WorldWideScience

Sample records for loading rates rutledge

  1. Torque and Axial Loading Physics for Measuring Atmospheric Icing Load and Icing Rate

    OpenAIRE

    Mughal, Umair Najeeb; Virk, Muhammad Shakeel

    2015-01-01

    Measuring icing load and icing rate are important parameters for an atmospheric icing sensor. A new icing sensor has recently been designed and developed at Narvik University College for measuring atmospheric icing rate, icing load and icing type. Unlike the existing atmospheric icing sensors commercially available in market, which uses the axial loading for measuring icing load and icing rate, this new sensory system measures icing load and icing rate using the torque loading physics. The pe...

  2. Working memory load modulates microsaccadic rate.

    Science.gov (United States)

    Dalmaso, Mario; Castelli, Luigi; Scatturin, Pietro; Galfano, Giovanni

    2017-03-01

    Microsaccades are tiny eye movements that individuals perform unconsciously during fixation. Despite that the nature and the functions of microsaccades are still lively debated, recent evidence has shown an association between these micro eye movements and higher order cognitive processes. Here, in two experiments, we specifically focused on working memory and addressed whether differential memory load could be reflected in a modulation of microsaccade dynamics. In Experiment 1, participants memorized a numerical sequence composed of either two (low-load condition) or five digits (high-load condition), appearing at fixation. The results showed a reduction in the microsaccadic rate in the high-load compared to the low-load condition. In Experiment 2, five red or green digits were always presented at fixation. Participants either memorized the color (low-load condition) or the five digits (high-load condition). Hence, visual stimuli were exactly the same in both conditions. Consistent with Experiment 1, microsaccadic rate was lower in the high-load than in the low-load condition. Overall, these findings reveal that an engagement of working memory can have an impact on microsaccadic rate, consistent with the view that microsaccade generation is pervious to top-down processes.

  3. Impact of measurement uncertainty from experimental load distribution factors on bridge load rating

    Science.gov (United States)

    Gangone, Michael V.; Whelan, Matthew J.

    2018-03-01

    Load rating and testing of highway bridges is important in determining the capacity of the structure. Experimental load rating utilizes strain transducers placed at critical locations of the superstructure to measure normal strains. These strains are then used in computing diagnostic performance measures (neutral axis of bending, load distribution factor) and ultimately a load rating. However, it has been shown that experimentally obtained strain measurements contain uncertainties associated with the accuracy and precision of the sensor and sensing system. These uncertainties propagate through to the diagnostic indicators that in turn transmit into the load rating calculation. This paper will analyze the effect that measurement uncertainties have on the experimental load rating results of a 3 span multi-girder/stringer steel and concrete bridge. The focus of this paper will be limited to the uncertainty associated with the experimental distribution factor estimate. For the testing discussed, strain readings were gathered at the midspan of each span of both exterior girders and the center girder. Test vehicles of known weight were positioned at specified locations on each span to generate maximum strain response for each of the five girders. The strain uncertainties were used in conjunction with a propagation formula developed by the authors to determine the standard uncertainty in the distribution factor estimates. This distribution factor uncertainty is then introduced into the load rating computation to determine the possible range of the load rating. The results show the importance of understanding measurement uncertainty in experimental load testing.

  4. 46 CFR 107.260 - Rated load test for cranes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Rated load test for cranes. 107.260 Section 107.260... INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet the requirements in § 107.231(l), each crane must meet the following rated load test at both the...

  5. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  6. Efficient field testing for load rating railroad bridges

    Science.gov (United States)

    Schulz, Jeffrey L.; Brett C., Commander

    1995-06-01

    As the condition of our infrastructure continues to deteriorate, and the loads carried by our bridges continue to increase, an ever growing number of railroad and highway bridges require load limits. With safety and transportation costs at both ends of the spectrum. the need for accurate load rating is paramount. This paper describes a method that has been developed for efficient load testing and evaluation of short- and medium-span bridges. Through the use of a specially-designed structural testing system and efficient load test procedures, a typical bridge can be instrumented and tested at 64 points in less than one working day and with minimum impact on rail traffic. Various techniques are available to evaluate structural properties and obtain a realistic model. With field data, a simple finite element model is 'calibrated' and its accuracy is verified. Appropriate design and rating loads are applied to the resulting model and stress predictions are made. This technique has been performed on numerous structures to address specific problems and to provide accurate load ratings. The merits and limitations of this approach are discussed in the context of actual examples of both rail and highway bridges that were tested and evaluated.

  7. Rating curve estimation of nutrient loads in Iowa rivers

    Science.gov (United States)

    Stenback, G.A.; Crumpton, W.G.; Schilling, K.E.; Helmers, M.J.

    2011-01-01

    Accurate estimation of nutrient loads in rivers and streams is critical for many applications including determination of sources of nutrient loads in watersheds, evaluating long-term trends in loads, and estimating loading to downstream waterbodies. Since in many cases nutrient concentrations are measured on a weekly or monthly frequency, there is a need to estimate concentration and loads during periods when no data is available. The objectives of this study were to: (i) document the performance of a multiple regression model to predict loads of nitrate and total phosphorus (TP) in Iowa rivers and streams; (ii) determine whether there is any systematic bias in the load prediction estimates for nitrate and TP; and (iii) evaluate streamflow and concentration factors that could affect the load prediction efficiency. A commonly cited rating curve regression is utilized to estimate riverine nitrate and TP loads for rivers in Iowa with watershed areas ranging from 17.4 to over 34,600km2. Forty-nine nitrate and 44 TP datasets each comprising 5-22years of approximately weekly to monthly concentrations were examined. Three nitrate data sets had sample collection frequencies averaging about three samples per week. The accuracy and precision of annual and long term riverine load prediction was assessed by direct comparison of rating curve load predictions with observed daily loads. Significant positive bias of annual and long term nitrate loads was detected. Long term rating curve nitrate load predictions exceeded observed loads by 25% or more at 33% of the 49 measurement sites. No bias was found for TP load prediction although 15% of the 44 cases either underestimated or overestimate observed long-term loads by more than 25%. The rating curve was found to poorly characterize nitrate and phosphorus variation in some rivers. ?? 2010 .

  8. Demonstration of load rating capabilities through physical load testing : Sioux County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  9. Demonstration of load rating capabilities through physical load testing : Johnson County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  10. Demonstration of load rating capabilities through physical load testing : Ida County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  11. Handball load and shoulder injury rate

    DEFF Research Database (Denmark)

    Møller, M.; Nielsen, R.O.; Attermann, J.

    2017-01-01

    Background Knowledge of injury patterns, an essential step towards injury prevention, is lacking in youth handball. Aim To investigate if an increase in handball load is associated with increased shoulder injury rates compared with a minor increase or decrease, and if an association is influenced...... by scapular control, isometric shoulder strength or glenohumeral range of motion (ROM). Methods 679 players (14-18 years) provided weekly reports on shoulder injury and handball load (training and competition hours) over 31 weeks using the SMS, phone and medical examination system. Handball load in a given...... week was categorised into (1) 60% relative to the weekly average amount of handball load the preceding 4 weeks. Assessment of shoulder isometric rotational and abduction strength, ROM and scapular control...

  12. Mechanics of arterial subfailure with increasing loading rate.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2007-01-01

    Arterial subfailure leads to delayed symptomatology and high morbidity and mortality rates, particularly for the thoracic aorta and carotid arteries. Although arterial injuries occur during high-velocity automotive collisions, previous studies of arterial subfailure focused on quasi-static loading. This investigation subjected aortic segments to increasing loading rates to quantify effects on elastic, subfailure, and ultimate vessel mechanics. Sixty-two specimens were axially distracted, and 92% demonstrated subfailure before ultimate failure. With increasing loading rate, stress at initial subfailure and ultimate failure significantly increased, and strain at initial subfailure and ultimate failure significantly decreased. Present results indicate increased susceptibility for arterial subfailure and/or dissection under higher-rate extension. According to the present results, automotive occupants are at greater risk of arterial injury under higher velocity impacts due to greater body segment motions in addition to decreased strain tolerance to subfailure and catastrophic failure.

  13. Loading rates in California inferred from aftershocks

    Directory of Open Access Journals (Sweden)

    C. Narteau

    2008-03-01

    Full Text Available We estimate the loading rate in southern California and the change in stress induced by a transient slip event across the San Andreas fault (SAF system in central California, using a model of static fatigue. We analyze temporal properties of aftershocks in order to determine the time delay before the onset of the power law aftershock decay rate. In creep-slip and stick-slip zones, we show that the rate of change of this delay is related to seismic and aseismic deformation across the SAF system. Furthermore, we show that this rate of change is proportional to the deficit of slip rate along the SAF. This new relationship between geodetic and seismological data is in good agreement with predictions from a Limited Power Law model in which the evolution of the duration of a linear aftershock decay rate over short time results from variations in the load of the brittle upper crust.

  14. Dynamic strength of rock with single planar joint under various loading rates at various angles of loads applied

    Directory of Open Access Journals (Sweden)

    Pei-Yun Shu

    2018-06-01

    Full Text Available Intact rock-like specimens and specimens that include a single, smooth planar joint at various angles are prepared for split Hopkinson pressure bar (SHPB testing. A buffer pad between the striker bar and the incident bar of an SHPB apparatus is used to absorb some of the shock energy. This can generate loading rates of 20.2–4627.3 GPa/s, enabling dynamic peak stresses/strengths and associated failure patterns of the specimens to be investigated. The effects of the loading rate and angle of load applied on the dynamic peak stresses/strengths of the specimens are examined. Relevant experimental results demonstrate that the failure pattern of each specimen can be classified as four types: Type A, integrated with or without tiny flake-off; Type B, slide failure; Type C, fracture failure; and Type D, crushing failure. The dynamic peak stresses/strengths of the specimens that have similar failure patterns increase linearly with the loading rate, yielding high correlations that are evident on semi-logarithmic plots. The slope of the failure envelope is the smallest for slide failure, followed by crushing failure, and that of fracture failure is the largest. The magnitude of the plot slope of the dynamic peak stress against the loading rate for the specimens that are still integrated after testing is between that of slide failure and crushing failure. The angle of application has a limited effect on the dynamic peak stresses/strengths of the specimens regardless of the failure pattern, but it affects the bounds of the loading rates that yield each failure pattern, and thus influences the dynamic responses of the single jointed specimen. Slide failure occurs at the lowest loading rate of any failure, but can only occur in single jointed specimen that allows sliding. Crushing failure is typically associated with the largest loading rate, and fracture failure may occur when the loading rate is between the boundaries for slide failure and crushing

  15. Increased strength of concrete subject to high loading rates

    International Nuclear Information System (INIS)

    Curbach, M.

    1987-01-01

    Within the scope of this work various problems are discussed which occur in connection with concrete under high tensile loading rates (e.g. when a plane crashes on a nuclear power plant very high loads occur which act only for a very short time). Particularly the causes for the already frequently noticed increases in strength with increasing loading rates are investigated and also the question whether this increased strength can be taken into account when dimensioning a construction. (MM) [de

  16. An analysis of representative heating load lines for residential HSPF ratings

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-07-01

    This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28

  17. High rate loading tests and impact tests of concrete and reinforcement

    International Nuclear Information System (INIS)

    Takeda, J.I.; Tachikawa, H.; Fujimoto, K.

    1982-01-01

    The responses of reinforced concrete structural members and structures subjected to impact or impulsive loadings are affected by the behavior of constituent concrete and reinforcement which are the synthesis of the rate effects and the contribution of propagating stress waves of them. The rate effects and the contribution of stress waves do not have the same tendency in the variation of magnitude of them with speed of impact or impulsive loadings. Therefore the rate effects, mentioned above, should be obtained by the tests minimized the effect of stress waves (high rate loading test). This paper deals with the testing techniques with high rate loadings and impact, and also reports the main results of these tests. (orig.) [de

  18. The effect of rehearsal rate and memory load on verbal working memory.

    Science.gov (United States)

    Fegen, David; Buchsbaum, Bradley R; D'Esposito, Mark

    2015-01-15

    While many neuroimaging studies have investigated verbal working memory (WM) by manipulating memory load, the subvocal rehearsal rate at these various memory loads has generally been left uncontrolled. Therefore, the goal of this study was to investigate how mnemonic load and the rate of subvocal rehearsal modulate patterns of activity in the core neural circuits underlying verbal working memory. Using fMRI in healthy subjects, we orthogonally manipulated subvocal rehearsal rate and memory load in a verbal WM task with long 45-s delay periods. We found that middle frontal gyrus (MFG) and superior parietal lobule (SPL) exhibited memory load effects primarily early in the delay period and did not exhibit rehearsal rate effects. In contrast, we found that inferior frontal gyrus (IFG), premotor cortex (PM) and Sylvian-parietal-temporal region (area Spt) exhibited approximately linear memory load and rehearsal rate effects, with rehearsal rate effects lasting through the entire delay period. These results indicate that IFG, PM and area Spt comprise the core articulatory rehearsal areas involved in verbal WM, while MFG and SPL are recruited in a general supervisory role once a memory load threshold in the core rehearsal network has been exceeded. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Loading rate effect on the fracture behaviour of highstrength concrete

    Directory of Open Access Journals (Sweden)

    Del Viso J.

    2010-06-01

    Full Text Available This research deals with the sensitivity of eight types of performancedesigned high-strength concrete to the loading rate. Variations in the composition of the concrete produce the desired performance, for instance having null shrinkage or being able to be pumped at elevated heights without segregation, but they also produce variations in the fracture properties that are reported in this paper. We performed tests at five loading rates spanning six orders of magnitude in the displacement rate, from 1.74 × 10-5 mm/s to 17.4 mm/s. Load-displacement curves show that their peak is higher as the displacement rate increases, whereas the corresponding displacement is almost constant. Fracture energy also increases, but only for loading rates higher than 0.01 mm/s. We use a formula based on a cohesive law with a viscous term to study the results. The correlation of the formula to the experimental results is good and it allows us to obtain the theoretical value for the fracture energy under strictly static conditions. In addition, both the fracture energy and the characteristic length of the concretes used in the study diminish as the compressive strength of their aggregates increases.

  20. Sound-Intensity Feedback During Running Reduces Loading Rates and Impact Peak.

    Science.gov (United States)

    Tate, Jeremiah J; Milner, Clare E

    2017-08-01

    Study Design Controlled laboratory study, within-session design. Background Gait retraining has been proposed as an effective intervention to reduce impact loading in runners at risk of stress fractures. Interventions that can be easily implemented in the clinic are needed. Objective To assess the immediate effects of sound-intensity feedback related to impact during running on vertical impact peak, peak vertical instantaneous loading rate, and vertical average loading rate. Methods Fourteen healthy, college-aged runners who ran at least 9.7 km/wk participated (4 male, 10 female; mean ± SD age, 23.7 ± 2.0 years; height, 1.67 ± 0.08 m; mass, 60.9 ± 8.7 kg). A decibel meter provided real-time sound-intensity feedback of treadmill running via an iPad application. Participants were asked to reduce the sound intensity of running while receiving continuous feedback for 15 minutes, while running at their self-selected preferred speed. Baseline and follow-up ground reaction force data were collected during overground running at participants' self-selected preferred running speed. Results Dependent t tests indicated a statistically significant reduction in vertical impact peak (1.56 BW to 1.13 BW, P≤.001), vertical instantaneous loading rate (95.48 BW/s to 62.79 BW/s, P = .001), and vertical average loading rate (69.09 BW/s to 43.91 BW/s, P≤.001) after gait retraining, compared to baseline. Conclusion The results of the current study support the use of sound-intensity feedback during treadmill running to immediately reduce loading rate and impact force. The transfer of within-session reductions in impact peak and loading rates to overground running was demonstrated. Decreases in loading were of comparable magnitude to those observed in other gait retraining methods. J Orthop Sports Phys Ther 2017;47(8):565-569. Epub 6 Jul 2017. doi:10.2519/jospt.2017.7275.

  1. Effect of loading rate on the compressive mechanics of the immature baboon cervical spine.

    Science.gov (United States)

    Elias, Paul Z; Nuckley, David J; Ching, Randal P

    2006-02-01

    Thirty-four cervical spine segments were harvested from 12 juvenile male baboons and compressed to failure at displacement rates of 5, 50, 500, or 5000 mm/s. Compressive stiffness, failure load, and failure displacement were measured for comparison across loading rate groups. Stiffness showed a significant concomitant increase with loading rate, increasing by 62% between rates of 5 and 5000 mm/s. Failure load also demonstrated an increasing relationship with loading rate, while displacement at failure showed no rate dependence. These data may help in the development of improved pediatric automotive safety standards and more biofidelic physical and computational models.

  2. The Effect of Rehearsal Rate and Memory Load on Verbal Working Memory

    OpenAIRE

    Fegen, David; Buchsbaum, Bradley R.; D’Esposito, Mark

    2014-01-01

    While many neuroimaging studies have investigated verbal working memory (WM) by manipulating memory load, the subvocal rehearsal rate at these various memory loads has generally been left uncontrolled. Therefore, the goal of this study was to investigate how mnemonic load and the rate of subvocal rehearsal modulate patterns of activity in the core neural circuits underlying verbal working memory. Using fMRI in healthy subjects, we orthogonally manipulated subvocal rehearsal rate and memory lo...

  3. Laboratory investigation of the loading rate effects in sand

    NARCIS (Netherlands)

    Huy, N.Q.; Van Tol, A.F.; Hölscher, P.

    2006-01-01

    In order to improve the interpretation of the quasi-static (e.g. Statnamic) pile load tests, a research project has been started to investigate effects of the loading rate on the bearing capacity of a pile in sand. A series of laboratory tests has been carried out. The testing program consists of a

  4. Experimental investigation of bond strength under high loading rates

    Directory of Open Access Journals (Sweden)

    Michal Mathias

    2015-01-01

    Full Text Available The structural behaviour of reinforced concrete is governed significantly by the transmission of forces between steel and concrete. The bond is of special importance for the overlapping joint and anchoring of the reinforcement, where rigid bond is required. It also plays an important role in the rotational capacity of plastic hinges, where a ductile bond behaviour is preferable. Similar to the mechanical properties of concrete and steel also the characteristics of their interaction changes with the velocity of the applied loading. For smooth steel bars with its main bond mechanisms of adhesion and friction, nearly no influence of loading rate is reported in literature. In contrast, a high rate dependence can be found for the nowadays mainly used deformed bars. For mechanical interlock, where ribs of the reinforcing steel are bracing concrete material surrounding the bar, one reason can be assumed to be in direct connection with the increase of concrete compressive strength. For splitting failure of bond, characterized by the concrete tensile strength, an even higher dynamic increase is observed. For the design of Structures exposed to blast or impact loading the knowledge of a rate dependent bond stress-slip relationship is required to consider safety and economical aspects at the same time. The bond behaviour of reinforced concrete has been investigated with different experimental methods at the University of the Bundeswehr Munich (UniBw and the Joint Research Centre (JRC in Ispra. Both static and dynamic tests have been carried out, where innovative experimental apparatuses have been used. The bond stress-slip relationship and maximum pull-out-forces for varying diameter of the bar, concrete compressive strength and loading rates have been obtained. It is expected that these experimental results will contribute to a better understanding of the rate dependent bond behaviour and will serve for calibration of numerical models.

  5. Canadian House Dust Study: Population-based concentrations, loads and loading rates of arsenic, cadmium, chromium, copper, nickel, lead, and zinc inside urban homes

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Pat E. [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Levesque, Christine [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Chénier, Marc; Gardner, H. David [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Jones-Otazo, Heather [Regions and Programs Branch, Health Canada, 180 Queen Street West, Toronto, ON, Canada M5V 3L7 (Canada); Petrovic, Sanya [Contaminated Sites Division, Healthy Environments and Consumer Safety Branch, Health Canada, 269 Laurier Ave West, Ottawa, ON, Canada K1A 0K9 (Canada)

    2013-01-15

    The Canadian House Dust Study was designed to obtain nationally representative urban house dust metal concentrations (μg g{sup −1}) and metal loadings (μg m{sup −2}) for arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn). Consistent sampling of active dust of known age and provenance (area sampled) also permitted the calculation of indoor loading rates (mg m{sup −2} day{sup −1} for dust and μg m{sup −2} day{sup −1} for metals) for the winter season (from 2007 to 2010) when houses are most tightly sealed. Geomean/median indoor dust loading rates in homes located more than 2 km away from industry of any kind (9.6/9.1 mg m{sup −2} day{sup −1}; n = 580) were significantly lower (p < .001) than geomean (median) dust loading rates in homes located within 2 km of industry (13.5/13.4 mg m{sup −2} day{sup −1}; n = 421). Proximity to industry was characterized by higher indoor metal loading rates (p < .003), but no difference in dust metal concentrations (.29 ≥ p ≤ .97). Comparisons of non-smokers' and smokers' homes in non-industrial zones showed higher metal loading rates (.005 ≥ p ≤ .038) in smokers' homes, but no difference in dust metal concentrations (.15 ≥ p ≤ .97). Relationships between house age and dust metal concentrations were significant for Pb, Cd and Zn (p < .001) but not for the other four metals (.14 ≥ p ≤ .87). All seven metals, however, displayed a significant increase in metal loading rates with house age (p < .001) due to the influence of higher dust loading rates in older homes (p < .001). Relationships between three measures of metals in house dust – concentration, load, and loading rate – in the context of house age, smoking behavior and urban setting consistently show that concentration data is a useful indicator of the presence of metal sources in the home, whereas dust mass is the overriding influence on metal loadings and loading rates

  6. Behavior of quenched and tempered steels under high strain rate compression loading

    International Nuclear Information System (INIS)

    Meyer, L.W.; Seifert, K.; Abdel-Malek, S.

    1997-01-01

    Two quenched and tempered steels were tested under compression loading at strain rates of ε = 2.10 2 s -1 and ε = 2.10 3 s -1 . By applying the thermal activation theory, the flow stress at very high strain rates of 10 5 to 10 6 s -1 is derived from low temperature and high strain rate tests. Dynamic true stress - true strain behaviour presents, that stress increases with increasing strain until a maximum, then it decreases. Because of the adiabatic process under dynamic loading the maximum flow stress will occur at a lower strain if the strain rate is increased. Considering strain rate, strain hardening, strain rate hardening and strain softening, a constitutive equation with different additive terms is successfully used to describe the behaviour of material under dynamic compression loading. Results are compared with other models of constitutive equations. (orig.)

  7. Optimization between heating load and entropy-production rate for endoreversible absorption heat-transformers

    International Nuclear Information System (INIS)

    Sun Fengrui; Qin Xiaoyong; Chen Lingen; Wu Chih

    2005-01-01

    For an endoreversible four-heat-reservoir absorption heat-transformer cycle, for which a linear (Newtonian) heat-transfer law applies, an ecological optimization criterion is proposed for the best mode of operation of the cycle. This involves maximizing a function representing the compromise between the heating load and the entropy-production rate. The optimal relation between the ecological criterion and the COP (coefficient of performance), the maximum ecological criterion and the corresponding COP, heating load and entropy production rate, as well as the ecological criterion and entropy-production rate at the maximum heating load are derived using finite-time thermodynamics. Moreover, compared with the heating-load criterion, the effects of the cycle parameters on the ecological performance are studied by numerical examples. These show that achieving the maximum ecological criterion makes the entropy-production rate decrease by 77.0% and the COP increase by 55.4% with only 27.3% heating-load losses compared with the maximum heating-load objective. The results reflect that the ecological criterion has long-term significance for optimal design of absorption heat-transformers

  8. Study of Acoustic Emission and Mechanical Characteristics of Coal Samples under Different Loading Rates

    Directory of Open Access Journals (Sweden)

    Huamin Li

    2015-01-01

    Full Text Available To study the effect of loading rate on mechanical properties and acoustic emission characteristics of coal samples, collected from Sanjiaohe Colliery, the uniaxial compression tests are carried out under various levels of loading rates, including 0.001 mm/s, 0.002 mm/s, and 0.005 mm/s, respectively, using AE-win E1.86 acoustic emission instrument and RMT-150C rock mechanics test system. The results indicate that the loading rate has a strong impact on peak stress and peak strain of coal samples, but the effect of loading rate on elasticity modulus of coal samples is relatively small. When the loading rate increases from 0.001 mm/s to 0.002 mm/s, the peak stress increases from 22.67 MPa to 24.99 MPa, the incremental percentage is 10.23%, and under the same condition the peak strain increases from 0.006191 to 0.007411 and the incremental percentage is 19.71%. Similarly, when the loading rate increases from 0.002 mm/s to 0.005 mm/s, the peak stress increases from 24.99 MPa to 28.01 MPa, the incremental percentage is 12.08%, the peak strain increases from 0.007411 to 0.008203, and the incremental percentage is 10.69%. The relationship between acoustic emission and loading rate presents a positive correlation, and the negative correlation relation has been determined between acoustic emission cumulative counts and loading rate during the rupture process of coal samples.

  9. Association between increase in vertical ground reaction force loading rate and pain level in women with patellofemoral pain after a patellofemoral joint loading protocol.

    Science.gov (United States)

    Briani, Ronaldo Valdir; Pazzinatto, Marcella Ferraz; Waiteman, Marina Cabral; de Oliveira Silva, Danilo; de Azevedo, Fábio Mícolis

    2018-04-11

    The etiology of patellofemoral pain (PFP) is thought to be the result of increased patellofemoral joint (PFJ) load and aberrant lower extremity mechanics, including altered vertical ground reaction forces (VGRF). However, few studies have investigated the association between an increase in pain and VGRF loading rates in the context of PFP. Thus, this study aimed to investigate the immediate effects of PFJ loading on pain and VGRF loading rate, and to see if there is a link between modification of both pain and VGRF loading rate during stair negotiation. Thirty-four women with PFP underwent VGRF analysis during stair negotiation under two conditions: with (condition 2) and without (condition 1) being previously submitted to a PFJ loading protocol in order to or not to exacerbate their knee pain, respectively. The VGRF loading rates were significantly higher in condition 2 (Mean ± standard deviation (SD)=4.0±0.6N/s) compared to condition 1 (Mean±SD=3.6±0.5N/s) during stair ascent and during stair descent (Mean±SD: condition 1=6.3±1.1N/s; condition 2=7.0±1.4N/s). In addition, VGRF loading rates were higher during stair descent compared to stair ascent in both conditions. There were significant correlations between the increase in pain and VGRF loading rate during both tasks. There seemed to be an important relation between the increase in pain and VGRF loading rates in women with PFP. Based on these findings, interventions aimed at reducing VGRF loading rates are important in the context of PFP. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Brittle materials at high-loading rates: an open area of research

    Science.gov (United States)

    Forquin, Pascal

    2017-01-01

    Brittle materials are extensively used in many civil and military applications involving high-strain-rate loadings such as: blasting or percussive drilling of rocks, ballistic impact against ceramic armour or transparent windshields, plastic explosives used to damage or destroy concrete structures, soft or hard impacts against concrete structures and so on. With all of these applications, brittle materials are subjected to intense loadings characterized by medium to extremely high strain rates (few tens to several tens of thousands per second) leading to extreme and/or specific damage modes such as multiple fragmentation, dynamic cracking, pore collapse, shearing, mode II fracturing and/or microplasticity mechanisms in the material. Additionally, brittle materials exhibit complex features such as a strong strain-rate sensitivity and confining pressure sensitivity that justify expending greater research efforts to understand these complex features. Currently, the most popular dynamic testing techniques used for this are based on the use of split Hopkinson pressure bar methodologies and/or plate-impact testing methods. However, these methods do have some critical limitations and drawbacks when used to investigate the behaviour of brittle materials at high loading rates. The present theme issue of Philosophical Transactions A provides an overview of the latest experimental methods and numerical tools that are currently being developed to investigate the behaviour of brittle materials at high loading rates. This article is part of the themed issue 'Experimental testing and modelling of brittle materials at high strain rates'.

  11. Degradation of isobutanal at high loading rates in a compost biofilter.

    Science.gov (United States)

    Sercu, Bram; Demeestere, Kristof; Baillieul, Hans; Van Langenhove, Herman; Verstraete, Willy

    2005-08-01

    Biofiltration has been increasingly used for cleaning waste gases, mostly containing low concentrations of odorous compounds. To expand the application area of this technology, the biofiltration of higher pollutant loading rates has to be investigated. This article focuses on the biodegradation of isobutanal (IBAL) in a compost biofilter (BF) at mass loading rates between 211 and 4123 g/m3/day (30-590 ppm(v)). At mass loading rates up to 785 g/m3/day, near 100% removal efficiencies could be obtained. However, after increasing the loading rate to 1500-1900 g/m3/ day, the degradation efficiency decreased to 62-98%. In addition, a pH decrease and production of isobutanol (IBOL) and isobutyric acid (IBAC) were observed. This is the first report showing that an aldehyde can act as electron donor as well as acceptor in a BF. To study the effects of pH, compost moisture content, and electron acceptor availability on the biofiltration of IBAL, IBOL, and IBAC, additional batch and continuous experiments were performed. A pH of 5.2 reduced the IBAL degradation rate and inhibited the IBOL degradation, although adaptation of the microorganisms to low pH was observed in the BFs. IBAC was not degraded in the batch experiments. High moisture content (51%) initially had no effect on the IBOL production, although it negatively affected the IBAL elimination increasingly during a 21-day time-course experiment. In batch experiments, the reduction of IBAL to IBOL did not decrease when the amount of available electron acceptors (oxygen or nitrate) was increased. The IBAL removal efficiency at higher loading rates was limited by a combination of nutrient limitation, pH decrease, and dehydration, and the importance of each limiting factor depended on the influent concentration.

  12. Sigh rate and respiratory variability during mental load and sustained attention.

    Science.gov (United States)

    Vlemincx, Elke; Taelman, Joachim; De Peuter, Steven; Van Diest, Ilse; Van den Bergh, Omer

    2011-01-01

    Spontaneous breathing consists of substantial correlated variability: Parameters characterizing a breath are correlated with parameters characterizing previous and future breaths. On the basis of dynamic system theory, negative emotion states are predicted to reduce correlated variability whereas sustained attention is expected to reduce total respiratory variability. Both are predicted to evoke sighing. To test this, respiratory variability and sighing were assessed during a baseline, stressful mental arithmetic task, nonstressful sustained attention task, and recovery in between tasks. For respiration rate (excluding sighs), reduced total variability was found during the attention task, whereas correlated variation was reduced during mental load. Sigh rate increased during mental load and during recovery from the attention task. It is concluded that mental load and task-related attention show specific patterns in respiratory variability and sigh rate. Copyright © 2010 Society for Psychophysiological Research.

  13. Brittle materials at high-loading rates: an open area of research

    Science.gov (United States)

    2017-01-01

    Brittle materials are extensively used in many civil and military applications involving high-strain-rate loadings such as: blasting or percussive drilling of rocks, ballistic impact against ceramic armour or transparent windshields, plastic explosives used to damage or destroy concrete structures, soft or hard impacts against concrete structures and so on. With all of these applications, brittle materials are subjected to intense loadings characterized by medium to extremely high strain rates (few tens to several tens of thousands per second) leading to extreme and/or specific damage modes such as multiple fragmentation, dynamic cracking, pore collapse, shearing, mode II fracturing and/or microplasticity mechanisms in the material. Additionally, brittle materials exhibit complex features such as a strong strain-rate sensitivity and confining pressure sensitivity that justify expending greater research efforts to understand these complex features. Currently, the most popular dynamic testing techniques used for this are based on the use of split Hopkinson pressure bar methodologies and/or plate-impact testing methods. However, these methods do have some critical limitations and drawbacks when used to investigate the behaviour of brittle materials at high loading rates. The present theme issue of Philosophical Transactions A provides an overview of the latest experimental methods and numerical tools that are currently being developed to investigate the behaviour of brittle materials at high loading rates. This article is part of the themed issue ‘Experimental testing and modelling of brittle materials at high strain rates’. PMID:27956517

  14. Footwear Matters: Influence of Footwear and Foot Strike on Load Rates during Running.

    Science.gov (United States)

    Rice, Hannah M; Jamison, Steve T; Davis, Irene S

    2016-12-01

    Running with a forefoot strike (FFS) pattern has been suggested to reduce the risk of overuse running injuries, due to a reduced vertical load rate compared with rearfoot strike (RFS) running. However, resultant load rate has been reported to be similar between foot strikes when running in traditional shoes, leading to questions regarding the value of running with a FFS. The influence of minimal footwear on the resultant load rate has not been considered. This study aimed to compare component and resultant instantaneous loading rate (ILR) between runners with different foot strike patterns in their habitual footwear conditions. Twenty-nine injury-free participants (22 men, seven women) ran at 3.13 m·s along a 30-m runway, with their habitual foot strike and footwear condition. Ground reaction force data were collected. Peak ILR values were compared between three conditions; those who habitually run with an RFS in standard shoes, with an FFS in standard shoes, and with an FFS in minimal shoes. Peak resultant, vertical, lateral, and medial ILR were lower (P strike. When running with an FFS, peak posterior ILR were lower (P strike. Therefore, it appears that footwear alters the load rates during running, even with similar foot strike patterns.

  15. Measurement of blowdown flow rates using load cells

    International Nuclear Information System (INIS)

    Dolas, P.K.; Venkat Raj, V.; Ghosh, A.K.; Murty, L.G.K.; Muralidhar Rao, S.

    1980-01-01

    To establish a reliable method for measuring two-phase flow, experiments were planned for measurement of transient single phase flow rates from vessels using load cells. Suitability of lead-zirconate-titanate piezoelectric ceramic discs was examined. Discharge time constant of the disc used was low, leading to large measurement errors. Subsequently, experiments were carried out using strain gauge load cells and these were found satisfactory. The unsteady flow equation has been derived for the system under investigation. The equation has been solved numerically using the fourth order Runge-Kutta method and also by integrating it analytically. The experimental results are compared with the theoretical results and presented in this report. (auth.)

  16. Probing the impact of loading rate on the mechanical properties of viral nanoparticles

    NARCIS (Netherlands)

    Snijder, J.; Ivanovska, I.L.; Baclayon, M.; Roos, W.H.; Wuite, G.J.L.

    2012-01-01

    The effects of changes in the loading rate during the forced dissociation of single bonds have been studied for a wide variety of interactions. Less is known on the loading rate dependent behaviour of more complex systems that consist of multiple bonds. Here we focus on viral nanoparticles, in

  17. Effects of age and loading rate on equine cortical bone failure.

    Science.gov (United States)

    Kulin, Robb M; Jiang, Fengchun; Vecchio, Kenneth S

    2011-01-01

    Although clinical bone fractures occur predominantly under impact loading (as occurs during sporting accidents, falls, high-speed impacts or other catastrophic events), experimentally validated studies on the dynamic fracture behavior of bone, at the loading rates associated with such events, remain limited. In this study, a series of tests were performed on femoral specimens obtained post-mortem from equine donors ranging in age from 6 months to 28 years. Fracture toughness and compressive tests were performed under both quasi-static and dynamic loading conditions in order to determine the effects of loading rate and age on the mechanical behavior of the cortical bone. Fracture toughness experiments were performed using a four-point bending geometry on single and double-notch specimens in order to measure fracture toughness, as well as observe differences in crack initiation between dynamic and quasi-static experiments. Compressive properties were measured on bone loaded parallel and transverse to the osteonal growth direction. Fracture propagation was then analyzed using scanning electron and scanning confocal microscopy to observe the effects of microstructural toughening mechanisms at different strain rates. Specimens from each horse were also analyzed for dry, wet and mineral densities, as well as weight percent mineral, in order to investigate possible influences of composition on mechanical behavior. Results indicate that bone has a higher compressive strength, but lower fracture toughness when tested dynamically as compared to quasi-static experiments. Fracture toughness also tends to decrease with age when measured quasi-statically, but shows little change with age under dynamic loading conditions, where brittle "cleavage-like" fracture behavior dominates. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Analyzing the effects of mechanical and osmotic loading on glycosaminoglycan synthesis rate in cartilaginous tissues.

    Science.gov (United States)

    Gao, Xin; Zhu, Qiaoqiao; Gu, Weiyong

    2015-02-26

    The glycosaminoglycan (GAG) plays an important role in cartilaginous tissues to support and transmit mechanical loads. Many extracellular biophysical stimuli could affect GAG synthesis by cells. It has been hypothesized that the change of cell volume is a primary mechanism for cells to perceive the stimuli. Experimental studies have shown that the maximum synthesis rate of GAG is achieved at an optimal cell volume, larger or smaller than this level the GAG synthesis rate decreases. Based on the hypothesis and experimental findings in the literature, we proposed a mathematical model to quantitatively describe the cell volume dependent GAG synthesis rate in the cartilaginous tissues. Using this model, we investigated the effects of osmotic loading and mechanical loading on GAG synthesis rate. It is found our proposed mathematical model is able to well describe the change of GAG synthesis rate in isolated cells or in cartilage with variations of the osmotic loading or mechanical loading. This model is important for evaluating the GAG synthesis activity within cartilaginous tissues as well as understanding the role of mechanical loading in tissue growth or degeneration. It is also important for designing a bioreactor system with proper extracellular environment or mechanical loading for growing tissue at the maximum synthesis rate of the extracellular matrix. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Photovoltaic systems for Malaysian islands: Effects of interest rates, diesel prices and load sizes

    International Nuclear Information System (INIS)

    Lau, K.Y.; Tan, C.W.; Yatim, A.H.M.

    2015-01-01

    Standalone diesel systems have been widely used on Malaysian islands due to the isolated locations of the islands. Nevertheless, the high diesel prices and the high cost of transporting diesel to islands cause the use of standalone diesel systems to be uneconomical. This study analyzes the feasibility of implementing PV (photovoltaic) systems as alternatives to standalone diesel systems by considering the effects of annual real interest rates, diesel prices and load sizes, using the HOMER (hybrid optimization of multiple energy resources) software. The results indicate that, at the ordinary diesel price of $ 0.61/L, low interest rates (0–3%) are desirable for the implementation of hybrid PV/diesel with battery systems over standalone diesel systems, regardless of the load sizes. Although different load sizes may affect the decisions on the implementation of PV systems at higher interest rates (6–9%), these effects become less pronounced as the price of diesel increases to $ 1.22/L or higher. Also, under high diesel prices, the choice of optimal system configurations obtained for small load sizes should be applicable for larger load sizes, albeit with different component ratings. Although the current study is intended for Malaysian islands, the findings can be generalized for other places with similar solar radiation levels. - Highlights: • Photovoltaic systems for Malaysian islands have been analyzed using HOMER. • Interest rates, diesel prices and load sizes affect optimal system configurations. • Effects of interest rates and load sizes reduce with increasing diesel prices. • Photovoltaic systems' implementation is feasible at high diesel prices. • The findings can be generalized for places with similar solar radiation levels

  20. Developing Representative Michigan Truck Configurations for Bridge Load Rating

    Science.gov (United States)

    2018-02-28

    The objective of this study is to recommend a rating process representative of Michigan load effects for legal and extended permit vehicles. For this study, high fidelity WIM data from 20 Michigan sites were analyzed. Using vehicle weight and configu...

  1. Seismic Load Rating Procedure for Welded Steel Frames Oligo-cyclic Fatigue

    International Nuclear Information System (INIS)

    Ratiu, Mircea D.; Moisidis, Nicolae T.

    2004-01-01

    A dynamic load rating approach for seismic qualification of cold-formed steel welded frames is presented. Allowable seismic loads are developed from cyclic and monotonic tests of standard cold-formed steel components commonly used for piping and electrical raceway supports. The method permits simplified qualification of all connections of frame components through a single load comparison. Test input consists of rotation/cycles-to-failure data and monotonic moment/rotation data. Cyclic data are statistically evaluated to determine an acceptable maximum seismic rotation for the connection. The allowable seismic load is determined from the corresponding static rotation. Application to seismic qualification procedures is discussed. (authors)

  2. A study on the optimal hydraulic loading rate and plant ratios in recirculation aquaponic system.

    Science.gov (United States)

    Endut, Azizah; Jusoh, A; Ali, N; Wan Nik, W B; Hassan, A

    2010-03-01

    The growths of the African catfish (Clarias gariepinus) and water spinach (Ipomoea aquatica) were evaluated in recirculation aquaponic system (RAS). Fish production performance, plant growth and nutrient removal were measured and their dependence on hydraulic loading rate (HLR) was assessed. Fish production did not differ significantly between hydraulic loading rates. In contrast to the fish production, the water spinach yield was significantly higher in the lower hydraulic loading rate. Fish production, plant growth and percentage nutrient removal were highest at hydraulic loading rate of 1.28 m/day. The ratio of fish to plant production has been calculated to balance nutrient generation from fish with nutrient removal by plants and the optimum ratio was 15-42 gram of fish feed/m(2) of plant growing area. Each unit in RAS was evaluated in terms of oxygen demand. Using specified feeding regime, mass balance equations were applied to quantify the waste discharges from rearing tanks and treatment units. The waste discharged was found to be strongly dependent on hydraulic loading rate. 2009 Elsevier Ltd. All rights reserved.

  3. Is earthquake rate in south Iceland modified by seasonal loading?

    Science.gov (United States)

    Jonsson, S.; Aoki, Y.; Drouin, V.

    2017-12-01

    Several temporarily varying processes have the potential of modifying the rate of earthquakes in the south Iceland seismic zone, one of the two most active seismic zones in Iceland. These include solid earth tides, seasonal meteorological effects and influence from passing weather systems, and variations in snow and glacier loads. In this study we investigate the influence these processes may have on crustal stresses and stressing rates in the seismic zone and assess whether they appear to be influencing the earthquake rate. While historical earthquakes in the south Iceland have preferentially occurred in early summer, this tendency is less clear for small earthquakes. The local earthquake catalogue (going back to 1991, magnitude of completeness M6+ earthquakes, which occurred in June 2000 and May 2008. Standard Reasenberg earthquake declustering or more involved model independent stochastic declustering algorithms are not capable of fully eliminating the aftershocks from the catalogue. We therefore inspected the catalogue for the time period before 2000 and it shows limited seasonal tendency in earthquake occurrence. Our preliminary results show no clear correlation between earthquake rates and short-term stressing variations induced from solid earth tides or passing storms. Seasonal meteorological effects also appear to be too small to influence the earthquake activity. Snow and glacier load variations induce significant vertical motions in the area with peak loading occurring in Spring (April-May) and maximum unloading in Fall (Sept.-Oct.). Early summer occurrence of historical earthquakes therefore correlates with early unloading rather than with the peak unloading or unloading rate, which appears to indicate limited influence of this seasonal process on the earthquake activity.

  4. Research on Acoustic Emission and Electromagnetic Emission Characteristics of Rock Fragmentation at Different Loading Rates

    Directory of Open Access Journals (Sweden)

    Fujun Zhao

    2018-01-01

    Full Text Available The relationships among the generation of acoustic emission, electromagnetic emission, and the fracture stress of rock grain are investigated, which are based on the mechanism of acoustic emission and electromagnetic emission produced in the process of indenting rock. Based on the relationships, the influence of loading rate on the characteristics of acoustic emission and electromagnetic emission of rock fragmentation is further discussed. Experiment on rock braking was carried out with three loading rates of 0.001 mm/s, 0.01 mm/s, and 0.1 mm/s. The results show that the phenomenon of acoustic emission and electromagnetic emission is produced during the process of loading and breaking rock. The wave forms of the two signals and the curve of the cutter indenting load show jumping characteristics. Both curves have good agreement with each other. With the increase of loading rate, the acoustic emission and electromagnetic emission signals are enhanced. Through analysis, it is found that the peak count rate, the energy rate of acoustic emission, the peak intensity, the number of pulses of the electromagnetic emission, and the loading rate have a positive correlation with each other. The experimental results agree with the theoretical analysis. The proposed studies can lead to an in-depth understanding of the rock fragmentation mechanism and help to prevent rock dynamic disasters.

  5. Rate of Loaded Sediments in Honda Bay, Puerto Princesa City, Palawan, Philippines

    Directory of Open Access Journals (Sweden)

    Joel Becira

    2006-06-01

    Full Text Available A study in Honda Bay, Puerto Princesa City, Palawan, Philippines was conducted to determine and compare the rate of loaded sediments of and among six sites in Honda Bay and during two seasons, and to discuss sedimentation rate in relation to selected environmental parameters commencing on April 2003 to November 2003.Results showed that the Babuyan River significantly contributed to the amounts of sediments being loaded to Honda Bay, Puerto Princesa City of which the amount of sediments loaded between the two sampling season and among the six sampling events had no significant difference. Sediment's color and texture affirmed the land-based activities in Babuyan and Mauyon watersheds, which eventually carried into the Bay during storm weather condition.The amount of trapped sediments in all stations is probably affected by the river's discharge capacity and the river's water velocity, although the duration sediment traps were mounted could also affect the measurement of sedimentation rate.

  6. Aging and loading rate effects on the mechanical behavior of equine bone

    Science.gov (United States)

    Kulin, Robb M.; Jiang, Fengchun; Vecchio, Kenneth S.

    2008-06-01

    Whether due to a sporting accident, high-speed impact, fall, or other catastrophic event, the majority of clinical bone fractures occur under dynamic loading conditions. However, although extensive research has been performed on the quasi-static fracture and mechanical behavior of bone to date, few high-quality studies on the fracture behavior of bone at high strain rates have been performed. Therefore, many questions remain regarding the material behavior, including not only the loading-rate-dependent response of bone, but also how this response varies with age. In this study, tests were performed on equine femoral bone taken post-mortem from donors 6 months to 28 years of age. Quasi-static and dynamic tests were performed to determine the fracture toughness and compressive mechanical behavior as a function of age at varying loading rates. Fracture paths were then analyzed using scanning confocal and scanning-electron microscopy techniques to assess the role of various microstructural features on toughening mechanisms.

  7. An improved model for considering strain rate effects on reinforced concrete elements behavior under dynamic loads

    International Nuclear Information System (INIS)

    Sim, J.; Soroushian, P.

    1989-01-01

    An improved model for predicting the reinforced concrete element behavior under dynamic strain rates was developed using the layer modeling technique. The developed strain rate sensitive model for axial/flexural analysis of reinforced concrete elements was used to predict the test results, performed at different loading rates, and the predictions were reasonable. The developed analysis technique was used to study the loading rate sensitivity of reinforced concrete beams and columns with different geometry and material properties. Two design formulas for computing the loading rate dependent axial and flexural strengths of reinforced concrete sections are suggested

  8. Mental load, heart rate and heart rate variability.

    NARCIS (Netherlands)

    Blitz, P.S.; Hoogstraten, J.; Mulder, G.

    1970-01-01

    "Several investigators have shown that diminished sinus arrhythmia can be seen as an indication of increased mental load. The present experiment deals with the influence of different levels of mental load, operationalized as the number of binary choices per minute, on the regularity of the heart

  9. EFFECT OF SULFATE LOADING RATE AND ORGANIC LOADING RATE ON ANAEROBIC BAFFLED REACTORS USED FOR TREATMENT OF SANITARY LANDFILL LEACHATES

    Directory of Open Access Journals (Sweden)

    O. Burbano-Figueroa

    2015-06-01

    Full Text Available AbstractThis study investigated the effect of organic loading rate (OLR and sulfate loading rate (SLR on landfill leachate treatment by a lab-scale anaerobic baffled reactor (ABR. Landfill leachate contained a concentration of organic matter between 3966 and 5090 mg COD.L-1 and no detectable amounts of sulfate. Reactors were started-up by feeding them with iron-sulfate at a SLR of 0.05 g SO42-.L-1.day-1 (4 weeks. Factorial design and response surface techniques were used to evaluate and optimize the effects of these operating variables on COD removal. ABRs were operated at OLRs ranging from 0.30 up to 6.84 g COD.L-1.day-1 by changes in influent volumetric flow. SO42- was added to the influent at a SRL from 0.06 to 0.13 g SO42-.L-1.day-1. The highest value of COD removal (66% was reached at an OLR of 3.58 g COD.L-1.day-1 and SLR of 0.09 g SO4-2.L-1.day-1 with a COD/SO4-2 ratio of 40. Under these conditions sulfate is mainly used for molecular hydrogen consumption while organic matter is preferentially degraded via methanogesis.

  10. Effects of Load and Speed on Wear Rate of Abrasive Wear for 2014 Al Alloy

    Science.gov (United States)

    Odabas, D.

    2018-01-01

    In this paper, the effects of the normal load and sliding speed on wear rate of two-body abrasive wear for 2014 Al Alloy were investigated in detail. In order to understand the variation in wear behaviour with load and speed, wear tests were carried out at a sliding distance of 11 m, a speed of 0.36 m/s, a duration of 30 s and loads in the range 3-11 N using 220 grit abrasive paper, and at a speed range 0.09-0.90 m/s, a load of 5 N and an average sliding distance of 11 m using abrasive papers of 150 grit size under dry friction conditions. Before the wear tests, solution treatment of the 2014 Al alloy was carried out at temperatures of 505 and 520 °C for 1 h in a muffle furnace and then quenched in cold water at 15 °C. Later, the ageing treatment was carried out at 185 °C for 8 h in the furnace. Generally, wear rate due to time increased linearly and linear wear resistance decreased with increasing loads. However, the wear rate was directly proportional to the load up to a critical load of 7 N. After this load, the slope of the curves decreased because the excessive deformation of the worn surface and the instability of the abrasive grains began to increase. When the load on an abrasive grain reaches a critical value, the groove width is about 0.17 of the abrasive grain diameter, and the abrasive grains begin to fail. The wear rate due to time increased slightly as the sliding speed increased in the range 0.09-0.90 m/s. The reason for this is that changes arising from strain rate and friction heating are expected with increasing sliding speeds.

  11. Effect of loading rate variation on soybean protein wastewater treatment by UASB reactor

    Science.gov (United States)

    Sun, Yi; Li, Yongfeng; Guo, Zi-rui; Jiao, An-ying; Han, Wei; Yang, Chuan-ping

    2010-11-01

    In order to improve the efficiency and evaluate the feasibility of anaerobic digestion for treatment of soybean protein wastewater. The stability and performance of the Up-Flow Anaerobic Sludge Blanket (UASB) process was investigated at different organic loading rates (OLRS) and hydraulic retention times over 200 days. When chemical oxygen demand (COD) reached maximum, the loading rate was adjusted in a small way and indicators such as VFA, pH and COD in effluent as well as gas production are observed. These experimental results clearly showed that, the most proper corresponding organic loading rate (OLR) and hydraulic retention time were 6 kg/ (m3ṡd) (COD = 6000 mg/L) and 24 h respectively. Up to 85% of COD was removed and the CH4 production rate of 3.2 m3/(m3ṡd) was obtained. The produced biogas contained 72% of CH4. In the mean time, anaerobic sludge multiplies more faster and exiguous particles appeared. Granules with diameter 1-3 mm.

  12. Impact of hydraulic and carbon loading rates of constructed wetlands on contaminants of emerging concern (CECs) removal

    International Nuclear Information System (INIS)

    Sharif, Fariya; Westerhoff, Paul; Herckes, Pierre

    2014-01-01

    Constructed wetlands remove trace organic contaminants via synergistic processes involving plant biomass that include hydrolysis, volatilization, sorption, biodegradation, and photolysis. Wetland design conditions, such as hydraulic loading rates (HLRs) and carbon loading rates (CLRs), influence these processes. Contaminant of emerging concern (CEC) removal by wetland plants was investigated at varying HLRs and CLRs. Rate constants and parameters obtained from batch-scale studies were used in a mechanistic model to evaluate the effect of these two loading rates on CEC removal. CLR significantly influenced CEC removal when wetlands were operated at HLR >5 cm/d. High values of CLR increased removal of estradiol and carbamazepine but lowered that of testosterone and atrazine. Without increasing the cumulative HLR, operating two wetlands in series with varying CLRs could be a way to improve CEC removal. -- Highlights: • A fate-predictive model was developed to evaluate the effect of loading rates on CEC removal in constructed wetlands. • Carbon loading rates (CLRs) can influence CEC removal when wetlands are operated at higher hydraulic loading rates (HLRs). • The effect of CLRs varies among CECs with different physico-chemical properties. • Combination of wetlands with different CLRs can optimize CEC removal without changing the net HLR. -- This article evaluates the effect of design loading rates on contaminant of emerging concern (CEC) removal in constructed wetlands

  13. Textured insoles reduce vertical loading rate and increase subjective plantar sensation in overground running.

    Science.gov (United States)

    Wilkinson, Michael; Ewen, Alistair; Caplan, Nicholas; O'leary, David; Smith, Neil; Stoneham, Richard; Saxby, Lee

    2018-05-01

    The effect of textured insoles on kinetics and kinematics of overground running was assessed. 16 male injury-free-recreational runners attended a single visit (age 23 ± 5 yrs; stature 1.78 ± 0.06 m; mass 72.6 ± 9.2 kg). Overground 15-m runs were completed in flat, canvas plimsolls both with and without textured insoles at self-selected velocity on an indoor track in an order that was balanced among participants. Average vertical loading rate and peak vertical force (F peak ) were captured by force platforms. Video footage was digitised for sagittal plane hip, knee and ankle angles at foot strike and mid stance. Velocity, stride rate and length and contact and flight time were determined. Subjectively rated plantar sensation was recorded by visual scale. 95% confidence intervals estimated mean differences. Smallest worthwhile change in loading rate was defined as standardised reduction of 0.54 from a previous comparison of injured versus non-injured runners. Loading rate decreased (-25 to -9.3 BW s -1 ; 60% likely beneficial reduction) and plantar sensation was increased (46-58 mm) with the insole. F peak (-0.1 to 0.14 BW) and velocity (-0.02 to 0.06 m s -1 ) were similar. Stride length, flight and contact time were lower (-0.13 to -0.01 m; -0.02 to-0.01 s; -0.016 to -0.006 s) and stride rate was higher (0.01-0.07 steps s -1 ) with insoles. Textured insoles elicited an acute, meaningful decrease in vertical loading rate in short distance, overground running and were associated with subjectively increased plantar sensation. Reduced vertical loading rate could be explained by altered stride characteristics.

  14. Two Coupled Queues with Vastly Different Arrival Rates: Critical Loading Case

    Directory of Open Access Journals (Sweden)

    Charles Knessl

    2011-01-01

    Full Text Available We consider two coupled queues with a generalized processor sharing service discipline. The second queue has a much smaller Poisson arrival rate than the first queue, while the customer service times are of comparable magnitude. The processor sharing server devotes most of its resources to the first queue, except when it is empty. The fraction of resources devoted to the second queue is small, of the same order as the ratio of the arrival rates. We assume that the primary queue is heavily loaded and that the secondary queue is critically loaded. If we let the small arrival rate to the secondary queue be O(ε, where 0≤ε≪1, then in this asymptotic limit the number of customers in the first queue will be large, of order O(ε-1, while that in the second queue will be somewhat smaller, of order O(ε-1/2. We obtain a two-dimensional diffusion approximation for this model and explicitly solve for the joint steady state probability distribution of the numbers of customers in the two queues. This work complements that in (Morrison, 2010, which the second queue was assumed to be heavily or lightly loaded, leading to mean queue lengths that were O(ε-1 or O(1, respectively.

  15. Running quietly reduces ground reaction force and vertical loading rate and alters foot strike technique.

    Science.gov (United States)

    Phan, Xuan; Grisbrook, Tiffany L; Wernli, Kevin; Stearne, Sarah M; Davey, Paul; Ng, Leo

    2017-08-01

    This study aimed to determine if a quantifiable relationship exists between the peak sound amplitude and peak vertical ground reaction force (vGRF) and vertical loading rate during running. It also investigated whether differences in peak sound amplitude, contact time, lower limb kinematics, kinetics and foot strike technique existed when participants were verbally instructed to run quietly compared to their normal running. A total of 26 males completed running trials for two sound conditions: normal running and quiet running. Simple linear regressions revealed no significant relationships between impact sound and peak vGRF in the normal and quiet conditions and vertical loading rate in the normal condition. t-Tests revealed significant within-subject decreases in peak sound, peak vGRF and vertical loading rate during the quiet compared to the normal running condition. During the normal running condition, 15.4% of participants utilised a non-rearfoot strike technique compared to 76.9% in the quiet condition, which was corroborated by an increased ankle plantarflexion angle at initial contact. This study demonstrated that quieter impact sound is not directly associated with a lower peak vGRF or vertical loading rate. However, given the instructions to run quietly, participants effectively reduced peak impact sound, peak vGRF and vertical loading rate.

  16. Load and resistance factor rating (LRFR) in New York State : volume II.

    Science.gov (United States)

    2011-09-01

    This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...

  17. Load and resistance factor rating (LRFR) in New York State : volume I.

    Science.gov (United States)

    2011-09-01

    This report develops a Load and Resistance Factor Rating (NYS-LRFR) methodology : for New York bridges. The methodology is applicable for the rating of existing : bridges, the posting of under-strength bridges, and checking Permit trucks. The : propo...

  18. A quantitative approach to the loading rate of seismogenic sources in Italy

    Science.gov (United States)

    Caporali, Alessandro; Braitenberg, Carla; Montone, Paola; Rossi, Giuliana; Valensise, Gianluca; Viganò, Alfio; Zurutuza, Joaquin

    2018-03-01

    To investigate the transfer of elastic energy between a regional stress field and a set of localized faults we project the stress rate tensor inferred from the Italian GNSS velocity field onto faults selected from the Database of Individual Seismogenic Sources (DISS 3.2.0). For given Lamé constants and friction coefficient we compute the loading rate on each fault in terms of the Coulomb Failure Function (CFF) rate. By varying the strike, dip and rake angles around the nominal DISS values, we also estimate the geometry of planes that are optimally oriented for maximal CFF rate. Out of 86 Individual Seismogenic Sources (ISSs), all well covered by GNSS data, 78 to 81 (depending on the assumed friction coefficient) load energy at a rate of 0-4 kPa/yr. The faults displaying larger CFF rates (4 to 6 ± 1 kPa/yr) are located in the central Apennines and are all characterized by a significant strike-slip component. We also find that the loading rate of 75 per cent of the examined sources is less than 1 kPa/yr lower than that of optimally oriented faults. We also analyzed the 24 August and 30 October 2016, central Apennines earthquakes (Mw 6.0-6.5 respectively). The strike of their causative faults based on seismological and tectonic data and the geodetically inferred strike differ by < 30°. Some sources exhibit a strike oblique to the direction of maximum strain rate, suggesting that in some instances the present-day stress acts on inherited faults. The choice of the friction coefficient only marginally affects this result.

  19. A quantitative approach to the loading rate of seismogenic sources in Italy

    Science.gov (United States)

    Caporali, Alessandro; Braitenberg, Carla; Montone, Paola; Rossi, Giuliana; Valensise, Gianluca; Viganò, Alfio; Zurutuza, Joaquin

    2018-06-01

    To investigate the transfer of elastic energy between a regional stress field and a set of localized faults, we project the stress rate tensor inferred from the Italian GNSS (Global Navigation Satellite Systems) velocity field onto faults selected from the Database of Individual Seismogenic Sources (DISS 3.2.0). For given Lamé constants and friction coefficient, we compute the loading rate on each fault in terms of the Coulomb failure function (CFF) rate. By varying the strike, dip and rake angles around the nominal DISS values, we also estimate the geometry of planes that are optimally oriented for maximal CFF rate. Out of 86 Individual Seismogenic Sources (ISSs), all well covered by GNSS data, 78-81 (depending on the assumed friction coefficient) load energy at a rate of 0-4 kPa yr-1. The faults displaying larger CFF rates (4-6 ± 1 kPa yr-1) are located in the central Apennines and are all characterized by a significant strike-slip component. We also find that the loading rate of 75% of the examined sources is less than 1 kPa yr-1 lower than that of optimally oriented faults. We also analysed 2016 August 24 and October 30 central Apennines earthquakes (Mw 6.0-6.5, respectively). The strike of their causative faults based on seismological and tectonic data and the geodetically inferred strike differ by <30°. Some sources exhibit a strike oblique to the direction of maximum strain rate, suggesting that in some instances the present-day stress acts on inherited faults. The choice of the friction coefficient only marginally affects this result.

  20. Probabilistic concept to describe the influence of rate of loading on strength of concrete

    International Nuclear Information System (INIS)

    Mihashi, H.; Wittmann, F.H.

    1981-01-01

    Any reliability assessment of concrete structures is dependent on realistic assumptions on strength distribution. By means of experimental test series the most appropriate distribution function cannot be determined. In this contribution a theoretical concept to describe variability of strength of concrete will be presented. This approach is based on the characteristic composite structure. The structure of concrete is composed of aggregates and a binding agent i.e. porous hardened cement paste. Under formal conditions there are already big pores and cracks in the matrix as well as in the interface before a specimen is loaded. All structural defects can be assumed to be statistically distributed all over the specimen. If a load is applied cracks start to grow form the most critical structural defects. For a realistic estimation of the reliability of a secondary containment under impact loading conditions the influence of rate of loading on mean value and variability of strength is of major interest. The presented theory predicts that the mean strength increases with a power law as the rate of loading increases, while the coefficient of variation remains constant. A number of test series have been carried out to verify the theoretical concept. Different types of mortar (model concrete) and concrete have been included in the test program. Within the range of accuracy experimental results agree well with theoretical predictions. It can be concluded that the variability of macroscopic properties of concrete can be linked with the distribution of structural defects. Strength of concrete is best represented by a Weibull-type distribution function. The influence of rate of loading on strength can be experessed by means of a general rate process. (orig.)

  1. Motor operated valve testing and the 'rate of loading' phenomenon

    International Nuclear Information System (INIS)

    Black, B.R.

    1991-01-01

    This paper discusses valve design features which affect the ability to predict motor operated valve (MOV) performance and reviews factors which should be considered when selecting switch settings to limit stem loads. Considerable attention is given to the rate of loading phenomenon which affects the relationship between valve stem thrust and actuator spring pack deflection. Equations are developed, and testing is discussed which permit the construction of an MOV dynamic model. Factors which must be considered when maintaining switch settings correct throughout the life of the plant are discussed. And switch setting acceptance criteria for use with baseline Static and Design Basis testing are suggested

  2. Effect of the loading rate on compressive properties of goose eggs.

    Science.gov (United States)

    Nedomová, Š; Kumbár, V; Trnka, J; Buchar, J

    2016-03-01

    The resistance of goose (Anser anser f. domestica) eggs to damage was determined by measuring the average rupture force, specific deformation and rupture energy during their compression at different compression speeds (0.0167, 0.167, 0.334, 1.67, 6.68 and 13.36 mm/s). Eggs have been loaded between their poles (along X axis) and in the equator plane (Z axis). The greatest amount of force required to break the eggs was required when eggs were loaded along the X axis and the least compression force was required along the Z axis. This effect of the loading orientation can be described in terms of the eggshell contour curvature. The rate sensitivity of the eggshell rupture force is higher than that observed for the Japanese quail's eggs.

  3. Loading rate and test temperature effects on fracture of in situ niobium silicide-niobium composites

    International Nuclear Information System (INIS)

    Rigney, J.D.; Lewandowski, J.J.

    1996-01-01

    Arc cast, extruded, and heat-treated in situ composites of niobium silicide (Nb 5 Si 3 ) intermetallic with niobium phases (primary--Nb p and secondary--Nb s ) exhibited high fracture resistance in comparison to monolithic Nb 5 Si 3 . In toughness tests conducted at 298 K and slow applied loading rates, the fracture process proceeded by the microcracking of the Nb 5 Si 3 and plastic deformation of the Nb p and Nb s phases, producing resistance-curve behavior and toughnesses of 28 MPa√m with damage zone lengths less than 500 microm. The effects of changes in the Nb p yield strength and fracture behavior on the measured toughnesses were investigated by varying the loading rates during fracture tests at both 77 and 298 K. Quantitative fractography was utilized to completely characterize each fracture surface created at 298 K in order to determine the type of fracture mode (i.e., dimpled, cleavage) exhibited by the Nb p . Specimens tested at either higher loading rates or lower test temperatures consistently exhibited a greater amount of cleavage fracture in the Nb p , while the Nb s always remained ductile. However, the fracture toughness values determined from experiments spanning six orders of magnitude in loading rate at 298 and 77 K exhibited little variation, even under conditions when the majority of Nb p phases failed by cleavage at 77 K. The changes in fracture mode with increasing loading rate and/or decreasing test temperature and their effects on fracture toughness are rationalized by comparison to existing theoretical models

  4. Strain-rate effect on initial crush stress of irregular honeycomb under dynamic loading and its deformation mechanism

    Science.gov (United States)

    Wang, Peng; Zheng, Zhijun; Liao, Shenfei; Yu, Jilin

    2018-02-01

    The seemingly contradictory understandings of the initial crush stress of cellular materials under dynamic loadings exist in the literature, and a comprehensive analysis of this issue is carried out with using direct information of local stress and strain. Local stress/strain calculation methods are applied to determine the initial crush stresses and the strain rates at initial crush from a cell-based finite element model of irregular honeycomb under dynamic loadings. The initial crush stress under constant-velocity compression is identical to the quasi-static one, but less than the one under direct impact, i.e. the initial crush stresses under different dynamic loadings could be very different even though there is no strain-rate effect of matrix material. A power-law relation between the initial crush stress and the strain rate is explored to describe the strain-rate effect on the initial crush stress of irregular honeycomb when the local strain rate exceeds a critical value, below which there is no strain-rate effect of irregular honeycomb. Deformation mechanisms of the initial crush behavior under dynamic loadings are also explored. The deformation modes of the initial crush region in the front of plastic compaction wave are different under different dynamic loadings.

  5. Integrated load distribution and production planning in series-parallel multi-state systems with failure rate depending on load

    International Nuclear Information System (INIS)

    Nourelfath, Mustapha; Yalaoui, Farouk

    2012-01-01

    A production system containing a set of machines (also called components) arranged according to a series-parallel configuration is addressed. A set of products must be produced in lots on this production system during a specified finite planning horizon. This paper presents a method for integrating load distribution decisions, and tactical production planning considering the costs of capacity change and the costs of unused capacity. The objective is to minimize the sum of capacity change costs, unused capacity costs, setup costs, holding costs, backorder costs, and production costs. The main constraints consist in satisfying the demand for all products over the entire horizon, and in not exceeding available repair resource. The production series-parallel system is modeled as a multi-state system with binary-state components. The proposed model takes into account the dependence of machines' failure rates on their load. Universal generating function technique can be used in the optimization algorithm for evaluating the expected system production rate in each period. We show how the formulated problem can be solved by comparing the results of several multi-product lot-sizing problems with capacity associated costs. The importance of integrating load distribution decisions and production planning is illustrated through numerical examples.

  6. An attempt to explain strength increase due to high loading rates

    International Nuclear Information System (INIS)

    Eibl, J.; Curbach, M.

    1989-01-01

    Most materials such as steel, concrete, ceramics, polymers, etc. show an increase of strength due to high loading rates. A number of mathematical equations are available to describe this behaviour. Nevertheless the physical reasons for these observations are still unknown. The common behaviour of a number of materials leads to the assumption that at least some explanations are material independent. Due to this reason the results of the research done at the Institute for Concrete Structures in Karlsruhe are presented in this paper to furnish new ideas for the material research due to dynamic loading. (orig.)

  7. Strain rate dependency of bovine trabecular bone under impact loading at sideways fall velocity.

    Science.gov (United States)

    Enns-Bray, William S; Ferguson, Stephen J; Helgason, Benedikt

    2018-05-03

    There is currently a knowledge gap in scientific literature concerning the strain rate dependent properties of trabecular bone at intermediate strain rates. Meanwhile, strain rates between 10 and 200/s have been observed in previous dynamic finite element models of the proximal femur loaded at realistic sideways fall speeds. This study aimed to quantify the effect of strain rate (ε̇) on modulus of elasticity (E), ultimate stress (σ u ), failure energy (U f ), and minimum stress (σ m ) of trabecular bone in order to improve the biofidelity of material properties used in dynamic simulations of sideways fall loading on the hip. Cylindrical cores of trabecular bone (D = 8 mm, L gauge  = 16 mm, n = 34) from bovine proximal tibiae and distal femurs were scanned in µCT (10 µm), quantifying apparent density (ρ app ) and degree of anisotropy (DA), and subsequently impacted within a miniature drop tower. Force of impact was measured using a piezoelectric load cell (400 kHz), while displacement during compression was measured from high speed video (50,000 frames/s). Four groups, with similar density distributions, were loaded at different impact velocities (0.84, 1.33, 1.75, and 2.16 m/s) with constant kinetic energy (0.4 J) by adjusting the impact mass. The mean strain rates of each group were significantly different (p < 0.05) except for the two fastest impact speeds (p = 0.09). Non-linear regression models correlated strain rate, DA, and ρ app with ultimate stress (R 2  = 0.76), elastic modulus (R 2  = 0.63), failure energy (R 2  = 0.38), and minimum stress (R 2  = 0.57). These results indicate that previous estimates of σ u could be under predicting the mechanical properties at strain rates above 10/s. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Rate-dependent response of superelastic Cu–Al–Mn alloy rods to tensile cyclic loads

    International Nuclear Information System (INIS)

    Araki, Yoshikazu; Maekawa, Nao; Omori, Toshihiro; Sutou, Yuji; Kainuma, Ryosuke; Ishida, Kiyohito

    2012-01-01

    We report the results of tensile cyclic loading tests conducted to examine the dependence of constitutive relations for superelastic Cu–Al–Mn alloy rods on loading rates. Recently, Cu–Al–Mn alloy rods with diameters up to 8 mm have been developed by the authors, and it has been demonstrated that these rods have excellent superelastic strains of more than 8%, which is comparable to Ni–Ti alloys and far superior to other Cu-based alloys. No information is available, however, on the rate dependence of constitutive relations for Cu–Al–Mn alloys. In this study, we prepare two Cu–Al–Mn alloy rod specimens, whose lengths and diameters are 150 mm and 8 mm, respectively. Their stress–strain relations are examined under the loading frequencies of 0.001, 0.5, and 1 Hz with constant strain amplitude of 4.5%. It was found from the tests that the maximum stress increase in Cu–Al–Mn alloys due to higher loading rate was less than 5%. Thermo-mechanical analysis predicts that stress increase in Cu–Al–Mn alloys is about 1/4 of that in Ni–Ti alloys, which agrees reasonably well with the experimental observations. Such low stress increase is highly desirable in the design of seismic devices such as dampers and isolators. (fast track communication)

  9. Predicting fractional bed load transport rates: Application of the Wilcock‐Crowe equations to a regulated gravel bed river

    Science.gov (United States)

    Gaeuman, David; Andrews, E.D.; Krause, Andreas; Smith, Wes

    2009-01-01

    Bed load samples from four locations in the Trinity River of northern California are analyzed to evaluate the performance of the Wilcock‐Crowe bed load transport equations for predicting fractional bed load transport rates. Bed surface particles become smaller and the fraction of sand on the bed increases with distance downstream from Lewiston Dam. The dimensionless reference shear stress for the mean bed particle size (τ*rm) is largest near the dam, but varies relatively little between the more downstream locations. The relation between τ*rm and the reference shear stresses for other size fractions is constant across all locations. Total bed load transport rates predicted with the Wilcock‐Crowe equations are within a factor of 2 of sampled transport rates for 68% of all samples. The Wilcock‐Crowe equations nonetheless consistently under‐predict the transport of particles larger than 128 mm, frequently by more than an order of magnitude. Accurate prediction of the transport rates of the largest particles is important for models in which the evolution of the surface grain size distribution determines subsequent bed load transport rates. Values of τ*rm estimated from bed load samples are up to 50% larger than those predicted with the Wilcock‐Crowe equations, and sampled bed load transport approximates equal mobility across a wider range of grain sizes than is implied by the equations. Modifications to the Wilcock‐Crowe equation for determining τ*rm and the hiding function used to scale τ*rm to other grain size fractions are proposed to achieve the best fit to observed bed load transport in the Trinity River.

  10. Nitrogen removal in permeable woodchips filters affected by hydraulic loading rate and woodchips ratio

    DEFF Research Database (Denmark)

    Bruun, Jacob Druedahl; Kjærgaard, Charlotte; Hoffmann, Carl Christian

    2016-01-01

    response of mixed reactive media (woodchips-Seashells and woodchips-Filtralite mixtures) at two woodchips ratios (WR) to changes in the hydraulic loading rate (HLR). The tests implied continuous loading of aerated NO3-N spiked artificial drainage water and tritium (3H2O) breakthrough experiments. Flow...... normalized nitrate reduction rates were 0.35-3.97 g N m-3 L-1, corresponding to N- removal efficiencies of 5 to 74% depending on HLR and filter mixtures. At high HLR oxic conditions prevailed, thus N removal was restricted to the immobile domain, controlled by diffusion. At lower HLR, progressively lower...

  11. Rate-independent dissipation and loading direction effects in compressed carbon nanotube arrays

    International Nuclear Information System (INIS)

    Raney, J R; Fraternali, F; Daraio, C

    2013-01-01

    Arrays of nominally-aligned carbon nanotubes (CNTs) under compression deform locally via buckling, exhibit a foam-like, dissipative response, and can often recover most of their original height. We synthesize millimeter-scale CNT arrays and report the results of compression experiments at different strain rates, from 10 −4 to 10 −1 s −1 , and for multiple compressive cycles to different strains. We observe that the stress–strain response proceeds independently of the strain rate for all tests, but that it is highly dependent on loading history. Additionally, we examine the effect of loading direction on the mechanical response of the system. The mechanical behavior is modeled using a multiscale series of bistable springs. This model captures the rate independence of the constitutive response, the local deformation, and the history-dependent effects. We develop here a macroscopic formulation of the model to represent a continuum limit of the mesoscale elements developed previously. Utilizing the model and our experimental observations we discuss various possible physical mechanisms contributing to the system’s dissipative response. (paper)

  12. Relationship Between Pretraining Subjective Wellness Measures, Player Load, and Rating-of-Perceived-Exertion Training Load in American College Football.

    Science.gov (United States)

    Govus, Andrew D; Coutts, Aaron; Duffield, Rob; Murray, Andrew; Fullagar, Hugh

    2018-01-01

    The relationship between pretraining subjective wellness and external and internal training load in American college football is unclear. To examine the relationship of pretraining subjective wellness (sleep quality, muscle soreness, energy, wellness Z score) with player load and session rating of perceived exertion (s-RPE-TL) in American college football players. Subjective wellness (measured using 5-point, Likert-scale questionnaires), external load (derived from GPS and accelerometry), and s-RPE-TL were collected during 3 typical training sessions per week for the second half of an American college football season (8 wk). The relationship of pretraining subjective wellness with player load and s-RPE training load was analyzed using linear mixed models with a random intercept for athlete and a random slope for training session. Standardized mean differences (SMDs) denote the effect magnitude. A 1-unit increase in wellness Z score and energy was associated with trivial 2.3% (90% confidence interval [CI] 0.5, 4.2; SMD 0.12) and 2.6% (90% CI 0.1, 5.2; SMD 0.13) increases in player load, respectively. A 1-unit increase in muscle soreness (players felt less sore) corresponded to a trivial 4.4% (90% CI -8.4, -0.3; SMD -0.05) decrease in s-RPE training load. Measuring pretraining subjective wellness may provide information about players' capacity to perform in a training session and could be a key determinant of their response to the imposed training demands American college football. Hence, monitoring subjective wellness may aid in the individualization of training prescription in American college football players.

  13. Load rate dependence of the mechanical properties of thermal barrier coating systems

    Energy Technology Data Exchange (ETDEWEB)

    Zotov, Nikolay; Eggeler, Gunther [Institut fuer Werkstoffe, Ruhr Universitaet Bochum, 44780 Bochum (Germany); Bartsch, Marion [Institut fuer Werkstoff-Forschung, DLR Koeln, 51147 Koeln (Germany)

    2009-07-01

    Thermal barrier coatings (TBC), composed of yttrium-stabilized zirconia (YSZ) ceramic top coat (TC) and intermetallic NiCoCrAlY bond coat (BC) are commonly used as protective coatings of Ni-based high temperature gas engine components. Nanoindentation techniques are increasingly applied for determining the TBC mechanical properties on a nanometre scale. However, little is known about the load-rate dependence of the mechanical properties, which is important for better understanding of cyclic thermal fatigue experiments. Nanoindentations with different load rates omega were performed on polished cross-sections of TBC, deposited by EB-PVD on IN625 substrates (S), using a XP Nanoindenter (MTS) equipped with Berkovich diamond tip. The Young's modulus (E) of the TC is independent of omega, while E for the BC and the S decreases with omega. The hardness (H) of the TC and the BC increases, while H for the S decreases with omega. From the dependence of H on omega, creep power-law exponents c = 0.24(11) and c = 0.023(6) for the TC and the BC were determined. For all TBC components, a decrease with omega of the power-law exponents n and m, describing the loading and unloading nanoindentation curves, is observed.

  14. The Influence of the Loading Rate on the Mechanical Properties of Drawing Steel Sheet

    Directory of Open Access Journals (Sweden)

    Buršák, M.

    2006-01-01

    Full Text Available The paper analyzes the influence of the loading rate in the interval from 1 to 1000 mm/min on the mechanical properties of drawing steel sheet H260LAD with the gauge of 1 mm, used for the manufacture of automotive parts, under tension and bending conditions. It describes the aspects of material characteristics under tension and bending conditions, while bending tests were made on notched specimens (a modified impact bending test. The paper presents knowledge that using a modified notch toughness test it is possible to achieve the pressability (formability characteristics corresponding to dynamic strain rates even under the static loading.

  15. An estimation of finger-tapping rates and load capacities and the effects of various factors.

    Science.gov (United States)

    Ekşioğlu, Mahmut; İşeri, Ali

    2015-06-01

    The aim of this study was to estimate the finger-tapping rates and finger load capacities of eight fingers (excluding thumbs) for a healthy adult population and investigate the effects of various factors on tapping rate. Finger-tapping rate, the total number of finger taps per unit of time, can be used as a design parameter of various products and also as a psychomotor test for evaluating patients with neurologic problems. A 1-min tapping task was performed by 148 participants with maximum volitional tempo for each of eight fingers. For each of the tapping tasks, the participant with the corresponding finger tapped the associated key in the standard position on the home row of a conventional keyboard for touch typing. The index and middle fingers were the fastest fingers for both hands, and little fingers the slowest. All dominant-hand fingers, except little finger, had higher tapping rates than the fastest finger of the nondominant hand. Tapping rate decreased with age and smokers tapped faster than nonsmokers. Tapping duration and exercise had also significant effect on tapping rate. Normative data of tapping rates and load capacities of eight fingers were estimated for the adult population. In designs of psychomotor tests that require the use of tapping rate or finger load capacity data, the effects of finger, age, smoking, and tapping duration need to be taken into account. The findings can be used for ergonomic designs requiring finger-tapping capacity and also as a reference in psychomotor tests. © 2015, Human Factors and Ergonomics Society.

  16. Operative correction of judoists’ training loads on the base of on-line monitoring of heart beats rate

    Directory of Open Access Journals (Sweden)

    Yong Qiang Liu

    2015-04-01

    Full Text Available Purpose: ensure increase of effectiveness of training process’s control by means of operative correction of training loads of different qualification judo wrestlers’ heart beats rate indicators. Material: the research was conducted on the base of Brest SCJSOR № 1. Judo wrestlers of different sport qualification (age 17-19 years old, n=15 participated in the research. Monitoring of judo wrestlers’ heart beats rate was carried out with the help of system “Polar”. Results: we have found factorial structure of functional fitness in every profile of sportsmen. Model characteristics of judo wrestlers were supplemented with the most important sides of functional fitness. Analysis of indicators of restoration effectiveness indicators (REI in both groups of judo wrestlers showed high level of organism’s responsiveness to training load of special and power orientation in comparison with speed power load. We have worked out algorithm of operative correction of training loads by indicators of heart beats rate in training process, depending on orientation and intensity of loads’ physiological influence on judo wrestler. Conclusions: Telemetric on-line monitoring of sportsman’s heart beats rate and calculation of REI permit to objectively assess effectiveness of training’s construction and of micro-cycle in total and detect in due time the trend to development of over-loading and failure of adaptation.

  17. Operative correction of judoists’ training loads on the base of on-line monitoring of heart beats rate

    Directory of Open Access Journals (Sweden)

    Liu Yong Qiang

    2015-02-01

    Full Text Available Purpose: ensure increase of effectiveness of training process’s control by means of operative correction of training loads of different qualification judo wrestlers’ heart beats rate indicators. Material: the research was conducted on the base of Brest SCJSOR № 1. Judo wrestlers of different sport qualification (age 17-19 years old, n=15 participated in the research. Monitoring of judo wrestlers’ heart beats rate was carried out with the help of system “Polar”. Results: we have found factorial structure of functional fitness in every profile of sportsmen. Model characteristics of judo wrestlers were supplemented with the most important sides of functional fitness. Analysis of indicators of restoration effectiveness indicators (REI in both groups of judo wrestlers showed high level of organism’s responsiveness to training load of special and power orientation in comparison with speed power load. We have worked out algorithm of operative correction of training loads by indicators of heart beats rate in training process, depending on orientation and intensity of loads’ physiological influence on judo wrestler. Conclusions: Telemetric on-line monitoring of sportsman’s heart beats rate and calculation of REI permit to objectively assess effectiveness of training’s construction and of micro-cycle in total and detect in due time the trend to development of over-loading and failure of adaptation.

  18. Response Load Extrapolation for Wind Turbines during Operation Based on Average Conditional Exceedance Rates

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Naess, Arvid; Saha, Nilanjan

    2011-01-01

    to cases where the Gumbel distribution is the appropriate asymptotic extreme value distribution. However, two extra parameters are introduced by which a more general and flexible class of extreme value distributions is obtained with the Gumbel distribution as a subclass. The general method is implemented...... within a hierarchical model where the variables that influence the loading are divided into ergodic variables and time-invariant non-ergodic variables. The presented method for statistical response load extrapolation was compared with the existing methods based on peak extrapolation for the blade out......The paper explores a recently developed method for statistical response load (load effect) extrapolation for application to extreme response of wind turbines during operation. The extrapolation method is based on average conditional exceedance rates and is in the present implementation restricted...

  19. High Strain Rate Deformation Mechanisms of Body Centered Cubic Material Subjected to Impact Loading

    Science.gov (United States)

    Visser, William

    Low carbon steel is the most common grade of structural steel used; it has carbon content of 0.05% to 0.25% and very low content of alloying elements. It is produced in great quantities and provides material properties that are acceptable for many engineering applications, particularly in the construction industry in which low carbon steel is widely used as the strengthening phase in civil structures. The overall goal of this dissertation was to investigate the deformation response of A572 grade 50 steel when subjected to impact loading. This steel has a 0.23% by weight carbon content and has less than 2% additional alloying elements. The deformation mechanisms of this steel under shock loading conditions include both dislocation motion and twin formation. The goal of this work was achieved by performing experimental, analytical and numerical research in three integrated tasks. The first is to determine the relationship between the evolution of deformation twins and the impact pressure. Secondly, a stress criterion for twin nucleation during high strain rate loading was developed which can account for the strain history or initial dislocation density. Lastly, a method was applied for separating the effects of dislocations and twins generated by shock loading in order to determine their role in controlling the flow stress of the material. In this regard, the contents of this work have been categorically organized. First, the active mechanisms in body centered cubic (BCC) low carbon steel during shock loading have been determined as being a composed of the competing mechanisms of dislocations and deformation twins. This has been determined through a series of shock loading tests of the as-received steel. The shock loading tests were done by plate impact experiments at several impact pressures ranging from 2GPa up to 13GPa using a single stage light gas gun. A relationship between twin volume fraction and impact pressure was determined and an analytical model was

  20. The effect of loading rate on ductile fracture toughness and fracture surface roughness

    DEFF Research Database (Denmark)

    Osovski, S.; Srivastava, Akhilesh Kumar; Ponson, L.

    2015-01-01

    The variation of ductile crack growth resistance and fracture surface roughness with loading rate is modeled under mode I plane strain, small scale yielding conditions. Three-dimensional calculations are carried out using an elastic-viscoplastic constitutive relation for a progressively cavitatin...

  1. A high rate clarifier for load levelling in sewerage systems.

    Science.gov (United States)

    Jago, R A; Davey, A; Li, H

    2003-01-01

    The combining of chemically assisted clarification with a proprietary physical separation technology has led to a high rate process for clarifying flocculated sewage and other waste streams. This hybrid physico-chemical system, known as the CDS Fine Solids Separation (FSS) System, was developed over a two year period within a sewage treatment plant environment. This paper summarises the results of a recent field trial of the system with a Victorian water authority which experiences heavy loading of sewers in a coastal town during holiday periods. The trial sought to evaluate the FSS as a tool for smoothing the load on the 11 km long sewer to the sewage treatment plant (STP). The FSS system could possibly enable the costly augmentation of the sewer to be deferred, particularly as the capacity of the existing sewer pipe is satisfactory for most of the year. Water quality parameters were determined for a range of flowrates and operational conditions over a two month period. Large reductions were achieved in TSS, TP, FC, turbidity and BOD5, with only minimal reductions in NH3 and TON. These results showed that the FSS could meet the authority's objectives for load levelling and would provide a 20-25% increase in effective sewer capacity. The data are also discussed in terms of possible use of the effluent from the FSS for water reuse applications.

  2. A Spike Neural Controller for Traffic Load Parameter with Priority-Based Rate in Wireless Multimedia Sensor Networks

    Directory of Open Access Journals (Sweden)

    Nadia Adnan Shiltagh

    2015-11-01

    Full Text Available Wireless Multimedia Sensor Networks (WMSNs are a type of sensor network that contains sensor nodes equipped with cameras, microphones; therefore the WMSNS are able to produce multimedia data such as video and audio streams, still images, and scalar data from the surrounding environment. Most multimedia applications typically produce huge volumes of data, this leads to congestion. To address this challenge, This paper proposes Modify Spike Neural Network control for Traffic Load Parameter with Exponential Weight of Priority Based Rate Control algorithm (MSNTLP with EWBPRC. The Modify Spike Neural Network controller (MSNC can calculate the appropriate traffic load parameter μ for each parent node and then use in the EWPBRC algorithm to estimate the transmission rate of parent nodes and then assign a suitable transmission rate for each child node. A comparative study between (MSNTLP with EWBPRC and fuzzy logic controller for traffic load parameter with Exponential Weight of Priority Based Rate Control algorithm (FTLP with EWBPRC algorithm shows that the (MSNTLP with EWBPRC is more efficient than (FTLP with EWBPRC algorithm in terms of packet loss, queue delay and throughput. Another comparative study between (MSNTLP with EWBPRC and EWBPRC with fixed traffic load parameter (µ shows that the MSNTLP with EWBPRC is more efficient than EWBPRC with fixed traffic load parameter (µ in terms of packet loss ratio and queue delay. A simulation process is developed and tested using the network simulator _2 (NS2 in a computer having the following properties: windows 7 (64-bit, core i7, RAM 8GB, hard 1TB.

  3. Ammonia and nitrite removal rates in a closed recirculating-water system, under three load rates of rainbow trout Oncorhynchus mykiss

    OpenAIRE

    Arredondo-Figueroa, J. L.; Ingle de la Mora, G; Guerrero-Legarreta, I; Ponce-Palafox, J. T.; Barriga-Sosa, I. de los A.

    2007-01-01

    Nitrification and denitrification rates of inorganic nitrogen were studied in a closed recirculating-water system, comparing three load rates of rainbow trout Oncorhynchus mykiss (89, 156 and 194 kg in each tank with two repetitions). Six self-cleaning water circular fish tanks with a volume of 4.3 m³ were used, maintaining a 3.94 m³/day of average flow rate and constant aeration. A total of 371 rainbow trout, 524 ± 8 g initial wet weight were introduced in the system and fed with a commercia...

  4. THE EFFECTS OF DIFFERENT WORK-LOADING APPLIED TO THE WORKERS THAT WORK PRODUCING OF SHIRT TO THE SEAM FAULT RATES

    Directory of Open Access Journals (Sweden)

    Önder YÜCEL

    2001-03-01

    Full Text Available Human efficiency is of big importance in the clothing industry. So as to provide high quality and productivity stabilized work –loading must be given to the workers that work in the cloth production lines. In addition to it, the kind of work must be paid attention in the studies to be done on stabilized work-loading. The aim of this study is to determine the effects of different work-loading to the seam fault rates. For this purpose, four different work-loading had been applied to the workers and determined seam faults on the clothes had been recorded. As a result of this study, seam fault rates in the different work-loading had been evaluated.

  5. Tensile characterisation of the aorta across quasi-static to blast loading strain rates

    Science.gov (United States)

    Magnus, Danyal; Proud, William; Haller, Antoine; Jouffroy, Apolline

    2017-06-01

    The dynamic tensile failure mechanisms of the aorta during Traumatic Aortic Injury (TAI) are poorly understood. In automotive incidents, where the aorta may be under strains of the order of 100/s, TAI is the second largest cause of mortality. In these studies, the proximal descending aorta is the most common site where rupture is observed. In particular, the transverse direction is most commonly affected due to the circumferential orientation of elastin, and hence the literature generally concentrates upon axial samples. This project extends these dynamic studies to the blast loading regime where strain-rates are of the order of 1000/s. A campaign of uniaxial tensile experiments are conducted at quasi-static, intermediate (drop-weight) and high (tensile Split-Hopkinson Pressure Bar) strain rates. In each case, murine and porcine aorta models are considered and the extent of damage assessed post-loading using histology. Experimental data will be compared against current viscoelastic models of the aorta under axial stress. Their applicability across strain rates will be discussed. Using a multi-disciplinary approach, the conditions applied to the samples replicate in vivo conditions, employing a blood simulant-filled tubular specimen surrounded by a physiological solution.

  6. Handball load and shoulder injury rate: a 31-week cohort study of 679 elite youth handball players.

    Science.gov (United States)

    Møller, M; Nielsen, R O; Attermann, J; Wedderkopp, N; Lind, M; Sørensen, H; Myklebust, G

    2017-02-01

    Knowledge of injury patterns, an essential step towards injury prevention, is lacking in youth handball. To investigate if an increase in handball load is associated with increased shoulder injury rates compared with a minor increase or decrease, and if an association is influenced by scapular control, isometric shoulder strength or glenohumeral range of motion (ROM). 679 players (14-18 years) provided weekly reports on shoulder injury and handball load (training and competition hours) over 31 weeks using the SMS, phone and medical examination system. Handball load in a given week was categorised into (1) 60% relative to the weekly average amount of handball load the preceding 4 weeks. Assessment of shoulder isometric rotational and abduction strength, ROM and scapular control was performed at baseline and midseason. An increase in handball load by >60% was associated with greater shoulder injury rate (HR 1.91; 95% CI 1.00 to 3.70, p=0.05) compared with the reference group. The effect of an increase in handball load between 20% and 60% was exacerbated among players with reduced external rotational strength (HR 4.0; 95% CI 1.1 to 15.2, p=0.04) or scapular dyskinesis (HR 4.8; 95% CI 1.3 to 18.3, p=0.02). Reduced external rotational strength exacerbated the effect of an increase above 60% (HR 4.2; 95% CI 1.4 to 12.8, p=0.01). A large increase in weekly handball load increases the shoulder injury rate in elite youth handball players; particularly, in the presence of reduced external rotational strength or scapular dyskinesis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Reactivity and reaction rate studies on the fourth loading of ZENITH

    International Nuclear Information System (INIS)

    Cameron, I.R.; Freemantle, R.G.; Reed, D.L.; Wilson, D.J.

    1963-08-01

    The determination of the excess reactivity, control rod worths, prompt neutron lifetime, flux fine structure, and reaction rates of various nuclides for the fourth loading of the heated zero energy reactor ZENITH is described. The core contains 7.76 kg of U235, giving a carbon/U235 atom ratio of 7578, and forms the most dilute of the range studied. Comparisons of the experimental results with calculations using multigroup diffusion codes are presented. (author)

  8. Reactivity and reaction rate studies on the fourth loading of ZENITH

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, I R; Freemantle, R G; Reed, D L; Wilson, D J [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-08-15

    The determination of the excess reactivity, control rod worths, prompt neutron lifetime, flux fine structure, and reaction rates of various nuclides for the fourth loading of the heated zero energy reactor ZENITH is described. The core contains 7.76 kg of U235, giving a carbon/U235 atom ratio of 7578, and forms the most dilute of the range studied. Comparisons of the experimental results with calculations using multigroup diffusion codes are presented. (author)

  9. Evolution of the fracture process zone in high-strength concrete under different loading rates

    Directory of Open Access Journals (Sweden)

    Cámara M.

    2010-06-01

    Full Text Available For cementitious materials, the inelastic zone around a crack tip is termed as fracture process zone (FPZ and dominated by complicated mechanism, such as microcracking, crack deflection, bridging, crack face friction, crack tip blunting by voids, crack branching, and so on. Due to the length of the FPZ is related with the characteristic length of the cementitious materials, the size, extent and location of the FPZ has been the object of countless research efforts for several decades. For instance, Cedolin et al. [1] have used an optical method based on the moiré interferometry to determine FPZ in concrete. Castro-Montero et al. [2] have applied the method of holographic interferometry to mortar to study the extension of the FPZ. The advantage of the interferometry method is that the complete FPZ can be directly observed on the surface of the sample. Swartz et al. [3] has adopted the dye penetration technique to illustrate the changing patterns observed as the crack progress from the tensile side to the compression side of the beam. Moreover, acoustic emission (AE is also an experimental technique well suited for monitoring fracture process. Haidar et al. [4] and Maji et al. [5] have studied the relation between acoustic emission characteristics and the properties of the FPZ. Compared with the extensive research on properties of the FPZ under quasi-static loading conditions, much less information is available on its dynamic characterization, especially for high-strength concrete (HSC. This paper presents the very recent results of an experimental program aimed at disclosing the loading rate effect on the size and velocity of the (FPZ in HSC. Eighteen three-point bending specimens were conducted under a wide range of loading rates from from 10-4 mm/s to 103 mm/s using either a servo-hydraulic machine or a self-designed drop-weight impact device. The beam dimensions were 100 mm 100 mm in cross section, and 420 mm in length. The initial notch

  10. The failure of brittle materials under overall compression: Effects of loading rate and defect distribution

    Science.gov (United States)

    Paliwal, Bhasker

    The constitutive behaviors and failure processes of brittle materials under far-field compressive loading are studied in this work. Several approaches are used: experiments to study the compressive failure behavior of ceramics, design of experimental techniques by means of finite element simulations, and the development of micro-mechanical damage models to analyze and predict mechanical response of brittle materials under far-field compression. Experiments have been conducted on various ceramics, (primarily on a transparent polycrystalline ceramic, aluminum oxynitride or AlON) under loading rates ranging from quasi-static (˜ 5X10-6) to dynamic (˜ 200 MPa/mus), using a servo-controlled hydraulic test machine and a modified compression Kolsky bar (MKB) technique respectively. High-speed photography has also been used with exposure times as low as 20 ns to observe the dynamic activation, growth and coalescence of cracks and resulting damage zones in the specimen. The photographs were correlated in time with measurements of the stresses in the specimen. Further, by means of 3D finite element simulations, an experimental technique has been developed to impose a controlled, homogeneous, planar confinement in the specimen. The technique can be used in conjunction with a high-speed camera to study the in situ dynamic failure behavior of materials under confinement. AlON specimens are used for the study. The statically pre-compressed specimen is subjected to axial dynamic compressive loading using the MKB. Results suggest that confinement not only increases the load carrying capacity, it also results in a non-linear stress evolution in the material. High-speed photographs also suggest an inelastic deformation mechanism in AlON under confinement which evolves more slowly than the typical brittle-cracking type of damage in the unconfined case. Next, an interacting micro-crack damage model is developed that explicitly accounts for the interaction among the micro-cracks in

  11. Measuring Cognitive Load during Simulation-Based Psychomotor Skills Training: Sensitivity of Secondary-Task Performance and Subjective Ratings

    Science.gov (United States)

    Haji, Faizal A.; Khan, Rabia; Regehr, Glenn; Drake, James; de Ribaupierre, Sandrine; Dubrowski, Adam

    2015-01-01

    As interest in applying cognitive load theory (CLT) to the study and design of pedagogic and technological approaches in healthcare simulation grows, suitable measures of cognitive load (CL) are needed. Here, we report a two-phased study investigating the sensitivity of subjective ratings of mental effort (SRME) and secondary-task performance…

  12. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    International Nuclear Information System (INIS)

    Lee, Seungmin; Seong, Poonghyun; Kim, Jonghyun

    2013-01-01

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load

  13. Nanoindentation study of size effect and loading rate effect on mechanical properties of a thin film metallic glass Cu49.3Zr50.7

    International Nuclear Information System (INIS)

    Pang Jianjun; Tan Mingjen; Liew, K.M.; Shearwood, Christopher

    2012-01-01

    A binary metallic glass (MG) Cu 49.3 Zr 50.7 in the form of thin film was successfully grown on a Si (1 0 0) substrate by magnetron sputtering. The mechanical properties, specifically, hardness and modulus at various peak loads and loading rates were characterized through instrumented nanoindentation. Unlike other metallic glasses showing an indentation size effect (ISE), the composition of this study does not have an ISE, which is phenomenologically the result of the negligible length scale according to the strain gradient plasticity model. The proportional specimen resistance model is applicable to the load-displacement behaviors and suggests that the frictional effect is too small to contribute to the ISE. The occurrence of plasticity depends on loading rates and can be delayed so that the displacement during the load holding segment increases logarithmically. In addition, the hardness and modulus are both dependent on the loading rates as well, i.e., they increase as the loading rate increases up to 0.1 mN/s and then hold constant, which is independent of creep time (≤100 s). These loading-rate-dependent behaviors are interpreted as the result of viscoelastic effect rather than free volume kinetics.

  14. Time-Dependent Behaviors of Granite: Loading-Rate Dependence, Creep, and Relaxation

    Science.gov (United States)

    Hashiba, K.; Fukui, K.

    2016-07-01

    To assess the long-term stability of underground structures, it is important to understand the time-dependent behaviors of rocks, such as their loading-rate dependence, creep, and relaxation. However, there have been fewer studies on crystalline rocks than on tuff, mudstone, and rock salt, because the high strength of crystalline rocks makes the detection of their time-dependent behaviors much more difficult. Moreover, studies on the relaxation, temporal change of stress and strain (TCSS) conditions, and relations between various time-dependent behaviors are scarce for not only granites, but also other rocks. In this study, previous reports on the time-dependent behaviors of granites were reviewed and various laboratory tests were conducted using Toki granite. These tests included an alternating-loading-rate test, creep test, relaxation test, and TCSS test. The results showed that the degree of time dependence of Toki granite is similar to other granites, and that the TCSS resembles the stress-relaxation curve and creep-strain curve. A viscoelastic constitutive model, proposed in a previous study, was modified to investigate the relations between the time-dependent behaviors in the pre- and post-peak regions. The modified model reproduced the stress-strain curve, creep, relaxation, and the results of the TCSS test. Based on a comparison of the results of the laboratory tests and numerical simulations, close relations between the time-dependent behaviors were revealed quantitatively.

  15. Mass concentration coupled with mass loading rate for evaluating PM_2_._5 pollution status in the atmosphere: A case study based on dairy barns

    International Nuclear Information System (INIS)

    Joo, HungSoo; Park, Kihong; Lee, Kwangyul; Ndegwa, Pius M.

    2015-01-01

    This study investigated particulate matter (PM) loading rates and concentrations in ambient air from naturally ventilated dairy barns and also the influences of pertinent meteorological factors, traffic, and animal activities on mass loading rates and mass concentrations. Generally, relationships between PM_2_._5 concentration and these parameters were significantly poorer than those between the PM loading rate and the same parameters. Although ambient air PM_2_._5 loading rates correlated well with PM_2_._5 emission rates, ambient air PM_2_._5 concentrations correlated poorly with PM_2_._5 concentrations in the barns. A comprehensive assessment of PM_2_._5 pollution in ambient air, therefore, requires both mass concentrations and mass loading rates. Emissions of PM_2_._5 correlated strongly and positively with wind speed, temperature, and solar radiation (R"2 = 0.84 to 0.99) and strongly but negatively with relative humidity (R"2 = 0.93). Animal activity exhibited only moderate effect on PM_2_._5 emissions, while traffic activity did not significantly affect PM_2_._5 emissions. - Highlights: • Sink PM_2_._5 loading rates correlate well with source PM_2_._5 emission rates. • Sink PM_2_._5 concentrations correlate poorly with source PM_2_._5 concentrations. • Mass loading rate complements mass concentration in appraising sink PM_2_._5 status. • PM_2_._5 emissions is dependent on wind speed, temp, solar strength, and RH. • Cow traffic activity affects PM_2_._5 emissions, while traffic activity does not. - Both PM mass loading rate and concentrations are required for comprehensive assessment of pollution potential of PM released into the atmosphere.

  16. Effect of Bench Press Load Knowledge on Repetitions, Rating of Perceived Exertion, and Attentional Focus.

    Science.gov (United States)

    Beaudoin, Christina M; Cox, Zachary; Dundore, Tyler; Thomas, Tayler; Kim, Johnathon; Pillivant, Daniel

    2018-02-01

    Beaudoin, CM, Cox, Z, Dundore, T, Thomas, T, Kim, J, and Pillivant, D. Effect of bench press load knowledge on repetitions, rating of perceived exertion, and attentional focus. J Strength Cond Res 32(2): 514-519, 2018-Few studies have examined the role of the teleoanticipation during resistance training. The purpose of this study was to examine the effect of bench press (BP) load knowledge on repetitions completed, ratings of perceived exertion (RPEs), and attentional focus (% associative). Thirty-six recreationally active resistance-trained men (n = 25) and women (n = 11) participated in this study (age = 20.97 ± 1.87 years; ht = 174.12 ± 9.41 cm; and mass = 80.14 ± 14.03 kg). All subjects completed 3 testing sessions: (a) 1 repetition maximum (1RM) BP determination; (b) submaximal BP repetitions to fatigue known load (KL); and (c) submaximal BP repetitions to fatigue unknown load (UL). Known load and UL sessions were randomized and counterbalanced and both completed at 70% 1RM. An estimated weight ratio was computed using the subject's estimate of the UL weight relative to the KL weight. An independent samples t-test revealed no significant testing order difference for the estimated weight ratio. Two-way repeated-measures analysis of variances revealed no significant differences in the number of repetitions (p = 0.63), RPE (p = 0.18), or attentional focus (% associative) (p = 0.93) between the KL and UL conditions. Pearson correlations found a moderate positive association between KL repetitions completed and % associative focus when the UL was completed before the KL. Load knowledge did not influence the number of repetitions, RPE, or attentional focus while completing the BP. Further research examining the use of pacing strategies, RPE, and attentional focus during KL and UL conditions are warranted.

  17. The Coupled Effect of Loading Rate and Grain Size on Tensile Strength of Sandstones under Dynamic Disturbance

    Directory of Open Access Journals (Sweden)

    Miao Yu

    2017-01-01

    Full Text Available It is of significance to comprehend the effects of rock microstructure on the tensile strength under different loading rates caused by mining disturbance. So, in this paper, three kinds of sandstones drilled from surrounding rocks in Xiao Jihan Coal to simulate the in situ stress state, whose average grain size is 30 μm (fine grain, FG, 105 μm (medium grain, MG, and 231 μm (Coarse grain, CG, are selected with the calculation of optical microscopic technique and moreover processed to Brazilian disc (BD to study the mechanical response of samples. The dynamic Brazilian tests of samples with three kinds of grain sizes are conducted with the Split Hopkinson Pressure Bar (SHPB driven by pendulum hammer, which can produce four different velocities (V=2.0 m/s, 2.5 m/s, 3.3 m/s, and 4.2 m/s when the incident bar is impacted by pendulum hammer. The incident wave produced by pendulum hammer is a slowly rising stress wave, which allows gradual stress accumulation in the specimen and maintains the load at both ends of the specimen in an equilibrium state. The results show that the dynamic strength of three kinds of BD samples represented loading rates dependence, and FG sandstones are more sensitive for loading rates than MG and CG samples. Moreover, the peak strength is observed to increase linearly with an increasing stress rates, and the relationship between the dynamic BD strength and stress rates can be built through a linear equation. Finally, the failure modes of different grain sizes are discussed and explained by microfailure mechanism.

  18. A Bayesian approach to infer nitrogen loading rates from crop and land-use types surrounding private wells in the Central Valley, California

    Science.gov (United States)

    Ransom, Katherine M.; Bell, Andrew M.; Barber, Quinn E.; Kourakos, George; Harter, Thomas

    2018-05-01

    This study is focused on nitrogen loading from a wide variety of crop and land-use types in the Central Valley, California, USA, an intensively farmed region with high agricultural crop diversity. Nitrogen loading rates for several crop types have been measured based on field-scale experiments, and recent research has calculated nitrogen loading rates for crops throughout the Central Valley based on a mass balance approach. However, research is lacking to infer nitrogen loading rates for the broad diversity of crop and land-use types directly from groundwater nitrate measurements. Relating groundwater nitrate measurements to specific crops must account for the uncertainty about and multiplicity in contributing crops (and other land uses) to individual well measurements, and for the variability of nitrogen loading within farms and from farm to farm for the same crop type. In this study, we developed a Bayesian regression model that allowed us to estimate land-use-specific groundwater nitrogen loading rate probability distributions for 15 crop and land-use groups based on a database of recent nitrate measurements from 2149 private wells in the Central Valley. The water and natural, rice, and alfalfa and pasture groups had the lowest median estimated nitrogen loading rates, each with a median estimate below 5 kg N ha-1 yr-1. Confined animal feeding operations (dairies) and citrus and subtropical crops had the greatest median estimated nitrogen loading rates at approximately 269 and 65 kg N ha-1 yr-1, respectively. In general, our probability-based estimates compare favorably with previous direct measurements and with mass-balance-based estimates of nitrogen loading. Nitrogen mass-balance-based estimates are larger than our groundwater nitrate derived estimates for manured and nonmanured forage, nuts, cotton, tree fruit, and rice crops. These discrepancies are thought to be due to groundwater age mixing, dilution from infiltrating river water, or denitrification

  19. Fracto-mechanoluminescent light emission of EuD4TEA-PDMS composites subjected to high strain-rate compressive loading

    Science.gov (United States)

    Ryu, Donghyeon; Castaño, Nicolas; Bhakta, Raj; Kimberley, Jamie

    2017-08-01

    The objective of this study is to understand light emission characteristics of fracto-mechanoluminescent (FML) europium tetrakis(dibenzoylmethide)-triethylammonium (EuD4TEA) crystals under high strain-rate compressive loading. As a sensing material that can play a pivotal role for the self-powered impact sensor technology, it is important to understand transformative light emission characteristics of the FML EuD4TEA crystals under high strain-rate compressive loading. First, EuD4TEA crystals were synthesized and embedded into polydimethylsiloxane (PDMS) elastomer to fabricate EuD4TEA-PDMS composite test specimens. Second, the prepared EuD4TEA-PDMS composites were tested using the modified Kolsky bar setup equipped with a high-speed camera. Third, FML light emission was captured to yield 12 bit grayscale video footage, which was processed to quantify the FML light emission. Finally, quantitative parameters were generated by taking into account pixel values and population of pixels of the 12 bit grayscale images to represent FML light intensity. The FML light intensity was correlated with high strain-rate compressive strain and strain rate to understand the FML light emission characteristics under high strain-rate compressive loading that can result from impact occurrences.

  20. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    Science.gov (United States)

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2018-04-01

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  1. Discrete dislocation plasticity analysis of loading rate-dependent static friction.

    Science.gov (United States)

    Song, H; Deshpande, V S; Van der Giessen, E

    2016-08-01

    From a microscopic point of view, the frictional force associated with the relative sliding of rough surfaces originates from deformation of the material in contact, by adhesion in the contact interface or both. We know that plastic deformation at the size scale of micrometres is not only dependent on the size of the contact, but also on the rate of deformation. Moreover, depending on its physical origin, adhesion can also be size and rate dependent, albeit different from plasticity. We present a two-dimensional model that incorporates both discrete dislocation plasticity inside a face-centred cubic crystal and adhesion in the interface to understand the rate dependence of friction caused by micrometre-size asperities. The friction strength is the outcome of the competition between adhesion and discrete dislocation plasticity. As a function of contact size, the friction strength contains two plateaus: at small contact length [Formula: see text], the onset of sliding is fully controlled by adhesion while for large contact length [Formula: see text], the friction strength approaches the size-independent plastic shear yield strength. The transition regime at intermediate contact size is a result of partial de-cohesion and size-dependent dislocation plasticity, and is determined by dislocation properties, interfacial properties as well as by the loading rate.

  2. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seungmin; Seong, Poonghyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load.

  3. Piping hydrodynamic loads for a PWR power up-rate with steam generator replacement

    International Nuclear Information System (INIS)

    Julie M Jarvis; Allen T Vieira; James M Gilmer

    2005-01-01

    Full text of publication follows: Pipe break hydrodynamic loads are calculated for various systems in a PWR for a Power Up-rate (PUR) with a Steam Generator Replacement (SGR). PUR with SGR can change the system pressures, mass flowrates and pipe routing/configuration. These changes can alter the steam generator piping steam/water hammer loads. This paper discusses the need to benchmark against the original design basis, the use of different modeling techniques, and lessons learned. Benchmarking for licensing in the United States is vital in consideration of 10CFR50.59 and other licensing and safety issues. RELAP5 and its force post-processor R5FORCE are used to model the transient loads for various piping systems such as main feedwater and blowdown systems. Other modeling applications, including the Bechtel GAFT program, are used to evaluate loadings in the main steam piping. Forces are calculated for main steam turbine stop valve closure, feedwater pipe breaks and subsequent check valve slam, and blowdown isolation valve closure. These PUR/SGR forces are compared with the original design basis forces. Modeling techniques discussed include proper valve closure modeling, sonic velocity changes due to pipe material changes, and two phase flow effects. Lessons learned based on analyses done for several PWR PUR with SGR are presented. Lessons learned from these analyses include choosing the optimal replacement piping size and routing to improve system performance without resulting in excessive piping loads. (authors)

  4. Tensile behaviour of natural fibres. Effect of loading rate, temperature and humidity on the “accommodation” phenomena

    Directory of Open Access Journals (Sweden)

    Placet V.

    2010-06-01

    Full Text Available The use of natural fibres in high performance composite requires an accurate understanding of the mechanical behaviour of the fibres themselves. As for all biobased materials, the mechanical properties of natural fibres depend generally on the testing rate and on the environmental conditions. In addition, natural fibres as hemp for example exhibit a particular mechanism of stiffness increase and accommodation phenomena under cyclic loading. Loading rate, temperature and humidity effects on the viscoelastic properties of hemp fibres were investigated in this work. The collected results clearly emphasis the involvement of time-dependant and mechano-sorptive mechanisms.

  5. Effect of Five-Finger Shoes on Vertical Ground Reaction Force Loading Rates and Perceived Comfort during the Stance Phase of the Running

    Directory of Open Access Journals (Sweden)

    Seyede Zeynab Hoseini

    2016-06-01

    Full Text Available Objective:  Increased vertical ground reaction force loading rates and lack of comfort footwear in the early stance phase can increase the risk of overuse injuries. The purpose of this study was to investigate the effect of Five-finger shoes on vertical ground reaction force loading rate and perceived comfort during the stance phase of running. Methods: 15 male students (aged 24 ± 5/24 years, weight 75/8 ± 4/61 kg, height 178/6 ± 6/64 cm were selected. Subjects were asked to run over a force plate, in control shoe, five finger shoe and barefoot conditions. Loading rate using the slope of the vertical reaction force and perceived comfort were determined using a visual analogue scale. One factor repeated measures ANOVA was used to test the loading rate hypothesis and Paired t-tests was used to test the meaningfulness of perceived comfort (P<0/05. Results: The effect of shoes on loading rate was found to be not significant (P=0.1. However, comfort of control shoes increased by 10. 92% as compared to that of five-finger shoes (P=0.001.  Conclusion: The loading rate of five-finger shoes is the same as that of barefoot during running; however, as subjects did not perceive them as comfortable as regular shoes are five-finger shoes cannot be advised as a desirable choice in exercises.

  6. Effect of loading rate on creep of phosphorous doped copper

    Energy Technology Data Exchange (ETDEWEB)

    Andersson-Oestling, Henrik C.M.; Sandstroem, Rolf (Swerea KIMAB (Sweden))

    2011-12-15

    Creep testing of copper intended for nuclear waste disposal has been performed on continuous creep tests machines at a temperature of 75 deg C. The loading time has been varied from 1 hour to 6 months. The rupture strain including both loading and creep strains does not differ from traditional dead weight lever creep test rigs. The loading strain increases with increasing loading time, at the expense of the creep strain. The time dependence of the creep strain has been modelled taking athermal plastic deformation and creep into account. During loading the contribution to the strain from the athermal plastic deformation dominates until the stress is close to the constant load level. When the constant load has been reached there is no more athermal strain and all of the strain comes from creep

  7. Direct Numerical Simulations of Microstructure Effects During High-Rate Loading of Additively Manufactured Metals

    Science.gov (United States)

    Battaile, Corbett; Owen, Steven; Moore, Nathan

    2017-06-01

    The properties of most engineering materials depend on the characteristics of internal microstructures and defects. In additively manufactured (AM) metals, these can include polycrystalline grains, impurities, phases, and significant porosity that qualitatively differ from conventional engineering materials. The microscopic details of the interactions between these internal defects, and the propagation of applied loads through the body, act in concert to dictate macro-observable properties like strength and compressibility. In this work, we used Sandia's ALEGRA finite element software to simulate the high-strain-rate loading of AM metals from laser engineered net shaping (LENS) and thermal spraying. The microstructural details of the material were represented explicitly, such that internal features like second phases and pores are captured and meshed as individual entities in the computational domain. We will discuss the dependence of the high-strain-rate mechanical properties on microstructural characteristics such as the shapes, sizes, and volume fractions of second phases and pores. In addition, we will examine how the details of the microstructural representation affect the microscopic material response to dynamic loads, and the effects of using ``stair-step'' versus conformal interfaces smoothed via the SCULPT tool in Sandia's CUBIT software. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the US DOE NNSA under contract DE-AC04-94AL85000.

  8. The effects of working memory load and attention refocusing on delay discounting rates in alcohol use disorder with comorbid antisocial personality disorder.

    Science.gov (United States)

    Gunn, Rachel L; Gerst, Kyle R; Lake, Allison J; Finn, Peter R

    2018-02-01

    Executive working memory capacity (eWMC) is central to adaptive decision-making. Research has revealed reduced eWMC and higher rates of impulsive decision making in individuals with alcohol use disorders (AUDs: DSM-IV Alcohol Dependence of Alcohol Abuse) and antisocial psychopathology (AP). Recent work has shown that placing a load on working memory (WM) further increases impulsive decision making on the delay discounting (DD) task in those with AUDs and AP. The current study examined the effects of an attention refocusing manipulation to offset the effects of this WM-load on DD rates in control subjects, those with AUDs without AP, and AUDs with AP (AUD-AP). Results revealed that 1) the AUD-AP group had higher DD rates (i.e., more impulsive decision-making) than the AUD group, followed by controls, and 2) attention refocusing after a load is placed on WM was associated with lower DD rates compared to the load without refocusing in both AUD groups, but not controls. Results suggest that refocusing attention after a cognitive load may be an effective cognitive strategy for reducing the impulsivity-enhancing effects of cognitive load on decision making in individuals with AUDs and AP. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Duration of off-loading and recurrence rate in Charcot osteo-arthropathy treated with less restrictive regimen with removable walker

    DEFF Research Database (Denmark)

    Christensen, Tomas M; Gade-Rasmussen, Birthe; Pedersen, Lis W

    2013-01-01

    Recent literature on acute diabetic Charcot osteoarthropathy (CA) reports unusually long periods of off-loading. Data suggest that this might increase the re-currence rate. Subsequently we evaluated the influence of duration of off-loading on the risk of required re-casting....

  10. Anaerobic co-digestion of food waste and dairy manure: effects of food waste particle size and organic loading rate.

    Science.gov (United States)

    Agyeman, Fred O; Tao, Wendong

    2014-01-15

    This study was to comprehensively evaluate the effects of food waste particle size on co-digestion of food waste and dairy manure at organic loading rates increased stepwise from 0.67 to 3 g/L/d of volatile solids (VS). Three anaerobic digesters were fed semi-continuously with equal VS amounts of food waste and dairy manure. Food waste was ground to 2.5 mm (fine), 4 mm (medium), and 8 mm (coarse) for the three digesters, respectively. Methane production rate and specific methane yield were significantly higher in the digester with fine food waste. Digestate dewaterability was improved significantly by reducing food waste particle size. Specific methane yield was highest at the organic loading rate of 2g VS/L/d, being 0.63, 0.56, and 0.47 L CH4/g VS with fine, medium, and coarse food waste, respectively. Methane production rate was highest (1.40-1.53 L CH4/L/d) at the organic loading rate of 3 g VS/L/d. The energy used to grind food waste was minor compared with the heating value of the methane produced. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Dry fermentation of manure with straw in continuous plug flow reactor: Reactor development and process stability at different loading rates.

    Science.gov (United States)

    Patinvoh, Regina J; Kalantar Mehrjerdi, Adib; Sárvári Horváth, Ilona; Taherzadeh, Mohammad J

    2017-01-01

    In this work, a plug flow reactor was developed for continuous dry digestion processes and its efficiency was investigated using untreated manure bedded with straw at 22% total solids content. This newly developed reactor worked successfully for 230days at increasing organic loading rates of 2.8, 4.2 and 6gVS/L/d and retention times of 60, 40 and 28days, respectively. Organic loading rates up to 4.2gVS/L/d gave a better process stability, with methane yields up to 0.163LCH 4 /gVS added /d which is 56% of the theoretical yield. Further increase of organic loading rate to 6gVS/L/d caused process instability with lower volatile solid removal efficiency and cellulose degradation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Plastic limit loads for cylindrical shell intersections under combined loading

    International Nuclear Information System (INIS)

    Skopinsky, V.N.; Berkov, N.A.; Vogov, R.A.

    2015-01-01

    In this research, applied methods of nonlinear analysis and results of determining the plastic limit loads for shell intersection configurations under combined internal pressure, in-plane moment and out-plane moment loadings are presented. The numerical analysis of shell intersections is performed using the finite element method, geometrically nonlinear shell theory in quadratic approximation and plasticity theory. For determining the load parameter of proportional combined loading, the developed maximum criterion of rate of change of relative plastic work is employed. The graphical results for model of cylindrical shell intersection under different two-parameter combined loadings (as generalized plastic limit load curves) and three-parameter combined loading (as generalized plastic limit load surface) are presented on the assumption that the internal pressure, in-plane moment and out-plane moment loads were applied in a proportional manner. - Highlights: • This paper presents nonlinear two-dimensional FE analysis for shell intersections. • Determining the plastic limit loads under combined loading is considered. • Developed maximum criterion of rate of change of relative plastic work is employed. • Plastic deformation mechanism in shell intersections is discussed. • Results for generalized plastic limit load curves of branch intersection are presented

  13. Post Oil America and a Renewable Energy Policy Leads to the Abrogation of the Middle East to China

    Science.gov (United States)

    2009-04-01

    Pollack, “Securing the Gulf,” Foreign Affairs 82, no. 4 (Jul/Aug 2003): 2. 7 Ian Rutledge, Addicted to Oil: America’s Relentless Drive for Energy... whale oil and other animal fats to fuel lamps, until 1886 23 “The Story of Oil in...February 11, 2009). Rutledge, Ian. Addicted to Oil: America’s Relentless Drive for Energy Security. London: I.B. Tauris, 2005. Safran, Nadav. Saudi

  14. Modelling of pile load tests in granular soils : Loading rate effects

    NARCIS (Netherlands)

    Nguyen, T.C.

    2017-01-01

    People have used pile foundations throughout history to support structures by transferring
    loads to deeper and stronger soil layers. One of the most important questions during the design of the pile foundation is the bearing capacity of the pile. The most reliable method for determining the

  15. Loading Rate Effects on the One-Dimensional Compressibility of Four Partially Saturated Soils

    Science.gov (United States)

    1986-12-01

    representations are referred to as constitutive models. Numerous constitutive models incorporating loading rate effects have been developed ( Baladi and Rohani...and probably more indicative of the true values of applied pressure and average strain produced during the test. A technique developed by Baladi and...Sand," Technical Report No. AFWL-TR-66-146, Air Force Weapons Laboratory, Kirtland Air Force Base, New Mexico, June, 1967. 4. Baladi , George Y., and

  16. Fracture toughness evaluation of small notched specimen in consideration of notch effect and loading rate

    International Nuclear Information System (INIS)

    Lee, Baik Woo; Kwon, Dong Il; Jang, Jae Il

    2000-01-01

    Notch effect and loading rate dependency on fracture toughness were considered when evaluating fracture toughness of small notched specimens using the instrumented impact test. Notch effect was analyzed into stress redistribution effect and stress relaxation with a viewpoint of stress triaxiality. Stress redistribution effect was corrected by introducing effective crack length, which was the sum of actual crack length and plastic zone size. Stress relaxation effect was also corrected using elastic stress concentration factor, which would decrease if plastic deformation occurred. As a result, corrected fracture toughness of the notched specimen was very consistent with the reference fracture toughness obtained using precracked specimen. In addition, limiting notch root radius, below which fracture toughness was independent of notch radius, was observed and discussed. Loading rate dependency on fracture toughness, which was obtained from the static three point bending test and the instrumented impact test, was also discussed with stress field in plastic zone ahead of a notch and fracture based on stress control mechanism. (author)

  17. Load bearing and deformation behaviour of dynamically loaded wide plate specimens

    International Nuclear Information System (INIS)

    Julisch, P.; Haedrich, H.J.; Stadtmueller, W.; Sturm, D.

    1989-01-01

    For the testing of large-scale specimens, a 12 MN-High Loading Rate Tensile Testing Machine was designed and built at MPA Stuttgart. The aim was to determine the influence of high loading rates on the stress and strain behaviour of unwelded and welded components of ferritic and austenitic materials. This new generation of testing machines is driven by a propellant charge, and generates a maximum tensile force of 12 MN with a piston velocity of 25 m/s after a stroke of 20 mm, or a maximum velocity of 60 m/s after a stroke of 400 mm. In a first test programme, welded and unwelded wide plate specimens made of material X 6 CrNi 18 11 were tested at room temperature with different strain rates from 10 -3 /s to 63/s. In addition to a description of the 12 MN-High Loading Rate Tensile Testing Machine, the results of the high loading rate tensile tests performed will be presented and compared with quasistatically tested wide plate specimens. (orig.)

  18. Effects of Surface Inclination on the Vertical Loading Rates and Landing Pattern during the First Attempt of Barefoot Running in Habitual Shod Runners

    Science.gov (United States)

    An, W.; Rainbow, M. J.; Cheung, R. T. H.

    2015-01-01

    Barefoot running has been proposed to reduce vertical loading rates, which is a risk factor of running injuries. Most of the previous studies evaluated runners on level surfaces. This study examined the effect of surface inclination on vertical loading rates and landing pattern during the first attempt of barefoot running among habitual shod runners. Twenty habitual shod runners were asked to run on treadmill at 8.0 km/h at three inclination angles (0°; +10°; −10°) with and without their usual running shoes. Vertical average rate (VALR) and instantaneous loading rate (VILR) were obtained by established methods. Landing pattern was decided using high-speed camera. VALR and VILR in shod condition were significantly higher (p running, but not in barefoot condition (p > 0.382). There was no difference (p > 0.413) in the landing pattern among all surface inclinations. Only one runner demonstrated complete transition to non-heel strike landing in all slope conditions. Reducing heel strike ratio in barefoot running did not ensure a decrease in loading rates (p > 0.15). Conversely, non-heel strike landing, regardless of footwear condition, would result in a softer landing (p < 0.011). PMID:26258133

  19. Effects of Surface Inclination on the Vertical Loading Rates and Landing Pattern during the First Attempt of Barefoot Running in Habitual Shod Runners

    Directory of Open Access Journals (Sweden)

    W. An

    2015-01-01

    Full Text Available Barefoot running has been proposed to reduce vertical loading rates, which is a risk factor of running injuries. Most of the previous studies evaluated runners on level surfaces. This study examined the effect of surface inclination on vertical loading rates and landing pattern during the first attempt of barefoot running among habitual shod runners. Twenty habitual shod runners were asked to run on treadmill at 8.0 km/h at three inclination angles (0°; +10°; −10° with and without their usual running shoes. Vertical average rate (VALR and instantaneous loading rate (VILR were obtained by established methods. Landing pattern was decided using high-speed camera. VALR and VILR in shod condition were significantly higher (p0.382. There was no difference (p>0.413 in the landing pattern among all surface inclinations. Only one runner demonstrated complete transition to non-heel strike landing in all slope conditions. Reducing heel strike ratio in barefoot running did not ensure a decrease in loading rates (p>0.15. Conversely, non-heel strike landing, regardless of footwear condition, would result in a softer landing (p<0.011.

  20. Effects of Surface Inclination on the Vertical Loading Rates and Landing Pattern during the First Attempt of Barefoot Running in Habitual Shod Runners.

    Science.gov (United States)

    An, W; Rainbow, M J; Cheung, R T H

    2015-01-01

    Barefoot running has been proposed to reduce vertical loading rates, which is a risk factor of running injuries. Most of the previous studies evaluated runners on level surfaces. This study examined the effect of surface inclination on vertical loading rates and landing pattern during the first attempt of barefoot running among habitual shod runners. Twenty habitual shod runners were asked to run on treadmill at 8.0 km/h at three inclination angles (0°; +10°; -10°) with and without their usual running shoes. Vertical average rate (VALR) and instantaneous loading rate (VILR) were obtained by established methods. Landing pattern was decided using high-speed camera. VALR and VILR in shod condition were significantly higher (p running, but not in barefoot condition (p > 0.382). There was no difference (p > 0.413) in the landing pattern among all surface inclinations. Only one runner demonstrated complete transition to non-heel strike landing in all slope conditions. Reducing heel strike ratio in barefoot running did not ensure a decrease in loading rates (p > 0.15). Conversely, non-heel strike landing, regardless of footwear condition, would result in a softer landing (p < 0.011).

  1. EFFECTS OF BURN RATE, WOOD SPECIES, MOISTURE CONTENT AND WEIGHT OF WOOD LOADED ON WOODSTOVE EMISSIONS

    Science.gov (United States)

    The report gives results of tests of four woodstove operating parameters (burn rate, wood moisture, wood load, and wood species) at two levels each using a half factorial experimental test design to determine statistically significant effects on the emission components CO, CO2, p...

  2. A new islanding detection technique for multiple mini hydro based on rate of change of reactive power and load connecting strategy

    International Nuclear Information System (INIS)

    Laghari, J.A.; Mokhlis, H.; Bakar, A.H.A.; Karimi, M.

    2013-01-01

    Highlights: • The requirement of DG interconnection with existing power system is discussed. • Various islanding detection techniques are discussed with their merits and demerits. • New islanding detection strategy is proposed for multiple mini hydro type DGs. • The proposed strategy is based on dq/dt and load connecting strategy. • The effectiveness of strategy is verified on various other cases. - Abstract: The interconnection of distributed generation (DG) into distribution networks is undergoing a rapid global expansion. It enhances the system’s reliability, while simultaneously reduces pollution problems related to the generation of electrical power. To fully utilize the benefits of DGs, certain technical issues need to be addressed. One of the most important issues in this context is islanding detection. This paper presents a new islanding detection technique that is suitable for multiple mini-hydro type DG units. The proposed strategy is based on the rate of change of reactive power and load connecting strategy to detect islanding within the system. For a large power mismatch, islanding is detected by rate of change of reactive power only. However, for a close power mismatch, the rate of change of reactive power initiates a load connecting strategy, which in turn alters the load on the distribution network. This load variation in the distribution network causes a variation in the rate of change of reactive power, which is utilized to distinguish islanding and other events. The simulation results show that the proposed strategy is effective in detecting islanding occurrence in a distribution network

  3. Strain rate dependent deformation and failure behavior of laser welded DP780 steel joint under dynamic tensile loading

    International Nuclear Information System (INIS)

    Liu, Yang; Dong, Danyang; Wang, Lei; Chu, Xi; Wang, Pengfei; Jin, Mengmeng

    2015-01-01

    Laser welded DP steel joints are used widely in the automotive industry for weight reduction. Understanding the deformation and fracture behavior of the base metal (BM) and its welded joint (WJ), especially at high strain rates, is critical for the design of vehicle structures. This paper is concerned with the effects of strain rate on the tensile properties, deformation and fracture behavior of the laser welded DP780 steel joint. Quasi-static and dynamic tensile tests were performed on the WJ and BM of the DP780 steel using an electromechanical universal testing machine and a high-speed tensile testing machine over a wide range of strain rate (0.0001–1142 s −1 ). The microstructure change and microhardness distribution of the DP780 steel after laser welding were examined. Digital image correlation (DIC) and high-speed photography were employed for the strain measurement of the DP780 WJ during dynamic tensile tests. The DP780 WJ is a heterogeneous structure with hardening in fusion zone (FZ) and inner heat-affected zone (HAZ), and softening in outer HAZ. The DP780 BM and WJ exhibit positive strain rate dependence on the YS and UTS, which is smaller at lower strain rates and becomes larger with increasing strain rate, while ductility in terms of total elongation (TE) tends to increase under dynamic loading. Laser welding leads to an overall reduction in the ductility of the DP780 steel. However, the WJ exhibits a similar changing trend of the ductility to that of the BM with respect to the strain rate over the whole strain rate range. As for the DP780 WJ, the distance of tensile failure location from the weld centerline decreases with increasing strain rate. The typical ductile failure characteristics of the DP780 BM and WJ do not change with increasing strain rate. DIC measurements reveal that the strain localization starts even before the maximum load is attained in the DP780 WJ and gradual transition from uniform strains to severely localized strains occurs

  4. Strain rate dependent deformation and failure behavior of laser welded DP780 steel joint under dynamic tensile loading

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang, E-mail: liuyang@mail.neu.edu.cn [Key Laboratory for Anisotropy and Texture of Materials, Ministry of Education, Northeastern University, Shenyang 110819 (China); Dong, Danyang, E-mail: dongdanyang@mail.neu.edu.cn [College of Science, Northeastern University, Shenyang 110819 (China); Wang, Lei, E-mail: wanglei@mail.neu.edu.cn [Key Laboratory for Anisotropy and Texture of Materials, Ministry of Education, Northeastern University, Shenyang 110819 (China); Chu, Xi, E-mail: chuxi.ok@163.com [College of Science, Northeastern University, Shenyang 110819 (China); Wang, Pengfei, E-mail: wpf1963871400@163.com [College of Science, Northeastern University, Shenyang 110819 (China); Jin, Mengmeng, E-mail: 24401878@163.com [College of Science, Northeastern University, Shenyang 110819 (China)

    2015-03-11

    Laser welded DP steel joints are used widely in the automotive industry for weight reduction. Understanding the deformation and fracture behavior of the base metal (BM) and its welded joint (WJ), especially at high strain rates, is critical for the design of vehicle structures. This paper is concerned with the effects of strain rate on the tensile properties, deformation and fracture behavior of the laser welded DP780 steel joint. Quasi-static and dynamic tensile tests were performed on the WJ and BM of the DP780 steel using an electromechanical universal testing machine and a high-speed tensile testing machine over a wide range of strain rate (0.0001–1142 s{sup −1}). The microstructure change and microhardness distribution of the DP780 steel after laser welding were examined. Digital image correlation (DIC) and high-speed photography were employed for the strain measurement of the DP780 WJ during dynamic tensile tests. The DP780 WJ is a heterogeneous structure with hardening in fusion zone (FZ) and inner heat-affected zone (HAZ), and softening in outer HAZ. The DP780 BM and WJ exhibit positive strain rate dependence on the YS and UTS, which is smaller at lower strain rates and becomes larger with increasing strain rate, while ductility in terms of total elongation (TE) tends to increase under dynamic loading. Laser welding leads to an overall reduction in the ductility of the DP780 steel. However, the WJ exhibits a similar changing trend of the ductility to that of the BM with respect to the strain rate over the whole strain rate range. As for the DP780 WJ, the distance of tensile failure location from the weld centerline decreases with increasing strain rate. The typical ductile failure characteristics of the DP780 BM and WJ do not change with increasing strain rate. DIC measurements reveal that the strain localization starts even before the maximum load is attained in the DP780 WJ and gradual transition from uniform strains to severely localized strains

  5. Sample intake position and loading rates from nonpoint source pollution

    Science.gov (United States)

    McGuire, P. E.; Daniel, T. C.; Stoffel, D.; Andraski, B.

    1980-01-01

    Paired water samples were simultaneously activated from two different vertical positions within the approach section of a flow-control structure to determine the effect of sample intake position on nonpoint runoff parameter concentrations and subsequent event loads. Suspended solids (SS), total phosphorus (TP) and organic plus exchangeable nitrogen [(Or+Ex)-N] were consistently higher throughout each runoff event when sampled from the floor of the approach section as opposed to those samples taken at midstage. Dissolved molybdate reactive phosphorus (DMRP) and ammonium (NH4-N) concentrations did not appear to be significantly affected by the vertical difference in intake position. However, the nitrate plus nitrite nitrogen [(NO3+NO2)-N] concentrations were much higher when sampled from the midstage position. Although the concentration differences between the two methods were not appreciable, when evaluated in terms of event loads, discrepancies were evident for all parameters. Midstage sampling produced event loads for SS, TP, (Or + Ex)-N, DMRP, NH4-N, and (NO3+NO2)-N that were 44,39,35,80,71, and 181%, respectively, of floor sampling loads. Differences in loads between the two methods are attributed to the midstage position, sampling less of the bed load. The correct position will depend on the objective; however, such differences should be recognized during the design phase of the monitoring program.

  6. Advanced bridge safety initiative, task 1 : development of improved analytical load rating procedures for flat-slab concrete bridges - a thesis and guidelines.

    Science.gov (United States)

    2010-01-01

    Current AASHTO provisions for the conventional load rating of flat slab bridges rely on the equivalent strip method : of analysis for determining live load effects, this is generally regarded as overly conservative by many professional : engineers. A...

  7. Comparison of heavy metal loads in stormwater runoff from major and minor urban roads using pollutant yield rating curves

    International Nuclear Information System (INIS)

    Davis, Brett; Birch, Gavin

    2010-01-01

    Trace metal export by stormwater runoff from a major road and local street in urban Sydney, Australia, is compared using pollutant yield rating curves derived from intensive sampling data. The event loads of copper, lead and zinc are well approximated by logarithmic relationships with respect to total event discharge owing to the reliable appearance of a first flush in pollutant mass loading from urban roads. Comparisons of the yield rating curves for these three metals show that copper and zinc export rates from the local street are comparable with that of the major road, while lead export from the local street is much higher, despite a 45-fold difference in traffic volume. The yield rating curve approach allows problematic environmental data to be presented in a simple yet meaningful manner with less information loss. - A simple method for representing data onroad runoff pollution allows comparisons among dissimilar sites and could form the basis for a pollution database.

  8. Emission of formaldehyde by particleboard : effect of ventilation rate and loading on air-contamination levels

    Science.gov (United States)

    George E. Myers; Muneo Nagaoka

    1981-01-01

    Dynamic tests for determining the formaldehyde emission behavior of UF-bonded boards involve the measurement of formaldehyde concentration in the air within a vessel which contains a specified board loading L (m2 of board area per m3 of vessel free volume) and is being ventilated at a specified air exchange rate N (hr.-1). Such tests constitute a primary...

  9. Impact of Exchange Rate Movements, Global Economic Activity, and the BDI Volatility on Loaded Port Cargo Throughput in South Korea

    Directory of Open Access Journals (Sweden)

    Chang Beom Kim

    2016-12-01

    Full Text Available This study examines the effects of exchange rate movements, global economic activity, and the volatility of the Baltic Dry Index (BDI on South Korea's loaded port cargo throughput, based on monthly data for the period from January 2000 to October 2014. The results indicate that the BDI volatility has a negative effect on the loaded cargo throughput, while increases in the nominal exchange rate and in global economy activity have a positive effect. In addition, the error correction model results show that the error correction term is statistically significant with the negative sign.

  10. Age-specific incidence rates for dementia and Alzheimer disease in NIA-LOAD/NCRAD and EFIGA families: National Institute on Aging Genetics Initiative for Late-Onset Alzheimer Disease/National Cell Repository for Alzheimer Disease (NIA-LOAD/NCRAD) and Estudio Familiar de Influencia Genetica en Alzheimer (EFIGA).

    Science.gov (United States)

    Vardarajan, Badri N; Faber, Kelley M; Bird, Thomas D; Bennett, David A; Rosenberg, Roger; Boeve, Bradley F; Graff-Radford, Neill R; Goate, Alison M; Farlow, Martin; Sweet, Robert A; Lantigua, Rafael; Medrano, Martin Z; Ottman, Ruth; Schaid, Daniel J; Foroud, Tatiana M; Mayeux, Richard

    2014-03-01

    Late-onset Alzheimer disease (LOAD), defined as onset of symptoms after age 65 years, is the most common form of dementia. Few reports investigate incidence rates in large family-based studies in which the participants were selected for family history of LOAD. To determine the incidence rates of dementia and LOAD in unaffected members in the National Institute on Aging Genetics Initiative for Late-Onset Alzheimer Disease/National Cell Repository for Alzheimer Disease (NIA-LOAD/NCRAD) and Estudio Familiar de Influencia Genetica en Alzheimer (EFIGA) family studies. Families with 2 or more affected siblings who had a clinical or pathological diagnosis of LOAD were recruited as a part of the NIA-LOAD/NCRAD Family Study. A cohort of Caribbean Hispanics with familial LOAD was recruited in a different study at the Taub Institute for Research on Alzheimer's Disease and the Aging Brain in New York and from clinics in the Dominican Republic as part of the EFIGA study. Age-specific incidence rates of LOAD were estimated in the unaffected family members in the NIA-LOAD/NCRAD and EFIGA data sets. We restricted analyses to families with follow-up and complete phenotype information, including 396 NIA-LOAD/NCRAD and 242 EFIGA families. Among the 943 at-risk family members in the NIA-LOAD/NCRAD families, 126 (13.4%) developed dementia, of whom 109 (86.5%) met criteria for LOAD. Among 683 at-risk family members in the EFIGA families, 174 (25.5%) developed dementia during the study period, of whom 145 (83.3%) had LOAD. The annual incidence rates of dementia and LOAD in the NIA-LOAD/NCRAD families per person-year were 0.03 and 0.03, respectively, in participants aged 65 to 74 years; 0.07 and 0.06, respectively, in those aged 75 to 84 years; and 0.08 and 0.07, respectively, in those 85 years or older. Incidence rates in the EFIGA families were slightly higher, at 0.03 and 0.02, 0.06 and 0.05, 0.10 and 0.08, and 0.10 and 0.07, respectively, in the same age groups. Contrasting these

  11. Fatigue crack growth rate of API X70 steel pipelines under spectrum loading

    International Nuclear Information System (INIS)

    Beden, S.M.; Abdullah, S.; Ariffin, A.K.

    2012-01-01

    Pipelines offer the most efficient way to transport bulk quantities of gas and oil, either from points of production to storage locations or from storage locations to distributed points of end use. As one of the main materials of west–east gas transmission pipes, X70 pipelines usually serve under variable amplitude loading (VAL). Base on the importance of in-service API X70 pipelines, it is important for the safe operation of this system to know its behaviour under VAL. This paper focuses on the ability of using the NASGRO model to predict the fatigue crack growth (FCG), based on investigation with the modified Wheeler model and experimental data. The results show that the NASGRO model give a fatigue life near by to that published in literatures and also showed the FCG rate response of X70 pipeline steels when exposed to VAL with different overload values. Extra modification to the NASGRO model may lead to better representing of FCG rate. Highlights: ► The assessment of fatigue crack propagation under different load histories are proposed and presented in this paper. ► Due to lack of knowledge in the related area, as yet no universal model exists. ► The output was based on both simulation and experiments. The simulation part was carried out based on the NASGRO model. ► This work focus on fatigue crack growth (FCG) and fatigue life based on the comparison with the previous work.

  12. Radioiodination of cyclin dependent kinase inhibitor Olomoucine loaded Fe rate at Au nanoparticle and evaluation of the therapeutic efficacy on cancerous cells

    Energy Technology Data Exchange (ETDEWEB)

    Takan, Gokhan; Guldu, Ozge Kozgus; Medine, Emin Ilker [Ege Univ., Izmir (Turkey). Dept. of Nuclear Applications

    2017-06-01

    Magnetic nanoparticles have promising biomedical applications such as drug delivery, novel therapeutics and diagnostic imaging. Magnetic drug delivery combination works on the delivery of magnetic nanoparticles loaded with drug to the target tissue by means of an external magnetic field. Gold coated iron oxide (Fe rate at Au) nanoparticles can provide useful surface chemistry and biological reactivity. Covalent conjugation to the Fe rate at Au nanoparticles through cleavable linkages can be used to deliver drugs to tumor cells, then the drug can be released by an external. In this paper, purine based cyclin dependent kinases (CDKs) inhibitor Olomoucine (Olo) [2-(Hydroxyethylamino)-6-benzylamino-9-methylpurine] was loaded on gold coated iron oxide (Fe rate at Au) nanoparticles and radiolabeled with {sup 131}I to combine magnetic targeted drug delivery and radiotherapy. Fe rate at Au nanoparticles were synthesized by microemulsion method. The characterization of nanoparticles was examined by TEM, VSM and XRD. Amine activation was utilized by cysteamine hydrochloride and then CDI was used for conjugation of Olomoucine. Antiproliferative effect and cytotoxicity of Olomoucine loaded Fe rate at Au nanoparticles (Fe rate at Au-Olo) were investigated on MCF7 and A549 cell lines. Proliferation rate was decreased while uptake of Fe rate at Au-Olo on both cell lines was high in comparison with Olomoucine. Also, enhanced incorporation ratio was observed under external magnetic field.

  13. Radioiodination of cyclin dependent kinase inhibitor Olomoucine loaded Fe rate at Au nanoparticle and evaluation of the therapeutic efficacy on cancerous cells

    International Nuclear Information System (INIS)

    Takan, Gokhan; Guldu, Ozge Kozgus; Medine, Emin Ilker

    2017-01-01

    Magnetic nanoparticles have promising biomedical applications such as drug delivery, novel therapeutics and diagnostic imaging. Magnetic drug delivery combination works on the delivery of magnetic nanoparticles loaded with drug to the target tissue by means of an external magnetic field. Gold coated iron oxide (Fe rate at Au) nanoparticles can provide useful surface chemistry and biological reactivity. Covalent conjugation to the Fe rate at Au nanoparticles through cleavable linkages can be used to deliver drugs to tumor cells, then the drug can be released by an external. In this paper, purine based cyclin dependent kinases (CDKs) inhibitor Olomoucine (Olo) [2-(Hydroxyethylamino)-6-benzylamino-9-methylpurine] was loaded on gold coated iron oxide (Fe rate at Au) nanoparticles and radiolabeled with "1"3"1I to combine magnetic targeted drug delivery and radiotherapy. Fe rate at Au nanoparticles were synthesized by microemulsion method. The characterization of nanoparticles was examined by TEM, VSM and XRD. Amine activation was utilized by cysteamine hydrochloride and then CDI was used for conjugation of Olomoucine. Antiproliferative effect and cytotoxicity of Olomoucine loaded Fe rate at Au nanoparticles (Fe rate at Au-Olo) were investigated on MCF7 and A549 cell lines. Proliferation rate was decreased while uptake of Fe rate at Au-Olo on both cell lines was high in comparison with Olomoucine. Also, enhanced incorporation ratio was observed under external magnetic field.

  14. Association between minor loading vein architecture and light- and CO2-saturated rates of photosynthetic oxygen evolution among Arabidopsis thaliana ecotypes from different latitudes

    Directory of Open Access Journals (Sweden)

    Christopher M Cohu

    2013-07-01

    Full Text Available Through microscopic analysis of veins and assessment of light- and CO2-saturated rates of photosynthetic oxygen evolution, we investigated the relationship between minor loading vein anatomy and photosynthesis of mature leaves in three ecotypes of Arabidopsis thaliana grown under four different combinations of temperature and photon flux density (PFD. All three ecotypes exhibited greater numbers and cross-sectional area of phloem cells as well as higher photosynthesis rates in response to higher PFD and especially lower temperature. The Swedish ecotype exhibited the strongest response to these conditions, the Italian ecotype the weakest response, and the Col-0 ecotype exhibited an intermediate response. Among all three ecotypes, strong linear relationships were found between light- and CO2-saturated rates of photosynthetic oxygen evolution and the number and area of either sieve elements or of companion and phloem parenchyma cells in foliar minor loading veins, with the Swedish ecotype showing the highest number of cells in minor loading veins (and largest minor veins coupled with unprecedented high rates of photosynthesis. Linear, albeit less significant, relationships were also observed between number and cross-sectional area of tracheids per minor loading vein versus light- and CO2-saturated rates of photosynthetic oxygen evolution. We suggest that sugar distribution infrastructure in the phloem is co-regulated with other features that set the upper limit for photosynthesis. The apparent genetic differences among Arabidopsis ecotypes should allow for future identification of the gene(s involved in augmenting sugar-loading and -transporting phloem cells and maximal rates of photosynthesis.

  15. Using Pulse Rate in Estimating Workload Evaluating a Load Mobilizing Activity

    Directory of Open Access Journals (Sweden)

    Juan Alberto Castillo

    2014-06-01

    Full Text Available Introduction: The pulse rate is a direct indicator of the state of the cardiovascular system, in ad-dition to being an indirect indicator of the energy expended in performing a task. The pulse of a person is the number of pulses recorded in a peripheral artery per unit time; the pulse appears as a pressure wave moving along the blood vessels, which are flexible, “in large arterial branches, speed of 7-10 m/s in the small arteries, 15 to 35 m/s”. Materials and methods: The aim of this study was to assess heart rate, using the technique of recording the frequency of the pulse, oxy-gen consumption and observation of work activity in the estimation of the workload in a load handling task for three situations: lift/transfer/deposit; before, during and after the task the pulse rate is recorded for 24 young volunteers (10 women and 14 men under laboratory conditions. We performed a gesture analysis of work activity and lifting and handling strategies. Results: We observed an increase between initial and final fp in both groups and for the two tasks, a dif¬ference is also recorded in the increase in heart rate of 17.5 for charging 75 % of the participants experienced an increase in fp above 100 lat./min. Par 25 kg, registered values indicate greater than 114 lat./min and 17.5 kg than 128 lat./min values. Discussion: The pulse rate method is recommended for its simplicity of use for operational staff, supervisors and managers and indus¬trial engineers not trained in the physiology method can also be used by industrial hygienists.

  16. Effects of feeding and organism loading rate on PCB accumulation by Lumbriculus variegatus in sediment bioaccumulation testing

    Science.gov (United States)

    Sediment bioaccumulation test methods published by USEPA and ASTM in 2000 specify that the Lumbriculus variegatus, a freshwater oligochaete, should not be fed during the 28-day exposure and recommends an organism loading rate of total organic carbon in sediment to organism dry we...

  17. Direct Load Control (DLC) Considering Nodal Interrupted Energy Assessment Rate (NIEAR) in Restructured Power Systems

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Wang, Peng; Goel, Lalit

    2010-01-01

    is used as the bids from the ACL customers, is utilized to determine the direct monetary compensation to the ACL customers. The proposed scheme was investigated for the PoolCo electricity market. The optimal DLC scheme is determined based on the minimum system operating cost which is comprised......A direct load control (DLC) scheme of air conditioning loads (ACL) considering direct monetary compensation to ACL customers for the service interruption caused by the DLC program is proposed in this paper for restructured power systems. The nodal interrupted energy assessment rate (NIEAR), which...... of the system energy cost, the system spinning reserve cost and the compensation cost to the ACL customers. Dynamic programming (DP) was used to obtain the optimal DLC scheme. The IEEE reliability test system (RTS) was studied to illustrate the proposed DLC scheme....

  18. Dynamic Behavior of AA2519-T8 Aluminum Alloy Under High Strain Rate Loading in Compression

    Science.gov (United States)

    Olasumboye, A. T.; Owolabi, G. M.; Odeshi, A. G.; Yilmaz, N.; Zeytinci, A.

    2018-02-01

    In this study, the effects of strain rate on the dynamic behavior, microstructure evolution and hence, failure of the AA2519-T8 aluminum alloy were investigated under compression at strain rates ranging from 1000 to 3500 s-1. Cylindrical specimens of dimensions 3.3 mm × 3.3 mm (L/D = 1) were tested using the split-Hopkinson pressure bar integrated with a digital image correlation system. The microstructure of the alloy was assessed using optical and scanning electron microscopes. Results showed that the dynamic yield strength of the alloy is strain rate dependent, with the maximum yield strength attained by the material being 500 MPa. The peak flow stress of 562 MPa was attained by the material at 3500 s-1. The alloy also showed a significant rate of strain hardening that is typical of other Al-Cu alloys; the rate of strain hardening, however, decreased with increase in strain rate. It was determined that the strain rate sensitivity coefficient of the alloy within the range of high strain rates used in this study is approximately 0.05 at 0.12 plastic strain; a more significant value than what was reported in literature under quasi-static loading. Micrographs obtained showed potential sites for the evolution of adiabatic shear band at 3500 s-1, with a characteristic circular-shaped surface profile comprising partially dissolved second phase particles in the continuous phase across the incident plane of the deformed specimen. The regions surrounding the site showed little or no change in the size of particles. However, the constituent coarse particles were observed as agglomerations of fractured pieces, thus having a shape factor different from those contained in the as-received alloy. Since the investigated alloy is a choice material for military application where it can be exposed to massive deformation at high strain rates, this study provides information on its microstructural and mechanical responses to such extreme loading condition.

  19. The effect of loading rate on pile bearing capacity of saturated sand

    NARCIS (Netherlands)

    Archeewa, E.

    2005-01-01

    Pile load tests are commonly used by engineers to determine its bearing capacity. At present, there are three methods of pile load tests: the static, the dynamic and the quasi-static test. The static pile load test is done by applying an axial load on the pile with a long duration. The dynamic and

  20. Effect of ventilation rate and board loading on formaldehyde concentration : a critical review of the literature

    Science.gov (United States)

    George E. Myers

    1984-01-01

    A critical literature review has been carried out on the influence of ventilation rate (N, hr.-1) and board loading (L, m2/m3) on steady state formaldehyde concentrations (Cs, ppm) resulting from particleboard and plywood emissions. Large differences exist among boards in the extent to which their formaldehyde concentrations change with N or L in laboratory chambers....

  1. Influence of loading rate and modes on infiltration of treated wastewater in soil-based constructed wetland.

    Science.gov (United States)

    Bisone, Sara; Gautier, Mathieu; Masson, Matthieu; Forquet, Nicolas

    2017-01-01

    Over the last 10 years soil-based constructed wetlands for discharge of treated wastewater (TWW) are commonly presented as a valuable option to provide tertiary treatment. The uncomplete knowledge in soil modifications and a lack of clear design practices laid the foundation of this work. The aim of this study was to determine optimal hydraulic loads and to observe the main critical parameters affecting treating performances and hydraulic loads acceptance. For this purpose, a soil rich in clay and backfill was chosen to perform column infiltration tests with TWW. Two loading rates and two loading modes were compared to study the influence of an intermittent feeding. Inlet and outlet waters were periodically analysed and columns were instrumented with balances, tensiometers, O 2 and temperature probes. Soil physico-chemical characteristics were also taken into account to better understand the modification of the soil. One of the main expectations of tertiary treatment is to improve phosphate removal. A particular attention was thus given to phosphorus retention. The interest of an intermittent feeding in presence of a soil with high clay content was showed. This study highlighted that an intermittent feeding could make possible the use of a clay-rich soil for water infiltration.

  2. Tradeoffs between impact loading rate, vertical impulse and effective mass for walkers and heel strike runners wearing footwear of varying stiffness.

    Science.gov (United States)

    Addison, Brian J; Lieberman, Daniel E

    2015-05-01

    Humans experience repetitive impact forces beneath the heel during walking and heel strike running that cause impact peaks characterized by high rates and magnitudes of loading. Impact peaks are caused by the exchange of momentum between the ground and a portion of the body that comes to a full stop (the effective mass) during the period of the impact peak. A number of factors can influence this exchange of momentum, including footwear stiffness. This study presents and tests an impulse-momentum model of impact mechanics which predicts that effective mass and vertical impulse is greater in walkers and heel strike runners wearing less stiff footwear. The model also predicts a tradeoff between impact loading rate and effective mass, and between impact loading rate and vertical impulse among individuals wearing footwear of varying stiffness. We tested this model using 19 human subjects walking and running in minimal footwear and in two experimental footpads. Subjects walked and ran on an instrumented treadmill and 3D kinematic data were collected. As predicted, both vertical impulse (walking: F(2,54)=52.0, p=2.6E-13; running: F(2,54)=25.2, p=1.8E-8) and effective mass (walking: F(2,54)=12.1, p=4.6E-5; running: F(2,54)=15.5, p=4.7E-6) increase in less stiff footwear. In addition, there is a significant inverse relationship between impact loading rate and vertical impulse (walking: r=-0.88, pfootwear heels influence injury risk during human walking and running. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Effect of increasing nitrobenzene loading rates on the performance of anaerobic migrating blanket reactor and sequential anaerobic migrating blanket reactor/completely stirred tank reactor system

    International Nuclear Information System (INIS)

    Kuscu, Ozlem Selcuk; Sponza, Delia Teresa

    2009-01-01

    A laboratory scale anaerobic migrating blanket reactor (AMBR) reactor was operated at nitrobenzene (NB) loading rates increasing from 3.33 to 66.67 g NB/m 3 day and at a constant hydraulic retention time (HRT) of 6 days to observe the effects of increasing NB concentrations on chemical oxygen demand (COD), NB removal efficiencies, bicarbonate alkalinity, volatile fatty acid (VFA) accumulation and methane gas percentage. Moreover, the effect of an aerobic completely stirred tank reactor (CSTR) reactor, following the anaerobic reactor, on treatment efficiencies was also investigated. Approximately 91-94% COD removal efficiencies were observed up to a NB loading rate of 30.00 g/m 3 day in the AMBR reactor. The COD removal efficiencies decreased from 91% to 85% at a NB loading rate of 66.67 g/m 3 day. NB removal efficiencies were approximately 100% at all NB loading rates. The maximum total gas, methane gas productions and methane percentage were found to be 4.1, 2.6 l/day and 59%, respectively, at a NB loading rate of 30.00 g/m 3 day. The optimum pH values were found to be between 7.2 and 8.4 for maximum methanogenesis. The total volatile fatty acid (TVFA) concentrations in the effluent were 110 and 70 mg/l in the first and second compartments at NB loading rates as high as 66.67 and 6.67 g/m 3 day, respectively, while they were measured as zero in the effluent of the AMBR reactor. In this study, from 180 mg/l NB 66 mg/l aniline was produced in the anaerobic reactor while aniline was completely removed and transformed to 2 mg/l of cathechol in the aerobic CSTR reactor. Overall COD removal efficiencies were found to be 95% and 99% for NB loading rates of 3.33 and 66.67 g/m 3 day in the sequential anaerobic AMBR/aerobic CSTR reactor system, respectively. The toxicity tests performed with Photobacterium phosphoreum (LCK 480, LUMIStox) and Daphnia magna showed that the toxicity decreased with anaerobic/aerobic sequential reactor system from the influent, anaerobic and to

  4. Estimativa de recarga da bacia do Rio das Fêmeas através de métodos manuais e automáticos Estimates of the recharge in the Femeas River basin by manual and automatic methods

    Directory of Open Access Journals (Sweden)

    Ana C. L. S. Albuquerque

    2011-11-01

    Full Text Available Na região do oeste baiano, na qual se encontra a bacia do Rio das Fêmeas, a água subterrânea tem sido progressivamente procurada como fonte de abastecimento, haja vista a baixa densidade de drenagem da região e a crescente demanda por água, sobremaneira para projetos de irrigação. O objetivo do presente estudo é, a partir de dados de vazão, calcular a recarga da água subterrânea por meio de duas metodologias: Arnold & Allen (1999 e Rutledge & Daniel (1994, para o período de 1977 a 2007. A precipitação média anual para a bacia do Rio das Fêmeas foi de 1121,83 mm ano-1 e a vazão média anual igual a 50,28 m³ s-1, ambas apresentando tendência de queda significativa ao longo dos anos. As taxas de recarga foram de 4% da P total (Arnold & Allen, 1999 e de 17% (Rutledge & Daniel, 1994. Com referência ao escoamento de base (aproximadamente 250 mm ano-1, o último método mostrou-se melhor na estimação da recarga.In Western Bahia, where the Fêmeas River Basin is located, groundwater has been increasingly utilized, given the low density of drainage in the region and the growing demand for water, mainly irrigation projects. The objectives of this study are based on flow data to calculate the recharge of groundwater in the Femeas basin using two methods: Arnold & Allen (1999 and Rutledge & Daniel (1994, in the period of 1977 to 2007. The mean annual precipitation in the Fêmeas River Basin in the studied period was 1121.83 mm year-1 and the mean stream flow was 50.28 m³ s-1 year-1. Both showed a significant decreasing trend over the years. The mean base flow found for the basin was 257.41 mm year-1. The rates of recharge were 4% of total P (Arnold & Allen, 1999, and 17% (Rutledge & Daniel, 1994. Considering the basin discharge (around 250 mm year-1, the latter method seems to be better in estimating recharge.

  5. Reconceptualizing perceptual load as a rate problem: The role of time in the allocation of selective attention.

    Science.gov (United States)

    Li, Zhi; Xin, Keyun; Li, Wei; Li, Yanzhe

    2018-04-30

    In the literature about allocation of selective attention, a widely studied question is when will attention be allocated to information that is clearly irrelevant to the task at hand. The present study, by using convergent evidence, demonstrated that there is a trade-off between quantity of information present in a display and the time allowed to process it. Specifically, whether or not there is interference from irrelevant distractors depends not only on the amount of information present, but also on the amount of time allowed to process that information. When processing time is calibrated to the amount of information present, irrelevant distractors can be selectively ignored successfully. These results suggest that the perceptual load in the load theory of selective attention (i.e., Lavie, 2005) should be thought about as a dynamic rate problem rather than a static capacity limitation. The authors thus propose that rather than conceiving of perceptual load as a quantity of information, they should consider it as a quantity of information per unit of time. In other words, it is the relationship between the quantity of information in the task and the time for processing the information that determines the allocation of selective attention. Thus, the present findings extended load theory, allowing it to explain findings that were previously considered as counter evidence of load theory. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  6. Experimental investigation of the failure envelope of unidirectional carbon-epoxy composite under high strain rate transverse and off-axis tensile loading

    Directory of Open Access Journals (Sweden)

    Kuhn Peter

    2015-01-01

    Full Text Available The mechanical response of the carbon-epoxy material system HexPly IM7-8552 was investigated under transverse tension and combined transverse tension / in-plane shear loading at quasi-static and dynamic strain rates. The dynamic tests of the transverse tension and off-axis tension specimens were carried out on a split-Hopkinson tension bar system, while the quasi-static reference tests were performed on a standard electro-mechanical testing machine. Digital image correlation was used for data reduction at both strain rate regimes. For the high rate tests, the strain rate in loading direction was adjusted to reach approximately the same strain rate value in the fracture plane for each specimen. The measured axial strengths were transformed from the global coordinate system into the combined transverse tension-shear stress space of the material coordinate system and compared with the Puck Mode A criterion for inter-fibre failure. A good correlation between the experimental data and the predicted failure envelopes was found for both investigated strain rate regimes.

  7. Changes in patellofemoral pain resulting from repetitive impact landings are associated with the magnitude and rate of patellofemoral joint loading.

    Science.gov (United States)

    Atkins, Lee T; James, C Roger; Yang, Hyung Suk; Sizer, Phillip S; Brismée, Jean-Michel; Sawyer, Steven F; Powers, Christopher M

    2018-03-01

    Although a relationship between elevated patellofemoral forces and pain has been proposed, it is unknown which joint loading variable (magnitude, rate) is best associated with pain changes. The purpose of this study was to examine associations among patellofemoral joint loading variables and changes in patellofemoral pain across repeated single limb landings. Thirty-one females (age: 23.5(2.8) year; height: 166.8(5.8) cm; mass: 59.6(8.1) kg) with PFP performed 5 landing trials from 0.25 m. The dependent variable was rate of change in pain obtained from self-reported pain scores following each trial. Independent variables included 5-trial averages of peak, time-integral, and average and maximum development rates of the patellofemoral joint reaction force obtained using a previously described model. Pearson correlation coefficients were calculated to evaluate individual associations between rate of change in pain and each independent variable (α = 0.05). Stepwise linear multiple regression (α enter  = 0.05; α exit  = 0.10) was used to identify the best predictor of rate of change in pain. Subjects reported an average increase of 0.38 pain points with each landing trial. Although, rate of change in pain was positively correlated with peak force (r = 0.44, p = 0.01), and average (r = 0.41, p = 0.02) and maximum force development rates (r = 0.39, p = 0.03), only the peak force entered the predictive model explaining 19% of variance in rate of change in pain (r 2  = 0.19, p = 0.01). Peak patellofemoral joint reaction force was the best predictor of the rate of change in pain following repetitive singe limb landings. The current study supports the theory that patellofemoral joint loading contributes to changes in patellofemoral pain. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Microbial Population Dynamics and Ecosystem Functions of Anoxic/Aerobic Granular Sludge in Sequencing Batch Reactors Operated at Different Organic Loading Rates

    Directory of Open Access Journals (Sweden)

    Enikö Szabó

    2017-05-01

    Full Text Available The granular sludge process is an effective, low-footprint alternative to conventional activated sludge wastewater treatment. The architecture of the microbial granules allows the co-existence of different functional groups, e.g., nitrifying and denitrifying communities, which permits compact reactor design. However, little is known about the factors influencing community assembly in granular sludge, such as the effects of reactor operation strategies and influent wastewater composition. Here, we analyze the development of the microbiomes in parallel laboratory-scale anoxic/aerobic granular sludge reactors operated at low (0.9 kg m-3d-1, moderate (1.9 kg m-3d-1 and high (3.7 kg m-3d-1 organic loading rates (OLRs and the same ammonium loading rate (0.2 kg NH4-N m-3d-1 for 84 days. Complete removal of organic carbon and ammonium was achieved in all three reactors after start-up, while the nitrogen removal (denitrification efficiency increased with the OLR: 0% at low, 38% at moderate, and 66% at high loading rate. The bacterial communities at different loading rates diverged rapidly after start-up and showed less than 50% similarity after 6 days, and below 40% similarity after 84 days. The three reactor microbiomes were dominated by different genera (mainly Meganema, Thauera, Paracoccus, and Zoogloea, but these genera have similar ecosystem functions of EPS production, denitrification and polyhydroxyalkanoate (PHA storage. Many less abundant but persistent taxa were also detected within these functional groups. The bacterial communities were functionally redundant irrespective of the loading rate applied. At steady-state reactor operation, the identity of the core community members was rather stable, but their relative abundances changed considerably over time. Furthermore, nitrifying bacteria were low in relative abundance and diversity in all reactors, despite their large contribution to nitrogen turnover. The results suggest that the OLR has

  9. Effects of Surface Inclination on the Vertical Loading Rates and Landing Pattern during the First Attempt of Barefoot Running in Habitual Shod Runners

    OpenAIRE

    An, W.; Rainbow, M. J.; Cheung, R. T. H.

    2015-01-01

    Barefoot running has been proposed to reduce vertical loading rates, which is a risk factor of running injuries. Most of the previous studies evaluated runners on level surfaces. This study examined the effect of surface inclination on vertical loading rates and landing pattern during the first attempt of barefoot running among habitual shod runners. Twenty habitual shod runners were asked to run on treadmill at 8.0?km/h at three inclination angles (0?; +10?; ?10?) with and without their usua...

  10. SDOF models for reinforced concrete beams under impulsive loads accounting for strain rate effects

    Energy Technology Data Exchange (ETDEWEB)

    Stochino, F., E-mail: fstochino@unica.it [Department of Civil and Environmental Engineering and Architecture, University of Cagliari, Via Marengo 2, 09123 Cagliari (Italy); Carta, G., E-mail: giorgio_carta@unica.it [Department of Mechanical, Chemical and Materials Engineering, University of Cagliari, Via Marengo 2, 09123 Cagliari (Italy)

    2014-09-15

    Highlights: • Flexural failure of reinforced concrete beams under blast and impact loads is studied. • Two single degree of freedom models are formulated to predict the beam response. • Strain rate effects are taken into account for both models. • The theoretical response obtained from each model is compared with experimental data. • The two models give a good estimation of the maximum deflection at collapse. - Abstract: In this paper, reinforced concrete beams subjected to blast and impact loads are examined. Two single degree of freedom models are proposed to predict the response of the beam. The first model (denoted as “energy model”) is developed from the law of energy balance and assumes that the deformed shape of the beam is represented by its first vibration mode. In the second model (named “dynamic model”), the dynamic behavior of the beam is simulated by a spring-mass oscillator. In both formulations, the strain rate dependencies of the constitutive properties of the beams are considered by varying the parameters of the models at each time step of the computation according to the values of the strain rates of the materials (i.e. concrete and reinforcing steels). The efficiency of each model is evaluated by comparing the theoretical results with experimental data found in literature. The comparison shows that the energy model gives a good estimation of the maximum deflection of the beam at collapse, defined as the attainment of the ultimate strain in concrete. On the other hand, the dynamic model generally provides a smaller value of the maximum displacement. However, both approaches yield reliable results, even though they are based on some approximations. Being also very simple to implement, they may serve as an useful tool in practical applications.

  11. A study on the strength of an armour-grade aluminum under high strain-rate loading

    Science.gov (United States)

    Appleby-Thomas, G. J.; Hazell, P. J.

    2010-06-01

    The aluminum alloy 5083 in tempers such as H32 and H131 is an established light-weight armour material. While its dynamic response under high strain-rates has been investigated elsewhere, little account of the effect of material orientation has been made. In addition, little information on its strength under such loadings is available in the literature. Here, both the longitudinal and lateral components of stress have been measured using embedded manganin stress gauges during plate-impact experiments on samples with the rolling direction aligned both orthogonal and parallel to the impact axis. The Hugoniot elastic limit, spall, and shear strengths were investigated for incident pressures in the range 1-8 GPa, providing an insight into the response of this alloy under shock loading. Further, the time dependence of lateral stress behind the shock front was investigated to give an indication of material response.

  12. Flow time analysis of load management late arrival discrete time queueing system with dual service rate using hypo geometrical distribution

    International Nuclear Information System (INIS)

    Shah, S.A.; Shah, W.; Shaikh, F.K.

    2012-01-01

    Flow time analysis is a powerful concept to analyze the flow time of any arriving customer in any system at any instant. A load management mechanism can be employed very effectively in any queueing system by utilizing a system which provides probability of dual service rate. In this paper, we develop and demonstrate the flow and service processes transition diagram to determine the flow time of a customer in a load management late arrival state dependent finite discrete time queueing system with dual service rate where customers are hypo geometrically distributed. We compute the probability mass function of each starting state and total probability mass function. The obtained analytical results are validated with simulation results for varying values of arrival and service probabilities. (author)

  13. Effect of orientation and loading rate on compression behavior of small-scale Mo pillars

    International Nuclear Information System (INIS)

    Schneider, A.S.; Clark, B.G.; Frick, C.P.; Gruber, P.A.; Arzt, E.

    2009-01-01

    Recently, much work has focused on the size effect in face centered cubic (fcc) structures, however few pillar studies have focused on body centered cubic (bcc) metals. This paper explores the role of bcc crystal structure on the size effect, through compression testing of [001] and [235] Molybdenum (Mo) small-scale pillars manufactured by focused ion beam (FIB). The pillar diameters ranged from 200 nm to 5 μm. Results show that the relationship between yield stress and diameter exhibits an inverse relationship (σ y ∝ d -0.22 for [001] Mo and σ y ∝ d -0.34 for [235] Mo) weaker than that observed for face centered cubic (fcc) metals (σ y ∝ d -0.6to-1.0 ). Additional tests at various loading rates revealed that small-scale Mo pillars exhibit a strain rate sensitivity similar to bulk Mo.

  14. Ductile fracture mechanism of low-temperature In-48Sn alloy joint under high strain rate loading.

    Science.gov (United States)

    Kim, Jong-Woong; Jung, Seung-Boo

    2012-04-01

    The failure behaviors of In-48Sn solder ball joints under various strain rate loadings were investigated with both experimental and finite element modeling study. The bonding force of In-48Sn solder on an Ni plated Cu pad increased with increasing shear speed, mainly due to the high strain-rate sensitivity of the solder alloy. In contrast to the cases of Sn-based Pb-free solder joints, the transition of the fracture mode from a ductile mode to a brittle mode was not observed in this solder joint system due to the soft nature of the In-48Sn alloy. This result is discussed in terms of the relationship between the strain-rate of the solder alloy, the work-hardening effect and the resulting stress concentration at the interfacial regions.

  15. Estimation of physical work load by statistical analysis of the heart rate in a conveyor-belt worker.

    Science.gov (United States)

    Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J

    1994-12-01

    Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.

  16. Dosimetric advancement of high-dose-rate after-loading 192Ir source

    International Nuclear Information System (INIS)

    Zhang Shuxu; Li Wenhua; Xu Hairong

    2004-01-01

    High-dose-rate (HDR) 192 Ir source is a nuclide commonly used in the brachytherapy system. The basic dosimetry data of the near source area is usually measured by pin ion chambers or TLD techniques, but these methods have a lower spatial resolution than Electron spin resonance (ESR) dosimetry which has a spatial resolution of 156 μm, and the Monte Carlo photon transport simulations are taken as the golden standard of those measures. The precision in two-dimensional dose distribution measured by GafChromic film is reported to be 1.0%. In vivo dosimetry using TLD during HDR intracavitary after-loading brachytherapy is a good predictor of late rectal complications. The accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry for three-dimensional dose distribution is about 2.5% with a spatial resolution of 1.56 mm. The optical computed tomography polymer gel dosimetry has a unique advance than MRI gel dosimetry

  17. Fuel cladding behavior under rapid loading conditions

    Science.gov (United States)

    Yueh, K.; Karlsson, J.; Stjärnsäter, J.; Schrire, D.; Ledergerber, G.; Munoz-Reja, C.; Hallstadius, L.

    2016-02-01

    A modified burst test (MBT) was used in an extensive test program to characterize fuel cladding failure behavior under rapid loading conditions. The MBT differs from a normal burst test with the use of a driver tube to simulate the expansion of a fuel pellet, thereby producing a partial strain driven deformation condition similar to that of a fuel pellet expansion in a reactivity insertion accident (RIA). A piston/cylinder assembly was used to pressurize the driver tube. By controlling the speed and distance the piston travels the loading rate and degree of sample deformation could be controlled. The use of a driver tube with a machined gauge section localizes deformation and allows for continuous monitoring of the test sample diameter change at the location of maximum hoop strain, during each test. Cladding samples from five irradiated fuel rods were tested between 296 and 553 K and loading rates from 1.5 to 3.5/s. The test rods included variations of Zircaloy-2 with different liners and ZIRLO, ranging in burn-up from 41 to 74 GWd/MTU. The test results show cladding ductility is strongly temperature and loading rate dependent. Zircaloy-2 cladding ductility degradation due to operational hydrogen pickup started to recover at approximately 358 K for test condition used in the study. This recovery temperature is strongly loading rate dependent. At 373 K, ductility recovery was small for loading rates less than 8 ms equivalent RIA pulse width, but longer than 8 ms the ductility recovery increased exponentially with increasing pulse width, consistent with literature observations of loading rate dependent brittle-to-ductile (BTD) transition temperature. The cladding ductility was also observed to be strongly loading rate/pulse width dependent for BWR cladding below the BTD temperature and Pressurized Water Reactor (PWR) cladding at both 296 and 553 K.

  18. Effect of trace element addition and increasing organic loading rates on the anaerobic digestion of cattle slaughterhouse wastewater.

    Science.gov (United States)

    Schmidt, Thomas; McCabe, Bernadette K; Harris, Peter W; Lee, Seonmi

    2018-05-18

    In this study, anaerobic digestion of slaughterhouse wastewater with the addition of trace elements was monitored for biogas quantity, quality and process stability using CSTR digesters operated at mesophilic temperature. The determination of trace element concentrations was shown to be deficient in Fe, Ni, Co, Mn and Mo compared to recommendations given in the literature. Addition of these trace elements resulted in enhanced degradation efficiency, higher biogas production and improved process stability. Higher organic loading rates and lower hydraulic retention times were achieved in comparison to the control digesters. A critical accumulation of volatile fatty acids was observed at an organic loading rate of 1.82 g L -1  d -1 in the control compared to 2.36 g L -1  d -1 in the digesters with trace element addition. The improved process stability was evident in the final weeks of experimentation, in which control reactors produced 84% less biogas per day compared to the reactors containing trace elements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Effect of loading rate on dynamic fracture of reaction bonded silicon nitride

    Science.gov (United States)

    Liaw, B. M.; Kobayashi, A. S.; Emery, A. F.

    1986-01-01

    Wedge-loaded, modified tapered double cantilever beam (WL-MTDCB) specimens under impact loading were used to determine the room temperature dynamic fracture response of reaction bonded silicon nitride (RBSN). The crack extension history, with the exception of the terminal phase, was similar to that obtained under static loading. Like its static counterpart, a distinct crack acceleration phase, which was not observed in dynamic fracture of steel and brittle polymers, was noted. Unlike its static counterpart, the crack continued to propagate at nearly its terminal velocity under a low dynamic stress intensity factor during the terminal phase of crack propagation. These and previously obtained results for glass and RBSN show that dynamic crack arrest under a positive dynamic stress intensity factor is unlikely in static and impact loaded structural ceramics.

  20. Strain rate dependent orthotropic properties of pristine and impulsively loaded porcine temporomandibular joint disk.

    Science.gov (United States)

    Beatty, M W; Bruno, M J; Iwasaki, L R; Nickel, J C

    2001-10-01

    The purpose of this study was to characterize the tensile stress-strain behavior of the porcine temporomandibular joint (TMJ) disk with respect to collagen orientation and strain rate dependency. The apparent elastic modulus, ultimate tensile strength, and strain at maximum stress were measured at three elongation rates (0.5, 50, and 500 mm/min) for dumbbell-shaped samples oriented along either anteroposterior or mediolateral axes of the disks. In order to study the effects of impact-induced fissuring on the mechanical behavior, the same properties were measured along each orientation at an elongation rate of 500 mm/min for disks subjected to impulsive loads of 0.5 N. s. The results suggested a strongly orthotropic nature to the healthy pristine disk. The values for the apparent modulus and ultimate strength were 10-fold higher along the anteroposterior axis (p disks for either orientation (p > 0.05). The results demonstrated the importance of choosing an orthotropic model for the TMJ disk to conduct finite element modeling, to develop failure criteria, and to construct tissue-engineered replacements. Impact-induced fissuring requires further study to determine if the TMJ disk is orthotropic with respect to fatigue.

  1. Formation of nitrous oxide in a gradient of oxygenation and nitrogen loading rate during denitrification of nitrite and nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Gong, You-Kui; Peng, Yong-Zhen [School of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022 (China); Yang, Qing, E-mail: gykren@163.com [School of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022 (China); Wu, Wei-Min [State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, 150090 (China); Wang, Shu-Ying [School of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022 (China)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The correlation of DO to N{sub 2}O emission under denitrification via nitrite was confirmed. Black-Right-Pointing-Pointer The higher nitrite ratio in NO{sub x} (nitrite and nitrate) caused the more N{sub 2}O emission. Black-Right-Pointing-Pointer Reactor feed mode and nitrite loading rate had significant impact on N{sub 2}O emission which was related to nitrite level. - Abstract: Nitrous oxide (N{sub 2}O) emission has been observed during denitrification of nitrate via nitrite as intermediate. With a laboratory-scale reactor (2.4 L), the N{sub 2}O emission was characterized under a gradient of DO concentration from 0 to 0.7 mg/L, different ratio of nitrite versus nitrate and different nitrite feed mode. The N{sub 2}O emission was influenced by the level of dissolved oxygen (DO) and nitrite accumulation. The higher DO level and the higher ratio of nitrite versus nitrate resulted in the higher N{sub 2}O emission. Using nitrite as sole electron acceptor at the same loading rate, the sequence of N{sub 2}O emission with three different feed modes was: pulse > step-wise > continuous feed. The N{sub 2}O emitted in pulse feed reactors was 3.1-4.2 and 8.2-11.7 folds of that in the step-wise feed and continuous feed reactors, respectively. With continuous feed mode, the impact of DO concentration on the mass of N{sub 2}O emitted was limited while the higher N{sub 2}O emission occurred at the higher nitrite loading rate.

  2. Fatigue life assessment of thin-walled welded joints under non-proportional load-time histories by the shear stress rate integral approach

    Directory of Open Access Journals (Sweden)

    A. Bolchoun

    2016-10-01

    Full Text Available Fatigue life tests under constant and variable amplitude loadings were performed on the tube-tube thin-walled welded specimens made of magnesium (AZ31 and AZ61 alloys. The tests included pure axial, pure torsional and combined in-phase and out-of-phase loadings with the load ratio  RR " ", " " 1  . For the tests with variable amplitude loads a Gaußdistributed loading spectrum with S L 4 5 10  cycles was used. Since magnesium welds show a fatigue life reduction under out-of-phase loads, a stress-based method, which takes this behavior into account, is proposed. The out-of-phase loading results in rotating shear stress vectors in the section planes, which are not orthogonal to the surface. This fact is used in order to provide an out-of-phase measure of the load. This measure is computed as an area covered by the shear stress vectors in all planes over a certain time interval, its computation involves the shear stress and the shear stress rate vectors in the individual planes. Fatigue life evaluation for the variable amplitudes loadings is performed using the Palmgren-Miner linear damage accumulation, whereas the total damage of every cycle is split up into two components: the amplitude component and the out-of-phase component. In order to compute the two components a modification of the rainflow counting method, which keeps track of the time intervals, where the cycles occur, must be used. The proposed method also takes into account different slopes of the pure axial and the pure torsional Wöhler-line by means of a Wöhler-line interpolation for combined loadings

  3. A software reconfigurable optical multiband UWB system utilizing a bit-loading combined with adaptive LDPC code rate scheme

    Science.gov (United States)

    He, Jing; Dai, Min; Chen, Qinghui; Deng, Rui; Xiang, Changqing; Chen, Lin

    2017-07-01

    In this paper, an effective bit-loading combined with adaptive LDPC code rate algorithm is proposed and investigated in software reconfigurable multiband UWB over fiber system. To compensate the power fading and chromatic dispersion for the high frequency of multiband OFDM UWB signal transmission over standard single mode fiber (SSMF), a Mach-Zehnder modulator (MZM) with negative chirp parameter is utilized. In addition, the negative power penalty of -1 dB for 128 QAM multiband OFDM UWB signal are measured at the hard-decision forward error correction (HD-FEC) limitation of 3.8 × 10-3 after 50 km SSMF transmission. The experimental results show that, compared to the fixed coding scheme with the code rate of 75%, the signal-to-noise (SNR) is improved by 2.79 dB for 128 QAM multiband OFDM UWB system after 100 km SSMF transmission using ALCR algorithm. Moreover, by employing bit-loading combined with ALCR algorithm, the bit error rate (BER) performance of system can be further promoted effectively. The simulation results present that, at the HD-FEC limitation, the value of Q factor is improved by 3.93 dB at the SNR of 19.5 dB over 100 km SSMF transmission, compared to the fixed modulation with uncoded scheme at the same spectrum efficiency (SE).

  4. Relationships between rating-of-perceived-exertion- and heart-rate-derived internal training load in professional soccer players: a comparison of on-field integrated training sessions.

    Science.gov (United States)

    Campos-Vazquez, Miguel Angel; Mendez-Villanueva, Alberto; Gonzalez-Jurado, Jose Antonio; León-Prados, Juan Antonio; Santalla, Alfredo; Suarez-Arrones, Luis

    2015-07-01

    To describe the internal training load (ITL) of common training sessions performed during a typical week and to determine the relationships between different indicators of ITL commonly employed in professional football (soccer). Session-rating-of-perceived-exertion TL (sRPE-TL) and heart-rate- (HR) derived measurements of ITL as Edwards TL and Stagno training impulses (TRIMPMOD) were used in 9 players during 3 periods of the season. The relationships between them were analyzed in different training sessions during a typical week: skill drills/circuit training + small-sided games (SCT+SSGs), ball-possession games+technical-tactical exercises (BPG+TTE), tactical training (TT), and prematch activation (PMa). HR values obtained during SCT+SSGs and BPG+TTE were substantially greater than those in the other 2 sessions, all the ITL markers and session duration were substantially greater in SCT+SSGs than in any other session, and all ITL measures in BPG+TTE were substantially greater than in TT and PMa sessions. Large relationships were found between HR>80% HRmax and HR>90% HRmax vs sRPE-TL during BPG+TTE and TT sessions (r=.61-.68). Very large relationships were found between Edwards TL and sRPE-TL and between TRIMPMOD and sRPE-TL in sessions with BPG+TTE and TT (r=.73-.87). Correlations between the different HR-based methods were always extremely large (r=.92-.98), and unclear correlations were observed for other relationships between variables. sRPE-TL provided variable-magnitude within-individual correlations with HR-derived measures of training intensity and load during different types of training sessions typically performed during a week in professional soccer. Caution should be applied when using RPE- or HR-derived measures of exercise intensity/load in soccer training interchangeably.

  5. Effects of Loading Rate on Gas Seepage and Temperature in Coal and Its Potential for Coal-Gas Disaster Early-Warning

    Directory of Open Access Journals (Sweden)

    Chong Zhang

    2017-08-01

    Full Text Available The seepage velocity and temperature externally manifest the changing structure, gas desorption and energy release that occurs in coal containing gas failure under loading. By using the system of coal containing gas failure under loading, this paper studies the law of seepage velocity and temperature under different loading rates and at 1.0 MPa confining pressure and 0.5 MPa gas pressure, and combined the on-site results of gas pressure and temperature. The results show that the stress directly affects the seepage velocity and temperature of coal containing gas, and the pressure and content of gas have the most sensitivity to mining stress. Although the temperature is not sensitive to mining stress, it has great correlation with mining stress. Seepage velocity has the characteristic of critically slowing down under loading. This is demonstrated by the variance increasing before the main failure of the samples. Therefore, the variance of seepage velocity with time and temperature can provide an early warning for coal containing gas failing and gas disasters in a coal mine.

  6. The High-Strain Rate Loading of Structural Biological Materials

    Science.gov (United States)

    Proud, W. G.; Nguyen, T.-T. N.; Bo, C.; Butler, B. J.; Boddy, R. L.; Williams, A.; Masouros, S.; Brown, K. A.

    2015-10-01

    The human body can be subjected to violent acceleration as a result of explosion caused by military ordinance or accident. Blast waves cause injury and blunt trauma can be produced by violent impact of objects against the human body. The long-term clinical manifestations of blast injury can be significantly different in nature and extent to those suffering less aggressive insult. Similarly, the damage seen in lower limbs from those injured in explosion incidents is in general more severe than those falling from height. These phenomena increase the need for knowledge of the short- and long-term effect of transient mechanical loading to the biological structures of the human body. This paper gives an overview of some of the results of collaborative investigation into blast injury. The requirement for time-resolved data, appropriate mechanical modeling, materials characterization and biological effects is presented. The use of a range of loading platforms, universal testing machines, drop weights, Hopkinson bars, and bespoke traumatic injury simulators are given.

  7. Assessing the performance of reinforced concrete structures under impact loads

    International Nuclear Information System (INIS)

    Sharma, Akanshu; Reddy, G.R.; Vaze, K.K.; Ozbolt, Josko; Hofmann, J.

    2011-01-01

    Reinforced concrete (RC) structures housing nuclear facilities must qualify against much stringent requirements of operating and accidental loads than conventional structures. One such accidental load that must be considered while assessing the performance of safety related RC structures is impact load. It is known that the behavior of concrete/reinforced concrete structures is strongly influenced by the loading rate. The RC structural members subjected to impact loads behave quite differently as compared to the same subjected to quasi-static loading due to the strain-rate influence on strength, stiffness, and ductility as well as to the activation of inertia forces. Moreover, for concrete structures, which exhibit damage and fracture phenomena, the failure mode and cracking pattern depend significantly on loading rate. In general, there is a tendency that with the increase of loading rate the failure mode changes from mode-I to mixed mode. In order to assess the performance of existing structures against impact loads that may be generated mainly due to man-made accidental conditions, it is important to have models that can realistically predict the impact behavior of concrete structures. The present paper focuses on a relatively new approach for 3D finite element analysis of RC structures under impact loads. The approach uses rate sensitive micro-plane model as constitutive law for concrete, while the strain-rate influence is captured by the activation energy. Inertia forces are implicitly accounted for through dynamic finite element analysis. It is shown with the help of different examples that the approach can very well simulate the behavior of RC structural elements under high rate loading. (author)

  8. Comparison between simplified load spectra in accordance with Germanische Lloyd guidelines, and load spectra derived from time domain simulations

    Energy Technology Data Exchange (ETDEWEB)

    Rees, M [Aerodyn Energiesysteme gmbH, Rendsburg (Germany)

    1996-09-01

    The Germanische Lloyd guideline allows calculations of load spectra in two fundamentally different ways. In the case of the so-called `simplified load spectra` the maximum amplitude of fluctuation of a load component is formed as {+-}75% of the average value of the purely aerodynamic loads of this component at rated wind conditions, together with an overlay of mass-related loads. The second method allowed in the GL guideline is the calculation of load spectra from simulation results in the time domain. For a number of average wind speeds the time-dependent characteristics of the load components are calculated taking account of the natural spatial turbulence of the wind. These are converted into load spectra using the rainflow method. In a parametric study the load spectra are calculated according to both methods and compared. The calculations are performed for turbines with rated powers of 100 kW to 2000 kW, with two and three blades, and also for stall-controlled and pitch-controlled turbines. The calculated load spectra are compared with each by means of 1 P fatigue equivalent load spectra. The influence of individual parameters is presented, as is the validity of the simplified load spectra. (au)

  9. Modeling of concrete exposed to severe loading conditions - impact and fire

    International Nuclear Information System (INIS)

    Ozbolt, J.; Periskic, G.; Bosnjak, J.; Reinhardt, H.W.; Sharma, A.; Travas, V.

    2011-01-01

    It is well known that the behavior of concrete structures is strongly influenced by loading rate. Compared to quasi-static loading, concrete loaded by impact loading acts in different ways. First, there is a strain-rate influence on strength, stiffness, and ductility, and second, there are inertia forces activated. Both influences are clearly demonstrated in experiments. Moreover, for concrete structures, which exhibit damage and fracture phenomena, the failure mode and cracking pattern depend on loading rate. In general, there is a tendency that with the increase of loading rate the failure mode changes from mode-I to mixed mode. Furthermore, theoretical and experimental investigations indicate that after the crack reaches critical speed of propagation there is crack branching. First part of the present paper focuses on 3D finite-element studies of concrete structures of different kind exposed to impact loading. In the numerical studies the rate sensitive microplane model is used as a constitutive law. The strain-rate influence is captured by the activation energy theory. Inertia forces are implicitly accounted for through dynamic finite element analysis. The results of the study show that the failure mode and structural resistance strongly depend on the loading rate

  10. Experimental investigation on load capacity and wear rate of ...

    African Journals Online (AJOL)

    In this study, a boundary condition test was conducted on journal bearing materials (Al-Tin alloy and Lead-Bronze alloy) used in Peugeot and Toyota automobiles were examined at room temperature conditions. The results of experiments are presented in graphics which proves that the average loading capacities, PV factor ...

  11. Benthic Uptake Rate due to Hyporheic Exchange: The Effects of Streambed Morphology for Constant and Sinusoidally Varying Nutrient Loads

    Directory of Open Access Journals (Sweden)

    Daniele Tonina

    2015-01-01

    Full Text Available Hyporheic exchange carries reactive solutes, which may include biological oxygen demand (BOD, dissolved oxygen (DO and reactive dissolved inorganic nitrogen (Nr, into the sediment, where biochemical reactions consume DO. Here, we study the impact of streambed morphology, stream-reactive solute loads and their diel oscillations on the DO benthic uptake rate (BUR due to hyporheic processes. Our model solves the hyporheic flow field and the solute transport equations analytically, within a Lagrangian framework, considering advection, longitudinal diffusion and reactions modeled as first order kinetics. The application of the model to DO field measurements over a gravel bar-pool sequence shows a good match with measured DO concentrations with an overall agreement of 58% and a kappa index of 0.46. We apply the model to investigate the effects of daily constant and sinusoidally time varying stream BOD, DO and Nr loads and of the morphodynamic parameters on BUR. Our modeling results show that BUR varies as a function of bedform size and of nutrient loads and that the hyporheic zone may consume up to 0.06% of the stream DO at the pool-riffle bedform scale. Daily oscillations of stream BOD and DO loads have small effects on BUR, but may have an important influence on local hyporheic processes and organisms’ distribution.

  12. Simultaneous optimization of the cavity heat load and trip rates in linacs using a genetic algorithm

    Directory of Open Access Journals (Sweden)

    Balša Terzić

    2014-10-01

    Full Text Available In this paper, a genetic algorithm-based optimization is used to simultaneously minimize two competing objectives guiding the operation of the Jefferson Lab’s Continuous Electron Beam Accelerator Facility linacs: cavity heat load and radio frequency cavity trip rates. The results represent a significant improvement to the standard linac energy management tool and thereby could lead to a more efficient Continuous Electron Beam Accelerator Facility configuration. This study also serves as a proof of principle of how a genetic algorithm can be used for optimizing other linac-based machines.

  13. Optimization of the RF cavity heat load and trip rates for CEBAF at 12 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, He [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Roblin, Yves R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Freyberger, Arne P. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Krafft, Geoffrey A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Terzic, Balsa P. [Old Dominion Univ., Norfolk, VA (United States)

    2017-05-01

    The Continuous Electron Beam Accelerator Facility at JLab has 200 RF cavities in the north linac and the south linac respectively after the 12 GeV upgrade. The purpose of this work is to simultaneously optimize the heat load and the trip rate for the cavities and to reconstruct the pareto-optimal front in a timely manner when some of the cavities are turned down. By choosing an efficient optimizer and strategically creating the initial gradients, the pareto-optimal front for no more than 15 cavities down can be re-established within 20 seconds.

  14. Loading capacities and failure modes of various reinforced concrete slabs subjected to high-speed loading

    International Nuclear Information System (INIS)

    Saito, H.; Imamura, A.; Takeuchi, M.; Okamoto, S.; Kasai, Y.; Tsubota, H.; Yoshimura, M.

    1993-01-01

    The objective of this study was to clarify experimentally and analytically the loading capacities, deformations and failure modes of various types of reinforced concrete structures subjected to loads applied at various loading rates. Flat slabs, slabs with beams and cylindrical walls were tested under static, low-speed and high-speed loading. Analysis was applied to estimate the test results by the finite element method using a layered shell element. The analysis closely simulated the experimental results until punching shear failure occurred. (author)

  15. Cognitive Load of Learner Control: Extraneous or Germane Load?

    Directory of Open Access Journals (Sweden)

    Mieke Vandewaetere

    2013-01-01

    Full Text Available Computer-based learning environments become more tailored when learners can exert control over one or more parts of the learning process. Learner control (LC demands additional efforts of learners because, in addition to learning, they also have to monitor that learning. As a consequence, LC may cause additional cognitive load and even cognitive overload. The central question in this study is what type of cognitive load is induced by LC and whether the experienced load is related to learning outcomes. For this study, half of the students had control over task selection, while the other half had not. Within each condition, students were assigned to a single treatment, with the primary task to solely focus on the learning content, and a dual treatment, comprising a primary task and a secondary task. The results indicate that LC did not impose higher cognitive load as measured by secondary task scores and mental effort ratings.

  16. Measuring Load on Working Memory: The Use of Heart Rate as a Means of Measuring Chemistry Students' Cognitive Load

    Science.gov (United States)

    Cranford, Kristen N.; Tiettmeyer, Jessica M.; Chuprinko, Bryan C.; Jordan, Sophia; Grove, Nathaniel P.

    2014-01-01

    Information processing provides a powerful model for understanding how learning occurs and highlights the important role that cognitive load plays in this process. In instances in which the cognitive load of a problem exceeds the available working memory, learning can be seriously hindered. Previously reported methods for measuring cognitive load…

  17. Fitness-related differences in the rate of whole-body evaporative heat loss in exercising men are heat-load dependent.

    Science.gov (United States)

    Lamarche, Dallon T; Notley, Sean R; Louie, Jeffrey C; Poirier, Martin P; Kenny, Glen P

    2018-01-01

    What is the central question of this study? Aerobic fitness modulates heat loss, but the heat-load threshold at which fitness-related differences in heat loss occur in young healthy men remains unclear. What is the main finding and its importance? We demonstrate using direct calorimetry that aerobic fitness modulates heat loss in a heat-load-dependent manner, with fitness-related differences occurring between young men who have low and high fitness when the heat load is ∼≥500 W. Although aerobic fitness has been known for some time to modulate heat loss, our findings define the precise heat-load threshold at which fitness-related differences occur. The effect of aerobic fitness (defined as rate of peak oxygen consumption) on heat loss during exercise is thought to be related to the level of heat stress. However, it remains unclear at what combined exercise and environmental (net) heat-load threshold these fitness-related differences occur. To identify this, we assessed whole-body heat exchange (dry and evaporative) by direct calorimetry in young (22 ± 3 years) men matched for physical characteristics with low (Low-fit; 39.8 ± 2.5 ml O 2  kg -1  min -1 ), moderate (Mod-fit; 50.9 ± 1.2 ml O 2  kg -1  min -1 ) and high aerobic fitness (High-fit; 62.0 ± 4.4 ml O 2  kg -1  min -1 ; each n = 8), during three 30 min bouts of cycling in dry heat (40°C, 12% relative humidity) at increasing rates of metabolic heat production of 300 (Ex1), 400 (Ex2) and 500 W (Ex3), each followed by a 15 min recovery period. Each group was exposed to a similar net heat load (metabolic plus ∼100 W dry heat gain; P = 0.83) during each exercise bout [∼400 (Ex1), ∼500 (Ex2) and ∼600 W (Ex3); P fit (Ex2, 466 ± 21 W; Ex3, 557 ± 26 W) compared with the Low-fit group (Ex2, 439 ± 22 W; Ex3, 511 ± 20 W) during Ex2 and Ex3 (P ≤ 0.03). Conversely, evaporative heat loss for the Mod-fit group did not differ from either the High-fit or Low

  18. Short term load forecasting of anomalous load using hybrid soft computing methods

    Science.gov (United States)

    Rasyid, S. A.; Abdullah, A. G.; Mulyadi, Y.

    2016-04-01

    Load forecast accuracy will have an impact on the generation cost is more economical. The use of electrical energy by consumers on holiday, show the tendency of the load patterns are not identical, it is different from the pattern of the load on a normal day. It is then defined as a anomalous load. In this paper, the method of hybrid ANN-Particle Swarm proposed to improve the accuracy of anomalous load forecasting that often occur on holidays. The proposed methodology has been used to forecast the half-hourly electricity demand for power systems in the Indonesia National Electricity Market in West Java region. Experiments were conducted by testing various of learning rate and learning data input. Performance of this methodology will be validated with real data from the national of electricity company. The result of observations show that the proposed formula is very effective to short-term load forecasting in the case of anomalous load. Hybrid ANN-Swarm Particle relatively simple and easy as a analysis tool by engineers.

  19. Study of the effect of political measures on the citizen participation rate in recycling and on the environmental load reduction

    International Nuclear Information System (INIS)

    Matsui, Yasuhiro; Tanaka, Masaru; Ohsako, Masahiro

    2007-01-01

    Obtaining the cooperation of citizens to participate in separate waste collection is essential to create a recycling-oriented society. In this research, the degree of change in the citizen participation rate, which occurs when the contents of political measures such as the raising of awareness, provision of information, and the conditions of collection services were changed, was estimated together with the effect on the reduction in environmental load. A questionnaire survey was conducted, targeted at residents of Itabashi Ward, while logistic regression analyses were also conducted to create predictive models for recycling behavior, and sensitivity analyses of the models were carried out to estimate the increase in citizen participation rate achievable through the implementation of various political measures. It was found that the effect of 'thorough perception of information' was the largest, followed by 'minimization of evaluation of trouble' and 'thorough perception of efficacy of measures.' The effect of the improvement in the citizen participation rate on the reduction in environmental load was also evaluated quantitatively by life cycle inventory analyses. It was indicated that 'maximization of perception of information' had the greatest effect. However, the reduction effect with 'paper packs' and 'PET bottles' was relatively small compared with that of 'bottles/cans.'

  20. A Workflow to Model Microbial Loadings in Watersheds

    Science.gov (United States)

    Many watershed models simulate overland and instream microbial fate and transport, but few actually provide loading rates on land surfaces and point sources to the water body network. This paper describes the underlying general equations for microbial loading rates associated wit...

  1. The Effect of Soldier Marching, Rucksack Load, and Heart Rate on Marksmanship

    Science.gov (United States)

    2017-04-01

    has demonstrated that marksmanship is a complex task that can be modified by both physiological and psychological processes (Helin, Sihvonen...complete the march with Rucksack load due to an ankle injury sustained on the cross-country march, and par- tial data from his Rucksack visit was...that carrying heavier loads results in physiologic changes. A multilevel logistic regression controlling for the multiple observations (shots

  2. Enhancement of glomerular filtration rate and renal plasma flow by oral glucose load in well controlled insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Sandahl Christiansen, J; Christensen, C K; Hermansen, K

    1986-01-01

    Glomerular filtration rate (GFR) and renal plasma flow (RPF) were measured in 27 patients with uncomplicated insulin-dependent diabetes (IDDM) before and after an oral glucose load of 1.1 g glucose/kg body wt. In the 18 patients showing near-normoglycaemia (blood glucose less than or equal to 8....... No changes in blood pressure or urinary albumin excretion rates took place in either group. The reduction in plasma protein and in plasma growth hormone concentration were similar in the two groups. No change was seen in plasma arginine vasopressin concentration. There was no difference in the qualitative...

  3. Power transformer additional load losses separation procedure

    Directory of Open Access Journals (Sweden)

    Kostić Miloje M.

    2011-01-01

    Full Text Available The proposed procedure is based on the fact that total transformer losses (PLL1,n, determined by short circuit test, can be separated into two components: the eddy current losses in the windings (PEC1,n and stray flux losses (PSL1,n in iron parts of construction as well as in the transformer tank walls. The total additional load losses, PLLd1 and PLLdh, are determined by short circuit test results, conducted at rated frequency (f1 and at increased harmonic frequency (fh=h*f1. Using so obtained total additional load losses, PLLd1 and PLLdh, which can be expressed in the form PLLdh=PEC1,n*h2 + PSL1,n*h, the corresponding rate additional load losses values PEC1,n and PSL1,n are derived. At the end, for given load with predefined high harmonics content, (Ih/I1n, relative to rated current, the total additional load losses value ΣPLLdh > PLLd1, is found. In such a way all harmonics up to hmax are taken into account.

  4. Study on Mechanical Properties of Barite Concrete under Impact Load

    Science.gov (United States)

    Chen, Z. F.; Cheng, K.; Wu, D.; Gan, Y. C.; Tao, Q. W.

    2018-03-01

    In order to research the mechanical properties of Barite concrete under impact load, a group of concrete compression tests was carried out under the impact load by using the drop test machine. A high-speed camera was used to record the failure process of the specimen during the impact process. The test results show that:with the increase of drop height, the loading rate, the peak load, the strain under peak load, the strain rate and the dynamic increase factor (DIF) all increase gradually. The ultimate tensile strain is close to each other, and the time of impact force decreases significantly, showing significant strain rate effect.

  5. Loads and loads and loads: The influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Directory of Open Access Journals (Sweden)

    Beat eMeier

    2015-06-01

    Full Text Available In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load can affect prospective memory performance. The existence of multiple target events increases prospective load and adding complexity to the to-be-remembered action increases retrospective load. In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of prospective load on costs in the ongoing task for categorical targets (Experiment 2, but not for specific targets (Experiment 1. Retrospective load and ongoing task load both affected remembering the retrospective component of the prospective memory task. We suggest that prospective load can enhance costs in the ongoing task due to additional monitoring requirements. Retrospective load and ongoing task load seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  6. Pilot-scale anaerobic co-digestion of municipal biomass waste and waste activated sludge in China: Effect of organic loading rate

    International Nuclear Information System (INIS)

    Liu Xiao; Wang Wei; Shi Yunchun; Zheng Lei; Gao Xingbao; Qiao Wei; Zhou Yingjun

    2012-01-01

    Highlights: ► Co-digestion of municipal biomass waste (MBW) and waste activated sludge (WAS) was examined on a pilot-scale reactor. ► System performance and stability under OLR of 1.2, 2.4, 3.6, 4.8, 6.0 and 8.0 kg VS (m 3 d) −1 were analyzed. ► A maximum methane production rate of 2.94 m 3 (m 3 d) −1 was achieved at OLR of 8.0 kg VS (m 3 d) −1 and HRT of 15d. ► With the increasing OLRs, pH values, VS removal rate and methane concentration decreased and VFA increased. ► The changing of biogas production rate can be a practical approach to monitor and control anaerobic digestion system. - Abstract: The effects of organic loading rate on the performance and stability of anaerobic co-digestion of municipal biomass waste (MBW) and waste activated sludge (WAS) were investigated on a pilot-scale reactor. The results showed that stable operation was achieved with organic loading rates (OLR) of 1.2–8.0 kg volatile solid (VS) (m 3 d) −1 , with VS reduction rates of 61.7–69.9%, and volumetric biogas production of 0.89–5.28 m 3 (m 3 d) −1 . A maximum methane production rate of 2.94 m 3 (m 3 d) −1 was achieved at OLR of 8.0 kg VS (m 3 d) −1 and hydraulic retention time of 15 days. With increasing OLRs, the anaerobic reactor showed a decrease in VS removal rate, average pH value and methane concentration, and a increase of volatile fatty acid concentration. By monitoring the biogas production rate (BPR), the anaerobic digestion system has a higher acidification risk under an OLR of 8.0 kg VS (m 3 d) −1 . This result remarks the possibility of relating bioreactor performance with BPR in order to better understand and monitor anaerobic digestion process.

  7. In Situ Test Study of Characteristics of Coal Mining Dynamic Load

    Directory of Open Access Journals (Sweden)

    Jiang He

    2015-01-01

    Full Text Available Combination of coal mining dynamic load and high static stress can easily induce such dynamic disasters as rock burst, coal and gas outburst, roof fall, and water inrush. In order to obtain the characteristic parameters of mining dynamic load and dynamic mechanism of coal and rock, the stress wave theory is applied to derive the relation of mining dynamic load strain rate and stress wave parameters. The in situ test was applied to study the stress wave propagation law of coal mine dynamic load by using the SOS microseismic monitoring system. An evaluation method for mining dynamic load strain rate was proposed, and the statistical evaluation was carried out for the range of strain rate. The research results show that the loading strain rate of mining dynamic load is in direct proportion to the seismic frequency of coal-rock mass and particle peak vibration velocity and is in inverse proportion to wave velocity. The high-frequency component damps faster than the low-frequency component in the shockwave propagating process; and the peak particle vibration velocity has a power functional relationship with the transmitting distance. The loading strain rate of mining dynamic load is generally less than class 10−1/s.

  8. Cardiorespiratory interactions during resistive load breathing.

    Science.gov (United States)

    Calabrese, P; Perrault, H; Dinh, T P; Eberhard, A; Benchetrit, G

    2000-12-01

    The addition to the respiratory system of a resistive load results in breathing pattern changes and in negative intrathoracic pressure increases. The aim of this study was to use resistive load breathing as a stimulus to the cardiorespiratory interaction and to examine the extent of the changes in heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) in relation to the breathing pattern changes. HRV and RSA were studied in seven healthy subjects where four resistive loads were applied in a random order during the breath and 8-min recording made in each condition. The HRV spectral power components were computed from the R-R interval sequences, and the RSA amplitude and phase were computed from the sinusoid fitting the instantaneous heart rate within each breath. Adding resistive loads resulted in 1) increasing respiratory period, 2) unchanging heart rate, and 3) increasing HRV and changing RSA characteristics. HRV and RSA characteristics are linearly correlated to the respiratory period. These modifications appear to be linked to load-induced changes in the respiratory period in each individual, because HRV and RSA characteristics are similar at a respiratory period obtained either by loading or by imposed frequency breathing. The present results are discussed with regard to the importance of the breathing cycle duration in these cardiorespiratory interactions, suggesting that these interactions may depend on the time necessary for activation and dissipation of neurotransmitters involved in RSA.

  9. Wrist loading patterns during pommel horse exercises.

    Science.gov (United States)

    Markolf, K L; Shapiro, M S; Mandelbaum, B R; Teurlings, L

    1990-01-01

    Gymnastics is a sport which involves substantial periods of upper extremity support as well as frequent impacts to the wrist. Not surprisingly, wrist pain is a common finding in gymnasts. Of all events, the pommel horse is the most painful. In order to study the forces of wrist impact, a standard pommel horse was instrumented with a specially designed load cell to record the resultant force of the hand on the pommel during a series of basic skills performed by a group of seventeen elite male gymnasts. The highest mean peak forces were recorded during the front scissors and flair exercises (1.5 BW) with peaks of up to 2.0 BW for some gymnasts. The mean peak force for hip circles at the center or end of the horse was 1.1 BW. The mean overall loading rate (initial contact to first loading peak) ranged from 5.2 BWs-1 (hip circles) to 10.6 BW s-1 (flairs). However, many recordings displayed localized initial loading spikes which occurred during 'hard' landings on the pommel. When front scissors were performed in an aggressive manner, the initial loading spikes averaged 1.0 BW in magnitude (maximum 1.8 BW) with an average rise time of 8.2 ms; calculated localized loading rates averaged 129 BW s-1 (maximum 219 BW s-1). These loading parameters are comparable to those encountered at heel strike during running. These impact forces and loading rates are remarkably high for an upper extremity joint not normally exposed to weight-bearing loads, and may contribute to the pathogenesis of wrist injuries in gymnastics.

  10. Loading rate effects on strength and fracture toughness of pipe steels used in Task 1 of the IPIRG program

    International Nuclear Information System (INIS)

    Marschall, C.W.; Landow, M.P.; Wilkowski, G.M.

    1993-10-01

    Material characterization tests were conducted on laboratory specimens machined from pipes to determine the effect of dynamic loading (i.e., rates comparable to those for high amplitude seismic events) on tensile properties and fracture resistance at 288 C (550 F). Specimens were fabricated from seven different pipes, including carbon steels and stainless steels (both base metal and weld metal), which were to be subjected to full-scale pipe tests in IPIRG Task 1.0. For the stainless steels tested at 288 C (550 F), tensile strength was unchanged, while yield strength and fracture resistance were increased. The increase in fracture resistance was modest for the wrought base metals and substantial for the weld metal and the cast base metal. The carbon steels tested were sensitive to dynamic strain aging, and hence the strength and toughness was affected by both temperature and strain rate effects. The carbon steel base metal and welds exhibited ultimate tensile strength values at 288 C (550 F) that were greater than at room temperature. Furthermore, the ultimate tensile strength at 288 C (550 F) was lowered significantly by increased strain rate and, in the carbon steel base metals, increased strain rate also lowered the fracture resistance, substantially in the base metal of one pipe. In comparing these results to the IPIRG pipe test results to date, it was found that the trends of these tests agree well with the Subtask 1.2 quasi-static and dynamic pipe fracture experiments. Loads measured in the Subtask 1.1 pipe experiments were, however, somewhat higher than would have been expected by the trends observed in the laboratory tests

  11. A combined loading system integrated with portable winch and polyethylene chutes for loading of timber products

    Directory of Open Access Journals (Sweden)

    H. Hulusi Acar

    2016-01-01

    Full Text Available Truck loading operation is an important task during timber production operations in forestry. In Turkey, approximately 50 million timbers/logs are being produced per year, and then they are loaded into the logging trucks. The timber/logs are transported over the forest roads with an average of one million roundtrips. However, the traditional loading methods using manpower are mostly performed while some part is done by using loading machines which can be very costly and risky. This study aims developing a combined loading system in which heavy logs are loaded into logging trucks by pulling them by a log-line powered by a portable crane within the chute system. The slope of the log-line from ground to logging truck varied between 1% and 25%. Within the each work cycle of loading operation, only one log was loaded by pulling with portable crane. The average loading time was found as 161.8 seconds per cycle, in which 67% of the time was spent on pulling the log into the logging truck. The results indicated that the average pulling speed with crane power was 840.4 m/hr and productivity was calculated as 4.94 m3/hr. The result on system speed and productivity indicated close relations with results from previous studies. The hydraulic grapple loader or cranes are widely used and common loading machines, but they cannot be efficiently used in forestry operations, especially ones having a low timber productivity rate or having low economic value timber. In these conditions, loading methods that are cost efficient and do not require higher production rate should be employed. Therefore, a combined loading system introduced in this study can be a feasible solution for loading operations in those cases. Furthermore, it is believed that this loading system integrated with a portable crane can be cost efficient and time saving solution, as well as ergonomic and safe method in the field.

  12. Control of the flow rate in decreasing of the water load of peat production

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The retention capacity and control of the flow rate was studied in the Aqua-Peat research. The sedimentation ability of solid matter (peat particles), erosion, migration of the solid matter, and the functioning of the retention pipes located in the strip ditches and the sedimentation basins were measured in the research. Detection was also supplemented by laboratory scale models and by measurements made using them. A model, describing the solid matter erosion and migration on the mire, was compiled on the basis of the results. Migration of the solid matter is possible to reduce by pounding the water into the ditching. So there is more time for particles to settle before migration into watercources. By this method it is possible to reduce the solid matter loads caused by heavy rains and power-flows even by 88 %. If the flow control system is equipped with retainers and settling basins, the solid matter retention capacity can rise up to 93-97 %. The results have shown that the retention pipe retainers play more important role in reduction of solid matter load than sedimentation basins. A follow-up study was made using several types of retainers. A 5 cm thick siphon pipe appeared to be the best. The final selection of the retention pipes has, however, to be made as a compromise between the functioning of the drying process, production possibilities and solid matter retention. (1 ref., 2 figs.)

  13. Evaluation of rapid methods for in-situ characterization of organic contaminant load and biodegradation rates in winery wastewater.

    Science.gov (United States)

    Carvallo, M J; Vargas, I; Vega, A; Pizarro, G; Pizarr, G; Pastén, P

    2007-01-01

    Rapid methods for the in-situ evaluation of the organic load have recently been developed and successfully implemented in municipal wastewater treatment systems. Their direct application to winery wastewater treatment is questionable due to substantial differences between municipal and winery wastewater. We critically evaluate the use of UV-VIS spectrometry, buffer capacity testing (BCT), and respirometry as rapid methods to determine organic load and biodegradation rates of winery wastewater. We tested three types of samples: actual and treated winery wastewater, synthetic winery wastewater, and samples from a biological batch reactor. Not surprisingly, respirometry gave a good estimation of biodegradation rates for substrate of different complexities, whereas UV-VIS and BCT did not provide a quantitative measure of the easily degradable sugars and ethanol, typically the main components of the COD in the influent. However, our results strongly suggest that UV-VIS and BCT can be used to identify and estimate the concentration of complex substrates in the influent and soluble microbial products (SMP) in biological reactors and their effluent. Furthermore, the integration of UV-VIS spectrometry, BCT, and mathematical modeling was able to differentiate between the two components of SMPs: substrate utilization associated products (UAP) and biomass associated products (BAP). Since the effluent COD in biologically treated wastewaters is composed primarily by SMPs, the quantitative information given by these techniques may be used for plant control and optimization.

  14. Response of Jupiter's Aurora to Plasma Mass Loading Rate Monitored by the Hisaki Satellite During Volcanic Eruptions at Io

    Science.gov (United States)

    Kimura, T.; Hiraki, Y.; Tao, C.; Tsuchiya, F.; Delamere, P. A.; Yoshioka, K.; Murakami, G.; Yamazaki, A.; Kita, H.; Badman, S. V.; Fukazawa, K.; Yoshikawa, I.; Fujimoto, M.

    2018-03-01

    The production and transport of plasma mass are essential processes in the dynamics of planetary magnetospheres. At Jupiter, it is hypothesized that Io's volcanic plasma carried out of the plasma torus is transported radially outward in the rotating magnetosphere and is recurrently ejected as plasmoid via tail reconnection. The plasmoid ejection is likely associated with particle energization, radial plasma flow, and transient auroral emissions. However, it has not been demonstrated that plasmoid ejection is sensitive to mass loading because of the lack of simultaneous observations of both processes. We report the response of plasmoid ejection to mass loading during large volcanic eruptions at Io in 2015. Response of the transient aurora to the mass loading rate was investigated based on a combination of Hisaki satellite monitoring and a newly developed analytic model. We found that the transient aurora frequently recurred at a 2-6 day period in response to a mass loading increase from 0.3 to 0.5 t/s. In general, the recurrence of the transient aurora was not significantly correlated with the solar wind, although there was an exceptional event with a maximum emission power of 10 TW after the solar wind shock arrival. The recurrence of plasmoid ejection requires the precondition that an amount comparable to the total mass of magnetosphere, 1.5 Mt, is accumulated in the magnetosphere. A plasmoid mass of more than 0.1 Mt is necessary in case that the plasmoid ejection is the only process for mass release.

  15. Bucket foundations under lateral cyclic loading

    DEFF Research Database (Denmark)

    Foglia, Aligi

    failure envelopes. A jacked installation test is successfully compared with existing models. Tests of bucket foundations under lateral loading applied at different loading rates are analysed. As expected, the bearing capacity of bucket foundations under transient lateral loading increases dramatically...... documents on bearing capacity and installation of bucket foundations are reviewed and the results from the models found in literature are compared to the experimental results obtained in the current study. Monotonic tests of bucket foundations under lateral loading until failure are compared with existing...

  16. Unstable well behaviour in gas well liquid loading

    NARCIS (Netherlands)

    Belfroid, S.P.C.; Wijhe, A. van

    2017-01-01

    Liquid loading is the mechanism that is associated with increased liquid hold-up and liquid back flow at lower gas flow rates in gas production wells. In laboratory, most liquid loading experiments are performed at fixed gas and liquid rates (mass flow controlled). In the field, the well behavior is

  17. Current status of and problems in ice heat storage systems contributing to improving load rates. Strengthening works intended for leveling the electric power load; Fukaritsu kaizen ni kokensuru kori chikunetsu system no genjo to kadai. Denryoku fuka heikinka ni muketa torikumi no kyoka

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, T. [Agency of Natural Resources and Energy, Tokyo (Japan)

    1998-02-01

    This paper introduces improvement in annual load rate in power supply in Japan, and the measures to proliferate and expand the use of ice heat storage systems. The annual load rate in power supply has dropped to about 55% today from the level of about 70% in 1965. This has been caused by the following reasons: the maximum power demand having become sharper in summer due to rapid increase in demand for air conditioning for room cooling, increase in weight of business operation department associated with progress of service economy, and change in the industrial structure from the material type industry to the processing and assembling type industry in the industrial department. In order to achieve load shift in the room cooling demand, which accounts largely for consumer demand during the peak time in summer, and is the main cause for reduced load rate, it is important that a heat storage type air conditioning system and a gas room cooling system be used more widely. The heat storage air conditioning and gas room cooling systems have a bottleneck in their proliferation that their facility cost is more expensive than existing air conditioning systems of non-heat regeneration type. It is necessary to review legal institutions and electric power charge systems for the purpose of proliferation and expanded use of the heat regeneration air conditioning and gas room cooling systems. 2 figs.

  18. Corrosion Fatigue Crack Propagation Rate Characteristics for Weldable Ship and Offshore Steels with Regard to the Influence of Loading Frequency and Saltwater Temperature

    Directory of Open Access Journals (Sweden)

    Jakubowski Marek

    2017-03-01

    Full Text Available After Vosikovsky (1975, the corrosion fatigue crack growth rate (CFCGR characteristics have been divided into three regions. The region-III rates are very close to mechanical fatigue crack growth rates. CFCGR formulae, including the long-crack length effect (in region I only, the loading frequency effect (in region II only, and the saltwater temperature effect, have been proposed. It has been assumed that CFCGR is proportional to f-k, where f is the loading frequency and k is a constant. The averaged k-value for all steels of yield stress (YS below 500 MPa, usually with ferrite-pearlite microstructures, is higher than that for YS > 500 MPa, usually with quenched and tempered microstructures. The temperature effect does not appear in region I below room temperature. In the remaining cases, that is, in region I for elevated temperatures and in region II for both low and elevated temperatures, the CFCGR increases with increasing temperature. Under a potential of -0.8 V, a long-crack-length effect, qualitatively similar to analogous effect for free corrosion conditions, appears.

  19. A Workflow to Model Microbial Loadings in Watersheds (proceedings)

    Science.gov (United States)

    Many watershed models simulate overland and instream microbial fate and transport, but few actually provide loading rates on land surfaces and point sources to the water body network. This paper describes the underlying general equations for microbial loading rates associated wit...

  20. Results of radiation therapy for uterine cervical cancer using high dose rate remote after loading system

    International Nuclear Information System (INIS)

    Ogawa, Yoshihiro; Nemoto, Kenji

    2003-01-01

    In Japan, radiotherapy with high dose rate remote after loading system (HDR-RALS) for intracavitary brachytherapy is the standard treatment for more than 30 years. This report showed the usefulness of HDR-RALS for uterine cervical cancer. From 1980 through 1999, 442 patients with uterine cervical cancers (stage I: 66, stage II: 161, stage III: 165, stage IV: 50) were treated. Radiotherapy was performed both external teletherapy and HDR-RALS. Overall survival rate at 5 years was 60.2%. The 5-year actuarial incidence of all complications was 16.4%. The 5-year actuarial incidence of all complications in cases treated with the sum doses of whole pelvic irradiation (without central shield) and RALS up to 49 Gy, 50 to 59 Gy or larger doses were 7.5%, 11.0% and 25.2%, respectively. Radiation therapy using HDR-RALS was very effective. While the dose of whole pelvic irradiation was increased, the actuarial incidence of all complications was increased. (author)

  1. Investigation of the Maximum Spin-Up Coefficients of Friction Obtained During Tests of a Landing Gear Having a Static-Load Rating of 20,000 Pounds

    Science.gov (United States)

    Batterson, Sidney A.

    1959-01-01

    An experimental investigation was made at the Langley landing loads track to obtain data on the maximum spin-up coefficients of friction developed by a landing gear having a static-load rating of 20,000 pounds. The forward speeds ranged from 0 to approximately 180 feet per second and the sinking speeds, from 2.7 feet per second to 9.4 feet per second. The results indicated the variation of the maximum spin-up coefficient of friction with forward speed and vertical load. Data obtained during this investigation are also compared with some results previously obtained for nonrolling tires to show the effect of forward speed.

  2. Rating of Perceived Exertion for Quantification of Training and Combat Loads During Combat Sport-Specific Activities: A Short Review.

    Science.gov (United States)

    Slimani, Maamer; Davis, Philip; Franchini, Emerson; Moalla, Wassim

    2017-10-01

    The aim of this short review was to summarize data pertaining to the rating of perceived exertion (RPE) methods (RPE value and session-RPE) during combat sport-specific activities (i.e., competition and training) based on many factors, including contest type (i.e., official vs. simulated vs. training), combat rounds, age of participants and muscle groups, and their correlation with physiological variables (i.e., blood lactate concentration [La] and heart rate [HR]). The current review shows higher RPE in a match of mixed martial arts (MMAs) than Brazilian jiu-jitsu and kickboxing matches and during the competitive period compared with the precompetitive period. This could be explained by the longer duration of bouts, the higher percentage contribution of aerobic metabolism in MMA than other combat sports and contest type differences (simulated vs. official matches). Thus, this review found significant correlations between RPE or session-RPE, [La] and HR. Particularly, there was a stronger correlation between RPE and [La] during official striking (r = 0.81) than grappling combat sports matches (r = 0.53). In addition, a variation of correlation (moderate to large) between session-RPE and HR-based methods has been reported (i.e., Edwards' training load [r ranged between 0.58 and 0.95] and Banister training impulse [r ranged between 0.52 and 0.86]). Specifically, stronger correlation was apparent in combat sport competition that required a much higher percentage contribution of aerobic metabolism (e.g., karate) and in adult athletes than anaerobic-based combat sports (e.g., taekwondo) and young athletes, respectively. Indeed, the current review highlights that the correlations between session-RPE and HR-based methods were higher during official competition than training sessions. Session-RPE was affected by participants' competitive level, the intensity of session (high vs. low), the training modalities (tactical-technical vs. technical-development vs. simulated

  3. Allostatic load and heart rate variability as health risk indicators.

    African Journals Online (AJOL)

    investigate the feasibility of inclusion of HRV indicators into allostatic load assessments and which HRV ... said to reflect stressor-induced activation of the two ... reduced in stress and said to be of prognostic value for ... Recruitment by a power point-illustrat- .... values (Total HRV and vagal activity dependent HRV) can.

  4. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load

    Science.gov (United States)

    Klepsch, Melina; Schmitz, Florian; Seufert, Tina

    2017-01-01

    Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 (N = 97), we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1) Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2) Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study (N = between 65 and 95 for each task), we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results. PMID:29201011

  5. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load.

    Science.gov (United States)

    Klepsch, Melina; Schmitz, Florian; Seufert, Tina

    2017-01-01

    Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 ( N = 97), we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1) Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2) Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study ( N = between 65 and 95 for each task), we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results.

  6. Development and Validation of Two Instruments Measuring Intrinsic, Extraneous, and Germane Cognitive Load

    Directory of Open Access Journals (Sweden)

    Melina Klepsch

    2017-11-01

    Full Text Available Cognitive Load Theory is one of the most powerful research frameworks in educational research. Beside theoretical discussions about the conceptual parts of cognitive load, the main challenge within this framework is that there is still no measurement instrument for the different aspects of cognitive load, namely intrinsic, extraneous, and germane cognitive load. Hence, the goal of this paper is to develop a differentiated measurement of cognitive load. In Study 1 (N = 97, we developed and analyzed two strategies to measure cognitive load in a differentiated way: (1 Informed rating: We trained learners in differentiating the concepts of cognitive load, so that they could rate them in an informed way. They were asked then to rate 24 different learning situations or learning materials related to either high or low intrinsic, extraneous, or germane load. (2 Naïve rating: For this type of rating of cognitive load we developed a questionnaire with two to three items for each type of load. With this questionnaire, the same learning situations had to be rated. In the second study (N = between 65 and 95 for each task, we improved the instrument for the naïve rating. For each study, we analyzed whether the instruments are reliable and valid, for Study 1, we also checked for comparability of the two measurement strategies. In Study 2, we conducted a simultaneous scenario based factor analysis. The informed rating seems to be a promising strategy to assess the different aspects of cognitive load, but it seems not economic and feasible for larger studies and a standardized training would be necessary. The improved version of the naïve rating turned out to be a useful, feasible, and reliable instrument. Ongoing studies analyze the conceptual validity of this measurement with up to now promising results.

  7. 49 CFR 393.108 - How is the working load limit of a tiedown, or the load restraining value of a friction mat...

    Science.gov (United States)

    2010-10-01

    ... load restraining value of a friction mat, determined? 393.108 Section 393.108 Transportation Other... load restraining value of a friction mat, determined? (a) The working load limit (WLL) of a tiedown... load limits. (g) Friction mats which are not marked or rated by the manufacturer shall be considered to...

  8. Pilot-scale anaerobic co-digestion of municipal biomass waste and waste activated sludge in China: Effect of organic loading rate

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xiao, E-mail: liuxiao07@mails.tsinghua.edu.cn [School of Environment, Tsinghua University, Beijing 100084 (China); Wang Wei; Shi Yunchun; Zheng Lei [School of Environment, Tsinghua University, Beijing 100084 (China); Gao Xingbao [Chinese Research Academy of Environmental Sciences, Beijing 100012 (China); Qiao Wei [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Zhou Yingjun [Department of Urban and Environmental Engineering, Graduate School of Engineering, Kyoto University, Katsura, Nisikyo-ku, Kyoto 615-8540 (Japan)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Co-digestion of municipal biomass waste (MBW) and waste activated sludge (WAS) was examined on a pilot-scale reactor. Black-Right-Pointing-Pointer System performance and stability under OLR of 1.2, 2.4, 3.6, 4.8, 6.0 and 8.0 kg VS (m{sup 3} d){sup -1} were analyzed. Black-Right-Pointing-Pointer A maximum methane production rate of 2.94 m{sup 3} (m{sup 3} d){sup -1} was achieved at OLR of 8.0 kg VS (m{sup 3} d){sup -1} and HRT of 15d. Black-Right-Pointing-Pointer With the increasing OLRs, pH values, VS removal rate and methane concentration decreased and VFA increased. Black-Right-Pointing-Pointer The changing of biogas production rate can be a practical approach to monitor and control anaerobic digestion system. - Abstract: The effects of organic loading rate on the performance and stability of anaerobic co-digestion of municipal biomass waste (MBW) and waste activated sludge (WAS) were investigated on a pilot-scale reactor. The results showed that stable operation was achieved with organic loading rates (OLR) of 1.2-8.0 kg volatile solid (VS) (m{sup 3} d){sup -1}, with VS reduction rates of 61.7-69.9%, and volumetric biogas production of 0.89-5.28 m{sup 3} (m{sup 3} d){sup -1}. A maximum methane production rate of 2.94 m{sup 3} (m{sup 3} d){sup -1} was achieved at OLR of 8.0 kg VS (m{sup 3} d){sup -1} and hydraulic retention time of 15 days. With increasing OLRs, the anaerobic reactor showed a decrease in VS removal rate, average pH value and methane concentration, and a increase of volatile fatty acid concentration. By monitoring the biogas production rate (BPR), the anaerobic digestion system has a higher acidification risk under an OLR of 8.0 kg VS (m{sup 3} d){sup -1}. This result remarks the possibility of relating bioreactor performance with BPR in order to better understand and monitor anaerobic digestion process.

  9. CrossTalk: The Journal of Defense Software Engineering. Volume 20, Number 11, November 2007

    National Research Council Canada - National Science Library

    2007-01-01

    ...: Partnership for Project Success." Jennifer Tucker and Hile Rutledge describe the necessity of maximizing team performance in "Shaping Motivation and Emotion in Technology Teams," and Kasey Thompson and Tim Border teach managers...

  10. 7 CFR 1710.206 - Approval requirements for load forecasts prepared pursuant to approved load forecast work plans.

    Science.gov (United States)

    2010-01-01

    ... financial ratings, and participation in reliability council, power pool, regional transmission group, power... analysis and modeling of the borrower's electric system loads as provided for in the load forecast work plan. (5) A narrative discussing the borrower's past, existing, and forecast of future electric system...

  11. Behaviour of eggshell membranes at tensile loading

    Czech Academy of Sciences Publication Activity Database

    Strnková, M.J.; Nedomová, Š.; Trnka, Jan; Buchar, J.; Kumbár, V.

    46 B, December (2014), s. 44-48 ISSN 0324-1130 Institutional support: RVO:61388998 Keywords : eggshell membrane * tensile loading * loading rate * stress * strain strength Subject RIV: GM - Food Processing Impact factor: 0.201, year: 2014

  12. Loading capacity of various filters for lithium fire generated aerosols

    International Nuclear Information System (INIS)

    Jeppson, D.W.; Barreca, J.R.

    1980-01-01

    The lithium aerosol loading capacity of a prefilter, HEPA filters and a sand and gravel bed filter was determined. The test aerosol was characterized and was generated by burning lithium in an unlimited air atmosphere. Correlation to sodium aerosol loading capacities were made to relate existing data to lithium aerosol loadings under varying conditions. This work is being conducted in support of the fusion reactor safety program. The lithium aerosol was generated by burning lithium pools, up to 45 kgs, in a 340 m 3 low humidity air atmosphere to supply aerosol to recirculating filter test loops. The aerosol was sampled to determine particle size, mass concentrations and chemical species. The dew point and gas concentrations were monitored throughout the tests. Loop inlet aerosol mass concentrations ranged up to 5 gr/m 3 . Chemical compounds analyzed to be present in the aerosol include Li 2 O, LiOH, and Li 2 CO 3 . HEPA filters with and without separators and a prefilter and HEPA filter in series were loaded with 7.8 to 11.1 kg/m 2 of aerosol at a flow rate of 1.31 m/sec and 5 kPa pressure drop. The HEPA filter loading capacity was determined to be greater at a lower flow rate. The loading capacity increased from 0.4 to 2.8 kg by decreasing the flow rate from 1.31 to 0.26 m/sec for a pressure drop of 0.11 kPa due to aerosol buildup. The prefilter tested in series with a HEPA did not increase the total loading capacity significantly for the same total pressure drop. Separators in the HEPA had only minor effect on loading capacity. The sand and gravel bed filter loaded to 0.50 kg/m 2 at an aerosol flow rate of 0.069 m/sec and final pressure drop of 6.2 kPa. These loading capacities and their dependence on test variables are similar to those reported for sodium aerosols except for the lithium aerosol HEPA loading capacity dependence upon flow rate

  13. High strain rate deformation and fracture of the magnesium alloy Ma2-1 under shock wave loading

    Science.gov (United States)

    Garkushin, G. V.; Kanel', G. I.; Razorenov, S. V.

    2012-05-01

    This paper presents the results of measurements of the dynamic elastic limit and spall strength under shock wave loading of specimens of the magnesium alloy Ma2-1 with a thickness ranging from 0.25 to 10 mm at normal and elevated (to 550°C) temperatures. From the results of measurements of the decay of the elastic precursor of a shock compression wave, it has been found that the plastic strain rate behind the front of the elastic precursor decreases from 2 × 105 s-1 at a distance of 0.25 mm to 103 s-1 at a distance of 10 mm. The plastic strain rate in a shock wave is one order of magnitude higher than that in the elastic precursor at the same value of the shear stress. The spall strength of the alloy decreases as the solidus temperature is approached.

  14. Optimization of cryoprotectant loading into murine and human oocytes.

    Science.gov (United States)

    Karlsson, Jens O M; Szurek, Edyta A; Higgins, Adam Z; Lee, Sang R; Eroglu, Ali

    2014-02-01

    Loading of cryoprotectants into oocytes is an important step of the cryopreservation process, in which the cells are exposed to potentially damaging osmotic stresses and chemical toxicity. Thus, we investigated the use of physics-based mathematical optimization to guide design of cryoprotectant loading methods for mouse and human oocytes. We first examined loading of 1.5 M dimethyl sulfoxide (Me(2)SO) into mouse oocytes at 23°C. Conventional one-step loading resulted in rates of fertilization (34%) and embryonic development (60%) that were significantly lower than those of untreated controls (95% and 94%, respectively). In contrast, the mathematically optimized two-step method yielded much higher rates of fertilization (85%) and development (87%). To examine the causes for oocyte damage, we performed experiments to separate the effects of cell shrinkage and Me(2)SO exposure time, revealing that neither shrinkage nor Me(2)SO exposure single-handedly impairs the fertilization and development rates. Thus, damage during one-step Me(2)SO addition appears to result from interactions between the effects of Me(2)SO toxicity and osmotic stress. We also investigated Me(2)SO loading into mouse oocytes at 30°C. At this temperature, fertilization rates were again lower after one-step loading (8%) in comparison to mathematically optimized two-step loading (86%) and untreated controls (96%). Furthermore, our computer algorithm generated an effective strategy for reducing Me(2)SO exposure time, using hypotonic diluents for cryoprotectant solutions. With this technique, 1.5 M Me(2)SO was successfully loaded in only 2.5 min, with 92% fertilizability. Based on these promising results, we propose new methods to load cryoprotectants into human oocytes, designed using our mathematical optimization approach. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Evaluation of self-assembled HCPT-loaded PEG-b-PLA nanoparticles by comparing with HCPT-loaded PLA nanoparticles.

    Science.gov (United States)

    Yang, Xiangrui; Wu, Shichao; Wang, Yange; Li, Yang; Chang, Di; Luo, Yin; Ye, Shefang; Hou, Zhenqing

    2014-12-01

    We present a dialysis technique to prepare the 10-hydroxycamptothecin (HCPT)-loaded nanoparticles (NPs) using methoxypolyethylene glycol-poly(D,L-lactide) (PEG-b-PLA) and PLA, respectively. Both HCPT-loaded PEG-b-PLA NPs and HCPT-loaded PLA NPs were characterized by differential scanning calorimetry (DSC), dynamic light scattering (DLS), transmission electron microscopy (TEM), scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). The results showed that the HCPT-loaded PEG-b-PLA NPs and HCPT-loaded PLA NPs presented a hydrodynamic particle size of 120.1 and 226.8 nm, with a polydispersity index of 0.057 and 0.207, a zeta potential of -31.2 and -45.7 mV, drug encapsulation efficiency of 44.52% and 44.94%, and drug-loaded content of 7.42% and 7.49%, respectively. The HCPT-loaded PEG-b-PLA NPs presented faster drug release rate compared to the HCPT-loaded PLA NPs. The HCPT-loaded PEG-b-PLA NPs presented higher cytotoxicity than the HCPT-loaded PLA NPs. These results suggested that the HCPT-loaded PEG-b-PLA NPs presented better characteristics for drug delivery compared to HCPT-loaded PLA NPs.

  16. Effect of engine load and biogas flow rate to the performance of a compression ignition engine run in dual-fuel (dieselbiogas) mode

    Science.gov (United States)

    Ambarita, H.

    2018-02-01

    The Government of Indonesia (GoI) has released a target on reduction Green Houses Gases emissions (GHG) by 26% from level business-as-usual by 2020, and the target can be up to 41% by international supports. In the energy sector, this target can be reached effectively by promoting fossil fuel replacement or blending with biofuel. One of the potential solutions is operating compression ignition (CI) engine in dual-fuel (diesel-biogas) mode. In this study effects of engine load and biogas flow rate on the performance and exhaust gas emissions of a compression ignition engine run in dual-fuel mode are investigated. In the present study, the used biogas is refined with methane content 70% of volume. The objectives are to explore the optimum operating condition of the CI engine run in dual-fuel mode. The experiments are performed on a four-strokes CI engine with rated output power of 4.41 kW. The engine is tested at constant speed 1500 rpm. The engine load varied from 600W to 1500W and biogas flow rate varied from 0 L/min to 6 L/min. The results show brake thermal efficiency of the engine run in dual-fuel mode is better than pure diesel mode if the biogas flow rates are 2 L/min and 4 L/min. It is recommended to operate the present engine in a dual-fuel mode with biogas flow rate of 4 L/min. The consumption of diesel fuel can be replaced up to 50%.

  17. Loading nature of the interfacial cracks in a joint component under fusion-relevant thermal loads

    International Nuclear Information System (INIS)

    You, J.H.

    1998-01-01

    One of the standard design concepts for divertor components in a fusion reactor is the bonded joint structure. Understanding the loading nature of interfacial cracks are significant for the assessment of structural integrity of divertor joint components. In this paper, the thermomechanical loading nature of interfacial cracks is discussed. A bi-material joint element consisting of the CFC/TZM system is considered. A typical fusion operation condition is simulated assuming a pulsed high heat flux loading. Stress singularities near the interfacial crack tips are characterized quantitatively in terms of the fracture mechanical parameters. The evolution of the stress intensity factors and the energy release rate during the given transient thermal load are determined. The difference in loading characteristics between the edge crack and the center crack is discussed. High heat flux cycling tests are performed on brazed CFC/TZM divertor elements in an electron beam test facility. The microstructures of the damaged interface agree with the predicted fracture modes. The loading nature and possible failure mechanisms are discussed for a fusion-relevant thermal loading. (orig.)

  18. Progress in generating fracture data base as a function of loading rate and temperature using small-scale tests

    International Nuclear Information System (INIS)

    Couque, H.; Hudak, S.J. Jr.

    1993-01-01

    Structural integrity assessment of nuclear pressure vessels requires small specimen fracture testing to generate data over a wide range of material loading, and temperature conditions. Small scale testing is employed since extensive testing is required including small radiation embrittled samples from nuclear surveillance capsules. However, current small scale technology does not provide the needed dynamic fracture toughness relevant to the crack arrest/reinitiation events that may occur during pressurized thermal shock transients following emergency shutdown. This paper addresses the generation of this much needed dynamic toughness data using a novel experimental-computational approach involving a coupled pressure bars (CPB) technique and a viscoplastic dynamic fracture code. CPB data have been generated to testing temperatures never before reached: 37 to 100 degrees C -- 60 to 123 degrees C above the nil ductility transition temperature. Fracture behavior of pressure vessel steel from lower shelf to upper shelf temperatures and previous toughness estimates for the 10 6 MPa√m s -1 loading rate regime are assessed in light of the new CPB data. 26 refs., 14 figs., 3 tabs

  19. A master curve-mechanism based approach to modeling the effects of constraint, loading rate and irradiation on the toughness-temperature behavior of a V-4Cr-4Ti alloy

    International Nuclear Information System (INIS)

    Odette, G.R.; Donahue, E.; Lucas, G.E.; Sheckherd, J.W.

    1996-01-01

    The influence of loading rate and constraint on the effective fracture toughness as a function of temperature [K e (T)] of the fusion program heat of V-4Cr-4Ti was measured using subsized, three point bend specimens. The constitutive behavior was characterized as a function of temperature and strain rate using small tensile specimens. Data in the literature on this alloy was also analysed to determine the effect of irradiation on K e (T) and the energy temperature (E-T) curves measured in subsized Charpy V-notch tests. It was found that V-4Cr-4Ti undergoes open-quotes normalclose quotes stress-controlled cleavage fracture below a temperature marking a sharp ductile-to-brittle transition. The transition temperature is increased by higher loading rates, irradiation hardening and triaxial constraint. Shifts in a reference transition temperature due to higher loading rates and irradiation can be reasonably predicted by a simple equivalent yield stress model. These results also suggest that size and geometry effects, which mediate constraint, can be modeled by combining local critical stressed area σ*/A* fracture criteria with finite element method simulations of crack tip stress fields. The fundamental understanding reflected in these models will be needed to develop K e (T) curves for a range of loading rates, irradiation conditions, structural size scales and geometries relying (in large part) on small specimen tests. Indeed, it may be possible to develop a master K e (T) curve-shift method to account for these variables. Such reliable and flexible failure assessment methods are critical to the design and safe operation of defect tolerant vanadium structures

  20. Effect of organic loading rate on anaerobic treatment of slaughterhouse wastewater in a fluidised-bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Borja, R. [Consejo Superior de Investigaciones Cientificas, Seville (Spain). Inst. de la Grasa; Banks, C.J.; Zhengjian Wang [Manchester Univ. (United Kingdom). Inst. of Science and Technology

    1995-09-01

    COD removal efficiencies in the range 75.0-98.9% were achieved in an aerobic fluidised-bed reactor treating slaughterhouse wastewater, when evaluated at organic loading rates (OLR) of between 2.9 and 54.0 g COD/l.d, hydraulic retention times (HRT) of between 0.5 and 8 h and feed COD concentrations of between 250 and 4500 mg/l. More than 94% of feed COD could be removed up to OLR of about 27 g COD/l.d. Up to 0.320 litres of methane were produced per gram of COD removed and this methane production rate was independent of the OLR applied in this investigation. Volatile fatty acid (VFA) concentration in the reactor increased sharply at an OLR of about 30 g COD/l.d and, therefore, sufficient alkalinity should be provided to prevent pH from dropping to an undesirable level. The anaerobic fluidised-bed system can be operated at a significantly higher liquid throughput than other previously reported systems while maintaining its excellent efficiency. (Author)

  1. Macrocrack propagation in concrete specimens under sustained loading: Study of the physical mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Pierre, E-mail: pierre.rossi@lcpc.fr; Boulay, Claude; Tailhan, Jean-Louis; Martin, Eric; Desnoyers, Dominic

    2014-09-15

    This study presents a series of 4-point bending tests performed to describe the delayed behavior of unreinforced pre-cracked beams under low, moderate and high sustained loading levels. The deflection creep rate, the failure time and the load level were assessed. A linear relation, in a semi-log scale, was found for the deflection creep rate at high load levels. In addition, a linear relation, in a log–log scale, between the secondary deflection creep rate and failure time was observed. Besides, it was shown that the secondary creep deflection rate increases with the sustained loading level and the macrocrack propagation rate when macrocrack propagation occurs during the sustained loading. Physical mechanisms are proposed to explain these results and may be summarized as follows: the delayed behavior of an unreinforced cracked concrete specimen under sustained loading is mainly due to the cracking evolution, thus the creation of microcracks and/or the propagation of a macrocrack.

  2. Macrocrack propagation in concrete specimens under sustained loading: Study of the physical mechanisms

    International Nuclear Information System (INIS)

    Rossi, Pierre; Boulay, Claude; Tailhan, Jean-Louis; Martin, Eric; Desnoyers, Dominic

    2014-01-01

    This study presents a series of 4-point bending tests performed to describe the delayed behavior of unreinforced pre-cracked beams under low, moderate and high sustained loading levels. The deflection creep rate, the failure time and the load level were assessed. A linear relation, in a semi-log scale, was found for the deflection creep rate at high load levels. In addition, a linear relation, in a log–log scale, between the secondary deflection creep rate and failure time was observed. Besides, it was shown that the secondary creep deflection rate increases with the sustained loading level and the macrocrack propagation rate when macrocrack propagation occurs during the sustained loading. Physical mechanisms are proposed to explain these results and may be summarized as follows: the delayed behavior of an unreinforced cracked concrete specimen under sustained loading is mainly due to the cracking evolution, thus the creation of microcracks and/or the propagation of a macrocrack

  3. A test-retest assessment of the effects of mental load on ratings of affect, arousal and perceived exertion during submaximal cycling.

    Science.gov (United States)

    Vera, Jesús; Perales, José C; Jiménez, Raimundo; Cárdenas, David

    2018-04-24

    This study aimed to test the effects of mental (i.e. executive) load during a dual physical-mental task on ratings of perceived exertion (RPE), affective valence, and arousal. The protocol included two dual tasks with matched physical demands but different executive demands (2-back and oddball), carried out on different days. The procedure was run twice to assess the sensitivity and stability of RPE, valence and arousal across the two trials. Linear mixed-effects analyses showed less positive valence (-0.44 points on average in a 1-9 scale; R β 2  = 0.074 [CI90%, 0.052-0.098]), and heightened arousal (+0.13 points on average in a 1-9 scale; R β 2  = 0.006 [CI90%, 0.001-0.015]), for the high executive load condition, but showed no effect of mental load on RPE. Separated analyses for the two task trials yielded best-fitting models that were identical across trials for RPE and valence, but not for arousal. Model fitting was improved by assuming a 1-level autoregressive covariance structure for all analyses. In conclusion, executive load during a dual physical-mental task modulates the emotional response to effort, but not RPE. The autoregressive covariance suggests that people tend to anchor estimates on prior ones, which imposes certain limits on scales' usability.

  4. Design of dynamic loading support on high temperature pipe

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    As a follow up to pipe stress analysis result caused by high temperature operation loading, a design of dynamic loading support was made. The type of variable and constant support as acceptable choosing are applicated for reduce of over stress and over load on piping system. Analysis line schedule of AP600 as an example with apply three dynamic loading support (two type variable and one type constant support). The pre-design of the third support above are based on analysis result with follow the support catalog and field condition wherein its supports are installed. To guarantee the performance and accurate of the support, checking is performed for spring working rate tolerance, support variability and swing angle. The design results of variable spring are loads, size, working rate, type tolerance, spring rate, variability, long and sway angle with each values 5000; 15; 1,25; VM; 0.655; 1080; 0.114; 114,5; 0,48 for S1 and 2045; 12; 0,583; VS; 0,237; 900; 0,132; 130; 0,34 for S3

  5. Dorzolamide Loaded Niosomal Vesicles: Comparison of Passive and Remote Loading Methods.

    Science.gov (United States)

    Hashemi Dehaghi, Mohadeseh; Haeri, Azadeh; Keshvari, Hamid; Abbasian, Zahra; Dadashzadeh, Simin

    2017-01-01

    Glaucoma is a common progressive eye disorder and the treatment strategies will benefit from nanoparticulate delivery systems with high drug loading and sustained delivery of intraocular pressure lowering agents. Niosomes have been reported as a novel approach to improve drug low corneal penetration and bioavailability characteristics. Along with this, poor entrapment efficiency of hydrophilic drug in niosomal formulation remains as a major formulation challenge. Taking this perspective into consideration, dorzolamide niosomes were prepared employing two different loading methodologies (passive and remote loading methods) and the effects of various formulation variables (lipid to drug ratio, cholesterol percentage, drug concentration, freeze/thaw cycles, TPGS content, and external and internal buffer molarity and pH) on encapsulation efficiency were assessed. Encapsulation of dorzolamide within niosomes increased remarkably by the incorporation of higher cholesterol percentage as well as increasing the total lipid concentration. Remote loading method showed higher efficacy for drug entrapment compared to passive loading technique. Incorporation of TPGS in bilayer led to decrease in EE; however, retarded drug release rate. Scanning electron microscopy (SEM) studies confirmed homogeneous particle distribution, and spherical shape with smooth surface. In conclusion, the highest encapsulation can be obtained using phosphate gradient method and 50% cholesterol in Span 60 niosomal formulation.

  6. Varietal and harvesting time effects on physical characteristics and ...

    African Journals Online (AJOL)

    SARAH

    2014-10-31

    Oct 31, 2014 ... characteristics and acceptability of boiled fresh yellow maize hybrids. Methodology and ... bridge the hunger gap after a long dry season(. Osanyintola ... and produced lower yields of prime grits when milled dry (Rutledge ...

  7. Visual perceptual load induces inattentional deafness.

    Science.gov (United States)

    Macdonald, James S P; Lavie, Nilli

    2011-08-01

    In this article, we establish a new phenomenon of "inattentional deafness" and highlight the level of load on visual attention as a critical determinant of this phenomenon. In three experiments, we modified an inattentional blindness paradigm to assess inattentional deafness. Participants made either a low- or high-load visual discrimination concerning a cross shape (respectively, a discrimination of line color or of line length with a subtle length difference). A brief pure tone was presented simultaneously with the visual task display on a final trial. Failures to notice the presence of this tone (i.e., inattentional deafness) reached a rate of 79% in the high-visual-load condition, significantly more than in the low-load condition. These findings establish the phenomenon of inattentional deafness under visual load, thereby extending the load theory of attention (e.g., Lavie, Journal of Experimental Psychology. Human Perception and Performance, 25, 596-616, 1995) to address the cross-modal effects of visual perceptual load.

  8. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D.

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially. PMID:26082709

  9. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory.

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  10. Mechanical Behaviour of Bolted Joints Under Impact Rates of Loading

    Science.gov (United States)

    2012-01-01

    M. (1995). Bearing Strength of Autoclave and oven cured kevlar / epoxy laminates under static and dynamic loading. Compostes, 451-456. Kretsis, G...Joints in Glass Fibre/ Epoxy Laminates. Composites, Volume 16. No 2. Kolsky, H. (1949). An Investigation of the Mechanical Properties of Materials at...elongating the pulse width. The responses are read by the strain gages bonded on the incident and transmission bar with Vishay AE-10 epoxy . The gages

  11. Impact of Organic Loading Rate on Psychrophilic Anaerobic Digestion of Solid Dairy Manure

    Directory of Open Access Journals (Sweden)

    Noori M. Cata Saady

    2015-03-01

    Full Text Available Increasing the feed total solids to anaerobic digester improves the process economics and decreases the volume of liquid effluent from current wet anaerobic digestion. The objective of this study was to develop a novel psychrophilic (20 °C anaerobic digestion technology of undiluted cow feces (total solids of 11%–16%. Two sets of duplicate laboratory-scale sequence batch bioreactors have been operated at organic loading rates (OLR of 6.0 to 8.0 g total chemical oxygen demand (TCOD kg−1 inoculum day−1 (d−1 during 210 days. The results demonstrated that the process is feasible at treatment cycle length (TCL of 21 days; however, the quality of cow feces rather than the OLR had a direct influence on the specific methane yield (SMY. The SMY ranged between 124.5 ± 1.4 and 227.9 ± 4.8 normalized liter (NL CH4 kg−1 volatile solids (VS fed d−1. Substrate-to-inoculum mass ratio (SIR was 0.63 ± 0.05, 0.90 ± 0.09, and 1.06 ± 0.07 at OLR of 6.0, 7.0, and 8.0 g TCOD kg−1 inoculum d−1, respectively. No volatile fatty acids (VFAs accumulation has been observed which indicated that hydrolysis was the rate limiting step and VFAs have been consumed immediately. Bioreactors performance consistency in terms of the level of SMYs, VFAs concentrations at end of the TCL, pH stability and volatile solids reduction indicates a stable and reproducible process during the entire operation.

  12. Reactor pressure elevation preventing device upon interruption of load

    International Nuclear Information System (INIS)

    Ota, Yasuo; Okukawa, Ryutaro.

    1996-01-01

    In a power load imbalance circuit of a steam turbine control device, a power load imbalance occurrence signal is outputted for a predetermined period of time upon occurrence of load interruption. A function for suppressing increase of number of rotation of a turbine due to load interruption is not disturbed, and the power load imbalance circuit is not operated at least after a primary peak where the number of rotation of the turbine is increased. Since a steam control valve flow rate demand signal and a turbine bypass valve flow rate demand signals are corporated subsequently to control the opening degree of the steam control valve and the turbine bypass valve, elevation of reactor pressure is always suppressed and maintained constant, as well as abrupt opening of the steam control valve due to cancel of the power load imbalance circuit when steam control valve opening demand is outputted can be prevented. (N.H.)

  13. Estimation of structural reliability under combined loads

    International Nuclear Information System (INIS)

    Shinozuka, M.; Kako, T.; Hwang, H.; Brown, P.; Reich, M.

    1983-01-01

    For the overall safety evaluation of seismic category I structures subjected to various load combinations, a quantitative measure of the structural reliability in terms of a limit state probability can be conveniently used. For this purpose, the reliability analysis method for dynamic loads, which has recently been developed by the authors, was combined with the existing standard reliability analysis procedure for static and quasi-static loads. The significant parameters that enter into the analysis are: the rate at which each load (dead load, accidental internal pressure, earthquake, etc.) will occur, its duration and intensity. All these parameters are basically random variables for most of the loads to be considered. For dynamic loads, the overall intensity is usually characterized not only by their dynamic components but also by their static components. The structure considered in the present paper is a reinforced concrete containment structure subjected to various static and dynamic loads such as dead loads, accidental pressure, earthquake acceleration, etc. Computations are performed to evaluate the limit state probabilities under each load combination separately and also under all possible combinations of such loads

  14. A Preliminary Study on Bucket Foundations under Transient Lateral Loading

    DEFF Research Database (Denmark)

    Foglia, Aligi; Ibsen, Lars Bo; Nielsen, Søren Kjær

    2013-01-01

    This study aims at investigating the behaviour of monopod bucket foundations through a physical model. The foundation is installed in dense water-saturated sand and is subjected to lateral load applied at different rates. The different loading rates allow for exploring the patterns of response of...

  15. Unusual ISS Rate Signature

    Science.gov (United States)

    Laible, Michael R.

    2011-01-01

    On November 23, 2011 International Space Station Guidance, Navigation, and Control reported unusual pitch rate disturbance. These disturbances were an order of magnitude greater than nominal rates. The Loads and Dynamics team was asked to review and analyze current accelerometer data to investigate this disturbance. This paper will cover the investigation process under taken by the Loads and Dynamics group. It will detail the accelerometers used and analysis performed. The analysis included performing Frequency Fourier Transform of the data to identify the mode of interest. This frequency data is then reviewed with modal analysis of the ISS system model. Once this analysis is complete and the disturbance quantified, a forcing function was produced to replicate the disturbance. This allows the Loads and Dynamics team to report the load limit values for the 100's of interfaces on the ISS.

  16. African Zoology - Vol 44, No 2 (2009)

    African Journals Online (AJOL)

    ) in the Okavango Delta, Botswana · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Rutledge S. Boyes, Michael R. Perrin, 181-193. http://dx.doi.org/10.3377/004.044.0206 ...

  17. The Effect of Organic Loading Rate on Milk WastewaterTreatment Using Sequencing Batch Reactor (SBR

    Directory of Open Access Journals (Sweden)

    Hooman Hajiabadi

    2009-09-01

    Full Text Available In this study, four aerobic sequencing batch reactors (SBRs were operated under the same conditions for the treatment of milk wastewater at different organic loading rates (OLRs. Cylindrical Plexiglas reactors were run for 56 days (including 21 days of acclimatization and 35 days of data gathering. Effective volume, influent wastewater flowrate, and sludge retention time (SRT of reactors were 5.5 L, 3.5 L/d, and 10 d, respectively. The average COD removal efficiency for the reactors R1, R2, R3, and R4 with influent OLRave values of 633, 929, 1915, and 3261 gCOD/m3d were 95, 96, 95, and 82 percent, respectively. The average effluent suspended solid (SS for all reactors was lower than 44 mg/L. Also, except for R4 with an average effluent turbidity of 270 NTU, other reactors met the Iranian wastewater emission standard (50 NTU. In addition, the average sludge volume index of reactors R1 to R3 was found to be lower than 67 mL/g. According to the results, the overall variation of COD removal efficiency versus influent OLR shows a decreasing rate with a correlation factor of 0.8 (R2.

  18. Ice load reducer for dams : laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Lupien, R.; Cote, A.; Robert, A. [Institut de Recherche d' Hydro-Quebec, Varennes, PQ (Canada)

    2009-07-01

    Many studies have focused on measuring static ice loads on various hydraulic structures in Canada. This paper discussed a Hydro-Quebec research project whose main purpose was to harmonize the ice thrust value in load combinations for use in general hydraulic works or for specific cases. The objectives of the project were to obtain a better understanding of existing data and to characterize sites and their influence on ice thrust; study the structural mechanisms involved in the generation of ice thrust, their consequences on the structural behaviour of ice and the natural mitigating circumstances that may be offered by ice properties or site operating procedures; and examine the relevance of developing an ice load reducer for works that might not fit the harmonized design value. The paper presented the main research goals and ice load reducer goals, with particular focus on the four pipe samples that were planned, built and tested. The experimental program involved checking the pipe shape behaviour in terms of flexibility-stiffness; maximum deformations; maximum load reduction; permanent deformations; and, ability to shape recovering. The testing also involved examining the strength versus strain rate; creep versus strain rate; and creep capacity under biaxial state of tension and compression. It was concluded that the two phenomena involved in generation of ice thrust, notably thermal expansion and water level changes, had very low strain rates. 8 refs., 2 tabs., 16 figs.

  19. Stress-associated cardiovascular reaction masks heart rate dependence on physical load in mice.

    Science.gov (United States)

    Andreev-Andrievskiy, A A; Popova, A S; Borovik, A S; Dolgov, O N; Tsvirkun, D V; Custaud, M; Vinogradova, O L

    2014-06-10

    When tested on the treadmill mice do not display a graded increase of heart rate (HR), but rather a sharp shift of cardiovascular indices to high levels at the onset of locomotion. We hypothesized that under test conditions cardiovascular reaction to physical load in mice is masked with stress-associated HR increase. To test this hypothesis we monitored mean arterial pressure (MAP) and heart rate in C57BL/6 mice after exposure to stressful stimuli, during spontaneous locomotion in the open-field test, treadmill running or running in a wheel installed in the home cage. Mice were treated with β1-adrenoblocker atenolol (2mg/kg ip, A), cholinolytic ipratropium bromide (2mg/kg ip, I), combination of blockers (A+I), anxiolytic diazepam (5mg/kg ip, D) or saline (control trials, SAL). MAP and HR in mice increased sharply after handling, despite 3weeks of habituation to the procedure. Under stressful conditions of open field test cardiovascular parameters in mice were elevated and did not depend on movement speed. HR values did not differ in I and SAL groups and were reduced with A or A+I. HR was lower at rest in D pretreated mice. In the treadmill test HR increase over speeds of 6, 12 and 18m/min was roughly 1/7-1/10 of HR increase observed after placing the mice on the treadmill. HR could not be increased with cholinolytic (I), but was reduced after sympatholytic (A) or A+I treatment. Anxiolytic (D) reduced heart rate at lower speeds of movement and its overall effect was to unmask the dependency of HR on running speed. During voluntary running in non-stressful conditions of the home cage HR in mice linearly increased with increasing running speeds. We conclude that in test situations cardiovascular reactions in mice are governed predominantly by stress-associated sympathetic activation, rendering efforts to evaluate HR and MAP reactions to workload unreliable. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Mitigating the Long term Operating Extreme Load through Active Control

    International Nuclear Information System (INIS)

    Koukoura, Christina; Natarajan, Anand

    2014-01-01

    The parameters influencing the long term extreme operating design loads are identified through the implementation of a Design of Experiment (DOE) method. A function between the identified critical factors and the ultimate out-of-plane loads on the blade is determined. Variations in the initial blade azimuth location are shown to affect the extreme blade load magnitude during operation in normal turbulence wind input. The simultaneously controlled operation of generator torque variation and pitch variation at low blade pitch angles is detected to be responsible for very high loads acting on the blades. Through gain scheduling of the controller (modifications of the proportional Kp and the integral K gains) the extreme loads are mitigated, ensuring minimum instantaneous variations in the power production for operation above rated wind speed. The response of the blade load is examined for different values of the integral gain as resulting in rotor speed error and the rate of change of rotor speed. Based on the results a new load case for the simulation of extreme loads during normal operation is also presented

  1. Biomechanical response of human spleen in tensile loading.

    Science.gov (United States)

    Kemper, Andrew R; Santago, Anthony C; Stitzel, Joel D; Sparks, Jessica L; Duma, Stefan M

    2012-01-10

    Blunt splenic injuries are most frequently caused as a result of motor vehicle collisions and are associated with high mortality rates. In order to accurately assess the risk of automotive related spleen injuries using tools such as finite element models, tissue level tolerance values and suitable material models must be developed and validated based on appropriate biomechanical data. This study presents a total of 41 tension tests performed on spleen parenchyma coupons and 29 tension tests performed on spleen capsule/parenchyma coupons. Standard dog-bone coupons were obtained from fresh human spleen and tested within 48 h of death. Each coupon was tested once to failure at one of the four loading rates to investigate the effects of rate dependence. Load and acceleration data were obtained at each of the specimen grips. High-speed video and optical markers placed on the specimens were used to measure local displacement. Failure stress and strain were calculated at the location of failure in the gage length of the coupon. The results of the study showed that both the spleen parenchyma and the capsule are rate dependent, with higher loading rates yielding higher failure stresses and lower failure strains. The results also show that the failure stress of the splenic capsule is significantly greater than that of the underlying parenchyma. Overall, this study provides novel biomechanical data that demonstrate the rate dependent tissue level tolerance values of human spleen tissue in tensile loading, which can aid in the improvement of finite element models used to assess injury risk in blunt trauma. Published by Elsevier Ltd.

  2. Enhancement of glomerular filtration rate and renal plasma flow by oral glucose load in well controlled insulin-dependent diabetics

    DEFF Research Database (Denmark)

    Sandahl Christiansen, J; Christensen, C K; Hermansen, K

    1986-01-01

    Glomerular filtration rate (GFR) and renal plasma flow (RPF) were measured in 27 patients with uncomplicated insulin-dependent diabetes (IDDM) before and after an oral glucose load of 1.1 g glucose/kg body wt. In the 18 patients showing near-normoglycaemia (blood glucose less than or equal to 8...... mmol/l) before the glucose challenge the increase in blood glucose from 4.2 +/- 1.7 to 15.2 +/- 2.3 mmol/l was accompanied by an enhancement of GFR from 128 +/- 15 to 132 +/- 14 ml/min X 1.73 m2 (2p = 0.030) and of RPF from 534 +/- 116 to 562 +/- 105 ml/min X 1.73 m2 (2p = 0.023). By contrast oral...... glucose load to the nine patients with hyperglycaemia (greater than 8 mmol/l) during baseline conditions raising blood glucose from 11.9 +/- 2.0 to 19.6 +/- 1.5 mmol/l was accompanied by a reduction in GFR from 149 +/- 15 to 139 +/- 9 ml/min X 1.73 m2 (2p less than 0.001) while RPF was unchanged...

  3. Measuring cognitive load: performance, mental effort and simulation task complexity.

    Science.gov (United States)

    Haji, Faizal A; Rojas, David; Childs, Ruth; de Ribaupierre, Sandrine; Dubrowski, Adam

    2015-08-01

    Interest in applying cognitive load theory in health care simulation is growing. This line of inquiry requires measures that are sensitive to changes in cognitive load arising from different instructional designs. Recently, mental effort ratings and secondary task performance have shown promise as measures of cognitive load in health care simulation. We investigate the sensitivity of these measures to predicted differences in intrinsic load arising from variations in task complexity and learner expertise during simulation-based surgical skills training. We randomly assigned 28 novice medical students to simulation training on a simple or complex surgical knot-tying task. Participants completed 13 practice trials, interspersed with computer-based video instruction. On trials 1, 5, 9 and 13, knot-tying performance was assessed using time and movement efficiency measures, and cognitive load was assessed using subjective rating of mental effort (SRME) and simple reaction time (SRT) on a vibrotactile stimulus-monitoring secondary task. Significant improvements in knot-tying performance (F(1.04,24.95)  = 41.1, p cognitive load (F(2.3,58.5)  = 57.7, p load among novices engaged in simulation-based learning. These measures can be used to track cognitive load during skills training. Mental effort ratings are also sensitive to small differences in intrinsic load arising from variations in the physical complexity of a simulation task. The complementary nature of these subjective and objective measures suggests their combined use is advantageous in simulation instructional design research. © 2015 John Wiley & Sons Ltd.

  4. Fifty years of genetic load

    International Nuclear Information System (INIS)

    Wallace, B.

    1991-01-01

    This book discusses the radiation effects on Drosophila. It was originally thought that irradiating Drosophila would decrease the average fitness of the population, thereby leading to information about the detrimental effects of mutations. Surprisingly, the fitness of the irradiated population turned out to be higher than that of the control population. The original motivation for the experiment was as a test of genetic load theory. The average fitness of a population is depressed by deleterious alleles held in the population by the balance between mutation and natural selection. The depression is called the genetic load of the population. The load dose not depend on the magnitude of the deleterious effect of alleles, but only on the mutation rate

  5. The economics of using prophylactic antibiotic-loaded bone cement in total knee replacement.

    Science.gov (United States)

    Gutowski, C J; Zmistowski, B M; Clyde, C T; Parvizi, J

    2014-01-01

    The rate of peri-prosthetic infection following total joint replacement continues to rise, and attempts to curb this trend have included the use of antibiotic-loaded bone cement at the time of primary surgery. We have investigated the clinical- and cost-effectiveness of the use of antibiotic-loaded cement for primary total knee replacement (TKR) by comparing the rate of infection in 3048 TKRs performed without loaded cement over a three-year period versus the incidence of infection after 4830 TKRs performed with tobramycin-loaded cement over a later period of time of a similar duration. In order to adjust for confounding factors, the rate of infection in 3347 and 4702 uncemented total hip replacements (THR) performed during the same time periods, respectively, was also examined. There were no significant differences in the characteristics of the patients in the different cohorts. The absolute rate of infection increased when antibiotic-loaded cement was used in TKR. However, this rate of increase was less than the rate of increase in infection following uncemented THR during the same period. If the rise in the rate of infection observed in THR were extrapolated to the TKR cohort, 18 additional cases of infection would have been expected to occur in the cohort receiving antibiotic-loaded cement, compared with the number observed. Depending on the type of antibiotic-loaded cement that is used, its cost in all primary TKRs ranges between USD $2112.72 and USD $112 606.67 per case of infection that is prevented.

  6. Load leveling total system. Part 2. Development of load leveling logic for residential customer; Fuka heijunka total system. 2. Kateiyo juyoka wo taisho to shita heijunka ronri no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Asari, M.; Nanahara, T. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1995-05-01

    It is essential, in order to meet steadily increasing demands for electrical power, to develop techniques for effective utilization of energy and load leveling. Described herein is development, by the aid of linear programming, of logic for daily management of charge/discharge of load conditioners and reverse power flow, for predicted loads and patterns of power generated by photovoltaic cells installed at individual customers. It is aimed at minimizing power rate and leveling of load at distribution systems. Predicted loads, outputs by photovoltaic cell units and different power rates by time zone for the next day are inputted, to determine the charge/discharge schedules and power supply/reverse flow patterns for that day, in order to minimize power rates and level loads at higher hierarchical levels. The logic-aided daily simulation for various districts confirms the operational patterns that realize improved utilization of pole-mounted transformers while reducing costs at customers, and effects of prediction errors. 4 refs., 14 figs.

  7. Influence of bending deflection rate on properties of fibrous mortar

    Directory of Open Access Journals (Sweden)

    Metwally Abd Allah Abd el Aty

    2013-04-01

    Full Text Available Selection of the construction materials is affected by many factors including their properties under the applied loads. Loading rate is considered as a very important parameter which influences the behavior of the materials. Fibrous concrete is commonly used in applications in which the loading rate exceeds quasi static conditions by a large margin. This paper investigates the influence of flexural loading rate on the performance of fibrous concrete prisms in flexure. Two hundred and fifty two prisms include fibrous concrete and control specimens were prepared and tested. Fiber type, fiber dosage and flexural loading rate were the main parameters considered in this study. Two types of fibers were investigated namely polypropylene fibers and glass fibers. Three dosages of fiber volume fractions were implemented as 0.5%, 1.0% and 2.0%. A total of 12 different rates of displacement (0.0039 up to 8 mm/s for load application were conducted. A computer controlled universal testing machine provided with data acquisition system capable of performing 1000 loop per second was used. Load–central deflection, flexural strength and toughness were the evaluated properties for the investigated specimens. The results indicated that the flexure strength values exhibited loading rate dependence not only for the control mix but also for the investigated fibrous mortar mixes. Also the performance in flexure varied substantially not only with loading rate but with fiber type and fiber volume fractions as well.

  8. Application of subsurface wastewater infiltration system to on-site treatment of domestic sewage under high hydraulic loading rate

    Directory of Open Access Journals (Sweden)

    Ying-hua Li

    2015-01-01

    Full Text Available In order to enhance the hydraulic loading rate (HLR of a subsurface wastewater infiltration system (SWIS used in treating domestic sewage, the intermittent operation mode was employed in the SWIS. The results show that the intermittent operation mode contributes to the improvement of the HLR and the pollutant removal rate. When the wetting-drying ratio (RWD was 1.0, the pollutant removal rate increased by (13.6 ± 0.3% for NH3-N, (20.7 ± 1.1% for TN, (18.6 ± 0.4% for TP, (12.2 ± 0.5% for BOD, (10.1 ± 0.3% for COD, and (36.2 ± 1.2% for SS, compared with pollutant removal rates under the continuous operation mode. The pollutant removal rate declined with the increase of the HLR. The effluent quality met The Reuse of Urban Recycling Water – Water Quality Standard for Scenic Environment Use (GB/T 18921-2002 even when the HLR was as high as 10 cm/d. Hydraulic conductivity, oxidation reduction potential (ORP, the quantity of nitrifying bacteria, and the pollutant removal rate of NH3-N increased with the decrease of the RWD. For the pollutant removal rates of TP, BOD, and COD, there were no significant difference (p < 0.05 under different RWDs. The suggested RWD was 1.0. Relative contribution of the pretreatment and SWIS to the pollutant removal was examined, and more than 80% removal of NH3-N, TN, TP, COD, and BOD occurred in the SWIS.

  9. Estimation of the dust production rate from the tungsten armour after repetitive ELM-like heat loads

    Science.gov (United States)

    Pestchanyi, S.; Garkusha, I.; Makhlaj, V.; Landman, I.

    2011-12-01

    Experimental simulations for the erosion rate of tungsten targets under ITER edge-localized mode (ELM)-like surface heat loads of 0.75 MJ m-2 causing surface melting and of 0.45 MJ m-2 without melting have been performed in the QSPA-Kh50 plasma accelerator. Analytical considerations allow us to conclude that for both energy deposition values the erosion mechanism is solid dust ejection during surface cracking under the action of thermo-stress. Tungsten influx into the ITER containment of NW~5×1018 W per medium size ELM of 0.75 MJ m-2 and 0.25 ms time duration has been estimated. The radiation cooling power of Prad=150-300 MW due to such influx of tungsten is intolerable: it should cool the ITER core to 1 keV within a few seconds.

  10. Estimation of the dust production rate from the tungsten armour after repetitive ELM-like heat loads

    International Nuclear Information System (INIS)

    Pestchanyi, S; Landman, I; Garkusha, I; Makhlaj, V

    2011-01-01

    Experimental simulations for the erosion rate of tungsten targets under ITER edge-localized mode (ELM)-like surface heat loads of 0.75 MJ m - 2 causing surface melting and of 0.45 MJ m - 2 without melting have been performed in the QSPA-Kh50 plasma accelerator. Analytical considerations allow us to conclude that for both energy deposition values the erosion mechanism is solid dust ejection during surface cracking under the action of thermo-stress. Tungsten influx into the ITER containment of N W ∼5×10 18 W per medium size ELM of 0.75 MJ m - 2 and 0.25 ms time duration has been estimated. The radiation cooling power of P rad =150-300 MW due to such influx of tungsten is intolerable: it should cool the ITER core to 1 keV within a few seconds.

  11. Control of impact loading during distracted running before and after gait retraining in runners.

    Science.gov (United States)

    Cheung, Roy T H; An, Winko W; Au, Ivan P H; Zhang, Janet H; Chan, Zoe Y S; MacPhail, Aislinn J

    2018-07-01

    Gait retraining using visual biofeedback has been reported to reduce impact loading in runners. However, most of the previous studies did not adequately examine the level of motor learning after training, as the modified gait pattern was not tested in a dual-task condition. Hence, this study sought to compare the landing peak positive acceleration (PPA) and vertical loading rates during distracted running before and after gait retraining. Sixteen recreational runners underwent a two-week visual biofeedback gait retraining program for impact loading reduction, with feedback on the PPA measured at heel. In the evaluation of PPA and vertical loading rates before and after the retraining, the participants performed a cognitive and verbal counting task while running. Repeated measures ANOVA indicated a significant interaction between feedback and training on PPA (F = 4.642; P = 0.048) but not vertical loading rates (F > 1.953; P > 0.067). Pairwise comparisons indicated a significantly lower PPA and vertical loading rates after gait retraining (P  0.68). Visual feedback after gait retraining reduced PPA and vertical loading rates during distracted running (P  0.36). Gait retraining is effective in lowering impact loading even when the runners are distracted. In dual-task situation, visual biofeedback provided beneficial influence on kinetics control after gait retraining.

  12. 7 CFR Appendix A to Subpart B of... - Review Rating Summary, RUS Form 300

    Science.gov (United States)

    2010-01-01

    ... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC SYSTEM OPERATIONS AND MAINTENANCE Operations and... Regulators—Rating: ____ b. Sectionalizing Equipment— Rating: ____ c. Distribution Transformers— Rating.... Loading and Load Balance a. Distribution Transformer Loading—Rating:____ b. Load Control Apparatus—Rating...

  13. The relationships between internal and external training load models during basketball training.

    Science.gov (United States)

    Scanlan, Aaron T; Wen, Neal; Tucker, Patrick S; Dalbo, Vincent J

    2014-09-01

    The present investigation described and compared the internal and external training loads during basketball training. Eight semiprofessional male basketball players (mean ± SD, age: 26.3 ± 6.7 years; stature: 188.1 ± 6.2 cm; body mass: 92.0 ± 13.8 kg) were monitored across a 7-week period during the preparatory phase of the annual training plan. A total of 44 total sessions were monitored. Player session ratings of perceived exertion (sRPE), heart rate, and accelerometer data were collected across each training session. Internal training load was determined using the sRPE, training impulse (TRIMP), and summated-heart-rate-zones (SHRZ) training load models. External training load was calculated using an established accelerometer algorithm. Pearson product-moment correlations with 95% confidence intervals (CIs) were used to determine the relationships between internal and external training load models. Significant moderate relationships were observed between external training load and the sRPE (r42 = 0.49, 95% CI = 0.23-0.69, p external training load and the SHRZ model (r42 = 0.61, 95% CI = 0.38-0.77, p internal and external training load models, the magnitude of the correlations and low commonality suggest that internal training load models measure different constructs of the training process than the accelerometer training load model in basketball settings. Basketball coaching and conditioning professionals should not assume a linear dose-response between accelerometer and internal training load models during training and are recommended to combine internal and external approaches when monitoring training load in players.

  14. Tolerance of Artemia to static and shock pressure loading

    Science.gov (United States)

    Fitzmaurice, B. C.; Appleby-Thomas, G. J.; Painter, J. D.; Ono, F.; McMillan, P. F.; Hazael, R.; Meersman, F.

    2017-10-01

    Hydrostatic and hydrodynamic pressure loading has been applied to unicellular organisms for a number of years due to interest from food technology and extremophile communities. There is also an emerging interest in the response of multicellular organisms to high pressure conditions. Artemia salina is one such organism. Previous experiments have shown a marked difference in the hatching rate of these organisms after exposure to different magnitudes of pressure, with hydrostatic tests showing hatching rates at pressures up to several GPa, compared to dynamic loading that resulted in comparatively low survival rates at lower pressure magnitudes. In order to begin to investigate the origin of this difference, the work presented here has focussed on the response of Artemia salina to (quasi) one-dimensional shock loading. Such experiments were carried out using the plate-impact technique in order to create a planar shock front. Artemia cysts were investigated in this manner along with freshly hatched larvae (nauplii). The nauplii and cysts were observed post-shock using optical microscopy to detect motility or hatching, respectively. Hatching rates of 18% were recorded at pressures reaching 1.5 GPa, as determined with the aid of numerical models. Subjecting Artemia to quasi-one-dimensional shock loading offers a way to more thoroughly explore the shock pressure ranges these organisms can survive.

  15. Effects of temperature and organic loading rate on the performance and microbial community of anaerobic co-digestion of waste activated sludge and food waste.

    Science.gov (United States)

    Gou, Chengliu; Yang, Zhaohui; Huang, Jing; Wang, Huiling; Xu, Haiyin; Wang, Like

    2014-06-01

    Anaerobic co-digestion of waste activated sludge and food waste was investigated semi-continuously using continuously stirred tank reactors. Results showed that the performance of co-digestion system was distinctly influenced by temperature and organic loading rate (OLR) in terms of gas production rate (GPR), methane yield, volatile solids (VS) removal efficiency and the system stability. The highest GPR at 55 °C was 1.6 and 1.3 times higher than that at 35 and 45 °C with the OLR of 1 g VSL(-1)d(-1), and the corresponding average CH₄ yields were 0.40, 0.26 and 0.30 L CH₄ g(-1)VSadded, respectively. The thermophilic system exhibited the best load bearing capacity at extremely high OLR of 7 g VSL(-1)d(-1), while the mesophilic system showed the best process stability at low OLRs (< 5 g VSL(-1)d(-1)). Temperature had a more remarkable effect on the richness and diversity of microbial populations than the OLR. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Letterman Army Institute of Research Annual Research Progress Report, FY 1981.

    Science.gov (United States)

    1981-10-01

    five species of mosquitoes. These compounds were tested against sand flies ( Lutzomyia longipalpis), fleas (Xenopsylla cheopis ) and bugs (Rhodnius...BUESCHER, M.D., L.C. RUTLEDGE, R.A. WIRTZ, K.B. GLACKIN, and M.A. MOUSSA. Laboratory tests of repellents against Lutzomyia longipalpis (Diptera

  17. An alternative method for centrifugal compressor loading factor modelling

    Science.gov (United States)

    Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.

    2017-08-01

    The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.

  18. Rate design in a competitive environment

    International Nuclear Information System (INIS)

    Wathen, J.M.

    1995-01-01

    Innovative rate designs used by several United States utilities to become more competitive, were presented. Considerations of retail wheeling and other services for increasing competitiveness were debated. The process for designing specialized rate programs was described, along with descriptions of special rate types, including economic development rates, load retention/anti-bypass rates, cogeneration/self-generation rates, distressed industry rates, load management rates and special situation rates. The existence of special provisions in state legislation allowing special rates to be offered was noted. Confidentiality and the need for a review process to ensure fairness of special agreements was discussed. The efficacy of using individual customer contracts to allow full recognition of the special characteristics and needs of individual customers and the effects of such contracts on the industry, were considered

  19. Load Forecasting in Electric Utility Integrated Resource Planning

    Energy Technology Data Exchange (ETDEWEB)

    Carvallo, Juan Pablo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Larsen, Peter H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sanstad, Alan H [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-07-19

    Integrated resource planning (IRP) is a process used by many vertically-integrated U.S. electric utilities to determine least-cost/risk supply and demand-side resources that meet government policy objectives and future obligations to customers and, in many cases, shareholders. Forecasts of energy and peak demand are a critical component of the IRP process. There have been few, if any, quantitative studies of IRP long-run (planning horizons of two decades) load forecast performance and its relationship to resource planning and actual procurement decisions. In this paper, we evaluate load forecasting methods, assumptions, and outcomes for 12 Western U.S. utilities by examining and comparing plans filed in the early 2000s against recent plans, up to year 2014. We find a convergence in the methods and data sources used. We also find that forecasts in more recent IRPs generally took account of new information, but that there continued to be a systematic over-estimation of load growth rates during the period studied. We compare planned and procured resource expansion against customer load and year-to-year load growth rates, but do not find a direct relationship. Load sensitivities performed in resource plans do not appear to be related to later procurement strategies even in the presence of large forecast errors. These findings suggest that resource procurement decisions may be driven by other factors than customer load growth. Our results have important implications for the integrated resource planning process, namely that load forecast accuracy may not be as important for resource procurement as is generally believed, that load forecast sensitivities could be used to improve the procurement process, and that management of load uncertainty should be prioritized over more complex forecasting techniques.

  20. Infrared thermographic analysis of shape memory polymer during cyclic loading

    International Nuclear Information System (INIS)

    Staszczak, Maria; Pieczyska, Elżbieta A; Maj, Michał; Kukla, Dominik; Tobushi, Hisaaki

    2016-01-01

    In this paper we present the effects of thermomechanical couplings occurring in polyurethane shape memory polymer subjected to cyclic tensile loadings conducted at various strain rates. Stress–strain characteristics were elaborated using a quasistatic testing machine, whereas the specimen temperature changes accompanying the deformation process were obtained with an infrared camera. We demonstrate a tight correlation between the mechanical and thermal results within the initial loading stage. The polymer thermomechanical behaviour in four subsequent loading-unloading cycles and the influence of the strain rate on the stress and the related temperature changes were also examined. In the range of elastic deformation the specimen temperature drops below the initial level due to thermoelastic effect whereas at the higher strains the temperature always increased, due to the dissipative deformation mechanisms. The difference in the characteristics of the specimen temperature has been applied to determine a limit of the polymer reversible deformation and analyzed for various strain rates. It was shown that at the higher strain rates higher values of the stress and temperature changes are obtained, which are related to higher values of the polymer yield points. During the cyclic loading a significant difference between the first and the second cycle was observed. The subsequent loading-unloading cycles demonstrated similar sharply shaped stress and temperature profiles and gradually decrease in values. (paper)

  1. Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 4. Evaluation of other loads and load combinations

    International Nuclear Information System (INIS)

    1984-12-01

    Six topical areas were covered by the Task Group on Other Dynamic Loads and Load Combinations as described below: Event Combinations - dealing with the potential simultaneous occurrence of earthquakes, pipe ruptures, and water hammer events in the piping design basis; Response Combinations - dealing with multiply supported piping with independent inputs, the sequence of combinations between spacial and modal components of response, and the treatment of high frequency modes in combination with low frequency modal responses; Stress Limits/Dynamic Allowables - dealing with inelastic allowables for piping and strain rate effects; Water Hammer Loadings - dealing with code and design specifications for these loadings and procedures for identifying potential water hammer that could affect safety; Relief Valve Opening and Closing Loads - dealing with the adequacy of analytical tools for predicting the effects of these events and, in addition, with estimating effective cycles for fatigue evaluations; and Piping Vibration Loads - dealing with evaluation procedures for estimating other than seismic vibratory loads, the need to consider reciprocating and rotary equipment vibratory loads, and high frequency vibratory loads. NRC staff recommendations or regulatory changes and additional study appear in this report

  2. Temperature rise of cyclicly loaded power cables

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, H

    1984-09-01

    A calculation method for the current ratings of cyclicly loaded power cables is introduced, taking into account optional shapes of the load cycle as well as the drying-out of the soil. The method is based on the Fourier-analysis of the loss cycle, representing an extension of the calculation method of VDE 0298. It is shown, that the ''VDE-method'' gives good results for the thermal resistances, if an ''utility load cycle'' in accordance with VDE 0298 is supposed. Only for cycles deviating essentially from the utility load cycle, the thermal resistances calculated by the ''VDE-method'' may be too great. In these cases the represented method is advantageous and can be processed by the aid of microcomputers.

  3. Strength and behavior in shear of reinforced concrete deep beams under dynamic loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Adhikary, Satadru Das [School of Civil and Environmental Engineering, Nanyang Technological University, 639798 (Singapore); Li, Bing, E-mail: cbli@ntu.edu.sg [School of Civil and Environmental Engineering, Nanyang Technological University, 639798 (Singapore); Fujikake, Kazunori [Department of Civil and Environmental Engineering, National Defense Academy, Yokosuka 239 8686 (Japan)

    2013-06-15

    Highlights: ► Effects of wider range of loading rates on dynamic shear behavior of RC deep beams. ► Experimental investigation of RC deep beam with and without shear reinforcements. ► Verification of experimental results with truss model and FE simulation results. ► Empirical equations are proposed to predict the dynamic increase factor of maximum resistance. -- Abstract: Research on reinforced concrete (RC) deep beams has seen considerable headway over the past three decades; however, information on the dynamic shear strength and behavior of RC deep beams under varying rates of loads remains limited. This paper describes the experimental results of 24 RC deep beams with and without shear reinforcements under varying rates of concentrated loading. Results obtained serve as useful data on shear resistance, failure patterns and strain rates corresponding to varying loading rates. An analytical truss model approach proves its efficacy in predicting the dynamic shear resistance under varying loading rates. Furthermore, three-dimensional nonlinear finite element (FE) model is described and the simulation results are verified with the experimental results. A parametric study is then conducted to investigate the influence of longitudinal reinforcement ratio, transverse reinforcement ratio and shear span to effective depth ratio on shear behavior. Subsequently, two empirical equations were proposed by integrating the various parameters to assess the dynamic increase factor (DIF) of maximum resistance under varying rates of concentrated loading.

  4. Analysis of load monitoring system in hydraulic mobile cranes

    Science.gov (United States)

    Kalairassan, G.; Boopathi, M.; Mohan, Rijo Mathew

    2017-11-01

    Load moment limiters or safe load control systems or are very important in crane safety. The system detects the moment of lifting load and compares this actual moment with the rated moment. The system uses multiple sensors such as boom angle sensor, boom length sensor for telescopic booms, pressure transducers for measuring the load, anti-two block switch and roller switches. The system works both on rubber and on outriggers. The sensors measure the boom extension, boom angle and load to give as inputs to the central processing, which calculate the safe working load range for that particular configuration of the crane and compare it with the predetermined safe load. If the load exceeds the safe load, actions will be taken which will reduce the load moment, which is boom telescopic retraction and boom lifting. Anti-two block switch is used to prevent the two blocking condition. The system is calibrated and load tested for at most precision.

  5. Exfoliation rate of mammary epithelial cells in milk on bovine mastitis caused by Staphylococcus aureus is associated with bacterial load.

    Science.gov (United States)

    Nagasawa, Yuya; Kiku, Yoshio; Sugawara, Kazue; Tanabe, Fuyuko; Hayashi, Tomohito

    2018-01-01

    The exfoliation rate of mammary epithelial cells (MECs) in milk is affected by physiological, breeding and environmental factors. Little is known about the relationship between the MEC exfoliation into milk and mammary-infected Staphylococcus aureus (S. aureus) load on bovine mastitis caused by S. aureus. The aim of this study was to investigate the relationship between S. aureus load and the proportion of MEC exfoliation in milk using five substantial bovine mastitis models. In 64 randomly extracted milk samples from udders at 3-21 days after S. aureus infusion, there were various samples with different numbers of S. aureus counts and somatic cell counts. No significant correlations were found between the S. aureus counts and somatic cell count (r = 0.338). In contrast, a significant correlation was noted between S. aureus counts and the proportion of cytokeratin-positive cells in the milk from the infused udders (r = 0.734, P mastitis udders caused by S. aureus may contribute to reduced milk yield. © 2017 Japanese Society of Animal Science.

  6. Initial foot contact and related kinematics affect impact loading rate in running.

    Science.gov (United States)

    Breine, Bastiaan; Malcolm, Philippe; Van Caekenberghe, Ine; Fiers, Pieter; Frederick, Edward C; De Clercq, Dirk

    2017-08-01

    This study assessed kinematic differences between different foot strike patterns and their relationship with peak vertical instantaneous loading rate (VILR) of the ground reaction force (GRF). Fifty-two runners ran at 3.2 m · s -1 while we recorded GRF and lower limb kinematics and determined foot strike pattern: Typical or Atypical rearfoot strike (RFS), midfoot strike (MFS) of forefoot strike (FFS). Typical RFS had longer contact times and a lower leg stiffness than Atypical RFS and MFS. Typical RFS showed a dorsiflexed ankle (7.2 ± 3.5°) and positive foot angle (20.4 ± 4.8°) at initial contact while MFS showed a plantar flexed ankle (-10.4 ± 6.3°) and more horizontal foot (1.6 ± 3.1°). Atypical RFS showed a plantar flexed ankle (-3.1 ± 4.4°) and a small foot angle (7.0 ± 5.1°) at initial contact and had the highest VILR. For the RFS (Typical and Atypical RFS), foot angle at initial contact showed the highest correlation with VILR (r = -0.68). The observed higher VILR in Atypical RFS could be related to both ankle and foot kinematics and global running style that indicate a limited use of known kinematic impact absorbing "strategies" such as initial ankle dorsiflexion in MFS or initial ankle plantar flexion in Typical RFS.

  7. Tissue loading created during spinal manipulation in comparison to loading created by passive spinal movements.

    Science.gov (United States)

    Funabashi, Martha; Kawchuk, Gregory N; Vette, Albert H; Goldsmith, Peter; Prasad, Narasimha

    2016-12-01

    Spinal manipulative therapy (SMT) creates health benefits for some while for others, no benefit or even adverse events. Understanding these differential responses is important to optimize patient care and safety. Toward this, characterizing how loads created by SMT relate to those created by typical motions is fundamental. Using robotic testing, it is now possible to make these comparisons to determine if SMT generates unique loading scenarios. In 12 porcine cadavers, SMT and passive motions were applied to the L3/L4 segment and the resulting kinematics tracked. The L3/L4 segment was removed, mounted in a parallel robot and kinematics of SMT and passive movements replayed robotically. The resulting forces experienced by L3/L4 were collected. Overall, SMT created both significantly greater and smaller loads compared to passive motions, with SMT generating greater anterioposterior peak force (the direction of force application) compared to all passive motions. In some comparisons, SMT did not create significantly different loads in the intact specimen, but did so in specific spinal tissues. Despite methodological differences between studies, SMT forces and loading rates fell below published injury values. Future studies are warranted to understand if loading scenarios unique to SMT confer its differential therapeutic effects.

  8. The Effect of Loading Rate on Hydraulic Fracturing in Synthetic Granite - a Discrete Element Study

    Science.gov (United States)

    Tomac, I.; Gutierrez, M.

    2015-12-01

    rock plays a significant role in fracture propagation velocity. Fluid viscosity effects are similar to the loading rate effects, because in both cases the rapid buildup of the pressure in the wellbore in absence of the inflow of the fluid into initiated fracture causes induction of multiple simultaneous fracture branches at the wellbore wall.

  9. Energy efficiency analysis of reconfigured distribution system for practical loads

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2016-09-01

    Full Text Available In deregulated rate structure, the performance evaluation of distribution system for energy efficiency includes; loss minimization, improved power quality, loadability limit, reliability and availability of supply. Energy efficiency changes with the variation in loading pattern and the load behaviour. Further, the nature of load at each node is not explicitly of any one type rather their characteristics depend upon the node voltages. In most cases, load is assumed to be constant power (real and reactive. In this paper voltage dependent practical loads are represented with composite load model and the energy efficiency performance of distribution system for practical loads is evaluated in different configurations of 33-node system.

  10. The Influence of External Load on Quadriceps Muscle and Tendon Dynamics during Jumping.

    Science.gov (United States)

    Earp, Jacob E; Newton, Robert U; Cormie, Prue; Blazevich, Anthony J

    2017-11-01

    Tendons possess both viscous (rate-dependent) and elastic (rate-independent) properties that determine tendon function. During high-speed movements external loading increases both the magnitude (FT) and rate (RFDT) of tendon loading. The influence of external loading on muscle and tendon dynamics during maximal vertical jumping was explored. Ten resistance-trained men performed parallel-depth, countermovement vertical jumps with and without additional load (0%, 30%, 60%, and 90% of maximum squat lift strength), while joint kinetics and kinematics, quadriceps tendon length (LT) and patellar tendon FT and RFDT were estimated using integrated ultrasound, motion analysis and force platform data and muscle tendon modelling. Estimated FT and RFDT, but not peak LT, increased with external loading. Temporal comparisons between 0% and 90% loads revealed that FT was greater with 90% loading throughout the majority of the movement (11%-81% and 87%-95% movement duration). However, RFDT was greater with 90% load only during the early movement initiation phase (8%-15% movement duration) but was greater in the 0% load condition later in the eccentric phase (27%-38% movement duration). LT was longer during the early movement (12%-23% movement duration) but shorter in the late eccentric and early concentric phases (48%-55% movement duration) with 90% load. External loading positively influenced peak FT and RFDT but tendon strain appeared unaffected, suggesting no additive effect of external loading on patellar tendon lengthening during human jumping. Temporal analysis revealed that external loading resulted in a large initial RFDT that may have caused dynamic stiffening of the tendon and attenuated tendon strain throughout the movement. These results suggest that external loading influences tendon lengthening in both a load- and movement-dependent manner.

  11. Improvement of daily load-following operation for boiling water reactors

    International Nuclear Information System (INIS)

    Kiguchi, Takashi; Kurihara, Kunitoshi; Sakurai, Mikio; Joge, Toshio; Asami, Kazuo.

    1980-01-01

    Recently, with the increase of the proportion of nuclear power generation to the total amount of power generation of electric power systems, the needs of daily load-following operation of nuclear power stations have heightened, accordingly the study on the method of daily load-following operation has been carried out for BWRs. In this study, by the combined use of the flow rate control of core coolnat being operated easily and the operation of control rods, the BWR system with the daily load-following performance of 100% power output in daytime and 50% power output at night was the target of development. For the purpose, the change of core characteristics during load-following was grasped analytically, and the range of load change was investigated. At the same time, as the first stage of developing operation control and monitoring system, the reactor output-adjusting device which makes generator output automatically follow the target load change pattern by the flow rate control of core coolnat, and the equipment for monitoring core performance on line were developed. The analysis of the method of daily load-following operation in present-day BWRs, the study on the improvement of load-following operation performance, the reactor output-adjusting device are described. (Kako, I.)

  12. Influence of organic load rate (OLR) on the hydrolytic acidification of 2-butenal manufacture wastewater and analysis of bacterial community structure.

    Science.gov (United States)

    Song, Guangqing; Xi, Hongbo; Zhou, Yuexi; Fu, Liya; Xing, Xin; Wu, Changyong

    2017-11-01

    The influence of organic loading rate (OLR) on the performance of hydrolytic acidification process for treating 2-butenal manufacture wastewater was comprehensively studied, while its impact on microbial community was thoroughly investigated. The results demonstrated that over 21.0% of the average COD removal rate was observed in the range of OLR from 0.52 to 3.98g COD/L·d, whereas it reduced to 15.3% with increasing OLR to 6.09g COD/L·d. The acidification degree dramatically decreased from 17.1% to 4.7% when OLR increased from 3.98 to 6.09g COD/L·d. In addition, the removal rates of three kinds of typical matters were less than 65% at the OLR 6.09g COD/L·d. Illumina MiSeq sequencing revealed that Proteobacteria, Chloroflexi, Firmicutes, and Bacteroidetes were dominant phyla at different OLRs. Finally, multivariate analysis suggested that the genera Longilinea and T78 had a positive correlation with the degradation of three kinds of typical matters and COD removal rates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Experimental study of a macrocrack propagation in a concrete specimen subjected to creep loading

    Science.gov (United States)

    Rossi, P.; Boulay, C.; Tailhan, J.-L.; Martin, E.

    2013-07-01

    Structures managers need a better prediction of the delayed failure of concrete structures, especially for very important structures like nuclear power plant encasement. Sustained loadings at high level (above 75% of loading capacity of the structure), can lead to structure failure after some time. In this study, a series of 4-point bending tests were performed in order to characterize the creep behaviour of pre-cracked beams under high load level. The specimens were made of normal strength concrete. A power law relationship is observed between the secondary deflection creep rate and the failure time. It is also shown that when crack propagation occurs during the creep loading, the creep deflection rate increases with the creep loading level and with the crack propagation rate.

  14. Prediction of Spring Rate and Initial Failure Load due to Material Properties of Composite Leaf Spring

    International Nuclear Information System (INIS)

    Oh, Sung Ha; Choi, Bok Lok

    2014-01-01

    This paper presented analysis methods for adapting E-glass fiber/epoxy composite (GFRP) materials to an automotive leaf spring. It focused on the static behaviors of the leaf spring due to the material composition and its fiber orientation. The material properties of the GFRP composite were directly measured based on the ASTM standard test. A reverse implementation was performed to obtain the complete set of in-situ fiber and matrix properties from the ply test results. Next, the spring rates of the composite leaf spring were examined according to the variation of material parameters such as the fiber angles and resin contents of the composite material. Finally, progressive failure analysis was conducted to identify the initial failure load by means of an elastic stress analysis and specific damage criteria. As a result, it was found that damage first occurred along the edge of the leaf spring owing to the shear stresses

  15. Load-induced modulation of signal transduction networks.

    Science.gov (United States)

    Jiang, Peng; Ventura, Alejandra C; Sontag, Eduardo D; Merajver, Sofia D; Ninfa, Alexander J; Del Vecchio, Domitilla

    2011-10-11

    Biological signal transduction networks are commonly viewed as circuits that pass along information--in the process amplifying signals, enhancing sensitivity, or performing other signal-processing tasks--to transcriptional and other components. Here, we report on a "reverse-causality" phenomenon, which we call load-induced modulation. Through a combination of analytical and experimental tools, we discovered that signaling was modulated, in a surprising way, by downstream targets that receive the signal and, in doing so, apply what in physics is called a load. Specifically, we found that non-intuitive changes in response dynamics occurred for a covalent modification cycle when load was present. Loading altered the response time of a system, depending on whether the activity of one of the enzymes was maximal and the other was operating at its minimal rate or whether both enzymes were operating at submaximal rates. These two conditions, which we call "limit regime" and "intermediate regime," were associated with increased or decreased response times, respectively. The bandwidth, the range of frequency in which the system can process information, decreased in the presence of load, suggesting that downstream targets participate in establishing a balance between noise-filtering capabilities and a circuit's ability to process high-frequency stimulation. Nodes in a signaling network are not independent relay devices, but rather are modulated by their downstream targets.

  16. Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis.

    Science.gov (United States)

    Papaspyridakos, Panos; Chen, Chun-Jung; Chuang, Sung-Kiang; Weber, Hans-Peter

    2014-01-01

    To report on the effect of immediate implant loading with fixed prostheses compared to early and conventional loading on implant and prosthesis survival, failure, and complications. An electronic and manual search was conducted to identify randomized controlled clinical trials (RCTs) as well as prospective and retrospective studies involving rough surface implants and implant fixed complete dental prostheses for edentulous patients. The 62 studies that fulfilled the inclusion criteria featured 4 RCTs, 2 prospective case-control studies, 34 prospective cohort studies, and 22 retrospective cohort studies. These studies yielded data from 2,695 patients (2,757 edentulous arches) with 13,653 implants. Studies were grouped according to the loading protocol applied; 45 studies reported on immediate loading, 8 on early loading, and 11 on conventional loading. For the immediate loading protocol with flap surgery, the implant and prosthesis survival rates ranged from 90.1% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). When immediate loading was combined with guided flapless implant placement, the implant survival rates ranged from 90% to 99.4%. For the early loading protocol, the implant and prosthesis survival rates ranged from 94.74% to 100% and 93.75% to 100%, respectively (range of follow-up, 1 to 10 years). For the conventional loading protocol, the implant and prosthesis survival rates ranged from 94.95% to 100% and 87.5% to 100%, respectively (range of follow-up, 2 to 15 years). No difference was identified between maxilla and mandible. When selecting cases carefully and using dental implants with a rough surface, immediate loading with fixed prostheses in edentulous patients results in similar implant and prosthesis survival and failure rates as early and conventional loading. For immediate loading, most of the studies recommended a minimal insertion torque of 30 Ncm. The estimated 1-year implant survival was above 99% with all three

  17. Increasing Running Step Rate Reduces Patellofemoral Joint Forces

    Science.gov (United States)

    Lenhart, Rachel L.; Thelen, Darryl G.; Wille, Christa M.; Chumanov, Elizabeth S.; Heiderscheit, Bryan C.

    2013-01-01

    Purpose Increasing step rate has been shown to elicit changes in joint kinematics and kinetics during running, and has been suggested as a possible rehabilitation strategy for runners with patellofemoral pain. The purpose of this study was to determine how altering step rate affects internal muscle forces and patellofemoral joint loads, and then to determine what kinematic and kinetic factors best predict changes in joint loading. Methods We recorded whole body kinematics of 30 healthy adults running on an instrumented treadmill at three step rate conditions (90%, 100%, and 110% of preferred step rate). We then used a 3D lower extremity musculoskeletal model to estimate muscle, patellar tendon, and patellofemoral joint forces throughout the running gait cycles. Additionally, linear regression analysis allowed us to ascertain the relative influence of limb posture and external loads on patellofemoral joint force. Results Increasing step rate to 110% of preferred reduced peak patellofemoral joint force by 14%. Peak muscle forces were also altered as a result of the increased step rate with hip, knee and ankle extensor forces, and hip abductor forces all reduced in mid-stance. Compared to the 90% step rate condition, there was a concomitant increase in peak rectus femoris and hamstring loads during early and late swing, respectively, at higher step rates. Peak stance phase knee flexion decreased with increasing step rate, and was found to be the most important predictor of the reduction in patellofemoral joint loading. Conclusion Increasing step rate is an effective strategy to reduce patellofemoral joint forces and could be effective in modulating biomechanical factors that can contribute to patellofemoral pain. PMID:23917470

  18. Different organic loading rates on the biogas production during the anaerobic digestion of rice straw: A pilot study.

    Science.gov (United States)

    Zhou, Jun; Yang, Jun; Yu, Qing; Yong, Xiaoyu; Xie, Xinxin; Zhang, Lijuan; Wei, Ping; Jia, Honghua

    2017-11-01

    The aim of this work was to investigate the mesophilic methane fermentation of rice straw at different organic loading rates (OLRs) in a 300m 3 bioreactor. It was found that biogas production increased when the OLR was below 2.00kg VS substrate /(m 3 ·d). The average volumetric biogas production reached 0.86m 3 /(m 3 ·d) at an OLR of 2.00kg VS substrate /(m 3 ·d). Biogas production rate was 323m 3 /t dry rice straw over the whole process. The pH, chemical oxygen demand, volatile fatty acid, and NH 4 + -N concentrations were all in optimal range at different OLRs. High-throughput sequencing analysis indicated that Firmicutes, Fibrobacteres, and Spirochaetes predominated in straw samples. Chloroflexi, Proteobacteria, and Planctomycetes were more abundant in the slurry. The hydrogenotrophic pathway was the main biochemical pathway of methanogenesis in the reactor. This study provides new information regarding the OLR and the differences in the spatial distribution of specific microbiota in a rice straw biogas plant. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Biogas-pH automation control strategy for optimizing organic loading rate of anaerobic membrane bioreactor treating high COD wastewater.

    Science.gov (United States)

    Yu, Dawei; Liu, Jibao; Sui, Qianwen; Wei, Yuansong

    2016-03-01

    Control of organic loading rate (OLR) is essential for anaerobic digestion treating high COD wastewater, which would cause operation failure by overload or less efficiency by underload. A novel biogas-pH automation control strategy using the combined gas-liquor phase monitoring was developed for an anaerobic membrane bioreactor (AnMBR) treating high COD (27.53 g·L(-1)) starch wastewater. The biogas-pH strategy was proceeded with threshold between biogas production rate >98 Nml·h(-1) preventing overload and pH>7.4 preventing underload, which were determined by methane production kinetics and pH titration of methanogenesis slurry, respectively. The OLR and the effluent COD were doubled as 11.81 kgCOD·kgVSS(-1)·d(-1) and halved as 253.4 mg·L(-1), respectively, comparing with a constant OLR control strategy. Meanwhile COD removal rate, biogas yield and methane concentration were synchronously improved to 99.1%, 312 Nml·gCODin(-1) and 74%, respectively. Using the biogas-pH strategy, AnMBR formed a "pH self-regulation ternary buffer system" which seizes carbon dioxide and hence provides sufficient buffering capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Survival rates and bone loss after immediate loading of implants in fresh extraction sockets (single gaps). A clinical prospective study with 4 year follow-up

    Science.gov (United States)

    Wojtovicz, Eduardo; España-Lopez, Antonio; Jimenez-Guerra, Alvaro; Monsalve-Guil, Loreto; Ortiz-Garcia, Ivan; Serrera-Figallo, Maria-Angeles

    2018-01-01

    Background The aim of this prospective study was to report the outcome of treatment with implants inserted after tooth extraction and immediately loaded. Material and Methods Fifty-six patients with single tooth loss were treated with 116 IPX Galimplant® implants with internal connections and a sandblasted, acid-etched surface. All implants were placed after tooth extraction using a flapless approach without bone regeneration, and they were then immediately loaded with cemented acrylic prostheses. After a period of three months, definitive cemented ceramic prostheses were placed. Patients were examined throughout a total of 4 years of follow-up. Marginal bone loss and survival rates were evaluated using digital periapical radiographs, taking into account clinical variables such as age, gender, smoking, history of periodontitis, etiology of extraction, placement site, diameter, and implant length. The Mann-Whitney U and Kruskal-Wallis non-parametric tests were used to compare differences between subgroups created based on the different clinical variables identified. Results Clinical results indicate an implant survival and success rate of 97.4%. Three implants were lost. Of the 116 immediate acrylic single crowns initially placed, 113 were replaced with definitive ceramic crowns after 3 months. A total of 77.8% of implants were inserted in the maxilla, while 22.2% were inserted in the mandible. No further complications were reported after the follow-up period (4 years). The mean marginal bone loss was 0.67 mm ± 0.40 mm. No differences were found among the subgroups of study patients. Conclusions This study indicates that dental implants that are inserted after tooth extraction and immediately loaded may constitute a successful and predictable alternative implant treatment. Key words:Dental implants, post-extraction implants, fresh sockets, immediate loading, immediate prostheses, implant dentistry. PMID:29476669

  1. Estimation of structural reliability under combined loads

    International Nuclear Information System (INIS)

    Shinozuka, M.; Kako, T.; Hwang, H.; Brown, P.; Reich, M.

    1983-01-01

    For the overall safety evaluation of seismic category I structures subjected to various load combinations, a quantitative measure of the structural reliability in terms of a limit state probability can be conveniently used. For this purpose, the reliability analysis method for dynamic loads, which has recently been developed by the authors, was combined with the existing standard reliability analysis procedure for static and quasi-static loads. The significant parameters that enter into the analysis are: the rate at which each load (dead load, accidental internal pressure, earthquake, etc.) will occur, its duration and intensity. All these parameters are basically random variables for most of the loads to be considered. For dynamic loads, the overall intensity is usually characterized not only by their dynamic components but also by their static components. The structure considered in the present paper is a reinforced concrete containment structure subjected to various static and dynamic loads such as dead loads, accidental pressure, earthquake acceleration, etc. Computations are performed to evaluate the limit state probabilities under each load combination separately and also under all possible combinations of such loads. Indeed, depending on the limit state condition to be specified, these limit state probabilities can indicate which particular load combination provides the dominant contribution to the overall limit state probability. On the other hand, some of the load combinations contribute very little to the overall limit state probability. These observations provide insight into the complex problem of which load combinations must be considered for design, for which limit states and at what level of limit state probabilities. (orig.)

  2. Radiation preparation of drug carriers based on poly(N-isopropylacrylamide) hydrogels, their loading capacities and controlled release rates for dexamethasone and tegafur

    International Nuclear Information System (INIS)

    Hoang Dang Sang; Nguyen Van Binh; Tran Bang Diep; Nguyen Thi Thom; Hoang Phuong Thao; Pham Duy Duong; Tran Minh Quynh

    2015-01-01

    Thermo-sensitive hydrogels have great potential in some applications. In order to use as the drug delivery systems, the hydrogels should be biocompatibility. New polymers with more biocompatibility and better biodegradability, and environmental friendly crosslinking agents would be necessary for the successful drug carriers. Poly (N-isopropylacrylamide-co-dimethylacrylamide) based hydrogels have been prepared from the admixture solutions of N-isopropylacrylamide (NIPA) and N,N’-dimethyl acrylamide (DMA) by radiation copolymerization and crosslinking at radiation dose of 20 kGy as reported in our previous study. Water swelling behaviour of the resulting hydrogels were much depended on their nature such as initial ratio of NIPA and DMA. The drug-loaded hydrogels were prepared by merging hydrogel in the solutions containing corresponding drugs. Loading capacity of the hydrogels were about 48.6 and 95.7 mg per g dried hydrogel for dexamethasone and tegafur. The release studies showed that the presence of ions in simulated body fluid and temperature of the solution much affecting to in vitro release behaviors of hydrogels for dexamethasone and tegafur. The release rates were fast for both drug models. The result also revealed that these drug carriers were biocompatibility without skin irritation, suggested the drug-loaded hydrogels may be used as controlled release drug delivery systems. (author)

  3. A simplified model of dynamic interior cooling load evaluation for office buildings

    International Nuclear Information System (INIS)

    Ding, Yan; Zhang, Qiang; Wang, Zhaoxia; Liu, Min; He, Qing

    2016-01-01

    Highlights: • The core interior disturbance was determined by principle component analysis. • Influences of occupants on cooling load should be described using time series. • A simplified model was built to evaluate dynamic interior building cooling load. - Abstract: Predicted cooling load is a valuable tool for assessing the operation of air-conditioning systems. Compared with exterior cooling load, interior cooling load is more unpredictable. According to principle components analysis, occupancy was proved to be a typical factor influencing interior cooling loads in buildings. By exploring the regularity of interior disturbances in an office building, a simplified evaluation model for interior cooling load was established in this paper. The stochastic occupancy rate was represented by a Markov transition model. Equipment power, lighting power and fresh air were all related to occupancy rate based on time sequence. The superposition of different types of interior cooling loads was also considered in the evaluation model. The error between the evaluation results and measurement results was found to be lower than 10%. In reference to the cooling loads calculated by the traditional design method and area-based method in case study office rooms, the evaluated cooling loads were suitable for operation regulation.

  4. Creep crack growth by grain boundary cavitation under monotonic and cyclic loading

    Science.gov (United States)

    Wen, Jian-Feng; Srivastava, Ankit; Benzerga, Amine; Tu, Shan-Tung; Needleman, Alan

    2017-11-01

    Plane strain finite deformation finite element calculations of mode I crack growth under small scale creep conditions are carried out. Attention is confined to isothermal conditions and two time histories of the applied stress intensity factor: (i) a monononic increase to a plateau value subsequently held fixed; and (ii) a cyclic time variation. The crack growth calculations are based on a micromechanics constitutive relation that couples creep deformation and damage due to grain boundary cavitation. Grain boundary cavitation, with cavity growth due to both creep and diffusion, is taken as the sole failure mechanism contributing to crack growth. The influence on the crack growth rate of loading history parameters, such as the magnitude of the applied stress intensity factor, the ratio of the applied minimum to maximum stress intensity factors, the loading rate, the hold time and the cyclic loading frequency, are explored. The crack growth rate under cyclic loading conditions is found to be greater than under monotonic creep loading with the plateau applied stress intensity factor equal to its maximum value under cyclic loading conditions. Several features of the crack growth behavior observed in creep-fatigue tests naturally emerge, for example, a Paris law type relation is obtained for cyclic loading.

  5. Characterization and prediction of rate-dependent flexibility in lumbar spine biomechanics at room and body temperature.

    Science.gov (United States)

    Stolworthy, Dean K; Zirbel, Shannon A; Howell, Larry L; Samuels, Marina; Bowden, Anton E

    2014-05-01

    The soft tissues of the spine exhibit sensitivity to strain-rate and temperature, yet current knowledge of spine biomechanics is derived from cadaveric testing conducted at room temperature at very slow, quasi-static rates. The primary objective of this study was to characterize the change in segmental flexibility of cadaveric lumbar spine segments with respect to multiple loading rates within the range of physiologic motion by using specimens at body or room temperature. The secondary objective was to develop a predictive model of spine flexibility across the voluntary range of loading rates. This in vitro study examines rate- and temperature-dependent viscoelasticity of the human lumbar cadaveric spine. Repeated flexibility tests were performed on 21 lumbar function spinal units (FSUs) in flexion-extension with the use of 11 distinct voluntary loading rates at body or room temperature. Furthermore, six lumbar FSUs were loaded in axial rotation, flexion-extension, and lateral bending at both body and room temperature via a stepwise, quasi-static loading protocol. All FSUs were also loaded using a control loading test with a continuous-speed loading-rate of 1-deg/sec. The viscoelastic torque-rotation response for each spinal segment was recorded. A predictive model was developed to accurately estimate spine segment flexibility at any voluntary loading rate based on measured flexibility at a single loading rate. Stepwise loading exhibited the greatest segmental range of motion (ROM) in all loading directions. As loading rate increased, segmental ROM decreased, whereas segmental stiffness and hysteresis both increased; however, the neutral zone remained constant. Continuous-speed tests showed that segmental stiffness and hysteresis are dependent variables to ROM at voluntary loading rates in flexion-extension. To predict the torque-rotation response at different loading rates, the model requires knowledge of the segmental flexibility at a single rate and specified

  6. Left ventricular twist is load-dependent as shown in a large animal model with controlled cardiac load

    Directory of Open Access Journals (Sweden)

    A’roch Roman

    2012-06-01

    Full Text Available Abstract Background Left ventricular rotation and twist can be assessed noninvasively by speckle tracking echocardiography. We sought to characterize the effects of acute load change and change in inotropic state on rotation parameters as a measure of left ventricular (LV contractility. Methods Seven anesthetised juvenile pigs were studied, using direct measurement of left ventricular pressure and volume and simultaneous transthoracic echocardiography. Transient inflation of an inferior vena cava balloon (IVCB catheter produced controlled load reduction. First and last beats in the sequence of eight were analysed with speckle tracking (STE during the load alteration and analysed for change in rotation/twist during controlled load alteration at same contractile status. Two pharmacological inotropic interventions were also included to examine the same hypothesis in additionally conditions of increased and decreased myocardial contractility in each animal. Paired comparisons were made for different load states using the Wilcoxon’s Signed Rank test. Results The inferior vena cava balloon occlusion (IVCBO load change compared for first to last beat resulted in LV twist increase (11.67° ±2.65° vs. 16.17° ±3.56° respectively, p  Conclusions Peak systolic LV twist and peak early diastolic untwisting rate are load dependent. Differences in LV load should be included in the interpretation when serial measures of twist are compared.

  7. Optimizing the Loads of multi-player online game Servers using Markov Chains

    DEFF Research Database (Denmark)

    Saeed, Aamir; Olsen, Rasmus Løvenstein; Pedersen, Jens Myrup

    2015-01-01

    that is created due to the load balancing of servers. Load balancing among servers is sensitive to correct status information. The Markov based load prediction was introduced in this paper to predict load of under-loaded servers, based on arrival (μ) and departure (λ) rates of players. The prediction based...... that need to be considered when developing load balancing algorithm, that is the reliability of the information that is shared. Simulation results show that Markov based prediction of load information performed better from the normal load status information sharing....

  8. Performance of a constructed wetland treating intensive shrimp aquaculture wastewater under high hydraulic loading rate

    International Nuclear Information System (INIS)

    Lin, Y.-F.; Jing, S.-R.; Lee, D.-Y.; Chang, Y.-F.; Chen, Y.-M.; Shih, K.-C.

    2005-01-01

    A water treatment unit, mainly consisting of free water surface (FWS) and subsurface flow (SF) constructed wetland cells, was integrated into a commercial-scale recirculating aquaculture system for intensive shrimp culture. This study investigated performance of the treatment wetlands for controlling water quality. The results showed that the FWS-SF cells effectively removed total suspended solids (55-66%), 5-day biochemical oxygen demand (37-54%), total ammonia (64-66%) and nitrite (83-94%) from the recirculating water under high hydraulic loading rates (1.57-1.95 m/day). This led to a water quality that was suitable for shrimp culture and effluent that always satisfied the discharge standards. The area ratios of wetlands to culture tank being demonstrated (0.43) and calculated (0.096) in this study were both significantly lower than the reported values. Accordingly, a constructed wetland was technically and economically feasible for managing water quality of an intensive aquaculture system. - A constructed wetland was found to be technically and economically feasible for managing water quality of an intensive recirculating aquaculture system

  9. Anaerobic digestion of grain stillage at high organic loading rates in three different reactor systems

    International Nuclear Information System (INIS)

    Schmidt, Thomas; Pröter, Jürgen; Scholwin, Frank; Nelles, Michael

    2013-01-01

    In this study the anaerobic digestion of grain stillage in three different reactor systems (continuous stirred tank reactor, anaerobic sequencing batch reactor, fixed bed reactor) with and without immobilization of microorganisms was investigated to evaluate the performance during increase of the organic loading rate (OLR) from 1 to 10 g of volatile solids (VS) per liter reactor volume and day and decrease of the hydraulic retention time (HRT) from 40 to 6 days. No significant differences have been observed between the performances of the three examined reactor systems. The changes in OLR and HRT caused a reduction of the specific biogas production (SBP) of about 25% from about 650 to 550 L kg −1 of VS but would also diminish the necessary digester volume and investment costs of about 75% compared to the state of the art. -- Highlights: ► It was shown that without immobilization of microorganisms low HRT's are possible. ► No significant differences have been observed between different digester designs. ► Trace element supplementation is obligatory with grain stillage as substrate

  10. Effects of organic loading rate on biogas production from macroalgae: Performance and microbial community structure.

    Science.gov (United States)

    Sun, Meng-Ting; Fan, Xiao-Lei; Zhao, Xiao-Xian; Fu, Shan-Fei; He, Shuai; Manasa, M R K; Guo, Rong-Bo

    2017-07-01

    Macroalgae biomass has been considered as a promising feedstock for biogas production. In order to improve the efficiency of anaerobic digestion (AD) of macroalgae, semi-continuous fermentation was conducted to examine the effects of organic loading rate (OLR) on biogas production from Macrocystis pyrifer. Results showed that, under OLRs of 1.37, 2.74, 4.12 and 6.85kgVS substrate /(m 3 ·d), the average unit biogas yields were 438.9, 477.3, 480.1 and 188.7mL/(gVS substrate d), respectively. It indicated that biogas production was promoted by the increased OLR in an appropriate range while inhibited by the OLR beyond the appropriate range. The investigation on physical-chemical parameters revealed that unfavorable VFAs concentration, pH and salinity might be the main causes for system failure due to the overrange OLR, while the total phenols failed to reach the inhibitory concentration. Microbial community analysis demonstrated that several bacterial and archaeal phyla altered with increase in OLR apparently. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Experimental control of the solvent load of inductively coupled argon plasmas and effects of the chloroform plasma load on their analytical performance

    Science.gov (United States)

    Maessen, F. J. M. J.; Kreuning, G.; Balke, J.

    The solvent plasma load ( QSPL) of water, methanol and chloroform was established as a function of the liquid uptake rate ( QL) by using a continuous weighing method for recording the rate differences between the relevant liquid streams. The shape of the QL vs QSPL curves revealed that the liquid uptake rate is a parameter much too insensitive to serve as a criterion for assessing the stability of "organic" plasmas. The quantity "maximum tolerable solvent plasma load" is suggested as a more useful criterion. Effects of rf power, observation height and solvent plasma load on the properties of chloroform inductively coupled plasmas (ICPs) are reported. The measurement of the axial distribution of net line intensities of representative spectral lines showed that the behaviour of emission lines as to their "hardness" is essentially the same in ICPs loaded with chloroform or water. The chloroform plasma load was regulated by the use of a condenser of which the temperature was varied in a range between -50°C and +20°C. Analytical performance characteristics such as net line and background intensities, signal-to-background ratios, and relative standard deviations of the background signal are presented for ICPs with various chloroform loads. Two sets of experimental conditions were finally selected for simultaneous multielement analysis of chloroform solvent solutions, one with and one without aerosol cooling. In the case that aerosol cooling was applied, the detection limits were similar to those for aqueous plasmas. Without aerosol cooling the detection limits were up to an order of magnitude poorer. An attempt has been made to catagorize organic solvents on the basis of both volatility and their behaviour in ICP systems. For a better understanding of the consequences of solvent volatility in ICP-AES it is of importance to consider separately the properties that determine the volatility of liquids, viz. the evaporation rate and the saturation vapour pressure.

  12. [SATLC- INITIATIVE] USES OF SATL & MULTIPLE INTELLIGENCES ...

    African Journals Online (AJOL)

    Preferred Customer

    concepts without emphasizing conceptual understanding (2, 3). ... approach that combines and uses features and ideas from systemics and constructivism adjusted in concept ... stage of the secondary level and the first year general chemistry of tertiary level. .... From Piaget to the present, Basic Books, London: Rutledge. 8.

  13. ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings

    NARCIS (Netherlands)

    Drachsler, Hendrik; Pecceu, Dries; Arts, Tanja; Hutten, Edwin; Rutledge, Lloyd; Van Rosmalen, Peter; Hummel, Hans; Koper, Rob

    2009-01-01

    Drachsler, H., Peccau, D., Arts, T., Hutten, E., Rutledge, L., Van Rosmalen, P., Hummel, H. G. K., & Koper, R. (2009). ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings. Presentation at the 2nd Workshop Mash-Up Personal Learning

  14. Comparing groundwater recharge and base flow in the Bukmoongol ...

    Indian Academy of Sciences (India)

    model, also known as the Rorabaugh Method. (Rorabaugh 1960; Daniel 1976; Rutledge 2007b), estimates groundwater recharges for each stream- flow peak using the recession-curve-displacement method. It is based on an analytical model that describes groundwater discharge subsequent to recharge to the water table ...

  15. PPOOLEX experiments on dynamic loading with pressure feedback

    International Nuclear Information System (INIS)

    Puustinen, M.; Laine, J.; Raesaenen, A.

    2011-01-01

    This report summarizes the results of the dynamic loading experiments (DYN series) carried out with the scaled down, two compartment PPOOLEX test facility designed and constructed at LUT. Steam was blown into the dry well compartment and from there through the DN200 vertical blowdown pipe to the condensation pool filled with sub-cooled water. The main purpose of the experiments was to study dynamic loads caused by different condensation modes. Particularly, the effect of counterpressure on loads due to pressure oscillations induced by chugging was of interest. Before the experiments the condensation pool was filled with isothermal water so that the blowdown pipe outlet was submerged by 1.03-1.11 m. The initial temperature of the pool water varied from 11 deg. C to 63 deg. C, the steam flow rate from 290 g/s to 1220 g/s and the temperature of incoming steam from 132 deg. C to 182 deg. C. Non-condensables were pushed from the dry well into the gas space of the wet well with a short discharge of steam before the recorded period of the experiments. As a result of this procedure, the system pressure was at an elevated level in the beginning of the actual experiments. An increased counterpressure was used in the last experiment of the series. The diminishing effect of increased system pressure on chugging intensity and on measured loads is evident from the results of the last experiment. The highest pressure pulses both inside the blowdown pipe and in the condensation pool were about half of those measured with a lower system pressure but otherwise with similar test parameters. The experiments on dynamic loading gave expected results. The loads experienced by pool structures depended strongly on the steam mass flow rate, pool water temperature and system pressure. The DYN experiments indicated that chugging and condensation within the blowdown pipe cause significant dynamic loads in case of strongly sub-cooled pool water. The level of pool water temperature is decisive

  16. PPOOLEX experiments on dynamic loading with pressure feedback

    Energy Technology Data Exchange (ETDEWEB)

    Puustinen, M.; Laine, J.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2011-01-15

    This report summarizes the results of the dynamic loading experiments (DYN series) carried out with the scaled down, two compartment PPOOLEX test facility designed and constructed at LUT. Steam was blown into the dry well compartment and from there through the DN200 vertical blowdown pipe to the condensation pool filled with sub-cooled water. The main purpose of the experiments was to study dynamic loads caused by different condensation modes. Particularly, the effect of counterpressure on loads due to pressure oscillations induced by chugging was of interest. Before the experiments the condensation pool was filled with isothermal water so that the blowdown pipe outlet was submerged by 1.03-1.11 m. The initial temperature of the pool water varied from 11 deg. C to 63 deg. C, the steam flow rate from 290 g/s to 1220 g/s and the temperature of incoming steam from 132 deg. C to 182 deg. C. Non-condensables were pushed from the dry well into the gas space of the wet well with a short discharge of steam before the recorded period of the experiments. As a result of this procedure, the system pressure was at an elevated level in the beginning of the actual experiments. An increased counterpressure was used in the last experiment of the series. The diminishing effect of increased system pressure on chugging intensity and on measured loads is evident from the results of the last experiment. The highest pressure pulses both inside the blowdown pipe and in the condensation pool were about half of those measured with a lower system pressure but otherwise with similar test parameters. The experiments on dynamic loading gave expected results. The loads experienced by pool structures depended strongly on the steam mass flow rate, pool water temperature and system pressure. The DYN experiments indicated that chugging and condensation within the blowdown pipe cause significant dynamic loads in case of strongly sub-cooled pool water. The level of pool water temperature is decisive

  17. The heart rate increase at the onset of high-work intensity exercise is accelerated by central blood volume loading.

    Science.gov (United States)

    Miyamoto, Tadayoshi; Oshima, Yoshitake; Ikuta, Komei; Kinoshita, Hiroshi

    2006-01-01

    Using a water immersion (WI) method, the combined effect of central blood volume (CBV) loading and work intensity on the time course of heart rate (HR) at the onset of upright dynamic exercise was investigated. Seven males cranked a cycle ergometer for 12 min using their un-immersed arms at low-, moderate- and high-work intensities, followed by a 12-min rest. For WI, the pre-exercise resting cardiac output increased by 36%, while HR decreased by 22% [from 76.8 (10.4) to 59.6 (9.8) beats/min]. WI also increased the high-frequency (HF, 0.15-0.40 Hz) component of the HR variability, suggesting an increased vagal activity. During the initial 2 min of the exercise period at low-work intensity, HR increased by 34.9 and 25.8% in the WI and control conditions, respectively. These were 117 and 73% at high-work intensity, indicating more accelerated HR with WI than the control. The plasma norepinephrine concentration increased less during high-work intensity exercise during WI, as compared to exercise during control conditions. In conclusion, the HR increase at the onset of high-work intensity exercise is accelerated by CBV loading but not at low intensity, possibly reflecting vago-sympathetic interaction and reduced baroreflex sensitivity.

  18. Microscopic theory of two-dimensional liquid helium

    International Nuclear Information System (INIS)

    Isihara, A.; Um, C.

    1979-01-01

    Starting with real boson particles interacting with a soft potential, it is shown that the excitation spectrum and thermodynamic properties of the system in two dimensions are characterized by the Landau-type quasiparticles. The structure factor, specific heat, and the pair distribution function are explicitly evaluated. The pair distribution function decreases as r -3 at large distances. This decrease corresponds to the existence of a phonon spectrum for small momenta. The normal-fluid density divided by the product of the mass density and absolute temperature cubed is constant near absolute zero, reaches a minimum, and increases at around 0.4 0 K. The roton energy gap is given by the position of the minimum energy and the structure factor at this point. Our value is what we might expect by extrapolating the data by Washburn, Rutledge, and Mochel. It also agrees with the recent result by Rutledge, McMillan, and Mochel. The ground-state energy is also evaluated analytically

  19. Transient analysis of house load operation for LNPP

    International Nuclear Information System (INIS)

    Shi Junying; Zheng Bin

    2000-01-01

    The author analysis the transient of house load operation for Ling'ao Nuclear Power Plant by using the methods of dynamic simulation and closed loops of primary and secondary system. The transient of house load operation from 100% FP is the most severe that can occur on the unit in normal operation because it causes immediately shedding of 95% of turbine load and requires the unit to operate steadily at reduced power. The results show that the transient can be successful both at beginning of core life and manual house load operation. However, more attentions must be paid to automatic house load operation caused by grid fault at toward end of core life because the success of the transient could be threatened by the actuation of the protection of high flux and high flux rate

  20. Transient Performance of Radiator on Engine Rpm Variation with AC Loading

    Directory of Open Access Journals (Sweden)

    Made Ricki Murti

    2012-11-01

    Full Text Available Radiator is one of heat exchanger applications that has a function to remove out of heat must be able to operate properly for allowed engine temperature limit. Vehicles that operate on the street usually driving with varying rpm so that the heat produced by the combustion process is not constant and then this study analyze the performance of radiators as a function of time (transient condition. Tests is done on the condition of operating the engine with five rpm variations, each for one hour with air conditioning load and without air-conditioning load. The data to be collected includ the inlet and outlet temperature of radiator and radiator fluid volume flow. The results obtained is heat exhausted rate as a performance radiator is increasing as with increasing of engine rpm and at load conditions with the AC produces heat exhausted rate is greater than AC without AC load. The heat exhausted rate in an hour of machine operation still shows the system operates at a transient condition due to there still exists a numerical increase in the heat exhausted rate as a function of time.

  1. Heavy-Load Lifting

    DEFF Research Database (Denmark)

    Bloomquist, Kira; Oturai, Peter; Steele, Megan L

    2018-01-01

    of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal....... repetition maximum (RM), two sets of 15-20 repetitions) and heavy-load (85-90% 1RM, three sets of 5-8 repetition) upper-extremity resistance exercise separated by a one-week wash-out period. Swelling was determined by bioimpedance spectroscopy and dual energy x-ray absorptiometry, with breast cancer......-related lymphedema symptoms (heaviness, swelling, pain, tightness) reported using a numeric rating scale (0-10). Order of low- versus heavy-load was randomized. All outcomes were assessed pre-, immediately post-, and 24- and 72-hours post-exercise. Generalized estimating equations were used to evaluate changes over...

  2. Variability of individual genetic load: consequences for the detection of inbreeding depression.

    Science.gov (United States)

    Restoux, Gwendal; Huot de Longchamp, Priscille; Fady, Bruno; Klein, Etienne K

    2012-03-01

    Inbreeding depression is a key factor affecting the persistence of natural populations, particularly when they are fragmented. In species with mixed mating systems, inbreeding depression can be estimated at the population level by regressing the average progeny fitness by the selfing rate of their mothers. We applied this method using simulated populations to investigate how population genetic parameters can affect the detection power of inbreeding depression. We simulated individual selfing rates and genetic loads from which we computed fitness values. The regression method yielded high statistical power, inbreeding depression being detected as significant (5 % level) in 92 % of the simulations. High individual variation in selfing rate and high mean genetic load led to better detection of inbreeding depression while high among-individual variation in genetic load made it more difficult to detect inbreeding depression. For a constant sampling effort, increasing the number of progenies while decreasing the number of individuals per progeny enhanced the detection power of inbreeding depression. We discuss the implication of among-mother variability of genetic load and selfing rate on inbreeding depression studies.

  3. Successful testing of an emergency diesel generator engine at very low load

    International Nuclear Information System (INIS)

    Killinger, A.; Loeper, St.

    2001-01-01

    For more than 30 years, the nuclear power industry has been concerned about the ability of emergency diesel generator sets (EDGs) to operate for extended periods of time at low loads (typically less than 33% of design rating) and still be capable of meeting their design safety requirement. Most diesel engine manufacturers today still caution owners and operators to avoid running their diesel engines for extended periods of time at low loads. At one nuclear power plant, the emergency electrical bus arrangement only required approximately 25% of the EDG's design rating, which necessitated that the plant operators monitor EDG operating hours and periodically increase electrical load. In order to eliminate the plant operations burden of periodically loading the EDGs, the nuclear power plant decided to conduct a low-load test of a ''spare'' diesel engine. A SACM Model UD45V16S5D diesel engine was returned to the factory in Mulhouse, France where the week long testing at rated speed and 3% of design rating was completed. The test demonstrated that the engine was capable of operating for seven days (168 hours) at very low loads, with no loss of performance and no unusual internal wear or degradation. The planning and inspections associated with preparing the diesel engine for the test, the engine monitoring performed during the test, the final test results, and the results and material condition of the engine following the test are described. The successful diesel engine low-load test resulted in the elimination of unnecessary nuclear power plant operation restrictions that were based on old concerns about long-term, low-load operation of diesel engines. The paper describes the significance of this diesel engine test to the nuclear power plant and the entire nuclear power industry. (author)

  4. Load carriage, human performance, and employment standards.

    Science.gov (United States)

    Taylor, Nigel A S; Peoples, Gregory E; Petersen, Stewart R

    2016-06-01

    The focus of this review is on the physiological considerations necessary for developing employment standards within occupations that have a heavy reliance on load carriage. Employees within military, fire fighting, law enforcement, and search and rescue occupations regularly work with heavy loads. For example, soldiers often carry loads >50 kg, whilst structural firefighters wear 20-25 kg of protective clothing and equipment, in addition to carrying external loads. It has long been known that heavy loads modify gait, mobility, metabolic rate, and efficiency, while concurrently elevating the risk of muscle fatigue and injury. In addition, load carriage often occurs within environmentally stressful conditions, with protective ensembles adding to the thermal burden of the workplace. Indeed, physiological strain relates not just to the mass and dimensions of carried objects, but to how those loads are positioned on and around the body. Yet heavy loads must be borne by men and women of varying body size, and with the expectation that operational capability will not be impinged. This presents a recruitment conundrum. How do employers identify capable and injury-resistant individuals while simultaneously avoiding discriminatory selection practices? In this communication, the relevant metabolic, cardiopulmonary, and thermoregulatory consequences of loaded work are reviewed, along with concomitant impediments to physical endurance and mobility. Also emphasised is the importance of including occupation-specific clothing, protective equipment, and loads during work-performance testing. Finally, recommendations are presented for how to address these issues when evaluating readiness for duty.

  5. Effects of regular away travel on training loads, recovery, and injury rates in professional Australian soccer players.

    Science.gov (United States)

    Fowler, Peter; Duffield, Rob; Waterson, Adam; Vaile, Joanna

    2015-07-01

    The current study examined the acute and longitudinal effects of regular away travel on training load (TL), player wellness, and injury surrounding competitive football (soccer) matches. Eighteen male professional football players, representing a team competing in the highest national competition in Australia, volunteered to participate in the study. Training loads, player wellness and injury incidence, rate, severity, and type, together with the activity at the time of injury, were recorded on the day before, the day of, and for 4 d after each of the 27 matches of the 2012-13 season. This included 14 home and 13 away matches, further subdivided based on the midpoint of the season into early (1-13) and late competition (14-27) phases. While TLs were significantly greater on day 3 at home compared with away during the early competition phase (P=.03), no other significant effects of match location were identified (P>.05). Total TL and mean wellness over the 6 d surrounding matches and TL on day 3 were significantly reduced during the late compared with the early competition phase at home and away (P.05), training missed due to injury was 60% and 50% greater during the late than during the early competition phase at home and away, respectively. In conclusion, no significant interactions between match location and competition phase were evident during the late competition phase, which suggests that away travel had negligible cumulative effects on the reduction in player wellness in the latter half of the season.

  6. Dynamic tensile fracture of mortar at ultra-high strain-rates

    International Nuclear Information System (INIS)

    Erzar, B.; Buzaud, E.; Chanal, P.-Y.

    2013-01-01

    During the lifetime of a structure, concrete and mortar may be exposed to highly dynamic loadings, such as impact or explosion. The dynamic fracture at high loading rates needs to be well understood to allow an accurate modeling of this kind of event. In this work, a pulsed-power generator has been employed to conduct spalling tests on mortar samples at strain-rates ranging from 2 × 10 4 to 4 × 10 4  s −1 . The ramp loading allowed identifying the strain-rate anytime during the test. A power law has been proposed to fit properly the rate-sensitivity of tensile strength of this cementitious material over a wide range of strain-rate. Moreover, a specimen has been recovered damaged but unbroken. Micro-computed tomography has been employed to study the characteristics of the damage pattern provoked by the dynamic tensile loading

  7. Monitoring training load to understand fatigue in athletes.

    Science.gov (United States)

    Halson, Shona L

    2014-11-01

    Many athletes, coaches, and support staff are taking an increasingly scientific approach to both designing and monitoring training programs. Appropriate load monitoring can aid in determining whether an athlete is adapting to a training program and in minimizing the risk of developing non-functional overreaching, illness, and/or injury. In order to gain an understanding of the training load and its effect on the athlete, a number of potential markers are available for use. However, very few of these markers have strong scientific evidence supporting their use, and there is yet to be a single, definitive marker described in the literature. Research has investigated a number of external load quantifying and monitoring tools, such as power output measuring devices, time-motion analysis, as well as internal load unit measures, including perception of effort, heart rate, blood lactate, and training impulse. Dissociation between external and internal load units may reveal the state of fatigue of an athlete. Other monitoring tools used by high-performance programs include heart rate recovery, neuromuscular function, biochemical/hormonal/immunological assessments, questionnaires and diaries, psychomotor speed, and sleep quality and quantity. The monitoring approach taken with athletes may depend on whether the athlete is engaging in individual or team sport activity; however, the importance of individualization of load monitoring cannot be over emphasized. Detecting meaningful changes with scientific and statistical approaches can provide confidence and certainty when implementing change. Appropriate monitoring of training load can provide important information to athletes and coaches; however, monitoring systems should be intuitive, provide efficient data analysis and interpretation, and enable efficient reporting of simple, yet scientifically valid, feedback.

  8. Extremely fast increase in the organic loading rate during the co-digestion of rapeseed oil and sewage sludge in a CSTR--characterization of granules formed due to CaO addition to maintain process stability.

    Science.gov (United States)

    Kasina, M; Kleyböcker, A; Michalik, M; Würdemann, H

    2015-01-01

    In a co-digestion system running with rapeseed oil and sewage sludge, an extremely fast increase in the organic loading rate was studied to develop a procedure to allow for flexible and demand-driven energy production. The over-acidification of the digestate was successfully prevented by calcium oxide dosage, which resulted in granule formation. Mineralogical analyses revealed that the granules were composed of insoluble salts of long chain fatty acids and calcium and had a porous structure. Long chain fatty acids and calcium formed the outer cover of granules and offered interfaces on the inside thereby enhancing the growth of biofilms. With granule size and age, the pore size increased and indicated degradation of granular interfaces. A stable biogas production up to the organic loading rate of 10.4 kg volatile solids m(-3) d(-1) was achieved although the hydrogen concentration was not favorable for propionic acid degradation. However, at higher organic loading rates, unbalanced granule formation and degradation were observed. Obviously, the adaption time for biofilm growth was too short to maintain the balance, thereby resulting in a low methane yield.

  9. Dispersion of Bed Load Particles

    OpenAIRE

    SAWAI, Kenji

    1987-01-01

    The motion of bed load particles is so irregular that they disperse remarkably with time.In this study, some flume tests using painted tracer particles were carried out, in which thedispersive property of tracers changed variously with sediment feed rate.In analysing this process, a stochastic simulation model is proposed where it is discussedabout the degree of exposure of individual particle near the bed surface and about the variationof its pick up rate. The exponential distribution of ste...

  10. Node Load Balance Multi-flow Opportunistic Routing in Wireless Mesh Networks

    Directory of Open Access Journals (Sweden)

    Wang Tao

    2014-04-01

    Full Text Available Opportunistic routing (OR has been proposed to improve the performance of wireless networks by exploiting the multi-user diversity and broadcast nature of the wireless medium. It involves multiple candidate forwarders to relay packets every hop. The existing OR doesn’t take account of the traffic load and load balance, therefore some nodes may be overloaded while the others may not, leading to network performance decline. In this paper, we focus on opportunities routing selection with node load balance which is described as a convex optimization problem. To solve the problem, by combining primal-dual and sub-gradient methods, a fully distributed Node load balance Multi-flow Opportunistic Routing algorithm (NMOR is proposed. With node load balance constraint, NMOR allocates the flow rate iteratively and the rate allocation decides the candidate forwarder selection of opportunities routing. The simulation results show that NMOR algorithm improves 100 %, 62 % of the aggregative throughput than ETX and EAX, respectively.

  11. Estimating the cost of mental loading in a bimodal divided-attention task: Combining reaction time, heart-rate variability and signal-detection theory

    Science.gov (United States)

    Casper, Patricia A.; Kantowitz, Barry H.

    1988-01-01

    Multiple approaches are necessary for understanding and measuring workload. In particular, physiological systems identifiable by employing cardiac measures are related to cognitive systems. One issue of debate in measuring cardiac output is the grain of analysis used in recording and summarizing data. Various experiments are reviewed, the majority of which were directed at supporting or contradicting Lacey's intake-rejection hypothesis. Two of the experiments observed heart rate in operational environments and found virtually no changes associated with mental load. The major problems facing researchers using heart rate variability, or sinus arrhthmia, as a dependent measure have been associated with valid and sensitive scoring and preventing contamination of observed results by influences unrelated to cognition. Spectral analysis of heart rate variability offers two useful procedures: analysis from the time domain and analysis from the frequency domain. Most recently, data have been collected in a divided attention experiment, the performance measures and cardiac measures of which are detailed.

  12. Load alleviation of wind turbines by yaw misalignment

    DEFF Research Database (Denmark)

    Kragh, Knud Abildgaard; Hansen, Morten Hartvig

    2014-01-01

    Vertical wind shear is one of the dominating causes of load variations on the blades of a horizontal axis wind turbine. To alleviate the varying loads, wind turbine control systems have been augmented with sensors and actuators for individual pitch control. However, the loads caused by a vertical...... wind shear can also be affected through yaw misalignment. Recent studies of yaw control have been focused on improving the yaw alignment to increase the power capture at below rated wind speeds. In this study, the potential of alleviating blade load variations induced by the wind shear through yaw...... misalignment is assessed. The study is performed through simulations of a reference turbine. The study shows that optimal yaw misalignment angles for minimizing the blade load variations can be identified for both deterministic and turbulent inflows. It is shown that the optimal yaw misalignment angles can...

  13. A model for damage load and its implications for the evolution of bacterial aging.

    Directory of Open Access Journals (Sweden)

    Lin Chao

    2010-08-01

    Full Text Available Deleterious mutations appearing in a population increase in frequency until stopped by natural selection. The ensuing equilibrium creates a stable frequency of deleterious mutations or the mutational load. Here I develop the comparable concept of a damage load, which is caused by harmful non-heritable changes to the phenotype. A damage load also ensues when the increase of damage is opposed by selection. The presence of a damage load favors the evolution of asymmetrical transmission of damage by a mother to her daughters. The asymmetry is beneficial because it increases fitness variance, but it also leads to aging or senescence. A mathematical model based on microbes reveals that a cell lineage dividing symmetrically is immortal if lifetime damage rates do not exceed a threshold. The evolution of asymmetry allows the lineage to persist above the threshold, but the lineage becomes mortal. In microbes with low genomic mutation rates, it is likely that the damage load is much greater than the mutational load. In metazoans with higher genomic mutation rates, the damage and the mutational load could be of the same magnitude. A fit of the model to experimental data shows that Escherichia coli cells experience a damage rate that is below the threshold and are immortal under the conditions examined. The model estimates the asymmetry level of E. coli to be low but sufficient for persisting at higher damage rates. The model also predicts that increasing asymmetry results in diminishing fitness returns, which may explain why the bacterium has not evolved higher asymmetry.

  14. Handling load with less stress

    NARCIS (Netherlands)

    Bansal, N.; Gamarnik, D.

    2006-01-01

    We study how the average performance of a system degrades as the load nears its peak capacity. We restrict our attention to the performance measures of average sojourn time and the large deviation rates of buffer overflow probabilities. We first show that for certain queueing systems, the average

  15. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. Practising what we preach: using cognitive load theory for workshop design and evaluation.

    Science.gov (United States)

    Naismith, Laura M; Haji, Faizal A; Sibbald, Matthew; Cheung, Jeffrey J H; Tavares, Walter; Cavalcanti, Rodrigo B

    2015-12-01

    Theory-based instructional design is a top priority in medical education. The goal of this Show and Tell article is to present our theory-driven approach to the design of instruction for clinical educators. We adopted cognitive load theory as a framework to design and evaluate a series of professional development workshops that were delivered at local, national and international academic conferences in 2014. We used two rating scales to measure participants' cognitive load. Participants also provided narrative comments as to how the workshops could be improved. Cognitive load ratings from 59 participants suggested that the workshop design optimized learning by managing complexity for different levels of learners (intrinsic load), stimulating cognitive processing for long-term memory storage (germane load), and minimizing irrelevant distracters (extraneous load). Narrative comments could also be classified as representing intrinsic, extraneous, or germane load, which provided specific directions for ongoing quality improvement. These results demonstrate that a cognitive load theory approach to workshop design and evaluation is feasible and useful in the context of medical education.

  17. Mitigating the Long term Operating Extreme Load through Active Control

    DEFF Research Database (Denmark)

    Koukoura, Christina; Natarajan, Anand

    2014-01-01

    blade azimuth location are shown to affect the extreme blade load magnitude during operation in normal turbulence wind input. The simultaneously controlled operation of generator torque variation and pitch variation at low blade pitch angles is detected to be responsible for very high loads acting...... on the blades. Through gain scheduling of the controller (modifications of the proportional Kp and the integral Ki gains) the extreme loads are mitigated, ensuring minimum instantaneous variations in the power production for operation above rated wind speed. The response of the blade load is examined...

  18. Local wall power loading variations in thermonuclear fusion devices

    International Nuclear Information System (INIS)

    Carroll, M.C.; Miley, G.H.

    1989-01-01

    A 2 1/2-dimensional geometric model is presented that allows calculation of power loadings at various points on the first wall of a thermonuclear fusion device. Given average wall power loadings for brems-strahlung, cyclotron radiation charged particles, and neutrons, which are determined from various plasma-physics computation models, local wall heat loads are calculated by partitioning the plasma volume and surface into cells and superimposing the heating effects of the individual cells on selected first-wall differential areas. Heat loads from the entire plasma are thus determined as a function of position on the first-wall surface. Significant differences in local power loadings were found for most fusion designs, and it was therefore concluded that the effect of local power loading variations must be taken into account when calculating temperatures and heat transfer rates in fusion device first walls

  19. Load research manual. Volume 1. Load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  20. Enzyme loading dependence of cellulose hydrolysis of sugarcane bagasse

    Directory of Open Access Journals (Sweden)

    Carlos Martín

    2012-01-01

    Full Text Available The enzymatic hydrolysis of steam-pretreated sugarcane bagasse, either delignified or non-delignified, was studied as a function of enzyme loading. Hydrolysis experiments were carried out using five enzyme loadings (2.5 to 20 FPU/g cellulose and the concentration of solids was 2% for both materials. Alkaline delignification improved cellulose hydrolysis by increasing surface area. For both materials, glucose concentrations increased with enzyme loading. On the other hand, enzyme loadings higher than 15 FPU/g did not result in any increase in the initial rate, since the excess of enzyme adsorbed onto the substrate restricted the diffusion process through the structure.

  1. Temporal pattern of emotions and cognitive load during simulation training and debriefing.

    Science.gov (United States)

    Fraser, Kristin; McLaughlin, Kevin

    2018-04-24

    In the simulated clinical environment, there is a perceived benefit to the emotional activation experienced by learners; however, potential harm of excessive and/or negative emotions has also been hypothesized. An improved understanding of the emotional experiences of learners during each phase of the simulation session will inform instructional design. In this observational study, we asked 174 first-year medical students about their emotional state upon arrival to the simulation lab (t1). They were then trained on a standard simulation scenario, after which they rated their emotional state and perceived cognitive load (t2). After debriefing, we then asked them to again rate their emotions and cognitive load (t3). Students reported that their experience of tranquility (a positive and low-arousal state) dropped from pre-scenario (t1) to post-scenario (t2), and returned to baseline levels after debriefing (t3), from 0.69 (0.87) to 0.14 (0.78) to 0.62 (0.78). Post scenario cognitive load was rated to be moderately high at 6.62 (1.12) and scores increased after debriefing to 6.90 (1.05) d = 0.26, p Cognitive load was associated with the simultaneous measures of emotions at both t2 and t3. Participant emotions are significantly altered through the experience of medical simulation and emotions are associated with subjective ratings of cognitive load.

  2. Load power device, system and method of load control and management employing load identification

    Science.gov (United States)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  3. ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings

    NARCIS (Netherlands)

    Drachsler, Hendrik; Pecceu, Dries; Arts, Tanja; Hutten, Edwin; Rutledge, Lloyd; Van Rosmalen, Peter; Hummel, Hans; Koper, Rob

    2009-01-01

    Drachsler, H., Peccau, D., Arts, T., Hutten, E., Rutledge, L., Van Rosmalen, P., Hummel, H. G. K., & Koper, R. (2009). ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings. In F. Wild, M. Kalz, M. Palmér & D. Müller (Eds.),

  4. A numerical basis for strain-gradient plasticity theory: Rate-independent and rate-dependent formulations

    DEFF Research Database (Denmark)

    Nielsen, Kim Lau; Niordson, Christian Frithiof

    2014-01-01

    of a single plastic zone is analyzed to illustrate the agreement with earlier published results, whereafter examples of (ii) multiple plastic zone interaction, and (iii) elastic–plastic loading/unloading are presented. Here, the simple shear problem of an infinite slab constrained between rigid plates......A numerical model formulation of the higher order flow theory (rate-independent) by Fleck and Willis [2009. A mathematical basis for strain-gradient plasticity theory – part II: tensorial plastic multiplier. Journal of the Mechanics and Physics of Solids 57, 1045-1057.], that allows for elastic–plastic...... loading/unloading and the interaction of multiple plastic zones, is proposed. The predicted model response is compared to the corresponding rate-dependent version of visco-plastic origin, and coinciding results are obtained in the limit of small strain-rate sensitivity. First, (i) the evolution...

  5. Fatigue Crack Propagation Under Variable Amplitude Loading Analyses Based on Plastic Energy Approach

    Directory of Open Access Journals (Sweden)

    Sofiane Maachou

    2014-04-01

    Full Text Available Plasticity effects at the crack tip had been recognized as “motor” of crack propagation, the growth of cracks is related to the existence of a crack tip plastic zone, whose formation and intensification is accompanied by energy dissipation. In the actual state of knowledge fatigue crack propagation is modeled using crack closure concept. The fatigue crack growth behavior under constant amplitude and variable amplitude loading of the aluminum alloy 2024 T351 are analyzed using in terms energy parameters. In the case of VAL (variable amplitude loading tests, the evolution of the hysteretic energy dissipated per block is shown similar with that observed under constant amplitude loading. A linear relationship between the crack growth rate and the hysteretic energy dissipated per block is obtained at high growth rates. For lower growth rates values, the relationship between crack growth rate and hysteretic energy dissipated per block can represented by a power law. In this paper, an analysis of fatigue crack propagation under variable amplitude loading based on energetic approach is proposed.

  6. Muscle force depends on the amount of transversal muscle loading.

    Science.gov (United States)

    Siebert, Tobias; Till, Olaf; Stutzig, Norman; Günther, Michael; Blickhan, Reinhard

    2014-06-03

    Skeletal muscles are embedded in an environment of other muscles, connective tissue, and bones, which may transfer transversal forces to the muscle tissue, thereby compressing it. In a recent study we demonstrated that transversal loading of a muscle with 1.3Ncm(-2) reduces maximum isometric force (Fim) and rate of force development by approximately 5% and 25%, respectively. The aim of the present study was to examine the influence of increasing transversal muscle loading on contraction dynamics. Therefore, we performed isometric experiments on rat M. gastrocnemius medialis (n=9) without and with five different transversal loads corresponding to increasing pressures of 1.3Ncm(-2) to 5.3Ncm(-2) at the contact area between muscle and load. Muscle loading was induced by a custom-made plunger which was able to move in transversal direction. Increasing transversal muscle loading resulted in an almost linear decrease in muscle force from 4.8±1.8% to 12.8±2% Fim. Compared to an unloaded isometric contraction, rate of force development decreased from 20.2±4.0% at 1.3Ncm(-2) muscle loading to 34.6±5.7% at 5.3Ncm(-2). Experimental observation of the impact of transversal muscle loading on contraction dynamics may help to better understand muscle tissue properties. Moreover, applying transversal loads to muscles opens a window to analyze three-dimensional muscle force generation. Data presented in this study may be important to develop and validate muscle models which enable simulation of muscle contractions under compression and enlighten the mechanisms behind. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Ammonia threshold for inhibition of anaerobic digestion of thin stillage and the importance of organic loading rate.

    Science.gov (United States)

    Moestedt, Jan; Müller, Bettina; Westerholm, Maria; Schnürer, Anna

    2016-03-01

    Biogas production from nitrogen-rich feedstock results in release of ammonia (NH3), causing inhibition of the microbial process. The reported threshold ammonia value for stable biogas production varies greatly between studies, probably because of differences in operating conditions. Moreover, it is often difficult to separate the effect of ammonia inhibition from that of organic loading rate (OLR), as these two factors are often interrelated. This study attempted to distinguish the effects of ammonia and OLR by analysis of two laboratory-scale biogas reactors operating with thin stillage and subjected to an increase in free ammonia (from 0.30 to 1.1 g L(-1)) either by addition of an external nitrogen source (urea) or by increasing the OLR (3.2-6.0 g volatile solids L(-1) d(-1)). The results showed that ammonia concentration was detrimental for process performance, with the threshold for stability in both processes identified as being about 1 g NH3-N L(-1), irrespective of OLR. Analysis of the methanogenic community showed limited differences between the two reactors on order level and a clear increase in the abundance of Methanomicrobiales, particularly Methanoculleus sp., in response to increasing ammonia concentration. Further comprehensive molecular analysis revealed that diverse Methanoculleus species dominated in the reactors at a given ammonia level at different OLR. The acetogenic community was clearly affected by both ammonia concentration and OLR, suggesting that the volatile fatty acid load in relation to the higher OLR was important for the dynamics of this community. © 2015 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  8. The effect of organic loading rate and retention time on hydrogen production from a methanogenic CSTR.

    Science.gov (United States)

    Pakarinen, O; Kaparaju, P; Rintala, J

    2011-10-01

    The possibility of shifting a methanogenic process for hydrogen production by changing the process parameters viz., organic loading rate (OLR) and hydraulic retention time (HRT) was evaluated. At first, two parallel semi-continuously fed continuously stirred tank reactors (CSTR) were operated as methanogenic reactors (M1 and M2) for 78 days. Results showed that a methane yield of 198-218 L/kg volatile solids fed (VS(fed)) was obtained when fed with grass silage at an OLR of 2 kgVS/m³/d and HRT of 30 days. After 78 days of operation, hydrogen production was induced in M2 by increasing the OLR from 2 to 10 kgVS/m³/d and shortening the HRT from 30 to 6 days. The highest H₂ yield of 42 L/kgVS(fed) was obtained with a maximum H₂ content of 24%. The present results thus demonstrate that methanogenic process can be shifted towards hydrogen production by increasing the OLR and decreasing HRT. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Volatile fatty acids production from food waste: effects of pH, temperature, and organic loading rate.

    Science.gov (United States)

    Jiang, Jianguo; Zhang, Yujing; Li, Kaimin; Wang, Quan; Gong, Changxiu; Li, Menglu

    2013-09-01

    The effects of pH, temperature, and organic loading rate (OLR) on the acidogenesis of food waste have been determined. The present study investigated their effects on soluble chemical oxygen demand (SCOD), volatile fatty acids (VFAs), volatile solids (VS), and ammonia nitrogen (NH4(+)-N). Both the concentration and yield of VFAs were highest at pH 6.0, acetate and butyrate accounted for 77% of total VFAs. VFAs concentration and the VFA/SCOD ratio were highest, and VS levels were lowest, at 45 °C, but the differences compared to the values at 35 °C were slight. The concentrations of VFAs, SCOD, and NH4(+)-N increased as OLR increased, whereas the yield of VFAs decreased from 0.504 at 5 g/Ld to 0.306 at 16 g/Ld. Acetate and butyrate accounted for 60% of total VFAs. The percentage of acetate and valerate increased as OLR increased, whereas a high OLR produced a lower percentage of propionate and butyrate. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Concrete structures under impact loading: general aspects

    Directory of Open Access Journals (Sweden)

    Cornelia Baeră

    2016-09-01

    Full Text Available Dynamic loading conditions distress the structural integrity of a structure differently than the static ones. Such actions transfer high rate strains and instant energy waves to the structure, inducing the possibility of imminent collapse and casualties as a direct consequence. In the latest years, considering the dramatic increase of terrorist threats and global warming, the structural safety criteria imply more than ever the need to withstand this kind of loading (e.g., missiles and blast, projectiles, strong winds, tornados and earthquakes in addition to the static ones. The aim of this paper is to provide a general overview with regard to impact loading in terms of defining the phenomenon from physical and mechanical perspective, its complex local or global effect on the targeted structure, relevant material characteristics, main research approaches, namely theoretical studies and experimental procedures developed for improving the predictability of the dynamic loads and their effects. New directions in developing superior cementitious composites, with better characteristics in terms of dynamic loading performance are also emphasized.

  11. Research on the Transient Characteristics of Microgrid with Pulsed Load

    Directory of Open Access Journals (Sweden)

    Jianke Li

    2015-01-01

    Full Text Available Unlike traditional load, pulsed load typically features small average power and large peak power. In this paper, the mathematic models of microgrid consisting of synchronous generator and pulsed load are established. Average Magnitude Difference Compensate Function (AMDCF is proposed to calculate the frequency of synchronous generator, and, based on AMDCF, relative deviation rate (RDR which characterizes the impact of pulsed load on the AC side of grid is firstly defined and this paper describes calculation process in detail. Insulated Gate Bipolar Transistor (IGBT is used as DC switch to control the on/off state of resistive load for simulating pulsed load, the period and duty-cycle of the pulsed load are simulated by setting the gate signal of IGBT, and the peak power of the pulsed load is simulated by setting the resistance. The system dynamic characteristics under pulsed load are analyzed in detail, and the influence of duty-cycle, period, peak power, and filter capacitance of the pulsed load on system dynamic indicators is studied and validated experimentally.

  12. Compression-rate-dependent nonlinear mechanics of normal and impaired porcine knee joints.

    Science.gov (United States)

    Rodriguez, Marcel Leonardo; Li, LePing

    2017-11-14

    The knee joint performs mechanical functions with various loading and unloading processes. Past studies have focused on the kinematics and elastic response of the joint with less understanding of the rate-dependent load response associated with viscoelastic and poromechanical behaviors. Forty-five fresh porcine knee joints were used in the present study to determine the loading-rate-dependent force-compression relationship, creep and relaxation of normal, dehydrated and meniscectomized joints. The mechanical tests of all normal intact joints showed similar strong compression-rate-dependent behavior: for a given compression-magnitude up to 1.2 mm, the reaction force varied 6 times over compression rates. While the static response was essentially linear, the nonlinear behavior was boosted with the increased compression rate to approach the asymptote or limit at approximately 2 mm/s. On the other hand, the joint stiffness varied approximately 3 times over different joints, when accounting for the maturity and breed of the animals. Both a loss of joint hydration and a total meniscectomy greatly compromised the load support in the joint, resulting in a reduction of load support as much as 60% from the corresponding intact joint. However, the former only weakened the transient load support, but the latter also greatly weakened the equilibrium load support. A total meniscectomy did not diminish the compression-rate-dependence of the joint though. These findings are consistent with the fluid-pressurization loading mechanism, which may have a significant implication in the joint mechanical function and cartilage mechanobiology.

  13. Deformation twinning: Influence of strain rate

    Energy Technology Data Exchange (ETDEWEB)

    Gray, G.T. III

    1993-11-01

    Twins in most crystal structures, including advanced materials such as intermetallics, form more readily as the temperature of deformation is decreased or the rate of deformation is increased. Both parameters lead to the suppression of thermally-activated dislocation processes which can result in stresses high enough to nucleate and grow deformation twins. Under high-strain rate or shock-loading/impact conditions deformation twinning is observed to be promoted even in high stacking fault energy FCC metals and alloys, composites, and ordered intermetallics which normally do not readily deform via twinning. Under such conditions and in particular under the extreme loading rates typical of shock wave deformation the competition between slip and deformation twinning can be examined in detail. In this paper, examples of deformation twinning in the intermetallics TiAl, Ti-48Al-lV and Ni{sub 3}A as well in the cermet Al-B{sub 4}C as a function of strain rate will be presented. Discussion includes: (1) the microstructural and experimental variables influencing twin formation in these systems and twinning topics related to high-strain-rate loading, (2) the high velocity of twin formation, and (3) the influence of deformation twinning on the constitutive response of advanced materials.

  14. Storm loads of culturable and molecular fecal indicators in an inland urban stream.

    Science.gov (United States)

    Liao, Hehuan; Krometis, Leigh-Anne H; Cully Hession, W; Benitez, Romina; Sawyer, Richard; Schaberg, Erin; von Wagoner, Emily; Badgley, Brian D

    2015-10-15

    Elevated concentrations of fecal indicator bacteria in receiving waters during wet-weather flows are a considerable public health concern that is likely to be exacerbated by future climate change and urbanization. Knowledge of factors driving the fate and transport of fecal indicator bacteria in stormwater is limited, and even less is known about molecular fecal indicators, which may eventually supplant traditional culturable indicators. In this study, concentrations and loading rates of both culturable and molecular fecal indicators were quantified throughout six storm events in an instrumented inland urban stream. While both concentrations and loading rates of each fecal indicator increased rapidly during the rising limb of the storm hydrographs, it is the loading rates rather than instantaneous concentrations that provide a better estimate of transport through the stream during the entire storm. Concentrations of general fecal indicators (both culturable and molecular) correlated most highly with each other during storm events but not with the human-associated HF183 Bacteroides marker. Event loads of general fecal indicators most strongly correlated with total runoff volume, maximum discharge, and maximum turbidity, while event loads of HF183 most strongly correlated with the time to peak flow in a hydrograph. These observations suggest that collection of multiple samples during a storm event is critical for accurate predictions of fecal indicator loading rates and total loads during wet-weather flows, which are required for effective watershed management. In addition, existing predictive models based on general fecal indicators may not be sufficient to predict source-specific genetic markers of fecal contamination. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Satellite observation analysis of aerosols loading effect over Monrovia-Liberia

    International Nuclear Information System (INIS)

    Emetere, M E; Esisio, F; Oladapo, F

    2017-01-01

    The effect of aerosols loading most often results in aerosols retention in the atmosphere. Aside the health hazards of aerosol retention, its effect on climate change are visible. In this research, it was proposed that the effect of aerosol retention also affects rain pattern. The Tropical Rainfall Measuring Mission (TRMM) layer 3 observations and the multi-imaging spectro-reflectometer (MISR) was used for the study. The aerosols loading over were investigated using sixteen years satellite observation in Monrovia-Liberia. Its effect on the rain rate over the region was documented. The results show that aerosol loading over the region is high and may have effect on farming in the nearest future. It was affirmed that the scanty AOD data was as a result of the rain rate that is higher within May and October. (paper)

  16. Satellite observation analysis of aerosols loading effect over Monrovia-Liberia

    Science.gov (United States)

    Emetere, M. E.; Esisio, F.; Oladapo, F.

    2017-05-01

    The effect of aerosols loading most often results in aerosols retention in the atmosphere. Aside the health hazards of aerosol retention, its effect on climate change are visible. In this research, it was proposed that the effect of aerosol retention also affects rain pattern. The Tropical Rainfall Measuring Mission (TRMM) layer 3 observations and the multi-imaging spectro-reflectometer (MISR) was used for the study. The aerosols loading over were investigated using sixteen years satellite observation in Monrovia-Liberia. Its effect on the rain rate over the region was documented. The results show that aerosol loading over the region is high and may have effect on farming in the nearest future. It was affirmed that the scanty AOD data was as a result of the rain rate that is higher within May and October.

  17. Macrophyte Community Response to Nitrogen Loading and ...

    Science.gov (United States)

    Empirical determination of nutrient loading thresholds that negatively impact seagrass communities have been elusive due to the multitude of factors involved. Using a mesocosm system that simulated Pacific Northwest estuaries, we evaluated macrophyte metrics across gradients of NO3 loading (0, 1.5, 3 and 6x ambient) and temperature (10 and 20 °C). Macroalgal growth, biomass, and C:N responded positively to increased NO3 load and floating algal mats developed at 20 ºC. Zostera japonica metrics, including C:N, responded more to temperature than to NO3 loading. Z. marina biomass exhibited a negative temperature effect and in some cases a negative NO3 effect, while growth rate increased with temperature. Shoot survival decreased at 20 ºC but was not influenced by NO3 loading. Wasting disease index exhibited a significant temperature by NO3 interaction consistent with increased disease susceptibility. Community shifts observed were consistent with the nutrient loading hypothesis at 20 ºC, but there was no evidence of other eutrophication symptoms due to the short residence time. The Nutrient Pollution Index tracked the NO3 gradient at 10 ºC but exhibited no response at 20 ºC. We suggest that systems characterized by cool temperatures, high NO3 loads, and short residence time may be resilient to many symptoms of eutrophication. Estuarine systems characterized by cool temperatures, high nutrient loads and rapid flushing may be resilient to some symptoms

  18. The Influence of Loading Rate and Variable Temperatures on Microbial Communities in Anaerobic Digesters

    Directory of Open Access Journals (Sweden)

    Richard J. Ciotola

    2014-02-01

    Full Text Available The relationship between seasonal temperatures, organic loading rate (OLR and the structure of archaeal communities in anaerobic digesters was investigated. Previous studies have often assessed archaeal community structure at fixed temperatures and constant OLRs, or at variable temperatures not characteristic of temperate climates. The goal of this study was to determine the maximum OLR that would maintain a balanced microbial ecosystem during operation in a variable temperature range expected in a temperate climate (27–10 °C. Four-liter laboratory digesters were operated in a semi-continuous mode using dairy cow manure as the feedstock. At OLRs of 1.8 and 0.8 kg VS/m3·day the digesters soured (pH < 6.5 as a result of a decrease in temperature. The structure of the archaeal community in the sour digesters became increasingly similar to the manure feedstock with gains in the relative abundance of hydrogenotrophic methanogens. At an OLR of 0.3 kg VS/m3·day the digesters did not sour, but the archaeal community was primarily hydrogenotrophic methanogens. Recommendations for operating an ambient temperature digester year round in a temperate climate are to reduce the OLR to at least 0.3 kg VS/m3·day in colder temperatures to prevent a shift to the microbial community associated with the sour digesters.

  19. Skilled Memory.

    Science.gov (United States)

    1980-11-06

    Woodworth, R. S. Experimental Psychology. New York: Henry Holt and Co., 1938. Yates, F. A. The art of memory. London: Rutledge and Kegan Paul, 1966. 50...Group 1 Psychologist (TAEG) ON! Branch Office Dept. of the Navy 1030 East Green Street Orlando, FL 32813 Pasadena, CA 91101 1 Dr. Richard Sorensen I

  20. Assessing the long term impact of phosphorus fertilization on phosphorus loadings using AnnAGNPS.

    Science.gov (United States)

    Yuan, Yongping; Bingner, Ronald L; Locke, Martin A; Stafford, Jim; Theurer, Fred D

    2011-06-01

    High phosphorus (P) loss from agricultural fields has been an environmental concern because of potential water quality problems in streams and lakes. To better understand the process of P loss and evaluate the effects of different phosphorus fertilization rates on phosphorus losses, the USDA Annualized AGricultural Non-Point Source (AnnAGNPS) pollutant loading model was applied to the Ohio Upper Auglaize watershed, located in the southern portion of the Maumee River Basin. In this study, the AnnAGNPS model was calibrated using USGS monitored data; and then the effects of different phosphorus fertilization rates on phosphorus loadings were assessed. It was found that P loadings increase as fertilization rate increases, and long term higher P application would lead to much higher P loadings to the watershed outlet. The P loadings to the watershed outlet have a dramatic change after some time with higher P application rate. This dramatic change of P loading to the watershed outlet indicates that a "critical point" may exist in the soil at which soil P loss to water changes dramatically. Simulations with different initial soil P contents showed that the higher the initial soil P content is, the less time it takes to reach the "critical point" where P loadings to the watershed outlet increases dramatically. More research needs to be done to understand the processes involved in the transfer of P between the various stable, active and labile states in the soil to ensure that the model simulations are accurate. This finding may be useful in setting up future P application and management guidelines.

  1. Analysis of interfacial crack propagation under asymmetric loading in anisotropic materials

    International Nuclear Information System (INIS)

    Pryce, L; Mishuris, G; Morini, L

    2013-01-01

    This paper considers a steady-state crack propagating along an interface between dissimilar orthotropic materials under an asymmetric load. Although most of the known results so far deal with symmetric loading, it has been shown recently that a significant asymmetry in the applied loading may lead to a pronounced effect in terms of the values of the SIFs. The aim of the paper is to extend these results from the static case to a moving crack. In particular, we show the significance of the asymmetry of the loading for computing the energy release rate

  2. Engineering to Control Noise, Loading, and Optimal Operating Points

    International Nuclear Information System (INIS)

    Mitchell R. Swartz

    2000-01-01

    Successful engineering of low-energy nuclear systems requires control of noise, loading, and optimum operating point (OOP) manifolds. The latter result from the biphasic system response of low-energy nuclear reaction (LENR)/cold fusion systems, and their ash production rate, to input electrical power. Knowledge of the optimal operating point manifold can improve the reproducibility and efficacy of these systems in several ways. Improved control of noise, loading, and peak production rates is available through the study, and use, of OOP manifolds. Engineering of systems toward the OOP-manifold drive-point peak may, with inclusion of geometric factors, permit more accurate uniform determinations of the calibrated activity of these materials/systems

  3. Cognitive load theory: Practical implications and an important challenge

    Directory of Open Access Journals (Sweden)

    Jimmie Leppink, Ph.D.

    2017-10-01

    Full Text Available The field of medical education has adopted a wide variety of theories from other fields. A fairly recent example is cognitive load theory, which originated in educational psychology. Several empirical studies inspired by cognitive load theory and reviews of practical implications of cognitive load theory have contributed to guidelines for the design of medical education. Simultaneously, several research groups have developed instruments for the measurement of cognitive load in a medical education context. These developments notwithstanding, obtaining evidence for different types of cognitive load remains an important challenge. Therefore, the aim of this article is twofold: to provide medical educators with three key guidelines for the design of instruction and assessment and to discuss several fundamental issues in the remaining challenges presented by different types of cognitive load. The guidelines revolve around minimizing cognitive activity that does not contribute to learning, working with specific learning goals in mind, and appreciating the multifaceted relation between learning and assessment. Key issues around the types of cognitive load include the context in which learning occurs, the continued use of single-item mental effort ratings, and the timing of cognitive load and learning outcome measurements.

  4. Porters of the eastern hills of Nepal: Body size and load weight.

    Science.gov (United States)

    Malville, Nancy J.

    1999-01-01

    This study documents the activities of 635 porters transporting goods along three traditional trade routes of eastern Nepal. Nearly 95% of the porters were male. They ranged in age from 10-65 years, and most of them had begun to perform long-distance portage at 12-15 years of age. Mean body mass and height of adult males in the combined sample (n = 438) was 49.7 +/- 5.0 kg and 155.5 +/- 6.5 cm, respectively. Adult males age 20-49 years carried loads of 73 +/- 15 kg, equivalent to 146% +/- 30% of body mass. Body size of adult males was not a strong predictor of load weight. The correlation between body mass and load was r = 0.24 (P porters to carry such large loads in spite of their small body size is the ability to pace themselves by making frequent rest stops. Heart rate monitoring of 26 adult male commercial porters demonstrated how porters regulate heart rate and energy expenditure by resting the load every two to three minutes on the T-headed walking stick (tokma) and by setting the load periodically on load-resting platforms (chautaras) for longer recovery periods. Am. J. Hum. Biol. 11:1-11, 1999. Copyright 1999 Wiley-Liss, Inc.

  5. Distribution load forecast with interactive correction of horizon loads

    International Nuclear Information System (INIS)

    Glamochanin, V.; Andonov, D.; Gagovski, I.

    1994-01-01

    This paper presents the interactive distribution load forecast application that performs the distribution load forecast with interactive correction of horizon loads. It consists of two major parts implemented in Fortran and Visual Basic. The Fortran part is used for the forecasts computations. It consists of two methods: Load Transfer Coupling Curve Fitting (LTCCF) and load Forecast Using Curve Shape Clustering (FUCSC). LTCCF is used to 'correct' the contaminated data because of load transfer among neighboring distribution areas. FUCSC uses curve shape clustering to forecast the distribution loads of small areas. The forecast for each small area is achieved by using the shape of corresponding cluster curve. The comparison of forecasted loads of the area with historical data will be used as a tool for the correction of the estimated horizon load. The Visual Basic part is used to provide flexible interactive user-friendly environment. (author). 5 refs., 3 figs

  6. A new tool to measure training load in soccer training and match play

    DEFF Research Database (Denmark)

    Rebelo, A; Brito, J; Seabra, A

    2012-01-01

    -based methods (TRIMP and Edwards' method). 51 soccer players (age 15.6±0.3 years) answered 2 questions to assess perceived exertion and fatigue (VAS1-TL, and VAS2-TL) after training sessions and official matches. Performance in the Yo-Yo tests, VAS scores and heart rate of training sessions and matches......An accurate evaluation of training load is paramount for the planning and periodization of training. The aim of the present study was to evaluate the relationship between a new method to monitor training load in soccer (Visual Analogic Scale training load; VAS-TL), and two established heart rate...

  7. Load monitoring program: Status and results report. Volume 1: Summary

    International Nuclear Information System (INIS)

    1994-06-01

    British Columbia Hydro conducts a monitoring program to provide information on customer needs and values for planning; to measure customer response, energy savings impacts, and load shape impacts due to changes in rate level, rate restructuring, and Power Smart programs; to estimate end-use consumption and load shapes by customer class; and to provide load information for distribution and system load studies. To achieve these objectives, the monitoring program tracks the characteristics and energy use patterns of a sample of BC Hydro residential, commercial, and industrial customers over a period of several years. The entire sample will be surveyed periodically to obtain information on changes in building characteristics, equipment stocks, and energy-use behavior and attitudes. A report is provided on the status of monitoring program activities and some results obtained in 1993/94. For the residential sector, the results include typical load profiles, end-user demographics, and extent of electric space heating and water heating. In the commercial sector, customers were divided into two main groups. The large-building group was relatively well organized in terms of energy needs and participated in Power Smart programs. The small-building group was relatively energy-inefficient and relatively unaware of Power Smart programs. 43 figs., 15 tabs

  8. Exploratory Investigation of Impact Loads During the Forward Handspring Vault

    Directory of Open Access Journals (Sweden)

    Penitente Gabriella

    2015-06-01

    Full Text Available The purpose of this study was to examine kinematic and kinetic differences in low and high intensity hand support impact loads during a forward handspring vault. A high-speed video camera (500 Hz and two portable force platforms (500 Hz were installed on the surface of the vault table. Two-dimensional analyses were conducted on 24 forward handspring vaults performed by 12 senior level, junior Olympic program female gymnasts (16.9 ±1.4 yr; body height 1.60 ±0.1 m; body mass 56.7 ±7.8 kg. Load intensities at impact with the vault table were classified as low (peak force 0.8 × body weight. These vaults were compared via crucial kinetic and kinematic variables using independent t-tests and Pearson correlations. Statistically significant (p < 0.001 differences were observed in peak force (t(24 = 4.75, ES = 3.37 and time to peak force (t(24 = 2.07, ES = 1.56. Statistically significant relationships between the loading rate and time to peak force were observed for high intensity loads. Peak force, time to peak force, and a shoulder angle at impact were identified as primary variables potentially involved in the determination of large repetitive loading rates on the forward handspring vault.

  9. A pulsed load model and its impact on a synchronous-rectifier system

    Science.gov (United States)

    Hou, Pengfei; Xu, Ye; Li, Jianke; Wang, Jinquan; Zhang, Haitao; Yan, Jun; Wang, Chunming; Chen, Jingjing

    2017-02-01

    The pulsed load has become a developing trend of power loading. Unlike traditional loads, pulsed loads with current abrupt and repeated charges will result in unstable Microgrid operations because of their small capacity and inertia. In this paper, an Average Magnitude Sum Function (AMSF) is proposed to calculate the frequency of the grid, and based on AMSF, the Relative Deviation Rate (RDR) that characterises the impact of pulsed load on the AC side of the grid is defined and its calculation process is described in detail. In addition, the system dynamic characteristics under a pulsed load are analysed using an Insulated Gate Bipolar Transistor (IGBT) to control the on/off state of the resistive load for simulating a pulsed load. Finally, the transient characteristics of a synchronous-rectifier system with a pulsed load are studied and validated experimentally.

  10. Load reduction test method of similarity theory and BP neural networks of large cranes

    Science.gov (United States)

    Yang, Ruigang; Duan, Zhibin; Lu, Yi; Wang, Lei; Xu, Gening

    2016-01-01

    Static load tests are an important means of supervising and detecting a crane's lift capacity. Due to space restrictions, however, there are difficulties and potential danger when testing large bridge cranes. To solve the loading problems of large-tonnage cranes during testing, an equivalency test is proposed based on the similarity theory and BP neural networks. The maximum stress and displacement of a large bridge crane is tested in small loads, combined with the training neural network of a similar structure crane through stress and displacement data which is collected by a physics simulation progressively loaded to a static load test load within the material scope of work. The maximum stress and displacement of a crane under a static load test load can be predicted through the relationship of stress, displacement, and load. By measuring the stress and displacement of small tonnage weights, the stress and displacement of large loads can be predicted, such as the maximum load capacity, which is 1.25 times the rated capacity. Experimental study shows that the load reduction test method can reflect the lift capacity of large bridge cranes. The load shedding predictive analysis for Sanxia 1200 t bridge crane test data indicates that when the load is 1.25 times the rated lifting capacity, the predicted displacement and actual displacement error is zero. The method solves the problem that lifting capacities are difficult to obtain and testing accidents are easily possible when 1.25 times related weight loads are tested for large tonnage cranes.

  11. Tsüklist "Spoon Riveri koolnud" : [luuletused] / Edgar Lee Masters ; tõlk. Boris Kabur

    Index Scriptorium Estoniae

    Masters, Edgar Lee

    2008-01-01

    Sisu: Poeet Theodore ; Lucinda Matlock ; Willard Fluke ; Diakon Taylor ; Viiuldaja Jones ; Dora Williams ; John M. Church ; Vene Sonja ; Petit, poeet ; Pastor Abner Peet ; Yee Bow ; Roger Heston ; Carl Hamblin ; Hortense Robbins ; Tom Merritt ; Proua Merritt ; Elmer Karr ; Anne Rutledge ; Marie Bateson ; Scholfield Huxley ; Willie Metcalf. Elu- ja loomeloolisi andmeid autori kohta lk. 519-520

  12. Novel toggle-rate based energy-efficient scheme for heavy load real-time IM-DD OFDM-PON with ONU LLID identification in time-domain using amplitude decision.

    Science.gov (United States)

    Qin, Youxiang; Zhang, Junjie

    2017-07-10

    A novel low complexity and energy-efficient scheme by controlling the toggle-rate of ONU with time-domain amplitude identification is proposed for a heavy load downlink in an intensity-modulation and direct-detection orthogonal frequency division multiplexing passive optical network (IM-DD OFDM-PON). In a conventional OFDM-PON downlink, all ONUs have to perform demodulation for all the OFDM frames in a broadcast way no matter whether the frames are targeted to or not, which causes a huge energy waste. However, in our scheme, the optical network unit (ONU) logical link identifications (LLIDs) are inserted into each downlink OFDM frame in time-domain at the optical line terminal (OLT) side. At the ONU side, the LLID is obtained with a low complexity and high precision amplitude identification method. The ONU sets the toggle-rate of demodulation module to zero when the frames are not targeted to, which avoids unnecessary digital signal processing (DSP) energy consumption. Compared with the sleep-mode methods consisting of clock recovery and synchronization, toggle-rate shows its advantage in fast changing, which is more suitable for the heavy load scenarios. Moreover, for the first time to our knowledge, the characteristics of the proposed scheme are investigated in a real-time IM-DD OFDM system, which performs well at the received optical power as low as -21dBm. The experimental results show that 25.1% energy consumption can be saved in the receiver compared to the conventional configurations.

  13. Effects of organic loading rates on reactor performance and microbial community changes during thermophilic aerobic digestion process of high-strength food wastewater.

    Science.gov (United States)

    Jang, Hyun Min; Lee, Jae Won; Ha, Jeong Hyub; Park, Jong Moon

    2013-11-01

    To evaluate the applicability of single-stage thermophilic aerobic digestion (TAD) process treating high-strength food wastewater (FWW), TAD process was operated at four organic loading rates (OLRs) from 9.2 to 37.2 kg COD/m(3)d. The effects of OLRs on microbial community changes were also examined. The highest volumetric removal rate (13.3 kg COD/m(3)d) and the highest thermo-stable protease activity (0.95 unit/mL) were detected at OLR=18.6 kg COD/m(3)d. Denaturing gradient gel electrophoresis (DGGE) profiles and quantitative PCR (qPCR) results showed significant microbial community shifts in response to changes in OLR. In particular, DGGE and phylogenetic analysis demonstrate that the presence of Bacillus sp. (phylum of Firmicutes) was strongly correlated with efficient removal of organic particulates from high-strength food wastewater. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Anaerobic co-digestion of cheese whey and the screened liquid fraction of dairy manure in a single continuously stirred tank reactor process: Limits in co-substrate ratios and organic loading rate.

    Science.gov (United States)

    Rico, Carlos; Muñoz, Noelia; Rico, José Luis

    2015-01-01

    Mesophilic anaerobic co-digestion of cheese whey and the screened liquid fraction of dairy manure was investigated with the aim of determining the treatment limits in terms of the cheese whey fraction in feed and the organic loading rate. The results of a continuous stirred tank reactor that was operated with a hydraulic retention time of 15.6 days showed that the co-digestion process was possible with a cheese whey fraction as high as 85% in the feed. The efficiency of the process was similar within the range of the 15-85% cheese whey fraction. To study the effect of the increasing loading rate, the HRT was progressively shortened with the 65% cheese whey fraction in the feed. The reactor efficiency dropped as the HRT decreased but enabled a stable operation over 8.7 days of HRT. At these operating conditions, a volumetric methane production rate of 1.37 m(3) CH4 m(-3) d(-1) was achieved. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Self-organized dynamics in local load-sharing fiber bundle models.

    Science.gov (United States)

    Biswas, Soumyajyoti; Chakrabarti, Bikas K

    2013-10-01

    We study the dynamics of a local load-sharing fiber bundle model in two dimensions under an external load (which increases with time at a fixed slow rate) applied at a single point. Due to the local load-sharing nature, the redistributed load remains localized along the boundary of the broken patch. The system then goes to a self-organized state with a stationary average value of load per fiber along the (increasing) boundary of the broken patch (damaged region) and a scale-free distribution of avalanche sizes and other related quantities are observed. In particular, when the load redistribution is only among nearest surviving fiber(s), the numerical estimates of the exponent values are comparable with those of the Manna model. When the load redistribution is uniform along the patch boundary, the model shows a simple mean-field limit of this self-organizing critical behavior, for which we give analytical estimates of the saturation load per fiber values and avalanche size distribution exponent. These are in good agreement with numerical simulation results.

  16. Thermal and mechanical cyclic loading of thick spherical vessels made of transversely isotropic materials

    International Nuclear Information System (INIS)

    Komijani, M.; Mahbadi, H.; Eslami, M.R.

    2013-01-01

    The aim of this paper is to obtain the dependency of the ratcheting, reversed plasticity, or shakedown behavior of spherical vessels made of some anisotropic materials to the stress category of imposed cyclic loading. The Hill anisotropic yield criterion with the kinematic hardening theories of plasticity based on the Prager and Armstrong–Frederick models are used to predict the yield of the vessel and obtain the plastic strains. An iterative numerical method is used to simulate the cyclic loading behavior of the structure. The effect of mean and amplitude of the mechanical and thermal loads on cyclic behavior and ratcheting rate of the vessel is investigated respectively. The ratcheting rate for the vessels made of transversely isotropic material is evaluated for the various ratios of anisotropy. -- Highlights: ► Cyclic loading analysis of anisotropic spheres is assessed. ► Using the Prager model results in ratcheting. ► Armstrong-Frederick model predicts ratcheting for load controlled cyclic loadings. ► The A-F model predicts ratcheting to a stabilized cycle for thermal loadings

  17. Minor actinides incineration by loading moderated targets in fast reactor

    International Nuclear Information System (INIS)

    Wu Hongchun; Sato, Daisuke; Takeda, Toshikazu

    2000-01-01

    The effect of hydrogen concentration and loaded mass of minor actinides (MAs) in the target on the core performance and MAs transmutation rate was analyzed in this paper. An optimum core was proposed which has 96 MAs target assemblies of which MAs fuel pins per assembly is 38 with the composition ratio U/MA/Zr/H of 1/4/10/50. This optimized core offers good core performance and can transmute MAs very effectively, the transmutation rate was about 67% (939 kg) and the incinerate (transmute by fission) rate was about 35% (489 kg) through 3 years of reactor operation. It is about 2-3 times larger than current transmutation method that MAs are loaded homogeneously in the PWR and fast reactor core. (author)

  18. PASSIVE DETECTION OF VEHICLE LOADING

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, A.

    2012-01-03

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  19. Passive detection of vehicle loading

    Science.gov (United States)

    McKay, Troy R.; Salvaggio, Carl; Faulring, Jason W.; Salvaggio, Philip S.; McKeown, Donald M.; Garrett, Alfred J.; Coleman, David H.; Koffman, Larry D.

    2012-01-01

    The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

  20. Accident loads for a VVER-440/213 containment

    Energy Technology Data Exchange (ETDEWEB)

    Techy, Z. [Institute for Electric Power Research (VEIKI), Budapest (Hungary); Lajtha, G. [Institute for Electric Power Research (VEIKI), Budapest (Hungary); Taubner, R. [Institute for Electric Power Research (VEIKI), Budapest (Hungary)

    1995-08-01

    Specific features of the VVER-440/213 containment are the subdivided rectangular building and the localization system including the bubbler trays and air traps. Accident loads are calculated for a large break loss of coolant accident (LBLOCA). The maximum pressure and temperature loads are calculated with different codes during the blowdown phase of the LBLOCA. The uncertainty margins of the maximum pressure are given in this case. Sensitivity studies are performed for different leakage rates and hydraulic data of the containment. The effects of the active and passive spray systems on the depressurization are presented in this paper. The maximum pressure loads are also examined in case of degraded conditions of the localization system. (orig.).

  1. Optimization of enhanced biological phosphorus removal after periods of low loading.

    Science.gov (United States)

    Miyake, Haruo; Morgenroth, Eberhard

    2005-01-01

    Enhanced biological phosphorus removal is a well-established technology for the treatment of municipal wastewater. However, increased effluent phosphorus concentrations have been reported after periods (days) of low organic loading. The purpose of this study was to evaluate different operating strategies to prevent discharge of effluent after such low-loading periods. Mechanisms leading to these operational problems have been related to the reduction of polyphosphate-accumulating organisms (PAOs) and their storage compounds (polyhydroxy alkanoates [PHA]). Increased effluent phosphorus concentrations can be the result of an imbalance between influent loading and PAOs in the system and an imbalance between phosphorus release and uptake rates. The following operating conditions were tested in their ability to prevent a reduction of PHA and of overall biomass during low organic loading conditions: (a) unchanged operation, (b) reduced aeration time, (c) reduced sludge wastage, and (d) combination of reduced aeration time and reduced sludge wastage. Experiments were performed in a laboratory-scale anaerobic-aerobic sequencing batch reactor, using acetate as the carbon source. Without operational adjustments, phosphorus-release rates decreased during low-loading periods but recovered rapidly. Phosphorus-uptake rates also decreased, and the recovery typically required several days to increase to normal levels. The combination of reduced aeration time and reduced sludge wastage allowed the maintenance of constant levels of both PHA and overall biomass. A mathematical model was used to explain the influence of the tested operating conditions on PAO and PHA concentrations. While experimental results were in general agreement with model predictions, the kinetic expression for phosphorus uptake deviated significantly for the first 24 hours after low-loading conditions. Mechanisms leading to these deviations need to be further investigated.

  2. Contact-Free Cognitive Load Recognition Based on Eye Movement

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2016-01-01

    Full Text Available The cognitive overload not only affects the physical and mental diseases, but also affects the work efficiency and safety. Hence, the research of measuring cognitive load has been an important part of cognitive load theory. In this paper, we proposed a method to identify the state of cognitive load by using eye movement data in a noncontact manner. We designed a visual experiment to elicit human’s cognitive load as high and low state in two light intense environments and recorded the eye movement data in this whole process. Twelve salient features of the eye movement were selected by using statistic test. Algorithms for processing some features are proposed for increasing the recognition rate. Finally we used the support vector machine (SVM to classify high and low cognitive load. The experimental results show that the method can achieve 90.25% accuracy in light controlled condition.

  3. Dynamic Response and Failure Mechanism of Brittle Rocks Under Combined Compression-Shear Loading Experiments

    Science.gov (United States)

    Xu, Yuan; Dai, Feng

    2018-03-01

    A novel method is developed for characterizing the mechanical response and failure mechanism of brittle rocks under dynamic compression-shear loading: an inclined cylinder specimen using a modified split Hopkinson pressure bar (SHPB) system. With the specimen axis inclining to the loading direction of SHPB, a shear component can be introduced into the specimen. Both static and dynamic experiments are conducted on sandstone specimens. Given carefully pulse shaping, the dynamic equilibrium of the inclined specimens can be satisfied, and thus the quasi-static data reduction is employed. The normal and shear stress-strain relationships of specimens are subsequently established. The progressive failure process of the specimen illustrated via high-speed photographs manifests a mixed failure mode accommodating both the shear-dominated failure and the localized tensile damage. The elastic and shear moduli exhibit certain loading-path dependence under quasi-static loading but loading-path insensitivity under high loading rates. Loading rate dependence is evidently demonstrated through the failure characteristics involving fragmentation, compression and shear strength and failure surfaces based on Drucker-Prager criterion. Our proposed method is convenient and reliable to study the dynamic response and failure mechanism of rocks under combined compression-shear loading.

  4. Loss and thermal model for power semiconductors including device rating information

    DEFF Research Database (Denmark)

    Ma, Ke; Bahman, Amir Sajjad; Beczkowski, Szymon

    2014-01-01

    The electrical loading and device rating are both important factors that determine the loss and thermal behaviors of power semiconductor devices. In the existing loss and thermal models, only the electrical loadings are focused and treated as design variables, while the device rating is normally...

  5. Rod behaviour under base load, load follow and frequency control operation: CYRANO 2 code predictions versus experimental results

    International Nuclear Information System (INIS)

    Gautier, B.; Raybaud, A.

    1984-01-01

    The French PWR reactors are now currently operating under load follow and frequency control. In order to demonstrate that these operating conditions were not able to increase the fuel failure rate, fuel rod behaviour calculations have been performed by E.D.F. with CYRANO 2 code. In parallel with these theoretical calculations, code predictions have been compared to experimental results. The paper presents some of the comparisons performed on 17x17 fuel irradiated in FESSENHEIM 2 up to 30 GWd/tU under base load operation and in the CAP reactor under load follow and frequency control conditions. It is shown that experimental results can be predicted with a reasonable accuracy by CYRANO 2 code. The experimental work was carried out under joint R and D programs by EDF, FRAGEMA, CEA, and WESTINGHOUSE (CAP program by French partners only). (author)

  6. Mechanical properties of stanene under uniaxial and biaxial loading: A molecular dynamics study

    Energy Technology Data Exchange (ETDEWEB)

    Mojumder, Satyajit [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka 1000 (Bangladesh); Amin, Abdullah Al [Department of Mechanical and Aerospace Engineering, Case western Reverse University, Cleveland, Ohio 44106 (United States); Islam, Md Mahbubul, E-mail: mmi122@psu.edu [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802 (United States)

    2015-09-28

    Stanene, a graphene like two dimensional honeycomb structure of tin has attractive features in electronics application. In this study, we performed molecular dynamics simulations using modified embedded atom method potential to investigate mechanical properties of stanene. We studied the effect of temperature and strain rate on mechanical properties of α-stanene for both uniaxial and biaxial loading conditions. Our study suggests that with the increasing temperature, both the fracture strength and strain of the stanene decrease. Uniaxial loading in zigzag direction shows higher fracture strength and strain compared to the armchair direction, while no noticeable variation in the mechanical properties is observed for biaxial loading. We also found at a higher loading rate, material exhibits higher fracture strength and strain. These results will aid further investigation of stanene as a potential nano-electronics substitute.

  7. The durability of waveguide fibers at cyclic change of loading, temperature and humidity

    International Nuclear Information System (INIS)

    Karimov, S.N.; Sultonov, U.; Shamsidinov, M.I.

    1992-01-01

    Present article is devoted to durability of waveguide fibers at cyclic change of loading, temperature and humidity. The mounting scheme and loading of sample is presented. The dependence of glass fiber durability on number of thermal cycles at various humidity rates was considered. The dependence of number of cycles on maximal loading at cyclic temperature change was studied.

  8. Two efficient heuristics to solve the integrated load distribution and production planning problem

    International Nuclear Information System (INIS)

    Gajpal, Yuvraj; Nourelfath, Mustapha

    2015-01-01

    This paper considers a multi-period production system where a set of machines are arranged in parallel. The machines are unreliable and the failure rate of machine depends on the load assigned to the machine. The expected production rate of the system is considered to be a non-monotonic function of its load. Because of the machine failure rate, the total production output depends on the combination of loads assigned to different machines. We consider the integration of load distribution decisions with production planning decision. The product demands are considered to be known in advance. The objective is to minimize the sum of holding costs, backorder costs, production costs, setup costs, capacity change costs and unused capacity costs while satisfying the demand over specified time horizon. The constraint is not to exceed available repair resources required to repair the machine breakdown. The paper develops two heuristics to solve the integrated load distribution and production planning problem. The first heuristic consists of a three-phase approach, while the second one is based on tabu search metaheuristic. The efficiency of the proposed heuristics is tested through the randomly generated problem instances. - Highlights: • The expected performance of the system is a non-monotonic function of its load. • We consider the integration of load distribution and production planning decisions. • The paper proposes three phase and tabu search based heuristics to solve the problem. • Lower bound has been developed for checking the effectiveness of the heuristics. • The efficiency of the heuristic is tested through randomly generated instances.

  9. Load theory behind the wheel; perceptual and cognitive load effects.

    Science.gov (United States)

    Murphy, Gillian; Greene, Ciara M

    2017-09-01

    Perceptual Load Theory has been proposed as a resolution to the longstanding early versus late selection debate in cognitive psychology. There is much evidence in support of Load Theory but very few applied studies, despite the potential for the model to shed light on everyday attention and distraction. Using a driving simulator, the effect of perceptual and cognitive load on drivers' visual search was assessed. The findings were largely in line with Load Theory, with reduced distractor processing under high perceptual load, but increased distractor processing under high cognitive load. The effect of load on driving behaviour was also analysed, with significant differences in driving behaviour under perceptual and cognitive load. In addition, the effect of perceptual load on drivers' levels of awareness was investigated. High perceptual load significantly increased inattentional blindness and deafness, for stimuli that were both relevant and irrelevant to driving. High perceptual load also increased RTs to hazards. The current study helps to advance Load Theory by illustrating its usefulness outside of traditional paradigms. There are also applied implications for driver safety and roadway design, as the current study suggests that perceptual and cognitive load are important factors in driver attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Degradation of normal portland and slag cement concrete under load, due to reinforcement corrosion

    International Nuclear Information System (INIS)

    Philipose, K.E.; Beaudoin, J.J.; Feldman, R.F.

    1992-08-01

    The corrosion of reinforcement is one of the major degradation mechanisms of reinforced concrete elements. The majority of studies published on concrete-steel corrosion have been conducted on unstressed specimens. Structural concrete, however, is subjected to substantial strain near the steel reinforcing bars that resist tensile loads, which results in a system of microcracks. This report presents the initial results of an investigation to determine the effect of applied load and microcracking on the rate of ingress of chloride ion and corrosion of steel in concrete. Simply-supported concrete beam specimens were loaded to give a maximum strain of about 600 με on the tension face. Chloride ion ingress on cores taken from loaded specimens was monitored using energy-dispersive X-ray analysis techniques. Corrosion current and rate measurements using linear polarization electrochemical techniques were also obtained on the same loaded specimens. Variables investigated included two concrete types, two steel cover-depths, three applied load levels, bonded and unbonded rebars and the exposure of tension and compression beam faces to chloride solution. One concrete mixture was made with type 10 Portland cement, the other with 75% blast furnace slag, 22% type 50 cement and 3% silica fume. The rate of chloride ion ingress into reinforced concrete, and hence the time for chloride ion to reach the reinforcing steel, is shown to be dependent on applied load and the concrete quality. The dependence of corrosion process descriptors - passive layer formation, initiation period and propagation period - on the level of applied load is discussed. (Author) (6 refs., 3 tabs., 10 figs.)

  11. Full State Estimation for Helicopter Slung Load System

    DEFF Research Database (Denmark)

    Bisgaard, Morten; la Cour-Harbo, Anders; Bendtsen, Jan Dimon

    This paper presents the design of a state estimator system for a generic helicopter based slung load system. The estimator is designed to deliver full rigid body state information for both helicopter and load and is based on the unscented Kalman filter. Two different approaches are investigated......: One based on a parameter free kinematic model and one based on a full aerodynamic helicopter and slung load model. The kinematic model approach uses acceleration and rate information from two Inertial Measurement Units, one on the helicopter and one on the load, to drive a simple kinematic model....... A simple and effective virtual sensor method is developed to maintain the constraints imposed by the wires in the system. The full model based approach uses a complex aerodynamical model to describe the helicopter together with a generic rigid body model. This rigid body model is based on a redundant...

  12. Full State Estimation for Helicopter Slung Load System

    DEFF Research Database (Denmark)

    Bisgaard, Morten; la Cour-Harbo, Anders; Bendtsen, Jan Dimon

    2007-01-01

    This paper presents the design of a state estimator system for a generic helicopter based slung load system. The estimator is designed to deliver full rigid body state information for both helicopter and load and is based on the unscented Kalman filter. Two different approaches are investigated......: One based on a parameter free kinematic model and one based on a full aerodynamic helicopter and slung load model. The kinematic model approach uses acceleration and rate information from two Inertial Measurement Units, one on the helicopter and one on the load, to drive a simple kinematic model....... A simple and effective virtual sensor method is developed to maintain the constraints imposed by the wires in the system. The full model based approach uses a complex aerodynamical model to describe the helicopter together with a generic rigid body model. This rigid body model is based on a redundant...

  13. Organic loading rate effect on the acidogenesis of cheese whey: a comparison between UASB and SBR reactors.

    Science.gov (United States)

    Calero, R; Iglesias-Iglesias, R; Kennes, C; Veiga, M C

    2017-09-16

    Volatile fatty acids (VFA) production and degree of acidification (DA) were investigated in the anaerobic treatment of cheese whey by comparison of two processes: a continuous process using a laboratory upflow anaerobic sludge blanket (UASB) reactor and a discontinuous process using a sequencing batch reactor (SBR). The main purpose of this work was to study the organic loading rate (OLR) effect on the yield of VFA in two kinds of reactors. The predominant products in the acidogenic process in both reactors were: acetate, propionate, butyrate and valerate. The maximum DA obtained was 98% in an SBR at OLR of 2.7 g COD L -1 d -1 , and 97% in the UASB at OLR at 15.1 g COD L -1 d -1 . The results revealed that the UASB reactor was more efficient at a medium OLR with a higher VFA yield, while with the SBR reactor, the maximum acidification was obtained at a lower OLR with changes in the VFA profile at different OLRs applied.

  14. A Feast of Malaria Parasite Genomes.

    Science.gov (United States)

    Carlton, Jane M; Sullivan, Steven A

    2017-03-08

    The Plasmodium genus has evolved over time and across hosts, complexifying our understanding of malaria. In a recent Nature paper, Rutledge et al. (2017) describe the genome sequences of three major human malaria parasite species, providing insight into Plasmodium evolution and raising the question of how many species there are. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve

    International Nuclear Information System (INIS)

    Sonoda, Akinaga; Nitta, Norihisa; Yamamoto, Takefumi; Tomozawa, Yuki; Ohta, Shinichi; Watanabe, Shobu; Murata, Kiyoshi

    2017-01-01

    PurposeWe investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads ® ) to be used for transarterial chemoembolization.MethodAfter separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.ResultsSpectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.DiscussionThe use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.

  16. The frequency effect on the fatigue crack growth rate of 304 stainless steel

    International Nuclear Information System (INIS)

    Shih, Y.-S.; Chen, J.-J.

    1999-01-01

    Under cyclic loading condition, the fatigue crack growth (FCG) rate governed by stress intensity factor and stress ratio is well known; Walker's equation, Forman's equation and Elber's equation are typical formulae to describe the fatigue crack growth rate. However, the loading frequency effect on the fatigue crack growth rate has yet to be explored. Recently, studies have focused on the loading frequency effect on some visco-elastic materials, and have provided a clearer understanding of the frequency effect on the fatigue crack growth rate. In a physical sense, knowledge about the loading frequency effect on the fatigue crack growth rate for 304 stainless steel is still lacking. James conducted a lot of experiments, and through data analysis, he concluded an evaluation equation which is based upon the experimental illustration. In this study, the physical properties of the material are used to illustrate the modification of fatigue crack growth rate, and a new formula which is based upon the modified Forman's equation, is provided. (orig.)

  17. The flow field investigations of no load conditions in axial flow fixed-blade turbine

    Science.gov (United States)

    Yang, J.; Gao, L.; Wang, Z. W.; Zhou, X. Z.; Xu, H. X.

    2014-03-01

    During the start-up process, the strong instabilities happened at no load operation in a low head axial flow fixed-blade turbine, with strong pressure pulsation and vibration. The rated speed can not reach until guide vane opening to some extent, and stable operation could not be maintained under the rated speed at some head, which had a negative impact on the grid-connected operation of the unit. In order to find the reason of this phenomenon, the unsteady flow field of the whole flow passage at no load conditions was carried out to analyze the detailed fluid field characteristics including the pressure pulsation and force imposed on the runner under three typical heads. The main hydraulic cause of no load conditions instability was described. It is recommended that the power station should try to reduce the no-load running time and go into the high load operation as soon as possible when connected to grid at the rated head. Following the recommendations, the plant operation practice proved the unstable degree of the unit was reduced greatly during start up and connect to the power grid.

  18. Load levelling measures being tackled by shikoku Electric Power Co. Inc.; Shikoku Denryoku Kabushi Kaisha no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    For the electric power companies, the activity of pushing forward the load levelling contributes greatly to the curtailment of cost by means of effective formation and utilization of facilities. It is planned to take up more positive activities with a target of 3% improvement in the load factor in ten years. Concrete measures for further promotion of load levelling are the diversity of the rate menu of appraising the load levelling effort of the customers and the promotion of the spread of equipment and systems relating to load levelling such as electric water heating apparatuses and thermal energy storage air conditioning systems. The rate system has been reviewed taking the opportunity of rate revision made in January, 1996. Particularly, further load shift to midnight time zone is expected as a result of better rate incentive for customers which is brought about by large reduction of the rate level due to the cost reduction effect accompanying the improvement in atomic power generation ratio. Outlines are given on the fields relating to general households, business, dwellings, buildings, and industry. 3 figs., 1 tab.

  19. Opposite effects of capacity load and resolution load on distractor processing.

    Science.gov (United States)

    Zhang, Weiwei; Luck, Steven J

    2015-02-01

    According to the load theory of attention, an increased perceptual load reduces distractor processing whereas an increased working memory load facilitates distractor processing. Here we raise the possibility that the critical distinction may instead be between an emphasis on resolution and an emphasis on capacity. That is, perceptual load manipulations typically emphasize resolution (fine-grained discriminations), whereas working memory load manipulations typically emphasize capacity (simultaneous processing of multiple relevant stimuli). To test the plausibility of this hypothesis, we used a visual working memory task that emphasized either the number of items to be stored (capacity load, retaining 2 vs. 4 colors) or the precision of the representations (resolution load, detecting small vs. large color changes). We found that an increased capacity load led to increased flanker interference (a measure of distractor processing), whereas an increased resolution load led to reduced flanker interference. These opposite effects of capacity load and resolution load on distractor processing mirror the previously described opposite effects of perceptual load and working memory load.

  20. Thermophilic co-digestion feasibility of distillers grains and swine manure: effect of C/N ratio and organic loading rate during high solid anaerobic digestion (HSAD).

    Science.gov (United States)

    Sensai, P; Thangamani, A; Visvanathan, C

    2014-01-01

    Anaerobic co-digestion of high solids containing distillers grains and swine manure (total solids, 27 +/- 2% and 18 +/- 2%, respectively) was evaluated in this study to assess the effect of C/N ratio and organic loading rate (OLR). Feed mixture was balanced to achieve a C/N ratio of 30/1 by mixing distillers grains and swine manure. Pilot-scale co-digestion of distillers grains and swine manure was carried out under thermophilic conditions in the continuous mode for seven different OLRs from R1 to R7 (3.5, 5, 6, 8, 10, 12 and 14 kg VS/m3 day) under high solid anaerobic digestion. The methane yield and volatile solid (VS) removal were consistent; ranging from 0.33 to 0.34 m3CH4/kg VS day and 50-53%, respectively, until OLR 8 kg VS/m3 day. After which methane yield and VS removal significantly decreased to 0.26 m3 CH4/kg VS day and 42%, respectively, when OLR was increased to 14 kg VS/m3 day. However, during operation, at OLR of 10 kg VS/m3 day, the methane yield and VS removal increased after the 19th day to 0.33 m3 CH4/kg VS day and 46%, respectively, indicating that a longer acclimatization period is required by methanogens at a higher loading rate.

  1. Locomotion With Loads: Practical Techniques for Predicting Performance Outcomes

    Science.gov (United States)

    2015-05-01

    Metabolic energy consumption as a function of speed and body size in birds and mammals. J Exp Biol. 97, 1-21. Weyand, P., Smith, B., Puyau, M. and...height, weight (including load), speed, and grade algorithms proposed will allow walking metabolic rates to be predicted to within 6.0 and 12.0% in...gait, metabolism , performance, load carriage 16. SECURITY CLASSIFICATION OF: Unclassified 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME

  2. Load testing circuit

    DEFF Research Database (Denmark)

    2009-01-01

    A load testing circuit a circuit tests the load impedance of a load connected to an amplifier. The load impedance includes a first terminal and a second terminal, the load testing circuit comprising a signal generator providing a test signal of a defined bandwidth to the first terminal of the load...

  3. Nutrient load estimates for Manila Bay, Philippines using population data

    Science.gov (United States)

    Sotto, Lara Patricia A.; Beusen, Arthur H. W.; Villanoy, Cesar L.; Bouwman, Lex F.; Jacinto, Gil S.

    2015-06-01

    A major source of nutrient load to periodically hypoxic Manila Bay is the urban nutrient waste water flow from humans and industries to surface water. In Manila alone, the population density is as high as 19,137 people/km2. A model based on a global point source model by Morée et al. (2013) was used to estimate the contribution of the population to nitrogen and phosphorus emissions which was then used in a water transport model to estimate the nitrogen (N) and phosphorus (P) loads to Manila Bay. Seven scenarios for 2050 were tested, with varying degrees and amounts for extent of sewage treatment, and population growth rates were also included. In scenario 1, the sewage connection and treatment remains the same as 2010; in scenario 2, sewage connection is improved but the treatment is the same; in scenario 3, the sewage connection as well as treatment is improved (70% tertiary); and in scenario 4, a more realistic situation of 70% primary treatment achieved with 100% connection to pipes is tested. Scenarios 5, 6, and 7 have the same parameters as 1, 2, and 3 respectively, but with the population growth rate per province reduced to half of what was used in 1, 2, and 3. In all scenarios, a significant increase in N and P loads was observed (varying from 27% to 469% relative to 2010 values). This was found even in scenario 3 where 70% of the waste water undergoes tertiary treatment which removes 80% N and 90% P. However, the lowest increase in N and P load into the bay was achieved in scenarios 5 to 7 where population growth rate is reduced to half of 2010 values. The results suggest that aside from improving sewage treatment, the continued increase of the human population in Manila at current growth rates will be an important determinant of N and P load into Manila Bay.

  4. Unravelling the relative contribution of bed and suspended sediment load on a large alluvial river

    Science.gov (United States)

    Darby, S. E.; Hackney, C. R.; Parsons, D. R.; Leyland, J.; Aalto, R. E.; Nicholas, A. P.; Best, J.

    2017-12-01

    The world's largest rivers transport 19 billion tonnes of sediment to the coastal zone annually, often supporting large deltas that rely on this sediment load to maintain their elevation in the face of rising sea level, and to sustain high levels of agricultural productivity and biodiversity. However, the majority of estimates of sediment delivery to coastal regions pertain solely to the suspended fraction of the sediment load, with the bedload fraction often being neglected due to the difficulty in estimating bedload flux and the assumption that bedload contributes a minor (management plans, improved estimates of all fractions of the sediment load are essential. Recent advances in non-intrusive, high-resolution, technology have begun to enable more accurate estimates of bedload transport rates. However, the characterisation of the holistic sediment transport regime of large alluvial rivers is still lacking. Here, we develop a sediment transport rating curve, combining both suspended- and bed- load sediment fractions, for the Lower Mekong River. We define suspended sediment rating curves using the inversion of acoustic return data from a series of acoustic Doppler current profiler surveys conducted through the Lower Mekong River in Cambodia, and into the bifurcating channels of the Mekong delta in Vietnam. Additionally, we detail estimates of bed-load sediment transport determined using repeat multibeam echo sounder surveys of the channel bed. By combining estimates of both fractions of the sediment load, we show the spatial and temporal contribution of bedload to the total sediment load of the Mekong and refine estimates of sediment transport to the Mekong delta. Our results indicate that the time-averaged suspended load transport rates for the Mekong River are 87 MT/yr, whilst bedload transport forms c. management within this highly threatened river basin.

  5. Strength of wood versus rate of testing - A theoretical approach

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    2007-01-01

    Strength of wood is normally measured in ramp load experiments. Experience shows that strength increases with increasing rate of testing. This feature is considered theoretically in this paper. It is shown that the influence of testing rate is a phenomenon, which depends on the quality...... of the considered wood. Low quality wood shows lesser influence of testing rate. This observation agrees with the well-known statement made by Borg Madsen that weak wood subjected to a constant load, has a longer lifetime than strong wood. In general, the influence of testing rate on strength increases...

  6. Dynamics of HPV viral loads reflect the treatment effect of photodynamic therapy in genital warts.

    Science.gov (United States)

    Hu, Zhili; Liu, Lishi; Zhang, Wenjing; Liu, Hui; Li, Junpeng; Jiang, Lifen; Zeng, Kang

    2018-03-01

    Photodynamic therapy (PDT) has demonstrated good clinical cure rates and low recurrence rates in the treatment of genital warts. Human papillomavirus (HPV) genotypes and viral load assays can reflect the status of persistent or latent infection and serve as a predictor of infection clearance. Specimens from 41 patients with HPV infection were obtained, and the HPV genotypes and viral load were analyzed using real-time polymerase chain reaction (PCR) assays. Traditional treatment, such as radiofrequency, microwave, or surgical therapy, was used to remove the visible lesions, and then PDT treatment was performed every week. HPV DNA testing was performed at every patient visit and the frequency of PDT treatment was determined by changes in HPV viral loads. HPV viral loads decreased significantly after PDT treatment. There were significant differences in HPV viral loads between pretherapy and three or six rounds of PDT treatment. Significant differences were also observed between single and multiple type HPV infection after six rounds of PDT treatment. Patients with single type HPV infection had significantly higher rates of negative HPV DNA test results, as compared with patients with multiple infections after six rounds of PDT treatment; however, there was no difference in recurrence rates between the two groups. Dynamic monitoring of HPV genotypes and viral loads can be used to guide PDT treatment and indicate PDT treatment efficacy in eliminating HPV. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. 46 CFR 154.1730 - Ethylene oxide: Loading and off loading.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Ethylene oxide: Loading and off loading. 154.1730... Operating Requirements § 154.1730 Ethylene oxide: Loading and off loading. (a) The master shall ensure that before ethylene oxide is loaded into a cargo tank: (1) The tank is thoroughly clean, dry, and free of...

  8. Long-term rate orientations: Development plan 1993

    International Nuclear Information System (INIS)

    1992-01-01

    Hydro-Quebec's preferred rate orientations for Quebec markets are presented. The background for a rate structure revision is outlined, followed by proposed changes to residential and general rates, and by a plan to implement the new rate structure. Some of the principles used in setting rates are described. The new rate structure proposals are intended to provide a better reflection of the utility's costs of supply and a clearer signal in favor of the rational use of electricity, thereby limiting long-term increases in both supply costs and electricity rates. It is proposed to use marginal costs to design rate structures, while the overall rate level will continue to reflect changes in average costs of supply. Also included in the proposed changes are time-of-use rates, which will help reduce costs by shifting loads from peak to off-peak periods and by encouraging the adoption of energy-conservation measures. Moreover, the integration of time-of-use options into the rate system will not only provide Hydro-Quebec with more powerful load-management tools but also give customers the opportunity to change their consumption patterns and thereby reduce their electricity bills. 11 figs., 11 tabs

  9. Optimal Topology of Aircraft Rib and Spar Structures under Aeroelastic Loads

    Science.gov (United States)

    Stanford, Bret K.; Dunning, Peter D.

    2014-01-01

    Several topology optimization problems are conducted within the ribs and spars of a wing box. It is desired to locate the best position of lightening holes, truss/cross-bracing, etc. A variety of aeroelastic metrics are isolated for each of these problems: elastic wing compliance under trim loads and taxi loads, stress distribution, and crushing loads. Aileron effectiveness under a constant roll rate is considered, as are dynamic metrics: natural vibration frequency and flutter. This approach helps uncover the relationship between topology and aeroelasticity in subsonic transport wings, and can therefore aid in understanding the complex aircraft design process which must eventually consider all these metrics and load cases simultaneously.

  10. Peak load-impulse characterization of critical pulse loads in structural dynamics

    International Nuclear Information System (INIS)

    Abrahamson, G.R.; Lindberg, H.E.

    1975-01-01

    In presenting the characterization scheme, some general features are described first. A detailed analysis is given for the rigid-plastic system of one degree of freedom to illustrate the calculation of critical load curves in terms of peak load and impulse. This is followed by the presentation of critical load curves for uniformly loaded rigid-plastic beams and plates and for dynamic buckling of cylindrical shells under uniform lateral loads. The peak load-impulse characterization of critical pulse loads is compared with the dynamic load factor characterization, and some aspects of the history of the peak load-pulse scheme are presented. (orig./HP) [de

  11. Investigation of load leveling in Hokuriku Electric Power Co., Inc.; Hokuriku denryoku no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    Hokuriku Electric Power Co., Inc. aims at an around 2% improvement of the load factor up to 2005, by which the quick and proper service and the proposal of load leveling menu are planned. This paper describes an outline of the investigation of load leveling. Various programs have been proposed so that the customers can further shift the load by their consideration. Proposed systems include the time-of-day electricity rate system, the load regulation contract system for industries, the seasonal time-of-day rate system, the electric power system for snowmelt in which the load is dumped at the peak, and the secondary electric power system for snowmelt. Accompanying with the revision of electric utility law, the enlargement of its available time, the price reduction, and the discount rate system for the ice regenerative air conditioners have been provided. For the business activities, a demonstration model house was exhibited to indicate a proper house with local characteristics in Hokuriku district. Furthermore, the spreading activities of regenerative systems and the consulting activities have been positively promoted. 4 figs., 1 tab.

  12. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    Science.gov (United States)

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  13. Optimized Control Strategy For Over Loaded Offshore Wind Turbines

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Knudsen, Torben; Wisniewski, Rafal

    2015-01-01

    controller tuning for a given wind turbine. It also enables a very safe and robust comparison between a new control strategy and the present one. Main body of abstract Is it true that power de-rating indeed the best way to reduce loads? The power de-rating approach has the drawback of only indirectly...

  14. Investigation of Redistribution of Pile Foundation Forces Under Successive Loading of Its Elements

    Science.gov (United States)

    Sedin, Vladimir; Bikus, Kateryna; Kovba, Vladislav

    2017-12-01

    Redistribution of pile foundation forces under successive loading of its elements was investigated under laboratory conditions. A segment of pile foundation model was taken for use in the case study. Load tests on the pile foundation model segment, without joining its elements (pile and plate, which turns into grillage) and based on different combinations of static loadings were conducted. This proved that the loading of a plate causes skin friction on some length of the pile side surface as well as providing additional loading and settlement. Test results have shown that application of successive elements enables the foundation to carry loads up to 13% higher than in the case of a standard pile foundation loading with the same settlement rates.

  15. Dental responsibility loadings and the relative value of dental services.

    Science.gov (United States)

    Teusner, D N; Ju, X; Brennan, D S

    2017-09-01

    To estimate responsibility loadings for a comprehensive list of dental services, providing a standardized unit of clinical work effort. Dentists (n = 2500) randomly sampled from the Australian Dental Association membership (2011) were randomly assigned to one of 25 panels. Panels were surveyed by questionnaires eliciting responsibility loadings for eight common dental services (core items) and approximately 12 other items unique to that questionnaire. In total, loadings were elicited for 299 items listed in the Australian Dental Schedule 9th Edition. Data were weighted to reflect the age and sex distribution of the workforce. To assess reliability, regression models assessed differences in core item loadings by panel assignment. Estimated loadings were described by reporting the median and mean. Response rate was 37%. Panel composition did not vary by practitioner characteristics. Core item loadings did not vary by panel assignment. Oral surgery and endodontic service areas had the highest proportion (91%) of services with median loadings ≥1.5, followed by prosthodontics (78%), periodontics (76%), orthodontics (63%), restorative (62%) and diagnostic services (31%). Preventive services had median loadings ≤1.25. Dental responsibility loadings estimated by this study can be applied in the development of relative value scales. © 2017 Australian Dental Association.

  16. The analytical description of high temperature tensile creep for cavitating materials subjected to time variable loads

    International Nuclear Information System (INIS)

    Bocek, M.

    A phenomenological cavitation model is presented by means of which the life time as well as the creep curve equations can be calculated for cavitating materials subjected to time variable tensile loads. The model precludes the proportionality between the damage A and the damage rate (dA/dt) resp. Both are connected by the life time function tau. The latter is derived from static stress rupture tests and contains the loading conditions. From this model the life fraction rule (LFR) is derived. The model is used to calculate the creep curves of cavitating materials subjected at high temperatures to non-stationary tensile loading conditions. In the present paper the following loading procedures are considered: creep at constant load F and true stress s; creep at linear load increase ((dF/dt)=const) and creep at constant load amplitude cycling (CLAC). For these loading procedures the creep equations for cavitating and non-cavitating specimens are derived. Under comparable conditions the creep rate of cavitating materials are higher than for non-cavitating ones. (author)

  17. STRESS LOADING SIMULATION OF HYDRO-MECHANICAL TRANSMISSION OF DUMP TRUCK

    Directory of Open Access Journals (Sweden)

    S. A. Sidorov

    2006-01-01

    Full Text Available The Transmission model and software package to investigate stress loading of a hydromechanical transmission of a dump truck have been developed. The given software package allows to model stress loading of transmission gears in taking-off and acceleration modes at various road resistance, positions of an engine control pedal and initial revolutions of an engine crankshaft, various laws of friction clutch switching and some other parameters that permit to reveal a rate of various operational mode influence on stress loading of a dump truck transmission. An equivalence of the developed software is proved by the comparison of the experimentally obtained stress loading process of the hydro-mechanical transmission of a BelAZ- 7555 dump truck with the results of the simulation 

  18. System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

    2014-12-23

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

  19. Monitoring external and internal loads of brazilian soccer referees during official matches.

    Science.gov (United States)

    Costa, Eduardo C; Vieira, Caio M A; Moreira, Alexandre; Ugrinowitsch, Carlos; Castagna, Carlo; Aoki, Marcelo S

    2013-01-01

    This study aimed to assess the external and internal loads of Brazilian soccer referees during official matches. A total of 11 field referees (aged 36.2 ± 7.5 years) were monitored during 35 matches. The external (distance covered, mean and maximal speed) and internal load parameters (session ratings of perceived exertion [RPE] training load [TL], Edwards' TL, and time spent in different heart rate [HR] zones) were assessed in 3-4 matches per referee. External load parameters were measured using a wrist Global Positioning System (GPS) receiver. No differences in distance covered (5.219 ± 205 vs. 5.230 ± 237 m) and maximal speed (19.3 ± 1.0 vs. 19.4 ± 1.4 km·h(-1)) were observed between the halves of the matches (p > 0.05). However, the mean speed was higher in the first half of the matches (6.6 ± 0.4 vs. 6.4 ± 0.3 km·h(-1)) (p external and internal load demands during official matches. The portable GPS/HR monitors and session RPE method can provide relevant information regarding the magnitude of the physiological strain during official matches. Key PointsHigh external and internal loads were imposed on Brazilian soccer referees during official matches.There was a high positive correlation between a subjective marker of internal load (session RPE) and parameters of external load (distance covered between 90-100% of HRmax and maximal speed).There was a high positive correlation between session RPE method and Edwards' method.Session RPE seems to be a reliable marker of internal load.The portable GPS/HR monitors and the session RPE method can provide relevant information regarding the magnitude of external and internal loads of soccer referees during official matches.

  20. The characterization of secondary lithium-ion battery degradation when operating complex, ultra-high power pulsed loads

    Science.gov (United States)

    Wong, Derek N.

    The US Navy is actively developing all electric fleets, raising serious questions about what is required of onboard power supplies in order to properly power the ship's electrical systems. This is especially relevant when choosing a viable power source to drive high power propulsion and electric weapon systems in addition to the conventional loads deployed aboard these types of vessels. Especially when high pulsed power loads are supplied, the issue of maintaining power quality becomes important and increasingly complex. Conventionally, a vessel's electrical power is generated using gas turbine or diesel driven motor-generator sets that are very inefficient when they are used outside of their most efficient load condition. What this means is that if the generator is not being utilized continuously at its most efficient load capacity, the quality of the output power may also be effected and fall outside of the acceptable power quality limits imposed through military standards. As a solution to this potential problem, the Navy has proposed using electrochemical storage devices since they are able to buffer conventional generators when the load is operating below the generator's most efficient power level or able to efficiently augment a generator when the load is operating in excess of the generator's most efficient power rating. Specifically, the US Navy is interested in using commercial off-the-shelf (COTS) lithium-ion batteries within an intelligently controlled energy storage module that could act as either a prime power supply for on-board pulsed power systems or as a backup generator to other shipboard power systems. Due to the unique load profile of high-rate pulsed power systems, the implementation of lithium-ion batteries within these complex systems requires them to be operated at very high rates and the effects these things have on cell degradation has been an area of focus. There is very little published research into the effects that high power transient

  1. Startup analysis for a high temperature gas loaded heat pipe

    Science.gov (United States)

    Sockol, P. M.

    1973-01-01

    A model for the rapid startup of a high-temperature gas-loaded heat pipe is presented. A two-dimensional diffusion analysis is used to determine the rate of energy transport by the vapor between the hot and cold zones of the pipe. The vapor transport rate is then incorporated in a simple thermal model of the startup of a radiation-cooled heat pipe. Numerical results for an argon-lithium system show that radial diffusion to the cold wall can produce large vapor flow rates during a rapid startup. The results also show that startup is not initiated until the vapor pressure p sub v in the hot zone reaches a precise value proportional to the initial gas pressure p sub i. Through proper choice of p sub i, startup can be delayed until p sub v is large enough to support a heat-transfer rate sufficient to overcome a thermal load on the heat pipe.

  2. Enhancing transformer dynamic rating through grid application of photovoltaic arrays

    International Nuclear Information System (INIS)

    El-Gasseir, M.M.; Sayer, M.A.; Alteneder, K.P.; McCulla, G.A.; Bigger, J.

    1993-01-01

    This paper demonstrates that exact matching between the substation's peak-day load profile and the profile of coincident net output generation of the PV array is unjustifiable and will unduly lead to overlooking many investment deferment opportunities that would otherwise be major components of high value applications of PV arrays. Further, the paper shows how and to what extent the load matchability requirement could be relaxed. Because of the thermal inertia of transformers, the output of an adequately sized and located photovoltaic array can both delay and reduce transformer temperature rise even in cases where load peak occurs after sunset. The time lag due to thermal inertia and ambient temperature decline allow overloading of the transformer beyond its normal rating without significant loss of life. Simulations depicting the interplay between PV array capacity, ambient temperature, transformer size, oil and winding temperature rise, peak load magnitude, load profile and loss of life, have been conducted. Tradeoffs between PV array capacity and transformer over-rating gains have been assessed. The impacts of PV generation on the over-rating potential of an actual 22.4-MVA bank transformer of a Salt River Project (SRP) distribution substation in Phoenix, Arizona were evaluated

  3. System and method employing a self-organizing map load feature database to identify electric load types of different electric loads

    Science.gov (United States)

    Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

    2014-06-17

    A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

  4. Design of a Load-Balancing Architecture For Parallel Firewalls

    National Research Council Canada - National Science Library

    Joyner, William

    1999-01-01

    Because firewalls can become a potential choke point as network speeds and loads increase, the Navy needs a cost-effective means of increasing data rate through firewalls by placing several machines...

  5. Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.

    Science.gov (United States)

    Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-06-01

    Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is

  6. Experimental Study on Mechanical and Acoustic Emission Characteristics of Rock-Like Material Under Non-uniformly Distributed Loads

    Science.gov (United States)

    Wang, Xiao; Wen, Zhijie; Jiang, Yujing; Huang, Hao

    2018-03-01

    The mechanical and acoustic emission characteristics of rock-like materials under non-uniform loads were investigated by means of a self-developed mining-induced stress testing system and acoustic emission monitoring system. In the experiments, the specimens were divided into three regions and different initial vertical stresses and stress loading rates were used to simulate different mining conditions. The mechanical and acoustic emission characteristics between regions were compared, and the effects of different initial vertical stresses and different stress loading rates were analysed. The results showed that the mechanical properties and acoustic emission characteristics of rock-like materials can be notably localized. When the initial vertical stress and stress loading rate are fixed, the peak strength of region B is approximately two times that of region A, and the maximum acoustic emission hit value of region A is approximately 1-2 times that of region B. The effects of the initial vertical stress and stress loading rate on the peck strain, maximum hit value, and occurrence time of the maximum hit are similar in that when either of the former increase, the latter all decrease. However, peck strength will increase with the increase in loading rate and decrease with the increase in initial vertical stress. The acoustic emission hits can be used to analyse the damage in rock material, but the number of acoustic emission hits cannot be used alone to determine the degree of rock damage directly.

  7. An Attempt to Shorten Loading Time of Epirubicin into DC Beads{sup ®} Using Vibration and a Sieve

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, Akinaga, E-mail: akinagasonoda@yahoo.co.jp; Nitta, Norihisa [Shiga University of Medical Science, Department of Radiology (Japan); Yamamoto, Takefumi [Shiga University of Medical Science, Central Research Laboratory (Japan); Tomozawa, Yuki; Ohta, Shinichi; Watanabe, Shobu; Murata, Kiyoshi [Shiga University of Medical Science, Department of Radiology (Japan)

    2017-04-15

    PurposeWe investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads{sup ®}) to be used for transarterial chemoembolization.MethodAfter separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.ResultsSpectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.DiscussionThe use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.

  8. Demand Response Load Following of Source and Load Systems

    DEFF Research Database (Denmark)

    Hu, Jianqiang; Cao, Jinde; Yong, Taiyou

    2017-01-01

    This paper presents a demand response load following strategy for an interconnected source and load system, in which we utilize traditional units and population of cooling thermostatically controlled loads (TCLs) to follow the mismatched power caused by the load activities and the renewable power...... injection in real time. In the demand side of power systems, these TCLs are often affiliated to a bus load agent and can be aggregated to multiple TCL aggregators. Firstly, aggregate evaluation of the TCL aggregator is carried out based on a bilinear aggregate model so as to derive the available regulation...

  9. Cognitive Load Theory: How Many Types of Load Does It Really Need?

    Science.gov (United States)

    Kalyuga, Slava

    2011-01-01

    Cognitive load theory has been traditionally described as involving three separate and additive types of load. Germane load is considered as a learning-relevant load complementing extraneous and intrinsic load. This article argues that, in its traditional treatment, germane load is essentially indistinguishable from intrinsic load, and therefore…

  10. Terbinafine-loaded wound dressing for chronic superficial fungal infections

    International Nuclear Information System (INIS)

    Paskiabi, Farnoush Asghari; Bonakdar, Shahin; Shokrgozar, Mohammad Ali; Imani, Mohammad; Jahanshiri, Zahra; Shams-Ghahfarokhi, Masoomeh; Razzaghi-Abyaneh, Mehdi

    2017-01-01

    In spite of developing new drugs and modern formulations, the treatments of chronic fungal infections are still challenging. Fibrous wound dressings are new suggestions for the treatment of chronic superficial infections. In the present study, we formulated an antifungal agent, terbinafine hydrochloride (TFH), which is a hydrophobic drug, in wound dressings prepared by electrospun polycaprolactone, polycaprolactone/gelatin (50:50 w/w) and gelatin. To obtain more water-stable meshes, the preparations were treated by glutaraldehyde and their properties were determined before and after treatment. The morphology of fibrous meshes was observed by scanning electron microscopy. Drug loading efficiency and release rate were measured by high performance liquid chromatography (HPLC) and the release rate was monitored for 144 h. Antifungal tests were performed on Trichophyton mentagrophytes, Aspergillus fumigatus and Candida albicans cultured on Muller-Hinton agar. The toxicity of the meshes was measured after 24 h and 14 days by MTT assay. Terbinafine loading of polycaprolactone/gelatin (50:50) was 100% and it released the highest amount of TFH too. In antifungal tests, all samples were able to hinderT. mentagrophytes and A. fumigatus but not C. albicans growth among them, polycaprolactone fibers made the largest inhibition zone. In MTT assay, none of prepared samples showed toxicity against L929 cells. Teken together, the prepared TFH-loaded PCL/gelatin electrospun meshes were able to release TFH slowly and in a steady state in time. With respect to no obvious cytotoxicity in MTT assay and stong antifungal activity toward T. mentagrophytesin vitro, these TFH-based meshes could be considered as potential candidates in clinical application as wound dressing for treatment of chronic dermatophytosis. - Highlights: • Terbinafine (TFH)-loaded PCL/gelatin electrospun fibers were successfully fabricated. • TFH-loaded PCL/gelatin electrospun fibers showed a slow drug release

  11. Terbinafine-loaded wound dressing for chronic superficial fungal infections

    Energy Technology Data Exchange (ETDEWEB)

    Paskiabi, Farnoush Asghari [Department of Mycology, Pasteur Institute of Iran, Tehran 13164. Iran (Iran, Islamic Republic of); Microbiology Research Center, Pasteur Institute of Iran, Tehran 13164. Iran (Iran, Islamic Republic of); Bonakdar, Shahin; Shokrgozar, Mohammad Ali [National Cell Bank Department, Pasteur Institute of Iran, Tehran 13164 (Iran, Islamic Republic of); Imani, Mohammad [Department of Novel Drug Delivery Systems, Iran Polymer and Petrochemical Institute, Tehran (Iran, Islamic Republic of); Jahanshiri, Zahra [Department of Mycology, Pasteur Institute of Iran, Tehran 13164. Iran (Iran, Islamic Republic of); Shams-Ghahfarokhi, Masoomeh [Department of Mycology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Razzaghi-Abyaneh, Mehdi, E-mail: mrab442@yahoo.com [Department of Mycology, Pasteur Institute of Iran, Tehran 13164. Iran (Iran, Islamic Republic of); Microbiology Research Center, Pasteur Institute of Iran, Tehran 13164. Iran (Iran, Islamic Republic of)

    2017-04-01

    In spite of developing new drugs and modern formulations, the treatments of chronic fungal infections are still challenging. Fibrous wound dressings are new suggestions for the treatment of chronic superficial infections. In the present study, we formulated an antifungal agent, terbinafine hydrochloride (TFH), which is a hydrophobic drug, in wound dressings prepared by electrospun polycaprolactone, polycaprolactone/gelatin (50:50 w/w) and gelatin. To obtain more water-stable meshes, the preparations were treated by glutaraldehyde and their properties were determined before and after treatment. The morphology of fibrous meshes was observed by scanning electron microscopy. Drug loading efficiency and release rate were measured by high performance liquid chromatography (HPLC) and the release rate was monitored for 144 h. Antifungal tests were performed on Trichophyton mentagrophytes, Aspergillus fumigatus and Candida albicans cultured on Muller-Hinton agar. The toxicity of the meshes was measured after 24 h and 14 days by MTT assay. Terbinafine loading of polycaprolactone/gelatin (50:50) was 100% and it released the highest amount of TFH too. In antifungal tests, all samples were able to hinderT. mentagrophytes and A. fumigatus but not C. albicans growth among them, polycaprolactone fibers made the largest inhibition zone. In MTT assay, none of prepared samples showed toxicity against L929 cells. Teken together, the prepared TFH-loaded PCL/gelatin electrospun meshes were able to release TFH slowly and in a steady state in time. With respect to no obvious cytotoxicity in MTT assay and stong antifungal activity toward T. mentagrophytesin vitro, these TFH-based meshes could be considered as potential candidates in clinical application as wound dressing for treatment of chronic dermatophytosis. - Highlights: • Terbinafine (TFH)-loaded PCL/gelatin electrospun fibers were successfully fabricated. • TFH-loaded PCL/gelatin electrospun fibers showed a slow drug release

  12. DC switching regulated power supply for driving an inductive load

    Science.gov (United States)

    Dyer, George R.

    1986-01-01

    A power supply for driving an inductive load current from a dc power supply hrough a regulator circuit including a bridge arrangement of diodes and switching transistors controlled by a servo controller which regulates switching in response to the load current to maintain a selected load current. First and second opposite legs of the bridge are formed by first and second parallel-connected transistor arrays, respectively, while the third and fourth legs of the bridge are formed by appropriately connected first and second parallel connected diode arrays, respectively. The regulator may be operated in three "stages" or modes: (1) For current runup in the load, both first and second transistor switch arrays are turned "on" and current is supplied to the load through both transistor arrays. (2) When load current reaches the desired level, the first switch is turned "off", and load current "flywheels" through the second switch array and the fourth leg diode array connecting the second switch array in series with the load. Current is maintained by alternating between modes 1 and 2 at a suitable duty cycle and switching rate set by the controller. (3) Rapid current rundown is accomplished by turning both switch arrays "off", allowing load current to be dumped back into the source through the third and fourth diode arrays connecting the source in series opposition with the load to recover energy from the inductive load. The three operating states are controlled automatically by the controller.

  13. Performance of a cognitive load inventory during simulated handoffs: Evidence for validity.

    Science.gov (United States)

    Young, John Q; Boscardin, Christy K; van Dijk, Savannah M; Abdullah, Ruqayyah; Irby, David M; Sewell, Justin L; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-01-01

    Advancing patient safety during handoffs remains a public health priority. The application of cognitive load theory offers promise, but is currently limited by the inability to measure cognitive load types. To develop and collect validity evidence for a revised self-report inventory that measures cognitive load types during a handoff. Based on prior published work, input from experts in cognitive load theory and handoffs, and a think-aloud exercise with residents, a revised Cognitive Load Inventory for Handoffs was developed. The Cognitive Load Inventory for Handoffs has items for intrinsic, extraneous, and germane load. Students who were second- and sixth-year students recruited from a Dutch medical school participated in four simulated handoffs (two simple and two complex cases). At the end of each handoff, study participants completed the Cognitive Load Inventory for Handoffs, Paas' Cognitive Load Scale, and one global rating item for intrinsic load, extraneous load, and germane load, respectively. Factor and correlational analyses were performed to collect evidence for validity. Confirmatory factor analysis yielded a single factor that combined intrinsic and germane loads. The extraneous load items performed poorly and were removed from the model. The score from the combined intrinsic and germane load items associated, as predicted by cognitive load theory, with a commonly used measure of overall cognitive load (Pearson's r = 0.83, p load during handoffs may be measured via a self-report measure. Additional work is required to develop an adequate measure of extraneous load.

  14. Load management for refrigeration systems: Potentials and barriers

    Energy Technology Data Exchange (ETDEWEB)

    Grein, Arne, E-mail: a.grein@tu-berlin.de [University of Technology Berlin, Institute for Energy Technology, Department of Energy Systems, Einsteinufer 25 (TA8), 10587 Berlin (Germany); Pehnt, Martin [Institute for Energy and Environmental Research Heidelberg (ifeu), Wilckensstr. 3, 69120 Heidelberg (Germany)

    2011-09-15

    As a strategy to deal with the increasing intermittent input of renewable energy sources in Germany, the adaptation of power consumption is complementary to power-plant regulation, grid expansion and physical energy storage. One demand sector that promises strong returns for load management efforts is cooling and refrigeration. In these processes, thermal inertia provides a temporal buffer for shifting and adjusting the power consumption of cooling systems. We have conducted an empirical investigation to obtain a detailed and time-resolved bottom-up analysis of load management for refrigeration systems in the city of Mannheim, Germany. We have extrapolated our results to general conditions in Germany. Several barriers inhibit the rapid adoption of load management strategies for cooling systems, including informational barriers, strict compliance with legal cooling requirements, liability issues, lack of technical experience, an inadequate rate of return and organizational barriers. Small commercial applications of refrigeration in the food-retailing and cold storage in hotels and restaurants are particularly promising starting points for intelligent load management. When our results are applied to Germany, suitable sectors for load management have theoretical and achievable potential values of 4.2 and 2.8 GW, respectively, amounting to about 4-6% of the maximum power demand in Germany. - Highlights: > Potential and barriers for implementation of load shifting for refrigeration. > Empirical investigation for time-resolved bottom-up analysis in Mannheim, Germany. > Suitable sectors and further recommendations for introducing load management.> Extrapolation of results from local to national level.

  15. Load management for refrigeration systems: Potentials and barriers

    International Nuclear Information System (INIS)

    Grein, Arne; Pehnt, Martin

    2011-01-01

    As a strategy to deal with the increasing intermittent input of renewable energy sources in Germany, the adaptation of power consumption is complementary to power-plant regulation, grid expansion and physical energy storage. One demand sector that promises strong returns for load management efforts is cooling and refrigeration. In these processes, thermal inertia provides a temporal buffer for shifting and adjusting the power consumption of cooling systems. We have conducted an empirical investigation to obtain a detailed and time-resolved bottom-up analysis of load management for refrigeration systems in the city of Mannheim, Germany. We have extrapolated our results to general conditions in Germany. Several barriers inhibit the rapid adoption of load management strategies for cooling systems, including informational barriers, strict compliance with legal cooling requirements, liability issues, lack of technical experience, an inadequate rate of return and organizational barriers. Small commercial applications of refrigeration in the food-retailing and cold storage in hotels and restaurants are particularly promising starting points for intelligent load management. When our results are applied to Germany, suitable sectors for load management have theoretical and achievable potential values of 4.2 and 2.8 GW, respectively, amounting to about 4-6% of the maximum power demand in Germany. - Highlights: → Potential and barriers for implementation of load shifting for refrigeration. → Empirical investigation for time-resolved bottom-up analysis in Mannheim, Germany. → Suitable sectors and further recommendations for introducing load management.→ Extrapolation of results from local to national level.

  16. Influence of sampling frequency and load calculation methods on quantification of annual river nutrient and suspended solids loads.

    Science.gov (United States)

    Elwan, Ahmed; Singh, Ranvir; Patterson, Maree; Roygard, Jon; Horne, Dave; Clothier, Brent; Jones, Geoffrey

    2018-01-11

    Better management of water quality in streams, rivers and lakes requires precise and accurate estimates of different contaminant loads. We assessed four sampling frequencies (2 days, weekly, fortnightly and monthly) and five load calculation methods (global mean (GM), rating curve (RC), ratio estimator (RE), flow-stratified (FS) and flow-weighted (FW)) to quantify loads of nitrate-nitrogen (NO 3 - -N), soluble inorganic nitrogen (SIN), total nitrogen (TN), dissolved reactive phosphorus (DRP), total phosphorus (TP) and total suspended solids (TSS), in the Manawatu River, New Zealand. The estimated annual river loads were compared to the reference 'true' loads, calculated using daily measurements of flow and water quality from May 2010 to April 2011, to quantify bias (i.e. accuracy) and root mean square error 'RMSE' (i.e. accuracy and precision). The GM method resulted into relatively higher RMSE values and a consistent negative bias (i.e. underestimation) in estimates of annual river loads across all sampling frequencies. The RC method resulted in the lowest RMSE for TN, TP and TSS at monthly sampling frequency. Yet, RC highly overestimated the loads for parameters that showed dilution effect such as NO 3 - -N and SIN. The FW and RE methods gave similar results, and there was no essential improvement in using RE over FW. In general, FW and RE performed better than FS in terms of bias, but FS performed slightly better than FW and RE in terms of RMSE for most of the water quality parameters (DRP, TP, TN and TSS) using a monthly sampling frequency. We found no significant decrease in RMSE values for estimates of NO 3 - N, SIN, TN and DRP loads when the sampling frequency was increased from monthly to fortnightly. The bias and RMSE values in estimates of TP and TSS loads (estimated by FW, RE and FS), however, showed a significant decrease in the case of weekly or 2-day sampling. This suggests potential for a higher sampling frequency during flow peaks for more precise

  17. Walking economy is predictably determined by speed, grade, and gravitational load.

    Science.gov (United States)

    Ludlow, Lindsay W; Weyand, Peter G

    2017-11-01

    The metabolic energy that human walking requires can vary by more than 10-fold, depending on the speed, surface gradient, and load carried. Although the mechanical factors determining economy are generally considered to be numerous and complex, we tested a minimum mechanics hypothesis that only three variables are needed for broad, accurate prediction: speed, surface grade, and total gravitational load. We first measured steady-state rates of oxygen uptake in 20 healthy adult subjects during unloaded treadmill trials from 0.4 to 1.6 m/s on six gradients: -6, -3, 0, 3, 6, and 9°. Next, we tested a second set of 20 subjects under three torso-loading conditions (no-load, +18, and +31% body weight) at speeds from 0.6 to 1.4 m/s on the same six gradients. Metabolic rates spanned a 14-fold range from supine rest to the greatest single-trial walking mean (3.1 ± 0.1 to 43.3 ± 0.5 ml O 2 ·kg -body -1 ·min -1 , respectively). As theorized, the walking portion (V̇o 2-walk  =  V̇o 2-gross - V̇o 2-supine-rest ) of the body's gross metabolic rate increased in direct proportion to load and largely in accordance with support force requirements across both speed and grade. Consequently, a single minimum-mechanics equation was derived from the data of 10 unloaded-condition subjects to predict the pooled mass-specific economy (V̇o 2-gross , ml O 2 ·kg -body + load -1 ·min -1 ) of all the remaining loaded and unloaded trials combined ( n = 1,412 trials from 90 speed/grade/load conditions). The accuracy of prediction achieved ( r 2  = 0.99, SEE = 1.06 ml O 2 ·kg -1 ·min -1 ) leads us to conclude that human walking economy is predictably determined by the minimum mechanical requirements present across a broad range of conditions. NEW & NOTEWORTHY Introduced is a "minimum mechanics" model that predicts human walking economy across a broad range of conditions from only three variables: speed, surface grade, and body-plus-load mass. The derivation

  18. Influence of pain and gender on impact loading during walking: A randomised trial

    DEFF Research Database (Denmark)

    Henriksen, M.; Christensen, R.; Alkjaer, T.

    2008-01-01

    measured using force platforms and accelerometers attached to the tibia and sacrum. Impact ground reaction force peaks and loading rates, and peak accelerations were used to quantify impact loadings. Attenuation was quantified by means of a transfer function between the tibial and sacral accelerometer...

  19. Motor unit recruitment and firing rate in medial gastrocnemius muscles during external perturbations in standing in humans.

    Science.gov (United States)

    Pollock, C L; Ivanova, T D; Hunt, M A; Garland, S J

    2014-10-01

    There is limited investigation of the interaction between motor unit recruitment and rate coding for modulating force during standing or responding to external perturbations. Fifty-seven motor units were recorded from the medial gastrocnemius muscle with intramuscular electrodes in response to external perturbations in standing. Anteriorly directed perturbations were generated by applying loads in 0.45-kg increments at the pelvis every 25-40 s until 2.25 kg was maintained. Motor unit firing rate was calculated for the initial recruitment load and all subsequent loads during two epochs: 1) dynamic response to perturbation directly following each load drop and 2) maintenance of steady state between perturbations. Joint kinematics and surface electromyography (EMG) from lower extremities and force platform measurements were assessed. Application of the external loads resulted in a significant forward progression of the anterior-posterior center of pressure (AP COP) that was accompanied by modest changes in joint angles (recruitment, motor unit firing rate immediately after the load drop was significantly lower than during subsequent load drops or during the steady state at the same load. There was a modest increase in motor unit firing rate immediately after the load drop on subsequent load drops associated with regaining balance. There was no effect of maintaining balance with increased load and forward progression of the AP COP on steady-state motor unit firing rate. The medial gastrocnemius utilized primarily motor unit recruitment to achieve the increased levels of activation necessary to maintain standing in the presence of external loads. Copyright © 2014 the American Physiological Society.

  20. PowerChoice Residential Customer Response to TOU Rates

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Jane S.; Moezzi, Mithra; Lutzenhiser, Susan; Woods, James; Dethman, Linda; Kunkle, Rick

    2009-10-01

    Research Into Action, Inc. and the Sacramento Municipal Utility District (SMUD) worked together to conduct research on the behaviors and energy use patterns of SMUD residential customers who voluntarily signed on to a Time-of-Use rate pilot launched under the PowerChoice label. The project was designed to consider the how and why of residential customers ability and willingness to engage in demand reduction behaviors, and to link social and behavioral factors to observed changes in demand. The research drew on a combination of load interval data and three successive surveys of participating households. Two experimental treatments were applied to test the effects of increased information on households ability to respond to the Time-of-Use rates. Survey results indicated that participants understood the purpose of the Time-of-Use rate and undertook substantial appropriate actions to shift load and conserve. Statistical tests revealed minor initial price effects and more marked, but still modest, adjustments to seasonal rate changes. Tests of the two information interventions indicated that neither made much difference to consumption patterns. Despite the lackluster statistical evidence for load shifting, the analysis points to key issues for critical analysis and development of residential Time-of-Use rates, especially pertinent as California sets the stage for demand response in more California residences.

  1. Dynamical load factor of impact loaded shell structures

    International Nuclear Information System (INIS)

    Hammel, J.

    1977-01-01

    Dynamical loaded structures can be analysed by spectral representations, which usually lead to an enormous computational effort. If it is possible to find a fitting dynamical load factor, the dynamical problem can be reduced to a statical one. The computation of this statical problem is much simpler. The disadvantage is that the dynamical load factor usually leads to a very rough approximation. In this paper it will be shown, that by combination of these two methods, the approximation of the dynamical load factor can be improved and the consumption of computation time can be enormously reduced. (Auth.)

  2. Pilot power based rate control in CDMA 2000 1x EV-DO Rev-A

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-feng; GU Jian; YANG Hong-wen

    2008-01-01

    This article proposes a new algorithm to improvethe rate control efficiency of enhanced reverse link mediumaccess control (RLMAC) in the code division multiple access(CDMA) lx EV-DO release A(Rev. A) system. The newalgorithm brings reverse access terminal (AT) pilot power tothe RLMAC rate control procedure and makes it easier for alow pilot power user to increase its data rate when the systemis slightly loaded and harder to decrease its date rate when thesystem is heavily loaded. Numerical results of system levelsimulations show that the new algorithm can bring highersystem throughput, lower AT transmission power, and lowersystem load.

  3. Wavelet neural network load frequency controller

    International Nuclear Information System (INIS)

    Hemeida, Ashraf Mohamed

    2005-01-01

    This paper presents the feasibility of applying a wavelet neural network (WNN) approach for the load frequency controller (LFC) to damp the frequency oscillations of two area power systems due to load disturbances. The present intelligent control system trained the wavelet neural network (WNN) controller on line with adaptive learning rates, which are derived in the sense of a discrete type Lyapunov stability theorem. The present WNN controller is designed individually for each area. The proposed technique is applied successfully for a wide range of operating conditions. The time simulation results indicate its superiority and effectiveness over the conventional approach. The effects of consideration of the governor dead zone on the system performance are studied using the proposed controller and the conventional one

  4. Research of Impact Load in Large Electrohydraulic Load Simulator

    Directory of Open Access Journals (Sweden)

    Yongguang Liu

    2014-01-01

    Full Text Available The stronger impact load will appear in the initial phase when the large electric cylinder is tested in the hardware-in-loop simulation. In this paper, the mathematical model is built based on AMESim, and then the reason of the impact load is investigated through analyzing the changing tendency of parameters in the simulation results. The inhibition methods of impact load are presented according to the structural invariability principle and applied to the actual system. The final experimental result indicates that the impact load is inhibited, which provides a good experimental condition for the electric cylinder and promotes the study of large load simulator.

  5. Preliminary Assessment McGhee - Tyson ANGB, McGhee - Tyson Municipal Airport, Knoxville, Tennessee

    Science.gov (United States)

    1988-06-01

    shales and siltstones are 700.2000 .0 brown, brownish gray, medium to dark gray. lossililerous. calcareous: limestones are argillaceous to pure , gray...shale. PUMPKIN Shale and siltstone, reddish-brown to qsoyish-red. gteenish~gtary and 100-750 VALLEY SHALE oliv*egray: with thin sandstones. limestones...Rogersville shale Wrt..............Cambrian Rutledge limestone Ipv ..............Cambrian Pumpkin Valley ................... Cambrian Rome Figure 111.2

  6. Association between anxiety and depression symptoms with resistant hypertension and central hemodynamics: A pilot study.

    LENUS (Irish Health Repository)

    Mermerelis, A

    2016-01-01

    The hypothesis that symptoms of anxiety and depression contribute to the development of hypertension has been controversial. Rutledge and Hogan found that the risk of developing hypertension is approximately 8% higher among people with psychological distress compared to those with minimal distress. People suffering from either severe depression or anxiety were two to three times more likely to develop hypertension.\\r\

  7. Fitness-related differences in the rate of whole-body total heat loss in exercising young healthy women are heat-load dependent.

    Science.gov (United States)

    Lamarche, Dallon T; Notley, Sean R; Poirier, Martin P; Kenny, Glen P

    2018-03-01

    What is the central question of this study? Aerobic fitness modulates heat loss, albeit the heat load at which fitness-related differences occur in young healthy women remains unclear. What is the main finding and its importance? We demonstrate using direct calorimetry that fitness modulates heat loss in a heat-load dependent manner, with differences occurring between young women of low and high fitness and matched physical characteristics when the metabolic heat load is at least 400 W in hot, dry conditions. Although fitness has been known for some time to modulate heat loss, our findings define the metabolic heat load at which fitness-related differences occur. Aerobic fitness has recently been shown to alter heat loss capacity in a heat-load dependent manner in young men. However, given that sex-related differences in heat loss capacity exist, it is unclear whether this response is consistent in women. We therefore assessed whole-body total heat loss in young (21 ± 3 years old) healthy women matched for physical characteristics, but with low (low-fit; 35.8 ± 4.5 ml O 2  kg -1  min -1 ) or high aerobic fitness (high-fit; 53.1 ± 5.1 ml O 2  kg -1  min -1 ; both n = 8; indexed by peak oxygen consumption), during three 30 min bouts of cycling performed at increasing rates of metabolic heat production of 250 (Ex1), 325 (Ex2) and 400 W (Ex3), each separated by a 15 min recovery, in hot, dry conditions (40°C, 11% relative humidity). Whole-body total heat loss (evaporative ± dry heat exchange) and metabolic heat production were measured using direct and indirect calorimetry, respectively. Body heat content was measured as the temporal summation of heat production and loss. Total heat loss did not differ during Ex1 (low-fit, 215 ± 16 W; high-fit, 231 ± 20 W; P > 0.05) and Ex2 (low-fit, 278 ± 15 W; high-fit, 301 ± 20 W; P > 0.05), but was lower in the low-fit (316 ± 21 W) compared with the high-fit women (359 ± 32

  8. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  9. Apparent Dependence of Rate- and State-Dependent Friction Parameters on Loading Velocity and Cumulative Displacement Inferred from Large-Scale Biaxial Friction Experiments

    Science.gov (United States)

    Urata, Yumi; Yamashita, Futoshi; Fukuyama, Eiichi; Noda, Hiroyuki; Mizoguchi, Kazuo

    2017-06-01

    We investigated the constitutive parameters in the rate- and state-dependent friction (RSF) law by conducting numerical simulations, using the friction data from large-scale biaxial rock friction experiments for Indian metagabbro. The sliding surface area was 1.5 m long and 0.5 m wide, slid for 400 s under a normal stress of 1.33 MPa at a loading velocity of either 0.1 or 1.0 mm/s. During the experiments, many stick-slips were observed and those features were as follows. (1) The friction drop and recurrence time of the stick-slip events increased with cumulative slip displacement in an experiment before which the gouges on the surface were removed, but they became almost constant throughout an experiment conducted after several experiments without gouge removal. (2) The friction drop was larger and the recurrence time was shorter in the experiments with faster loading velocity. We applied a one-degree-of-freedom spring-slider model with mass to estimate the RSF parameters by fitting the stick-slip intervals and slip-weakening curves measured based on spring force and acceleration of the specimens. We developed an efficient algorithm for the numerical time integration, and we conducted forward modeling for evolution parameters ( b) and the state-evolution distances (L_{{c}}), keeping the direct effect parameter ( a) constant. We then identified the confident range of b and L_{{c}} values. Comparison between the results of the experiments and our simulations suggests that both b and L_{{c}} increase as the cumulative slip displacement increases, and b increases and L_{{c}} decreases as the loading velocity increases. Conventional RSF laws could not explain the large-scale friction data, and more complex state evolution laws are needed.

  10. Response to severe changes of load on the reactor system of nuclear ship Mutsu

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Ochiai, Masa-aki; Tanaka, Yoshimi; Yao, Toshiaki; Inoue, Kimio.

    1993-01-01

    The response of the nuclear power system of N.S. Mutsu to severe changes of load have been studied from records taken during the power-raising tests performed on the ship in 1990. The records examined were those involving the most severe load changes foreseen for marine reactors: (a) sharp load increase with total steam flow raised from 25 to 70 % rated full flow in 13s, (b) crash astern maneuver with the position of propulsion turbine command handle changed-taking several seconds-from cruising ahead to STOP, and after about 50s, further changed-taking 30s-to bring the astern propulsion turbine to full speed-to consume approximately 60 % rated total steam flow and (c) turbine trip with the ahead turbine intentionally tripped when operating at roughly 100 % rated total steam flow. The foregoing records from load changes-of severity beyond what is foreseen for land-based reactors-proved that the Mutsu reactor is capable of responding smoothly and securely to such severe load changes. These load changes occasioned relatively large mismatches between reactor power supply and steam flow demand, but with notable freedom from any conspicuous overshooting or hunting of the reactor power. This performance can be attributed to (a) correct functioning of the automatic power control system, (b) effective contribution of the self-regulating reactor control property deriving from the large negative feedback between moderator temperature and reactivity, and (c) the ample inventories of coolant in the primary and secondary loops. The responses to load change are discussed covering those relevant to (a) reactor power, (b) primary loop pressure, and (c) steam generator pressure, with particular reference to the differences seen in response to mild and to severe load changes. (author)

  11. Effects of loading rate and temperature on anaerobic co-digestion of food waste and waste activated sludge in a high frequency feeding system, looking in particular at stability and efficiency.

    Science.gov (United States)

    Li, Qian; Li, Hao; Wang, Gaojun; Wang, Xiaochang

    2017-08-01

    A continuously stirred tank reactor (CSTR) with a high feeding frequency (HFF) of once every 15min was employed in order to ease the loading shock frequently occurred in digester with a low feeding frequency. The effects of the organic loading rate (OLR) and temperature on the co-digestion of food waste and waste activated sludge was evaluated in a 302-day long-term experiment. Due to the high hydrolysis rate, the maximum CH 4 yield in a thermophilic reactor was 407mL CH 4 /gVS added , a value that was significantly higher than the 350mL CH 4 /gVS added that occurred in a mesophilic reactor. Although the alkalinity declined when HRT was shorted than 10d, caused by the decrease of conversion ratio from protein to ammonium, the increase of specific methanogenic activity helped HFF system to achieve stable performance at an OLR of 11.2 (HRT 7.5d) and 30.2gVS/L/d (HRT 3d) under mesophilic and thermophilic conditions, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Sustainable organic loading rate and energy recovery potential of mesophilic anaerobic membrane bioreactor for municipal wastewater treatment

    KAUST Repository

    Wei, Chunhai

    2014-08-01

    The overall performance of a mesophilic anaerobic membrane bioreactor (AnMBR) for synthetic municipal wastewater treatment was investigated under a range of organic loading rate (OLR). A very steady and high chemical oxygen demand (COD) removal (around 98%) was achieved over a broad range of volumetric OLR of 0.8-10gCOD/L/d. The sustainable volumetric and sludge OLR satisfying a permeate COD below 50mg/L for general reuse was 6gCOD/L/d and 0.63gCOD/gMLVSS (mixed liquor volatile suspended solids)/d, respectively. At a high sludge OLR of over 0.6gCOD/gMLVSS/d, the AnMBR achieved high methane production of over 300ml/gCOD (even approaching the theoretical value of 382ml/gCOD). A low biomass production of 0.015-0.026gMLVSS/gCOD and a sustainable flux of 6L/m2/h were observed. The integration of a heat pump and forward osmosis into the mesophilic AnMBR process would be a promising way for net energy recovery from typical municipal wastewater in a temperate area. © 2014 Elsevier Ltd.

  13. Sustainable organic loading rate and energy recovery potential of mesophilic anaerobic membrane bioreactor for municipal wastewater treatment

    KAUST Repository

    Wei, Chunhai; Harb, Moustapha; Amy, Gary L.; Hong, Pei-Ying; Leiknes, TorOve

    2014-01-01

    The overall performance of a mesophilic anaerobic membrane bioreactor (AnMBR) for synthetic municipal wastewater treatment was investigated under a range of organic loading rate (OLR). A very steady and high chemical oxygen demand (COD) removal (around 98%) was achieved over a broad range of volumetric OLR of 0.8-10gCOD/L/d. The sustainable volumetric and sludge OLR satisfying a permeate COD below 50mg/L for general reuse was 6gCOD/L/d and 0.63gCOD/gMLVSS (mixed liquor volatile suspended solids)/d, respectively. At a high sludge OLR of over 0.6gCOD/gMLVSS/d, the AnMBR achieved high methane production of over 300ml/gCOD (even approaching the theoretical value of 382ml/gCOD). A low biomass production of 0.015-0.026gMLVSS/gCOD and a sustainable flux of 6L/m2/h were observed. The integration of a heat pump and forward osmosis into the mesophilic AnMBR process would be a promising way for net energy recovery from typical municipal wastewater in a temperate area. © 2014 Elsevier Ltd.

  14. Cyclic strength of metals at impact strain rates

    International Nuclear Information System (INIS)

    Eleiche, A.M.; El-Kady, M.M.

    1987-01-01

    Rigorous understanding of the effects of impact loading on the mechanical response of materials and structures is essential for the optimum design and safe operation of many sophisticated engineering systems and components, such as industrial high-energy-rate fabrication processes and nuclear reactor containments. Extensive data are available at present on the dynamic behaviour of most metals in uniaxial tension, compression, torsion and pure shear, when they are subjected to diversified loading conditions, ranging from those characterised by monotonic constant rates, to those involving forward or reverse strain-rate jumps of several orders of magnitude. What appears to be missing in the current material data banks, however, is detailed information concerning the mechanical response under cyclic loading at impact strain rates. Such data are needed for engineering design purposes on one hand, and for the formulation of proper constitutive equations and the accurate modeling of deformation processes on the other. In the present paper, typical stress-strain characteristics at ambient temperature for copper, mild steel and titanium are first exhibited. The application of the unified Bodner-Partom constitutive theory to these data is then presented and discussed. (orig./GL)

  15. Effect of ripple loads on sustained-load cracking in titanium alloys

    International Nuclear Information System (INIS)

    Pao, P.S.; Meyn, D.A.; Bayles, R.A.; Feng, C.R.; Yoder, G.R.

    1995-01-01

    In the present paper, the authors have extended their study on the effect of the ripple loads on the sustained-load cracking (SLC) behavior of two titanium alloys, Ti-6Al-4V (an α-β alloy) and Ti-15V-3Cr-3Al-3Sn (a β-α alloy), in an ambient air environment. The methodology which has been used successfully to treat ripple effects on stress-corrosion cracking (SCC) is employed again to address the influence of ripple loads on sustained-load cracking. Ripple loads can significantly reduce the apparent sustained load cracking resistance of titanium alloys in a relatively benign environment such as ambient air. For a ripple-load amplitude equal to 5% of the sustained load, the ripple-load cracking thresholds (K IRLC ) of beta-annealed Ti-6Al-4V and Ti-15V-3Cr-3al-3Sn are less than half of the respective sustained-load cracking thresholds (K ISLC ). The extent of ripple-load degradation for these alloys in ambient air -- relative to K ISLC , were found comparable to those observed in a much more aggressive 3.5% NaCl aqueous solution

  16. Strain rate effect on fault slip and rupture evolution: Insight from meter-scale rock friction experiments

    Science.gov (United States)

    Xu, Shiqing; Fukuyama, Eiichi; Yamashita, Futoshi; Mizoguchi, Kazuo; Takizawa, Shigeru; Kawakata, Hironori

    2018-05-01

    We conduct meter-scale rock friction experiments to study strain rate effect on fault slip and rupture evolution. Two rock samples made of Indian metagabbro, with a nominal contact dimension of 1.5 m long and 0.1 m wide, are juxtaposed and loaded in a direct shear configuration to simulate the fault motion. A series of experimental tests, under constant loading rates ranging from 0.01 mm/s to 1 mm/s and under a fixed normal stress of 6.7 MPa, are performed to simulate conditions with changing strain rates. Load cells and displacement transducers are utilized to examine the macroscopic fault behavior, while high-density arrays of strain gauges close to the fault are used to investigate the local fault behavior. The observations show that the macroscopic peak strength, strength drop, and the rate of strength drop can increase with increasing loading rate. At the local scale, the observations reveal that slow loading rates favor generation of characteristic ruptures that always nucleate in the form of slow slip at about the same location. In contrast, fast loading rates can promote very abrupt rupture nucleation and along-strike scatter of hypocenter locations. At a given propagation distance, rupture speed tends to increase with increasing loading rate. We propose that a strain-rate-dependent fault fragmentation process can enhance the efficiency of fault healing during the stick period, which together with healing time controls the recovery of fault strength. In addition, a strain-rate-dependent weakening mechanism can be activated during the slip period, which together with strain energy selects the modes of fault slip and rupture propagation. The results help to understand the spectrum of fault slip and rock deformation modes in nature, and emphasize the role of heterogeneity in tuning fault behavior under different strain rates.

  17. Experience with high percent step load decrease from full power in NPP Krsko

    International Nuclear Information System (INIS)

    Vukovic, V.

    2000-01-01

    The control system of NPP Kriko, is designed to automatically control the reactor in the power range between 15 and 100 percent of rated power for the following designed transients; - 10 percent step change in load; 5 percent per minute loading and unloading; step full load decrease with the aid of automatically initiated and controlled steam dump. Because station operation below 15 percent of rated power is designed for a period of time during startup or standby conditions, automatic control below 15 percent is not provided. The steam dump accomplishes the following functional tasks: it permits the nuclear plants to accept a sudden 95 percent loss of load without incurring reactor trip; it removes stored energy and residual heat following a reactor trip and brings the plant to equilibrium no-load conditions without actuation of the steam generator safety valves; it permits control of the steam generator pressure at no-load conditions and permits a manually controlled cooldown of the plant. The first two functional tasks are controlled by Tavg. The third is controlled by steam pressure. Interlocks minimise any possibility of an inadvertent actuation of steam dump system. This paper discusses relationships between designed (described) characteristics of plant and the data which are obtained during startup and/or first ten years of operation. (author)

  18. Cognitive load, emotion, and performance in high-fidelity simulation among beginning nursing students: a pilot study.

    Science.gov (United States)

    Schlairet, Maura C; Schlairet, Timothy James; Sauls, Denise H; Bellflowers, Lois

    2015-03-01

    Establishing the impact of the high-fidelity simulation environment on student performance, as well as identifying factors that could predict learning, would refine simulation outcome expectations among educators. The purpose of this quasi-experimental pilot study was to explore the impact of simulation on emotion and cognitive load among beginning nursing students. Forty baccalaureate nursing students participated in teaching simulations, rated their emotional state and cognitive load, and completed evaluation simulations. Two principal components of emotion were identified representing the pleasant activation and pleasant deactivation components of affect. Mean rating of cognitive load following simulation was high. Linear regression identiffed slight but statistically nonsignificant positive associations between principal components of emotion and cognitive load. Logistic regression identified a negative but statistically nonsignificant effect of cognitive load on assessment performance. Among lower ability students, a more pronounced effect of cognitive load on assessment performance was observed; this also was statistically non-significant. Copyright 2015, SLACK Incorporated.

  19. Transiently Loaded Bucket Foundations in Saturated Dense Sand - Demonstration of the Boot Effect

    DEFF Research Database (Denmark)

    Nielsen, Søren Dam; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    2017-01-01

    The mono bucket foundation is a cost-effective foundation for offshore wind turbines. During a storm, these foundations are exposed to large wave loads of short duration. This paper investigates the effect of increased loading rate on the bearing capacity of two mono bucket foundations installed ...

  20. Influence of organic loading rate on methane production in a CSTR from physicochemical sludge generated in a poultry slaughterhouse.

    Science.gov (United States)

    López-Escobar, Luis A; Martínez-Hernández, Sergio; Corte-Cano, Grisel; Méndez-Contreras, Juan M

    2014-01-01

    The influence of the increase of the organic loading rate (OLR) on methane production in a continuous stirred-tank reactor (CSTR) from physicochemical sludge generated in a poultry slaughterhouse was evaluated. Total solid (TS) to obtain OLR of 1, 5, 10 and 15 g VS L(-1) day(-1), with hydraulic retention times of 29, 6, 6 and 4, respectively, were conditioned. The results showed a decrease in pH levels and an increase in the theoretical volatile fatty acids (VFA). While the yield of methane production decreased from 0.48 to 0.10 LCH4/g VSremoved, respectively, the OLR-10 managed on average 38% removal of volatile solids (VS) and a yield biogas production of 0.81 Lbiogas g(-1) VSremoved and 1.35 L day(-1). This suggests that the OLR increases in an anaerobic system from physicochemical sludge only inhibits the methanogenic metabolism, because there is still substrate consumption and biogas production.

  1. Low cognitive load strengthens distractor interference while high load attenuates when cognitive load and distractor possess similar visual characteristics.

    Science.gov (United States)

    Minamoto, Takehiro; Shipstead, Zach; Osaka, Naoyuki; Engle, Randall W

    2015-07-01

    Studies on visual cognitive load have reported inconsistent effects of distractor interference when distractors have visual characteristic that are similar to the cognitive load. Some studies have shown that the cognitive load enhances distractor interference, while others reported an attenuating effect. We attribute these inconsistencies to the amount of cognitive load that a person is required to maintain. Lower amounts of cognitive load increase distractor interference by orienting attention toward visually similar distractors. Higher amounts of cognitive load attenuate distractor interference by depleting attentional resources needed to process distractors. In the present study, cognitive load consisted of faces (Experiments 1-3) or scenes (Experiment 2). Participants performed a selective attention task in which they ignored face distractors while judging a color of a target dot presented nearby, under differing amounts of load. Across these experiments distractor interference was greater in the low-load condition and smaller in the high-load condition when the content of the cognitive load had similar visual characteristic to the distractors. We also found that when a series of judgments needed to be made, the effect was apparent for the first trial but not for the second. We further tested an involvement of working memory capacity (WMC) in the load effect (Experiment 3). Interestingly, both high and low WMC groups received an equivalent effect of the cognitive load in the first distractor, suggesting these effects are fairly automatic.

  2. Ductile Crack Initiation Criterion with Mismatched Weld Joints Under Dynamic Loading Conditions.

    Science.gov (United States)

    An, Gyubaek; Jeong, Se-Min; Park, Jeongung

    2018-03-01

    Brittle failure of high toughness steel structures tends to occur after ductile crack initiation/propagation. Damages to steel structures were reported in the Hanshin Great Earthquake. Several brittle failures were observed in beam-to-column connection zones with geometrical discontinuity. It is widely known that triaxial stresses accelerate the ductile fracture of steels. The study examined the effects of geometrical heterogeneity and strength mismatches (both of which elevate plastic constraints due to heterogeneous plastic straining) and loading rate on critical conditions initiating ductile fracture. This involved applying the two-parameter criterion (involving equivalent plastic strain and stress triaxiality) to estimate ductile cracking for strength mismatched specimens under static and dynamic tensile loading conditions. Ductile crack initiation testing was conducted under static and dynamic loading conditions using circumferentially notched specimens (Charpy type) with/without strength mismatches. The results indicated that the condition for ductile crack initiation using the two parameter criterion was a transferable criterion to evaluate ductile crack initiation independent of the existence of strength mismatches and loading rates.

  3. Bit Loading Algorithms for Cooperative OFDM Systems

    Directory of Open Access Journals (Sweden)

    Gui Bo

    2008-01-01

    Full Text Available Abstract We investigate the resource allocation problem for an OFDM cooperative network with a single source-destination pair and multiple relays. Assuming knowledge of the instantaneous channel gains for all links in the entire network, we propose several bit and power allocation schemes aiming at minimizing the total transmission power under a target rate constraint. First, an optimal and efficient bit loading algorithm is proposed when the relay node uses the same subchannel to relay the information transmitted by the source node. To further improve the performance gain, subchannel permutation, in which the subchannels are reallocated at relay nodes, is considered. An optimal subchannel permutation algorithm is first proposed and then an efficient suboptimal algorithm is considered to achieve a better complexity-performance tradeoff. A distributed bit loading algorithm is also proposed for ad hoc networks. Simulation results show that significant performance gains can be achieved by the proposed bit loading algorithms, especially when subchannel permutation is employed.

  4. Bit Loading Algorithms for Cooperative OFDM Systems

    Directory of Open Access Journals (Sweden)

    Bo Gui

    2007-12-01

    Full Text Available We investigate the resource allocation problem for an OFDM cooperative network with a single source-destination pair and multiple relays. Assuming knowledge of the instantaneous channel gains for all links in the entire network, we propose several bit and power allocation schemes aiming at minimizing the total transmission power under a target rate constraint. First, an optimal and efficient bit loading algorithm is proposed when the relay node uses the same subchannel to relay the information transmitted by the source node. To further improve the performance gain, subchannel permutation, in which the subchannels are reallocated at relay nodes, is considered. An optimal subchannel permutation algorithm is first proposed and then an efficient suboptimal algorithm is considered to achieve a better complexity-performance tradeoff. A distributed bit loading algorithm is also proposed for ad hoc networks. Simulation results show that significant performance gains can be achieved by the proposed bit loading algorithms, especially when subchannel permutation is employed.

  5. The effects of combining dynamic pricing, AC load control, and real-time energy feedback. SMUD'S 2011 Residential Summer Solutions Study

    Energy Technology Data Exchange (ETDEWEB)

    Herter, K. [Herter Energy Research Solutions, El Dorado Hills, CA (United States); Wood, V. [Sacramento Municipal Utility District, Sacramento, CA (United States); Blozis, S. [University of California, Davis, CA (United States)

    2013-11-15

    The 2011 Residential Summer Solutions Study compared the hourly load effects of three different real-time information treatments and two program options. The information treatments included: Baseline information (no real-time data), real-time Home information (whole-house data), and real-time Appliance information (data for the whole house plus three individual appliances). Compared to the Baseline group, real-time Home information lowered overall energy use by about 4 %. Real-time information at both the Home and Appliance levels had a significant effect on non-event peak loads: compared to the Baseline group, real-time Home data lowered peak load by 5 %, while Appliance data lowered peak load by 7 %. All three information treatments averaged a 1-kW (40 %) load shed during events. The customer-chosen program options included a dynamic time-of-use rate and a load control incentive program. Customers were more likely to sign up for the dynamic rate, and those who did saved significantly more peak load on both event days (>50 % savings) and non-event days (>20 % savings) than did those on the load control program alone. In addition, those on the dynamic rate saved twice as much on their summer bills as did those who chose to remain on the standard tiered rate. At the end of the summer, more than 90 % of participants signed up to participate again the following year.

  6. Optimal loading and protection of multi-state systems considering performance sharing mechanism

    International Nuclear Information System (INIS)

    Xiao, Hui; Shi, Daimin; Ding, Yi; Peng, Rui

    2016-01-01

    Engineering systems are designed to carry the load. The performance of the system largely depends on how much load it carries. On the other hand, the failure rate of the system is strongly affected by its load. Besides internal failures, such as fatigue and aging process, systems may also fail due to external impacts such as nature disasters and terrorism. In this paper, we integrate the effect of loading and protection of external impacts on multi-state systems with performance sharing mechanism. The objective of this research is to determine how to balance the load and protection on system elements. An availability evaluation algorithm of the proposed system is suggested and the corresponding optimization problem is solved utilizing genetic algorithms. - Highlights: • Performance sharing of multi-state systems is considered. • The effect of load on system elements is analyzed. • Joint optimization model of element loading and protection is formulated. • Genetic Algorithms are adapted to solve the reliability optimization problem.

  7. Monitoring of Failure Mechanisms in a Composite Bending Actuator during Cyclic Loading by Acoustic Emission

    Science.gov (United States)

    Woo, Sung-Choong; Goo, Nam Seo

    The objective of this work is to investigate the influence of electromechanical cyclic loading on the performance of a bending piezoelectric composite actuator. We have analyzed the fatigue damage mechanisms in terms of the behavior of the AE event rate. It was found that whether the actuators are subjected to purely electric loading or electromechanical loading, the initial fatigue damage of the bending piezoelectric composite actuator was caused by the transgranular fracture in the PZT ceramic layer; the final failure was caused only in the case of PCAWB under electromechanical loading by a local discharge, which critically affected the performance reduction of the actuators. As the number of cycles increased, a large reduction in displacement performance coincided with a high AE event rate, which was identified via microscopic observations.

  8. Factor Analysis of the Aggregated Electric Vehicle Load Based on Data Mining

    Directory of Open Access Journals (Sweden)

    Yao Wang

    2012-06-01

    Full Text Available Electric vehicles (EVs and the related infrastructure are being developed rapidly. In order to evaluate the impact of factors on the aggregated EV load and to coordinate charging, a model is established to capture the relationship between the charging load and important factors based on data mining. The factors can be categorized as internal and external. The internal factors include the EV battery size, charging rate at different places, penetration of the charging infrastructure, and charging habits. The external factor is the time-of-use pricing (TOU policy. As a massive input data is necessary for data mining, an algorithm is implemented to generate a massive sample as input data which considers real-world travel patterns based on a historical travel dataset. With the input data, linear regression was used to build a linear model whose inputs were the internal factors. The impact of the internal factors on the EV load can be quantified by analyzing the sign, value, and temporal distribution of the model coefficients. The results showed that when no TOU policy is implemented, the rate of charging at home and range anxiety exerts the greatest influence on EV load. For the external factor, a support vector regression technique was used to build a relationship between the TOU policy and EV load. Then, an optimization model based on the relationship was proposed to devise a TOU policy that levels the load. The results suggest that implementing a TOU policy reduces the difference between the peak and valley loads remarkably.

  9. Distribution load estimation (DLE)

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A; Lehtonen, M [VTT Energy, Espoo (Finland)

    1998-08-01

    The load research has produced customer class load models to convert the customers` annual energy consumption to hourly load values. The reliability of load models applied from a nation-wide sample is limited in any specific network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to find improvements to the load models or, in general, improvements to the load estimates. In Distribution Load Estimation (DLE) the measurements from the network are utilized to improve the customer class load models. The results of DLE will be new load models that better correspond to the loading of the distribution network but are still close to the original load models obtained by load research. The principal data flow of DLE is presented

  10. Phloem loading--not metaphysical, only complex: towards a unified model of phloem loading.

    Science.gov (United States)

    Komor, E; Orlich, G; Weig, A; Köckenberger, W

    1996-08-01

    level in most organs of the seedling and throughout the germination period. Leaves of adult Ricinus have significantly lower levels of this transcript. Recirculation of excess, phloem-delivered solutes from the sink back to the source is shown not only to be a common feature of long-distance transport, but the only way that an imbalance between supply to and consumption of nutrients in the sink can be adjusted in the source. It is a pathway by which sink activity regulates phloem loading. Non-invasive NMR imaging revealed the flow rates and flow speeds in phloem and xylem in the intact seedling and proved directly the existence of an internal circulating solution flow. A unified model of phloem loading is proposed, based on a pump-and-leak model, where active sucrose carriers (and other carriers) accumulate solutes in the sieve tubes with a concomitant build-up of pressure resulting in mass flow. Plasmodesmata are leaks (as are the transport carriers, too), slowing down the transport rate, but they also serve as diffusion channels for substances which are produced in the neighbouring cell. Therefore, compounds, which are not made in the sieve tubes themselves are translocated together with the bulk solution of sieve tube sap.

  11. Residential Load Manageability Factor Analyses by Load Sensitivity Affected by Temperature

    Directory of Open Access Journals (Sweden)

    N. Eskandari

    2016-12-01

    Full Text Available Load side management is the basic and significant principle to keeping the balance between generation side and consumption side of electrical power energy. Load side management on typical medium voltage feeder is the power energy consumption control of connected loads with variation of essential parameters that loads do reaction to their variation. Knowing amount of load's reaction to each parameters variation in typical medium voltage feeder during the day, leads to gain Load Manageability Factor (LMF for that specific feeder that helps power utilities to manage their connected loads. Calculating this LMF needs to find out each types of load with unique inherent features behavior to each parameters variation. This paper results and future work results will help us to catch mentioned LMF. In this paper analysis of residential load behavior due to temperature variation with training artificial neural network will be done. Load behavior due to other essential parameters variations like energy pricing variation, major event happening, and power utility announcing to the customers, and etc will study in future works. Collecting all related works results in a unit mathematical equation or an artificial neural network will gain LMF.

  12. Opposite Effects of Capacity Load and Resolution Load on Distractor Processing

    OpenAIRE

    Zhang, Weiwei; Luck, Steven J.

    2014-01-01

    According to the load theory of attention, an increased perceptual load reduces distractor processing whereas an increased working memory load facilitates distractor processing. Here we raise the possibility that the critical distinction may instead be between an emphasis on resolution and an emphasis on capacity. That is, perceptual load manipulations typically emphasize resolution (fine-grained discriminations), whereas working memory load manipulations typically emphasize capacity (simulta...

  13. Pay for load demand - electricity pricing with load demand component

    International Nuclear Information System (INIS)

    Pyrko, Jurek; Sernhed, Kerstin; Abaravicius, Juozas

    2003-01-01

    This publication is part of a project called Direct and Indirect Load Control in Buildings. Peak load problems have attracted considerable attention in Sweden during last three winters, caused by a significant decrease in available reserve power, which is a consequence of political decisions and liberalisation of the electricity market. A possible way to lower peak loads, avoiding electricity shortages and reducing electricity costs both for users and utilities, is to make customers experience the price difference during peak load periods and, in this way, become more aware of their energy consumption pattern and load demand. As of January 1st 2001, one of the Swedish energy utilities - Sollentuna Energi - operating in the Stockholm area, introduced a new electricity tariff with differentiated grid fees based on a mean value of the peak load every month. This tariff was introduced for all residential customers in the service area. The objective of this study is to investigate the extent to which a Load Demand Component, included in electricity pricing, can influence energy use and load demand in residential buildings. What are the benefits and disadvantages for customers and utilities? This paper investigates the impact of the new tariff on the utility and different types of typical residential customers, making comparisons with previous tariff. Keywords Load demand, electricity pricing, tariff, residential customers, energy behaviour

  14. Deformation response of Zr after shock-loading

    International Nuclear Information System (INIS)

    Song, S.G.; Gray, G.T. III, and; Lopez, M.F.

    1996-01-01

    The post-shock stress-strain response and microstructural evolution of Zr shock-loaded to 7 GPa were investigated. A Bauschinger effect in the room temperature reload stress-strain behavior due to shock-loading has been observed following yielding. Deformation twinning is shown to play a more important role than slip during post-shock plastic deformation and work hardening. The work hardening rate of the shock-prestrained specimens is less temperature sensitive than that of annealed Zr. The underlying microstructures responsible for the Bauschinger effect and the differences in work hardening behavior are characterized. A new type of dense dislocation arrangement occurring during the shock-wave deformation of Zr is discussed. copyright 1996 American Institute of Physics

  15. Characterization of Celecoxib-Loaded Solid Lipid Nanoparticles ...

    African Journals Online (AJOL)

    system with several advantages, including enhanced physical stability, dual loading ability for lipophilic and .... where kp is the release rate constant at the elapsed time t, n is a constant, where the value of n ≤ 0.45 indicates .... CXB and the hydrocarbon chain of the esterified fatty acids in the lipids. Upon emulsification CXB.

  16. Methods for monitoring the initial load to critical in the fast test reactor

    International Nuclear Information System (INIS)

    Johnson, D.L.

    1975-08-01

    Conventional symmetric fuel loadings for the initial loading to critical of the Fast Test Reactor (FTR) are predicted to be more time consuming than asymmetric or trisector loadings. Potentially significant time savings can be realized by the latter, since adequate intermediate assessments of neutron multiplication can be made periodically without control rod reconnection in all trisectors. Experimental simulation of both loading schemes was carried out in the Reverse Approach to Critical (RAC) experiments in the Fast Test Reactor-Engineering Mockup Critical facility. Analyses of these experiments indicated that conventional source multiplication methods can be applied for monitoring either a symmetric or asymmetric fuel loading scheme equally well provided that detection efficiency corrections are employed. Methods for refining predictions of reactivity and count rates for the stages in a load to critical were also investigated. (auth)

  17. STRESS LOADING SIMULATION OF HYDRO-MECHANICAL TRANSMISSION OF DUMP TRUCK

    OpenAIRE

    S. A. Sidorov

    2006-01-01

    The Transmission model and software package to investigate stress loading of a hydromechanical transmission of a dump truck have been developed. The given software package allows to model stress loading of transmission gears in taking-off and acceleration modes at various road resistance, positions of an engine control pedal and initial revolutions of an engine crankshaft, various laws of friction clutch switching and some other parameters that permit to reveal a rate of various operational m...

  18. Fracture behavior of nuclear graphites under tensile impact loading

    International Nuclear Information System (INIS)

    Ugachi, Hirokazu; Ishiyama, Shintaro; Eto, Motokuni

    1994-01-01

    Impact tensile strength test was performed with two kinds of HTTR graphites, fine grained isotropic graphite, IG-11 and coarse grained near isotropic graphite, PGX and deformation and fracture behavior under the strain rate of over 100s -1 was measured and the following results were derived: (1) Tensile strength for IG-11 graphite does not depend on the strain rate less than 1 s -1 , but over 1 s -1 , tensile strength for IG-11 graphite increase larger than that measured under 1 s -1 . At the strain rate more than 100 s -1 , remarkable decrease of tensile strength for IG-11 graphite was found. Tensile strength of PGX graphite does not depend on the strain rate less than 1 s -1 , but beyond this value, the sharp tensile strength decrease occurs. (2) Under 100 s -1 , fracture strain for both graphites increase with increase of strain rate and over 100 s -1 , drastic increase of fracture strain for IG-11 graphite was found. (3) At the part of gage length, volume of specimen increase with increase of tensile loading level and strain rate. (4) Poisson's ratio for both graphites decrease with increase of tensile loading level and strain rate. (5) Remarkable change of stress-strain curve for both graphites under 100 s -1 was not found, but over 100 s -1 , the slope of these curve for IG-11 graphite decrease drastically. (author)

  19. Cardiorespiratory parameters in draught horses before and after short term draught work pulling loads.

    Science.gov (United States)

    Pérez, R; Recabarren, S E; Mora, G; Jara, C; Quijada, G; Hetz, E

    1992-04-01

    In order to establish the relationship between draught force and cardiorespiratory responses to exercise heart rate (HR), respiratory rate (RR), arterial and venous blood gases, pH, hemoglobin concentration and temperature were measured in five draught horses during rest, immediately after exercise and 30 min post-exercise under field conditions. A wagon equipped with an odometer and a hydraulic dynamometer was used for measuring distance and draught force. The wagon was loaded with 946 kg for the low load, 1,979 kg for the medium load and 2,994 kg for the high load, and drawn for a distance of 1,500 m. Draught force and load weight were linearly related. The response of the draught horse to low and medium load exercise was characterized by a moderate increase in HR, RR and temperature with no significant changes in arterial blood gases and pH. An increase in HR, RR and temperature was observed, whereas no changes in arterial PO2 and increases in venous PO2 were noticed after high load exercise. Slight increase in venous lactic acid concentration as a result of high load exercise was observed, suggesting that some anaerobic work was performed. However this was insufficient to produce changes in blood pH. The increase in metabolic requirements during the three levels of draught exercise was associated with increases in arterial hemoglobin concentration and oxygen content of blood.

  20. Fracture Energy of Plain Concrete Beams at Different Rates of Loading

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Hansen, Lars Pilegaard; Madsen, S. H.

    . The beams are tested in a closed loop servo controlled materials testing system. The experimental results for these preliminary tests show that the bending tensile strength is increasing with the displacement rate and that the fracture energy is constant at lower displacement rates and then increasing...

  1. Study of Pneumatic Servo Loading System in Double-Sided Polishing

    International Nuclear Information System (INIS)

    Qian, N; Ruan, J; Li, W

    2006-01-01

    The precise double-sided polishing process is one of the main methods to get the ultra-smooth surface of workpiece. In double-sided polishing machine, a loading system is required to be able to precisely control the load superimposed on the workpiece, while the polishing is being carried out. A pneumatic servo loading system is proposed for this purpose. In the pneumatic servo system, the servo valve, which acts both the electrical to mechanical converter and the power amplifier, has a substantial influence on the performance of the loading system. Therefore a specially designed pneumatic digital servo valve is applied in the control system. In this paper, the construction of the pneumatic servo loading system in double-sided polishing machine and control strategy associated with the digital servo valve are first addressed. The mathematical model of the system established and the hardware of the pneumatic servo system is designed. Finally, the experiments are carried out by measuring the practical load on the workpiece and the quality of the surface finish. It is demonstrated that the error rate of load is less than 5% and a super-smooth surface of silicon wafer with roughness Ra 0.401 nm can be obtained

  2. Responses of apple fruit size to tree water status and crop load.

    Science.gov (United States)

    Naor, A; Naschitz, S; Peres, M; Gal, Y

    2008-08-01

    The combined effects of irrigation rate and crop load on apple yield and fruit size were examined in two commercial apple orchards (cv. Golden Delicious) in a semi-arid zone. The irrigation rates applied were 1, 3 and 7 mm day(-1), and the two fruit thinning treatments involved adjusting crop load to 100 and 300 fruits per tree at Ortal and 50 and 150 fruits per tree at Matityahu. Unthinned trees served as the control. The fruit from each tree was picked separately, and fruit size distribution was determined with a commercial grading machine. Midday stem water potentials varied from -0.9 to -2.8 MPa, crop load varied from 80,000 to 1,900,000 fruit ha(-1) and crop yield varied from 10 to 144 Mg ha(-1). Midday stem water potential decreased with increasing crop load in all irrigation treatments at Matityahu, but only in the 1 mm day(-1) treatment at Ortal. The extent of the lowering of midday stem water potential by crop load decreased with increasing soil water availability. At both orchards, a similar response of total crop yield to crop load on a per hectare basis was observed. Mean fruit mass and relative yield of fruit > 70 mm in diameter increased with midday stem water potential, with the low crop loads having similar but steeper slopes than the high crop load. The responses of mean fruit mass and relative yield of fruit > 70 mm in diameter to midday stem water potential were similar at both orchards, perhaps indicating that thresholds for irrigation scheduling are transferable to other orchards within a region. Factors that may limit the transferability of these thresholds are discussed.

  3. High burn rate solid composite propellants

    Science.gov (United States)

    Manship, Timothy D.

    High burn rate propellants help maintain high levels of thrust without requiring complex, high surface area grain geometries. Utilizing high burn rate propellants allows for simplified grain geometries that not only make production of the grains easier, but the simplified grains tend to have better mechanical strength, which is important in missiles undergoing high-g accelerations. Additionally, high burn rate propellants allow for a higher volumetric loading which reduces the overall missile's size and weight. The purpose of this study is to present methods of achieving a high burn rate propellant and to develop a composite propellant formulation that burns at 1.5 inches per second at 1000 psia. In this study, several means of achieving a high burn rate propellant were presented. In addition, several candidate approaches were evaluated using the Kepner-Tregoe method with hydroxyl terminated polybutadiene (HTPB)-based propellants using burn rate modifiers and dicyclopentadiene (DCPD)-based propellants being selected for further evaluation. Propellants with varying levels of nano-aluminum, nano-iron oxide, FeBTA, and overall solids loading were produced using the HTPB binder and evaluated in order to determine the effect the various ingredients have on the burn rate and to find a formulation that provides the burn rate desired. Experiments were conducted to compare the burn rates of propellants using the binders HTPB and DCPD. The DCPD formulation matched that of the baseline HTPB mix. Finally, GAP-plasticized DCPD gumstock dogbones were attempted to be made for mechanical evaluation. Results from the study show that nano-additives have a substantial effect on propellant burn rate with nano-iron oxide having the largest influence. Of the formulations tested, the highest burn rate was a 84% solids loading mix using nano-aluminum nano-iron oxide, and ammonium perchlorate in a 3:1(20 micron: 200 micron) ratio which achieved a burn rate of 1.2 inches per second at 1000

  4. Giant, Voltage-Actuated Deformation of a Dielectric Elastomer under Dead Load

    OpenAIRE

    Huang, Jiangshui; Li, Tiefeng; Foo, Choon Chiang; Clarke, David R.; Zhu, Jian; Suo, Zhigang

    2012-01-01

    Far greater voltage-actuated deformation is achievable for a dielectric elastomer under equal-biaxial dead load than under rigid constraint usually employed. Areal strains of 488% are demonstrated. The dead load suppresses electric breakdown, enabling the elastomer to survive the snap-through electromechanical instability. The breakdown voltage is found to increase with the voltage ramp rate. A nonlinear model for viscoelastic dielectric elastomers is developed and shown to be consistent with...

  5. Dynamic fracture initiation in brittle materials under combined mode I/II loading

    International Nuclear Information System (INIS)

    Nakano, M.; Kishida, K.; Yamauchi, Y.; Sogabe, Y.

    1994-01-01

    A new test method has been developed to measure the resistance of dynamic fracture initiation in brittle materials under combined mode I/II loadings. The Brazilian disks with center-cracks have been fractured under oblique impact loadings in diametral-compression. The dynamic stress intensity factors of mode I and II are evaluated from the superposition integrals of the step response functions for the cracked disk. The experimental results are presented to elucidate the influence of loading rate on the combined mode fracture toughness for ceramics and glasses. (orig.)

  6. Effect of custom-made and prefabricated insoles on plantar loading parameters during running with and without fatigue.

    Science.gov (United States)

    Lucas-Cuevas, Angel Gabriel; Pérez-Soriano, Pedro; Llana-Belloch, Salvador; Macián-Romero, Cecili; Sánchez-Zuriaga, Daniel

    2014-01-01

    Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P heel compared to the prefabricated insoles. Finally, fatigue state did not influence plantar loading regardless the insole condition. In long-distance races, even a slight reduction in plantar loading at each foot strike may suppose a significant decrease in the overall stress experienced by the foot, and therefore the use of insoles may be an important protective mechanism for plantar overloading.

  7. Fatigue crack growth behaviour of carbon steel piping material subjected to single overload/under-load

    International Nuclear Information System (INIS)

    Arora, Punit; Tripathi, R.; Singh, P.K.; Bhasin, V.; Vijayan, P.K.

    2016-01-01

    The objective of the present study is to understand the Fatigue Crack Growth Rate (FCGR) behaviour after single over-load/ under-load event on carbon steel piping material. The tests have been carried out on standard Compact Tension (CT) specimens. The effect of different crack length to width ratio (a/W) of specimen and overload/under-load ratios on FCGR have been studied. The studies have shown significant reduction in FCG rate after overload event. The strain field has been measured using Digital Image Correlation (DIC) technique ahead of the crack tip to quantify the plastic zone size due to overload and constant amplitude load. In addition, plastic zone calculations have also been carried out using 3D finite element analyses for the prediction of post overload FCGR/ life. The predicted FCGR are in agreement with experimentally determined FCGR. (author)

  8. [Analysis on preparation and characterization of asiaticoside-loaded flexible nanoliposomes].

    Science.gov (United States)

    Ren, Yan; He, Xing-Dong; Shang, Bei-Cheng; Bao, Xiu-Kun; Wang, Yan-Fang; Ma, Ji-Sheng

    2013-10-01

    Asiaticoside is a compound extracted from traditional Chinese medicine Centella asiatica, and mainly used in wound healing and scar repair in clinical, with notable efficacy. However, its poor transdermal absorption and short action time restrict its wide application. In this experiment, the reserve-phase-extrusion-lyophilization method was conducted to prepare the lyophilized asiaticoside-loaded flexible nanoliposomes (LAFL). Its characteristics including electron microscope structure, particle size, Zeta potential, entrapment rate, drug-loading rate, stability and drug release were determined with the intelligent transdermal absorption instrument. LAFL were white spheroids, with pH, particle size and zeta potential of 7. 03, 70. 14 nm and - 36. 5 mV, respectively. The average entrapment rate of the 3 batch samples were 31. 43% , and the average asiaticoside content in 1 mg lyophilized simple was 0. 134 mg. The results indicated that LAFL have good physicochemical properties and pharmaceutical characteristics, with an improved transdermal performance.

  9. Fruit load governs transpiration of olive trees

    Science.gov (United States)

    Bustan, Amnon; Dag, Arnon; Yermiyahu, Uri; Erel, Ran; Presnov, Eugene; Agam, Nurit; Kool, Dilia; Iwema, Joost; Zipori, Isaac; Ben-Gal, Alon

    2016-01-01

    We tested the hypothesis that whole-tree water consumption of olives (Olea europaea L.) is fruit load-dependent and investigated the driving physiological mechanisms. Fruit load was manipulated in mature olives grown in weighing-drainage lysimeters. Fruit was thinned or entirely removed from trees at three separate stages of growth: early, mid and late in the season. Tree-scale transpiration, calculated from lysimeter water balance, was found to be a function of fruit load, canopy size and weather conditions. Fruit removal caused an immediate decline in water consumption, measured as whole-plant transpiration normalized to tree size, which persisted until the end of the season. The later the execution of fruit removal, the greater was the response. The amount of water transpired by a fruit-loaded tree was found to be roughly 30% greater than that of an equivalent low- or nonyielding tree. The tree-scale response to fruit was reflected in stem water potential but was not mirrored in leaf-scale physiological measurements of stomatal conductance or photosynthesis. Trees with low or no fruit load had higher vegetative growth rates. However, no significant difference was observed in the overall aboveground dry biomass among groups, when fruit was included. This case, where carbon sources and sinks were both not limiting, suggests that the role of fruit on water consumption involves signaling and alterations in hydraulic properties of vascular tissues and tree organs. PMID:26802540

  10. A constitutive model for AS4/PEEK thermoplastic composites under cyclic loading

    Science.gov (United States)

    Rui, Yuting; Sun, C. T.

    1990-01-01

    Based on the basic and essential features of the elastic-plastic response of the AS4/PEEK thermoplastic composite subjected to off-axis cyclic loadings, a simple rate-independent constitutive model is proposed to describe the orthotropic material behavior for cyclic loadings. A one-parameter memory surface is introduced to distinguish the virgin deformation and the subsequent deformation process and to characterize the loading range effect. Cyclic softening is characterized by the change of generalized plastic modulus. By the vanishing yield surface assumption, a yield criterion is not needed and it is not necessary to consider loading and unloading separately. The model is compared with experimental results and good agreement is obtained.

  11. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years. 23 refs., 9 tabs

  12. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1986-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane earthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years

  13. Advection and dispersion of bed load tracers

    Science.gov (United States)

    Lajeunesse, Eric; Devauchelle, Olivier; James, François

    2018-05-01

    We use the erosion-deposition model introduced by Charru et al. (2004) to numerically simulate the evolution of a plume of bed load tracers entrained by a steady flow. In this model, the propagation of the plume results from the stochastic exchange of particles between the bed and the bed load layer. We find a transition between two asymptotic regimes. The tracers, initially at rest, are gradually set into motion by the flow. During this entrainment regime, the plume is strongly skewed in the direction of propagation and continuously accelerates while spreading nonlinearly. With time, the skewness of the plume eventually reaches a maximum value before decreasing. This marks the transition to an advection-diffusion regime in which the plume becomes increasingly symmetrical, spreads linearly, and advances at constant velocity. We analytically derive the expressions of the position, the variance, and the skewness of the plume and investigate their asymptotic regimes. Our model assumes steady state. In the field, however, bed load transport is intermittent. We show that the asymptotic regimes become insensitive to this intermittency when expressed in terms of the distance traveled by the plume. If this finding applies to the field, it might provide an estimate for the average bed load transport rate.

  14. Quantitative analysis by X-ray fractography of fatigue fractured surface under variable amplitude loading

    International Nuclear Information System (INIS)

    Akita, Koichi; Kodama, Shotaro; Misawa, Hiroshi

    1994-01-01

    X-ray fractography is a method of analysing the causes of accidental fracture of machine components or structures. Almost all of the previous research on this problem has been carried out using constant amplitude fatigue tests. However, the actual loads on components and structures are usually of variable amplitudes. In this study, X-ray fractography was applied to fatigue fractured surfaces produced by variable amplitude loading. Fatigue tests were carried out on Ni-Cr-Mo steel CT specimens under the conditions of repeated, two-step and multiple-step loading. Residual stresses were measured on the fatigue fractured surface by an X-ray diffraction method. The relationships between residual stress and stress intensity factor or crack propagation rate were studied. They were discussed in terms of the quantitative expressions under constant amplitude loading, proposed by the authors in previous papers. The main results obtained were as follows : (1) It was possible to estimate the crack propagation rate of the fatigue fractured surface under variable amplitude loading by using the relationship between residual stress and stress intensity factor under constant amplitude loading. (2) The compressive residual stress components on the fatigue fractured surface correspond with cyclic softening of the material rather than with compressive plastic deformation at the crack tip. (author)

  15. Sensitivity of the polypropylene to the strain rate: experiments and modeling

    International Nuclear Information System (INIS)

    Abdul-Latif, A.; Aboura, Z.; Mosleh, L.

    2002-01-01

    Full text.The main goal of this work is first to evaluate experimentally the strain rate dependent deformation of the polypropylene under tensile load; and secondly is to propose a model capable to appropriately describe the mechanical behavior of this material and especially its sensitivity to the strain rate. Several experimental tensile tests are performed at different quasi-static strain rates in the range of 10 -5 s -1 to 10 -1 s -1 . In addition to some relaxation tests are also conducted introducing the strain rate jumping state during testing. Within the framework of elastoviscoplasticity, a phenomenological model is developed for describing the non-linear mechanical behavior of the material under uniaxial loading paths. With the small strain assumption, the sensitivity of the polypropylene to the strain rate being of particular interest in this work, is accordingly taken into account. As a matter of fact, since this model is based on internal state variables, we assume thus that the material sensitivity to the strain rate is governed by the kinematic hardening variable notably its modulus and the accumulated viscoplastic strain. As far as the elastic behavior is concerned, it is noticed that such a behavior is slightly influenced by the employed strain rate rage. For this reason, the elastic behavior is classically determined, i.e. without coupling with the strain rate dependent deformation. It is obvious that the inelastic behavior of the used material is thoroughly dictated by the applied strain rate. Hence, the model parameters are well calibrated utilizing several experimental databases for different strain rates (10 -5 s -1 to 10 -1 s -1 ). Actually, among these experimental results, some experiments related to the relaxation phenomenon and strain rate jumping during testing (increasing or decreasing) are also used in order to more perfect the model parameters identification. To validate the calibrated model parameters, simulation tests are achieved

  16. Development and Testing of a Rotating Detonation Engine Run on Hydrogen and Air

    Science.gov (United States)

    2012-03-22

    Jay Rutledge (Member) Date v AFIT/GAE/ENY/12-M36 Abstract Rotating detonation engines ( RDEs ) have the potential for greater...efficiencies over conventional engines by utilizing pressure gain combustion. A new modular RDE (6 in diameter) was developed and successfully run on...hydrogen and standard air. The RDE allows for variation of injection scheme and detonation channel widths. Tests provided the operational space of the

  17. Prediction of the metabolic cost of walking with and without loads.

    Science.gov (United States)

    Duggan, A; Haisman, M F

    1992-04-01

    Measurement of the metabolic cost of walking inconveniences subjects, and requires skilled technical support and expensive equipment. These factors have stimulated interest in predictive equations. The present study assessed existing equations. Under each of 17 combinations of gradient (0-6%) and carried load (4.1-37.4 kg), 7-12 men undertook treadmill walking at 1.67 m/s. Measured oxygen consumption and respiratory exchange ratio were used to calculate metabolic rate (MRobserved). Metabolic rate was also predicted from the equation of Pandolf et al. (1977) (MRpandolf) and, where appropriate, from another five equations relating to walking without loads. MRobserved and MRpandolf did not differ significantly (p greater than 0.05) under any combination of gradient and load. The overall mean MRobserved and MRpandolf of 609 W and 602 W, respectively, also did not differ significantly (p greater than 0.05). These variables were highly correlated (r = 0.94) with a standard deviation about the prediction error of 47 W. For level walking without loads, the mean predictions from the equations of Pandolf et al. (1977) and Cotes and Meade (1960) did not differ significantly (p greater than 0.05) from the mean MRobserved of 428 Watts, but four other equations overestimated by 17-74 W. In conclusion, the Pandolf et al. (1977) equation has given good results across the range of combinations of load and gradient tested, and the errors are considered acceptable for most practical purposes.

  18. Development of a dummy load and waveguide components for 1 MW CW gyrotron

    Energy Technology Data Exchange (ETDEWEB)

    Ioki, Kimihiro, E-mail: ioki@toyama-jp.com [Toyama Company Limited, 3816-1 Kishi, Ymakita-machi, Ashigarakami-gun, Kanagawa 258-0112 (Japan); Hiranai, Shinichi; Moriyama, Shinichi [Naka Fusion Institute, JAEA, 801-1, Mukoyama, Naka-shi, Ibaraki 311-0193 (Japan); Tanaka, Suguru [Toyama Company Limited, 3816-1 Kishi, Ymakita-machi, Ashigarakami-gun, Kanagawa 258-0112 (Japan)

    2016-11-01

    Highlights: • A dummy load is a required component for the electron cyclotron heating system to test and adjust a gyrotron or a transmission line in ITER and JT60SA. • A new design concept was developed considering reliable durability and long lifetime. • Linear movement is used as a main mechanism for the reflector to mitigate the heat deposition concentration instead of rotating reflector, and the vacuum boundary for the linear movement is simply made with bellows. • The distribution of the ceramic coating thickness is carefully optimized considering the heat deposition rate. • A prototypical dummy load will be manufactured and tested, following the design phase. - Abstract: A dummy load dissipates the radiofrequency power and is required for the electron cyclotron heating system to test and adjust a gyrotron or a transmission line in ITER and JT60SA. The dummy load is comprised of a water-cooled vacuum chamber and a reflector. The vacuum chamber has intensive cooling and the inside surface has a ceramic coating layer. It is important that the dummy load has reliable durability and long lifetime. Linear movement is used as a main mechanism for the reflector to mitigate the heat deposition concentration instead of rotating reflector. The vacuum boundary for the linear movement is simply made with bellows and the bellows is accessible from the outside. The distribution of the ceramic coating thickness is carefully optimized considering the heat deposition rate. Another critical issue is to minimize the back reflection of the RF power from the dummy load. However, it is desired to design the dummy load without the pre-dummy-load. A prototypical dummy load will be manufactured and tested, following the design phase.

  19. An analytical model for the ductile failure of biaxially loaded type 316 stainless steel subjected to thermal transients

    International Nuclear Information System (INIS)

    Dimelfi, R.J.

    1987-01-01

    Failure properties are calculated for the case of biaxially loaded type 316 stainless steel tubes that are heated from 300 K to near melting at various constant rates. The procedure involves combining a steady state plastic-deformation rate law with a strain hardening equation. Integrating under the condition of plastic instability gives the time and plastic strain at which ductile failure occurs for a given load. The result is presented as an analytical expression for equivalent plastic strain as a function of equivalent stress, temperature, heating rate and material constants. At large initial load, ductile fracture is calculated to occur early, at low temperatures, after very little deformation. At very small loads deformation continues for a long time to high temperatures where creep rupture mechanisms limit ductility. In the case of intermediate loads, the plastic strain accumulated before the occurrence of unstable ductile fracture is calculated. Comparison of calculated results is made with existing experimental data from pressurized tubes heated at 5.6 K/s and 111 K/s. When the effect of grain growth on creep ductility is taken into account from recrystallization data, agreement between measured and calculated uniform ductility is excellent. The general reduction in ductility and failure time that is observed at higher heating rate is explained via the model. The model provides an analytical expression for the ductility and failure time during transients for biaxially loaded type 316 stainless steel as a function of the initial temperature and load, as well as the material creep and strain hardening parameters. (orig.)

  20. Blade design loads on the flow exciting force in centrifugal pump

    International Nuclear Information System (INIS)

    Xu, Y; Yang, A L; Langand, D P; Dai, R

    2012-01-01

    The three-dimensional viscous flow field of two centrifugal pumps, which have the same volute, design head, design flow rate and rotational speed but the blade design load, are analyzed based on large eddy simulation. The comparisons are implemented including the hydraulic efficiencies, flow field characteristics, pressure pulsations and unsteady forces applied on the impellers to investigate the effect of the design blade load on hydraulic performance and flow exciting force. The numerical results show that the efficiency of the pump, the impeller blade of which has larger design load, is improved by 1.1%∼2.9% compared to the centrifugal pump with lower blade design load. The pressure fluctuation of the pump with high design load is more remarkable. Its maximum amplitude of coefficient of static pressure is higher by 43% than the latter. At the same time the amplitude of unsteady radial force is increased by 11.6% in the time domain. The results also imply that the blade design load is an important factor on the excitation force in centrifugal pumps.

  1. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A. [VTT Energy, Espoo (Finland)

    1996-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  2. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A [VTT Energy, Espoo (Finland)

    1997-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  3. Influence of boiler load on water tubes burnout

    Energy Technology Data Exchange (ETDEWEB)

    Said, S.A.M.; Habib, M.A.; Badr, H.M.; Mansour, R. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia). Dept. of Mechanical Engineering

    2009-07-01

    The influence of boiler loads on water tube burnout was investigated. The in-service boiler had 2 burners at different levels located in the front of the burner's wall. Homogenous-flow and separated-flow models were designed to simulate the water circulation and combustion processes inside the boiler tubes. Heat flux calculations were derived by solving the conservation of mass, momentum, and energy equations and species concentration as well as by solving turbulence, reaction rate, and radiation model equations. Results of the study showed that heat flux during full loads ranged from close to 0 to 270 kW/m2. The right side screen wall of the burner exhibited higher heat flux values in the middle region of the wall where large areas were subjected to heat flux close to a maximum of 270 kW/m2. Results also included reductions in heat flux values at partial loads. Maximum values were reduced from 270 kW/m2 ato 230 kW/m2 at 75 per cent capacity and 200 kW/m2 at 60 per cent capacity. The rate of steam generation increased from 0.1 kg/s to 0.153 kg/s when the distance from the burner wall increased from 2 meters to 12 meters. 10 refs., 10 figs.

  4. Sustainable Load-Balancing Scheme for Inter-Sensor Convergence Processing of Routing Cooperation Topology

    Directory of Open Access Journals (Sweden)

    Hyun-Woo Kim

    2016-05-01

    Full Text Available Recent advancements in Information Technology (IT have sparked the creation of numerous and diverse types of devices and services. Manual data collection measurement methods have been automated through the use of various wireless or wired sensors. Single sensor devices are included in smart devices such as smartphones. Data transmission is critical for big data collected from sensor nodes, such as Mobile Sensor Nodes (MSNs, where sensors move dynamically according to sensor mobility, or Fixed Sensor Nodes (FSNs, where sensor locations are decided by the users. False data transfer processing of big data results in topology lifespan reduction and data transfer delays. Hence, a variety of simulators and diverse load-balancing algorithms have been developed as protocol verification tools for topology lifespan maximization and effective data transfer processing. However, those previously developed simulators have limited functions, such as an event function for a specific sensor or a battery consumption rate test for sensor deployment. Moreover, since the previous load-balancing algorithms consider only the general traffic distribution and the number of connected nodes without considering the current topology condition, the sustainable load-balancing technique that takes into account the battery consumption rate of the dispersed sensor nodes is required. Therefore, this paper proposes the Sustainable Load-balancing Scheme (SLS, which maximizes the overall topology lifespan through effective and sustainable load-balancing of data transfer among the sensors. SLS is capable of maintaining an effective topology as it considers both the battery consumption rate of the sensors and the data transfer delay.

  5. Postural loading assessment in assembly workers of an Iranian telecommunication manufacturing company.

    Science.gov (United States)

    Kamalinia, Mojtaba; Nasl Saraji, Gebreal; Kee, Dohyung; Hosseini, Mostafa; Choobineh, Alireza

    2013-01-01

    Changes in industries and work practices have coincided with work-related musculoskeletal disorders (MSDs). This study was conducted to determine the prevalence of MSDs and to assess postural loading in assembly workers of an Iranian telecommunication manufacturing company. Data were collected from 193 randomly selected workers in 4 units of the company. The Nordic musculoskeletal disorders questionnaire and the UBC ergonomic checklist were used as data collection tools. Loading on the upper body assessment (LUBA) was used to assess postural loading. Lower back symptoms were the most prevalent problems among the workers (67.9%). LUBA showed that most assembly workers (94.3%) had experienced considerable and high postural loading (postural load index, PLI > 5). Regression analyses revealed that lighting, rotation, contact stress, repetition, gender and age were factors associated with symptoms. Work-related MSDs occurred at a high rate among workers. Postural loading requires consideration. Any ergonomic intervention should focus on eliminating ergonomic factors associated with symptoms.

  6. On rate-state and Coulomb failure models

    Science.gov (United States)

    Gomberg, J.; Beeler, N.; Blanpied, M.

    2000-01-01

    We examine the predictions of Coulomb failure stress and rate-state frictional models. We study the change in failure time (clock advance) Δt due to stress step perturbations (i.e., coseismic static stress increases) added to "background" stressing at a constant rate (i.e., tectonic loading) at time t0. The predictability of Δt implies a predictable change in seismicity rate r(t)/r0, testable using earthquake catalogs, where r0 is the constant rate resulting from tectonic stressing. Models of r(t)/r0, consistent with general properties of aftershock sequences, must predict an Omori law seismicity decay rate, a sequence duration that is less than a few percent of the mainshock cycle time and a return directly to the background rate. A Coulomb model requires that a fault remains locked during loading, that failure occur instantaneously, and that Δt is independent of t0. These characteristics imply an instantaneous infinite seismicity rate increase of zero duration. Numerical calculations of r(t)/r0 for different state evolution laws show that aftershocks occur on faults extremely close to failure at the mainshock origin time, that these faults must be "Coulomb-like," and that the slip evolution law can be precluded. Real aftershock population characteristics also may constrain rate-state constitutive parameters; a may be lower than laboratory values, the stiffness may be high, and/or normal stress may be lower than lithostatic. We also compare Coulomb and rate-state models theoretically. Rate-state model fault behavior becomes more Coulomb-like as constitutive parameter a decreases relative to parameter b. This is because the slip initially decelerates, representing an initial healing of fault contacts. The deceleration is more pronounced for smaller a, more closely simulating a locked fault. Even when the rate-state Δt has Coulomb characteristics, its magnitude may differ by some constant dependent on b. In this case, a rate-state model behaves like a modified

  7. A model for rate-dependent but time-independent material behavior in cyclic plasticity

    International Nuclear Information System (INIS)

    Dafalias, Y.F.; Ramey, M.R.; Sheikh, I.

    1977-01-01

    This paper presents a model for rate-dependent but time independent material behavior under cyclic loading in the plastic range. What is referred to as time independent behavior here, is the absence of creep and relaxation phenomena from the behavior of the model. The notion of plastic internal variables (piv) is introduced, as properly invariant scalars or second order tensors, whose constitutive relations are rate-type equations not necessarily homogeneous of order one in the rates, as it would be required for independent plasticity. The concept of a yield surface in the strain space and a loading function in terms of the total strain rate is introduced, where the sign of the loading function defines zero or non-zero value of the rate of piv. Thus rate dependence is achieved without time dependent behaviour (no creep or relaxation). In addition, discrete memory parameters associated with the most recent event of unloading-reloading in different directions enter the constitutive relations for the piv. (Auth.)

  8. Elastic-Plastic Behavior of U6Nb under Ramp Wave Loading

    International Nuclear Information System (INIS)

    Hayes, D. B.; Gray, G. T. III; Hixson, R. S.; Hall, C. A.

    2006-01-01

    When uranium-niobium (6 wt.%) alloy is shock loaded, the expected elastic precursor is absent. A prior model attributed this absence to shear-induced twinning and the concomitant shear stress reduction that prevented the shocked material from reaching the plastic yield point. In the present study, carefully prepared U6Nb was subjected to shock loading to verify the adequacy of the prior model. Other samples were loaded with a ramp pressure pulse with strain rate large enough so that significant twinning would not occur during the experiment. Backward integration analyses of these latter experiments' back surface motion give stress-strain loading paths in U6Nb that suggest ordinary elastic-plastic flow. Some of the U6Nb was pre-strained by cold rolling in an effort to further ensure that twinning did not affect wave propagation. Shock and ramp loadings yielded similar results to the baseline material except, as expected, they are consistent with a higher yield stress and twinning shear stress threshold

  9. Sensory ratings of emissions from nontraditional building materials

    DEFF Research Database (Denmark)

    Krejcirikova, Barbora; Kolarik, Jakub; Peuhkuri, Ruut

    2016-01-01

    Twenty-five subjects assessed the emissions from building materials: linoleum, cement mortar with and without fly ash, gypsum board and tiles with air cleaning properties and natural organic sheep wool. The ratings were made at different material loadings and in combinations with linoleum....... The results showed that except for natural organic product, increasing loading and combining materials with linoleum increased intensity of odor....

  10. Thermally determining flow and/or heat load distribution in parallel paths

    Science.gov (United States)

    Chainer, Timothy J.; Iyengar, Madhusudan K.; Parida, Pritish R.

    2016-12-13

    A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

  11. Compensation for Adolescents' School Mental Load by Physical Activity on Weekend Days.

    Science.gov (United States)

    Kudláček, Michal; Frömel, Karel; Jakubec, Lukáš; Groffik, Dorota

    2016-03-09

    Increasing mental load and inadequate stress management significantly affect the efficiency, success and safety of the educational/working process in adolescents. The objective of this study is to determine the extent that adolescents compensate for their school mental load by physical activity (PA) on weekend days and, thus, to contribute to the objective measurement of mental load in natural working conditions. A cross-sectional study was conducted between September 2013 and April 2014. A set of different methods was employed-self-administered questionnaire (IPAQ-long questionnaire), objective measurements-pedometers, and accelerometers (ActiTrainers). They was distributed to 548 students from 17 high schools. Participants' mental load was assessed based on the difference between PA intensity and/or physical inactivity and heart rate range. The participants with the highest mental load during school lessons do not compensate for this load by PA on weekend days. Adolescents need to be encouraged to be aware of their subjective mental load and to intentionally compensate for this load by PA on weekend days. It is necessary to support the process of adopting habits by sufficient physical literacy of students, as well as teachers, and by changes in the school program.

  12. Load leveling on industrial refrigeration systems

    Science.gov (United States)

    Bierenbaum, H. S.; Kraus, A. D.

    1982-01-01

    A computer model was constructed of a brewery with a 2000 horsepower compressor/refrigeration system. The various conservation and load management options were simulated using the validated model. The savings available for implementing the most promising options were verified by trials in the brewery. Result show that an optimized methodology for implementing load leveling and energy conservation consisted of: (1) adjusting (or tuning) refrigeration systems controller variables to minimize unnecessary compressor starts, (2) The primary refrigeration system operating parameters, compressor suction pressure, and discharge pressure are carefully controlled (modulated) to satisfy product quality constraints (as well as in-process material cooling rates and temperature levels) and energy evaluating the energy cost savings associated with reject heat recovery, and (4) a decision is made to implement the reject heat recovery system based on a cost/benefits analysis.

  13. Measurement of fatigue crack growth rate of reactor structural material in air based on DCPD method

    International Nuclear Information System (INIS)

    Du Donghai; Chen Kai; Yu Lun; Zhang Lefu; Shi Xiuqiang; Xu Xuelian

    2014-01-01

    The principles and details of direct current potential drop (DCPD) in monitoring the crack growth of reactor structural materials was introduced in this paper. Based on this method, the fatigue crack growth rate (CGR) of typical structural materials in nuclear power systems was measured. The effects of applied load, load ratio and loading frequency on the fatigue crack growth rate of reactor structural materials were discussed. The result shows that the fatigue crack growth rate of reactor structural materials depends on the hardness of materials, and the harder the material is, the higher the rate of crack growth is. (authors)

  14. High-dose rate brachytherapy in the treatment of carcinoma of uterine cervix: twenty-year experience with cobalt after-loading system.

    Science.gov (United States)

    Mosalaei, A; Mohammadianpanah, M; Omidvari, S; Ahmadloo, N

    2006-01-01

    This retrospective analysis aims to report results of patients with cancer of uterine cervix treated with external-beam radiotherapy (EBR) and high-dose rate (HDR) brachytherapy, using manual treatment planning. From 1975 to 1995, 237 patients with FIGO stages IIB-IVA and mean age of 54.31 years were treated. EBR dose to the whole pelvis was 50 Gy in 25 fractions. Brachytherapy with HDR after-loading cobalt source (Cathetron) was performed following EBR completion with a dose of 30 Gy in three weekly fractions of 10 Gy to point A. Survival, local control, and genitourinary and gastrointestinal complications were assessed. In a median follow-up of 60.2 months, the 10-year overall and disease-free survival rate was 62.4%. Local recurrence was seen in 12.2% of patients. Distant metastases to the lymph nodes, peritoneum, lung, liver, and bone occurred in 25.3% of patients. Less than 6% of patients experienced severe genitourinary and/or gastrointestinal toxicity that were relieved by surgical intervention. No treatment-related mortality was seen. This series suggests that 50 Gy to the whole pelvis together with three fractions of 10 Gy to point A with HDR brachytherapy is an effective fractionation schedule in the treatment of locally advanced cancer of cervix. To decrease the complications, newer devices and treatment planning may be beneficial.

  15. Objective and subjective methods for quantifying training load in wheelchair basketball small-sided games.

    Science.gov (United States)

    Iturricastillo, Aitor; Granados, Cristina; Los Arcos, Asier; Yanci, Javier

    2017-04-01

    The aim of the present study was to analyse the training load in wheelchair basketball small-sided games and determine the relationship between heart rate (HR)-based training load and perceived exertion (RPE)-based training load methods among small-sided games bouts. HR-based measurements of training load included Edwards' training load and Stagno's training impulses (TRIMP MOD ) while RPE-based training load measurements included cardiopulmonary (session RPEres) and muscular (session RPEmus) values. Data were collected from 12 wheelchair basketball players during five consecutive weeks. The total load for the small-sided games sessions was 67.5 ± 6.7 and 55.3 ± 12.5 AU in HR-based training load (Edwards' training load and TRIMP MOD ), while the RPE-based training loads were 99.3 ± 26.9 (session RPEres) and 100.8 ± 31.2 AU (session RPEmus). Bout-to-bout analysis identified greater session RPEmus in the third [P training loads. It is suggested that HR-based and RPE-based training loads provide different information, but these two methods could be complementary because one method could help us to understand the limitations of the other.

  16. Manipulation of Foot Strike and Footwear Increases Achilles Tendon Loading During Running.

    Science.gov (United States)

    Rice, Hannah; Patel, Mubarak

    2017-08-01

    The Achilles tendon is the most common site of tendon overuse injury in humans. Running with a forefoot strike pattern and in minimal shoes is a topic of recent interest, yet evidence is currently limited regarding the combined influence of foot strike and footwear on Achilles tendon loading. To investigate the influence of both foot strike and footwear on Achilles tendon loading in habitual rearfoot strike runners. Controlled laboratory study. Synchronized kinematic and force data were collected from 22 habitual rearfoot strikers (11 male), who habitually ran in nonminimal running shoes, during overground running at 3.6 m·s -1 . Participants ran in 3 different footwear conditions (standard running shoe, minimal running shoe, and barefoot) with both a rearfoot strike (RFS) and an imposed forefoot strike (FFS) in each footwear condition. Achilles tendon loading was estimated by use of inverse dynamics, where the Achilles tendon moment arm was determined with a regression equation. A 2-way, repeated-measures analysis of variance was used to compare conditions. Achilles tendon impulse was greater when subjects ran with an FFS rather than an RFS in minimal shoes. Achilles tendon loading rates were higher when subjects ran either in minimal shoes or barefoot than in standard shoes, regardless of foot strike. In runners who habitually rearfoot strike in standard running shoes, running in minimal shoes or barefoot increased the rate of tendon loading, and running with a forefoot strike in minimal shoes increased the magnitude of tendon loading. Transitioning to these running conditions may increase the risk of tendinopathy.

  17. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    Science.gov (United States)

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  18. Organic loading rate impact on biohydrogen production and microbial communities at anaerobic fluidized thermophilic bed reactors treating sugarcane stillage.

    Science.gov (United States)

    Santos, Samantha Christine; Rosa, Paula Rúbia Ferreira; Sakamoto, Isabel Kimiko; Varesche, Maria Bernadete Amâncio; Silva, Edson Luiz

    2014-05-01

    This study aimed to evaluate the effect of high organic loading rates (OLR) (60.0-480.00 kg COD m(-3)d(-1)) on biohydrogen production at 55°C, from sugarcane stillage for 15,000 and 20,000 mg CODL(-1), in two anaerobic fluidized bed reactors (AFBR1 and AFBR2). It was obtained, for H2 yield and content, a decreasing trend by increasing the OLR. The maximum H2 yield was observed in AFBR1 (2.23 mmol g COD added(-1)). The volumetric H2 production was proportionally related to the applied hydraulic retention time (HRT) of 6, 4, 2 and 1h and verified in AFBR1 the highest value (1.49 L H2 h(-1)L(-1)). Among the organic acids obtained, there was a predominance of lactic acid (7.5-22.5%) and butyric acid (9.4-23.8%). The microbial population was set with hydrogen-producing fermenters (Megasphaera sp.) and other organisms (Lactobacillus sp.). Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Bioelectrochemical enhancement of anaerobic methanogenesis for high organic load rate wastewater treatment in a up-flow anaerobic sludge blanket (UASB) reactor.

    Science.gov (United States)

    Zhao, Zhiqiang; Zhang, Yaobin; Chen, Shuo; Quan, Xie; Yu, Qilin

    2014-10-17

    A coupling process of anaerobic methanogenesis and electromethanogenesis was proposed to treat high organic load rate (OLR) wastewater. During the start-up stage, acetate removal efficiency of the electric-biological reactor (R1) reached the maximization about 19 percentage points higher than that of the control anaerobic reactor without electrodes (R2), and CH4 production rate of R1 also increased about 24.9% at the same time, while additional electric input was 1/1.17 of the extra obtained energy from methane. Coulombic efficiency and current recorded showed that anodic oxidation contributed a dominant part in degrading acetate when the metabolism of methanogens was low during the start-up stage. Along with prolonging operating time, aceticlastic methanogenesis gradually replaced anodic oxidation to become the main pathway of degrading acetate. When the methanogens were inhibited under the acidic conditions, anodic oxidation began to become the main pathway of acetate decomposition again, which ensured the reactor to maintain a stable performance. FISH analysis confirmed that the electric field imposed could enrich the H2/H(+)-utilizing methanogens around the cathode to help for reducing the acidity. This study demonstrated that an anaerobic digester with a pair of electrodes inserted to form a coupling system could enhance methanogenesis and reduce adverse impacts.

  20. Laguna Verde annulus pressurization loads evaluation

    International Nuclear Information System (INIS)

    Castaneda, M. A.; Cruz, M. A.; Cardenas, J. B.; Vargas, A.; Cruz, H. J.; Mercado, J. J.

    2010-10-01

    Annulus pressurization, jet impingement, pipe whip restraint and jet thrust are phenomena related to postulated pipe ruptures. A postulated pipe rupture at the weld between recirculation, or feedwater piping and a reactor nozzle safe end, will lead to a high flow rate of flashing water/steam mixture into the annulus between the reactor pressure vessel and the biological shield wall. The total effect of the vessel and pipe inventory blowdown from the break being postulated must be accounted for in the evaluation. A recirculation line break will give rise to an angular dependent short term pressure differential around the vessel, followed by a longer term pressure buildup in the annulus. A recirculation line postulated rupture may not produce worst case conditions and reference to time intervals for only the recirculation break should be treated superficially. A postulated rupture of the feedwater piping may produce the extreme case for determining: 1) the shield wall and reactor vessel to pedestal interactions, 2) loading on the reactor vessel internals, or 3) responses for the balance of piping attached to the vessel. Recently it was identified a potential issue regarding the criteria used to determine which cases were evaluated for Annulus Pressurization (A P) loads for new loads plants. The original A P loads methodology in the late 1970 and early 1980 years separated the mass/energy release calculation from the structural response calculation based on the implicit assumption that the maximum overall mass/energy release will result in maximizing the structural response and corresponding stresses on the reactor pressure vessel, internals, and containment structures. This process did not consider the dynamic response in the primary and secondary safety related structures, components and equipment. Consequently, the A P loads used as input for design adequacy evaluations of Nuclear Steam Supply System safety related components for new loads plants might have