy to read, and can be used in the same manner as a film-badge. Contrariwise to both the film-badge and the termoluminescent dosimeters, it allows a direct reading. Also, it is not susceptible to false readings due to mechanical shocks, which is the weak point of the pocket ionization chamber. The dosimeter described herein is equipped with a special corrective shield that gives the correct dose reading, regardless of the photon energy. It is also highly immune to neutron interference. (Author) [pt

  12. Exposure of Medical Staff during Interventional Procedures

    International Nuclear Information System (INIS)

    Osvay, M.; Turak, O.

    2013-01-01

    The medical staff during interventional procedures receives significant doses on their hands, or parts of their body not covered with protective shielding equipment, as they are close to X-rays field. It can be stated, that interventional radiology and cardiology have one of the highest doses among the X-ray diagnostic procedures. The radiologist use X-ray machine directly in the interventional procedures. The occupational dose is measured only by one Kodak film badge worn under the lead apron for the estimation of the effective dose in Hungary. Our lecture presents the results of dose measurements on eye lens, hands, knees using LiF thermoluminescent dosemeters on the medical staff of two Hungarian hospitals. Results suggest that wearing only one film badge (or other dosemeter system) under the lead apron does not provide proper information on the real occupational dose of medical staff.(author)

  13. Investigation of the magnetic properties of electrodeposited NiFe thin films

    International Nuclear Information System (INIS)

    Bakkaloglu, O. F.; Bedir, M.; Oeztas, M.; Karahan, I. H.

    2002-01-01

    Most magnetic devices used today are based on the magnetic thin film. Rapid and extensive developments in magnetic sensor / actuator and magnetic recording technology place a growing demand on the use of different thin film fabrication techniques for magnetic materials. The electroplating technique is especially interesting due to its low cost, high throughput and high quality of the deposits which are extensively used in the magnetic recording industry to deposit relatively thick permalloy layers. Much recent attention has focused on the electrodeposited NiFe thin films, which exhibit giant magneto resistive behaviour as well as anisotropic magnetoresistance properties. n this study, NiFe thin films were developed by using electrodeposition technique and their crystallinity structures were investigated by using x-ray diffractometer measurements. The magneto resistive properties of the samples were investigated by Wan der Pauw method with a home made electromagnet under the different magnetic fields. The magnetoresistance measurements of the samples were carried out in two configurations; current parallel ( longitudinal ) and perpendicular ( transverse ) to the magnetic field. In the longitudinal configuration giant magnetoresistance was observed while anisotropic magnetoresistance was detected in the other configuration

  14. Solar UVR exposures of three groups of outdoor workers on the Sunshine Coast, Queensland

    International Nuclear Information System (INIS)

    Gies, H.P.; Roy, C.R.; Toomey, S.; MacLennan, R.; Watson, M.

    1995-01-01

    The solar ultraviolet radiation (UVR) exposures of three groups of outdoor workers, physical education (PE) teachers, ground staff/gardeners and lifeguards were measured using UVR-sensitive polysulfone (PS) film badges. The exposures all took place on the Sunshine Coast, Queensland over 5 consecutive weekdays in November 1992. For the three groups, the shoulder badges received greater UVR exposures than the chest badges, in agreement with previous studies. The PE teachers received the highest UVR exposures while the lifeguards received the least. One of the 5 days of the study was overcast with some rain showers and UVR doses for this day for all groups was significantly lower than on the other 4 days, however the ratio of exposure to ambient remained relatively constant. All groups had measured UVR exposures in excess of occupational guidelines, indicating that protective measures, including education and behaviour modification, which are becoming much more common in occupational situations in Australia, are both timely and necessary. (author)

  15. Pre-school reading badge called "Iridescent Little Fish" and its impact on reading habits later in life

    Directory of Open Access Journals (Sweden)

    Slavka Kristan

    1997-01-01

    Full Text Available The project called Footsteps to the Book is being carried out at the youth department of the Library Miran Jarc in Novo mesto; in it, preschool children from the municipalities Novo mesto, Šentjernej and Škocjan participate. The child wins the reading badge - Iridescent Little Fish with a pin - by telling four stories (or poemsin the library that havebeen told or read to him by his parents. Family appreciation can be won by both parents and children. The project has been started with the intention of lessening the impact of media upon children, and of strengthening the spiritual bondage among parents and children through reading. The purpose of the above mentioned activity is to develop and enrich child's language and thinking and help h im form positive self esteem. Through family reading, we tried to attract to the library not only small children but also their parents and to get them accustomed to the regular use of library materials. The opinions of parents,librarians, teachers and educators are very encouraging and the cooperation of children is better each year.

  16. Scaling behavior of mixed-state hall effect in MgB2 thin films

    International Nuclear Information System (INIS)

    Jung, Soon-Gil; Seong, W.K.; Kang, W.N.; Choi, Eun-Mi; Kim, Heon-Jung; Lee, Sung-Ik; Kim, Hyeong-Jin; Kim, H.C.

    2006-01-01

    The Hall resistivity (ρ xy ) and the longitudinal resistivity (ρ xx ) in c-axis-oriented superconducting MgB 2 thin films have been investigated in extended fields up to 18T. We have observed a scaling behavior between the Hall resistivity and the longitudinal resistivity, ρ xy =Aρ xx β , where the exponent (β) is observed to be independent of the temperatures and the magnetic fields. For a wide magnetic field region from 1 to 18T and a wide temperature region from 10 to 28K, a universal power law with β=2.0+/-0.1 was observed in c-axis-oriented MgB 2 thin films. These results can be well interpreted by using recent models

  17. Occupational radiation exposure in the GDR in 1977

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1977, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,348 persons), measurements with a whole-body counter (198 persons) and analyses of biosamples (174 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 253. In 6 cases the monthly exposure exceeded 30 mGy and the 9 highest annual exposure values were in the range of 50 to 120 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual radiation exposure was below one-tenth the maximum permissible dose. (author)

  18. Mechanical, barrier and morphological properties of starch nanocrystals-reinforced pea starch films.

    Science.gov (United States)

    Li, Xiaojing; Qiu, Chao; Ji, Na; Sun, Cuixia; Xiong, Liu; Sun, Qingjie

    2015-05-05

    To characterize the pea starch films reinforced with waxy maize starch nanocrystals, the mechanical, water vapor barrier and morphological properties of the composite films were investigated. The addition of starch nanocrystals increased the tensile strength of the composite films, and the value of tensile strength of the composite films was highest when starch nanocrystals content was 5% (w/w). The moisture content (%), water vapor permeability, and water-vapor transmission rate of the composite films significantly decreased as starch nanocrystals content increased. When their starch nanocrystals content was 1-5%, the starch nanocrystals dispersed homogeneously in the composite films, resulting in a relatively smooth and compact film surface and better thermal stability. However, when starch nanocrystals content was more than 7%, the starch nanocrystals began to aggregate, which resulted in the surface of the composite films developing a longitudinal fibrous structure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Surface Plasmon Waves on Thin Metal Films.

    Science.gov (United States)

    Craig, Alan Ellsworth

    Surface-plasmon polaritons propagating on thin metal films bounded by dielectrics of nearly equal refractive indexes comprise two bound modes. Calculations indicate that, while the modes are degenerate on thick films, both the real and the imaginary components of the propagation constants for the modes split into two branches on successively thinner films. Considering these non-degenerate modes, the mode exhibiting a symmetric (antisymmetric) transverse profile of the longitudinally polarized electric field component, has propagation constant components both of which increase (decrease) with decreasing film thickness. Theoretical propagation constant eigenvalue (PCE) curves have been plotted which delineate this dependence of both propagation constant components on film thickness. By means of a retroreflecting, hemispherical glass coupler in an attenuated total reflection (ATR) configuration, light of wavelength 632.8 nm coupled to the modes of thin silver films deposited on polished glass substrates. Lorentzian lineshape dips in the plots of reflectance vs. angle of incidence indicate the presence of the plasmon modes. The real and imaginary components of the propagation constraints (i.e., the propagation constant and loss coefficient) were calculated from the angular positions and widths of the ATR resonances recorded. Films of several thicknesses were probed. Results which support the theoretically predicted curves were reported.

  20. Division of Radiological Protection progress report 1982-1988

    International Nuclear Information System (INIS)

    Gupta, B.L.; Bhat, R.M.; Narayan, G.R.

    1989-01-01

    This report describes the work of the Division of Radiological Protection during 2-88, for implementation of radiation safety in all institutions in the country using radiation sources for medical, industrial and research applications. It gives information about personnel monitoring using photographic film and TLD badges, neutron monitoring badges, dosimetric techniques developed, calibration facilities and maintenance of national standards for radiation and radioactivity, design and fabrication of special radiation protection instruments, development of coloured indicators for indentification of radiation sterilized medical products, advisory and licencing services, regulation and transport of radioactive materials, periodic protection survey, education and training related to radiation safety programmes. About 500 publications by the staff of this Division are listed. (author). 46 figs

  1. Reading Books and Watching Films as a Protective Factor against Suicidal Ideation

    OpenAIRE

    Kasahara-Kiritani, Mami; Hadlaczky, Gerg?; Westerlund, Michael; Carli, Vladimir; Wasserman, Camilla; Apter, Alan; Balazs, Judit; Bobes, Julio; Brunner, Romuald; McMahon, Elaine M.; Cosman, Doina; Farkas, Luca; Haring, Christian; Kaess, Michael; Kahn, Jean-Pierre

    2015-01-01

    Reading books and watching films were investigated as protective factors for serious suicidal ideation (SSI) in young people with low perceived social belonging. Cross-sectional and longitudinal (12-month) analyses were performed using data from a representative European sample of 3256 students from the “Saving and Empowering Young Lives in Europe” study. Low social belonging was associated to SSI. However, reading books and watching films moderated this association, especially for those with...

  2. Access control system in Hamaoka Nuclear Power Station

    International Nuclear Information System (INIS)

    Kaneda, Hisashi; Shimura, Shigetaka; Suzuki, Katsuhiko; Kitazawa, Toshiichi

    1983-01-01

    The new computerized system has introduced to improve function of radiation protection for those who enter the radiation control area, by dealing with measurement of radiation dose, check of personal qualification, resistration of working condition and statistical treatment of these data. This system uses combined TLD, ''TL BADGE'', as a radiation detection sensor, instead of conventional pocket dosimeter and film badge. TL BADGE reading instrument are installed at the entrance to the control area and at working areas. The data of radiation dose, personal qualification etc. read by the reading instrument are transmitted directly to the computer system, which compiles and transacts these data. This system is consisted of three minicomputers, double memory files, CRTs for effective data search and display and floppy disks as a medium for registration, etc. Thus the computer system improves its reliability and the maintenanceability of data, being capable of automatical transaction of a great amount of data quickly. This report describes: Concept of using computer system, System outline, Measurement of radiation dose and Operational functions. (author)

  3. Subtle Raman signals from nano-diamond and β-SiC thin films

    International Nuclear Information System (INIS)

    Kuntumalla, Mohan Kumar; Ojha, Harish; Srikanth, Vadali Venkata Satya Siva

    2013-01-01

    Micro Raman scattering experiments are carried out in pursuit of subtle but discernable signals from nano-diamond and β-SiC thin films. The thin films are synthesized using microwave plasma assisted chemical vapor deposition technique. Raman scattering experiments in conjunction with scanning electron microscopy and x-ray diffraction were carried out to extract microstructure and phase information of the above mentioned thin films. Certain subtle Raman signals have been identified in this work. In the case of nanodiamond thin films, Raman bands at ∼ 485 and ∼ 1220 cm −1 are identified. These bands have been assigned to the nanodiamond present in nanodiamond thin films. In the case of nano β-SiC thin films, optical phonons are identified using surface enhanced Raman scattering. - Highlights: ► Subtle Raman signals from nano-diamond and β-silicon carbide related thin films. ► Raman bands at ∼ 485 and ∼ 1220 cm −1 from nanodiamond thin films are identified. ► Longitudinal optical phonon from nano β-silicon carbide thin films is identified

  4. The order parameters of a spin-1 Ising film in a transverse field

    International Nuclear Information System (INIS)

    Saber, A.; Ainane, A.; Dujardin, F.; Saber, M.; Stebe, B.

    1998-08-01

    Using the effective field theory with a probability distribution technique that accounts for the self-spin correlation functions, the layer longitudinal magnetizations and quadrupolar moments of a spin-1 Ising film and their averages are examined. These quantities as functions of the temperature, the ratio of the surface exchange interactions to the bulk ones, the strength of the transverse field and the film thickness are calculated numerically and some interesting results are obtained. (author)

  5. Collective dose of egyptian atomic energy workers during the period 1991-1995

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A; Youssef, S K [Reactor Division, and Radiation Protect. Dept., Nuclear Reseach Center Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The collective dose to egyptian atomic energy authority workers during the period from 1991 - 1995 were statistically evaluated. The personnel dosimetry in use since 1957 for evaluating external exposure doses was mainly the Harwell blue badge and kodak radiation monitoring film for X and Gamma photons. The calibration sensitivity of the badge system was evaluated under the `AL` and/or `Pb/Sn alloy` filters. The results of calibration showed 15% errors in the predicted values for whole body effective doses. The statistical survey showed that the annual collective dose ranged between 0.83-1.54 man Sv. The annual limit of exposure presented 25-58% of the recommended annual limit by ICRP- 60 (1991). Details of the study will be considered in the text. 4 tabs.

  6. Recent radiological studies of high level natural radiation areas of Ramsar

    International Nuclear Information System (INIS)

    Shorabi, M.

    1993-01-01

    The potential environmental gamma exposures measured by survey meters range from 0.05 to 9 mR.h -1 for indoor and outdoor exposures; the potential exposure in houses range from 0.6 to 360 mGy.y -1 as measured by TLDs, film badges and survey meters; the potential doses determined by film badges range from 1.2 to 186 mSv.y -1 ; and radon levels measured range from 20 to 3700 Bq.m -3 with corresponding effective doses up to 98.5 mSv.y -1 . The mean radon levels in different regions are 615 Bq.m -3 in Talesh Mahalleh, 326 Bq.m -3 in Chaparsar, 258 Bq.m -3 in schools of Ramsar, 246 Bq.m -3 in Ramak, 111 Bq.m -3 in Ramsar city, 50 Bq.m -3 in Sadat Mahalleh and Katalom, 49 Bq.m -3 in Tonekabon and 27 Bq.m -3 in Talesh Mahalleh of Katalom and 90 Bq.m -3 in old and 50 Bq.m -3 in new Ramsar Hotels. 15 refs, 2 figs, 1 tab

  7. Levels of doses to radiological workers in Ethiopia: 1977-1988

    International Nuclear Information System (INIS)

    Bayou, Teshome.

    1991-01-01

    During the period 1977 to 1988, a total of 10,494 Eastman Kodak type 2 film badges and 19,236 Vinten lithium fluoride thermoluminescence dosimeters (TLDS) were delivered to medical workers in Ethiopia of which 5,135 (48.93%) film badges and 19,177 (99.69%) TLDS were evaluated. The annual average occupational doses to the workers were estimated to be of 1.44 and 4.51 man-Sv with corresponding collective dose equivalents to 0.29 and 4.51 man-Sv respectively. Comparisons of doses to similar workers in different countries were compiled from the literature. Based on the TLD results and the 1977 International Commission on Radiological Protection (ICRP) risk coefficients it is estimated that the occurrence of extra fatal and non-fatal cancer cases is in the order of 74 per million radiological workers per year. The hereditary defects expected are 18 and 36 cases in the next two and in all future generations respectively. During these periods, the number of institutions monitored rose from 35 to 88 while the workers monitored increased from 100 to 450

  8. Improvement of personal dosimetry - Digital pocket dosemeter

    International Nuclear Information System (INIS)

    Radalj, Z.; Cerovac, Z.; Cerovac, H.; Brumen, V.; Prlic, I.

    1996-01-01

    Physical dosimetric surveillance of professional groups working with various radiation sources is a regular procedure in Croatia, established almost 40 years ago. Data available point out that the majority of professionals under surveillance are those employed in medical facilities, most of them working with X-ray sources. Depending on the nature of professional activities, personnel occupationally exposed to radiation sources are obliged to wear either film badge, TLD or film+TLD badge. Unfortunately, due to the line of data processing, all standard dosemeters have the same disadvantage i.e. up to 40 days delay in dose reporting, regarding the time of actual exposure. The significance of such a delay raises in cases when radiation dose was received within the short time or when technical failure on the operating unit(s) is suspected. Bearing this in mind, the additional dosimetric monitoring becomes an imperative. Therefore, we decided to introduce a palette of digital pocket dosemeters, meant to be used in different workplaces in the radiation zone, each of them being adjusted to the specificities of a particular workplace

  9. Occupational radiation exposure in the GDR in 1978

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1978, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,980 persons), measurements with a whole-body counter (186 persons) and analyses of biosamples (144 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 427. In 13 cases the monthly exposure exceeded 30 mGy, 8 persons received annual doses in the range of 50 to 120 mGy, and the highest annual dose was above 250 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual internal radiation exposure was well below one-tenth the maximum permissible dose. (author)

  10. Investigation of coercivity for electroplated Fe-Ni thick films

    Science.gov (United States)

    Yanai, T.; Eguchi, K.; Koda, K.; Kaji, J.; Aramaki, H.; Takashima, K.; Nakano, M.; Fukunaga, H.

    2018-05-01

    We have already reported Fe-Ni firms with good soft magnetic properties prepared by using an electroplating method. In our previous studies, we prepared the Fe-Ni films from citric-acid-based baths (CA-baths) and ammonium-chloride-based ones (AC-baths), and confirmed that the coercivity for the AC-baths was lower than that for the CA-baths. In the present study, we investigated reasons for the lower coercivity for the AC-baths to further improve the soft magnetic properties. From an observation of magnetic domains of the Fe22Ni78 films, we found that Fe22Ni78 film for AC-bath had a magnetic anisotropy in the width direction, and also found that the coercivity in the width direction was lower than the longitudinal one for the AC-bath. As an annealing for a stress relaxation in the films reduced the difference in the coercivity, we considered that the anisotropy is attributed to the magneto-elastic effect.

  11. Personal monitoring for external sources of beta and low energy photon radiations

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged.

  12. Personal monitoring for external sources of beta and low energy photon radiations

    International Nuclear Information System (INIS)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged. (author)

  13. PLD growth of CoPd thin films and characterization of their magnetic properties by magneto optical Kerr effect

    Science.gov (United States)

    Sedrpooshan, Mehran; Ahmadvand, Hossein; Ranjbar, Mehdi; Salamati, Hadi

    2018-06-01

    CoPd alloy thin films with different thicknesses and Co/Pd ratios have been deposited on Si (100) substrate by pulsed laser deposition (PLD). The magnetic properties were investigated by using the magneto-optical Kerr effect (MOKE) in both longitudinal and polar geometries. The results show that the films with thickness in the range of 6-24 nm, deposited at a low substrate temperature of 200 °C, are mostly magnetized in the plane of film. Higher deposition temperature forces the magnetic easy axis to orient in the perpendicular direction of the films.

  14. Nanosphere lithography applied to magnetic thin films

    Science.gov (United States)

    Gleason, Russell

    Magnetic nanostructures have widespread applications in many areas of physics and engineering, and nanosphere lithography has recently emerged as promising tool for the fabrication of such nanostructures. The goal of this research is to explore the magnetic properties of a thin film of ferromagnetic material deposited onto a hexagonally close-packed monolayer array of polystyrene nanospheres, and how they differ from the magnetic properties of a typical flat thin film. The first portion of this research focuses on determining the optimum conditions for depositing a monolayer of nanospheres onto chemically pretreated silicon substrates (via drop-coating) and the subsequent characterization of the deposited nanosphere layer with scanning electron microscopy. Single layers of permalloy (Ni80Fe20) are then deposited on top of the nanosphere array via DC magnetron sputtering, resulting in a thin film array of magnetic nanocaps. The coercivities of the thin films are measured using a home-built magneto-optical Kerr effect (MOKE) system in longitudinal arrangement. MOKE measurements show that for a single layer of permalloy (Py), the coercivity of a thin film deposited onto an array of nanospheres increases compared to that of a flat thin film. In addition, the coercivity increases as the nanosphere size decreases for the same deposited layer. It is postulated that magnetic exchange decoupling between neighboring nanocaps suppresses the propagation of magnetic domain walls, and this pinning of the domain walls is thought to be the primary source of the increase in coercivity.

  15. Concentrations of bisphenol a, bisphenol a diglycidyl ether, and their derivatives in canned foods in Japanese markets.

    Science.gov (United States)

    Yonekubo, Jun; Hayakawa, Kazuichi; Sajiki, Junko

    2008-03-26

    Bisphenol A (BPA), bisphenol A diglycidyl ether (BADGE), and their derivatives in 38 canned foods sold in Japan were measured using high-performance liquid chromatography-mass spectrometry (LC-MS) and LC-tandem mass spectrometry (LC-MS/MS). BPA, BADGE, BADGE.2H 2O, BADGE.HCl.H2O, BADGE.HCl, and BADGE.2HCl were 0-235.4, 0-3.4, 0-247.2, 0.2-196.4, 0-3.0, and 0-25.7 ng/g, respectively, which did not exceed acceptable daily intake for BPA and specific migration limit for BADGEs. BADGE was degraded by 58, 100, 46, and 58% in water (pH 7), 0.01 N HCl (pH 2), 0.01 N NaCl (pH 6.8), and 0.01 N NaCl with acetic acid (pH 2.5), respectively, when it was allowed to stand at 120 degrees C for 30 min. The prominent derivatives formed were BADGE.2H 2O and BADGE.HCl.H2O, which was formed not only in BADGE with added HCl but also in that with NaCl. Acetic acid accelerated the formation of both BADGE.2H2O and BADGE.HCl.H2O in NaCl. No BPA was detected in any simulation samples started from BADGE. The results suggest that BPA and BADGE are independently leached into canned foods and that BADGE is easily changed to more stable compounds such as BADGE.2H2O and BADGE.HCl.H2O by sterilization.

  16. Effect of three-dimensional deformations on local heat transfer to a nonuniformly heated falling film of liquid

    International Nuclear Information System (INIS)

    Chinnov, E.A.; Kabov, O.A.

    2004-01-01

    The experimental study on the heat transfer by the water film heated vertical flow is studied within the Reynolds number values from 1 to 45. The chart of the liquid film flow modes is plotted and the heat exchange areas are separated. The data on the dependence of the temperature of the heater walls and local heat flux at the heater symmetry axis on the longitudinal coordinate are obtained. The local heat exchange coefficients are measured. The comparison of the experimental data with the numerical calculations for the smooth film is carried out. The effect of the jet flow formation on the heat transfer to the liquid film is analyzed [ru

  17. Scaling of anomalous hall effect in amorphous CoFeB Films with accompanying quantum correction

    KAUST Repository

    Zhang, Yan; Mi, Wenbo; Wang, Xiaocha; Guo, Zaibing

    2015-01-01

    Scaling of anomalous Hall effect in amorphous CoFeB films with thickness ranging from 2 to 160 nm have been investigated. We have found that the scaling relationship between longitudinal (ρxx) and anomalous Hall (ρAH) resistivity is distinctly

  18. Planar Hall effect and magnetic anisotropy in epitaxially strained chromium dioxide thin films

    NARCIS (Netherlands)

    Goennenwein, S.T.B.; Keizer, R.S.; Schink, S.W.; Van Dijk, I.; Klapwijk, T.M.; Miao, G.X.; Xiao, G.; Gupta, A.

    2007-01-01

    We have measured the in-plane anisotropic magnetoresistance of 100?nm thick CrO2 thin films at liquid He temperatures. In low magnetic fields H, both the longitudinal and the transverse (planar Hall) resistance show abrupt switches, which characteristically depend on the orientation of H. All the

  19. Trends of personal dosimetry at atomic power plants

    International Nuclear Information System (INIS)

    Yamamura, Seini

    1998-01-01

    The individual dosimetry at the atomic power station is sorted for monthly dosimetry, daily dosimetry and special job dosimetry in high dose circumstance. Film badge (passive dosimeter) can measure gamma dose, beta dose and neutron dose respectively lower than about 0.1 mSv. While workers are in the radiation controlled area, they have to wear the dosimeters and the individual dose is accumulated for every one month. Recently the Silicon semiconductors detecting beta ray and neutron have been developed. With microcircuit technology and these new sensors, new multiple function dosimeter of the card size had been put to practical use. The result of dose measurement obtained by the electronic dosimeter is consistent well with the measurement of usual film badge and new dosimeter can determine the dose as low as 0.01 mSv. The result is stored in the non-volatile memory in the electronic personal dosimeter and held for more than one year without the power supply. The function to read data directly from the memory improves the reliability of the data protection. The realization of the unified radiation control system that uses the electronic personal dosimeter for monthly dosimetry is expected. (J.P.N.)

  20. Occupational Exposure to Ionising Radiation in Greece (1994-1998)

    International Nuclear Information System (INIS)

    Kamenopoulou, V.; Drikos, G.; Dimitriou, P.

    2000-01-01

    This study was scheduled in order to analyse the individual annual dose information on classified workers in Greece, monitored and assessed by the central dosimetry service at the Greek Atomic Energy Commission for the years 1994-98. This service provides film badges to about 7500 workers all over the country on a monthly basis. Dose summaries were recorded and processed by the Dose Registry Information System, the database of which has been totally renewed since 1994. The statistical analysis provided refers to and deals with the mean annual dose, the collective dose, the distribution of the dose over the different specialities and the number of workers that have exceeded any of the established dose levels. Results concerning the annual dose summaries demonstrate a decrease in the collective and the mean individual dose to workers in the year 1995 and a slight but steady year-by-year increase thereafter during the period under consideration. This increasing tendency is discussed along with the increase in the ionising radiation applications, especially those in the medical sector, the change of the positioning of the film badge and the quality control measures provided by Greek law for radiation laboratories. (author)

  1. Effects of long-term radiation exposure on chromosomal aberrations in radiological technologists

    International Nuclear Information System (INIS)

    Kumagai, Etsuko; Onomichi, Mitsukazu; Tanaka, Ryuji; Kumagai, Takashi; Sawada, Shozo.

    1990-01-01

    Chromosomal aberrations in the lymphocytes of radiation technologists (RT) were analyzed by the trypsin G-banding method to study the late effects of long-term exposure to low doses of radiation. Structural aberrations were identified in 384 (2.5%) of 15442 cells analyzed from 53 RT as compared to 177 (1.6%) of 11136 cells from 36 healthy controls. Stable aberrations were the most frequent in both groups and were either translocations or deletions. Unstable aberrations were mainly acentric fragments in both groups. The frequency of translocations and acentric fragments was significantly higher in the RT than in the controls and was highest in the RT over 50 years. The highest frequency observed in the >50 age group was attributed to the unknown for cumulative dose prior to introduction of film badges. Frequency of chromosomal aberrations correlated with the estimated dose from the film badges and years of experience of each RT based on the equation y=0.22+0.37D+4.35D 2 , where y is overall frequency of chromosomal aberrations and D is the estimated radiation dose in Sv. (author)

  2. Quantitative measurement of piezoelectric coefficient of thin film using a scanning evanescent microwave microscope.

    Science.gov (United States)

    Zhao, Zhenli; Luo, Zhenlin; Liu, Chihui; Wu, Wenbin; Gao, Chen; Lu, Yalin

    2008-06-01

    This article describes a new approach to quantitatively measure the piezoelectric coefficients of thin films at the microscopic level using a scanning evanescent microwave microscope. This technique can resolve 10 pm deformation caused by the piezoelectric effect and has the advantages of high scanning speed, large scanning area, submicron spatial resolution, and a simultaneous accessibility to many other related properties. Results from the test measurements on the longitudinal piezoelectric coefficient of PZT thin film agree well with those from other techniques listed in literatures.

  3. Numerical studies of film formation in context of steel coating

    Science.gov (United States)

    Aniszewski, Wojciech; Zaleski, Stephane; Popinet, Stephane

    2017-11-01

    In this work, we present a detailed example of numerical study of film formation in the context of metal coating. Liquid metal is drawn from a reservoir onto a retracting solid sheet, forming a coating film characterized by phenomena such as longitudinal thickness variation (in 3D) or waves akin to that predicted by Kapitza and Kapitza (visible in two dimensions as well). While the industry standard configuration for Zinc coating is marked by coexistence of medium Capillary number (Ca = 0.03) and film Reynolds number above 1000, we present also parametric studies in order to establish more clearly to what degree does the numerical method influence film regimes obtained in the target configuration. The simulations have been performed using Basilisk, a grid-adapting, strongly optimized code derived from Gerris . Mesh adaptation allows for arbitrary precision in relevant regions such as the contact line or the meniscus, while a coarse grid is applied elsewhere. This adaptation strategy, as the results indicate, is the only realistic approach for numerical method to cover the wide range of necessary scales from the predicted film thickness (hundreds of microns) to the domain size (meters).

  4. Hall effect of K-doped superconducting thin films

    Energy Technology Data Exchange (ETDEWEB)

    Son, Eunseon; Lee, Nam Hoon; Kang, Won Nam [Dept. of physics, Sungkyunkwan University, Suwon (Korea, Republic of); Hwang, Tae Jong; Kim, Dong Ho [Dept. of physics, Yeungnam University, Gyeongsan(Korea, Republic of)

    2013-09-15

    We have studied Hall effect for potassium (K)-doped BaFe{sub 2}As{sub 2}superconducting thin films by analyzing the relation between the longitudinal resistivity (ρ{sub xy}) and the Hall resistivity (ρ{sub xy}). The thin films used in this study were fabricated on Al{sub O3} (000l) substrates by using an ex-situ pulsed laser deposition (PLD) technique under a high-vacuum condition of ∼10{sup -6} Torr. The samples showed the high superconducting transition temperatures (T{sub C}) of ∼40 K. The ρ{sub xx} and ρ{sub xy}the for K-doped BaFeAs{sub 2} thin films were measured by using a physical property measurement system (PPMS) with a temperature sweep (T-sweep) mode at an applied current density of 100 A/cm{sup 2} and at magnetic fields from 0 up to 9 T. We report the T-sweep results of the ρ{sub xx} and the ρ{sub xy} to investigate Hall scaling behavior on the basis of the relation of ρ{sub xy} = A(ρ{sub xy}){sup β}. The ρ{sub xx} values are 3.0 ± 0.2 in the c-axis-oriented K-doped BaFeAs{sub 2} thin films, whereas the thin films with various oriented-directions like a polycrystal showed slightly lower β than that of c-axis-oriented thin films. Interestingly, the β value is decreased with increasing magnetic fields.

  5. Hand book on the use of TLD badge based on CaSO4:Dy teflon TLD discs for individual monitoring

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Adtani, M.M.; Varadharajan, G.; Bakshi, A.K.; Srivastava, Kshama; Bihari, R.R.

    2002-10-01

    Individual monitoring is one of the most important aspects of a radiation protection programme. In India, an official and centralized personnel monitoring service to radiation workers started in 1952. With the indigenous development of a TLD badge system in 1975 at Bhabha Atomic Research Centre, decentralization of monitoring service was initiated. At present, about 40,000 radiation workers are monitored using this system through twelve TLD units located in different parts of the country, including a private accredited laboratory. Regulatory and other inspecting bodies have often asked outstation TLD units to produce a duly approved document on the procedures being practiced for the assessment of personal doses. A need for such a document has also been felt to ensure the uniformity in processing of dosemeters, recording and reporting of doses by different TLD units and to provide guidelines regarding the infrastructure requirement. This document in the form of a handbook has been prepared to cater to the above needs. The handbook is expected to provide necessary guidelines not only to the newcomers/ forthcoming units and the existing laboratories but also to help the regulators, inspectors and assessors. (author)

  6. Radiation protection for nurses

    Energy Technology Data Exchange (ETDEWEB)

    Mould, R F

    1978-01-01

    Various aspects of radiation protection relevant to nurses are presented. The different radioisotopes used in internal radiotherapy and scintiscanning techniques and any necessary precautions which should be observed when nursing these patients are described. General information is also given on nuclear and atomic terminology, the physical half-life of radioisotopes, radiation dose as a function of distance, shielding, film badges and the maximum permissible dose.

  7. Longitudinal detection of ferromagnetic resonance using x-ray transmission measurements

    International Nuclear Information System (INIS)

    Boero, G.; Rusponi, S.; Kavich, J.; Rizzini, A. Lodi; Piamonteze, C.; Nolting, F.; Tieg, C.; Thiele, J.-U.; Gambardella, P.

    2009-01-01

    We describe a setup for the x-ray detection of ferromagnetic resonance in the longitudinal geometry using element-specific transmission measurements. Thin magnetic film samples are placed in a static magnetic field collinear with the propagation direction of a polarized soft x-ray beam and driven to ferromagnetic resonance by a continuous wave microwave magnetic field perpendicular to it. The transmitted photon flux is measured both as a function of the x-ray photon energy and as a function of the applied static magnetic field. We report experiments performed on a 15 nm film of doped Permalloy (Ni 73 Fe 18 Gd 7 Co 2 ) at the L 3 /L 2 -edges of Fe, Co, and Ni. The achieved ferromagnetic resonance sensitivity is about 0.1 monolayers/√(Hz). The obtained results are interpreted in the framework of a conductivity tensor based formalism. The factors limiting the sensitivity as well as different approaches for the x-ray detection of ferromagnetic resonance are discussed.

  8. Magnetic properties of epitaxial MnAs thin films on GaAs (001)

    CERN Document Server

    Park, Y S

    2000-01-01

    The magnetic properties of two types of epitaxial MnAs films on GaAs (001) substrates in the thickness range of 20 approx 200 nm were studied. Using longitudinal a magneto-optical Kerr-effect(MOKE) apparatus at lambda=632.8 nm, we determined the Curie temperatures of the 100-nm thick films to be 54.0+-0.5 .deg. C and 63.7+-0.5 .deg. C for type A films and type B films, respectively. The observed Curie temperatures corresponded to increases of 36.8 .deg. C and 33.9 .deg. C per one percent increase in the unit cell volume for type A and B, respectively. The normalized maximum MOKE signal from the type A film exhibited a first-order-like magnetic transition while that of type B underwent a second-order-like transition. These different behaviors between types A and B stem from different residual stresses being exerted on the hexagonal phase. Utilizing a Foner-type vibrating sample magnetometer at room temperature, we examined the thickness dependence of the coercive force and the saturation magnetization of the f...

  9. Thickness dependence of the quantum Hall effect in films of the three-dimensional Dirac semimetal Cd3As2

    Directory of Open Access Journals (Sweden)

    Manik Goyal

    2018-02-01

    Full Text Available Low-temperature magnetotransport studies are reported for (112Cd3As2 films grown on (111CdTe by molecular beam epitaxy as a function of the Cd3As2 film thickness. All films show Shubnikov-de Haas oscillations. An even-integer quantum Hall effect is observed for films thinner than 70 nm. For the thinnest films, the bulk is gapped and transport at low temperatures occurs only via the gapless, two-dimensional states. The lowest Landau level is reached at ∼10 T, and the longitudinal resistance nearly vanishes at the plateaus in the Hall resistance. The results are discussed in the context of the current theoretical understanding of topological surface states in three-dimensional Dirac semimetals.

  10. Characterization of the effective electrostriction coefficients in ferroelectric thin films

    Science.gov (United States)

    Kholkin, A. L.; Akdogan, E. K.; Safari, A.; Chauvy, P.-F.; Setter, N.

    2001-06-01

    Electromechanical properties of a number of ferroelectric films including PbZrxTi1-xO3(PZT), 0.9PbMg1/3Nb2/3O3-0.1PbTiO3(PMN-PT), and SrBi2Ta2O9(SBT) are investigated using laser interferometry combined with conventional dielectric measurements. Effective electrostriction coefficients of the films, Qeff, are determined using a linearized electrostriction equation that couples longitudinal piezoelectric coefficient, d33, with the polarization and dielectric constant. It is shown that, in PZT films, electrostriction coefficients slightly increase with applied electric field, reflecting the weak contribution of non-180° domains to piezoelectric properties. In contrast, in PMN-PT and SBT films electrostriction coefficients are field independent, indicating the intrinsic nature of the piezoelectric response. The experimental values of Qeff are significantly smaller than those of corresponding bulk materials due to substrate clamping and possible size effects. Electrostriction coefficients of PZT layers are shown to depend strongly on the composition and preferred orientation of the grains. In particular, Qeff of (100) textured rhombohedral films (x=0.7) is significantly greater than that of (111) layers. Thus large anisotropy of the electrostrictive coefficients is responsible for recently observed large piezoelectric coefficients of (100) textured PZT films. Effective electrostriction coefficients obtained by laser interferometry allow evaluation of the electromechanical properties of ferroelectric films based solely on the dielectric parameters and thus are very useful in the design and fabrication of microsensors and microactuators.

  11. Low temperature aluminum nitride thin films for sensory applications

    Energy Technology Data Exchange (ETDEWEB)

    Yarar, E.; Zamponi, C.; Piorra, A.; Quandt, E., E-mail: eq@tf.uni-kiel.de [Institute for Materials Science, Chair for Inorganic Functional Materials, Kiel University, D-24143 Kiel (Germany); Hrkac, V.; Kienle, L. [Institute for Materials Science, Chair for Synthesis and Real Structure, Kiel University, D-24143 Kiel (Germany)

    2016-07-15

    A low-temperature sputter deposition process for the synthesis of aluminum nitride (AlN) thin films that is attractive for applications with a limited temperature budget is presented. Influence of the reactive gas concentration, plasma treatment of the nucleation surface and film thickness on the microstructural, piezoelectric and dielectric properties of AlN is investigated. An improved crystal quality with respect to the increased film thickness was observed; where full width at half maximum (FWHM) of the AlN films decreased from 2.88 ± 0.16° down to 1.25 ± 0.07° and the effective longitudinal piezoelectric coefficient (d{sub 33,f}) increased from 2.30 ± 0.32 pm/V up to 5.57 ± 0.34 pm/V for film thicknesses in the range of 30 nm to 2 μm. Dielectric loss angle (tan δ) decreased from 0.626% ± 0.005% to 0.025% ± 0.011% for the same thickness range. The average relative permittivity (ε{sub r}) was calculated as 10.4 ± 0.05. An almost constant transversal piezoelectric coefficient (|e{sub 31,f}|) of 1.39 ± 0.01 C/m{sup 2} was measured for samples in the range of 0.5 μm to 2 μm. Transmission electron microscopy (TEM) investigations performed on thin (100 nm) and thick (1.6 μm) films revealed an (002) oriented AlN nucleation and growth starting directly from the AlN-Pt interface independent of the film thickness and exhibit comparable quality with the state-of-the-art AlN thin films sputtered at much higher substrate temperatures.

  12. Wafer-scale growth of highly textured piezoelectric thin films by pulsed laser deposition for micro-scale sensors and actuators

    Science.gov (United States)

    Nguyen, M. D.; Tiggelaar, R.; Aukes, T.; Rijnders, G.; Roelof, G.

    2017-11-01

    Piezoelectric lead-zirconate-titanate (PZT) thin films were deposited on 4-inch (111)Pt/Ti/SiO2/Si(001) wafers using large-area pulsed laser deposition (PLD). This study was focused on the homogeneity in film thickness, microstructure, ferroelectric and piezoelectric properties of PZT thin films. The results indicated that the highly textured (001)-oriented PZT thin films with wafer-scale thickness homogeneity (990 nm ± 0.8%) were obtained. The films were fabricated into piezoelectric cantilevers through a MEMS microfabrication process. The measured longitudinal piezoelectric coefficient (d 33f = 210 pm/V ± 1.6%) and piezoelectric transverse coefficient (e 31f = -18.8 C/m2 ± 2.8%) were high and homogeneity across wafers. The high piezoelectric properties on Si wafers will extend industrial application of PZT thin films and further development of piezoMEMS.

  13. Occupational exposure at the Department of Nuclear Medicine as a work environment: A 19-year follow-up

    OpenAIRE

    Piwowarska-Bilska, Hanna; Birkenfeld, Bożena; Gwardyś, Aleksandra; Supińska, Aleksandra; Listewnik, Maria H.; Elbl, Bogumiła; Cichoń-Bańkowska, Katarzyna

    2011-01-01

    Summary Background: This study assessed the radiation safety at Nuclear Medicine Department being a work environment. Ionizing radiation exposure of the employees in the last 19 years and the effects of legislative changes in radiological protection were analyzed. Material/Methods: All employees of the investigated department were regularly and individually monitored using chest badges equipped with Kodak film type 2. Overall, 629 annual doses of the employees of nuclear medicine department, ...

  14. Comparative evaluations of individual radiation doses at hospital environment in two decades 73-82 and 86-95

    International Nuclear Information System (INIS)

    Carreira, Mauricio Costa; Almeida, Adelaide de; Santos, Maria Concepta P.S.

    1996-01-01

    Individual radiation doses in two decades of Hospital das Clinicas, Ribeirao Preto, Sao Paulo State, Brazil, are analysed. The annual values are studied according to the hospital service and specific worker categories. The workers are classified in categories A or B as recommended by ICRP 35. Three types of individual monitors (film badges, Ca So 4 and Li F + Ca So 4 ) supplied by three distinct laboratories are compared

  15. Elastic properties of porous low-k dielectric nano-films

    Science.gov (United States)

    Zhou, W.; Bailey, S.; Sooryakumar, R.; King, S.; Xu, G.; Mays, E.; Ege, C.; Bielefeld, J.

    2011-08-01

    Low-k dielectrics have predominantly replaced silicon dioxide as the interlayer dielectric for interconnects in state of the art integrated circuits. In order to further reduce interconnect RC delays, additional reductions in k for these low-k materials are being pursued via the introduction of controlled levels of porosity. The main challenge for such dielectrics is the substantial reduction in elastic properties that accompanies the increased pore volume. We report on Brillouin light scattering measurements used to determine the elastic properties of these films at thicknesses well below 200 nm, which are pertinent to their introduction into present ultralarge scale integrated technology. The observation of longitudinal and transverse standing wave acoustic resonances and their transformation into traveling waves with finite in-plane wave vectors provides for a direct non-destructive measure of the principal elastic constants that characterize the elastic properties of these porous nano-scale films. The mode dispersion further confirms that for porosity levels of up to 25%, the reduction in the dielectric constant does not result in severe degradation in the Young's modulus and Poisson's ratio of the films.

  16. Applied longitudinal analysis

    CERN Document Server

    Fitzmaurice, Garrett M; Ware, James H

    2012-01-01

    Praise for the First Edition "". . . [this book] should be on the shelf of everyone interested in . . . longitudinal data analysis.""-Journal of the American Statistical Association   Features newly developed topics and applications of the analysis of longitudinal data Applied Longitudinal Analysis, Second Edition presents modern methods for analyzing data from longitudinal studies and now features the latest state-of-the-art techniques. The book emphasizes practical, rather than theoretical, aspects of methods for the analysis of diverse types of lo

  17. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  18. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  19. Strain transfer through film-substrate interface and surface curvature evolution during a tensile test

    Science.gov (United States)

    He, Wei; Han, Meidong; Goudeau, Philippe; Bourhis, Eric Le; Renault, Pierre-Olivier; Wang, Shibin; Li, Lin-an

    2018-03-01

    Uniaxial tensile tests on polyimide-supported thin metal films are performed to respectively study the macroscopic strain transfer through an interface and the surface curvature evolution. With a dual digital image correlation (DIC) system, the strains of the film and the substrate can be simultaneously measured in situ during the tensile test. For the true strains below 2% (far beyond the films' elastic limit), a complete longitudinal strain transfer is present irrespective of the film thickness, residual stresses and microstructure. By means of an optical surface profiler, the three-dimensional (3D) topography of film surface can be obtained during straining. As expected, the profile of the specimen center remains almost flat in the tensile direction. Nevertheless, a relatively significant curvature evolution (of the same order with the initial curvature induced by residual stresses) is observed along the transverse direction as a result of a Poisson's ratio mismatch between the film and the substrate. Furthermore, finite element method (FEM) has been performed to simulate the curvature evolution considering the geometric nonlinearity and the perfect strain transfer at the interface, which agrees well with the experimental results.

  20. Reproducibility Test for Thermoluminescence Dosimeter (TLD) Using TLD Radpro

    International Nuclear Information System (INIS)

    Nur Khairunisa Zahidi; Ahmad Bazlie Abdul Kadir; Faizal Azrin Abdul Razalim

    2016-01-01

    Thermoluminescence dosimeters (TLD) as one type of dosimeter which are often used to substitute the film badge. Like a film badge, it is worn for a period of time and then must be processed to determine the dose received. This study was to test the reproducibility of TLD using Radpro reader. This study aimed to determine the dose obtained by TLD-100 chips when irradiated with Co-60 gamma source and to test the effectiveness of TLD Radpro reader as a machine to analyse the TLD. Ten chips of TLD -100 were irradiated using Eldorado machine with Co-60 source at a distance of 5 meters from the source with 2 mSv dose exposure. After the irradiation process, TLD-100 chips were read using the TLD Radpro reader. These steps will be repeated for nine times to obtain reproducibility coefficient, r i . The readings of dose obtained from experiment was almost equivalent to the actual dose. Results shows that the average value obtained for reproducibility coefficient, r i is 6.39 % which is less than 10 %. As conclusion, the dose obtained from experiment considered accurate because its value were almost equivalent to the actual dose and TLD Radpro was verified as a good reader to analyse the TLD. (author)

  1. Individual dosimetry in planned, existing and accidental exposure situations

    International Nuclear Information System (INIS)

    Gomaa, M.A.M; El Deen, T.S.; Morsy, T.; Shabon, M.H.

    2010-01-01

    There are three types of radiation exposure which include Planned exposure situations, Existing exposure situations and Emergency exposure situations which are defined as Situations that may occur during the operation of a planned situation, or from a malicious act, or from any other unexpected situation, and require urgent action in order to avoid or reduce undesirable consequences. A given individual may be exposed as a worker, and/or as a member of the public, and/or as a patient. Workers in medical professions involving radiation are occupationally exposed. For individual monitoring of exposed workers, Film badges or thermo luminescence dosimeters are in use. In cases where individual may be suspected to be contaminated internally, contamination monitors are used to monitor the site and whole body counters to monitor individuals. Members of the public are exposure to cosmic rays during air flights. Film badges were used to exposure of workers to NORM during maintenance work in old oil field. TLD is used for exposure workers in nuclear medicine department. Any radiation accident will add knowledge and experience. Accidents from lost, stolen or neglected sources are particularly special because the radiation exposure patterns of the individuals involved and the scenario of the accident are always different

  2. Reading Books and Watching Films as a Protective Factor against Suicidal Ideation.

    Science.gov (United States)

    Kasahara-Kiritani, Mami; Hadlaczky, Gergö; Westerlund, Michael; Carli, Vladimir; Wasserman, Camilla; Apter, Alan; Balazs, Judit; Bobes, Julio; Brunner, Romuald; McMahon, Elaine M; Cosman, Doina; Farkas, Luca; Haring, Christian; Kaess, Michael; Kahn, Jean-Pierre; Keeley, Helen; Nemes, Bogdan; Mars Bitenc, Urša; Postuvan, Vita; Saiz, Pilar; Sisask, Merike; Värnik, Airi; Sarchiapone, Marco; Hoven, Christina W; Wasserman, Danuta

    2015-12-15

    Reading books and watching films were investigated as protective factors for serious suicidal ideation (SSI) in young people with low perceived social belonging. Cross-sectional and longitudinal (12-month) analyses were performed using data from a representative European sample of 3256 students from the "Saving and Empowering Young Lives in Europe" study. Low social belonging was associated to SSI. However, reading books and watching films moderated this association, especially for those with lowest levels of belonging. This was true both at baseline and at 12 months of follow-up analyses. These media may act as sources of social support or mental health literacy and thus reduce the suicide risk constituted by low sense of belonging.

  3. Reading Books and Watching Films as a Protective Factor against Suicidal Ideation

    Directory of Open Access Journals (Sweden)

    Mami Kasahara-Kiritani

    2015-12-01

    Full Text Available Reading books and watching films were investigated as protective factors for serious suicidal ideation (SSI in young people with low perceived social belonging. Cross-sectional and longitudinal (12-month analyses were performed using data from a representative European sample of 3256 students from the “Saving and Empowering Young Lives in Europe” study. Low social belonging was associated to SSI. However, reading books and watching films moderated this association, especially for those with lowest levels of belonging. This was true both at baseline and at 12 months of follow-up analyses. These media may act as sources of social support or mental health literacy and thus reduce the suicide risk constituted by low sense of belonging.

  4. Strongly Enhanced Piezoelectric Response in Lead Zirconate Titanate Films with Vertically Aligned Columnar Grains

    Science.gov (United States)

    2017-01-01

    Pb(Zr0.52Ti0.48)O3 (PZT) films with (001) orientation were deposited on Pt(111)/Ti/SiO2/Si(100) substrates using pulsed laser deposition. Variation of the laser pulse rate during the deposition of the PZT films was found to play a key role in the control of the microstructure and to change strongly the piezoelectric response of the thin film. The film deposited at low pulse rate has a denser columnar microstructure, which improves the transverse piezoelectric coefficient (d31f) and ferroelectric remanent polarization (Pr), whereas the less densely packed columnar grains in the film deposited at high pulse rates give rise to a significantly higher longitudinal piezoelectric coefficient (d33f) value. The effect of film thickness on the ferroelectric and piezoelectric properties of the PZT films was also investigated. With increasing film thickness, the grain column diameter gradually increases, and also the average Pr and d33f values become larger. The largest piezoelectric coefficient of d33f = 408 pm V–1 was found for a 4-μm film thickness. From a series of films in the thickness range 0.5–5 μm, the z-position dependence of the piezoelectric coefficient could be deduced. A local maximum value of 600 pm V–1 was deduced in the 3.5–4.5 μm section of the thickest films. The dependence of the film properties on film thickness is attributed to the decreasing effect of the clamping constraint imposed by the substrate and the increasing spatial separation between the grains with increasing film thickness. PMID:28247756

  5. Danger - guard against radiation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1978-01-01

    Part 2 of this article for nurses on hazards and precautions in the use of radiation in medicine gives a brief account of the technique of afterloading, problems in the use of radioisotopes, such as 131 I, in liquid form, dose rates from commonly used isotopes, and precautions to be observed, including the use of shielding and film badges and monitors. Maximum permissible doses and a nuclear terminology chart are included. (author)

  6. Danger - guard against radiation. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Mould, R F [Westminster Hospital, London (UK)

    1978-09-07

    Part 2 of this article for nurses on hazards and precautions in the use of radiation in medicine gives a brief account of the technique of afterloading, problems in the use of radioisotopes, such as /sup 131/I, in liquid form, dose rates from commonly used isotopes, and precautions to be observed, including the use of shielding and film badges and monitors. Maximum permissible doses and a nuclear terminology chart are included.

  7. Annealing effect on optical properties of ZnO films fabricated by cathodic electrodeposition

    International Nuclear Information System (INIS)

    Wang Qingtao; Wang Guanzhong; Jie Jiansheng; Han Xinhai; Xu Bo; Hou, J.G.

    2005-01-01

    (001)-oriented ZnO films on Zn substrates were synthesized by cathodic electrodeposition from an aqueous solution composed only of 0.05 M zinc nitrate at 65 deg. C. A bound exciton emission band around 3.34 eV along with three longitudinal optical (LO) phonon replicas and an intensive broad emission band around 2.17 eV were observed from the photoluminescence (PL) spectra of ZnO films prepared at more positive potential (- 0.6∼- 0.8 V). When more negative potential (- 1.0∼- 1.4 V) was applied, the ultraviolet emission band disappeared. These results indicate that more positive electrodeposition potential favors the high quality ZnO film growth. The PL spectra of the annealed ZnO films prepared at more positive electrodeposition potentials - 0.6∼- 1.0 V exhibit the ultraviolet emission at 3.35 eV and a negligibly weak emission from defects. Annealing resulted in the enhancement and sharpening of the excitonic emission band and decrease of the deep level emission. The bandgap (E g ) of the ZnO film prepared at - 1.0 V on indium tin oxide (ITO) substrate decreased from 3.56 to 3.29 eV due to the removing of Zn(OH) 2 from the film after annealing

  8. Restoration of longitudinal images.

    Science.gov (United States)

    Hu, Y; Frieden, B R

    1988-01-15

    In this paper, a method of restoring longitudinal images is developed. By using the transfer function for longitudinal objects, and inverse filtering, a longitudinal image may be restored. The Fourier theory and sampling theorems for transverse images cannot be used directly in the longitudinal case. A modification and reasonable approximation are introduced. We have numerically established a necessary relationship between just-resolved longitudinal separation (after inverse filtering), noise level, and the taking conditions of object distance and lens diameter. An empirical formula is also found to well-fit the computed results. This formula may be of use for designing optical systems which are to image longitudinal details, such as in robotics or microscopy.

  9. On the origin of the changes in the opto-electrical properties of boron-doped zinc oxide films after plasma surface treatment for thin-film silicon solar cell applications

    Science.gov (United States)

    Le, Anh Huy Tuan; Kim, Youngkuk; Lee, Youn-Jung; Hussain, Shahzada Qamar; Nguyen, Cam Phu Thi; Lee, Jaehyung; Yi, Junsin

    2018-03-01

    The modification of the steep and sharp valleys on the surface of the boron-doped zinc oxide (BZO) front electrodes by plasma surface treatment is a critical process for avoiding a significant reduction in the electrical performance of thin-film silicon solar cells. In this work, we report the origin of the changes in the electrical and optical properties of the BZO films that occur after this process. On the basis of an analysis of the chemical states, we found an improvement of the carrier concentration along with the treatment time that was mainly due to an increase of the oxygen vacancy. This indicated a deficiency of the oxygen in the BZO films under argon-ion bombardment. The red-shift of the A1 longitudinal optical mode frequency in the Raman spectra that was attributed to the existence of vacancy point defects within the films also strengthened this argument. The significant reduction of the haze ratio as well as the appearance of interference peaks on the transmittance spectra as the treatment time was increased were mainly due to the smoothing of the film surface, which indicated a degradation of the light-scattering capability of the BZO films. We also observed a gain of the visible-region transmittance that was attributed to the decrease of the thickness of the BZO films after the plasma surface treatment, instead of the crystallinity improvement. On the basis of our findings, we have proposed a further design rule of the BZO front electrodes for thin-film silicon solar cell applications.

  10. Scaling of the anomalous Hall current in Fe100−x(SiO2)x films

    KAUST Repository

    Xu, W. J.; Zhang, Bei; Wang, Q. X.; Mi, W. B.; Wang, Z.; Li, W.; Yu, R. H.; Zhang, Xixiang

    2011-01-01

    To study the origin of the anomalous Hall effect, Fe100−x(SiO2)x granular films with a volume fraction of SiO2 (0 ⩽ x ⩽ 40.51) were fabricated using cosputtering. Hall and longitudinal resistivities were measured in the temperature range of 5–350 K

  11. Temperature-dependent polarized luminescence of exciton polaritons in a ZnO film

    Energy Technology Data Exchange (ETDEWEB)

    Toropov, A.A.; Nekrutkina, O.V.; Shubina, T.V. [Ioffe Physico-Technical Institute, Russian Academy of Sciences, St. Petersburg 194021 (Russian Federation); Gruber, Th.; Kirchner, C. [Department of Semiconductor Physics, Ulm University, 89081 Ulm (Germany); Waag, A. [Institute of Semiconductor Technology, Braunschweig Technical University, 38106 Braunschweig (Germany); Karlsson, K.F.; Monemar, B. [Linkoeping University, 581 83 Linkoeping (Sweden)

    2005-02-01

    We report on the studies of linearly polarized photoluminescence (PL) in a (0001) oriented ZnO epitaxial film, grown by metal organic chemical vapor deposition on a GaN template. The emission of mixed longitudinal-transverse exciton polariton modes was observed up to 130 K that evidences polaritonic nature of the excitonic spectrum up to this elevated temperature. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  12. Angular dependencies of longitudinal magnetoresistivity and planar Hall effect of single and multilayered thin films

    International Nuclear Information System (INIS)

    Ko, T.W.; Lee, J.H.; Park, B.K.; Rhie, K.; Jang, P.W.; Hwang, D.G.; Lee, S.S.; Kim, M.Y.; Rhee, J.R.

    1998-01-01

    Magnetoresistivity and planar Hall effect of a Glass/Fe70A/[Co21A/Cu25A] 20 multilayer coupled antiferromagnetically a single layer (Co81Nb19) thin film, and NiO based Glass/Ni350A/Py50A/Cu20A/Py50A (Py = Ni 83 Fe 17 ) spin value are studied. Planar Hall resistivity is analysed concurrently with the resistivity of the sample. With variation of direction and strength of the applied fields, we found that the magnetization process affects significantly the planar Hall effect. We developed a simple method to find the easy axis of single layer magnetic thin films. We also observed the variation of magnetization of each layer separately for an antiferromagnetically coupled multilayer, and a NiO-based spin value with the planar Hall effect. (author)

  13. The longitudinal sagittal growth changes of maxilla and mandible according to quantitative cervical vertebral maturation.

    Science.gov (United States)

    Chen, Lili; Lin, Jiuxiang; Xu, Tianmin; Long, Xiaosi

    2009-04-01

    To investigate the longitudinal sagittal growth changes of maxilla and mandible according to the quantitative cervical vertebral maturation (QCVM) for adolescents with normal occlusion, mixed longitudinal data were used. The samples included 87 adolescents aged from 8 to 18 y old with normal occlusion (32 males, 55 females) selected from 901 candidates. Sequential lateral cephalograms and hand-wrist films were taken once a year, lasting for 6 y. The longitudinal sagittal growth changes of maxilla and mandible according to QCVM were measured. There were some significant differences between maxilla and mandible according to QCVM. The sagittal growth change of maxilla showed a trend towards high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. The sagittal growth change of mandible showed a trend towards accelerating velocity-->high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. With sagittal relationship, growth magnitude was almost the same between maxilla and mandible at QCVM stage I. At stage II the growth of mandible exceeded that of maxilla and growth in mandible continued at stages III and IV, while the maxilla ceased to grow. Growth magnitude was greater and the growth duration was longer with male mandible. It is concluded that the longitudinal sagittal growth changes of maxilla and mandible on the basis of QCVM is of value in the orthodontic practice.

  14. Anomalous Hall effect scaling in ferromagnetic thin films

    KAUST Repository

    Grigoryan, Vahram L.

    2017-10-23

    We propose a scaling law for anomalous Hall effect in ferromagnetic thin films. Our approach distinguishes multiple scattering sources, namely, bulk impurity, phonon for Hall resistivity, and most importantly the rough surface contribution to longitudinal resistivity. In stark contrast to earlier laws that rely on temperature- and thickness-dependent fitting coefficients, this scaling law fits the recent experimental data excellently with constant parameters that are independent of temperature and film thickness, strongly indicating that this law captures the underlying physical processes. Based on a few data points, this scaling law can even fit all experimental data in full temperature and thickness range. We apply this law to interpret the experimental data for Fe, Co, and Ni and conclude that (i) the phonon-induced skew scattering is unimportant as expected; (ii) contribution from the impurity-induced skew scattering is negative; (iii) the intrinsic (extrinsic) mechanism dominates in Fe (Co), and both the extrinsic and intrinsic contributions are important in Ni.

  15. Anomalous Hall effect scaling in ferromagnetic thin films

    KAUST Repository

    Grigoryan, Vahram L.; Xiao, Jiang; Wang, Xuhui; Xia, Ke

    2017-01-01

    We propose a scaling law for anomalous Hall effect in ferromagnetic thin films. Our approach distinguishes multiple scattering sources, namely, bulk impurity, phonon for Hall resistivity, and most importantly the rough surface contribution to longitudinal resistivity. In stark contrast to earlier laws that rely on temperature- and thickness-dependent fitting coefficients, this scaling law fits the recent experimental data excellently with constant parameters that are independent of temperature and film thickness, strongly indicating that this law captures the underlying physical processes. Based on a few data points, this scaling law can even fit all experimental data in full temperature and thickness range. We apply this law to interpret the experimental data for Fe, Co, and Ni and conclude that (i) the phonon-induced skew scattering is unimportant as expected; (ii) contribution from the impurity-induced skew scattering is negative; (iii) the intrinsic (extrinsic) mechanism dominates in Fe (Co), and both the extrinsic and intrinsic contributions are important in Ni.

  16. Dimensional scaling of perovskite ferroelectric thin films

    Science.gov (United States)

    Keech, Ryan R.

    Dimensional size reduction has been the cornerstone of the exponential improvement in silicon based logic devices for decades. However, fundamental limits in the device physics were reached ˜2003, halting further reductions in clock speed without significant penalties in power consumption. This has motivated the research into next generation transistors and switching devices to reinstate the scaling laws for clock speed. This dissertation aims to support the scaling of devices that are based on ferroelectricity and piezoelectricity and to provide a roadmap for the corresponding materials performance. First, a scalable growth process to obtain highly {001}-oriented lead magnesium niobate - lead titanate (PMN-PT) thin films was developed, motivated by the high piezoelectric responses observed in bulk single crystals. It was found that deposition of a 2-3 nm thick PbO buffer layer on {111} Pt thin film bottom electrodes, prior to chemical solution deposition of PMN-PT reduces the driving force for Pb diffusion from the PMN-PT to the bottom electrode, and facilitates nucleation of {001}-oriented perovskite grains. Energy dispersive spectroscopy demonstrated that up to 10% of the Pb from a PMN-PT precursor solution may diffuse into the bottom electrode. PMN-PT grains with a mixed {101}/{111} orientation in a matrix of Pb-deficient pyrochlore phase were then promoted near the interface. When this is prevented, phase pure films with {001} orientation with Lotgering factors of 0.98-1.0, can be achieved. The resulting films of only 300 nm in thickness exhibit longitudinal effective d33,f coefficients of ˜90 pm/V and strain values of ˜1% prior to breakdown. 300 nm thick epitaxial and polycrystalline lead magnesium niobate - lead titanate (70PMN-30PT) blanket thin films were studied for the relative contributions to property thickness dependence from interfacial and grain boundary low permittivity layers. Epitaxial PMN-PT films were grown on SrRuO 3 /(001)SrTiO3, while

  17. SU-E-T-155: Calibration of Variable Longitudinal Strength 103Pd Brachytherapy Sources

    International Nuclear Information System (INIS)

    Reed, J; Radtke, J; Micka, J; Culberson, W; DeWerd, L

    2015-01-01

    Purpose: Brachytherapy sources with variable longitudinal strength (VLS) allow for a customized intensity along the length of the source. These have applications in focal brachytherapy treatments of prostate cancer where dose boosting can be achieved through modulation of intra-source strengths. This work focused on development of a calibration methodology for VLS sources based on measurements and Monte Carlo (MC) simulations of five 1 cm 10 3 Pd sources each containing four regions of variable 103 Pd strength. Methods: The air-kerma strengths of the sources were measured with a variable-aperture free-air chamber (VAFAC). Source strengths were also measured using a well chamber. The in-air azimuthal and polar anisotropy of the sources were measured by rotating them in front of a NaI scintillation detector and were calculated with MC simulations. Azimuthal anisotropy results were normalized to their mean intensity values. Polar anisotropy results were normalized to their average transverse axis intensity values. The relative longitudinal strengths of the sources were measured via on-contact irradiations with radiochromic film, and were calculated with MC simulations. Results: The variable 103 Pd loading of the sources was validated by VAFAC and well chamber measurements. Ratios of VAFAC air-kerma strengths and well chamber responses were within ±1.3% for all sources. Azimuthal anisotropy results indicated that ≥95% of the normalized values for all sources were within ±1.7% of the mean values. Polar anisotropy results indicated variations within ±0.3% for a ±7.6° angular region with respect to the source transverse axis. Locations and intensities of the 103 Pd regions were validated by radiochromic film measurements and MC simulations. Conclusion: The calibration methodology developed in this work confirms that the VLS sources investigated have a high level of polar uniformity, and that the strength and longitudinal intensity can be verified experimentally and

  18. Dependence of atomic oxygen resistance and the tribological properties on microstructures of WS2 films

    International Nuclear Information System (INIS)

    Xu, Shusheng; Gao, Xiaoming; Hu, Ming; Sun, Jiayi; Jiang, Dong; Wang, Desheng; Zhou, Feng; Weng, Lijun; Liu, Weimin

    2014-01-01

    Graphical abstract: - Highlights: • Pure WS 2 and WS 2 -Al composite films with different structures were prepared. • The compactness of WS 2 film was significantly improved due to incorporation of Al. • Different mechanisms of atomic oxygen resistance of both the films were discussed. • Films before and after AO irradiation kept the unchanged tribological properties. • The composite films showed much better wear resistance than pure WS 2 film. - Abstract: To study the anti-oxidation mechanism of WS 2 films, the pure WS 2 , and Al doped WS 2 composite films were prepared via radio frequency sputtering and the atomic oxygen (AO) irradiation tests were conducted using a ground AO simulation facility. The tribological properties of both films before and after AO irradiation were evaluated using vacuum ball-on-disk tribo-tester. The incorporation of a small fraction of Al dopant resulted in microstructure change from loose columnar platelet with significant porosity for pure WS 2 film to very dense structure. In pure WS 2 film, WS 2 exists as crystalline phase with edge-plane preferential orientation, but nanocrystalline and amorphous phase coexists for the WS 2 -Al composite film. Even if large amount of AO transported into the interior through the longitudinal pores, the pure film showed good AO irradiation resistance owing to the basal plane of WS 2 crystal exhibiting much higher anti-oxidation capacity than the edge-plane. The composite film also had excellent AO irradiation resistance due to the formation of effective thinner WO 3 cladding layer in the sub-surface layer. Tribological results revealed that the composite films showed a significantly improved wear resistance, in comparison to the pure WS 2 film. Besides, due to the effective AO resistance, the tribological properties of WS 2 films remained almost unchanged before and after AO irradiation

  19. Modification of magnetoresistance and magnetic properties of Ni thin films by adding Dy interlayer

    Science.gov (United States)

    Vorobiov, S. I.; Shabelnyk, T. M.; Shutylieva, O. V.; Pazukha, I. M.; Chornous, A. M.

    2018-03-01

    The paper reports the influence of dysprosium (Dy) interlayer addition on structure, magnetoresistance and magnetic properties of nickel (Ni) thin films. Trilayer film systems Ni/Dy/Ni have been prepared by alternate electron-beam evaporation. It is demonstrated that all as-prepared and annealed Ni thin films have face-centered cubic structure. The composition of the samples after addition of the Dy interlayer corresponds to the combination of face-centered cubic (Ni) and hexagonal close-packed (Dy) structures. The structure of Ni/Dy/Ni film systems changes from amorphous to polycrystalline when Dy interlayer thickness (t Dy) is more than 15 nm. The value of magnetoresistance increases with the adding the Dy interlayer in both longitudinal and transverse geometries, meanwhile the anisotropic character of magnetoresistance field dependences retained. The saturation and reversal magnetizations are reduced with the increasing of the Dy thickness interlayer, while the coercivity takes the minimum value at t Dy = 15 nm. The following increasing of t Dy leads to increasing of coercivity near to three times. This result indicates the influence of the crystal structure on the magnetic properties of Ni thin films at adding Dy interlayer.

  20. Development and evaluation of a new baDge/filter for thermoluminescent monitoring with CaSO4: Dy/PTFE

    International Nuclear Information System (INIS)

    Campos, Vicente de Paula

    2005-01-01

    Calcium Sulfate (CaSO 4 :Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by the Instituto de Pesquisas Energeticas e Nucleares (IPEN), SP, Brazil since 70's and 80's, due to important work of its researchers and collaborators. This phosphor advantages, beside the fact that it is produced by IPEN itself, begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. This phosphors was used primarily in environmental and area monitoring at IPEN facilities and in a few external institutions, once it presents more sensibility than other phosphors, like LiF:Mg. Its mainly disadvantage is a strong energetic dependence response to ionizing radiation, which must be corrected for its application in every radiation field. This phosphor has been used inside a badge which is an adaptation from photographic film badges used in the past. This badge permits a reasonable correction in the energetic dependence, only for orthogonal beam incidence. With the objective of improve the performance and reduce the energetic dependence on any incidence angle, reducing the dose measurement uncertainty too, this work presents a study on a new badge, with a new filter geometry, and its performance was compared to the actual dosimeter in use, with significant improve on results. Gamma irradiations of 60 Co and x-rays of 25,1; 33; 37,3 and 82,1 keV, on incidence angles of 0 deg, 30 deg, 45 deg and 90 deg were done at facility conditions of IPEN. Semi-empirical computational simulation using finite differences in three dimensions were done. The results pointed out the best filter thickness and width for initiate the prototype production, in order to optimize the correction on energetic dependence on irradiation of photons of 33, 48, 118 and 1250 keV energies under many incidence angles. (author)

  1. Scaling of anomalous hall effect in amorphous CoFeB Films with accompanying quantum correction

    KAUST Repository

    Zhang, Yan

    2015-05-08

    Scaling of anomalous Hall effect in amorphous CoFeB films with thickness ranging from 2 to 160 nm have been investigated. We have found that the scaling relationship between longitudinal (ρxx) and anomalous Hall (ρAH) resistivity is distinctly different in the Bloch and localization regions. For ultrathin CoFeB films, the sheet resistance (Rxx) and anomalous Hall conductance (GAH) received quantum correction from electron localization showing two different scaling relationships at different temperature regions. In contrast, the thicker films show a metallic conductance, which have only one scaling relationship in the entire temperature range. Furthermore, in the dirty regime of localization regions, an unconventional scaling relationship View the MathML sourceσAH∝σxxα with α=1.99 is found, rather than α=1.60 predicted by the unified theory.

  2. Thermal and electrothermal sensitivity of polyglutamic acid with incorporated carbocyanine dyes in Langmuir-Blodgett films

    Energy Technology Data Exchange (ETDEWEB)

    Popova, G. [Mendeleyev University of Chemical Technology of Russia, Miusskaya sq., 9, Moscow 125047 (Russian Federation)], E-mail: galina@muctr.edu.ru; Spitsyn, A; Vantsyan, M [Mendeleyev University of Chemical Technology of Russia, Miusskaya sq., 9, Moscow 125047 (Russian Federation); Matveeva, N [Lukin Institute Phys. Problems, Zelenograd (Russian Federation); Yudin, S; Palto, S [Crystallography Institute Rus., Leninsky prosp., 57, 117336 Moscow (Russian Federation)

    2008-03-31

    Light-and electrosensitive carbocyanine dyes were incorporated into polyglutamic acid via covalent and non-covalent bonding. The reversible colour change on heating the Langmuir-Blodgett films of polyaminoacid has been studied by absorption spectroscopy and electroconductivity techniques. Characteristic shifts of the absorption spectrum are explained by formation of aggregates and hydrogen bonds. It was shown that H-aggregates and dimers are formed in Langmuir-Blodgett films; each type of assemblies contributes to the absorption spectrum. At elevated temperatures the ratio between concentrations of monomers, dimers and H-aggregates varies due to a breakdown of a part of aggregates into monomers. The change in molecular polarizability was also noticed. Electroconductivity of Langmuir-Blodgett films is observed in longitudinal and transverse directions. Electrochromic effect is noticed under weak electric current by change from red to colourless with iodine doping.

  3. Converting a major dosimetry service from film to optically stimulated luminescence dosemeters including revision of the 'back-office' software

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Faugoin, Stephane; Serise, Bertrand; Prugnaud, Brice; Million, Marc

    2008-01-01

    Full text: In our offices at Fontenay-aux-Roses we provide personal dosimetry for over 100,000 participants. During 2005/6 we transformed our operations from film dosemeters to those using Optically Stimulated Luminescence (InLight (Trade Mark)). The opportunity was taken to fully overhaul our operational procedures and we are currently completely reworking our 'back-office' software support. The change from film to InLight dosimetry has involved: 1) The installation of new readers at our offices in Fontenay-aux Roses; 2) The installation of a physical badge archiving system; 3) Complete revision of the operational flow to optimise the benefits of the new service; 4) Maintenance of our approval to operate a personal dosimetry service in France; 5) Considerable liaison between our office in Fontenay-aux-Roses and our Glenwood, USA, parent company to enable complete integration of the processes; and 6) Maintaining the service throughout the changeover and keeping client satisfaction high. Having changed the physical environment we are now completely renewing the back office software and systems in support of the dosimetry service. This ranges in scope from entering new clients, client support, all aspects of the dosimetry operations and chain of custody of the dosemeters and participants records and reports. This system is being rolled out in sections and it is envisaged that it will be fully implemented at the start of 2008. A key feature is that continuing improvement and the possibility of future developments of our services is in-built into the philosophy of the new back-office system. The nature of the new system, its benefits to our own operations and, in particular, clients will be discussed. (author)

  4. Electrical transport properties in Fe-Cr nanocluster-assembled granular films

    Science.gov (United States)

    Wang, Xiong-Zhi; Wang, Lai-Sen; Zhang, Qin-Fu; Liu, Xiang; Xie, Jia; Su, A.-Mei; Zheng, Hong-Fei; Peng, Dong-Liang

    2017-09-01

    The Fe100-xCrx nanocluster-assembled granular films with Cr atomic fraction (x) ranging from 0 to 100 were fabricated by using a plasma-gas-condensation cluster deposition system. The TEM characterization revealed that the uniform Fe clusters were coated with a Cr layer to form a Fe-Cr core-shell structure. Then, the as-prepared Fe100-xCrx nanoclusters were randomly assembled into a granular film in vacuum environments with increasing the deposition time. Because of the competition between interfacial resistance and shunting effect of Cr layer, the room temperature resistivity of the Fe100-xCrx nanocluster-assembled granular films first increased and then decreased with increasing the Cr atomic fraction (x), and revealed a maximum of 2 × 104 μΩ cm at x = 26 at.%. The temperature-dependent longitudinal resistivity (ρxx), magnetoresistance (MR) effect and anomalous Hall effect (AHE) of these Fe100-xCrx nanocluster-assembled granular films were also studied systematically. As the x increased from 0 to 100, the ρxx of all samples firstly decreased and then increased with increasing the measuring temperature. The dependence of ρxx on temperature could be well addressed by a mechanism incorporated for the fluctuation-induced-tunneling (FIT) conduction process and temperature-dependent scattering effect. It was found that the anomalous Hall effect (AHE) had no legible scaling relation in Fe100-xCrx nanocluster-assembled granular films. However, after deducting the contribution of tunneling effect, the scaling relation was unambiguous. Additionally, the Fe100-xCrx nanocluster-assembled granular films revealed a small negative magnetoresistance (MR), which decreased with the increase of x. The detailed physical mechanism of the electrical transport properties in these Fe100-xCrx nanocluster-assembled granular films was also studied.

  5. Ferroelectric and Piezoelectric properties of (111) oriented lanthanum modified lead zirconate titanate film

    International Nuclear Information System (INIS)

    Dutta, Soma; Antony Jeyaseelan, A.; Sruthi, S.

    2014-01-01

    Lanthanum modified lead zirconate titanate (PLZT) thick film with molecular formula of Pb 0.92 La 0.08 (Zr 0.52 Ti 0.48 ) 0.98 O 3 was grown preferentially along (111) direction on Pt/SiO 2 /Si (platinum/silicon oxide/silicon) substrate by spin coating of chemical solution. The directional growth of the film was facilitated by platinum (Pt) (111) template and rapid thermal annealing. X-ray diffraction pattern and atomic force microscopy revealed the preferential growth of the PLZT film. The film was characterized for ferroelectric and detailed piezoelectric properties in a parallel plate capacitor (metal–PLZT–metal) configuration. Ferroelectric characterization of the film showed saturated hysteresis loop with remanent polarization and coercive electric field values of 10.14 μC/cm 2 and 42 kV/cm, respectively, at an applied field of 300 kV/cm. Longitudinal piezoelectric coefficient (d 33,f ) was measured by employing converse piezoelectric effect where electrical charge response and displacement were measured with electrical voltage excitation on the sample electrodes. The effective transverse piezoelectric coefficient (e 31,f ) was derived from charge measurement with an applied mechanical excitation strain by using the four point bending method. d 33,f and e 31,f coefficients of PLZT films were found to be 380 pm/V and − 0.831 C/m 2 respectively. - Highlights: • PLZT (111) film is prepared by spin coating of chemical sol on Pt (111) template. • Piezoelectric d 33 value (380 pm/V) of PLZT film is found 20% higher than PZT. • Transverse piezocoefficient e 31,f of PLZT film is reported for the first time

  6. Raman scattering and Rutherford backscattering studies on InN films grown by plasma-assisted molecular beam epitaxy

    International Nuclear Information System (INIS)

    Chung, Yee Ling; Peng Xingyu; Liao, Ying Chieh; Yao Shude; Chen, Li Chyong; Chen, Kuei Hsien; Feng, Zhe Chuan

    2011-01-01

    A series of InN thin films was grown on sapphire substrates via plasma-assisted molecular beam epitaxy (PA-MBE) with different nitrogen plasma power. Various characterization techniques, including Hall, photoluminescence, Raman scattering and Rutherford backscattering, have been employed to study these InN films. Good crystalline wurtzite structures have been identified for all PA-MBE grown InN films on sapphire substrate, which have narrower XRD wurtzite (0002) peaks, showed c-axis Raman scattering allowed longitudinal optical (LO) modes of A 1 and E 1 plus E 2 symmetry, and very weak backscattering forbidden transverse optical (TO) modes. The lower plasma power can lead to the lower carrier concentration, to have the InN film close to intrinsic material with the PL emission below 0.70 eV. With increasing the plasma power, high carrier concentration beyond 1 x 10 20 cm -3 can be obtained, keeping good crystalline perfection. Rutherford backscattering confirmed most of InN films keeping stoichiometrical In/N ratios and only with higher plasma power of 400 W leaded to obvious surface effect and interdiffusion between the substrate and InN film.

  7. Evaluation of radiation exposure from a consumer product. A pillow

    International Nuclear Information System (INIS)

    Furuta, Etsuko; Aburai, Tamaru

    1999-01-01

    Radiation exposure from a pillow was analyzed. According to an advertisement of the pillow, this radioactive consumer product contains enough amounts of radioactive materials to induce radiation hormesis effects. The pillow consists of the filling chips made from kneading mineral ores and the polynosic linings contains natural radioactive ores. A γ-ray analysis of the pillow using pure Ge-MCA reveals that there exist radioactivities of thorium and uranium series mixtures in it at concentration of 0.58% by the weight. The observations of a chip surface by a scanning electron microscope show that the shapes of two sides are different each other. There are lots of sharp protuberances on the outside of the chip. To determine the direct external exposures from the pillow, film badges were placed on the pillow for 210 h and 2555 h. The dose equivalents of 210 h exposure was under 0.1 mSv which is a detection limit of a γ-ray by the film badges. However, that of 2555 h exposure was over 0.1 mSv less than 0.15 mSv. Quantities of internal exposures from inhalation of the vaporized Rn were measured by a Lucas Cell. It was 79 Bq/m 3 . There is no necessity for anxious about being broken in health inhaling the Rn-gass. (author)

  8. Ferroelectric and piezoelectric responses of (110) and (001)-oriented epitaxial Pb(Zr{sub 0.52}Ti{sub 0.48})O{sub 3} thin films on all-oxide layers buffered silicon

    Energy Technology Data Exchange (ETDEWEB)

    Vu, Hien Thu [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology, No.1 Dai Co Viet Road, Hanoi 10000 (Viet Nam); Nguyen, Minh Duc, E-mail: minh.nguyen@itims.edu.vn [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology, No.1 Dai Co Viet Road, Hanoi 10000 (Viet Nam); Inorganic Materials Science (IMS), MESA + Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede (Netherlands); SolMateS B.V., Drienerlolaan 5, Building 6, 7522 NB Enschede (Netherlands); Houwman, Evert; Boota, Muhammad [Inorganic Materials Science (IMS), MESA + Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede (Netherlands); Dekkers, Matthijn [SolMateS B.V., Drienerlolaan 5, Building 6, 7522 NB Enschede (Netherlands); Vu, Hung Ngoc [International Training Institute for Materials Science (ITIMS), Hanoi University of Science and Technology, No.1 Dai Co Viet Road, Hanoi 10000 (Viet Nam); Rijnders, Guus [Inorganic Materials Science (IMS), MESA + Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE Enschede (Netherlands)

    2015-12-15

    Graphical abstract: The cross sections show a very dense structure in the (001)-oriented films (c,d), while an open columnar growth structure is observed in the case of the (110)-oriented films (a,b). The (110)-oriented PZT films show a significantly larger longitudinal piezoelectric coefficient (d33{sub ,f}), but smaller transverse piezoelectric coefficient (d31{sub ,f}) than the (001) oriented films. - Highlights: • We fabricate all-oxide, epitaxial piezoelectric PZT thin films on Si. • The orientation of the films can be controlled by changing the buffer layer stack. • The coherence of the in-plane orientation of the grains and grain boundaries affects the ferroelectric properties. • Good cycling stability of the ferroelectric properties of (001)-oriented PZT thin films. The (110)-oriented PZT thin films show a larger d33{sub ,f} but smaller d31{sub ,f} than the (001)-oriented films. - Abstract: Epitaxial ferroelectric Pb(Zr{sub 0.52}Ti{sub 0.48})O{sub 3} (PZT) thin films were fabricated on silicon substrates using pulsed laser deposition. Depending on the buffer layers and perovskite oxide electrodes, epitaxial films with different orientations were grown. (110)-oriented PZT/SrRuO{sub 3} (and PZT/LaNiO{sub 3}) films were obtained on YSZ-buffered Si substrates, while (001)-oriented PZT/SrRuO{sub 3} (and PZT/LaNiO{sub 3}) were fabricated with an extra CeO{sub 2} buffer layer (CeO{sub 2}/YSZ/Si). There is no effect of the electrode material on the properties of the films. The initial remnant polarizations in the (001)-oriented films are higher than those of (110)-oriented films, but it increases to the value of the (001) films upon cycling. The longitudinal piezoelectric d33{sub ,f} coefficients of the (110) films are larger than those of the (001) films, whereas the transverse piezoelectric d31{sub ,f} coefficients in the (110)-films are less than those in the (001)-oriented films. The difference is ascribed to the lower density (connectivity between

  9. High-energy neutron dosimetry at the Clinton P. Anderson Meson Physics Facility

    International Nuclear Information System (INIS)

    Mallett, M.W.; Vasilik, D.G.; Littlejohn, G.J.; Cortez, J.R.

    1990-01-01

    Neutron energy spectrum measurements performed at the Clinton P. Anderson Meson Physics Facility indicated potential areas for high energy neutron exposure to personnel. The low sensitivity of the Los Alamos thermoluminescent dosimeter (TLD) to high energy neutrons warranted issuing a NTA dosimeter in addition to the TLD badge to employees entering these areas. The dosimeter consists of a plastic holder surrounding NTA film that has been desiccated and sealed in a dry nitrogen environment. A study of the fading of latent images in NTA film demonstrated the success of this packaging method to control the phenomenon. The Los Alamos NTA dosimeter is characterized and the fading study discussed. 10 refs., 4 figs., 2 tabs

  10. Exploring Longitudinal Risk-return Relationships

    DEFF Research Database (Denmark)

    Andersen, Torben J.; Bettis, Richard A.

    2015-01-01

    We study a longitudinal fit model of adaptation and its association with the longitudinal risk-return relationship. The model allows the firm to adjust its position in response to partial learning about a changing environment characterized by two path-dependent processes—a random walk and a stoch......We study a longitudinal fit model of adaptation and its association with the longitudinal risk-return relationship. The model allows the firm to adjust its position in response to partial learning about a changing environment characterized by two path-dependent processes—a random walk...... can lead to the inverse longitudinal risk-return relationships observed empirically. We discuss this apparent paradox and the possible resolution between mindless and conscious behavior as plausible causes of the longitudinal Bowman Paradox....

  11. United We Fall

    OpenAIRE

    Whiles, Annie; Pearson, Mark

    2008-01-01

    Standpoint is pleased to present new drawings, objects and film by Mark Pearson and Annie Whiles. The artists share an interest in the emblematic: re-negotiating visual structures that signify affiliation and commemoration. Things such as crests, mascots, badges and motifs that reflect activities, rituals and artifacts that might be attached to a clubhouse or headquarters, church or local pub.\\ud \\ud As both artists move their ‘HQ’ into the gallery you will be invited to contemplate works tha...

  12. Quality control and quality assurance philosophy introduced in national personnel dosimetry service

    International Nuclear Information System (INIS)

    Trousil, J.; Zelenka, Z.; Kvasnicka, O.

    2008-01-01

    There in National Personnel Dosimetry Service (NPDS) the implementation of the control system to guarantee the credibility of the measured personal dose equivalents results was given on the basis of the international recommendations published by the European Commission and the IAEA and in particular of the decree of the SUJB No. 132/2008 Coll. The quality control and the quality assurance are carried out in all three personal dosimetry services introduced in NPDS: in the film badge, thermoluminescent (TL) and neutron dosimetry. (authors)

  13. Scaling of the anomalous Hall current in Fe100−x(SiO2)x films

    KAUST Repository

    Xu, W. J.

    2011-05-20

    To study the origin of the anomalous Hall effect, Fe100−x(SiO2)x granular films with a volume fraction of SiO2 (0 ⩽ x ⩽ 40.51) were fabricated using cosputtering. Hall and longitudinal resistivities were measured in the temperature range of 5–350 K with magnetic fields up to 5 T. As x increased from 0 to 40.51, the anomalous Hall resistivity and longitudinal resistivity increased by about four and three orders in magnitude, respectively. Analysis of the results revealed that the normalized anomalous Hall conductivity is a constant for all of the samples, which may suggest a scattering-independent anomalous Hall conductivity in Fe.

  14. Longitudinal categorical data analysis

    CERN Document Server

    Sutradhar, Brajendra C

    2014-01-01

    This is the first book in longitudinal categorical data analysis with parametric correlation models developed based on dynamic relationships among repeated categorical responses. This book is a natural generalization of the longitudinal binary data analysis to the multinomial data setup with more than two categories. Thus, unlike the existing books on cross-sectional categorical data analysis using log linear models, this book uses multinomial probability models both in cross-sectional and longitudinal setups. A theoretical foundation is provided for the analysis of univariate multinomial responses, by developing models systematically for the cases with no covariates as well as categorical covariates, both in cross-sectional and longitudinal setups. In the longitudinal setup, both stationary and non-stationary covariates are considered. These models have also been extended to the bivariate multinomial setup along with suitable covariates. For the inferences, the book uses the generalized quasi-likelihood as w...

  15. Evaluation of Intrinsic Shear Piezoelectric Coefficient d15 of c-Axis Oriented Pb(Zr,Ti)O3 Films

    Science.gov (United States)

    Kanno, Isaku; Akama, Kenji; Wasa, Kiyotaka; Kotera, Hidetoshi

    2009-09-01

    Piezoelectric shear strain was measured for c-axis oriented epitaxial Pb(Zr,Ti)O3 (PZT) thin films. The PZT films, with a composition near the morphotropic phase boundary (MPB), were epitaxially grown on (001) MgO substrates and then microfabricated into a rectangular shape by wet etching of the films. Lateral electrodes were deposited on both sides of the PZT films, to apply an external electric field perpendicular to the polarization. A sinusoidal input voltage of 100 kHz was applied between the lateral electrodes, and in-plane shear vibration was measured by a laser Doppler vibrometer. In-plane displacement due to shear mode piezoelectric vibration was clearly observed and increased proportionally with the voltage. Finite element method (FEM) analysis was conducted to determine the horizontal electric field in the PZT film, and the piezoelectric coefficient d15 was calculated to be 440×10-12 m/V. The d15 of the PZT film represents the intrinsic shear piezoelectric effect, which is slightly smaller than that of bulk PZT, due to the absence of extrinsic effects such as longitudinal and transverse piezoelectric strain or domain rotation.

  16. Growth of porous type anodic oxide films at micro-areas on aluminum exposed by laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Tatsuya [Graduate School of Engineering, Hokkaido University, N13-W8, Kita-Ku, Sapporo 060-8628 (Japan)], E-mail: kiku@eng.hokudai.ac.jp; Sakairi, Masatoshi [Graduate School of Engineering, Hokkaido University, N13-W8, Kita-Ku, Sapporo 060-8628 (Japan); Takahashi, Hideaki [Asahikawa National College of Technology, Syunkohdai, 2-2, 1-6, Asahikawa 071-8142 (Japan)

    2009-11-30

    Aluminum covered with pore-sealed anodic oxide films was irradiated with a pulsed Nd-YAG laser to remove the oxide film at micro-areas. The specimen was re-anodized for long periods to examine the growth of porous anodic oxide films at the area where substrate had been exposed by measuring current variations and morphological changes in the oxide during the re-anodizing. The chemical dissolution resistance of the pore-sealed anodic oxide films in an oxalic acid solution was also examined by measuring time-variations in rest potentials during immersion. The resistance to chemical dissolution of the oxide film became higher with increasing pore-sealing time and showed higher values at lower solution temperatures. During potentiostatic re-anodizing at five 35-{mu}m wide and 4-mm long lines for 72 h after the film was removed the measured current was found to increase linearly with time. Semicircular columnar-shaped porous type anodic oxide was found to form during the re-anodizing at the laser-irradiated area, and was found to grow radially, thus resulting in an increase in the diameter. After long re-anodizing, the central and top parts of the oxide protruded along the longitudinal direction of the laser-irradiated area. The volume expansion during re-anodizing resulted in the formation of cracks, parallel to the lines, in the oxide film formed during the first anodizing.

  17. Ferroelectric and Piezoelectric properties of (111) oriented lanthanum modified lead zirconate titanate film

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, Soma, E-mail: som@nal.res.in; Antony Jeyaseelan, A.; Sruthi, S.

    2014-07-01

    Lanthanum modified lead zirconate titanate (PLZT) thick film with molecular formula of Pb{sub 0.92}La{sub 0.08}(Zr{sub 0.52}Ti{sub 0.48}){sub 0.98}O{sub 3} was grown preferentially along (111) direction on Pt/SiO{sub 2}/Si (platinum/silicon oxide/silicon) substrate by spin coating of chemical solution. The directional growth of the film was facilitated by platinum (Pt) (111) template and rapid thermal annealing. X-ray diffraction pattern and atomic force microscopy revealed the preferential growth of the PLZT film. The film was characterized for ferroelectric and detailed piezoelectric properties in a parallel plate capacitor (metal–PLZT–metal) configuration. Ferroelectric characterization of the film showed saturated hysteresis loop with remanent polarization and coercive electric field values of 10.14 μC/cm{sup 2} and 42 kV/cm, respectively, at an applied field of 300 kV/cm. Longitudinal piezoelectric coefficient (d{sub 33,f}) was measured by employing converse piezoelectric effect where electrical charge response and displacement were measured with electrical voltage excitation on the sample electrodes. The effective transverse piezoelectric coefficient (e{sub 31,f}) was derived from charge measurement with an applied mechanical excitation strain by using the four point bending method. d{sub 33,f} and e{sub 31,f} coefficients of PLZT films were found to be 380 pm/V and − 0.831 C/m{sup 2} respectively. - Highlights: • PLZT (111) film is prepared by spin coating of chemical sol on Pt (111) template. • Piezoelectric d{sub 33} value (380 pm/V) of PLZT film is found 20% higher than PZT. • Transverse piezocoefficient e{sub 31,f} of PLZT film is reported for the first time.

  18. Smoking in Movies and Adolescent Smoking Initiation: A Longitudinal Study among Argentinian Adolescents.

    Science.gov (United States)

    Mejia, Raul; Pérez, Adriana; Peña, Lorena; Kollath-Cattano, Christy; Morello, Paola; Braun, Sandra; Hardin, James W; Thrasher, James F; Sargent, James D

    2017-01-01

    To assess whether exposure to movie smoking is associated with cigarette smoking among Argentinian adolescents. A school-based longitudinal study involving 33 secondary schools in Argentina was performed. The sample included 2502 never smokers (average age at entry = 12.5 years), 1700 (67.9%) of whom completed follow-up surveys 17 months later. Exposure to the top 100 highest-grossing films for each year between 2009 and 2013 was assessed by content-coding films for tobacco and then by asking adolescents whether they had seen each of 50 titles, randomly selected from the larger pool, then parsing exposure into tertiles. Logistic regression models estimated aOR for the following transitions: nonsusceptible to susceptible never smoker, never smoker to ever smoker, and never smoker to current smoking (last 30 days). At follow-up, 34.4% of nonsusceptible never smokers became susceptible, 24.1% reported having tried smoking, and 9.4% were current smokers. Most exposure to movie smoking was from US-produced films (average 60.3 minutes compared with only 3.4 minutes from Argentine films). Greater exposure to smoking in movies was significantly associated with increased odds of becoming susceptible (aOR first vs third tertile  1.77, 95% CI 1.30-2.41), of trying smoking (aOR first vs third tertile  1.54, 1.14-2.08), and marginally associated with current smoking (AOR first vs third tertile  1.54, 0.99-2.40). Exposure to smoking in US- or Argentine-produced films had similar associations. In Argentina, exposure to smoking in the movies predicted future smoking transitions among early adolescents, with most exposure coming from viewing US movies. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Smoking in Movies and Adolescent Smoking Initiation: A Longitudinal Study among Argentinian Adolescents

    Science.gov (United States)

    Mejia, Raul; Pérez, Adriana; Peña, Lorena; Kollath-Cattano, Christy; Morello, Paola; Braun, Sandra; Hardin, James W.; Thrasher, James F.; Sargent, James

    2016-01-01

    Objective To assess whether exposure to movie smoking is associated with cigarette smoking among Argentinian adolescents. Study design School-based longitudinal study involving 33 secondary schools in Argentina. The sample included 2502 never smokers (average age at entry =12.5y), 1,700 (67.9%) of whom completed follow-up surveys 17 months later. Exposure to the top 100 grossing films for each year between 2009 and 2013 was assessed by content-coding films for tobacco, and then asking adolescents whether they had seen each of 50 titles, randomly selected from the larger pool, then parsing exposure into tertiles. Logistic regression models estimated adjusted odds ratio (AOR) for the following transitions: non-susceptible to susceptible never smoker, never smoker to ever smoker, and never smoker to current smoking (last 30 days). Results At follow-up, 34.4% of non-susceptible never smokers became susceptible, 24.1% reported having tried smoking, and 9.6% were current smokers. Most exposure to movie smoking was from US-produced films (average 60.3 minutes compared with only 3.4 minutes from Argentine films). Higher exposure to smoking in movies was significantly associated with increased odds of becoming susceptible (AOR1st vs 3rd tertile = 1.77, 95% confidence interval 1.30–2.41), of trying smoking (AOR1st vs 3rd tertile = 1.54, 1.14–2.08), and marginally associated with current smoking (AOR1st vs 3rd tertile = 1.54, 0.99–2.40). Exposure to smoking in US- or Argentine-produced films had similar associations. Conclusion In Argentina, exposure to smoking in the movies predicted future smoking transitions among early adolescents, with most exposure coming from viewing US movies. PMID:28029343

  20. TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Schueler, B; Grams, M [Mayo Clinic, Rochester, MN (United States); Sturchio, G [Mayo Clinic, Jacksonville, FL (United States)

    2016-06-15

    Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Direct exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.

  1. Brillouin light scattering studies of the mechanical properties of ultrathin low-k dielectric films

    Science.gov (United States)

    Link, A.; Sooryakumar, R.; Bandhu, R. S.; Antonelli, G. A.

    2006-07-01

    In an effort to reduce RC time delays that accompany decreasing feature sizes, low-k dielectric films are rapidly emerging as potential replacements for silicon dioxide (SiO2) at the interconnect level in integrated circuits. The main challenge in low-k materials is their substantially weaker mechanical properties that accompany the increasing pore volume content needed to reduce k. We show that Brillouin light scattering is an excellent nondestructive technique to monitor and characterize the mechanical properties of these porous films at thicknesses well below 200nm that are pertinent to present applications. Observation of longitudinal and transverse standing wave acoustic resonances and the dispersion that accompany their transformation into traveling waves with finite in-plane wave vectors provides for a direct measure of the principal elastic constants that completely characterize the mechanical properties of these ultrathin films. The mode amplitudes of the standing waves, their variation within the film, and the calculated Brillouin intensities account for most aspects of the spectra. We further show that the values obtained by this method agree well with other experimental techniques such as nanoindentation and picosecond laser ultrasonics.

  2. Black Films and Film-Makers.

    Science.gov (United States)

    Patterson, Lindsay, Ed.

    The development of black films and the attitudes of the film industry toward black films and black actors are some of the topics examined in this anthology of essays. Section 1, "Nigger to Supernigger," contains such articles as "The Death of Rastus: Negroes in American Films" by Thomas R. Cripps and "Folk Values in a New Medium" by Alain Locke…

  3. Verification by the FISH translocation assay of historic doses to Mayak workers from external gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sotnik, Natalia V.; Azizova, Tamara V. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Darroudi, Firouz [Leiden University Medical Center, Department of Toxicogenetics, Leiden (Netherlands); College of North Atlantic, Department of Health Science, Centre for Human Safety and Environmental Research, Doha (Qatar); Ainsbury, Elizabeth A.; Moquet, Jayne E.; Lloyd, David C.; Hone, Pat A.; Edwards, Alan A. [Public Health England, Chilton, Oxfordshire (United Kingdom); Fomina, Janna [Leiden University Medical Center, Department of Toxicogenetics, Leiden (Netherlands)

    2015-11-15

    The aim of this study was to apply the fluorescence in situ hybridization (FISH) translocation assay in combination with chromosome painting of peripheral blood lymphocytes for retrospective biological dosimetry of Mayak nuclear power plant workers exposed chronically to external gamma radiation. These data were compared with physical dose estimates based on monitoring with badge dosimeters throughout each person's working life. Chromosome translocation yields for 94 workers of the Mayak production association were measured in three laboratories: Southern Urals Biophysics Institute, Leiden University Medical Center and the former Health Protection Agency of the UK (hereinafter Public Health England). The results of the study demonstrated that the FISH-based translocation assay in workers with prolonged (chronic) occupational gamma-ray exposure was a reliable biological dosimeter even many years after radiation exposure. Cytogenetic estimates of red bone marrow doses from external gamma rays were reasonably consistent with dose measurements based on film badge readings successfully validated in dosimetry system ''Doses-2005'' by FISH, within the bounds of the associated uncertainties. (orig.)

  4. Characteristics of radiophotoluminescent glass dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Masashi; Shiraishi, Akemi; Murakami, Hiroyuki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-07-01

    In Japan Atomic Energy Research Institute, a film badge is recently replaced by a new type radiophotoluminescent (RPL) glass dosimeter for external personal monitoring. Some fundamental characteristics of this dosimeter, such as dose dependence linearity, energy dependence, angular dependence, dose evaluation accuracy at mixed irradiation conditions, fading, etc., were examined at the Facility of Radiation Standard (FRS), JAERI. The results have proved that the RPL glass dosimeter has sufficient characteristics for practical use as a personal dosimeter for all of the items examined. (author)

  5. Electronic dosimeter characteristics and new developments

    International Nuclear Information System (INIS)

    Thompson, I.M.G.

    1999-01-01

    Electronic dosimeters are very much more versatile than existing passive dosimeters such as TLDs and film badges which have previously been the only type of dosimeters approved by national authorities for the legal measurement of doses to occupationally exposed workers. Requirements for the specifications and testing of electronic dosimeters are given in the standards produced by the International Electrotechnical Commission Working Group IEC SC45B/B8. A description is given of these standards and the use of electronic dosimeters as legal dosimeters is discussed. (author)

  6. Decoding of digital magnetic recording with longitudinal magnetization of a tape from a magneto-optical image of stray fields

    Science.gov (United States)

    Lisovskii, F. V.; Mansvetova, E. G.

    2017-05-01

    For digital magnetic recording of encoded information with longitudinal magnetization of the tape, the connection between the domain structure of a storage medium and magneto-optical image of its stray fields obtained using a magnetic film with a perpendicular anisotropy and a large Faraday rotation has been studied. For two-frequency binary code without returning to zero, an algorithm is developed, that allows uniquely decoding of the information recorded on the tape based on analysis of an image of stray fields.

  7. Annealing behaviour of structural and magnetic properties of evaporated Co thin films

    International Nuclear Information System (INIS)

    Jergel, M; Halahovets, Y; Siffalovic, P; Mat'ko, I; Senderak, R; Majkova, E; Luby, S; Cheshko, I; Protsenko, S

    2009-01-01

    Cobalt thin films of 50 nm nominal thickness were e-beam evaporated on silicon substrates covered with thermal oxide. Two series of independent and cumulative vacuum annealings up to 600 deg. C and 650 deg. C, respectively, were performed. The x-ray diffraction, specular and non-specular x-ray reflectivity and longitudinal magneto-optical Kerr effect measurements were applied to probe the annealing behaviour of the film structure and magnetic properties. A gradual transition from the hexagonal close-packed (hcp) to the face-centred cubic (fcc) structure was observed. Evolution of the in-plane magnetic anisotropy is dominated by residual stresses which relax during the structural transformation. The coercivity follows the stress behaviour in the hcp phase up to 300 deg. C and increases abruptly above 400 deg. C due to improving the magneto-crystalline anisotropy in the growing fcc crystallites and enhanced surface/interface roughness.

  8. Film quality in film mammography. Pt. 2

    International Nuclear Information System (INIS)

    Friedrich, M.; Weskamp, P.; Freie Univ. Berlin

    1976-01-01

    During consideration of three film mammographic systems, the concept of signal/noise ratio is developed as a quantitative measure of film quality. The ability to recognise detail related to detail size, film blackening and exposure geometry was studied for various systems, and the quality profiles are discussed. There is a considerable difference in quality between industrial films without screens and film-screen combinations; however, exposure geometry during mammography has a considerable effect which tends to reduce the difference. Consequently, detail sizes of 200 μ to 1,000 μ (including the majority of mammographic micro-calcifications) are shown about equally well. Contrast for the lo-dose system is somewhat less than for adequately exposed industrial film. Over-exposure with the lo-dose system, contrary to industrial film, rapidly leads to unsatisfactory results. On the other hand it is often not possible to obtain an adequate exposure when using industrial film. For these reasons it is often an advantage to examine large breasts and the dense breasts of young women with a film-screen combination which requires approximately one eighth of the dose necessary for industrial film. For small or easily compressable breasts best results are obtained, using an adequate exposure by employing industril film; radiation dose it then acceptable. (orig./ORU) [de

  9. Comparison of scatter doses from a multislice and a single slice CT scanner

    International Nuclear Information System (INIS)

    Burrage, J. W.; Causer, D. A.

    2006-01-01

    During shielding calculations for a new multislice CT (MSCT) scanner it was found that the manufacturer's data indicated significantly higher external scatter doses than would be generated for a single slice CT (SSCT). Even allowing for increased beam width, the manufacturer's data indicated that the scatter dose per scan was higher by a factor of about 3 to 4. The magnitude of the discrepancy was contrary to expectations and also contrary to a statement by the UK ImPACT group, which indicated that when beam width is taken into account, the scatter doses should be similar. The matter was investigated by comparing scatter doses from an SSCT and an MSCT. Scatter measurements were performed at three points using a standard perspex CTDI phantom, and CT dose indices were also measured to compare scanner output. MSCT measurements were performed with a 40 mm wide beam, SSCT measurements with a 10 mm wide beam. A film badge survey was also performed after the installation of the MSCT scanner to assess the adequacy of lead shielding in the room. It was found that the scatter doses from the MSCT were lower than indicated by the manufacturer's data. MSCT scatter doses were approximately 4 times higher than those from the SSCT, consistent with expectations due to beam width differences. The CT dose indices were similar, and the film badge survey indicated that the existing shielding, which had been adequate for the SSCT, was also adequate for the MSCT

  10. Inferring Person-to-person Proximity Using WiFi Signals

    DEFF Research Database (Denmark)

    Sapiezynski, Piotr; Stopczynski, Arkadiusz; Wind, David Kofoed

    2017-01-01

    scale is a technical challenge and many commonly used approaches—including RFID badges or Bluetooth scanning—offer only limited scalability. Here we show that it is possible, in a scalable and robust way, to accurately infer person-to-person physical proximity from the lists of WiFi access points...... measured by smartphones carried by the two individuals. Based on a longitudinal dataset of approximately 800 participants with ground-truth interactions collected over a year, we show that our model performs better than the current state-of-the-art. Our results demonstrate the value of WiFi signals...

  11. Longitudinal and transverse digital image reconstruction with a tomographic scanner

    International Nuclear Information System (INIS)

    Pickens, D.R.; Price, R.R.; Erickson, J.J.; Patton, J.A.; Partain, C.L.; Rollo, F.D.

    1981-01-01

    A Siemens Gammasonics PHO/CON-192 Multiplane Imager is interfaced to a digital computer for the purpose of performing tomographic reconstructions from the data collected during a single scan. Data from the two moving gamma cameras as well as camera position information are sent to the computer by an interface designed in the authors' laboratory. Backprojection reconstruction is implemented by the computer. Longitudinal images in whole-body format as well as smaller formats are reconstructed for up to six planes simultaneously from the list mode data. Transverse reconstructions are demonstrated for 201 T1 myocardial scans. Post-reconstruction deconvolution processing to remove the blur artifact (characteristic of focal plane tomography) is applied to a multiplane phantom. Digital data acquisition of data and reconstruction of images are practical, and can extend the usefulness of the machine when compared with the film output (author)

  12. Optical properties of Mn doped ZnO films and wires synthesized by thermal oxidation of ZnMn alloy

    International Nuclear Information System (INIS)

    Sima, M.; Mihut, L.; Vasile, E.; Sima, Ma.; Logofatu, C.

    2015-01-01

    Mn doped ZnO films and wires, having different manganese concentrations were synthesized by thermal oxidation of the corresponding ZnMn alloy films and wires electrodeposited on a gold substrate. Structural and optical properties were addressed with scanning electron microscopy, X-ray diffraction (XRD), Raman scattering and photoluminescence (PL). To estimate the manganese concentration in Mn doped ZnO films, X-ray photoelectron spectroscopy was used. XRD patterns indicate that the incorporation of Mn 2+ ions into the Zn 2+ site of ZnO lattice takes place. Quenching of the ZnO PL appears due to Mn 2+ ions in the ZnO lattice. Moreover, a significant decrease in the green emission of ZnO is reported in the case of the Mn doped ZnO wire array with a Mn concentration of 1.45%. The wurtzite ZnO has a total of 12 phonon modes, namely, one longitudinal acoustic (LA), two transverse acoustic (TA), three longitudinal optical (LO), and six transverse optical branches. Compared to the undoped ZnO, a gradual up-shift of the Raman lines assigned to the 2LA and A 1 (LO) vibrational modes, from 482 and 567 cm −1 to 532 and 580 cm −1 , respectively, takes place for the Mn doped ZnO films having a Mn concentration between 2 and 15%. Additionally, in the case of the Mn doped ZnO films with 7 and 15% Mn concentration, Raman spectra show the appearance and increase in the relative intensity of the ZnO Raman line assigned to the TA + LO vibrational mode in the 600–750 cm −1 spectral range. For the Mn-doped ZnO wires, the presence of the Raman line peaking at 527 cm −1 confirms the insertion of Mn 2+ ions in ZnO lattice. - Highlights: • Mn doped ZnO films and wires grown by thermal oxidation of ZnMn alloy • Incorporation of Mn 2+ ions into Zn 2+ site of ZnO lattice • Appearance of a strong Raman line in the spectral range 600–800 cm −1 at high Mn concentration • Compensation of the oxygen vacancy at higher Mn concentration in ZnO lattice

  13. Magnetotransport in nanocrystalline SmB6 thin films

    Directory of Open Access Journals (Sweden)

    Jie Yong

    2015-07-01

    Full Text Available SmB6 has been predicted to be a prototype of topological Kondo insulator (TKI but its direct experimental evidence as a TKI is still lacking to date. Here we report on our search for the signature of a topological surface state and investigation of the effect of disorder on transport properties in nanocrystalline SmB6 thin films through longitudinal magnetoresistance and Hall coefficient measurements. The magnetoresistance (MR at 2 K is positive and linear (LPMR at low field and become negative and quadratic at higher field. While the negative part is understood from the reduction of the hybridization gap due to Zeeman splitting, the positive dependence is similar to what is observed in other topological insulators (TI. We conclude that the LPMR is a characteristic of TI and is related to the linear dispersion near the Dirac cone. The Hall resistance shows a sign change around 50K. It peaks and becomes nonlinear around 10 K then decreases below 10 K. This indicates that carriers with opposite signs emerge below 50 K. These properties indicate that the surface states are robust and probably topological in our nanocrystalline films.

  14. A computer database system to calculate staff radiation doses and maintain records

    International Nuclear Information System (INIS)

    Clewer, P.

    1985-01-01

    A database has been produced to record the personal dose records of all employees monitored for radiation exposure in the Wessex Health Region. Currently there are more than 2000 personnel in 115 departments but the capacity of the database allows for expansion. The computer is interfaced to a densitometer for film badge reading. The hardware used by the database, which is based on a popular microcomputer, is described, as are the various programs that make up the software. The advantages over the manual card index system that it replaces are discussed. (author)

  15. Occupational external radiation exposure in the GDR in 1976

    International Nuclear Information System (INIS)

    Rothe, W.

    1980-01-01

    In 1976 a total of 36,794 occupationally exposed persons were monitored by the National Board of Nuclear Safety and Radiation Protection, using film badges. The monthly over-exposures (more than 4 mGy) totalled 415. In 11 cases the monthly exposure exceeded 30 mGy and 6 annual exposure values were in the range of 50 to 120 mGy. An attempt has been made to assess the annual collective and annual per caput doses for the exposed population as a whole and some subgroups without completely summing up the individual exposure data. (author)

  16. Occupational radiation exposure in the GDR in 1973

    International Nuclear Information System (INIS)

    Koenig, W.; Larssen, A.; Rothe, W.

    1977-01-01

    In 1973 a total of 36,481 occupationally exposed persons were monitored by the central film badge service of the National Board of Nuclear Safety and Radiation Protection. The monthly over-exposure (more than 0,4 rad) totalled 610. In 37 cases the quarterly dose (3 rad) was exceeded during one month and 29 of these records could be assessed as real over-exposures. Most of the over-exposure could be attributed to an insufficient application of safety regulations. The results were analysed according to type of institution as well as sex of employees. (author)

  17. Fabrication of thermally evaporated Al thin film on cylindrical PET monofilament for wearable computing devices

    Science.gov (United States)

    Liu, Yang; Kim, Eunju; Han, Jeong In

    2016-01-01

    During the initial development of wearable computing devices, the conductive fibers of Al thin film on cylindrical PET monofilament were fabricated by thermal evaporation. Their electrical current-voltage characteristics curves were excellent for incorporation into wearable devices such as fiber-based cylindrical capacitors or thin film transistors. Their surfaces were modified by UV exposure and dip coating of acryl or PVP to investigate the surface effect. The conductive fiber with PVP coating showed the best conductivities because the rough surface of the PET substrate transformed into a smooth surface. The conductivities of PET fiber with and without PVP were 6.81 × 103 Ω-1cm-1 and 5.62 × 103 Ω-1cm-1, respectively. In order to understand the deposition process of Al thin film on cylindrical PET, Al thin film on PET fiber was studied using SEM (Scanning Electron Microscope), conductivities and thickness measurements. Hillocks on the surface of conductive PET fibers were observed and investigated by AFM on the surface. Hillocks were formed and grown during Al thermal evaporation because of severe compressive strain and plastic deformation induced by large differences in thermal expansion between PET substrate and Al thin film. From the analysis of hillock size distribution, it turns out that hillocks grew not transversely but longitudinally. [Figure not available: see fulltext.

  18. Influence of film dimensions on film droplet formation.

    Science.gov (United States)

    Holmgren, Helene; Ljungström, Evert

    2012-02-01

    Aerosol particles may be generated from rupturing liquid films through a droplet formation mechanism. The present work was undertaken with the aim to throw some light on the influence of film dimensions on droplet formation with possible consequences for exhaled breath aerosol formation. The film droplet formation process was mimicked by using a purpose-built device, where fluid films were spanned across holes of known diameters. As the films burst, droplets were formed and the number and size distributions of the resulting droplets were determined. No general relation could be found between hole diameter and the number of droplets generated per unit surface area of fluid film. Averaged over all film sizes, a higher surface tension yielded higher concentrations of droplets. Surface tension did not influence the resulting droplet diameter, but it was found that smaller films generated smaller droplets. This study shows that small fluid films generate droplets as efficiently as large films, and that droplets may well be generated from films with diameters below 1 mm. This has implications for the formation of film droplets from reopening of closed airways because human terminal bronchioles are of similar dimensions. Thus, the results provide support for the earlier proposed mechanism where reopening of closed airways is one origin of exhaled particles.

  19. Centimeter-order view for magnetic domain imaging with local magnetization direction by longitudinal Kerr effect

    Directory of Open Access Journals (Sweden)

    Sakae Meguro

    2016-05-01

    Full Text Available An observation system of centimeter-order of view of magnetic domain with local magnetization direction was developed by designing a telecentric optical system of finite design through the extension of microscope technology. The field of view realized in the developed system was 1.40 × 1.05 cm as suppressing defocus and distortion. Detection of the local magnetization direction has become possible by longitudinal Kerr observation from the orthogonal two directions. This system can be applied to the domain observation of rough surface samples and time resolved analysis for soft magnetic materials such as amorphous foil strips and soft magnetic thin films.

  20. A study of the HEB longitudinal dynamics

    International Nuclear Information System (INIS)

    Larson, D.J.

    1993-12-01

    A study of the High Energy Booster (HEB) longitudinal dynamics is presented. Full derivations of ramp dependent longitudinal variables are given. The formulas assume that the input magnetic field and beam longitudinal emittance are known as a function of time, and that either the rf voltage or the rf bucket area are known as a function of time. Once these three inputs are specified, the formulas can be used to calculate values for all other longitudinal dynamics variables. The formulas have been incorporated into a single computer code named ELVIRA: Evaluation of Longitudinal Variables in Relativistic Accelerators. The ELVIRA code is documented here in detail. The ELVIRA code is used under two initial longitudinal emittance assumptions to plot ramp functions for the longitudinal dynamics design of the HEB as of May 5, 1992

  1. Equilibrium helium film in the thick film limit

    International Nuclear Information System (INIS)

    Klier, J.; Schletterer, F.; Leiderer, P.; Shikin, V.

    2003-01-01

    For the thickness of a liquid or solid quantum film, like liquid helium or solid hydrogen, there exist still open questions about how the film thickness develops in certain limits. One of these is the thick film limit, i.e., the crossover from the thick film to bulk. We have performed measurements in this range using the surface plasmon resonance technique and an evaporated Ag film deposited on glass as substrate. The thickness of the adsorbed helium film is varied by changing the distance h of the bulk reservoir to the surface of the substrate. In the limiting case, when h > 0, the film thickness approaches about 100 nm following the van der Waals law in the retarded regime. The film thickness and its dependence on h is precisely determined and theoretically modeled. The equilibrium film thickness behaviour is discussed in detail. The agreement between theory and experiment is very good

  2. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  3. Film beyond boundaries: film, migrant narratives and other media Film beyond boundaries: film, migrant narratives and other media

    OpenAIRE

    Anelise Reich Corseuil

    2008-01-01

    The articles here presented are representative of the debates about the various transformational aspects of film studies, fostering the discussion about the transformations and interactions between national and international narrative forms, the interrelations between film and literature, and film with other media. The critical perspectives here presented range from an emphasis on cultural materialism, dialogism, reception theory, deconstructionism, narrative studies to film aesthetics or fil...

  4. Spin Seebeck effect and ballistic transport of quasi-acoustic magnons in room-temperature yttrium iron garnet films

    Science.gov (United States)

    Noack, Timo B.; Musiienko-Shmarova, Halyna Yu; Langner, Thomas; Heussner, Frank; Lauer, Viktor; Heinz, Björn; Bozhko, Dmytro A.; Vasyuchka, Vitaliy I.; Pomyalov, Anna; L’vov, Victor S.; Hillebrands, Burkard; Serga, Alexander A.

    2018-06-01

    We studied the transient behavior of the spin current generated by the longitudinal spin Seebeck effect (LSSE) in a set of platinum-coated yttrium iron garnet (YIG) films of different thicknesses. The LSSE was induced by means of pulsed microwave heating of the Pt layer and the spin currents were measured electrically using the inverse spin Hall effect in the same layer. We demonstrate that the time evolution of the LSSE is determined by the evolution of the thermal gradient triggering the flux of thermal magnons in the vicinity of the YIG/Pt interface. These magnons move ballistically within the YIG film with a constant group velocity, while their number decays exponentially within an effective propagation length. The ballistic flight of the magnons with energies above 20 K is a result of their almost linear dispersion law, similar to that of acoustic phonons. By fitting the time-dependent LSSE signal for different film thicknesses varying by almost an order of magnitude, we found that the effective propagation length is practically independent of the YIG film thickness. We consider this fact as strong support of a ballistic transport scenario—the ballistic propagation of quasi-acoustic magnons in room temperature YIG.

  5. Simulation and fabrication of 0-3 composite PZT films for ultrahigh frequency (100-300 MHz) ultrasonic transducers

    Science.gov (United States)

    Chen, Xiaoyang; Fei, Chunlong; Chen, Zeyu; Chen, Ruimin; Yu, Ping; Chen, Zhongping; Shung, K. Kirk; Zhou, Qifa

    2016-03-01

    This paper presents simulation, fabrication, and characterization of single-element ultrahigh frequency (100-300-MHz) needle ultrasonic transducers based on 0-3 composite Pb(Zr0.52Ti0.48)O3 (PZT) films prepared by using composite ceramic sol-gel film and sol-infiltration technique. The center frequency of the developed transducer at 300-MHz was the highest frequency of PbTiO3 ceramic-based ultrasonic transducers ever reported. Furthermore, a brief description of the composite model was followed by the development of a new expression for predicting the longitudinal velocity, the clamped dielectric constant, and the complex electromechanical coupling coefficient kt of these films, which is very important in ultrasonic transducer design. Moreover, these parameters are difficult to obtain by measuring the frequency dependence of impedance and phase angle because of the weak signal of the previous 0-3 composite films transducer (>100 MHz). The modeling results show that the Cubes model with a geometric factor n = 0.05 fits well with the measured data. This model will be helpful for developing the 0-3 composite systems for ultrahigh frequency ultrasonic transducer design.

  6. Bisphenol diglycidyl ethers and bisphenol A and their hydrolysis in drinking water.

    Science.gov (United States)

    Lane, R F; Adams, C D; Randtke, S J; Carter, R E

    2015-04-01

    Epoxy coatings are commonly used to protect the interior (and exterior) surfaces of water mains and storage tanks and can be used on the interior surfaces of water pipes in homes, hospitals, hotels, and other buildings. Common major components of epoxies include bisphenols, such as bisphenol A (BPA) or bisphenol F (BPF), and their reactive prepolymers, bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE), respectively. There currently are health concerns about the safety of BPA and BPF due to known estrogenic effects. Determination of key bisphenol leachates, development of a hydrolysis model, and identification of stable hydrolysis products will aid in assessment of human bisphenol exposure through ingestion of drinking water. Liquid chromatography/mass spectrometry (LC/MS/MS) was used for quantitation of key analytes, and a pseudo-first order kinetic approach was used for modeling. In fill-and-dump studies on epoxy-coated pipe specimens, BADGE and a BPA-like compound were identified as leachates. The BADGE hydrolysis model predicts BADGE half-lives at pH 7 and 15, 25, 35, and 40 °C to be 11, 4.6, 2.0, and 1.4 days respectively; the BFDGE half-life was 5 days at pH 7 and 25 °C. The two identified BADGE hydrolysis products are BADGE-H2O and BADGE 2H2O, with BADGE 2H2O being the final end product under the conditions studied. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Application of Discharges in Vapor of Evaporated Metals for the Film Deposition from the Ionized Stream

    International Nuclear Information System (INIS)

    Kostin, E.G.

    2006-01-01

    results of researches of the discharge device for ionization of the vapor of solid materials are presented. Evaporation of a material was made by an electron gun with a deviation of a beam on 180 degree. Diode type discharge device for ionization was placed above a surface of evaporated metal and was in a longitudinal adjustable magnetic field. Discharge was carried out in crossed electric and magnetic fields. Partial ionization of the vapor was made by primary and secondary electrons of the gun in a vapor cloud above evaporated substance. Physical properties and structure of the films. The comparative analysis of the films properties, besieged in conditions of influence of bombardment by ions of evaporated metal were studied depending on energy and the contents of ions in a stream of particles on a substrate

  8. Investigation of room temperature UV emission of ZnO films with different defect densities induced by laser irradiation.

    Science.gov (United States)

    Zhao, Yan; Jiang, Yijian

    2010-08-01

    We studied the room temperature UV emission of ZnO films with different defect densities which is fabricated by KrF laser irradiation process. It is shown room temperature UV photoluminescence of ZnO film is composed of contribution from free-exciton (FX) recombination and its longitudinal-optical phonon replica (FX-LO) (1LO, 2LO). With increase of the defect density, the FX emission decreased and FX-LO emission increased dramatically; and the relative strengths of FX to FX-LO emission intensities determine the peak position and intensity of UV emission. What is more, laser irradiation with moderate energy density could induce the crystalline ZnO film with very flat and smooth surface. This investigation indicates that KrF laser irradiation could effectively modulate the exciton emission and surface morphology, which is important for the application of high performance of UV emitting optoelectronic devices. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Mode and polarization state selected guided wave spectroscopy of orientational anisotrophy in model membrane cellulosic polymer films: relevance to lab-on-a-chip

    Science.gov (United States)

    Andrews, Mark P.; Kanigan, Tanya

    2007-06-01

    Orientation anisotropies in structural properties relevant to the use of cellulosic polymers as membranes for lab-on-chips were investigated for cellulose acetate (CA) and regenerated cellulose (RC) films deposited as slab waveguides. Anisotropy was probed with mode and polarization state selected guided wave Raman spectroscopy. CA exhibits partial chain orientation in the plane of the film, and this orientation is independent of sample substrate and film preparation conditions. RC films also show in-plane anisotropy, where the hexose sugar rings lie roughly in the plane of the film. Explanations are given of the role of artifacts in interpreting waveguide Raman spectra, including anomalous contributions to Raman spectra that arise from deviations from right angle scattering geometry, mode-dependent contributions to longitudinal electric field components and TETM mode conversion. We explore diffusion profiles of small molecules in cellulosic films by adaptations of an inverse-Wentzel-Kramers-Brillouin (iWKB) recursive, noninteger virtual mode index algorithm. Perturbations in the refractive index distribution, n(z), are recovered from the measured relative propagation constants, neffective,m, of the planar waveguide. The refractive index distribution then yields the diffusion profile.

  10. On Longitudinal Spectral Coherence

    DEFF Research Database (Denmark)

    Kristensen, Leif

    1979-01-01

    It is demonstrated that the longitudinal spectral coherence differs significantly from the transversal spectral coherence in its dependence on displacement and frequency. An expression for the longitudinal coherence is derived and it is shown how the scale of turbulence, the displacement between ...... observation sites and the turbulence intensity influence the results. The limitations of the theory are discussed....

  11. Longitudinal Research with Latent Variables

    CERN Document Server

    van Montfort, Kees; Satorra, Albert

    2010-01-01

    This book combines longitudinal research and latent variable research, i.e. it explains how longitudinal studies with objectives formulated in terms of latent variables should be carried out, with an emphasis on detailing how the methods are applied. Because longitudinal research with latent variables currently utilizes different approaches with different histories, different types of research questions, and different computer programs to perform the analysis, the book is divided into nine chapters. Starting from some background information about the specific approach, short history and the ma

  12. Studying gas-sheared liquid film in horizontal rectangular duct with laser-induced fluorescence technique

    Science.gov (United States)

    Cherdantsev, Andrey; Hann, David; Azzopardi, Barry

    2013-11-01

    High-speed LIF-technique is applied to study gas-sheared liquid film in horizontal rectangular duct with 161 mm width. Instantaneous distributions of film thickness resolved in both longitudinal and transverse coordinates were obtained with a frequency of 10 kHz and spatial resolution from 0.125 mm to 0.04 mm. Processes of generation of fast and slow ripples by disturbance waves are the same as described in literature for downwards annular pipe flow. Disturbance waves are often localized by transverse coordinate and may have curved or slanted fronts. Fast ripples, covering disturbance waves, are typically horseshoe-shaped and placed in staggered order. Their characteristic transverse size is of order 1 cm and it decreases with gas velocity. Entrainment of liquid from film surface can also be visualized. Mechanisms of ripple disruption, known as ``bag break-up'' and ``ligament break-up,'' were observed. Both mechanisms may occur on the same disturbance waves. Various scenarios of droplet deposition on the liquid film are observed, including the impact, slow sinking and bouncing, characterized by different outcome of secondary droplets or entrapped bubbles. Number and size of bubbles increase greatly inside the disturbance waves. Both quantities increase with gas and liquid flow rates. EPSRC Programme Grant MEMPHIS (EP/K003976/1), and Roll-Royce UTC (Nottingham, for access to flow facility).

  13. Lasing of a Solid-State Active Element Based on Anodized Aluminum Oxide Film Doped with Rhodamine 6G

    Science.gov (United States)

    Shelkovnikov, V. V.; Lyubas, G. A.; Korotaev, S. V.; Kopylova, T. N.; Tel'minov, E. N.; Gadirov, R. M.; Nikonova, E. N.; Nikonov, S. Yu.; Solodova, T. A.; Novikov, V. A.

    2017-04-01

    Spectral-luminescent and lasing characteristics of rhodamine 6G in porous aluminum oxide films anodized under various conditions are investigated. Lasing is obtained without external resonator in the longitudinal scheme under excitation by the second harmonic of Nd3+:YAG-laser radiation. The threshold pump power densities are in the range 3.5-15 MW/cm2 depending on the anodizing conditions. Wherein, the lasing line narrows down from 12 to 5 nm.

  14. Longitudinal joint specifications and performance.

    Science.gov (United States)

    2012-08-01

    Deterioration of longitudinal joints is widely recognized as one of the major factors contributing to failure of asphalt pavements. Finding : ways to improve the durability of longitudinal joints will lead to improved service lives and lower life cyc...

  15. The energy-dispersive reflectometer at BESSY II: a challenge for thin film analysis

    CERN Document Server

    Pietsch, U; Geue, T; Neissendorfer, F; Brezsesinski, G; Symietz, C; Moehwald, H; Gudat, W

    2001-01-01

    Installed in 1999 the energy-dispersive reflectometer at the 13.2 bending magnet employs the exponentially decaying white X-ray emission spectrum of the 1.7 GeV storage ring of BESSY II outside the vacuum. Using an energy-dispersive detector specular and longitudinal-diffuse reflectivity spectra of thin films can be recorded simultaneously between 0.2 A sup - sup 1 films at room temperature and its change during annealing. At T=70 deg. C we observe an instantaneous decay of specular Bragg peaks accompanied with an increase of the diffuse scattering. This indicates the onset of the melting of 2D-ordered acid domains. The vertical diffusion coefficient is estimated to be about 2x10 sup - sup 2 sup 4 m sup 2 /s.

  16. Transversely Excited Multipass Photoacoustic Cell Using Electromechanical Film as Microphone

    Directory of Open Access Journals (Sweden)

    Jaakko Saarela

    2010-05-01

    Full Text Available A novel multipass photoacoustic cell with five stacked electromechanical films as a microphone has been constructed, tested and characterized. The photoacoustic cell is an open rectangular structure with two steel plates facing each other. The longitudinal acoustic resonances are excited transversely in an optical multipass configuration. A detection limit of 22 ppb (10−9 was achieved for flowing NO2 in N2 at normal pressure by using the maximum of 70 laser beams between the resonator plates. The corresponding minimum detectable absorption and the normalized noise-equivalent absorption coefficients were 2:2 × 10−7 cm−1 and 3:2 × 10−9 cm−1WHz−1/2, respectively.

  17. Evaluation of longitudinal loading of tank trains during motion in longitudinal changes of gradient

    Directory of Open Access Journals (Sweden)

    S.V. Myamlin

    2013-06-01

    Full Text Available Purpose. To research the tank train longitudinal loading during motion by track sections with changes of gradient. The trains of different length that consist of bogie tank wagons should be examined. Influence of cargo type on longitudinal loading of train during motion in concave section of track should be evaluated. Methodology. The level of the largest longitudinal forces was estimated by mathematical simulation. It was assumed that change of gradient is formed by two grades with baffle platforms, length 50 meters, so that the algebraic difference of limiting grades vary from 10‰ to 40‰, pitch 10‰. The initial speeds were 40, 60, 80, 100, 120 km/h. For evaluation of the longitudinal loading the regulating braking and motion "by coasting" was considered. For evaluation of buffing loads the entry to the concave gradient change of expanded train is considered, and in order to determine the quasi-static forces the compressed train is considered. Findings. As a result of calculations the dependencies of maximal longitudinal forces in the trains on the cargo type, the algebraic difference of the grades, the number of tank wagons, the initial speed, motion modes, and initial gaps condition in the train were obtained. Originality. The longitudinal loading of freight cars of different length formed by the similar bogie tank wagons with one locomotive was obtained. The locomotive is placed in the train head during motion in concave track sections with various algebraic difference of the grades "on coasting" and during the regulating braking mode. The obtained results can be used for parameters standardization of profile elevation of the track. Practical value. The obtained results show that during operation of tank trains on track sections of complex breakage the most dangerous is regulating braking of preliminary compressed trains during entering on concave parts of track. Level of the greatest buffing and quasi-static longitudinal forces is

  18. An Examination of the Association between Seeing Smoking in Films and Tobacco Use in Young Adults in the West of Scotland: Cross-Sectional Study

    Science.gov (United States)

    Hunt, Kate; Sweeting, Helen; Sargent, James; Lewars, Heather; Cin, Sonya Dal; Worth, Keilah

    2009-01-01

    The objective is to examine the association between the amount of smoking seen in films and current smoking in young adults living in the west of Scotland in the UK. Cross-sectional analyses (using multivariable logistic regression) of data collected at age 19 (2002-04) from a longitudinal cohort originally surveyed at age 11 (1994-95) were…

  19. Optical properties of Mn doped ZnO films and wires synthesized by thermal oxidation of ZnMn alloy

    Energy Technology Data Exchange (ETDEWEB)

    Sima, M., E-mail: msima@infim.ro [National Institute of Materials Physics, 105bis Atomistilor Street, 077125 Magurele (Romania); Mihut, L. [National Institute of Materials Physics, 105bis Atomistilor Street, 077125 Magurele (Romania); Vasile, E. [University “Politehnica”of Bucharest, Faculty of Applied Chemistry and Material Science, Department of Oxide Materials and Nanomaterials, No. 1-7 Gh. Polizu Street, 011061 Bucharest (Romania); Sima, Ma.; Logofatu, C. [National Institute of Materials Physics, 105bis Atomistilor Street, 077125 Magurele (Romania)

    2015-09-01

    Mn doped ZnO films and wires, having different manganese concentrations were synthesized by thermal oxidation of the corresponding ZnMn alloy films and wires electrodeposited on a gold substrate. Structural and optical properties were addressed with scanning electron microscopy, X-ray diffraction (XRD), Raman scattering and photoluminescence (PL). To estimate the manganese concentration in Mn doped ZnO films, X-ray photoelectron spectroscopy was used. XRD patterns indicate that the incorporation of Mn{sup 2+} ions into the Zn{sup 2+} site of ZnO lattice takes place. Quenching of the ZnO PL appears due to Mn{sup 2+} ions in the ZnO lattice. Moreover, a significant decrease in the green emission of ZnO is reported in the case of the Mn doped ZnO wire array with a Mn concentration of 1.45%. The wurtzite ZnO has a total of 12 phonon modes, namely, one longitudinal acoustic (LA), two transverse acoustic (TA), three longitudinal optical (LO), and six transverse optical branches. Compared to the undoped ZnO, a gradual up-shift of the Raman lines assigned to the 2LA and A{sub 1} (LO) vibrational modes, from 482 and 567 cm{sup −1} to 532 and 580 cm{sup −1}, respectively, takes place for the Mn doped ZnO films having a Mn concentration between 2 and 15%. Additionally, in the case of the Mn doped ZnO films with 7 and 15% Mn concentration, Raman spectra show the appearance and increase in the relative intensity of the ZnO Raman line assigned to the TA + LO vibrational mode in the 600–750 cm{sup −1} spectral range. For the Mn-doped ZnO wires, the presence of the Raman line peaking at 527 cm{sup −1} confirms the insertion of Mn{sup 2+} ions in ZnO lattice. - Highlights: • Mn doped ZnO films and wires grown by thermal oxidation of ZnMn alloy • Incorporation of Mn{sup 2+} ions into Zn{sup 2+} site of ZnO lattice • Appearance of a strong Raman line in the spectral range 600–800 cm{sup −1} at high Mn concentration • Compensation of the oxygen vacancy at higher

  20. Film Reviews.

    Science.gov (United States)

    Lance, Larry M.; Atwater, Lynn

    1987-01-01

    Reviews four Human Sexuality films and videos. These are: "Personal Decisions" (Planned Parenthood Federation of America, 1985); "The Touch Film" (Sterling Production, 1986); "Rethinking Rape" (Film Distribution Center, 1985); "Not A Love Story" (National Film Board of Canada, 1981). (AEM)

  1. Risk assessment of topically applied products

    DEFF Research Database (Denmark)

    Søborg, Tue; Basse, Line Hollesen; Halling-Sørensen, Bent

    2007-01-01

    The human risk of harmful substances in semisolid topical dosage forms applied topically to normal skin and broken skin, respectively, was assessed. Bisphenol A diglycidyl ether (BADGE) and three derivatives of BADGE previously quantified in aqueous cream and the UV filters 3-BC and 4-MBC were used...... as model compounds. Tolerable daily intake (TDI) values have been established for BADGE and derivatives. Endocrine disruption was chosen as endpoint for 3-BC and 4-MBC. Skin permeation of the model compounds was investigated in vitro using pig skin membranes. Tape stripping was applied to simulate broken...... parameters for estimating the risk. The immediate human risk of BADGE and derivatives in topical dosage forms was found to be low. However, local treatment of broken skin may lead to higher exposure of BADGE and derivatives compared to application to normal skin. 3-BC permeated skin at higher flux than 4-MBC...

  2. Reliability of individual doses relating to the epidemiological studies on nuclear industry workers in Japan (1). Historical changes on definition of radiation dose, historical changes on technical standards of measurement and radiation workplace

    International Nuclear Information System (INIS)

    Numakunai, Takao; Ishiguro, Hideharu; Kawada, Yasushi; Minami, Kentaro; Yoshimoto, Yasuhiko.

    1997-01-01

    Records of radiation workers collected in the Research Organization for Information of Science and Technology, concerning individual doses from 1957 to 1992 were used for epidemiological studies for obtaining the scientific information of the effect of low dose radiation. Since many changes were made on definition of radiation dose, dosimetry technology and so on during such a long time period, reliability of recorded individual doses and of their measurement should be evaluated for validation, which is the purpose of this paper. Followings were discussed and validation was made. Historical changes on standards for radiation protection: ICRP Recommendation and ICRU Report, and changes of law concerning radiation dose in Japan and of dose standards. Changes on dosimetry for radiation protection: ICRP Recommendation and working place dosimetry, trends of investigations for introduction of measured practical doses, ICRU sphere as a receptor, and introduction of measured practical doses. Characteristics of radiation field and radiation exposure: Radiation source and characteristics of radiation field; Research and development organizations for atomic power, atomic power plants, facilities for nuclear fuel, Classification of radiation works and characteristics of the exposure; BWR, PWR, GCR. Changes on the standards of individual dosemeter and on its use: method to use individual dosemeter and its installation, measurement of individual dose and Japanese Industrial Standard (JIS); Standard of the film badge for X and gamma rays, Standard of the film badge for neutron, Standard for thermoluminescence dosemeter, and changes on selection of the major apparatus and on its use. (K.H.)

  3. The Evolution of Film: Rethinking Film Studies

    OpenAIRE

    Harbord, Janet P.

    2007-01-01

    How is film changing? What does it do, and what do we do with it? This book examines the reasons why we should be studying film in the twenty-first century, connecting debates from philosophy, anthropology and new media with historical concerns of film studies.

  4. Single-layer nano-carbon film, diamond film, and diamond/nano-carbon composite film field emission performance comparison

    International Nuclear Information System (INIS)

    Wang, Xiaoping; Wang, Jinye; Wang, Lijun

    2016-01-01

    A series of single-layer nano-carbon (SNC) films, diamond films, and diamond/nano-carbon (D/NC) composite films have been prepared on the highly doped silicon substrate by using microwave plasma chemical vapor deposition techniques. The films were characterised by scanning electron microscopy, Raman spectroscopy, and field emission I-V measurements. The experimental results indicated that the field emission maximum current density of D/NC composite films is 11.8–17.8 times that of diamond films. And the field emission current density of D/NC composite films is 2.9–5 times that of SNC films at an electric field of 3.0 V/μm. At the same time, the D/NC composite film exhibits the advantage of improved reproducibility and long term stability (both of the nano-carbon film within the D/NC composite cathode and the SNC cathode were prepared under the same experimental conditions). And for the D/NC composite sample, a high current density of 10 mA/cm"2 at an electric field of 3.0 V/μm was obtained. Diamond layer can effectively improve the field emission characteristics of nano-carbon film. The reason may be due to the diamond film acts as the electron acceleration layer.

  5. Fabrication and characterization of thick-film piezoelectric lead zirconate titanate ceramic resonators by tape-casting.

    Science.gov (United States)

    Qin, Lifeng; Sun, Yingying; Wang, Qing-Ming; Zhong, Youliang; Ou, Ming; Jiang, Zhishui; Tian, Wei

    2012-12-01

    In this paper, thick-film piezoelectric lead zirconate titanate (PZT) ceramic resonators with thicknesses down to tens of micrometers have been fabricated by tape-casting processing. PZT ceramic resonators with composition near the morphotropic phase boundary and with different dopants added were prepared for piezoelectric transducer applications. Material property characterization for these thick-film PZT resonators is essential for device design and applications. For the property characterization, a recently developed normalized electrical impedance spectrum method was used to determine the electromechanical coefficient and the complex piezoelectric, elastic, and dielectric coefficients from the electrical measurement of resonators using thick films. In this work, nine PZT thick-film resonators have been fabricated and characterized, and two different types of resonators, namely thickness longitudinal and transverse modes, were used for material property characterization. The results were compared with those determined by the IEEE standard method, and they agreed well. It was found that depending on the PZT formulation and dopants, the relative permittivities ε(T)(33)/ε(0) measured at 2 kHz for these thick-films are in the range of 1527 to 4829, piezoelectric stress constants (e(33) in the range of 15 to 26 C/m(2), piezoelectric strain constants (d(31)) in the range of -169 × 10(-12) C/N to -314 × 10(-12) C/N, electromechanical coupling coefficients (k(t)) in the range of 0.48 to 0.53, and k(31) in the range of 0.35 to 0.38. The characterization results shows tape-casting processing can be used to fabricate high-quality PZT thick-film resonators, and the extracted material constants can be used to for device design and application.

  6. Process and apparatus for irradiating film, and irradiated film

    International Nuclear Information System (INIS)

    1981-01-01

    A process for irradiating film is described, which consists of passing the film through an electron irradiation zone having an electron reflection surface disposed behind and generally parallel to the film; and disposing within the irradiation zone adjacent the edges of the film a lateral reflection member for reflecting the electrons toward the reflection surface to further reflect the reflected electrons towards the adjacent edges of the film. (author)

  7. Improved longitudinal magneto-optic Kerr effect signal contrast from nanomagnets with dielectric coatings

    Science.gov (United States)

    Holiday, L. F.; Gibson, U. J.

    2006-12-01

    We report on the use of dielectric coatings to improve the contrast of longitudinal magneto-optic Kerr effect signals from submicron magnetic structures. Electron-beam lithography was used to define disks in 22 nm thick Ni films deposited on Si substrates. The structures were measured in four configurations: as-deposited, through a fused silica prism using index-matching fluid, coated with ZnS, and using a prism on top of the ZnS layer. The modified samples show up to 20 times improvement in the MOKE contrast due to admittance matching to the magnetic material and suppression of the substrate reflectance. The behavior is successfully predicted by a model that includes the magneto-optic response of the nickel layer and accounts for the fraction of the beam intercepted by the magnetic structure.

  8. Longitudinal Space Charge in the SPS

    CERN Document Server

    Lasheen, Alexandre

    2016-01-01

    Longitudinal instabilities due to the SPS beam coupling impedance are a major issue for future projects and it is essential to have an accurate SPS impedance model to study them. The longitudinal space charge effect can be modelled by a pure reactive impedance and should also be included in simulations as it may have an impact at low energy. In this Note, the effect of the longitudinal space charge in the SPS is evaluated by taking into account the variation of the transverse beam size and vacuum chamber geometry along the ring. Scaling laws are used to investigate what are the most important parameters for the evaluation of the longitudinal space charge impedance.

  9. Cross-Sectional Analysis of Longitudinal Mediation Processes.

    Science.gov (United States)

    O'Laughlin, Kristine D; Martin, Monica J; Ferrer, Emilio

    2018-01-01

    Statistical mediation analysis can help to identify and explain the mechanisms behind psychological processes. Examining a set of variables for mediation effects is a ubiquitous process in the social sciences literature; however, despite evidence suggesting that cross-sectional data can misrepresent the mediation of longitudinal processes, cross-sectional analyses continue to be used in this manner. Alternative longitudinal mediation models, including those rooted in a structural equation modeling framework (cross-lagged panel, latent growth curve, and latent difference score models) are currently available and may provide a better representation of mediation processes for longitudinal data. The purpose of this paper is twofold: first, we provide a comparison of cross-sectional and longitudinal mediation models; second, we advocate using models to evaluate mediation effects that capture the temporal sequence of the process under study. Two separate empirical examples are presented to illustrate differences in the conclusions drawn from cross-sectional and longitudinal mediation analyses. Findings from these examples yielded substantial differences in interpretations between the cross-sectional and longitudinal mediation models considered here. Based on these observations, researchers should use caution when attempting to use cross-sectional data in place of longitudinal data for mediation analyses.

  10. Leukemia among participants in military maneuvers at a nuclear bomb test

    International Nuclear Information System (INIS)

    Caldwell, G.G.; Kelley, D.B.; Heath, C.W.

    1980-01-01

    To test the possibility of a casual relationship between leukemia and exposure to nuclear radiation, the frequency of leukemia in personnel observing the detonation of a nuclear device called ''Smoky'' during August 1957 was determined. Of some 3224 men who witnessed the detonation, nine cases of leukemia were observed. They included four cases of acute myelocytic leukemia, three of chronic myelocytic leukemia, one of hairy cell lymphocyctic leukemia, and one of acute lymphocytic luekemia. These findings represent a significant increase over the expected leukemia incidence of 3.5 cases. Mean film-badge gamma radiation dose for the study group was 466.2 mrem

  11. Radiation exposure of uranium mill workers

    International Nuclear Information System (INIS)

    Jha, Giridhar; Saha, S.C.

    1982-01-01

    The uranium mill workers at Jaduguda were covered by a regular film badge service from 1969 onwards. Since the log normal plot is useful in interpreting occupational exposure, a statistical analysis of the radiation exposure data was attempted. Exposure data for each year has been plotted as cumulative percentage and worker's population with exposure levels in different class intervals. The plot for each of the year under investigation shows an occupational exposure distribution more or less consistent with the log normal distribution function. The analysis shows that more than 98% of radiation workers received less than 200 mrem (2 mSv). (author)

  12. Brillouin light scattering studies on the mechanical properties of ultrathin, porous low-K dielectric films

    Science.gov (United States)

    Zhou, Wei; Sooryakumar, R.; King, Sean

    2010-03-01

    Low K dielectrics have predominantly replaced silicon dioxide as the interlayer dielectric material for interconnects in state of the art integrated circuits. To further reduce interconnect resistance-capacitance (RC) delays, additional reductions in the K for these low-K materials is being pursued by the introduction of controlled levels of porosity. The main challenge for porous low-K dielectrics is the substantial reduction in mechanical properties that is accompanied by the increased pore volume content needed to reduce K. We report on the application of the nondestructive Brillouin light scattering technique to monitor and characterize the mechanical properties of these porous films at thicknesses well below 200 nm that are pertinent to present applications. Observation of longitudinal and transverse standing wave acoustic resonances and the dispersion that accompany their transformation into traveling waves with finite in-plane wave vectors provides for the principal elastic constants that completely characterize the mechanical properties of these porous films. The mode amplitudes of the standing waves, their variation within the film, and the calculated Brillouin intensities account for most aspects of the spectra. The resulting elastic constants are compared with corresponding values obtained from other experimental techniques.

  13. Film and History.

    Science.gov (United States)

    Schaber, Robin L.

    2002-01-01

    Provides an annotated bibliography of Web sites that focus on using film to teach history. Includes Web sites in five areas: (1) film and education; (2) history of cinema; (3) film and history resources; (4) film and women; and (5) film organizations. (CMK)

  14. Gold nanorods-silicone hybrid material films and their optical limiting property

    Science.gov (United States)

    Li, Chunfang; Qi, Yanhai; Hao, Xiongwen; Peng, Xue; Li, Dongxiang

    2015-10-01

    As a kind of new optical limiting materials, gold nanoparticles have optical limiting property owing to their optical nonlinearities induced by surface plasmon resonance (SPR). Gold nanorods (GNRs) possess transversal SPR absorption and tunable longitudinal SPR absorption in the visible and near-infrared region, so they can be used as potential optical limiting materials against tunable laser pulses. In this letter, GNRs were prepared using seed-mediated growth method and surface-modified by silica coating to obtain good dispersion in polydimethylsiloxane prepolymers. Then the silicone rubber films doped with GNRs were prepared after vulcanization, whose optical limiting property and optical nonlinearity were investigated. The silicone rubber samples doped with more GNRs were found to exhibit better optical limiting performance.

  15. Extremely secure identification documents

    International Nuclear Information System (INIS)

    Tolk, K.M.; Bell, M.

    1997-09-01

    The technology developed in this project uses biometric information printed on the document and public key cryptography to ensure that an adversary cannot issue identification documents to unauthorized individuals or alter existing documents to allow their use by unauthorized individuals. This process can be used to produce many types of identification documents with much higher security than any currently in use. The system is demonstrated using a security badge as an example. This project focused on the technologies requiring development in order to make the approach viable with existing badge printing and laminating technologies. By far the most difficult was the image processing required to verify that the picture on the badge had not been altered. Another area that required considerable work was the high density printed data storage required to get sufficient data on the badge for verification of the picture. The image processing process was successfully tested, and recommendations are included to refine the badge system to ensure high reliability. A two dimensional data array suitable for printing the required data on the badge was proposed, but testing of the readability of the array had to be abandoned due to reallocation of the budgeted funds by the LDRD office

  16. Tests with films and film-screens using grid-mammography

    International Nuclear Information System (INIS)

    Wolf, G.; Kallinger, G.

    1982-01-01

    A comparison was made between mammography using grid-technique with a film-screen-system and mammography without grid, and with film-screens and also using industrial films. The image-quality of grid mammography looks like the same than using conventional techniques and industrial films. The problem of soft tissue grid techniques lies in the dose requirements, which was more than using film-screen-techniques without grid. New and improved recording systems, which reduce radiation dose when using the grid technique were analyzed. (orig.) [de

  17. Contemporary Films' Mini Course on Film Study.

    Science.gov (United States)

    Schillaci, Peter

    This minicourse on film study can be a unit in English, in arts, or in the humanities. It can help to launch a film study course or complement an introduction to theater. Whatever form it takes, it helps to build a bridge to the student's media environment. Part one, the language of images, utilizes four films which demonstrate the basic elements…

  18. Proximity credentials: A survey

    International Nuclear Information System (INIS)

    Wright, L.J.

    1987-04-01

    Credentials as a means of identifying individuals have traditionally been a photo badge and more recently, the coded credential. Another type of badge, the proximity credential, is making inroads in the personnel identification field. This badge can be read from a distance instead of being veiewed by a guard or inserted into a reading device. This report reviews proximity credentials, identifies the companies marketing or developing proximity credentials, and describes their respective credentials. 3 tabs

  19. Longitudinal dynamics of laser-cooled fast ion beams

    DEFF Research Database (Denmark)

    Weidemüller, M.; Eike, B.; Eisenbarth, U.

    1999-01-01

    We present recent results of our experiments on laser cooling of fast stored ion beams at the Heidelberg Test Storage Ring. The longitudinal motion of the ions is directly cooled by the light pressure force, whereas efficient transverse cooling is obtained indirectly by longitudinal-transverse co......We present recent results of our experiments on laser cooling of fast stored ion beams at the Heidelberg Test Storage Ring. The longitudinal motion of the ions is directly cooled by the light pressure force, whereas efficient transverse cooling is obtained indirectly by longitudinal....... When applying laser cooling in square-well buckets over long time intervals, hard Coulomb collisions suddenly disappear and the longitudinal temperature drops by about a factor of three. The observed longitudinal behaviour of the beam shows strong resemblance with the transition to an Coulomb...

  20. Longitudinal beam dynamics at transition crossing

    Energy Technology Data Exchange (ETDEWEB)

    Bogacz, S.A.

    1991-11-01

    A brief outline of the longitudinal single particle dynamics at transition is presented in terms of phase-space mappings. Simple quantitative prediction about the phase-space dilution is made. More realistic simulation (ESME) of the transition crossing is carried out (including various collective and single particle effects contributing to the longitudinal emittance blow up). The simulation takes into account the longitudinal space-charge force (bunch length oscillation), the transverse space-charge (the Umstaetter effect) and finally the dispersion of the momentum compaction factor (the Johnsen effect). As a result of this simulation one can separate relative strengths of the above mechanisms and study their individual effects on the longitudinal phase-space evolution, especially filamentation of the bunch and formation of a galaxy-like'' pattern. 7 refs., 2 figs.

  1. Loading Conditions and Longitudinal Strength

    DEFF Research Database (Denmark)

    Sørensen, Herman

    1995-01-01

    Methods for the calculation of the lightweight of the ship.Loading conditions satisfying draught, trim and intact stability requirements and analysis of the corresponding stillwater longitudinal strength.......Methods for the calculation of the lightweight of the ship.Loading conditions satisfying draught, trim and intact stability requirements and analysis of the corresponding stillwater longitudinal strength....

  2. Anomalous Hall effect in ion-beam sputtered Co2FeAl full Heusler alloy thin films

    Science.gov (United States)

    Husain, Sajid; Kumar, Ankit; Akansel, Serkan; Svedlindh, Peter; Chaudhary, Sujeet

    2017-11-01

    Investigations of temperature dependent anomalous Hall effect and longitudinal resistivity in Co2FeAl (CFA) thin films grown on Si(1 0 0) at different substrate temperature Ts are reported. The scaling of the anomalous Hall conductivity (AHC) and the associated phenomenological mechanisms (intrinsic and extrinsic) are analyzed vis-à-vis influence of Ts. The intrinsic contribution to AHC is found to be dominating over the extrinsic one. The appearance of a resistivity minimum at low temperature necessitates the inclusion of quantum corrections on account of weak localization and electron-electron scattering effects whose strength reduces with increase in Ts. The study establishes that the optimization of Ts plays an important role in the improvement of atomic ordering which indicates the higher strength of spin-orbit coupling and leads to the dominant intrinsic contribution to AHC in these CFA full Heusler alloy thin films.

  3. Strategy Selection of Film Irradiation by Accelerated ^{40}Ar^{8+} Ions for Manufacturing of Track Membranes

    CERN Document Server

    Denisov, Yu N; Kalinichenko, V V; Karamysheva, G A; Fedorenko, S B

    2004-01-01

    The industrial cyclotron CYTRACK is dedicated to the production of the track membranes. It is the basic instrument for the industry of membrane products to be consumed in medicine, biotechnology, pharmacology, microelectronics and many other industries. The cyclotron CYTRACK started working in the August of 2002. Argon ions were accelerated to a project energy of 2.4 MeV/nucleon, the extracted beam intensity was about 200 nA, the extraction efficiency totaled \\sim 50 %. In starting up operation the film was exposed in various controlled ways to charged particles with a view to achieving the values of parameters required for production of "Rosa" membranous plasmafilters. The pore uniformity in transverse direction was provided by beam scanning with a scanning magnet voltage of 73 V, the one in the longitudinal direction was provided by constancy of the film motion rate and stability of beam intensity during all the time of exposition.

  4. Polyether ether ketone film. Polyether ether ketone film

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, S. (Sumitomo Chemical Co. Ltd., Tokyo (Japan))

    1990-07-05

    The characteristics and the film making process of polyether ether ketone (PEEK) resin, and the characteristics and the applications of PEEK film, are described. PEEK is aromatic polyketone with super thermal resistance. Though it is a crystalline polymer of which the crystallinity is controlled to 48% in a highest degree, it has also amorphous property, thus it shows unique property. The characteristics of PEEK resin are found in thermal resistance, incombusti-bility, transparency, chemical resistance, light resistance and radiation resistance. As for the film making process, casting method by T-die is generally adopted. The general properties of PEEK film are excellent in high thermal resistance, good electrical properties, chemical resistance, hydrolysis resistance, radiation resistance and imcombusti-bility. In the application of PEEK film, new development is expected in following fields; a high performance composite, flexible print substrate with high thermal resistance, insulating tape with thermal resistance, and a general film in the nuclear energy industry. 5 figs., 5 tabs.

  5. Film “Darah dan Do’a” Sebagai Wacana Film Nasional Indonesia

    Directory of Open Access Journals (Sweden)

    Arda - Muhlisiun

    2016-09-01

    Abstract A national filmsuggestived towards the ideasof nationalidentity. It can be labelled ‘national’ because the representation of national identity pertains to it. Usmar Ismail’s film was described as a national film because it presents genuine Indonesian. Through the textual analysis that discursive-performative understanding of national films can be achieved; an understanding that has become a myth in context to Usmar Ismail’s film.In order to clarified concepts of national film as well as to illustrate the discourse of national films in Usmar Ismail’s work, this analysis used JinHee Choi’s theory of national cinema. In which national film was theorized based on territorial, functional and relational factors. The findings of this analysis showed how the concept of national film in Usmar Ismail’s film actually struggles against the dominant discourse of its time particularly in terms of Usmar Ismail’s figure as a determining factor in establishing national films in Indonesia.   Keyword : National Cinema, Usmar Ismail, Darah dan Doa

  6. American Film Genres: Approaches to a Critical Theory of Popular Film.

    Science.gov (United States)

    Kaminsky, Stuart M.

    This book is divided into twelve sections and contains photographs from many of the films discussed. The introduction defines film genre and describes the general theories behind this book; "The Individual Film" analyzes the film "Little Caesar" as it relates to the genre of gangster films; "Comparative Forms"…

  7. Film beyond boundaries: film, migrant narratives and other media

    OpenAIRE

    Anelise Reich Corseuil

    2006-01-01

    The articles here presented are representative of the debates about the various transformational aspects of film studies, fostering the discussion about the transformations and interactions between national and international narrative forms, the interrelations between film and literature, and film with other media. The critical perspectives here presented range from an emphasis on cultural materialism, dialogism, reception theory, deconstructionism, narrative studies to film aesthetics or fil...

  8. Longitudinal research and data collection in primary care.

    NARCIS (Netherlands)

    Weel, C. van

    2005-01-01

    PURPOSE: This article reviews examples of and experience with longitudinal research in family medicine. The objective is to use this empirical information to formulate recommendations for improving longitudinal research. METHODS: The article discusses 3 longitudinal studies from the Nijmegen

  9. Film: An Introduction.

    Science.gov (United States)

    Fell, John L.

    "Understanding Film," the opening section of this book, discusses perceptions of and responses to film and the way in which experiences with and knowledge of other media affect film viewing. The second section, "Film Elements," analyzes the basic elements of film: the use of space and time, the impact of editing, sound and color, and the effects…

  10. Screen-film mammography

    International Nuclear Information System (INIS)

    Logan, W.W.; Janus, J.A.

    1987-01-01

    The development of screen-film mammography has resulted in the re-emergence of confidence, rather than fear, in mammography. When screen-film mammography is performed with state-of-the-art dedicated equipment utilizing vigorous breast compression and a ''soft'' x-ray beam for improved contrast, screen-film images are equivalent or superior to those of reduced-dose xeromammography and superior to those of nonscreen film mammography. Technological aids for conversion from xeromammographic or nonscreen film mammographic techniques to screen-film techniques have been described. Screen-film mammography should not be attempted until dedicated equipment has been obtained and the importance of vigorous compression has been understood

  11. Computed tomography scan optimization using head phantom and radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P., E-mail: lorena.cfernandes@hotmail.com, E-mail: carlosvelcab@hotmail.com, E-mail: pridili@gmail.com, E-mail: apmourao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro de Imagem Molecular do INCT-Medicina Molecular (CIMol/UFMG) Belo Horizonte (Brazil); Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte (Brazil)

    2017-11-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  12. Computed tomography scan optimization using head phantom and radiochromic films

    International Nuclear Information System (INIS)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P.

    2017-01-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  13. Thin films

    International Nuclear Information System (INIS)

    Strongin, M.; Miller, D.L.

    1976-01-01

    This article reviews the phenomena that occur in films from the point of view of a solid state physicist. Films form the basis for many established and developing technologies. Metal layers have always been important for optical coatings and as protective coatings. In the most sophisticated cases, films and their interaction on silicon surfaces form the basis of modern electronic technology. Films of silicon, GaAs and composites of these materials promise to lead to practical photovoltaic devices

  14. The impact of viscosity on the combined heat, mass and momentum transfer in laminar liquid falling films

    Science.gov (United States)

    Mittermaier, M.; Ziegler, F.

    2018-04-01

    In this article we present a model describing a laminar film flow over a vertical isothermal plate whilst heat and mass transfer is occurring. We focus on a formulation where most common assumptions, such as constant property data and constant film thickness, have been cancelled. The hydrodynamic model results in longitudinal and transversal velocity components and their evolution in the entrance region. Heat and mass transfer occurs simultaneously and is modelled with respect to release of differential heat of solution as well as heat flow due to interdiffusion. The numerical solution is obtained by utilising a Newton-Raphson method to solve the finite difference formulation of the governing equations. Mass transfer across the film affects the development of both longitudinal and transversal velocity components. The hydrodynamics are modelled using a boundary layer approximation of the Navier-Stokes equations. The significance of simplifications on the hydrodynamic model are illustrated and discussed using a fully developed velocity profile (Nusselt flow) and a plug flow at the inlet for comparison. Even if a Nusselt profile is assumed, it develops further since mass is absorbed or desorbed. It is found that the onset of absorption occurs at shorter flow length when applying a plug flow at the inlet. If the film is initially in equilibrium, this results in a 9.3% increase in absorbed mass over a length of 0.03 m as compared with the Nusselt flow. A fluid with a viscosity five times the one of lithium bromide solution but sharing comparable properties apart from that, leads to lower overall heat and mass transfer rates. If the respective fluids are saturated at the inlet, the accumulated mass flux absorbed by lithium bromide solution is 2.2 times higher than the one absorbed by a high viscous fluid. However, when a plug flow is applied and the fluid is sub-cooled, ab initio the absorbed mass flux is slightly higher for a high viscous fluid. Assuming a sub

  15. 46 CFR 154.176 - Longitudinal contiguous hull structure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Longitudinal contiguous hull structure. 154.176 Section... Equipment Hull Structure § 154.176 Longitudinal contiguous hull structure. (a) The longitudinal contiguous hull structure of a vessel having cargo containment systems without secondary barriers must meet the...

  16. Film som kunst

    DEFF Research Database (Denmark)

    Petersen, Anne Ring

    2013-01-01

    Films by artists induce scholars to work across art, film and cultural history. Accordingly, this article adopts an interdisciplinary approach to the British-Nigerian artist Yinka Shonibare’s film Un Ballo in Maschera (2004). The film is grounded in Shonibare’s unique use of African-print fabric...... in conjunction with references to European cultural and political history, but the film is also – it is alleged – rooted in Black British cinema and the transnational postcolonialism which emerged in the UK of the 1980s. The article starts with a general introduction to Shonibare’s art and the colonial...... connotations of the African-print fabric, which are also central to the critique of power in Un Ballo in Maschera. Its critical agenda is then analysed and put into historical perspective by relating the film to Black British film. A comparison with the Black Audio Film Collective’s key work Handsworth Songs...

  17. Volume 10 No. 2 February 2010 2152 DETERMINATION OF ...

    African Journals Online (AJOL)

    2010-02-02

    Feb 2, 2010 ... lacquered with epoxyphenolic or organosol resins. BADGE concentrations were ... Key words: Epoxyphenolic resin, BADGE, Can, Food ..... monomers and additives used in the manufacture of plastics and coatings intended to ...

  18. Total Survey Error for Longitudinal Surveys

    NARCIS (Netherlands)

    Lynn, Peter; Lugtig, P.J.

    2016-01-01

    This article describes the application of the total survey error paradigm to longitudinal surveys. Several aspects of survey error, and of the interactions between different types of error, are distinct in the longitudinal survey context. Furthermore, error trade-off decisions in survey design and

  19. Internato Longitudinal

    Directory of Open Access Journals (Sweden)

    Marcelo Marcos Piva Demarzo

    Full Text Available O internato médico tem gerado recorrente debate frente às transformações curriculares em andamento no País. A despeito das discussões, um modelo de internato consonante com essas mudanças ainda não foi consistentemente delineado. Neste ensaio, trazemos uma proposta de matriz estruturante para o internato médico. Propomos que o internato médico seja realizado durante os seis anos do curso, de forma longitudinal, tendo como eixo estruturante a clínica da Atenção Básica (AB. Esse modelo de "internato longitudinal" prevê a introdução progressiva na prática clínica, iniciando-se pela AB nos dois primeiros anos, acrescentando-se progressivamente os ambulatórios de especialidades, os estágios hospitalares e demais atividades práticas, alcançando-se, dessa forma, o rol de diversidade e complexidade previsto para o egresso da escola médica.

  20. Longitudinal muscle dysfunction in achalasia esophagus and its relevance.

    Science.gov (United States)

    Mittal, Ravinder K; Hong, Su Jin; Bhargava, Valmik

    2013-04-01

    Muscularis propria of the esophagus is organized into circular and longitudinal muscle layers. Goal of this review is to summarize the role of longitudinal muscle in physiology and pathophysiology of esophageal sensory and motor function. Simultaneous manometry and ultrasound imaging that measure circular and longitudinal muscle contraction respectively reveal that during peristalsis 2 layers of the esophagus contract in perfect synchrony. On the other hand, during transient relaxation of the lower esophageal sphincter (LES), longitudinal muscle contracts independently of circular muscle. Recent studies provide novel insights, i.e., longitudinal muscle contraction of the esophagus induces LES relaxation and possibly descending relaxation of the esophagus. In achalasia esophagus and other motility disorders there is discoordination between the 2 muscle layers. Longitudinal muscle contraction patterns are different in the recently described three types of achalasia identified by high-resolution manometry. Robust contraction of the longitudinal muscle in type II achalasia causes pan-esophageal pressurization and is the mechanism of whatever little esophageal emptying that take place in the absence of peristalsis and impaired LES relaxation. It may be that preserved longitudinal muscle contraction is also the reason for superior outcome to medical/surgical therapy in type II achalasia esophagus. Prolonged contractions of longitudinal muscles of the esophagus is a possible mechanism of heartburn and "angina like" pain seen in esophageal motility disorders and possibly achalasia esophagus. Novel techniques to record longitudinal muscle contraction are on the horizon. Neuro-pharmacologic control of circular and longitudinal muscles is different, which provides an important opportunity for the development of novel pharmacological therapies to treat sensory and motor disorders of the esophagus.

  1. Summary of longitudinal instabilities workshop

    Energy Technology Data Exchange (ETDEWEB)

    Chasman, R.

    1976-01-01

    A five-day ISABELLE workshop on longitudinal instabilities was held at Brookhaven, August 9-13, 1976. About a dozen outside accelerator experts, both from Europe and the U.S.A., joined the local staff for discussions of longitudinal instabilities in ISABELLE. An agenda of talks was scheduled for the first day of the workshop. Later during the week, a presentation was given on the subject ''A more rigorous treatment of Landau damping in longitudinal beam instabilities''. A few progress meetings were held in which disagreements regarding calculations of coupling impedances were clarified. A summary session was held on the last day. Heavy emphasis was put on single bunched beam instabilities in the microwave region extending above the cut-off frequency of the ISABELLE vacuum chamber.

  2. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  3. Filming eugenics: teaching the history of eugenics through film.

    Science.gov (United States)

    Ooten, Melissa; Trembanis, Sarah

    2007-01-01

    In teaching eugenics to undergraduate students and general public audiences, film should he considered as a provocative and fruitful medium that can generate important discussions about the intersections among eugenics, gender, class, race, and sexuality. This paper considers the use of two films, A Bill of Divorcement and The Lynchburg Story, as pedagogical tools for the history of eugenics. The authors provide background information on the films and suggestions for using the films to foster an active engagement with the historical eugenics movement.

  4. Nuclear films

    International Nuclear Information System (INIS)

    Malone, Peter.

    1985-01-01

    This booklet is a resource for the study of feature films that highlight the theme of nuclear war. It provides basic credits and brief indication of the theme, treatment, quality and particular notable aspects; and a series of questions raised by the film. Seventy feature films and thirty documentaries are examined

  5. Small planar domains in amorphous thin films: Nucleation and equilibrium conditions (abstract)

    Science.gov (United States)

    Labrune, M.; Hamzaoui, S.; Puchalska, I. B.; Battarel, C.; Hubert, A.

    1984-03-01

    The purpose of this work is to investigate a new type of small flat domain in the shape of lozenges. Such domains may be used for high-density nonvolatile shift register memories [C. Battarel, R. Morille, and A. Caplain, IEEE Trans. Magn. July (1983)]. Experimental and theoretical results for nucleation and stability of small lozenge domains less than 10 μm in length in Co-Ni-P and CoTi [G. Suran, K. Ounadjela, and J. Sztern (this Proceedings)] amorphous thin films 1500 Å thick are presented. The films have a low coercivity (Hc ˜1 Oe) and a significant in-plane uniaxial anisotropy (HK ˜35 Oe). The domains were observed in an optical microscope by longitudinal Kerr effect using an experimental method described by Prutton. Domain nucleation is obtained by applying a local field higher than HK. It must be emphasized that to stabilize the domain two constant fields having opposite direction are required: H1 applied inside the domain and parallel to its magnetization; H2 parallel to the main magnetization of the film (H1>H2). Experimental results obtained for such configuration of magnetic fields will be presented and compared with numerical computations. The theoretical model will be discussed and the role played by the magnetostatic energy emphasized. The model takes into account the spreading of the magnetic charges which appear at the boundary of the domain. Finally, application to experimental devices as mentioned in the first reference above will be shown.

  6. Film processing

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The processing was made not only to show what are in the film but also to produce radiograph with high quality where the information gathered really presented level of the quality of the object inspected. Besides that, good procedure will make the film with good quality can keep the film in long time for reference. Here, more detailed on how the dark room functioned and its design. So, the good procedure while processed the film will be discussed detailed in this chapter from entering the dark room to exit from there.

  7. Automatic film loader for X-ray spot film device

    International Nuclear Information System (INIS)

    1975-01-01

    A light tight tunnel extends over the top of a diagnostic X-ray table. A film cassette is mounted for reciprocating in the tunnel between an X-ray exposure position and a position in which the cassette is unloaded or loaded with film automatically. Unexposed films are dispensed one at a time into the cassette from a feed magazine at one end of the tunnel. After exposure, the film is ejected from the cassette into a receiving magazine at the same end of the tunnel. (Auth.)

  8. Radiation protection in the Czechoslovak nuclear power plants

    International Nuclear Information System (INIS)

    Singer, J.; Koc, J.; Hynek, J.; Trousil, J.

    1987-01-01

    The radiation monitoring by means of the central information system and of autonomous, portable and laboratory devices as well as a brief characteristic of the nuclear power plant radiation fields are described. The new personal dosimetric film and thermoluminescent badges and the method (including the block diagram) for personal dose evaluation are also introduced. Internal contamination monitoring is performed by means of a whole-body counter and excreta sample analysis. Monitoring the influence of effluents from nuclear power plants on environment in Czechoslovakia is based on significant radionuclide measurements in ventilation stacks and in the environment, also by means of the telemetric system, all in connection with mathematical models. (author)

  9. Health of Australian atomic test personnel

    International Nuclear Information System (INIS)

    Donovan, J.

    1984-01-01

    This paper briefly summarises the results of a survey of the health of Australian personnel who took part in the U.K. atomic weapons tests between 1952 and 1957. The study identified indications of radiation exposure among participants and examined their health in relation to the answers they gave. For example, the study compared the health of those participants who said they cleaned up radioactive areas after tests with the health of those who said they had not. There was no excess of disease or death for any disease group studied in those members of the workforce who had film badge evidence of exposure to radiation

  10. Access control system for ISABELLE

    International Nuclear Information System (INIS)

    Potter, K.; Littenberg, L.

    1977-01-01

    An access system based on the one now in operation at the CERN ISR is recommended. Access doors would presumably be located at the entrances to the utility tunnels connecting the support buildings with the ring. Persons requesting access would insert an identity card into a scanner to activate the system. The request would be autologged, the keybank adjacent to the door would be unlocked and ISABELLE operations would be notified. The operator would then select the door, activating a TV-audio link. The person requesting entry would draw a key from the bank, show it and his film badge to the operator who would enable the door release

  11. Flexible structured high-frequency film bulk acoustic resonator for flexible wireless electronics

    International Nuclear Information System (INIS)

    Zhou, Changjian; Shu, Yi; Yang, Yi; Ren, Tian-Ling; Jin, Hao; Dong, Shu-Rong; Chan, Mansun

    2015-01-01

    Flexible electronics have inspired many novel and very important applications in recent years and various flexible electronic devices such as diodes, transistors, circuits, sensors, and radiofrequency (RF) passive devices including antennas and inductors have been reported. However, the lack of a high-performance RF resonator is one of the key bottlenecks to implement flexible wireless electronics. In this study, for the first time, a novel ultra-flexible structured film bulk acoustic resonator (FBAR) is proposed. The flexible FBAR is fabricated on a flexible polyimide substrate using piezoelectric thin film aluminum nitride (AlN) for acoustic wave excitation. Both the shear wave and longitudinal wave can be excited under the surface interdigital electrodes configuration we proposed. In the case of the thickness extension mode, a flexible resonator with a working frequency as high as of 5.2325 GHz has been realized. The resonators stay fully functional under bending status and after repeated bending and re-flattening operations. This flexible high-frequency resonator will serve as a key building block for the future flexible wireless electronics, greatly expanding the application scope of flexible electronics. (paper)

  12. Study of CSR longitudinal bunch compression cavity

    International Nuclear Information System (INIS)

    Yin Dayu; Li Peng; Liu Yong; Xie Qingchun

    2009-01-01

    The scheme of longitudinal bunch compression cavity for the Cooling Storage Ring (CSR)is an important issue. Plasma physics experiments require high density heavy ion beam and short pulsed bunch,which can be produced by non-adiabatic compression of bunch implemented by a fast compression with 90 degree rotation in the longitudinal phase space. The phase space rotation in fast compression is initiated by a fast jump of the RF-voltage amplitude. For this purpose, the CSR longitudinal bunch compression cavity, loaded with FINEMET-FT-1M is studied and simulated with MAFIA code. In this paper, the CSR longitudinal bunch compression cavity is simulated and the initial bunch length of 238 U 72+ with 250 MeV/u will be compressed from 200 ns to 50 ns.The construction and RF properties of the CSR longitudinal bunch compression cavity are simulated and calculated also with MAFIA code. The operation frequency of the cavity is 1.15 MHz with peak voltage of 80 kV, and the cavity can be used to compress heavy ions in the CSR. (authors)

  13. Water-evaporation reduction by duplex films: application to the human tear film.

    Science.gov (United States)

    Cerretani, Colin F; Ho, Nghia H; Radke, C J

    2013-09-01

    Water-evaporation reduction by duplex-oil films is especially important to understand the physiology of the human tear film. Secreted lipids, called meibum, form a duplex film that coats the aqueous tear film and purportedly reduces tear evaporation. Lipid-layer deficiency is correlated with the occurrence of dry-eye disease; however, in-vitro experiments fail to show water-evaporation reduction by tear-lipid duplex films. We review the available literature on water-evaporation reduction by duplex-oil films and outline the theoretical underpinnings of spreading and evaporation kinetics that govern behavior of these systems. A dissolution-diffusion model unifies the data reported in the literature and identifies dewetting of duplex films into lenses as a key challenge to obtaining significant evaporation reduction. We develop an improved apparatus for measuring evaporation reduction by duplex-oil films including simultaneous assessment of film coverage, stability, and temperature, all under controlled external mass transfer. New data reported in this study fit into the larger body of work conducted on water-evaporation reduction by duplex-oil films. Duplex-oil films of oxidized mineral oil/mucin (MOx/BSM), human meibum (HM), and bovine meibum (BM) reduce water evaporation by a dissolution-diffusion mechanism, as confirmed by agreement between measurement and theory. The water permeability of oxidized-mineral-oil duplex films agrees with those reported in the literature, after correction for the presence of mucin. We find that duplex-oil films of bovine and human meibum at physiologic temperature reduce water evaporation only 6-8% for a 100-nm film thickness pertinent to the human tear film. Comparison to in-vivo human tear-evaporation measurements is inconclusive because evaporation from a clean-water surface is not measured and because the mass-transfer resistance is not characterized. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Effect of film size on drainage of foam and emulsion films

    International Nuclear Information System (INIS)

    Malhotra, A.K.; Wasan, D.T.

    1987-01-01

    All available theoretical analyses for the drainage of thin plane-parallel liquid films, such as those existing between two approaching liquid droplets or bubbles in the coalescence process, predict essentially the same dependence of rate of thinning of the intervening film on its size as is described by the Reynolds equation - that is, drainage time increases with the square of the film radius. Recently, the authors reported experimental data for both foam and emulsion films which showed that the measured drainage times increase with about a 0.8 power of the film radius, a value much smaller than the theoretically predicted value of 2.0. Here they present a hydrodynamic analysis to predict the experimentally observed effect of film size on the kinetics of thinning of emulsion and foam films. They extend the applicability of the Reynolds model by accounting for the flow in the Plateau borders as well as the London-van der Waals forces in the thin film phase. Their theoretical predictions are in good agreement with the experimental data on the dependence of drainage time of both foam and emulsion films on their radii

  15. Occupational radiation exposure in the GDR in 1980

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1982-01-01

    As in the previous year, the centralized monitoring of radiation workers for occupational exposure was carried out on the basis of film badges (38,781 persons), measurements with a whole-body counter and analyses of biosamples (351 persons in all). According to the film data, the monthly exposures exceeding 4 mGy totalled 682 including 48 doses higher than 10 mGy. Four workers received annual doses above 50 mGy, with the highest value being 1410 mGy. For the exposed population as a whole and some sub-groups, annual collective and mean annual doses have been given. In assessing internal exposure situation, use has been made of both data from the centralized monitoring program and those determined by some nuclear facilities themselves under the auspices of the SAAS. The results gave no indication of internal doses exceeding the annual limits of intake. (author)

  16. Occupational radiation exposure in the GDR in 1979

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1982-01-01

    As in the previous year, the centralized monitoring of radiation workers for occupational exposure was carried out on the basis of film badges (38,178 persons), measurements with a whole-body counter (247 persons) and analyses of biosamples (318 persons). According to the film data, the monthly exposures exceeding 4 mGy totalled 610 including 92 doses higher than 10 mGy. Six workers received annual doses above 50 mGy, with the highest value being 123 mGy. For the exposed population as a whole and some sub-groups, annual collective and mean annual doses have been given. In assessing the internal exposure situation, use has been made of both data from the centralized monitoring program and those determined by some nuclear facilities themselves under the auspices of the SAAS. The results gave no indication of internal doses exceeding the annual limits of intake. (author)

  17. Superconducting thin films

    International Nuclear Information System (INIS)

    Hebard, A.F.; Vandenberg, J.M.

    1982-01-01

    This invention relates to granular metal and metal oxide superconducting films formed by ion beam sputter deposition. Illustratively, the films comprise irregularly shaped, randomly oriented, small lead grains interspersed in an insulating lead oxide matrix. The films are hillock-resistant when subjected to thermal cycling and exhibit unusual josephson-type switching characteristics. Depending on the oxygen content, a film may behave in a manner similar to that of a plurality of series connected josephson junctions, or the film may have a voltage difference in a direction parallel to a major surface of the film that is capable of being switched from zero voltage difference to a finite voltage difference in response to a current larger than the critical current

  18. Simultaneous maximum a posteriori longitudinal PET image reconstruction

    Science.gov (United States)

    Ellis, Sam; Reader, Andrew J.

    2017-09-01

    Positron emission tomography (PET) is frequently used to monitor functional changes that occur over extended time scales, for example in longitudinal oncology PET protocols that include routine clinical follow-up scans to assess the efficacy of a course of treatment. In these contexts PET datasets are currently reconstructed into images using single-dataset reconstruction methods. Inspired by recently proposed joint PET-MR reconstruction methods, we propose to reconstruct longitudinal datasets simultaneously by using a joint penalty term in order to exploit the high degree of similarity between longitudinal images. We achieved this by penalising voxel-wise differences between pairs of longitudinal PET images in a one-step-late maximum a posteriori (MAP) fashion, resulting in the MAP simultaneous longitudinal reconstruction (SLR) method. The proposed method reduced reconstruction errors and visually improved images relative to standard maximum likelihood expectation-maximisation (ML-EM) in simulated 2D longitudinal brain tumour scans. In reconstructions of split real 3D data with inserted simulated tumours, noise across images reconstructed with MAP-SLR was reduced to levels equivalent to doubling the number of detected counts when using ML-EM. Furthermore, quantification of tumour activities was largely preserved over a variety of longitudinal tumour changes, including changes in size and activity, with larger changes inducing larger biases relative to standard ML-EM reconstructions. Similar improvements were observed for a range of counts levels, demonstrating the robustness of the method when used with a single penalty strength. The results suggest that longitudinal regularisation is a simple but effective method of improving reconstructed PET images without using resolution degrading priors.

  19. As Film Goes Byte: The Change From Analog to Digital Film Perception

    OpenAIRE

    Loertscher, Miriam Laura; Weibel, David; Spiegel, Simon; Flueckiger, Barbara; Mennel, Pierre; Mast, Fred; Iseli, Christian

    2016-01-01

    The digital revolution changed film production in many ways. Until the end of the 20th century, most film professionals and critics preferred celluloid film. However, no previous empirical study compared complete narrative films recorded with analog and digital cinematography. Three short narrative films were produced with an analog and a digital camera attached to a 3D rig in order to control all optical parameters. In postproduction, a third version of a digital film was created to mimic th...

  20. As Film Goes Byte: The Change From Analog to Digital Film Perception.

    OpenAIRE

    Loertscher M. L. Weibel D. Spiegel S. Flueckiger B. Mennel P. Mast F. W. & Iseli C.

    2016-01-01

    The digital revolution changed film production in many ways. Until the end of the 20th century most film professionals and critics preferred celluloid film. However no previous empirical study compared complete narrative films recorded with analog and digital cinematography. Three short narrative films were produced with an analog and a digital camera attached to a 3D rig in order to control all optical parameters. In postproduction a third version of a digital film was created to mimic the a...

  1. Longitudinal single-bunch instabilities

    International Nuclear Information System (INIS)

    Migliorati, M.; Palumbo, L.; Rome Univ. La Sapienza, Rome

    2001-02-01

    After introducing the concepts of longitudinal wakefield and coupling impedance, it is reviewed the theory of longitudinal single-bunch collective effects in storage rings. From the Fokker-Planck equation it is first derived the stationary solution describing the natural single-bunch regime, and then treat the problem of microwave instability, showing the different approaches used for estimating the threshold current. The lecture is ended with the semi-empirical laws that allow everyone to obtain the single-bunch behaviour above threshold, and with a description of the simulation codes that are now reliable tools for investigating all these effects

  2. LIA longitudinal coupling impedance

    International Nuclear Information System (INIS)

    Faltens, A.

    1980-01-01

    The beam generated fields enter into the problems of waveform generation and longitudinal stability. In the former, provision must be made for the longitudinally defocusing forces due to the space charge and the beam loading effects on the accelerating voltage due to the current of a presumably known bunch. In the latter, the concern is for the growth of unintentional perturbations to unacceptably large values through the interaction of the charge and current fluctuations with the rest of the beam and the surrounding structures. These beam generated electric fields may be related to the beam current through a coupling impedance

  3. Longitudinal beam dynamics

    International Nuclear Information System (INIS)

    Tecker, F

    2014-01-01

    The course gives a summary of longitudinal beam dynamics for both linear and circular accelerators. After discussing different types of acceleration methods and synchronism conditions, it focuses on the particle motion in synchrotrons

  4. Demens Film

    DEFF Research Database (Denmark)

    Jensen, Anders Møller

    2012-01-01

    Vi vil skabe film til mennesker med demens – ikke film om demens sygdommen eller beretninger om livet og hverdagen med en kronisk lidelse. Filmene skal medvirke til at frembringe en behagelig stemning omkring og hos mennesker med demens, så hverdagen bliver så tryg som mulig. Filmene skal samtidig...... var at afgrænse og prioritere projektet, samt komme med anbefalinger omkring hvad der er vigtigt, i forbindelse med produktion af film målrettet mennesker med demens. Resultat af ekspertgruppen sammenfattes i denne rapport. Projektet gennemføres som et samarbejde mellem Retrospect Film...

  5. Ag films deposited on Si and Ti: How the film-substrate interaction influences the nanoscale film morphology

    Science.gov (United States)

    Ruffino, F.; Torrisi, V.

    2017-11-01

    Submicron-thick Ag films were sputter deposited, at room temperature, on Si, covered by the native SiO2 layer, and on Ti, covered by the native TiO2 layer, under normal and oblique deposition angle. The aim of this work was to study the morphological differences in the grown Ag films on the two substrates when fixed all the other deposition parameters. In fact, the surface diffusivity of the Ag adatoms is different on the two substrates (higher on the SiO2 surface) due to the different Ag-SiO2 and Ag-TiO2 atomic interactions. So, the effect of the adatoms surface diffusivity, as determined by the adatoms-substrate interaction, on the final film morphology was analyzed. To this end, microscopic analyses were used to study the morphology of the grown Ag films. Even if the homologous temperature prescribes that the Ag film grows on both substrates in the zone I described by the structure zone model some significant differences are observed on the basis of the supporting substrate. In the normal incidence condition, on the SiO2/Si surface a dense close-packed Ag film exhibiting a smooth surface is obtained, while on the TiO2/Ti surface a more columnar film morphology is formed. In the oblique incidence condition the columnar morphology for the Ag film occurs both on SiO2/Si and TiO2/Ti but a higher porous columnar film is obtained on TiO2/Ti due to the lower Ag diffusivity. These results indicate that the adatoms diffusivity on the substrate as determined by the adatom-surface interaction (in addition to the substrate temperature) strongly determines the final film nanostructure.

  6. Development of neutron diffuse scattering analysis code by thin film and multilayer film

    International Nuclear Information System (INIS)

    Soyama, Kazuhiko

    2004-01-01

    To research surface structure of thin film and multilayer film by neutron, a neutron diffuse scattering analysis code using DWBA (Distorted-Wave Bron Approximation) principle was developed. Subjects using this code contain the surface and interface properties of solid/solid, solid/liquid, liquid/liquid and gas/liquid, and metal, magnetism and polymer thin film and biomembran. The roughness of surface and interface of substance shows fractal self-similarity and its analytical model is based on DWBA theory by Sinha. The surface and interface properties by diffuse scattering are investigated on the basis of the theoretical model. The calculation values are proved to be agreed with the experimental values. On neutron diffuse scattering by thin film, roughness of surface of thin film, correlation function, neutron propagation by thin film, diffuse scattering by DWBA theory, measurement model, SDIFFF (neutron diffuse scattering analysis program by thin film) and simulation results are explained. On neutron diffuse scattering by multilayer film, roughness of multilayer film, principle of diffuse scattering, measurement method and simulation examples by MDIFF (neutron diffuse scattering analysis program by multilayer film) are explained. (S.Y.)To research surface structure of thin film and multilayer film by neutron, a neutron diffuse scattering analysis code using DWBA (Distorted-Wave Bron Approximation) principle was developed. Subjects using this code contain the surface and interface properties of solid/solid, solid/liquid, liquid/liquid and gas/liquid, and metal, magnetism and polymer thin film and biomembran. The roughness of surface and interface of substance shows fractal self-similarity and its analytical model is based on DWBA theory by Sinha. The surface and interface properties by diffuse scattering are investigated on the basis of the theoretical model. The calculation values are proved to be agreed with the experimental values. On neutron diffuse scattering

  7. Longitudinal Control for Mengshi Autonomous Vehicle via Cloud Model

    Science.gov (United States)

    Gao, H. B.; Zhang, X. Y.; Li, D. Y.; Liu, Y. C.

    2018-03-01

    Dynamic robustness and stability control is a requirement for self-driving of autonomous vehicle. Longitudinal control method of autonomous is a key technique which has drawn the attention of industry and academe. In this paper, we present a longitudinal control algorithm based on cloud model for Mengshi autonomous vehicle to ensure the dynamic stability and tracking performance of Mengshi autonomous vehicle. An experiments is applied to test the implementation of the longitudinal control algorithm. Empirical results show that if the longitudinal control algorithm based Gauss cloud model are applied to calculate the acceleration, and the vehicles drive at different speeds, a stable longitudinal control effect is achieved.

  8. Automation at NRCN Dosimetry Laboratory

    International Nuclear Information System (INIS)

    Abraham, A.; Arad, I.; Mesing, M.; Levinson, S.; Weinstein, M.; Pelled, O.; Broida, A.; German, U.

    2014-01-01

    Running a dosimetric service based on TLD technology such as at the Nuclear Research Centre Negev (NRCN) requires a large group of workers to carry out simple mechanical actions such as opening and closing TLD badges, placing and removal of TLD cards from the badges and operating the TLD reader. These actions can be automated to free human resources for other assignments and to improve the quality assurance. At NRCN a project was undertaken to design and build a robotic system based on a manipulator arm. The design was based on the experience achieved with an earlier prototype (1,2). The system stores the TLD badges in special designed boxes, which are transported and stored in computer defined bins. The robotic arm loads and unloads TLD cards to the badges, and loads/unloads the cards to a magazine for the TLD reader. At the Nuclear Research Center Negev (NRCN) each badge is assigned to a specific worker and bears a sticker containing the worker's personal details, also in a machine readable form (barcode). In order to establish a proper QA check, a barcode reader records the information on the badge and on the TLD card placed in this badge and checks their compatibility with the information contained in the main database. Besides the TLD cards loading/unloading station, there is a contamination check station, a cards cleaning station and a UV irradiation box used to reduce the history dependent residual dose. The system was installed at the NRCN dosimetry laboratory It was successfully tested for several hundreds of cycles and will become operational in the first quarter of 2014. As far as we know, there is no similar product available for automatic handling in a TLD laboratory

  9. Ring RF and longitudinal dynamics in the SNS

    International Nuclear Information System (INIS)

    Blaskiewicz, M.; Brennan, J.M.; Brodowski, J.; Delong, J.; Meth, M.; Onillon, E.; Zaltsman, A.

    2000-01-01

    Average beam currents of 40 A will be present in the Spallation Neutron Source. Even though the entire cycle time is only one synchrotron oscillation the longitudinal phase space determines peak beam current and momentum spread. Both factors play a role in space charge and instability dynamics. Longitudinal simulations with beam loading and longitudinal space charge have been done in the design phase

  10. Film beyond boundaries: film, migrant narratives and other media Film beyond boundaries: film, migrant narratives and other media

    Directory of Open Access Journals (Sweden)

    Anelise Reich Corseuil

    2008-04-01

    Full Text Available The articles here presented are representative of the debates about the various transformational aspects of film studies, fostering the discussion about the transformations and interactions between national and international narrative forms, the interrelations between film and literature, and film with other media. The critical perspectives here presented range from an emphasis on cultural materialism, dialogism, reception theory, deconstructionism, narrative studies to film aesthetics or film genre, and can be grouped in three major interrelated areas of film studies: adaptation studies, representation and aesthetics, and film and other media. All of them enable a critical perspective as regards the fluidity of the boundaries separating film from other media, such as literature, television, DVDs, and video games, as newer narrative forms that are incorporated by film, and the transformations in terms of aesthetics and forms of representation in contemporary film and media (the transgeneric nature of film, the interrelations between national and international cinemas, and the demands for a broader perception of the overwhelming mediations of the image in our contemporary society. Moreover, the articles are inserted within recent critical debates on adaptation, digital media and national and transnational cinema (Naremore, Sobchack, Druckery and Williams. All articles combine important theoretical concerns with the analysis of specific films. Robert Stam's “Teoria e Prática da Adaptação: da Fidelidade à Intertextualidade” (“Theory and the practice of adaptation: from fidelity to intertextuality” offers a rich perspective on the issue of adaptation in its relationship with critical theory. He analyses the changing critical views on adaptation, which go from the priority given to the canonic literary text, as an origin, to a more fluid, intertextual and dialogical approach to film adaptation. Drawing from Bakhtin's concept of

  11. Boosted Multivariate Trees for Longitudinal Data

    Science.gov (United States)

    Pande, Amol; Li, Liang; Rajeswaran, Jeevanantham; Ehrlinger, John; Kogalur, Udaya B.; Blackstone, Eugene H.; Ishwaran, Hemant

    2017-01-01

    Machine learning methods provide a powerful approach for analyzing longitudinal data in which repeated measurements are observed for a subject over time. We boost multivariate trees to fit a novel flexible semi-nonparametric marginal model for longitudinal data. In this model, features are assumed to be nonparametric, while feature-time interactions are modeled semi-nonparametrically utilizing P-splines with estimated smoothing parameter. In order to avoid overfitting, we describe a relatively simple in sample cross-validation method which can be used to estimate the optimal boosting iteration and which has the surprising added benefit of stabilizing certain parameter estimates. Our new multivariate tree boosting method is shown to be highly flexible, robust to covariance misspecification and unbalanced designs, and resistant to overfitting in high dimensions. Feature selection can be used to identify important features and feature-time interactions. An application to longitudinal data of forced 1-second lung expiratory volume (FEV1) for lung transplant patients identifies an important feature-time interaction and illustrates the ease with which our method can find complex relationships in longitudinal data. PMID:29249866

  12. Danish independent film, or how to make films without public funding

    DEFF Research Database (Denmark)

    Hansen, Kim Toft

    Studying independent film in Denmark is a new and interesting way to analyse power relations in Danish film productions. The sheer magnitude of Danish indiefilms is in itself a very convincing voice to be heard. Throughout the past almost two decades we have seen a developing challenge to the typ......Studying independent film in Denmark is a new and interesting way to analyse power relations in Danish film productions. The sheer magnitude of Danish indiefilms is in itself a very convincing voice to be heard. Throughout the past almost two decades we have seen a developing challenge...... known as – Danish independent film is the American director Robert Rodriguez and especially his book Rebel without a crew (1995). The book is a diary of his first successful feature film production El mariachi (1992) and, basically, here he outlines a very different do-it-yourself-method of film...

  13. Contributions of Film Introductions and Film Summaries to Learning from Instructional Films.

    Science.gov (United States)

    Lathrop, C. W., Jr.; Norford, C. A.

    An exploratory study of the contribution to learning of typical introductory and summarizing sequences in instructional films underlined the need for further experimental work to determine what kinds of introductory and concluding sequences are most useful in promoting learning from films. The first part of the study was concerned with film…

  14. Films and dark room

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After we know where the radiographic come from, then we must know about the film and also dark room. So, this chapter 5 discusses the two main components for radiography work that is film and dark room, places to process the film. Film are structured with three structured that are basic structured, emulsion and protection structured. So, this film can be classified either with their speed, screen and standard that used. The process to wash the film must be done in dark room otherwise the radiographer cannot get what are they inspected. The processing of film will be discussed briefly in next chapter.

  15. ANALISIS SUDUT PANDANG KAMERA (Studi kasus: Film Jelangkung dan Film The Ring 1

    Directory of Open Access Journals (Sweden)

    Listia Natadjaja

    2005-01-01

    Full Text Available Horror movie is one of the strengths of Indonesian film industry; however it is not so popular in the International market. Thus%2C an analysis is needed to determine what the strengths are of another horror movie that has achieved global recognition. This analysis trie s to examine film angles that could be one of the important factors in audio visual in creating horror movies. The Ring 1 is chosen as a comparison to Indonesian horror movie. The Ring 1 has the most world recognition%2C and it has been re-made by Korean and American horror movie makers. Jelangkung is chosen because it is the pioneer of horror movies in Indonesia and has inspired other movies in the same genre. Both films are analyzed from the camera angle aspect which gives the horror effect. Abstract in Bahasa Indonesia : Film horor merupakan salah satu kekuatan perfilman layar lebar di Indonesia.%2C akan tetapi film horor Indonesia kurang dapat menyebar di pasaran Internasional. Oleh karena itu%2C suatu analisis diperlukan untuk mengetahui apakah kekuatan-kekuatan yang dimiliki oleh film horor negara-negara lain yang banyak digemari masyarakat global terutama dari sudut pandang kamera yang merupakan salah satu faktor penting dalam menciptakan kesan horor pada suatu film. Film The Ring 1 dipilih sebagai pedoman perbandingan film horor Indonesia%2C karena film The Ring 1 adalah film horor yang sangat banyak diminati oleh masyarakat di seluruh dunia%2C bahkan telah diremake oleh Korea dan USA. Film Horor Indonesia yang dipilih adalah film Jelangkung yang pertama kali muncul pada film layar lebar dan menjadi cikal bakal munculnya banyak film layar lebar di Indonesia dengan genre yang sama. Analisa kedua film ini ditinjau dari sudut pandang kamera yang dapat menampilkan kesan horor. horror movie%2C camera angle%2C Indonesia%2C Japan.

  16. Longitudinal and bulk viscosities of Lennard-Jones fluids

    Science.gov (United States)

    Tankeshwar, K.; Pathak, K. N.; Ranganathan, S.

    1996-12-01

    Expressions for the longitudinal and bulk viscosities have been derived using Green Kubo formulae involving the time integral of the longitudinal and bulk stress autocorrelation functions. The time evolution of stress autocorrelation functions are determined using the Mori formalism and a memory function which is obtained from the Mori equation of motion. The memory function is of hyperbolic secant form and involves two parameters which are related to the microscopic sum rules of the respective autocorrelation function. We have derived expressions for the zeroth-, second-and fourth- order sum rules of the longitudinal and bulk stress autocorrelation functions. These involve static correlation functions up to four particles. The final expressions for these have been put in a form suitable for numerical calculations using low- order decoupling approximations. The numerical results have been obtained for the sum rules of longitudinal and bulk stress autocorrelation functions. These have been used to calculate the longitudinal and bulk viscosities and time evolution of the longitudinal stress autocorrelation function of the Lennard-Jones fluids over wide ranges of densities and temperatures. We have compared our results with the available computer simulation data and found reasonable agreement.

  17. Longitudinal beam compression for heavy-ion inertial fusion

    International Nuclear Information System (INIS)

    Ho, D.D.M.; Brandon, S.T.

    1991-01-01

    A scheme is described for compressing a heavy-ion beam longitudinally in such a way that the compressed pulse has uniform line-charge density and longitudinal momentum. Attaining these conditions will be important in the final focusing of a beam on a small fuel capsule in an inertial confinement fusion reactor. The longitudinal dynamics can be approximately described by a one-dimensional (1-D) fluid model for charged particles. Recognizing the similarity between the 1-D charged particle equations of motion and the 1-D equations for ideal-gas flow permits us to calculate the evolution of the line-charge density and velocity profile using self-similar solutions and the method of characteristics, developed for unsteady supersonic gas dynamics, for different regions along the beam. Simple physical arguments show that although the longitudinal and transverse temperatures vary along the beam following the adiabatic laws, no substantial longitudinal and transverse emittance growth is to be expected. Particle-in-cell simulations confirm all the physical arguments. The compressed beam has negligible longitudinal momentum spread and can therefore avoid chromatic aberrations in final focus. (author) 24 refs., 5 figs., 1 tab

  18. Electrochromic nanocomposite films

    Science.gov (United States)

    Milliron, Delia; Llordes, Anna; Buonsanti, Raffaella; Garcia, Guillermo

    2018-04-10

    The present invention provides an electrochromic nanocomposite film. In an exemplary embodiment, the electrochromic nanocomposite film, includes (1) a solid matrix of oxide based material and (2) transparent conducting oxide (TCO) nanostructures embedded in the matrix. In a further embodiment, the electrochromic nanocomposite film farther includes a substrate upon which the matrix is deposited. The present invention also provides a method of preparing an electrochromic nanocomposite film.

  19. Defining Documentary Film

    DEFF Research Database (Denmark)

    Juel, Henrik

    2006-01-01

    A discussion of various attemts at defining documentary film regarding form, content, truth, stile, genre or reception - and a propoposal of a positive list of essential, but non-exclusive characteristica of documentary film......A discussion of various attemts at defining documentary film regarding form, content, truth, stile, genre or reception - and a propoposal of a positive list of essential, but non-exclusive characteristica of documentary film...

  20. Film Noir Style Genealogy

    OpenAIRE

    Rietuma, Dita

    2012-01-01

    Annotation for the Doctoral Work Film Noir Style Genealogy (The Genealogy of the Film Noir Style) The doctoral work topic Film Noir Style Genealogy encompasses traditionally approved world film theory views on the concept of film noir and its related cinematographic heritage, and an exploration of its evolution and distinctive style, including – the development of film noir in the USA, Europe, and also in Latvia, within the context of both socio-political progression and the paradigm of m...

  1. ZnO film deposition on Al film and effects of deposition temperature on ZnO film growth characteristics

    International Nuclear Information System (INIS)

    Yoon, Giwan; Yim, Munhyuk; Kim, Donghyun; Linh, Mai; Chai, Dongkyu

    2004-01-01

    The effects of the deposition temperature on the growth characteristics of the ZnO films were studied for film bulk acoustic wave resonator (FBAR) device applications. All films were deposited using a radio frequency magnetron sputtering technique. It was found that the growth characteristics of ZnO films have a strong dependence on the deposition temperature from 25 to 350 deg. C. ZnO films deposited below 200 deg. C exhibited reasonably good columnar grain structures with highly preferred c-axis orientation while those above 200 deg. C showed very poor columnar grain structures with mixed-axis orientation. This study seems very useful for future FBAR device applications

  2. Preferred orientation in Cr- and Co-based thin films and its effects on the read/write performance of the media

    Science.gov (United States)

    Tsai, Hsiao-chu; Lal, Brij B.; Eltoukhy, Atef

    1992-04-01

    This work investigates the formation of preferred crystallographic orientation (PO) in Cr underlayer as well as CoCrTa and CoCrPtTa thin films and its effects on the recording performance of longitudinal media. The results show that the thin-film media with comparable coercivity but different crystalline PO as measured by x-ray diffraction exhibit significant difference in high-frequency signal amplitude, pulse width, and signal-to-noise ratio. To illustrate the effect of PO on parametric performance, CoCrTa/Cr and CoCrPtTa/Cr media were sputtered on different substrates and/or using special sputtering processes to achieve comparable coercivity but different PO in the films. A PO of Cr(200), which normally occurs on the NiP/Al substrates under adequate sputtering conditions, is found to be the key to obtaining a PO of Co(11.0) in Co-alloy media. The consequence of preferred in-plane c-axis orientation is a higher coercivity and better parametric performance of the medium. The formation of PO in the Cr underlayer is found to be related to the substrate material and the oxygen content in the sputtered films. The nonmetallic canasite substrates tend to promote PO of more stable Cr(110) rather than Cr(200). Consequently, this leads to a PO of out-of-plane c axis on the following Co films. The PO of magnetic layer appears to be an important factor in determining the parametric performance of the media.

  3. Optoelectronic study and annealing stability of room temperature pulsed laser ablated ZnSe polycrystalline thin films

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Taj Muhammad, E-mail: tajakashne@gmail.com; Zakria, M.; Ahmad, Mushtaq; Shakoor, Rana I.

    2014-03-15

    In principal, we described stability of the room temperature ZnSe thin films with thermal annealing deposited onto glass by pulsed laser deposition technique using third harmonic 355 nm of Nd: YAG laser beam. Optoelectronic analysis and stability with thermal annealing was described in terms of structural and optical properties. These properties were investigated via X-ray diffraction, atomic force microscope, scanning electron microscope, Raman, Fourier transform infrared and photoluminescence spectroscopies. From the strong reflection corresponding to the (1 1 1) plane (2θ=27.48°) and the longitudinal optical “LO” phonon modes at 250 cm{sup −1} and 500 cm{sup −1} in the X-ray diffraction and Raman spectra, a polycrystalline zincblende structure of the film was established. At 300 and 350 °C annealing temperatures, the film crystallites were preferentially oriented with the (1 1 1) plane parallel to the substrate and became amorphous at 400 °C. Atomic force microscopic images showed that the morphologies of ZnSe films became smooth with root mean squared roughness 9.86 nm after annealing at 300 and 350 °C while a rougher surface was observed for the amorphous film at 400 °C. Fourier transform infrared study illustrated the chemical nature and Zn–Se bonding in the deposited films. For the as-deposited and annealed samples at 300 and 350 °C, scanning electron micrographs revealed mono-dispersed indistinguishable ZnSe grains and smooth morphological structure which changed to a cracking and bumpy surface after annealing at 400 °C. The physical phenomenon of annealing induced morphological changes could be explained in terms of “structure zone model”. Excitonic emission at 456 nm was observed for both as-deposited and annealed film at 350 °C. The transmission spectrum shows oscillatory behavior because of the thin film interference and exhibited a high degree of transparency down to a wavelength ∼500 nm in the IR region. Energy band-gap was

  4. Science Fiction on Film.

    Science.gov (United States)

    Burmester, David

    1985-01-01

    Reviews science fiction films used in a science fiction class. Discusses feature films, short science fiction films, short story adaptations, original science fiction pieces and factual science films that enrich literature. (EL)

  5. Thin Film Microbatteries

    International Nuclear Information System (INIS)

    Dudney, Nancy J.

    2008-01-01

    Thin film batteries are built layer by layer by vapor deposition. The resulting battery is formed of parallel plates, much as an ordinary battery construction, just much thinner. The figure (Fig. 1) shows an example of a thin film battery layout where films are deposited symmetrically onto both sides of a supporting substrate. The full stack of films is only 10 to 15 (micro)m thick, but including the support at least doubles the overall battery thickness. When the support is thin, the entire battery can be flexible. At least six companies have commercialized or are very close to commercializing such all-solid-state thin film batteries and market research predicts a growing market and a variety of applications including sensors, RFID tags, and smarter cards. In principle with a large deposition system, a thin film battery might cover a square meter, but in practice, most development is targeting individual cells with active areas less than 25 cm 2 . For very small battery areas, 2 , microfabrication processes have been developed. Typically the assembled batteries have capacities from 0.1 to 5 mAh. The operation of a thin film battery is depicted in the schematic diagram (Fig. 2). Very simply, when the battery is allowed to discharge, a Li + ion migrates from the anode to the cathode film by diffusing through the solid electrolyte. When the anode and cathode reactions are reversible, as for an intercalation compound or alloy, the battery can be recharged by reversing the current. The difference in the electrochemical potential of the lithium determines the cell voltage. Most of the thin films used in current commercial variations of this thin film battery are deposited in vacuum chambers by RF and DC magnetron sputtering and by thermal evaporation onto unheated substrates. In addition, many publications report exploring a variety of other physical and chemical vapor deposition processes, such as pulsed laser deposition, electron cyclotron resonance sputtering, and

  6. One-step aerosol synthesis of nanoparticle agglomerate films: simulation of film porosity and thickness

    International Nuclear Information System (INIS)

    Maedler, Lutz; Lall, Anshuman A; Friedlander, Sheldon K

    2006-01-01

    A method is described for designing nanoparticle agglomerate films with desired film porosity and film thickness. Nanoparticle agglomerates generated in aerosol reactors can be directly deposited on substrates to form uniform porous films in one step, a significant advance over existing technologies. The effect of agglomerate morphology and deposition mechanism on film porosity and thickness are discussed. Film porosity was calculated for a given number and size of primary particles that compose the agglomerates, and fractal dimension. Agglomerate transport was described by the Langevin equation of motion. Deposition enhancing forces such as thermophoresis are incorporated in the model. The method was validated for single spherical particles using previous theoretical studies. An S-shape film porosity dependence on the particle Peclet number typical for spherical particles was also observed for agglomerates, but films formed from agglomerates had much higher porosities than films from spherical particles. Predicted film porosities compared well with measurements reported in the literature. Film porosities increased with the number of primary particles that compose an agglomerate and higher fractal dimension agglomerates resulted in denser films. Film thickness as a function of agglomerate deposition time was calculated from the agglomerate deposition flux in the presence of thermophoresis. The calculated film thickness was in good agreement with measured literature values. Thermophoresis can be used to reduce deposition time without affecting the film porosity

  7. Development of In-plane Thermal Conductivity Calculation Methods in Thin Films

    Directory of Open Access Journals (Sweden)

    A. A. Barinov

    2017-01-01

    Full Text Available The future nanoelectronics development involves using the smaller- -and-smaller-sized circuit components based on the micro- and nanostructures. This causes a growth of the specific heat flows up to 100 W/cm2. Since performance of electronic devices is strongly dependent on the temperature there is a challenge to create the heat transfer models, which take into account the size effect and ensure a reliable estimate of the thermal conductivity. This is one of the crucial tasks for development of new generations of integrated circuits.The paper studies heat transfer processes using the silicon thin films as an example. Thermal conductivity calculations are performed taking into account the influence of the classical size effect in the context of the Sondheimer model based on the solution of the Boltzmann transport equation.The paper, for the first time, presents and considers the influence of various factors on the thermal conductivity of thin films, namely temperature, film thickness, polarization of the phonon waves (transverse and longitudinal, velocity and relaxation time versus frequency for the phonons of different wave types.Based on the analysis, three models with different accuracy are created to estimate the influence of detailing processes under consideration on the thermal conductivity in a wide range of temperatures (from 10 K to 450 К and film thickness (from 10 nm to 100 µm.So in the model I for the first time in calculating thermal conductivity of thin films we properly and circumstantially take into account the dependence of the velocity and the relaxation time of phonons on the frequency and polarization. The obtained values are in a good agreement with available experimental data and theoretical models of other authors. In the following models we use few average methods for relaxation times and velocities, which leads to significant reduction in calculating accuracy up to the values exceeding 100%.Therefore, when calculating

  8. Longitudinal research and data collection in primary care.

    Science.gov (United States)

    van Weel, Chris

    2005-01-01

    This article reviews examples of and experience with longitudinal research in family medicine. The objective is to use this empirical information to formulate recommendations for improving longitudinal research. The article discusses 3 longitudinal studies from the Nijmegen academic family practice research network: 1 on the prognosis of depression and 1 each on the prognosis of and outcomes of care for type 2 diabetes mellitus. The Nijmegen network has recorded all episodes of morbidity encountered in Dutch family medicine since 1971 in a stable practice population. This network's experience is evaluated to identify lessons that may help other practice-based research networks (PBRNs) in pursuing longitudinal research. In terms of external conditions (conditions related to the general setting), the stability of a population and a high level of continuity of care substantially enhance the ability to perform longitudinal research. In terms of internal conditions (conditions related to the PBRN), motivation of family physicians and their staff to conduct ongoing data collection, and their ownership of the data are key for success. Other critical internal conditions include standardization of data; collection of data by clinician-friendly means; training of family physicians and their staff in data collection, as well as meetings for discussion of this task; provision of feedback to practices on the research findings; use of standard procedures to promote adherence to data collection; availability of facilities for regular measurement of patients' health status or chart review; and use of mechanisms for tracking patients who leave the practice area. Insight from existing experience suggests that longitudinal research can be enhanced in PBRNs. The best way forward is to build longitudinal data collection by drawing on lessons from successful studies. Primary care research policy should advocate for a role of longitudinal research and stimulate its development in PBRNs

  9. Longitudinal drop-out and weighting against its bias

    Directory of Open Access Journals (Sweden)

    Steffen C. E. Schmidt

    2017-12-01

    Full Text Available Abstract Background The bias caused by drop-out is an important factor in large population-based epidemiological studies. Many studies account for it by weighting their longitudinal data, but to date there is no detailed final approach for how to conduct these weights. Methods In this study we describe the observed longitudinal bias and a three-step longitudinal weighting approach used for the longitudinal data in the MoMo baseline (N = 4528, 4–17 years and wave 1 study with 2807 (62% participants between 2003 and 2012. Results The most meaningful drop-out predictors were socioeconomic status of the household, socioeconomic characteristics of the mother and daily TV usage. Weighting reduced the bias between the longitudinal participants and the baseline sample, and also increased variance by 5% to 35% with a final weighting efficiency of 41.67%. Conclusions We conclude that a weighting procedure is important to reduce longitudinal bias in health-oriented epidemiological studies and suggest identifying the most influencing variables in the first step, then use logistic regression modeling to calculate the inverse of the probability of participation in the second step, and finally trim and standardize the weights in the third step.

  10. Longitudinal feedback system for PEP

    International Nuclear Information System (INIS)

    Allen, M.A.; Cornacchia, M.; Millich, A.

    1979-02-01

    Whether the wide bandwidth longitudinal feedback system described in this paper is made to act on the individual modes in frequency domain or on the individual bunches in time domain, it represents a clean and efficient way of damping the longitudinal oscillations without influencing other beam parameters such as bunch shape or synchrotron frequency distribution. The frequency domain feedback presents the advantage of providing information on which modes are unstable and on their risetimes, which may be helpful in locating dangerous resonators in the ring

  11. Longitudinal fluctuations and decorrelation of anisotropic flow

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Long-Gang [Frankfurt Institute for Advanced Studies, Ruth-Moufang-Strasse 1, 60438 Frankfurt am Main (Germany); Petersen, Hannah [Frankfurt Institute for Advanced Studies, Ruth-Moufang-Strasse 1, 60438 Frankfurt am Main (Germany); Institute for Theoretical Physics, Goethe University, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); Qin, Guang-You [Key Laboratory of Quark & Lepton Physics (MOE) and Institute of Particle Physics, Central China Normal University, Wuhan 430079 (China); Roy, Victor [Institute for Theoretical Physics, Goethe University, Max-von-Laue-Strasse 1, 60438 Frankfurt am Main (Germany); Wang, Xin-Nian [Key Laboratory of Quark & Lepton Physics (MOE) and Institute of Particle Physics, Central China Normal University, Wuhan 430079 (China); Nuclear Science Division MS70R0319, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2016-12-15

    We investigate the decorrelation of 2nd and 3rd order anisotropic flow for charged particles in two different pseudo rapidity (η) windows by varying the pseudo rapidity gap, in an event-by-event (3+1)D ideal hydrodynamic model, with fluctuating initial conditions from A Multi-Phase Transport (AMPT) model. We visualize the parton distribution at initial state for Pb+Pb collisions at LHC and Au+Au collisions at RHIC, and demonstrate the longitudinal fluctuations originating from the asymmetry between forward and backward going participants, the fluctuations of the string length and the fluctuations due to finite number of partons at different beam energies. The decorrelation of anisotropic flow of final hadrons with large η gaps is found to originate from the spatial decorrelation along the longitudinal direction in the AMPT initial conditions through hydrodynamic evolution. The agreement between our results and recent CMS data in most centralities suggests that the string-like mechanism of initial parton production in AMPT model captures the initial longitudinal fluctuation that is responsible for the measured decorrelation of anisotropic flow in Pb+Pb collisions at LHC. Our predictions for Au+Au collisions at the highest RHIC energy show stronger longitudinal decorrelation than at LHC, indicating larger longitudinal fluctuations at lower beam energies.

  12. Films--Too Good for Words. A Directory of Nonnarrated 16mm Films.

    Science.gov (United States)

    Parlato, Salvatore J., Jr.

    A nonnarrated film is one that communicates pictorially on the strength of its visual unity, continuity, and coherence without relying on narration or dialogue. This directory lists 1,000 such 16mm films, mostly curriculum-oriented educational films, in three main parts. The first part describes films under subject headings such as the arts, other…

  13. Gamification beyond badges

    CSIR Research Space (South Africa)

    Botha, Adèle

    2014-05-01

    Full Text Available Gamification in education refers to the application of game dynamics, mechanics into the teaching and learning engagement. This paper makes a case for viewing the objective of Educational Gamification as a Gameful Educational User Experience...

  14. Posterior longitudinal ligament status in cervical spine bilateral facet dislocations

    International Nuclear Information System (INIS)

    Carrino, John A.; Manton, Geoffrey L.; Morrison, William B.; Flanders, Adam E.; Vaccaro, Alex R.; Schweitzer, Mark E.

    2006-01-01

    It is generally accepted that cervical spine bilateral facet dislocation results in complete disruption of the posterior longitudinal ligament. The goal of this study was to evaluate the integrity of numerous spine-stabilizing structures by MRI, and to determine if any associations between injury patterns exist with respect to the posterior longitudinal ligament status. Retrospective case series. A retrospective review was performed of 30 cervical spine injury subjects with bilateral facet dislocation. Assessment of 1.5T MRI images was carried out for: intervertebral disc disruption, facet fracture, and ligamentous disruption. Statistical analyses were performed to evaluate for associations between various injury patterns and posterior longitudinal ligament status. The frequency of MRI abnormalities was: anterior longitudinal ligament disruption (26.7%), disc herniation or disruption (90%), posterior longitudinal ligament disruption (40%), facet fracture (63.3%) and disruption of the posterior column ligament complex (97%). There were no significant associations between injury to the posterior longitudinal ligament and other structures. Compared to surgical reports, MRI was accurate for determining the status for 24 of 26 ligaments (three of three anterior longitudinal ligament, seven of nine posterior longitudinal ligament, and 14 of 14 posterior column ligament complex) but generated false negatives in two instances (in both MRI showed an intact posterior longitudinal ligament that was torn at surgery). (orig.)

  15. Existence of longitudinal waves in pre-stressed anisotropic elastic ...

    Indian Academy of Sciences (India)

    waves is truly longitudinal. Longitudinal wave in an anisotropic elastic medium is defined as the wave motion in which the particle motion (i.e., the. Keywords. General anisotropy; elastic stiffness; pre-stress; group velocity; ray direction; longitudinal waves; polarization. J. Earth Syst. Sci. 118, No. 6, December 2009, pp. 677– ...

  16. Buy, Borrow, or Steal? Film Access for Film Studies Students

    Science.gov (United States)

    Rodgers, Wendy

    2018-01-01

    Libraries offer a mix of options to serve the film studies curriculum: streaming video, DVDs on Reserve, and streaming DVDs through online classrooms. Some professors screen films and lend DVDs to students. But how do students obtain the films required for their courses? How would they prefer to do so? These are among the questions explored using…

  17. Framing Persoalan Indonesia Melalui Film Dokumenter Model Direct Cinema (Studi Pada Film-film Dokumenter Terbaik, Program Eagle Award Competitions Di Metro TV)

    OpenAIRE

    Styo Wibowo, Novin Farid

    2013-01-01

    FRAMING PERSOALAN INDONESIA MELALUI FILM DOKUMENTER MODELDIRECT CINEMA(STUDI PADA FILM-FILM DOKUMENTER TERBAIK, PROGRAM EAGLEAWARD COMPETITIONS DI METRO TV)Frames Indonesia Issues Through Direct Cinema DocumentaryFilm On Television (Framing Analysis of the 3 Best Documentary Film, Eagle AwardCompetitions Program at Metro TV)Novin Farid Styo WibowoJurusan Ilmu Komunikasi, Fakultas Ilmu Sosial dan Ilmu PolitikUniversitas Muhammadiyah MalangEmail : TThe research disc...

  18. Uniformly irradiated polymer film

    International Nuclear Information System (INIS)

    Fowler, S.L.

    1979-01-01

    Irradiated film having substantial uniformity in the radiation dosage profile is produced by irradiating the film within a trough having lateral deflection blocks disposed adjacent the film edges for deflecting electrons toward the surface of the trough bottom for further deflecting the electrons toward the film edge

  19. Parameter optimization method for longitudinal vibration absorber of ship shaft system

    Directory of Open Access Journals (Sweden)

    LIU Jinlin

    2017-05-01

    Full Text Available The longitudinal vibration of the ship shaft system is the one of the most important factors of hull stern vibration, and it can be effectively minimized by installing a longitudinal vibration absorber. In this way, the vibration and noise of ships can be brought under control. However, the parameters of longitudinal vibration absorbers have a great influence on the vibration characteristics of the shaft system. As such, a certain shafting testing platform was studied as the object on which a finite model was built, and the relationship between longitudinal stiffness and longitudinal vibration in the shaft system was analyzed in a straight alignment state. Furthermore, a longitudinal damping model of the shaft system was built in which the parameters of the vibration absorber were non-dimensionalized, the weight of the vibration absorber was set as a constant, and an optimizing algorithm was used to calculate the optimized stiffness and damping coefficient of the vibration absorber. Finally, the longitudinal vibration frequency response of the shafting testing platform before and after optimizing the parameters of the longitudinal vibration absorber were compared, and the results indicated that the longitudinal vibration of the shafting testing platform was decreased effectively, which suggests that it could provide a theoretical foundation for the parameter optimization of longitudinal vibration absorbers.

  20. Terapia de linguagem de irmãos com transtornos invasivos do desenvolvimento: estudo longitudinal Language therapy of brothers with pervasive developmental disorders: longitudinal study

    Directory of Open Access Journals (Sweden)

    Andréa Regina Nunes Misquiatti

    2010-01-01

    years old - participated in the study. Subjects had diagnosis of autism (Case 1 and pervasive developmental disorder-not otherwise specified (Case 2, respectively. As a procedure for data collection and analysis, a longitudinal study was carried out through a follow up of the cases during the four years of language therapy. The procedure included filmed therapy sessions, documental analysis of information contained in the patients' records regarding anamnesis, assessments and therapeutic reports, and multidisciplinary evaluations and exams. In both cases there was an improvement on visual contact, social interaction, vocabulary and symbolic play. For Case 1, there was an increase from 2.0 to 6.2 communicative acts per minute; for Case 2, an increase from 3.5 to 8.0 acts. Both subjects demonstrated predominance of the verbal communicative mean and greater variety of communicative functions. Other factors influenced these results, such as the intellectual deficiency, the family dynamics, the conflicts on the relationship between the brothers and the school environment in which they were placed. The study confirmed the relevance of the speech-language pathologist in interventions of pervasive developmental disorders, along with multidisciplinary teams, for the discussion of diagnoses and of the most appropriate procedures. Longitudinal studies can contribute for more detailed and reliable analysis of therapeutic intervention in these cases, in order to clarify gaps existent in literature and to support the role of clinical speech-language pathologists.

  1. A Dosimetry Study of Deuterium-Deuterium Neutron Generator-based In Vivo Neutron Activation Analysis.

    Science.gov (United States)

    Sowers, Daniel; Liu, Yingzi; Mostafaei, Farshad; Blake, Scott; Nie, Linda H

    2015-12-01

    A neutron irradiation cavity for in vivo neutron activation analysis (IVNAA) to detect manganese, aluminum, and other potentially toxic elements in human hand bone has been designed and its dosimetric specifications measured. The neutron source is a customized deuterium-deuterium neutron generator that produces neutrons at 2.45 MeV by the fusion reaction 2H(d, n)3He at a calculated flux of 7 × 10(8) ± 30% s(-1). A moderator/reflector/shielding [5 cm high density polyethylene (HDPE), 5.3 cm graphite and 5.7 cm borated (HDPE)] assembly has been designed and built to maximize the thermal neutron flux inside the hand irradiation cavity and to reduce the extremity dose and effective dose to the human subject. Lead sheets are used to attenuate bremsstrahlung x rays and activation gammas. A Monte Carlo simulation (MCNP6) was used to model the system and calculate extremity dose. The extremity dose was measured with neutron and photon sensitive film badges and Fuji electronic pocket dosimeters (EPD). The neutron ambient dose outside the shielding was measured by Fuji NSN3, and the photon dose was measured by a Bicron MicroREM scintillator. Neutron extremity dose was calculated to be 32.3 mSv using MCNP6 simulations given a 10-min IVNAA measurement of manganese. Measurements by EPD and film badge indicate hand dose to be 31.7 ± 0.8 mSv for neutrons and 4.2 ± 0.2 mSv for photons for 10 min; whole body effective dose was calculated conservatively to be 0.052 mSv. Experimental values closely match values obtained from MCNP6 simulations. These are acceptable doses to apply the technology for a manganese toxicity study in a human population.

  2. Application of conventional chromosomal aberration and fluorescence in-situ hybridisation translocation in the assessment of occupationally derived irradiation

    International Nuclear Information System (INIS)

    Samavat, H.; Seaward, M. R. D.; Gonzales, D. H.; Azizian, Gh.

    2004-01-01

    Background: Most of our current understanding of the biological effects of exposure to ionising radiation is based on conventional cytogenetic techniques, which enable our to determine the relationship between chromosomal aberration and dose received by radiation workers. However, conventional techniques have numerous limitations and chromosomal aberrations can be easily missed. Since fluorescence in situ hybridisation plays an important role in detecting chromosomal changes, this method was used to reassess data derived from previous studies employing conventional techniques. Materials and Methods: Two groups of radiographers were the subject of a study on conventional chromosomal aberration and fluorescence in situ hybridisation for translocation. The first group was chosen following an accidental contamination incident in a nuclear medicine department. The second group was composed of six radiographers working in an x-ray department with a previous record of overdose as recorded by film-badges; these workers had been the subjects of a previous chromosomal study. Coded blood samples from 11 radiographers and 11 controls were analysed for chromosomal aberration and by fluorescence in-situ hybridisation for translocation. 200 metaphases from the peripheral blood lymphocytes per subject were analysed to investigate possible frequencies of chromosome and chromatid type aberration and 2000 metaphases per subject were scored in fluorescence in-situ hybridisation method. Results: There was no significant difference between the radiographers and the control groups in conventional analysis; also there was no significant difference at the 95 % level of confidence in fluorescence in-situ hybridisation analysis. There was no correlation between levels of translocation and total lifetime doses from occupational ( according film-badge and TLD) and/or background irradiation. Conclusion: The overall conclusion is that the frequency of chromosomal damage in both groups of

  3. Study of an accidental exposition of three workers during a gammagraphy with 192Ir source

    International Nuclear Information System (INIS)

    Bellintani, S.A.; Sahyun, A.; Graciotti, M.E.; Santos, O.R.; Alvares, R.

    1992-01-01

    'Full Text:' This paper is concerned with an accident occurred in an industrial gammagraphy unit located in Sao Paulo, Brazil, on 2nd of July, 1988. A work team, composed of three workers, was engaged on a routine operation with a 192 Ir source of 3,299 TBq, when the flexible cable of the holder broke, giving rise to an accidental exposure. The evaluation of the dose received by the three workers was carried out by three different methods: the film badge measurement, the biological dosimetry and the reconstitution of the accident taking into account the exposition time and the distance between the source and the workers. In the film badge evaluation the dose obtained was around 300 mSv, whereas for the biological dosimetry doses of 370 mSv, 290 mSv and 110 mSv was achieved. In the accident reconstitution the doses obtained where: 200 mSv (whole body), 131,000 mSv (left hand) for the first worker; 232 mSv (whole body), 25,000 mSv (left hand), 99,000 mSv (right hand), for the second one and finally 232 mSv (whole body) for the last one. It was concluded, by the evaluation for the doses, that the irradiation was not uniform, being the hand the more severely irradiated organ. From 18th of July, 1988, the victims were treated by the medical staff, together with the radiological protection group, both from the IPEN. In this paper the clinical and laboratorial exams carried out for the evaluation of the extension of the deleterious effects are described. By that time, the victims presented already radiodermatitis in their hands, and the clinical treatment pursued is also described. (author)

  4. Film in concert

    OpenAIRE

    2017-01-01

    From the very beginning of cinema, music always played an important role in the history of filmmaking. Nonetheless, film music is judged by critics as a kind of low-grade art form. However, the majority of film score composers enjoyed a classical education and composed as well for the silver screen as for the concert hall. Film music also has its roots in the musical era of romanticism. Therefore, symphonic film scores can be regarded as program music in a broader sense. These scores were inf...

  5. Modelling, simulation and applications of longitudinal train dynamics

    Science.gov (United States)

    Cole, Colin; Spiryagin, Maksym; Wu, Qing; Sun, Yan Quan

    2017-10-01

    Significant developments in longitudinal train simulation and an overview of the approaches to train models and modelling vehicle force inputs are firstly presented. The most important modelling task, that of the wagon connection, consisting of energy absorption devices such as draft gears and buffers, draw gear stiffness, coupler slack and structural stiffness is then presented. Detailed attention is given to the modelling approaches for friction wedge damped and polymer draft gears. A significant issue in longitudinal train dynamics is the modelling and calculation of the input forces - the co-dimensional problem. The need to push traction performances higher has led to research and improvement in the accuracy of traction modelling which is discussed. A co-simulation method that combines longitudinal train simulation, locomotive traction control and locomotive vehicle dynamics is presented. The modelling of other forces, braking propulsion resistance, curve drag and grade forces are also discussed. As extensions to conventional longitudinal train dynamics, lateral forces and coupler impacts are examined in regards to interaction with wagon lateral and vertical dynamics. Various applications of longitudinal train dynamics are then presented. As an alternative to the tradition single wagon mass approach to longitudinal train dynamics, an example incorporating fully detailed wagon dynamics is presented for a crash analysis problem. Further applications of starting traction, air braking, distributed power, energy analysis and tippler operation are also presented.

  6. Quality of YBCO thin films grown on LAO substrates exposed to the film deposition - film removal processes

    Energy Technology Data Exchange (ETDEWEB)

    Blagoev, B; Nurgaliev, T [Institute of Electronics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee, 1784 Sofia (Bulgaria); Mozhaev, P B [Institute of Physics and Technology, Russian Academy of Sciences, 117218 Moscow (Russian Federation); Sardela, M; Donchev, T [Materials Research Laboratory, University of Illinois, 104 South Goodwin Ave., Urbana, IL 61801 (United States)], E-mail: blago_sb@yahoo.com

    2008-05-01

    The characteristics are investigated of high temperature superconducting YBa{sub 2}Cu{sub 3}O{sub 7} (YBCO) films grown on LaAlO{sub 3} (LAO) substrates being exposed a different number of times to YBCO film deposition and acid-solution-based cleaning procedures. Possible mechanisms of degradation of the substrate surface quality reflecting on the growing YBCO film parameters are discussed and analyzed.

  7. Physicians, radiologists, and quality control

    International Nuclear Information System (INIS)

    Payne, W.F.

    1973-01-01

    Factors involved in quality control in medical x-ray examinations to achieve the least possible exposure to the patient are discussed. It would be hoped that film quality will remain in the position of paramount importance that it must in order to achieve the greatest amount of diagnostic information on each radiographic examination. At the same time, it is hoped that this can be done by further reducing the exposure of the patient to ionizing radiation by the methods that have been discussed; namely, education of the physician, radiologist, and technologist, modern protective equipment and departmental construction, efficient collimation whether automatic or manual, calibration and output measurement of the radiographic and fluoroscopic units, ongoing programs of education within each department of radiographic facility, film badge monitoring, education of and cooperation with the nonradiologic physician, and hopefully, more intensive programs by the National and State Bureaus and Departments of Radiological Health in education and encouragement to the medical community. (U.S.)

  8. Evaluation and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanning.

    Science.gov (United States)

    Palmer, Antony L; Bradley, David A; Nisbet, Andrew

    2015-03-08

    This work considers a previously overlooked uncertainty present in film dosimetry which results from moderate curvature of films during the scanning process. Small film samples are particularly susceptible to film curling which may be undetected or deemed insignificant. In this study, we consider test cases with controlled induced curvature of film and with film raised horizontally above the scanner plate. We also evaluate the difference in scans of a film irradiated with a typical brachytherapy dose distribution with the film naturally curved and with the film held flat on the scanner. Typical naturally occurring curvature of film at scanning, giving rise to a maximum height 1 to 2 mm above the scan plane, may introduce dose errors of 1% to 4%, and considerably reduce gamma evaluation passing rates when comparing film-measured doses with treatment planning system-calculated dose distributions, a common application of film dosimetry in radiotherapy. The use of a triple-channel dosimetry algorithm appeared to mitigate the error due to film curvature compared to conventional single-channel film dosimetry. The change in pixel value and calibrated reported dose with film curling or height above the scanner plate may be due to variations in illumination characteristics, optical disturbances, or a Callier-type effect. There is a clear requirement for physically flat films at scanning to avoid the introduction of a substantial error source in film dosimetry. Particularly for small film samples, a compression glass plate above the film is recommended to ensure flat-film scanning. This effect has been overlooked to date in the literature.

  9. Spectator's trust as an indicator of film authorship: Is Vinterberg a film auteur?

    NARCIS (Netherlands)

    van der Pol, G.

    2015-01-01

    In this article, the Trust Model is presented as a new theory to tackle the old film theoretical problem of distinguishing film directors from film auteurs. The model proposes that in certain films, the spectator becomes problematically engaged to the fiction and to certain characters. During the

  10. Upper-extremity phocomelia reexamined: a longitudinal dysplasia.

    Science.gov (United States)

    Goldfarb, Charles A; Manske, Paul R; Busa, Riccardo; Mills, Janith; Carter, Peter; Ezaki, Marybeth

    2005-12-01

    In contrast to longitudinal deficiencies, phocomelia is considered a transverse, intercalated segmental dysplasia. Most patients demonstrate severe, but not otherwise classifiable, upper-extremity deformities, which usually cannot be placed into one of three previously described phocomelia groups. Additionally, these phocomelic extremities do not demonstrate true segmental deficits; the limb is also abnormal proximal and distal to the segmental defect. The purpose of this investigation was to present evidence that upper-extremity abnormalities in patients previously diagnosed as having phocomelia in fact represent a proximal continuum of radial or ulnar longitudinal dysplasia. The charts and radiographs of forty-one patients (sixty extremities) diagnosed as having upper-extremity phocomelia were reviewed retrospectively. On the basis of the findings on the radiographs, the disorders were categorized into three groups: (1) proximal radial longitudinal dysplasia, which was characterized by an absent proximal part of the humerus, a nearly normal distal part of the humerus, a completely absent radius, and a radial-sided hand dysplasia; (2) proximal ulnar longitudinal dysplasia, characterized by a short one-bone upper extremity that bifurcated distally and by severe hand abnormalities compatible with ulnar dysplasia; and (3) severe combined dysplasia, with type A characterized by an absence of the forearm segment (i.e., the radius and ulna) and type B characterized by absence of the arm and forearm (i.e., the hand attached to the thorax). Twenty-nine limbs in sixteen patients could be classified as having proximal radial longitudinal dysplasia. Systemic medical conditions such as thrombocytopenia-absent radius syndrome were common in those patients, but additional musculoskeletal conditions were rare. Twenty limbs in seventeen patients could be classified as having proximal ulnar longitudinal dysplasia. Associated musculoskeletal abnormalities, such as proximal femoral

  11. Getting into Film.

    Science.gov (United States)

    London, Mel

    This book describes the various aspects of the film industry and the many jobs related to filmmaking, stressing that no "formula" exists for finding a successful career in the film industry. Chapters provide information on production, writing for film, cinematography, editing, music, sound, animation and graphics, acting and modeling, the "unsung…

  12. The Sponsored Film.

    Science.gov (United States)

    Klein, Walter J.

    For public relations professionals and would-be sponsors of films, this book provides guidelines for understanding the film medium and its potential as a persuasive force in industry, government, organizations, and religious orders. For filmmakers, it brings together practical information needed to survive in the sponsored-film industry and to…

  13. Sequential Progressions in a Theory of Mind Scale: Longitudinal Perspectives

    Science.gov (United States)

    Wellman, Henry M.; Fuxi, Fang; Peterson, Candida C.

    2011-01-01

    Consecutive re-testings of 92 U.S. preschoolers (n = 30), Chinese preschoolers (n = 31), and deaf children (n = 31) examined whether the sequences of development apparent in cross-sectional results with a theory-of-mind scale also appeared in longitudinal assessment. Longitudinal data confirmed that theory-of-mind progressions apparent in cross-sectional scaling data also characterized longitudinal sequences of understanding for individual children. The match between cross-sectional and longitudinal sequences appeared for children who exhibit different progressions across cultures (U.S. vs. China) and for children with substantial delays (deaf children of hearing parents). Moreover, greater scale distances reflected larger longitudinal age differences. PMID:21428982

  14. Requirements for longitudinal HOM damping in superconducting recirculating linacs

    International Nuclear Information System (INIS)

    Bisognano, J.J.; Fripp, M.L.

    1989-01-01

    Transverse beam breakup provides the primary current limitation in the operation of superconducting recirculating linacs and requires the significant damping of transverse-deflecting higher order modes. The need to damp the coexisting longitudinal HOMs in these nominally isochronous machines, however, is not as clear. Isochronicity implies that energy variations induced by excitation of longitudinal modes do not translate directly into position and current modulations. Such modulations, if present, could enhance the initial excitation, effectively closing a potentially unstable feedback loop. Design optimization of cavity structures may suggest that no longitudinal damping be provided. On the other hand, easing of the isochronicity requirement may provide desired flexibility in lattice design. In this note, limits are placed on the requirements for longitudinal HOM damping and on the tolerances for isochronicity which are driven by possible longitudinal multipass phenomena. 2 refs., 1 fig

  15. Effect of loading pattern on longitudinal bowing in flexible roll forming

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyun; Woo, Young Yun; Hwang, Tae Woo; Han, Sang Wook; Moon, Young Hoon [School of Mechanical Engineering, Engineering Research Center for Net Shape and Die Manufacturing, Pusan National University,Busan (Korea, Republic of)

    2016-12-15

    The flexible roll forming process can be used to fabricate products with a variable cross-section profile in the longitudinal direction. Transversal nonuniformity of the longitudinal strain is one of the fundamental characteristics of blank deformation in flexible roll forming. Longitudinal bowing is a shape defect caused by transversal nonuniformity of the longitudinal strain. In this study, loading patterns in flexible roll forming are investigated in order to reduce the longitudinal bowing in a roll-formed blank. To analyze the effects of loading patterns on longitudinal bowing, two different forming schedules are implemented. In schedule 1, loading patterns with different bending angle increments are designed under fixed initial and final bending angles. In schedule 2, loading patterns with different initial bending angles under the fixed final bending angle are designed. Our results show that the bowing heights are significantly affected by the loading patterns. The bowing susceptibilities vary with blank shape such as trapezoid, convex, and concave shapes. In addition to the peak longitudinal strain at the respective roll stands, the cumulative longitudinal strain from the initial to final stands is shown to be a reliable index in predicting the tendency of longitudinal bowing.

  16. College Women's Female Friendships: A Longitudinal View

    Science.gov (United States)

    Aleman, Ana M. Martinez

    2010-01-01

    This article presents a longitudinal qualitative study of the cognitive value of female friendships formed in college and seeks to appraise the meaning of the phenomenon for the participants. To grasp the temporal effects of the longitudinal data in this study, the author examines and assesses the relevant developmental literature, particularly…

  17. 14 CFR 23.173 - Static longitudinal stability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Static longitudinal stability. 23.173... Stability § 23.173 Static longitudinal stability. Under the conditions specified in § 23.175 and with the airplane trimmed as indicated, the characteristics of the elevator control forces and the friction within...

  18. The dorsal tectal longitudinal column (TLCd): a second longitudinal column in the paramedian region of the midbrain tectum.

    Science.gov (United States)

    Aparicio, M-Auxiliadora; Saldaña, Enrique

    2014-03-01

    The tectal longitudinal column (TLC) is a longitudinally oriented, long and narrow nucleus that spans the paramedian region of the midbrain tectum of a large variety of mammals (Saldaña et al. in J Neurosci 27:13108-13116, 2007). Recent analysis of the organization of this region revealed another novel nucleus located immediately dorsal, and parallel, to the TLC. Because the name "tectal longitudinal column" also seems appropriate for this novel nucleus, we suggest the TLC described in 2007 be renamed the "ventral tectal longitudinal column (TLCv)", and the newly discovered nucleus termed the "dorsal tectal longitudinal column (TLCd)". This work represents the first characterization of the rat TLCd. A constellation of anatomical techniques was used to demonstrate that the TLCd differs from its surrounding structures (TLCv and superior colliculus) cytoarchitecturally, myeloarchitecturally, neurochemically and hodologically. The distinct expression of vesicular amino acid transporters suggests that TLCd neurons are GABAergic. The TLCd receives major projections from various areas of the cerebral cortex (secondary visual mediomedial area, and granular and dysgranular retrosplenial cortices) and from the medial pretectal nucleus. It densely innervates the ipsilateral lateral posterior and laterodorsal nuclei of the thalamus. Thus, the TLCd is connected with vision-related neural centers. The TLCd may be unique as it constitutes the only known nucleus made of GABAergic neurons dedicated to providing massive inhibition to higher order thalamic nuclei of a specific sensory modality.

  19. Ceramic Composite Thin Films

    Science.gov (United States)

    Ruoff, Rodney S. (Inventor); Stankovich, Sasha (Inventor); Dikin, Dmitriy A. (Inventor); Nguyen, SonBinh T. (Inventor)

    2013-01-01

    A ceramic composite thin film or layer includes individual graphene oxide and/or electrically conductive graphene sheets dispersed in a ceramic (e.g. silica) matrix. The thin film or layer can be electrically conductive film or layer depending the amount of graphene sheets present. The composite films or layers are transparent, chemically inert and compatible with both glass and hydrophilic SiOx/silicon substrates. The composite film or layer can be produced by making a suspension of graphene oxide sheet fragments, introducing a silica-precursor or silica to the suspension to form a sol, depositing the sol on a substrate as thin film or layer, at least partially reducing the graphene oxide sheets to conductive graphene sheets, and thermally consolidating the thin film or layer to form a silica matrix in which the graphene oxide and/or graphene sheets are dispersed.

  20. Solid thin film materials for use in thin film charge-coupled devices

    International Nuclear Information System (INIS)

    Lynch, S.J.

    1983-01-01

    Solid thin films deposited by vacuum deposition were evaluated to ascertain their effectiveness for use in the manufacturing of charge-coupled devices (CCDs). Optical and electrical characteristics of tellurium and Bi 2 Te 3 solid thin films were obtained in order to design and to simulate successfully the operation of thin film (TF) CCDs. In this article some of the material differences between single-crystal material and the island-structured thin film used in TFCCDs are discussed. The electrical parameters were obtained and tabulated, e.g. the mobility, conductivity, dielectric constants, permittivity, lifetime of holes and electrons in the thin films and drift diffusion constants. The optical parameters were also measured and analyzed. After the design was complete, experimental TFCCDs were manufactured and were successfully operated utilizing the aforementioned solid thin films. (Auth.)

  1. [Application of biodegradable plastic film to reduce plastic film residual pollution in Chinese agriculture].

    Science.gov (United States)

    Yan, Changrong; He, Wenqing; Xue, Yinghao; Liu, Enke; Liu, Qin

    2016-06-25

    Plastic film has become an important agriculture production material in recent years. Over the past three decades, the amount and application area of plastic film have increased steadily, and in 2014, which are 1.4 million tons and more than 180 million hm² respectively. It plays a key role for ensuring the supply of agricultural goods in China. Meanwhile, plastic film residual pollution becomes more and more serious, and in some regions, the amount of plastic film residues has reached over 250 kg/hm². In part of the Northwest region, soil structure of farmland has been destroyed by plastic film residues and then crop growth and farming operations were suppressed. It is recognized as a good choice to replace plastic film with biodegradable plastic film, an effective measure to solve the plastic film residue pollution. Now, it is in a critical stage of study and assessment of biodegradable plastic film in China and fortunately some biodegradable plastic films show effects in the production of potatoes, peanuts and tobacco. Overall, a series of challenges has still been faced by the biodegradable plastic film, mainly including improving the quality of biodegradable plastic products, such as tensile strength, flexibility, improving the controllability of rupture and degradation, enhancing the ability of increasing soil temperature and preserving soil moisture, and to satisfy the demand of crops production with mulching. In addition, it is essential to reduce the cost of the biodegradable film and promote the application of biodegradable film on large-scale. With the development of biodegradable plastic technology and agricultural production environment, the application of the biodegradable film will have a good future.

  2. IAEA film library

    International Nuclear Information System (INIS)

    1959-01-01

    Most of the scientific and technical films shown during the Second Geneva Conference for the Peaceful Uses of Atomic Energy were donated to IAEA by the producing countries at the end of the Conference. They will form the basic stock for the Agency's loan service intended to provide atomic energy institutions in Member States with film material. A detailed catalogue of the films, classified according to subject and giving conditions of loan or purchase, is now being prepared. In addition to this, information on all films produced in Member Countries dealing with the peaceful uses cf atomic energy is being assembled. The documentary information contained in the films in IAEA's possession relates to the following subjects: national programmes; nuclear physics; accelerators; plasma and fusion; reactors (power, research, material testing and experimental); prospecting and mining; ore dressing; metallurgy; production of fuel elements; treatment of irradiated fuel elements; protection against radiation; detection and counting; uses of radiation in medicine, biochemistry, agriculture and industry; industrial application of nuclear explosions. Most of the commentaries are in the language of the producing country. A few films are available in a choice of two languages. The films donated to the Agency total 82, two of which have been produced in Canada, 13 in France, one in India, one in Romania, one in Spain, 14 in the United Kingdom, one in the Union of South Africa, 47 in the United States of America and two in the USSR: they are mostly illustrations of papers presented at the Second Geneva Conference. In arranging for the circulation of scientific and technical films IAEA wishes to help meet some of the training and information needs of Member States. It is hoped that all organizations producing films on the peaceful uses of atomic energy will entrust copies to the IAEA with a view to their widest possible circulation. In the meantime, the Agency's films have been given

  3. IAEA film library

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1959-01-15

    Most of the scientific and technical films shown during the Second Geneva Conference for the Peaceful Uses of Atomic Energy were donated to IAEA by the producing countries at the end of the Conference. They will form the basic stock for the Agency's loan service intended to provide atomic energy institutions in Member States with film material. A detailed catalogue of the films, classified according to subject and giving conditions of loan or purchase, is now being prepared. In addition to this, information on all films produced in Member Countries dealing with the peaceful uses cf atomic energy is being assembled. The documentary information contained in the films in IAEA's possession relates to the following subjects: national programmes; nuclear physics; accelerators; plasma and fusion; reactors (power, research, material testing and experimental); prospecting and mining; ore dressing; metallurgy; production of fuel elements; treatment of irradiated fuel elements; protection against radiation; detection and counting; uses of radiation in medicine, biochemistry, agriculture and industry; industrial application of nuclear explosions. Most of the commentaries are in the language of the producing country. A few films are available in a choice of two languages. The films donated to the Agency total 82, two of which have been produced in Canada, 13 in France, one in India, one in Romania, one in Spain, 14 in the United Kingdom, one in the Union of South Africa, 47 in the United States of America and two in the USSR: they are mostly illustrations of papers presented at the Second Geneva Conference. In arranging for the circulation of scientific and technical films IAEA wishes to help meet some of the training and information needs of Member States. It is hoped that all organizations producing films on the peaceful uses of atomic energy will entrust copies to the IAEA with a view to their widest possible circulation. In the meantime, the Agency's films have been given

  4. 32 CFR 507.6 - Authority to manufacture.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Authority to manufacture. 507.6 Section 507.6... PUBLIC RELATIONS MANUFACTURE AND SALE OF DECORATIONS, MEDALS, BADGES, INSIGNIA, COMMERCIAL USE OF HERALDIC DESIGNS AND HERALDIC QUALITY CONTROL PROGRAM Manufacture and Sale of Decorations, Medals, Badges...

  5. Film: Genres and Genre Theory

    DEFF Research Database (Denmark)

    Bondebjerg, Ib

    2015-01-01

    Genre is a concept used in film studies and film theory to describe similarities between groups of films based on aesthetic or broader social, institutional, cultural, and psychological aspects. Film genre shares similarities in form and style, theme, and communicative function. A film genre...

  6. A study of dose equivalent for the nurses in Hirosaki University Hospital

    International Nuclear Information System (INIS)

    Kon, Masanori; Abe, Katsumi

    2001-01-01

    The annual relationships in 1997-1999 between exposure dose of those nurses engaging in full-time radiological works and the number of patients subjected to radiological examinations were investigated in authors' hospital. The annual number of those patients was rather constant. Exposure was measured by film-, carrot- and ring-badges. Eight to nine nurses engaged in radiological examinations like CT, fluoroscopy, urinary tract fluoroscopy and angiography, and other 8 nurses, therapy with sealed 137 Cs and 192 Ir and unsealed 131 I as well. No significant changes in exposure dose were observed in the former group of nurses and in the latter. The dose decreased annually to the level of the former due to skill advancement. (K.H.)

  7. Performing personnel dosimetry investigations and records quality assurance

    International Nuclear Information System (INIS)

    Perle, S.C.

    2002-01-01

    Radiation Safety Officers (RSOs) sometimes face situations in which personnel dosimetry estimates are required after dosimeters issued to radiation workers (film or TLD badges, extremity dosimeters, etc.) are lost or damaged before processing. This article was prepared to help those involved with personnel dosimetry investigations became aquatinted with this process. A factor that contributes to the anxiety of those unfamiliar with dosimetry investigations is the lack of published guidance available in this subject. More printed resources are needed to help radiation safety professionals familiarize themselves and understand personnel dosimetry investigations. Topics discussed in this presentation include the justification of performing dosimetry investigations, recommendations on how to perform them and the advantages of performing such investigations

  8. Radiation detectors for personnel monitoring - current developments and future trends

    International Nuclear Information System (INIS)

    Kannan, S.

    2003-01-01

    The radiation detectors for personnel monitoring range from the conventional passive dosimeters like the film badge and the TLD, to sophisticated active dosimeters for integrated gamma, beta and neutron dose measurement. With the availability of high accuracy active dosimeters, the process of personnel monitoring, acceptability among radiation workers, record keeping and dose control have become more simplified. However the high level of sophistication in the active dosimeter has its own inevitable price tag and the new breed of active dosimeters are prohibitively costly. The silver lining, in the otherwise dark cost scenario of these dosimeters is the potential for cost reduction at least in some of the dosimeters in the near future

  9. Meteor Film Recording with Digital Film Cameras with large CMOS Sensors

    Science.gov (United States)

    Slansky, P. C.

    2016-12-01

    In this article the author combines his professional know-how about cameras for film and television production with his amateur astronomy activities. Professional digital film cameras with high sensitivity are still quite rare in astronomy. One reason for this may be their costs of up to 20 000 and more (camera body only). In the interim, however,consumer photo cameras with film mode and very high sensitivity have come to the market for about 2 000 EUR. In addition, ultra-high sensitive professional film cameras, that are very interesting for meteor observation, have been introduced to the market. The particular benefits of digital film cameras with large CMOS sensors, including photo cameras with film recording function, for meteor recording are presented by three examples: a 2014 Camelopardalid, shot with a Canon EOS C 300, an exploding 2014 Aurigid, shot with a Sony alpha7S, and the 2016 Perseids, shot with a Canon ME20F-SH. All three cameras use large CMOS sensors; "large" meaning Super-35 mm, the classic 35 mm film format (24x13.5 mm, similar to APS-C size), or full format (36x24 mm), the classic 135 photo camera format. Comparisons are made to the widely used cameras with small CCD sensors, such as Mintron or Watec; "small" meaning 12" (6.4x4.8 mm) or less. Additionally, special photographic image processing of meteor film recordings is discussed.

  10. Radiation monitoring policy at the advanced light source

    International Nuclear Information System (INIS)

    Donahue, R.; Heinzelman, K.; Perdue, G.

    1998-01-01

    When the accelerator first began operation it was decided that, until we had the necessary dosimetry data to decide otherwise, we would badge the entire worker and experimental population. Each person was issued a dosimetry badge that contained 4 TLD elements. Badges were processed on a monthly basis. After three years of analyzing a total of 65,000 TLD elements, the decision was made to modify the radiation monitoring policy at the ALS. Only those individuals in the workforce that have any potential for exposure, no matter how small, would be badged. Subsequently, DOE conducted an independent review of the ALS radiation monitoring and dosimetry program. This review concluded that the ALS program, if expanded as proposed, would be adequate under the 10 CFR 835 Rule to establish radiation exposures to an acceptable level of confidence. The review team recommended the ALS provide more comprehensive documentation on the basis for its radiation protection and monitoring program. This document describes the technical justification for that program

  11. Variable selection and estimation for longitudinal survey data

    KAUST Repository

    Wang, Li; Wang, Suojin; Wang, Guannan

    2014-01-01

    There is wide interest in studying longitudinal surveys where sample subjects are observed successively over time. Longitudinal surveys have been used in many areas today, for example, in the health and social sciences, to explore relationships

  12. The Role of Microsimulation in Longitudinal Data Analysis

    Directory of Open Access Journals (Sweden)

    Douglas A. Wolf

    2001-12-01

    microsimulation also has the potential to contribute to longitudinal data analysis in several ways, including extending the range of outputs generated by a model, addressing several defective-data problems, and serving as a vehicle for missing-data imputation. This paper discusses microsimulation procedures suitable for several commonly-used statistical models applied to longitudinal data. It also addresses the unique role that can be played by microsimulation in longitudinal data analysis, and the problem of accounting for the several sources of variability associated with microsimulation procedures.

  13. Demens Film

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2012-01-01

    I forbindelse med opstarten af Demens Film projektet har der været nedsat en ekspertgruppe, som er kommet med en række anbefalinger omkring film til mennesker med demens. Anbefalingerne skal bruges i de næste faser af projektet. Deltagerne i ekspertgruppen var sammensat af en bred gruppe...... fagpersoner inde for forskellige fagområder. Læs mere om gruppens anbefalinger og sammensætning af ekspertgruppen i den kort rapport som er offentlig tilgængelig. Læs Ekspertgruppe anbefalingerne til Demens Film projekt....

  14. Effect of diffraction and film-thickness gradients on wafer-curvature measurements of thin-film stress

    International Nuclear Information System (INIS)

    Breiland, W.G.; Lee, S.R.; Koleske, D.D.

    2004-01-01

    When optical measurements of wafer curvature are used to determine thin-film stress, the laser beams that probe the sample are usually assumed to reflect specularly from the curved surface of the film and substrate. Yet, real films are not uniformly thick, and unintended thickness gradients produce optical diffraction effects that steer the laser away from the ideal specular condition. As a result, the deflection of the laser in wafer-curvature measurements is actually sensitive to both the film stress and the film-thickness gradient. We present a Fresnel-Kirchhoff optical diffraction model of wafer-curvature measurements that provides a unified description of these combined effects. The model accurately simulates real-time wafer-curvature measurements of nonuniform GaN films grown on sapphire substrates by vapor-phase epitaxy. During thin-film growth, thickness gradients cause the reflected beam to oscillate asymmetrically about the ideal position defined by the stress-induced wafer curvature. This oscillating deflection has the same periodicity as the reflectance of the growing film, and the deflection amplitude is a function of the film-thickness gradient, the mean film thickness, the wavelength distribution of the light source, the illuminated spot size, and the refractive indices of the film and substrate. For typical GaN films grown on sapphire, misinterpretation of these gradient-induced oscillations can cause stress-measurement errors that approach 10% of the stress-thickness product; much greater errors occur in highly nonuniform films. Only transparent films can exhibit substantial gradient-induced deflections; strongly absorbing films are immune

  15. Film-thickness and composition dependence of epitaxial thin-film PZT-based

    NARCIS (Netherlands)

    Nguyen, Duc Minh; Dekkers, Jan M.; Vu, Hung Ngoc; Rijnders, Augustinus J.H.M.

    2013-01-01

    The transverse piezoelectric coefficient e31,f and mass-sensitivity were measured on piezoelectric cantilevers based on epitaxial PZT thin-films with film-thicknesses ranging from 100 to 2000 nm. The highest values of e31,f and mass-sensitivity were observed at a film thickness of 500–750 nm, while

  16. Development of Anti-Insect Microencapsulated Polypropylene Films Using a Large Scale Film Coating System.

    Science.gov (United States)

    Song, Ah Young; Choi, Ha Young; Lee, Eun Song; Han, Jaejoon; Min, Sea C

    2018-04-01

    Films containing microencapsulated cinnamon oil (CO) were developed using a large-scale production system to protect against the Indian meal moth (Plodia interpunctella). CO at concentrations of 0%, 0.8%, or 1.7% (w/w ink mixture) was microencapsulated with polyvinyl alcohol. The microencapsulated CO emulsion was mixed with ink (47% or 59%, w/w) and thinner (20% or 25%, w/w) and coated on polypropylene (PP) films. The PP film was then laminated with a low-density polyethylene (LDPE) film on the coated side. The film with microencapsulated CO at 1.7% repelled P. interpunctella most effectively. Microencapsulation did not negatively affect insect repelling activity. The release rate of cinnamaldehyde, an active repellent, was lower when CO was microencapsulated than that in the absence of microencapsulation. Thermogravimetric analysis exhibited that microencapsulation prevented the volatilization of CO. The tensile strength, percentage elongation at break, elastic modulus, and water vapor permeability of the films indicated that microencapsulation did not affect the tensile and moisture barrier properties (P > 0.05). The results of this study suggest that effective films for the prevention of Indian meal moth invasion can be produced by the microencapsulation of CO using a large-scale film production system. Low-density polyethylene-laminated polypropylene films printed with ink incorporating microencapsulated cinnamon oil using a large-scale film production system effectively repelled Indian meal moth larvae. Without altering the tensile and moisture barrier properties of the film, microencapsulation resulted in the release of an active repellent for extended periods with a high thermal stability of cinnamon oil, enabling commercial film production at high temperatures. This anti-insect film system may have applications to other food-packaging films that use the same ink-printing platform. © 2018 Institute of Food Technologists®.

  17. Australian Film Studies.

    Science.gov (United States)

    Breen, Myles P.

    Although Australia had a vigorous film industry in the silent film era, it was stifled in the 1930s when United States and British interests bought up the Australian distribution channels and closed down the indigenous industry. However, the industry and film study have undergone a renaissance since the advent of the Labor government in 1972,…

  18. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  19. Longitudinal dynamics in storage rings

    International Nuclear Information System (INIS)

    Colton, E.P.

    1986-01-01

    The single-particle equations of motion are derived for charged particles in a storage ring. Longitudinal space charge is included in the potential assuming an infinitely conducting circular beam pipe with a distributed inductance. The framework uses Hamilton's equations with the canonical variables phi and W. The Twiss parameters for longitudinal motion are also defined for the small amplitude synchrotron oscillations. The space-charge Hamiltonian is calculated for both parabolic bunches and ''matched'' bunches. A brief analysis including second-harmonic rf contributions is also given. The final sections supply calculations of dynamical quantities and particle simulations with the space-charge effects neglected

  20. Passive longitudinal phase space linearizer

    Directory of Open Access Journals (Sweden)

    P. Craievich

    2010-03-01

    Full Text Available We report on the possibility to passively linearize the bunch compression process in electron linacs for the next generation x-ray free electron lasers. This can be done by using the monopole wakefields in a dielectric-lined waveguide. The optimum longitudinal voltage loss over the length of the bunch is calculated in order to compensate both the second-order rf time curvature and the second-order momentum compaction terms. Thus, the longitudinal phase space after the compression process is linearized up to a fourth-order term introduced by the convolution between the bunch and the monopole wake function.

  1. P-type CuxS thin films: Integration in a thin film transistor structure

    International Nuclear Information System (INIS)

    Nunes de Carvalho, C.; Parreira, P.; Lavareda, G.; Brogueira, P.; Amaral, A.

    2013-01-01

    Cu x S thin films, 80 nm thick, are deposited by vacuum thermal evaporation of sulfur-rich powder mixture, Cu 2 S:S (50:50 wt.%) with no intentional heating of the substrate. The process of deposition occurs at very low deposition rates (0.1–0.3 nm/s) to avoid the formation of Cu or S-rich films. The evolution of Cu x S films surface properties (morphology/roughness) under post deposition mild annealing in air at 270 °C and their integration in a thin film transistor (TFT) are the main objectives of this study. Accordingly, Scanning Electron Microscopy studies show Cu x S films with different surface morphologies, depending on the post deposition annealing conditions. For the shortest annealing time, the Cu x S films look to be constructed of grains with large dimension at the surface (approximately 100 nm) and consequently, irregular shape. For the longest annealing time, films with a fine-grained surface are found, with some randomly distributed large particles bound to this fine-grained surface. Atomic Force Microscopy results indicate an increase of the root-mean-square roughness of Cu x S surface with annealing time, from 13.6 up to 37.4 nm, for 255 and 345 s, respectively. The preliminary integration of Cu x S films in a TFT bottom-gate type structure allowed the study of the feasibility and compatibility of this material with the remaining stages of a TFT fabrication as well as the determination of the p-type characteristic of the Cu x S material. - Highlights: • Surface properties of annealed Cu x S films. • Variation of conductivity with annealing temperatures of Cu x S films. • Application of evaporated Cu x S films in a thin film transistor (TFT) structure. • Determination of Cu x S p-type characteristic from TFT behaviour

  2. Thin film processes II

    CERN Document Server

    Kern, Werner

    1991-01-01

    This sequel to the 1978 classic, Thin Film Processes, gives a clear, practical exposition of important thin film deposition and etching processes that have not yet been adequately reviewed. It discusses selected processes in tutorial overviews with implementation guide lines and an introduction to the literature. Though edited to stand alone, when taken together, Thin Film Processes II and its predecessor present a thorough grounding in modern thin film techniques.Key Features* Provides an all-new sequel to the 1978 classic, Thin Film Processes* Introduces new topics, and sever

  3. Epitaxy, thin films and superlattices

    International Nuclear Information System (INIS)

    Jagd Christensen, Morten

    1997-05-01

    This report is the result of structural investigations of 3d transition metal superlattices consisting of Fe/V, Cr/Mn, V/Mn and Fe/Mn, and a structural and magnetic study of a series of Ho/Pr alloys. The work includes preparation and characterization of substrates as well as growth of thin films and Fe/V superlattices by molecular beam epitaxy, including in-situ characterization by reflection high energy electron diffraction and Auger electron spectroscopy. Structural characterization has been done by x-ray diffraction and neutron diffraction. The x-ray diffraction experiments have been performed on the rotating copper anode at Risoe, and at synchrotron facilities in Hamburg and Brookhaven, and the neutron scattering was done at the Danish research reactor DR3 at Risoe. In addition to longitudinal scans, giving information about the structural parameters in the modulation direction, non-specular scans were also performed. This type of scans gives information about in-plane orientation and lattice parameters. From the analysis, structural information is obtained about lattice parameters, epitaxial strain, coherence lengths and crystallographic orientation for the superlattice systems, except Fe/Mn superlattices, which could not be modelled. For the Ho/Pr alloys, x-ray magnetic scattering was performed, and the crystal and magnetic structure was investigated. (au)

  4. Epitaxy, thin films and superlattices

    Energy Technology Data Exchange (ETDEWEB)

    Jagd Christensen, Morten

    1997-05-01

    This report is the result of structural investigations of 3d transition metal superlattices consisting of Fe/V, Cr/Mn, V/Mn and Fe/Mn, and a structural and magnetic study of a series of Ho/Pr alloys. The work includes preparation and characterization of substrates as well as growth of thin films and Fe/V superlattices by molecular beam epitaxy, including in-situ characterization by reflection high energy electron diffraction and Auger electron spectroscopy. Structural characterization has been done by x-ray diffraction and neutron diffraction. The x-ray diffraction experiments have been performed on the rotating copper anode at Risoe, and at synchrotron facilities in Hamburg and Brookhaven, and the neutron scattering was done at the Danish research reactor DR3 at Risoe. In addition to longitudinal scans, giving information about the structural parameters in the modulation direction, non-specular scans were also performed. This type of scans gives information about in-plane orientation and lattice parameters. From the analysis, structural information is obtained about lattice parameters, epitaxial strain, coherence lengths and crystallographic orientation for the superlattice systems, except Fe/Mn superlattices, which could not be modelled. For the Ho/Pr alloys, x-ray magnetic scattering was performed, and the crystal and magnetic structure was investigated. (au) 14 tabs.; 58 ills., 96 refs.

  5. Film Music. Factfile No. 8.

    Science.gov (United States)

    Elsas, Diana, Ed.; And Others

    Organizations listed here with descriptive information include film music clubs and music guilds and associations. These are followed by a representative list of schools offering film music and/or film sound courses. Sources are listed for soundtrack recordings, sound effects/production music, films on film music, and oral history programs. The…

  6. Film boiling heat transfer and vapour film collapse for various geometries

    International Nuclear Information System (INIS)

    Jouhara, H.I.; Axcell, B.P.

    2005-01-01

    Full text of publication follows: Film boiling heat transfer has application to the safe operation of water-cooled nuclear reactors under fault conditions and it has been studied using nickel-plated copper specimens in transient and steady state experiments. In the transient tests the specimens were held in a water flow; in the steady state investigation a specimen was mounted in an essentially quiescent pool of water. The transient investigation was conducted on two spheres with different diameters, two cylindrical specimens of different lengths in parallel flow, a short cylinder in cross flow and two flat plates with different lengths. The heat transfer coefficient, vapour film thickness (which was estimated from the heat transfer coefficient) and heat flux followed a similar behaviour with changing experimental conditions for all specimens studied. The heat transfer coefficient increased and the vapour film thickness and heat flux decreased as the specimen temperature decreased. As the water subcooling increased the heat transfer coefficient and the heat flux increased while the vapour film thickness decreased. The water velocity was found to have little influence on the film boiling heat transfer results except for the short cylinder in cross flow. The sphere diameter was found to affect the heat transfer results; the heat transfer coefficient and the heat flux were larger, for the larger sphere. No significant effect of the cylinder length on the heat transfer data was observed. However, the heat transfer coefficient was higher (and the average vapour film thinner) for the longer plate than for the shorter plate. Three vapour/liquid interface types were observed namely: 'smooth', 'rippled' and 'turbulent' depending largely on specimen and water temperatures. For all specimens, the maximum heat transfer coefficient, minimum heat flux and minimum film boiling temperature, occurring just before vapour film collapse, were found to increase as the water subcooling

  7. Antikken på film

    DEFF Research Database (Denmark)

    Krasilnikoff, Jens

    2012-01-01

    Review af forskning om den græsk-romerske oldtid på film. Dertil en skitse til videre arbejde med antikken på film ud fra et historiefagligt og kulturhistorisk udgangspunkt.......Review af forskning om den græsk-romerske oldtid på film. Dertil en skitse til videre arbejde med antikken på film ud fra et historiefagligt og kulturhistorisk udgangspunkt....

  8. Lars von Triers film

    DEFF Research Database (Denmark)

    Nielsen, Lisbeth Overgaard

    2007-01-01

    Afhandlingen undersøger Lars von Triers filmæstetik, som den kommer til udtryk i spillefilmene fra perioden 1984-2007. Afhandlingen analyserer de enkelte films stil, virkningsstrategi og betydningsdannelse.......Afhandlingen undersøger Lars von Triers filmæstetik, som den kommer til udtryk i spillefilmene fra perioden 1984-2007. Afhandlingen analyserer de enkelte films stil, virkningsstrategi og betydningsdannelse....

  9. Film sheet cassette

    International Nuclear Information System (INIS)

    1981-01-01

    A novel film sheet cassette is described for handling CAT photographic films under daylight conditions and facilitating their imaging. A detailed description of the design and operation of the cassette is given together with appropriate illustrations. The resulting cassette is a low-cost unit which is easily constructed and yet provides a sure light-tight seal for the interior contents of the cassette. The individual resilient fingers on the light-trap permit the ready removal of the slide plate for taking pictures. The stippled, non-electrostatic surface of the pressure plate ensures an air layer and free slidability of the film for removal and withdrawal of the film sheet. The advantage of the daylight system is that a darkroom need not be used for inserting and removing the film in and out of the cassette resulting in a considerable time saving. (U.K.)

  10. Thin films for precision optics

    International Nuclear Information System (INIS)

    Araujo, J.F.; Maurici, N.; Castro, J.C. de

    1983-01-01

    The technology of producing dielectric and/or metallic thin films for high precision optical components is discussed. Computer programs were developed in order to calculate and register, graphically, reflectance and transmittance spectra of multi-layer films. The technology of vacuum evaporation of several materials was implemented in our thin-films laboratory; various films for optics were then developed. The possibility of first calculate film characteristics and then produce the film is of great advantage since it reduces the time required to produce a new type of film and also reduces the cost of the project. (C.L.B.) [pt

  11. Thin-film photovoltaic technology

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, R.N. [National Renewable Energy Laboratory, Golden, CO (United States)

    2010-07-01

    The high material and processing costs associated with single-crystal and polycrystalline silicon wafers that are commonly used in photovoltaic cells render these modules expensive. This presentation described thin-film solar cell technology as a promising alternative to silicon solar cell technology. Cadmium telluride (CdTe) thin films along with copper, indium, gallium, and selenium (CIGS) thin films have become the leaders in this field. Their large optical absorption coefficient can be attributed to a direct energy gap that allows the use of thin layers (1-2 {mu}m) of active material. The efficiency of thin-film solar cell devices based on CIGS is 20 per cent, compared to 16.7 per cent for thin-film solar cell devices based on CdTe. IBM recently reported an efficiency of 9.7 per cent for a new type of inorganic thin-film solar cell based on a Cu{sub 2}ZnSn(S, Se){sub 4} compound. The efficiency of an organic thin-film solar cell is 7.9 per cent. This presentation included a graph of PV device efficiencies and discussed technological advances in non-vacuum deposited, CIGS-based thin-film solar cells. 1 fig.

  12. Longitudinal Electroproduction of Charged Pions from

    International Nuclear Information System (INIS)

    David Gaskell; Abdellah Ahmidouch; Pawel Ambrozewicz; H. Anklin; John Arrington; K. Assamagan; Steven Avery; Kevin Bailey; Oliver K. Baker; Shelton Beedoe; Elizabeth Beise; Herbert Breuer; D. S. Brown; Roger Carlini; Jinseok Cha; Nicholas Chant; Anthony Cowley; Samuel Danagoulian; D. De Schepper; Jim Dunne; Dipangkar Dutta; Rolf Ent; Liping Gan; Ashot Gasparian; Donald Geesaman; Ron Gilman; Charles Glashausser; Paul Gueye; M. Harvey; O. Hashimoto; Wendy Hinton; G. Hofman; Ceasar Jackson; Hal Jackson; Cynthia Keppel; Ed Kinney; Doug Koltenuk; G. Kyle; Allison Lung; David Mack; D. McKee; Joseph Mitchell; Hamlet Mkrtchyan; B. Mueller; Gabriel Niculescu; Ioana Niculescu; Tom O'Neill; V. Papavassiliou; Dave Potterveld; Juerg Reinhold; Philip Roos; Reyad Sawafta; Ralph Segel; Stepan Stepanyan; Vardan Tadevosyan; T. Takahashi; Liguang Tang; B. Terburg; D. Van Westrum; J. Volmer; T. P. Welch; Stephen Wood; Lulin Yuan; Ben Zeidman; Beni Zihlmann

    2001-01-01

    Separated longitudinal and transverse cross sections for charged pion electroproduction from 1 H, 2 H, and 3 He were measured at Q 2 = 0.4 (GeV/c) 2 for two values of the invariant mass, (bar W) = 1.15 GeV and (bar W) = 1.60 GeV, in a search for a mass dependence which would signal the effect of nuclear pions. This is the first such study that includes recoil momenta significantly above the Fermi surface. The longitudinal cross section, if dominated by the pion-pole process, should be sensitive to nuclear pion currents. Comparisons of the longitudinal cross section target ratios to a quasifree calculation reveal a significant suppression in 3> He at (bar W) = 1.60 GeV. The (bar W) = 1.15 GeV results are consistent with simple estimates of the effect of nuclear pion currents, but are also consistent with pure quasifree production

  13. Film selection in medical radiology

    International Nuclear Information System (INIS)

    Bor, Dogan

    1988-01-01

    Importing of medical imaging films is the responsibility of Turkish Red Croscend, but some institutions have currently started to import their own films. Because of the different resources in individual departments throughout Turkey, a general purpose medical film is imported by Turkish Red Croscend. This kind of film has the advantage to tolerate some technical faults related to the exposure, dark room and processing conditions and still reveals the necessary image quality. In addition to general purpose film, many companies produce special used films which improve some film characteristics in order to have a better image. The initial results of a project already started by Turkish Atomic Energy Authority showed that some other technical reasons prevent obtaining films with optimum quality. The film is the last step of diagnostic procedure and not only gives necessary clinical information, but also visualizes all the problems related to the lock of the calibration of X-ray system and dark room processing conditions. Because of these reasons, many people hold the film responsible for every technical problem. During the selection of the best film among the different companies, institutions have to fulfill some prerequisites at the beginning and than evaluate the quantitative results obtained from measurements according to their clinical purposes. It is the subject of this paper to show how to use film parameter as a comparison to different types of films measured with light sensitometry method. The dark room and processing problems which adversely effect the results are also given. The requirements for the best film selection both for general and special purposes are also evaluated. The extent of this paper is limited only to films using radiology and does not cover the types used in other imaging areas

  14. Evaluating Boy Scout Geology Education, A Pilot Study

    Science.gov (United States)

    Hintz, R. S.; Thomson, B.

    2008-12-01

    This study investigated geology knowledge acquisition by Boy Scouts through use of the Boy Scout Geology Merit Handbook. In this study, boys engaged in hands-on interactive learning following the requirements set forth in the Geology Merit Badge Handbook. The purposes of this study were to determine the amount of geology content knowledge engendered in adolescent males through the use of the Geology Merit Badge Handbook published by the Boy Scouts of America; to determine if single sex, activity oriented, free-choice learning programs can be effective in promoting knowledge development in young males; and to determine if boys participating in the Scouting program believed their participation helped them succeed in school. Members of a local Boy Scout Troop between the ages of 11 and 18 were invited to participate in a Geology Merit Badge program. Boys who did not already possess the badge were allowed to self-select participation. The boys' content knowledge of geology, rocks, and minerals was pre- and post-tested. Boys were interviewed about their school and Scouting experiences; whether they believed their Scouting experiences and work in Merit Badges contributed to their success in school. Contributing educational theories included single-sex education, informal education with free-choice learning, learning styles, hands-on activities, and the social cognitive theory concept of self-efficacy. Boys who completed this study seemed to possess a greater knowledge of geology than they obtained in school. If boys who complete the Boy Scout Geology Merit Badge receive additional geological training, their field experiences and knowledge acquired through this learning experience will be beneficial, and a basis for continued scaffolding of geologic knowledge.

  15. Religion og film

    DEFF Research Database (Denmark)

    Hvithamar, Annika; Eskjær, Mikkel Fugl

    2007-01-01

    Artiklen søger at stipulere en ramme for analyse af religion og film. Dels ved at række ud over den blotte konstatering af tilstedeværelse af religiøse elementer i film, dels ved at anslå en række temaer, der kan anvendes til analyse af sådanne film (individualisering, (de-)sekularisering, banal...

  16. High-quality AlN films grown on chemical vapor-deposited graphene films

    Directory of Open Access Journals (Sweden)

    Chen Bin-Hao

    2016-01-01

    Full Text Available We report the growth of high-quality AlN films on graphene. The graphene films were synthesized by CVD and then transferred onto silicon substrates. Epitaxial aluminum nitride films were deposited by DC magnetron sputtering on both graphene as an intermediate layer and silicon as a substrate. The structural characteristics of the AlN films and graphene were investigated. Highly c-axis-oriented AlN crystal structures are investigated based on the XRDpatterns observations.

  17. Rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC)

    Science.gov (United States)

    Li, Xiuling; Huang, Wen

    2015-04-28

    A rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC) comprises a multilayer sheet in a rolled configuration comprising multiple turns about a longitudinal axis, where the multilayer sheet comprises a conductive pattern layer on a strain-relieved layer. The conductive pattern layer comprises a first conductive film and a second conductive film separated from the first conductive film in a rolling direction. In the rolled configuration, the first conductive film surrounds the longitudinal axis, and the second conductive film surrounds the first conductive film. The first conductive film serves as a signal line and the second conductive film serves as a conductive shield for the rolled-up transmission line structure.

  18. Longitudinal Muscle Dysfunction in Achalasia Esophagus and Its Relevance

    OpenAIRE

    Mittal, Ravinder K; Hong, Su Jin; Bhargava, Valmik

    2013-01-01

    Muscularis propria of the esophagus is organized into circular and longitudinal muscle layers. Goal of this review is to summarize the role of longitudinal muscle in physiology and pathophysiology of esophageal sensory and motor function. Simultaneous manometry and ultrasound imaging that measure circular and longitudinal muscle contraction respectively reveal that during peristalsis 2 layers of the esophagus contract in perfect synchrony. On the other hand, during transient relaxation of the...

  19. "Kuleshov on Film": A Spectator-Centered Film Theory.

    Science.gov (United States)

    Curran, Trisha

    This paper describes some of the theories of cinematography of Soviet film theorist and filmmaker Lev Kuleshov. It points out that for him, film was communication portraying people's activities emanating from the environment. It explains that he was especially interested in audience response, particularly that of the proletariat, and that he felt…

  20. Radiochromic film dosimetry. Considerations on precision and accuracy for EBT2 and EBT3 type films

    Energy Technology Data Exchange (ETDEWEB)

    Dreindl, Ralf [Medical Univ. of Vienna/Vienna General Hospital (Austria). Dept. of Radiooncology; EBG MedAustron GmbH, Wiener Neustadt (Austria); Georg, Dietmar; Stock, Markus [Medical Univ. of Vienna/Vienna General Hospital (Austria). Dept. of Radiooncology; Medical Univ. of Vienna (Austria). Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology

    2014-09-01

    Gafchromic {sup registered} EBT2 film is a widely used dosimetric tool for quality assurance in radiation therapy. In 2012 EBT3 was presented as a replacement for EBT2 films. The symmetric structure of EBT3 films to reduce face-up/down dependency as well as the inclusion of a matte film surface to frustrate Newton Ring artifacts present the most prominent improvements of EBT3 films. The aim of this study was to investigate the characteristics of EBT3 films, to benchmark the films against the known EBT2-features and to evaluate the dosimetric behavior over a time period greater than 6 months. All films were irradiated to clinical photon beams (6MV, 10MV and 18MV) on an Elekta Synergy Linac equipped with a Beam Modulator MLC in solid water phantom slabs. Film digitalization was done with a flatbed transparency scanner (Type Epson Expression 1680 Pro). MATLAB {sup registered} was used for further statistical calculations and image processing. The investigations on post-irradiation darkening, film orientation, film uniformity and energy dependency resulted in negligible differences between EBT2 and EBT3 film. A minimal improvement in face-up/down dependence was found for EBT3. The matte film surface of EBT3 films turned out to be a practical feature as Newton rings could be eliminated completely. Considering long-term behavior (> 6 months) a shift of the calibration curve for EBT2 and EBT3 films due to changes in the dynamic response of the active component was observed. In conclusion, the new EBT3 film yields comparable results to its predecessor EBT2. The general advantages of radiochromic film dosimeters are completed by high film homogeneity, low energy dependence for the observed energy range and a minimized face-up/down dependence. EBT2 dosimetry-protocols can also be used for EBT3 films, but the inclusion of periodical recalibration-interval (e.g. once a quarter) is recommended for protocols of both film generations. (orig.)

  1. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.

    Science.gov (United States)

    Dreindl, Ralf; Georg, Dietmar; Stock, Markus

    2014-05-01

    Gafchromic® EBT2 film is a widely used dosimetric tool for quality assurance in radiation therapy. In 2012 EBT3 was presented as a replacement for EBT2 films. The symmetric structure of EBT3 films to reduce face-up/down dependency as well as the inclusion of a matte film surface to frustrate Newton Ring artifacts present the most prominent improvements of EBT3 films. The aim of this study was to investigate the characteristics of EBT3 films, to benchmark the films against the known EBT2-features and to evaluate the dosimetric behavior over a time period greater than 6 months. All films were irradiated to clinical photon beams (6 MV, 10 MV and 18 MV) on an Elekta Synergy Linac equipped with a Beam Modulator MLC in solid water phantom slabs. Film digitalization was done with a flatbed transparency scanner (Type Epson Expression 1680 Pro). MATLAB® was used for further statistical calculations and image processing. The investigations on post-irradiation darkening, film orientation, film uniformity and energy dependency resulted in negligible differences between EBT2 and EBT3 film. A minimal improvement in face-up/down dependence was found for EBT3. The matte film surface of EBT3 films turned out to be a practical feature as Newton rings could be eliminated completely. Considering long-term behavior (> 6 months) a shift of the calibration curve for EBT2 and EBT3 films due to changes in the dynamic response of the active component was observed. In conclusion, the new EBT3 film yields comparable results to its predecessor EBT2. The general advantages of radiochromic film dosimeters are completed by high film homogeneity, low energy dependence for the observed energy range and a minimized face-up/down dependence. EBT2 dosimetry-protocols can also be used for EBT3 films, but the inclusion of periodical recalibration-interval (e.g. once a quarter) is recommended for protocols of both film generations. Copyright © 2013. Published by Elsevier GmbH.

  2. Radiochromic film dosimetry. Considerations on precision and accuracy for EBT2 and EBT3 type films

    International Nuclear Information System (INIS)

    Dreindl, Ralf; Georg, Dietmar; Stock, Markus; Medical Univ. of Vienna

    2014-01-01

    Gafchromic registered EBT2 film is a widely used dosimetric tool for quality assurance in radiation therapy. In 2012 EBT3 was presented as a replacement for EBT2 films. The symmetric structure of EBT3 films to reduce face-up/down dependency as well as the inclusion of a matte film surface to frustrate Newton Ring artifacts present the most prominent improvements of EBT3 films. The aim of this study was to investigate the characteristics of EBT3 films, to benchmark the films against the known EBT2-features and to evaluate the dosimetric behavior over a time period greater than 6 months. All films were irradiated to clinical photon beams (6MV, 10MV and 18MV) on an Elekta Synergy Linac equipped with a Beam Modulator MLC in solid water phantom slabs. Film digitalization was done with a flatbed transparency scanner (Type Epson Expression 1680 Pro). MATLAB registered was used for further statistical calculations and image processing. The investigations on post-irradiation darkening, film orientation, film uniformity and energy dependency resulted in negligible differences between EBT2 and EBT3 film. A minimal improvement in face-up/down dependence was found for EBT3. The matte film surface of EBT3 films turned out to be a practical feature as Newton rings could be eliminated completely. Considering long-term behavior (> 6 months) a shift of the calibration curve for EBT2 and EBT3 films due to changes in the dynamic response of the active component was observed. In conclusion, the new EBT3 film yields comparable results to its predecessor EBT2. The general advantages of radiochromic film dosimeters are completed by high film homogeneity, low energy dependence for the observed energy range and a minimized face-up/down dependence. EBT2 dosimetry-protocols can also be used for EBT3 films, but the inclusion of periodical recalibration-interval (e.g. once a quarter) is recommended for protocols of both film generations. (orig.)

  3. [Oral films as perspective dosage form].

    Science.gov (United States)

    Walicová, Veronika; Gajdziok, Jan

    Oral films, namely buccal mucoadhesive films and orodispersible films represent innovative formulations for administration of a wide range of drugs. Oral films show many advantageous properties and are intended for systemic drug delivery or for local treatment of the oral mucosa. In both cases, the film represents a thin layer, which could be intended to adhere to the oral mucosa by means of mucoadhesion; or to rapid dissolution and subsequent swallowing without the need of liquid intake, in the case of orodispersible films. Main constitutive excipients are film-forming polymers, which must in the case of mucoadhesive forms remain on the mucosa within the required time interval. Oral films are currently available on the pharmaceutical market and could compete with conventional oral dosage forms in the future. oral cavity oral films buccal mucoadhesive films orodispersible films film-forming polymers.

  4. Heat production: Longitudinal versus torsional phacoemulsification.

    Science.gov (United States)

    Han, Young Keun; Miller, Kevin M

    2009-10-01

    To compare the heat production of longitudinal versus torsional phacoemulsification under strict laboratory test conditions. Department of Ophthalmology, David Geffen School of Medicine at UCLA, and Jules Stein Eye Institute, Los Angeles, California, USA. Two Infiniti phacoemulsification handpieces were inserted into silicone test chambers filled with a balanced salt solution and imaged serially using a thermal camera. Incision compression was simulated by suspending 25.3 g weights from the silicone chambers. To simulate occlusion of the phacoemulsification tip, the aspiration line was clamped. Peak temperatures were measured 0, 10, 30, 60, and 120 seconds after the commencement of continuous ultrasound power. The 2 handpieces, operating exclusively in longitudinal or torsional modes, were compared 3 ways: (1) using the same power displayed on the instrument console, (2) using identical stroke lengths, and (3) using the same applied energy, a product of stroke length and frequency. For all 3 comparisons, torsional phacoemulsification resulted in lower temperatures at each time point. At the same displayed power setting, the scenario most familiar to cataract surgeons, longitudinal phacoemulsification elevated temperatures up to 41.5 degrees C more than torsional phacoemulsification. Torsional phacoemulsification generated less heat than longitudinal phacoemulsification in all 3 comparison tests. Lower operating temperatures indicate lower heat generation within the same volume of fluid, and this may provide additional thermal protection during cataract surgery.

  5. Evolution of optical constants of silicon dioxide on silicon from ultrathin films to thick films

    Energy Technology Data Exchange (ETDEWEB)

    Cai Qingyuan; Zheng Yuxiang; Mao Penghui; Zhang Rongjun; Zhang Dongxu; Liu Minghui; Chen Liangyao, E-mail: yxzheng@fudan.edu.c [Key Laboratory of Micro and Nano Photonic Structures, Ministry of Education, Department of Optical Science and Engineering, Fudan University, Shanghai 200433 (China)

    2010-11-10

    A series of SiO{sub 2} films with thickness range 1-600 nm have been deposited on crystal silicon (c-Si) substrates by electron beam evaporation (EBE) method. Variable-angle spectroscopic ellipsometry (VASE) in combination with a two-film model (ambient-oxide-interlayer substrate) was used to determine the optical constants and thicknesses of the investigated films. The refractive indices of SiO{sub 2} films thicker than 60 nm are close to those of bulk SiO{sub 2}. For the thin films deposited at the rate of {approx}1.0 nm s{sup -1}, the refractive indices increase with decreasing thickness from {approx}60 to {approx}10 nm and then drop sharply with decreasing thickness below {approx}10 nm. However, for thin films deposited at the rates of {approx}0.4 and {approx}0.2 nm s{sup -1}, the refractive indices monotonically increase with decreasing thickness below 60 nm. The optical constants of the ultrathin film depend on the morphology of the film, the stress exerted on the film, as well as the stoichiometry of the oxide film.

  6. Evolution of optical constants of silicon dioxide on silicon from ultrathin films to thick films

    International Nuclear Information System (INIS)

    Cai Qingyuan; Zheng Yuxiang; Mao Penghui; Zhang Rongjun; Zhang Dongxu; Liu Minghui; Chen Liangyao

    2010-01-01

    A series of SiO 2 films with thickness range 1-600 nm have been deposited on crystal silicon (c-Si) substrates by electron beam evaporation (EBE) method. Variable-angle spectroscopic ellipsometry (VASE) in combination with a two-film model (ambient-oxide-interlayer substrate) was used to determine the optical constants and thicknesses of the investigated films. The refractive indices of SiO 2 films thicker than 60 nm are close to those of bulk SiO 2 . For the thin films deposited at the rate of ∼1.0 nm s -1 , the refractive indices increase with decreasing thickness from ∼60 to ∼10 nm and then drop sharply with decreasing thickness below ∼10 nm. However, for thin films deposited at the rates of ∼0.4 and ∼0.2 nm s -1 , the refractive indices monotonically increase with decreasing thickness below 60 nm. The optical constants of the ultrathin film depend on the morphology of the film, the stress exerted on the film, as well as the stoichiometry of the oxide film.

  7. Fabrication of nitrogen-containing diamond-like carbon film by filtered arc deposition as conductive hard-coating film

    Science.gov (United States)

    Iijima, Yushi; Harigai, Toru; Isono, Ryo; Imai, Takahiro; Suda, Yoshiyuki; Takikawa, Hirofumi; Kamiya, Masao; Taki, Makoto; Hasegawa, Yushi; Tsuji, Nobuhiro; Kaneko, Satoru; Kunitsugu, Shinsuke; Habuchi, Hitoe; Kiyohara, Shuji; Ito, Mikio; Yick, Sam; Bendavid, Avi; Martin, Phil

    2018-01-01

    Diamond-like carbon (DLC) films, which are amorphous carbon films, have been used as hard-coating films for protecting the surface of mechanical parts. Nitrogen-containing DLC (N-DLC) films are expected as conductive hard-coating materials. N-DLC films are expected in applications such as protective films for contact pins, which are used in the electrical check process of integrated circuit chips. In this study, N-DLC films are prepared using the T-shaped filtered arc deposition (T-FAD) method, and film properties are investigated. Film hardness and film density decreased when the N content increased in the films because the number of graphite structures in the DLC film increased as the N content increased. These trends are similar to the results of a previous study. The electrical resistivity of N-DLC films changed from 0.26 to 8.8 Ω cm with a change in the nanoindentation hardness from 17 to 27 GPa. The N-DLC films fabricated by the T-FAD method showed high mechanical hardness and low electrical resistivity.

  8. Longitudinal magnetoresistance and magnototermopower in Bi nanowires

    International Nuclear Information System (INIS)

    Para, G.

    2011-01-01

    Full text: The galvanomagnetic effect of single crystals Bi nanowires have been studied in longitudinal magnetic fields up to 14 T. The influence of diameters, temperature and deformation extension on the longitudinal magnetoresistance and magnetotermopower (H||I, H||ΔT) of bismuth nanowires is studied. Elastic deformation measurements were conducted at maximum relative elongation 2 %. For the first time have been investigated the magnetotermopower of Bi nanowires with d=45 nm. Essentially non monotonic dependence H max on temperature in longitudinal thermopower in wires with d=45-60 nm is found out. Such difference in behavior of maximum on R(H) and on α(H) in wires with d<100nm says that the behavior of resistance is caused by other mechanism, then thermopower. (author)

  9. Ferroelectric ultrathin perovskite films

    Science.gov (United States)

    Rappe, Andrew M; Kolpak, Alexie Michelle

    2013-12-10

    Disclosed herein are perovskite ferroelectric thin-film. Also disclosed are methods of controlling the properties of ferroelectric thin films. These films can be used in a variety materials and devices, such as catalysts and storage media, respectively.

  10. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC[reg] film

    International Nuclear Information System (INIS)

    Lynch, Bart D.; Kozelka, Jakub; Ranade, Manisha K.; Li, Jonathan G.; Simon, William E.; Dempsey, James F.

    2006-01-01

    In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC[reg] EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson Expression 1680 CCD array scanner, and a Microtek ScanMaker i900 CCD array scanner. For the two scanners we assessed the variation in optical density (OD) of GAFCHROMIC EBT film with scanning bed position, angular rotation of the film with respect to the scan line direction, and temperature inside the scanner due to repeated scanning. Scanning uniform radiochromic films demonstrated a distinct bowing effect in profiles in the direction of the CCD array with a nonuniformity of up to 17%. Profiles along a direction orthogonal to the CCD array demonstrated a 7% variation. A strong angular dependence was found in measurements made with the flatbed scanners; the effect could not be reproduced with the spot densitometer. An IMRT quality assurance film was scanned twice rotating the film 90 deg. between the scans. For films scanned on the Epson scanner, up to 12% variation was observed in unirradiated EBT films rotated between 0 deg. and 90 deg. , which decreased to approximately 8% for EBT films irradiated to 300 cGy. Variations of up to 80% were observed for films scanned with the Microtek scanner. The scanners were found to significantly increase the film temperature with repeated scanning. Film temperature between 18 and 33 deg. C caused OD changes of approximately 7%. Considering these effects, we recommend adherence to a strict scanning protocol that includes: maintaining the orientation of films scanned on flatbed scanners, limiting scanning to the central portion of the scanner bed, and limiting the number of consecutive scans to minimize changes in OD caused by film heating

  11. Characteristics of ITO films with oxygen plasma treatment for thin film solar cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Seob [Department of Photoelectronics Information, Chosun College of Science and Technology, Gwangju (Korea, Republic of); Kim, Eungkwon [Digital Broadcasting Examination, Korean Intellectual Property Office, Daejeon, Suwon 440-746 (Korea, Republic of); Hong, Byungyou [School of Electronic and Electrical Engineering, Sungkyunkwan University, Cheoncheon-dong, 300, Jangan-gu, Suwon 440-746 (Korea, Republic of); Lee, Jaehyoeng, E-mail: jaehyeong@skku.edu [School of Electronic and Electrical Engineering, Sungkyunkwan University, Cheoncheon-dong, 300, Jangan-gu, Suwon 440-746 (Korea, Republic of)

    2013-12-15

    Graphical abstract: The effect of O{sub 2} plasma treatment on the surface and the work function of ITO films. - Highlights: • ITO films were prepared on the glass substrate by RF magnetron sputtering method. • Effects of O{sub 2} plasma treatment on the properties of ITO films were investigated. • The work function of ITO film was changed from 4.67 to 5.66 eV by plasma treatment. - Abstract: The influence of oxygen plasma treatment on the electro-optical and structural properties of indium-tin-oxide films deposited by radio frequency magnetron sputtering method were investigated. The films were exposed at different O{sub 2} plasma powers and for various durations by using the plasma enhanced chemical vapor deposition (PECVD) system. The resistivity of the ITO films was almost constant, regardless of the plasma treatment conditions. Although the optical transmittance of ITO films was little changed by the plasma power, the prolonged treatment slightly increased the transmittance. The work function of ITO film was changed from 4.67 eV to 5.66 eV at the plasma treatment conditions of 300 W and 60 min.

  12. Host thin films incorporating nanoparticles

    Science.gov (United States)

    Qureshi, Uzma

    The focus of this research project was the investigation of the functional properties of thin films that incorporate a secondary nanoparticulate phase. In particular to assess if the secondary nanoparticulate material enhanced a functional property of the coating on glass. In order to achieve this, new thin film deposition methods were developed, namely use of nanopowder precursors, an aerosol assisted transport technique and an aerosol into atmospheric pressure chemical vapour deposition system. Aerosol assisted chemical vapour deposition (AACVD) was used to deposit 8 series of thin films on glass. Five different nanoparticles silver, gold, ceria, tungsten oxide and zinc oxide were tested and shown to successfully deposit thin films incorporating nanoparticles within a host matrix. Silver nanoparticles were synthesised and doped within a titania film by AACVD. This improved solar control properties. A unique aerosol assisted chemical vapour deposition (AACVD) into atmospheric pressure chemical vapour deposition (APCVD) system was used to deposit films of Au nanoparticles and thin films of gold nanoparticles incorporated within a host titania matrix. Incorporation of high refractive index contrast metal oxide particles within a host film altered the film colour. The key goal was to test the potential of nanopowder forms and transfer the suspended nanopowder via an aerosol to a substrate in order to deposit a thin film. Discrete tungsten oxide nanoparticles or ceria nanoparticles within a titanium dioxide thin film enhanced the self-cleaning and photo-induced super-hydrophilicity. The nanopowder precursor study was extended by deposition of zinc oxide thin films incorporating Au nanoparticles and also ZnO films deposited from a ZnO nanopowder precursor. Incorporation of Au nanoparticles within a VO: host matrix improved the thermochromic response, optical and colour properties. Composite VC/TiC and Au nanoparticle/V02/Ti02 thin films displayed three useful

  13. Film models for transport phenomena with fog formation: The classical film model

    NARCIS (Netherlands)

    Brouwers, Jos; Chesters, A.K.

    1992-01-01

    In the present analysis the classical film model (or film theory) is reviewed and extended. First, on the basis of a thorough analysis, the governing equations of diffusion, energy and momentum of a stagnant film are derived and solved. Subsequently, the well-known correction factors for the effect

  14. Film models for transport phenomena with fog formation: the classical film model

    NARCIS (Netherlands)

    Brouwers, H.J.H.; Chesters, A.K.

    1992-01-01

    In the present analysis the classical film model (or film theory) is reviewed and extended. First, on the basis of a thorough analysis, the governing equations of diffusion, energy and momentum of a stagnant film are derived and solved. Subsequently, the well-known correction factors for the effect

  15. Family Porn - the zodiac-film

    DEFF Research Database (Denmark)

    Thorsen, Christian Isak

    2015-01-01

    This article addresses the highly popular Danish Zodiac films, a series of six films made between 1973 and 1978. What was extraordinary about the films was their combination of traditional popular comedy and hard-core porn. Analysing the films� combination of comedy and pornography from a histori......This article addresses the highly popular Danish Zodiac films, a series of six films made between 1973 and 1978. What was extraordinary about the films was their combination of traditional popular comedy and hard-core porn. Analysing the films� combination of comedy and pornography from...

  16. Longitudinal Electron Bunch Diagnostics Using Coherent Transition Radiation

    CERN Document Server

    Mihalcea, Daniel; Happek, Uwe; Regis-Guy Piot, Philippe

    2005-01-01

    The longitudinal charge distribution of electron bunches in the Fermilab A0 photo-injector was determined by using the coherent transition radiation produced by electrons passing through a thin metallic foil. The auto-correlation of the transition radiation signal was measured with a Michelson type interferometer. The response function of the interferometer was determined from measured and simulated power spectra for low electron bunch charge and maximum longitudinal compression. Kramers-Kroning technique was used to determine longitudinal charge distribution. Measurements were performed for electron bunch lengths in the range from 0.3 to 2 ps (rms).

  17. Performance evaluation of a colorimetric hydrazine dosimeter

    Science.gov (United States)

    Brenner, Karen P.; Rose-Pehrsson, Susan L.

    1994-06-01

    A dosimeter for real-time, colorimetric detection of hydrazine in air has been developed. The passive badge consists of a dosimeter card containing a vanillin solution coated on a thin paper substrate. The active patch consists of a thick cellulose substrate coated with a vanillin solution. When placed in a plastic sample holder attached to a personnel pump, up to 5 L/min can be drawn through the active badge substrate. Through a condensation reaction, vanillin reacts with hydrazine to form a colored product that absorbs in the visible region. The hydrazone formed in the reaction is yellow; its intensity is proportional to the dose. When exposed passively to hydrazine, the experimental detection limit is less than 20 ppb-hrs. Extrapolated results indicate a detection limit of less than 5 ppb-hrs for long sampling periods. Actively sampling of hydrazine vapors gives an experimental detection limit of less than 100 ppb-L at a sample rate of 5 L/min. Relative humidity effects on badge response were minor. High humidity enhanced the color development on the vanillin badge; while low humidity had no effect on badge response. Interference testing of the dosimeters revealed a tobacco smoke interference. Preliminary shelf life tests indicated no decrease in sensitivity to hydrazine when stored at room temperature for 6 months.

  18. Multilevel Cross-Dependent Binary Longitudinal Data

    KAUST Repository

    Serban, Nicoleta

    2013-10-16

    We provide insights into new methodology for the analysis of multilevel binary data observed longitudinally, when the repeated longitudinal measurements are correlated. The proposed model is logistic functional regression conditioned on three latent processes describing the within- and between-variability, and describing the cross-dependence of the repeated longitudinal measurements. We estimate the model components without employing mixed-effects modeling but assuming an approximation to the logistic link function. The primary objectives of this article are to highlight the challenges in the estimation of the model components, to compare two approximations to the logistic regression function, linear and exponential, and to discuss their advantages and limitations. The linear approximation is computationally efficient whereas the exponential approximation applies for rare events functional data. Our methods are inspired by and applied to a scientific experiment on spectral backscatter from long range infrared light detection and ranging (LIDAR) data. The models are general and relevant to many new binary functional data sets, with or without dependence between repeated functional measurements.

  19. Film studies the basics

    CERN Document Server

    Villarejo, Amy

    2013-01-01

    Film Studies: The Basics is a compelling guide to the study of cinema in all its forms. This second edition has been thoroughly revised and updated to take account of recent scholarship, the latest developments in the industry and the explosive impact of new technologies. Core topics covered include:   The history, technology and art of cinema Theories of stardom, genre and film-making The movie industry from Hollywood to Bollywood Who does what on a film set   Complete with film stills, end-of-chapter summaries and a substantial glossary, Film Studies: The Basics is the ideal introduction to those new to the study of cinema.

  20. Pyrolyzed thin film carbon

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Liger, Matthieu (Inventor); Harder, Theodore (Inventor); Konishi, Satoshi (Inventor); Miserendino, Scott (Inventor)

    2010-01-01

    A method of making carbon thin films comprises depositing a catalyst on a substrate, depositing a hydrocarbon in contact with the catalyst and pyrolyzing the hydrocarbon. A method of controlling a carbon thin film density comprises etching a cavity into a substrate, depositing a hydrocarbon into the cavity, and pyrolyzing the hydrocarbon while in the cavity to form a carbon thin film. Controlling a carbon thin film density is achieved by changing the volume of the cavity. Methods of making carbon containing patterned structures are also provided. Carbon thin films and carbon containing patterned structures can be used in NEMS, MEMS, liquid chromatography, and sensor devices.

  1. Longitudinal conductivity of LaF3/SrF2 multilayer heterostructures.

    Science.gov (United States)

    Vergentev, Tikhon; Banshchikov, Alexander; Filimonov, Alexey; Koroleva, Ekaterina; Sokolov, Nikolay; Wurz, Marc Christopher

    2016-01-01

    LaF 3 /SrF 2 multilayer heterostructures with thicknesses of individual layers in the range 5-100 nm have been grown on MgO(100) substrates using molecular beam epitaxy. The longitudinal conductivity of the films has been measured using impedance spectroscopy in the frequency range 10 -1 -10 6  Hz and a temperature range 300-570 K. The ionic DC conductivities have been determined from Nyquist impedance diagrams and activation energies from the Arrhenius-Frenkel equation. An increase of the DC conductivity has been observed to accompany decreased layer thickness for various thicknesses as small as 25 nm. The greatest conductivity has been shown for a multilayer heterostructure having thicknesses of 25 nm per layer. The structure has a conductivity two orders of magnitude greater than pure LaF 3 bulk material. The increasing conductivity can be understood as a redistribution of charge carriers through the interface due to differing chemical potentials of the materials, by strong lattice-constant mismatch, and/or by formation of a solid La 1-x Sr x F 3-x solution at the interface during the growth process.

  2. Ellipsometry of anodic film growth

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C.G.

    1978-08-01

    An automated computer interpretation of ellisometer measurements of anodic film growth was developed. Continuous mass and charge balances were used to utilize more fully the time dependence of the ellipsometer data and the current and potential measurements. A multiple-film model was used to characterize the growth of films which proceeds via a dissolution--precipitation mechanism; the model also applies to film growth by adsorption and nucleation mechanisms. The characteristic parameters for film growth describe homogeneous and heterogeneous crystallization rates, film porosities and degree of hydration, and the supersaturation of ionic species in the electrolyte. Additional descriptions which may be chosen are patchwise film formation, nonstoichiometry of the anodic film, and statistical variations in the size and orientation of secondary crystals. Theories were developed to describe the optical effects of these processes. An automatic, self-compensating ellipsometer was used to study the growth in alkaline solution of anodic films on silver, cadmium, and zinc. Mass-transport conditions included stagnant electrolyte and forced convection in a flow channel. Multiple films were needed to characterize the optical properties of these films. Anodic films grew from an electrolyte supersatuated in the solution-phase dissolution product. The degree of supersaturation depended on transport conditions and had a major effect on the structure of the film. Anodic reaction rates were limited by the transport of charge carriers through a primary surface layer. The primary layers on silver, zinc, and cadmium all appeared to be nonstoichiometric, containing excess metal. Diffusion coefficients, transference numbers, and the free energy of adsorption of zinc oxide were derived from ellipsometer measurements. 97 figures, 13 tables, 198 references.

  3. Personnel photographic film dosimetry

    International Nuclear Information System (INIS)

    Keirim-Markus, I.B.

    1981-01-01

    Technology of personnel photographic film dosimetry (PPD) based on the photographic effect of ionizing radiation is described briefly. Kinds of roentgen films used in PPD method are enumerated, compositions of a developer and fixing agents for these films are given [ru

  4. Fingerprints of transverse and longitudinal coupling between induced open quantum dots in the longitudinal magnetoconductance through antidot lattices

    Science.gov (United States)

    Ujevic, Sebastian; Mendoza, Michel

    2010-07-01

    We propose numerical simulations of longitudinal magnetoconductance through a finite antidot lattice located inside an open quantum dot with a magnetic field applied perpendicular to the plane. The system is connected to reservoirs using quantum point contacts. We discuss the relationship between the longitudinal magnetoconductance and the generation of transversal couplings between the induced open quantum dots in the system. The system presents longitudinal magnetoconductance maps with crossovers (between transversal bands) and closings (longitudinal decoupling) of fundamental quantum states related to the open quantum dots induced by the antidot lattice. A relationship is observed between the distribution of antidots and the formed conductance bands, allowing a systematic follow up of the bands as a function of the applied magnetic field and quantum point-contact width. We observed a high conductance intensity [between n and (n+1) quantum of conductance, n=1,2,… ] in the regions of crossover and closing of states. This suggests transversal couplings between the induced open quantum dots of the system that can be modulated by varying both the antidots potential and the quantum point-contact width. A new continuous channel (not expected) is induced by the variation in the contact width and generate Fano resonances in the conductance. These resonances can be manipulated by the applied magnetic field.

  5. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  6. Longitudinal data analysis a handbook of modern statistical methods

    CERN Document Server

    Fitzmaurice, Garrett; Verbeke, Geert; Molenberghs, Geert

    2008-01-01

    Although many books currently available describe statistical models and methods for analyzing longitudinal data, they do not highlight connections between various research threads in the statistical literature. Responding to this void, Longitudinal Data Analysis provides a clear, comprehensive, and unified overview of state-of-the-art theory and applications. It also focuses on the assorted challenges that arise in analyzing longitudinal data. After discussing historical aspects, leading researchers explore four broad themes: parametric modeling, nonparametric and semiparametric methods, joint

  7. More than films and dragon awards

    DEFF Research Database (Denmark)

    Redvall, Eva Novrup

    2012-01-01

    This article discusses how the largest film festival in the Nordic countries, the Göteborg International Film Festival (GIFF), is much more than a setting for bringing quality films to local audiences.With retrospectives, an extensive programme of seminars and master classes, a film lab for upcom......This article discusses how the largest film festival in the Nordic countries, the Göteborg International Film Festival (GIFF), is much more than a setting for bringing quality films to local audiences.With retrospectives, an extensive programme of seminars and master classes, a film lab...

  8. Radiographic film orientation in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Suchowerska, N.; Davison, A.; Drew, J.; Metcalfe, P.

    1996-01-01

    Since the discovery of x-rays, film has been used as a detection medium for radiation. More recently radiographic film has become established as a practical tool for the measurement of dose distribution in radiotherapy. The accuracy and reproducibility of film dosimetry depends on photon energy, processing conditions and film plane orientation. The relationship between photon energy, processing conditions and film dosimetry accuracy has been studied. The role of film plane orientation is still controversial. The current work aims to clarify the effects film plane orientation has on film dosimetry. Poster 205. (author)

  9. Oxide ultrathin films science and technology

    CERN Document Server

    Pacchioni, Gianfranco

    2012-01-01

    A wealth of information in one accessible book. Written by international experts from multidisciplinary fields, this in-depth exploration of oxide ultrathin films covers all aspects of these systems, starting with preparation and characterization, and going on to geometrical and electronic structure, as well as applications in current and future systems and devices. From the Contents: Synthesis and Preparation of Oxide Ultrathin Films Characterization Tools of Oxide Ultrathin Films Ordered Oxide Nanostructures on Metal Surfaces Unusual Properties of Oxides and Other Insulators in the Ultrathin Limit Silica and High-K Dielectrics Thin Films in Microelectronics Oxide Passive Films and Corrosion Protection Oxide Films as Catalytic Materials and as Models of Real Catalysts Oxide Films in Spintronics Oxide Ultrathin Films in Solid Oxide Fuel Cells Transparent Conducting and Chromogenic Oxide Films as Solar Energy Materials Oxide Ultrathin Films in Sensor Applications Ferroelectricity in Ultrathin Film Capacitors T...

  10. Variable selection and estimation for longitudinal survey data

    KAUST Repository

    Wang, Li

    2014-09-01

    There is wide interest in studying longitudinal surveys where sample subjects are observed successively over time. Longitudinal surveys have been used in many areas today, for example, in the health and social sciences, to explore relationships or to identify significant variables in regression settings. This paper develops a general strategy for the model selection problem in longitudinal sample surveys. A survey weighted penalized estimating equation approach is proposed to select significant variables and estimate the coefficients simultaneously. The proposed estimators are design consistent and perform as well as the oracle procedure when the correct submodel was known. The estimating function bootstrap is applied to obtain the standard errors of the estimated parameters with good accuracy. A fast and efficient variable selection algorithm is developed to identify significant variables for complex longitudinal survey data. Simulated examples are illustrated to show the usefulness of the proposed methodology under various model settings and sampling designs. © 2014 Elsevier Inc.

  11. Magnetic field of longitudinal gradient bend

    Science.gov (United States)

    Aiba, Masamitsu; Böge, Michael; Ehrlichman, Michael; Streun, Andreas

    2018-06-01

    The longitudinal gradient bend is an effective method for reducing the natural emittance in light sources. It is, however, not a common element. We have analyzed its magnetic field and derived a set of formulae. Based on the derivation, we discuss how to model the longitudinal gradient bend in accelerator codes that are used for designing electron storage rings. Strengths of multipole components can also be evaluated from the formulae, and we investigate the impact of higher order multipole components in a very low emittance lattice.

  12. Film beyond boundaries: film, migrant narratives and other media

    Directory of Open Access Journals (Sweden)

    Anelise Reich Corseuil

    2006-04-01

    Full Text Available The articles here presented are representative of the debates about the various transformational aspects of film studies, fostering the discussion about the transformations and interactions between national and international narrative forms, the interrelations between film and literature, and film with other media. The critical perspectives here presented range from an emphasis on cultural materialism, dialogism, reception theory, deconstructionism, narrative studies to film aesthetics or film genre, and can be grouped in three major interrelated areas of film studies: adaptation studies, representation and aesthetics, and film and other media. All of them enable a critical perspective as regards the fluidity of the boundaries separating film from other media, such as literature, television, DVDs, and video games, as newer narrative forms that are incorporated by film, and the transformations in terms of aesthetics and forms of representation in contemporary film and media (the transgeneric nature of film, the interrelations between national and international cinemas, and the demands for a broader perception of the overwhelming mediations of the image in our contemporary society. Moreover, the articles are inserted within recent critical debates on adaptation, digital media and national and transnational cinema (Naremore, Sobchack, Druckery and Williams. All articles combine important theoretical concerns with the analysis of specific films. Robert Stam's “Teoria e Prática da Adaptação: da Fidelidade à Intertextualidade” (“Theory and the practice of adaptation: from fidelity to intertextuality” offers a rich perspective on the issue of adaptation in its relationship with critical theory. He analyses the changing critical views on adaptation, which go from the priority given to the canonic literary text, as an origin, to a more fluid, intertextual and dialogical approach to film adaptation. Drawing from Bakhtin's concept of dialogism

  13. Shanghai and Globalization through the Lens of Film Noir: Lou Ye’s 2000 Film, Suzhou River

    Directory of Open Access Journals (Sweden)

    Hongwei Lu

    2010-10-01

    Full Text Available In the 1990s, the film industry in China decentralized with the bankruptcy of the state-owned studio system. Privatized independent film companies took over where the government had left off and a more independent film culture emerged. Although obstacles such as political censorship, financial pressures, and Hollywood infiltration were still in the way for Chinese filmmakers, privatization of the film industry was under way. As a result of this process, new film productions of controversial subject matter came into being. In 1998 one of China’s first independent film production companies—Dream Factory—was founded. Dream Factory’s first production, in association with Berlin-based German producer Philippe Bober, was the 'Suzhou River, 'directed by its founder Lou Ye'.'1 The 2000 film, though winning prizes at international film festivals such as the Rotterdam Film Festival and the Paris Film Festival, has been banned by the Chinese government since its production.

  14. thin films

    Indian Academy of Sciences (India)

    microscopy (SEM) studies, respectively. The Fourier transform ... Thin films; chemical synthesis; hydrous tin oxide; FTIR; electrical properties. 1. Introduction ... dehydrogenation of organic compounds (Hattori et al 1987). .... SEM images of (a) bare stainless steel and (b) SnO2:H2O thin film on stainless steel substrate at a ...

  15. Into films

    DEFF Research Database (Denmark)

    Tan, Ed S.; Doicaru, Miruna M.; Hakemulder, Frank

    2017-01-01

    Most film viewers know the experience of being deeply absorbed in the story of a popular film. It seems that at such moments they lose awareness of watching a movie. And yet it is highly unlikely that they completely ignore the fact that they watch a narrative and technological construction. Perh...

  16. Demagnetization in photomagnetic films

    Energy Technology Data Exchange (ETDEWEB)

    Pajerowski, Daniel M., E-mail: daniel@pajerowski.com [NIST Center for Neutron Research, Gaithersburg, Maryland 20899 (United States); Hallock, Scott J. [NIST Center for Neutron Research, Gaithersburg, Maryland 20899 (United States); Winston Churchill High School, Potomac, Maryland 20854 (United States)

    2012-05-15

    We present a model for demagnetization in photomagnetic films, and investigate different regimes for the magnetizing process using finite element analysis. It is found that the demagnetizing factor may depend strongly upon the high-spin fraction of the film, and the specifics of the dependence are dictated by the microscopic morphology of the photomagnetic domains. This picture allows for facile interpretation of existing data on photomagnetic films, and can even explain an observed photoinduced decrease in low-field magnetization concurrent with increase in high-spin fraction. As a whole, these results reiterate the need to consider demagnetizing effects in photomagnetic films. - Highlights: Black-Right-Pointing-Pointer Finite element methods are used to examine demagnetization in photomagnetic films. Black-Right-Pointing-Pointer Under the right conditions, photomagnetic films may show a photoinduced decrease. Black-Right-Pointing-Pointer Demagnetization in photomagnets will be important to consider in possible devices.

  17. Comparative review of computed tomography of the spinal column and conventional x-ray films

    Energy Technology Data Exchange (ETDEWEB)

    Shin, H.; Yamaura, A.; Horie, T.; Makino, H. (Chiba Univ. (Japan). School of Medicine)

    1982-04-01

    Computerized tomography (CT) of the cervical spinal column was carried out in 39 patients using a GE.CT/T or Toshiba TCT60A scanner. There were 22 cervical disk lesions, 4 spinal neoplasms, 5 narrow spinal canals with or without ossification of the posterior longitudinal ligament, 2 syringomyelias, 5 traumas, and one Arnold-Chiari malformation. In all the patients, tomography was done after conventional spinal X-ray studies. The correlation between the CT findings and conventional X-ray films revealed the excellent capability of the CT. The measurement of the midline sagittal diameter of the spinal canal in the patient with the narrowest canal in this series showed 7.4 mm when done by CT and 9.6 mm when done by the conventional plain film at the C/sub 5/ level. To ascertain the precise sagittal diameter of the cord itself, CT myelography is indispensable after the intrathecal injection of metrizamide A; metrizamide CT myelogram is useful in determining the nature of the disease, the risk of and best approach to surgery, and the evaluation after a surgical procedure. Although the range of motion of cervical joints and intervertebral foramen are visible with the conventional films, the size of the spinal tumors, the degree of bony change, and the tumor extension to the paraspinal connective tissue can be precisely demonstrated only by CT. A CT study of the spine is a simple procedure and is less likely to produce complication, even with a metrizamide CT myelogram, though there are certain limitations in the examination.

  18. Student film clinches top prize in film competition

    OpenAIRE

    Elliott, Jean

    2006-01-01

    Virginia Tech senior Tim Leaton earned the top prize in the widely acclaimed Film Your Issue (FYI) competition - an eight-week paid internship at Disney Studios in Los Angeles. Leaton's one-minute film, "Orphans in Africa," won the nationwide contest, an initiative to encourage young Americans, age 18 to 26, to engage in social issues and add their voices to the public dialogue.

  19. Heritage film set : the protection and care of historic filming locations

    OpenAIRE

    Flynn, Clare

    2016-01-01

    Taking part in filming can offer considerable benefits to the historic properties involved, including increased visitor numbers, public awareness, and funding that can facilitate the ongoing care and conservation of the featured properties. However, film shoots are also intrusive events that introduce serious threats to the historic built fabric of these properties. This dissertation will investigate how the conservation integrity of heritage sites and properties is maintained when film shoot...

  20. Film Censorship Policy During Park Chung Hee’s Military Regime (1960–1979 and Hostess Films

    Directory of Open Access Journals (Sweden)

    Molly Hyo Kim

    2018-04-01

    Full Text Available Park Chung-hee’s military government (1960-1979 purportedly used film censorship to distract the public from political consciousness by controlling political materials in films while condoning censorship control on sexual content. As a result, the production of soft-core adult films soared and became popular among Korean audiences. One such film genre that thrived during this period, so-called hostess films (prostitute films, is worthy of attention for the films’ foregrounding issues of class, poverty and other social issues that the state censorship board heavily regulated. In viewing such dynamics between state censorship and film, this article aims to unravel the questions of how the state was willing to turn a blind eye to the explicit sexualization of women in hostess films when film censorship was at its peak and why the social and political aspects of this group of films about female sexual workers were not considered socially relevant by the censorship board, through scrutinizing the interplay between Park’s state censorship and hostess films. Furthermore, it offers an analysis of a hostess film, The Rose that Swallowed Thorn (Cheong, 1979, as a case study to show how it strategically orchestrates visual and thematic elements to circumvent censorship enforcement.

  1. Organic Photovoltaic Devices Based on Oriented n-Type Molecular Films Deposited on Oriented Polythiophene Films.

    Science.gov (United States)

    Mizokuro, Toshiko; Tanigaki, Nobutaka; Miyadera, Tetsuhiko; Shibata, Yousei; Koganezawa, Tomoyuki

    2018-04-01

    The molecular orientation of π-conjugated molecules has been reported to significantly affect the performance of organic photovoltaic devices (OPVs) based on molecular films. Hence, the control of molecular orientation is a key issue toward the improvement of OPV performance. In this research, oriented thin films of an n-type molecule, 3,4,9,10-Perylenetetracarboxylic Bisbenzimida-zole (PTCBI), were formed by deposition on in-plane oriented polythiophene (PT) films. Orientation of the PTCBI films was evaluated by polarized UV-vis spectroscopy and 2D-Grazing incidence X-ray diffraction. Results indicated that PTCBI molecules on PT film exhibit nearly edge-on and in-plane orientation (with molecular long axis along the substrate), whereas PTCBI molecules without PT film exhibit neither. OPVs composed of PTCBI molecular film with and without PT were fabricated and evaluated for correlation of orientation with performance. The OPVs composed of PTCBI film with PT showed higher power conversion efficiency (PCE) than that of film without PT. The experiment indicated that in-plane orientation of PTCBI molecules absorbs incident light more efficiently, leading to increase in PCE.

  2. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2006-01-01

    The object of this paper is to give a new user some practical information on the use of radiochromic films for medical applications. While various aspects of radiochromic film dosimetry for medical applications have been covered in some detail in several other excellent review articles which have appeared in the last few years [Niroomand-Rad, A., Blackwell, C.R., Coursey, B.M., Gall, K.P., McLaughlin, W.L., Meigooni, A.S., Nath, R., Rodgers, J.E., Soares, C.G., 1998. Radiochromic dosimetry: recommendations of the AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25, 2093-2115; Dempsey, J.F., Low, D.A., Mutic, S., Markman, J., Kirov, A.S., Nussbaum, G.H., Williamson, J.F., 2000. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions. Med. Phys. 27, 2462-2475; Butson, M.J., Yu, P.K.N., Cheung, T., Metcalfe, P., 2003. Radiochromic film for medical radiation dosimetry. Mater. Sci. Eng. R41, 61-120], it is the intent of the present author to present material from a more user-oriented and practical standpoint. That is, how the films work will be stressed much less than how to make the films work well. The strength of radiochromic films is most evident in applications where there is a very high dose gradient and relatively high absorbed dose rates. These conditions are associated with brachytherapy applications, measurement of small fields, and at the edges (penumbra regions) of larger fields

  3. US/Russian Joint Film Test

    Science.gov (United States)

    Slater, Richard

    1996-01-01

    A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia's Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and an evaluation of the test data by the RKK Energia. ISC's evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.

  4. Film Censorship Policy During Park Chung Hee’s Military Regime (1960–1979) and Hostess Films

    OpenAIRE

    Molly Hyo Kim

    2018-01-01

    Park Chung-hee’s military government (1960-1979) purportedly used film censorship to distract the public from political consciousness by controlling political materials in films while condoning censorship control on sexual content. As a result, the production of soft-core adult films soared and became popular among Korean audiences. One such film genre that thrived during this period, so-called hostess films (prostitute films), is worthy of attention for the films’ foregrounding issues of cla...

  5. Feature Extraction of Weld Defectology in Digital Image of Radiographic Film Using Geometric Invariant Moment and Statistical Texture

    International Nuclear Information System (INIS)

    Muhtadan

    2009-01-01

    The purpose of this research is to perform feature extraction in weld defect of digital image of radiographic film using geometric invariant moment and statistical texture method. Feature extraction values can be use as values that used to classify and pattern recognition on interpretation of weld defect in digital image of radiographic film by computer automatically. Weld defectology type that used in this research are longitudinal crack, transversal crack, distributed porosity, clustered porosity, wormhole, and no defect. Research methodology on this research are program development to read digital image, then performing image cropping to localize weld position, and then applying geometric invariant moment and statistical texture formulas to find feature values. The result of this research are feature extraction values that have tested with RST (rotation, scale, transformation) treatment and yield moment values that more invariant there are ϕ 3 , ϕ 4 , ϕ 5 from geometric invariant moment method. Feature values from statistical texture that are average intensity, average contrast, smoothness, 3 rd moment, uniformity, and entropy, they used as feature extraction values. (author)

  6. High-throughput characterization of film thickness in thin film materials libraries by digital holographic microscopy

    International Nuclear Information System (INIS)

    Lai Yiuwai; Hofmann, Martin R; Ludwig, Alfred; Krause, Michael; Savan, Alan; Thienhaus, Sigurd; Koukourakis, Nektarios

    2011-01-01

    A high-throughput characterization technique based on digital holography for mapping film thickness in thin-film materials libraries was developed. Digital holographic microscopy is used for fully automatic measurements of the thickness of patterned films with nanometer resolution. The method has several significant advantages over conventional stylus profilometry: it is contactless and fast, substrate bending is compensated, and the experimental setup is simple. Patterned films prepared by different combinatorial thin-film approaches were characterized to investigate and demonstrate this method. The results show that this technique is valuable for the quick, reliable and high-throughput determination of the film thickness distribution in combinatorial materials research. Importantly, it can also be applied to thin films that have been structured by shadow masking.

  7. High-throughput characterization of film thickness in thin film materials libraries by digital holographic microscopy.

    Science.gov (United States)

    Lai, Yiu Wai; Krause, Michael; Savan, Alan; Thienhaus, Sigurd; Koukourakis, Nektarios; Hofmann, Martin R; Ludwig, Alfred

    2011-10-01

    A high-throughput characterization technique based on digital holography for mapping film thickness in thin-film materials libraries was developed. Digital holographic microscopy is used for fully automatic measurements of the thickness of patterned films with nanometer resolution. The method has several significant advantages over conventional stylus profilometry: it is contactless and fast, substrate bending is compensated, and the experimental setup is simple. Patterned films prepared by different combinatorial thin-film approaches were characterized to investigate and demonstrate this method. The results show that this technique is valuable for the quick, reliable and high-throughput determination of the film thickness distribution in combinatorial materials research. Importantly, it can also be applied to thin films that have been structured by shadow masking.

  8. Thin Cu film resistivity using four probe techniques: Effect of film thickness and geometrical shapes

    Science.gov (United States)

    Choudhary, Sumita; Narula, Rahul; Gangopadhyay, Subhashis

    2018-05-01

    Precise measurement of electrical sheet resistance and resistivity of metallic thin Cu films may play a significant role in temperature sensing by means of resistivity changes which can further act as a safety measure of various electronic devices during their operation. Four point probes resistivity measurement is a useful approach as it successfully excludes the contact resistance between the probes and film surface of the sample. Although, the resistivity of bulk samples at a particular temperature mostly depends on its materialistic property, however, it may significantly differ in the case of thin films, where the shape and thickness of the sample can significantly influence on it. Depending on the ratio of the film thickness to probe spacing, samples are usually classified in two segments such as (i) thick films or (ii) thin films. Accordingly, the geometric correction factors G can be related to the sample resistivity r, which has been calculated here for thin Cu films of thickness up to few 100 nm. In this study, various rectangular shapes of thin Cu films have been used to determine the shape induced geometric correction factors G. An expressions for G have been obtained as a function of film thickness t versus the probe spacing s. Using these expressions, the correction factors have been plotted separately for each cases as a function of (a) film thickness for fixed linear probe spacing and (b) probe distance from the edge of the film surface for particular thickness. Finally, we compare the experimental results of thin Cu films of various rectangular geometries with the theoretical reported results.

  9. Film, Neuroaesthetics, and Empathy

    DEFF Research Database (Denmark)

    Grodal, Torben Kragh; Kramer, Mette

    2014-01-01

    The article analyzes the link between film viewing and human 'ultra-sociality' (Boyd and Richardson 1998), describing how empathy is supported by mirror resonances but also modified by appraisal mechanisms and how emotions are communicated, It further discusses how 'attainment' to film builds...... on mother-child communication and also how film genres of attachment use such attainment, especially by means of close-ups of human faces and shot-reverse shots. Finally it deals with how films boost development of cognitive and emotional intelligence...

  10. Atomic-Layer-Deposition of Indium Oxide Nano-films for Thin-Film Transistors.

    Science.gov (United States)

    Ma, Qian; Zheng, He-Mei; Shao, Yan; Zhu, Bao; Liu, Wen-Jun; Ding, Shi-Jin; Zhang, David Wei

    2018-01-09

    Atomic-layer-deposition (ALD) of In 2 O 3 nano-films has been investigated using cyclopentadienyl indium (InCp) and hydrogen peroxide (H 2 O 2 ) as precursors. The In 2 O 3 films can be deposited preferentially at relatively low temperatures of 160-200 °C, exhibiting a stable growth rate of 1.4-1.5 Å/cycle. The surface roughness of the deposited film increases gradually with deposition temperature, which is attributed to the enhanced crystallization of the film at a higher deposition temperature. As the deposition temperature increases from 150 to 200 °C, the optical band gap (E g ) of the deposited film rises from 3.42 to 3.75 eV. In addition, with the increase of deposition temperature, the atomic ratio of In to O in the as-deposited film gradually shifts towards that in the stoichiometric In 2 O 3 , and the carbon content also reduces by degrees. For 200 °C deposition temperature, the deposited film exhibits an In:O ratio of 1:1.36 and no carbon incorporation. Further, high-performance In 2 O 3 thin-film transistors with an Al 2 O 3 gate dielectric were achieved by post-annealing in air at 300 °C for appropriate time, demonstrating a field-effect mobility of 7.8 cm 2 /V⋅s, a subthreshold swing of 0.32 V/dec, and an on/off current ratio of 10 7 . This was ascribed to passivation of oxygen vacancies in the device channel.

  11. Dynamics of a longitudinal current during a magnetic storm

    International Nuclear Information System (INIS)

    Dolginov, S.Sh.; Zhuzgov, L.N.; Kosacheva, V.P.; Strunnikova, L.N.; Tyurmina, L.O.; Sharova, V.A.; Shkol'nikova, S.I.

    1984-01-01

    Results, investigating a spatial distribution and the structure of longitudinal currents during a magnetic storm at 18-19.09.81, are presented. It is shown that during the main phase of the storm the large-scale current system expands to the equator, and current density increases. Inside the current layer and to the pole of it there appears intensive small scale longitudinal l currents. During magnetic storm restopation phase the current system segregates into several pairs of opposite directed currents. During further decreasing of geomagnetic activity the large-scale current system is restored+ and its center is shifted to the pole, longitudinal current density being decreased. The invariant width of longitudinal currents is decreased, while the magnitude, Dsub(st), being increased, that is connected to the displacement of an auroral oval to the equator

  12. Multi-longitudinal-mode micro-laser model

    Science.gov (United States)

    Staliunas, Kestutis

    2017-10-01

    We derive a convenient model for broad aperture micro-lasers, such as microchip lasers, broad area semiconductor lasers, or VCSELs, taking into account several longitudinal mode families. We provide linear stability analysis, and show characteristic spatio-temporal dynamics in such multi-longitudinal mode laser models. Moreover, we derive the coupled mode model in the presence of intracavity refraction index modulation (intracavity photonic crystal). Contribution to the Topical Issue "Theory and Applications of the Lugiato-Lefever Equation", edited by Yanne K. Chembo, Damia Gomila, Mustapha Tlidi, Curtis R. Menyuk.

  13. Underwater 3D filming

    Directory of Open Access Journals (Sweden)

    Roberto Rinaldi

    2014-12-01

    Full Text Available After an experimental phase of many years, 3D filming is now effective and successful. Improvements are still possible, but the film industry achieved memorable success on 3D movie’s box offices due to the overall quality of its products. Special environments such as space (“Gravity” and the underwater realm look perfect to be reproduced in 3D. “Filming in space” was possible in “Gravity” using special effects and computer graphic. The underwater realm is still difficult to be handled. Underwater filming in 3D was not that easy and effective as filming in 2D, since not long ago. After almost 3 years of research, a French, Austrian and Italian team realized a perfect tool to film underwater, in 3D, without any constrains. This allows filmmakers to bring the audience deep inside an environment where they most probably will never have the chance to be.

  14. a short "istory of the development of south africa's naval uniform

    African Journals Online (AJOL)

    crown and two stars. All the badges on our Flag Officers' shoulder straps were initially silver. The castles and lions are now silver wire badges. Further South African innovations include the letters V worn by citizen. Force officers and C worn by Cadet Officers'. Training Corps (School Cadets) officers within the curl of their ...

  15. Longitudinal Risk Factors for Cyberbullying in Adolescence

    OpenAIRE

    Sticca, Fabio; Ruggieri, Sabrina; Alsaker, Françoise; Perren, Sonja

    2013-01-01

    Cyberbullying has emerged as a new form of antisocial behaviour in the context of online communication over the last decade. The present study investigates potential longitudinal risk factors for cyberbullying. A total of 835 Swiss seventh graders participated in a short-term longitudinal study (two assessments 6 months apart). Students reported on the frequency of cyberbullying, traditional bullying, rule-breaking behaviour, cybervictimisation, traditional victimisation, and frequency of onl...

  16. Film-thickness dependence of structure formation in ultra-thin polymer blend films

    CERN Document Server

    Gutmann, J S; Stamm, M

    2002-01-01

    We investigated the film-thickness dependence of structure formation in ultra-thin polymer blend films prepared from solution. As a model system we used binary blends of statistical poly(styrene-co-p-bromostyrene) copolymers of different degrees of bromination. Ultra-thin-film samples differing in miscibility and film thickness were prepared via spin coating of common toluene solutions onto silicon (100) substrates. The resulting morphologies were investigated with scanning force microscopy, reflectometry and grazing-incidence scattering techniques using both X-rays and neutrons in order to obtain a picture of the sample structure at and below the sample surface. (orig.)

  17. Effect of micro-patterned fluorine-doped tin oxide films on electrochromic properties of Prussian blue films

    International Nuclear Information System (INIS)

    Lee, Kyuha; Kim, A-Young; Park, Ji Hun; Jung, Hun-Gi; Choi, Wonchang; Lee, Hwa Young; Lee, Joong Kee

    2014-01-01

    Graphical abstract: - Highlights: • PB-based ECD employed micro-patterned FTO electrode was fabricated. • Effect of interface morphology on electrochromic characteristics was examined. • Electrochromic properties were enhanced by employing a patterned interface. - Abstract: The effect of interface morphology on electrochromic characteristics was examined for an electrochromic device (ECD). Micro-patterned fluorine-doped tin oxide (FTO) films were fabricated using a photolithography process. Prussian blue (PB) films were then deposited on the patterned FTO films. The surface areas of both PB films and FTO films were increased by patterning. ECDs were assembled using patterned PB/FTO films as the electrochromic electrode, bare FTO films as the counter electrode, and an electrolyte containing LiClO 4 salt. The increased effective surface area of the patterned PB/FTO electrode boosted the mobility of ions at the interphase between the electrolyte and PB electrode, and the electron transfer between PB films and FTO films. As a result, electrochromic properties such as transmittance and response time were significantly improved by employing the patterned FTO films as the transparent conductive oxide layer of the electrochromic electrode

  18. [Spectroscopic study on film formation mechanism and structure of composite silanes-V-Zr passive film].

    Science.gov (United States)

    Wang, Lei; Liu, Chang-sheng; Shi, Lei; An, Cheng-qiang

    2015-02-01

    A composite silanes-V-Zr passive film was overlayed on hot-dip galvanized steel. Attenuated total reflection Fourier transformed infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectrometer (XPS) and radio frequency glow discharge optical emission spectrometry (rf-GD-OES) were used to characterize the molecular structure of the silanes-V-Zr passive film. The mechanism of film formation was discussed: The results show that the silane molecules are crosslinked as the main film former and inorganic inhibitor is even distributed in the film. The fitting peak of 100.7 eV in XPS single Si2p energy range spectra of the composite silanes-V-Zr passive film and the widening and strengthening of the Si--O infrared absorption peak at 1100 cm(-1) indicate that the silanes were adsorbed on the surface of zinc with chemical bond of Si--O--Zn, and the silane molecules were connected with each other by bond of Si--O--Si. Two characteristic absorption peaks of amide at 1650 and 1560 cm(-1) appear in the infrared spectroscopy of the composite silanes-V-Zr passive film, and a characteristic absorption peak of epoxy groups at 910 cm(-1) disappears in the infrared spectroscopy of the passive film. The results indicate that gamma-APT can be prepared through nucleophilic ring-opening of ethylene oxide in gamma-GPT molecule to form C--N covalent bonds. The rf-GD-OES results indicate that there is a oxygen enriched layer in 0.3 microm depth of the composite silanes-V-Zr passive film. Moreover, ZrF4, ZrO2 and some inorganic matter obtained by the reaction during the forming processof the composite silanes-V-Zr passive film are distributed evenly throughout the film. According to the film composition, the physical processes and chemical reactions during the film forming process were studied by using ATR-FTIR. Based on this, the film forming mechanism was proposed.

  19. Fire resistant films for aircraft applications

    Science.gov (United States)

    Kourtides, D. A.

    1983-01-01

    Alternative sandwich panel decorative films were investigated as replacements for the polyvinyl fluoride currently used in aircraft interiors. Candidate films were studied for flammability, smoke emission, toxic gas emission, flame spread, and suitability as a printing surface for the decorative acrylic ink system. Several of the candidate films tested were flame modified polyvinyl fluoride, polyvinylidene fluoride, polyimide, polyamide, polysulfone, polyphenylsulfone, polyethersulfone, polybenzimidazole, polycarbonate, polyparabanic acid, polyphosphazene, polyetheretherketon, and polyester. The films were evaluated as pure films only, films silk-screened with an acrylic ink, and films adhered to a phenolic fiberglass substrate. Films which exhibited the highest fire resistant properties included PEEK polyetheretherketon, Aramid polyamide, and ISO-BPE polyester.

  20. Predicting film genres with implicit ideals

    Directory of Open Access Journals (Sweden)

    Andrew McGregor Olney

    2013-01-01

    Full Text Available We present a new approach to defining film genre based on implicit ideals. When viewers rate the likability of a film, they indirectly express their ideal of what a film should be. Across six studies we investigate the category structure that emerges from likability ratings and the category structure that emerges from the features of film. We further compare these data-driven category structures with human annotated film genres. We conclude that film genres are structured more around ideals than around features of film. This finding lends experimental support to the notion that film genres are set of shifting, fuzzy, and highly contextualized psychological categories.