  1. Long-term pumping test in borehole KR24 flow measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rouhiainen, P.; Poellaenen, J. [PRG-Tec Oy, Espoo (Finland)

    2005-09-15

    The Difference Flow method can be used for the relatively fast determination of transmissivity and hydraulic head in fractures or fractured zones in cored boreholes. In this study, the Difference Flow method was used for hydraulic crosshole interference tests. The tests were performed in boreholes KR24 (pumped borehole) KR4, KR7, KR8, KRlO, KR14, KR22, KR22B, KR26, KR27, KR27B, KR28 and KR28B at Olkiluoto during the first and second quarters of 2004. The distance between the boreholes varies from approximately tens of meters to hundreds of meters. All the measurements were carried out in open boreholes, i.e. no packers were used. For interpretation, a normal single hole test was first performed in each borehole. Flow rates and drawdown were first measured both without pumping and with pumping the borehole under test. For practical reasons, the data set is neither complete nor similar in all tested boreholes. Connected flow to borehole KR24 was detected in all these boreholes. These flow responses were concentrated on a few zones. (orig.)

  2. CRIEPI and SKB cooperation report. No.11. Numerical analysis for long-term pumping test at crystalline terrain

    International Nuclear Information System (INIS)

    Tanaka, Yasuharu

    2012-01-01

    A numerical analysis code for groundwater flow in rock mass, FEGM, which was developed by CRIEPI, was applied to the analysis of a long-term pumping test conducted at Olkiluoto Island in Finland. The groundwater level, the groundwater pressure and the groundwater inflow into the observation boreholes measured under the natural condition or during the pumping test could be reproduced in numerical simulations with FEGM. From this, the effectiveness of the numerical code was confirmed. And it was found that the site-scale groundwater flow is dependent on large-scale fracture zones in crystalline terrane like Olkiluoto Island. In this study, the calculated values of the groundwater inflow into the observation boreholes as well as the groundwater level and the groundwater pressure were compared to the measured ones. As a result, the reliability of the analytical model was improved. In addition, the travel times of groundwater particles from different depths at the same point to the model boundaries were compared. And the advantage of constructing waste disposal facilities at deep underground was confirmed from the viewpoint of the travel time of groundwater. (author)

  3. Changes in Chemical and Isotopic Composition of Groundwater during Long-Term Pumping Test in Brestovica Karst Aquifer

    International Nuclear Information System (INIS)

    Mezga, Kim; Urbanc, Janko

    2011-01-01

    The main aim of the experimental pumping test, which was carried out in the dry summer period in August 2008 for 30 days, was to assess the groundwater resource quantity which could be pumped at the time of the highest water needs for the Slovene Coast and Karst areas. Further, we wanted to test the chemical status of groundwater to assure its suitability for further use and to assess the influence of the Soca River aquifer on this karst aquifer

  4. Changes in Chemical and Isotopic Composition of Groundwater During a Long Term Pumping Test in Brestovica Karst Aquifer

    Energy Technology Data Exchange (ETDEWEB)

    Mezga, K.; Urbanc, J. [Geological Survey of Slovenia, Department of Hydrogeology, Ljubljana (Slovenia)

    2013-07-15

    A pumping test of the Klarici water supply near Brestovica was performed in August 2008, in order to determine the karst groundwater resource capacity. Groundwater was pumped for a month with a total capacity of 470 L/s. During the experiment, sampling for chemical and isotopic composition of groundwater and surface water was carried out. Intensive pumping in dry meteorological conditions caused a lowering of the water table and changes in the chemical and isotopic composition of pumped water. Local meteoric waters are infiltrated into the aquifer at a lower mean altitude; therefore the {delta}{sup 18}O is enriched with the heavy oxygen isotope. The duration of pumping resulted in changes in the isotopic composition of oxygen due to a greater impact of the intergranular Soca River aquifer on the karst aquifer. On the basis of isotope composition it was possible to quantify the impact of the Soca River on the karst aquifer. (author)

  5. Decision document for performing a long-term pumping test at the S-3 Site, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1995-02-01

    One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its technical practicability, effectiveness, and projected cost must be determined. A long-term pumping test (LTPT) at the S-3 Site has been proposed so that the information necessary to carry out this evaluation can be collected. This document constitutes the first phase in the planning process for this test

  6. Groundwater sampling at Olkiluoto, Eurajoki from the borehole OL-KR6 during a long-term pumping test in 2006

    International Nuclear Information System (INIS)

    Hirvonen, H.; Hatanpaeae, E.; Ahokas, H.

    2007-05-01

    A long-term pumping test at borehole OL-KR6 at Olkiluoto was initiated in 2001. Since then, flow and in situ EC measurements as well as groundwater sampling from specific sampling sections have been performed yearly. The aim of this study was to obtain information on the potential connections via fractures both to the sea and to deep saline groundwater during long-term pumping of the open borehole. In 2006, four groundwater samples were collected from four different sampling depths (98.5-100.5 m, 125-130 m, 135-137 m and 422-425 m). The groundwater samples were taken in stages using PAVE equipment. The water types found in the groundwater samples from OL-KR6 were Na-Ca-Cl (for samples from depths of 98.5-100.5 m and 125-130 m) and Na-Cl (for samples from depths of 135-137 m and 422-425 m). The sample from depth 422-425 m was saline (TDS> 10000 mg/l), while other waters were brackish (1000 mg < TDS <10000 mg/l). This study presents the sampling methods and analysis results of groundwater samples from deep borehole OL-KR6, and draws a comparison between the results of the in situ EC measurements and the EC results measured during groundwater sampling. This report also contains a short comparison of the results obtained from the long-term pumping test conducted between 2001-2006. In situ EC results and EC results measured in laboratory are in quite good agreement. At sampling depth, 422-425 m, EC increased between 2004-2006. At a depth of 423 m, much variation in situ EC-values indicates that routes of groundwater may change during long-term pumping due to the limited storages of different aquifers or the heterogeneity of the content of groundwater in different locations in the bedrock. The minor systematic difference between in situ and sampling EC at a depth of 136 m was probably due to the different flow fields during flow logging and water sampling. The dominant gas in the groundwater samples was nitrogen. Carbon dioxide was the second dominant gas, except for the

  7. Long-term safety issues associated with mixer pump operation

    International Nuclear Information System (INIS)

    Kubic, W.L. Jr.

    1994-01-01

    In this report, we examine several long-term issues: the effect of pump operation on future gas release events (GREs), uncontrolled chemical reactions, chronic toxic gas releases, foaming, and erosion and corrosion. Heat load in excess of the design limit, uncontrolled chemical reactions, chronic toxic gas releases, foaming, and erosion and corrosion have been shown not to be safety concerns. The effect of pump operation on future GREs could not be quantified. The problem with evaluating the long-term effects of pump operation on GREs is a lack of knowledge and uncertainty. In particular, the phenomena governing gas retention, particle size distribution, and settling are not well understood, nor are the interactions among these factors understood. There is a possibility that changes in these factors could increase the size of future GREs. Bounding estimates of the potential increase in size of GREs are not possible because of a lack of engineering data. Proper management of the hazards can reduce, but not eliminate, the possibility of undesirable changes. Maintaining temperature within the historical limits can reduce the possibility of undesirable changes. A monitoring program to detect changes in the gas composition and crust thickness will help detect slowly occurring changes. Because pump operation has be shown to eliminate GREs, continued pump operation can eliminate the hazards associated with future GREs

  8. Long term testing of PSI-membranes

    Energy Technology Data Exchange (ETDEWEB)

    Huslage, J; Brack, H P; Geiger, F; Buechi, F N; Tsukada, A; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Long term tests of PSI membranes based on radiation-grafted FEP and ETFE films were carried out and FEP-based membranes were evaluated by monitoring the in-situ membrane area resistance measured by a current pulse method. By modifying our irradiation procedure and using the double crosslinking concept we obtain reproducible membrane cell lifetimes (in term of in-situ membrane resistance) of greater than 5000 hours at 60-65{sup o}C. Preliminary tests at 80-85{sup o}C with lifetimes of greater than 2500 demonstrate the potential long term stability of PSI proton exchange membranes based on FEP over the whole operating temperature range of low-temperature polymer electrolyte fuel cells. Radiation grafted PSI membranes based on ETFE have better mechanical properties than those of the FEP membranes. Mechanical properties are particularly important in large area cells and fuel cell stacks. ETFE membranes have been tested successfully for approximately 1000 h in a 2-cell stack (100 cm{sup 2} active area each cell). (author) 4 figs., 4 refs.

  9. Hot functional test chemistry - long term experience

    International Nuclear Information System (INIS)

    Vonkova, K.; Kysela, J.; Marcinsky, M.; Martykan, M.

    2010-01-01

    Primary circuit materials undergo general corrosion in high temperature, deoxygenated, neutral or mildly alkaline solutions to form thin oxide films. These oxide layers (films) serve as protective film and mitigate the further corrosion of primary materials. Inner chromium-rich oxide layer has low cation diffusion coefficients and thus control iron and nickel transport from the metal surface to the outer layer and their dissolution into the coolant. Much less corrosion products are generated by the compact, integral and stable oxide (passivation) layer. For the latest Czech and Slovak stations commissioned (Temelin and Mochovce) a modified Hot Functional Test (HFT) chemistry was developed in the NRI Rez. Chromium rich surface layer formatted due to modified HTF chemistry ensures lower corrosion rates and radiation field formation and thus also mitigates crud formation during operation. This procedure was also designed to prepare the commissioned unit for the further proper water chemistry practise. Mochovce 1 (SK) was the first station commissioned using these recommendations in 1998. Mochovce 2 (1999) and Temelin 1 and 2 (CZ - 2000 and 2002) were subsequently commissioned using these guidelines too. The main principles of the controlled primary water chemistry applied during the hot functional tests are reviewed and importance of the water chemistry, technological and other relevant parameters is stressed regarding to the quality of the passive layer formed on the primary system surfaces. Samples from Mochovce indicated that duplex oxide layers up to 20 μm thick were produced, which were mainly magnetite substituted with nickel and chromium (e.g. 60-65% Fe, 18-28% Cr, 9-12% Ni, <1% Mn and 1-2% Si on a stainless steel primary circuit sample). Long term operation experience from both nuclear power plants are discussed in this paper. Radiation field, occupational radiation exposure and corrosion layers evolution during the first c. ten years of operation are

  10. Long-term pumping test to study the impact of an open-loop geothermal system on seawater intrusion in a coastal aquifer: the case study of Bari (Southern Italy)

    Science.gov (United States)

    Clementina Caputo, Maria; Masciale, Rita; Masciopinto, Costantino; De Carlo, Lorenzo

    2016-04-01

    The high cost and scarcity of fossil fuels have promoted the increased use of natural heat for a number of direct applications. Just as for fossil fuels, the exploitation of geothermal energy should consider its environmental impact and sustainability. Particular attention deserves the so-called open loop geothermal groundwater heat pump (GWHP) system, which uses groundwater as geothermal fluid. From an economic point of view, the implementation of this kind of geothermal system is particularly attractive in coastal areas, which have generally shallow aquifers. Anyway the potential problem of seawater intrusion has led to laws that restrict the use of groundwater. The scarcity of freshwater could be a major impediment for the utilization of geothermal resources. In this study a new methodology has been proposed. It was based on an experimental approach to characterize a coastal area in order to exploit the low-enthalpy geothermal resource. The coastal karst and fractured aquifer near Bari, in Southern Italy, was selected for this purpose. For the purpose of investigating the influence of an open-loop GWHP system on the seawater intrusion, a long-term pumping test was performed. The test simulated the effects of a prolonged withdrawal on the chemical-physical groundwater characteristics of the studied aquifer portion. The duration of the test was programmed in 16 days, and it was performed with a constant pumping flowrate of 50 m3/h. The extracted water was outflowed into an adjacent artificial channel, by means of a piping system. Water depth, temperature and electrical conductivity of the pumped water were monitored for 37 days, including also some days before and after the pumping duration. The monitored parameters, collected in the pumping and in five observation wells placed 160 m down-gradient with respect to the groundwater flow direction, have been used to estimate different scenarios of the impact of the GWHP system on the seawater intrusion by mean of a

  11. Identification of pumping influences in long-term water level fluctuations.

    Science.gov (United States)

    Harp, Dylan R; Vesselinov, Velimir V

    2011-01-01

    Identification of the pumping influences at monitoring wells caused by spatially and temporally variable water supply pumping can be a challenging, yet an important hydrogeological task. The information that can be obtained can be critical for conceptualization of the hydrogeological conditions and indications of the zone of influence of the individual pumping wells. However, the pumping influences are often intermittent and small in magnitude with variable production rates from multiple pumping wells. While these difficulties may support an inclination to abandon the existing dataset and conduct a dedicated cross-hole pumping test, that option can be challenging and expensive to coordinate and execute. This paper presents a method that utilizes a simple analytical modeling approach for analysis of a long-term water level record utilizing an inverse modeling approach. The methodology allows the identification of pumping wells influencing the water level fluctuations. Thus, the analysis provides an efficient and cost-effective alternative to designed and coordinated cross-hole pumping tests. We apply this method on a dataset from the Los Alamos National Laboratory site. Our analysis also provides (1) an evaluation of the information content of the transient water level data; (2) indications of potential structures of the aquifer heterogeneity inhibiting or promoting pressure propagation; and (3) guidance for the development of more complicated models requiring detailed specification of the aquifer heterogeneity. Copyright © 2010 The Author(s). Journal compilation © 2010 National Ground Water Association.

  12. An implantable centrifugal blood pump for long term circulatory support.

    Science.gov (United States)

    Yamazaki, K; Litwak, P; Kormos, R L; Mori, T; Tagusari, O; Antaki, J F; Kameneva, M; Watach, M; Gordon, L; Umezu, M; Tomioka, J; Koyanagi, H; Griffith, B P

    1997-01-01

    A compact centrifugal blood pump was developed as an implantable left ventricular assist system. The impeller diameter is 40 mm and the pump dimensions are 55 x 64 mm. This first prototype was fabricated from titanium alloy, resulting in a pump weight of 400 g including a brushless DC motor. Weight of the second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon to improve blood compatibility. Flow rates of over 7 L/min against 100 mmHg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system ("Cool-Seal") is used as a shaft seal. In this seal system, seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. The purge fluid is continuously purified and sterilized by an ultrafiltration filter incorporated into the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular apex-descending aorta bypass was performed utilizing a PTFE (Polytetrafluoroethylene) vascular graft, with the pump placed in the left thoracic cavity. In two in vivo experiments, pump flow rate was maintained at 5-8 L/min, and pump power consumption remained stable at 9-10 W. All plasma free hemoglobin levels were measured at < 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (< 0.5 ml/ day). Both animals remain under observation after 162 and 91 days of continuous pump function.

  13. Implications of the "observer effect" on modelling a long-term pumping test with hydraulically conductive boreholes in a discrete fracture network system.

    Science.gov (United States)

    Holton, D.; Frampton, A.; Cvetkovic, V.

    2006-12-01

    The Onkalo underground research facility for rock characterisation for nuclear waste disposal is located at Olkiluoto island, just off the Finnish coast in the Baltic Sea. Prior to the start of the excavation of the Onkalo facility, an extensive amount of hydraulic data has been collected during various pumping experiments from a large number of boreholes placed throughout an area of approximately 10 km2, reaching depths of 1000 meters below sea level. In particular, the hydraulic borehole data includes classical measurements of pressure, but also new measurements of flow rate and flow direction in boreholes (so called flow-logging). These measurements indicate large variations in heterogeneity and are a clear reflection of the discrete nature of the system. Here we present results from an ongoing project which aims to explore and asses the implications of these new flow-logging measurements to site descriptive modelling and modelling at performance assessment scales. The main challange of the first phase of this project is to obtain a greater understanding of a strongly heterogenious and anisotropic groundwater system in which open boreholes are located; that is, a system in which the observation boreholes themselves create new hydraulic conductive features of the groundwater system. The results presented are from recent hydraulic flow modelling simulations with a combined continuous porous media and discrete fracture network approach using a commercial finite-element software. An advantage of this approach is we may adapt a continuum mesh on the regional scale, were only a few conductive features are known, together with a local scale discrete fracture network approach, where detailed site-investigation has revealed a large amount of conductive features. Current findings indicate the system is sensitive to certain combinations of hydraulic features, and we quantify the significance of including these variations in terms of their implications for reduction of

  14. Automatic estimation of aquifer parameters using long-term water supply pumping and injection records

    Science.gov (United States)

    Luo, Ning; Illman, Walter A.

    2016-09-01

    Analyses are presented of long-term hydrographs perturbed by variable pumping/injection events in a confined aquifer at a municipal water-supply well field in the Region of Waterloo, Ontario (Canada). Such records are typically not considered for aquifer test analysis. Here, the water-level variations are fingerprinted to pumping/injection rate changes using the Theis model implemented in the WELLS code coupled with PEST. Analyses of these records yield a set of transmissivity ( T) and storativity ( S) estimates between each monitoring and production borehole. These individual estimates are found to poorly predict water-level variations at nearby monitoring boreholes not used in the calibration effort. On the other hand, the geometric means of the individual T and S estimates are similar to those obtained from previous pumping tests conducted at the same site and adequately predict water-level variations in other boreholes. The analyses reveal that long-term municipal water-level records are amenable to analyses using a simple analytical solution to estimate aquifer parameters. However, uniform parameters estimated with analytical solutions should be considered as first rough estimates. More accurate hydraulic parameters should be obtained by calibrating a three-dimensional numerical model that rigorously captures the complexities of the site with these data.

  15. Mixer pump long term operations plan for Tank 241-SY-101 mitigation

    International Nuclear Information System (INIS)

    Irwin, J.J.

    1994-01-01

    This document provides the general Operations Plan for performance of the mixer pump long term operations for Tank 241-SY-101 mitigation of gas retention and periodic release in Tank 101-SY. This operations plan will utilize a 112 kW (150 hp) mixing pump to agitate/suspend the particulates in the tank

  16. FEATURES OF LONG-TERM MECHANICAL CIRCULATORY SUPPORT WITH CONTINUOUS-FLOW PUMP

    Directory of Open Access Journals (Sweden)

    G. P. Itkin

    2012-01-01

    Full Text Available In a review of the comparative analysis of methods and tools for long-term mechanical circulatory support with continuous flow and pulsatile flow implantable pumps. Particular attention is paid to the choice of the optimal modes of the operation of pumps based on the physical principles of the interaction between a the steady flow of blood to the pulsatile mechanics of the heart chambers. 

  17. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

    Science.gov (United States)

    Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi

    2002-11-01

    We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.

  18. Effect of long-term proton pump inhibitor administration on gastric mucosal atrophy: A meta-analysis

    Science.gov (United States)

    Li, Zhong; Wu, Cong; Li, Ling; Wang, Zhaoming; Xie, Haibin; He, Xiaozhou; Feng, Jin

    2017-01-01

    Background/Aims: Proton pump inhibitors (PPIs) are widely used for the treatment of acid-related gastrointestinal diseases. Recently, some studies have reported that PPIs can alter the gastric mucosal architecture; however, the relationship remains controversial. This meta-analysis study was designed to quantify the association between long-term PPI administration and gastric atrophy. Materials and Methods: A PubMed search was conducted to identify studies using the keywords proton pump inhibitors or PPI and gastric atrophy or atrophic gastritis; the timeframe of publication searched was up to May 2016. Heterogeneity among studies was tested with the Q test; odds ratios (OR) and 95% confidence intervals (CI) were calculated. P values were calculated by I2 tests and regarded as statistically significant when <0.05. Results: We identified 13 studies that included 1465 patients under long-term PPI therapy and 1603 controls, with a total gastric atrophy rate of 14.50%. There was a higher presence of gastric atrophy (15.84%; statistically significant) in PPI group compared to the control group (13.29%) (OR: 1.55, 95% CI: 1.00–2.41). Conclusions: The pooled data suggest that long-term PPI use is associated with increased rates of gastric atrophy. Large-scale multicenter studies should be conducted to further investigate the relationship between acid suppressants and precancerous diseases. PMID:28721975

  19. A long-term analysis of pumped hydro storage to firm wind power

    International Nuclear Information System (INIS)

    Foley, A.M.; Leahy, P.G.; Li, K.; McKeogh, E.J.; Morrison, A.P.

    2015-01-01

    Highlights: • This is a long term generation analysis of a high wind power system. • A high CO 2 and fossil fuel price is closest to Ireland’s EU ETS 2020 target. • New pumped storage to firm wind is limited unless strong market costs exist. • Reserve for wind power show that ancillary services are relevant for balancing. - Abstract: Although pumped hydro storage is seen as a strategic key asset by grid operators, financing it is complicated in new liberalised markets. It could be argued that the optimum generation portfolio is now determined by the economic viability of generators based on a short to medium term return on investment. This has meant that capital intensive projects such as pumped hydro storage are less attractive for wholesale electricity companies because the payback periods are too long. In tandem a significant amount of wind power has entered the generation mix, which has resulted in operating and planning integration issues due to wind’s inherent uncertain, varying spatial and temporal nature. These integration issues can be overcome using fast acting gas peaking plant or energy storage. Most analysis of wind power integration using storage to date has used stochastic optimisation for power system balancing or arbitrage modelling to examine techno-economic viability. In this research a deterministic dynamic programming long term generation expansion model is employed to optimise the generation mix, total system costs and total carbon dioxide emissions, and unlike other studies calculates reserve to firm wind power. The key finding of this study is that the incentive to build capital-intensive pumped hydro storage to firm wind power is limited unless exogenous market costs come very strongly into play. Furthermore it was demonstrated that reserve increases with increasing wind power showing the importance of ancillary services in future power systems

  20. Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Loomis, H.

    2015-06-01

    Transformations, Inc. has extensive experience building their high performance housing at a variety of Massachusetts locations, in both a production and custom home setting. The majority of their construction uses mini-split heat pumps (MSHPs) for space conditioning. This research covered the long-term performance of MSHPs in Zone 5A; it is the culmination of up to 3 years' worth of monitoring in a set of eight houses. This research examined electricity use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions. The use of simplified space conditioning distribution (through use of MSHPs) provides significant first cost savings, which are used to offset the increased investment in the building enclosure.

  1. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  2. Long-term creep test with finite elements

    International Nuclear Information System (INIS)

    Argyris, J.H.; Szimmat, J.; Willam, K.J.

    1975-01-01

    Following a presentation of concrete creep, a brief summary of the direct and incremental calculation methods for long-term creep behaviour is given. In addition, a survey on the methods of the inner state variables is given which, on the one hand, gives a uniform framework for the various formulations of concrete creep, and on the other hand leads to a computable calculation method. Two examples on long-term creep behaviour illustrate the application field of the calculation method. (orig./LH) [de

  3. Long-term animal experiments with an intraventricular axial flow blood pump.

    Science.gov (United States)

    Yamazaki, K; Kormos, R L; Litwak, P; Tagusari, O; Mori, T; Antaki, J F; Kameneva, M; Watach, M; Gordon, L; Mukuo, H; Umezu, M; Tomioka, J; Outa, E; Griffith, B P; Koyanagai, H

    1997-01-01

    A miniature intraventricular axial flow blood pump (IVAP) is undergoing in vivo evaluation in calves. The IVAP system consists of a miniature (phi 13.9 mm) axial flow pump that resides within the left ventricular (LV) chamber and a brushless DC motor. The pump is fabricated from titanium alloy, and the pump weight is 170 g. It produces a flow rate of over 5 L/min against 100 mmHg pressure at 9,000 rpm with an 8 W total power consumption. The maximum total efficiency exceeds 17%. A purged lip seal system is used in prototype no. 8, and a newly developed "Cool-Seal" (a low temperature mechanical seal) is used in prototype no. 9. In the Cool-Seal system, a large amount of purge flow is introduced behind the seal faces to augment convective heat transfer, keeping the seal face temperature at a low level for prevention of heat denaturation of blood proteins. The Cool-Seal system consumes < 10 cc purge fluid per day and has greatly extended seal life. The pumps were implanted in three calves (26, 30, and 168 days of support). The pump was inserted through a left thoracotomy at the fifth intercostal space. Two pursestring sutures were placed on the LV apex, and the apex was cored with a myocardial punch. The pump was inserted into the LV with the outlet cannula smoothly passing through the aortic valve without any difficulty. Only 5 min elapsed between the time of chest opening and initiation of pumping. Pump function remained stable throughout in all experiments. No cardiac arrhythmias were detected, even at treadmill exercise tests. The plasma free hemoglobin level remained in the acceptable range. Post mortem examination did not reveal any interference between the pump and the mitral apparatus. No major thromboembolism was detected in the vital organs in Cases 1 or 2, but a few small renal infarcts were detected in Case 3.

  4. Long-term regulation of Na,K-ATPase pump during T-cell proliferation.

    Science.gov (United States)

    Karitskaya, Inna; Aksenov, Nikolay; Vassilieva, Irina; Zenin, Valerii; Marakhova, Irina

    2010-09-01

    The aim of the study was to elucidate the mechanism responsible for the proliferation-related regulation of Na,K-ATPase pump. Our data demonstrate that in mitogen-stimulated human blood lymphocytes, enhanced ouabain-sensitive Rb(K) fluxes in the middle/late stage of G(0)/G(1)/S transit are associated with the increased number of Na,K-ATPase pumps expressed at the cell surface (as determined by the [(3)H]ouabain binding). Analysis of total RNA (reverse transcription-polymerase chain reaction) and protein (Western blotting) showed a threefold increase in the level of Na,K-ATPase alpha1-subunit and beta1-subunit mRNAs and significant increase in the Na,K-ATPase alpha1-subunit protein during the first day of mitogen-induced proliferation. The elevated K transport as well as the increased expression of Na,K-ATPase is closely associated with the IL-2-dependent stage of T-cell response. The pharmacological inhibition of IL-2-induced MEK/ERK or JAK/STAT cascades suppressed the IL-2-induced proliferation and reduced the functional and protein expressions of Na,K-ATPase. It is concluded that during the lymphocyte transition from resting stage to proliferation, (1) long-term activation of Na,K-ATPase pump is due to the enhanced expression of Na,K-ATPase protein and mRNA, and (2) the cytokine signaling via the IL-2 receptor is necessary for the cell cycle-associated upregulation of Na,K-ATPase.

  5. The long-term stability of cement - Leaching tests

    International Nuclear Information System (INIS)

    Engkvist, I.; Albinsson, Y.; Johansson Engkvist, W.

    1996-06-01

    The concrete construction in the Swedish repository for long-lived low and intermediate level waste will give a stable chemical near field environment for 10 5 years. The pH is expected to exceed 12 for the life time for most of the radionuclides in the repository in both saline and non-saline groundwaters. This is shown by static leaching experiments performed in saline and non-saline granitic groundwater conditions. Five gram portions of crushed ordinary Portland cement paste were equilibrated with 20 ml of synthetic saline or non-saline groundwater in a nitrogen atmosphere. Each week 12 ml (60%) of the water was replaced. The withdrawn water was used for chemical analyses and the results were used to monitor the degradation of the cement paste. After eighty weeks, some samples were analysed for mineral composition and compared with the original unleached paste. The results indicated no secondary ettringite or calcite formation. The results also supported the conclusion that the salinity of the contacting water is of minor importance for the long-term performance of the cement paste. 18 refs, 32 figs

  6. Short-term consistency testing vs. long-term behavior

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Wolf, S.F.; Strachan, D.M.

    1997-01-01

    The authors conducted Product Consistency Tests (PCTs) with a surrogate low-activity waste (LAW) glass to (1) evaluate the possible use of various test conditions in a specification test for LAW waste forms, (2) measure the reproducibility of the test at low temperatures, and (3) determine if the rates calculated from 7-day PCTs bound the rates measured in PCT conducted for longer durations, which represent more advanced corrosion. The effects of temperature and pH on the dissolution rate in PCTs are much less than the effects observed in dilute solutions due to the buildup of dissolved glass components in the PCTs. The precision of replicate 7-day tests at 20 and 40 degrees C was limited by the analytical uncertainty. The dissolution rates at all temperatures decreased with the test duration initially. However, the dissolution rates in tests at 70 and 90 degrees C increased when certain alteration phases formed after about 100 and 500 days, respectively; the rates in some tests exceeded that measured in a 7-day PCT. While the 7-day PCT does not provide a bounding rate for this glass at 70 or 90 degrees C, tests for longer durations are needed to determine if a 7-day test provides a bounding rate at lower temperatures

  7. Long-term proton pump inhibitor therapy and falls and fractures in elderly women: a prospective cohort study.

    Science.gov (United States)

    Lewis, Joshua R; Barre, Deka; Zhu, Kun; Ivey, Kerry L; Lim, Ee Mun; Hughes, Jeff; Prince, Richard L

    2014-11-01

    Proton pump inhibitors (PPIs) are widely used in the elderly. Recent studies have suggested that long-term PPI therapy is associated with fractures in the elderly, however the mechanism remains unknown. We investigated the association between long-term PPI therapy ≥1 year and fracture risk factors including bone structure, falls, and balance-related function in a post hoc analysis of a longitudinal population-based prospective cohort of elderly postmenopausal women and replicated the findings in a second prospective study of falling in elderly postmenopausal women. Long-term PPI therapy was associated with increased risk of falls and fracture-related hospitalizations; adjusted odds ratio (AOR) 2.17; 95% CI, 1.25-3.77; p = 0.006 and 1.95; 95% CI, 1.20-3.16; p = 0.007, respectively. In the replication study, long-term PPI use was associated with an increased risk of self-reported falling; AOR, 1.51; 95% CI, 1.00-2.27; p = 0.049. No association of long-term PPI therapy with bone structure was observed; however, questionnaire-assessed falls-associated metrics such as limiting outdoor activity (p = 0.002) and indoor activity (p = 0.001) due to fear of falling, dizziness (p risk in subjects on long-term PPI therapy. This increase in fracture risk in elderly women, already at high risk of fracture, appears to be mediated via increased falls risk and falling rather than impaired bone structure and should be carefully considered when prescribing long-term PPI therapy. © 2014 American Society for Bone and Mineral Research.

  8. Long-Term Durability Test for the Left Ventricular Assist System EVAHEART under the Physiologic Pulsatile Load.

    Science.gov (United States)

    Kitano, Tomoya; Iwasaki, Kiyotaka

    The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.

  9. Does Off-Pump Coronary Artery Bypass Grafting Negatively Impact Long-Term Survival and Freedom from Reintervention?

    Directory of Open Access Journals (Sweden)

    Shahzad G. Raja

    2013-01-01

    Full Text Available Recently published evidence has raised concerns about worse late mortality and increasing need for reintervention after off-pump coronary artery bypass grafting. We undertook this study to assess the impact of off-pump coronary artery bypass grafting on survival and freedom from reintervention at 10 years. From January 2002 to December 2002, 307 consecutive patients who had isolated multivessel off-pump coronary artery bypass grafting at our institution were compared to a control group of 397 patients that underwent multivessel on-pump coronary artery bypass grafting during the same period. In addition, univariate and risk-adjusted comparisons between the two groups were performed at 10 years. Kaplan-Meier survival was similar for the two cohorts. After adjusting for clinical covariates, off-pump coronary artery bypass grafting did not emerge as a significant independent predictor of long-term mortality (Hazard Ratio 0.91; 95% Confidence Interval 0.70–1.12, readmission to hospital for cardiac cause (Hazard Ratio 0.96; 95% Confidence Interval 0.78–1.10, or the need for reintervention (Hazard Ratio 0.93; 95% Confidence Interval 0.87–1.05. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting does not adversely impact survival or freedom from reintervention at a 10-year follow-up.

  10. Super long-term creep tests of advanced HP and IP rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Tchizhik, A.A. [The Polzunov Central Boiler and Turbine Institute, Department the Fatigue Life of Materials for Power Plans Equipment, St. Petersburg (Russian Federation)

    1998-12-31

    A creep model has been developed for predicting the long-term creep behavior, in excess of 200,000 h for advanced materials.The new creep theory is based on a continuum microdamage model and is used to calculate the fields of stress and strain and wedge and cavities damage in critical components of steam and gas turbines. The application of this new model increases the reliability and service life of modern turbines. The accuracy of the model to predict long - term creep behavior, creep ductility was verified using the data bank of super long-term creep tests of advanced materials. (orig.) 12 refs.

  11. Super long-term creep tests of advanced HP and IP rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Tchizhik, A A [The Polzunov Central Boiler and Turbine Institute, Department the Fatigue Life of Materials for Power Plans Equipment, St. Petersburg (Russian Federation)

    1999-12-31

    A creep model has been developed for predicting the long-term creep behavior, in excess of 200,000 h for advanced materials.The new creep theory is based on a continuum microdamage model and is used to calculate the fields of stress and strain and wedge and cavities damage in critical components of steam and gas turbines. The application of this new model increases the reliability and service life of modern turbines. The accuracy of the model to predict long - term creep behavior, creep ductility was verified using the data bank of super long-term creep tests of advanced materials. (orig.) 12 refs.

  12. Equipment for long-term testing of material creep in liquid sodium

    International Nuclear Information System (INIS)

    Dufek, F.; Walder, V.; Cech, V.; Winkler, P.

    1980-01-01

    A sodium test plant is described and the methods are shown of securing the desired test specifications. The facility is used for the long-term testing of nonsteady material creep under the action of temperature and mechanical stress due to the static or pulsed overpressure of inert gas inside a tube specimen and a simultaneous effect of sodium flow on the outside wall. The test results are to be used for comparing Czechoslovak-made steels with foreign materials and also for testing the degradation effects of the above phenomena on the standardized long-term properties in inert and steady state conditions. (B.S.)

  13. Long-Term Capital Goods Importation and Minimum Wage Relationship in Turkey: Bounds Testing Approach

    Directory of Open Access Journals (Sweden)

    Tastan Serkan

    2015-04-01

    Full Text Available In order to examine the long-term relationship between capital goods importation and minimum wage, autoregressive distributed lag (ARDL bounds testing approach to the cointegration is used in the study. According to bounds test results, a cointegration relation exists between the capital goods importation and the minimum wage. Therefore an ARDL(4,0 model is estimated in order to determine the long and short term relations between variables. According to the empirical analysis, there is a positive and significant relationship between the capital goods importation and the minimum wage in Turkey in the long term. A 1% increase in the minimum wage leads to a 0.8% increase in the capital goods importation in the long term. The result is similar for short term coefficients. The relationship observed in the long term is preserved in short term, though in a lower level. In terms of error correction model, it can be concluded that error correction mechanism works as the error correction term is negative and significant. Short term deviations might be resolved with the error correction mechanism in the long term. Accordingly, approximately 75% of any deviation from equilibrium which might arise in the previous six month period will be resolved in the current six month period. This means that returning to long term equilibrium progresses rapidly.

  14. Should Helicobacter pylori be eradicated before starting long-term proton pump inhibitors?

    NARCIS (Netherlands)

    Rauws, E. A.

    1997-01-01

    Symptomatic gastro-oesophageal reflux disease is a common disorder characterized by pathological exposure of the distal oesophagus to acid. The management requires the control of symptoms, prevention of relapse and complications. Proton pump inhibitors are without doubt the most effective agents in

  15. A magnetic fluid seal for rotary blood pumps: Long-term performance in liquid

    Science.gov (United States)

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a 'shield' mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. The seal was perfect against a pressure of 150 mmHg in a continuous flow of 4.0 L/min for 275 days and against a pressure of 175 mmHg in a continuous flow of 3.9 L/min for 217 days. We have developed a MF seal that works in liquid against pressure mostly used clinically. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.

  16. A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid.

    Science.gov (United States)

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    2011-03-01

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.

  17. Advantages and Disadvantages of Long-term Proton Pump Inhibitor Use.

    Science.gov (United States)

    Kinoshita, Yoshikazu; Ishimura, Norihisa; Ishihara, Shunji

    2018-04-30

    Proton pump inhibitors (PPIs) potently inhibit gastric acid secretion and are widely used for treatment of acid-related diseases including gastroesophageal reflux disease and secondary prevention of aspirin/NSAID-induced ulcers. Although clinically important adverse effects of PPIs can occur, just as with other drugs, those are not frequently observed during or after administration. Thus, PPIs are regarded as relatively safe and considered to be clinically beneficial. Recently, PPIs have become frequently administered to patients with functional gastrointestinal diseases or primary prevention of drug-related gastroduodenal damage, even though their beneficial effects for those conditions have not been fully confirmed. PPIs tend to be given for conditions in which the necessity of the drug has not been clarified, thus otherwise rare adverse effects are presented as clinically relevant. Although several PPI-related adverse effects have been reported, their clinical relevance is not yet clear, since the evidence reported in those studies is not at a high enough level, as the majority are based on retrospective observational studies and the reported hazard ratios are low. It is important to administer PPIs only for patients who will gain a substantial clinical benefit and to continue to investigate their adverse effects with high quality prospective studies.

  18. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition

    Directory of Open Access Journals (Sweden)

    Christof eKuhbandner

    2016-02-01

    Full Text Available Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one third of the words were tested and one third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After one week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  19. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition.

    Science.gov (United States)

    Kuhbandner, Christof; Aslan, Alp; Emmerdinger, Kathrin; Murayama, Kou

    2016-01-01

    Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one-third of the words were tested and one-third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After 1 week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  20. Genetic Polymorphisms in Endothelin-1 as Predictors for Long-Term Survival and the Cardiac Index in Patients Undergoing On-Pump Cardiac Surgery.

    Directory of Open Access Journals (Sweden)

    Ashham Mansur

    Full Text Available Genetic variants within the endothelin-1 gene (EDN1 have been associated with several cardiovascular diseases and may act as genetic prognostic markers. Here, we explored the overall relevance of EDN1 polymorphisms for long-term survival in patients undergoing on-pump cardiac surgery. A prospectively collected cohort of 455 Caucasian patients who underwent cardiac surgery with cardiopulmonary bypass was followed up for 5 years. The obtained genotypes and inferred haplotypes were analyzed for their associations with the five-year mortality rate (primary endpoint. The EDN1 T-1370G and K198N genotype distributions did not deviate from Hardy-Weinberg equilibrium and the major allele frequencies were 83% and 77%, respectively. The cardiovascular risk factors were equally distributed in terms of the different genotypes and haplotypes associated with the two polymorphisms. The five-year mortality rate did not differ among the different EDN1 T-1370G and K198N genotypes and haplotypes. Haplotype analysis revealed that carriers of the G-T (compound EDN1 T-1370G G/K198N T haplotype had a higher cardiac index than did non-carriers (p = 0.0008; however, this difference did not reach significance after adjusting for multiple testing. The results indicate that common variations in EDN1 do not act as prognostic markers for long-term survival in patients undergoing on-pump cardiac surgery.

  1. Long-term kidney outcomes among users of proton pump inhibitors without intervening acute kidney injury.

    Science.gov (United States)

    Xie, Yan; Bowe, Benjamin; Li, Tingting; Xian, Hong; Yan, Yan; Al-Aly, Ziyad

    2017-06-01

    Proton pump inhibitor (PPI) use is associated with an increased risk of acute kidney injury (AKI), incident chronic kidney disease (CKD), and progression to end-stage renal disease (ESRD). PPI-associated CKD is presumed to be mediated by intervening AKI. However, whether PPI use is associated with an increased risk of chronic renal outcomes in the absence of intervening AKI is unknown. To evaluate this we used the Department of Veterans Affairs national databases to build a cohort of 144,032 incident users of acid suppression therapy that included 125,596 PPI and 18,436 Histamine H2 receptor antagonist (H2 blockers) consumers. Over 5 years of follow-up in survival models, cohort participants were censored at the time of AKI occurrence. Compared with incident users of H2 blockers, incident users of PPIs had an increased risk of an estimated glomerular filtration rate (eGFR) under 60 ml/min/1.73m 2 (hazard ratio 1.19; 95% confidence interval 1.15-1.24), incident CKD (1.26; 1.20-1.33), eGFR decline over 30% (1.22; 1.16-1.28), and ESRD or eGFR decline over 50% (1.30; 1.15-1.48). Results were consistent in models that excluded participants with AKI either before chronic renal outcomes, during the time in the cohort, or before cohort entry. The proportion of PPI effect mediated by AKI was 44.7%, 45.47%, 46.00%, and 46.72% for incident eGFR under 60 ml/min/1.73m 2 , incident CKD, eGFR decline over 30%, and ESRD or over 50% decline in eGFR, respectively. Thus, PPI use is associated with increased risk of chronic renal outcomes in the absence of intervening AKI. Hence, reliance on antecedent AKI as warning sign to guard against the risk of CKD among PPI users is not sufficient as a sole mitigation strategy. Published by Elsevier Inc.

  2. Small-Scale Testing Rig for Long-Term Cyclically Loaded Monopiles in Cohesionless Soil

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2012-01-01

    , and the period of the cyclic loading. However, the design guidance on these issues is limited. Thus, in order to investigate the pile behaviour for cyclically long-term loaded monopiles, a test setup for small-scale tests in saturated dense cohesionless soil is constructed and presented in here. The cyclic...... loading is applied mechanically by means of a testing rig, where the important input parameters: mean level, amplitude, number of cycles, and period of the loading can be varied. The results from a monotonic and a cyclic loading test on an open-ended aluminium pile with diameter = 100 mm and embedded...... length = 600 mm proves that the test setup is capable of applying the cyclic long-term loading. The plastic deformations during loading depend not only on the loading applied but also of the relative density of the soil and, thus, the tests are carried out with relative densities of 77-88%, i.e. similar...

  3. Development of Technique for Testing the Long-Term Stability of Silicon Microstrip Detectors

    International Nuclear Information System (INIS)

    Kosinov, A.V.; Maslov, N.I.; Naumov, S.V.; Ovchinnik, V.D.; Starodubtsev, A.F.; Vasiliev, G.P.; Yalovenko, V.I.; Bosisio, L.

    2006-01-01

    An automatic multi-channel set-up prototype for simultaneous testing of the Long-Term Stability (LTS) of more than ten detectors is described. The Inner Tracking System of the ALICE experiment will include about two thousand Double-sided Microstrip Detectors (DSMD). Efficient automatic measurement techniques are crucial for the LTS test, because the corresponding test procedure should be performed on each detector and requires long time, at least two days. By using special adapters for supporting and connecting the bare DSMDs, failing detectors can be screened out before module assembly, thus minimizing the cost. Automated probe stations developed for a special purpose or for microelectronics industry are used for measuring physical static DSMD characteristics and check good-to-bad elements ratio for DSMD. However, automated (or semi-automatic)test benches for studying LTS or testing DSMD long-term stability before developing a detecting module are absent

  4. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  5. Prediction of the Long Term Cooling Performance for the 3-Pin Fuel Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. K.; Chi, D. Y.; Sim, B. S.; Park, K. N.; Ahn, S. H.; Lee, J. M.; Lee, C. Y.; Kim, H. R

    2005-12-15

    In the long term cooling phase that the emergency cooling water injection ends, the performance of the residual heat removal for the 3-pin fuel test loop has been predicted by a simplified heat transfer model. In the long term cooling phase the residual heat is 1323W for PWR fuel test mode and 1449W for CANDU fuel test mode. The each residual heat is assumed as 2% of the fission power of the test fuel used in the anticipated operational occurrence and design basis accident analyses. The each fission power used for the analyses is 105% of the rated fission power in the normal operation. In the long term cooling phase the residual heat is removed to the HANARO pool through the double pressure vessels of the in-pile test section. Saturate pooling boiling is assumed on the test fuel and condensation heat transfer is expected on the inner wall of the fuel carrier and the flow divider. Natural convection heat transfer on a heated vertical wall is also assumed on the outer wall of the outer pressure vessel. The conduction heat transfer is only considered in the gap between the double pressure vessels charged with neon gas and in the downcomer filled with coolant. The heat transfer rate between the coolant temperature of 152 .deg. C in the in-pile test section and the water temperature of 45 .deg. C in the HANARO pool is predicted as about 1666W. The 152 .deg. C is the saturate temperature of the coolant pressure predicted from the MARS code. The cooling capacity of 1666W is greater than the residual heats of 1323W and 1449W. Consequently the long term cooling performance of the 3-pin fuel test loop is sufficient for the anticipated operational occurrences and design basis accidents.

  6. Data Acquisition for Low-Temperature Geothermal Well Tests and Long-Term Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P J

    1992-03-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  7. Bancroftian filariasis: long-term effect of the DEC provocative day test on microfilaraemia

    DEFF Research Database (Denmark)

    Simonsen, Poul Erik; Meyrowitsch, Dan Wolf; Makunde, W.H.

    1997-01-01

    The diethylcarbamazine (DEC) provocative day test has been widely used for daytime diagnosis of Wuchereria bancrofti infections in areas where microfilariae exhibit nocturnal periodicity. Since DEC is also the primary drug for treatment of bancroftian filariasis, we examined the long term effect...... amicrofilaraemic. No significant reduction of microfilaraemia was observed in the placebo group. The results imply that the DEC provocative day test should not be used as a diagnostic tool in follow-up studies on microfilaraemias....

  8. Data acquisition for low-temperature geothermal well tests and long-term monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-09-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  9. Patient empowerment in long-term conditions: development and preliminary testing of a new measure

    Science.gov (United States)

    2013-01-01

    Background Patient empowerment is viewed by policy makers and health care practitioners as a mechanism to help patients with long-term conditions better manage their health and achieve better outcomes. However, assessing the role of empowerment is dependent on effective measures of empowerment. Although many measures of empowerment exist, no measure has been developed specifically for patients with long-term conditions in the primary care setting. This study presents preliminary data on the development and validation of such a measure. Methods We conducted two empirical studies. Study one was an interview study to understand empowerment from the perspective of patients living with long-term conditions. Qualitative analysis identified dimensions of empowerment, and the qualitative data were used to generate items relating to these dimensions. Study two was a cross-sectional postal study involving patients with different types of long-term conditions recruited from general practices. The survey was conducted to test and validate our new measure of empowerment. Factor analysis and regression were performed to test scale structure, internal consistency and construct validity. Results Sixteen predominately elderly patients with different types of long-term conditions described empowerment in terms of 5 dimensions (identity, knowledge and understanding, personal control, personal decision-making, and enabling other patients). One hundred and ninety seven survey responses were received from mainly older white females, with relatively low levels of formal education, with the majority retired from paid work. Almost half of the sample reported cardiovascular, joint or diabetes long-term conditions. Factor analysis identified a three factor solution (positive attitude and sense of control, knowledge and confidence in decision making and enabling others), although the structure lacked clarity. A total empowerment score across all items showed acceptable levels of internal

  10. Feasibility test of the concept of long-term passive cooling system of emergency cooldown tank

    International Nuclear Information System (INIS)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Lee, Hee Joon

    2015-01-01

    Highlights: • The concept of long-term passive cooling system of emergency cooldown tank (ECT). • Existing natural circulation of steam from ECT and measurement of its condensing flow. • Evaluation of cooling capacity and heat transfer of air-cooled condensing heat exchanger. - Abstract: When a passive cooling system is activated in the accident of a nuclear reactor, the water in the emergency cooldown tank of that system will eventually be fully depleted by evaporation. If, however, the evaporating water could be returned to the tank through an air-cooled condensing heat exchanger mounted on top of the tank, the passive cooling system could provide cooling for an extended period. This feasibility of new concept of long-term passive cooling with an emergency cooldown tank was tested by performing an energy balance test with a scaled-down experimental setup. As a result, it was determined that a naturally circulating steam flow can be used to refill the tank. For an air-cooled heat exchanger, the cooling capacity and air-side natural convective heat transfer coefficient were obtained to be 37% of the heat load and between 9 and 10.2 W/m 2 /K depending on the heat load, respectively. Moreover, it was clearly verified that the water level in the emergency cooldown tank could be maintained over the long-term operation of the passive cooling system

  11. Test Plan for Long-Term Operation of a Ten-Cell High Temperature Electrolysis Stack

    International Nuclear Information System (INIS)

    James E. O'Brien; Carl M. Stoots; J. Stephen Herring

    2008-01-01

    This document defines a test plan for a long-term (2500 Hour) test of a ten-cell high-temperature electrolysis stack to be performed at INL during FY09 under the Nuclear Hydrogen Initiative. This test was originally planned for FY08, but was removed from our work scope as a result of the severe budget cuts in the FY08 NHI Program. The purpose of this test is to evaluate stack performance degradation over a relatively long time period and to attempt to identify some of the degradation mechanisms via post-test examination. This test will be performed using a planar ten-cell Ceramatec stack, with each cell having dimensions of 10 cm x 10 cm. The specific makeup of the stack will be based on the results of a series of shorter duration ten-cell stack tests being performed during FY08, funded by NGNP. This series of tests was aimed at evaluating stack performance with different interconnect materials and coatings and with or without brazed edge rails. The best performing stack from the FY08 series, in which five different interconnect/coating/edge rail combinations were tested, will be selected for the FY09 long-term test described herein

  12. Effects of Helicobacter pylori infection and long-term proton pump inhibitor use on enterochromaffin-like cells

    Science.gov (United States)

    Bektaş, Mehmet; Saraç, Nurşen; Çetinkaya, Hülya; Törüner, Murat; Erdemli, Esra; Keskin, Onur; Soykan, İrfan; Oktay, Esen Ismet; Korkut, Esin; Üstün, Yusuf; Bahar, Kadir

    2012-01-01

    Background Excessive release of gastrin leads to hypertrophy and hyperplasia of enterochromaffin-like cells (ECL) and prolonged stimulation of these cells causes functional impairment. The purpose of this study was to investigate the effect of Helicobacter pylori (H. pylori) infection and long-term proton pump inhibitors (PPI) use on ECL cells. Methods Fifteen patients who underwent endoscopy because of dyspeptic symptoms were enrolled in the present study. Biopsies were taken from corpus and antrum and existence of H. pylori was investigated with culture, cytology and CLOtest. The patients were divided into 3 groups. Group-A: H. pylori-negative, never treated previously with PPI; Group-B: H. pylori-positive, never treated previously with PPI; and group-C: H. pylori-negative and continuously treated with PPI for more than 6 months before the subject recruitment period. The features of ECL cell in oxyntic glands were examined with electron microscopy on biopsy specimens. Results ECL cells were completely normal in Group A. In group B, moderate hyperplasia and vacuolization was seen in ECL cells. In group C, ECL cell hyperplasia was observed and vacuoles with greater amounts of granules in enlarged vesicles were found more intensely in cytoplasm. Conclusion The use of PPI for a long period of time and presence of H. pylori infection are risk factors for ECL hyperplasia. PMID:24714139

  13. Long-term ETR/INTOR magnet testing in support of the demonstration fusion reactor

    International Nuclear Information System (INIS)

    Herring, J.S.; Shah, V.N.; Rouhani, S.Z.

    1983-01-01

    This study considers ways that the proposed Engineering Test Reactor (ETR), or the proposed International Tokamak Reactor (INTOR), can be used for magnet performance tests that would be useful for the design and operation of the Demonstration Tokamak Power Plant (DEMO). Such testing must not interfere with the main function of the ETR/INTOR as an integrated fusion reactor. A performance test plan for the ETR/INTOR magnets is proposed and appropriate tests on the magnets is proposed and appropriate tests on the magnets for each phase of the ETR/INTOR operation are described. The suggested tests would verify design requirements and monitor long-term changes due to radiation. This paper also summarizes the design and operational performance of existing superconducting magnets and identifies the known failures and their predominant causes

  14. Lesser Neural Pattern Similarity across Repeated Tests Is Associated with Better Long-Term Memory Retention.

    Science.gov (United States)

    Karlsson Wirebring, Linnea; Wiklund-Hörnqvist, Carola; Eriksson, Johan; Andersson, Micael; Jonsson, Bert; Nyberg, Lars

    2015-07-01

    Encoding and retrieval processes enhance long-term memory performance. The efficiency of encoding processes has recently been linked to representational consistency: the reactivation of a representation that gets more specific each time an item is further studied. Here we examined the complementary hypothesis of whether the efficiency of retrieval processes also is linked to representational consistency. Alternatively, recurrent retrieval might foster representational variability--the altering or adding of underlying memory representations. Human participants studied 60 Swahili-Swedish word pairs before being scanned with fMRI the same day and 1 week later. On Day 1, participants were tested three times on each word pair, and on Day 7 each pair was tested once. A BOLD signal change in right superior parietal cortex was associated with subsequent memory on Day 1 and with successful long-term retention on Day 7. A representational similarity analysis in this parietal region revealed that beneficial recurrent retrieval was associated with representational variability, such that the pattern similarity on Day 1 was lower for retrieved words subsequently remembered compared with those subsequently forgotten. This was mirrored by a monotonically decreased BOLD signal change in dorsolateral prefrontal cortex on Day 1 as a function of repeated successful retrieval for words subsequently remembered, but not for words subsequently forgotten. This reduction in prefrontal response could reflect reduced demands on cognitive control. Collectively, the results offer novel insights into why memory retention benefits from repeated retrieval, and they suggest fundamental differences between repeated study and repeated testing. Repeated testing is known to produce superior long-term retention of the to-be-learned material compared with repeated encoding and other learning techniques, much because it fosters repeated memory retrieval. This study demonstrates that repeated memory

  15. Mechanisms of isoform-specific Na/K pump regulation by short- and long-term adrenergic activation in rat ventricular myocytes.

    Science.gov (United States)

    Yin, Jian; Guo, Hui-Cai; Yu, Ding; Wang, Hui-Ci; Li, Jun-Xia; Wang, Yong-Li

    2014-01-01

    Many stressful conditions, including cardiovascular diseases, induce long-term elevations in circulating catecholamines, thereby leading to changes of the Na/K pump and thus affecting myocardial functions. However, only short-term adrenergic regulation of the Na/K pump has been reported. The present study is the first investigation of long-term adrenergic regulation of the Na/K pump and the potential mechanism. After acutely isolated Sprague-Dawley rat myocytes were incubated with noradrenaline or isoprenaline for 24 h, Na/K pump high- (IPH) and low-affinity current (IPL), α-isoform mRNA, and α-isoform protein were examined using patch-clamp, RT-PCR, and Western blotting techniques, respectively. After the short-term incubation, isoprenaline reduced the IPL through a PKA-dependent pathway that involves α1-isoform translocation from the membrane to early endosomes, and noradrenaline increased the IPH through a PKC-dependent pathway that involves α2-isoform translocation from late endosomes to the membrane. After long-term incubation, isoprenaline increased the IPL, α1-isoform mRNA, and α1-isoform protein, and noradrenaline reduced the IPH, α2-isoform mRNA, and α1-isoform protein through a PKA-or PKC-dependent pathway, respectively. These results suggest that long-term adrenergic Na/K pump regulation is isoform-specific and negatively feeds back on the short-term response. Furthermore, long-term regulation involves transcription and translation of the respective α-isoform, whereas short-term regulation involves the translocation of the available α-isoform to the plasma membrane. © 2014 S. Karger AG, Basel.

  16. Mechanisms of Isoform-Specific Na/K Pump Regulation by Short- and Long-Term Adrenergic Activation in Rat Ventricular Myocytes

    Directory of Open Access Journals (Sweden)

    Jian Yin

    2014-05-01

    Full Text Available Background: Many stressful conditions, including cardiovascular diseases, induce long-term elevations in circulating catecholamines, thereby leading to changes of the Na/K pump and thus affecting myocardial functions. However, only short-term adrenergic regulation of the Na/K pump has been reported. The present study is the first investigation of long-term adrenergic regulation of the Na/K pump and the potential mechanism. Methods: After acutely isolated Sprague-Dawley rat myocytes were incubated with noradrenaline or isoprenaline for 24 h, Na/K pump high- (IPH and low-affinity current (IPL, α-isoform mRNA, and α-isoform protein were examined using patch-clamp, RT-PCR, and Western blotting techniques, respectively. Results: After the short-term incubation, isoprenaline reduced the IPL through a PKA-dependent pathway that involves α1-isoform translocation from the membrane to early endosomes, and noradrenaline increased the IPH through a PKC-dependent pathway that involves α2-isoform translocation from late endosomes to the membrane. After long-term incubation, isoprenaline increased the IPL, α1-isoform mRNA, and α1-isoform protein, and noradrenaline reduced the IPH, α2-isoform mRNA, and α1-isoform protein through a PKA-or PKC-dependent pathway, respectively. Conclusions: These results suggest that long-term adrenergic Na/K pump regulation is isoform-specific and negatively feeds back on the short-term response. Furthermore, long-term regulation involves transcription and translation of the respective α-isoform, whereas short-term regulation involves the translocation of the available α-isoform to the plasma membrane.

  17. Long-term culture of undifferentiated spermatogonia isolated from immature and adult bovine testes.

    Science.gov (United States)

    Suyatno; Kitamura, Yuka; Ikeda, Shuntaro; Minami, Naojiro; Yamada, Masayasu; Imai, Hiroshi

    2018-03-01

    Undifferentiated spermatogonia eventually differentiate in the testis to produce haploid sperm. Within this cell population, there is a small number of spermatogonial stem cells (SSCs). SSCs are rare cells in the testis, and their cellular characteristics are poorly understood. Establishment of undifferentiated cell line would provide an indispensable tool for studying their biological nature and spermiogenesis/spermatogenesis in vitro. However, there have been few reports on the long-term culture of undifferentiated spermatogonia in species other than rodents. Here, we report the derivation and long-term in vitro culture of undifferentiated spermatogonia cell lines from immature and adult bovine testes. Cell lines from immature testes were maintained in serum-free culture conditions in the presence of glial-cell-line-derived neurotropic factor (GDNF) and bovine leukemia inhibitory factor (bLIF). These cell lines have embryonic stem (ES)-like cell morphology, express pluripotent-stem-cell-specific and germ-cell-specific markers at the protein and mRNA levels, and contributed to the inner cell mass (ICM) of embryos in the blastocyst stage. Meanwhile, cell lines established from adult testes were maintained in low-serum media in the presence of 6-bromoindirubin-3'-oxime (BIO). These cell lines have characteristics resembling those of previously reported male mouse germ cell lines as confirmed by their botryoidally aggregated morphology, as well as the expression of germ-cell-specific markers and pluripotent stem cell markers. These findings could be useful for the development of long-term culture of undifferentiated spermatogonia, which could aid in conservation of species and improvement of livestock production through genome editing technology. © 2018 Wiley Periodicals, Inc.

  18. The Role of Long-Term Memory in a Test of Visual Working Memory: Proactive Facilitation but No Proactive Interference

    Science.gov (United States)

    Oberauer, Klaus; Awh, Edward; Sutterer, David W.

    2017-01-01

    We report 4 experiments examining whether associations in visual working memory are subject to proactive interference from long-term memory (LTM). Following a long-term learning phase in which participants learned the colors of 120 unique objects, a working memory (WM) test was administered in which participants recalled the precise colors of 3…

  19. Design and fabrication of a unique electromechanical machine for long-term fatigue testing

    International Nuclear Information System (INIS)

    Boling, K.W.

    1984-12-01

    An electromechanical machine has been designed and fabricated for performing long-term fatigue tests under conditions that simulate those in modern plants. The machine is now commercially available. Its advantages over current electrohydraulic machines are lower initial cost, minimum maintenance requirements, and greater reliability especially when performing long tests. The machine operates in closed-loop fashion by utilizing continuous feedback signals from the specimen extensometer or load cell, it is programmable for testing in strain or load control. The maximum ram rate is 0.056 mm/s (0.134 in./min), maximum ram travel is 102 mm (4 in.) and load capacity is +-44 (+-10 kips). Induction heating controls speciment temperatures to 1000 0 C

  20. Textile for heart valve prostheses: fabric long-term durability testing.

    Science.gov (United States)

    Heim, Frederic; Durand, Bernard; Chakfe, Nabil

    2010-01-01

    The rapid developments and success in percutaneous vascular surgery over the last two decades with the now common stent grafts implantation, make the noninvasive surgery technique today attractive even for heart valve replacement. Less traumatic for the patient and also less time consuming, percutaneous heart valve replacement is however at its beginning and restricted to end of life patients. The noninvasive procedure expects from the heart valve prosthesis material to be resistant and adapted to folding requirements of the implantation process (catheter). Polyester fabric could be a suited material for heart valve implanted percutaneously. Highly flexible and resistant, polyester fabric proved to be well adapted to the dynamic behavior of a valve and polyester (Dacron) is also widely used for vascular grafts implantation and shows good biocompatibility and durability. However, today there's no data available on long-term durability of fabric used as heart valve material. The purpose of this work is to study the long term behavior of a microdenier polyester fabric construction under combined in vitro flexure and tension fatigue stress. In the novel in vitro testing technique presented, a fabric specimen was subjected to combined flexural and tensile fatigue generated by fluid flow under physiological pressure conditions. The results obtained show how flexural properties change with fatigue time, which reflects directly on the suitability of a fabric in such devices. It was also observed that these fabric structural changes directly influence the in vitro behavior of the textile heart valve prosthesis. (c) 2009 Wiley Periodicals, Inc.

  1. A ductility exhaustion evaluation of some long term creep/fatigue tests on austenitic steel

    International Nuclear Information System (INIS)

    Wood, D.S.; Wynn, J.; Austin, C.; Green, J.G.

    1988-01-01

    A limited number of long term creep/fatigue tests performed on two batches of Type 316 steel and one batch of associated 17Cr8Ni2Mo weld metal are reported. Test durations range from 5000 to 32,000 h and temperatures from 550 to 625 0 C. Subsequent metallographic examination shows the failures to be wholly or predominantly intergranular. The results are analysed using a ductility exhaustion approach and it is shown that the endurances obtained are within a factor of two of predicted values. The results confirm that the design approach to creep/fatigue currently being developed in the U.K. and based on ductility exhaustion is likely to be satisfactory. (author)

  2. Double Crowding-Out Effects of Means-Tested Public Provision for Long-Term Care

    Directory of Open Access Journals (Sweden)

    Christophe Courbage

    2015-02-01

    Full Text Available Publicly provided long-term care (LTC insurance with means-tested benefits is suspected to crowd out either private saving or informal care. This contribution predicts crowding-out effects for both private saving and informal care for policy measures designed to relieve the public purse from LTC expenditure such as more stringent means testing and increased taxation of inheritance. These effects result from the interaction of a parent who decides on the amount of saving in retirement and a caregiver who decides on the effort devoted to informal care which lowers the probability of admission to a nursing home. Double crowding-out effects are also found to be the consequence of exogenous influences, notably a higher opportunity cost of caregiving.

  3. Characterization of the effects of borehole configuration and interference with long term ground temperature modelling of ground source heat pumps

    International Nuclear Information System (INIS)

    Law, Ying Lam E.; Dworkin, Seth B.

    2016-01-01

    Highlights: • Long term ground temperature response is explored using finite element methods. • Simulation method is validated against experimental and analytical data. • Temperature changes at a fast rate in the first few years and slows down gradually. • ASHRAE recommended separation distances are not always sufficient. • Thermal accumulation occurs at the centre of borehole field. - Abstract: Ground source heat pumps (GSHPs) are an environmentally friendly alternative to conventional heating and cooling systems because of their high efficiency and low greenhouse gas emissions. The ground acts as a heat sink/source for the excess/required heat inside a building for cooling and heating modes, respectively. However, imbalance in heating and cooling needs can change ground temperature over the operating duration. This increase/decrease in ground temperature lowers system efficiency and causes the ground to foul—failing to accept or provide more heat. In order to ensure that GSHPs can operate to their designed conditions, thermal modelling is required to simulate the ground temperature during system operation. In addition, the borehole field layout can have a major impact on ground temperature. In this study, four buildings were studied—a hospital, fast-food restaurant, residence, and school, each with varying borehole configurations. Boreholes were modelled in a soil volume using finite-element methods and heating and cooling fluxes were applied to the borehole walls to simulate the GSHP operation. 20 years of operation were modelled for each building for 2 × 2, 4 × 4, and 2 × 8 borehole configurations. Results indicate that the borehole separation distance of 6 m, recommended by ASHRAE, is not always sufficient to prevent borehole thermal interactions. Benefits of using a 2 × 8 configuration as opposed to a 4 × 4 configuration, which can be observed because of the larger perimeter it provides for heat to dissipate to surrounding soil were

  4. Technical description of the NRC long-term whole-rod and crud performance test

    International Nuclear Information System (INIS)

    Einziger, R.E.; Fish, R.L.; Knecht, R.L.

    1982-09-01

    Westinghouse Hanford Company (WHC) and EG and G-Idaho are jointly conducting a long-term, low-temperature, spent-fuel, whole rod and crud behavior test to provide the Nuclear Regulatory Commission (NRC) with information to assist in the licensing of light water reactor (LWR) spent-fuel, dry storage facilities. Readily available fuel rods from an H.B. Robinson Unit 2 (PWR) fuel assembly and a Peach Bottom-II (BWR) fuel assembly were selected for use in the 50-month test. Both intact and defected rods will be tested in inert and oxidizing atmospheres. A 230 0 C test temperature was selected for the first 10-month run. Both nondestructive and destructive examinations are planned to characterize the fuel rod behavior during the 5-y test. Four interim examinations and a final examination will be conducted. Crud spallation behavior will be investigated by sampling the crud particulate from the test capsules at each of the four interim examinations and at the end of the test. The background to whole rod testing, description of rod breach mechanisms, and a detailed description of the test are presented in this document

  5. New results on long term aging tests for rad-waste container alloy selection

    International Nuclear Information System (INIS)

    Alves, H.; Wahl, V.; Ibas, O.; Stenner, F.

    2004-01-01

    The current design of containers for high level nuclear waste proceeds on using an outer barrier of corrosion resistant Ni-based super alloy. The current alloy of choice is alloy 22 (UNS N06022). It is a quaternary Ni-Cr- Mo-W alloy system. The new but well established alloy 59 (UNS N06059) is an excellent equal or even a superior alternative to alloy 22 for the 10,000 years reliability being sought. Alloy 59 is a pure ternary alloy in the Ni-Cr-Mo alloy system. Objective of this paper is to present data comparing these two alloys. Therefore the behaviour of alloy 59 and alloy 22 was characterised after aging in air for 10,000 h and 20,000 h at different temperatures (200, 300 and 427 deg. C). Since the performance of weldments is of great concern, both welded and unwelded specimens were studied. Mechanical properties of the air aged alloys were measured at room temperature by tensile and notch impact-bending test. Thermal stability and aqueous corrosion are considered to be the key issues in the long-term performance of container materials proposed for the geological disposal of high level nuclear waste. The long-term thermal stability and corrosion resistance of the alloy 59 compared to alloy 22 is discussed. Corrosion resistance was evaluated in ASTM G28 A and 'green death' solution laboratory tests; hereby corrosion rates and depth of attack were determined. Metallo-graphical studies were performed in mill annealed and air aged conditions. The results of the aging tests at 10,000 h and 20,000 h show that alloy 59 is an equal or better candidate material due to its superior localised corrosion resistance behaviour (pitting and crevice corrosion resistance) and better thermal stability needed especially in multi-pass welding of thick sections. Therefore alloy 59 seems to be the most promising alternative to alloy 22. (authors)

  6. New results on long term aging tests for rad-waste container alloy selection

    Energy Technology Data Exchange (ETDEWEB)

    Alves, H.; Wahl, V.; Ibas, O.; Stenner, F. [ThyssenKrupp VDM GmbH, Altena (Germany)

    2004-07-01

    The current design of containers for high level nuclear waste proceeds on using an outer barrier of corrosion resistant Ni-based super alloy. The current alloy of choice is alloy 22 (UNS N06022). It is a quaternary Ni-Cr- Mo-W alloy system. The new but well established alloy 59 (UNS N06059) is an excellent equal or even a superior alternative to alloy 22 for the 10,000 years reliability being sought. Alloy 59 is a pure ternary alloy in the Ni-Cr-Mo alloy system. Objective of this paper is to present data comparing these two alloys. Therefore the behaviour of alloy 59 and alloy 22 was characterised after aging in air for 10,000 h and 20,000 h at different temperatures (200, 300 and 427 deg. C). Since the performance of weldments is of great concern, both welded and unwelded specimens were studied. Mechanical properties of the air aged alloys were measured at room temperature by tensile and notch impact-bending test. Thermal stability and aqueous corrosion are considered to be the key issues in the long-term performance of container materials proposed for the geological disposal of high level nuclear waste. The long-term thermal stability and corrosion resistance of the alloy 59 compared to alloy 22 is discussed. Corrosion resistance was evaluated in ASTM G28 A and 'green death' solution laboratory tests; hereby corrosion rates and depth of attack were determined. Metallo-graphical studies were performed in mill annealed and air aged conditions. The results of the aging tests at 10,000 h and 20,000 h show that alloy 59 is an equal or better candidate material due to its superior localised corrosion resistance behaviour (pitting and crevice corrosion resistance) and better thermal stability needed especially in multi-pass welding of thick sections. Therefore alloy 59 seems to be the most promising alternative to alloy 22. (authors)

  7. Long-term product consistency test of simulated 90-19/Nd HLW glass

    International Nuclear Information System (INIS)

    Gan, X.Y.; Zhang, Z.T.; Yuan, W.Y.; Wang, L.; Bai, Y.; Ma, H.

    2011-01-01

    Chemical durability of 90-19/Nd glass, a simulated high-level waste (HLW) glass in contact with the groundwater was investigated with a long-term product consistency test (PCT). Generally, it is difficult to observe the long term property of HLW glass due to the slow corrosion rate in a mild condition. In order to overcome this problem, increased contacting surface (S/V = 6000 m -1 ) and elevated temperature (150 o C) were employed to accelerate the glass corrosion evolution. The micro-morphological characteristics of the glass surface and the secondary minerals formed after the glass alteration were analyzed by SEM-EDS and XRD, and concentrations of elements in the leaching solution were determined by ICP-AES. In our experiments, two types of minerals, which have great impact on glass dissolution, were found to form on 90-19/Nd HLW glass surface when it was subjected to a long-term leaching in the groundwater. One is Mg-Fe-rich phyllosilicates with honeycomb structure; the other is aluminosilicates (zeolites). Mg and Fe in the leaching solution participated in the formation of phyllosilicates. The main components of phyllosilicates in alteration products of 90-19/Nd HLW glass are nontronite (Na 0.3 Fe 2 Si 4 O 10 (OH) 2 .4H 2 O) and montmorillonite (Ca 0.2 (Al,Mg) 2 Si 4 O 10 (OH) 2 .4H 2 O), and those of aluminosilicates are mordenite ((Na 2 ,K 2 ,Ca)Al 2 Si 10 O 24 .7H 2 O)) and clinoptilolite ((Na,K,Ca) 5 Al 6 Si 30 O 72 .18H 2 O). Minerals like Ca(Mg)SO 4 and CaCO 3 with low solubility limits are prone to form precipitant on the glass surface. Appearance of the phyllosilicates and aluminosilicates result in the dissolution rate of 90-19/Nd HLW glass resumed, which is increased by several times over the stable rate. As further dissolution of the glass, both B and Na in the glass were found to leach out in borax form.

  8. Test plan for long-term, low-temperature oxidation of spent fuel, Series 1

    International Nuclear Information System (INIS)

    Einziger, R.E.

    1986-06-01

    Preliminary studies indicated the need for more spent fuel oxidation data in order to determine the probable behavior of spent fuel in a tuff repository. Long-term, low-temperature testing was recommended in a comprehensive technical approach to: (1) confirm the findings of the short-term thermogravimetric analyses scoping experiments; (2) evaluate the effects of variables such as burnup, atmospheric moisture and fuel type on the oxidation rate; and (3) extend the oxidation data base ot representative repository temperatures and better define the temperature dependence of the operative oxidation mechanisms. This document presents the Series 1 test plan to study, on a large number of samples, the effects of atmospheric moisture and temperature on oxidation rate and phase formation. Tests will run for up to two years, use characterized fragmented, and pulverized fuel samples, cover a temperature range of 110 0 C to 175 0 C and be conducted with an atmospheric moisture content rangeing from 0 C to approx. 80 0 C dew point. After testing, the samples will be examined and made available for leaching testing

  9. Inservice testing of vertical pumps

    International Nuclear Information System (INIS)

    Cornman, R.E. Jr.; Schumann, K.E.

    1994-01-01

    This paper focuses on the problems that may occur with vertical pumps while inservice tests are conducted in accordance with existing American Society of Mechanical Engineers Code, Section XI, standards. The vertical pump types discussed include single stage, multistage, free surface, and canned mixed flow pumps. Primary emphasis is placed on the hydraulic performance of the pump and the internal and external factors to the pump that impact hydraulic performance. In addition, the paper considers the mechanical design features that can affect the mechanical performance of vertical pumps. The conclusion shows how two recommended changes in the Code standards may increase the quality of the pump's operational readiness assessment during its service life

  10. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  11. Long-term storage life of light source modules by temperature cycling accelerated life test

    International Nuclear Information System (INIS)

    Sun Ningning; Tan Manqing; Li Ping; Jiao Jian; Guo Xiaofeng; Guo Wentao

    2014-01-01

    Light source modules are the most crucial and fragile devices that affect the life and reliability of the interferometric fiber optic gyroscope (IFOG). While the light emitting chips were stable in most cases, the module packaging proved to be less satisfactory. In long-term storage or the working environment, the ambient temperature changes constantly and thus the packaging and coupling performance of light source modules are more likely to degrade slowly due to different materials with different coefficients of thermal expansion in the bonding interface. A constant temperature accelerated life test cannot evaluate the impact of temperature variation on the performance of a module package, so the temperature cycling accelerated life test was studied. The main failure mechanism affecting light source modules is package failure due to solder fatigue failure including a fiber coupling shift, loss of cooling efficiency and thermal resistor degradation, so the Norris-Landzberg model was used to model solder fatigue life and determine the activation energy related to solder fatigue failure mechanism. By analyzing the test data, activation energy was determined and then the mean life of light source modules in different storage environments with a continuously changing temperature was simulated, which has provided direct reference data for the storage life prediction of IFOG. (semiconductor devices)

  12. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    Science.gov (United States)

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  13. Testing the effectiveness of cognitive interventions in alleviating accelerated long term forgetting (ALF).

    Science.gov (United States)

    Ricci, Monica; Wong, Toh; Nikpour, Armin; Miller, Laurie A

    2017-10-23

    It is well established that when retrieval or other forms of testing follow shortly after the acquisition of new information, long-term memory is improved in healthy subjects (Roediger & Karpicke, 2006). It is not known whether such early interventions would alleviate ALF, a condition in which early retention is normal, but there is a steep decline over longer intervals. A different behavioral intervention (i.e., an interposed recall of a story after a longer delay) was found to prevent subsequent memory loss in a single case with ALF (Jansari, Davis, McGibbon, Firminger, & Kapur, 2010; McGibbon & Jansari, 2013), but this has yet to be replicated. In the present study, we sought to test the effectiveness of early rehearsal as well as a later interposed recall on long term memory. Three men with ALF and 10 matched, healthy males (mean age = 67 yr; mean education = 15 yr) were compared for story recall following 3 early intervention conditions. There were two early rehearsal conditions: Repeated-Recall (2 additional recalls were requested in the initial 30 min interval) and Repeated Recall With Discussion (2 additional recalls plus discussion occurred in the initial 30 min interval) as well as a Control condition, in which there was no additional rehearsal in the first 30 min. Memory for 6 stories (2 in each condition) was tested at 0 min, 30 min, 1 day, 1 week and 4 weeks. In addition, to evaluate the possible sustaining effect of an additional retrieval ("booster recall") between 1 wk and 4 wk delays, 1 story from each of the early intervention conditions was recalled at 2 weeks' delay. Consistent with the profile characteristic of ALF, nonparametric statistics revealed no group differences at 0 or 30 min recalls. For Control stories, the ALF group's recall was impaired by 24 h delay. For stories in either of the early rehearsal conditions, the patients showed better retention, performing within normal limits until the 4 week recall. The "booster

  14. Long term test of buffer material. Final Report on the pilot parcels

    International Nuclear Information System (INIS)

    Karnland, Ola; Sanden, Torbjoern; Johannesson, Lars-Erik; Eriksen, Trygve E; Jansson, Mats; Wold, Susanna; Pedersen, Karsten; Motamedi, Mehrdad; Rosborg, Bo

    2000-12-01

    The 'Long Term Test of Buffer Material' (LOT) series at the Aespoe HRL aims at checking models and hypotheses for a bentonite buffer material under conditions similar to those in a KBS3 repository. The test series comprises seven test parcels, which are exposed to repository conditions for 1, 5 and 20 years. This report concerns the two completed pilot tests (1-year tests) with respect to construction, field data and laboratory results. Four research groups were engaged in this part of the project working on physical properties - mineralogy, cation diffusion, bacteria and copper corrosion, respectively. The experimental layout was to place parcels containing heater, central copper tube, pre-compacted bentonite blocks and instruments in vertical boreholes in crystalline rock. The heaters were used for simulating the decay power from spent nuclear fuel at standard KBS3 conditions (S1 parcel, 90 deg C) and to give adverse conditions (A1 parcel, 130 deg C). The latter was used in order to accelerate possible processes. Temperature, total pressure, water pressure and water content were measured during the heating period. The two pilot tests were terminated after approximately 12 months of heating, and the parcels were extracted by overlapping core drilling outside the original borehole. The entire 4.5 m long S1-parcel with approximately 20 cm rock cover was successfully lifted in one piece from the rock, whereas the central part of the A1 parcel was lost during drilling. The upper and lower parts were however retrieved. Reference and exposed bentonite material were analysed with respect to physical properties (triaxial, beam and oedometer tests), and to mineralogical properties (XRD, CEC, ICP-AES and SEM analyses) according to a defined test program. Some precipitation, mainly gypsum, was found in the warmest part of the parcels, and the only unpredicted change was minor uptake of Cu into the clay matrix. An overarching conclusion is that no degrading processes, with

  15. Long term test of buffer material. Final Report on the pilot parcels

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, Ola; Sanden, Torbjoern; Johannesson, Lars-Erik [Clay Technology AB, Lund (Sweden); Eriksen, Trygve E; Jansson, Mats; Wold, Susanna [Royal Inst. of Tech., Stockholm (Sweden); Pedersen, Karsten; Motamedi, Mehrdad [Goeteborg Univ. (Sweden); Rosborg, Bo [Studsvik Material AB, Nykoeping (Sweden)

    2000-12-01

    The 'Long Term Test of Buffer Material' (LOT) series at the Aespoe HRL aims at checking models and hypotheses for a bentonite buffer material under conditions similar to those in a KBS3 repository. The test series comprises seven test parcels, which are exposed to repository conditions for 1, 5 and 20 years. This report concerns the two completed pilot tests (1-year tests) with respect to construction, field data and laboratory results. Four research groups were engaged in this part of the project working on physical properties - mineralogy, cation diffusion, bacteria and copper corrosion, respectively. The experimental layout was to place parcels containing heater, central copper tube, pre-compacted bentonite blocks and instruments in vertical boreholes in crystalline rock. The heaters were used for simulating the decay power from spent nuclear fuel at standard KBS3 conditions (S1 parcel, 90 deg C) and to give adverse conditions (A1 parcel, 130 deg C). The latter was used in order to accelerate possible processes. Temperature, total pressure, water pressure and water content were measured during the heating period. The two pilot tests were terminated after approximately 12 months of heating, and the parcels were extracted by overlapping core drilling outside the original borehole. The entire 4.5 m long S1-parcel with approximately 20 cm rock cover was successfully lifted in one piece from the rock, whereas the central part of the A1 parcel was lost during drilling. The upper and lower parts were however retrieved. Reference and exposed bentonite material were analysed with respect to physical properties (triaxial, beam and oedometer tests), and to mineralogical properties (XRD, CEC, ICP-AES and SEM analyses) according to a defined test program. Some precipitation, mainly gypsum, was found in the warmest part of the parcels, and the only unpredicted change was minor uptake of Cu into the clay matrix. An overarching conclusion is that no degrading

  16. Long term durability tests of small engines fueled with bio-ethanol / gasoline blends

    International Nuclear Information System (INIS)

    Tippayawong, N.; Kundhawiworn, N.; Jompakdee, W.

    2006-01-01

    The paper presents the result of an ongoing research to evaluate performance and wear of small, single cylinder, naturally aspirated, agricultural spark ignition engines using biomass-derived ethanol and gasoline blends. The reference gasoline fuel was selected to be representative of gasoline typically available in Thailand. Long-term engine tests of 10% and 20% ethanol / gasoline blends as well as the reference fuel were performed at a constant speed of 2300 rpm under part load condition up to 200 operation hours for each fuel type. Engine brake power, specific fuel consumption, carbon deposits and surface wear were measured and compared between neat gasoline and ethanol/ gasoline blends. It was found that blended fuels appeared to affect the engine performance in a similar way and compared well with the base gasoline fuel. From the results obtained, it was found that engine brake power and specific fuel consumption changed slightly with running time and were not found to have any significant change between different fuel blends. There were carbon deposits buildup on the spark plug, the intake port and exhaust valve stem for all fuels used. Surface wear was not significantly different in the test engines between neat gasoline or ethanol/gasoline blend fuelling

  17. Long-term monitoring and field testing of an innovative multistory timber building

    Science.gov (United States)

    Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Kohli, Varun; Uma, S. R.

    2011-04-01

    An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of about 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The paper emphasizes the need for optimal placement of a limited number of sensors and demonstrates how this was achieved for monitoring floor vibrations with the help of the effective independence-driving point residue (EfI-DPR) technique. A novel approach to the EfI-DPR method proposed here uses a combinatorial search algorithm that increases the chances of obtaining the globally optimal solution. Finally, the results from the forced vibration tests conducted on the whole building at different construction stages are reviewed.

  18. LHCb VErtex LOcator module characterisation and long term quality assurance tests

    CERN Document Server

    Bates, A; Doherty, F; Dumps, R; Dwyer, L; Gersabeck, M; Marinho, 1, F; Melone, J; Parkes, C; Saavedra, A; Tobin, M; Viret, S

    2009-01-01

    LHCb is the dedicated b-physics experiment of the LHC. Its vertex detector, the VErtex LOcator (VELO), will operate in a harsh radiation environment with limited access due to its proximity to the LHC beam. To ensure the long term operation and performance, every module was required to pass a set of quality assurance tests. These were specifically developed for the VELO modules to take into account their operational environment and assembly steps. Each VELO module was rigorously inspected, tested and thermally cycled in the Glasgow module burn-in procedures. This paper provides details of the burn-in procedures and summarises the main results that were found. Some of the major results presented in this paper are: the full characterisation of the leakage currents; identification of bad channels; and signal to noise measurements. A few minor problems were identified through visual inspections of the modules and the feedback into the production process proved critical. As a result of the electrical and thermal t...

  19. Water Associated Zero Maze: A novel rat test for long term traumatic re-experiencing

    Directory of Open Access Journals (Sweden)

    Gilad eRitov

    2014-01-01

    Full Text Available Often, freezing and startle behaviors in the context of a previously experienced stress are taken as an indication of posttraumatic stress disorder (PTSD-like symptoms in rats. However, PTSD is characterized by large individual variations of symptoms. In order to take into consideration the complex and long term distinctive variations in effects of trauma exposure additional behavioral measures are required.The current study used a novel behavioral test, the Water Associated Zero Maze (WAZM. This test was planned to enable a formation of an association between the context of the maze and an underwater trauma or swim stress in order to examine the impact of exposure to the context which immediately precedes a stressful or a traumatic experience on rat's complex behavior. Rats were exposed to the WAZM and immediately after to an underwater trauma or short swim. One month later rats were re-exposed to the context of the WAZM while their behavior was video recorded. Furthermore, c-Fos expression in the amygdala was measured 90 min after this exposure.The results of the current study indicate that the WAZM can be used to discern behavioral changes measured a long time after the actual traumatic or stressful events. Furthermore, the behavioral changes detected were accompanied by changes of c-Fos expression in the amygdala of exposed rats. We suggest that the WAZM can be used to model traumatic memories re-experiencing in rodent models of human stress-related pathologies such as PTSD.

  20. Long-term durability testing of ceramic cross-flow filter. Final report, September 29, 1987--December 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Lippert, T.E.; Smeltzer, E.E.; Alvin, M.A.; Bachovchin, D.M.

    1993-08-01

    Long term durability testing of the cross flow filter is described. Two high temperature, high pressure test facilities were built and operated. The facilities were designed to simulate dirty gas environments typical of Pressurized Fluidized Bed Combustion (PFBC) and coal gasification. Details of the design and operation of the test facilities and filter testing results are described.

  1. Long-Term Degradation Testing of High-Temperature Electrolytic Cells

    Energy Technology Data Exchange (ETDEWEB)

    C.M. Stoots; J.E. O' Brien; J.S. Herring; G.K. Housley; D.G. Milobar; M.S. Sohal

    2009-08-01

    The Idaho National Laboratory (INL) has been researching the application of solid-oxide electrolysis cell for large-scale hydrogen production from steam over a temperature range of 800 to 900ºC. The INL has been testing various solid oxide cell designs to characterize their electrolytic performance operating in the electrolysis mode for hydrogen production. Some results presented in this report were obtained from cells, with an active area of 16 cm2 per cell. The electrolysis cells are electrode-supported, with ~10 µm thick yttria-stabilized zirconia (YSZ) electrolytes, ~1400 µm thick nickel-YSZ steam-hydrogen electrodes, and manganite (LSM) air-oxygen electrodes. The experiments were performed over a range of steam inlet mole fractions (0.1 to 0.6), gas flow rates, and current densities (0 to 0.6 A/cm2). Steam consumption rates associated with electrolysis were measured directly using inlet and outlet dewpoint instrumentation. On a molar basis, the steam consumption rate is equal to the hydrogen production rate. Cell performance was evaluated by performing DC potential sweeps at 800, 850, and 900°C. The voltage-current characteristics are presented, along with values of area-specific resistance as a function of current density. Long-term cell performance is also assessed to evaluate cell degradation. Details of the custom single-cell test apparatus developed for these experiments are also presented. NASA, in conjunction with the University of Toledo, has developed a new cell concept with the goals of reduced weight and high power density. This report presents results of the INL's testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising design for both high power-to-weight fuel cell and electrolyzer applications.

  2. Long-Term Degradation Testing of High-Temperature Electrolytic Cells

    International Nuclear Information System (INIS)

    Stoots, C.M.; O'Brien, J.E.; Herring, J.S.; Housley, G.K.; Milobar, D.G.; Sohal, M.S.

    2009-01-01

    The Idaho National Laboratory (INL) has been researching the application of solid-oxide electrolysis cell for large-scale hydrogen production from steam over a temperature range of 800 to 900 C. The INL has been testing various solid oxide cell designs to characterize their electrolytic performance operating in the electrolysis mode for hydrogen production. Some results presented in this report were obtained from cells, with an active area of 16 cm2 per cell. The electrolysis cells are electrode-supported, with ∼10 ∼m thick yttria-stabilized zirconia (YSZ) electrolytes, ∼1400 (micro)m thick nickel-YSZ steam-hydrogen electrodes, and manganite (LSM) air-oxygen electrodes. The experiments were performed over a range of steam inlet mole fractions (0.1 to 0.6), gas flow rates, and current densities (0 to 0.6 A/cm2). Steam consumption rates associated with electrolysis were measured directly using inlet and outlet dewpoint instrumentation. On a molar basis, the steam consumption rate is equal to the hydrogen production rate. Cell performance was evaluated by performing DC potential sweeps at 800, 850, and 900 C. The voltage-current characteristics are presented, along with values of area-specific resistance as a function of current density. Long-term cell performance is also assessed to evaluate cell degradation. Details of the custom single-cell test apparatus developed for these experiments are also presented. NASA, in conjunction with the University of Toledo, has developed a new cell concept with the goals of reduced weight and high power density. This report presents results of the INL's testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising design for both high power-to-weight fuel cell and electrolyzer applications.

  3. Transition from depressurization to long term cooling in AP600 scaled integral test facilities

    International Nuclear Information System (INIS)

    Bessette, D.E.; Marzo, M. di

    1999-01-01

    A novel light water reactor design called the AP600 has been proposed by the Westinghouse Electric Corporation. In the evaluation of this plant's behavior during a small break loss of coolant accident (LOCA), the crucial transition to low pressure, long-term cooling is marked by the injection of the gravitationally driven flow from the in-containment refueling water storage tank (IRWST). The onset of this injection is characterized by intermittency in the IRWST flow. This happens at a time when the reactor vessel reaches its minimum inventory. Therefore, it is important to understand and scale the behavior of the integral experimental test facilities during this portion of the transient. The explanation is that the periodic liquid drains and refills of the pressurizer are the reason for the intermittent behavior. The momentum balance for the surge line yields the nondimensional parameter controlling this process. Data from one of the three experimental facilities represent the phenomena well at the prototypical scale. The impact of the intermittent IRWST injection on the safe plant operation is assessed and its implications are successfully resolved. The oscillation is found to result from, in effect, excess water in the primary system and it is not of safety significance. (orig.)

  4. Long-term aging and loss-of-coolant accident (LOCA) testing of electrical cables

    International Nuclear Information System (INIS)

    Nelson, C.F.; Gauthier, G.; Carlin, F.

    1996-10-01

    Experiments were performed to assess the aging degradation and loss-of-coolant accident (LOCA) behavior of electrical cables subjected to long-term aging exposures. Four different cable types were tested in both the U.S. and France: (1) U.S. 2 conductor with ethylene propylene rubber (EPR) insulation and a Hypalon jacket. (2) U.S. 3 conductor with cross-linked polyethylene (XLPE) insulation and a Hypalon jacket. (3) French 3 conductor with EPR insulation and a Hypalon jacket. (4) French coaxial with polyethylene (PE) insulation and a PE jacket. The data represent up to 5 years of simultaneous aging where the cables were exposed to identical aging radiation doses at either 40 degrees C or 70 degrees C; however, the dose rate used for the aging irradiation was varied over a wide range (2-100 Gy/hr). Aging was followed by exposure to simulated French LOCA conditions. Several mechanical, electrical, and physical-chemical condition monitoring techniques were used to investigate the degradation behavior of the cables. All the cables, except for the French PE cable, performed acceptably during the aging and LOCA simulations. In general, cable degradation at a given dose was highest for the lowest dose rate, and the amount of degradation decreased as the dose rate was increased

  5. Persistent negative illness perceptions despite long-term biochemical control of acromegaly: novel application of the drawing test.

    Science.gov (United States)

    Tiemensma, Jitske; Pereira, Alberto M; Romijn, Johannes A; Broadbent, Elizabeth; Biermasz, Nienke R; Kaptein, Adrian A

    2015-05-01

    Patients with acromegaly have persistent complaints despite long-term biochemical control. Drawings can be used to assess patients' perceptions about their disease. We aimed to explore the utility of the drawing test and its relation to illness perceptions and quality of life (QoL) in patients after long-term remission of acromegaly. A cross-sectional study was conducted to evaluate the utility of the drawing test. A total of 50 patients after long-term remission (mean±s.e.m., 16±1.2 years) of acromegaly were included in this study. Patients completed the drawing test (two retrospective drawings of their body perception before acromegaly and during the active phase of acromegaly, and one drawing on the current condition after long-term remission), Illness Perception Questionnaire-Revised, Physical Symptom Checklist, EuroQoL-5D, and AcroQoL. Patients perceived a dramatic change in body size during the active state of the disease compared with the healthy state before the awareness of acromegaly. Patients reported that their body did not completely return to the original proportions after long-term remission. In addition, larger drawings indicated more negative consequences (Pdrawings also indicated more impaired QoL, especially disease-specific QoL (all Pdrawing test, illness perceptions, and QoL. The drawing test appears to be a novel and relatively easy tool to assess the perception of patients after long-term remission of acromegaly. The assessment of drawings may enable health care providers to appreciate the perceptions of patients with long-term remission of acromegaly, and enable discussion of symptoms and remission. © 2015 European Society of Endocrinology.

  6. Long-term leach testing of solidified radioactive waste forms (International Standard Publication ISO 6961:1982)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    Processes are developed for the immobilization of radionuclides by solidification of radioactive wastes. The resulting solidification products are characterized by strong resistance to leaching aimed at low release rates of the radionuclides to the environment. To measure this resistance to leaching of the solidified materials: glass, glass-ceramics, bitumen, cement, concrete, plastics, a long-term leach test is presented. The long-term leach test is aimed at: a) the comparison of different kinds or compositions of solidified waste forms; b) the intercomparison between leach test results from different laboratories on one product; c) the intercomparison between leach test results on products from different processes

  7. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  8. Influence of the dynamic Stark effect on long-term frequency stability of a self-oscillating magnetometer with laser-pumped alkali atoms

    Science.gov (United States)

    Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.

    2017-11-01

    This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.

  9. Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

    Science.gov (United States)

    Bhattacharya, Pallab

    2001-01-01

    Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

  10. Uptake of genetic testing and long-term tumor surveillance in von Hippel-Lindau disease

    Directory of Open Access Journals (Sweden)

    Chávez Mireya

    2010-01-01

    procedures in non mutation-carriers. However, mutation-carriers showed poor adherence to long-term tumor surveillance. Therefore, many of them did not obtain the full benefit of early detection and treatment, which is central to the reduction of morbidity and mortality in VHL disease. Studies designed to improve adherence to vigilance protocols will be necessary to improve treatment and quality of life in patients with hereditary cancer syndromes.

  11. Effects of Repeated Testing on Short- and Long-Term Memory Performance across Different Test Formats

    Science.gov (United States)

    Stenlund, Tova; Sundström, Anna; Jonsson, Bert

    2016-01-01

    This study examined whether practice testing with short-answer (SA) items benefits learning over time compared to practice testing with multiple-choice (MC) items, and rereading the material. More specifically, the aim was to test the hypotheses of "retrieval effort" and "transfer appropriate processing" by comparing retention…

  12. Vivitron dead section pumping tests

    International Nuclear Information System (INIS)

    Heugel, J.; Bayet, J.P.; Brandt, C.; Delhomme, C.; Krieg, C.; Kustner, F.; Meiss, R.; Riehl, R.; Roth, C.; Schlewer, B.; Six, P.; Weber, A.

    1990-10-01

    Pumping tests have been conducted on a simulated accelerator dead section. The behavior of different pump types are compared and analyzed. Vacuum conditions to be expected in the Vivitron are reached and several parameters are verified. Selection of a pump for the Vivitron dead section is confirmed

  13. Reduced volume and increased training intensity elevate muscle Na+/K+ pump {alpha}2-subunit expression as well as short- and long-term work capacity in humans

    DEFF Research Database (Denmark)

    Bangsbo, Jens; Gunnarsson, Thomas Petursson; Wendell, Jesper

    2009-01-01

    was unaltered, but the 3-K (3,000 m) time was reduced (Pexpression and performance remained unaltered in CON. The present data suggest that both short- and long-term......% reduction in the amount of training but including speed endurance training consisting of 6-12 30-s sprint runs 3-4 times a week (SET, n=12) or a control group (CON, n=5), which continued the endurance training (about 55 km(.)wk(-1)). For SET the expression of the muscle Na(+)/K(+) pump alpha2-subunit was 68...

  14. Test of a motor theory of long-term auditory memory.

    Science.gov (United States)

    Schulze, Katrin; Vargha-Khadem, Faraneh; Mishkin, Mortimer

    2012-05-01

    Monkeys can easily form lasting central representations of visual and tactile stimuli, yet they seem unable to do the same with sounds. Humans, by contrast, are highly proficient in auditory long-term memory (LTM). These mnemonic differences within and between species raise the question of whether the human ability is supported in some way by speech and language, e.g., through subvocal reproduction of speech sounds and by covert verbal labeling of environmental stimuli. If so, the explanation could be that storing rapidly fluctuating acoustic signals requires assistance from the motor system, which is uniquely organized to chain-link rapid sequences. To test this hypothesis, we compared the ability of normal participants to recognize lists of stimuli that can be easily reproduced, labeled, or both (pseudowords, nonverbal sounds, and words, respectively) versus their ability to recognize a list of stimuli that can be reproduced or labeled only with great difficulty (reversed words, i.e., words played backward). Recognition scores after 5-min delays filled with articulatory-suppression tasks were relatively high (75-80% correct) for all sound types except reversed words; the latter yielded scores that were not far above chance (58% correct), even though these stimuli were discriminated nearly perfectly when presented as reversed-word pairs at short intrapair intervals. The combined results provide preliminary support for the hypothesis that participation of the oromotor system may be essential for laying down the memory of speech sounds and, indeed, that speech and auditory memory may be so critically dependent on each other that they had to coevolve.

  15. Long-term field test of solar PV power generation using one-axis 3-position sun tracker

    KAUST Repository

    Huang, B.J.; Ding, W.L.; Huang, Y.C.

    2011-01-01

    The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand

  16. Long term deactivation test of high dust SCR catalysts by straw co-firing

    Energy Technology Data Exchange (ETDEWEB)

    Weigang Lin; Degn Jensen, A.; Bjerkvig, J.

    2009-12-15

    The consequences of carbon dioxide induced global warming cause major concern worldwide. The consumption of energy produced with fossil fuels is the major factor that contributes to the global warming. Biomass is a renewable energy resource and has a nature of CO{sub 2} neutrality. Co-combustion of biomass in existing coal fired power plants can maintain high efficiency and reduce the emission of CO{sub 2} at same time. However, one of the problems faced by co-firing is deactivation of the SCR catalysts. Understanding of the mechanisms of deactivation of the catalyst elements at co-firing conditions is crucial for long term runs of the power plants. Twenty six SCR catalyst elements were exposed at two units (SSV3 and SSV4) in the Studstrup Power Plant for a long period. Both units co-fire coal and straw with a typical fraction of 8-10% straw on an energy basis during co-firing. SSV4 unit operated in co-firing mode most of the time; SSV3 unit co-fired straw half of the operating time. The main objective of this PSO-project is to gain knowledge of a long term influence on catalyst activity when co-firing straw in coal-fired power plants, thus, to improve the basis for operating the SCR-plants for NO{sub x}-reduction. The exposure time of the applied catalyst elements (HTAS and BASF) varied from approximately 5000 to 19000 hours in the power plant by exchanging the element two times. The activity of all elements was measured before and after exposure in a bench scale test rig at the Department of Chemical and Biochemical Engineering, Technical University of Denmark. The results show that the activity, estimated by exclusion of channel clogging of the elements, decreases gradually with the total exposure time. It appears that the exposure time under co-firing condition has little effect on the deactivation of the catalyst elements and no sharp decrease of the activity was observed. The average deactivation rate of the catalyst elements is 1.6 %/1000 hours. SEM

  17. Long-term performance of colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Hassan, Cesare; Capodaglio, Giulia; Fedato, Chiara; Montaguti, Adriana; Turrin, Anna; Rosano, Alberto; Monetti, Daniele; Stocco, Carmen; Baracco, Susanna; Russo, Francesca; Repici, Alessandro; Rugge, Massimo

    2017-11-03

    The long-term performance of colorectal cancer (CRC) screening programmes based on a 2-year faecal immunochemical test (FIT) is still unclear. In a sample of 50 to 69-year-olds repeatedly screened with the FIT (OC-Hemodia latex agglutination test; cut-off: 20 µg haemoglobin/g faeces), we examined: (1) the FIT positivity rate, the CRC and advanced adenoma detection rate and the FIT's positive predictive value (PPV) for advanced neoplasia, at each round of screening and (2) the cumulative CRC and advanced adenoma detection rate after five rounds of FIT. Over 12 years (2002-2014), 123 347 individuals were administered the FIT up to six times, and 781 CRCs and 4713 advanced adenomas were diagnosed. The CRC and advanced adenoma detection rates declined substantially from the first to the third (rate ratio (RR) 0.25, 95% CI 0.20 to 0.32) and second (RR 0.51, 95% CI 0.47 to 0.56) rounds, respectively, and then remained stable. The PPV for advanced neoplasia dropped by 18% in the second round (RR 0.82, 95% CI 0.77 to 0.89), with no further reduction thereafter due to a concomitant decline in the FIT positivity rate (RR first to sixth rounds: 0.56, 95% CI 0.53 to 0.60).The cumulative CRC and advanced adenoma detection rates over five consecutive rounds were 8.5‰ (95% CI 7.8 to 9.2), and 58.9‰ (95% CI 56.9 to 61.0), respectively. Repeated FIT significantly reduces the burden of colorectal disease while facilitating an efficient use of colonoscopy resources. The cumulative detection rate after five rounds of FIT is similar to primary screening with colonoscopy, supporting the need to account for the cumulative sensitivity of repeated FITs when evaluating the test's efficacy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. The design, fabrication, and testing of WETF high-quality, long-term-storage, secondary containment vessels

    International Nuclear Information System (INIS)

    Fisher, Kane J.

    2000-01-01

    Los Alamos National Laboratory's Weapons Engineering Tritium Facility (WETF) requires secondary containment vessels to store primary tritium containment vessels. The primary containment vessel provides the first boundary for tritium containment. The primary containment vessel is stored within a secondary containment vessel that provides the secondary boundary for tritium containment. WETF requires high-quality, long-term-storage, secondary tritium containment vessels that fit within a Mound-designed calorimeter. In order to qualify the WETF high-quality, long-term-storage, secondary containment vessels for use at WETF, steps have been taken to ensure the appropriate design, adequate testing, quality in fabrication, and acceptable documentation

  19. Hyperparathyroidism Associated with Long-Term Proton Pump Inhibitors Independent of Concurrent Bisphosphonate Therapy in Elderly Adults.

    Science.gov (United States)

    Hinson, Andrew M; Wilkerson, Bekka M; Rothman-Fitts, Ivy; Riggs, Ann T; Stack, Brendan C; Bodenner, Donald L

    2015-10-01

    To measure the effect of proton pump inhibitors (PPIs), with and without concurrent bisphosphonates, on parathyroid hormone (PTH), vitamin D, and calcium. Retrospective chart review of individuals 60 years and older. Subjects with reduced renal function (creatinine >1.3 mg/dL) and low vitamin D (hyperparathyroidism regardless of concurrent oral BP administration. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  20. Persistent negative illness perceptions despite long-term biochemical control of acromegaly: novel application of the drawing test

    NARCIS (Netherlands)

    Tiemensma, Jitske; Pereira, Alberto M.; Romijn, Johannes A.; Broadbent, Elizabeth; Biermasz, Nienke R.; Kaptein, Adrian A.

    2015-01-01

    Context and objective: Patients with acromegaly have persistent complaints despite long-term biochemical control. Drawings can be used to assess patients' perceptions about their disease. We aimed to explore the utility of the drawing test and its relation to illness perceptions and quality of life

  1. A Patient on Long-Term Proton Pump Inhibitors Develops Sudden Seizures and Encephalopathy: An Unusual Presentation of Hypomagnesaemia

    Directory of Open Access Journals (Sweden)

    Nirav Y. Gandhi

    2012-01-01

    Full Text Available Objective. To present an unusual but known cause of hypomagnesaemia induced-hypocalcaemia in a chronic GORD patient with severe symptoms with a review of the current literature. Methods. Analysis of the clinical and laboratory findings of the patient and discussion of the multi-factorial nature of his disease and the underlying mechanisms. Results. Our patient described features of magnesium deficiency such as weakness, muscle twitches, and fits with clinical signs of hypocalcaemia: a carpal pedal spasm and paraesthesia. Preadmission blood results revealed low calcium and magnesium levels. He was admitted to ITU, when he presented with seizures and developed encephalopathy. The total vitamin D level was 52.4 nmol/L (>49.9. His U&Es and LFTs were within the normal range with the exception of potassium. He was on Omeprazole for his GORD. With omission of the PPI 1 day after admission and replacement therapy, his ion levels normalised. Conclusion. Hypomagnesaemia is often undiagnosed and is associated with multiple biochemical abnormalities. Treatment focus should be aimed at stopping the PPI and replacing the magnesium. Over use of PPIs is a problem in practice, with the FDA issuing a warning over long-term use. Continued monitoring and decision making on dose reduction/withdrawal is essential to avoid complications.

  2. Long-term repeatability of the skin prick test is high when supported by history or allergen-sensitivity tests

    DEFF Research Database (Denmark)

    Bødtger, Uffe; Jacobsen, C R; Poulsen, L K

    2003-01-01

    subjects. An SPT was positive when > or =3 mm, and repeatable if either persistently positive or negative. Clinical sensitivity to birch pollen was used as model for inhalation allergy, and was investigated at inclusion and at study termination by challenge tests, intradermal test, titrated SPT and Ig......E measurements. Birch pollen symptoms were confirmed in diaries. RESULTS: The repeatability of a positive SPT was 67%, increasing significantly to 100% when supported by the history. When not supported by history, the presence of specific IgE was significantly associated with a repeatable SPT. Allergen....... CONCLUSION: SPT changes are clinically relevant. Further studies using other allergens are needed. Long-term repeatability of SPT is high in the presence of a supportive history....

  3. Laboratory Testing of Solar Combi System with Compact Long Term PCM Heat Storage

    DEFF Research Database (Denmark)

    Johansen, Jakob Berg; Englmair, Gerald; Dannemand, Mark

    2016-01-01

    To enable the transition from fossil fuels as a primary heat source for domestic hot water preparation and space heating solar thermal energy has great potential. The heat from the sun has the disadvantage that it is not always available when there is a demand. To solve this mismatch a thermal...... seasonal storage can be used to store excess heat from the summer to the winter when the demand is higher than the supply. Installing a long term thermal storage in a one family house it needs to be compact and sensible heat storages are not suitable. A latent heat storage with a phase change material (PCM...

  4. Testing long-term memory in animal models of schizophrenia: suggestions from CNTRICS.

    Science.gov (United States)

    Bussey, Timothy J; Barch, Deanna M; Baxter, Mark G

    2013-11-01

    This paper reports the results of discussions at the fourth meeting of Cognitive Neuroscience Treatment Research to Improve Cognition in Schizophrenia (CNTRICS) meeting, held over two days in Washington, DC in April 2011. The meeting focused on animal paradigms for assessing the cognitive constructs relevant to schizophrenia identified in previous CNTRICS meetings. This report focuses on the outcome of discussions in the general area of long-term memory. A number of candidate animal paradigms were discussed. Two of these - one for rodents and one for non-human primates - were recommended as particularly promising for further development. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Intraindividual Variability and Long-Term Changes of Thermal Quantitative Sensory Testing

    DEFF Research Database (Denmark)

    Krøigård, Thomas; Sothynathan, Isaivani; Sindrup, Søren H

    2015-01-01

    Thermal threshold examinations are widely used in the clinical setting and in studies to assess the function of the peripheral sensory nervous system. Little is known about the variation from one side of the body to the other and the long-term temporal changes and variability. In this study, 134...... and foot. Bilateral stimulations resulted in relative intertrial variations ranging from 19% to 40%. There was no significant temporal change for repeated measures. Analysis of the individual measurements of each subject at baseline and at 26 weeks, however, resulted in relatively large intertrial...

  6. Echoic and retrieval accounts of the long-term modality effect tested using the suffix procedure.

    Science.gov (United States)

    Huang, S T; Glenberg, A M

    1986-01-01

    The long-term modality effect is the advantage in recall of the last of a list of auditory to-be-remembered (TBR) items compared with the last of a list of visual TBR items when the list is followed by a filled retention interval. If the auditory advantage is due to echoic sensory memory mechanisms, then recall of the last auditory TBR item should be substantially reduced when it is followed by a redundant, not-to-be-recalled auditory suffix. Contrary to this prediction, Experiment 1 demonstrated that a redundant auditory suffix does not significantly reduce recall of the last auditory TBR item. In Experiment 2 a nonredundant auditory suffix produced a large reduction in the last auditory item. Redundancy is not the only factor controlling the effectiveness of a suffix, however. Experiment 3 demonstrated that a nonredundant visual suffix does not reduce recall of the last auditory TBR item. These results are discussed in reference to a retrieval account of the long-term modality effect.

  7. Long Term Osmotic Mini Pump Treatment with Alpha-MSH Improves Myocardial Function in Zucker Diabetic Fatty Rats

    Directory of Open Access Journals (Sweden)

    Miklos Szokol

    2017-10-01

    Full Text Available The present investigation evaluates the cardiovascular effects of the anorexigenic mediator alpha-melanocyte stimulating hormone (MSH, in a rat model of type 2 diabetes. Osmotic mini pumps delivering MSH or vehicle, for 6 weeks, were surgically implanted in Zucker Diabetic Fatty (ZDF rats. Serum parameters, blood pressure, and weight gain were monitored along with oral glucose tolerance (OGTT. Echocardiography was conducted and, following sacrifice, the effects of treatment on ischemia/reperfusion cardiac injury were assessed using the isolated working heart method. Nicotinamide adenine dinucleotide phosphate (NADPH oxidase activity was measured to evaluate levels of oxidative stress, and force measurements were performed on isolated cardiomyocytes to determine calcium sensitivity, active tension and myofilament co-operation. Vascular status was also evaluated on isolated arterioles using a contractile force measurement setup. The echocardiographic parameters ejection fraction (EF, fractional shortening (FS, isovolumetric relaxation time (IVRT, mitral annular plane systolic excursion (MAPSE, and Tei-index were significantly better in the MSH-treated group compared to ZDF controls. Isolated working heart aortic and coronary flow was increased in treated rats, and higher Hill coefficient indicated better myofilament co-operation in the MSH-treated group. We conclude that MSH improves global heart functions in ZDF rats, but these effects are not related to the vascular status.

  8. Development of a mechanical testing and loading system for trabecular bone studies for long term culture

    Directory of Open Access Journals (Sweden)

    DB Jones

    2003-03-01

    Full Text Available A highly accurate (�3% mechanical loading and measurement system combined with a trabecular bone diffusion culture-loading chamber has been developed, which provides the ability to study trabecular bone (and possibly cartilage under controlled culture and loading conditions over long periods of time. The loading device has been designed to work in two main modes, either to apply a specific compressive strain to a trabecular bone cylinder or to apply a specific force and measure the resulting deformation. Presently, precisely machined bone cylinders can be loaded at frequencies between 0.1 Hz to 50 Hz and amplitudes over 7,000�e. The system allows accurate measurement of many mechanical properties of the tissue in real time, including visco-elastic properties. This paper describes the technical components, reproducibility, precision, and the calibration procedures of the loading system. Data on long term culture and mechanical responses to different loading patterns will be published separately.

  9. Testing causes for long-term changes in carbon cycling and climate during the early Paleogene

    Science.gov (United States)

    Komar, N.; Zeebe, R. E.; Dickens, G. R.

    2013-12-01

    The late Paleocene to the early Eocene (˜58-52 Ma) was marked by significant changes in global climate and carbon cycling. Among the evidence for these changes, stable isotope records reveal a prominent decrease of δ13C and δ18O (in both surface and deep ocean), indicating a reorganization in the long-term global carbon cycle and a long-term warming trend (˜4°C), respectively. Concurrently, deep-sea carbonate records at several sites indicate a deepening of the calcite compensation depth (CCD). Here, we investigate possible causes (e.g., increased volcanic degassing, decreased net organic burial, and accelerated dissociation of gas hydrate) for these observations, but from a new perspective. The basic model employed is a modified version of GEOCARB III. However, we have coupled this well-known geochemical model to LOSCAR, a model that enables simulation of seawater carbonate chemistry, the CCD, and ocean δ13C. We have also added a gas hydrate capacitor that can account for the storage and release of methane from the seafloor over millions of years. We further consider accurate input data (e.g., δ13C of carbonate) on a currently accepted time scale that spans an interval much longer than the perturbation. Several different scenarios are investigated with the goal of consistency amongst inferred changes in temperature, the CCD, and surface ocean and deep ocean δ13C. The results strongly suggest that a decrease in net organic carbon burial drove carbon cycle changes during the late Paleocene and early Eocene, although an increase in volcanic activity might have contributed. Importantly, a drop in net organic carbon burial may represent increased oxidation of previously deposited organic carbon, such as stored in peat or gas hydrates. The model successfully recreates trends in Earth surface warming, as inferred from δ18O records, the CCD, and δ13C. At the moment, however, our coupled modeling effort cannot reproduce the magnitude of change in all these

  10. Investigation of Loop Seal Clearing Phenomena for the ATLAS SBLOCA Long Term Cooling Test using TRACE and MARS-KS

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Min Jeong; Park, M. H.; Marigomen Ralph; Sim, S. K. [Environment and Energy Technology, Daejeon (Korea, Republic of)

    2016-10-15

    During Design Certificate(DC) review of the APR1400, USNRC raised a long term cooling safety issue on the effect of loop seal clearing during cold leg Small Break Loss Of Coolant Accident(SBLOCA) due to relatively deep cross-over loop compared to the US PWRs. The objective of this study is thus to investigate the loop seal clearing phenomena during cold leg slot break SBLOCA long term cooling and resolve the safety issue on the SBLOCA long term cooling related to the APR1400 DC. TRACE and MARS-KS were used to predict the test results and to perform sensitivity studies for the SBLOCA loop seal clearing phenomena. The calculation shows that the TRACE code well predict the sequence of Test LTC-CL-04R. However, compared to the experiment, the TRACE over predicts the primary pressure due to smaller break flow prediction. MARS-KS well predicts major thermal hydraulic parameters during the transient with reasonable agreement. MARS-KS better predicts ATLAS LTC-CL-04R test data with a good agreement than the TRACE due to better prediction of the break flow. Overall, compared to the experiment, the TRACE and MARS-KS Codes show a discrepancy in predicting the loop seal clearing and reformation time. Both TRACE and MARS-KS correctly predicts core water level and fuel cladding temperatures. From this study, it can be said that even though APR1400 cross-over leg design has slightly deeper loop seals, the effect on the safety of the SBLOCA long term cooling is minimal compared to the SBLOCA cladding failure criteria. Further study on the SBLOCA loop seal clearing phenomena is needed.

  11. Long-term Monitoring Plan for the Shoal Underground Nuclear Test

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed Hassan

    2005-02-01

    The flow and transport model of Shoal is used to design a three-well monitoring network to be part of the long-term monitoring network for the site and achieve two objectives: (1) detect the presence of radionuclides in case they migrate to the monitoring well locations, and (2) provide field data to compare with model predictions as part of the model validation process. Using three different quantitative approaches and the numerical groundwater flow and transport model developed for Shoal, three new monitoring well locations were identified from 176 different networks. In addition to the quantitative analyses using the numerical model, the development of the monitoring network for Shoal will also be subject to qualitative hydrogeologic interpretation during implementation. information will only be available during the fieldwork, it will be incorporated in the monitoring well design at the time of well installation. Finally, it should be noted that the CADD-CAP for Shoal, including the compliance boundary, is not yet approved. Should the compliance boundary change from the 1,000-year MCL contaminant boundary, well locations may also need to change. However, the analysis reported here provides a number of alternatives with reasonable detection efficiency.

  12. Long-term Monitoring Plan for the Shoal Underground Nuclear Test

    International Nuclear Information System (INIS)

    Ahmed Hassan

    2005-01-01

    The flow and transport model of Shoal is used to design a three-well monitoring network to be part of the long-term monitoring network for the site and achieve two objectives: (1) detect the presence of radionuclides in case they migrate to the monitoring well locations, and (2) provide field data to compare with model predictions as part of the model validation process. Using three different quantitative approaches and the numerical groundwater flow and transport model developed for Shoal, three new monitoring well locations were identified from 176 different networks. In addition to the quantitative analyses using the numerical model, the development of the monitoring network for Shoal will also be subject to qualitative hydrogeologic interpretation during implementation. information will only be available during the fieldwork, it will be incorporated in the monitoring well design at the time of well installation. Finally, it should be noted that the CADD-CAP for Shoal, including the compliance boundary, is not yet approved. Should the compliance boundary change from the 1,000-year MCL contaminant boundary, well locations may also need to change. However, the analysis reported here provides a number of alternatives with reasonable detection efficiency

  13. Diesel fuel long term storage and treatment- recommended tests and practices (U)

    Energy Technology Data Exchange (ETDEWEB)

    Gross, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2009-06-05

    The Clean Air Act (1970) is the comprehensive federal law that regulates air emissions from stationary and mobile sources. Among other things, this law authorized the Environmental Protection Agency (EPA) to establish National Ambient Air Quality Standards to protect public health and public welfare and to regulate emissions of hazardous air pollutants. In recent years, EPA regulations have forced oil refineries into producing a very low sulfur diesel fuel and incentives for adding up to 5% bio-diesel. These changes to the fuel oil formulation are beneficial to air quality and to energy conservation, but adversely impact heat content, long term storage stability, engine power, and injection system reliability. Diesel engines typically have a high incidence of injector failure resulting from poor diesel fuel quality. Since standby diesel engines do not run continuously it is necessary to implement periodic surveillance's to ensure the quality of diesel fuel is acceptable for reliable operation when a loss of power occurs. The information contained in this document is a compilation of best practices to be used as a guide for maintenance of a reliable diesel fuel system.

  14. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    Science.gov (United States)

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  15. Usefulness of a 50-meter round walking test for fall prediction in the elderly requiring long-term care

    Science.gov (United States)

    Hachiya, Mizuki; Murata, Shin; Otao, Hiroshi; Ihara, Takehiko; Mizota, Katsuhiko; Asami, Toyoko

    2015-01-01

    [Purpose] This study aimed to verify the usefulness of a 50-m round walking test developed as an assessment method for walking ability in the elderly. [Subjects] The subjects were 166 elderly requiring long-term care individuals (mean age, 80.5 years). [Methods] In order to evaluate the factors that had affected falls in the subjects in the previous year, we performed the 50-m round walking test, functional reach test, one-leg standing test, and 5-m walking test and measured grip strength and quadriceps strength. [Results] The 50-m round walking test was selected as a variable indicating fall risk based on the results of multiple logistic regression analysis. The cutoff value of the 50-m round walking test for determining fall risk was 0.66 m/sec. The area under the receiver operating characteristic curve was 0.64. The sensitivity of the cutoff value was 65.7%, the specificity was 63.6%, the positive predictive value was 55.0%, the negative predictive value was 73.3%, and the accuracy was 64.5%. [Conclusion] These results suggest that the 50-m round walking test is a potentially useful parameter for the determination of fall risk in the elderly requiring long-term care. PMID:26834327

  16. Results on long-term performances and laboratory tests of the L3 RPC system at LEP

    CERN Document Server

    Alviggi, M G; Conventi, F; De Asmundis, R; Della Pietra, M; Della Volpe, D; Patricelli, S; Paolucci, P; Piccolo, D; Sciacca, C; Sekhniaidze, G

    2003-01-01

    The RPC detectors in the L3 experiment at LEP work as a trigger system for the Forward-Backward Muon Spectrometer. It consists of 192 bi-gap RPCs working in streamer mode. We monitored the behaviour of the system over seven years of data taking at LEP. To investigate the ageing of the RPCs after this long-term operation, we report the main results obtained from 1994 to 2000, together with the results of tests performed on some RPC chambers in our test site in Napoli with cosmic rays after the dismantling of L3.

  17. Tests of US rock salt for long-term stability of CAES reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Gehle, R.M.; Thoms, R.L.

    1986-01-01

    This is a report on laboratory tests to assess the effects of compressed air energy storage (CAES) on rock salt within the US. The project included a conventional laboratory test phase, with triaxial test machines, and a bench-scale test phase performed in salt mines in southern Louisiana. Limited numerical modeling also was performed to serve as a guide in selecting test layouts and for interpreting test data.

  18. Modelling of degradation processes in creep resistant steels through accelerated creep tests after long-term isothermal ageing

    Energy Technology Data Exchange (ETDEWEB)

    Sklenicka, V.; Kucharova, K.; Svoboda, M.; Kroupa, A.; Kloc, L. [Academy of Sciences of the Czech Republic, Brno (Czech Republic). Inst. of Physics of Materials; Cmakal, J. [UJP PRAHA a.s., Praha-Zbraslav (Czech Republic)

    2010-07-01

    Creep behaviour and degradation of creep properties of creep resistant materials are phenomena of major practical relevance, often limiting the lives of components and structures designed to operate for long periods under stress at elevated and/or high temperatures. Since life expectancy is, in reality, based on the ability of the material to retain its high-temperature creep strength for the projected designed life, methods of creep properties assessment based on microstructural evolution in the material during creep rather than simple parametric extrapolation of short-term creep tests are necessary. In this paper we will try to further clarify the creep-strength degradation of selected advanced creep resistant steels. In order to accelerate some microstructural changes and thus to simulate degradation processes in long-term service, isothermal ageing at 650 C for 10 000 h was applied to P91 and P23 steels in their as-received states. The accelerated tensile creep tests were performed at temperature 600 C in argon atmosphere on all steels both in the as-received state and after long-term isothermal ageing, in an effort to obtain a more complete description of the role of microstructural stability in high temperature creep of these steels. Creep tests were followed by microstructural investigations by means of both transmission and scanning electron microscopy and by the thermodynamic calculations. The applicability of the accelerated creep tests was verified by the theoretical modelling of the phase equilibria at different temperatures. It is suggested that under restructed oxidation due to argon atmosphere microstructural instability is the main detrimental process in the long-term degradation of the creep rupture strength of these steels. (orig.)

  19. Constrained prose recall and the assessment of long-term forgetting: the case of ageing and the Crimes Test.

    Science.gov (United States)

    Baddeley, Alan; Rawlings, Bruce; Hayes, Amie

    2014-01-01

    It has become increasingly clear that some patients with apparently normal memory may subsequently show accelerated long-term forgetting (ALF), with dramatic loss when retested. We describe a constrained prose recall task that attempts to lay the foundations for a test suitable for detecting ALF sensitively and economically. Instead of the usual narrative structure of prose recall tests, it employs a matrix structure involving four episodes, each describing a minor crime, with each crime involving the binding into a coherent episode of a specified range of features, involving the victim, the crime, the criminal and the location, allowing a total of 80 different probed recall questions to be generated. These are used to create four equivalent 20-item tests, three of which are used in the study. After a single verbal presentation, young and elderly participants were tested on three occasions, immediately, and by telephone after a delay of 6 weeks, and at one of a varied range of intermediate points. The groups were approximately matched on immediate test; both showed systematic forgetting which was particularly marked in the elderly. We suggest that constrained prose recall has considerable potential for the study of long-term forgetting.

  20. Long-term field test of solar PV power generation using one-axis 3-position sun tracker

    KAUST Repository

    Huang, B.J.

    2011-09-01

    The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand-alone solar-powered LED lighting systems. The field test in the particular days shows that the 1A-3P tracking PV can generate 35.8% more electricity than the fixed PV in a partly-cloudy weather with daily-total solar irradiation HT=11.7MJ/m2day, or 35.6% in clear weather with HT=18.5MJ/m2day. This indicates that the present 1A-3P tracking PV can perform very close to a dual-axis continuous tracking PV (Kacira et al., 2004). The long-term outdoor test results have shown that the increase of daily power generation of 1A-3P tracking PV increases with increasing daily-total solar irradiation. The increase of monthly-total power generation for 1A-3P sun tracking PV is between 18.5-28.0%. The total power generation increase in the test period from March 1, 2010 to March 31, 2011, is 23.6% in Taipei (an area of low solar energy resource). The long-term performance of the present 1X-3P tracking PV is shown very close to the 1-axis continuous tracking PV in Taiwan (Chang, 2009). If the 1A-3P tracking PV is used in the area of high solar energy resource with yearly-average HT>17MJ/m2day, the increase of total long-term power generation with respect to fixed PV will be higher than 37.5%. This is very close to that of dual-axis continuous tracking PV. The 1A-3P tracker can be easily mounted on the wall of a building. The cost of the whole tracker is about the same as the regular mounting cost of a conventional rooftop PV system. This means that there is no extra cost for 1A-3P PV mounted on buildings. The 1A-3P PV is quite suitable for building-integrated applications. © 2011 Elsevier Ltd.

  1. Experimental Testing of Monopiles in Sand Subjected to One-Way Long-Term Cyclic Lateral Loading

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2013-01-01

    In the offshore wind turbine industry the most widely used foundation type is the monopile. Due to the wave and wind forces the monopile is subjected to a strong cyclic loading with varying amplitude, maximum loading level, and varying loading period. In this paper the soil–pile interaction...... of a monopile in sand subjected to a long-term cyclic lateral loading is investigated by means of small scale tests. The tests are conducted with a mechanical loading rig capable of applying the cyclic loading as a sine signal with varying amplitude, mean loading level, and loading period for more than 60 000...... cycles. The tests are conducted in dense saturated sand. The maximum moment applied in the cyclic tests is varied from 18% to 36% of the ultimate lateral resistance found in a static loading test. The tests reveal that the accumulated rotation can be expressed by use of a power function. Further, static...

  2. Evaluation and testing of metering pumps for high-level nuclear waste slurries

    International Nuclear Information System (INIS)

    Peterson, M.E.; Perez, J.M. Jr.; Blair, H.T.

    1986-06-01

    The metering pump system that delivers high-level liquid wastes (HLLW) slurry to a melter is an integral subsystem of the vitrification process. The process of selecting a pump for this application began with a technical review of pumps typically used for slurry applications. The design and operating characteristics of numerous pumps were evaluated against established criteria. Two pumps, an air-displacement slurry (ADS) pump and an air-lift pump, were selected for further development. In the development activity, from FY 1983 to FY 1985, the two pumps were subjected to long-term tests using simulated melter feed slurries to evaluate the pumps' performances. Throughout this period, the designs of both pumps were modified to better adapt them for this application. Final reference designs were developed for both the air-displacement slurry pump and the air-lift pump. Successful operation of the final reference designs has demonstrated the feasibility of both pumps. A fully remote design of the ADS pump has been developed and is currently undergoing testing at the West Valley Demonstration Project. Five designs of the ADS pump were tested and evaluated. The initial four designs proved the operating concept of the ADS pump. Weaknesses in the ADS pump system were identified and eliminated in later designs. A full-scale air-lift pump was designed and tested as a final demonstration of the air-lift pump's capabilities

  3. Long term test of buffer material at the Aespoe HRL, LOT project. Final report on the A0 test parcel

    International Nuclear Information System (INIS)

    Karnland, Ola; Olsson, Siv; Sanden, Torbjoern; Faelth, Billy; Jansson, Mats; Eriksen, Trygve E.; Svaerdstroem, Kjell; Rosborg, Bo; Muurinen, Arto

    2011-02-01

    In the Swedish repository concept for nuclear waste (KBS-3 concept), the spent nuclear fuel will be stored in copper canisters surrounded by compacted bentonite. The decaying power of the fuel will increase the temperature in the repository which, in combination with the uptake of ground-water, could be expected to produce minor mineralogical changes in the bentonite. The ongoing LOT test series at the Aespoe Hard Rock Laboratory are focused on identifying and quantifying any mineralogical alterations in the bentonite exposed to typical repository-like conditions. Further, buffer-related processes concerning copper corrosion, cation transport, and bacterial survival/activity are studied. In total, the LOT project includes seven test parcels, which contain a central Cu-tube surrounded by cylindrical bentonite blocks to a total diameter of 30 cm as well as temperature, total pressure, water pressure and humidity sensors. In each test parcel, an electrical heater placed inside the copper tube is used to simulate the heat generation from the decaying spent fuel. Three test parcels (S1 to S3) have been exposed to standard KBS-3 conditions (maximum temperature below 100 deg C) and three parcels (A1 to A3) to adverse conditions (maximum temperature below ∼140 deg C). Both the standard and the adverse test series include short term tests (1 to 2 years), medium term tests (> 5 years) and long term tests (> 10 years). The present report concerns an additional short term test, thereby the designation A0, which was exposed to adverse conditions for approximately 1.5 years. Cu-coupons, 134 Cs and 57 Co tracers and specific chemical agents were placed in the bentonite at defined positions. After field exposure, the entire test parcel was released from the rock by overlapping percussion drilling and wire sawing. The parcel was lifted and divided at the test site and the bentonite material was sampled for specified analyses. The main aspects of the various tests and analyses may

  4. Long term test of buffer material at the Aespoe HRL, LOT project. Final report on the A0 test parcel

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, Ola; Olsson, Siv; Sanden, Torbjoern; Faelth, Billy (Clay Technology AB, Lund (Sweden)); Jansson, Mats; Eriksen, Trygve E.; Svaerdstroem, Kjell (KTH Royal Inst. of Technology, Stockholm (Sweden)); Rosborg, Bo (Studsvik AB, Nykoeping (Sweden); Rosborg Consulting, Nykoeping (Sweden)); Muurinen, Arto (VTT, Espoo (Finland))

    2011-02-15

    In the Swedish repository concept for nuclear waste (KBS-3 concept), the spent nuclear fuel will be stored in copper canisters surrounded by compacted bentonite. The decaying power of the fuel will increase the temperature in the repository which, in combination with the uptake of ground-water, could be expected to produce minor mineralogical changes in the bentonite. The ongoing LOT test series at the Aespoe Hard Rock Laboratory are focused on identifying and quantifying any mineralogical alterations in the bentonite exposed to typical repository-like conditions. Further, buffer-related processes concerning copper corrosion, cation transport, and bacterial survival/activity are studied. In total, the LOT project includes seven test parcels, which contain a central Cu-tube surrounded by cylindrical bentonite blocks to a total diameter of 30 cm as well as temperature, total pressure, water pressure and humidity sensors. In each test parcel, an electrical heater placed inside the copper tube is used to simulate the heat generation from the decaying spent fuel. Three test parcels (S1 to S3) have been exposed to standard KBS-3 conditions (maximum temperature below 100 deg C) and three parcels (A1 to A3) to adverse conditions (maximum temperature below approx140 deg C). Both the standard and the adverse test series include short term tests (1 to 2 years), medium term tests (> 5 years) and long term tests (> 10 years). The present report concerns an additional short term test, thereby the designation A0, which was exposed to adverse conditions for approximately 1.5 years. Cu-coupons, 134Cs and 57Co tracers and specific chemical agents were placed in the bentonite at defined positions. After field exposure, the entire test parcel was released from the rock by overlapping percussion drilling and wire sawing. The parcel was lifted and divided at the test site and the bentonite material was sampled for specified analyses. The main aspects of the various tests and analyses

  5. Long-term job insecurity, job satisfaction and organisational attitudes: Test of Warr’s Curvilinear Hypothesis

    Directory of Open Access Journals (Sweden)

    Hans De Witte

    2005-10-01

    Full Text Available Research suggests that job insecurity is an important work stressor, negatively affecting well-being and organisational attitudes and behaviours. This article concentrates on two often ignored issues in this field. First, the consequences of long-term job insecurity regarding job satisfaction, the evaluation of management and organisational attitudes are analysed. Secondly, Warr’s assumption of curvilinear associations between job insecurity and well-being is tested, and extended to the evaluation of management and organisational attitudes. The hypotheses are tested with data of 769 employees from various branches of a large European multinational company. In total, 15 reliable scales were used to test the hypotheses. The results show that 48,2% of the interviewees had worries about their long-term job security. Separate analyses of variance showed that long-term job insecurity was associated with two thirds of the scales. Long-term job insecurity was associated with lower job satisfaction, lower organisational attitudes and a lower evaluation of supervisors and management. Warr’s assumption of curvilinear associations with job insecurity was not corroborated, however. Suggestions for practice and for future research are discussed. Opsomming Navorsing stel voor dat werksonsekerheid ’n belangrike werk stressor is en dat dit welstand, organisasie gesindhede en gedrag negetief affekteer. Die artikel konsentreer op twee onderwerpe in hierdie veld wat gereeld geignoreer word. Eerstens word die gevolge van langtermyn werksonsekerheid met betrekking tot werkstevredenheid, die evaluering van bestuur en organisasiegesindhede geanaliseer. Tweedens, is Warr se aanames van kromlynige verhoudings tussen werksonsekerheid en welstand getoets, en uitgebrei tot die evaluasie van bestuur en organisasiegesindhede. Die hipotese is getoets met data van 769 werknemers van verskeie takke van ’n groot Europese multinasionale maatskappy. Daar is in totaal 15

  6. Military chemical warfare agent human subjects testing: part 2--long-term health effects among participants of U.S. military chemical warfare agent testing.

    Science.gov (United States)

    Brown, Mark

    2009-10-01

    Military chemical warfare agent testing from World War I to 1975 produced thousands of veterans with concerns about how their participation affected their health. A companion article describes the history of these experiments, and how the lack of clinical data hampers evaluation of long-term health consequences. Conversely, much information is available about specific agents tested and their long-term health effects in other populations, which may be invaluable for helping clinicians respond effectively to the health care and other needs of affected veterans. The following review describes tested agents and their known long-term health consequences. Although hundreds of chemicals were tested, they fall into only about a half-dozen pharmaceutical classes, including common pharmaceuticals; anticholinesterase agents including military nerve agents and pesticides; anticholinergic glycolic acid esters such as atropine; acetylcholine reactivators such as 2-PAM; psychoactive compounds including cannabinoids, phencyclidine, and LSD; and irritants including tear gas and riot control agents.

  7. Non-destructive testing on aramid fibres for the long-term assessment of interventions on heritage structures

    International Nuclear Information System (INIS)

    Ceravolo, R; Pinotti, E; Surace, C; Fragonara, L Zanotti; De Marchi, A

    2015-01-01

    High strength fibre reinforced polymers (FRPs) are composite materials made of fibres such as carbon, aramid and/or glass, and a resin matrix. FRPs are commonly used for structural repair and strengthening interventions and exhibit high potential for applications to existing constructions, including heritage buildings. In regard to aramid fibres, uncertainties about the long-term behaviour of these materials have often made the designers reluctant to use them in structural engineering. The present study describes simple and non-destructive nonlinearity tests for assessing damage or degradation of structural properties in Kevlar fibres. This was obtained by using high precision measurements to detect small deviations in the dynamic response measured on fibres and ropes. The change in dynamic properties was then related to a damage produced by exposure of the sample to UV rays for a defined time period, which simulated long-term sun exposure. In order to investigate the sensitivity of such an approach to damage detection, non-linearity characterisation tests were conducted on aramid fibres in both damaged and undamaged states. With the purpose of carrying out dynamic tests on small fibre specimens, a dedicated instrumentation was designed and built in cooperation with the Metrology Laboratory of the Department of Electronics at the Politecnico di Torino. (paper)

  8. Integrated Corrosion Facility for long-term testing of candidate materials for high-level radioactive waste containment

    International Nuclear Information System (INIS)

    Estill, J.C.; Dalder, E.N.C.; Gdowski, G.E.; McCright, R.D.

    1994-10-01

    A long-term-testing facility, the Integrated Corrosion Facility (I.C.F.), is being developed to investigate the corrosion behavior of candidate construction materials for high-level-radioactive waste packages for the potential repository at Yucca Mountain, Nevada. Corrosion phenomena will be characterized in environments considered possible under various scenarios of water contact with the waste packages. The testing of the materials will be conducted both in the liquid and high humidity vapor phases at 60 and 90 degrees C. Three classes of materials with different degrees of corrosion resistance will be investigated in order to encompass the various design configurations of waste packages. The facility is expected to be in operation for a minimum of five years, and operation could be extended to longer times if warranted. A sufficient number of specimens will be emplaced in the test environments so that some can be removed and characterized periodically. The corrosion phenomena to be characterized are general, localized, galvanic, and stress corrosion cracking. The long-term data obtained from this study will be used in corrosion mechanism modeling, performance assessment, and waste package design. Three classes of materials are under consideration. The corrosion resistant materials are high-nickel alloys and titanium alloys; the corrosion allowance materials are low-alloy and carbon steels; and the intermediate corrosion resistant materials are copper-nickel alloys

  9. Comparison of accelerated pavement test results with long term pavement behaviour and performance

    CSIR Research Space (South Africa)

    Jooste, FJ

    1997-08-01

    Full Text Available The aim of this study was to investigate the following:how accelerated pavement testing predictions compare with actual road behaviour and performance the relative influences of load and environmental factors on pavement deterioration and how well...

  10. Test setup for long term reliability investigation of Silicon Carbide MOSFETs

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Beczkowski, Szymon

    2013-01-01

    Silicon Carbide MOSFETs are now widely available and have frequently been demonstrated to offer numerous advantages over Silicon based devices. However, reliability issues remain a significant concern in their realisation in commercial power electronic systems. In this paper, a test bench...... is designed that enables an accelerated power cycling test to be performed on packaged Silicon Carbide MOSFETs (TO-247) under realistic operating conditions. An accelerated power cycling test is then performed, with on-state resistance selected as the observed parameter to detect degradation. On......-state resistance is routinely monitored online through the use of an innovative voltage measurement system. The packaged Silicon Carbide MOSFET is shown to exhibit a 25% increase in on-state resistance as the device ages throughout its lifetime, with the test still on-going....

  11. Calibration of full-scale accelerated pavement testing data using long-term pavement performance data

    CSIR Research Space (South Africa)

    VdM Steyn, WJ

    2012-09-01

    Full Text Available Accelerated Pavement Testing (APT) has always been conducted with the objective of improving the understanding of real pavements under real traffic and environmental conditions. While APT provides an accelerated view of some of the major structural...

  12. LOT Project long term test of buffer material at the Aespoe HRL

    International Nuclear Information System (INIS)

    Karnland, O.; Olsson, S.; Dueck, A.; Birgersson, M.; Nilsson, U.; Hernan-Haakansson, T.; Pedersen, K.; Eriksson, S.; Eriksen, T.; Eriksson, S.; Rosborg, B.; Muurinen, A.; Rousset, D.; Mosser-Ruck, R.; Cathelineau, M.; Villieras, F.; Pelletier, M.; Kaufold, S.; Dohrmann, R.; Fernandez, R.; Maeder, U.; Koroleva, M.

    2010-01-01

    Document available in extended abstract form only. Bentonite clay has been proposed as buffer material in several concepts for HLW repositories. The decaying spent fuel in the HLW canisters will increase temperature of the bentonite buffer. A number of laboratory test series, made by different research groups, have resulted in various bentonite alteration models. According to these models no significant alteration of the buffer is expected to take place at the prevailing physico-chemical conditions in the proposed Swedish KBS-3 repository, neither during, nor after water saturation. The ongoing LOT test series is focused on quantifying the mineralogical alteration in the buffer in a repository like environment at the Aespoe HRL. Further, buffer related processes concerning bacterial survival/activity, cation transport, and copper corrosion are studied. In total, the LOT test series includes seven test parcels, of which three are exposed to standard KBS-3 conditions and four test parcels are exposed to adverse conditions. Each test parcel contains a central Cu-tube surrounded by bentonite cylinder rings with a diameter of 30 cm, additional test material (Cu coupons, 60 Co tracers, bacteria etc) and instruments. Electrical heaters were place within the copper tube in order to simulate effect of decaying power from the spent fuel. The entire test parcels were released from the rock after the field exposure by overlapping boring and the bentonite material was analyzed with respect to: - physical properties (water content, density, swelling pressure, hydraulic conductivity, rheology); - mineralogical alteration in the bentonite; - distribution of added substances (e.g diffusional transport of 60 Co); - copper corrosion; - bacterial survival/activity. Two one year tests were started in 1996 and terminated in 1998. The results from tests and analyses are presented in SKB TR-00-22. The remaining four test parcels were installed during the fall 1999 plus one additional one

  13. Long term leaching of silicate systems: testing procedure, actinides behaviour and mechanism

    International Nuclear Information System (INIS)

    Louwrier, K.; Matzke, H.; Ray, I.; Thiele, H.; Scheffler, K.; Riege, U.

    1977-06-01

    High-level waste borosilicate glasses and medium-level waste cement products have been leached with various aqueous solutions at ambient temperature. The leach rates of americium and plutonium are determined as well as the behaviour of the actinides in the boundary surface glass/leachant and in the leachant itself. Methods like light-scattering photometry and differential refractometry, molecular filtration, scanning electron microscopy and α-spectrometry of the energy-loss of α-particles in thin layers have been applied. From the experimental results a general model for the leaching mechanism has been established. A critical review of leach test procedures is accomplished aiming at the improvement of common tests with respect to the extrapolation of the obtained leach test data to final disposal safety considerations. (orig.) [de

  14. Long-term water absorption tests for frost insulation materials taking into account frost attack

    Directory of Open Access Journals (Sweden)

    Toni A. Pakkala

    2014-01-01

    Full Text Available Water absorption of several different frost insulation materials was tested for four years. The test took into account both immersion and frost attack to materials. On the basis of the research the water absorption on XPS specimens is significantly minor compared to EPS specimens that were studied. The most significant result was that freezing of test specimens did not affect on water absorption of XPS specimens but had a major effect on water absorption of EPS specimens. With frozen EPS specimen the absorption continued increasing even after 48 months of immersion. Presumably the reason for such a behaviour is that the pore structure of EPS is not able to resist the tension caused by freezing water and therefore cracks are formed. Thus, more water absorbs inside the EPS through the cracks and it causes cracking deeper in the specimen which is why absorption increases after every freezing period.

  15. Long-Term Stability Testing Results Using Surrogates And Sorbents For Savannah River Site Organic And Aqueous Wastestreams - 10016

    International Nuclear Information System (INIS)

    Burns, H.

    2009-01-01

    The U.S. Department of Energy (DOE) has tasked MSE Technology Applications, Inc. (MSE) with evaluating the long-term stability of various commercially available sorbent materials to solidify two organic surrogate wastestreams (both volatile and nonvolatile), a volatile organic surrogate with a residual aqueous phase, an aqueous surrogate, and an aqueous surrogate with a residual organic phase. The Savannah River Site (SRS) Legacy and F-Canyon plutonium/uranium extraction (PUREX) process waste surrogates constituted the volatile organic surrogates, and various oils constituted the nonvolatile organic surrogates. The aqueous surrogates included a rainwater surrogate and an aqueous organic surrogate. MSE also evaluated the PUREX surrogate with a residual aqueous component with and without aqueous type sorbent materials. Solidification of the various surrogate wastestreams listed above was performed from 2004 to 2006 at the MSE Test Facility located in Butte, Montana. This paper summarizes the comparison of the initial liquid release test (LRT) values with LRT results obtained during subsequent sampling events in an attempt to understand and define the long-term stability characteristics for the solidified wastestreams.

  16. Integrity Assessment of HANARO Irradiation Capsule for Long-Term Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Yang, Tae Ho; Jun, Byung Hyuk; Kim, Myong Seop [KAERI, Daejeon (Korea, Republic of); Hong, Sang Hyun [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    The capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at around 300 .deg. C within four reactor operation cycles (about 100 days equivalent to 1.5 dpa (displacement for atom)) at HANARO. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently been required to support national R and D projects requiring much higher neutron fluence. To scope the user requirements for higher neutron irradiation fluence, several efforts using an instrumented capsule have been applied at HANARO. In this paper, the applied stresses on the capsule are estimated because the capsule was suspected to be susceptible to fatigue failure during irradiation testing. In addition, the on-going design improvements of the irradiation capsule for higher neutron irradiation fluence at HANARO are described. The applied stresses on the rod tip were analyzed using the ANSYS program. The applied stresses on the rod tip can be classified into stresses by the designed bottom spring, by the upward flowing coolant, by the capsule vibration, and by the welding residual stress. The maximal stresses due to the first three factors were estimated as 5.4 MPa, 132.9 MPa, and 161 MPa, respectively. These stresses do not exceed the known fatigue strength of stainless steels (∼300 MPa). Residual stress by welding is another possible stress and it is known to occur at up to about 300 MPa.

  17. Corrosion of metals in wood : comparing the results of a rapid test method with long-term exposure tests across six wood treatments

    Science.gov (United States)

    Samuel L. Zelinka; Donald S. Stone

    2011-01-01

    This paper compares two methods of measuring the corrosion of steel and galvanized steel in wood: a long-term exposure test in solid wood and a rapid test method where fasteners are electrochemically polarized in extracts of wood treated with six different treatments. For traditional wood preservatives, the electrochemical extract method correlates with solid wood...

  18. Long term testing of materials for tube shielding, stage 2; Laangtidsprovning av tubskyddsmaterial, etapp 2

    Energy Technology Data Exchange (ETDEWEB)

    Norling, Rikard; Hjoernhede, Anders; Mattsson, Mattias

    2012-02-15

    temperature. It varies from a few months to several years. The cost of replacing tube shielding is significant, which calls for improved materials. In a previous study [1] various materials have been tested in the WtE CFB-boiler P14 at Haendeloe in Norrkoeping, Sweden. The study showed that several materials may be cost effective candidates for replacing 253MA, but the test period was too short for safe predictions. This work includes exposures at the same position, but with extended test period up to almost 12000 h to verify the previous results. In addition results from exposures in the WtE CFB-boiler Hoegdalen P6 in Stockholm, Sweden is included. This boiler suffers in particular from severe erosion of the tube shielding requiring it to be exchanged every few months

  19. Development of mobile sensor for volcanic observation "HOMURA": Test campaigns for a long-term operation

    Science.gov (United States)

    Kaneko, K.; Iwahori, K.; Ito, K.; Sagi, H.

    2016-12-01

    Unmanned robots are useful to observe volcanic phenomena near active volcanic vents, to learn symptoms and transitions of eruptions, and to mitigate volcanic disasters. We have been trying to develop a practical UGV robot for flexible observation of active volcanic vents. We named this system "Homura". In this presentation, we report results of test campaigns of Homura for observation in a volcanic field. We have developed a prototype of Homura, which is a small robot vehicle with six wheels (75 x 43 x 31 cm and a weight of about 12 kg). It is remotely controlled with mobile phone radio waves; it can move in volcanic fields and send real time data of sensors (camera and gas sensors) equipped in the vehicle to the base station. Homura has a small solar panel (4 W). Power consumption of Homura is about 4 W in operation of sensors and less than 0.1 W in idle state, so that Homura can work outdoors for a long time by intermittent operation.We carried out two test campaigns of Homura at Iwo-yama to examine if Homura can work for a few month in natural volcanic fields (however, it had no solar panel in these campaigns). Iwo-yama is one of craters in the Kirishima volcanic field, SW Japan; the area within 1 km from the crater was an off-limit area from Oct., 2014 to May, 2015 and from Feb. to Mar., 2016 because of strong volcanic seismicity. On Feb. 19th, 2015 and Mar. 7th, 2016, we carried and put Homura at the rim of the crater. Unfortunately, mobile phone connectivity was not entirely stable around Iwo-yama. Then, we did not move Homura and only obtain real time data of the sensors. In the two campaigns, we operated Homura at our office for a few hours every day for 49 and 37 days, respectively. Although the weather was often bad (rain, fog, or cold temperature) during the campaigns, Homura perfectly worked. The results of these campaigns indicate that Homura is useful as s simple monitoring station in volcanic fields where mobile phone connection is available.

  20. Long-term test of the 22.9kV HTS power cable system in LS Cable Ltd

    International Nuclear Information System (INIS)

    Jang, Hyun Man; Lee, Chang Young; Kim, Choon Dong; Kim, Do Hyung; Park, In Son; Ji, Bong Ki; Kim, Dong Wook; Cho, Jeonwook

    2006-01-01

    Since 2001, LS cable Ltd. has been developing the design, manufacturing and evaluation technologies for high temperature superconducting (HTS) power cable system as a member of DAPAS (Dream for Advanced Power system by Applied Superconductivity technology) program in Korea. The 30 m HTS cable system that is rated at 22.9 kV and 1.2 kA giving a rated capacity of 50 MVA had been developed and tested. The cable was designed as a cold dielectric type employing Bi-2223 HTS tapes and polypropylene (PP) laminated paper as the conductor and electrical insulation, respectively. The cable is cooled with sub-cooled liquid nitrogen at temperature from 75 to 77 K. The manufacturing and the installation of the cable system were completed in 2004. Long-term performance test of the cable system has been conducted for six months to verify its electric and mechanical properties in 2005

  1. Long-term ageing tests on glazing materials for solar collectors; Langzeit-Alterungsuntersuchung an Abdeckungsmaterialien fuer thermische Sonnenkollektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ruesch, F.; Brunold, S.; Haeuselmann, T.; Frank, E.; Frei, U.

    2008-02-15

    This report made by the Swiss Institute for Solar Technology at the University of Applied Sciences in Rapperswil, Switzerland, for Swiss Federal Office of Energy (SFOE) takes a look at the results of a project that investigated the long-term behaviour of glazing materials for solar collectors. The locations tested and their associated meteorological data are presented and the tests made concerning the optical characteristics of several different types of glazing are discussed. Soiling and degradation are also looked at. An overview of the solar transmission of the various materials is presented. Details on the various materials such as glass, polymethyl metacrylate (PMMA), polycarbonate (PC), fluorised plastics, unsaturated polyester (UP), polyvinyl chloride (PVC) and polyethylene terephthalate (PET) are presented.

  2. Long term immersion test of aluminum alloy AA 6061 used for fuel cladding in MTR type reactors

    International Nuclear Information System (INIS)

    Linardi, Evelina M.; Rodriguez, Sebastian; Haddad, Roberto; Lanzani, Liliana

    2009-01-01

    In this work we present the results of long term immersion tests performed in the aluminum alloy AA 6061, used for fuel cladding in MTR type reactors. The tests were performed at open circuit potential in high purity water (ρ = 18.2 MΩ.cm) and in 10 -3 M NaCl solution. Two kinds of assemblies were studied: simple sheets and artificial crevices, immersed during 6, 12 and 18 months at room temperature. In both media and both assemblies, the aluminum hydroxide phases crystalline bayerite and bohemite were identified. It was found that a kind of localized attack named alkaline attack occurs around the iron-rich intermetallics. These particles were confirmed to control the corrosion of the AA 6061 alloy in an aerated medium. Immersion times for up to 18 months did not increase the oxide growth or the alkaline attack on the AA 6061 alloy. (author)

  3. Long-term resource variation and group size: A large-sample field test of the Resource Dispersion Hypothesis

    Directory of Open Access Journals (Sweden)

    Morecroft Michael D

    2001-07-01

    Full Text Available Abstract Background The Resource Dispersion Hypothesis (RDH proposes a mechanism for the passive formation of social groups where resources are dispersed, even in the absence of any benefits of group living per se. Despite supportive modelling, it lacks empirical testing. The RDH predicts that, rather than Territory Size (TS increasing monotonically with Group Size (GS to account for increasing metabolic needs, TS is constrained by the dispersion of resource patches, whereas GS is independently limited by their richness. We conducted multiple-year tests of these predictions using data from the long-term study of badgers Meles meles in Wytham Woods, England. The study has long failed to identify direct benefits from group living and, consequently, alternative explanations for their large group sizes have been sought. Results TS was not consistently related to resource dispersion, nor was GS consistently related to resource richness. Results differed according to data groupings and whether territories were mapped using minimum convex polygons or traditional methods. Habitats differed significantly in resource availability, but there was also evidence that food resources may be spatially aggregated within habitat types as well as between them. Conclusions This is, we believe, the largest ever test of the RDH and builds on the long-term project that initiated part of the thinking behind the hypothesis. Support for predictions were mixed and depended on year and the method used to map territory borders. We suggest that within-habitat patchiness, as well as model assumptions, should be further investigated for improved tests of the RDH in the future.

  4. Cardiopulmonary bypass and intra-aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: a PARTNER trial substudy.

    Science.gov (United States)

    Shreenivas, Satya S; Lilly, Scott M; Szeto, Wilson Y; Desai, Nimesh; Anwaruddin, Saif; Bavaria, Joseph E; Hudock, Kristin M; Thourani, Vinod H; Makkar, Raj; Pichard, Augusto; Webb, John; Dewey, Todd; Kapadia, Samir; Suri, Rakesh M; Xu, Ke; Leon, Martin B; Herrmann, Howard C

    2015-08-01

    Transcatheter aortic valve replacement (TAVR) with the balloon-expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre-emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra-aortic balloon pump (IABP) during TAVR due to pre-existing comorbid conditions or as a result of procedural complications. We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long-term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre-TAVR and those that were placed on support emergently. One-hundred sixty-three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P non-CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre-emptive use, needs reconsideration. © 2015 Wiley Periodicals, Inc.

  5. Test of a cryogenic helium pump

    International Nuclear Information System (INIS)

    Lue, J.W.; Miller, J.R.; Walstrom, P.L.; Herz, W.

    1981-01-01

    The design of a cryogenic helium pump for circulating liquid helium in a magnet and the design of a test loop for measuring the pump performance in terms of mass flow vs pump head at various pump speeds are described. A commercial cryogenic helium pump was tested successfully. Despite flaws in the demountable connections, the piston pump itself has performed satisfactorily. A helium pump of this type is suitable for the use of flowing supercritical helium through Internally Cooled Superconductor (ICS) magnets. It has pumped supercritical helium up to 7.5 atm with a pump head up to 2.8 atm. The maximum mass flow rate obtained was about 16 g/s. Performance of the pump was degraded at lower pumping speeds

  6. Long term testing and evaluation of PV modules with and without Sunarc antireflective coating of the cover glass

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Han, Jiangong

    2015-01-01

    Two Photovoltaic (PV) modules have been manufactured by Swemodule. One with Sunarc antireflective coated glass and one without glass surface treatment. The modules have been tested at DTU during 16 months under realistic outdoor conditions. Exactly the same polycrystalline cells were used...... in the modules. No cleaning of the glass has been made except for removal of bird droppings and leaves on single cells that could give a very wrong comparison. The PV modules were mounted due south at 45 degree tilt angle. They were connected to the electric grid with small 250W module inverters from Involar...... that also realized the MPP tracking to give the maximum output of each module. The electric power output was measured both on the AC and DC side and with different measurement equipment to be sure about the accuracy in improvement. The results indicate a potential long term improvement in a system from 3...

  7. OECD MCCI project long-term 2-D molten core concrete interaction test design report, Rev. 0. September 30, 2002

    International Nuclear Information System (INIS)

    Farmer, M.T.; Kilsdonk, D.J.; Lomperski, S.; Aeschliman, R.W.; Basu, S.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following two technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten core-concrete interactions under both wet and dry cavity conditions. Achievement of these two objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of the first program objective, the Small-Scale Water Ingression and Crust Strength (SSWICS) test series has been initiated to provide fundamental information on the ability of water to ingress into cracks and fissures that form in the debris during quench, thereby augmenting the otherwise conduction-limited heat transfer process. A test plan for Melt Eruption Separate Effects Tests (MESET) has also been developed to provide information on the extent of crust growth and melt eruptions as a function of gas sparging rate under well-controlled experiment conditions. In terms of the second program objective, the project Management Board (MB) has approved startup activities required to carry out

  8. Fireside corrosion and steamside oxidation of 9-12% Cr martensitic steels exposed for long term testing

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Jensen, S. A.; Rasmussen, F.

    2009-01-01

    MoV121 and HCM12 for the 12% Cr steels. The test tubes were welded in as part of the existing final superheaters in actual plants and exposure has been conducted over a ten year period (1994-2005). Compared to the older steel types, T92 and HCM12 utilise tungsten to improve their creep strength. From......To obtain long term corrosion and steam oxidation data for the 9-12%Cr ferritic steels, test tube sections have been exposed in Amager 3 and Avedore 1 coal fired power plants in Denmark (formerly run by ENERGI E2). Thus direct comparisons can be made for T91 and T92 for the 9% Cr steels and X20Cr...... Avedore I testing, T91 and T92 can be compared for exposure times up to similar to 48 000 h exposure. From Amager 3 testing, X20, HCM12 and T92 were tested; T92 has been exposed for up to 31 000 h and X20 and HCM12 have had 84 500 h exposure. Tube sections were removed for various exposure durations...

  9. Radiological assessment of long-term effects at the Semipalatinsk test site. NATO-Semipalatinsk Project 1995/96

    International Nuclear Information System (INIS)

    Hill, P.; Hille, R.; Bouisset, P.; Calmet, D.; Kluson, J.; Smagulov, S.; Sysebaev, A.

    1996-12-01

    To determine the long-term consequences of atmospheric atomic bomb tests for the population in the surroundings of the former nuclear weapons test site near Semipalatinsk, studies were performed by international cooperation between Kazakh, French, Czech and German institutions at two measuring locations (Moistik, Maisk) in Kazakhstan. Moistik is a village close to Dolon and downwind of the first atomic bomb explosion on August 29, 1947. Maisk is close to Kurchatov and not too far from ground zero. With financial support from NATO, nine experts from Europe went on a field mission to Kazakhstan in September 1995 to assess, together with Kazakh scientists, the radiological situation as far as external doses, environmental contamination and body burden of man are concerned. The results show that surface contamination from nuclear weapons tests has in the meantime decayed to a large extent. External doses largely correspond to the natural background. The remaining incorporation of longer-lived radionuclides is also slight and in 1995 merely led to an annual dose of less than 1% of the natural radiation exposure for 137 Cs and 90 Sr. The question of a dose contribution by the possible incorporation of 239 Pu remains open. Life in the villages of Maisk and Moistik does not currently involve any radiological threat to the inhabitants. However, dose reconstruction for the older inhabitants directly affected by aboveground atomic weapons tests remains difficult. (orig.)

  10. HSB 84A pumping test

    Energy Technology Data Exchange (ETDEWEB)

    Maloney, W.

    2000-03-06

    Two constant discharge, multiple well pumping tests were performed in the Congaree aquifer at the H-Area seepage basins during the weeks of April 30 through May 11. The purpose of the tests was to collect information that might determine the source of groundwater contamination in the Congaree aquifer and to estimate the hydraulic parameters of the aquifer. Transmissivity estimates from data collected in Test One ranged from 1,644 ft{sup 2}/day to 2,253 ft{sup 2}/day with an average of 2,013 ft{sup 2}/day and from 1,812 ft{sup 2}/day to 2,562 ft{sup 2}/day with an average of 2,269 ft{sup 2}/day in Test Two. Some leakage through the confining bed was apparent in the vicinity of observation well HSB 69A. This report includes the data collected, the analyses, results and interpretation of the pumping tests performed at HSB 84A. It should serve as a good baseline for future studies on the subject of contaminant migration in the Congaree aquifer on the Savannah River Site.

  11. HSB 84A pumping test

    International Nuclear Information System (INIS)

    Maloney, W.

    2000-01-01

    Two constant discharge, multiple well pumping tests were performed in the Congaree aquifer at the H-Area seepage basins during the weeks of April 30 through May 11. The purpose of the tests was to collect information that might determine the source of groundwater contamination in the Congaree aquifer and to estimate the hydraulic parameters of the aquifer. Transmissivity estimates from data collected in Test One ranged from 1,644 ft 2 /day to 2,253 ft 2 /day with an average of 2,013 ft 2 /day and from 1,812 ft 2 /day to 2,562 ft 2 /day with an average of 2,269 ft 2 /day in Test Two. Some leakage through the confining bed was apparent in the vicinity of observation well HSB 69A. This report includes the data collected, the analyses, results and interpretation of the pumping tests performed at HSB 84A. It should serve as a good baseline for future studies on the subject of contaminant migration in the Congaree aquifer on the Savannah River Site

  12. Curcuma comosa improves learning and memory function on ovariectomized rats in a long-term Morris water maze test

    Science.gov (United States)

    Su, Jian; Sripanidkulchai, Kittisak; Wyss, J. Michael; Sripanidkulchai, Bungorn

    2010-01-01

    Aim of the study Curcuma comosa extract and some purified compounds from this plant have been reported to have estrogenic-like effects, and estrogen improves learning in some animals and potentially in postmenopausal women; therefore, this study tested the hypothesis that Curcuma comosa and estrogen have similar beneficial effects on spatial learning and memory. Materials and methods Curcuma comosa hexane extract, containing 0.165 mg of (4E,6E)-1,7-diphenylhepta-4,6-dien-3-one per mg of the crude extract, was orally administered to ovariectomized Wistar rats at the doses of 250 or 500 mg/kg body weight. 17β-estradiol (10 μg/kg body weight, subcutaneously) was used as a positive control. Thirty days after the initiation of treatment, animals were tested in a Morris water maze for spatial learning and memory. They were re-tested every 30 days and a final probe trial was run on day 119. Results Compared to control rats, OVX rats displayed significant memory impairment for locating the platform in the water maze from day 67 after the surgery, onward. In contrast, OVX rats treated with either Curcuma comosa or estrogen were significantly protected from this decline in cognitive function. Further, the protection of cognitive effects by Curcuma comosa was larger at higher dose. Conclusions These results suggest that long-term treatment with Curcuma comosa has beneficial effects on learning and memory function in rats. PMID:20420894

  13. Putting it all behind: long-term psychological impact of an inconclusive DNA test result for breast cancer.

    Science.gov (United States)

    van Dijk, Sandra; Otten, Wilma; Tollenaar, Rob A E M; van Asperen, Christi J; Tibben, Aad

    2008-10-01

    An inconclusive DNA-result for breast cancer may leave women with uncertainty that cannot be relieved. We assessed the influence of beliefs women held about their inconclusive DNA-result on psychological well-being and whether women had been able to put the period of DNA testing behind them. In total, 215 women completed a baseline and a follow-up questionnaire 2.5 till 7 years after DNA test disclosure. Within the group of 147 women who received an inconclusive result (either a personal result or the result of an affected family member) multiple regression analyses were applied to investigate the relevance of women's personal beliefs. Personal beliefs and ambivalence about an inconclusive DNA-result were associated with cancer-related worry and distress (P testing behind them, even after controlling for all measures of psychological distress (P Psychological distress measures may provide an important but incomplete picture of how women make sense of an inconclusive DNA-result. These findings underscore the importance of discussing counselees' beliefs and expectations openly to enhance well-being and adaptation on the long term.

  14. Long-term durability test of acid recovery evaporators made of Ti-5% Ta alloy and zirconium

    International Nuclear Information System (INIS)

    Takeuchi, Masayuki; Koizumi, Tsutomu; Koyama, Tomozo

    2001-05-01

    Mock-ups of acid recovery evaporators which are made of Ti-5% Ta alloy and Zr were tested under inactive condition for forty thousands hours to improve a corrosion resistance of acid recovery evaporator in Tokai reprocessing plant (TRP). The mock-up unit was designed and produced referring to the specification of acid recovery evaporator in TRP and the evaporation performance of the mock-up was 1/27 of TRP. A long-term durability of both evaporators was demonstrated by results of operation data, evaporation performance and corrosion resistance. The mock-up unit did not suffer from any trouble during the running test and the operation data such as temperature, flow, concentrations of nitric acid and metal ions were fairly stable within standard condition. As for the corrosion resistance, cracks and local corrosion such as intergranular attack were not observed on both evaporators after the running test, and a corrosion of weld was not selective. The average corrosion rates at measuring points were less than 0.1 mm/yr, respectively, however, thickness of the Ti-5% Ta alloy evaporator was slightly reduced at all points of vapor phase region. In addition, from the result by test coupon, it is found that both materials have low susceptibility to stress corrosion cracking in this environment. The destructive inspection showed that the mechanical properties of both materials were not degraded during the running test. Finally, the total running time of the mock-up unit is much more than a maximum running time of acid recovery evaporator made of stainless steel in TRP (nearly 15,000 hours). On the basis of the test results, an excellent durability of Ti-5% Ta alloy and Zr evaporators under was successfully demonstrated throughout the mock-up test from an engineering perspective. (author)

  15. Enhance pump reliability through improved inservice testing

    International Nuclear Information System (INIS)

    Healy, J.J.

    1990-01-01

    EPRI has undertaken a study to assess the effectiveness of existing testing programs to accurately monitor and predict performance changes before either pump performance degrades or an actual failure occurs. Anticipated changes in inservice testing techniques are directed towards enhancing the validity of test data, ensuring its repeatability, and avoiding deterioration of the pump assembly. There is a new-found interest in test programs of all types that has occurred, in part, because of an increase in reported pump degradation and pump failure. Inservice testing of pumps, which has long been a basis for assuring operability, has apparently produced an opposite effect; namely, the appearance of a reduction in reliability

  16. Analytical electron microscopy examination of solid reaction products in long-term test of SRL 200 waste glasses

    International Nuclear Information System (INIS)

    Buck, E.C.; Fortner, J.A.; Bates, J.K.; Feng, X.; Dietz, N.L.; Bradley, C.R.; Tani, B.S.

    1993-01-01

    Alteration phases, found on the leached surfaces and present as colloids in the leachates of 200-based frit (fully active and simulated) nuclear waste glass, reacted under static test conditions, at a surface area to leachate volume ratio of 20,000 m -1 for 15 days to 728 days, have been examined by analytical electron microscopy. The compositions of the secondary phases were determined using x-ray energy dispersive spectroscopy and electron energy loss spectroscopy, and structural analysis was accomplished by electron diffraction. Long-term samples of simulated glass, which had undergone an acceleration of reaction after 182 days, possessed a number of silicate secondary phases, including; smectite (iron silicate and potassium iron alumina-silicate, weeksite (uranium silicate), zeolite (calcium potassium alumino-silicate), tobermorite (calcium silicate), and a pure silica phase. However, uranium silicates and smectite have also been observed in tests, which have not undergone the acceleration of reaction, in both the leachate and leached layer, suggesting that these phases are not responsible for the acceleration of reaction

  17. Durability and efficiency tests for direct methanol fuel cell's long-term performance assessment

    International Nuclear Information System (INIS)

    Yeh, Pulin; Chang, Chu Hsiang; Shih, Naichien; Yeh, Naichia

    2016-01-01

    This research assessed the long-term performance of direct methanol fuel cells. The experiment was performed at room temperature using 0.51 mol/L ∼0.651 mol/L methanol with a fuel consumption rate of 0.8 ± 0.1 cc/Wh at stack temperature of 60 °C–70 °C. DuPont Nafion115 proton exchange membrane was used as the base material of MEA (membrane electrode assembly), which is then examined via a series of processes that include I−V curve test, humidity cycle test, load cycle test, and hydrogen penetration test. The study employs membrane modification and cell structure adjustment approaches to reduce the methanol crossover in the cathode and identify the cell performance effect of the carbon paper gas diffusion layer. The test results indicated an efficiency of 25% can be achieved with a three-piece MEA assembly. According to the durability test, the stack power-generation efficiency has maintained at 15%–25% level. With such efficiency, the stack voltage output has been able to stay above 7.8-V for over 5000 h. This result is in line with industry standard. - Highlights: • Assess DMFC performance under non-optimal conditions for production readiness. • Output of 26-cell DMFC stack stays beyond 7.8v after 5000 operation hours. • Power-generation efficiency of 26-cell DMFC stack maintains between 15%–20%.

  18. Long term complications of diabetes

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000327.htm Long-term complications of diabetes To use the sharing features on this page, ... other tests. All these may help you keep complications of diabetes away. You will need to check your blood ...

  19. The role of long-term memory in digit-symbol test performance in young and older adults.

    Science.gov (United States)

    Stephens, R; Kaufman, A

    2009-03-01

    The psychological functions assessed by substitution tests, and the age-related performance decline, are not well understood. Here several aspects of long-term memory were manipulated across younger and older adults. A 45-page Digit-Symbol test was employed. Each page contained a 9-item digit symbol code-table and 9 response items. There were 9 study conditions with each condition deployed across 5 pages, or trials, of the test. The conditions were formed by crossing two within-subjects factors, each with 3 levels. The first factor, Digit Order, pertained to having the code table digits in numerical order vs. a pseudo-random order fixed across trials vs. a pseudo-random order that varied across trials. The second factor, Symbol Pairing, pertained to having a fixed digit-symbol pairing across trials vs. having a varying digit-symbol pairing across trials vs. having a novel set of 9 symbols introduced on each of the 5 trials. Including the additional factor, Age, resulted in a 2 x 3 x 3 mixed randomised block design. The older group was slowed, F(1, 22) = 17.267, p Symbol-Order interaction indicated that use of novel symbols disadvantaged only the older participants, F(1, 44) = 6.577, p = .014. While there was no evidence that incidental paired-associate learning or spatial memory affect digit-symbol performance, symbol familiarity may be important to digit symbol test completion in older adults. The benefit of ordinally arranged digits in the coding table highlights a fundamental process difference between Digit-Symbol and Symbol-Digit test formats.

  20. Testing the generalized complementary relationship of evaporation with continental-scale long-term water-balance data

    Science.gov (United States)

    Szilagyi, Jozsef; Crago, Richard; Qualls, Russell J.

    2016-09-01

    The original and revised versions of the generalized complementary relationship (GCR) of evaporation (ET) were tested with six-digit Hydrologic Unit Code (HUC6) level long-term (1981-2010) water-balance data (sample size of 334). The two versions of the GCR were calibrated with Parameter-Elevation Regressions on Independent Slopes Model (PRISM) mean annual precipitation (P) data and validated against water-balance ET (ETwb) as the difference of mean annual HUC6-averaged P and United States Geological Survey HUC6 runoff (Q) rates. The original GCR overestimates P in about 18% of the PRISM grid points covering the contiguous United States in contrast with 12% of the revised version. With HUC6-averaged data the original version has a bias of -25 mm yr-1 vs the revised version's -17 mm yr-1, and it tends to more significantly underestimate ETwb at high values than the revised one (slope of the best fit line is 0.78 vs 0.91). At the same time it slightly outperforms the revised version in terms of the linear correlation coefficient (0.94 vs 0.93) and the root-mean-square error (90 vs 92 mm yr-1).

  1. Detection of Acute and Long-Term Effects of Concussion: Dual-Task Gait Balance Control Versus Computerized Neurocognitive Test.

    Science.gov (United States)

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2018-02-16

    To examine the acute (within 72h of injury) and long-term (2mo postinjury) independent associations between objective dual-task gait balance and neurocognitive measurements among adolescents and young adults with a concussion and matched controls. Longitudinal case-control. Motion analysis laboratory. A total of 95 participants completed the study: 51 who sustained a concussion (mean age, 17.5±3.3y; 71% men) and 44 controls (mean age, 17.7±2.9y; 72% men). Participants who sustained a concussion underwent a dual-task gait analysis and computerized neurocognitive testing within 72 hours of injury and again 2 months later. Uninjured controls also completed the same test protocol in similar time increments. Not applicable. We compared dual-task gait balance control and computerized neurocognitive test performance between groups using independent samples t tests. Multivariable binary logistic regression models were then constructed for each testing time to determine the association between group membership (concussion vs control), dual-task gait balance control, and neurocognitive function. Medial-lateral center-of-mass displacement during dual-task gait was independently associated with group membership at the initial test (adjusted odds ratio [aOR], 2.432; 95% confidence interval [CI], 1.269-4.661) and 2-month follow-up test (aOR, 1.817; 95% CI, 1.014-3.256) tests. Visual memory composite scores were significantly associated with group membership at the initial hour postinjury time point (aOR, .953; 95% CI, .833-.998). However, the combination of computerized neurocognitive test variables did not predict dual-task gait balance control for participants with concussion, and no single neurocognitive variable was associated with dual-task gait balance control at either testing time. Dual-task assessments concurrently evaluating gait and cognitive performance may allow for the detection of persistent deficits beyond those detected by computerized neurocognitive deficits

  2. Simulation of ultra-long term behavior in HLW near-field by centrifugal model test. Part 1. Development of centrifugal equipment and centrifuge model test method

    International Nuclear Information System (INIS)

    Nishimoto, Soshi; Okada, Tetsuji; Sawada, Masataka

    2011-01-01

    The objective of this paper is to develop a centrifugal equipment which can continuously be run for a long time and a model test method in order to evaluate a long term behavior which is a coupled thermo-hydro-mechanical processes in the high level wastes geological disposal repository and the neighborhood (called 'near-field'). The centrifugal equipment of CRIEPI, 'CENTURY5000-THM', developed in the present study is able to run continuously up to six months. Therefore, a long term behavior in the near-field can be simulated in a short term, for instance, the behavior for 5000 equivalent years can be simulated in six months by centrifugalizing 100 G using a 1/100 size model. We carried out a test using a nylon specimen in a centrifugal force field of 30 G and confirmed the operations of CENTURY5000-THM, control and measurement for 11 days. As the results, it was able to control the stress in the pressure vessel and measure the values of strain, temperature and pressure. And, as a result of scanning the small model of near-field including the metal overpack, bentonite buffer and rock by a medical X-rays CT scanner, the internal structure of the model was able to be evaluated when the metal artifact was reduced. From these results, the evaluation for a long term behavior of a disposal repository by the method of centrifugal model test became possible. (author)

  3. Analysis on the Long Term Effect of Trial Test Road Constructed on Batu Pahat Soft Clay (BPSC) at Recess UTHM

    Science.gov (United States)

    Idrus, M. M. M.; Edayu, A. E.; Adnan, Z.; Ismail, B.

    2016-07-01

    The reinforcement used in soil for construction of roads on the soft clay is very important as it will determine the level of service of the road after it was built. Damage or defects on the road surface to be an indicator of the level of the road has dropped and shows the deformation of the road. For this research, an analysis has carried out on the long-term effect of trial test road constructed on Batu Pahat Soft Clay (BPSC) at RECESS UTHM. Through this research, the reinforcement using Rawell Geosynthetic Clay Liner (RGCL) was the best with the stability is 14964 N, a low flow is 2.69mm, stiffness modulus is 1766 MPa, the peak load is 739.4 N and a lower horizontal deformation which is 1.71 µm compared Woven Geotextile section and section without geotextile [1] [9]. In terms of deformation can be seen clearly from physical observations that section without geotextile suffered significant damage than others. Settlement of road can also be analyzed by a longitudinal section that plotted based on the result of leveling work. After that, settlements are more visible way on the right side of the road trial. Through lab tests conducted, it indicate that the coring samples obtained from sites of each section meets the specifications set by the Jabatan Kerja Raya (JKR) in terms of stability, flow and stiffness [1]. Through this study, a trial road built on soft soil can be used as a test site because of the uniqueness of these roads which has three different types of reinforcements.

  4. Mitigation of tank 241-SY-101 by pump mixing: Results of full-scale testing

    International Nuclear Information System (INIS)

    Stewart, C.W.; Hudson, J.D.; Friley, J.R.; Panisko, F.E.; Antoniak, Z.I.; Irwin, J.J.; Fadeff, J.G.; Efferding, L.F.; Michener, T.E.; Kirch, N.W.

    1994-06-01

    The Full-Scale Mixer Pump Test Program was performed in Hanford Tank 241-SY-101 from February 4 to April 13, 1994, to confirm the long-term operational strategy for flammable gas mitigation and to demonstrate that mixing can control the gas release and waste level. Since its installation on July 3, 1993, the current pump, operating only a few hours per week, has proved capable of mixing the waste sufficiently to release gas continuously instead of in large episodic events. The results of Full-Scale Testing demonstrated that the pump can control gas release and waste level for long-term mitigation, and the four test sequences formed the basis for the long-term operating schedule. The last test sequence, jet penetration tests, showed that the current pump jet creates flow near the tank wall and that it can excavate portions of the bottom sludge layer if run at maximum power. Pump mixing has altered the open-quote normal close-quote configuration of the waste; most of the original nonconvective sludge has been mixed with the supernatant liquid into a mobile convective slurry that has since been maintained by gentle pump operation and does not readily return to sludge

  5. A link of full-scale accelerated pavement testing to long-term pavement performance study in the Western Cape Province of South Africa

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph K

    2016-09-01

    Full Text Available of Accelerated Pavement Testing in Pavement Sustainability A Link of Full-Scale Accelerated Pavement Testing to Long-Term Pavement Performance Study in the Western Cape Province of South Africa J. K. Anochie-Boateng W. JvdM Steyn C. Fisher L. Truter...

  6. Hearing Loss and Cognitive-Communication Test Performance of Long-Term Care Residents With Dementia: Effects of Amplification

    Science.gov (United States)

    Hopper, Tammy; Slaughter, Susan E.; Hodgetts, Bill; Ostevik, Amberley; Ickert, Carla

    2016-01-01

    Purpose: The study aims were (a) to explore the relationship between hearing loss and cognitive-communication performance of individuals with dementia, and (b) to determine if hearing loss is accurately identified by long-term care (LTC) staff. The research questions were (a) What is the effect of amplification on cognitive-communication test…

  7. Long-term morphine delivery via slow release morphine pellets or osmotic pumps: Plasma concentration, analgesia, and naloxone-precipitated withdrawal.

    Science.gov (United States)

    McLane, Virginia D; Bergquist, Ivy; Cormier, James; Barlow, Deborah J; Houseknecht, Karen L; Bilsky, Edward J; Cao, Ling

    2017-09-15

    Slow-release morphine sulfate pellets and osmotic pumps are common routes of chronic morphine delivery in mouse models, but direct comparisons of these drug delivery systems are lacking. In this study, we assessed the efficacy of slow-release pellets versus osmotic pumps in delivering morphine to adult mice. Male C57BL/6NCr mice (8weeksold) were implanted subcutaneously with slow-release pellets (25mg morphine sulfate) or osmotic pumps (64mg/mL, 1.0μL/h). Plasma morphine concentrations were quantified via LC-MS/MS, analgesic efficacy was determined by tail flick assay, and dependence was assessed with naloxone-precipitated withdrawal behaviors (jumping) and physiological effects (excretion, weight loss). Morphine pellets delivered significantly higher plasma drug concentrations compared to osmotic pumps, which were limited by the solubility of the morphine sulfate and pump volume/flow rate. Within 96h post-implantation, plasma morphine concentrations were indistinguishable in pellet vs. pump-treated samples. While osmotic pump did not have an antinociceptive effect in the tail flick assay, pumps and pellets induced comparable dependence symptoms (naloxone-precipitated jumping behavior) from 24-72h post-implantation. In this study, we compared slow-release morphine pellets to osmotic minipumps for morphine delivery in mice. We found that osmotic pumps and subcutaneous morphine sulfate pellets yielded significantly different pharmacokinetics over a 7-day period, and as a result significantly different antinociceptive efficacy. Nonetheless, both delivery methods induced dependence as measured by naloxone-precipitated withdrawal. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Long-term retention of a divided attention psycho-motor test combining choice reaction test and postural balance test: A preliminary study.

    Science.gov (United States)

    Rossi, R; Pascolo, P B

    2015-09-01

    Driving in degraded psychophysical conditions, such as under the influence of alcohol or drugs but also in a state of fatigue or drowsiness, is a growing problem. The current roadside tests used for detecting drugs from drivers suffer various limitations, while impairment is subjective and does not necessarily correlate with drug metabolite concentration found in body fluids. This work is a validation step towards the study of feasibility of a novel test conceived to assess psychophysical conditions of individuals performing at-risk activities. Motor gestures, long-term retention and learning phase related to the protocol are analysed in unimpaired subjects. The protocol is a divided attention test, which combines a critical tracking test achieved with postural movements and a visual choice reaction test. Ten healthy subjects participated in a first set of trials and in a second set after about six months. Each session required the carrying out of the test for ten times in order to investigate learning effect and performance over repetitions. In the first set the subjects showed a learning trend up to the third trial, whilst in the second set of trials they showed motor retention. Nevertheless, the overall performance did not significantly improve. Gestures are probably retained due to the type of tasks and the way in which the instructions are conveyed to the subjects. Moreover, motor retention after a short training suggests that the protocol is easy to learn and understand. Implications for roadside test usage and comparison with current tests are also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Long-Term Performance of Transuranic Waste Inadvertently Disposed in a Shallow Land Burial Trench at the Nevada Test Site

    International Nuclear Information System (INIS)

    Shott, Gregory J.; Yucel, Vefa

    2009-01-01

    In 1986, 21 m3 of transuranic (TRU) waste was inadvertently disposed in a shallow land burial trench at the Area 5 Radioactive Waste Management Site on the Nevada Test Site. U.S. Department of Energy (DOE) TRU waste must be disposed in accordance with Title 40, Code of Federal Regulations (CFR), Part 191, Environmental Radiation Protection Standard for Management and Disposal of Spent Nuclear Fuel, High-Level, and Transuranic Radioactive Wastes. The Waste Isolation Pilot Plant is the only facility meeting these requirements. The National Research Council, however, has found that exhumation of buried TRU waste for disposal in a deep geologic repository may not be warranted when the effort, exposures, and expense of retrieval are not commensurate with the risk reduction achieved. The long-term risks of leaving the TRU waste in-place are evaluated in two probabilistic performance assessments. A composite analysis, assessing the dose from all disposed waste and interacting sources of residual contamination, estimates an annual total effective dose equivalent (TEDE) of 0.01 mSv, or 3 percent of the dose constraint. A 40 CFR 191 performance assessment also indicates there is reasonable assurance of meeting all requirements. The 40 CFR 191.15 annual mean TEDE for a member of the public is estimated to reach a maximum of 0.055 mSv at 10,000 years, or approximately 37 percent of the 0.15 mSv individual protection requirement. In both assessments greater than 99 percent of the dose is from co-disposed low-level waste. The simulated probability of the 40 CFR 191.13 cumulative release exceeding 1 and 10 times the release limit is estimated to be 0.0093 and less than 0.0001, respectively. Site characterization data and hydrologic process modeling support a conclusion of no groundwater pathway within 10,000 years. Monte Carlo uncertainty analysis indicates that there is reasonable assurance of meeting all regulatory requirements. Sensitivity analysis indicates that the results

  10. Testing seasonal and long-term controls of streamwater DOC using empirical and process-based models.

    Science.gov (United States)

    Futter, Martyn N; de Wit, Heleen A

    2008-12-15

    Concentrations of dissolved organic carbon (DOC) in surface waters are increasing across Europe and parts of North America. Several mechanisms have been proposed to explain these increases including reductions in acid deposition, change in frequency of winter storms and changes in temperature and precipitation patterns. We used two modelling approaches to identify the mechanisms responsible for changing surface water DOC concentrations. Empirical regression analysis and INCA-C, a process-based model of stream-water DOC, were used to simulate long-term (1986--2003) patterns in stream water DOC concentrations in a small boreal stream. Both modelling approaches successfully simulated seasonal and inter-annual patterns in DOC concentration. In both models, seasonal patterns of DOC concentration were controlled by hydrology and inter-annual patterns were explained by climatic variation. There was a non-linear relationship between warmer summer temperatures and INCA-C predicted DOC. Only the empirical model was able to satisfactorily simulate the observed long-term increase in DOC. The observed long-term trends in DOC are likely to be driven by in-soil processes controlled by SO4(2-) and Cl(-) deposition, and to a lesser extent by temperature-controlled processes. Given the projected changes in climate and deposition, future modelling and experimental research should focus on the possible effects of soil temperature and moisture on organic carbon production, sorption and desorption rates, and chemical controls on organic matter solubility.

  11. Long-term collections

    CERN Multimedia

    Collectes à long terme

    2007-01-01

    The Committee of the Long Term Collections (CLT) asks for your attention for the following message from a young Peruvian scientist, following the earthquake which devastated part of her country a month ago.

  12. French nuclear plant safeguard pump qualification testing: EPEC test loop

    International Nuclear Information System (INIS)

    Guesnon, H.

    1985-01-01

    This paper reviews the specifications to which nuclear power plant safeguard pumps must be qualified, and surveys the qualification methods and program used in France to verify operability of the pump assembly and major pump components. The EPEC test loop is described along with loop capabilities and acheivements up to now. This paper shows, through an example, the Medium Pressure Safety Injection Pump designed for service in 1300 MW nuclear power plants, and the interesting possibilities offered by qualification testing

  13. Should patients prescribed long-term low-dose aspirin receive proton pump inhibitors? A systematic review and meta-analysis

    NARCIS (Netherlands)

    Tran-Duy, A.; Vanmolkot, F. H.; Joore, M. A.; Hoes, A. W.; Stehouwer, C. D. A.

    2015-01-01

    Background: Several clinical guidelines recommend the use of proton pump inhibitors (PPIs) in patients taking low-dose aspirin but report no or limited supporting data. We conducted a systematic review and meta-analysis to examine the effects of co-administration of PPIs in patients taking low-dose

  14. Long-term memory for verbal and visual information in Down syndrome and Williams syndrome: performance on the Doors and People test.

    Science.gov (United States)

    Jarrold, Christopher; Baddeley, Alan D; Phillips, Caroline

    2007-02-01

    Previous studies have suggested that Williams syndrome and Down syndrome may be associated with specific short-term memory deficits. Individuals with Williams syndrome perform relatively poorly on tests of visuo-spatial short-term memory and individuals with Down syndrome show a relative deficit on verbal short-term memory tasks. However, these patterns of impairments may reflect the impact of generally impaired visuo-spatial processing skills in Williams syndrome, and verbal abilities in Down syndrome. The current study explored this possibility by assessing long-term memory among 15 individuals with Williams syndrome and 20 individuals with Down syndrome using the Doors and People test, a battery which assesses recall and recognition of verbal and visual information. Individuals' performance was standardised for age and level of intellectual ability with reference to that shown by a sample of 110 typically developing children. The results showed that individuals with Down syndrome have no differential deficits in long-term memory for verbal information, implying that verbal short-term memory deficits in this population are relatively selective. Instead both individuals with Down syndrome and with Williams syndrome showed some evidence of relatively poor performance on tests of long-term memory for visual information. It is therefore possible that visuo-spatial short-term memory deficits that have previously been demonstrated in Williams syndrome may be secondary to more general problems in visuo-spatial processing in this population.

  15. Long-Term Collections

    CERN Multimedia

    Comité des collectes à long terme

    2011-01-01

    It is the time of the year when our fireman colleagues go around the laboratory for their traditional calendars sale. A part of the money of the sales will be donated in favour of the long-term collections. We hope that you will welcome them warmly.

  16. Evaluation of long-term behavior of concretes in high level waste repositories. An accelerated leaching test

    Directory of Open Access Journals (Sweden)

    Hidalgo, A.

    2004-04-01

    Full Text Available The present work describes an accelerated leaching method that with a rapid process allows to develop and evaluate cements for use in a nuclear disposal, and the understanding of the long term effects. The method has been developed to study the stability of cementitious materials in contact with bentonite, to be used in high level radioactivity waste repositories. Nitric acid has been selected to simulate in an accelerated way the pH decreasing produced when concrete is in contact with groundwaters.

    El presente trabajo describe un ensayo acelerado de lixiviación, que mediante un proceso rápido, permite desarrollar y evaluar cementos para su uso en instalaciones nucleares, y la comprensión de su comportamiento a largo plazo. El método se ha desarrollado para estudiar la estabilidad de materiales de base cemento, en contacto con bentonita, que serán utilizados en almacenamientos de resíduos radiactivos de alta actividad. Como agente lixiviante se seleccionó el ácido nítrico, con objeto de simular de forma acelerada, la disminución del pH que se produce cuando el hormigón entra en contacto con aguas subterráneas.

  17. Study Design to Test the Hypothesis That Long-Term Space Travel Harms the Human and Animal Immune Systems

    Science.gov (United States)

    Shearer, William T.; Lugg, Desmond J.; Ochs, H. D.; Pierson, Duane L.; Reuben, James M.; Rosenblatt, Howard M.; Sams, Clarence; Smith, C. Wayne; Smith, E. Obrian; Smolen, James E.

    1999-01-01

    The potential threat of immunosuppression and abnormal inflammatory responses in long-term space travel, leading to unusual predilection for opportunistic infections, malignancy, and death, is of ma or concern to the National Aeronautics and Space Administration (NASA) Program. This application has been devised to seek answers to questions of altered immunity in space travel raised by previous investigations spanning 30-plus years. We propose to do this with the help of knowledge gained by the discovery of the molecular basis of many primary and secondary immunodeficiency diseases and by application of molecular and genetic technology not previously available. Two areas of immunity that previously received little attention in space travel research will be emphasized: specific antibody responses and non-specific inflammation and adhesion. Both of these areas of research will not only add to the growing body of information on the potential effects of space travel on the immune system, but be able to delineate any functional alterations in systems important for antigen presentation, specific immune memory, and cell:cell and cell:endothelium interactions. By more precisely defining molecular dysfunction of components of the immune system, it is hoped that targeted methods of prevention of immune damage in space could be devised.

  18. Body size and geographic range do not explain long term variation in fish populations: a Bayesian phylogenetic approach to testing assembly processes in stream fish assemblages.

    Directory of Open Access Journals (Sweden)

    Stephen J Jacquemin

    Full Text Available We combine evolutionary biology and community ecology to test whether two species traits, body size and geographic range, explain long term variation in local scale freshwater stream fish assemblages. Body size and geographic range are expected to influence several aspects of fish ecology, via relationships with niche breadth, dispersal, and abundance. These traits are expected to scale inversely with niche breadth or current abundance, and to scale directly with dispersal potential. However, their utility to explain long term temporal patterns in local scale abundance is not known. Comparative methods employing an existing molecular phylogeny were used to incorporate evolutionary relatedness in a test for covariation of body size and geographic range with long term (1983 - 2010 local scale population variation of fishes in West Fork White River (Indiana, USA. The Bayesian model incorporating phylogenetic uncertainty and correlated predictors indicated that neither body size nor geographic range explained significant variation in population fluctuations over a 28 year period. Phylogenetic signal data indicated that body size and geographic range were less similar among taxa than expected if trait evolution followed a purely random walk. We interpret this as evidence that local scale population variation may be influenced less by species-level traits such as body size or geographic range, and instead may be influenced more strongly by a taxon's local scale habitat and biotic assemblages.

  19. Evaluation of precipitates used in strainer head loss testing: Part III. Long-term aluminum hydroxide precipitation tests in borated water

    International Nuclear Information System (INIS)

    Bahn, Chi Bum; Kasza, Ken E.; Shack, William J.; Natesan, Ken; Klein, Paul

    2011-01-01

    Research highlights: → Aluminum hydroxide precipitation boundary is similar to that for amorphous phase. → Various precipitation tests are combined into one map in temperature-'pH + p[Al] T '. → Flocculation tendency of precipitates depend on pH and total Al concentration. → DLVO theory explains qualitatively the dependency of flocculation tendency on pH. - Abstract: Long-term aluminum (Al) hydroxide precipitation tests were conducted in slightly alkaline solutions containing 2500 ppm boron. The solution temperature was cycled to obtain a temperature history more representative of emergency core cooling system temperatures after a loss-of-coolant accident. The observed Al precipitation boundary was close to predicted results for amorphous precipitates, which are higher than the solubility expected for crystalline forms. Bench-scale and loop head loss test results under various conditions were successfully combined into single map in a temperature - 'pH + p[Al] T ' domain, which yielded two bounding lines for Al hydroxide solubility in borated alkaline water that depend on whether or not loop head loss tests with Al alloy coupons are included. Precipitates were observed to form either as fine, cloudy suspensions, which showed very little tendency to settle, or as flocculated precipitates. The flocculation tendency of the precipitates can be qualitatively explained by a colloid stability theory or a phase diagram for protein solutions.

  20. Synthesis of published and unpublished corrosion data from long term tests of fasteners embedded in wood : calculation of corrosion rates and the effect of corrosion on lateral joint strength

    Science.gov (United States)

    Samuel L. Zelinka; Douglas R. Rammer

    2011-01-01

    In the past 5 years, several accelerated test methods have been developed to measure the corrosion of metals in contact with wood. It is desirable to contrast these accelerated results against those of long term exposure tests. While there have been several published long-term exposure tests performed on metals in treated wood, the data from these studies could not be...

  1. Main coolant pump testing at Ontario Hydro

    International Nuclear Information System (INIS)

    Hartlen, R.

    1991-01-01

    This article describes Ontario Hydro Research Division's experience with a computerized data acquisition and analysis system for monitoring mechanical vibration in reactor coolant pumps. The topics covered include bench-marking of the computer system and the coolant pumps, signatures of normal and malfunctioning pumps, analysis of data collected by the monitoring system, simulation of faults, and concerns that have been expressed about data interpretation, sensor types and locations, alarm/shutdown limits and confirmation of nondestructive examination testing. This presentation consists of overheads only

  2. DNA typing for personal identification of urine after long-term preservation for testing in doping control.

    Science.gov (United States)

    Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto

    2017-08-01

    When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Comparing long-term results of PASAT and SDMT scores in relation to neuropsychological testing in multiple sclerosis

    NARCIS (Netherlands)

    Sonder, J.M.; Burggraaff, J.; Knol, D.L.; Polman, C.H.; Uitdehaag, B.M.J.

    2014-01-01

    Background and objectives: The Symbol Digit Modalities Test (SDMT) shows advantages over the Paced Auditory Serial Addition Test (PASAT) as a cognitive test in patients with multiple sclerosis (MS). To determine which of these tests is most valid and reliable over time as an indicator of the

  4. The Role of Test Expectancy in the Build-Up of Proactive Interference in Long-Term Memory

    Science.gov (United States)

    Weinstein, Yana; Gilmore, Adrian W.; Szpunar, Karl K.; McDermott, Kathleen B.

    2014-01-01

    We examined the hypothesis that interpolated testing in a multiple list paradigm protects against proactive interference by sustaining test expectancy during encoding. In both experiments, recall on the last of 5 word lists was compared between 4 conditions: a tested group who had taken tests on all previous lists, an untested group who had not…

  5. Safety of long-term PPI therapy

    DEFF Research Database (Denmark)

    Reimer, Christina

    2013-01-01

    Proton pump inhibitors have become the mainstay of medical treatment of acid-related disorders. Long-term use is becoming increasingly common, in some cases without a proper indication. A large number of mainly observational studies on a very wide range of possible associations have been publishe...... to a careful evaluation of the indication for PPI treatment....

  6. Mitigation of Tank 241-SY-101 by pump mixing: Results of testing phases A and B

    Energy Technology Data Exchange (ETDEWEB)

    Allemann, R.T.; Antoniak, Z.I.; Chvala, W.D.; Friley, J.R.; Gregory, W.B.; Hudson, J.D.; Michener, T.E.; Panisko, F.E.; Stewart, C.W.; Wise, B.M. [Pacific Northwest Lab., Richland, WA (United States); Efferding, L.E.; Fadeff, J.G.; Irwin, J.J.; Kirch, N.W. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-03-01

    A spare mixing pump from the Hanford Grout Program was installed in Hanford double-shell waste Tank 241-SY-101 on July 3, 1993, after being modified to take advantage of waste stratification. It was anticipated that pump mixing would prevent large episodic flammable gas releases that had been occurring about every 100-150 days. A cautious initial test plan, called Phase A, was run to find how the pump and tank would behave in response to very brief and gentle pump operation. No large gas releases were triggered, and the pump performed well except for two incidents of nozzle plugging. On October 21, 1993, the next test series, Phase B, began, and the pump was applied more aggressively to mix the tank contents and mitigate uncontrolled gas releases. Orienting the pump in new directions released large volumes of gas and reduced the waste level to a near-record low. Results of the entire period from pump installation to the end of Phase B on December 17, 1993, are presented in detail in this document. Though long-term effects require further evaluation, we conclude from these data that the jet mixer pump is an effective means of controlling flammable gas release and that it has met the success criteria for mitigation in this tank.

  7. Test Methodology Development for Experimental Structural Assessment of ASC Planar Spring Material for Long-Term Durability

    Science.gov (United States)

    Yun, Gunjin; Abdullah, A. B. M.; Binienda, Wieslaw; Krause, David L.; Kalluri, Sreeramesh

    2014-01-01

    A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses

  8. Long-Term Collections

    CERN Multimedia

    Staff Association

    2016-01-01

    45 years helping in developing countries! CERN personnel have been helping the least fortunate people on the planet since 1971. How? With the Long-Term Collections! Dear Colleagues, The Staff Association’s Long-Term Collections (LTC) Committee is delighted to share this important milestone in the life of our Laboratory with you. Indeed, whilst the name of CERN is known worldwide for scientific discoveries, it also shines in the many humanitarian projects which have been supported by the LTC since 1971. Several schools and clinics, far and wide, carry its logo... Over the past 45 years, 74 projects have been supported (9 of which are still ongoing). This all came from a group of colleagues who wanted to share a little of what life offered them here at CERN, in this haven of mutual understanding, peace and security, with those who were less fortunate elsewhere. Thus, the LTC were born... Since then, we have worked as a team to maintain the dream of these visionaries, with the help of regular donat...

  9. Long-Term Collection

    CERN Multimedia

    Staff Association

    2016-01-01

    Dear Colleagues, As previously announced in Echo (No. 254), your delegates took action to draw attention to the projects of the Long-Term Collections (LTC), the humanitarian body of the CERN Staff Association. On Tuesday, 11 October, at noon, small Z-Cards were widely distributed at the entrances of CERN restaurants and we thank you all for your interest. We hope to have achieved an important part of our goal, which was to inform you, convince you and find new supporters among you. We will find out in the next few days! An exhibition of the LTC was also set up in the Main Building for the entire week. The Staff Association wants to celebrate the occasion of the Long-Term Collection’s 45th anniversary at CERN because, ever since 1971, CERN personnel have showed great support in helping the least fortunate people on the planet in a variety of ways according to their needs. On a regular basis, joint fundraising appeals are made with the Directorate to help the victims of natural disasters around th...

  10. Collectes à long terme

    CERN Multimedia

    Collectes à long terme

    2014-01-01

    En cette fin d’année 2014 qui approche à grands pas, le Comité des Collectes à Long Terme remercie chaleureusement ses fidèles donatrices et donateurs réguliers pour leurs contributions à nos actions en faveur des plus démunis de notre planète. C’est très important, pour notre Comité, de pouvoir compter sur l’appui assidu que vous nous apportez. Depuis plus de 40 ans maintenant, le modèle des CLT est basé principalement sur des actions à long terme (soit une aide pendant 4-5 ans par projet, mais plus parfois selon les circonstances), et sa planification demande une grande régularité de ses soutiens financiers. Grand MERCI à vous ! D’autres dons nous parviennent au cours de l’année, et ils sont aussi les bienvenus. En particulier, nous tenons à remercier...

  11. Long term evaluation and identification of the proper testing program for ASTM Class C fly ash stabilized soils : technical summary.

    Science.gov (United States)

    1993-07-01

    The objectives of this research were to further evaluate the characteristics of locally produced fly ash and to develop test procedures which would expedite the evaluation of fly ash stabilized soils. Because cement and lime stabilization techniques ...

  12. Long-term maintenance of immediate or delayed extinction is determined by the extinction-test interval

    OpenAIRE

    Johnson, Justin S.; Escobar, Martha; Kimble, Whitney L.

    2010-01-01

    Short acquisition-extinction intervals (immediate extinction) can lead to either more or less spontaneous recovery than long acquisition-extinction intervals (delayed extinction). Using rat subjects, we observed less spontaneous recovery following immediate than delayed extinction (Experiment 1). However, this was the case only if a relatively long extinction-test interval was used; a relatively short extinction-test interval yielded the opposite result (Experiment 2). Previous data appear co...

  13. The effects of prolonged administration of norepinephrine reuptake inhibitors on long-term potentiation in dentate gyrus, and on tests of spatial and object recognition memory in rats.

    Science.gov (United States)

    Walling, Susan G; Milway, J Stephen; Ingram, Matthew; Lau, Catherine; Morrison, Gillian; Martin, Gerard M

    2016-02-01

    Phasic norepinephrine (NE) release events are involved in arousal, novelty detection and in plasticity processes underlying learning and memory in mammalian systems. Although the effects of phasic NE release events on plasticity and memory are prevalently documented, it is less understood what effects chronic NE reuptake inhibition and sustained increases in noradrenergic tone, might have on plasticity and cognitive processes in rodent models of learning and memory. This study investigates the effects of chronic NE reuptake inhibition on hippocampal plasticity and memory in rats. Rats were administered NE reuptake inhibitors (NRIs) desipramine (DMI; 0, 3, or 7.5mg/kg/day) or nortriptyline (NTP; 0, 10 or 20mg/kg/day) in drinking water. Long-term potentiation (LTP; 200 Hz) of the perforant path-dentate gyrus evoked potential was examined in urethane anesthetized rats after 30-32 days of DMI treatment. Short- (4-h) and long-term (24-h) spatial memory was tested in separate rats administered 0 or 7.5mg/kg/day DMI (25-30 days) using a two-trial spatial memory test. Additionally, the effects of chronically administered DMI and NTP were tested in rats using a two-trial, Object Recognition Test (ORT) at 2- and 24-h after 45 and 60 days of drug administration. Rats administered 3 or 7.5mg/kg/day DMI had attenuated LTP of the EPSP slope but not the population spike at the perforant path-dentate gyrus synapse. Short- and long-term memory for objects is differentially disrupted in rats after prolonged administration of DMI and NTP. Rats that were administered 7.5mg/kg/day DMI showed decreased memory for a two-trial spatial task when tested at 4-h. In the novel ORT, rats receiving 0 or 7.5mg/kg/day DMI showed a preference for the arm containing a Novel object when tested at both 2- and 24-h demonstrating both short- and long-term memory retention of the Familiar object. Rats that received either dose of NTP or 3mg/kg/day DMI showed impaired memory at 2-h, however this

  14. The effect of study-test modalities on the remembrance of subjective duration from long-term memory.

    Science.gov (United States)

    Klapproth, Florian

    2002-07-31

    It was examined whether stimulus modality (auditory vs. visual) affects the retrieval of subjective duration from memory. In two experiments the temporal generalization paradigm was used. Participants had to decide whether the previously learned standard duration (400 ms) occurred in the context of comparison stimuli. Two major results were found. (1) Discrimination was more accurate if the training and testing stimuli were of the same modality than if they were of opposite modalities. (2) If both modality of learning and modality of testing were different, subjects systematically underestimated the test durations, i.e. temporal generalization gradients (the proportion of identifications of a stimulus as the standard, plotted against stimulus duration) shifted to the right. The observed shift is interpreted as a result of a delayed timing process.

  15. Sequential Neighborhood Effects: The Effect of Long-Term Exposure to Concentrated Disadvantage on Children's Reading and Math Test Scores.

    Science.gov (United States)

    Hicks, Andrew L; Handcock, Mark S; Sastry, Narayan; Pebley, Anne R

    2018-02-01

    Prior research has suggested that children living in a disadvantaged neighborhood have lower achievement test scores, but these studies typically have not estimated causal effects that account for neighborhood choice. Recent studies used propensity score methods to account for the endogeneity of neighborhood exposures, comparing disadvantaged and nondisadvantaged neighborhoods. We develop an alternative propensity function approach in which cumulative neighborhood effects are modeled as a continuous treatment variable. This approach offers several advantages. We use our approach to examine the cumulative effects of neighborhood disadvantage on reading and math test scores in Los Angeles. Our substantive results indicate that recency of exposure to disadvantaged neighborhoods may be more important than average exposure for children's test scores. We conclude that studies of child development should consider both average cumulative neighborhood exposure and the timing of this exposure.

  16. Assessment of dynamic and long-term performance of an innovative multi-story timber building via structural monitoring and dynamic testing

    Science.gov (United States)

    Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Gaul, Andrew; Jager, Simon; Desgeorges, Yohann

    2012-04-01

    An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight non-composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of approximately 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The analysis of monitoring results starts with a discussion of the monitoring of long-term deformations. Next, the assessment of the floor vibration serviceability performance is outlined. Then, the forced vibration tests conducted on the whole building at different construction stages are reviewed. The system identification results from seismic shaking records are also discussed. Finally, updating of a finite element model of the building is conducted.

  17. Long-term chloride migration coefficient in slag cement-based concrete and resistivity as an alternative test method

    NARCIS (Netherlands)

    van Noort, R.; Hunger, M.; Spiesz, P.R.

    2016-01-01

    This article reports on investigations of the resistivity and chloride migration coefficient (DRCM) obtained in the accelerated Rapid Chloride Migration test for slag cement-based concretes. Determinations of the resistivity and DRCM were performed on 47 different concrete compositions, up to the

  18. Long Term Wave Climate at the Danish Test Site DanWEC Based on 35 Years Hindcast Data

    DEFF Research Database (Denmark)

    Tetu, Amélie; Jensen, Palle Martin; Kramer, Morten Mejlhede

    2017-01-01

    This paper presents an analysis of the wave climate of the DanWEC test site based on the 35 years hindcast data. This includes monthly and annual variation of the wave climate at the site together with an analysis of extreme events. This work includees results from the project “Resource Assessment...... and reduce WEC’s costs. The work so far has been concentrated on establishing the base for gaining detailed information on the wave and current climate at DanWEC. In this paper an analysis of the wave climate at the DanWEC test site based on 35 years modelled data will be presented. Relevant characteristics...... of the test site, such as scatter tables in terms of wave height and energy period (Hm0, Te) and weather window characteristics will be given. Based on 35 years of data gathered so far, an analysis of extreme events at the DanWEC test site is also included in this work....

  19. Infant Long-Term Memory for a Conditioned Response and Intelligence Test Performance at 2 Years of Age.

    Science.gov (United States)

    Fagen, Jeffrey W.; And Others

    To find predictive relations between measures taken in infancy and later scores on intelligence tests, a study was made that measured in the infant those cognitive processes examined later in life. Operant conditioning tasks were employed which required 3-, 7-, and 11-month-old infants to execute some response to produce an environmental…

  20. Residual N effect of long-term applications of cattle slurry using winter wheat as test crop

    DEFF Research Database (Denmark)

    Suarez, Alfonso; Thomsen, Ingrid Kaag; Rasmussen, Jim

    2018-01-01

    ) as reference treatments. In the test years, the customary nutrient treatments were withheld and each plot divided into six subplots randomly allocated increasing rates of mineral fertilizer N (0–250 kg N ha−1). The winter wheat yielded more in the first test year due to crop rotational effects and more benign...... climatic conditions, substantiating that more test years are needed when estimating residual N effects. The residual value of N added previously with NPK was negligible. In the first year, grain yields at N optimum were similar for NPK and SLU, but the amount of fertilizer N needed to reach optimum yield...... in cattle slurry (50, 100 and 150 kg total-N ha−1 termed ½, 1 and 1½ SLU), we estimated the residual N value over two consecutive growth periods (2014/2015 and 2015/2016). We used winter wheat as test crop and soils with a history of mineral fertilizers only (1 PK (no N)) and 1 NPK (100 kg N ha−1...

  1. Water permeability evaluation of hollow cylindrical reinforced concrete structure by means of long-term water penetration test with pressure

    International Nuclear Information System (INIS)

    Fujiwara, Ai; Miura, Norihiko; Konishi, Kazuhiro; Tsuji, Yukikazu

    2005-01-01

    In order to evaluate initial permeability of large concrete structure, hollow cylindrical reinforced concrete structure, having 6 m in outer diameter, 6 m in height, 1 m in thickness, had been tested by means of 0.25 MPa of outside water pressure. As the results, although surface cracking and partial separation of joint had been observed at the inner side, no water permeation through concrete could be happened even after 5.5 years. After this test, concrete core specimen showed less water penetration within the depth of concrete cover of reinforcement. Thus it was verified that this concrete structure had very high water-tightness, and that the initial average water permeability was estimated to be about 1.6 x 10 -12 m/s. (author)

  2. Tests of a photovoltaic pump: first results

    International Nuclear Information System (INIS)

    Petroselli, A.; Pica, M.; Biondi, P.

    2005-01-01

    The paper deals with a first series of tests conducted in Viterbo (42 deg 25 min North, 12 deg 06 min East) on a PV-DC pump. This series lasted eight months - from the first days of January to the end of August 2003 - and involved measurements of: air and PV-module temperatures; solar radiations, both on horizontal surface and tilted module surface; voltage and intensity of the DC currents from the panel; pump pressures and flow rates. In total, as much as 3,150 data were collected every day. The analysis of the data allowed to obtain some simple empirical relations expressing daily pumped water volumes, instantaneous flow rates and system efficiencies as a function of both radiations and total dynamic heads [it

  3. Long-term reactive transport modelling of stabilized/solidified waste: from dynamic leaching tests to disposal scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Windt, Laurent de [Ecole des Mines de Paris, CG-Hydrodynamics and Reaction Group, 35 R. St-Honore, 77300 Fontainebleau (France)]. E-mail: laurent.dewindt@ensmp.fr; Badreddine, Rabia [INERIS, Direction des Risques Chroniques, Unite Dechets et Sites Pollues, Parc Technologique Alata BP 2, 60550 Verneuil-en-Halatte (France); Lagneau, Vincent [Ecole des Mines de Paris, CG-Hydrodynamics and Reaction Group, 35 R. St-Honore, 77300 Fontainebleau (France)

    2007-01-31

    Environmental impact assessment of hazardous waste disposal relies, among others, on standardized leaching tests characterized by a strong coupling between diffusion and chemical processes. In that respect, this study shows that reactive transport modelling is a useful tool to extrapolate laboratory results to site conditions characterized by lower solution/solid (L/S) ratios, site specific geometry, infiltration, etc. A cement solidified/stabilized (S/S) waste containing lead is investigated as a typical example. The reactive transport model developed in a previous study to simulate the initial state of the waste as well as laboratory batch and dynamic tests is first summarized. Using the same numerical code (HYTEC), this model is then integrated to a simplified waste disposal scenario assuming a defective cover and rain water infiltration. The coupled evolution of the S/S waste chemistry and the pollutant plume migration are modelled assessing the importance of the cracking state of the monolithic waste. The studied configurations correspond to an undamaged and fully sealed system, a few main fractures between undamaged monoliths and, finally, a dense crack-network in the monoliths. The model considers the potential effects of cracking, first the increase of rain water and carbon dioxide infiltration and, secondly, the increase of L/S ratio and reactive surfaces, using either explicit fracture representation or dual porosity approaches.

  4. Long term test of buffer material at the Aespoe Hard Rock Laboratory, LOT project. Final report on the A2 test parcel

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, Ola; Olsson, Siv; Dueck, Ann; Birgersson, Martin; Nilsson, Ulf; Hernan-Haakansson, Tania (Clay Technology AB, Lund (Sweden)); Pedersen, Karsten (Microbial Analytics Sweden AB (Sweden); Goeteborg Univ., Dept. of Cell and Molecular Biology, Goeteborg (Sweden)); Nilsson, Sara; Eriksen, Trygve E. (School of Chemical Science and Engineering, Nuclear chemistry, Royal Inst. of Tech., Stockholm (Sweden)); Rosborg, Bo (Rosborg Consulting, Nykoeping (Sweden))

    2009-11-15

    In the Swedish repository concept for nuclear waste (KBS-3 concept), the spent nuclear fuel will be stored in copper canisters surrounded by compacted bentonite. The decaying power of the fuel will increase the temperature in the repository which, in combination with the uptake of ground-water, are expected to result in minor mineralogical changes in the bentonite. The ongoing LOT test series at the Aespoe Hard Rock Laboratory (HRL) are focused on identifying and quantifying such mineralogical alterations in the bentonite exposed to typical repository-like conditions. Further, buffer-related processes concerning copper corrosion, cation transport, and bacterial survival/activity are studied. In total, the LOT project includes seven test parcels, which contain a central Cu-tube surrounded by cylindrical bentonite blocks with a diameter of 30 cm, and gauges for temperature, total pressure, water pressure and humidity. Electrical heaters placed inside the copper tube are used to simulate the power from the decaying spent fuel. Three parcels are exposed to standard KBS-3 conditions (maximum temperature below 100 deg C) and four parcels to adverse conditions (maximum temperature below approx140 deg C). Both the standard and the adverse test series include short term tests (1 to 2 years), medium term tests (>5 years) and long term tests (>10 years). The present report concerns the A2 test parcel, which was a medium term test exposed to adverse conditions. Cu-coupons, 60Co tracers, bacteria and specific chemical substances were placed in the bentonite at defined positions. After field exposure, the entire test parcel was released from the rock by overlapping percussion drilling and wire sawing. The parcel was lifted and divided at test site and the bentonite material was sampled for specified analyses performed by nine different laboratories in five countries. The main aspects of the various tests and analyses may be summarized in the following items: - physical

  5. The Long-Term Effects of Silicone Hydrogel Contact Lenses on the Ocular Surface and Tear Function Tests

    Directory of Open Access Journals (Sweden)

    Yelda Yıldız Taşcı

    2014-05-01

    Full Text Available Objectives: To evaluate the effects of three different silicone hydrogel contact lenses, i.e. Balafilcon A (Pure Vision, Bausch & Lomb, Senofilcon A (Acuvue Oasys, Johnson & Johnson, and Confilcon A (Biofinity, CooperVision, on ocular surface after one, three, and sıx months of wear. Materials and Methods: Silicone hydrogel contact lenses (SHCL were fitted to 58 patients (Balafilcon A to 40 eyes: Group 1, Senofilcon A to 42 eyes: Group 2, and Confilcon A to 34 eyes: Group 3 who have not used any contact lenses before. All groups were graded according to the Cornea and Contact Lens Research Unit’s grading score, and were performed ocular surface disease index scoring (OSDI, tear break-up time (BUT, and Schirmer 1 test. Results: The mean age was 22.45±5.96, 20.76±3.70, 21.00±3.84 years in Groups 1,2, and 3, respectively (p>0.05. While the increase in papillary hypertrophy as well as palpebral and bulbar hyperemia at 1st month in Group 1 and at 6th month at Group 2 were significant, there were no change in Group 3 with the use of SHCL (p0.05. In Group 3, the Schirmer test was lower than in Groups 1 and 2, which was statistically significant (p=0.048, p=0.003. Conclusion: Factors like lens material, modulus, the presence of an internal wetting agent, and water content play an important role in the effects of SHCL on the ocular surface. In this study, it is demonstrated that SHCL does not cause clinically significant dry eye. (Turk J Ophthalmol 2014; 44: 201-6

  6. Usefulness of desmopressin testing to predict relapse during long-term follow-up in patients in remission from Cushing’s disease

    Directory of Open Access Journals (Sweden)

    Alberto Giacinto Ambrogio

    2017-11-01

    Full Text Available Recurrence of Cushing’s disease after successful transsphenoidal surgery occurs in some 30% of the patients and the response to desmopressin shortly after surgery has been proposed as a marker for disease recurrence. The aim of the present study was to evaluate the response to desmopressin over time after surgery. We tested 56 patients with Cushing’s disease in remission after transsphenoidal surgery with desmopressin for up to 20 years after surgery. The ACTH and cortisol response to desmopressin over time was evaluated in patients on long-term remission or undergoing relapse; an increase by at least 27 pg/mL in ACTH levels identified responders. The vast majority of patients who underwent successful adenomectomy failed to respond to desmopressin after surgery and this response pattern was maintained over time in patients on long-term remission. Conversely, a response to desmopressin reappeared in patients who subsequently developed a recurrence of Cushing’s disease, even years prior to frank hypercortisolism. It appears therefore that a change in the response pattern to desmopressin proves predictive of recurrence of Cushing’s disease and may indicate which patients require close monitoring.

  7. Measurements on cation exchange capacity of bentonite in the long-term test of buffer material (LOT)

    International Nuclear Information System (INIS)

    Muurinen, A.

    2011-01-01

    Determination of cation exchange capacity (CEC) of bentonite in the LOT experiment was the topic of this study. The measurements were performed using the complex of copper(II) ion with trietylenetetramine [Cu(trien)] 2+ as the index cation. Testing of the determination method suggested that (i) drying and wetting of the bentonite, and (ii) exchange time affect the obtained result. The real CEC measurements were carried out with the bentonite samples taken from the A2 parcel of the LOT experiment. The CEC values of the LOT samples were compared with those of the reference samples taken from the same bentonite batch before the compaction of the blocks for the experiment. The conclusions drawn have been made on the basis of the results determined with the wet bentonite samples using the direct exchange of two weeks with 0.01 M [Cu(trien)] 2+ solution because this method gave the most complete cation exchange in the CEC measurements. The differences between the samples taken from different places of the A2 parcel were quite small and close to the accuracy of the method. However, it seems that the CEC values of the field experiment are somewhat higher than the CEC of the reference samples and the values of the hot area are higher than those obtained from the low temperature area. It is also obvious that the variation of CEC increases with increasing temperature. (orig.)

  8. Biodiversity-ecosystem functioning relationships in long-term time series and palaeoecological records: deep sea as a test bed.

    Science.gov (United States)

    Yasuhara, Moriaki; Doi, Hideyuki; Wei, Chih-Lin; Danovaro, Roberto; Myhre, Sarah E

    2016-05-19

    The link between biodiversity and ecosystem functioning (BEF) over long temporal scales is poorly understood. Here, we investigate biological monitoring and palaeoecological records on decadal, centennial and millennial time scales from a BEF framework by using deep sea, soft-sediment environments as a test bed. Results generally show positive BEF relationships, in agreement with BEF studies based on present-day spatial analyses and short-term manipulative experiments. However, the deep-sea BEF relationship is much noisier across longer time scales compared with modern observational studies. We also demonstrate with palaeoecological time-series data that a larger species pool does not enhance ecosystem stability through time, whereas higher abundance as an indicator of higher ecosystem functioning may enhance ecosystem stability. These results suggest that BEF relationships are potentially time scale-dependent. Environmental impacts on biodiversity and ecosystem functioning may be much stronger than biodiversity impacts on ecosystem functioning at long, decadal-millennial, time scales. Longer time scale perspectives, including palaeoecological and ecosystem monitoring data, are critical for predicting future BEF relationships on a rapidly changing planet. © 2016 The Author(s).

  9. Method validation and verification in liquid scintillation counting using the long-term uncertainty method (LTUM) on two decades of proficiency test data

    International Nuclear Information System (INIS)

    Verrezen, F.; Vasile, M.; Loots, H.; Bruggeman, M.

    2017-01-01

    Results from proficiency tests gathered over the past two decades by the laboratory for low level radioactivity measurements for liquid scintillation counting of 3 H (184 results) and 14 C (74 results) are used to verify the validated measurement methods used by the laboratory, in particular the estimated uncertainty budget of the method and its reproducibility and stability. A linear regression approach is used for the analysis of the results, described in the literature as the long term uncertainty in measurement method. The present study clearly indicates the advantages of using proficiency test results in identifying possible constant or proportional bias effects as well as the possibility to compare the laboratory performance with the performance of peer laboratories. (author)

  10. Introduction: Long term prediction

    International Nuclear Information System (INIS)

    Beranger, G.

    2003-01-01

    Making a decision upon the right choice of a material appropriate to a given application should be based on taking into account several parameters as follows: cost, standards, regulations, safety, recycling, chemical properties, supplying, transformation, forming, assembly, mechanical and physical properties as well as the behaviour in practical conditions. Data taken from a private communication (J.H.Davidson) are reproduced presenting the life time range of materials from a couple of minutes to half a million hours corresponding to applications from missile technology up to high-temperature nuclear reactors or steam turbines. In the case of deep storage of nuclear waste the time required is completely different from these values since we have to ensure the integrity of the storage system for several thousand years. The vitrified nuclear wastes should be stored in metallic canisters made of iron and carbon steels, stainless steels, copper and copper alloys, nickel alloys or titanium alloys. Some of these materials are passivating metals, i.e. they develop a thin protective film, 2 or 3 nm thick - the so-called passive films. These films prevent general corrosion of the metal in a large range of chemical condition of the environment. In some specific condition, localized corrosion such as the phenomenon of pitting, occurs. Consequently, it is absolutely necessary to determine these chemical condition and their stability in time to understand the behavior of a given material. In other words the corrosion system is constituted by the complex material/surface/medium. For high level nuclear wastes the main features for resolving problem are concerned with: geological disposal; deep storage in clay; waste metallic canister; backfill mixture (clay-gypsum) or concrete; long term behavior; data needed for modelling and for predicting; choice of appropriate solution among several metallic candidates. The analysis of the complex material/surface/medium is of great importance

  11. Long-Term Symbolic Learning

    National Research Council Canada - National Science Library

    Kennedy, William G; Trafton, J. G

    2007-01-01

    What are the characteristics of long-term learning? We investigated the characteristics of long-term, symbolic learning using the Soar and ACT-R cognitive architectures running cognitive models of two simple tasks...

  12. ''Is it really green?'' Long-term performance of monocrystalline solar modules as illustrated by the example of a photovoltaic pumping station in a natural reserve (''Schwenninger Moos''); ''Is it really green?'' Langzeiterfahrung mit monokristallinen Solarmodulen am Beispiel der photovoltaischen Pumpstation Schwenninger Moos

    Energy Technology Data Exchange (ETDEWEB)

    Assbeck, Franz [Hochschule Furtwangen (Germany). Fakultaet Computer und Electrical Engineering

    2010-03-15

    In 1991, a photovoltaic pumping station was commissioned in the natural reserve ''Schwenninger Moos'' in the southern Black Forest. The pumping station was dismantled when the land was used for the 2010 Baden-Wuerttemberg 'Landesgartenschau' (garden festival). After 18 years of operation, the plant provided valuable information on the long-term performance of monocrystalline solar modules, so the author made detailed measurements and evaluations just before the plant was dismantled, in an attempt to find out about its long-term performance and cost efficiency. The results are presented here. (orig.)

  13. Linking women who test HIV-positive in pregnancy-related services to long-term HIV care and treatment services: a systematic review.

    Science.gov (United States)

    Ferguson, Laura; Grant, Alison D; Watson-Jones, Deborah; Kahawita, Tanya; Ong'ech, John O; Ross, David A

    2012-05-01

    To quantify attrition between women testing HIV-positive in pregnancy-related services and accessing long-term HIV care and treatment services in low- or middle-income countries and to explore the reasons underlying client drop-out by synthesising current literature on this topic. A systematic search in Medline, EMBASE, Global Health and the International Bibliography of the Social Sciences of literature published 2000-2010. Only studies meeting pre-defined quality criteria were included. Of 2543 articles retrieved, 20 met the inclusion criteria. Sixteen (80%) drew on data from sub-Saharan Africa. The pathway between testing HIV-positive in pregnancy-related services and accessing long-term HIV-related services is complex, and attrition was usually high. There was a failure to initiate highly active antiretroviral therapy (HAART) among 38-88% of known-eligible women. Providing 'family-focused care', and integrating CD4 testing and HAART provision into prevention of mother-to-child HIV transmission services appear promising for increasing women's uptake of HIV-related services. Individual-level factors that need to be addressed include financial constraints and fear of stigma. Too few women negotiate the many steps between testing HIV-positive in pregnancy-related services and accessing HIV-related services for themselves. Recent efforts to stem patient drop-out, such as the MTCT-Plus Initiative, hold promise. Addressing barriers and enabling factors both within health facilities and at the levels of the individual woman, her family and society will be essential to improve the uptake of services. © 2012 Blackwell Publishing Ltd.

  14. LONG TERM COLLECTIONS

    CERN Multimedia

    STAFF ASSOCIATION

    2010-01-01

    ACKNOWLEDGMENTS The Long-Term Collections (CLT) committee would like to warmly thank its faithful donors who, year after year, support our actions all over the world. Without you, all this would not be possible. We would like to thank, in particular, the CERN Firemen’s Association who donated 5000 CHF in the spring thanks to the sale of their traditional calendar, and the generosity of the CERN community. A huge thank you to the firemen for their devotion to our cause. And thank you to all those who have opened their door, their heart, and their purses! Similarly, we warmly thank the CERN Yoga Club once again for its wonderful donation of 2000 CHF we recently received. We would also like to tell you that all our projects are running well. Just to remind you, we are currently supporting the activities of the «Réflexe-Partage» Association in Mali; the training centre of «Education et Développement» in Abomey, Benin; and the orphanage and ...

  15. AZ-101 Mixer Pump Test Qualification Test Procedures (QTP)

    International Nuclear Information System (INIS)

    THOMAS, W.K.

    2000-01-01

    Describes the Qualification test procedure for the AZ-101 Mixer Pump Data Acquisition System (DAS). The purpose of this Qualification Test Procedure (QTP) is to confirm that the AZ-101 Mixer Pump System has been properly programmed and hardware configured correctly. This QTP will test the software setpoints for the alarms and also check the wiring configuration from the SIMcart to the HMI. An Acceptance Test Procedure (ATP), similar to this QTP will be performed to test field devices and connections from the field

  16. Preliminary Field Tests and Long-Term Monitoring as a Method of Design Risk Mitigation: A Case Study of Gdańsk Deepwater Container Terminal

    Directory of Open Access Journals (Sweden)

    Miśkiewicz Mikołaj

    2017-09-01

    Full Text Available Appropriate risk assessment plays a fundamental role in the design. . The authors propose a possible method of design risk mitigation, which follows recommendations included in Eurocode 7. The so-called “Observational Method” (OM can produce savings in costs and programmes on engineering projects without compromising safety. The case study presented is a complex design solution that deals with the heavy foundations of a gantry crane beam as one of the elements of a Deepwater Container Terminal extension. The paper presents a detailed process of the design of the rear crane beam being a part of the brand new berth, together with its static analysis, as well as the long-term results of observations, which have revealed the real performance of the marine structure. The case presented is based on excessive preliminary field tests and technical monitoring of the structure, and is an example of a successful OM implementation and design risk mitigation.

  17. Microscopic mapping of specific contact resistances and long-term reliability tests on 4H-silicon carbide using sputtered titanium tungsten contacts for high temperature device applications

    Science.gov (United States)

    Lee, S.-K.; Zetterling, C.-M.; Ostling, M.

    2002-07-01

    We report on the microscopic mapping of specific contact resistances (rhoc) and long-term reliability tests using sputtered titanium tungsten (TiW) ohmic contacts to highly doped n-type epilayers of 4H-silicon carbide. The TiW ohmic contacts showed good uniformity with low contact resistivity of 3.3 x10-5 Omega cm2. Microscopic mapping of the rhoc showed that the rhoc had a distribution that decreased from the center to the edge of the wafer. This distribution of the rhoc is caused by variation of the doping concentration of the wafer. Sacrificial oxidation at high temperature partially recovered inductively coupled plasma etch damage. TiW contacts with platinum and gold capping layers have stable specific contact resistance at 500 and 600 degC in a vacuum chamber for 308 h.

  18. Evaluating long term forecasts

    Energy Technology Data Exchange (ETDEWEB)

    Lady, George M. [Department of Economics, College of Liberal Arts, Temple University, Philadelphia, PA 19122 (United States)

    2010-03-15

    The U.S. Department of Energy's Energy Information Administration (EIA), and its predecessor organizations, has published projections of U.S. energy production, consumption, distribution and prices annually for over 30 years. A natural issue to raise in evaluating the projections is an assessment of their accuracy compared to eventual outcomes. A related issue is the determination of the sources of 'error' in the projections that are due to differences between the actual versus realized values of the associated assumptions. One way to do this would be to run the computer-based model from which the projections are derived at the time the projected values are realized, using actual rather than assumed values for model assumptions; and, compare these results to the original projections. For long term forecasts, this approach would require that the model's software and hardware configuration be archived and available for many years, possibly decades, into the future. Such archival creates many practical problems; and, in general, it is not being done. This paper reports on an alternative approach for evaluating the projections. In the alternative approach, the model is run many times for cases in which important assumptions are changed individually and in combinations. A database is assembled from the solutions and a regression analysis is conducted for each important projected variable with the associated assumptions chosen as exogenous variables. When actual data are eventually available, the regression results are then used to estimate the sources of the differences in the projections of the endogenous variables compared to their eventual outcomes. The results presented here are for residential and commercial sector natural gas and electricity consumption. (author)

  19. Effects of testing on subsequent re-encoding and long-term forgetting of action-relevant materials: On the influence of recall type.

    Science.gov (United States)

    Kubik, Veit; Nilsson, Lars-Göran; Olofsson, Jonas K; Jönsson, Fredrik U

    2015-10-01

    Testing one's memory of previously studied information reduces the rate of forgetting, compared to restudy. However, little is known about how this direct testing effect applies to action phrases (e.g., "wash the car") - a learning material relevant to everyday memory. As action phrases consist of two different components, a verb (e.g., "wash") and a noun (e.g., "car"), testing can either be implemented as noun-cued recall of verbs or verb-cued recall of nouns, which may differently affect later memory performance. In the present study, we investigated the effect of testing for these two recall types, using verbally encoded action phrases as learning materials. Results showed that repeated study-test practice, compared to repeated study-restudy practice, decreased the forgetting rate across 1 week to a similar degree for both noun-cued and verb-cued recall types. However, noun-cued recall of verbs initiated more new subsequent learning during the first restudy, compared to verb-cued recall of nouns. The study provides evidence that testing has benefits on both subsequent restudy and long-term retention of action-relevant materials, but that these benefits are differently expressed with testing via noun-cued versus verb-cued recall. © 2015 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  20. Elevated rheumatoid factor and long term risk of rheumatoid arthritis

    DEFF Research Database (Denmark)

    Nielsen, Sune F; Bojesen, Stig E; Schnohr, Peter

    2012-01-01

    To test whether elevated concentration of rheumatoid factor is associated with long term development of rheumatoid arthritis.......To test whether elevated concentration of rheumatoid factor is associated with long term development of rheumatoid arthritis....

  1. K-Basin sludge treatment facility pump test report

    International Nuclear Information System (INIS)

    SQUIER, D.M.

    1999-01-01

    Tests of a disc pump and a dual diaphragm pump are stymied by pumping a metal laden fluid. Auxiliary systems added to a diaphragm pump might enable the transfer of such fluids, but the additional system complexity is not desirable for remotely operated and maintained systems

  2. Estimating Aquifer Properties Using Sinusoidal Pumping Tests

    Science.gov (United States)

    Rasmussen, T. C.; Haborak, K. G.; Young, M. H.

    2001-12-01

    We develop the theoretical and applied framework for using sinusoidal pumping tests to estimate aquifer properties for confined, leaky, and partially penetrating conditions. The framework 1) derives analytical solutions for three boundary conditions suitable for many practical applications, 2) validates the analytical solutions against a finite element model, 3) establishes a protocol for conducting sinusoidal pumping tests, and 4) estimates aquifer hydraulic parameters based on the analytical solutions. The analytical solutions to sinusoidal stimuli in radial coordinates are derived for boundary value problems that are analogous to the Theis (1935) confined aquifer solution, the Hantush and Jacob (1955) leaky aquifer solution, and the Hantush (1964) partially penetrated confined aquifer solution. The analytical solutions compare favorably to a finite-element solution of a simulated flow domain, except in the region immediately adjacent to the pumping well where the implicit assumption of zero borehole radius is violated. The procedure is demonstrated in one unconfined and two confined aquifer units near the General Separations Area at the Savannah River Site, a federal nuclear facility located in South Carolina. Aquifer hydraulic parameters estimated using this framework provide independent confirmation of parameters obtained from conventional aquifer tests. The sinusoidal approach also resulted in the elimination of investigation-derived wastes.

  3. The Entrance test of physics and Workbook in teaching of physics at secondary vocational school within long-term pedagogical research

    Science.gov (United States)

    Kerlínová, Věra

    2017-01-01

    Within the long-term pedagogical research ongoing since the school year 2008/2009 to 2015/2016 at the secondary vocational school in Bohumín was through of Entrance test of physics, which included curriculum of the sixth to ninth year of elementary school, regularly finding out, in which parts of Entrance test - Unit conversions, International System of Units, Properties of matter, Mechanics, Thermodynamics, Electricity and Magnetism, Optics, Atoms and Universe - pupils of the 1st years of secondary vocational school, technical and non-technical, reach a higher number of correct answers, in which dominates the wrong answers and which parts of the test pupils are better left out completely. It turned out that the results of these tests are very informative not only for theoretical and practical teaching, but also technical and other science subjects. The results of the Entrance tests are also a valuable source of information for continuous innovation Workbook of Physics - Mechanics for the 1st year of secondary vocational schools [1] - whose the first version began during the school year 2007/2008 and which was tested within pre-research in school years 2008/2009, 2009/2010 and within research in school year 2010/2011. On the basis of feedbacks getting from research the Workbook is regularly expanded, innovated and updated. The Workbook consists of parts dedicated to physical concepts, physical tasks, proposals to physical experiments, pupils comments from viewed video projection and documentary films, examples from the world of science and technology, examples from practice and real life, physical terminology in English, quizzes, competitions, interesting things and links related to discussed curriculum. The Workbook is divided into thematic sections, chapters and subchapters similar as physics textbooks for pupils of the 1st years of Secondary Schools in the Czech Republic. In the Workbook there are included tasks on fill in the words, polynomial tasks with

  4. Long-term wireless pH monitoring of the distal esophagus: prolonging the test beyond 48 hours is unnecessary and may be misleading.

    Science.gov (United States)

    Capovilla, G; Salvador, R; Spadotto, L; Voltarel, G; Pesenti, E; Perazzolo, A; Nicoletti, L; Merigliano, S; Costantini, M

    2017-10-01

    Wireless pH monitoring of the esophagus has been widely used to detect GERD for more than a decade. It is generally well tolerated and accepted by patients, but it is still unclear whether prolonging a recording beyond the usual 48 hours can improve the test's diagnostic value. The aim of this study is to examine the diagnostic yield of 96-hour pH monitoring vis-à-vis 24- and 48-hour tests, and to ascertain whether any gain in diagnostic terms was of genuine clinical utility. Patients with suspected GERD underwent 4-day PPI-off wireless pH monitoring of the distal esophagus. The capsule was inserted under endoscopic control, 6 cm above the squamocolumnar junction. Average acid exposure time was calculated after 24, 48, and 96 hours of recording. Ninety-nine patients completed the 96 hour test, and formed the study sample. The wireless test method was used in 42 patients (42.4%) unable to tolerate the traditional pH-monitoring catheter, and in 57 (57.6%) with a previous negative pH study despite symptoms suggestive of GERD. On complete analysis, 47 patients (47.5%) had a pathological test result: 19 patients within the first 24 hours (19.2%, 24 hour group); another 16 after 48 hours (+16.2%, 48 hour group), and a further 12 (+12.1%, 96 hour group) only after 96 hours of monitoring. All 47 patients with an abnormal acid exposure were offered and accepted surgery (10 patients) or medical therapy (37 patients). Clinical follow-up was obtained in all patients with a positive Bravo test result after a median 67 months (IQR: 38-98) using a validated symptom questionnaire. A good outcome after fundoplication or medical therapy was achieved in 73.7% of patients in the 24 hour group, in 62.5% of those in the 48 hour group, and in only 25% of those in the 96 hour group, P = 0.02. Long-term wireless pH monitoring enables an increase in the diagnostic yield over traditional 24- and 48-hour pH studies, but prolonging the test may constitute an unwanted bias and prompt the

  5. [The Brumory test, an incidental long-term memory task designed for foreign, non-French-speaking people with low educational level].

    Science.gov (United States)

    Vanderaspoilden, V; Nury, D; Frisque, J; Peigneux, P

    2015-12-01

    Cognitive assessment among foreign patients is a growing need for several reasons: foreign patients have a different culture, they have an insufficient command of the language of the consulting center, and the available cognitive tools are largely unsuitable. For these reasons, we developed a non-verbal test of long-term memory called the Brumory test. This test is based on incident encoding of 48 colored images followed by retrieval by recognition. We compared the performance of indigenous participants with that of immigrant participants (mainly from Morocco). Immigrant participants did not speak French properly and had a low educational level. The results indicate no significant difference in memory performance between the two groups of participants. Moreover, the instructions were easily understood by immigrant participants, despite the fact they do not master French. We conclude that the Brumory test is an appropriate test to assess memory among foreign non-French-speaking patients people with low educational level. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Genetic testing for BRCA1: effects of a randomised study of knowledge provision on interest in testing and long term test uptake; implications for the NICE guidelines.

    Science.gov (United States)

    Hall, Julia; Gray, Susan; A'Hern, Roger; Shanley, Susan; Watson, Maggie; Kash, Kathryn; Croyle, Robert; Eeles, Rosalind

    2009-01-01

    Interest in searching for mutations in BRCA1 and BRCA2 is high. Knowledge regarding these genes and the advantages and limitations of genetic testing is limited. It is unknown whether increasing knowledge about breast cancer genetic testing alters interest in testing. Three hundred and seventy nine women (260 with a family history of breast cancer; 119 with breast cancer) from The Royal Marsden NHS Foundation Trust were randomised to receive or not receive written educational information on cancer genetics. A questionnaire was completed assessing interest in BRCA1 testing and knowledge on breast cancer genetics and screening. Actual uptake of BRCA1 testing is reported with a six year follow-up. Eighty nine percent of women at risk of breast cancer and 76% of women with breast cancer were interested in BRCA1 testing (P testing, the families of 66% of the at risk group and 13% of the women with breast cancer would be eligible for testing (probability of BRCA1 mutation >or=20%). Within six years of randomisation, genetic testing was actually undertaken on 12 women, only 10 of whom would now be eligible, on the NICE guidelines. There is strong interest in BRCA1 testing. Despite considerable ignorance of factors affecting the inheritance of breast cancer, education neither reduced nor increased interest to undergo testing. The NICE guidelines successfully triage those with a high breast cancer risk to be managed in cancer genetics clinics.

  7. Dynamic Strength and Accumulated Plastic Strain Development Laws and Models of the Remolded Red Clay under Long-Term Cyclic Loads: Laboratory Test Results

    Directory of Open Access Journals (Sweden)

    Li Jian

    2015-09-01

    Full Text Available The dynamic strength and accumulated plastic strain are two important parameters for evaluating the dynamic response of soil. As a special clay, the remolded red clay is often used as the high speed railway subgrade filling, but studies on its dynamic characteristics are few. For a thorough analysis of the suitability of the remolded red clay as the subgrade filling, a series of long-term cyclic load triaxial test under different load histories are carried out. Considering the influence of compactness, confining pressure, consolidation ratio, vibration frequency and dynamic load to the remolded red clay dynamic property, the tests obtain the development curves of the dynamic strength and accumulated plastic strain under different test conditions. Then, through curve fitting method, two different hyperbolic models respectively for the dynamic strength and accumulated plastic strain are built, which can match the test datum well. By applying the dynamic strength model, the critical dynamic strength of the remolded red clay are gained. Meanwhile, for providing basic datum and reference for relevant projects, all key parameters for the dynamic strength and accumulated plastic strain of the remolded red clay are given in the paper.

  8. Decant pump assembly and controls qualification testing - test report

    Energy Technology Data Exchange (ETDEWEB)

    Staehr, T.W., Westinghouse Hanford

    1996-05-02

    This report summarizes the results of the qualification testing of the supernate decant pump and controls system to be used for in-tank sludge washing in aging waste tank AZ-101. The test was successful and all components are qualified for installation and use in the tank.

  9. Long Term Financing of Infrastructure

    OpenAIRE

    Sinha, Sidharth

    2014-01-01

    Infrastructure projects, given their long life, require long term financing. The main sources of long term financings are insurance and pension funds who seek long term investments with low credit risk. However, in India household financial savings are mainly invested in bank deposits. Insurance and pension funds account for only a small percentage of household financial savings. In addition most infrastructure projects do not qualify for investment by insurance and pension funds because of t...

  10. Field Performance Test of an Air-Cleaner with Photocatalysis-Plasma Synergistic Reactors for Practical and Long-Term Use

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ochiai

    2014-10-01

    Full Text Available A practical and long-term usable air-cleaner based on the synergy of photocatalysis and plasma treatments has been developed. A field test of the air-cleaner was carried out in an office smoking room. The results were compared to previously reported laboratory test results. Even after a treatment of 12,000 cigarettes-worth of tobacco smoke, the air-cleaner maintained high-level air-purification activity (98.9% ± 0.1% and 88% ± 1% removal of the total suspended particulate (TSP and total volatile organic compound (TVOC concentrations, respectively at single-pass conditions. Although the removal ratio of TSP concentrations was 98.6% ± 0.2%, the ratio of TVOC concentrations was 43.8% after a treatment of 21,900 cigarettes-worth of tobacco smoke in the field test. These results indicate the importance of suitable maintenance of the reactors in the air-cleaner during field use.

  11. Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

    Directory of Open Access Journals (Sweden)

    Afshin Hedayat

    2017-08-01

    Full Text Available In this paper, a complete station blackout (SBO or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR. The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank, safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal–hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

  12. Simulation and transient analyses of a complete passive heat removal system in a downward cooling pool-type material testing reactor against a complete station blackout and long-term natural convection mode using the RELAP5/3.2 code

    Energy Technology Data Exchange (ETDEWEB)

    Hedayat, Afshin [Reactor and Nuclear Safety School, Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of)

    2017-08-15

    In this paper, a complete station blackout (SBO) or complete loss of electrical power supplies is simulated and analyzed in a downward cooling 5-MW pool-type Material Testing Reactor (MTR). The scenario is traced in the absence of active cooling systems and operators. The code nodalization is successfully benchmarked against experimental data of the reactor's operating parameters. The passive heat removal system includes downward water cooling after pump breakdown by the force of gravity (where the coolant streams down to the unfilled portion of the holdup tank), safety flapper opening, flow reversal from a downward to an upward cooling direction, and then the upward free convection heat removal throughout the flapper safety valve, lower plenum, and fuel assemblies. Both short-term and long-term natural core cooling conditions are simulated and investigated using the RELAP5 code. Short-term analyses focus on the safety flapper valve operation and flow reversal mode. Long-term analyses include simulation of both complete SBO and long-term operation of the free convection mode. Results are promising for pool-type MTRs because this allows operators to investigate RELAP code abilities for MTR thermal–hydraulic simulations without any oscillation; moreover, the Tehran Research Reactor is conservatively safe against the complete SBO and long-term free convection operation.

  13. Short-term delayed recall of auditory verbal learning test is equivalent to long-term delayed recall for identifying amnestic mild cognitive impairment.

    Directory of Open Access Journals (Sweden)

    Qianhua Zhao

    Full Text Available Delayed recall of words in a verbal learning test is a sensitive measure for the diagnosis of amnestic mild cognitive impairment (aMCI and early Alzheimer's disease (AD. The relative validity of different retention intervals of delayed recall has not been well characterized. Using the Auditory Verbal Learning Test-Huashan version, we compared the differentiating value of short-term delayed recall (AVL-SR, that is, a 3- to 5-minute delay time and long-term delayed recall (AVL-LR, that is, a 20-minute delay time in distinguishing patients with aMCI (n = 897 and mild AD (n = 530 from the healthy elderly (n = 1215. In patients with aMCI, the correlation between AVL-SR and AVL-LR was very high (r = 0.94, and the difference between the two indicators was less than 0.5 points. There was no difference between AVL-SR and AVL-LR in the frequency of zero scores. In the receiver operating characteristic curves analysis, although the area under the curve (AUC of AVL-SR and AVL-LR for diagnosing aMCI was significantly different, the cut-off scores of the two indicators were identical. In the subgroup of ages 80 to 89, the AUC of the two indicators showed no significant difference. Therefore, we concluded that AVL-SR could substitute for AVL-LR in identifying aMCI, especially for the oldest patients.

  14. Long-term impact of pre-operative physical rehabilitation protocol on the 6-min walk test of patients with adolescent idiopathic scoliosis: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    V.L. dos Santos Alves

    2015-05-01

    Full Text Available Background: Monitored physical activities in patients with adolescent idiopathic scoliosis (AIS have been shown to improve physical performance, endurance and cardiopulmonary function and may be assessed by the 6-min walk test (6MWT. We aimed to evaluate the long-term results of the 6MWT after a rehabilitation protocol employed before surgical correction for AIS. Methods: This prospective randomized clinical trial studied the impact of a 4-month pre-operative physical rehabilitation protocol on post-operative cardiopulmonary function and physical endurance, by using the 6MWT, in patients with AIS submitted to surgical correction, comparing them to matched controls without physical rehabilitation. Studied variables were heart and respiratory rate, systolic and diastolic blood pressure, peripheral blood oxygen saturation, Borg score, and distance walked. Patients were assessed at baseline, after 4 months of rehabilitation, and 3, 6 and 12 months post-operatively. Results: A total of 50 patients with AIS were included in the study and allocated blindly, by simple randomization, into either one of the two groups, with 25 patients each: study group (pre-operative physical rehabilitation and control group. The physical rehabilitation protocol promoted significant progressive improvement in heart and respiratory rate, peripheral blood oxygen saturation, distance walked, and level of effort assessed by the Borg scale after surgery. Conclusions: Post-surgical recovery, evaluated by 6MWT, was significantly better in patients who underwent a 4-month pre-operative physical rehabilitation protocol. Keywords: Scoliosis, Exercise, Exercise movement techniques, Exercise therapy, Exercise test

  15. An empirical test of the 'shark nursery area concept' in Texas bays using a long-term fisheries-independent data set

    Science.gov (United States)

    Froeschke, John T.; Stunz, Gregory W.; Sterba-Boatwright, Blair; Wildhaber, Mark L.

    2010-01-01

    Using a long-term fisheries-independent data set, we tested the 'shark nursery area concept' proposed by Heupel et al. (2007) with the suggested working assumptions that a shark nursery habitat would: (1) have an abundance of immature sharks greater than the mean abundance across all habitats where they occur; (2) be used by sharks repeatedly through time (years); and (3) see immature sharks remaining within the habitat for extended periods of time. We tested this concept using young-of-the-year (age 0) and juvenile (age 1+ yr) bull sharks Carcharhinus leucas from gill-net surveys conducted in Texas bays from 1976 to 2006 to estimate the potential nursery function of 9 coastal bays. Of the 9 bay systems considered as potential nursery habitat, only Matagorda Bay satisfied all 3 criteria for young-of-the-year bull sharks. Both Matagorda and San Antonio Bays met the criteria for juvenile bull sharks. Through these analyses we examined the utility of this approach for characterizing nursery areas and we also describe some practical considerations, such as the influence of the temporal or spatial scales considered when applying the nursery role concept to shark populations.

  16. Mixer pump test plan for double shell tank AZ-101

    International Nuclear Information System (INIS)

    STAEHR, T.W.

    1999-01-01

    Mixer pump systems have been chosen as the method for retrieval of tank wastes contained in double shell tanks at Hanford. This document describes the plan for testing and demonstrating the ability of two 300 hp mixer pumps to mobilize waste in tank AZ-101. The mixer pumps, equipment and instrumentation to monitor the test were installed by Project W-151

  17. A spatially-supported forced-choice recognition test reveals children’s long-term memory for newly learned word forms

    Directory of Open Access Journals (Sweden)

    Katherine R. Gordon

    2014-03-01

    Full Text Available Children’s memories for the link between a newly trained word and its referent have been the focus of extensive past research. However, memory for the word form itself is rarely assessed among preschool-age children. When it is, children are typically asked to verbally recall the forms, and they generally perform at floor on such tests. To better measure children’s memory for word forms, we aimed to design a more sensitive test that required recognition rather than recall, provided spatial cues to off-set the phonological memory demands of the test, and allowed pointing rather than verbal responses. We taught 12 novel word-referent pairs via ostensive naming to sixteen 4-to-6-year-olds and measured their memory for the word forms after a week-long retention interval using the new spatially-supported form recognition test. We also measured their memory for the word-referent links and the generalization of the links to untrained referents with commonly used recognition tests. Children demonstrated memory for word forms at above chance levels; however, their memory for forms was poorer than their memory for trained or generalized word-referent links. When in error, children were no more likely to select a foil that was a close neighbor to the target form than a maximally different foil. Additionally, they more often selected correct forms that were among the first six than the last six to be trained. Overall, these findings suggest that children are able to remember word forms after a limited number of ostensive exposures and a long-term delay. However, word forms remain more difficult to learn than word-referent links and there is an upper limit on the number of forms that can be learned within a given period of time.

  18. Long-term Cost-Effectiveness of Diagnostic Tests for Assessing Stable Chest Pain: Modeled Analysis of Anatomical and Functional Strategies.

    Science.gov (United States)

    Bertoldi, Eduardo G; Stella, Steffan F; Rohde, Luis E; Polanczyk, Carisi A

    2016-05-01

    Several tests exist for diagnosing coronary artery disease, with varying accuracy and cost. We sought to provide cost-effectiveness information to aid physicians and decision-makers in selecting the most appropriate testing strategy. We used the state-transitions (Markov) model from the Brazilian public health system perspective with a lifetime horizon. Diagnostic strategies were based on exercise electrocardiography (Ex-ECG), stress echocardiography (ECHO), single-photon emission computed tomography (SPECT), computed tomography coronary angiography (CTA), or stress cardiac magnetic resonance imaging (C-MRI) as the initial test. Systematic review provided input data for test accuracy and long-term prognosis. Cost data were derived from the Brazilian public health system. Diagnostic test strategy had a small but measurable impact in quality-adjusted life-years gained. Switching from Ex-ECG to CTA-based strategies improved outcomes at an incremental cost-effectiveness ratio of 3100 international dollars per quality-adjusted life-year. ECHO-based strategies resulted in cost and effectiveness almost identical to CTA, and SPECT-based strategies were dominated because of their much higher cost. Strategies based on stress C-MRI were most effective, but the incremental cost-effectiveness ratio vs CTA was higher than the proposed willingness-to-pay threshold. Invasive strategies were dominant in the high pretest probability setting. Sensitivity analysis showed that results were sensitive to costs of CTA, ECHO, and C-MRI. Coronary CT is cost-effective for the diagnosis of coronary artery disease and should be included in the Brazilian public health system. Stress ECHO has a similar performance and is an acceptable alternative for most patients, but invasive strategies should be reserved for patients at high risk. © 2016 Wiley Periodicals, Inc.

  19. Long-term urethral catheterisation.

    Science.gov (United States)

    Turner, Bruce; Dickens, Nicola

    This article discusses long-term urethral catheterisation, focusing on the relevant anatomy and physiology, indications for the procedure, catheter selection and catheter care. It is important that nurses have a good working knowledge of long-term catheterisation as the need for this intervention will increase with the rise in chronic health conditions and the ageing population.

  20. Long-term decrease of atmospheric test 137Cs in the soil-prairie plant-milk pathway in southern Chile

    International Nuclear Information System (INIS)

    Schuller, P.; Ellies, A.; Handl, J.

    1998-01-01

    The time dependency of nuclear test 137 Cs in soil, prairie plants, and milk was observed on pastures of seven dairy farms in the 10th Region, Chile, from 1982 to 1997, without any appreciable deposition of radioactive fallout after 1983. Whereas the 137 Cs concentration in the soil decreased at a rate close to that of the radionuclide's physical decay during the whole observation period, the rate of decrease of the 137 Cs concentration in the prairie plants and in the milk, having been very rapid between 1982--1990, became slower between 1991--1997. The effective half-lives of the concentration in plants were found to be 5.6 y and 12 y during the first and second observation periods, respectively. Similar half-lives of 5.5 y and 13 y were found for the concentration decline in milk during each period. These data clearly demonstrate a reduction in the long-term decrease of the 137 Cs plant uptake, and consequently in the decrease of the 137 Cs concentration in milk, resulting from a decline of 137 Cs availability for prairie plants in the Hapludand soils over the whole 15-y observation period

  1. Arsenic Removal from Groundwater by Solar Driven Inline-Electrolytic Induced Co-Precipitation and Filtration—A Long Term Field Test Conducted in West Bengal

    Science.gov (United States)

    Malakar, Pradyut; Jana, Bana Bihari; Benz, Florian; Goldmaier, Alexander; Feistel, Ulrike; Jana, Joydev; Lahiri, Susmita; Alvarez, Juan Antonio

    2017-01-01

    Arsenic contamination in drinking water resources is of major concern in the Ganga delta plains of West Bengal in India and Bangladesh. Here, several laboratory and field studies on arsenic removal from drinking water resources were conducted in the past and the application of strong-oxidant-induced co-precipitation of arsenic on iron hydroxides is still considered as the most promising mechanism. This paper suggests an autonomous, solar driven arsenic removal setting and presents the findings of a long term field test conducted in West Bengal. The system applies an inline-electrolytic cell for in situ chlorine production using the natural chloride content of the water and by that substituting the external dosing of strong oxidants. Co-precipitation of As(V) occurs on freshly formed iron hydroxide, which is removed by Manganese Greensand Plus® filtration. The test was conducted for ten months under changing source water conditions considering arsenic (187 ± 45 µg/L), iron (5.5 ± 0.8 mg/L), manganese (1.5 ± 0.4 mg/L), phosphate (2.4 ± 1.3 mg/L) and ammonium (1.4 ± 0.5 mg/L) concentrations. Depending on the system setting removal rates of 94% for arsenic (10 ± 4 µg/L), >99% for iron (0.03 ± 0.03 mg/L), 96% for manganese (0.06 ± 0.05 mg/L), 72% for phosphate (0.7 ± 0.3 mg/L) and 84% for ammonium (0.18 ± 0.12 mg/L) were achieved—without the addition of any chemicals/adsorbents. Loading densities of arsenic on iron hydroxides averaged to 31 µgAs/mgFe. As the test was performed under field conditions and the here proposed removal mechanisms work fully autonomously, it poses a technically feasible treatment alternative, especially for rural areas. PMID:28974053

  2. Arsenic Removal from Groundwater by Solar Driven Inline-Electrolytic Induced Co-Precipitation and Filtration-A Long Term Field Test Conducted in West Bengal.

    Science.gov (United States)

    Otter, Philipp; Malakar, Pradyut; Jana, Bana Bihari; Grischek, Thomas; Benz, Florian; Goldmaier, Alexander; Feistel, Ulrike; Jana, Joydev; Lahiri, Susmita; Alvarez, Juan Antonio

    2017-10-02

    Arsenic contamination in drinking water resources is of major concern in the Ganga delta plains of West Bengal in India and Bangladesh. Here, several laboratory and field studies on arsenic removal from drinking water resources were conducted in the past and the application of strong-oxidant-induced co-precipitation of arsenic on iron hydroxides is still considered as the most promising mechanism. This paper suggests an autonomous, solar driven arsenic removal setting and presents the findings of a long term field test conducted in West Bengal. The system applies an inline-electrolytic cell for in situ chlorine production using the natural chloride content of the water and by that substituting the external dosing of strong oxidants. Co-precipitation of As(V) occurs on freshly formed iron hydroxide, which is removed by Manganese Greensand Plus ® filtration. The test was conducted for ten months under changing source water conditions considering arsenic (187 ± 45 µg/L), iron (5.5 ± 0.8 mg/L), manganese (1.5 ± 0.4 mg/L), phosphate (2.4 ± 1.3 mg/L) and ammonium (1.4 ± 0.5 mg/L) concentrations. Depending on the system setting removal rates of 94% for arsenic (10 ± 4 µg/L), >99% for iron (0.03 ± 0.03 mg/L), 96% for manganese (0.06 ± 0.05 mg/L), 72% for phosphate (0.7 ± 0.3 mg/L) and 84% for ammonium (0.18 ± 0.12 mg/L) were achieved-without the addition of any chemicals/adsorbents. Loading densities of arsenic on iron hydroxides averaged to 31 µgAs/mgFe. As the test was performed under field conditions and the here proposed removal mechanisms work fully autonomously, it poses a technically feasible treatment alternative, especially for rural areas.

  3. Long-Term and Short-Term Effects of Hemodialysis on Liver Function Evaluated Using the Galactose Single-Point Test

    Directory of Open Access Journals (Sweden)

    Yi-Chou Hou

    2014-01-01

    Full Text Available Aim. The galactose single-point (GSP test assesses functioning liver mass by measuring the galactose concentration in the blood 1 hour after its administration. The purpose of this study was to investigate the impact of hemodialysis (HD on short-term and long-term liver function by use of GSP test. Methods. Seventy-four patients on maintenance HD (46 males and 28 females, 60.38 ± 11.86 years with a mean time on HD of 60.77 ± 48.31 months were studied. The GSP values were compared in two groups: (1 before and after single session HD, and (2 after one year of maintenance HD. Results. Among the 74 HD patient, only the post-HD Cr levels and years on dialysis were significantly correlated with GSP values (r=0.280, P<0.05 and r=-0.240, P<0.05, resp.. 14 of 74 patients were selected for GSP evaluation before and after a single HD session, and the hepatic clearance of galactose was similar (pre-HD 410 ± 254 g/mL, post-HD 439 ± 298 g/mL, P=0.49. GSP values decreased from 420.20 ± 175.26 g/mL to 383.40 ± 153.97 g/mL after 1 year maintenance HD in other 15 patients (mean difference: 19.00 ± 37.66 g/mL, P<0.05. Conclusions. Patients on maintenance HD for several years may experience improvement of their liver function. However, a single HD session does not affect liver function significantly as assessed by the GSP test. Since the metabolism of galactose is dependent on liver blood flow and hepatic functional mass, further studies are needed.

  4. Factors to be Considered in Long-Term Monitoring of a Former Nuclear Test Site in a Geophysically Active and Water-rich Environment

    Science.gov (United States)

    Eichelberger, J.; Hill, G.; Patrick, M.; Freymueller, J.; Barnes, D.; Kelley, J.; Layer, P.

    2001-12-01

    The US Department of Energy (USDOE) is currently undertaking an ambitious program of environmental remediation of the surface of Amchitka Island in the western Aleutians, where three underground nuclear tests were conducted during 1963-1971. Among these tests was Cannikin, at approximately 5 megatons the largest nuclear device ever exploded underground by the United States and equivalent in seismic energy release to a magnitude 7 earthquake. The blast caused about 1 m of uplift of the Bering Sea coastline in the 3-km-wide fault-bounded block within which it was detonated. The impending final transfer of stewardship of this area to the US Fish and Wildlife Service as part of the Alaska Maritime National Wildlife Refuge raises anew the question of the potential for transport of radionuclides from the shot cavity, located at 1791 m depth in mafic laharic breccias, into the accessible environment. In particular, there is concern about whether such contaminants could become concentrated in the marine food chain that is used for subsistence by Alaskan Natives (and by the broader international community through the North Pacific and Bering Fisheries). Both possible transport pathways in the form of faults and transport medium in the form of abundant water are present. Since the pre-plate tectonics paradigm days of active testing, the scientific community's understanding of the tectonic context of the Aleutian Islands has grown tremendously. Recently, the first direct measurements of motion within the arc have been made. How this new understanding should guide plans for long-term monitoring of the site is an important question. Convergence due to subduction of the North Pacific plate beneath North America ranges from near-normal at the Alaska Peninsula and eastern Aleutian islands to highly oblique in the west. Amchitka itself can be seen as a subaerial portion of a 200-km-long Rat Island arc crest segment. This fragment has torn from the Andreanof Islands to the east at

  5. Pumping Test Determination of Unsaturated Aquifer Properties

    Science.gov (United States)

    Mishra, P. K.; Neuman, S. P.

    2008-12-01

    Tartakovsky and Neuman [2007] presented a new analytical solution for flow to a partially penetrating well pumping at a constant rate from a compressible unconfined aquifer considering the unsaturated zone. In their solution three-dimensional, axially symmetric unsaturated flow is described by a linearized version of Richards' equation in which both hydraulic conductivity and water content vary exponentially with incremental capillary pressure head relative to its air entry value, the latter defining the interface between the saturated and unsaturated zones. Both exponential functions are characterized by a common exponent k having the dimension of inverse length, or equivalently a dimensionless exponent kd=kb where b is initial saturated thickness. The authors used their solution to analyze drawdown data from a pumping test conducted by Moench et al. [2001] in a Glacial Outwash Deposit at Cape Cod, Massachusetts. Their analysis yielded estimates of horizontal and vertical saturated hydraulic conductivities, specific storage, specific yield and k . Recognizing that hydraulic conductivity and water content seldom vary identically with incremental capillary pressure head, as assumed by Tartakovsky and Neuman [2007], we note that k is at best an effective rather than a directly measurable soil parameter. We therefore ask to what extent does interpretation of a pumping test based on the Tartakovsky-Neuman solution allow estimating aquifer unsaturated parameters as described by more common constitutive water retention and relative hydraulic conductivity models such as those of Brooks and Corey [1964] or van Genuchten [1980] and Mualem [1976a]? We address this question by showing how may be used to estimate the capillary air entry pressure head k and the parameters of such constitutive models directly, without a need for inverse unsaturated numerical simulations of the kind described by Moench [2003]. To assess the validity of such direct estimates we use maximum

  6. Injection grout for deep repositories. Subproject 1: LowpH cementitious grout for larger fractures, leach testing of grout mixes and evaluation of the long-term safety

    International Nuclear Information System (INIS)

    Vuorinen, U.; Lehikoinen, J.; Imoto, Harutake; Yamamoto, Takeshi; Cruz Alonso, M.

    2005-10-01

    Constructing an underground disposal facility for spent nuclear fuel deep in bedrock requires lowpH cement-based injection grout, because assured data of the extent of a possible high-pH plume in saturated bedrock conditions is lacking. In this work low-pH grout mixes of new design were subjected to leach testing. Before chosen to leach testing the grout mixes had to fulfil certain technical requirements. Leach testing was performed in order to establish that the pH requirement (≤11) set for the leachates was met. For comparison reasons also one conventionally used cement based grout material was included in the tests. Two kinds of lowpH grout cement mixes were tested; mixes with added blast furnace slag (4 mixes) or added silica (6 mixes). All the mixes were not completely tested according to the test plan, because for some mixes during leach testing factors detrimental to the long-term safety of a repository were observed, e.g. too high pH or leached sulphide, which is harmful for copper. Leach testing of the grout mixes was performed in a glove-box (N 2 atmosphere) in order to avoid the interference of atmospheric CO 2 on the alkaline leachates. Two simulated groundwater solutions, saline OL-SO and fresh ALL-MR, were used as leachates. Two leach tests were applied; equilibrium and diffusion tests. In the equilibrium test at each measuring point only a part of the leachate was exchanged, whereas in the diffusion test the entire leachate was exchanged. The pH value of each leachate sample was measured, but total alkalinity was determined only for some leachates. Na, K, Ca, Mg, Al, Fe, Si, SO 4 2- , S TOT , and Cl were analysed in the leach solutions collected in the diffusion test of four grout mixes chosen. Also the corresponding solid specimens were analysed (SEM, XRD, EPMA, MIP, TG) in Japan. A few grout pore fluid pH values were measured in Spain, as well. The simplified thermodynamic model calculations were successful in qualitatively reproducing the

  7. Decision-analytic modeling to evaluate the long-term effectiveness and cost-effectiveness of HPV-DNA testing in primary cervical cancer screening in Germany

    Directory of Open Access Journals (Sweden)

    Krämer, Alexander

    2010-01-01

    Full Text Available Background: Persistent infections with high-risk types of human papillomavirus (HPV are associated with the development of cervical neoplasia. Compared to cytology HPV testing is more sensitive in detecting high-grade cervical cancer precursors, but with lower specificity. HPV based primary screening for cervical cancer is currently discussed in Germany. Decisions should be based on a systematic evaluation of the long-term effectiveness and cost-effectiveness of HPV based primary screening. Research questions: What is the long-term clinical effectiveness (reduction in lifetime risk of cervical cancer and death due to cervical cancer, life years gained of HPV testing and what is the cost-effectiveness in Euro per life year gained (LYG of including HPV testing in primary cervical cancer screening in the German health care context? How can the screening program be improved with respect to test combination, age at start and end of screening and screening interval and which recommendations should be made for the German health care context? Methods: A previously published and validated decision-analytic model for the German health care context was extended and adapted to the natural history of HPV infection and cervical cancer in order to evaluate different screening strategies that differ by screening interval, and tests, including cytology alone, HPV testing alone or in combination with cytology, and HPV testing with cytology triage for HPV-positive women. German clinical, epidemiological and economic data were used. In the absence of individual data, screening adherence was modelled independently from screening history. Test accuracy data were retrieved from international meta-analyses. Predicted outcomes included reduction in lifetime-risk for cervical cancer cases and deaths, life expectancy, lifetime costs, and discounted incremental cost-effectiveness ratios (ICER. The perspective of the third party payer and 3% annual discount rate were

  8. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  9. Pump testing - Comparison of factory vs. field test of centrifugal pumps

    International Nuclear Information System (INIS)

    Fehlau, R.

    1992-01-01

    Testing of pumps in situ, i.e., as installed in a system, will typically yield somewhat different performance results from the original manufacturer's factory test. This paper discusses some of the reasons for these variations. It shows that the factory test curves can be used for evaluation of initial acceptance tests but not for reference in normal inservice testing (IST). This is the basis for reference values used in American Society of Mechanical Engineers (ASME) Section 11 specifications and the revised ASME Code 1990

  10. Gentilly-2 NPP - Concrete aging effects on long term pre-stress losses and propagation of concrete cracking due to pressure testing

    International Nuclear Information System (INIS)

    Gocevski, V.

    2011-01-01

    This paper presents the results of the study intended to evaluate the post-tension long term losses and propagation of cracks in the envelope of Gentilly-2 Nuclear Power Plant reactor building. The numerical simulation of concrete, that takes into account elastic as well as inelastic strains due to loading, shrinkage strains due to drying or cooling and inelastic strains from alkali-aggregate reaction (AAR) related swelling, is explained. The simultaneous contribution of AAR, shrinkage and creep, are simulated using an enhanced elastic-plastic constitutive relation. The nonlinear relations are validated by comparing the numerically calculated strains with strain measurements from the extensometers placed in the concrete during the construction of the envelope. The post-tension losses/gains are evaluated for the vertical as well as horizontal cables. Also included is the result of pull-out test conducted on sample beam cast at the time of the reactor building construction with the same concrete mix, post-tension cable and force. Structural behaviour of the beam is simulated over the same period of time as the reactor building envelope. The test results are used also to calibrate the numerical model. The paper also includes discussion of the results obtained from the simulation of a standard internal high pressure test (145 kPa). The behavior of the reactor building envelope, prior to applied pressure, during the test and for the period of several months after the testing was simulated using an advanced numerical model and the results (strains) were compared with measured values. It was found that this method may be used as an approximate procedure for evaluation of post-tension losses/gains and assessment of propagation of cracking visible on the outside surfaces of the confinement building. In addition, a discussion of the negative effect of high post-tension on the air tightness of the confinement building of Gentilly-2. The comparison is made between the post

  11. Gentilly-2 NPP - Concrete aging effects on long term pre-stress losses and propagation of concrete cracking due to pressure testing

    Energy Technology Data Exchange (ETDEWEB)

    Gocevski, V. [Hydro-Quebe (Canada)

    2011-07-01

    This paper presents the results of the study intended to evaluate the post-tension long term losses and propagation of cracks in the envelope of Gentilly-2 Nuclear Power Plant reactor building. The numerical simulation of concrete, that takes into account elastic as well as inelastic strains due to loading, shrinkage strains due to drying or cooling and inelastic strains from alkali-aggregate reaction (AAR) related swelling, is explained. The simultaneous contribution of AAR, shrinkage and creep, are simulated using an enhanced elastic-plastic constitutive relation. The nonlinear relations are validated by comparing the numerically calculated strains with strain measurements from the extensometers placed in the concrete during the construction of the envelope. The post-tension losses/gains are evaluated for the vertical as well as horizontal cables. Also included is the result of pull-out test conducted on sample beam cast at the time of the reactor building construction with the same concrete mix, post-tension cable and force. Structural behaviour of the beam is simulated over the same period of time as the reactor building envelope. The test results are used also to calibrate the numerical model. The paper also includes discussion of the results obtained from the simulation of a standard internal high pressure test (145 kPa). The behavior of the reactor building envelope, prior to applied pressure, during the test and for the period of several months after the testing was simulated using an advanced numerical model and the results (strains) were compared with measured values. It was found that this method may be used as an approximate procedure for evaluation of post-tension losses/gains and assessment of propagation of cracking visible on the outside surfaces of the confinement building. In addition, a discussion of the negative effect of high post-tension on the air tightness of the confinement building of Gentilly-2. The comparison is made between the post

  12. Graph Theoretical Analysis of Functional Brain Networks: Test-Retest Evaluation on Short- and Long-Term Resting-State Functional MRI Data

    Science.gov (United States)

    Wang, Jin-Hui; Zuo, Xi-Nian; Gohel, Suril; Milham, Michael P.; Biswal, Bharat B.; He, Yong

    2011-01-01

    Graph-based computational network analysis has proven a powerful tool to quantitatively characterize functional architectures of the brain. However, the test-retest (TRT) reliability of graph metrics of functional networks has not been systematically examined. Here, we investigated TRT reliability of topological metrics of functional brain networks derived from resting-state functional magnetic resonance imaging data. Specifically, we evaluated both short-term (5 months apart) TRT reliability for 12 global and 6 local nodal network metrics. We found that reliability of global network metrics was overall low, threshold-sensitive and dependent on several factors of scanning time interval (TI, long-term>short-term), network membership (NM, networks excluding negative correlations>networks including negative correlations) and network type (NT, binarized networks>weighted networks). The dependence was modulated by another factor of node definition (ND) strategy. The local nodal reliability exhibited large variability across nodal metrics and a spatially heterogeneous distribution. Nodal degree was the most reliable metric and varied the least across the factors above. Hub regions in association and limbic/paralimbic cortices showed moderate TRT reliability. Importantly, nodal reliability was robust to above-mentioned four factors. Simulation analysis revealed that global network metrics were extremely sensitive (but varying degrees) to noise in functional connectivity and weighted networks generated numerically more reliable results in compared with binarized networks. For nodal network metrics, they showed high resistance to noise in functional connectivity and no NT related differences were found in the resistance. These findings provide important implications on how to choose reliable analytical schemes and network metrics of interest. PMID:21818285

  13. Long term study of mechanical

    Directory of Open Access Journals (Sweden)

    Ahmed M. Diab

    2016-06-01

    Full Text Available In this study, properties of limestone cement concrete containing different replacement levels of limestone powder were examined. It includes 0%, 5%, 10%, 15%, 20% and 25% of limestone powder as a partial replacement of cement. Silica fume was added incorporated with limestone powder in some mixes to enhance the concrete properties. Compressive strength, splitting tensile strength and modulus of elasticity were determined. Also, durability of limestone cement concrete with different C3A contents was examined. The weight loss, length change and cube compressive strength loss were measured for concrete attacked by 5% sodium sulfate using an accelerated test up to 525 days age. The corrosion resistance was measured through accelerated corrosion test using first crack time, cracking width and steel reinforcement weight loss. Consequently, for short and long term, the use of limestone up to 10% had not a significant reduction in concrete properties. It is not recommended to use blended limestone cement in case of sulfate attack. The use of limestone cement containing up to 25% limestone has insignificant effect on corrosion resistance before cracking.

  14. Long-term corrosion studies

    International Nuclear Information System (INIS)

    Gdowski, G.

    1998-01-01

    The scope of this activity is to assess the long-term corrosion properties of metallic materials under consideration for fabricating waste package containers. Three classes of metals are to be assessed: corrosion resistant, intermediate corrosion resistant, and corrosion allowance. Corrosion properties to be evaluated are general, pitting and crevice corrosion, stress-corrosion cracking, and galvanic corrosion. The performance of these materials will be investigated under conditions that are considered relevant to the potential emplacement site. Testing in four aqueous solutions, and vapor phases above them, and at two temperatures are planned for this activity. (The environmental conditions, test metals, and matrix are described in detail in Section 3.0.) The purpose and objective of this activity is to obtain the kinetic and mechanistic information on degradation of metallic alloys currently being considered for waste package containers. This information will be used to provide assistance to (1) waste package design (metal barrier selection) (E-20-90 to E-20-92), (2) waste package performance assessment activities (SIP-PA-2), (3) model development (E-20-75 to E-20-89). and (4) repository license application

  15. LH2 pump component development testing in the electric pump room at test cell C inducer no. 1

    Science.gov (United States)

    Andrews, F. X.; Brunner, J. J.; Kirk, K. G.; Mathews, J. P.; Nishioka, T.

    1972-01-01

    The characteristics of a turbine pump for use with the nuclear engine for rocket vehicles are discussed. It was determined that the pump will be a two stage centrifugal pump with both stages having backswept impellers and an inducer upstream of the first stage impeller. The test program provided demonstration of the ability of the selected design to meet the imposed requirements.

  16. Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

    Energy Technology Data Exchange (ETDEWEB)

    Sjostrom, Sharon; Amrhein, Jerry

    2009-04-30

    The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The

  17. Testing resiliency of hydrologic dynamics of a paired forested watershed after a hurricane in Atlantic coastal plain using long-term data

    Science.gov (United States)

    Devendra Amatya; Herbert Ssegane; Charles Andy Harrison; Carl Trettin

    2016-01-01

    Hurricanes are infrequent but influential disruptors of ecosystem processes, including streamflow and evapotranspiration dynamics in the southeastern Atlantic and Gulf coasts. However, literature on hurricane effects on long-term streamflow dynamics is lacking in this highly urbanizing region characterized by a poorly drained low-gradient forested landscape.

  18. Nuclear energy - Standard method for testing the long-term alpha irradiation stability of matrices for solidification of high-level radioactive waste. 2. ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This International Standard specifies a method designed to check the long-term stability of a solid to alpha disintegration by detection of all modifications in the properties of an irradiated sample. The material favoured hitherto is a borosilicate glass, but possible alternatives include: ceramics or glass-ceramics, and other glass compositions

  19. Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    C. Jean Bustard; Charles Lindsey; Paul Brignac

    2006-05-01

    This document provides a summary of the full-scale demonstration efforts involved in the project ''Field Test Program for Long-Term Operation of a COHPAC{reg_sign} System for Removing Mercury from Coal-Fired Flue Gas''. The project took place at Alabama Power's Plant Gaston Unit 3 and involved the injection of sorbent between an existing particulate collector (hot-side electrostatic precipitators) and a COHPAC{reg_sign} fabric filter (baghouse) downstream. Although the COHPAC{reg_sign} baghouse was designed originally for polishing the flue gas, when activated carbon injection was added, the test was actually evaluating the EPRI TOXECON{reg_sign} configuration. The results from the baseline tests with no carbon injection showed that the cleaning frequency in the COHPAC{reg_sign} unit was much higher than expected, and was above the target maximum cleaning frequency of 1.5 pulses/bag/hour (p/b/h), which was used during the Phase I test in 2001. There were times when the baghouse was cleaning continuously at 4.4 p/b/h. In the 2001 tests, there was virtually no mercury removal at baseline conditions. In this second round of tests, mercury removal varied between 0 and 90%, and was dependent on inlet mass loading. There was a much higher amount of ash exiting the electrostatic precipitators (ESP), creating an inlet loading greater than the design conditions for the COHPAC{reg_sign} baghouse. Tests were performed to try to determine the cause of the high ash loading. The LOI of the ash in the 2001 baseline tests was 11%, while the second baseline tests showed an LOI of 17.4%. The LOI is an indication of the carbon content in the ash, which can affect the native mercury uptake, and can also adversely affect the performance of ESPs, allowing more ash particles to escape the unit. To overcome this, an injection scheme was implemented that balanced the need to decrease carbon injection during times when inlet loading to the baghouse was high and

  20. Seismic fragility capacity of equipment--horizontal shaft pump test

    International Nuclear Information System (INIS)

    Iijima, T.; Abe, H.; Suzuki, K.

    2005-01-01

    The current seismic fragility capacity of horizontal shaft pump is 1.6 x 9.8 m/s 2 (1.6 g), which was decided from previous vibration tests and we believe that it must have sufficient margin. The purpose of fragility capacity test is to obtain realistic seismic fragility capacity of horizontal shaft pump by vibration tests. Reactor Building Closed Cooling Water (RCW) Pump was tested as a typical horizontal shaft pump, and then bearings and liner rings were tested as important parts to evaluate critical acceleration and dispersion. Regarding RCW pump test, no damage was found, though maximum input acceleration level was 6 x 9.8 m/s 2 (6 g). Some kinds of bearings and liner rings were tested on the element test. Input load was based on seismic motion which was same with the RCW pump test, and maximum load was equivalent to over 20 times of design seismic acceleration. There was not significant damage that caused emergency stop of pump but degradation of surface roughness was found on some kinds of bearings. It would cause reduction of pump life, but such damage on bearings occurred under large seismic load condition that was equivalent to over 10 to 20 g force. Test results show that realistic fragility capacity of horizontal shaft pump would be at least four times as higher as current value which has been used for our seismic PSA. (authors)

  1. Arsenic Removal from Groundwater by Solar Driven Inline-Electrolytic Induced Co-Precipitation and Filtration—A Long Term Field Test Conducted in West Bengal

    Directory of Open Access Journals (Sweden)

    Philipp Otter

    2017-10-01

    Full Text Available Arsenic contamination in drinking water resources is of major concern in the Ganga delta plains of West Bengal in India and Bangladesh. Here, several laboratory and field studies on arsenic removal from drinking water resources were conducted in the past and the application of strong-oxidant-induced co-precipitation of arsenic on iron hydroxides is still considered as the most promising mechanism. This paper suggests an autonomous, solar driven arsenic removal setting and presents the findings of a long term field test conducted in West Bengal. The system applies an inline-electrolytic cell for in situ chlorine production using the natural chloride content of the water and by that substituting the external dosing of strong oxidants. Co-precipitation of As(V occurs on freshly formed iron hydroxide, which is removed by Manganese Greensand Plus® filtration. The test was conducted for ten months under changing source water conditions considering arsenic (187 ± 45 µg/L, iron (5.5 ± 0.8 mg/L, manganese (1.5 ± 0.4 mg/L, phosphate (2.4 ± 1.3 mg/L and ammonium (1.4 ± 0.5 mg/L concentrations. Depending on the system setting removal rates of 94% for arsenic (10 ± 4 µg/L, >99% for iron (0.03 ± 0.03 mg/L, 96% for manganese (0.06 ± 0.05 mg/L, 72% for phosphate (0.7 ± 0.3 mg/L and 84% for ammonium (0.18 ± 0.12 mg/L were achieved—without the addition of any chemicals/adsorbents. Loading densities of arsenic on iron hydroxides averaged to 31 µgAs/mgFe. As the test was performed under field conditions and the here proposed removal mechanisms work fully autonomously, it poses a technically feasible treatment alternative, especially for rural areas.

  2. Tests of cooling water pumps at Dukovany nuclear power plant

    International Nuclear Information System (INIS)

    Travnicek, J.

    1986-01-01

    Tests were performed to examine the operating conditions of the 1600 BQDV cooling pumps of the main coolant circuit of unit 1 of the Dukovany nuclear power plant. For the pumps, the performance was tested in the permissible operating range, points were measured below this range and the guaranteed operating point was verified. Pump efficiency was calculated from the measured values. The discussion of the measurement of parameters has not yet been finished because the obtained values of the amount delivered and thus of the pump efficiency were not up to expectation in all detail. It was also found that for obtaining the guaranteed flow the pump impeller had to be opened to 5deg -5.5deg instead of the declared 3deg. Also tested were pump transients, including the start of the pump, its stop, the operation and failure of one of the two pumps. In these tests, pressures were also measured at the inlet and the outlet of the inner part of the TG 11 turbine condenser. It was shown that the time course and the pressure course of the processes were acceptable. In addition to these tests, pressure losses in the condenser and the cooling water flow through the feed pump electromotor cooler wre tested for the case of a failure of one of the two pumps. (E.S.)

  3. [Long-term psychiatric hospitalizations].

    Science.gov (United States)

    Plancke, L; Amariei, A

    2017-02-01

    Long-term hospitalizations in psychiatry raise the question of desocialisation of the patients and the inherent costs. Individual indicators were extracted from a medical administrative database containing full-time psychiatric hospitalizations for the period 2011-2013 of people over 16 years old living in the French region of Nord-Pas-de-Calais. We calculated the proportion of people who had experienced a hospitalization with a duration of 292 days or more during the study period. A bivariate analysis was conducted, then ecological data (level of health-care offer, the deprivation index and the size of the municipalities of residence) were included into a multilevel regression model in order to identify the factors significantly related to variability of long-term hospitalization rates. Among hospitalized individuals in psychiatry, 2.6% had had at least one hospitalization of 292 days or more during the observation period; the number of days in long-term hospitalization represented 22.5% of the total of days of full-time hospitalization in psychiatry. The bivariate analysis revealed that seniority in the psychiatric system was strongly correlated with long hospitalization rates. In the multivariate analysis, the individual indicators the most related to an increased risk of long-term hospitalization were: total lack of autonomy (OR=9.0; 95% CI: 6.7-12.2; P<001); diagnoses of psychological development disorders (OR=9.7; CI95%: 4.5-20.6; P<.001); mental retardation (OR=4.5; CI95%: 2.5-8.2; P<.001): schizophrenia (OR=3.0; CI95%: 1.7-5.2; P<.001); compulsory hospitalization (OR=1.7; CI95%: 1.4-2.1; P<.001); having experienced therapeutic isolation (OR=1.8; CI95%: 1.5-2.1; P<.001). Variations of long-term hospitalization rates depending on the type of establishment were very high, but the density of hospital beds or intensity of ambulatory activity services were not significantly linked to long-term hospitalization. The inhabitants of small urban units had

  4. Long-term dependence in exchange rates

    Directory of Open Access Journals (Sweden)

    A. Karytinos

    2000-01-01

    Full Text Available The extent to which exchange rates of four major currencies against the Greek Drachma exhibit long-term dependence is investigated using a R/S analysis testing framework. We show that both classic R/S analysis and the modified R/S statistic if enhanced by bootstrapping techniques can be proven very reliable tools to this end. Our findings support persistence and long-term dependence with non-periodic cycles for the Deutsche Mark and the French Franc series. In addition a noisy chaos explanation is favored over fractional Brownian motion. On the contrary, the US Dollar and British Pound were found to exhibit a much more random behavior and lack of any long-term structure.

  5. Reactor primary pumps dynamic balancing test

    International Nuclear Information System (INIS)

    Lu Qunxian

    2002-01-01

    Reactor primary Pump is the important equipment in the primary circuit, its working quality would directly influence the safety and operation of nuclear power plant. The author describes that the primary pump vibration status, vibration fault diagnosis and dynamic balancing process on site have been performed since commercial operation of DA YA BAY Nuclear Power plant

  6. Reactor coolant pump testing using motor current signatures analysis

    Energy Technology Data Exchange (ETDEWEB)

    Burstein, N.; Bellamy, J.

    1996-12-01

    This paper describes reactor coolant pump motor testing carried out at Florida Power Corporation`s Crystal River plant using Framatome Technologies` new EMPATH (Electric Motor Performance Analysis and Trending Hardware) system. EMPATH{trademark} uses an improved form of Motor Current Signature Analysis (MCSA), technology, originally developed at Oak Ridge National Laboratories, for detecting deterioration in the rotors of AC induction motors. Motor Current Signature Analysis (MCSA) is a monitoring tool for motor driven equipment that provides a non-intrusive means for detecting the presence of mechanical and electrical abnormalities in the motor and the driven equipment. The base technology was developed at the Oak Ridge National Laboratory as a means for determining the affects of aging and service wear specifically on motor-operated valves used in nuclear power plant safety systems, but it is applicable to a broad range of electric machinery. MCSA is based on the recognition that an electric motor (ac or dc) driving a mechanical load acts as an efficient and permanently available transducer by sensing mechanical load variations, large and small, long-term and rapid, and converting them into variations in the induced current generated in the motor windings. The motor current variations, resulting from changes in load caused by gears, pulleys, friction, bearings, and other conditions that may change over the life of the motor, are carried by the electrical cables powering the motor and are extracted at any convenient location along the motor lead. These variations modulate the 60 Hz carrier frequency and appear as sidebands in the spectral plot.

  7. Investigation of two widely used nanomaterials (TiO{sub 2}, Ag) for ecotoxicological long-term effects. Adaption of test guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Schaefers, Christoph [Fraunhofer-Institut fuer Molekularbiologie und Angewandte Oekologie (IME), Schmallenberg (Germany); Weil, Mirco [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2013-03-15

    The nanoparticulate titanium dioxide NM-105 was investigated with Lumbriculus variegatus in a sediment- water system according to OECD TG 225. Test media were prepared by dilution of NM-105-suspensions with the sediment-overlying water. Nominal test concentrations (confirmed by chemical analysis of Ti conc. in test media) were 15; 23; 39; 63 and 100 mg NM-105/L. No adverse effects on reproduction or biomass of the worms were observed. The NOEC {>=} 100 mg/L was confirmed in a second test with 100 mg NM-105/L. At test end, Ti conc. in worms were similar in all treatments. Additionally, NM-105 was investigated in OECD TG 226 tests with the predatory mite Hypoaspis aculeifer. Test substrates were prepared by mixing the solid powder into artificial soil (test conc. {>=} 10mg/kg) or application of NM-105-suspensions ({<=} 10mg/kg). For 10 mg/kg, no influence of the application method on the endpoints was observed. No significant effect of the treatments 1; 10; 100; 1000 mg NM-105/kg artificial soil (dw) was detected in the 1{sup st} definitive test, the 2{sup nd} test at 1 and 1000 mg NM-105/kg showed significantly lower numbers of juvenile mites compared to the control in both treatments due to higher statistical power of the doubled number of replicates. For the standard design, which was proven to be applicable to the testing of nanomaterials, the NOEC was {>=} 1000 mg NM-105/kg. The nanoparticulate silver NM-300 K was investigated in two fish early life stage toxicity tests (OECD TG 210) with Danio rerio in a 250 L static system. The NM-300 K dispersion (1:10) was slightly diluted, ultra-sonificated and directly applied to the test vessels. The water in all test aquaria was constantly moved by four pumps each for homogeneous distribution and minimized sedimentation. Every 7 days, the test medium was exchanged. The nominal test concentrations were 12.5; 25; 50; 100 and 200 {mu}g Ag/L in the 1{sup st} test and 12.5; 50; 100 {mu}g/L in the 2{sup nd} test. Chemical

  8. The Development of a Long-Term, Continually Updated Global Solar Resource at 10 km Resolution: Preliminary Results From Test Processing and Continuing Plans

    Science.gov (United States)

    Stackhouse, P.; Perez, R.; Sengupta, M.; Knapp, K.; Cox, Stephen; Mikovitz, J. Colleen; Zhang, T.; Hemker, K.; Schlemmer, J.; Kivalov, S.

    2014-01-01

    Background: Considering the likelihood of global climatic weather pattern changes and the global competition for energy resources, there is an increasing need to provide improved and continuously updated global Earth surface solar resource information. Toward this end, a project was funded under the NASA Applied Science program involving the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC), National Renewable Energy Laboratory (NREL), the State University of New York/Albany (SUNY) and the NOAA National Climatic Data Center (NCDC) to provide NREL with a global long-term advanced global solar mapping production system for improved depiction of historical solar resources and variability and to provide a mechanism for continual updates of solar resource information. This new production system is made possible by the efforts of NOAA and NASA to completely reprocess the International Satellite Cloud Climatology Project (ISCCP) data set that provides satellite visible and infrared radiances together with retrieved cloud and surface properties on a 3-hourly basis beginning from July 1983. The old version of the ISCCP data provided this information for all the world TMs available geosynchronous satellite systems and NOAA TMs AVHRR data sets at a 30 km effective resolution. This new version aims to provide a new and improved satellite calibration at an effective 10 km resolution. Thus, working with SUNY, NASA will develop and test an improved production system that will enable NREL to continually update the Earth TM solar resource. Objective and Methods: In this presentation, we provide a general overview of this project together with samples of the new solar irradiance mapped data products and comparisons to surface measurements at various locations across the world. An assessment of the solar resource values relative to calibration uncertainty and assumptions are presented. Errors resulting assumptions in snow cover and background aerosol

  9. Effect of irradiation and chemical composition on deformation and fracture of steel of OH16N15 type during long-term test

    International Nuclear Information System (INIS)

    Averin, S.A.; Deniskin, Yu.S.; Shushlebin, V.V.; Panchenko, V.L.

    1992-01-01

    Thermal and radiation creep, as well as long-term strength of an austenitic stainless steel were investigated as a function of sulphur content and niobium addition. Interrelation between the grain boundary sleep and the intergranular fracture, and an important role of the surface in the nucleation and propagation of crack were revealed by quantitative structural and fractographic studies. Irradiation and chemical composition were found to influence these processes

  10. Test report - 241-AN-274 Caustic Pump Control Building

    International Nuclear Information System (INIS)

    Paintner, G.P.

    1995-05-01

    This Acceptance Test Report documents the test results of test procedure WHC-SD-WM-ATP-135 'Acceptance Test Procedure for the 241-AN- 274 Caustic Pump Control Building.' The objective of the test was to verify that the 241-AN-274 Caustic Pump Control Building functions properly based on design specifications per applicable H-2-85573 drawings and associated ECN's. The objective of the test was met

  11. Timber joints under long-term loading

    DEFF Research Database (Denmark)

    Feldborg, T.; Johansen, M.

    This report describes tests and results from stiffness and strength testing of splice joints under long-term loading. During two years of loading the spicimens were exposed to cyclically changing relative humidity. After the loading period the specimens were short-term tested. The connectors were...... integral nail-plates and nailed steel and plywood gussets. The report is intended for designers and researchers in timber engineering....

  12. Subjective and objective peer approval evaluations and self-esteem development: A test of reciprocal, prospective, and long-term effects.

    Science.gov (United States)

    Gruenenfelder-Steiger, Andrea E; Harris, Michelle A; Fend, Helmut A

    2016-10-01

    A large body of literature suggests a clear, concurrent association between peer approval and self-esteem in adolescence. However, little empirical work exists on either the prospective or reciprocal relation between peer approval and self-esteem during this age period. Moreover, it is unclear from past research whether both subjectively perceived peer approval and objectively measured peer approval are related to subsequent self-esteem over time (and vice versa) and whether these paths have long-term associations into adulthood. Using data from a large longitudinal study that covers a time span of 2 decades, we examined reciprocal, prospective relations between self-esteem and peer approval during ages 12-16 in addition to long-term relations between these variables and later social constructs at age 35. Cross-lagged regression analyses revealed small but persistent effect sizes from both types of peer approval to subsequent self-esteem in adolescence, controlling for prior self-esteem. However, effects in the reverse direction were not confirmed. These findings support the notion that peer relationships serve an important function for later self-esteem, consistent with many theoretical tenets of the importance of peers for building a strong identity. Finally, we found long-term relations between adult social constructs and adolescent objective and subjective peer approval as well as self-esteem. Therefore, not only do peer relationships play a role in self-esteem development across adolescence, but they remain impactful throughout adulthood. In sum, the current findings highlight the lasting, yet small link between peer relationships and self-esteem development and call for investigations of further influential factors for self-esteem over time. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. The Performance test of Mechanical Sodium Pump with Water Environment

    International Nuclear Information System (INIS)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum; Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang

    2015-01-01

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  14. Decontamination tests in the recreational areas affected by the Chernobyl accident: efficiency of decontamination and long-term stability of the effects

    DEFF Research Database (Denmark)

    Ramzaev, V.; Barkovsky, A.; Mishine, A.

    2013-01-01

    in forest-grassland surroundings. The sites are located on the territory of the Bryansk region (Russia) at a distance of about 180 km north-east of the Chernobyl Nuclear Power Plant. Before intervention began, the inventory of 137Cs in soil was determined at a level of 1000 kBq m-2. The collaborative...... research project showed that use of simple countermeasures involving hand-tools and light machinery could reduce the external dose rate considerably, even though 10 years had passed since fallout of the Chernobyl radiocesium. The long-term monitoring of the recreational areas did not demonstrate...

  15. Impact of Total Ionizing Dose Radiation Testing and Long-Term Thermal Cycling on the Operation of CMF20120D Silicon Carbide Power MOSFET

    Science.gov (United States)

    Patterson, Richard L.; Scheidegger, Robert J.; Lauenstein, Jean-Marie; Casey, Megan; Scheick, Leif; Hammoud, Ahmad

    2013-01-01

    Power systems designed for use in NASA space missions are required to work reliably under harsh conditions including radiation, thermal cycling, and extreme temperature exposures. Silicon carbide devices show great promise for use in future power electronics systems, but information pertaining to performance of the devices in the space environment is very scarce. A silicon carbide N-channel enhancement-mode power MOSFET called the CMF20120 is of interest for use in space environments. Samples of the device were exposed to radiation followed by long-term thermal cycling to address their reliability for use in space applications. The results of the experimental work are presentd and discussed.

  16. The long-term follow up study of acute pancreatitis by means of pancreatic scintigraphy, secretin test and oral glucose tolerance test

    International Nuclear Information System (INIS)

    Satoh, Harukuni

    1975-01-01

    Morphologic and functional alternations of the pancreas following acute pancreatitis were studied in 29 patients. At the time of attack a diagnosis of acute pancreatitis had been confirmed by laparotomy in 27 cases, and by clinical picture and by serum amylase levels in 2 cases. The average duration of follow up was 56.3 months. Normal images were obtained in 17 of 29 cases. According to secretin tests, 4 of these had slight to moderately decreased exocrine function; the test were within normal limits. 12 cases with normal image had abnormal oral glucose tolerance curves similar to those fund in mild to moderate diabetes. 10 of the 12 cases with abnormal scintigrams showed decreased isotope uptake in all or part of the pancreas, while 2 showed no uptake at all. These changes were mast apparent in the tail of the pancreas. Ten of the 12 cases with abnormal images had some degree of decreased exocrine function. All 12 had the abnormal GTT curve of diabetes, 4 who had severe diabetes with markedly decreased exocrine function and poor image of the pancreas. In 4 cases the histopathological findings obtained at the time of laparotomy, were shown to be very consistent with the scintigraphic features. It was demonstrated by both scintigraphs and function tests that the alcoholic factor plays a very important role in the prognosis of acute pancreatitis. Acute pancreatitis resulted in chronic pancreatitis in 4 cases, (14 %) of the remaining 8 cases with abnormal scintigram, it is postulated that the inflamatory process subsided allowing time for cicatrical fibrosis to occur. Follow-up to trace and study of these alternations of the pancreas necessary in future. (Evans, J.)

  17. The long-term follow up study of acute pancreatitis by means of pancreatic scintigraphy, secretin test and oral glucose tolerance test

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, H [Tohoku Univ., Sendai (Japan). School of Medicine

    1975-03-01

    Morphologic and functional alternations of the pancreas following acute pancreatitis were studied in 29 patients. At the time of attack a diagnosis of acute pancreatitis had been confirmed by laparotomy in 27 cases, and by clinical picture and by serum amylase levels in 2 cases. The average duration of follow up was 56.3 months. Normal images were obtained in 17 of 29 cases. According to secretin tests, 4 of these had slight to moderately decreased exocrine function; the test were within normal limits. 12 cases with normal image had abnormal oral glucose tolerance curves similar to those fund in mild to moderate diabetes. 10 of the 12 cases with abnormal scintigrams showed decreased isotope uptake in all or part of the pancreas, while 2 showed no uptake at all. These changes were mast apparent in the tail of the pancreas. Ten of the 12 cases with abnormal images had some degree of decreased exocrine function. All 12 had the abnormal GTT curve of diabetes, 4 who had severe diabetes with markedly decreased exocrine function and poor image of the pancreas. In 4 cases the histopathological findings obtained at the time of laparotomy, were shown to be very consistent with the scintigraphic features. It was demonstrated by both scintigraphs and function tests that the alcoholic factor plays a very important role in the prognosis of acute pancreatitis. Acute pancreatitis resulted in chronic pancreatitis in 4 cases, (14 %) of the remaining 8 cases with abnormal scintigram, it is postulated that the inflamatory process subsided allowing time for cicatrical fibrosis to occur. Follow-up to trace and study of these alternations of the pancreas necessary in future.

  18. Development of a numerical pump testing framework.

    Science.gov (United States)

    Kaufmann, Tim A S; Gregory, Shaun D; Büsen, Martin R; Tansley, Geoff D; Steinseifer, Ulrich

    2014-09-01

    It has been shown that left ventricular assist devices (LVADs) increase the survival rate in end-stage heart failure patients. However, there is an ongoing demand for an increased quality of life, fewer adverse events, and more physiological devices. These challenges necessitate new approaches during the design process. In this study, computational fluid dynamics (CFD), lumped parameter (LP) modeling, mock circulatory loops (MCLs), and particle image velocimetry (PIV) are combined to develop a numerical Pump Testing Framework (nPTF) capable of analyzing local flow patterns and the systemic response of LVADs. The nPTF was created by connecting a CFD model of the aortic arch, including an LVAD outflow graft to an LP model of the circulatory system. Based on the same geometry, a three-dimensional silicone model was crafted using rapid prototyping and connected to an MCL. PIV studies of this setup were performed to validate the local flow fields (PIV) and the systemic response (MCL) of the nPTF. After validation, different outflow graft positions were compared using the nPTF. Both the numerical and the experimental setup were able to generate physiological responses by adjusting resistances and systemic compliance, with mean aortic pressures of 72.2-132.6 mm Hg for rotational speeds of 2200-3050 rpm. During LVAD support, an average flow to the distal branches (cerebral and subclavian) of 24% was found in the experiments and the nPTF. The flow fields from PIV and CFD were in good agreement. Numerical and experimental tools were combined to develop and validate the nPTF, which can be used to analyze local flow fields and the systemic response of LVADs during the design process. This allows analysis of physiological control parameters at early development stages and may, therefore, help to improve patient outcomes. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Acceptance test report: Field test of mixer pump for 241-AN-107 caustic addition project

    International Nuclear Information System (INIS)

    Leshikar, G.A.

    1997-01-01

    The field acceptance test of a 75 HP mixer pump (Hazleton serial number N-20801) installed in Tank 241-AN-107 was conducted from October 1995 thru February 1996. The objectives defined in the acceptance test were successfully met, with two exceptions recorded. The acceptance test encompassed field verification of mixer pump turntable rotation set-up and operation, verification that the pump instrumentation functions within established limits, facilitation of baseline data collection from the mixer pump mounted ultrasonic instrumentation, verification of mixer pump water flush system operation and validation of a procedure for its operation, and several brief test runs (bump) of the mixer pump

  20. Fast Flux Test Facility sodium pump operating experience - mechanical

    International Nuclear Information System (INIS)

    Buonamici, R.

    1987-11-01

    The Heat Transport System (HTS) pumps were designed, fabricated, tested, and installed in the Fast Flux Test Facility (FFTF) Plant during the period from September 1970 through July 1977. Since completion of the installation and sodium fill in December 1978, the FFTF Plant pumps have undergone extensive testing and operation with HTS testing and reactor operation. Steady-state hydraulic and mechanical performances have been and are excellent. In all, FFTF primary and secondary pumps have operated in sodium for approximately 75,000 hours and 79,000 hours, respectively, to August 24, 1987

  1. Pump testing in the nuclear industry: The comprehensive test and other considerations

    International Nuclear Information System (INIS)

    Hoyle, T.F.

    1992-01-01

    The American Society of Mechanical Engineers Operations and Maintenance Working Group on Pumps and Valves is working on a revision to their pump testing Code, ISTB-1990. This revision will change the basic philosophy of pump testing in the nuclear industry. Currently, all pumps are required to be tested quarterly, except those installed in dry sumps. In the future standby pumps will receive only a start test quarterly to ensure the pump comes up to speed and pressure or flow. Then, on a biennial basis all pumps would receive a more extensive test. This comprehensive test would require high accuracy test gauges to be used, and the pumps would be required to be tested near pump design flow. Testing on minimum flow loops would not be permitted except in rare cases. Additionally. during the comprehensive test, measurements of vibration, flow, and pressure would all be taken. The OM-6 standard (ISTB Code) will also require that reference values of flow rate and differential pressure be taken at several points instead of just one point, which is current practice. The comprehensive test is just one step in ensuring the adequacy of pump testing in the nuclear industry. This paper also addresses other concerns and makes recommendations for increased quality of testing of certain critical pumps and recommendations for less stringent or no tests on less critical pumps

  2. Nuclear Energy, Long Term Requirements

    International Nuclear Information System (INIS)

    Knapp, V.

    2006-01-01

    There are serious warnings about depletion of oil and gas and even more serious warnings about dangers of climate change caused by emission of carbon dioxide. Should developed countries be called to replace CO2 emitting energy sources as soon as possible, and the time available may not be longer then few decades, can nuclear energy answer the call and what are the requirements? Assuming optimistic contribution of renewable energy sources, can nuclear energy expand to several times present level in order to replace large part of fossil fuels use? Paper considers intermediate and long-term requirements. Future of nuclear power depends on satisfactory answers on several questions. First group of questions are those important for near and intermediate future. They deal with economics and safety of nuclear power stations in the first place. On the same time scale a generally accepted concept for radioactive waste disposal is also required. All these issues are in the focus of present research and development. Safer and more economical reactors are targets of international efforts in Generation IV and INPRO projects, but aiming further ahead these innovative projects are also addressing issues such as waste reduction and proliferation resistance. However, even assuming successful technical development of these projects, and there is no reason to doubt it, long term and large-scale nuclear power use is thereby not yet secured. If nuclear power is to play an essential role in the long-term future energy production and in reduction of CO2 emission, than several additional questions must be replied. These questions will deal with long-term nuclear fuel sufficiency, with necessary contribution of nuclear power in sectors of transport and industrial processes and with nuclear proliferation safety. This last issue is more political then technical, thus sometimes neglected by nuclear engineers, yet it will have essential role for the long-term prospects of nuclear power. The

  3. Heat pumps in field test; Waermepumpen im Feldtest

    Energy Technology Data Exchange (ETDEWEB)

    Becker, R. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Miara, M.; Russ, C.

    2007-09-15

    The Fraunhofer ISE has launched two field tests of newly installed heat pumps in 2006. Both deal with the measurement of a high number of heat pump units under real conditions in small houses. Values of volume flows, temperatures, heat quantity and electricity consumption are collected and daily saved and analysed at the Fraunhofer ISE. (orig.)

  4. Analysing long term discursive processes

    DEFF Research Database (Denmark)

    Horsbøl, Anders

    which extend beyond the single interaction, for instance negotiations or planning processes, seems to have played a less important role, with studies such as Iedema 2001 and Wodak 2000 as exceptions. These long term processes, however, are central to the constitution and workings of organizations......What do timescales - the notion that processes take place or can be viewed within a shorter or longer temporal range (Lemke 2005) - mean for the analysis of discourse? What are the methodological consequences of analyzing discourse at different timescales? It may be argued that discourse analysis...... in general has favored either the analysis of short term processes such as interviews, discussions, and lessons, or the analysis of non-processual entities such as (multimodal) texts, arguments, discursive repertoires, and discourses (in a Foucaultian sense). In contrast, analysis of long term processes...

  5. Comparing long term energy scenarios

    International Nuclear Information System (INIS)

    Cumo, M.; Simbolotti, G.

    2001-01-01

    Major projection studies by international organizations and senior analysts have been compared with reference to individual key parameters (population, energy demand/supply, resources, technology, emissions and global warming) to understand trends and implications of the different scenarios. Then, looking at the long term (i.e., 2050 and beyond), parameters and trends have been compared together to understand and quantify whether and when possible crisis or market turbulence might occur due to shortage of resources or environmental problems [it

  6. A Methodology for Evaluation of Inservice Test Intervals for Pumps and Motor-Operated Valves

    International Nuclear Information System (INIS)

    Cox, D.F.; Haynes, H.D.; McElhaney, K.L.; Otaduy, P.J.; Staunton, R.H.; Vesely, W.E.

    1999-01-01

    Recent nuclear industry reevaluation of component inservice testing (IST) requirements is resulting in requests for IST interval extensions and changes to traditional IST programs. To evaluate these requests, long-term component performance and the methods for mitigating degradation need to be understood. Determining the appropriate IST intervals, along with component testing, monitoring, trending, and maintenance effects, has become necessary. This study provides guidelines to support the evaluation of IST intervals for pumps and motor-operated valves (MOVs). It presents specific engineering information pertinent to the performance and monitoring/testing of pumps and MOVs, provides an analytical methodology for assessing the bounding effects of aging on component margin behavior, and identifies basic elements of an overall program to help ensure component operability. Guidance for assessing probabilistic methods and the risk importance and safety consequences of the performance of pumps and MOVs has not been specifically included within the scope of this report, but these elements may be included in licensee change requests

  7. Long term radioactive waste management

    International Nuclear Information System (INIS)

    Lavie, J.M.

    1984-01-01

    In France, waste management, a sensitive issue in term of public opinion, is developing quickly, and due to twenty years of experience, is now reaching maturity. With the launching of the French nuclear programme, the use of radioactive sources in radiotherapy and industry, waste management has become an industrial activity. Waste management is an integrated system dealing with the wastes from their production to the long term disposal, including their identification, sortage, treatment, packaging, collection and transport. This system aims at guaranteing the protection of present and future populations with an available technology. In regard to their long term management, and the design of disposals, radioactive wastes are divided in three categories. This classification takes into account the different radioisotopes contained, their half life and their total activity. Presently short-lived wastes are stored in the shallowland disposal of the ''Centre de la Manche''. Set up within the French Atomic Energy Commission (CEA), the National Agency for waste management (ANDRA) is responsible within the framework of legislative and regulatory provisions for long term waste management in France [fr

  8. Fast Flux Test Facility replacement of a primary sodium pump

    International Nuclear Information System (INIS)

    Krieg, S.A.; Thomson, J.D.

    1985-01-01

    The Fast Flux Test Facility is a 400 MW Thermal Sodium Cooled Fast Reactor operated by Westinghouse Hanford Company for the US Department of Energy. During startup testing in 1979, the sodium level in one of the primary sodium pumps was inadvertently raised above the normal height. This resulted in distortion of the pump shaft. Pump replacement was carried out using special maintenance equipment. Nuclear radiation and contamination were not significant problems since replacement operations were carried out shortly after startup of the Fast Flux Test Facility

  9. Empirical test of the influence of global warming and forest disturbance on ant fauna at the Gwangneung Forest Long Term Ecological Research site, South Korea

    Directory of Open Access Journals (Sweden)

    Tae-Sung Kwon

    2014-09-01

    Full Text Available This study examined the effects of forest disturbance and climate change on the ant fauna at the Long Term Ecological Research site in Gwangneung Forest, Korea in 2003 and 2012. After forest disturbance, the occurrence and abundance of ants belonging to the functional groups of forest ground forager and soil and litter dweller are predicted to decrease, while the occurrence and abundance of ants belonging to the open land forager and forest vegetation forager functional groups are predicted to increase. In terms of the effects of climate change, if the optimum temperature of the ants is lower than the annual average temperature in the survey area, the occurrence and abundance of the ants are predicted to decrease and vice versa. Ant surveys were carried out using pitfall traps. Changes in the dominant species, occurrence, and abundance mostly corresponded to the predictions for forest disturbance, but did not match the prediction for an increase in temperature.

  10. The Sabah Biodiversity Experiment: a long-term test of the role of tree diversity in restoring tropical forest structure and functioning

    Science.gov (United States)

    Hector, Andy; Philipson, Christopher; Saner, Philippe; Chamagne, Juliette; Dzulkifli, Dzaeman; O'Brien, Michael; Snaddon, Jake L.; Ulok, Philip; Weilenmann, Maja; Reynolds, Glen; Godfray, H. Charles J.

    2011-01-01

    Relatively, little is known about the relationship between biodiversity and ecosystem functioning in forests, especially in the tropics. We describe the Sabah Biodiversity Experiment: a large-scale, long-term field study on the island of Borneo. The project aims at understanding the relationship between tree species diversity and the functioning of lowland dipterocarp rainforest during restoration following selective logging. The experiment is planned to run for several decades (from seed to adult tree), so here we focus on introducing the project and its experimental design and on assessing initial conditions and the potential for restoration of the structure and functioning of the study system, the Malua Forest Reserve. We estimate residual impacts 22 years after selective logging by comparison with an appropriate neighbouring area of primary forest in Danum Valley of similar conditions. There was no difference in the alpha or beta species diversity of transect plots in the two forest types, probably owing to the selective nature of the logging and potential effects of competitive release. However, despite equal total stem density, forest structure differed as expected with a deficit of large trees and a surfeit of saplings in selectively logged areas. These impacts on structure have the potential to influence ecosystem functioning. In particular, above-ground biomass and carbon pools in selectively logged areas were only 60 per cent of those in the primary forest even after 22 years of recovery. Our results establish the initial conditions for the Sabah Biodiversity Experiment and confirm the potential to accelerate restoration by using enrichment planting of dipterocarps to overcome recruitment limitation. What role dipterocarp diversity plays in restoration only will become clear with long-term results. PMID:22006970

  11. Development and test of a plastic deep-well pump

    International Nuclear Information System (INIS)

    Zhang, Q H; Gao, X F; Xu, Y; Shi, W D; Lu, W G; Liu, W

    2013-01-01

    To develop a plastic deep-well pump, three methods are proposed on structural and forming technique. First, the major hydraulic components are constructed by plastics, and the connection component is constructed by steel. Thus the pump structure is more concise and slim, greatly reducing its weight and easing its transportation, installation, and maintenance. Second, the impeller is designed by maximum diameter method. Using same pump casing, the stage head is greatly increased. Third, a sealing is formed by impeller front end face and steel end face, and two slots are designed on the impeller front end face, thus when the two end faces approach, a lubricating pair is formed, leading to an effective sealing. With above methods, the pump's axial length is greatly reduced, and its stage head is larger and more efficient. Especially, the pump's axial force is effectively balanced. To examine the above proposals, a prototype pump is constructed, and its testing results show that the pump efficiency exceeds the national standard by 6%, and the stage head is improved by 41%, meanwhile, its structure is more concise and ease of transportation. Development of this pump would provide useful experiences for further popularity of plastic deep-well pumps

  12. Test specification for decant pump and winch assembly. Revision 2

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1995-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction with load sensing winch control, instrumentation and the associated PLC/PC control system. All assembly necessary for testing including piping, temporary wiring, etc., shall be performed by the Seller. All referenced figures are at the back of this document. The testing consists of performance testing, winch testing and calibration, instrumentation verification testing and run-in testing of the pump. Testing shall be done in the presence and under the direction of the Buyer in accordance with this procedure

  13. Long term evolution 4G and beyond

    CERN Document Server

    Yacoub, Michel; Figueiredo, Fabrício; Tronco, Tania

    2016-01-01

    This book focus on Long Term Evolution (LTE) and beyond. The chapters describe different aspects of research and development in LTE, LTE-Advanced (4G systems) and LTE-450 MHz such as telecommunications regulatory framework, voice over LTE, link adaptation, power control, interference mitigation mechanisms, performance evaluation for different types of antennas, cognitive mesh network, integration of LTE network and satellite, test environment, power amplifiers and so on. It is useful for researchers in the field of mobile communications.

  14. Performance test of a ceramic turbo-viscous pump

    International Nuclear Information System (INIS)

    Abe, Tetsuya; Hiroki, Seiji; Murakami, Yoshio; Shiraishi, Shigeyuki; Totoura, Sadayuki; Ohtaki, Takashi.

    1994-01-01

    In the special fields of nuclear fusion facilities and semiconductor production installation, the development of new vacuum pumps which can cope with strong magnetic fields, high temperature gas and corrosive gas is demanded. Mitsubishi Heavy Industries Ltd. has advanced the development of ceramic turbo-molecular pumps and ceramic turbo-viscous pumps, which use ceramic rotors and gas bearings since 1985. The evaluation test of the ceramic turbo-viscous vacuum pump CT-3000H which can evacuate from atmospheric pressure to high vacuum with one pump was carried out, and the experimental results on the performance and the reliability were obtained, therefore, those are reported in this paper. The structure, specification and features of the CT-3000H are shown. The exhaust performance test of the pump was carried out in conformity with the standard of the Vacuum Society of Japan, JVIS 005 'Method of performance test for turbo-molecular pumps'. The gases used were nitrogen and helium. The results are shown. The exhaust test from atmospheric pressure was carried out by two methods, and the results are shown. (K.I.)

  15. Test specification for decant pump and winch assembly

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1994-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction arm with load sensing winch control, instrumentation and the associated PLC/PC control system

  16. Radial-piston pump for drive of test machines

    Science.gov (United States)

    Nizhegorodov, A. I.; Gavrilin, A. N.; Moyzes, B. B.; Cherkasov, A. I.; Zharkevich, O. M.; Zhetessova, G. S.; Savelyeva, N. A.

    2018-01-01

    The article reviews the development of radial-piston pump with phase control and alternating-flow mode for seismic-testing platforms and other test machines. The prospects for use of the developed device are proved. It is noted that the method of frequency modulation with the detection of the natural frequencies is easily realized by using the radial-piston pump. The prospects of further research are given proof.

  17. Long-term biodosimetry Redux

    International Nuclear Information System (INIS)

    Simon, Steven L.; Bouville, Andre

    2016-01-01

    This paper revisits and reiterates the needs, purposes and requirements of bio-dosimetric assays for long-term dose and health risk assessments. While the most crucial need for bio-dosimetric assays is to guide medical response for radiation accidents, the value of such techniques for improving our understanding of radiation health risk by supporting epidemiological (long-term health risk) studies is significant. As new cohorts of exposed persons are identified and new health risk studies are undertaken with the hopes that studying the exposed will result in a deeper understanding of radiation risk, the value of reliable dose reconstruction is underscored. The ultimate application of biodosimetry in long-term health risk studies would be to completely replace model-based dose reconstruction-a complex suite of methods for retrospectively estimating dose that is commonly fraught with large uncertainties due to the absence of important exposure-related information, as well as imperfect models. While biodosimetry could potentially supplant model-based doses, there are numerous limitations of presently available techniques that constrain their widespread application in health risk research, including limited ability to assess doses received far in the past, high cost, great inter-individual variability, invasiveness, higher than preferred detection limits and the inability to assess internal dose (for the most part). These limitations prevent the extensive application of biodosimetry to large cohorts and should be considered a challenge to researchers to develop new and more flexible techniques that meet the demands of long-term health risk research. Events in recent years, e.g. the Fukushima reactor accident and the increased threat of nuclear terrorism, underscore that any event that results in significant radiation exposures of a group of people will also produce a much larger population, exposed at lower levels, but that likewise needs (or demands) an exposure

  18. Test report for run-in acceptance testing of Project W-151 300 HP mixing pumps

    International Nuclear Information System (INIS)

    Berglin, B.G.

    1998-01-01

    This report documents the results of a performance demonstration and operational checkout of three 300 HP mixer pumps in accordance with WHC-SD-WI51-TS-001 ''Mixer Pump Test Specification for Project W-151'' and Statement of Work 8K520-EMN-95-004 ''Mixer Pump Performance Demonstration at MASF'' in the 400 Area Maintenance and Storage Facility (MASF) building. Testing of the pumps was performed by Fast Flux Test Facility (FFTF) Engineering and funded by the Tank Waste Remediation System (TWRS) Project W-151. Testing began with the first pump on 04-01-95 and ended with the third pump on 11-01-96. Prior to testing, the MASF was modified and prepared to meet the pump testing requirements set forth by the Test Specification and the Statement of Work

  19. Predicting short and long-term exercise intentions and behaviour in patients with coronary artery disease: A test of protection motivation theory.

    Science.gov (United States)

    Tulloch, Heather; Reida, Robert; D'Angeloa, Monika Slovinec; Plotnikoff, Ronald C; Morrina, Louise; Beatona, Louise; Papadakisa, Sophia; Pipe, Andrew

    2009-03-01

    The purpose of this study was to examine the utility of protection motivation theory (PMT) in the prediction of exercise intentions and behaviour in the year following hospitalisation for coronary artery disease (CAD). Patients with documented CAD (n = 787), recruited at hospital discharge, completed questionnaires measuring PMT's threat (i.e. perceived severity and vulnerability) and coping (i.e. self-efficacy, response efficacy) appraisal constructs at baseline, 2 and 6 months, and exercise behaviour at baseline, 6 and 12 months post-hospitalisation. Structural equation modelling showed that the PMT model of exercise at 6 months had a good fit with the empirical data. Self-efficacy, response efficacy, and perceived severity predicted exercise intentions, which, in turn predicted exercise behaviour. Overall, the PMT variables accounted for a moderate amount of variance in exercise intentions (23%) and behaviour (20%). In contrast, the PMT model was not reliable for predicting exercise behaviour at 12 months post-hospitalisation. The data provided support for PMT applied to short-term, but not long-term, exercise behaviour among patients with CAD. Health education should concentrate on providing positive coping messages to enhance patients' confidence regarding exercise and their belief that exercise provides health benefits, as well as realistic information about disease severity.

  20. Long term stability of power systems

    Energy Technology Data Exchange (ETDEWEB)

    Kundur, P; Gao, B [Powertech Labs. Inc., Surrey, BC (Canada)

    1994-12-31

    Power system long term stability is still a developing subject. In this paper we provide our perspectives and experiences related to long term stability. The paper begins with the description of the nature of the long term stability problem, followed by the discussion of issues related to the modeling and solution techniques of tools for long term stability analysis. Cases studies are presented to illustrate the voltage stability aspect and plant dynamics aspect of long term stability. (author) 20 refs., 11 figs.

  1. Hydrodynamical tests with an original PWR heat removal pump

    International Nuclear Information System (INIS)

    Wietstock, P.

    1984-01-01

    GKSS-Forschungszentrum performes hydrodynamical tests with an original PWR heat removal pump to analyse the influences of fluid parameters on the capacity and cavitation behavior of the pump in order to get further improvements of the quantification of the reached safety-level. It can be concluded, that in case of the tested heat removal pump the additional loads during transition from cavitation free operation into fully cavitation for the investigated operation point with 980 m 3 /h will be smaller than the alteration of loads during passing through the total characteristic. The results from cavitation tests for other operation points indicate, that this very important consequence especially for accident operation will be valid for the total specified pump flow area. (orig.)

  2. Experimental Researches on Long-Term Strength of Granite Gneiss

    Directory of Open Access Journals (Sweden)

    Lin Liu

    2015-01-01

    Full Text Available It is important to confirm the long-term strength of rock materials for the purpose of evaluating the long-term stability of rock engineering. In this study, a series of triaxial creep tests were conducted on granite gneiss under different pore pressures. Based on the test data, we proposed two new quantitative methods, tangent method and intersection method, to confirm the long-term strength of rock. Meanwhile, the isochronous stress-strain curve method was adopted to make sure of the accuracy and operability of the two new methods. It is concluded that the new methods are suitable for the study of the long-term strength of rock. The effect of pore pressure on the long-term strength of rock in triaxial creep tests is also discussed.

  3. Fabrication and testing of main sodium pumps of Superphenix 1

    International Nuclear Information System (INIS)

    Noel, H.; Pasqualini, G.

    1985-01-01

    The complexity of the loads involved and the extremely fine analysis required necessitates extensive design calculations for the Superphenix 1 primary and secondary pumps and associated expansion tanks, aiming toward detailed design validation, after slight adjustments, mainly to the secondary pumps and expansion tanks. The component parts to be built were far larger than those for the previous pumps (Rapsodie, Phenix), with very low manufacturing tolerances, which led to precision machining and welding operations, together with numerous dimensional inspections and materials characterization tests to achieve the required quality standards

  4. Long-term performance potential of concentrated photovoltaic (CPV) systems

    KAUST Repository

    Burhan, Muhammad; Shahzad, Muhammad Wakil; Ng, Kim Choon

    2017-01-01

    estimation of a large PV field, the long term performance as electrical output is a more rational approach over the conventional testing methods, such as at Standard Testing Conditions (STC) and at the Nominal Operating Cell Temperature (NOCT) available

  5. Navigating Long-Term Care

    Directory of Open Access Journals (Sweden)

    James D. Holt MD

    2017-03-01

    Full Text Available Americans over age 65 constitute a larger percentage of the population each year: from 14% in 2010 (40 million elderly to possibly 20% in 2030 (70 million elderly. In 2015, an estimated 66 million people provided care to the ill, disabled, and elderly in the United States. In 2000, according to the Centers for Disease Control and Prevention (CDC, 15 million Americans used some form of long-term care: adult day care, home health, nursing home, or hospice. In all, 13% of people over 85 years old, compared with 1% of those ages 65 to 74, live in nursing homes in the United States. Transitions of care, among these various levels of care, are common: Nursing home to hospital transfer, one of the best-studied transitions, occurs in more than 25% of nursing home residents per year. This article follows one patient through several levels of care.

  6. Long-Term Memory Performance in Adult ADHD.

    Science.gov (United States)

    Skodzik, Timo; Holling, Heinz; Pedersen, Anya

    2017-02-01

    Memory problems are a frequently reported symptom in adult ADHD, and it is well-documented that adults with ADHD perform poorly on long-term memory tests. However, the cause of this effect is still controversial. The present meta-analysis examined underlying mechanisms that may lead to long-term memory impairments in adult ADHD. We performed separate meta-analyses of measures of memory acquisition and long-term memory using both verbal and visual memory tests. In addition, the influence of potential moderator variables was examined. Adults with ADHD performed significantly worse than controls on verbal but not on visual long-term memory and memory acquisition subtests. The long-term memory deficit was strongly statistically related to the memory acquisition deficit. In contrast, no retrieval problems were observable. Our results suggest that memory deficits in adult ADHD reflect a learning deficit induced at the stage of encoding. Implications for clinical and research settings are presented.

  7. Test Procedure - pumping system for caustic addition project

    International Nuclear Information System (INIS)

    Leshikar, G.A.

    1994-01-01

    This test procedure provides the requirements for sub-system testing and integrated operational testing of the submersible mixer pump and caustic addition equipment by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E)

  8. Multiphase pumping: indoor performance test and oilfield application

    Science.gov (United States)

    Kong, Xiangling; Zhu, Hongwu; Zhang, Shousen; Li, Jifeng

    2010-03-01

    Multiphase pumping is essentially a means of adding energy to the unprocessed effluent which enables the liquid and gas mixture to be transported over a long distances without prior separation. A reduction, consolidation, or elimination of the production infrastructure, such as separation equipments and offshore platforms can be developed more economically. Also it successfully lowed the backpressure of wells, revived dead wells and improved the production and efficiency of oilfield. This paper reviews the issues related to indoor performance test and an oilfield application of the helico-axial multiphase pump designed by China University of Petroleum (Beijing). Pump specification and its hydraulic design are given. Results of performance testing under different condition, such as operational speed and gas volume fraction (GVF) etc are presented. Experimental studies on combination of theoretical analysis showed the multiphase pump satisfies the similitude rule, which can be used in the development of new MPP design and performance prediction. Test results showed that rising the rotation speed and suction pressure could better its performance, pressure boost improved, high efficiency zone expanding and the flow rate related to the optimum working condition increased. The pump worked unstable as GVF increased to a certain extent and slip occurred between two phases in the pump, creating surging and gas lock at a high GVF. A case of application in Nanyang oilfield is also studied.

  9. Performance Tests of a Mechanical Pump in Sodium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Water is often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Nevertheless, to ensure the performance, safety, and operability of major components before its installation in the SFR, a series of demonstration experiments of some components in sodium environment should be positively necessary. So, SFR NSSS System Design Division of Korea Atomic Energy Research Institute (KAERI) built various sodium experimental facilities, especially STELLA-1 in 2012. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separated effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS). The mechanical pump in-sodium performance test was successfully performed with good reproducibility of the experiment and data to compare hydraulic characteristic of a mechanical pump in-water was collected. In effect of temperature variation on the pump pressure head, reduction of pump pressure head at 250℃ by 0.57% of that of 300℃ maybe the result of an increase in sodium viscosity by 13.6% according to operating temperature decrease by 50℃. Also, we confirmed that the more flywheel weight, the longer halving time and the more initial flow rate when the pump seized, the shorter halving time. The results of the mechanical pump performance test data in sodium environment will be used to compare with that of the in water environment after the evaluation of measurement uncertainty for tests.

  10. Procurement specification high vacuum test chamber and pumping system

    International Nuclear Information System (INIS)

    1976-01-01

    The specification establishes requirements for a high-vacuum test chamber, associated vacuum pumps, valves, controls, and instrumentation that shall be designed and fabricated for use as a test chamber for testing a closed loop Brayton Isotope Power System (BIPS) Ground Demonstration System (GDS). The vacuum system shall include all instrumentation required for pressure measurement and control of the vacuum pumping system. A general outline of the BIPS-GDS in the vacuum chamber and the preliminary piping and instrumentation interface to the vacuum chamber are shown

  11. Transcranial focal electrical stimulation via tripolar concentric ring electrodes does not modify the short- and long-term memory formation in rats evaluated in the novel object recognition test.

    Science.gov (United States)

    Rogel-Salazar, G; Luna-Munguía, H; Stevens, K E; Besio, W G

    2013-04-01

    Noninvasive transcranial focal electrical stimulation (TFS) via tripolar concentric ring electrodes (TCREs) has been under development as an alternative/complementary therapy for seizure control. Transcranial focal electrical stimulation has shown efficacy in attenuating penicillin-, pilocarpine-, and pentylenetetrazole-induced acute seizures in rat models. This study evaluated the effects of TFS via TCREs on the memory formation of healthy rats as a safety test of TFS. Short- and long-term memory formation was tested after the application of TFS using the novel object recognition (NOR) test. The following independent groups were used: naïve, control (without TFS), and TFS (treated). The naïve, control, and stimulated groups spent more time investigating the new object than the familiar one during the test phase. Transcranial focal electrical stimulation via TCREs given once does not modify the short- and long-term memory formation in rats in the NOR test. Results provide an important step towards a better understanding for the safe usage of TFS via TCREs. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Long-term competence restoration.

    Science.gov (United States)

    Morris, Douglas R; DeYoung, Nathaniel J

    2014-01-01

    While the United States Supreme Court's Jackson v. Indiana decision and most state statutes mandate determinations of incompetent defendants' restoration probabilities, courts and forensic clinicians continue to lack empirical evidence to guide these determinations and do not yet have a consensus regarding whether and under what circumstances incompetent defendants are restorable. The evidence base concerning the restoration likelihood of those defendants who fail initial restoration efforts is even further diminished and has largely gone unstudied. In this study, we examined the disposition of a cohort of defendants who underwent long-term competence restoration efforts (greater than six months) and identified factors related to whether these defendants were able to attain restoration and adjudicative success. Approximately two-thirds (n = 52) of the 81 individuals undergoing extended restoration efforts were eventually deemed restored to competence. Lengths of hospitalization until successful restoration are presented with implications for the reasonable length of time that restoration efforts should persist. Older individuals were less likely to be restored and successfully adjudicated, and individuals with more severe charges and greater factual legal understanding were more likely to be restored and adjudicated. The significance of these findings for courts and forensic clinicians is discussed.

  13. Uranium ... long-term confidence

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Half way through 1983 the outlook for the world's uranium producers was far from bright if one takes a short term view. The readily accessible facts present a gloomy picture. The spot prices of uranium over the past few years decreased from a high of $42-$43/lb to a low of $17 in 1982. It now hovers between $23 and $24. the contract prices negotiated between producers and consumers are not so accessible but they do not reflect the spot price. The reasons why contractual uranium prices do not follow the usual dictates of supply and demand are related to the position in which uranium and associated power industries find themselves. There is public reaction with strong emotional overtones as well as much reduced expectations about the electric power needs of the world. Furthermore the supply of uranium is not guaranteed despite present over production. However the people in the industry, taking the medium- and long-term view, are not despondent

  14. Endurance Pump Tests With Fresh and Purified MIL-PRF-83282 Hydraulic Fluid

    National Research Council Canada - National Science Library

    Sharma, Shashi

    1999-01-01

    .... Two endurance pump tests were conducted with F-16 aircraft hydraulic pumps, using both fresh and purified MIL-PRF-83282 hydraulic fluid, to determine if fluid purification had any adverse effect on pump life...

  15. How Can Paresthesia After Zygomaticomaxillary Complex Fracture Be Determined After Long-Term Follow-Up? A New and Quantitative Evaluation Method Using Current Perception Threshold Testing.

    Science.gov (United States)

    Okochi, Masayuki; Ueda, Kazuki; Mochizuki, Yasushi; Okochi, Hiromi

    2015-08-01

    The aims of the present study were to analyze the effectiveness of current perception threshold (CPT) testing to determine patients' minor paresthesia of the infraorbital region after open reduction and internal fixation (ORIF) for unilateral zygomaticomaxillary bone fracture (UZF) and to clarify which nerve fiber was related to the paresthesia. We conducted a retrospective cohort study of patients who had undergone ORIF after UZF. We also performed neurosensory testing for healthy volunteers who served as the control group. The predictor variables were the period of measurement of Semmes-Weinstein monofilament (S-W) testing and CPT testing (preoperatively and 1 and 5 years postoperatively), measurement side, and disease status (UZF or control). The outcome variables were paresthesia status of the infraorbital nerve region and the results of S-W and CPT testing in both UZF and control groups. The differences in the S-W and CPT values between the affected and unaffected sides in the UZF group and between the UZF and control groups were analyzed by t test (P paresthesia at 1 and 5 years postoperatively. At 5 years postoperatively, the S-W values in all patients showed normalization. From the results of CPT testing, only the A-β fiber function showed significant improvement at 5 years postoperatively. The CPT test was an effective sensory test for determining minor paresthesia that could not be detected using S-W testing. Paresthesia of the infraorbital nerve region was caused by the damaged A-δ and C fibers. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Statistical analysis of long term spatial and temporal trends of ...

    Indian Academy of Sciences (India)

    Statistical analysis of long term spatial and temporal trends of temperature ... CGCM3; HadCM3; modified Mann–Kendall test; statistical analysis; Sutlej basin. ... Water Resources Systems Division, National Institute of Hydrology, Roorkee 247 ...

  17. Simulation of long-term behavior in HLW near-field by centrifugal model test. Part 4. Model test of coupled THM processes in isotropic stress conditions using heatable overpack

    International Nuclear Information System (INIS)

    Nishimoto, Soshi; Okada, Tetsuji; Sawada, Masataka

    2014-01-01

    We demonstrated the equivalent long-term behavior in the near-field of a geological repository for high level radioactive waste disposal, using the centrifugal near-field model test under the coupled thermo-hydraulic-mechanical condition. The model consisted of a sedimentary bedrock, buffer, and heating type model overpack, and was enclosed within a pressure vessel. Tests were conducted with a centrifugal force field of 30 G under isotropic stress-constrain conditions with confining pressures and injection of pore water. The temperature condition of the overpack was constantly 95°C. As the result, the values showed similar behaviors to that of the normal temperature tests partially. However, the different behaviors were measured such as the displacement of overpack change from the settlement to the heave, the extreme drop in the soil pressure of the buffer and the strain of side wall of bedrock change from the tension to the compression after injecting pore water of hundreds hours. In addition, the flow rate of the injection pore water suddenly changed after hundreds of hours. Furthermore, the density of the buffer was lower than that of the normal temperature tests by X-ray CT imaging in the post-tests. We infer that the high temperature overpack influenced the stiffness and the pore water distribution of the buffer, and the density and the soil pressure of the buffer decreased. As a result of the change of stiffness in the disposal hole (buffer), the tendency to the strain of the surrounding bedrock and the displacement of the overpack changed. (author)

  18. Test report for run-in acceptance testing of hydrogen mitigation test pump-2

    International Nuclear Information System (INIS)

    Brewer, A.K.; Kolowith, R.

    1995-01-01

    This document provides the results of the run-in test of the replacement mixer pump for the Tank 241-SY-101. The test was conducted at the 400 Area MASF facility between August 12 and September 29, 1994. The report includes findings, analysis, recommendations, and corrective actions taken

  19. Qualification test of a main coolant pump for SMART pilot

    International Nuclear Information System (INIS)

    Park, Sang Jin; Yoon, Eui Soo; Oh, Hyong Woo

    2006-01-01

    SMART Pilot is a multipurpose small capacity integral type reactor. Main Coolant Pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of 310 .deg. C and 14.7 MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present work, a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and life-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP

  20. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  1. Potential long-term chemical effects of diesel fuel emissions on a mining environment: A preliminary assessment based on data from a deep subsurface tunnel at Rainer Mesa, Nevada test site

    International Nuclear Information System (INIS)

    Meike, A.; Bourcier, W.L.; Alai, M.

    1995-09-01

    The general purpose of the Yucca Mountain Site Characterization Project (YMSCP) Introduced Materials Task is to understand and predict potential long-term modifications of natural water chemistry related to the construction and operation of a radioactive waste repository that may significantly affect performance of the waste packages. The present study focuses on diesel exhaust. Although chemical information on diesel exhaust exists in the literature, it is either not explicit or incomplete, and none of it establishes mechanisms that might be used to predict long-term behavior. In addition, the data regarding microbially mediated chemical reactions are not well correlated with the abiotic chemical data. To obtain some of the required long-term information, we chose a historical analog: the U12n tunnel at Rainier Mesa, Nevada Test Site. This choice was based on the tunnel's extended (30-year) history of diesel usage, its geological similarity to Yucca Mountain, and its availability. The sample site within the tunnel was chosen based on visual inspection and on information gathered from miners who were present during tunnel operations. The thick layer of dark deposit at that site was assumed to consist primarily of rock powder and diesel exhaust. Surface samples and core samples were collected with an intent to analyze the deposit and to measure potential migration of chemical components into the rock. X-ray diffraction (XRD), x-ray fluorescence (XRF), scanning electron microscopy (SEM) with energy dispersive spectra (EDS) analysis, secondary-ion mass spectrometry (SIMS), and Fourier transform infrared (FTIR) analysis were used to measure both spatial distribution and concentration for the wide variety of chemical components that were expected based on our literature survey

  2. Potential long-term chemical effects of diesel fuel emissions on a mining environment: A preliminary assessment based on data from a deep subsurface tunnel at Rainer Mesa, Nevada test site

    Energy Technology Data Exchange (ETDEWEB)

    Meike, A.; Bourcier, W.L.; Alai, M. [and others

    1995-09-01

    The general purpose of the Yucca Mountain Site Characterization Project (YMSCP) Introduced Materials Task is to understand and predict potential long-term modifications of natural water chemistry related to the construction and operation of a radioactive waste repository that may significantly affect performance of the waste packages. The present study focuses on diesel exhaust. Although chemical information on diesel exhaust exists in the literature, it is either not explicit or incomplete, and none of it establishes mechanisms that might be used to predict long-term behavior. In addition, the data regarding microbially mediated chemical reactions are not well correlated with the abiotic chemical data. To obtain some of the required long-term information, we chose a historical analog: the U12n tunnel at Rainier Mesa, Nevada Test Site. This choice was based on the tunnel`s extended (30-year) history of diesel usage, its geological similarity to Yucca Mountain, and its availability. The sample site within the tunnel was chosen based on visual inspection and on information gathered from miners who were present during tunnel operations. The thick layer of dark deposit at that site was assumed to consist primarily of rock powder and diesel exhaust. Surface samples and core samples were collected with an intent to analyze the deposit and to measure potential migration of chemical components into the rock. X-ray diffraction (XRD), x-ray fluorescence (XRF), scanning electron microscopy (SEM) with energy dispersive spectra (EDS) analysis, secondary-ion mass spectrometry (SIMS), and Fourier transform infrared (FTIR) analysis were used to measure both spatial distribution and concentration for the wide variety of chemical components that were expected based on our literature survey.

  3. Long term evaluation of building energy performance : comparison of the test reference year and historical data series in the North Italian climates

    NARCIS (Netherlands)

    Pernigotto, G.; Antonacci, G.; Baggio, P.; Gasparella, A.; Hensen, J.L.M.; Baratieri, M.; Corrado, V.; Gasparella, A.; Patuzzi, F.

    2013-01-01

    The pursuit of better energy performance of buildings led o the recourse to more detailed instruments of analysis, requiring more complex and detailed inputs, such as the hourly weather data. In this work, the representativeness of the test reference year (TRYEN) weather data, recently developed in

  4. [The Russian-language version of the matrix test (RUMatrix) in free field in patients after cochlear implantation in the long term].

    Science.gov (United States)

    Goykhburg, M V; Bakhshinyan, V V; Petrova, I P; Wazybok, A; Kollmeier, B; Tavartkiladze, G A

    The deterioration of speech intelligibility in the patients using cochlear implantation (CI) systems is especially well apparent in the noisy environment. It explains why phrasal speech tests, such as a Matrix sentence test, have become increasingly more popular in the speech audiometry during rehabilitation after CI. The Matrix test allows to estimate speech perception by the patients in a real life situation. The objective of this study was to assess the effectiveness of audiological rehabilitation of CI patients using the Russian-language version of the matrix test (RUMatrix) in free field in the noisy environment. 33 patients aged from 5 to 40 years with a more than 3 year experience of using cochlear implants inserted at the National Research Center for Audiology and Hearing Rehabilitation were included in our study. Five of these patients were implanted bilaterally. The results of our study showed a statistically significant improvement of speech intelligibility in the noisy environment after the speech processor adjustment; dynamics of the signal-to-noise ratio changes was -1.7 dB (planguages makes possible its application in international multicenter studies.

  5. Math Self-Concept, Grades, and Achievement Test Scores: Long-Term Reciprocal Effects across Five Waves and Three Achievement Tracks

    Science.gov (United States)

    Arens, A. Katrin; Marsh, Herbert W.; Pekrun, Reinhard; Lichtenfeld, Stephanie; Murayama, Kou; vom Hofe, Rudolf

    2017-01-01

    This study examines reciprocal effects between self-concept and achievement by considering a long time span covering grades 5 through 9. Extending previous research on the reciprocal effects model (REM), this study tests (1) the assumption of developmental equilibrium as time-invariant cross-lagged paths from self-concept to achievement and from…

  6. A quality assurance program of simulators in radiotherapy. Pt. 2. Extent and results of long-term quality assurance tests on a therapy simulator

    International Nuclear Information System (INIS)

    Mueller-Sievers, K.; Kober, B.

    1997-01-01

    Background: Since 1990 we follow a quality assurance program with periodical tests of functional performance values of a 16-year-old simulator. Material and Method: For this purpose we adopted and modified German standards for quality assurance on linear accelerators and international standards elaborated for simulators (International Electrotechnical Commission). The tests are subdivided into daily visual checks (light field indication, optical distance indicator, isocentre-indicating devices, indication of gantry and collimator angles) and monthly and annually tests of relevant simulator parameters. Some important examples demonstrate the small variation of parameters over 6 years: Position of the light field centre when rotating the collimator, diameter of the isocentre circle when rotating the gantry, accuracy of the isocentre indication device, and coincidence of light field and simulated radiation field. Results: As an important result we can state, that by these rigid periodic tests it was possible to detect and compensate deteriorations of simulators quality rapidly. Conclusions: Technical improvements and specific calling-in of maintenance personnel whenever felt appropriate provided performance characteristics of our old simulator which are required by international recommendations as a basis for modern radiotherapy. (orig.) [de

  7. Understanding the Alteration of Bentonite Backfill Using Coupled THMC Modeling for a Long Term Heater Test at the Grimsel Underground Research Lab

    Science.gov (United States)

    Birkholzer, J. T.; Zheng, L.; Xu, H.; Rutqvist, J.

    2017-12-01

    Compacted bentonite is commonly used as backfill material in emplacement tunnels of nuclear waste repositories because of its low permeability, high swelling pressure, and retardation capacity of radionuclide. To assess whether this backfill material can maintain these favorable features when undergoing heating from the waste package and hydration from the host rock, we need a thorough understanding of the thermal, hydrological, mechanical, and chemical evolution of bentonite under disposal conditions. Dedicated field tests integrated with THMC modeling provide an effective way to deepen such understanding. Here, we present coupled THMC models for an in situ heater test which was conducted at the Grimsel Test Site in Switzerland for 18 years. The comprehensive monitoring data obtained in the test provide a unique opportunity to evaluate bentonite integrity and test coupled THMC models. We developed a modeling strategy where conceptual model complexity is increased gradually by adding/testing processes such as Non-Darcian flow, enhanced vapor diffusion, thermal osmosis and different constitutive relationships for permeability/porosity changes due to swelling. The final THMC model explains well all the THM data and the concentration profiles of conservative chemical species. Over the course of modeling the in situ test, we learned that (1) including Non-Darcian flow into the model leads to a significant underestimation of hydration rate of bentonite, (2) chemical data provide an important additional piece of information for calibrating a THM model; (3) key processes needed to reproduce the data include vapor diffusion, as well as porosity and permeability changes due to swelling and thermal osmosis; (4) the concentration profiles of cations (calcium, potassium, magnesium and sodium) were largely shaped by transport processes despite their concentration levels being affected by mineral dissolution/precipitation and cation exchange. The concentration profiles of p

  8. Evaluation of long term leaching of borosilicate glasses

    International Nuclear Information System (INIS)

    Lanza, F.; Parnisari, E.

    1978-01-01

    For the evaluation of long term hazard of glass, data on long term glass leaching are needed. Moreover for long term leaching a model of homogeneous dissolution seems reasonable and ask for confirmation. Tests were performed at 30 0 , 80 0 , 100 0 , using an apparatus of the Soxhlet type, to 3.600 hours. Results were obtained as a weight loss and analysed following a relation with time composed by a parabolic and a linear part. Analysis of the surface layer using energy dispersion X ray spectrometry were performed. A critical analysis of the results and of the apparatus is presented

  9. The experimental testing of the long-term behaviour of cemented radioactive waste from nuclear research reactors in the geological disposal conditions of the boom clay

    International Nuclear Information System (INIS)

    Sneyers, A.; Marivoet, J.; Iseghem, P. van

    1998-01-01

    Liquid wastes, resulting from the reprocessing of spent nuclear fuel from the BR-2 Materials Testing Reactor, will be conditioned in a cement matrix at the dedicated cementation facility of UKAEA at Dounreay. In Belgium, the Boom clay formation is studied as a potential host rock for the final geological disposal of cemented research reactor waste. In view of evaluating the safety of disposal, laboratory leach experiments and in situ tests have been performed. Leach experiments in synthetic clay water indicate that the leach rates of calcium and silicium are relatively low compared to those of sodium and potassium. In situ experiments on inactive samples are performed in order to obtain information on the microchemical and mineralogical changes of the cemented waste in contact with the Boom clay. Finally, results from a preliminary performance assessment calculation suggest a non-negligible maximum dose rate of 5 10 -9 Sv/a for 129 I. (author)

  10. The experimental testing of the long-term behaviour of cemented radioactive waste from nuclear research reactors in the geological disposal conditions of the boom clay

    Energy Technology Data Exchange (ETDEWEB)

    Sneyers, A.; Marivoet, J.; Iseghem, P. van [SCK-CEN, B-2400 Mol (Belgium)

    1998-07-01

    Liquid wastes, resulting from the reprocessing of spent nuclear fuel from the BR-2 Materials Testing Reactor, will be conditioned in a cement matrix at the dedicated cementation facility of UKAEA at Dounreay. In Belgium, the Boom clay formation is studied as a potential host rock for the final geological disposal of cemented research reactor waste. In view of evaluating the safety of disposal, laboratory leach experiments and in situ tests have been performed. Leach experiments in synthetic clay water indicate that the leach rates of calcium and silicium are relatively low compared to those of sodium and potassium. In situ experiments on inactive samples are performed in order to obtain information on the microchemical and mineralogical changes of the cemented waste in contact with the Boom clay. Finally, results from a preliminary performance assessment calculation suggest a non-negligible maximum dose rate of 5 10{sup -9} Sv/a for {sup 129}I. (author)

  11. Hydraulic properties from pumping tests data of aquifers in Azare ...

    African Journals Online (AJOL)

    Pumping test data from twelve boreholes in Azare area were analysed to determine the hydraulic properties of the aquifers, and the availability of water to meet the conjugate demands of the increasing population. The values of the aquifer constants obtained from the Cooper-Jacob's non-equilibrium graphical method were ...

  12. Ability of the rhTSH stimulation test to predict relapse in patients with differentiated thyroid carcinoma, after long-term follow-up

    Science.gov (United States)

    MARCELINO, MAFALDA; LOPES, ANA FILIPA; MADUREIRA, DEOLINDA; FERREIRA, TERESA C.; LIMBERT, EDWARD; LEITE, VALERIANO

    2015-01-01

    The analysis of serum thyroglobulin (Tg) following thyroid-stimulating hormone (TSH) stimulation (sTg) has been recommended in the follow-up of differentiated thyroid carcinoma (DTC) patients, however, its routine use remains controversial. The aim of the current study was to evaluate the accuracy of sTg testing following recombinant human (rh) TSH stimulation in DTC patients, with a follow-up of 12.4 years. Retrospective studies were conducted of 125 DTC patients, who underwent rhTSH stimulation testing between 1999 and 2002. The exclusion criteria were: Patients with anti-Tg antibodies, Tg levels >1 ng/ml under TSH suppression and the absence of radioactive iodine (RAI) ablation therapy following surgery. In total, 49 patients were included in the study and all had been previously treated with total or near total thyroidectomy (with or without central neck dissection) and RAI, postoperatively. The Tg functional sensitivity was 1.0 ng/ml. The follow-up for patients was performed annually. During the median follow-up of 12.4 years after the rhTSH stimulation test, nine patients exhibited recurrence (18.4%). Of the nine patients, six exhibited sTg levels >2 ng/ml (positive result) and three exhibited levels <2 ng/ml (negative result). Relapse occurred at a mean of 5.9 years following the rhTSH stimulation test. The positive predictive value and negative predictive value (NPV) of positive sTg were 50 and 91.9%, respectively, with a sensitivity of 66.6% and a specificity of 85.0%. The rhTSH-stimulated Tg levels have a high NPV, allowing the identification of the patients who are free of the tumour. These results are consistent with the previously published data; however, to the best of our knowledge, this is the study with the longest follow-up duration after rhTSH stimulation. PMID:25663898

  13. Short-term adhesion and long-term biofouling testing of polydopamine and poly(ethylene glycol) surface modifications of membranes and feed spacers for biofouling control

    KAUST Repository

    Miller, Daniel J.

    2012-08-01

    Ultrafiltration, nanofiltration membranes and feed spacers were hydrophilized with polydopamine and polydopamine- g-poly(ethylene glycol) surface coatings. The fouling propensity of modified and unmodified membranes was evaluated by short-term batch protein and bacterial adhesion tests. The fouling propensity of modified and unmodified membranes and spacers was evaluated by continuous biofouling experiments in a membrane fouling simulator. The goals of the study were: 1) to determine the effectiveness of polydopamine and polydopamine- g-poly(ethylene glycol) membrane coatings for biofouling control and 2) to compare techniques commonly used in assessment of membrane biofouling propensity with biofouling experiments under practical conditions. Short-term adhesion tests were carried out under static, no-flow conditions for 1 h using bovine serum albumin, a common model globular protein, and Pseudomonas aeruginosa, a common model Gram-negative bacterium. Biofouling tests were performed in a membrane fouling simulator (MFS) for several days under flow conditions similar to those encountered in industrial modules with the autochthonous drinking water population and acetate dosage as organic substrate. Polydopamine- and polydopamine- g-poly(ethylene glycol)-modified membranes showed significantly reduced adhesion of bovine serum albumin and P. aeruginosa in the short-term adhesion tests, but no reduction of biofouling was observed during longer biofouling experiments with modified membranes and spacers. These results demonstrate that short-term batch adhesion experiments using model proteins or bacteria under static conditions are not indicative of biofouling, while continuous biofouling experiments showed that membrane surface modification by polydopamine and polydopamine- g-poly(ethylene glycol) is not effective for biofouling control. © 2012 Elsevier Ltd.

  14. Vanishing testes syndrome-related osteoporosis and high cardio-metabolic risk in an adult male with long term untreated hypergonadotropic hypogonadism.

    Science.gov (United States)

    Carsote, Mara; Capatina, Cristina; Valea, Ana; Dumitrascu, Anda

    2016-02-01

    The male hypogonadism-related bone mass loss is often under diagnosed. Peak bone mass is severely affected if the hypogonadism occurs during puberty and is left untreated. We present an interesting; almost bizarre case of a male with non-functional testes early during childhood and undiagnosed and untreated hypogonadism until his fifth decade of life. Forty six year male is referred for goitre, complaining of back pain. Phenotype suggested intersexuality: gynoid proportions, micropenis, no palpable testes into the scrotum, no facial or truncal hair. His medical history had been unremarkable until the previous year when primary hypothyroidism was diagnosed and levothyroxine replacement was initiated. Later, he was diagnosed with ischemic heart disease, with inaugural unstable angina. On admission, the testosterone was 0.2 ng/mL (normal: 1.7-7.8 ng/mL), FSH markedly increased (56 mUI/mL), with normal adrenal axis, and TSH (under thyroxine replacement). High bone turnover markers, and blood cholesterol, and impaired glucose tolerance were diagnosed. The testes were not present in the scrotum. Abdominal computed tomography suggested bilateral masses of 1.6 cm diameter within the abdominal fat that were removed but no gonadal tissue was confirmed histopathologically. Vanishing testes syndrome was confirmed. The central DXA showed lumbar bone mineral density of 0.905 g/cm2, Z-score of -2.9SD. The spine profile X-Ray revealed multiple thoracic vertebral fractures. Alendronate therapy together with vitamin D and calcium supplements and trans-dermal testosterone were started. Four decades of hypogonadism associate increased cardiac risk, as well as decreased bone mass and high fracture risk.

  15. 550 tests to support Tihange 2 and Doel 3 integrity assessment. Extensive research based on SCK-CEN's long-term expertise

    International Nuclear Information System (INIS)

    2014-01-01

    The article discusses the analyses that were performed in order to assess of the impact of the hydrogen flakes on the mechanical properties of the vessels of the Doel 3 and Tihange 2 nuclear power plants . Results from 550 tests shows no significant influence on the mechanical properties. Both reactors were given the green light by the regulator AFCN/FANC to restart operation. On specific request of the Belgian safety authorities, an interim research programme was set up in parallel to study the effects of irradiation on the material. The BR2 reactor is engaged for this research.

  16. Long-term environmental behaviour of radionuclides

    International Nuclear Information System (INIS)

    Brechignac, F.; Moberg, L.; Suomela, M.

    2000-04-01

    The radioactive pollution of the environment results from the atmospheric nuclear weapons testing (during the mid-years of twentieth century), from the development of the civilian nuclear industry and from accidents such as Chernobyl. Assessing the resulting radiation that humans might receive requires a good understanding of the long-term behaviour of radionuclides in the environment. This document reports on a joint European effort to advance this understanding, 3 multinational projects have been coordinated: PEACE, EPORA and LANDSCAPE. This report proposes an overview of the results obtained and they are presented in 6 different themes: i) redistribution in the soil-plant system, ii) modelling, iii) countermeasures, iv) runoff v) spatial variations, and vi) dose assessment. The long term behaviour of the radionuclides 137 Cs, 90 Sr and 239-240 Pu is studied through various approaches, these approaches range from in-situ experiments designed to exploit past contamination events to laboratory simulations. A broad scope of different ecosystems ranging from arctic and boreal regions down to mediterranean ones has been considered. (A.C.)

  17. Long-term environmental behaviour of radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Brechignac, F.; Moberg, L.; Suomela, M

    2000-04-01

    The radioactive pollution of the environment results from the atmospheric nuclear weapons testing (during the mid-years of twentieth century), from the development of the civilian nuclear industry and from accidents such as Chernobyl. Assessing the resulting radiation that humans might receive requires a good understanding of the long-term behaviour of radionuclides in the environment. This document reports on a joint European effort to advance this understanding, 3 multinational projects have been coordinated: PEACE, EPORA and LANDSCAPE. This report proposes an overview of the results obtained and they are presented in 6 different themes: (i) redistribution in the soil-plant system, (ii) modelling, (iii) countermeasures, (iv) runoff (v) spatial variations, and (vi) dose assessment. The long term behaviour of the radionuclides {sup 137}Cs, {sup 90}Sr and {sup 239-240}Pu is studied through various approaches, these approaches range from in-situ experiments designed to exploit past contamination events to laboratory simulations. A broad scope of different ecosystems ranging from arctic and boreal regions down to mediterranean ones has been considered. (A.C.)

  18. Long-term preservation of anammox bacteria.

    Science.gov (United States)

    Rothrock, Michael J; Vanotti, Matias B; Szögi, Ariel A; Gonzalez, Maria Cruz Garcia; Fujii, Takao

    2011-10-01

    Deposit of useful microorganisms in culture collections requires long-term preservation and successful reactivation techniques. The goal of this study was to develop a simple preservation protocol for the long-term storage and reactivation of the anammox biomass. To achieve this, anammox biomass was frozen or lyophilized at two different freezing temperatures (-60°C and in liquid nitrogen (-200°C)) in skim milk media (with and without glycerol), and the reactivation of anammox activity was monitored after a 4-month storage period. Of the different preservation treatments tested, only anammox biomass preserved via freezing in liquid nitrogen followed by lyophilization in skim milk media without glycerol achieved stoichiometric ratios for the anammox reaction similar to the biomass in both the parent bioreactor and in the freshly harvested control treatment. A freezing temperature of -60°C alone, or in conjunction with lyophilization, resulted in the partial recovery of the anammox bacteria, with an equal mixture of anammox and nitrifying bacteria in the reactivated biomass. To our knowledge, this is the first report of the successful reactivation of anammox biomass preserved via sub-zero freezing and/or lyophilization. The simple preservation protocol developed from this study could be beneficial to accelerate the integration of anammox-based processes into current treatment systems through a highly efficient starting anammox biomass.

  19. Sleep facilitates long-term face adaptation.

    Science.gov (United States)

    Ditye, Thomas; Javadi, Amir Homayoun; Carbon, Claus-Christian; Walsh, Vincent

    2013-10-22

    Adaptation is an automatic neural mechanism supporting the optimization of visual processing on the basis of previous experiences. While the short-term effects of adaptation on behaviour and physiology have been studied extensively, perceptual long-term changes associated with adaptation are still poorly understood. Here, we show that the integration of adaptation-dependent long-term shifts in neural function is facilitated by sleep. Perceptual shifts induced by adaptation to a distorted image of a famous person were larger in a group of participants who had slept (experiment 1) or merely napped for 90 min (experiment 2) during the interval between adaptation and test compared with controls who stayed awake. Participants' individual rapid eye movement sleep duration predicted the size of post-sleep behavioural adaptation effects. Our data suggest that sleep prevented decay of adaptation in a way that is qualitatively different from the effects of reduced visual interference known as 'storage'. In the light of the well-established link between sleep and memory consolidation, our findings link the perceptual mechanisms of sensory adaptation--which are usually not considered to play a relevant role in mnemonic processes--with learning and memory, and at the same time reveal a new function of sleep in cognition.

  20. Pumping tests in nonuniform aquifers - The radially symmetric case

    Science.gov (United States)

    Butler, J.J.

    1988-01-01

    Traditionally, pumping-test-analysis methodology has been limited to applications involving aquifers whose properties are assumed uniform in space. This work attempts to assess the applicability of analytical methodology to a broader class of units with spatially varying properties. An examination of flow behavior in a simple configuration consisting of pumping from the center of a circular disk embedded in a matrix of differing properties is the basis for this investigation. A solution describing flow in this configuration is obtained through Laplace-transform techniques using analytical and numerical inversion schemes. Approaches for the calculation of flow properties in conditions that can be roughly represented by this simple configuration are proposed. Possible applications include a wide variety of geologic structures, as well as the case of a well skin resulting from drilling or development. Of more importance than the specifics of these techniques for analysis of water-level responses is the insight into flow behavior during a pumping test that is provided by the large-time form of the derived solution. The solution reveals that drawdown during a pumping test can be considered to consist of two components that are dependent and independent of near-well properties, respectively. Such an interpretation of pumping-test drawdown allows some general conclusions to be drawn concerning the relationship between parameters calculated using analytical approaches based on curve-matching and those calculated using approaches based on the slope of a semilog straight line plot. The infinite-series truncation that underlies the semilog analytical approaches is shown to remove further contributions of near-well material to total drawdown. In addition, the semilog distance-drawdown approach is shown to yield an expression that is equivalent to the Thiem equation. These results allow some general recommendations to be made concerning observation-well placement for pumping

  1. Long-term cryogenic space storage system

    Science.gov (United States)

    Hopkins, R. A.; Chronic, W. L.

    1973-01-01

    Discussion of the design, fabrication and testing of a 225-cu ft spherical cryogenic storage system for long-term subcritical applications under zero-g conditions in storing subcritical cryogens for space vehicle propulsion systems. The insulation system design, the analytical methods used, and the correlation between the performance test results and analytical predictions are described. The best available multilayer insulation materials and state-of-the-art thermal protection concepts were applied in the design, providing a boiloff rate of 0.152 lb/hr, or 0.032% per day, and an overall heat flux of 0.066 Btu/sq ft hr based on a 200 sq ft surface area. A six to eighteen month cryogenic storage is provided by this system for space applications.

  2. Prediction of long-term creep curves

    International Nuclear Information System (INIS)

    Oikawa, Hiroshi; Maruyama, Kouichi

    1992-01-01

    This paper aims at discussing how to predict long-term irradiation enhanced creep properties from short-term tests. The predictive method based on the θ concept was examined by using creep data of ferritic steels. The method was successful in predicting creep curves including the tertiary creep stage as well as rupture lifetimes. Some material constants involved in the method are insensitive to the irradiation environment, and their values obtained in thermal creep are applicable to irradiation enhanced creep. The creep mechanisms of most engineering materials definitely change at the athermal yield stress in the non-creep regime. One should be aware that short-term tests must be carried out at stresses lower than the athermal yield stress in order to predict the creep behavior of structural components correctly. (orig.)

  3. Evaluation of the Long-Term Performance of Titanate Ceramics for Immobilization of Excess Weapons Plutonium: Results from Pressurized Unsaturated Flow and Single Pass Flow-Through Testing

    International Nuclear Information System (INIS)

    BP McGrail; HT Schaef; JP Icenhower; PF Martin; RD Orr; VL Legore

    1999-01-01

    This report summarizes our findings from pressurized unsaturated flow (PUF) and single-pass flow-through (SPFT) experiments to date. Results from the PUF test of a Pu-bearing ceramic with enclosing surrogate high-level waste glass show that the glass reacts rapidly to alteration products. Glass reaction causes variations in the solution pH in contact with the ceramic materials. We also document variable concentrations of Pu in solution, primarily in colloidal form, which appear to be related to secular variations in solution composition. The apparent dissolution rate of the ceramic waste form, based on Ba concentrations in the effluent, is estimated at le 10 -5 g/(m 2 · d). Pu-bearing colloids were recovered in the size range of 0.2 to 2 microm, but it is not clear that such entities would be transported in a system that is not advective-flow dominated. Results from SPFT experiments give information on the corrosion resistance of two surrogate Pu-ceramics (Ce-pyrochlore and Ce-zirconolite) at 90 C over a pH range of 2 to 12. The two ceramics were doped with minor quantities (approximately0.1 mass%) of MoO 3 , so that concentrations of Mo in the effluent solution could be used to monitor the reaction behavior of the materials. The data obtained thus far from experiments with durations up to 150 d do not conclusively prove that the solid-aqueous solution systems have reached steady-state conditions. Therefore, the dissolution mechanism cannot be determined. Apparent dissolution rates of the two ceramic materials based on Ce, Gd, and Mo concentrations in the effluent solutions from the SPFT are nearly identical and vary between 1.1 to 8.5 x 10 -4 g/(m 2 · d). In addition, the data reveal a slightly amphoteric dissolution behavior, with a minimum apparent rate at pH = 7 to 8, over the pH range examined. Results from two related ceramic samples suggest that radiation damage can have a measurable effect on the dissolution of titanium-based ceramics. The rare earth

  4. A novel energy regeneration system for emulsion pump tests

    Energy Technology Data Exchange (ETDEWEB)

    Yilei, Li; Zhencai, Zhu; Guohua, Cao [China University of Mining and Technology, Xuzhou (China); Guoan, Chen [Command Academy of the Corps of Engineers, Xuzhou (China)

    2013-04-15

    A novel energy regeneration system based on cylinders and a rectifier valve for emulsion pump tests is presented and studied. The overall structure and working principles of this system are introduced. Both simulation and experiments are carried out to investigate the energy regeneration feasibility and capability of this novel system. The simulation and experimental results validate that this system is able to save energy and satisfy the test requirement. The energy recovery coefficient and overall energy regeneration coefficient of the test bench are 0.785 and 0.214, respectively. Measures to improve these two coefficients are also given accordingly after analysis of power loss. This novel system brings a new method of energy regeneration for emulsion pump tests.

  5. Combined pump and marking tests for determining protection zones

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Brauns, J.

    1982-02-01

    Under difficult conditions the determination of the protection area II on the basis of Mear pump tests becomes uncertain. The report shows how in such cases the results of supplementary marking tests can establish a more accurate finding. The execution of combined pump and marking tests enables us to check data gained on a theoretical basis and possibly alter these. This method is described in an example, in which certain hydrogeological conditions and rival interests of ground water protection prevail on the one side and utilization of land on the other side. A general tendency exists to take the utmost protective measure in safeguarding ground water, however in cases of collision of interests the boundary of the protective area should be optimized. Supplementary marking tests can be of great significance.

  6. Risk based requirements for long term stewardship: A proof-of-principle analysis of an analytic method tested on selected Hanford locations

    International Nuclear Information System (INIS)

    Jarvis, T.T.; Andrews, W.B.; Buck, J.W.

    1998-03-01

    Since 1989, the Department of Energy's (DOE) Environmental Management (EM) Program has managed the environmental legacy of US nuclear weapons production, research and testing at 137 facilities in 31 states and one US territory. The EM program has conducted several studies on the public risks posed by contaminated sites at these facilities. In Risks and the Risk Debate [DOE, 1995a], the Department analyzed the risks at sites before, during, and after remediation work by the EM program. The results indicated that aside from a few urgent risks, most hazards present little inherent risk because physical and active site management controls limit both the releases of site contaminants, and public access to these hazards. Without these controls, these sites would pose greater risks to the public. Past risk reports, however, provided little information about post-cleanup risk, primarily because of uncertainty about future site uses and site characteristics at the end of planned cleanup activities. This is of concern because in many cases current cleanup technologies, and remedies, will last a shorter period of time than the waste itself and the resulting contamination will remain hazardous

  7. Risk Based Requirements for Long Term Stewardship: A Proof-of-Principle Analysis of an Analytic Method Tested on Selected Hanford Locations

    Energy Technology Data Exchange (ETDEWEB)

    GM Gelston; JW Buck; LR Huesties; MS Peffers; TB Miley; TT Jarvis; WB Andrews

    1998-12-03

    Since 1989, the Department of Energy's (DOE) Environmental Management (EM) Program has managed the environmental legacy of US nuclear weapons production research and testing at 137 facilities in 31 states and one US territory. The EM program has conducted several studies on the public risks posed by contaminated sites at these facilities. In Risks and the Risk Debate DOE, 1995a, the Department analyzed the risks at sites before, during, and after remediation work by the EM program. The results indicated that aside from a few urgent risks, most hazards present little inherent risk because physical and active site management controls limit both the releases of site contaminants, and public access to these hazards. Without these controls, these sites would pose greater risks to the public. Past risk reports, however, provided little irdiormation about post- cleanup risk, primarily because of uncertainty about fiture site uses and site characteristics at the end of planned cleanup activities. This is of concern because in many cases current cleanup technologies, and remedies, will last a shorter period of time than the waste itself and the resulting contamination will remain hazardous.

  8. Rapid internationalization and long-term performance: The knowledge link

    OpenAIRE

    García-García, Raquel; García-Canal, Esteban; Guillén, Mauro F.

    2017-01-01

    Drawing on the knowledge-based view and organizational learning theory, we develop and test a set of hypotheses to provide a first attempt at analyzing the effect of speed of internationalization on long-term performance. Using a panel-data sample of Spanish listed firms (1986-2010), we find that there is an inverted U-shaped relationship between speed of internationalization and long-term performance. We also find that whereas technological knowledge steepens this relationship, the diversity...

  9. Long-term functional health status and exercise test variables for patients with pulmonary atresia with intact ventricular septum: A Congenital Heart Surgeons Society study

    Science.gov (United States)

    Karamlou, Tara; Poynter, Jeffrey A.; Walters, Henry L.; Rhodes, Jonathan; Bondarenko, Igor; Pasquali, Sara K.; Fuller, Stephanie M.; Lambert, Linda M.; Blackstone, Eugene H.; Jacobs, Marshall L.; Duncan, Kim; Caldarone, Christopher A.; Williams, William G.; McCrindle, Brian W.

    2013-01-01

    Background A bias favoring biventricular (BV) repair exists regarding choice of repair pathway for patients with pulmonary atresia with intact ventricular septum (PAIVS). We sought to determine the implications of moving borderline candidates down a BV route in terms of late functional health status (FHS) and exercise capacity (EC). Methods Between 1987 and 1997, 448 neonates with PAIVS were enrolled in a multi-institutional study. Late EC and FHS were assessed following repair (mean 14 years) using standardized exercise testing and 3 validated FHS instruments. Relationships between FHS, EC, morphology, and 3 end states (ie, BV, univentricular [UV], or 1.5-ventricle repair [1.5V]) were evaluated. Results One hundred two of 271 end state survivors participated (63 BV, 25 UV, and 14 1.5V). Participants had lower FHS scores in domains of physical functioning (P < .001) compared with age- and sex-matched normal controls, but scored significantly higher in nearly all psychosocial domains. EC was higher in 1.5V-repair patients (P = .02), whereas discrete FHS measures were higher in BV-repair patients. Peak oxygen consumption was low across all groups, and was positively correlated with larger initial tricuspid valve z-score (P < .001), with an enhanced effect within the BV-repair group. Conclusions Late patient-perceived physical FHS and measured EC are reduced, regardless of PAIVS repair pathway, with an important dichotomy whereby patients with PAIVS believe they are doing well despite important physical impediments. For those with smaller initial tricuspid valve z-score, achievement of survival with BV repair may be at a cost of late deficits in exercise capacity, emphasizing that better outcomes may be achieved for borderline patients with a 1.5V- or UV-repair strategy. PMID:23374986

  10. Test report for the run-in acceptance testing of the hydrogen mitigation retrieval Pump-3

    International Nuclear Information System (INIS)

    Berglin, B.G.; Nash, Ch.R.

    1997-01-01

    This report will provide the findings of the demonstration test conducted on the Double-Shell Tank (DST) 241-SY-101 HMR Pump-3 in accordance with WHC-SDWM-TP-434 ''Test plan for run-in acceptance testing of hydrogen mitigation/retrieval pump-3'' at the 400 Area Maintenance and Storage Facility (MASF) building from 7 June 1996 through 30 July 1996 per work package 4A-96-92/W. The DST 241-SY-101 hydrogen mitigation retrieval Pump-3 is a 200-HP submersible electric driven pump that has been modified for use in the DST 241-SY-101 containing mixed waste located in the 200W area. The pump has a motor driven rotation mechanism that allows the pump column to rotate through 355 degree. Prior to operation, pre-operational checks were performed which included loop calibration grooming and alignment of instruments, learning how plumb HMR-3 assembly hung in a vertical position and bump test of the motor to determine rotation direction. The pump was tested in the MASF Large Diameter Cleaning Vessel (LDCV) with process water at controlled temperatures and levels. In addition, the water temperature of the cooling water to the motor oil heat exchanger was recorded during testing. A 480-volt source powered a Variable Frequency Drive (VFD). The VFD powered the pump at various frequencies and voltages to control speed and power output of the pump. A second VFD powered the oil cooling pump. A third VFD was not available to operate the rotational drive motor during the 72 hour test, so it was demonstrated as operational before and after the test. A Mini Acquisition and Control System (Mini-DACS) controls pump functions and monitoring of the pump parameters. The Mini-DACS consists of three computers, software and some Programmable Logic Controllers (PLC). Startup and shutdown of either the pump motor or the oil cooling pump can be accomplished by the Mini-DACS. When the pump was in operation, the Mini-DACS monitors automatically collects data electronically. However, some required data

  11. Financing long term liabilities (Germany)

    International Nuclear Information System (INIS)

    2003-01-01

    charges and fees levied from the waste producers. Altogether, financial resources for decommissioning are needed for the following steps: the post-operational phase in which the facility is prepared for dismantling after its final shut-down, dismantling of the radioactive part of the facility, management, storage and disposal of the radioactive waste, restoration of the site, licensing and regulatory supervision of all these steps. Additional means are necessary for the management, storage and disposal of the spent fuel. The way in which the availability of financial resources is secured differs between public owned installations and installations of the private power utilities. In Germany, past practices has resulted in singular contaminated sites of limited extent, mainly during the first half of the 20. century. Those contaminated sites have been or are being cleaned up and redeveloped. In large areas of Saxony and Thuringia, the geological formations permitted the surface and underground mining of Uranium ore. Facilities of the former Soviet-German WISMUT Ltd. where ore was mined and processed from 1946 until the early 1990's can be found at numerous sites. In the course of the re-unification of Germany, the soviet shares of the WISMUT were taken over by the Federal Republic of Germany and the closure of the WISMUT facilities was initiated. In that phase the extent of the damages to the environment and of the necessary remediation work became clear. All mining and milling sites are now closed and are under decommissioning. A comprehensive remediation concept covers all WISMUT sites. Heaps and mill-tailing ponds are transferred into a long-term stable condition. The area of the facilities to be remediated amounts to more than 30 km 2 . Heaps cover a total area of ca. 15,5 km 2 , tailing ponds in which the tailings resulting from the Uranium production are stored as sludges cover 6,3 km 2 ). In total, the remediation issues are very complex and without precedent. The

  12. Maintenance management during long-term stop of JRR-3

    International Nuclear Information System (INIS)

    Matsui, Yutaka; Suwa, Masayuki; Wada, Shigeru

    2016-01-01

    JRR-3 has been continuing its stop state for more than 5 years as of FY2015 after stopping the use operation of the reactor in November 2010. Different responses are required in the maintenance management for operation resumption, compared with those in normal operation. This paper introduces part of the maintenance managements that are performed during long-term stop. The water qualities of primary coolant and secondary coolant are controlled by measuring pH and conductivity, and the prevention of crevice corrosion of equipment is performed. In the management of pumps for coolant circulation, vibration measurement is performed to confirm that there are no signs of abnormality. As the management of the core structure, the bend measurement of beryllium reflector is performed to confirm that there is no hindrance to operation resumption, and the visual inspection of high burnup fuel elements is performed to confirm that abnormality has not occurred. As for the management of monitoring equipment, the equipment required in shutdown period is subjected to calibration work, and the equipment required in operation period is subjected to soundness check based on the results of cooling system operation. As the functional maintenance of the cooling system, cooling system operating test and 10-day continuous operation of the cooling system are monthly performed to confirm the soundness of equipment. In addition, the competence maintenance and capacity improvement of operators are performed through the cooling system operation and reactor simulator training. (A.O.)

  13. Alternative method of inservice hydraulic testing of difficult to test pumps

    International Nuclear Information System (INIS)

    Stockton, N.B.; Shangari, S.

    1994-01-01

    The pump test codes require that system resistance be varied until the independent variable (either the pump flow rate or differential pressure) equals its reference value. Variance from this fixed reference value is not specifically allowed. However, the design of many systems makes it impractical to set the independent variable to an exact value. Over a limited range of pump operation about the fixed reference value, linear interpolation between two points of pump operation can be used to accurately determine degradation at the reference value without repeating reference test conditions. This paper presents an overview of possible alternatives for hydraulic testing of pumps and a detailed discussion of the linear interpolation method. The approximation error associated with linear interpolation is analyzed. Methods to quantify and minimize approximation error are presented

  14. ComfortPower - System improvements and long-term evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Silversand, Fredrik [Catator AB, Lund (Sweden)

    2011-11-15

    Catator has previously developed a novel heating system abbreviated ComfortPower in a RandD-programme supported by Catator, Swedish Gas Centre (SGC), Swedish Defence Materiel Administration (FMV), Skanska, Nibe and Alfa Laval. The ComfortPower unit comprises a multi fuel reformer system tied to a high-temperature polymer electrolyte fuel cell (HT-PEM) and a heat pump system. Since the residual heat from the fuel cell system can be utilized in a very effective way, it is possible to reach high thermal efficiencies. Indeed, the thermal efficiency in the unit has previously been shown to reach values as high as 175 - 200 % based on the lower heating value of the fuel. In addition to heat, ComfortPower can supply comfort cooling and surplus electricity. This project phase has focused on the following elements: 1. System improvements to further enhance the efficiency with existing fuel cell (HT-PEM). 2. System simplifications (e.g. DC-compressor system) to manage issues with start-up currents. 3. Tests with biogas qualities (various levels of CO{sub 2}) and biogas/air. 4. Long-term test with biogas quality (upgraded biogas). 5. Additional tests with liquid fuels (alcohols and diesel). 6. Map the need for cooling and heating in various applications. 7. Investigate how ComfortPower can reduce the primary energy consumption and reduce the environmental impact. 8. Study the possibility with a SOFC-based system with internal reforming. It was found that the Optiformer technology can be used to derive a suitable reformate gas for the HT-PEM unit from a wide range of fuels. Even if operation with fuel gases is the natural choice in most cases, it is possible also to use alcohols and other liquid fuels (e.g. in Campus applications). The heat pump system was equipped with a 24 V DC-compressor provided by Nibe. The compressor could be directly powered by the accumulator system and start-up currents, harmful to the inverter, could be avoided. Some improvements were made on the

  15. A Long-term Plan for Kalk

    DEFF Research Database (Denmark)

    2017-01-01

    In this case, the author demonstrates together with the owner-manager of KALK A/S, Mr Rasmus Jorgensen, how to use the Family Business Map to frame a constructive discussion about long-term planning. The Family Business Map is a tool for long-term planning in family firms developed by Professor...

  16. Virtual Models of Long-Term Care

    Science.gov (United States)

    Phenice, Lillian A.; Griffore, Robert J.

    2012-01-01

    Nursing homes, assisted living facilities and home-care organizations, use web sites to describe their services to potential consumers. This virtual ethnographic study developed models representing how potential consumers may understand this information using data from web sites of 69 long-term-care providers. The content of long-term-care web…

  17. Construction and testing of a double acting bellows liquid helium pump

    International Nuclear Information System (INIS)

    Burns, W.A.; Green, M.A.; Ross, R.R.; Van Slyke, H.

    1980-05-01

    The double acting reciprocating bellows liquid helium pump built and tested at the Lawrence Berkeley Laboratory is described. The pump is capable of delivering 50 gs -1 of liquid helium to supply the two-phase cooling sytem for a large superconducting magnet. The pump is driven by a torque motor at room temperature; the reciprocating motion is transmitted to the pump through a shaft which operates between room temperature and 4 0 K. The design details of this liquid helium pump are presented. The helium pump has operated in a helium bath and in pumped forced flow helium circuits. The results of these experimental tests are presented in this report

  18. Containment long-term operational integrity

    International Nuclear Information System (INIS)

    Sammataro, R.F.

    1990-01-01

    Periodic integrated leak rate tests are required to assure that containments continue to meet allowable leakage limits. Although overall performance has been quite good to date, several major containment aging and degradation mechanisms have been identified. Two pilot plant life extension (PLEX) studies serve as models for extending the operational integrity of present containments for light-water cooled nuclear power plants in the United States. One study is for a Boiling-Water Reactor (BWR) and the second is for a Pressurized-Water Reactor (PWR). Research and testing programs for determining the ultimate pressure capacity and failure mechanisms for containments under severe loading conditions and studies for extending the life of current plants beyond the present 40-year licensed lifetime are under way. This paper presents an overview of containment designs in the United States. Also presented are a discussion of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) and regulatory authority requirements for the design, construction, inservice inspection, leakage testing and repair of steel and concrete containments. Findings for containments from the pilot PLEX studies and continuing containment integrity research and testing programs are discussed. The ASME Code and regulatory requirements together with recommendations from the PLEX studies and containment integrity research and testing provide a basis for continued containment long-term operational integrity. (orig./GL)

  19. Tests of dry mechanical forepumps for use in the ITER vacuum pumping system

    International Nuclear Information System (INIS)

    Kirchhof, U.; Kammerer, B.; Perinic, D.

    1995-04-01

    This report is a description of the design and construction of FORTE (Forepumps Test Facility) which has been built in order to enable testing of the pumping speeds of prototypical mechanical forepumps connected in series, as proposed for the ITER forepump system. Three NORMETEX pumps (1300, 600, 60 m 3 /h) and one METAL BELLOWS pump (6m 3 /h) have been integrated into the test bench. Measurements of the pumping characteristics were performed, both with the single pumps and with trains of series connected pumps, using the gases N 2 , H 2 , D 2 , He as well as ITER typical gas mixture. The results of the tests are presented. (orig.)

  20. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  1. How effective and cost-effective are innovative combinatorial technologies and practices for supporting older people with long-term conditions to remain well in the community? An evaluation protocol for an NHS Test Bed in North West England.

    Science.gov (United States)

    Varey, Sandra; Hernández, Alejandra; Palmer, Tom M; Mateus, Céu; Wilkinson, Joann; Dixon, Mandy; Milligan, Christine

    2018-02-28

    The Lancashire and Cumbria Innovation Alliance (LCIA) Test Bed is a partnership between the National Health Service in England, industry (led by Philips) and Lancaster University. Through the implementation of a combination of innovative health technologies and practices, it aims to determine the most effective and cost-effective ways of supporting frail older people with long-term conditions to remain well in the community. Among the Test Bed's objectives are to improve patient activation and the ability of older people to self-care at home, reduce healthcare system utilisation, and deliver increased workforce productivity. Patients aged 55 years and over are recruited to four cohorts defined by their risk of hospital admission, with long-term conditions including chronic obstructive pulmonary disease, dementia, diabetes and heart failure. The programme is determined on an individual basis, with a range of technologies available. The evaluation is adopting a two-phase approach: phase 1 includes a bespoke patient survey and a mass matched control analysis; and phase 2 is using observational interviews with patients, and weekly diaries, action learning meetings and focus groups with members of staff and other key stakeholders. Phase 1 data analysis consists of a statistical evaluation of the effectiveness of the programme. A health economic analysis of its costs and associated cost changes will be undertaken. Phase 2 data will be analysed thematically with the aid of Atlas.ti qualitative software. The evaluation is located within a logic model framework, to consider the processes, management and participation that may have implications for the Test Bed's success. The LCIA Test Bed evaluation has received ethical approval from the Health Research Authority and Lancaster University's Faculty of Health and Medicine Research Ethics Committee. A range of dissemination methods are adopted, including deliberative panels to validate findings and develop outcomes for policy

  2. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5489. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''N''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  3. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid M

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5073. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''M''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  4. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-11-09

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  5. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  6. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-12-13

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5073. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''M''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  7. Description of comprehensive pump test change to ASME OM code, subsection ISTB

    International Nuclear Information System (INIS)

    Hartley, R.S.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Operations and Maintenance (OM) Main Committee and Board on Nuclear Codes and Standards (BNCS) recently approved changes to ASME OM Code-1990, Subsection ISTB, Inservice Testing of Pumps in Light-Water Reactor Power Plants. The changes will be included in the 1994 addenda to ISTB. The changes, designated as the comprehensive pump test, incorporate a new, improved philosophy for testing safety-related pumps in nuclear power plants. An important philosophical difference between the open-quotes old codeclose quotes inservice testing (IST) requirements and these changes is that the changes concentrate on less frequent, more meaningful testing while minimizing damaging and uninformative low-flow testing. The comprehensive pump test change establishes a more involved biannual test for all pumps and significantly reduces the rigor of the quarterly test for standby pumps. The increased rigor and cost of the biannual comprehensive tests are offset by the reduced cost of testing and potential damage to the standby pumps, which comprise a large portion of the safety-related pumps at most plants. This paper provides background on the pump testing requirements, discusses potential industry benefits of the change, describes the development of the comprehensive pump test, and gives examples and reasons for many of the specific changes. This paper also describes additional changes to ISTB that will be included in the 1994 addenda that are associated with, but not part of, the comprehensive pump test

  8. Testing social acoustic memory in rats: effects of stimulus configuration and long-term memory on the induction of social approach behavior by appetitive 50-kHz ultrasonic vocalizations.

    Science.gov (United States)

    Wöhr, Markus; Schwarting, Rainer K W

    2012-09-01

    Rats emit distinct types of ultrasonic vocalizations (USVs), which serve as situation-dependent affective signals. In appetitive situations, such as rough-and-tumble-play, high-frequency 50-kHz USVs occur, whereas low-frequency 22-kHz USVs can be observed in aversive situations, such as social defeat. USVs serve distinct communicative functions and induce call-specific behavioral responses in the receiver. While aversive 22-kHz USVs serve as alarm calls and induce behavioral inhibition, appetitive 50-kHz USVs have a pro-social communicative function and elicit social approach behavior, supporting the notion that they serve as social contact calls to (re)establish or maintain contact among conspecifics. The aim of the present study was to use the rat's ability to communicate in the ultrasonic range via high-frequency 50-kHz USVs in order to develop a test for social acoustic memory in rats with relevance for human verbal memory. Verbal learning and memory is among the seven cognitive domains identified as commonly deficient in human schizophrenia patients, but particularly difficult to model. We therefore tested whether the induction of social approach behavior by playback of appetitive 50-kHz USVs is dependent on (1) acoustic stimulus configuration and (2) social long-term memory, and whether (3) social long-term memory effects can be blocked by the administration of scopolamine, a muscarinic acetylcholine antagonist producing amnesia. Results show that social approach behavior in response to playback of natural 50-kHz USVs depends on acoustic stimulus configuration and occurs only when sound energy is concentrated to a critical frequency band in the ultrasonic range. Social approach behavior was detected during the first exposure to playback of 50-kHz USVs, whereas no such response was observed during the second exposure 1week later, indicating a stable memory trace. In contrast, when memory formation was blocked by i.p. administration of scopolamine (0.5mg/kg or

  9. Long term wet spent nuclear fuel storage

    International Nuclear Information System (INIS)

    1987-04-01

    The meeting showed that there is continuing confidence in the use of wet storage for spent nuclear fuel and that long-term wet storage of fuel clad in zirconium alloys can be readily achieved. The importance of maintaining good water chemistry has been identified. The long-term wet storage behaviour of sensitized stainless steel clad fuel involves, as yet, some uncertainties. However, great reliance will be placed on long-term wet storage of spent fuel into the future. The following topics were treated to some extent: Oxidation of the external surface of fuel clad, rod consolidation, radiation protection, optimum methods of treating spent fuel storage water, physical radiation effects, and the behaviour of spent fuel assemblies of long-term wet storage conditions. A number of papers on national experience are included

  10. Industrial Foundations as Long-Term Owners

    DEFF Research Database (Denmark)

    Thomsen, Steen; Poulsen, Thomas; Børsting, Christa Winther

    Short-termism has become a serious concern for corporate governance, and this has inspired a search for institutional arrangements to promote long-term decision-making. In this paper, we call attention to long-term ownership by industrial foundations, which is common in Northern Europe but little...... known in the rest of the world. We use a unique Danish data set to document that industrial foundations are long-term owners that practice long-term governance. We show that foundation ownership is highly stable compared to other ownership structures. Foundation-owned companies replace managers less...... frequently. They have conservative capital structures with low financial leverage. They score higher on an index of long-termism in finance, investment, and employment. They survive longer. Overall, our paper supports the hypothesis that corporate time horizons are influenced by ownership structures...

  11. Coping with PH over the Long Term

    Science.gov (United States)

    ... a job, a volunteer commitment, or even a hobby can take a toll on long-term survivors ... people find solace in meditation, faith, humor, writing, hobbies and more. Find an outlet that you enjoy ...

  12. Long term effects of radiation in man

    International Nuclear Information System (INIS)

    Tso Chih Ping; Idris Besar

    1984-01-01

    An overview of the long term effects of radiation in man is presented, categorizing into somatic effects, genetic effects and teratogenic effects, and including an indication of the problems that arise in their determination. (author)

  13. Long term liquidity analysis of the firm

    Directory of Open Access Journals (Sweden)

    Jaroslav Gonos

    2009-09-01

    Full Text Available Liquidity control is a very difficult and important function. If the business is not liquid in the long term, it is under threatof bankruptcy, and on the other hand surplus of the cash in hand threaten its future efficiency, because the cash in hand is a sourceof only limited profitability. Long term liquidity is related to the ability of the short term and long term liabilities payment. Articleis trying to point out to the monitoring and analyzing of the long term liquidity in the concrete business, in this case the printing industrycompany. Hereby at the end of the article mentioned monitored and analyzed liquidity is evaluated in the five years time period.

  14. Long Term Care Minimum Data Set (MDS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Long-Term Care Minimum Data Set (MDS) is a standardized, primary screening and assessment tool of health status that forms the foundation of the comprehensive...

  15. Sleep facilitates long-term face adaptation

    OpenAIRE

    Ditye, Thomas; Javadi, Amir Homayoun; Carbon, Claus-Christian; Walsh, Vincent

    2013-01-01

    Adaptation is an automatic neural mechanism supporting the optimization of visual processing on the basis of previous experiences. While the short-term effects of adaptation on behaviour and physiology have been studied extensively, perceptual long-term changes associated with adaptation are still poorly understood. Here, we show that the integration of adaptation-dependent long-term shifts in neural function is facilitated by sleep. Perceptual shifts induced by adaptation to a distorted imag...

  16. Marijuana effects on long-term memory assessment and retrieval.

    Science.gov (United States)

    Darley, C F; Tinklenberg, J R; Roth, W T; Vernon, S; Kopell, B S

    1977-05-09

    The ability of 16 college-educated male subjects to recall from long-term memory a series of common facts was tested during intoxication with marijuana extract calibrated to 0.3 mg/kg delta-9-tetrahydrocannabinol and during placebo conditions. The subjects' ability to assess their memory capabilities was then determined by measuring how certain they were about the accuracy of their recall performance and by having them predict their performance on a subsequent recognition test involving the same recall items. Marijuana had no effect on recall or recognition performance. These results do not support the view that marijuana provides access to facts in long-term storage which are inaccessible during non-intoxication. During both marijuana and placebo conditions, subjects could accurately predict their recognition memory performance. Hence, marijuana did not alter the subjects' ability to accurately assess what information resides in long-term memory even though they did not have complete access to that information.

  17. Fiscal 1999 geothermal energy development promotion survey. Survey of Akinomiya area (Long-term spurt test report - 1/2); 1999 nendo chinetsu kaihatsu sokushin chosa Akinomiya chiiki chosa hokokusho. 1/2. Choki funshutsu shiken

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-01-01

    A long-term survey was conducted on the spurting properties and fluid properties of geothermal fluids, when boreholes N9-AY-3 and N10-AY-8 were used as spurting wells and N8-AY-1, N10-AY-6, and N10-AY-7 as reinjection wells. Conducted or investigated were pH, electric conductivity, chlorine concentration determination, static temperature/pressure logging, PTS (pressure, temperature, spinner flowmeter) logging with wells spurting, buildup test, sampler logging with wells spurting, fluid property survey, tracer test, and borehole N10-AY-8 pulsation with fume spurting. It was then found that the maximum spurting capacity of borehole N9-AY-3 was 65.7t/h in steam and 90.8t/h in thermal water at a pit mouth pressure of 1.30MPaG. Some decrease was detected for approximately one month after the start of spurting, but it was concluded that there would be no further decrease thereafter. The maximum spurting capacity of borehole N10-AY-8 was 10.4t/h in steam and 8.9t/h in thermal water at a pit mouth pressure of 0.24MPaG. Some reduction was detected in the flow of steam and in fluid enthalpy after the start of spurting, and it was inferred that there would be still further reduction after continual spurting. (NEDO)

  18. 77 FR 8178 - Test Procedures for Central Air Conditioners and Heat Pumps: Public Meeting

    Science.gov (United States)

    2012-02-14

    .... EERE-2010-BT-TP-0038] Test Procedures for Central Air Conditioners and Heat Pumps: Public Meeting... methodologies and gather comments on testing residential central air conditioners and heat pumps designed to use... residential central air conditioners and heat pumps that are single phase with rated cooling capacities less...

  19. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix

  20. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid Q

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix

  1. Long-term effects of islet transplantation.

    Science.gov (United States)

    Holmes-Walker, D Jane; Kay, Thomas W H

    2016-10-01

    Islet transplantation has made great progress in recent years. This is a remarkable technical feat but raises the question of what the long-term benefits and risks are for type I diabetes recipients. Graft survival continues to improve, and recent multicenter studies show that islet transplantation is particularly effective to prevent hypoglycemic events even in those who do not become insulin-independent and to achieve excellent glycemic control. Concerns include histocompatability leucocyte antigen (HLA) sensitization and other risks including from immunosuppression that islet transplantation shares with other forms of allotransplantation. Reversal of hypoglycemia unawareness and protection from severe hypoglycemia events are two of the main benefits of islet transplantation and they persist for the duration of graft function. Islet transplantation compares favorably with other therapies for those with hypoglycemia unawareness, although new technologies have not been tested head-to-head with transplantation. HLA sensitization increases with time after transplantation especially if immunosuppression is ceased and is a risk for those who may require future transplantation as well as being associated with loss of graft function.

  2. Determination of Functional Capabilities, the Level of Physical Performance and the State of Main Physiological Body Systems in the First Hours after the Accomplishment of Long-term Space Flights ("Field Test")

    Science.gov (United States)

    Kozlovskaya, Inesa; Tomilovskaya, Elena; Rukavishnikov, Ilya; Kitov, Vladimir; Reschke, Millard; Kofman, Igor

    2014-01-01

    Long-term stay in weightlessness is accompanied by alterations in the activity of main physiological body systems including sensory-motor, skeletal-muscular disturbances and cardiovascular deconditioning. However, up to now, there are no data on the state and level of functional performance of cosmonauts/astronauts directly after flight, nor are there data to help define the dynamic recovery of functional characteristics and work efficiency which are greatly needed to provide the safety and planning of their activity once they reach space objects. The Russian and American scientists are currently engaged in a joint experiment known as the "Field Test" with the goal of studying the functional performance and the state of main physiological body systems directly after landing and their temporal recovery dynamics. The functional performance is identified during the test by temporal characteristics of the movements of spatial translation, the stability of the vertical stance for 3.5 min, and the kinematic characteristics of walking - non-complicated and complicated. The following characteristics are identified as physiological characteristics of the test: a) orthostatic tolerance during stand test, b) back muscle tone; c) vertical stability - by characteristics of the correction responses to unexpected perturbations of the vertical stance, and d) support reactions during the performance of the full battery of tests. To date, a pilot version of the "Field Test" has been conducted with participation from four Russian cosmonauts. The results of studies have shown that in 1 - 5 hours after landing the functional abilities of the cosmonauts are considerably reduced. All the test movements at this time are considerably slower than preflight and the more complicated the task is, the greater significant reduction in orthostatic tolerance: during the first test that occurs 1 - 5 hours after landing. two of four cosmonauts declined to continue the task after the orthostatic test

  3. Application Research on Testing Efficiency of Main Drainage Pump in Coal Mine Using Thermodynamic Theories

    OpenAIRE

    Shang, Deyong

    2017-01-01

    The efficiency of a drainage pump should be tested at regular intervals to master the status of the drainage pump in real time and thus achieve the goal of saving energy. The ultrasonic flowmeter method is traditionally used to measure the flow of the pump. But there are some defects in this kind of method of underground coal mine. This paper first introduces the principle of testing the main drainage pump efficiency in coal mine using thermodynamic theories, then analyzes the energy transfor...

  4. Very long-term sequelae of craniopharyngioma.

    Science.gov (United States)

    Wijnen, Mark; van den Heuvel-Eibrink, Marry M; Janssen, Joseph A M J L; Catsman-Berrevoets, Coriene E; Michiels, Erna M C; van Veelen-Vincent, Marie-Lise C; Dallenga, Alof H G; van den Berge, J Herbert; van Rij, Carolien M; van der Lely, Aart-Jan; Neggers, Sebastian J C M M

    2017-06-01

    Studies investigating long-term health conditions in patients with craniopharyngioma are limited by short follow-up durations and generally do not compare long-term health effects according to initial craniopharyngioma treatment approach. In addition, studies comparing long-term health conditions between patients with childhood- and adult-onset craniopharyngioma report conflicting results. The objective of this study was to analyse a full spectrum of long-term health effects in patients with craniopharyngioma according to initial treatment approach and age group at craniopharyngioma presentation. Cross-sectional study based on retrospective data. We studied a single-centre cohort of 128 patients with craniopharyngioma treated from 1980 onwards (63 patients with childhood-onset disease). Median follow-up since craniopharyngioma presentation was 13 years (interquartile range: 5-23 years). Initial craniopharyngioma treatment approaches included gross total resection ( n  = 25), subtotal resection without radiotherapy ( n  = 44), subtotal resection with radiotherapy ( n  = 25), cyst aspiration without radiotherapy ( n  = 8), and 90 Yttrium brachytherapy ( n  = 21). Pituitary hormone deficiencies (98%), visual disturbances (75%) and obesity (56%) were the most common long-term health conditions observed. Different initial craniopharyngioma treatment approaches resulted in similar long-term health effects. Patients with childhood-onset craniopharyngioma experienced significantly more growth hormone deficiency, diabetes insipidus, panhypopituitarism, morbid obesity, epilepsy and psychiatric conditions compared with patients with adult-onset disease. Recurrence-/progression-free survival was significantly lower after initial craniopharyngioma treatment with cyst aspiration compared with other therapeutic approaches. Survival was similar between patients with childhood- and adult-onset craniopharyngioma. Long-term health conditions were comparable after

  5. Update Knowledge Base for Long-term Core Cooling Reliability

    International Nuclear Information System (INIS)

    Agrell, Maria; Sandervag, Oddbjoern; Amri, Abdallah; ); Bang, Young S.; Blomart, Philippe; Broecker, Annette; Pointner, Winfried; Ganzmann, Ingo; Lenogue, Bruno; Guzonas, David; Herer, Christophe; Mattei, Jean-Marie; Tricottet, Matthieu; Masaoka, Hideaki; Soltesz, Vojtech; Tarkiainen, Seppo; Ui, Atsushi; Villalba, Cristina; Zigler, Gilbert

    2013-11-01

    This revision of the Knowledge Base for Emergency Core Cooling System Recirculation Reliability (NEA/CSNI/R (95)11) describes the current status (late 2012) of the knowledge base on emergency core cooling system (ECCS) and containment spray system (CSS) suction strainer performance and long-term cooling in operating power reactors. New reactors, such as the AP1000, EPR and APR1400 that are under construction in some Organization for Economic Co-operation and Development (OECD) member countries, are not addressed in detail in this revision. The containment sump (also known as the emergency or recirculation sump in pressurized water reactors (PWRs) and pressurized heavy water reactors (PHWRs) or the suppression pools or wet wells in boiling water reactors (BWRs)) and associated ECCS strainers are parts of the ECCS in both reactor types. All nuclear power plants (NPPs) are required to have an ECCS that is capable of mitigating a design basis accident (DBA). The containment sump collects reactor coolant, ECCS injection water, and containment spray solutions, if applicable, after a loss-of-coolant accident (LOCA). The sump serves as the water source to support long-term recirculation for residual heat removal, emergency core cooling, and containment atmosphere clean-up. This water source, the related pump suction inlets, and the piping between the source and inlets are important safety-related components. In addition, if fibrous material is deposited at the fuel element spacers, core cooling can be endangered. The performance of ECCS/CSS strainers was recognized many years ago as an important regulatory and safety issue. One of the primary concerns is the potential for debris generated by a jet of high-pressure coolant during a LOCA to clog the strainer and obstruct core cooling. The issue was considered resolved for all reactor types in the mid-1990s and the OECD/NEA/CSNI published report NEA/CSNI/R(95)11 in 1996 to document the state of knowledge of ECCS performance

  6. On-line PWR RHR pump performance testing following motor and impeller replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiMarzo, J.T.

    1996-12-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump`s `B` impeller. The spare was installed into the `B` train. The motor had never been run in the system before. A pump performance test was developed to verify it`s operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the `B` Train showed performance well in excess of the minimum required. The motor that was originally in the `B` train was similarly overhauled and equipped with `A` pump`s original impeller, re-installed in the `A` train, and tested. Analysis of the `A` train results indicate that the RHR pump`s performance was also well in excess of the vendors requirements.

  7. Long-term properties of bituminized waste products

    International Nuclear Information System (INIS)

    Snellman, M.; Valkiainen, M.

    1985-10-01

    This study is a survey of the factors of importance for the long term behaviour of bituminized ion exchange resins. Phenomena occurring in bituminized waste products affected by the treatment, storage and disposal are identified. Test methods have been developed for characterizing product properties, which are important for the long-term behaviour. The long-term properties of bituminized ion-exchange resins are studied in a repository environment with access of water equilibrated with concrete. In these circumstances the most important properties are related to the interactions of bituminized waste with the surrounding barriers. The most important phenomena are water uptake due to rehydration of the resins and subsequent swelling of the product

  8. Long-term properties of bituminized waste products

    International Nuclear Information System (INIS)

    Snellman, M.; Valkiainen, M.

    1985-10-01

    This study is a survey of the factors of importance for long term behaviour of bituminized ion exchange resins. Phenomena occurring in bituminized waste products affected by the treatment, storage and disposal are identified. Test methods have been developed for characterizing product properties, which are important for the long-term behaviour. The long-term properties of bituminized ion-exchange resins are studied in a repository environment with access of water equilibrated with concrete. In these circumstances the most important properties are ralated to the interactions of bituminized waste with the surrounding barriers. The most important phenomena are water uptake due to rehydration of the resins and subsequent swelling of the product. (author)

  9. Long-term stability scintillation tiles for LHCb detector

    International Nuclear Information System (INIS)

    Grinyov, B.V.; Khlapova, N.P.; Senchyshyn, V.G.; Lebedev, V.N.; Adadurov, A.F.; Melnychuk, S.V.

    2004-01-01

    Accelerated thermal aging tests of materials - UPS-923A, UPS-96G, UPS-96GM and their analogues, SCSN-81 (Kuraray) and BC-408 (Bicron) - were made. A forecast of tile lifetime was made for normal conditions of usage (20% reduction of light output and 50% reduction of the bulk attenuation length (BAL) and technical attenuation length (TAL). Scintillator UPS-96GM has the most long-term stability of parameters--more than 11 yr. BC-408 samples have the minimum lifetime ∼7 yr. The long-term stability, calculated by light yield reduction, of UPS-96G, UPS-923A and SCSN-81 is 10, 9 and 8 yr, respectively

  10. Long-term stability scintillation tiles for LHCb detector

    CERN Document Server

    Grinyov, B V; Khlapova, N P; Lebedev, V N; Melnychuk, S V; Senchyshyn, V G

    2004-01-01

    Accelerated thermal aging tests of materials-UPS-923A, UPS-96G, UPS-96GM and their analogues, SCSN-81 (Kuraray) and BC-408 (Bicron)- were made. A forecast of tile lifetime was made for normal conditions of usage (20% reduction of light output and 50% reduction of the bulk attenuation length (BAL) and technical attenuation length (TAL). Scintillator UPS-96GM has the most long-term stability of parameters- more than 11 yr. BC-408 samples have the minimum lifetime ~7 yr. The long-term stability, calculated by light yield reduction, of UPS-96G, UPS-923A and SCSN-81 is 10, 9 and 8 yr, respectively.

  11. A portable chemotaxis platform for short and long term analysis.

    Directory of Open Access Journals (Sweden)

    Chenjie Xu

    Full Text Available Flow-based microfluidic systems have been widely utilized for cell migration studies given their ability to generate versatile and precisely defined chemical gradients and to permit direct visualization of migrating cells. Nonetheless, the general need for bulky peripherals such as mechanical pumps and tubing and the complicated setup procedures significantly limit the widespread use of these microfluidic systems for cell migration studies. Here we present a simple method to power microfluidic devices for chemotaxis assays using the commercially available ALZET® osmotic pumps. Specifically, we developed a standalone chemotaxis platform that has the same footprint as a multiwell plate and can generate well-defined, stable chemical gradients continuously for up to 7 days. Using this platform, we validated the short-term (24 hours and long-term (72 hours concentration dependent PDGF-BB chemotaxis response of human bone marrow derived mesenchymal stem cells.

  12. The Phillips Laboratory capillary pumped loop test facility

    Science.gov (United States)

    Gluck, Donald F.; Kaylor, Marc C.

    1996-03-01

    An ammonia capillary pumped loop (CPL) test facility has been designed, fabricated, subject to acceptance tests, and assembled at Phillips Laboratory. Its intent is to support a wide range of Air Force programs, bringing CPL technology to flight readiness for operational systems. The facility provides a high degree of modularity and flexibility with several heating and cooling options, and capability for elevation (+/- 15 in.), tilt (+/-60°) and transport length variation. It has a 182 by 44 by 84 inch envelope, an expected heat load capability of 2500 W, and a temperature range of 0 to 50 °C. The evaporator section has two plates with four capillary pumps (CPs) each, with a starter pump on one plate. The CPs are 5/8 in., with TAG aluminum 6063-T6 casing and UHMW polyethylene wicks. The active lengths are 15 and 30 inch with both 10 and 15 micron wicks. The individual CPs have thermal and hydraulic isolation capability, and are removable. The transport section consists of stainless steel lines in a serpentine configuration, a 216 in3 free volume reservoir, and a mechanical pump. The vapor transport line contains a capillary device (which can be bypassed) for vapor blockage during startup. The condenser consists of two separately valved, parallel cold plates each with a downstream noncondensible gas trap. Cooling of up to 1500 W at -50 °C is provided by an FTS Systems chiller using Flourinert FC-72. An enclosure/exhaust system is provided for safety and emergency venting of ammonia. An ammonia charge station performs or supports the functions of proof pressure, flushing with ammonia, purging with gaseous nitrogen, evacuation of all or part of the CPL to 20 microns, and charging. Instrumentation consists of over 116 thermocouples, five of which are internal; one absolute and six differential pressure transducers; eleven watt transducers, and a reservoir load cell. The data acquisition system consists of a temperature scanner, Bernoulli drive, and two Macintosh

  13. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  14. Long-term prisoner in prison isolation

    Directory of Open Access Journals (Sweden)

    Karolina Grudzińska

    2013-06-01

    Full Text Available Long-term prisoner belongs to a particular category of people who are imprisoned in prisons. On the one hand in this group are often heavily demoralized people who committed the most serious crimes, on the other hand it is a group of prisoners, who should be well thought out and programmed the impact of rehabilitation. The situation of man trapped for years poses in a complicated situation not only the prisoners, but also the entire prison staff. They have to take care of the fact that the prison isolation did not cause the state in which convicts form itself in learned helplessness and lack of skills for self-planning and decision-making. In addition, planning the rehabilitation impact of long-term prisoners should not be forgotten that these prisoners in the short or the long term will return to the libertarian environment therefore, should prevent any negative effects of long-term imprisonment. This article presents the main issues related to the execution of imprisonment against long-term prisoners. It is an attempt to systematize the knowledge of this category of people living in prison isolation.

  15. Unconfined aquifer response to infiltration basins and shallow pump tests

    Science.gov (United States)

    Ostendorf, David W.; DeGroot, Don J.; Hinlein, Erich S.

    2007-05-01

    SummaryWe measure and model the unsteady, axisymmetric response of an unconfined aquifer to delayed, arbitrary recharge. Water table drainage follows the initial elastic aquifer response, as modeled for uniform, instantaneous recharge by Zlotnik and Ledder [Zlotnik, V., Ledder, G., 1992. Groundwater flow in a compressible unconfined aquifer with uniform circular recharge. Water Resources Research 28(6), 1619-1630] and delayed drainage by Moench [Moench, A.F., 1995. Combining the Neuman and Boulton models for flow to a well in an unconfined aquifer. Ground Water 33(3), 378-384]. We extend their analyses with a convolution integral that models the delayed response of an aquifer to infiltration from a circular infiltration basin. The basin routes the hydrograph to the water table with a decay constant dependent on a Brooks and Corey [Brooks, R.H., Corey, A.T., 1966. Properties of porous media affecting fluid flow. Journal of the Irrigation and Drainage Division ASCE 92(2), 61-88] unsaturated permeability exponent. The resulting closed form model approaches Neuman's [Neuman, S.P., 1972. Theory of flow in unconfined aquifers considering delayed response of the water table. Water Resources Research 8(4), 1031-1045] partially penetrating pump test equation for a small source radius, instantaneous, uniform drainage and a shallow screen section. Irrigation pump data at a well characterized part of the Plymouth-Carver Aquifer in southeastern Massachusetts calibrate the small source model, while infiltration data from the closed drainage system of State Route 25 calibrate the infiltration basin model. The calibrated permeability, elasticity, specific yield, and permeability exponent are plausible and consistent for the pump and infiltration data sets.

  16. Long-term follow-up study and long-term care of childhood cancer survivors

    Directory of Open Access Journals (Sweden)

    Hyeon Jin Park

    2010-04-01

    Full Text Available The number of long-term survivors is increasing in the western countries due to remarkable improvements in the treatment of childhood cancer. The long-term complications of childhood cancer survivors in these countries were brought to light by the childhood cancer survivor studies. In Korea, the 5-year survival rate of childhood cancer patients is approaching 70%; therefore, it is extremely important to undertake similar long-term follow-up studies and comprehensive long-term care for our population. On the basis of the experiences of childhood cancer survivorship care of the western countries and the current Korean status of childhood cancer survivors, long-term follow-up study and long-term care systems need to be established in Korea in the near future. This system might contribute to the improvement of the quality of life of childhood cancer survivors through effective intervention strategies.

  17. Long-Term Outcomes of Early Reading Intervention

    Science.gov (United States)

    Hurry, Jane; Sylva, Kathy

    2007-01-01

    This study explores the long-term effectiveness of two differing models of early intervention for children with reading difficulties: Reading Recovery and a specific phonological training. Approximately 400 children were pre-tested, 95 were assigned to Reading Recovery, 97 to Phonological Training and the remainder acted as controls. In the short…

  18. Long-Term Forest Hydrologic Monitoring in Coastal Carolinas

    Science.gov (United States)

    Devendra M. Amatya; Ge Sun; Carl C. Trettin; R. Wayne Skaggs

    2003-01-01

    Long-term hydrologic data are essential for understanding the hydrologic processes, as base line data for assessment of impacts and conservation of regional ecosystems, and for developing and testing eco-hydrological models. This study presents 6-year (1996-2001) of rainfall, water table and outflow data from a USDA Forest Service coastal experimental watershed on a...

  19. Long term agro-ecosystem research: The Southern Plains partnership

    Science.gov (United States)

    The USDA Agricultural Research Service (ARS) is coordinating ten well-established research sites as a Long Term Agro-ecosystem Research (LTAR) Network. The goal of the LTAR is to sustain a land-based infrastructure for research, environmental management testing, and education, that enables understan...

  20. Effects of Acute Exercise on Long-Term Memory

    Science.gov (United States)

    Labban, Jeffrey D.; Etnier, Jennifer L.

    2011-01-01

    In this study, we tested the effect of acute exercise on long-term memory, specifically the timing of exercise relative to the memory challenge. We assessed memory via paragraph recall, in which participants listened to two paragraphs (exposure) and recounted them following a 35-min delay. Participants (n = 48) were randomly assigned to one of…

  1. Long-Term Sensitization Training Primes "Aplysia" for Further Learning

    Science.gov (United States)

    Cleary, Leonard J.; Byrne, John H.; Antzoulatos, Evangelos G.; Wainwright, Marcy L.

    2006-01-01

    Repetitive, unilateral stimulation of "Aplysia" induces long-term sensitization (LTS) of ipsilaterally elicited siphon-withdrawal responses. Whereas some morphological effects of training appear only on ipsilateral sensory neurons, others appear bilaterally. We tested the possibility that contralateral morphological modifications may have…

  2. Long-term outcomes of young people who attempted suicide

    NARCIS (Netherlands)

    Grisham, Jessica R; Williams, Alishia D

    2014-01-01

    IMPORTANCE Suicidal behavior has increased since the onset of the global recession, a trend that may have long-term health and social implications. OBJECTIVE To test whether suicide attempts among young people signal increased risk for later poor health and social functioning above and beyond a

  3. Long-Term Prognosis of Plantar Fasciitis

    DEFF Research Database (Denmark)

    Hansen, Liselotte; Krogh, Thøger Persson; Ellingsen, Torkell

    2018-01-01

    , exercise-induced symptoms, bilateral heel pain, fascia thickness, and presence of a heel spur) could predict long-term outcomes, (3) to assess the long-term ultrasound (US) development in the fascia, and (4) to assess whether US-guided corticosteroid injections induce atrophy of the heel fat pad. Study....... The risk was significantly greater for women (P heel...... regardless of symptoms and had no impact on prognosis, and neither did the presence of a heel spur. Only 24% of asymptomatic patients had a normal fascia on US at long-term follow-up. A US-guided corticosteroid injection did not cause atrophy of the heel fat pad. Our observational study did not allow us...

  4. Long term planning for wind energy development

    International Nuclear Information System (INIS)

    Trinick, M.

    1995-01-01

    In a planning system intended to be governed primarily by policies in statutory plans a reasonable horizon for long term planning is 10 years or longer. Because of statutory requirements, developers have no option but to pay due regard to, and take a full part in, long term planning. The paper examines the type of policies which have emerged in the last few years to cater for wind energy development. It canvasses the merits of different types of policies. Finally, it discusses the policy framework which may emerge to cater for development outside NFFO. (Author)

  5. Long-term characteristics of nuclear emulsion

    International Nuclear Information System (INIS)

    Naganawa, N; Kuwabara, K

    2010-01-01

    Long-term characteristics of the nuclear emulsion so called 'OPERA film' used in the neutrino oscillation experiment, OPERA, has been studied for 8 years since its production or refreshing after it. In the results, it turned out to be excellent in sensitivity, amount of random noise, and refreshing characteristics. The retention capacity of latent image of tracks was also studied. The result will open the way to the recycling of 7,000,000 emulsion films which will remain not developed after 5 years of OPERA's run, and other long-term experiments with emulsion.

  6. Long-term characteristics of nuclear emulsion

    Science.gov (United States)

    Naganawa, N.; Kuwabara, K.

    2010-02-01

    Long-term characteristics of the nuclear emulsion so called ``OPERA film'' used in the neutrino oscillation experiment, OPERA, has been studied for 8 years since its production or refreshing after it. In the results, it turned out to be excellent in sensitivity, amount of random noise, and refreshing characteristics. The retention capacity of latent image of tracks was also studied. The result will open the way to the recycling of 7,000,000 emulsion films which will remain not developed after 5 years of OPERA's run, and other long-term experiments with emulsion.

  7. Long-term home care scheduling

    DEFF Research Database (Denmark)

    Gamst, Mette; Jensen, Thomas Sejr

    In several countries, home care is provided for certain citizens living at home. The long-term home care scheduling problem is to generate work plans spanning several days such that a high quality of service is maintained and the overall cost is kept as low as possible. A solution to the problem...... provides detailed information on visits and visit times for each employee on each of the covered days. We propose a branch-and-price algorithm for the long-term home care scheduling problem. The pricing problem generates one-day plans for an employee, and the master problem merges the plans with respect...

  8. Long term storage techniques for 85Kr

    International Nuclear Information System (INIS)

    Foster, B.A.; Pence, D.T.; Staples, B.A.

    1975-01-01

    As new nuclear fuel reprocessing plants go on stream, the collection of fission product 85 Kr will be required to avoid potential local release problems and long-term atmospheric buildup. Storage of the collected 85 Kr for a period of at least 100 years will be necessary to allow approximately 99.9 percent decay before it is released. A program designed to develop and evaluate proposed methods for long-term storage of 85 Kr is discussed, and the results of a preliminary evaluation of three methods, high pressure steel cylinders, zeolite encapsulation, and clathrate inclusion are presented. (U.S.)

  9. The cryogenic pumping section of KATRIN and the test experiment TRAP

    CERN Document Server

    Eichelhardt, F

    2011-01-01

    The Karlsruhe Tritium Neutrino experiment (KATRIN) employs a Cryogenic Pumping Section (CPS) at ~ 4.5 K to suppress the tritium penetration into the spectrometers. A test experiment (TRAP - Tritium Argon frost Pump) has been set up to investigate the tritium pumping performance of the CPS.

  10. Dissociation of Short- and Long-Term Face Memory: Evidence from Long-Term Recency Effects in Temporal Lobe Epilepsy

    Science.gov (United States)

    Bengner, T.; Malina, T.

    2007-01-01

    We tested whether memory deficits in temporal lobe epilepsy (TLE) are better described by a single- or dual-store memory model. To this aim, we analyzed the influence of TLE and proactive interference (PI) on immediate and 24-h long-term recency effects during face recognition in 16 healthy participants and 18 right and 21 left non-surgical TLE…

  11. Nutritional deficit and Long Term Potentiation alterations

    Directory of Open Access Journals (Sweden)

    M. Petrosino

    2009-01-01

    Full Text Available In the present work we examined the ability of prenatally malnourished offspring to produce and maintain long-term potentiation (LTP of the perforant path/dentate granule cell synapse in freely moving rats at 15,30, and 90 days of age. Population spike amplitude (PSA was calculated from dentate field potential recordings prior to and at 15, 30, 60 min. and 3, 5, 18 and 24 h following tetanization of the perforant pathway. All animals of both malnourished and well-nourished diet groups at 15 days of age showed potentiation of PSA measures but the measures obtained from 15-day-old prenatally malnourished animals were significantly less than that of age-matched, well-nourished controls. At 30 days of age, remarkable effect of tetanization was likely observed from PSA measures for this age group followed much the same pattern. At 90 days of age, PSA measures obtained from malnourished animals decreased from pretetanization levels immediately following tetanization. At this age, however, at three hours time recordings, this measure growing up to a level which did not differ significantly from that of the control group. These results indicate that the width of tetanization induced enhancement of dentate granule cell response in preweanling rats (15-day-old animals is signifacantly affected fromgestational protein malnutrition and this trend is kept in animals tested at 30 and 90 days of age. The fact, however, that considerable limitation in LTP generation was gained from prenatally malnourished animals at 90 days of age, implying that dietary rehabilitation starting at birth is an intervention strategy not capable to imbrove the effects of the gestational stress.

  12. Experiences of long-term tranquillizer use

    DEFF Research Database (Denmark)

    Skinhoj, K T; Larsson, S; Helweg-Joergensen, S

    2001-01-01

    , the psychodynamic perspective is integrated within a multi-dimensional model that considers biological, cognitive, identity, gender and social learning factors. The analysis reveals the possibility of achieving a detailed understanding of the dynamic processes involved in the development of long-term tranquillizer...

  13. Long-Term Orientation in Trade

    NARCIS (Netherlands)

    Hofstede, G.J.; Jonker, C.M.; Verwaart, D.

    2008-01-01

    Trust does not work in the same way across cultures. This paper presents an agent model of behavior in trade across Hofstedes cultural dimension of long-term vs. short-term orientation. The situation is based on a gaming simulation, the Trust and Tracing game. The paper investigates the

  14. Long term consequences of early childhood malnutrition

    NARCIS (Netherlands)

    Kinsey, B.H.; Hoddinott, J; Alderman, H.

    2006-01-01

    This paper examines the impact of pre-school malnutrition on subsequent human capital formation in rural Zimbabwe using a maternal fixed effects - instrumental variables (MFE-IV) estimator with a long term panel data set. Representations of civil war and drought shocks are used to identify

  15. Financial Incentives in Long-Term Care

    NARCIS (Netherlands)

    P.L.H. Bakx (Pieter)

    2015-01-01

    markdownabstract__Abstract__ Long-term care (ltc) aims to help individuals to cope with their impairments. In my thesis, I describe ltc financing alternatives and their consequences for the allocation of ltc. This thesis consists of two parts. In the first part, I investigate how alternative ways

  16. Long-term outcomes of patellofemoral arthroplasty.

    NARCIS (Netherlands)

    Jonbergen, J.P.W. van; Werkman, D.M.; Barnaart, L.F.; Kampen, A. van

    2010-01-01

    The purpose of this study was to correlate the long-term survival of patellofemoral arthroplasty with primary diagnosis, age, sex, and body mass index. One hundred eighty-five consecutive Richards type II patellofemoral arthroplasties were performed in 161 patients with isolated patellofemoral

  17. Long-Term Memory and Learning

    Science.gov (United States)

    Crossland, John

    2011-01-01

    The English National Curriculum Programmes of Study emphasise the importance of knowledge, understanding and skills, and teachers are well versed in structuring learning in those terms. Research outcomes into how long-term memory is stored and retrieved provide support for structuring learning in this way. Four further messages are added to the…

  18. The 2013 Long-Term Budget Outlook

    Science.gov (United States)

    2013-09-01

    number of years, leading to substantial additional federal spending. For example, the nation could experience a massive earthquake, a nuclear meltdown...budget surpluses remaining after paying down publicly held debt available for redemption . a. For comparison with the current long-term projections, CBO

  19. Long-term effects of ionizing radiation

    International Nuclear Information System (INIS)

    Kaul, Alexander; Burkart, Werner; Grosche, Bernd; Jung, Thomas; Martignoni, Klaus; Stephan, Guenther

    1997-01-01

    This paper approaches the long-term effects of ionizing radiation considering the common thought that killing of cells is the basis for deterministic effects and that the subtle changes in genetic information are important in the development of radiation-induced cancer, or genetic effects if these changes are induced in germ cells

  20. Pituitary diseases : long-term psychological consequences

    NARCIS (Netherlands)

    Tiemensma, Jitske

    2012-01-01

    Nowadays, pituitary adenomas can be appropriately treated, but patients continue to report impaired quality of life (QoL) despite long-term remission or cure. In patients with Cushing’s disease, Cushing’s syndrome or acromegaly, doctors should be aware of subtle cognitive impairments and the

  1. The long term stability of lidar calibrations

    DEFF Research Database (Denmark)

    Courtney, Michael; Gayle Nygaard, Nicolai

    Wind lidars are now used extensively for wind resource measurements. One of the requirements for the data to be accepted in support of project financing (so-called ‘banka-bility’) is to demonstrate the long-term stability of lidar cali-brations. Calibration results for six Leosphere WindCube li...

  2. Rebalancing for Long-Term Investors

    NARCIS (Netherlands)

    Driessen, Joost; Kuiper, Ivo

    2017-01-01

    In this study we show that the rebalance frequency of a multi-asset portfolio has only limited impact on the utility of a long-term passive investor. Although continuous rebalancing is optimal, the loss of a suboptimal strategy corresponds to up to only 30 basis points of the initial wealth of the

  3. SNS Cryogenic Test Facility Kinney Vacuum Pump Commissioning and Operation at 2 K

    Science.gov (United States)

    DeGraff, B.; Howell, M.; Kim, S.; Neustadt, T.

    2017-12-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinney pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.

  4. SNS Cryogenic Test Facility Kinney Vacuum Pump Commissioning and Operation at 2 K

    Energy Technology Data Exchange (ETDEWEB)

    Degraff, Brian D. [ORNL; Howell, Matthew P. [ORNL; Kim, Sang-Ho [ORNL; Neustadt, Thomas S. [ORNL

    2017-07-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinney pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.

  5. Randomized Phase III Trial to Test Accelerated Versus Standard Fractionation in Combination With Concurrent Cisplatin for Head and Neck Carcinomas in the Radiation Therapy Oncology Group 0129 Trial: Long-Term Report of Efficacy and Toxicity

    Science.gov (United States)

    Nguyen-Tan, Phuc Felix; Zhang, Qiang; Ang, K. Kian; Weber, Randal S.; Rosenthal, David I.; Soulieres, Denis; Kim, Harold; Silverman, Craig; Raben, Adam; Galloway, Thomas J.; Fortin, André; Gore, Elizabeth; Westra, William H.; Chung, Christine H.; Jordan, Richard C.; Gillison, Maura L.; List, Marcie; Le, Quynh-Thu

    2014-01-01

    Purpose We tested the efficacy and toxicity of cisplatin plus accelerated fractionation with a concomitant boost (AFX-C) versus standard fractionation (SFX) in locally advanced head and neck carcinoma (LA-HNC). Patients and Methods Patients had stage III to IV carcinoma of the oral cavity, oropharynx, hypopharynx, or larynx. Radiation therapy schedules were 70 Gy in 35 fractions over 7 weeks (SFX) or 72 Gy in 42 fractions over 6 weeks (AFX-C). Cisplatin doses were 100 mg/m2 once every 3 weeks for two (AFX-C) or three (SFX) cycles. Toxicities were scored by using National Cancer Institute Common Toxicity Criteria 2.0 and the Radiation Therapy Oncology Group/European Organisation for Research and Treatment of Cancer criteria. Overall survival (OS) and progression-free survival (PFS) rates were estimated by using the Kaplan-Meier method and were compared by using the one-sided log-rank test. Locoregional failure (LRF) and distant metastasis (DM) rates were estimated by using the cumulative incidence method and Gray's test. Results In all, 721 of 743 patients were analyzable (361, SFX; 360, AFX-C). At a median follow-up of 7.9 years (range, 0.3 to 10.1 years) for 355 surviving patients, no differences were observed in OS (hazard ratio [HR], 0.96; 95% CI, 0.79 to 1.18; P = .37; 8-year survival, 48% v 48%), PFS (HR, 1.02; 95% CI, 0.84 to 1.24; P = .52; 8-year estimate, 42% v 41%), LRF (HR, 1.08; 95% CI, 0.84 to 1.38; P = .78; 8-year estimate, 37% v 39%), or DM (HR, 0.83; 95% CI, 0.56 to 1.24; P = .16; 8-year estimate, 15% v 13%). For oropharyngeal cancer, p16-positive patients had better OS than p16-negative patients (HR, 0.30; 95% CI, 0.21 to 0.42; P < .001; 8-year survival, 70.9% v 30.2%). There were no statistically significant differences in the grade 3 to 5 acute or late toxicities between the two arms and p-16 status. Conclusion When combined with cisplatin, AFX-C neither improved outcome nor increased late toxicity in patients with LA-HNC. Long-term high survival

  6. Long Term Remote Monitoring of TCE Contaminated Groundwater at Savannah River Site

    International Nuclear Information System (INIS)

    Duran, C.; Gudavalli, R.; Lagos, L.; Tansel, B.; Varona, J.; Allen, M.

    2004-01-01

    The purpose of this study was to develop a mobile self powered remote monitoring system enhanced for field deployment at Savannah River Site (SRS). The system used a localized power source with solar recharging and has wireless data collection, analysis, transmission, and data management capabilities. The prototype was equipped with a Hydrolab's DataSonde 4a multi-sensor array package managed by a Supervisory Control and Data Acquisition (SCADA) system, with an adequate pumping capacity of water samples for sampling and analysis of Trichloroethylene (TCE) in contaminated groundwater wells at SRS. This paper focuses on a study and technology development efforts conducted at the Hemispheric Center for Environmental Technology (HCET) at Florida International University (FIU) to automate the sampling of contaminated wells with a multi-sensor array package developed using COTS (Commercial Off The shelf) parts. Bladder pumps will pump water from different wells to the sensors array, water quality TCE indicator parameters are measured (i.e. pH, redox, ORP, DO, NO3 -, Cl-). In order to increase user access and data management, the system was designed to be accessible over the Internet. Remote users can take sample readings and collect data remotely over a web. Results obtained at Florida International University in-house testing and at a field deployment at the Savannah River Site indicate that this long term monitoring technique can be a feasible solution for the sampling of TCE indicator parameters at remote contaminated sites

  7. Long Term Monitoring of Microbial Induced Soil Strengthening Processes

    Science.gov (United States)

    Saneiyan, S.; Ntarlagiannis, D.; Werkema, D. D., Jr.; Colwell, F. S.; Ohan, J.

    2016-12-01

    Soil strengthening/stabilization processes are used to address some of soil quality issues. Microbial induced calcite precipitation (MICP) is a promising soil stabilization process that could offer long term solution by overcoming problems of commonly used methods (e.g. injecting cement slurry). MICP can be applied in larger spatial scales, allowing the enhanced soils to be maintained in an economic sustainable and environmental friendly way. Methods are sought for the long term monitoring of MICP enhanced soils. The spectral induced polarization (SIP) method is one promising method due to sensitivity on such processes and the ability for long term, even autonomous, operation as well as cost effectiveness. Previous laboratory tests showed the sensitivity of the SIP method on soil strengthening as a result of abiotic calcite precipitation. We extended this work to biotic calcite precipitation through MICP. Early results suggest that the MICP formed calcite is denser and could provide improved strengthening capabilities. Our results are supported by geophysical (SIP and shear-wave velocity), geo-chemical and microbiological monitoring. Destructive analysis and visualization (scanning electron imaging - SEM) is expected to provide conclusive evidence on the MICP long term effectiveness.

  8. Endurance Pump Test with MIL-PRF-83282 Hydraulic Fluid, Purified with Malabar Purifier

    National Research Council Canada - National Science Library

    Sharma, Shashi

    2004-01-01

    .... Endurance aircraft hydraulic pump tests under carefully controlled conditions were previously conducted using hydraulic fluid purified with a rotating-disk and vacuum type purifier, the portable...

  9. Properties of cast Ti-stabilised stainless steel after long-term ageing

    International Nuclear Information System (INIS)

    Ehrnsten, U.; Karjalainen-Roikonen, P.; Nenonen, P.; Ahlstrand, R.; Hietanen, O.; Timofeev, B.T.; Bloomin, A.A.

    2000-01-01

    Mechanical properties and microstructure are studied and compared for two kinds of specimens of cast Ti-stabilized stainless steel 08Kh18N10T used for manufacturing of valves and pumps in nuclear power plants. One set of specimens represents the main gate valve material after 106000 h (∼ 12 years) operation at 270 deg C. The comparison is made with reference specimens in as-fabricated state. The results of impact tests, hardness measurements and microscopic examination show that 12 year operation gives rise to the shift of ductile-brittle transition temperature to higher values (from - 68 deg C - 103 deg C). The microstructure of both materials is similar. The microhardness of δ-ferrite in the steel after long-term operation is slightly higher [ru

  10. On-line PWR RHR pump performance testing following motor and impeller replacement

    International Nuclear Information System (INIS)

    DiMarzo, J.T.

    1996-01-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump's 'B' impeller. The spare was installed into the 'B' train. The motor had never been run in the system before. A pump performance test was developed to verify it's operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the 'B' Train showed performance well in excess of the minimum required. The motor that was originally in the 'B' train was similarly overhauled and equipped with 'A' pump's original impeller, re-installed in the 'A' train, and tested. Analysis of the 'A' train results indicate that the RHR pump's performance was also well in excess of the vendors requirements

  11. Application Research on Testing Efficiency of Main Drainage Pump in Coal Mine Using Thermodynamic Theories

    Directory of Open Access Journals (Sweden)

    Deyong Shang

    2017-01-01

    Full Text Available The efficiency of a drainage pump should be tested at regular intervals to master the status of the drainage pump in real time and thus achieve the goal of saving energy. The ultrasonic flowmeter method is traditionally used to measure the flow of the pump. But there are some defects in this kind of method of underground coal mine. This paper first introduces the principle of testing the main drainage pump efficiency in coal mine using thermodynamic theories, then analyzes the energy transformation during the process of draining water, and finally derives the calculation formulae of the pump efficiency, which meet the on-site precision of engineering. On the basis of analyzing the theories, the protective sleeve and the base of the temperature sensor are designed to measure the water temperature at inlet and outlet of the pump. The efficiencies of pumps with two specifications are measured, respectively, by using the thermodynamic method and ultrasonic flowmeter method. By contrast, the results show that thermodynamic method can satisfy the precision of the testing requirements accuracy for high-flow and high-lift drainage pump under normal temperatures. Moreover, some measures are summed up to improve the accuracy of testing the pump efficiency, which are of guiding significance for on-site testing of the main drainage pump efficiency in coal mine.

  12. Evaluation of a nonevaporable getter pump for tritium handling in the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Singleton, M.F.; Griffith, C.M.

    1978-01-01

    Lawrence Livermore Laboratory has tested and evaluated a commercially available getter pump for use with tritium in the Tokamak Fusion Test Reactor (TFTR). The pump contains Zr(84%)--Al in cartridge form with a concentric heating unit. It performed well in all tests, except for frequent heater failures

  13. Long-term selenium status in humans

    International Nuclear Information System (INIS)

    Baskett, C.K.; Spate, V.L.; Mason, M.M.; Nichols, T.A.; Williams, A.; Dubman, I.M.; Gudino, A.; Denison, J.; Morris, J.S.

    2001-01-01

    The association of sub-optimal selenium status with increased risk factors for some cancers has been reported in two recent epidemiological studies. In both studies the same threshold in selenium status was observed, below which, cancer incidence increased. To assess the use of nails as a biologic monitor to measure the long-term selenium status, an eight-year longitudinal study was undertaken with a group of 11 adult subjects, 5 women and 6 men. Selenium has been measured by instrumental neutron activation analysis. Differences between fingernails and toenails with be discussed. In addition, the results will be discussed in the context of the long-term stability of the nail monitor to measure selenium status during those periods when selenium determinants are static; and the changes that occur as a result of selenium supplementation. (author)

  14. Influenza in long-term care facilities.

    Science.gov (United States)

    Lansbury, Louise E; Brown, Caroline S; Nguyen-Van-Tam, Jonathan S

    2017-09-01

    Long-term care facility environments and the vulnerability of their residents provide a setting conducive to the rapid spread of influenza virus and other respiratory pathogens. Infections may be introduced by staff, visitors or new or transferred residents, and outbreaks of influenza in such settings can have devastating consequences for individuals, as well as placing extra strain on health services. As the population ages over the coming decades, increased provision of such facilities seems likely. The need for robust infection prevention and control practices will therefore remain of paramount importance if the impact of outbreaks is to be minimised. In this review, we discuss the nature of the problem of influenza in long-term care facilities, and approaches to preventive and control measures, including vaccination of residents and staff, and the use of antiviral drugs for treatment and prophylaxis, based on currently available evidence. © 2017 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  15. Long-Term Ownership by Industrial Foundations

    DEFF Research Database (Denmark)

    Børsting, Christa Winther; Kuhn, Johan Moritz; Poulsen, Thomas

    2016-01-01

    in Denmark. Industrial foundations are independent legal entities without owners or members typically with the dual objective of preserving the company and using excess profits for charity. We use a unique Danish data set to examine the governance of foundation-owned companies. We show that they are long......-term in several respects. Foundations hold on to their shares for longer. Foundation-owned companies replace managers less frequently. They have more conservative capital structures with less leverage. Their companies survive longer. Their business decisions appear to be more long term. This paper supports...... the hypothesis that time horizons are influenced by ownership structures and particularly that industrial foundations promote longtermism. Policymakers which are interested in promoting longtermism should allow and perhaps even encourage the creation of industrial foundations. More generally they should consider...

  16. Analysis of long-term energy scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Lemming, J.; Morthorst, P.E.

    1998-09-01

    When addressing the role of fusion energy in the 21. century, the evaluation of possible future structures in the electricity market and the energy sector as a whole, can be a useful tool. Because fusion energy still needs demonstration, commercialized fusion energy is not likely to be a reality within the next few decades. Therefore long-term scenarios are needed describing the energy markets, which fusion energy eventually will be part of. This report performs an analysis of two of the most detailed existing long-term scenarios describing possible futures of the energy system. The aim is to clarify the frames in which the future development of the global energy demand, as well as the structure of the energy system can be expected to develop towards the year 2100. (au) 19 refs.

  17. Long-term effects of radiation

    International Nuclear Information System (INIS)

    Smith, J.; Smith, T.

    1981-01-01

    It is pointed out that sources of long-term damage from radiation are two-fold. People who have been exposed to doses of radiation from initial early fallout but have recovered from the acute effects may still suffer long-term damage from their exposure. Those who have not been exposed to early fallout may be exposed to delayed fallout, the hazards from which are almost exclusively from ingesting strontium, caesium and carbon isotopes present in food; the damage caused is relatively unimportant compared with that caused by the brief doses from initial radiation and early fallout. A brief discussion is presented of the distribution of delayed long-lived isotope fallout, and an outline is sketched of late biological effects, such as malignant disease, cataracts, retarded development, infertility and genetic effects. (U.K.)

  18. Residential gas-fired sorption heat pumps. Test and technology evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Naeslund, M.

    2008-12-15

    Heat pumps may be the next step in gas-fired residential space heating. Together with solar energy it is an option to combine natural gas and renewable energy. Heat pumps for residential space heating are likely to be based on the absorption or adsorption process, i.e. sorption heat pumps. Manufacturers claim that the efficiency could reach 140-160%. The annual efficiency will be lower but it is clear that gas-fired heat pumps can involve an efficiency and technology step equal to the transition from non-condensing gas boilers with atmospheric burners to condensing boilers. This report contains a review of the current sorption gas-fired heat pumps for residential space heating and also the visible development trends. A prototype heat pump has been laboratory tested. Field test results from Germany and the Netherlands are also used for a technology evaluation. The tested heat pump unit combines a small heat pump and a supplementary condensing gas boiler. Field tests show an average annual efficiency of 120% for this prototype design. The manufacturer abandoned the tested design during the project period and the current development concentrates on a heat pump design only comprising the heat pump, although larger. The heat pump development at three manufacturers in Germany indicates a commercial stage around 2010-2011. A fairly high electricity consumption compared to traditional condensing boilers was observed in the tested heat pump. Based on current prices for natural gas and electricity the cost savings were estimated to 12% and 27% for heat pumps with 120% and 150% annual efficiency respectively. There is currently no widespread performance testing procedure useful for annual efficiency calculations of gas-fired heat pumps. The situation seems to be clearer for electric compression heat pumps regarding proposed testing and calculation procedures. A German environmental label exists and gasfired sorption heat pumps are also slightly treated in the Eco-design work

  19. Long term economic relationships from cointegration maps

    Science.gov (United States)

    Vicente, Renato; Pereira, Carlos de B.; Leite, Vitor B. P.; Caticha, Nestor

    2007-07-01

    We employ the Bayesian framework to define a cointegration measure aimed to represent long term relationships between time series. For visualization of these relationships we introduce a dissimilarity matrix and a map based on the sorting points into neighborhoods (SPIN) technique, which has been previously used to analyze large data sets from DNA arrays. We exemplify the technique in three data sets: US interest rates (USIR), monthly inflation rates and gross domestic product (GDP) growth rates.

  20. Murine model of long term obstructive jaundice

    Science.gov (United States)

    Aoki, Hiroaki; Aoki, Masayo; Yang, Jing; Katsuta, Eriko; Mukhopadhyay, Partha; Ramanathan, Rajesh; Woelfel, Ingrid A.; Wang, Xuan; Spiegel, Sarah; Zhou, Huiping; Takabe, Kazuaki

    2016-01-01

    Background With the recent emergence of conjugated bile acids as signaling molecules in cancer, a murine model of obstructive jaundice by cholestasis with long-term survival is in need. Here, we investigated the characteristics of 3 murine models of obstructive jaundice. Methods C57BL/6J mice were used for total ligation of the common bile duct (tCL), partial common bile duct ligation (pCL), and ligation of left and median hepatic bile duct with gallbladder removal (LMHL) models. Survival was assessed by Kaplan-Meier method. Fibrotic change was determined by Masson-Trichrome staining and Collagen expression. Results 70% (7/10) of tCL mice died by Day 7, whereas majority 67% (10/15) of pCL mice survived with loss of jaundice. 19% (3/16) of LMHL mice died; however, jaundice continued beyond Day 14, with survival of more than a month. Compensatory enlargement of the right lobe was observed in both pCL and LMHL models. The pCL model demonstrated acute inflammation due to obstructive jaundice 3 days after ligation but jaundice rapidly decreased by Day 7. The LHML group developed portal hypertension as well as severe fibrosis by Day 14 in addition to prolonged jaundice. Conclusion The standard tCL model is too unstable with high mortality for long-term studies. pCL may be an appropriate model for acute inflammation with obstructive jaundice but long term survivors are no longer jaundiced. The LHML model was identified to be the most feasible model to study the effect of long-term obstructive jaundice. PMID:27916350

  1. Long-term course of opioid addiction.

    Science.gov (United States)

    Hser, Yih-Ing; Evans, Elizabeth; Grella, Christine; Ling, Walter; Anglin, Douglas

    2015-01-01

    Opioid addiction is associated with excess mortality, morbidities, and other adverse conditions. Guided by a life-course framework, we review the literature on the long-term course of opioid addiction in terms of use trajectories, transitions, and turning points, as well as other factors that facilitate recovery from addiction. Most long-term follow-up studies are based on heroin addicts recruited from treatment settings (mostly methadone maintenance treatment), many of whom are referred by the criminal justice system. Cumulative evidence indicates that opioid addiction is a chronic disorder with frequent relapses. Longer treatment retention is associated with a greater likelihood of abstinence, whereas incarceration is negatively related to subsequent abstinence. Over the long term, the mortality rate of opioid addicts (overdose being the most common cause) is about 6 to 20 times greater than that of the general population; among those who remain alive, the prevalence of stable abstinence from opioid use is low (less than 30% after 10-30 years of observation), and many continue to use alcohol and other drugs after ceasing to use opioids. Histories of sexual or physical abuse and comorbid mental disorders are associated with the persistence of opioid use, whereas family and social support, as well as employment, facilitates recovery. Maintaining opioid abstinence for at least five years substantially increases the likelihood of future stable abstinence. Recent advances in pharmacological treatment options (buprenorphine and naltrexone) include depot formulations offering longer duration of medication; their impact on the long-term course of opioid addiction remains to be assessed.

  2. Long-term economic outlook. Annual review

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    This review provides economic growth forecast tables for Ontario, Canada, the US, Western Europe, and Japan. Economic growth, government policy, the long-term prospects for inflation, interest rates and foreign exchange rates, trends in the Canadian dollar, and energy markets and prices are also reviewed. Data generally cover 1965-2025. Appendices give a summary of historical and forecast data. 18 figs., 16 tabs.

  3. Long-term data storage in diamond

    OpenAIRE

    Dhomkar, Siddharth; Henshaw, Jacob; Jayakumar, Harishankar; Meriles, Carlos A.

    2016-01-01

    The negatively charged nitrogen vacancy (NV?) center in diamond is the focus of widespread attention for applications ranging from quantum information processing to nanoscale metrology. Although most work so far has focused on the NV? optical and spin properties, control of the charge state promises complementary opportunities. One intriguing possibility is the long-term storage of information, a notion we hereby introduce using NV-rich, type 1b diamond. As a proof of principle, we use multic...

  4. French Approach for Long Term Storage Safety

    International Nuclear Information System (INIS)

    Marciano, Jacob; Carreton, Jean-Pierre; Lizot, Marie Therese; Lhomme, Veronique

    2014-01-01

    IRSN presents its statement regarding long-term storage facilities; in France, the regulatory documents do not define the long term duration. The storage facility lifetime can only be appreciated according to the needs and materials stored therein. However, the magnitude of the long-term can be estimated at a few hundred years compared to a few decades for current storage. Usually, in France, construction of storage facilities is driven from the necessity various necessities, linked to the management of radioactive material (eg spent fuel) and to the management of radioactive waste. Because of the variety of 'stored materials and objects' (fission product solutions, plutonium oxide powders, activated solids, drums containing technological waste, spent fuel...), a great number of storage facility design solutions have been developed (surface, subsurface areas, dry or wet conditions...) in the World. After describing the main functions of a storage facility, IRSN displays the safety principles and the associated design principles. The specific design principles applied to particular storage (dry or wet spent fuel storage, depleted uranium or reprocessed uranium storage, plutonium storage, waste containing tritium storage, HLW and ILLW storage...) are also presented. Finally, the concerns due to the long-term duration storage and related safety assessment are developed. After discussing these issues, IRSN displays its statement. The authorization procedures governing the facility lifetime are similar to those of any basic nuclear installation, the continuation of the facility operation remaining subject to periodic safety reviews (in France, every 10 years). The applicant safety cases have to show, that the safety requirements are always met; this requires, at minimum, to take into account at the design stage, comfortable design margins. (author)

  5. Accounting of Long-Term Biological Assets

    OpenAIRE

    Valeriy Mossakovskyy; Vasyl Korytnyy

    2015-01-01

    The article is devoted to generalization of experience in valuation of long-term biological assets of plant-growing and animal-breeding, and preparation of suggestions concerning improvement of accounting in this field. Recommendations concerning accounting of such assets are given based on the study of accounting practice at specific agricultural company during long period of time. Authors believe that fair value is applicable only if price level for agricultural products is fixed by the gov...

  6. Optimal long-term contracting with learning

    OpenAIRE

    He, Zhiguo; Wei, Bin; Yu, Jianfeng; Gao, Feng

    2016-01-01

    We introduce uncertainty into Holmstrom and Milgrom (1987) to study optimal long-term contracting with learning. In a dynamic relationship, the agent's shirking not only reduces current performance but also increases the agent's information rent due to the persistent belief manipulation effect. We characterize the optimal contract using the dynamic programming technique in which information rent is the unique state variable. In the optimal contract, the optimal effort is front-loaded and decr...

  7. Inflation Hedging for Long-Term Investors

    OpenAIRE

    Shaun K. Roache; Alexander P. Attie

    2009-01-01

    Long-term investors face a common problem-how to maintain the purchasing power of their assets over time and achieve a level of real returns consistent with their investment objectives. While inflation-linked bonds and derivatives have been developed to hedge the effects of inflation, their limited supply and liquidity lead many investors to continue to rely on the indirect hedging properties of traditional asset classes. In this paper, we assess these properties over different time horizons,...

  8. Long-Term Care Services for Veterans

    Science.gov (United States)

    2017-02-14

    includes but is not limited to home physical , occupational, or speech therapy ; wound care; and intravenous (IV) care. A VA physician determines that a...restoring/rehabilitating the veteran’s health, such as skilled nursing care, physical therapy , occupational therapy , and IV therapy Same as HBPC... geriatric evaluation,  palliative care,  adult day health care,  homemaker/home health aide care,  respite care, Long-Term Care Services for

  9. Long term adequacy of uranium resources

    International Nuclear Information System (INIS)

    Steyn, J.

    1990-01-01

    This paper examines the adequacy of world economic uranium resources to meet requirements in the very long term, that is until at least 2025 and beyond. It does so by analysing current requirements forecasts, existing and potential production centre supply capability schedules and national resource estimates. It takes into account lead times from resource discovery to production and production rate limitations. The institutional and political issues surrounding the question of adequacy are reviewed. (author)

  10. Microscopic study of rock for estimating long-term behavior

    International Nuclear Information System (INIS)

    Ichikawa, Yasuaki

    2002-03-01

    Micro-structure of rock plays a essential role for their long-term behavior. For elucidating long-term characteristics of granite we here present the followings: 1) Conforcal Laser Scanning Microscope (LSM) observation of joint surfaces of granite and Fourier analysis, 2) characterization of the mechanism of microcrack initiation and propagation observed by stereoscopic microscope under uniaxial/triaxial compression and relaxation tests, 3) observation of microcrack initiation and propagation by LSM under uniaxial compression, and 4) a viscoelastic homogenization theory to predict the long-term behavior of micro/macro-level stress for granite. Rock image processing and analysis become a fundamental procedure to determine rock surface discontinuities. But the complexity of rock surface discontinuities seems beyond the manual image processing method. In Chapter 2 a Conforcal Laser Scanning Microscope that can acquire three-dimensional images is introduced to observe the rock roughness of a discontinuity. Then, scanning three-dimensional images are changed its data form in order to adapt various image analysis programs, and granitic rock roughness of discontinuities are displayed by graphic images. For example, these datas are analyzed by Discrete Fourier Transformation (DFT) program and Inverse Discrete Fourier Transformation (IDFT) program. Microcrack generation and propagation play an essential role to predict the long-term behavior of rock. In Chapter 3 a progressive development of cracking in granite is revealed by using stereoscopic microscope under triaxial compression condition and by using LSM under uniaxial compression condition. With a viscoelastic theory applied in homogenization method, we can calculate macro behavior of medium influenced by its micro structure by analyse the long-term time-dependent behavior of granite under the same condition to the relaxation experiment. (author)

  11. Long-term sealing of openings in salt formations

    International Nuclear Information System (INIS)

    Walter, F.; Stockmann, N.; Yaramanci, U.; Laurens, J.F.

    1993-01-01

    Radioactive wastes can be disposed of in deep salt formations. Rock salt is a suitable geologic medium because of its unique characteristics. Open boreholes, shafts and drifts are created to provide physical access to the repository. Long-term seals must be emplaced in those potential pathways to prevent radioactive release to the biosphere. The sealing materials must be mechanically and, most important, geochemically stable within the host rock. Salt bricks made of compressed salt-powder are understood to be the first choice long-term sealing material. Seals built from salt bricks will be ductile. The permeability of the salt bricks is assumed to be in the order of 2*10 -15 m 2 . Large sealing systems are built by combining the individual bricks with mortar. Raw materials for mortar are fine-grained halite powder and ground saliferous clay. The permeability of the mortar decreases with its salt content to approx. 2*10 -14 m 2 . Moistened saliferous clay may show temporary swelling. Sealing experiments will be carried out in the Asse salt mine. Long-term seals will be built into holes of 1 m diameter. The contact and merging of the brick-wall with the surrounding rock salt will be investigated in long-term tests. Within the in situ sealing program a number of geophysical methods are applied. Acoustic emission measurements are used to study the effects of high pressure gas injection and a geoelectrical observation program is aiming to estimate the permeability in and around the long-term seal. High frequency electromagnetic methods contribute to the knowledge of the petrophysical rock properties. 11 refs., 12 figs

  12. A highly reliable cryogenic mixing pump with no mechanical moving parts

    Science.gov (United States)

    Chen, W.; Niblick, A. L.

    2017-12-01

    This paper presents the design and preliminary test results of a novel cryogenic mixing pump based on magnetocaloric effect. The mixing pump is developed to enable long-term cryogenic propellant storage in space by preventing thermal stratification of cryogens in storage tanks. The mixing pump uses an innovative thermodynamic process to generate fluid jets to promote fluid mixing, eliminating the need for mechanical pumps. Its innovative mechanism uses a solid magnetocaloric material to alternately vaporize and condense the cryogen in the pumping chamber, and thus control the volume of the fluid inside the pumping chamber to produce pumping action. The pump is capable of self-priming and can generate a high-pressure rise. This paper discusses operating mechanism and design consideration of the pump, introduces the configuration of a brassboard cryogenic pump, and presents the preliminary test results of the pump with liquid nitrogen.

  13. Characterization of long term field aging of polymer modified bitumen in porous asphalt

    NARCIS (Netherlands)

    Vliet, D. van; Erkens, S.; Leegwater, G.A.

    2012-01-01

    The effect of long term field aging on different types of polymer modified binders used in two-layer porous asphalt is studied using different test methods. Chemical and rheological tests are performed on samples taken from road sections at different moments in time in search of trends in long term

  14. Long-term high temperature strength of 316FR steel

    International Nuclear Information System (INIS)

    Takahashi, Yukio

    1995-01-01

    As low-carbon medium-nitrogen type 316 stainless steel (316FR) was selected as a primary candidate for main structural material of a next fast reactor plant in Japan, its long-term high-temperature strength gains much interest from many organizations involved in design activities of the plant. Central Research Institute of Electric Power Industry (CRIEPI), as a research organization for electric power industry in Japan, has been conducting a multi-year project under the sponsorship of Ministry of International Trade and Industry (MITI) for studying the long-term high temperature strength of this steel. Data obtained by various strength tests, including short-time tensile, fatigue, creep and creep-fatigue tests for this steel are given in this paper. The results of study on creep-fatigue life prediction methods are also presented. It was found that modified ductility exhaustion method previously proposed by the author has satisfactory accuracy in creep-fatigue life estimation

  15. Sexuality and Physical Intimacy in Long Term Care: Sexuality, long term care, capacity assessment

    OpenAIRE

    Lichtenberg, Peter A.

    2014-01-01

    Sexuality and sexual needs in older adults remains a neglected area of clinical intervention, particularly so in long term care settings. Because older adults in medical rehabilitation and long term care beds present with significant frailties, and often significant neurocognitive disorders it makes it difficult for occupational therapists and other staff to evaluate the capacity of an older adult resident to participate in sexual relationships. The current paper reviews the current literatur...

  16. Narrow Framing and Long-Term Care Insurance

    OpenAIRE

    Daniel Gottlieb; Olivia S. Mitchell

    2015-01-01

    We propose a model of narrow framing in insurance and test it using data from a new module we designed and fielded in the Health and Retirement Study. We show that respondents subject to narrow framing are substantially less likely to buy long-term care insurance than average. This effect is distinct from, and much larger than, the effects of risk aversion or adverse selection, and it offers a new explanation for why people underinsure their later-life care needs.

  17. Long-term outcomes of young people who attempted suicide

    OpenAIRE

    Grisham, Jessica R; Williams, Alishia D

    2014-01-01

    IMPORTANCE Suicidal behavior has increased since the onset of the global recession, a trend that may have long-term health and social implications. OBJECTIVE To test whether suicide attempts among young people signal increased risk for later poor health and social functioning above and beyond a preexisting psychiatric disorder. DESIGN We followed up a cohort of young people and assessed multiple aspects of their health and social functioning as they approached midlife. Outcomes among individu...

  18. Long-term bedrock behavior research for soft rock

    International Nuclear Information System (INIS)

    Inoue, Hiroyuki; Noda, Kenji

    2002-02-01

    When a formation disposal system is thought about, it is important to evaluate long-term dynamics behavior of boundary condition and near field bedrock of an artificial barrier adequately. In this study, three matters were executed for improvement of a dependability of the evaluation as follows. (1) Creep test was executed as purpose by dependability improvement of evaluation technique of creep problem by Okubo model. Okubo model constant was calculated than the unconfined compression test which let strain rate change with true rock, and the creep test which the constant was used, and estimated breaking time was done. As a result, the estimation of breaking time by Okubo model almost suffered according to the estimation although a variation of test-piece influenced it. (2) A tunnel model apparatus was produced in the purpose which grasped near field bedrock behavior, and it was tested. Simulation rock test body of 1 m * 1 m * 0.5 m was used for a test, and 15 cm tunnel excavation was carried out in an initial stress bottom. Quantities of inner space displacement were measured in a test, and a hardness-test was done after dismantlement, and looseness area was grasped quantitatively. As a result, the looseness area was able to be estimated with about 17.5 cm than tunnel center position. (3) A test approach in deep underground laboratory was examined, and examination/the in situ test which took advantage of rock core analysis/borehole as purpose and done examination item by grip of long-term bedrock behavior (a bord is taken advantage of, and bord itself is used) was shown. In addition, layout of the deep underground laboratory which carried out various tests about long-term behavior in 3 depth was shown. (author)

  19. 241-AZ-101 Mixer Pump Demonstration Test Gamma Cart Acceptance Test Procedure and Quality Test Plan (ATP and QTP)

    International Nuclear Information System (INIS)

    WHITE, D.A.

    2000-01-01

    Shop test of the sludge mobilization cart system to be used in the AZ-101 Mixer Pump Demonstration Test Tests hardware and software. This procedure involves testing the Instrumentation involved with the Gamma Cart System, local and remote, including depth indicators, speed controls, interface to data acquisition software and the raising and lowering functions. This Procedure will be performed twice, once for each Gamma Cart System. This procedure does not test the accuracy of the data acquisition software

  20. 241-AZ-101 Mixer Pump Demonstration Test Gamma Cart Acceptance Test Procedure and Quality Test Plan (ATP and QTP)

    International Nuclear Information System (INIS)

    WHITE, D.A.

    2000-01-01

    Shop Test of the Gamma Cart System to be used in the AZ-101 Mixer Pump Demonstration Test. Tests hardware and software. This procedure involves testing the Instrumentation involved with the Gamma Cart System, local and remote, including: depth indicators, speed controls, interface to data acquisition software and the raising and lowering functions. This Procedure will be performed twice, once for each Gamma Cart System. This procedure does not test the accuracy of the data acquisition software

  1. Automated analysis of pumping tests; Analise automatizada de testes de bombeamento

    Energy Technology Data Exchange (ETDEWEB)

    Sugahara, Luiz Alberto Nozaki

    1996-01-01

    An automated procedure for analysis of pumping test data performed in groundwater wells is described. A computer software was developed to be used under the Windows operational system. The software allows the choice of 3 mathematical models for representing the aquifer behavior, which are: Confined aquifer (Theis model); Leaky aquifer (Hantush model); unconfined aquifer (Boulton model). The analysis of pumping test data using the proper aquifer model, allows for the determination of the model parameters such as transmissivity, storage coefficient, leakage coefficient and delay index. The computer program can be used for the analysis of data obtained from both pumping tests, with one or more pumping rates, and recovery tests. In the multiple rate case, a de superposition procedure has been implemented in order to obtain the equivalent aquifer response for the first flow rate, which is used in obtaining an initial estimate of the model parameters. Such initial estimate is required in the non-linear regression analysis method. The solutions to the partial differential equations describing the aquifer behavior were obtained in Laplace space, followed by numerical inversion of the transformed solution using the Stehfest algorithm. The data analysis procedure is based on a non-linear regression method by matching the field data to the theoretical response of a selected aquifer model, for a given type of test. A least squared regression analysis method was implemented using either Gauss-Newton or Levenberg-Marquardt procedures for minimization of a objective function. The computer software can also be applied to multiple rate test data in order to determine the non-linear well coefficient, allowing for the computation of the well inflow performance curve. (author)

  2. Infants long-term memory for complex music

    Science.gov (United States)

    Ilari, Beatriz; Polka, Linda; Costa-Giomi, Eugenia

    2002-05-01

    In this study we examined infants' long-term memory for two complex pieces of music. A group of thirty 7.5 month-old infants was exposed daily to one short piano piece (i.e., either the Prelude or the Forlane by Maurice Ravel) for ten consecutive days. Following the 10-day exposure period there was a two-week retention period in which no exposure to the piece occurred. After the retention period, infants were tested on the Headturn Preference Procedure. At test, 8 different excerpts of the familiar piece were mixed with 8 different foil excerpts of the unfamiliar one. Infants showed a significant preference for the familiar piece of music. A control group of fifteen nonexposed infants was also tested and showed no preferences for either piece of music. These results suggest that infants in the exposure group retained the familiar music in their long-term memory. This was demonstrated by their ability to discriminate between the different excerpts of both the familiar and the unfamiliar pieces of music, and by their preference for the familiar piece. Confirming previous findings (Jusczyk and Hohne, 1993; Saffran et al., 2000), in this study we suggest that infants can retain complex pieces of music in their long-term memory for two weeks.

  3. Low-flow operation and testing of pumps in nuclear plants

    International Nuclear Information System (INIS)

    Greenstreet, W.L.

    1989-01-01

    Low-flow operation of centrifugal pumps introduces hydraulic instability and other factors that can cause damage to these machines. The resulting degradation has been studied and recorded for pumps in electric power plants. The objectives of this paper are to (1) describe the damage-producing phenomena, including their sources and consequences; (2) relate these observations to expectations for damage caused by low-flow operation of pumps in nuclear power plants; and (3) assess the utility of low-flow testing. Hydraulic behavior during low-flow operation is reviewed for a typical centrifugal pump stage, and the damage-producing mechanisms are described. Pump monitoring practices, in conjunction with pump performance characteristics, are considered; experience data are reviewed; and the effectiveness of low-flow surveillance monitoring is examined. Degradation caused by low-flow operation is shown to be an important factor, and low-flow surveillance testing is shown to be inadequate. 18 refs., 5 figs., 4 tabs

  4. LONG-TERM OUTCOME IN PEDIATRIC TRICHOTILLOMANIA.

    Science.gov (United States)

    Schumer, Maya C; Panza, Kaitlyn E; Mulqueen, Jilian M; Jakubovski, Ewgeni; Bloch, Michael H

    2015-10-01

    To examine long-term outcome in children with trichotillomania. We conducted follow-up clinical assessments an average of 2.8 ± 0.8 years after baseline evaluation in 30 of 39 children who previously participated in a randomized, double-blind, placebo-controlled trial of N-acetylcysteine (NAC) for pediatric trichotillomania. Our primary outcome was change in hairpulling severity on the Massachusetts General Hospital Hairpulling Hospital Hairpulling Scale (MGH-HPS) between the end of the acute phase and follow-up evaluation. We also obtained secondary measures examining styles of hairpulling, comorbid anxiety and depressive symptoms, as well as continued treatment utilization. We examined both correlates and predictors of outcome (change in MGH-HPS score) using linear regression. None of the participants continued to take NAC at the time of follow-up assessment. No significant changes in hairpulling severity were reported over the follow-up period. Subjects reported significantly increased anxiety and depressive symptoms but improvement in automatic pulling symptoms. Increased hairpulling symptoms during the follow-up period were associated with increased depression and anxiety symptoms and increased focused pulling. Older age and greater focused pulling at baseline assessment were associated with poor long-term prognosis. Our findings suggest that few children with trichotillomania experience a significant improvement in trichotillomania symptoms if behavioral treatments are inaccessible or have failed to produce adequate symptom relief. Our findings also confirm results of previous cross-sectional studies that suggest an increased risk of depression and anxiety symptoms with age in pediatric trichotillomania. Increased focused pulling and older age among children with trichotillomania symptoms may be associated with poorer long-term prognosis. © 2015 Wiley Periodicals, Inc.

  5. Long-term EEG in children.

    Science.gov (United States)

    Montavont, A; Kaminska, A; Soufflet, C; Taussig, D

    2015-03-01

    Long-term video-EEG corresponds to a recording ranging from 1 to 24 h or even longer. It is indicated in the following situations: diagnosis of epileptic syndromes or unclassified epilepsy, pre-surgical evaluation for drug-resistant epilepsy, follow-up of epilepsy or in cases of paroxysmal symptoms whose etiology remains uncertain. There are some specificities related to paediatric care: a dedicated pediatric unit; continuous monitoring covering at least a full 24-hour period, especially in the context of pre-surgical evaluation; the requirement of presence by the parents, technician or nurse; and stronger attachment of electrodes (cup electrodes), the number of which is adapted to the age of the child. The chosen duration of the monitoring also depends on the frequency of seizures or paroxysmal events. The polygraphy must be adapted to the type and topography of movements. It is essential to have at least an electrocardiography (ECG) channel, respiratory sensor and electromyography (EMG) on both deltoids. There is no age limit for performing long-term video-EEG even in newborns and infants; nevertheless because of scalp fragility, strict surveillance of the baby's skin condition is required. In the specific context of pre-surgical evaluation, long-term video-EEG must record all types of seizures observed in the child. This monitoring is essential in order to develop hypotheses regarding the seizure onset zone, based on electroclinical correlations, which should be adapted to the child's age and the psychomotor development. Copyright © 2015. Published by Elsevier SAS.

  6. Long-term governance for sustainability

    International Nuclear Information System (INIS)

    Martell, M.

    2007-01-01

    Meritxell Martell spoke of the long-term aspects of radioactive waste management. She pointed out that decision-making processes need to be framed within the context of sustainability, which means that a balance should be sought between scientific considerations, economic aspects and structural conditions. Focusing on structural aspects, Working Group 3 of COWAM-Spain came to the conclusion that the activity of the regulator is a key factor of long-term management. Another finding is that from a sustainability perspective multi-level governance is more effective for coping with the challenges of radioactive waste management than one tier of government-making decisions. The working group also felt that the current Local Information Committees need to evolve towards more institutionalized and legitimized mechanisms for long-term involvement. Ms. Martell introduced a study comparing the efficiency of economic instruments to advance sustainable development in nuclear communities vs. municipalities in mining areas. The study found that funds transferred to nuclear zones had become a means to facilitate local acceptance of nuclear facilities rather than a means to promote socio-economic development. Another finding is that economic instruments are not sufficient guarantees of sustainable development by themselves; additional preconditions include leadership, vision and entrepreneur-ship on the part of community leaders, private or public investments, among others. Finally, Ms. Martell summarised the challenges faced by the Spanish radioactive waste management programme, which include the need for strategic thinking, designing the future in a participatory fashion, and working with local and regional governments and citizens to devise mechanisms for social learning, economic development and environmental protection. (author)

  7. Long term aspects of uranium tailings management

    International Nuclear Information System (INIS)

    Bragg, K.

    1980-05-01

    This paper sets out the background issues which lead to the development of interim close-out criteria for uranium mill tailings. It places the current state-of-the-art for tailings management into both a national and international perspective and shows why such interim criteria are needed now. There are seven specific criteria proposed dealing with the need to have: passive barriers, limits on surface water recharge, durable systems, long term performance guarantees, limits to access, controls on water and airborne releases and finally to have a knowledge of exposure pathways. This paper is intended to serve as a focus for subsequent discussions with all concerned parties. (auth)

  8. Human Behaviour in Long-Term Missions

    Science.gov (United States)

    1997-01-01

    In this session, Session WP1, the discussion focuses on the following topics: Psychological Support for International Space Station Mission; Psycho-social Training for Man in Space; Study of the Physiological Adaptation of the Crew During A 135-Day Space Simulation; Interpersonal Relationships in Space Simulation, The Long-Term Bed Rest in Head-Down Tilt Position; Psychological Adaptation in Groups of Varying Sizes and Environments; Deviance Among Expeditioners, Defining the Off-Nominal Act in Space and Polar Field Analogs; Getting Effective Sleep in the Space-Station Environment; Human Sleep and Circadian Rhythms are Altered During Spaceflight; and Methodological Approach to Study of Cosmonauts Errors and Its Instrumental Support.

  9. Optimal Long-Term Financial Contracting

    OpenAIRE

    Peter M. DeMarzo; Michael J. Fishman

    2007-01-01

    We develop an agency model of financial contracting. We derive long-term debt, a line of credit, and equity as optimal securities, capturing the debt coupon and maturity; the interest rate and limits on the credit line; inside versus outside equity; dividend policy; and capital structure dynamics. The optimal debt-equity ratio is history dependent, but debt and credit line terms are independent of the amount financed and, in some cases, the severity of the agency problem. In our model, the ag...

  10. Pumping and recovery test analysis of groundwater Well in Martajasah, Bangkalan, Madura

    International Nuclear Information System (INIS)

    Adi Gunawan Muhammad

    2010-01-01

    Martajasah is one of the villages in Bangkalan Region, Madura, which have difficulty of fresh water. This area has a lot of potential that can be developed, particularly the potential of religious tourism. To increase the utilization potential of the region and support the public healthy, in 2007 PPGN - BATAN cooperated with the Government of Bangkalan has made one (I) exploration/production groundwater - wells with the expectation it can meet a demand of fresh water in the Martajasah Village area. To determine the capacity of the wells, the maximum discharge pumping and the optimum discharge pumping from the wells pumping test it is necessary should be conducted, which includes step draw down pumping test, constant rate pumping test and recovery test. The purpose of this activity is to determine amount of well loss, loss of aquifer, well hydraulics equations and the value of the efficiency of wells to determine the optimum and maximum discharge wells and calculate the value of transmissivity / transmissivity (T) from the aquifer. The scope of these activities include the preparation of working equipment, testing of all equipment, measurement of static groundwater table, pumping test, and analysis of pumping test. Based on the result from step draw down test, well hydraulics equations obtained Sw = 0.0079 Q + 0.000003 Q 2 , so that according to the well hydraulics equations are than obtained a maximum pumping discharge (Q max ) = 3.9 liters / second (336.7 m 3 ) / days) with the well efficiency (E) = 89%, so the optimum pumping discharge (Q opt )=3.455 liters / second = 298.52 m 3 /day. Based on the result from constant rate pumping test and recovery test showed adequate transmissivity of wells, i e T = 136.5 m 2 / day = 5.6875 m 2 / hour = 0.094 m 2 /minute. (author)

  11. Long term creep strength of silver alloyed copper

    International Nuclear Information System (INIS)

    Auerkari, P.; Sandlin, S.

    1988-12-01

    The long term creep strength of silver alloyed copper has been estimated using literature creep data for materials with less than 0.1% Ag. The available data was very limited, and it was necessary to test the differences between various data sets and extrapolation methods. Assuming constant stress level and constant or changing temperature, the creep behaviour has been assessed using mainly Larson-Miller and theta-projection approaches. The calculations indicate that the different extrapolation methods and data sources can yield strongly different life estimates. With the available incomplete data the theta projection method may give the conservative life predictions, whereas the Larson-Miller approach grossly overestimates creep life. It is recommended that supplementary data is acquired to better assess the long term creep properties of canisters in repository conditions

  12. New Developments in Long-Term Downhole Monitoring Arrays

    Directory of Open Access Journals (Sweden)

    Jochem Kück

    2006-03-01

    Full Text Available The long-term observation of active geological processes is a major research goal in an increasing number of scientific drilling projects. An extended monitoring phase within a potentially hostile environment (e.g., temperature, pressure, salinity requires new long-lasting and robust instrumentation currently unavailable from either industry or academia. Extended exposure of instrument packages to extreme conditions will typically cause seals to weaken and fail,electronic parts to break under permanent load, and sensors to degrade or develop strong drift. In the framework of scientific exploration, there are currently several major research projects targeting fault zone drilling and in situ measurements to monitor physical and chemical conditions before, during, and after seismic events. Planning has now begun for tool development, testing, and continuous long-term monitoring for the San Andreas Fault Zone Observatory at Depth, SAFOD (Parkfi eld, Calif., U.S.A.; See article on page 32..

  13. Long-Term Hydrologic Monitoring Program, Amchitka Island, Alaska

    International Nuclear Information System (INIS)

    1982-01-01

    The purpose of the Long-Term Hydrologic Monitoring Program for Amchitka Island, Alaska, is to obtain data that will assure the public safety, inform the public, the news media, and the scientific community relative to radiological contamination, and to document compliance with federal, state, and local antipollution requirements. Amchitka's geographical setting, climate, geology, hydrology, and ecology are described. Site history including event information for LONG SHOT in 1965, MILROW in 1969, and CANNIKIN in 1971 is described. Event related contamination has been observed only at the LONG SHOT site. At this site, tritium in concentrations below the drinking water standards has been observed in mud pits and wells in the area adjacent to surface ground zero. The Long-Term Hydrologic Monitoring Program for Amchitka is described. No radioactive venting, significant radioactive leakage, or bioenvironmental damage resulted from any of the nuclear tests on Amchitka

  14. On the very long term delayed behavior of concrete

    International Nuclear Information System (INIS)

    Torrenti, J.M.; Benboudjema, F.; Barre, F.; Gallitre, E.

    2015-01-01

    The prediction of very long-term deformation of prestressed concrete structures is a major challenge considering the service life of these structures. It is therefore necessary to correctly model the delayed behavior of these structures. Using a review of laboratory tests and observations of the delayed behavior of structures (bridges and nuclear power plants), the main conclusions of this work are the following ones. First, very long term creep in laboratory or of real structures seems to be non asymptotic. In the actual Eurocode-2, creep is calculated by means of an asymptotic hyperbolic function while in the recent Model Code 2010 creep is expressed as a combination of an asymptotic and a logarithmic functions. In the latter case the logarithmic function corresponds to basic creep while drying creep is asymptotic. Secondly, using a long test (3 years) in a laboratory is not enough to assess the long term behaviour of a massive structure. We need physical relations for creep in codes in order to predict the delayed behavior of massive structures. Thirdly, the biaxial creep of nuclear power plant could be modelled but using data of the structure itself. This would allow to predict the delayed behavior of these structures. Further work is needed to improve the prediction in the design phase

  15. Fusion reactor high vacuum pumping

    International Nuclear Information System (INIS)

    Sedgley, D.W.; Walthers, C.R.; Jenkins, E.M.

    1992-01-01

    This paper reports on recent experiments which have shown the practicality of using activated carbon (coconut charcoal) at 4K to pump helium and hydrogen isotopes for a fusion reactor. Both speed and capacity for deuterium/helium and tritium/helium-3 mixtures were satisfactory. The long-term effects of tritium on the charcoal/cement system developed by Grumman and LLNL was now known; therefore a program was undertaken to see what, if any, effect long-term tritium exposure has on the cryosorber. Several charcoal on aluminum test samples were subjected to six months exposure of tritium at approximately 77 K. The tritium was scanned several times with a residual gas analyzer and the speed-capacity performance of the samples was measured before, approximately one-third way through, and after the exposure. Modest effects were noted which would not seriously restrict the use of charcoal as a cryosorber for fusion reactor high-vacuum pumping applications

  16. Relation between soil P test values and mobilization of dissolved and particulate P from the plough layer of typical Danish soils from a long-term field experiment with applied P fertilizers

    DEFF Research Database (Denmark)

    Glaesner, N.; Kjaergaard, C.; Rubaek, G. H.

    2013-01-01

    Accumulation of phosphorus (P) in agricultural topsoils can contribute to leaching of P which may cause eutrophication of surface waters. An understanding of P mobilization processes in the plough layer is needed to improve agricultural management strategies. We compare leaching of total dissolved...... and particulate P through the plough layer of a typical Danish sandy loam soil subjected to three different P fertilizer regimes in a long-term field experiment established in 1975. The leaching experiment used intact soil columns (20cm diameter, 20cm high) during unsaturated conditions. The three soils had small...

  17. Microscopic study of rock for estimating long-term behavior

    International Nuclear Information System (INIS)

    Ichikawa, Yasuaki

    2004-02-01

    Micro-structure of rock plays an essential role for their long-term behavior. For understanding long-term characteristics of granite we here present the followings: 1) observation of microcrack initiation and propagation by Conforcal Laser Scanning Microscope (CLSM) under uniaxial compression (before loading and at each loading stage), 2) characterization of the mechanism of microcrack initiation and propagation observed by stereoscopic microscope under uniaxial/triaxial compression and relaxation tests, and 3) a study of strong discontinuity analysis included in the homogenization theory to predict the long-term behavior of micro/macro-level stress for granite. First, CLSM was used to acquire clearly focused three-dimensional images of granite specimens, and observed the change of microscale structure including the mineral configuration under applying uniaxial compression stress. Then though microcracks have ever thought to be initiated and propagated on intergranular boundaries, we understand through the CLSM observation that new microcracks are generated from the ends of pre-existing cracks which are distributed in quartz and biotite. Second, we showed the results of stress-relaxation test of granite specimens observed by an optical microscope under water-saturated triaxial compression condition. Since microcrack generation and propagation play an essential role to predict the long-term behavior of rock, we managed the experiments with careful attention of 1) keeping constant edge-displacement and constant strain in the whole specimen accurately, and 2) measuring the relaxed stress exactly. Next, in order to simulate the experimental results which indicate that initiation and propagation of microcracks control the stress-relaxation phenomenon, we introduce a homogenization analysis procedure together with the strong discontinuity analysis which has recently established the mechanical implication and mathematical foundation. The numerical results show that we can

  18. Craniopharyngioma in Children: Long-term Outcomes

    Science.gov (United States)

    STEINBOK, Paul

    2015-01-01

    The survival rate for childhood craniopharyngioma has been improving, with more long-term survivors. Unfortunately it is rare for the patient to be normal, either from the disease itself or from the effects of treatment. Long-term survivors of childhood craniopharyngioma suffer a number of impairments, which include visual loss, endocrinopathy, hypothalamic dysfunction, cerebrovascular problems, neurologic and neurocognitive dysfunction. Pituitary insufficiency is present in almost 100%. Visual and hypothalamic dysfunction is common. There is a high risk of metabolic syndrome and increased risk of cerebrovascular disease, including stroke and Moyamoya syndrome. Cognitive, psychosocial, and emotional problems are prevalent. Finally, there is a higher risk of premature death among survivors of craniopharyngioma, and often this is not from tumor recurrence. It is important to consider craniopharyngioma as a chronic disease. There is no perfect treatment. The treatment has to be tailored to the individual patient to minimize dysfunction caused by tumor and treatments. So “cure” of the tumor does not mean a normal patient. The management of the patient and family needs multidisciplinary evaluation and should involve ophthalmology, endocrinology, neurosurgery, oncology, and psychology. Furthermore, it is also important to address emotional issues and social integration. PMID:26345668

  19. Institutionalization and Organizational Long-term Success

    Directory of Open Access Journals (Sweden)

    Denise L. Fleck

    2007-05-01

    Full Text Available Institutionalization processes have an ambivalent effect on organizational long-term success. Even though they foster organizational stability and permanence, they also bring about rigidity and resistance to change. As a result, successful organizations are likely to lose their competitive advantage over time. The paper addresses this issue through the investigation of the institutionalization processes of two long-lived companies: General Electric, a firm that has been a long-term success and its rival, Westinghouse, which was broken up after eleven decades of existence. The longitudinal, multilevel analysis of firms and industry has identified two different modes of organizational institutionalization. The reactive mode gives rise to rigidity and change resistance, much like institutional theory predicts; the proactive mode, on the other hand, neutralizes those negative effects of institutionalization processes. In the reactive mode, structure predominates. In the proactive mode, agency plays a major role in organizational institutionalization, and in managing the organization’s relations with the environment, clearly contributing to environmental institutionalization.

  20. Neo bladder long term follow-up

    International Nuclear Information System (INIS)

    Fakhr, I.; Mohamed, A. M.; Moustafa, A.; Al-Sherbiny, M.; Salama, M.

    2013-01-01

    One of the commonest forms of orthotopic bladder substitution for bladder cancer surivors, used in our institute, is the use of ileocecal segment. Sometimes, the need for Indiana pouch heterotropic continent diversion arises. Aim: To compare the long-term effect of orthotopic ileocecal bladder and heterotropic Indiana pouch following radical cystectomy in bladder cancer patients. Patients and methods: Between January 2008 and December 2011, 91 patients underwent radical cystectomy/anterior pelvic exentration and ortho topic ileocecal bladder reconstruction (61 patients) and Indiana pouch (30 patients), when orthotopic diversion could not be technically or oncologically feasible. Results: Convalescence was uneventful in most patients. All minor and major urinary leakage cases, in both diversions groups, where successfully conservatively treated. Only one patient in the ileocecal group with major urinary leak required re-exploration with successful revision of uretro-colonic anastomosis. Only one patient in the Indiana pouch group had accidentally discovered sub-centimetric stone, which was simply expelled. The overall survival proportion of ileocecal group was 100% compared to 80% in the Indiana pouch group (p < 0.001). The disease free survival proportion of ileocecal group was 90.8% compared to 80% in the Indiana pouch group (p = 0.076). Effective comparative daytime and nighttime urinary continence as well as renal function deterioration were not statistically significant between both reconstruction types. Conclusion: Both ileocecal bladder and Indiana pouch are safe procedures in regard to long-term effects over kidney function following radical cystectomy

  1. Toward a comprehensive long term nicotine policy.

    Science.gov (United States)

    Gray, N; Henningfield, J E; Benowitz, N L; Connolly, G N; Dresler, C; Fagerstrom, K; Jarvis, M J; Boyle, P

    2005-06-01

    Global tobacco deaths are high and rising. Tobacco use is primarily driven by nicotine addiction. Overall tobacco control policy is relatively well agreed upon but a long term nicotine policy has been less well considered and requires further debate. Reaching consensus is important because a nicotine policy is integral to the target of reducing tobacco caused disease, and the contentious issues need to be resolved before the necessary political changes can be sought. A long term and comprehensive nicotine policy is proposed here. It envisages both reducing the attractiveness and addictiveness of existing tobacco based nicotine delivery systems as well as providing alternative sources of acceptable clean nicotine as competition for tobacco. Clean nicotine is defined as nicotine free enough of tobacco toxicants to pass regulatory approval. A three phase policy is proposed. The initial phase requires regulatory capture of cigarette and smoke constituents liberalising the market for clean nicotine; regulating all nicotine sources from the same agency; and research into nicotine absorption and the role of tobacco additives in this process. The second phase anticipates clean nicotine overtaking tobacco as the primary source of the drug (facilitated by use of regulatory and taxation measures); simplification of tobacco products by limitation of additives which make tobacco attractive and easier to smoke (but tobacco would still be able to provide a satisfying dose of nicotine). The third phase includes a progressive reduction in the nicotine content of cigarettes, with clean nicotine freely available to take the place of tobacco as society's main nicotine source.

  2. Long term ground movement of TRISTAN synchrotron

    International Nuclear Information System (INIS)

    Endo, K.; Ohsawa, Y.; Miyahara, M.

    1989-01-01

    The long term ground movement is estimated through the geological survey before a big accelerator is planned. For the case of TRISTAN-MR (main ring), its site was surveyed to reflect the underground information to the building prior to the construction. The movement of the synchrotron magnet mainly results from the structure of the tunnel. If an individual movement of the magnet exceeds a certain threshold limit, it gives a significant effect on the particle behavior in a synchrotron. Height of the quadrupole magnets were observed periodically during past two years at the TRISTAN-MR and their height differences along the 3 km circumference of the accelerator ring were decomposed into the Fourier components depicting the causes of the movements. Results shows the movement of the tunnel foundation which was also observed by the simultaneous measurement of both magnets and fiducial marks on the tunnel wall. The long term movement of the magnets is summarized with the geological survey prior to construction. 1 ref., 6 figs., 1 tab

  3. Andra long term memory project - 59277

    International Nuclear Information System (INIS)

    Charton, Patrick; Boissier, Fabrice; Martin, Guillaume

    2012-01-01

    Document available in abstract form only. Full text of publication follows: Long term memory of repositories is required by safety, reversibility and social expectations. Thus Andra has implemented since 2010 a long-term memory project to reinforce and diversify its current arrangements in this field, as well as to explore opportunities to extend memory keeping over thousands years. The project includes opportunity studies of dedicated facilities. The 'Ecotheque' and 'Geotheque' projects contribute to memory respectively through environmental and geological samples preservation. The options of creating (i) an archive centre for Andra's interim and permanent archives, (ii) an artist center to study the contribution of arts to memory preservation, (iii) a museum of radioactive waste disposal history and technology (radium industry..., sea disposal, current solutions...) are considered. Other studies provided by the project examine our heritage. This includes the continuity of languages and symbolic systems, the continuity of writing and engraving methods, the archaeology of landscapes (memory of the earths evolution, multi-century memory of industrial and agricultural landscapes), the archaeology practices (how might a future archaeologist be interested in our current activity?), the preservation of historical sites and industrial memory, the continuity of institutional organizations, the memory and history of science evolution as well as broad history

  4. Long term creep behavior of concrete

    International Nuclear Information System (INIS)

    Kennedy, T.W.

    1975-01-01

    This report presents the findings of an experimental investigation to evaluate the long term creep behavior of concrete subjected to sustained uniaxial loads for an extended period of time at 75 0 F. The factors investigated were (1) curing time (90, 183, and 365 days); (2) curing history (as-cast and air-dried); and (3) uniaxial stress (600 and 2400 psi). The experimental investigation applied uniaxial compressive loads to cylindrical concrete specimens and measured strains with vibrating wire strain gages that were cast in the concrete specimen along the axial and radial axes. Specimens cured for 90 days prior to loading were subjected to a sustained load for a period of one year, at which time the loads were removed; the specimens which were cured for 183 or 365 days, however, were not unloaded and have been under load for 5 and 4.5 years, respectively. The effect of each of the above factors on the instantaneous and creep behavior is discussed and the long term creep behavior of the specimens cured for 183 or 365 days is evaluated. The findings of these evaluations are summarized. (17 figures, 10 tables) (U.S.)

  5. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''L''. The ATP will be performed after the construction of the PIC skid in the shop

  6. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  7. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''N''. The ATP will be performed after the construction of the PIC skid in the shop

  8. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid W

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''W''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  9. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid V

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control. (PIC) skid designed as ''V''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  10. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''V''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designated as ''V''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  11. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''Q''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  12. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''T''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designated as ''T''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  13. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid T

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing Of the new Pumping Instrumentation and Control (PIC) skid designed as ''T''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  14. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid R

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''R''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  15. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''U''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''U''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  16. The Long-Term Conditions Questionnaire: conceptual framework and item development.

    Science.gov (United States)

    Peters, Michele; Potter, Caroline M; Kelly, Laura; Hunter, Cheryl; Gibbons, Elizabeth; Jenkinson, Crispin; Coulter, Angela; Forder, Julien; Towers, Ann-Marie; A'Court, Christine; Fitzpatrick, Ray

    2016-01-01

    To identify the main issues of importance when living with long-term conditions to refine a conceptual framework for informing the item development of a patient-reported outcome measure for long-term conditions. Semi-structured qualitative interviews (n=48) were conducted with people living with at least one long-term condition. Participants were recruited through primary care. The interviews were transcribed verbatim and analyzed by thematic analysis. The analysis served to refine the conceptual framework, based on reviews of the literature and stakeholder consultations, for developing candidate items for a new measure for long-term conditions. Three main organizing concepts were identified: impact of long-term conditions, experience of services and support, and self-care. The findings helped to refine a conceptual framework, leading to the development of 23 items that represent issues of importance in long-term conditions. The 23 candidate items formed the first draft of the measure, currently named the Long-Term Conditions Questionnaire. The aim of this study was to refine the conceptual framework and develop items for a patient-reported outcome measure for long-term conditions, including single and multiple morbidities and physical and mental health conditions. Qualitative interviews identified the key themes for assessing outcomes in long-term conditions, and these underpinned the development of the initial draft of the measure. These initial items will undergo cognitive testing to refine the items prior to further validation in a survey.

  17. Long-term ecological research in a human-dominated world

    Science.gov (United States)

    G. Philip Robertson; Scott L. Collins; David R. Foster; Nicholas Brokaw; Hugh W. Ducklow; Ted L. Gragson; Corinna Gries; Stephen K. Hamilton; A. David McGuire; John C. Moore; Emily H. Stanley; Robert B. Waide; Mark W. Williams

    2012-01-01

    The US Long Term Ecological Research (LTER) Network enters its fourth decade with a distinguished record of achievement in ecological science. The value of long-term observations and experiments has never been more important for testing ecological theory and for addressing today’s most difficult environmental challenges. The network’s potential for tackling emergent...

  18. Surprises and insights from long-term aquatic datasets and experiments

    Science.gov (United States)

    Walter K. Dodds; Christopher T. Robinson; Evelyn E. Gaiser; Gretchen J.A. Hansen; Heather Powell; Joseph M. Smith; Nathaniel B. Morse; Sherri L. Johnson; Stanley V. Gregory; Tisza Bell; Timothy K. Kratz; William H. McDowell

    2012-01-01

    Long-term research on freshwater ecosystems provides insights that can be difficult to obtain from other approaches. Widespread monitoring of ecologically relevant water-quality parameters spanning decades can facilitate important tests of ecological principles. Unique long-term data sets and analytical tools are increasingly available, allowing for powerful and...

  19. Long-Term Surveillance and Maintenance Plan for the Gnome-Coach, New Mexico, Site

    Energy Technology Data Exchange (ETDEWEB)

    Kreie, Ken [USDOE Office of Legacy Management, Grand Junction, CO (United States); Findlay, Rick [Navarro Research and Engineering, Inc., Grand Junction, CO (United States)

    2016-06-08

    The U.S. Department of Energy (DOE) Office of Legacy Management (LM) prepared this Long-Term Surveillance and Maintenance Plan (LTSMP) for the Gnome-Coach, New Mexico, Site (the Gnome site). The Gnome site is approximately 25 miles east of Carlsbad in Eddy County, New Mexico (Figure 1). The site was the location of a 3-kiloton-yield underground nuclear test and radioisotope groundwater tracer test. The tests resulted in residual contamination and post-detonation features that require long-term oversight. Long-term responsibility for the site was transferred from the DOE National Nuclear Security Administration Nevada Site Office to LM on October 1, 2006. Responsibilities include surveillance, monitoring, and maintenance of institutional controls (ICs) as part of the long-term stewardship of the site. Long-term stewardship is designed to ensure protection of human health and the environment.

  20. Group long-term care insurance: decision-making factors and implications for financing long-term care.

    Science.gov (United States)

    Stum, Marlene S

    2008-01-01

    This study proposes and tests a systemic family decision-making framework to understand group long-term care insurance (LTCI) enrollment decisions. A random sample of public employees who were offered group LTCI as a workplace benefit were examined. Findings reveal very good predictive efficacy for the overall conceptual framework with a pseudo R2 value of .687, and reinforced the contributions of factors within the family system. Enrollees were more likely to have discussed the decision with others, used information sources, and had prior experience when compared to non-enrollees. Perceived health status, financial knowledge, attitudes regarding the role of private insurance, risk taking, and coverage features were additional factors related to enrollment decisions. The findings help to inform policymakers about the potential of LTCI as one strategy for financing long-term care.