  1. Daylight Science and Daylighting Technology

    CERN Document Server

    Kittler, Richard; Darula, Stanislav

    2012-01-01

    Sunlight profoundly influences the Earth's atmosphere and biosphere. Nature fuels the evolution of all living things, their visual systems, and the manner in which they adapt, accommodate, and habituate. Sun luminance measurements serve as data to calculate typical changes in the daily, monthly, and annual variability characteristics of daylight. Climate-based sky luminance patterns are used as models in predicting daylighting calculation and computer programs applied in architecture and building design. Historically, daylight science and daylighting technology has prioritized photometric methods of measurements, calculation, and graphical tools aimed at predicting or evaluating the daylighting of architectural design alternatives. However, due to a heightened awareness of general health and well-being, sunlight exposure and freedom from visual discomfort while undertaking visual tasks are now equally prioritized. Therefore, in order to assure optimal environmental quality, daylighting technology must be base...

  2. How daylight influences high-order chromatic descriptors in natural images.

    Science.gov (United States)

    Ojeda, Juan; Nieves, Juan Luis; Romero, Javier

    2017-07-01

    Despite the global and local daylight changes naturally occurring in natural scenes, the human visual system usually adapts quite well to those changes, developing a stable color perception. Nevertheless, the influence of daylight in modeling natural image statistics is not fully understood and has received little attention. The aim of this work was to analyze the influence of daylight changes in different high-order chromatic descriptors (i.e., color volume, color gamut, and number of discernible colors) derived from 350 color images, which were rendered under 108 natural illuminants with Correlated Color Temperatures (CCT) from 2735 to 25,889 K. Results suggest that chromatic and luminance information is almost constant and does not depend on the CCT of the illuminant for values above 14,000 K. Nevertheless, differences between the red-green and blue-yellow image components were found below that CCT, with most of the statistical descriptors analyzed showing local extremes in the range 2950 K-6300 K. Uniform regions and areas of the images attracting observers' attention were also considered in this analysis and were characterized by their patchiness index and their saliency maps. Meanwhile, the results of the patchiness index do not show a clear dependence on CCT, and it is remarkable that a significant reduction in the number of discernible colors (58% on average) was found when the images were masked with their corresponding saliency maps. Our results suggest that chromatic diversity, as defined in terms of the discernible colors, can be strongly reduced when an observer scans a natural scene. These findings support the idea that a reduction in the number of discernible colors will guide visual saliency and attention. Whatever the modeling is mediating the neural representation of natural images, natural image statistics, it is clear that natural image statistics should take into account those local maxima and minima depending on the daylight illumination and

  3. Tuning the diurnal natural daylight with phosphor converted white LED – Advent of new phosphor blend composition

    International Nuclear Information System (INIS)

    Kim, Yoon Hwa; Arunkumar, Paulraj; Park, Seung Hyok; Yoon, Ho Shin; Im, Won Bin

    2015-01-01

    Highlights: • Designed phosphor blend that mimics diurnal daylight for health benefits. • Developed new phosphor blend composition that mimics natural sunlight under near UV. • The phosphor blend also exhibits high CRI (≥90) under blue LED excitation. • Fabricated WLED exhibited ∼91% spectral resemblance with daylight at 4500 K. • While ∼39.2% spectral resemblance were observed for YAG:Ce 3+ at 4500 K. - Abstract: We demonstrate the feasibility of developing phosphor converted white LED (pc-WLED) that mimics diurnal natural daylight with the newly designed phosphor blend in the color temperature (CCT) 2700–6000 K for health benefits. Natural daylight (sunlight) spectrum possesses broad emission in the visible region and closely approximates black body radiator, with color rendition index (CRI) of 100 under wide CCT (2500–6500 K). Current white light LEDs although are efficient and durable, they are not broad enough compared to daylight. We report new phosphor blend based on Sr 3 MgSi 2 O 8 :Eu 2+ blue phosphor with broad emission and high CRI ≥ 96 under both near UV and blue excitation. The fabricated WLED has exhibited ∼91% spectral resemblance with natural daylight compared to 39.2% for YAG:Ce 3+ white LED at 4500 K. The developed phosphor blend tunes the spectrum in wider CCT and would be a prospective candidate for full spectrum daylight WLED

  4. Tuning the diurnal natural daylight with phosphor converted white LED – Advent of new phosphor blend composition

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Hwa [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Research Institute, Force4 Corp., Daechon-dong, Buk-gu, Gwangju 500-470 (Korea, Republic of); Arunkumar, Paulraj [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Park, Seung Hyok; Yoon, Ho Shin [Research Institute, Force4 Corp., Daechon-dong, Buk-gu, Gwangju 500-470 (Korea, Republic of); Im, Won Bin, E-mail: imwonbin@jnu.ac.kr [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of)

    2015-03-15

    Highlights: • Designed phosphor blend that mimics diurnal daylight for health benefits. • Developed new phosphor blend composition that mimics natural sunlight under near UV. • The phosphor blend also exhibits high CRI (≥90) under blue LED excitation. • Fabricated WLED exhibited ∼91% spectral resemblance with daylight at 4500 K. • While ∼39.2% spectral resemblance were observed for YAG:Ce{sup 3+} at 4500 K. - Abstract: We demonstrate the feasibility of developing phosphor converted white LED (pc-WLED) that mimics diurnal natural daylight with the newly designed phosphor blend in the color temperature (CCT) 2700–6000 K for health benefits. Natural daylight (sunlight) spectrum possesses broad emission in the visible region and closely approximates black body radiator, with color rendition index (CRI) of 100 under wide CCT (2500–6500 K). Current white light LEDs although are efficient and durable, they are not broad enough compared to daylight. We report new phosphor blend based on Sr{sub 3}MgSi{sub 2}O{sub 8}:Eu{sup 2+} blue phosphor with broad emission and high CRI ≥ 96 under both near UV and blue excitation. The fabricated WLED has exhibited ∼91% spectral resemblance with natural daylight compared to 39.2% for YAG:Ce{sup 3+} white LED at 4500 K. The developed phosphor blend tunes the spectrum in wider CCT and would be a prospective candidate for full spectrum daylight WLED.

  5. Daylight illumination-color-contrast tables for full-form objects naturally illuminated objects

    CERN Document Server

    Nagel, M

    1978-01-01

    Daylight Illumination-Color-Contrast Tables for Full-form Objects is the result of a major computational project concerning the illumination, color, and contrast conditions in naturally illuminated objects. The project from which this two-chapter book is derived is originally conceived in support of the various remote sensing and image processing activities of the Deutsche Forschungs- und Versuchsanstalt für Luft- und Raumfahrt, Oberpfaffenhofen, West Germany DFVLR, in particular, those depending on the quantitative photometric and colorimetric evaluation of photographs and other environmental

  6. The study on the computer analysis of solar daylighting system in the schoolroom

    Energy Technology Data Exchange (ETDEWEB)

    Oh, W. J.; Makhmudov, I.; Lee, Y. J.; Chun, W. G. [Jeju National University, Jeju (Korea, Republic of)

    2010-10-15

    Daylighting is the efficient use of natural light in order to minimize the need for artificial light in buildings. A well thought out building designed with daylighting can have a number of significant benefits for building owners and occupants. Increasing levels of daylight within rooms can reduce electrical lighting loads by up to 70% in some cases. In this study, the daylighting system using mini dish and optical fiber was analyzed for application to the schoolroom by the simulation of ECOTECT and RADIANCE

  7. Natural Light is the Right Light - Daylighting Design and Technology between Architecture, Art and Sustainability

    DEFF Research Database (Denmark)

    Osterhaus, Werner

    2009-01-01

    Within contemporary architecture, the art of daylighting design ? despite its many recognized advantages in comparison with electric lighting ? still encounters skepticism, primarily because it is usually developed and articulated more intuitively, rather than technically. Innovative daylighting ...... daylighting design with an open mind and an appreciation for basic human needs....... applications have added sparkle and interest to buildings. The sun?s rays have been captured to create magnificent plays of forms in light. People perceive daylight as an essential element of life. But architects, lighting designers, and clients alike, often underestimate the importance of daylight for human...

  8. Rethinking daylighting and compliance

    Directory of Open Access Journals (Sweden)

    John Mardaljevic

    2013-10-01

    Full Text Available Daylight in buildings is the natural illumination experienced by the occupants of any man-made construction with openings to the outside. Our attempts to formulate some measure of daylight provision in buildings can be traced back over a century, and the daylight factor as we know it today is over 50 years old. Still the most common measure found in guidelines and recommendations worldwide, the daylight factor is used routinely and, it is fair to say, often rather uncritically. The consideration of daylight in buildings has received a new impetus from the accumulation of evidence on the wider benefits of daylight exposure. But it is continuing to prove difficult to advance beyond daylight factors towards a more realistic quantification of daylighting performance that would allow us to accommodate these new considerations in an evaluative schema. This paper examines the basis of current practice with respect to daylight evaluation, and suggests a few ways in which it can be improved with relatively modest additional effort. The paper also critiques some of the recent attempts to advance daylight evaluation by incremental means using so-called “clear sky options”.

  9. Influence of daylight on the fate of silver and zinc oxide nanoparticles in natural aquatic environments

    International Nuclear Information System (INIS)

    Odzak, Niksa; Kistler, David; Sigg, Laura

    2017-01-01

    Nanoparticles, such as silver (Ag-NP) and zinc oxide (ZnO-NP), are increasingly used in many consumer products. These nanoparticles (NPs) will likely be exposed to the aquatic environment (rain, river, lake water) and to light (visible and UV) in the products where they are applied, or after those products are discharged. Dissolution of Ag-NP and ZnO-NP is an important process because the dissolved Ag + and Zn 2+ are readily available and toxic for aquatic organisms. The objective of this study was to investigate the role of daylight (UV and visible) for the fate of engineered Ag-NP and ZnO-NPs in different types of natural waters. Ag-NP and ZnO-NP were exposed to rainwater, river Rhine, and lake waters (Greifen, Lucerne, Cristallina, Gruère) under different light conditions (no light, UV 300–400 nm and visible light 400–700 nm) for up to 8 days. Stronger agglomeration of Ag-NP was observed in the waters with higher ionic strength in comparison to those with lower ionic strength. Visible light tended to increase the dissolution of Ag-NP under most natural water conditions in comparison to dark conditions, whereas UV-light led to decreased dissolved Ag + after longer exposure time. These effects illustrate the dynamic interactions of Ag-NP with light, which may lead both to increased oxidation and to increased reduction of Ag + by organic compounds under UV-light. In the case of ZnO-NP, agglomeration occurred at higher ionic strength, but the effects of pH were predominant for dissolution, which occurred up to concentrations close to the solubility limit of ZnO(s) at pH around 8.2 and to nearly complete dissolution of ZnO-NP at lower pH (pH 4.8–6.5), with both visible and UV-light facilitating dissolution. This study thus shows that light conditions play an important role in the dissolution processes of nanoparticles. - Highlights: • Effects of visible and UV-light on dissolution of silver and zinc oxide nanoparticles were examined. • Natural waters

  10. Influence of daylight on the fate of silver and zinc oxide nanoparticles in natural aquatic environments.

    Science.gov (United States)

    Odzak, Niksa; Kistler, David; Sigg, Laura

    2017-07-01

    Nanoparticles, such as silver (Ag-NP) and zinc oxide (ZnO-NP), are increasingly used in many consumer products. These nanoparticles (NPs) will likely be exposed to the aquatic environment (rain, river, lake water) and to light (visible and UV) in the products where they are applied, or after those products are discharged. Dissolution of Ag-NP and ZnO-NP is an important process because the dissolved Ag + and Zn 2+ are readily available and toxic for aquatic organisms. The objective of this study was to investigate the role of daylight (UV and visible) for the fate of engineered Ag-NP and ZnO-NPs in different types of natural waters. Ag-NP and ZnO-NP were exposed to rainwater, river Rhine, and lake waters (Greifen, Lucerne, Cristallina, Gruère) under different light conditions (no light, UV 300-400 nm and visible light 400-700 nm) for up to 8 days. Stronger agglomeration of Ag-NP was observed in the waters with higher ionic strength in comparison to those with lower ionic strength. Visible light tended to increase the dissolution of Ag-NP under most natural water conditions in comparison to dark conditions, whereas UV-light led to decreased dissolved Ag + after longer exposure time. These effects illustrate the dynamic interactions of Ag-NP with light, which may lead both to increased oxidation and to increased reduction of Ag + by organic compounds under UV-light. In the case of ZnO-NP, agglomeration occurred at higher ionic strength, but the effects of pH were predominant for dissolution, which occurred up to concentrations close to the solubility limit of ZnO(s) at pH around 8.2 and to nearly complete dissolution of ZnO-NP at lower pH (pH 4.8-6.5), with both visible and UV-light facilitating dissolution. This study thus shows that light conditions play an important role in the dissolution processes of nanoparticles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Designing with daylight; the relationship between daylight and health

    DEFF Research Database (Denmark)

    Hauge, Bettina

    2015-01-01

    and the significance of daylight. This paper describes the views and significance of daylight to people in their everyday lives. Based on a qualitative research project in Denmark about the use of windows, performed from May to August 2012 among 13 families , using in-depth interviews, observations, photos...... and postcards for storytelling, I will show how daylight is perceived, used, coped with, and negotiated by these people in their homes, thus exploring the social character of a natural phenomenon. A metaphor will be used from biomimetics (Benyus 1997), claiming that the Danish people, like plants, need daylight....... With the concept of ‘dwelling’ (Ingold 2000), which implies that people engage in their environment and create possibilities for dwelling at home to feel comfortable and at home in the world, I illustrate people’s day-to-day entanglements with daylight and highlight the social qualities of daylight. The paper...

  12. ADASY (Active Daylighting System)

    Science.gov (United States)

    Vázquez-Moliní, Daniel; González-Montes, Mario; Fernández-Balbuena, Antonio Á.; Bernabéu, Eusebio; García-Botella, Ángel; García-Rodríguez, Lucas; Pohl, Wilfried

    2009-08-01

    The main objective of ADASY (Active Daylighting System) work is to design a façade static daylighting system oriented to office applications, mainly. The goal of the project is to save energy by guiding daylight into a building for lighting purpose. With this approach we can reduce the electrical load for artificial lighting, completing it with sustainable energy. The collector of the system is integrated on a vertical façade and its distribution guide is always horizontal inside of the false ceiling. ADASY is designed with a specific patent pending caption system, a modular light-guide and light extractor luminaire system. Special care has been put on the final cost of the system and its building integration purpose. The current ADASY configuration is able to illuminate 40 m2 area with a 300lx-400lx level in the mid time work hours; furthermore it has a good enough spatial uniformity distribution and a controlled glare. The data presented in this study are the result of simulation models and have been confirmed by a physical scaled prototype. ADASY's main advantages over regular illumination systems are: -Low maintenance; it has not mobile pieces and therefore it lasts for a long time and require little attention once installed. - No energy consumption; solar light continue working even if there has been a power outage. - High quality of light: the colour rendering of light is very high - Psychological benefits: People working with daylight get less stress and more comfort, increasing productivity. - Health benefits

  13. New tools for the evaluation of daylighting strategies and technologies

    Energy Technology Data Exchange (ETDEWEB)

    Papamichael, K.; Hitchcock, R.; Ehrlich, C.; Carroll, B.

    1998-03-01

    The use of daylight for the illumination of building interiors has the potential to enhance the quality of the environment while providing opportunities to save energy by replacing or supplementing electric lighting. Moreover, it has the potential to reduce heating and cooling loads, which offer additional energy saving opportunities as well as reductions in HVAC equipment sizing and cost. All of these benefits, however, assume proper use of daylighting strategies and technologies, whose performance depends on the context of their application. On the other hand, improper use can have significant negative effects on both comfort and energy requirements, such as increased glare and cooling loads. To ensure proper use, designers need design tools that model the dynamic nature of daylight and accurately predict performance with respect to a multitude of performance criteria, extending beyond comfort and energy to include aesthetics, cost, security, safety, etc.

  14. Load Estimation from Natural input Modal Analysis

    DEFF Research Database (Denmark)

    Aenlle, Manuel López; Brincker, Rune; Canteli, Alfonso Fernández

    2005-01-01

    One application of Natural Input Modal Analysis consists in estimating the unknown load acting on structures such as wind loads, wave loads, traffic loads, etc. In this paper, a procedure to determine loading from a truncated modal model, as well as the results of an experimental testing programme...... estimation. In the experimental program a small structure subjected to vibration was used to estimate the loading from the measurements and the experimental modal space. The modal parameters were estimated by Natural Input Modal Analysis and the scaling factors of the mode shapes obtained by the mass change...

  15. Daylight calculations in practice

    DEFF Research Database (Denmark)

    Iversen, Anne; Roy, Nicolas; Hvass, Mette

    The aim of the project was to obtain a better understanding of what daylight calculations show and also to gain knowledge of how the different daylight simulation programs perform compared with each other. Experience has shown that results for the same room, obtained from two daylight simulation...... programs can give different results. This can be due to restrictions in the program itself and/or be due to the skills of the persons setting up the models. This is crucial as daylight calculations are used to document that the demands and recommendations to daylight levels outlined by building authorities....... The aim of the project was to obtain a better understanding of what daylight calculations show and also to gain knowledge of how the different daylight simulation programs perform compared with each other. Furthermore the aim was to provide knowledge of how to build up the 3D models that were...

  16. Capturing the Daylight Dividend

    Energy Technology Data Exchange (ETDEWEB)

    Peter Boyce; Claudia Hunter; Owen Howlett

    2006-04-30

    Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.

  17. Canister storage building natural phenomena design loads

    International Nuclear Information System (INIS)

    Tallman, A.M.

    1996-02-01

    This document presents natural phenomena hazard (NPH) loads for use in the design and construction of the Canister Storage Building (CSB), which will be located in the 200 East Area of the Hanford Site

  18. Daylight utilisation in office buildings

    DEFF Research Database (Denmark)

    Christoffersen, Jens

    This Ph.D. thesis presents the qualitative and quantitative consequences of full-scale measurements on two daylighting systems, light shelf and Venetian blinds. The systems were investigated to assess their ability to increase daylight penetration and improve daylight distribution in the interior...... the benefits and difficulties regarding use of daylight in office buildings, but it is hoped that the report will provide daylight conscious building design in forthcoming non-domestic buil dings....

  19. The daylight alternative for energy conservation saving in lighting systems; La luz natural alternativa para el ahorro de energia en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Escutia Perez, A.; Cruz Mendez, E. P. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico D. F. (Mexico); Buitron Sanchez, H. [Programa de Ahorro de Energia del Sector Electrico, Mexico D. F. (Mexico)

    1995-12-31

    The technological advances generate far reaching changes in all types of installation. The new spaces and the existing ones justify the introduction of new technologies taking into account important economic considerations, mostly when the advantage of daylight is taken into consideration in industrial and commercial lighting. In the daylight design it is necessary to know the solar transit, the atmospheric conditions, the architectural design of the building, the materials and the control elements, etc. to apply with precision the calculation method. The fundamental lighting technic have varied little. In the greatest part of commerces and industries the general lighting is used, that produces an illumination more or less uniform on the working areas, which guarantees a total freedom for the placement of machinery, working benches, racks, exhibitors, clothes racks, etc.. This type of lighting is obtained by means of the use of a more or less regular series of skylights. The adequate localized lighting is used in those zones where because of the presence of obstructions or unfavorable slant of the working plan are not sufficiently well lighted by the general lighting system. The daylight use in accordance with the every moment availability will permit in many working centers a sensible diminution of the artificial lighting time, provided that the characteristics of the control operation of the installation permit it, along with modern controlling devices and the great variety of efficient saving lamps. [Espanol] Los avances tecnologicos generan cambios trascendentes en todo tipo de instalacion. Los nuevos espacios y los ya existentes justifican la introduccion de nuevas tecnologias teniendo consideraciones economicas importantes, sobre todo cuando se aprovecha la luz natural en sistemas de alumbrado industrial y comercial. En el diseno de iluminacion natural, es necesario tener el conocimiento del transito solar, las condiciones atmosfericas, el diseno

  20. The daylight alternative for energy conservation saving in lighting systems; La luz natural alternativa para el ahorro de energia en sistemas de iluminacion

    Energy Technology Data Exchange (ETDEWEB)

    Escutia Perez, A; Cruz Mendez, E P [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico D. F. (Mexico); Buitron Sanchez, H [Programa de Ahorro de Energia del Sector Electrico, Mexico D. F. (Mexico)

    1996-12-31

    The technological advances generate far reaching changes in all types of installation. The new spaces and the existing ones justify the introduction of new technologies taking into account important economic considerations, mostly when the advantage of daylight is taken into consideration in industrial and commercial lighting. In the daylight design it is necessary to know the solar transit, the atmospheric conditions, the architectural design of the building, the materials and the control elements, etc. to apply with precision the calculation method. The fundamental lighting technic have varied little. In the greatest part of commerces and industries the general lighting is used, that produces an illumination more or less uniform on the working areas, which guarantees a total freedom for the placement of machinery, working benches, racks, exhibitors, clothes racks, etc.. This type of lighting is obtained by means of the use of a more or less regular series of skylights. The adequate localized lighting is used in those zones where because of the presence of obstructions or unfavorable slant of the working plan are not sufficiently well lighted by the general lighting system. The daylight use in accordance with the every moment availability will permit in many working centers a sensible diminution of the artificial lighting time, provided that the characteristics of the control operation of the installation permit it, along with modern controlling devices and the great variety of efficient saving lamps. [Espanol] Los avances tecnologicos generan cambios trascendentes en todo tipo de instalacion. Los nuevos espacios y los ya existentes justifican la introduccion de nuevas tecnologias teniendo consideraciones economicas importantes, sobre todo cuando se aprovecha la luz natural en sistemas de alumbrado industrial y comercial. En el diseno de iluminacion natural, es necesario tener el conocimiento del transito solar, las condiciones atmosfericas, el diseno

  1. THE CASE FOR DAYLIGHTING IN ARCHITECTURE

    Directory of Open Access Journals (Sweden)

    Barrett Richard

    2009-07-01

    Full Text Available The paper discusses the reasons for using daylight in the design of architectural form and space. These reasons extend from those of a practical nature, including energy conservation, cost factors, and health and wellbeing, to those of a more intangible, aesthetic nature. Some historical precedents are offered as examples of projects in which designing to maximize daylighting was crucial in the mind of the architect. By contrast there is also discussion relating to the ‘the lost art’ of using natural lighting in architecture. Some of the reasons for this loss of conviction and expertise are considered. The place of national building codes and other statutory requirements is examined, as is the role of the architect and his/her relationship with other professionals involved in daylighting design in architecture.

  2. Glazing for intelligent daylight utilisation; Verglasungen fuer die intelligente Tageslichtnutzung

    Energy Technology Data Exchange (ETDEWEB)

    Rubbert, F. [VEGLA Vereinigte Glaswerke GmbH, Aachen (Germany)

    1999-10-01

    Daylight, a part of the solar energy incident on the Earth`s surface, is available to us for free and usually in sufficient quantity. Nevertheless, in office and administration buildings artificial lighting is used for an average 60% of total occupancy time. This figure refers not only those times of the year and day when daylight intensity is naturally weak but also includes periods when sunlight is available in excess. To minimise buildings` absorption of solar energy (and so reduce the cooling load) and shield workplaces against direct sunlight, frequent use is made of mechanical shading systems which necessitate the use of artificial lighting, this in turn adding to the cooling load. Several daylight systems have been developed and are now increasingly being used to resolve this paradoxical situation. [Deutsch] Tageslicht, als Bestandteil der Sonnenenergie, steht uns taeglich kostenlos und meistens in ausreichender Menge zur Verfuegung. Dennoch wird in Buero- und Verwaltungsgebaeuden die kuenstliche Beleuchtung im Durchschnitt waehrend etwa 60% der Nutzungszeit eingeschaltet. Dies jedoch nicht nur waehrend der tages- und jahreszeitlich bedingten Phasen mit einer geringen natuerlichen aeusseren Beleuchtungsstaerke, sondern gerade auch zu den Zeiten in denen Sonnenlicht im Uebermass zur Verfuegung steht. Denn zur Minimierung der in die Gebaeude eingebrachten solaren Energie (Reduzierung der Kuehllasten) und zur Erzielung eines Blendschutzes an den betroffenen Arbeitsplaetzen werden sehr haeufig mechanische Verschattungssysteme benutzt, die ein Zuschalten der kuenstlichen Beleuchtung erforderlich machen und somit wieder zu einer Erhoehung der Kuehllasten fuehren. Um dieser Parodoxie aufzuloesen, wurden einige Tageslichtsysteme entwickelt, die im zunehmenden Masse auch praktisch angewandt werden. (orig.)

  3. The daylighting dashboard - A simulation-based design analysis for daylit spaces

    Energy Technology Data Exchange (ETDEWEB)

    Reinhart, Christoph F. [Harvard University, Graduate School of Design, 48 Quincy Street, Cambridge, MA 02138 (United States); Wienold, Jan [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, 79110 Freiburg (Germany)

    2011-02-15

    This paper presents a vision of how state-of-the-art computer-based analysis techniques can be effectively used during the design of daylit spaces. Following a review of recent advances in dynamic daylight computation capabilities, climate-based daylighting metrics, occupant behavior and glare analysis, a fully integrated design analysis method is introduced that simultaneously considers annual daylight availability, visual comfort and energy use: Annual daylight glare probability profiles are combined with an occupant behavior model in order to determine annual shading profiles and visual comfort conditions throughout a space. The shading profiles are then used to calculate daylight autonomy plots, energy loads, operational energy costs and green house gas emissions. The paper then shows how simulation results for a sidelit space can be visually presented to simulation non-experts using the concept of a daylighting dashboard. The paper ends with a discussion of how the daylighting dashboard could be practically implemented using technologies that are available today. (author)

  4. Thermal and Daylighting Performance of Energy-Efficient Windows in Highly Glazed Residential Buildings: Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Chang Heon Cheong

    2014-10-01

    Full Text Available Cooling load in highly glazed residential building can be excessively large due to uncontrolled solar energy entering the indoor space. This study focuses on the cooling load reduction and changes in the daylighting properties via the application of a double window system (DWS with shading with various surface reflectivities in highly glazed residential buildings. Evaluation of thermal and daylighting performances is carried out using simulation tools. The reductions in cooling load and energy cost through the use of DWS are evaluated through a comparative simulation considering conventional windows: a single window and a double window. Three variables of window types, natural ventilation, and shading reflectivity are reflected in the study. According to our results, implementation of DWS reduced cooling load by 43%–61%. Electricity cost during the cooling period was reduced by a maximum of 24%. However, a shading device setting that prioritizes effective cooling load reduction can greatly decrease the daylighting factor and luminance level of indoor space. A DWS implementing shading device with highly reflective at all surfaces is appropriate option for the more comfortable thermal and visual environment, while a shading device with low reflectivity at rear of the surface can contribute an additional 4% cooling load reduction.

  5. From dark to bright: novel daylighting applications in solid state lighting

    Science.gov (United States)

    Adler, Helmar G.

    2011-10-01

    The term "daylighting" is used in various ways, on one hand in a more architectural sense, i.e. using existing daylight to illuminate spaces, and on the other, more recently, for using light sources to replicate daylight. The emergence of solid state lighting (SSL) opens up a large number of new avenues for daylighting. SSL allows innovative controllability of intensity and color for artificial light sources that can be advantageously applied to daylighting. With the assistance of these new technologies the combination of natural and artificial lighting could lead to improvements in energy savings and comfort of living beings. Thus it is imperative to revisit or even improve daylighting research so that building networks of the future with their sensor, energy (e.g. HVAC) and lighting requirements can benefit from the emerging capabilities. This paper will briefly review existing daylighting concepts and technology and discuss new ideas. An example of a tunable multi-color SSL system will be shown.

  6. Lives under the Sun; The sensory qualities of daylight in designing the everyday

    DEFF Research Database (Denmark)

    Hauge, Bettina

    2015-01-01

    People’s sensations of daylight and their practical, daily engagements with the sun and the daylight are described in this article. Based on a qualitative research project in Denmark the article shows how some Danes experience the world through the sun and its daylight and illustrates its...... significance to their bodies and lives as they describe it. By taking a biomimetic approach a metaphor is presented that, like plants, some people crave daylight in order to feel well. By showing people’s engagement with the sun and its daylight the phenomenon of natural light becomes imbued with sociality...... and it is described how people design their everyday in accordance with the sun. The sensation of daylight normally taken for granted and acknowledged as a physiological element in our being-in-the-world is foregrounded and shown as a sense in people that may have a physiological origin when daylight hits the eye...

  7. Daylight prediction techniques in energy design tools

    Energy Technology Data Exchange (ETDEWEB)

    Milne, M.; Zurick, J. [California Univ., Los Angeles, Dept. of Architecture, CA (United States)

    1998-09-01

    Four different whole-building energy design tool systems that calculate energy savings from daylighting and that display annual performance on an-hour-by-hour basis, have been tested. The nature of design tools, the sources of hourly outdoor illuminance data, the ways of predicting indoor illumination, the assumptions of each tool, and the resulting energy savings of the design tools tested are discussed. The tests were carried out with the essential criteria for evaluating whole-building daylighting and energy design tools in mind. These have been identified as user confidence, accuracy, response time, and the amount of detail. Results of the tests, all four of them run on a single elementary school classroom for the sake of comparability, were provided. 9 refs., 2 figs.

  8. Investigation of Educational Buildings in Terms of Daylighting Performance

    Directory of Open Access Journals (Sweden)

    İlknur ERLALELİTEPE

    2011-01-01

    Full Text Available Educational buildings have the priority among other building types in daylight performance studies. There are several reasons for this. Classrooms which are used during the whole day should have sufficient and homogeneously distributed daylight. In insufficient daylight conditions, the use of electrical lighting increases energy consumption. Users’ visual comfort should also be assured, and design incorporating natural light requires the analysis of sun protection devices in order to avoid glare and excessive heat. Also, atriums and skylights can be included in the building design with the aim of distributing light equally and in a relatively balanced manner throughout the building. However, lighting schemes are often proposed by architects and professionals who tend to make use of different design tools, and it would be pertinent to investigate whether these tools perform as desired. This study analyses daylight design principles and design elements in educational buildings. It outlines the method which has been used to analyse the daylight performance of buildings. A university building was selected for the field study. Measurements were taken in sample spaces to determine daylight performance. Utilising comparison between standard values and measured values, findings are presented in the form of tables, drawings and figures.

  9. Daylighting on the working plane in oriented attic rooms under overcast and clear sky

    Directory of Open Access Journals (Sweden)

    Kondáš Kristián

    2014-06-01

    Full Text Available The evaluation of daylight conditions in building interiors is based on the Daylight Factor concept after current Slovak standards. Criteria and requirements determined in these standards consider the worst daylight exterior conditions which are described by CIE overcast sky model. The sky luminance distribution of overcast sky is centrical to the zenith, so independence of window orientation to cardinal points is characteristic in daylighting calculations. The sky luminance distribution modelling is one of the main task of the daylight source research more than 50 years. It is evident that also other types of sky conditions exist in nature. An introduction of a new criterion based on photometric variables, which also consider sunlight influence, is expected. This article represents a study of the influence of the interior orientation on distribution of daylighting in attic spaces under an overcast and clear sky

  10. Daylighting simulation: methods, algorithms, and resources

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, William L.

    1999-12-01

    This document presents work conducted as part of Subtask C, ''Daylighting Design Tools'', Subgroup C2, ''New Daylight Algorithms'', of the IEA SHC Task 21 and the ECBCS Program Annex 29 ''Daylight in Buildings''. The search for and collection of daylighting analysis methods and algorithms led to two important observations. First, there is a wide range of needs for different types of methods to produce a complete analysis tool. These include: Geometry; Light modeling; Characterization of the natural illumination resource; Materials and components properties, representations; and Usability issues (interfaces, interoperability, representation of analysis results, etc). Second, very advantageously, there have been rapid advances in many basic methods in these areas, due to other forces. They are in part driven by: The commercial computer graphics community (commerce, entertainment); The lighting industry; Architectural rendering and visualization for projects; and Academia: Course materials, research. This has led to a very rich set of information resources that have direct applicability to the small daylighting analysis community. Furthermore, much of this information is in fact available online. Because much of the information about methods and algorithms is now online, an innovative reporting strategy was used: the core formats are electronic, and used to produce a printed form only secondarily. The electronic forms include both online WWW pages and a downloadable .PDF file with the same appearance and content. Both electronic forms include live primary and indirect links to actual information sources on the WWW. In most cases, little additional commentary is provided regarding the information links or citations that are provided. This in turn allows the report to be very concise. The links are expected speak for themselves. The report consists of only about 10+ pages, with about 100+ primary links, but

  11. Evaluation of Daylight Intensity for Sustainbility in Residential Buildings in Cantonment Cottages Multan

    Directory of Open Access Journals (Sweden)

    SUMRA YOUSUF

    2017-07-01

    Full Text Available Day lighting is a useful and effective source of energy savings and visual comforts in buildings. Occupants expect good daylight in their living spaces for better living environment. The quality and quantity of natural light entering in to a building depend on both internal and external factors. Daylight strategies basically depend on the accessibility of natural light that is determined by the latitude of the building site and the conditions surrounding the building. Daylight provides lighting energy and energy demand reduction during peak utility hours. Bringing daylight into a building that displaces electric lighting and provides sufficient illumination is the greenest way to light a building presently. This research, aims at analyzing the daylight intensity in residential buildings in Cantonment Cottages Multan which is one of the hottest and progresse city of Pakistan. The intensity of daylight can be expressed in the terms of luminance and daylight factor. In this research, the 5 and 7 marla houses in Cantt Cottages in Multan were selected. The device lux meter was used for measuring intensity with which the brightness appears to the human eye. The readings were taken by placing Lux Meter at the center and near windows in each building component at 2-4 pm. Inorderto evaluate the daylight intensity, the measured luminance in each component of building is compared with the standard illuminance as per recommendation of CIBSE (Chartered Institute of Building Service Engineers. After investigation, it has been found that daylight factor is much higher than the standard values

  12. Experiences collected with a daylight system

    International Nuclear Information System (INIS)

    Krueger, P.

    1981-01-01

    The Kodak Daylight System is space-saving. It consists of the Kodak-X-Omat cassette, the identification camera and the loading and reloading device (cassette multiloader). All three units of this system are notable for extremely safe operation. Handling is simple and easily appreciated. All brands of film can be used. The data window in the cassette is too large; in some cases, important sections of the image can be covered up by the window. Automatic loading and reloading considerably reduces solling of the cassette, which is otherwise common, and also reduces abrasion of the intensifying screen. Introduction of this system has had a beneficial effect on overall working and has been welcomed by all concerned as a contribution towards facilitating routine work. (orig.) [de

  13. Daylight strategies for architectural studio facilities: the literature review

    Science.gov (United States)

    Othman, Muhammad Anas Bin; Azfahani Ahmad, Nur; Ajis, Azizah Md

    2017-05-01

    The implementation of daylighting strategies in buildings is a common aspect in architecture. However, due to the availability of inexpensive electricity, natural lighting strategies became insignificant, and been overlooked by designers. With the current concern over rapid increment on electricity cost, many designers now try to revitalized daylighting strategies in buildings. This includes educational buildings. In Malaysian cases, it is a norm that universities; especially during lecture and studio sessions, used artificial lighting throughout the day. Definitely, this is not parallel with the “green” aim made by the Government in the Malaysian Plan. Therefore, this paper aims to explore the impact of daylight strategies for educational studios in universities, by maximising the penetration of natural daylight into the space towards creating a more green-conducive studio. The paper review literature about the types, criteria and benefits of daylight strategies. This paper also presented a pilot study that has been performed in one university in Perak, Malaysia, by selecting architectural studios as the main subject.

  14. Colour Mixing Based on Daylight

    Science.gov (United States)

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large…

  15. Advanced fenestration and daylighting systems

    Energy Technology Data Exchange (ETDEWEB)

    McCluney, R. [Florida Solar Energy Centere, Cocoa, FL (United States)

    1998-09-01

    Advanced fenestration systems are new high-performance glazing and reflecting systems for otherwise conventional windows which offer specialized spectral and /or angular selectivity to provide improved illumination quantity and quality under optimal human comfort and energy conservation conditions. Advanced daylighting systems include systems manufactured by the solar lighting industry to introduce daylight into the core spaces of multi-storey buildings, spaces distant from the building envelope, or other locations where more conventional daylighting apertures cannot be placed. Details of operating, energy and illumination performance characteristics of both these systems were provided. It was concluded that solar lighting systems can effectively provide daylight illumination to interior spaces of a building that are not amenable to more conventional systems. Nevertheless, techniques need to be developed to predict the performance of such systems prior to their being built, so as to provide designers better means for justifying their use and economic viability, and to develop codes and performance standards to protect the consumer in the marketplace. 20 refs., 12 figs.

  16. Lightpipe applications for daylighting systems

    NARCIS (Netherlands)

    Rosemann, A.; Kaase, H.

    One of the main research activities of the Institute of Lighting at Technical University of Berlin concerns efficient daylight utilisation in buildings. In recent years, several national and international projects have been and are still carried out. One of them, the European research project

  17. Daylight as a building material

    DEFF Research Database (Denmark)

    Thule Kristensen, Peter; Madsen, Merete

    2005-01-01

    The article draws on examples to chronologically trace the use of daylight as building material in architecture of the 20th and early 21st century. The essay covers works of Mies van der Rohe, Le Corbusier, Erik Bryggman, Rudolf Schwarz, Alvar Aalto, Aldo Rossi, Jørn Utzon, Daniel Libeskind, Peter...

  18. Loading nature of the interfacial cracks in a joint component under fusion-relevant thermal loads

    International Nuclear Information System (INIS)

    You, J.H.

    1998-01-01

    One of the standard design concepts for divertor components in a fusion reactor is the bonded joint structure. Understanding the loading nature of interfacial cracks are significant for the assessment of structural integrity of divertor joint components. In this paper, the thermomechanical loading nature of interfacial cracks is discussed. A bi-material joint element consisting of the CFC/TZM system is considered. A typical fusion operation condition is simulated assuming a pulsed high heat flux loading. Stress singularities near the interfacial crack tips are characterized quantitatively in terms of the fracture mechanical parameters. The evolution of the stress intensity factors and the energy release rate during the given transient thermal load are determined. The difference in loading characteristics between the edge crack and the center crack is discussed. High heat flux cycling tests are performed on brazed CFC/TZM divertor elements in an electron beam test facility. The microstructures of the damaged interface agree with the predicted fracture modes. The loading nature and possible failure mechanisms are discussed for a fusion-relevant thermal loading. (orig.)

  19. Daylight photodynamic therapy for actinic keratosis

    DEFF Research Database (Denmark)

    Wiegell, Stine; Wulf, H C; Szeimies, R-M

    2011-01-01

    clinic visits and discomfort during therapy. In this article, we critically review daylight-mediated PDT, which is a simpler and more tolerable treatment procedure for PDT. We review the effective light dose, efficacy and safety, the need for prior application of sunscreen, and potential clinical scope...... of daylight-PDT. Three randomized controlled studies have shown that daylight-mediated PDT is an effective treatment of thin AKs. Daylight-mediated PDT is nearly pain-free and more convenient for both the clinics and patients. Daylight-mediated PDT is especially suited for patients with large field......-cancerized areas, which can easily be exposed to daylight. Further investigations are necessary to determine at which time of the year and in which weather conditions daylight-mediated PDT will be possible in different geographical locations....

  20. an investigation into the applicability of natural load variation

    African Journals Online (AJOL)

    Rev. Anoliefo

    Keywords – impedance matching,energy yield,natural load variation,maximum power ... Wind speed of 1 m/s and absolute air mass of 1.5 are also ... Unfortunately, solar modules operate under ..... thin-film photovoltaic plants by using physical.

  1. Colour mixing based on daylight

    International Nuclear Information System (INIS)

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large region of the colour space can be covered by mixing three primary colours derived from lossless spectral decomposition of daylight. These primaries are specified by hue, saturation and luminosity. Duality of additive and subtractive mixing is formulated quantitatively. Experimental demonstrations of calculated results are suggested. This paper is intended for undergraduate optics courses, and advanced interdisciplinary seminars on arts and physics

  2. Light and energy - daylight measurements

    Energy Technology Data Exchange (ETDEWEB)

    Christoffersen, Jens; Logadottir, A.; Traberg-Borup, S.; Barrie-Nielsen, K.

    2009-07-01

    All measurements where conducted in the spring of 2007, except the Interpane panel. The solar cell panels have been evaluated by three performance indicators to assess the daylight quantity within the room and the systems ability to maintain view to the outside. In the study, we used two performance indicators to assess the daylight quantity within the room: 1. the daylight factor (overcast sky) 2. the relative work plane illuminance (clear sky condition) Overcast sky: In general, all panels provided less daylight than the recommended requirement in the Danish Building Regulation of 2% on the work plane. This will most likely result in additional need for electric lighting. However, larger window areas and more parts of the facade with clear unobstructed glass may be one solution. Clear sky: In general, all panels provided less interior light levels than the two reference systems in the back of the room. Almost all systems aloud more or less direct sunlight in the window perimeter through the clear openings and additional needs for some kind of shading device is to be expected. Some systems blocked a large portion of the light in the majority of the room, and additional electric light in this part of the room may be needed. Only one performance indicator where used to describe the quality of the panels. View: In general, all panels, except two, obstruct the view significantly and cause figure/background confusion for a view position close to the window and the discrepancies of colour judgements. Only two systems provided a fairly clear view to the outside without to much distortion of the view. (au)

  3. Does Daylight Savings Time encourage physical activity?

    Science.gov (United States)

    Zick, Cathleen D

    2014-07-01

    Extending Daylight Savings Time (DST) has been identified as a policy intervention that may encourage physical activity. However, there has been little research on the question of if DST encourages adults to be more physically active. Data from residents of Arizona, Colorado, New Mexico, and Utah ages 18-64 who participated in the 2003-2009 American Time Use Survey are used to assess whether DST is associated with increased time spent in moderate-to-vigorous physical activity (MVPA). The analysis capitalizes on the natural experiment created because Arizona does not observe DST. Both bivariate and multivariate analyses indicate that shifting 1 hour of daylight from morning to evening does not impact MVPA of Americans living in the southwest. While DST may affect the choices people make about the timing and location of their sports/recreational activities, the potential for DST to serve as a broad-based intervention that encourages greater sports/recreation participation is not supported by this analysis. Whether this null effect would persist in other climate situations is an open question.

  4. An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin

    2015-01-01

    An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between...... abstract and blurred phenomena, these diffused luminous reflections rouse us into interactions with the world. In this book we are interested in identifying the qualitative parameters involved in the integration of dynamic artificial lighting and daylight; the latter being already highly dynamic by nature...... that examine how the dynamic artificial lighting in the observational instrument unfolds during the changing of the daylight situations that are generated by the weather outside. This research employs the concept of coupling between interior and exterior, in order to identify a spectrum of design parameters...

  5. Daylighting practices of the architectural industry (baseline results of a national survey)

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1990-05-01

    A national survey of over 300 commercial design architects was conducted to develop baseline information on their knowledge, perceptions, and use of daylighting in commercial building designs. Pacific Northwest Laboratory conducted the survey for the US Department of Energy's (DOE) Office of Building and Community Systems (BCS). In the survey daylighting was defined as the intentional use of natural light as a partial substitute for artificially generated light. The results suggested that architects need to be educated about the true benefits of daylighting and the impacts it can have on a building's energy performance. Educational programs that will increase the architects' understanding and awareness of modern daylighting technologies and practices should be developed by utilities, stage agencies, and the federal government. If more architects can be made aware of the true effectiveness and positive attributes of daylighting systems and technologies, daylighting may be used in more commercial buildings. The results of the survey show that the more familiar architects feel they are with daylighting, the more they use daylighting. 3 refs., 19 tabs.

  6. Daylighting, Space, and Architecture: A Literature Review

    Directory of Open Access Journals (Sweden)

    Dalia Hafiz

    2015-12-01

    Full Text Available Daylighting dynamism and constant change can characterize buildings and spaces with a living quality that cannot be achieved with any other design element. However, daylighting can create unwanted lighting conditions in the visual field causing discomfort and glare. This may affect the performance of building occupants such as workers or students. Consequently, designing for daylighting needs a good understanding of daylighting. Designers can rely on information from simulation software to re-imagine the space, especially to examine possible unexpected visual discomfort conditions.This paper aims to represent different visual comfort evaluation methods that can help decision-makers make better informed decisions. Different definitions and structures associated with daylight and glare are examined. It also presents a review of the literature of previous research conducted on daylighting, visual comfort analysis and glare studies.

  7. Daylight metrics and energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Mardaljevic, John; Heschong, Lisa; Lee, Eleanor

    2009-12-31

    The drive towards sustainable, low-energy buildings has increased the need for simple, yet accurate methods to evaluate whether a daylit building meets minimum standards for energy and human comfort performance. Current metrics do not account for the temporal and spatial aspects of daylight, nor of occupants comfort or interventions. This paper reviews the historical basis of current compliance methods for achieving daylit buildings, proposes a technical basis for development of better metrics, and provides two case study examples to stimulate dialogue on how metrics can be applied in a practical, real-world context.

  8. Daylighting Strategies Promote Healthy High Performance Buildings

    Science.gov (United States)

    Gille, Steve

    2010-01-01

    There are many reasons to incorporate daylighting into the building or renovation of K-16 learning facilities. Benefits include increased productivity for students and staff, improved health, a better connection to the outdoors, energy savings and better quality of light. Add the role daylighting can play in LEED certification and it's clear that…

  9. Adaptive integration of daylight and artificial lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve

    2016-01-01

    Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between the space inside and the world outside. The aperture or window itself constitutes the frame...... with the world. In contrast to fluctuating daylight, a specific distinctive feature of artificial light has been – until very recently – its constancy in colour and intensity. However, by virtue of the technological convertibility of LEDs in concert with digital control systems, LEDs are capable of dynamically...... producing variations in colour and intensity in ways that correspond to our experiences of the daylight. Daylight and artificial lighting are thus positioned in a new relationship to one another. Metaphorically, one can think of the adaptive software as ‘digital weather’ – as a self-generating and shifting...

  10. Evaluation of Daylight Availability for Energy Savings

    Directory of Open Access Journals (Sweden)

    Laura Bellia

    2015-06-01

    Full Text Available Dynamic daylight simulations are very useful instruments in daylighting design process. They allow an in depth analysis of indoor daylight availability levels and define if they are adequate to perform a particular visual task. Their results can be used to design shading devices or lighting control systems and compare different technical solutions. The use of these simulations is likely to spread in the common design practice since some regulations and green building rating systems suggest their use. This paper presents dynamic daylight simulation results related to an open-plan office, performed with Autodesk 3ds Max Design®, which is a calculation software validated by recent researches. It is not used in academic context but it is very widespread between technicians for photorenderings production purposes. The goal of this research is to demonstrate the functionality of this software also in dynamic daylight simulations field and propose an analysis' methodology to use it.

  11. Evaluation of daylight intensity for sustainbility in residential buildings in cantonment cottages multan

    International Nuclear Information System (INIS)

    Yousuf, S.; Maqsood, S.

    2017-01-01

    Day lighting is a useful and effective source of energy savings and visual comforts in buildings. Occupants expect good daylight in their living spaces for better living environment. The quality and quantity of natural light entering in to a building depend on both internal and external factors. Daylight strategies basically depend on the accessibility of natural light that is determined by the latitude of the building site and the conditions surrounding the building. Daylight provides lighting energy and energy demand reduction during peak utility hours. Bringing daylight into a building that displaces electric lighting and provides sufficient illumination is the greenest way to light a building presently. This research, aims at analyzing the daylight intensity in residential buildings in Cantonment Cottages Multan which is one of the hottest and progresse city of Pakistan. The intensity of daylight can be expressed in the terms of luminance and daylight factor. In this research, the 5 and 7 marla houses in Cantt Cottages in Multan were selected. The device lux meter was used for measuring intensity with which the brightness appears to the human eye. The readings were taken by placing Lux Meter at the center and near windows in each building component at 2-4 pm. In order to evaluate the daylight intensity, the measured luminance in each component of building is compared with the standard illuminance as per recommendation of CIBSE (Chartered Institute of Building Service Engineers). After investigation, it has been found that daylight factor is much higher than the standard values as per recommended by CIBSE. The design parameters including building orientation, glazing area, room size to window opening ratio etc. is not appropriate with respect to sustainable design. (author)

  12. Daylighting and energy performance of a building for composite climate: An experimental study

    OpenAIRE

    Madhu Sudan; G.N. Tiwari

    2016-01-01

    The present study includes overall energy saving through thermal as well as daylighting for composite climate for the building known as SODHA BERS COMPLEX (SBC) situated at Varanasi, India. The building has been designed including all the passive concepts for thermal comfort as well daylighting to maximize the use of natural lighting for the occupants in day to day activities. This approach can be useful for multi-story building for rural and urban areas for both residential and commercial bu...

  13. Assessment of daylight quality in simple rooms

    DEFF Research Database (Denmark)

    Johnsen, Kjeld; Dubois, Marie-Claude; Sørensen, Karl Grau

    The present report documents the results of a study on daylight conditions in simple rooms of residential buildings. The overall objective of the study was to develop a basis for a method for the assessment of daylight quality in a room with simple geometry and window configurations. As a tool...... in daylighting conditions for a number of lighting parameters. The results gave clear indications of, for instance, which room would be the brightest, under which conditions might glare be a problem and which type of window would yield the greatest luminous variation (or visual interest), etc....

  14. Daylight and absenteeism--evidence from Norway.

    Science.gov (United States)

    Markussen, Simen; Røed, Knut

    2015-01-01

    Based on administrative register data from Norway, we examine the impact of hours of daylight on sick-leave absences among workers. Our preferred estimates imply that an additional hour of daylight increases the daily entry rate to absenteeism by 0.5 percent and the corresponding recovery rate by 0.8 percent, ceteris paribus. The overall relationship between absenteeism and daylight hours is negative. Absenteeism is also sensitive to weather conditions. Heavy snowfall raises the incidence of absence during the winter, while warm weather reduces the probability of returning to work during the summer. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Balancing energy and daylighting performances for envelope design: A new index and proposition of a case study in Hong Kong

    International Nuclear Information System (INIS)

    Xie, Jing Chao; Xue, Peng; Mak, Cheuk Ming; Liu, Jia Ping

    2017-01-01

    Highlights: •Daylighting and energy performances were studied simultaneously. •Energy demands of lighting and air-conditioning systems were both included. •Luminous comfort was quantified by Ave. DA 300 with the range from 29.6% to 57.8%. •Energy Daylight Rate was proposed as a simple multi-objective optimization approach. •Optimal scenarios for all directions were tested and chosen by EDR method. -- Abstract: Being healthy and energy saving have become two important principles of building development. Daylight is an influential factor with the characteristics of both photometry and radiometry. Irradiance brings solar heat gains that transfer to building cooling load, while illuminance provides a luminous environment and affects artificial lighting system at the same time. To balance the energy and daylighting performances, it is reasonable to minimize the environmental load under moderate comfort conditions. This study first quantified luminous comfort with a dynamic daylighting metric, average daylight autonomy (Ave. DA 300 ), from a questionnaire survey and simulation work. The benchmark of this metric should range from 29.6% to 57.8% for high-rise residential buildings. With this guideline, the Hong Kong public housing units is found that part of units lack of daylight due to the high building floor and density, while some units have potential to save energy by compromising daylighting performance. Therefore, a new index, energy daylight rate (EDR), is proposed to help decide the best scenario of envelope design for both daylighting and shading purposes. The results show that opening a secondary window is an efficient way to bring more light in and lengthening overhang is an efficient way to block excessive sunlight. This method and the new index are proved to have the ability to help defining proper building envelope design at the early stage.

  16. Impacts of orientation on daylighting in high-rise office buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    AbdolHamid Mahdavi

    2015-12-01

    Full Text Available Orientation is one of the important factors in building design to use daylight and ‎conserve energy. Well-orientated buildings maximise daylight reception through ‎building facades and reduce the need for artificial lighting. Reasonable daylighting usage in office buildings is an important part of an architect’s designing process, which leads to lesser electricity consumption as well as providing a visual and thermal comfort for the occupants. Orientation is an important factor in passive design strategies. This paper focuses on the orientation effect on daylighting into office rooms. The research method of this study was simulation which is performed on a hypothetical model on a 25 storey high-rise office building in Malaysia. All simulations were carried out in the IES-VE software that uses RADIANCE program for illuminance calculations. To evaluate the daylight in various conditions, a new index SAZ was introduced which assesses daylight factor (DF and absolute Lux. Results showed similar SAZ in CIE overcast sky in various orientations; whereas, in sunny sky due to sun path in Malaysia, different results showed northern and southern rooms have the best illuminance distribution. However, the similar window form and size in four orientations lead to more energy consumption for artificial lighting and cooling loads.

  17. Daylight calculations using constant luminance curves

    Energy Technology Data Exchange (ETDEWEB)

    Betman, E. [CRICYT, Mendoza (Argentina). Laboratorio de Ambiente Humano y Vivienda

    2005-02-01

    This paper presents a simple method to manually estimate daylight availability and to make daylight calculations using constant luminance curves calculated with local illuminance and irradiance data and the all-weather model for sky luminance distribution developed in the Atmospheric Science Research Center of the University of New York (ARSC) by Richard Perez et al. Work with constant luminance curves has the advantage that daylight calculations include the problem's directionality and preserve the information of the luminous climate of the place. This permits accurate knowledge of the resource and a strong basis to establish conclusions concerning topics related to the energy efficiency and comfort in buildings. The characteristics of the proposed method are compared with the method that uses the daylight factor. (author)

  18. Welcome to the Journal of Daylighting

    Directory of Open Access Journals (Sweden)

    Irfan Ullah

    2014-12-01

    Full Text Available I am delighted to welcome you to a newly launched Solarlits electronic journal: the Journal of Daylighting (JD. As the Editor-in-Chief of JD it is a great pleasure to introduce the inaugural issue of this new, open-access, bi-annual journal to readers, researchers, future authors, and colleagues. The decision by SolarLits to launch this new journal is very timely. Because the growth of lighting demand is increasing due to rising average illuminance levels in buildings, more attention has been paid to introduce daylighting in buildings, which will sustainably reduce the overall energy consumption in buildings. JD will serve as a new international platform for researchers to share advances in daylighting. As an international, peer-reviewed research journal it will exclusively cover the vibrant and diverse field of daylighting technologies and applications. JD will serve as an interdisciplinary forum for the scientific and research community active in daylighting and its applications. Topics will include, but not limited to: daylighting and hybrid lighting systems, lighting and daylighting simulation, lighting designs, lighting metrology and light quality, lighting control, building physics - lighting, building energy modeling, energy efficient buildings, zero-energy buildings, indoor environment quality, sustainable solar energy systems, application of solar energy sources in buildings, building-integrated photovoltaics, and solar thermal and concentrator technology. I will work with the Associate Editors, the Editorial Board, and the scientific and engineering research community to make JD a primary journal for the dissemination of breakthrough results, discussion of key challenges, and topics in daylighting. JD will publish full-length research articles, review articles, book reviews, and short communications.

  19. Modeling daylight from solar irradiation in Malaysia

    International Nuclear Information System (INIS)

    Ahmed, A.Z.; Sayigh, A.A.K.; Surendran, P.N.; Othman, M.Y.

    1999-01-01

    The oil crises in the seventies, the environmental impact by the extensive use of energy in the nineties and the recent economic recession in Asia have led to the rediscovery of the use of daylight in energy-conscious design in buildings, the economic implication of the excessive use of artificial lighting in potential of daylight. No daylight data is currently available in Malaysia and therefore there is a need to model the daylight availability based on other climatic parameters measured at meteorological stations. A study has been carried out to produce daylight data from measured climatic parameters, specifically solar irradiation and could cover. The Model Year Climate (MYC) data for the location of Subang (3 deg. 7', N 101 deg. 33' E), model to estimate daily diffuse irradiation was produced the average values of global (KG) and diffuse (KD) luminous efficacious were calculated and found to be 112 lm/W and 120 lm/W respectively. The value of 104 lm/W for the beam luminous efficacy (KB) was selected. Using cloud data cover data as input parameters, the nebulosity index was calculated to determine the sky condition in Subang, Malaysia, which was then classified as average or intermediate sky type, the hourly illuminance on horizontal and inclined surfaces at locations with similar sky conditions in Malaysia were then produced. (author)

  20. The nature of wind turbine fatigue loads in wind farms

    DEFF Research Database (Denmark)

    Larsen, Gunner Chr.; Larsen, Torben J.; Aagaard Madsen, Helge

    2013-01-01

    The aim of the present paper is to further validate the predictive capability of the DWM/HAWC2 package for simulation of structural loadings in wind farms. The validation in particular focus on tower fatigue loading characteristics (i.e. equivalent moments) as function of turbine relative positio...

  1. Comparative Study of Daylighting Calculation Methods

    Directory of Open Access Journals (Sweden)

    Mandala Ariani

    2018-01-01

    Full Text Available The aim of this study is to assess five daylighting calculation method commonly used in architectural study. The methods used include hand calculation methods (SNI/DPMB method and BRE Daylighting Protractors, scale models studied in an artificial sky simulator and computer programs using Dialux and Velux lighting software. The test room is conditioned by the uniform sky conditions, simple room geometry with variations of the room reflectance (black, grey, and white color. The analyses compared the result (including daylight factor, illumination, and coefficient of uniformity value and examines the similarity and contrast the result different. The color variations trial is used to analyses the internally reflection factor contribution to the result.

  2. A review of daylight illuminance determinations and energy implications

    Energy Technology Data Exchange (ETDEWEB)

    Li, Danny H.W. [Building Energy Research Group, Department of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR (China)

    2010-07-15

    Daylighting is recognized as an important element in architecture and a useful strategy in energy-efficient building designs. Daylight gives a sense of cheeriness and brightness that can have a significant positive impact on the people. There is a scope for integrating daylight with electric light to reduce building energy use. The amount of daylight entering a building is mainly through window openings, which create in the indoor environment a more attractive and pleasing atmosphere, in addition to maximise visual access to the pleasant views of the outside world. Determinations of the exterior and interior daylight and lighting energy savings are key issues to demonstrate the benefits based on daylighting designs. This paper provides a review of daylight illuminance determinations and the lighting energy reductions due to daylighting schemes. The study includes daylight measurements, prediction of daylight illuminance under various sky conditions and potential electric lighting energy savings from daylight-linked lighting controls. The article aims at providing building professionals, practitioners and researchers more information and a better understanding of daylight for promoting effective daylighting designs and evaluations. (author)

  3. Energy savings due to daylight and artificial lighting integration in office buildings in hot climate

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ashwal, Nagib T. [Sana' a University, Sana' a (Yemen); Budaiwi, Ismail M. [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2011-07-01

    Reducing energy consumption while maintaining acceptable environmental quality in buildings has been a challenging task for building professionals. In office buildings, artificial lighting systems are a major consumer of energy and can significantly contribute to building cooling load. Furthermore, although reliable, artificial lighting does not necessarily provide the required quality of lighting. Significant improvement in lighting quality and energy consumption can be achieved by proper integration of daylight and artificial lighting. The objective of this study is to investigate the energy performance of office buildings resulting from daylight and artificial lighting integration in hot climates. A parametric analysis is conducted to find the impact of different window design parameters, including window area, height and glazing type, on building energy performance. Results have shown that as much as 35% reduction in lighting energy consumption and 13% reduction in total energy consumption can be obtained when proper daylighting and artificial lighting integration is achieved.

  4. Application and Computer Analysis of Solar Systems for the Indoor Daylighting

    International Nuclear Information System (INIS)

    Makhmudov, Is Kandar

    2010-02-01

    A steady increase of energy costs and ever growing environmental concerns in recent years have forced scientists to look for new methods of energy utilization. To resolve these dire problems, the application of renewable energy sources has been considered in various human activities in every sector of society. One of them is the development of solar daylighting systems for residential and commercial buildings, which can improve building energy efficiency and create comfortable indoor environment. Electric lighting represents up to 30 % of building electricity consumption. Therefore, using sunlight in indoor daylighting can significantly reduce electricity consumption in residential and commercial buildings. Moreover, daylight is an important factor in visual environment and improving human well-being. In last decades, different approaches to the design of solar daylighting systems have resulted in various innovative solutions to efficiently introduce natural light in buildings. But their efficiency and cost are still one of primary obstacles in the wider development and distribution of solar daylighting systems. In this study, we investigated the performance of a new solar concentrator system for indoor illumination. The solar concentrator system consists of 30 cm dish concentrators, high precision solar trackers, optical fibers and diffusers for a light distribution. In order to assess the daylighting system's efficiency, there were carried out several experimental measurement series. One of them was an application of our solar daylighting system to two standard classrooms with south- and north-oriented windows in Jeju city, Korea. At the same time classrooms were modeled by using ECOTECT and exported to RADIANCE for daylighting simulations. Results from the measurements and simulations were analyzed comprehensively to establish the reliability of the modeling process. Following this, we modeled both classrooms with the above mentioned daylighting systems

  5. Analysis of daylight calculated using the EnergyPlus programme

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Greici; Ghisi, Enedir [Universidade Federal de Santa Catarina, Departamento de Engenharia Civil, Laboratorio de Eficiencia Energetica em Edificacoes, Caixa Postal 476, Florianopolis - SC 88040-900 (Brazil)

    2010-09-15

    In order to properly evaluate the thermal energy performance of buildings it is also necessary to analyse the use of daylight, since this influences the thermal load of a building. In this context, the aim of this study was to evaluate the calculation of internal illuminances carried out using the EnergyPlus simulation programme. The analysis was carried out through a comparison of the Useful Daylight Illuminances (UDI) and the daylight factor (DF) estimated using the EnergyPlus programme with the results from another two programmes: Daysim/Radiance and TropLux. Also, the external horizontal illuminance estimated using EnergyPlus was compared with that measured in Florianopolis, Santa Catarina State, Brazil, between 2003 and 2005. The simulations were carried out for three different rooms: one square (5 m x 5 m x 3 m), one shallow rectangular (10 m x 5 m x 3 m) and one deep rectangular (5 m x 10 m x 3 m). From this analysis it was verified that the EnergyPlus programme has a problem related to both the DF and the external illuminance values. A comparison between the DF values calculated using the three programmes shows that there is a problem in EnergyPlus related to solving the internal reflection, such that the greater the importance of the portion of light reflected, the greater the difference found between the programmes. A comparison between the calculated and measured external horizontal illuminances shows differences greater than 100% both for the diffuse and direct illuminances indicating that the EnergyPlus programme overestimates these values. (author)

  6. Workplane Illuminance Estimation for Robust Daylight Harvesting Lighting Control

    NARCIS (Netherlands)

    Zhang, S.; Birru, D.

    2012-01-01

    Daylight harvesting lighting controls can provide significant energysavings in daylit spaces. However, their performance is affected bythe changing lighting distribution in the space due to window treatments and the sun. Such impacts reduce the field performance of daylight harvesting dimming

  7. Weather conditions and daylight-mediated photodynamic therapy

    DEFF Research Database (Denmark)

    Wiegell, S R; Fabricius, S; Heydenreich, J

    2013-01-01

    Photodynamic therapy (PDT) is an attractive therapy for nonmelanoma skin cancers and actinic keratoses (AKs). Daylight-mediated methyl aminolaevulinate PDT (daylight-PDT) is a simple and painless treatment procedure for PDT. All daylight-PDT studies have been performed in the Nordic countries...

  8. The impact of windows and daylight on acute-care nurses' physiological, psychological, and behavioral health.

    Science.gov (United States)

    Zadeh, Rana Sagha; Shepley, Mardelle McCuskey; Williams, Gary; Chung, Susan Sung Eun

    2014-01-01

    To investigate the physiological and psychological effects of windows and daylight on registered nurses. To date, evidence has indicated that appropriate environmental lighting with characteristics similar to natural light can improve mood, alertness, and performance. The restorative effects of windows also have been documented. Hospital workspaces generally lack windows and daylight, and the impact of the lack of windows and daylight on healthcare employees' well being has not been thoroughly investigated. Data were collected using multiple methods with a quasi-experimental approach (i.e., biological measurements, behavioral mapping, and analysis of archival data) in an acute-care nursing unit with two wards that have similar environmental and organizational conditions, and similar patient populations and acuity, but different availability of windows in the nursing stations. Findings indicated that blood pressure (p windows and daylight. A possible micro-restorative effect of windows and daylight may result in lowered blood pressure and increased oxygen saturation and a positive effect on circadian rhythms (as suggested by body temperature) and morning sleepiness. Critical care/intensive care, lighting, nursing, quality care, work environment.

  9. Daylight Adaptive Shading Using Parametric Camshaft Mechanism for SOHO in Jakarta

    Directory of Open Access Journals (Sweden)

    Sjarifudin Firza Utama

    2014-03-01

    Full Text Available This research analyzes SOHO (Small Office Home Office which can adjust to the need of visual comfort for the users through natural daylighting and also can be adapted to standard requirements of 14 creative industry workspace in Jakartas. The method of the research is by simulating the SOHO unit with variation of shading opening angles in order to adapt to each unit. Analysis done to every shading opening angle to get the appropriate daylight intensity level which support the work activities in every unit for the whole day. In order for the shading to be able to adapt to the changing daylight condition, previously developed parametric camshaft mechanism was used. The study found that the visual comfort for SOHO with creative industries workers in Jakarta can be achieve by varying the shading opening angles between 15-75°.

  10. Structural evaluation of safety class components to natural phenomena loadings

    International Nuclear Information System (INIS)

    Conrads, T.J.

    1989-01-01

    This paper addresses the efforts completed at the US Department of Energy Hanford Site near Richland, Washington, to qualify structurally a number of existing safety class components in the Plutonium Finishing Plant complex. Design, fabrication, and installation of the facility occurred in the 1950s and 1960s and were based on the Uniform Building Code criteria for wind and earthquake loads. Recently the buildings were qualified to site-specific wind and seismic hazards. The methodology employed to qualify seismically the safety class components is discussed

  11. A spatially augmented reality sketching interface for architectural daylighting design.

    Science.gov (United States)

    Sheng, Yu; Yapo, Theodore C; Young, Christopher; Cutler, Barbara

    2011-01-01

    We present an application of interactive global illumination and spatially augmented reality to architectural daylight modeling that allows designers to explore alternative designs and new technologies for improving the sustainability of their buildings. Images of a model in the real world, captured by a camera above the scene, are processed to construct a virtual 3D model. To achieve interactive rendering rates, we use a hybrid rendering technique, leveraging radiosity to simulate the interreflectance between diffuse patches and shadow volumes to generate per-pixel direct illumination. The rendered images are then projected on the real model by four calibrated projectors to help users study the daylighting illumination. The virtual heliodon is a physical design environment in which multiple designers, a designer and a client, or a teacher and students can gather to experience animated visualizations of the natural illumination within a proposed design by controlling the time of day, season, and climate. Furthermore, participants may interactively redesign the geometry and materials of the space by manipulating physical design elements and see the updated lighting simulation. © 2011 IEEE Published by the IEEE Computer Society

  12. Multiobjective generalized extremal optimization algorithm for simulation of daylight illuminants

    Science.gov (United States)

    Kumar, Srividya Ravindra; Kurian, Ciji Pearl; Gomes-Borges, Marcos Eduardo

    2017-10-01

    Daylight illuminants are widely used as references for color quality testing and optical vision testing applications. Presently used daylight simulators make use of fluorescent bulbs that are not tunable and occupy more space inside the quality testing chambers. By designing a spectrally tunable LED light source with an optimal number of LEDs, cost, space, and energy can be saved. This paper describes an application of the generalized extremal optimization (GEO) algorithm for selection of the appropriate quantity and quality of LEDs that compose the light source. The multiobjective approach of this algorithm tries to get the best spectral simulation with minimum fitness error toward the target spectrum, correlated color temperature (CCT) the same as the target spectrum, high color rendering index (CRI), and luminous flux as required for testing applications. GEO is a global search algorithm based on phenomena of natural evolution and is especially designed to be used in complex optimization problems. Several simulations have been conducted to validate the performance of the algorithm. The methodology applied to model the LEDs, together with the theoretical basis for CCT and CRI calculation, is presented in this paper. A comparative result analysis of M-GEO evolutionary algorithm with the Levenberg-Marquardt conventional deterministic algorithm is also presented.

  13. Integration Issues for Using Innovative Daylighting Strategies in Light Wells

    Directory of Open Access Journals (Sweden)

    Gashinani M. Gholipour

    2017-12-01

    Full Text Available “Light well” as one of the most common means of daylight tolls in building, experiences severe limitations and deserve special attention. The question is which strategy is the best for increasing the daylight penetration to the depth of buildings. One of the main challenges in deep plan is to guide daylight into the building core and this can be performed through daylighting strategies, but the choice of the proper innovative daylighting system (IDS with several parameters is the problem. This paper aims to find elements for optimal choice and selecting context-compatible tools for light well. The result shows that four macro factors were found at the interaction of building and IDS. Identifying the integration components can play an effective role in decision-making or design a new tolls consistent with the physical conditions of light well and building to overcome the daylight crisis.

  14. Performance of a daylight-redirecting glass-shading system

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend

    2013-01-01

    to the original system. The visual comfort was evaluated by glare analysis and the redirected daylight did not cause an additional discomfort glare. The higher utilization of daylight can save 20% of the lighting energy. The thermal insulation of the fenestration was maintained, with slightly increased solar......This paper evaluates the daylighting performance of a prototype external dynamic shading and daylight-redirecting system, and the main focus is on the performance simulation. The demonstration project was carried out on a building with an open-plan office. Part of the original façade was replaced...... with the prototype façade. This layout allowed the use of the same orientation and surroundings for both façades. The working plane illuminance was measured over several months and the measurements were accompanied with annual daylight simulations. The prototype system improved the daylighting conditions compared...

  15. Load compensation in a lean burn natural gas vehicle

    Science.gov (United States)

    Gangopadhyay, Anupam

    A new multivariable PI tuning technique is developed in this research that is primarily developed for regulation purposes. Design guidelines are developed based on closed-loop stability. The new multivariable design is applied in a natural gas vehicle to combine idle and A/F ratio control loops. This results in better recovery during low idle operation of a vehicle under external step torques. A powertrain model of a natural gas engine is developed and validated for steady-state and transient operation. The nonlinear model has three states: engine speed, intake manifold pressure and fuel fraction in the intake manifold. The model includes the effect of fuel partial pressure in the intake manifold filling and emptying dynamics. Due to the inclusion of fuel fraction as a state, fuel flow rate into the cylinders is also accurately modeled. A linear system identification is performed on the nonlinear model. The linear model structure is predicted analytically from the nonlinear model and the coefficients of the predicted transfer function are shown to be functions of key physical parameters in the plant. Simulations of linear system and model parameter identification is shown to converge to the predicted values of the model coefficients. The multivariable controller developed in this research could be designed in an algebraic fashion once the plant model is known. It is thus possible to implement the multivariable PI design in an adaptive fashion combining the controller with identified plant model on-line. This will result in a self-tuning regulator (STR) type controller where the underlying design criteria is the multivariable tuning technique designed in this research.

  16. Daylighting and Cooling of Atrium Buildings in Warm Climates: Impact of the Top-Fenestration and Wall Mass Area.

    Science.gov (United States)

    Atif, Morad Rachid

    1992-01-01

    Sun-lighting and daylighting contribute greatly to the aesthetic value of an atrium. However, today's atria are often found either over-lit with extensive cooling loads, or under-lit requiring increased artificial lighting loads. The increase of the top-glazing area increases the cooling loads and decreases the lighting loads. The increase of the mass in the atrium walls decreases the maximum atrium temperature and the cooling loads. Furthermore, the mass distribution and its reflectance affect the lighting levels at the atrium floor. The purpose of this study is to investigate the simultaneous impact of the top-fenestration and the mass and reflectance of atrium walls on the cooling and daylighting performance of atria in warm climates. It attempts to determine the optimum top-fenestration for efficient daylighting and low cooling loads. The daylighting performance was evaluated through illumination measurements in physical models in a sky simulator. The cooling performance was evaluated using the software TRNSYS 13.1. Two types of top-fenestration were tested: horizontal and vertical south-facing, each with three alternate areas. The variations of the atrium walls included materials (standard frame and heavyweight concrete) and percentage and reflectance of the solid area. Two and four-story atria were considered, each with square and linear configuration. The performance was evaluated for three warm climates. The optimum top-fenestration for efficient daylighting was determined. The daylighting prediction algorithm was extended to include the effective reflectance of the atrium walls. The increase of mass in the atrium walls significantly decreased the atrium temperature range, the maximum atrium temperature, and the cooling loads. This impact decreased from horizontal to vertical south-facing top-glazing. The vertical south-facing top-glazing and, to a lesser degree, the reduction of the glazed atrium cover by 50% had more cooling benefits than increasing the

  17. Analysis of Daylight Control in a Chateau Interior

    Directory of Open Access Journals (Sweden)

    Jitka Mohelníková

    2018-05-01

    Full Text Available Assessment of daylighting in the residential hall of a historical chateau is presented. The evaluation is based on both the daylight measurement and simulations. Illuminance levels in the interior were controlled in accordance with requirements for light exposition of light sensitive materials. Valuable paintings and claddings as well as wallpapers and furniture upholstery in the hall are extremely light sensitive and they need to be protected from light damage. The daylight measurements and simulations give an overview of daylight conditions in the annual profile for clear sky conditions and for different levels of window shadings.

  18. Literature Review of the Effects of Natural Light on Building Occupants

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, L.; Torcellini, P.

    2002-07-01

    This paper presents summary findings from a literature search of the term ''daylighting''-using natural light in a building to offset or replace electric lighting. According to the Department of Energy's Office of Building Technology, State and Community Programs 2000 BTS Core Databook, in 1998, commercial buildings consumed 32% of the total electricity in the United States, of which more than one-third went to lighting. Using daylighting systems and turning off the lights will help reduce this energy load. Electrical lighting adds to both the electrical and cooling loads in a commercial building. Utility costs can be decreased when daylighting is properly designed to replace electrical lighting. Along with the importance of energy savings, studies have demonstrated the non-energy-related benefits of daylighting. We compiled the data from books, periodicals, Internet articles, and interviews. The books, periodicals, and Internet articles provided the background information used to identify the main subjects of the paper. The interviews provided us with details related to specific buildings and companies that have integrated daylighting into their buildings.

  19. The New York Times headquarters daylighting mockup: Monitoredperformance of the daylighting control system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; Selkowitz, Stephen E.

    2006-02-24

    A nine-month monitored field study of the performance of automated roller shades and daylighting controls was conducted in a 401 m{sup 2} unoccupied, furnished daylighting mockup. The mockup mimicked the southwest corner of a new 110 km{sub 2} commercial building in New York, New York, where The New York Times will be the major tenant. This paper focuses on evaluating the performance of two daylighting control systems installed in separate areas of an open plan office with 1.2-m high workstation partitions: (1) Area A had 0-10 V dimmable ballasts with an open-loop proportional control system and an automated shade controlled to reduce window glare and increase daylight, and (2) Area B had digital addressable lighting interface (DALI) ballasts with a closed-loop integral reset control system and an automated shade controlled to block direct sun. Daylighting control system performance and lighting energy use were monitored. The daylighting control systems demonstrated very reliable performance after they were commissioned properly. Work plane illuminance levels were maintained above 90% of the maximum fluorescent illuminance level for 99.9{+-}0.5% and 97.9{+-}6.1% of the day on average over the monitored period, respectively, in Areas A and B. Daily lighting energy use savings were significant in both Areas over the equinox-to-equinox period compared to a non-daylit reference case. At 3.35 m from the window, 30% average savings were achieved with a sidelit west-facing condition in Area A while 50-60% were achieved with a bilateral daylit south-facing condition in Area B. At 4.57-9.14 m from the window, 5-10% and 25-40% savings were achieved in Areas A and B, respectively. Average savings for the 7-m deep dimming zone were 20-23% and 52-59% for Areas A and B, respectively, depending on the lighting schedule. The large savings and good reliability can be attributed to the automatic management of the interior shades. The DALI-based system exhibited faulty behavior that

  20. Estimation of exterior vertical daylight for the humid tropic of Kota Kinabalu city in East Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Djamila, Harimi; Ming, Chu Chi; Kumaresan, Sivakumar [School of Engineering and Information Technology, Universiti Malaysia Sabah, Locked Bag No. 2073, 88999 Kota Kinabalu, Sabah (Malaysia)

    2011-01-15

    In tropical regions natural daylight has been a fundamental factor in building design. It is the most efficient way of lighting a building in the daytime and has a great potential for energy conservation in buildings. In Malaysia there are a limited available data of measured illuminance which is the case of several regions in the tropics. Using established models it is possible to predict the luminous efficacy and then estimate the monthly mean hourly exterior illuminance. In this study two different models were chosen. The Perez and Du Mortier-Perraudeau-Page-Littlefair models were selected for the prediction of hourly exterior horizontal illuminance for the city of Kota Kinabalu in East Malaysia. Comparison between the two models were made. The vertical hourly illuminance was predicted also using Perez approach. The potentiality of daylight in four orientations was discussed. This study highlights the importance of Sunpath diagram on daylight illuminance during the conceptual design stage. The results in this study is hoped to contribute further insight into the potentiality of daylighting of tropical sky. (author)

  1. Fuzzy-Neural Automatic Daylight Control System

    Directory of Open Access Journals (Sweden)

    Grif H. Şt.

    2011-12-01

    Full Text Available The paper presents the design and the tuning of a CMAC controller (Cerebellar Model Articulation Controller implemented in an automatic daylight control application. After the tuning process of the controller, the authors studied the behavior of the automatic lighting control system (ALCS in the presence of luminance disturbances. The luminance disturbances were produced by the authors in night conditions and day conditions as well. During the night conditions, the luminance disturbances were produced by turning on and off a halogen desk lamp. During the day conditions the luminance disturbances were produced in two ways: by daylight contributions changes achieved by covering and uncovering a part of the office window and by turning on and off a halogen desk lamp. During the day conditions the luminance disturbances, produced by turning on and off the halogen lamp, have a smaller amplitude than those produced during the night conditions. The luminance disturbance during the night conditions was a helpful tool to select the proper values of the learning rate for CMAC controller. The luminance disturbances during the day conditions were a helpful tool to demonstrate the right setting of the CMAC controller.

  2. Electrical properties of conducting loads produced from polyaniline deposited in natural fibers and nanoclays

    International Nuclear Information System (INIS)

    Kosenhoski, Dirlaine; Saade, Wesley; Pinto, Camila P.; Becker, Daniela; Dalmolin, Carla; Pachekoski, Wagner M.

    2015-01-01

    Conducting polymers are known for their excellent magnetic and electrical properties, but they still are an expensive and limited choice to their use as a conducting load for composite materials. An alternative to optimize the electrical conductivity of polymeric composites is the deposition of a conducting polymer on materials already used as loads, as the deposition on natural fibers or the encapsulation of polymeric chains in the voids of host structures. In this work, bananastem fiber and montmorillonite nanoclay (MMT) were used as host structures for polyaniline synthesis in order to produce conducting loads. Samples were characterized by FT-IR and X-Rays Diffraction in order to confirm the formation of polyanilina / bananastem fibers or polyanilina / nanoclays loads. Influence on the electrical properties of the composites were evaluated by Electrochemical Impedance Spectroscopy (EIS), showing the maintenance of the electric conductivity of polyaniline and its potential use as a load for the formation of conducting composites. (author)

  3. Human genetics studies in areas of high natural radiation. VII. Genetic load

    Energy Technology Data Exchange (ETDEWEB)

    Freire-Maia, A [Faculdade de Ciencias Medicas e Biologicas de Botucatu (Brazil). Departamento de Genetica

    1975-01-01

    Two methods to estimate the inbreeding load, employed in our analysis, are reviewed. Besides the total population, a sample constituted of individuals with no alien ancesters is also analyzed. The measurements by genetic load models show a clear effect of natural radioactivity (especially for abortions, pre-natal mortality, anomalies, and abnormalities in general). The results on stillbirths and post-natal and total mortalities are discussed and it is concluded that uncontrolled concomitant variables (if not chance alone) cause the differences.

  4. Investigating the Influence of Light Shelf Geometry Parameters on Daylight Performance and Visual Comfort, a Case Study of Educational Space in Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Moazzeni

    2016-07-01

    Full Text Available Daylight can be considered as one of the most important principles of sustainable architecture. It is unfortunate that this is neglected by designers in Tehran, a city that benefits from a significant amount of daylight and many clear sunny days during the year. Using a daylight controller system increases space natural light quality and decreases building lighting consumption by 60%. It also affects building thermal behavior, because most of them operate as shading. The light shelf is one of the passive systems for controlling daylight, mostly used with shading and installed in the upper half of the windows above eye level. The influence of light shelf parameters, such as its dimensions, shelf rotation angle and orientation on daylight efficiency and visual comfort in educational spaces is investigated in this article. Daylight simulation software and annual analysis based on climate information during space occupation hours were used. The results show that light shelf dimensions, as well as different orientations, especially in southern part, are influential in the distribution of natural light and visual comfort. At the southern orientation, increased light shelf dimensions result in an increase of the area of the work plane with suitable daylight levels by 2%–40% and a significant decrease in disturbing and intolerable glare hours.

  5. Hardware-in-the-Loop Modeling and Simulation Methods for Daylight Systems in Buildings

    Science.gov (United States)

    Mead, Alex Robert

    This dissertation introduces hardware-in-the-loop modeling and simulation techniques to the daylighting community, with specific application to complex fenestration systems. No such application of this class of techniques, optimally combining mathematical-modeling and physical-modeling experimentation, is known to the author previously in the literature. Daylighting systems in buildings have a large impact on both the energy usage of a building as well as the occupant experience within a space. As such, a renewed interest has been placed on designing and constructing buildings with an emphasis on daylighting in recent times as part of the "green movement.''. Within daylighting systems, a specific subclass of building envelope is receiving much attention: complex fenestration systems (CFSs). CFSs are unique as compared to regular fenestration systems (e.g. glazing) in the regard that they allow for non-specular transmission of daylight into a space. This non-specular nature can be leveraged by designers to "optimize'' the times of the day and the days of the year that daylight enters a space. Examples of CFSs include: Venetian blinds, woven fabric shades, and prismatic window coatings. In order to leverage the non-specular transmission properties of CFSs, however, engineering analysis techniques capable of faithfully representing the physics of these systems are needed. Traditionally, the analysis techniques available to the daylighting community fall broadly into three classes: simplified techniques, mathematical-modeling and simulation, and physical-modeling and experimentation. Simplified techniques use "rules-of-thumb'' heuristics to provide insights for simple daylighting systems. Mathematical-modeling and simulation use complex numerical models to provide more detailed insights into system performance. Finally, physical-models can be instrumented and excited using artificial and natural light sources to provide performance insight into a daylighting system

  6. Integrated performance appraisal of Daylight-Europe case study buildings

    NARCIS (Netherlands)

    Hensen, J.L.M.; Clarke, J.A.; Hand, J.W.; Johnson, K.; Wittchen, K.; Madsen, C.; Compagnon, R.

    1996-01-01

    This paper describes the approach taken within the EC’s Daylight-Europe project to apply combined thermal/daylight simulations to existing building designs which are representative of European types and climate contexts. The outputs from the performance appraisals are then incorporated within design

  7. Effect of load carriage and natural terrain conditions on cognitive performance in desert environments.

    Science.gov (United States)

    Bhattacharyya, Debojyoti; Pal, Madhusudan; Chatterjee, Tirthankar; Majumdar, Dhurjati

    2017-10-01

    Correct decision making is a critical component of cognitive performance of a soldier, which may be influenced by the load carriage and terrain conditions during their deployment in desert environment. The present study was aimed to investigate the effects of loads and terrain conditions on the cognitive performance in a group of twelve healthy heat acclimatized infantry soldiers under natural desert environment. The soldiers participated in a 10min walking trial during carrying no load and also carrying 10.7, 21.4 and 30kg at two terrain conditions viz., sandy and hard. We studied attention, memory and executive function, which are having immense functional importance in military operations. Standardized cognitive test battery was applied to the participants after carrying each magnitude of load at each terrain. Baseline cognitive performance was recorded on a separate day and was compared with the performances recorded after the load carriage trials. An attempt was made to reveal the relationship between physiological workload (relative workload) and cognitive performance at the point of completion of load carriage trials. Load, terrains and load×terrain interaction did not produce any significant effect (p>0.05) on the cognitive performance. Attention and relative workload were found significantly correlated at hard terrain under no load, 21.4kg and 30kg. Significant correlation was found between executive function and relative workload at hard terrain under no load. Carrying upto 30kg load for 10min at 3.5-4kmph walking speed resulted in improvement in attention at sandy terrain, decrement in memory at both sandy and hard terrains and improvement in executive function at sandy terrain. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Application and Computer Analysis of Solar Systems for the Indoor Daylighting

    Energy Technology Data Exchange (ETDEWEB)

    Makhmudov, Is Kandar

    2010-02-15

    A steady increase of energy costs and ever growing environmental concerns in recent years have forced scientists to look for new methods of energy utilization. To resolve these dire problems, the application of renewable energy sources has been considered in various human activities in every sector of society. One of them is the development of solar daylighting systems for residential and commercial buildings, which can improve building energy efficiency and create comfortable indoor environment. Electric lighting represents up to 30 % of building electricity consumption. Therefore, using sunlight in indoor daylighting can significantly reduce electricity consumption in residential and commercial buildings. Moreover, daylight is an important factor in visual environment and improving human well-being. In last decades, different approaches to the design of solar daylighting systems have resulted in various innovative solutions to efficiently introduce natural light in buildings. But their efficiency and cost are still one of primary obstacles in the wider development and distribution of solar daylighting systems. In this study, we investigated the performance of a new solar concentrator system for indoor illumination. The solar concentrator system consists of 30 cm dish concentrators, high precision solar trackers, optical fibers and diffusers for a light distribution. In order to assess the daylighting system's efficiency, there were carried out several experimental measurement series. One of them was an application of our solar daylighting system to two standard classrooms with south- and north-oriented windows in Jeju city, Korea. At the same time classrooms were modeled by using ECOTECT and exported to RADIANCE for daylighting simulations. Results from the measurements and simulations were analyzed comprehensively to establish the reliability of the modeling process. Following this, we modeled both classrooms with the above mentioned daylighting systems

  9. EFICIENCIA ENERGÉTICA POR LA UTILIZACIÓN DE COMPONENTES DE CONDUCCIÓN DE LUZ NATURAL EN CLIMA CÁLIDO-HÚMEDO | ENERGETIC EFFICIENCY DERIVED FROM THE USE OF CONDUCTION COMPONENTS OF DAYLIGHT IN WARM-HUMID CLIMATE

    Directory of Open Access Journals (Sweden)

    Rosalinda González Gómez

    2015-11-01

    Full Text Available The electric energy saving was estimated by the utilization of Conduction Components of Daylight (CCD in warm-humid climate. For this, the luminic performance of the component was determined, considering values of horizontal exterior lighting and interior lighting obtained by monitoring under real sky conditions in scale models, and the comparison with incandescent bulbs and Compact Fluorescent Lamps (CFL. The utilization of the natural light through CCLN allows to obtain a saving in the expense for energy, with respect to the use of Incandescent Bulb and/or Compact Fluorescent Lamp (artificial lighting. In this sense, their use would correspond to 219 KWh and to 54.75 KWh, respectively, if they are used for an average of 10 daily hours, during a period of one year. It was estimated that a possible reduction could be achieved in the electricity consumption, maintaining the comfort and quality of life of the users in buildings (high luminic performance without use of energy from commercial supplier, contributing this way to the "energy efficiency" in them.

  10. Analysis and prediction of daylighting and energy performance in atrium spaces using daylight-linked lighting controls

    International Nuclear Information System (INIS)

    Chow, Stanley K.H.; Li, Danny H.W.; Lee, Eric W.M.; Lam, Joseph C.

    2013-01-01

    Highlights: ► Daylight-linked lighting control and energy performance for atrium is studied. ► Field measurement of automatic dimming control shows 93% energy saving. ► Field measurement of manual on–off control shows 95% energy saving. ► Atrium illuminance is correlated with daylight factor for energy saving prediction. - Abstract: In subtropical Hong Kong, a certain amount of electricity is used to create visually comfortable interior spaces through electric lighting, which is the second major electricity-consuming item in commercial buildings, accounting for 20–30% of total electricity use. The burning of fossil fuels for electricity generation has many adverse effects on the environment. Daylighting is an important and useful strategy for enhancing visual comfort and reducing the need for the electricity consumed by light fittings. The rational use of daylight through tools such as photoelectric lighting controls can effectively reduce buildings’ electricity consumption and the related pollutants and greenhouse gas emissions. Daylighting design techniques are often best demonstrated via field measurements that provide reliable operational and energy performance data for establishing design guidelines. An atrium provides an environmentally controlled indoor public space that introduces daylight into the hearts of large buildings. In circulation areas such as corridors, people expect the way ahead to be sufficiently lit and daylight-linked lighting controls can deliver excellent energy savings. This paper presents the daylighting and energy performance of an atrium space using daylight-linked lighting controls. The cost, energy and environmental issues related to various daylight illuminances are estimated and design implications are discussed

  11. Daylight Management in Mediterranean Cities: When Shortage Is Not the Issue

    OpenAIRE

    Judit Lopez-Besora; Glòria Serra-Coch; Helena Coch; Antonio Isalgue

    2016-01-01

    Natural resources such as daylight and sunlight are highly appreciated in countries with prevailing overcast skies. Taking advantage of this scarce resource contributes to saving energy on artificial lighting. In contrast to northern, southern European cities are distinguished by a large number of days with direct sunlight caused by a propitious climate condition. While it is a positive issue in terms of energy availability, the abundance of it can be counterproductive if management measures ...

  12. Daylight and energy implications for CIE standard skies

    International Nuclear Information System (INIS)

    Li, Danny H.W.

    2007-01-01

    Recently, the International Commission on Illumination (CIE) has adopted a range of 15 standard skies, which include the existing CIE overcast, very clear and cloudless polluted skies, covering the whole probable spectrum of usual skies found in the world. The traditional daylight factor (DF) approach with the calculations being based on an isotropic overcast sky, however, cannot cater to the dynamic variations in daylight luminance and illuminance as the sun's position changes under non-overcast skies. Currently, we propose a numerical procedure that considers the changes in the luminance of sky elements to predict the interior daylight illuminance under the 15 CIE standard skies. This paper evaluates the method by using a typical room with a large vertical glazing window facing north. The available daylight for the room at mean hourly sun positions in each month in terms of DF and illuminance levels were determined and compared with those based on a computer program, namely, RADIANCE. A modification to the ground reflected component was made when a well defined shadow was cast in front of the window facade. It is shown that the results estimated by the proposed approach are in reasonably good agreement with those produced from RADIANCE. The interior daylight and lighting energy consumption were also determined using the proposed and the traditional DF approaches. The findings reveal that daylighting designs using existing CIE overcast sky only would considerably underestimate the indoor daylight availability and electric lighting energy savings, especially under high design indoor illuminance settings

  13. STUDI SIMULASI MODEL PENERANGAN ALAMI (DAYLIGHTING RUANG PADA BANGUNAN FASILITAS PENDIDIKAN TINGGI DENGAN SUPERLITE 2.0

    Directory of Open Access Journals (Sweden)

    Hanni Elitasari Mahaputri

    2012-08-01

    Full Text Available Daylight was the only efficient source of light available for building. Therefore, architecture was dominated by the goal of creating openings large enough to distribute daylight to building interiors. It is important to understand the amount of natural light penetration when outdoor obstruction are displaced in order to propose optimum external shading strategies as design solutions. This paper presents a study of the daylight factor and daylight contourt approaches and also investigates the effect of outdoor obstruction displacement on natural-light penetration of a specific room in higher-education building facility. The interior daylight illuminance data were simulated and analyzed using Superlite 2.0. The result shows that several effects of the external obstruction displacement as shading provider, depending on transmitted natural-light penetration, which determine the better consideration option in designing landscape surround building, especially in hot humid climates. Sinar matahari merupakan sumber penerangan yang efisien bagi bangunan. Tujuan utama dalam arsitektur adalah merancang bukaan pencahayaan yang cukup besar bagi bangunan untuk mendistribusikan cahaya ke bagian dalam bangunan. Sangat penting untuk mengetahui besar penetrasi penerangan alami yang masuk ke dalam ruang bila di luar bangunan diletakkan suatu halangan sebagai salah satu solusi disain dengan mengoptimalkan strategi perancangan pem­bayangan lingkungan. Makalah ini membahas tentang kajian pendekatan faktor penerangan alami (daylight factor dan koefisien penerangan alami, serta mengamati pengaruh perletakan halangan lingkungan terhadap penetrasi penerangan alami suatu ruang fasilitas pendidikan tinggi. Data illuminasi penerangan interior disimulasikan dan dianalisa menggunakan software Superlite 2.0. Hasil penelitian menunjukkan beberapa pengaruh perletakan halangan lingkungan sebagai elemen pembayangan lingkungan berkaitan dengan penetrasi cahaya alami, yang

  14. Stress distribution and displacement of abutment of middle implant-natural teeth fixed bridge under different loading

    International Nuclear Information System (INIS)

    Chen Erjun; Zhou Yanmin; Ma Chenchun; Cong Zhiqiang; Jiang Yonghua

    2004-01-01

    Objective: To study stress distribution and displacement of abutment of middle implant-natural teeth fixed bridge under different loading. Methods: The stress distribution and displacement of abutment were studied and analyzed by means of three-dimensional finite element when different loading was applied. Results: The biggest stress of middle implant was 4-5 times as big as that of natural teeth. Under concentrated vertical loading, the biggest stress of implant was about 2 times higher than that under dispersed vertical loading. There was no significant difference of biggest stress on the implant between concentrated oblique loading and dispersed oblique loading. The biggest stress of implant under oblique loading was 3 times as big as that under dispersed vertical loading. The biggest stress of natural teeth under dispersed loading was lower than that under concentrated loading. The maximum displacement of implant in occlusal-gum direction was great lower than that of natural teeth. Both in buccal-lingual direction and medial-distal direction, the displacement of implant were about equal to that of natural teeth. Conclusion: The oblique loading is the main force to destroy the middle implant-natural teeth fixed bridge. The lean of cusp should be reduced. The abnormally high occlusal points should be deleted. The bite points should be well distributed. The fixed bridge is feasible. (authors)

  15. Effects of daylight savings time changes on stock market volatility.

    Science.gov (United States)

    Berument, M Hakan; Dogan, Nukhet; Onar, Bahar

    2010-04-01

    The presence of daylight savings time effects on stock returns and on stock volatility was investigated using an EGARCH specification to model the conditional variance. The evidence gathered from the major United States stock markets for the period between 1967 and 2007 did not support the existence of the daylight savings time effect on stock returns or on volatility. Returns on the first business day following daylight savings time changes were not lower nor was the volatility higher, as would be expected if there were an effect.

  16. Effect of Ingredient Loading on Surface Migration Kinetics of Additives in Vulcanized Natural Rubber Compounds

    Directory of Open Access Journals (Sweden)

    Bryan B. Pajarito

    2014-12-01

    Full Text Available Surface migration kinetics of chemical additives in vulcanized natural rubber compounds were studied as function of ingredient loading. Rubber sheets were compounded according to a 212-8 fractional factorial design of experiment, where ingredients were treated as factors varied at two levels of loading. Amount of migrated additives in surface of rubber sheets was monitored through time at ambient conditions. The maximum amount and estimated rate of additive migration were determined from weight loss kinetic curves. Attenuated total reflection–Fourier transform infrared (ATR-FTIR spectroscopy and optical microscopy were used to characterize the chemical structure and surface morphology of sheet specimens during additive migration. ANOVA results showed that increased loading of reclaimed rubber, CaCO3, and paraffin wax signif icantly decreased the maximum amount of additive migration; by contrast, increased loading of used oil, asphalt, and mercaptobenzothiazole disulphide (MBTS increased the maximum amount. Increased loading of sulfur, diphenylguanidine (DPG, and paraffin wax significantly decreased the additive migration rate; increased loading of used oil, asphalt, and stearic acid elicited an opposite effect. Comparison of ATRFTIR spectra of migrated and cleaned rubber surfaces showed signif icant variation in intensity of specif ic absorbance bands that are also present in infrared spectra of migrating chemicals. Paraffin wax, used oil, stearic acid, MBTS, asphalt, and zinc stearate were identified to bloom and bleed in the rubber sheets. Optical micrographs of migrated rubber surfaces revealed formation of white precipitates due to blooming and of semi-transparent wet patches due to bleeding.

  17. The impact on energy consumption of daylight saving clock changes

    Energy Technology Data Exchange (ETDEWEB)

    Hill, S.I.; Desobry, F. [Department of Engineering, University of Cambridge (United Kingdom); Garnsey, E.W. [Institute for Manufacturing, University of Cambridge (United Kingdom); Chong, Y.-F. [IPA Energy and Water Consulting (United Kingdom)

    2010-09-15

    The focus of this work is an investigation of the effect of prevailing time regime on energy consumption. In particular we perform analysis demonstrating potential energy savings which could be obtained were Great Britain to maintain daylight savings time (DST) over winter, instead of reverting to Greenwich mean time (GMT). We review the literature on the effect of DST on energy consumption and show that this indicates a justification for considering the issue. Our headline result is in agreement with many related studies in that advancing the clock by an hour in winter would lead to energy savings of at least 0.3% of daily demand in Great Britain. In deriving this result we have adopted methodologies currently used in load prediction, in particular Support Vector Regression, to estimate energy demand on a half-hourly basis. Corresponding cost savings are found to be higher (due to the nonlinear increase of costs) and we find them to be on the order of 0.6% over the months considered. In terms of environmental impact we find the saving to be approximately equivalent to 450,000 ton of CO{sub 2}. In deriving these results we adopt a conservative approach such that we consider them lower bounds on any true savings. (author)

  18. The impact on energy consumption of daylight saving clock changes

    International Nuclear Information System (INIS)

    Hill, S.I.; Desobry, F.; Garnsey, E.W.; Chong, Y.-F.

    2010-01-01

    The focus of this work is an investigation of the effect of prevailing time regime on energy consumption. In particular we perform analysis demonstrating potential energy savings which could be obtained were Great Britain to maintain daylight savings time (DST) over winter, instead of reverting to Greenwich mean time (GMT). We review the literature on the effect of DST on energy consumption and show that this indicates a justification for considering the issue. Our headline result is in agreement with many related studies in that advancing the clock by an hour in winter would lead to energy savings of at least 0.3% of daily demand in Great Britain. In deriving this result we have adopted methodologies currently used in load prediction, in particular Support Vector Regression, to estimate energy demand on a half-hourly basis. Corresponding cost savings are found to be higher (due to the nonlinear increase of costs) and we find them to be on the order of 0.6% over the months considered. In terms of environmental impact we find the saving to be approximately equivalent to 450,000 ton of CO 2 . In deriving these results we adopt a conservative approach such that we consider them lower bounds on any true savings.

  19. Daylighting for energy conservation in an existing building under tropical climate conditions: a case study of Lai Sue Thai building Ramkhamhaeng University

    Directory of Open Access Journals (Sweden)

    Lerdlekha Tanachaikhan

    2015-12-01

    Full Text Available Daylighting using skylight has been shown to have a high potential in reducing electrical lighting energy, and could provide a more pleasant atmosphere of a daylit space. However, in hot climates, the main constraint of daylighting is the solar heat gain that contributes to major heat load for an air-conditioning system. If the balance between the beneficial light gain used to offset lighting energy requirement and heat gain from daylight is well considered, significant energy savings can be obtained. The main objective of the study is to evaluate the potential of daylighting for energy conservation in the tropics through theoretical analysis (simulation study and experimental observation. Lai Sue Thai Building (an existing and educational building located at Ramkhamkaeng University was selected as a case study. From analysis, use of daylight could reduce electrical energy in this building by up to 76% compared to the initial condition where fully lighting was supplied. Window orientation would also play an important role. Moreover, heat gain through windows due to daylighting can be controlled by overhangs and the appropriate Window-to-Wall ratio that would be about 30% for this building. An experimental study was also carried out to validate the results in a selected room. About 49% and 37% of Relative Root Mean Square Error (RRMSE were observed in light and heat measurements, respectively

  20. External perforated Solar Screens for daylighting in residential desert buildings: Identification of minimum perforation percentages

    KAUST Repository

    Sherif, Ahmed

    2012-06-01

    The desert climate is endowed by clear sky conditions, providing an excellent opportunity for optimum utilization of natural light in daylighting building indoor spaces. However, the sunny conditions of the desert skies, in countries like Egypt and Saudi Arabia, result in the admittance of direct solar radiation, which leads to thermal discomfort and the incidence of undesired glare. One type of shading systems that is used to permit daylight while controlling solar penetration is " Solar Screens" Very little research work addressed different design aspects of external Solar Screens and their influence on daylighting performance, especially in desert conditions, although these screens proved their effectiveness in controlling solar radiation in traditional buildings throughout history.This paper reports on the outcomes of an investigation that studied the influence of perforation percentage of Solar Screens on daylighting performance in a typical residential living room of a building in a desert location. The objective was to identify minimum perforation percentage of screen openings that provides adequate illuminance levels in design-specific cases and all-year-round.Research work was divided into three stages. Stage one focused on the analysis of daylighting illuminance levels in specific dates and times, while the second stage was built on the results of the first stage, and addressed year round performance using Dynamic Daylight Performance Metrics (DDPMs). The third stage addressed the possibility of incidence of glare in specific cases where illuminance levels where found very high in some specific points during the analysis of first stage. The research examined the daylighting performance in an indoor space with a number of assumed fixed experimentation parameters that were chosen to represent the principal features of a typical residential living room located in a desert environment setting.Stage one experiments demonstrated that the screens fulfilled the

  1. effect of daylight hours on performance of growing grasscutters

    African Journals Online (AJOL)

    user

    DNA.Many animals use the daily variation in the duration and quantity of melatonin ... such as reproduction, behavior, coat growth and ... behavioral processes in the biological system. The ... spends the daylight hours sleeping or resting. The.

  2. Teaching Science: Beats the Daylight Out of Me.

    Science.gov (United States)

    Leyden, Michael B.

    1995-01-01

    Presents activities for observing, measuring, collecting, and graphing data about times of sunrise and sunset to teach an understanding about arrival of Daylight Savings Time in April. Also discusses seasonal affective disorder (SAD). (TM)

  3. Energy-efficient window systems. Effects on energy use and daylight in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Buelow-Huebe, H.

    2001-11-01

    This thesis deals with energy-efficient windows in Swedish buildings. Parametric studies were performed in the dynamic energy simulation tool Derob-LTH in order to study the effects of window choices on energy use and indoor climate for both residential and office buildings. A steady-state program was used to evaluate two years of measurements of energy use and indoor temperatures of an energy-efficient row-house. Two behavioural studies regarding (1) daylight transmittance, view and room perception using super-insulated windows and (2) the satisfaction with the daylight environment and the use of shading devices in response to daylight/sunlight were conducted in full-scale laboratory environments exposed to the natural climate. Results show that as the energy-efficiency of buildings increase, window U-values must decrease in order not to increase the annual heating demand, since the heating season is shortened, and useful solar gains become smaller. For single-family houses with a window-to-floor area ratio of 15 % and insulated according the current Swedish building code, the U-values should thus on average be lower than 1.0 W/m{sup 2}K. For houses insulated according to 1960s standard, the U-value may on average be 1.6 W/m{sup 2}K. For colder climates (northern Sweden), the U-values should be somewhat lower, while slightly higher U-values can be tolerated in milder climates of south Sweden. Thermal comfort during winter is improved for energy-efficient windows. However, overheating problems exist for both super-insulated houses and highly glazed office buildings showing a need for very low U-values in combination with low g-values. Daylight experiments indicate that the use of two low-emittance coatings tints the transmitted daylight enough to be appreciated, and colours may be perceived as more drab and rooms more enclosed. A compromise between energy-efficiency and daylighting may be needed, and it is suggested that only one coating be used except when very

  4. Daylight savings time and myocardial infarction.

    Science.gov (United States)

    Sandhu, Amneet; Seth, Milan; Gurm, Hitinder S

    2014-01-01

    Prior research has shown a transient increase in the incidence of acute myocardial infarction (AMI) after daylight savings time (DST) in the spring as well as a decrease in AMI after returning to standard time in the fall. These findings have not been verified in a broader population and if extant, may have significant public health and policy implications. We assessed changes in admissions for AMI undergoing percutaneous coronary intervention (PCI) in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) database for the weeks following the four spring and three fall DST changes between March 2010 and September 2013. A negative binomial regression model was used to adjust for trend and seasonal variation. There was no difference in the total weekly number of PCIs performed for AMI for either the fall or spring time changes in the time period analysed. After adjustment for trend and seasonal effects, the Monday following spring time changes was associated with a 24% increase in daily AMI counts (p=0.011), and the Tuesday following fall changes was conversely associated with a 21% reduction (p=0.044). No other weekdays in the weeks following DST changes demonstrated significant associations. In the week following the seasonal time change, DST impacts the timing of presentations for AMI but does not influence the overall incidence of this disease.

  5. The Impact of Roof Pitch and Ceiling Insulation on Cooling Load of Naturally-Ventilated Attics

    Directory of Open Access Journals (Sweden)

    Linxia Gu

    2012-07-01

    Full Text Available A 2D unsteady computational fluid dynamics (CFD model is employed to simulate buoyancy-driven turbulent ventilation in attics with different pitch values and ceiling insulation levels under summer conditions. The impacts of roof pitch and ceiling insulation on the cooling load of gable-roof residential buildings are investigated based on the simulation of turbulent air flow and natural convection heat transfer in attic spaces with roof pitches from 3/12 to 18/12 combined with ceiling insulation levels from R-1.2 to R-40. The modeling results show that the air flows in the attics are steady and exhibit a general streamline pattern that is qualitatively insensitive to the investigated variations of roof pitch and ceiling insulation. Furthermore, it is predicted that the ceiling insulation plays a control role on the attic cooling load and that an increase of roof pitch from 3/12 to 8/12 results in a decrease in the cooling load by around 9% in the investigated cases. The results suggest that the increase of roof pitch alone, without changing other design parameters, has limited impact on attics cooling load and airflow pattern. The research results also suggest both the predicted ventilating mass flow rate and attic cooling load can be satisfactorily correlated by simple relationships in terms of appropriately defined Rayleigh and Nusselt numbers.

  6. Effect of natural ageing on surface of silver loaded TPE and its influence in antimicrobial efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Tomacheski, Daiane, E-mail: daitomacheski@gmail.com [Department of Materials Engineering, Laboratory of Polymers – LAPOL, Universidade Federal do Rio Grande do Sul, UFRGS, 9500 Bento Gonçalves Avenue, Postal Code 15010, Porto Alegre 91501-970 (Brazil); Softer Brasil Compostos Termoplásticos LTDA, 275 Edgar Hoffmeister Avenue, Campo Bom 93700-000 (Brazil); Pittol, Michele [Softer Brasil Compostos Termoplásticos LTDA, 275 Edgar Hoffmeister Avenue, Campo Bom 93700-000 (Brazil); Simões, Douglas Naue; Ribeiro, Vanda Ferreira [Department of Materials Engineering, Laboratory of Polymers – LAPOL, Universidade Federal do Rio Grande do Sul, UFRGS, 9500 Bento Gonçalves Avenue, Postal Code 15010, Porto Alegre 91501-970 (Brazil); Softer Brasil Compostos Termoplásticos LTDA, 275 Edgar Hoffmeister Avenue, Campo Bom 93700-000 (Brazil); Santana, Ruth Marlene Campomanes [Department of Materials Engineering, Laboratory of Polymers – LAPOL, Universidade Federal do Rio Grande do Sul, UFRGS, 9500 Bento Gonçalves Avenue, Postal Code 15010, Porto Alegre 91501-970 (Brazil)

    2017-05-31

    Highlights: • Ag loaded TPE lost their antimicrobial efficacy after polymer degradation. • Modifications in Ag loaded TPE surface provide conditions to bacteria settlement. • Rough TPE surface and the low γ{sub S}{sup +} was more favorable for bacterial development. - Abstract: The aim of this study is to characterize the modifications in silver loaded TPE surfaces exposed to weathering and their relation to susceptibility to microbial attack. Silver loaded TPE materials were exposed to natural ageing for nine months and modifications in antimicrobial properties and surface characteristics were evaluated. Chemical changes were investigated by using the infrared spectra. The average surface roughness and topography were determined by atomic force microscopy. Contact angle was measured to verify wettability conditions and surface free energy (SFE). After nine months of exposure, a decrease in the antimicrobial properties of loaded TPE compounds was observed. A reduction in surface roughness and improvement in wettability and high values of polar component of SFE were verified. The best antibacterial action was noticed in the sample with high Lewis acid force, lower roughness and lower carbonyl index.

  7. Daylighting Design in Classroom Based on Yearly-Graphic Analysis

    Directory of Open Access Journals (Sweden)

    Yang Guan

    2016-07-01

    Full Text Available In China, existing buildings comprise more than 40 billion square meters, most being of high energy consumption. A substantial reduction in electrical energy costs could be obtained through greater use of daylight. Daylight varies widely due to the movement of sun, changing seasons and diverse weather conditions. Custom static daylight assessments, simulations represent only one time of the year or one time of the day, are inadequate to evaluate the dynamics of daylight variability. Using the intuitive graphic tool Temporal Map to display the annual daylight data, this study compared different passive architectural design strategies under the climate conditions of five representative Chinese cities and selected the most suitable design scheme for each city. In this study, the dynamic yearly-graphic tool was utilized for architectural design in China, and we integrated the optimal design with the Chinese academic calendar to achieve improvements within the occupancy time. This modified map connects design work with human activity that makes daylight evaluation more accurate and efficient. The results of this study will provide preliminary recommendations for energy-saving design in China, and reference to other similar studies.

  8. Light and architecture. Daylight - artificial light - energy; Licht und Architektur. Tageslicht - Kunstlicht - Energie

    Energy Technology Data Exchange (ETDEWEB)

    Wambsganss, M. (ed.) [ip5 ingenieurpartnerschaft, Karlsruhe (Germany)]|[Fachhochschule Rosenheim (Germany)

    2007-07-01

    The symposium intends to provide scientific and technical fundamentals for room lighting with daylight. Daylight deflection systems and artificial light control systems were analyzed for this purpose, and a catalogue of criteria was established. Planners were given tools for projecting daylight control systems. Builder-owners received the fundamentals for economic assessment of combined daylight and artificial light illumination systems, while industrial producers obtained information for further development to maturity and for marketing of daylight-dependent artificial light control systems. (GL)

  9. Light + architecture. Daylight - artificial light - energy; Licht + Architektur. Tageslicht - Kunstlicht - Energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    The symposium intends to provide scientific and technical fundamentals for room lighting with daylight. Daylight deflection systems and artificial light control systems were analyzed for this purpose, and a catalogue of criteria was established. Planners were given tools for projecting daylight control systems. Builder-owners received the fundamentals for economic assessment of combined daylight and artificial light illumination systems, while industrial producers obtained information for further development to maturity and for marketing of daylight-dependent artificial light control systems. (GL)

  10. Use of Daylight and Aesthetic Image of Glass Facades in Contemporary Buildings

    Science.gov (United States)

    Roginska-Niesluchowska, Malgorzata

    2017-10-01

    The paper deals with the architecture of contemporary buildings in respect to their aesthetic image created by the use of natural light. Sustainability is regarded as a governing principle of contemporary architecture, where daylighting is an important factor as it affects energy consumption and environmental quality of the space inside a building. Environmental awareness of architecture, however, involves a much wider and more holistic view of design. The quality of sustainable architecture can be considered in its aesthetic and cultural context with regard to landscape, local tradition, and connection to the surrounding world. This approach is associated with the social mission of architecture, i.e. providing appropriate space for living, facilitating social relations and having positive impact on people. The purpose of the research is to study the use of daylight in creating an aesthetic image of contemporary buildings. The author focuses mainly on public buildings largely dedicated to art and culture which satisfy high functional and aesthetic requirements. The paper examines the genesis and current trends in the aesthetic image of modern buildings which use daylight as the main design strategy, focusing on the issues of glass facades. The main attention is given to the shaping of representative public areas which feature the glass facades. The research has been based on a case study, critical review of literature review, observation and synthesis. The study identifies and classifies different approaches to using daylight in these areas and highlights changes in the aesthetics of architecture made of glass, which uses daylight as the main design strategy. These changes are primarily caused by the development and spreading of new glazing materials and the use of digital method of design. The influence of light and its mode depends on glass materials but also on the local conditions of the site, and has a significant impact on the relationship between

  11. Making daylighting work. Learning from failures to improve the design and implementation process

    Energy Technology Data Exchange (ETDEWEB)

    Vaidya, Prasad; McDougall, Tom; Steinbock, Jason; Douglas, James; Eijadi, David [The Weidt Group, Berkeley, CA (United States)

    2005-07-01

    Daylighting, hailed as a cornerstone of sustainable building design, is the primary passive solar design strategy in commercial buildings. It has the potential to significantly reduce lighting energy, which can be 40% or more of the energy cost of a commercial building. We have found that projects with daylighting often do not provide the expected energy savings. In a risk-averse construction industry, even limited failures can dramatically slow the advance of valid technologies. There are numerous reasons for failure: natural light sources are complex and vary through the day and year; implementation requires coordination between different building design and construction trades; the documentation and specification of the controls equipment is often inadequate; and calibration after installation is rarely done well and can be confusing and time consuming. In this paper, we provide four case studies as representative examples where daylighting did not deliver the expected energy savings. We identify the primary modes of failure and provide a template for each mode for easier problem resolution in the future. Through a detailed analysis of the case studies, we identify problem areas in the design and implementation process; we propose a more generalized solution set for design steps, documentation requirements and implementation checks that increase the chances of success.

  12. Daylighting and energy performance of a building for composite climate: An experimental study

    Directory of Open Access Journals (Sweden)

    Madhu Sudan

    2016-12-01

    Full Text Available The present study includes overall energy saving through thermal as well as daylighting for composite climate for the building known as SODHA BERS COMPLEX (SBC situated at Varanasi, India. The building has been designed including all the passive concepts for thermal comfort as well daylighting to maximize the use of natural lighting for the occupants in day to day activities. This approach can be useful for multi-story building for rural and urban areas for both residential and commercial buildings. The energy saving potential and corresponding CO2 mitigation have been determined for different lifetimes of the building. The energy matrices namely energy payback time (EPBT, energy production factor (EPF and life cycle conversion efficiency (LCCE of the building have also been estimated by considering overall energy saving. An annual energy saving has been obtained as 3675.61 kW h due to daylight concept by considering different Zones in each floors of the building. Further, the EPBT has been determined as 49.25 years and 34.73 years for average 4 °C and 6 °C temperature difference between ambient and room, respectively. It has been found that when thermal heat gain increases in the building LCCE and EPF increase.

  13. Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.

    Science.gov (United States)

    Pawaskar, Sainath Shrikant; Ingham, Eileen; Fisher, John; Jin, Zhongmin

    2011-01-01

    The articular cartilage covering the ends of the bones of diarthrodial synovial joints is thought to have evolved so that the loads are transferred under different and complex conditions, with a very high degree of efficiency and without compromising the structural integrity of the tissue for the life of an individual. These loading conditions stem from different activities such as walking, and standing. The integrity of cartilage may however become compromised due to congenital disease, arthritis or trauma. Hemiarthroplasty is a potentially conservative treatment when only the femoral cartilage is affected as in case of femoral neck fractures. In hemiarthroplasty, a metallic femoral prosthesis is used to articulate against the natural acetabular cartilage. It has also been hypothesized that biphasic lubrication is the predominant mechanism protecting the cartilage through a very high fluid load support which lowers friction. This may be altered due to hemiarthroplasty and have a direct effect on the frictional shear stresses and potentially cartilage degradation and wear. This study modelled nine activities of daily living and investigated the contact mechanics of a hip joint with a hemiarthroplasty, focussing particularly on the role of the fluid phase. It was shown that in most of the activities studied the peak contact stresses and peak fluid pressures were in the superior dome or lateral roof of the acetabulum. Total fluid load support was very high (~90%) in most of the activities which would shield the solid phase from being subjected to very high contact stresses. This was dependent not only on the load magnitude but also the direction and hence on the location of the contact area with respect to the cartilage coverage. Lower fluid load support was found when the contact area was nearer the edges where the fluid drained easily. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    International Nuclear Information System (INIS)

    Freiesleben, Trine; Sohbati, Reza; Murray, Andrew; Jain, Mayank; Al Khasawneh, Sahar; Hvidt, Søren; Jakobsen, Bo

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescence–depth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated luminescence-depth profile from a feldspar-rich granite cobble from an archaeological site near Aarhus, Denmark. This profile shows qualitative evidence for multiple daylight exposure and burial events; these are quantified using the model developed here. By determining the burial ages from the surface layer of the cobble and by fitting the new model to the luminescence profile, it is concluded that the cobble was well bleached before burial. This indicates that the OSL burial age is likely to be reliable. In addition, a recent known exposure event provides an approximate calibration for older daylight exposure events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible to determine the length of a fossil exposure, using a known natural light exposure as calibration. - Highlights: • Evidence for multiple exposure and burial events in the history of a single cobble. • OSL rock surface dating model improved to include multiple burial/exposure cycles. • Application of the new model quantifies burial and exposure events.

  15. Lighting control and dimensioning in integrated daylight systems

    Energy Technology Data Exchange (ETDEWEB)

    Halonen, L.; Eloholma, M.; Lehtovaara, J.

    1996-12-31

    The objective of this research was to find out the subjective and individual requirements for lighting control in connection with daylight utilization in indoor lighting. There is a great potential to use daylight in indoor lighting. This sets demands for the integrated daylight control systems, so that the indoor lighting can be optimized and demands of the users can be fulfilled. Control strategies should also take into account individual light needs, luminance balance and visual comfort. New lighting control systems and strategies such as vertical/horizontal illuminance ratio were studied. The incoming daylight may radically change the luminance distribution of the visual field and the effects of daylight on luminances of vertical surfaces may become especially noticeable. When daylight is utilized in indoor lighting, special care has to be taken to maintain the quality of the lighting of the visual environment. The windows become a potential source of discomfort glare in offices in uncontrolled daylight conditions. With the present methods it is not possible to evaluate discomfort glare caused by high surface luminances or windows. The results of this research do not support the opinion that low vision people in offices need more light than the normally sighted or that the illumination levels should be raised for low vision people. The rise of lighting levels from the present practice (task illuminance level 500 lux) in office work does not improve the visual performance of low vision people. In planning the visual environment for the low vision people care has to be taken on the direction of light. (7 refs.)

  16. IMPACT OF SIPHONING ACTIVITY AND NATURALLY SUSPENDED PARTICLE LOAD ON MUSSEL KILL by PSEUDOMONAS FLUORESCENS

    International Nuclear Information System (INIS)

    Daniel Molloy

    2003-01-01

    Under this USDOE-NETL contract, the bacterium Pseudomonas fluorescens is being developed as a biocontrol agent for zebra mussels. The specific purpose of the contract is to identify biotic and abiotic factors that affect mussel kill. Ingestion of these bacteria by zebra mussels is required to achieve kill, and tests evaluating factors that relate to mussel feeding are contained in this report. Specifically the impact of the following two factors were investigated: (1) Mussel siphoning behavior--In nature, zebra mussels typically have their two shells spread apart and their inhalant siphon tube extended from between their shells for taking food particles into their mantle cavities (Fig. 1). Our tests indicated that there is a direct correlation between mussel siphoning activity and mussel mortality achieved by a bacterial treatment. Therefore, to encourage mussel feeding on bacteria, future pipe treatments within power plants should be carried out using procedures which minimize disturbance to mussel siphoning. 2. Naturally suspended particle loads--Since bacterial cells are lethal only if ingested by mussels, waters containing very high levels of naturally suspended particles might reduce the mortality that can be achieved by a bacterial treatment. If true, this inhibition might occur as a result of particle exclusion, i.e., there could be reduced ingestion of bacterial cells since they represent a reduced percentage of all particles ingested. Our tests indicated that a range of particle concentrations that might naturally exist in a turbid river did not inhibit mussel kill by the bacterial cells, but that an artificially high load of natural particles was capable of causing a reduction in kill. To be conservative, therefore, future pipe treatments should be timed to occur when intake waters have relatively low quantities of naturally suspended particulate matter

  17. IMPACT OF SIPHONING ACTIVITY AND NATURALLY SUSPENDED PARTICLE LOAD ON MUSSEL KILL by PSEUDOMONAS FLUORESCENS

    Energy Technology Data Exchange (ETDEWEB)

    Daniel Molloy

    2003-08-04

    Under this USDOE-NETL contract, the bacterium Pseudomonas fluorescens is being developed as a biocontrol agent for zebra mussels. The specific purpose of the contract is to identify biotic and abiotic factors that affect mussel kill. Ingestion of these bacteria by zebra mussels is required to achieve kill, and tests evaluating factors that relate to mussel feeding are contained in this report. Specifically the impact of the following two factors were investigated: (1) Mussel siphoning behavior--In nature, zebra mussels typically have their two shells spread apart and their inhalant siphon tube extended from between their shells for taking food particles into their mantle cavities (Fig. 1). Our tests indicated that there is a direct correlation between mussel siphoning activity and mussel mortality achieved by a bacterial treatment. Therefore, to encourage mussel feeding on bacteria, future pipe treatments within power plants should be carried out using procedures which minimize disturbance to mussel siphoning. 2. Naturally suspended particle loads--Since bacterial cells are lethal only if ingested by mussels, waters containing very high levels of naturally suspended particles might reduce the mortality that can be achieved by a bacterial treatment. If true, this inhibition might occur as a result of particle exclusion, i.e., there could be reduced ingestion of bacterial cells since they represent a reduced percentage of all particles ingested. Our tests indicated that a range of particle concentrations that might naturally exist in a turbid river did not inhibit mussel kill by the bacterial cells, but that an artificially high load of natural particles was capable of causing a reduction in kill. To be conservative, therefore, future pipe treatments should be timed to occur when intake waters have relatively low quantities of naturally suspended particulate matter.

  18. Antifungal activity of fluconazole-loaded natural rubber latex against Candida albicans.

    Science.gov (United States)

    Yonashiro Marcelino, Mônica; Azevedo Borges, Felipe; Martins Costa, Ana Flávia; de Lacorte Singulani, Junya; Ribeiro, Nathan Vinícius; Barcelos Costa-Orlandi, Caroline; Garms, Bruna Cambraia; Soares Mendes-Giannini, Maria José; Herculano, Rondinelli Donizetti; Fusco-Almeida, Ana Marisa

    2018-03-01

    This work aimed to produce a membrane based on fluconazole-loaded natural rubber latex (NRL), and study their interaction, drug release and antifungal susceptibility against Candida albicans. Fluconazole-loaded NRL membrane was obtained by casting method. The Fourier Transform Infrared Spectroscopy showed no modifications either in NRL or fluconazole after the incorporation. Mechanical test presented low Young's modulus and high strain, indicating the membranes have sufficient elasticity for biomedical application. The bio-membrane was able to release the drug and inhibit the growth of C. albicans as demonstrated by disk diffusion and macrodilution assays. The biomembrane was able to release fluconazole and inhibit the growth of C. albicans, representing a promising biomaterial for skin application.

  19. Autonomous physics-based color learning under daylight

    Science.gov (United States)

    Berube Lauziere, Yves; Gingras, Denis J.; Ferrie, Frank P.

    1999-09-01

    An autonomous approach for learning the colors of specific objects assumed to have known body spectral reflectances is developed for daylight illumination conditions. The main issue is to be able to find these objects autonomously in a set of training images captured under a wide variety of daylight illumination conditions, and to extract their colors to determine color space regions that are representative of the objects' colors and their variations. The work begins by modeling color formation under daylight using the color formation equations and the semi-empirical model of Judd, MacAdam and Wyszecki (CIE daylight model) for representing the typical spectral distributions of daylight. This results in color space regions that serve as prior information in the initial phase of learning which consists in detecting small reliable clusters of pixels having the appropriate colors. These clusters are then expanded by a region growing technique using broader color space regions than those predicted by the model. This is to detect objects in a way that is able to account for color variations which the model cannot due to its limitations. Validation on the detected objects is performed to filter out those that are not of interest and to eliminate unreliable pixel color values extracted from the remaining ones. Detection results using the color space regions determined from color values obtained by this procedure are discussed.

  20. Spore load and immune response of honey bees naturally infected by Nosema ceranae.

    Science.gov (United States)

    Li, Wenfeng; Evans, Jay D; Li, Jianghong; Su, Songkun; Hamilton, Michele; Chen, Yanping

    2017-12-01

    Nosema ceranae causes widespread infection in adult workers of European honey bees, Apis mellifera, and has often been linked to honey bee colony losses worldwide. Previous investigations of honey bee immune response to N. ceranae infection were largely based on laboratory experiment, however, little is known about the immune response of honey bees that are naturally infected by N. ceranae. Here, we compared the infection levels of N. ceranae in three different categories of adult bees (emergent bees, nurses, and foragers) and detected the host immune response to the N. ceranae infection under natural conditions. Our studies showed that the Nosema spore load and infection prevalence varied among the different types of adult workers, and both of them increased as honey bees aged: No infection was detected in emergent bees, nurses had a medium spore load and prevalence, while foragers were with the highest Nosema infection level and prevalence. Quantification of the mRNA levels of antimicrobial peptides (abaecin, apidaecin, defensin-1, defensin-2, and hymenoptaecin) and microbial recognition proteins (PGRP-S1, PGRP-S2, PGRP-S3, PGRP-LC, GNBP1-1, and GNBP1-2) confirmed the involvement of the Toll and/or Imd immune pathways in the host response to N. ceranae infection, and revealed an activation of host immune response by N. ceranae infection under natural conditions. Additionally, the levels of immune response were positively correlated with the Nosema spore loads in the infected bees. The information gained from this study will be relevant to the predictive modeling of honey bee disease dynamics for Nosema disease prevention and management.

  1. Quantitative molecular viral loads in 7 horses with naturally occurring equine herpesvirus-1 infection.

    Science.gov (United States)

    Estell, K E; Dawson, D R; Magdesian, K G; Swain, E; Laing, S T; Siso, S; Mapes, S; Pusterla, N

    2015-11-01

    Data associating quantitative viral load with severity, clinical signs and survival in equine herpesvirus-1 myeloencephalopathy (EHM) have not been reported. To report the clinical signs, treatment, and temporal progression of viral loads in 7 horses with naturally occurring EHM and to examine the association of these factors with survival. Retrospective case series. The population included 7 horses with EHM presented to the University of California, Davis William R. Pritchard Veterinary Medical Teaching Hospital from May to September 2011. Horses were graded using a neurological grading scale. Daily quantitative PCR was performed on nasal secretions and whole blood. Treatment, survival, outcome and histopathology were reported. At presentation, one horse was neurological grade 5/5, 3 were grade 4/5 and 3 were grade 3/5. All were treated with anti-inflammatory drugs, valacyclovir and management in a sling if necessary. All were infected with equine herpesvirus-1 of DNA polymerase D752 genotype. Peak viral load in nasal secretions and blood of 5 survivors ranged from 6.9 × 10(3) to 2.81 × 10(5) (median 5.11 × 10(4) ) and from 143 to 4340 gB gene copies/million eukaryotic cells (median 3146), respectively. The 2 nonsurvivors presented with grade 3/5 neurological signs and progressed to encephalopathy. Peak viral load was higher in nonsurvivors, with levels in nasal secretions of 1.9 × 10(9) and 2.2 × 10(9) and in blood of 2.05 × 10(4) and 1.02 × 10(5) gB gene copies/million eukaryotic cells. Case fatality was 2/7. Nonsurvivors had viral loads 1000-fold higher in nasal secretions and 10-fold higher in blood than survivors. There was no relationship between severity of clinical signs at presentation and survival. Thus, encephalopathy and high viral load were negatively associated with survival in this population. Further research should be performed to determine whether high viral loads are associated with encephalopathy and poor prognosis. The Summary is

  2. A risk analysis for natural-draught cooling towers under wind load

    International Nuclear Information System (INIS)

    Niemann, H.J.

    1977-01-01

    A satisfactory safety level of natural-draught cooling towers is usually reached by assuming an extreme wind load, for which the probability of being exceeded is very low. Taking into account the dispersion of strength, the relevant extreme wind velocity for the limiting carrying capacity is calculated for a desired probability of failure. Compared with the method of partial safety coefficients, the reliability can be calculated more exactly in this way, even though the probability distribution of the extreme wind velocity must be extrapolated from limited observations. (orig.) [de

  3. Discharge Burnup Evaluation of Natural Uranium Loaded CANFLEX-43 Fuel Bundle

    International Nuclear Information System (INIS)

    Roh, Gyu Hong; Kim, Yong Hee; Kim, Won Young; Park, Joo Hwan

    2009-11-01

    Using WIMS-AECL code, which is 2-dimensional lattice core used in CANDU physics calculation, the discharge burnup of the natural uranium loaded CANFLEX-43 fuel bundle was evaluated by comparing the discharge burnup of standard 37 element fuel bundle. When the discharge burnup of the standard 37 element fuel is 7,200 MWd/MTU, that of the CANFLEX 43 fuel bundle was evaluated as 7,077 MWd/MTU, by applying the same lattice conditions for both fuel bundles

  4. Acoustic signal propagation and measurement in natural stream channels for application to surrogate bed load measurements: Halfmoon Creek, Colorado

    Science.gov (United States)

    Monitoring sediment-generated noise using submerged hydrophones is a surrogate method for measuring bed load transport in streams with the potential for improving estimates of bed load transport through widespread, inexpensive monitoring. Understanding acoustic signal propagation in natural stream e...

  5. Daylight levels during the solar eclipse of 11 August 1999

    Science.gov (United States)

    Darula, S.; Kambezidis, H. D.; Kittler, R.

    Solar eclipses are unique phenomena not only for astronomical and space observations but also for terrestrial; they create unique conditions of sunbeam blockage which cause not only the reduction of direct sunlight but also the dimming of skylight from the whole sky vault. Very favorable conditions were met during the recent August 1999 solar eclipse in Athens, Greece and Bratislava, Slovakia. General class daylight stations operate within the International Daylight Measurements Program in the two cities. One-minute data of global/diffuse illuminance and zenith luminance from those stations have been used to provide information about their levels and the daylight reduction rate during the eclipse. An approximate formula for the estimation of sunlight and skylight illuminance levels as well as zenith luminance using relative luminance sky patterns is also presented in this work. To achieve this, recently developed sky standards together with their parameterizations are utilized.

  6. Impact of three window configurations on daylight conditions

    DEFF Research Database (Denmark)

    Dubois, Marie-Claude; Sørensen, Karl Grau; Traberg-Borup, Steen

    The report describes the results of a pilot study on daylight conditions in simple rooms of residential buildings. As a tool for the analyses the Radiance Lighting Simulating System was used to simulate one room with three different window configurations, a vertical window, a dormer window......, and a roof window. The simulations were performed for overcast sky conditions and under one sunny sky, for two different times of the day. The study shows that the window configuration affects the daylight conditions (distribution and intensity) significantly. The roof window results in a higher (average......) daylight factor on a horizontal plane, i.e. more than twice as high compared with the vertical window, and more than triple as high compared with the dormer window....

  7. Cutaneous leishmaniasis responds to daylight-activated photodynamic therapy

    DEFF Research Database (Denmark)

    Enk, C D; Nasereddin, A; Alper, R

    2015-01-01

    BACKGROUND: Cutaneous leishmaniasis (CL) is endemic in Israel, with hundreds of new cases reported in recent years. Photodynamic therapy (PDT) is highly effective for treatment of CL, but requires equipment available only at specialized centres. Daylight-activated PDT (DA-PDT) abolishes the need...... application of a thick layer of 16% methyl aminolaevulinate and 30-min occlusion, the lesions were exposed to daylight for 2·5 h. Treatment sessions were repeated at weekly intervals until clinical and microbiological cure. Control lesions were either treated with cryotherapy or left untreated. RESULTS...

  8. Design and evaluation of daylighting applications of holographic glazings

    Energy Technology Data Exchange (ETDEWEB)

    Papamichael, K.; Ehrlich, C.; Ward, G.

    1996-12-01

    According to the contractual agreement, BTP would develop a computer model of the POC holographic structures and then simulate the performance of alternative designs using the RADIANCE lighting and rendering computer program [Ward 1990]. The RADIANCE model would then be used to evaluate the daylight performance of alternative designs of holographic glazings in a prototypical office space. The simulation process would be validated against actual photometric measurements of holographic glazing samples developed by POC. The results would be used to evaluate the potential for increased electric lighting savings through increased daylight illuminance levels at distances more than 15 ft--20 ft (4.6 m--6.1 m ) from the window wall.

  9. Daylight Influence on Colour Design : Empirical Study on Perceived Colour and Colour Experience Indoors

    OpenAIRE

    Hårleman, Maud

    2007-01-01

    It is known that one and the same interior colouring will appear different in rooms with windows facing north or facing south, but it is not known how natural daylight from these two compass points affects perceived colour and the ways in which colour is experienced. The objective is to describe the perceived colours to be expected in rooms with sunlight and diffused light, and thus develop a tool for colour design. Two empirical investigations provide the basis for six attached papers. The m...

  10. Imbalance of Nature due to Contaminant Loads in the Culiacan River Watershed, Sinaloa, México

    Science.gov (United States)

    García Páez, F.; Ley-Aispuro, E.

    2013-05-01

    The Culiacan River discharges runoff from a large agricultural watershed into the wetlands at Ensenada de Pabellones ranked as a priority marine region of Mexico due to its high biodiversity and the economic importance of its fishing resources. This research estimated potential contaminant loads for BOD5, TSS, N and P from stormwater runoff and associated land use in the watershed. Previous studies had demonstrated the imbalance of nature due to land use change causing contamination by heavy metals, pesticides, sediment, phosphorus and eutrophication (Lopez and Osuna, 2002; Green and Paez, 2004, Gonzalez et al., 2006; Osuna et al., 2007). The methodology included: Characterizing the watershed according to land use, soil, vegetation, annual runoff and population density by sub-watershed; estimating the potential contaminant load and annual average concentrations of contaminants using the PLOAD program, comparing the result with monitored contaminant concentrations; and identifying the impact of pollutant loads in the watershed and coastal ecosystems and proposing management strategies to reduce or reverse the imbalance of nature caused by contamination in the Culiacan River watershed. Calculated contaminant loads in tonne/year were 13,682.4 of BOD5; 503,621.8 of TSS; 5,975.7 of N and 1,789.1 of P. The Tamazula and Humaya rivers watersheds provide 72% of the total load of BOD5, 68.5% of TSS, 77.6% of N and 62.7% of P discharged to the wetlands. Monitored results include: 89% of temperature observations were above 21°C, which is stressful to aquatic life due to a subsequent decrease in dissolved oxygen; 100% of the observations of P exceeded the ecological criteria for water quality; 71.5% of the observations for DO from 2001 to 2011, were above the ecological criteria for protection of aquatic life and 91.5% met the criteria for use in drinking water; 100% of the observations for BOD5 values remained in the range of Excellent to Good; 22% of the observations for the

  11. Daylight savings time transitions and the incidence rate of unipolar depressive episodes

    DEFF Research Database (Denmark)

    Hansen, Bertel T; Sønderskov, Kim M; Hageman, Ida

    2017-01-01

    Background: Daylight savings time transitions affect approximately 1.6 billion people worldwide. Prior studies have documented associations between daylight savings time transitions and adverse health outcomes, but it remains unknown whether they also cause an increase in the incidence rate...... of depressive episodes. This seems likely because daylight savings time transitions affect circadian rhythms, which are implicated in the etiology of depressive disorder. Therefore, we investigated the effects of daylight savings time transitions on the incidence rate of unipolar depressive episodes. Methods...

  12. Predicting daylight illuminance on inclined surfaces using sky luminance data

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.H.W.; Lau, C.C.S.; Lam, J.C. [City University of Hong Kong, Kowloon (China). Dept. of Building and Construction

    2005-07-01

    Daylight illuminance, particularly on vertical surfaces, plays a major role in determining and evaluating the daylighting performance of a building. In many parts of the world, however, the basic daylight illuminance data for various vertical planes are not always readily available. The usual method to obtain diffuse illuminance on tilted planes would be based on inclined surface models using data from the horizontal measurements. Alternatively, the diffuse illuminance on a sloping plane can be computed by integrating the luminance distribution of the sky 'seen' by the plane. This paper presents an approach to estimate the vertical outdoor illuminance from sky luminance data and solar geometry. Sky luminance data recorded from January 1999 to December 2001 in Hong Kong and generated by two well-known sky luminance models (Kittler and Perez) were used to compute the outdoor illuminance for the four principal vertical planes (N, E, S and W). The performance of this approach was evaluated against data measured in the same period. Statistical analysis indicated that using sky luminance distributions to predict outdoor illuminance can give reasonably good agreement with measured data for all vertical surfaces. The findings provide an accurate alternative to determine the amount of daylight on vertical as well as other inclined surfaces when sky luminance data are available. (author)

  13. Daylighting System Based on Novel Design of Linear Fresnel lens

    Directory of Open Access Journals (Sweden)

    Thanh Tuan Pham

    2017-10-01

    Full Text Available In this paper, we present a design and optical simulation of a daylighting system using a novel design of linear Fresnel lens, which is constructed based on the conservation of optical path length and edge ray theorem. The linear Fresnel lens can achieve a high uniformity by using a new idea of design in which each groove of the lens distributes sunlight uniformly over the receiver so that the whole lens also uniformly distributes sunlight over the receiver. In this daylighting system, the novel design of linear Fresnel lens significantly improves the uniformity of collector and distributor. Therefore, it can help to improve the performance of the daylighting system. The structure of the linear Fresnel lenses is designed by using Matlab. Then, the structure of lenses is appreciated by ray tracing in LightToolsTM to find out the optimum lens shape. In addition, the simulation is performed by using LightToolsTM to estimate the efficiency of the daylighting system. The results show that the designed collector can achieve the efficiency of ~80% with the tolerance of ~0.60 and the concentration ratio of 340 times, while the designed distributor can reach a high uniformity of >90%.

  14. Solar Shading System Based on Daylight Directing Glass Lamellas

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Santos, Inês; Svendsen, Svend

    2008-01-01

    The overheating problems in office buildings must be solved with efficient solar shadings in order to reduce the energy demand for cooling and ventilation. At the same time the solar shading should not reduce the daylight level in the building on overcast days because it would result in a lower...

  15. Daylight Saving Time Transitions and Road Traffic Accidents

    Directory of Open Access Journals (Sweden)

    Tuuli Lahti

    2010-01-01

    Full Text Available Circadian rhythm disruptions may have harmful impacts on health. Circadian rhythm disruptions caused by jet lag compromise the quality and amount of sleep and may lead to a variety of symptoms such as fatigue, headache, and loss of attention and alertness. Even a minor change in time schedule may cause considerable stress for the body. Transitions into and out of daylight saving time alter the social and environmental timing twice a year. According to earlier studies, this change in time-schedule leads to sleep disruption and fragmentation of the circadian rhythm. Since sleep deprivation decreases motivation, attention, and alertness, transitions into and out of daylight saving time may increase the amount of accidents during the following days after the transition. We studied the amount of road traffic accidents one week before and one week after transitions into and out of daylight saving time during years from 1981 to 2006. Our results demonstrated that transitions into and out of daylight saving time did not increase the number of traffic road accidents.

  16. Effect of window glazing on colour quality of transmitted daylight

    NARCIS (Netherlands)

    Dangol, R.; Kruisselbrink, T.W.; Rosemann, A.L.P.

    2017-01-01

    In this study, the colour quality of the daylight transmitted through different window glazing types is evaluated. The analysis considered four different types of window glazing: laminated, monolithic, coated and applied film glazing ranging in luminous transmittance from around 0.97 to <0.1. The

  17. The effect of different weather data sets and their resolution on climate-based daylight modelling

    DEFF Research Database (Denmark)

    Iversen, A; Svendsen, Svend; Nielsen, Toke Rammer

    2013-01-01

    Climate-based daylight modelling is based on the available weather data, which means that the weather data used as input to the daylight simulations are of great importance. In this paper, the effect on the outcome of the daylight simulations of using one weather data file rather than another...

  18. Use of 198 Au, with surface labelling, in the study of solid transport by bed load in large natural channels

    International Nuclear Information System (INIS)

    Nakahira, S.

    1987-01-01

    The present study aims to present a method of measuring the bed load transport using a radioisotope technique in large natural channels. This study describes the basic principles of radioisotope application in this field, emphasizing the use of 198 Au for surface labelling of a natural sediment. Moreover, it presents the theoretical aspects, critical analysis, recommendations and comments on the methodology proposed. (author)

  19. Properties of natural rubber/attapulgite composites prepared by latex compounding method: Effect of filler loading

    International Nuclear Information System (INIS)

    Muttalib, Siti Nadzirah Abdul; Othman, Nadras; Ismail, Hanafi

    2015-01-01

    This paper reports on the effect of filler loading on properties of natural rubber (NR)/attapulgite (ATP) composites. The NR/ATP composites were prepared by latex compounding method. It is called as masterbatch. The masterbatch was subsequently added to the NR through melt mixing process. The vulcanized NR/ATP composites were subjected to mechanical, swelling and morphological tests. All the results were compared with NR/ATP composites prepared by conventional system. The composites from masterbatch method showed better results compared to composites prepared by conventional method. They have higher tensile properties, elongation at break and tear strength. The images captured through scanning electron microscopy test revealed the improvement of tensile strength in masterbatch NR/ATP composites. It can be seen clearly that masterbatch NR/ATP have better filler dispersion compared to conventional method NR/ATP composites

  20. Properties of natural rubber/attapulgite composites prepared by latex compounding method: Effect of filler loading

    Energy Technology Data Exchange (ETDEWEB)

    Muttalib, Siti Nadzirah Abdul, E-mail: sitinadzirah.amn@gmail.com; Othman, Nadras, E-mail: srnadras@usm.my; Ismail, Hanafi, E-mail: ihanafi@usm.my [School of Materials and Mineral Resources Engineering, Engineering Campus, Universiti Sains Malaysia, Seri Ampangan, 14300 Nibong Tebal, Pulau Pinang (Malaysia)

    2015-07-22

    This paper reports on the effect of filler loading on properties of natural rubber (NR)/attapulgite (ATP) composites. The NR/ATP composites were prepared by latex compounding method. It is called as masterbatch. The masterbatch was subsequently added to the NR through melt mixing process. The vulcanized NR/ATP composites were subjected to mechanical, swelling and morphological tests. All the results were compared with NR/ATP composites prepared by conventional system. The composites from masterbatch method showed better results compared to composites prepared by conventional method. They have higher tensile properties, elongation at break and tear strength. The images captured through scanning electron microscopy test revealed the improvement of tensile strength in masterbatch NR/ATP composites. It can be seen clearly that masterbatch NR/ATP have better filler dispersion compared to conventional method NR/ATP composites.

  1. Tensile behaviour of natural fibres. Effect of loading rate, temperature and humidity on the “accommodation” phenomena

    Directory of Open Access Journals (Sweden)

    Placet V.

    2010-06-01

    Full Text Available The use of natural fibres in high performance composite requires an accurate understanding of the mechanical behaviour of the fibres themselves. As for all biobased materials, the mechanical properties of natural fibres depend generally on the testing rate and on the environmental conditions. In addition, natural fibres as hemp for example exhibit a particular mechanism of stiffness increase and accommodation phenomena under cyclic loading. Loading rate, temperature and humidity effects on the viscoelastic properties of hemp fibres were investigated in this work. The collected results clearly emphasis the involvement of time-dependant and mechano-sorptive mechanisms.

  2. NOUR. Daylighting and thermal effects of windows in desert houses

    Energy Technology Data Exchange (ETDEWEB)

    Ouahrani, Djamel

    1999-07-01

    This study is on a combined effect of window, the daylighting and the thermal effects, in desert houses. It is comprised of two complementary studies. In the introduction a historical review on the development of using daylight has been carried out in order to place the case study in a historical perspective. The first study is comprehensive and contains two main parts. In the first part a study was carried out on the people and history of the town of Ghardaia in Southern Algeria. This was done in order to understand the architectural form of that region. The second part is experimental and consists of two field studies carried out in Ghardaia. Their aim was to investigate the influence of daylight and temperature on the use of residential houses. This investigation included both traditional and 'modern' houses, the modern having relatively large windows similar to those of the northern part of Algeria, the traditional ones having small or no windows. The second study is also experimental consisting of computer parametric studies on window design from two standpoints, namely daylighting level and thermal effects of windows in desert houses. A typical traditional house is described as it was observed. Then the recorded light values are presented and commented upon. In the second part, three types of modern houses observed in the field studies are presented and compared to the traditional archetype. The comparison especially dwells on the relative effectiveness of the two systems of daylighting. In the third part, focusing on various issues of lighting, the results of interviews with the inhabitants are presented. The historical studies indicate that the process of housing development, in several respects, has reached a certain quality (social, technology, and adaptation to climate) appropriate to the local original context, but that development has slowed down. The results of the lighting study indicate that the use of more windows in modern houses

  3. NOUR. Daylighting and thermal effects of windows in desert houses

    Energy Technology Data Exchange (ETDEWEB)

    Ouahrani, Djamel

    1999-07-01

    This study is on a combined effect of window, the daylighting and the thermal effects, in desert houses. It is comprised of two complementary studies. In the introduction a historical review on the development of using daylight has been carried out in order to place the case study in a historical perspective. The first study is comprehensive and contains two main parts. In the first part a study was carried out on the people and history of the town of Ghardaia in Southern Algeria. This was done in order to understand the architectural form of that region. The second part is experimental and consists of two field studies carried out in Ghardaia. Their aim was to investigate the influence of daylight and temperature on the use of residential houses. This investigation included both traditional and 'modern' houses, the modern having relatively large windows similar to those of the northern part of Algeria, the traditional ones having small or no windows. The second study is also experimental consisting of computer parametric studies on window design from two standpoints, namely daylighting level and thermal effects of windows in desert houses. A typical traditional house is described as it was observed. Then the recorded light values are presented and commented upon. In the second part, three types of modern houses observed in the field studies are presented and compared to the traditional archetype. The comparison especially dwells on the relative effectiveness of the two systems of daylighting. In the third part, focusing on various issues of lighting, the results of interviews with the inhabitants are presented. The historical studies indicate that the process of housing development, in several respects, has reached a certain quality (social, technology, and adaptation to climate) appropriate to the local original context, but that development has slowed down. The results of the lighting study indicate that the use of more windows in modern houses constitutes a

  4. The nature of operating flight loads and their effect on propulsion system structures

    Science.gov (United States)

    Dickenson, K. H.; Martin, R. L.

    1981-01-01

    Past diagnostics studies revealed the primary causes of performance deterioration of high by-pass turbofan engines to be flight loads, erosion, and thermal distortion. The various types of airplane loads that are imposed on the engine throughout the lifetime of an airplane are examined. These include flight loads from gusts and maneuvers and ground loads from takeoff, landing, and taxi conditions. Clarification is made in definitions of the airframer's limit and ultimate design loads and the engine manufacturer's operating design loads. Finally, the influence of these loads on the propulsion system structures is discussed.

  5. The costs and benefits of using daylight guidance to light office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mayhoub, M.S.; Carter, D.J. [School of Architecture, University of Liverpool (United Kingdom)

    2011-03-15

    Daylight guidance systems are linear devices that channel daylight into the core of a building. This paper analyses costs and benefits of using the two main classes of daylight guidance to light offices as an alternative to conventional electric lighting. The work demonstrates that daylight guidance is generally not economical using conventionally accepted measures of both cost and benefit. It is shown that if intangible benefits associated with the delivery of daylight to offices are included in an analysis, a more favourable balance of cost and benefit is obtained. The implications of this for practical use of the systems are discussed. (author)

  6. DAYLIGHTING PERFORMANCE OF HORIZONTAL LIGHT PIPE BRANCHING ON OPEN PLAN OFFICE SPACE

    Directory of Open Access Journals (Sweden)

    Feny ELSIANA

    2015-12-01

    Full Text Available For daylighting purpose, office buildings should have a shallow plan and increase the ratio of surface to building’s volume. However, intensive use of air-conditioning drives office building’s plan to be deep with a minimum surface to volume ratio. This leads to the presence of areas that have insufficient daylight level at the work plane. Considering limitations of some daylighting methods in distributing daylight to these areas, Horizontal Light Pipe (HLP was selected. The aim of this research was to evaluate and explain the effect of HLP branching on daylight quantity and distribution inside open plan office space. Experimental with simulation as a tool was used as the research method. HLP branching’s uniformity ratio, illuminance and Daylight Factor were compared with unbranching HLP, simultaneously with daylighting standards. Results showed that office space with HLP-L branching had higher daylight level than HLP-T branching, 296 lux and 295 lux, HLP-L and HLP-T, respectively. However, HLP-T branching distributed daylight more evenly than HLP-L branching, with uniformity ratio as 1.49:1 and 1.50:1, HLP-T and HLP-L, respectively. Both of them met the illuminance target value and uniformity at work plane. Light’s deflection and improvement amount of opening distribution decreased average illuminance and Daylight Factor up to 3.59%. Those also decreased uniformity of daylight inside the space.

  7. Phases of daylight and the stability of color perception in the near peripheral human retina.

    Science.gov (United States)

    Panorgias, Athanasios; Kulikowski, Janus J; Parry, Neil R A; McKeefry, Declan J; Murray, Ian J

    2012-03-01

    Typical daylight extends from blue (morning sky) to orangey red (evening sky) and is represented mathematically as the Daylight Locus in color space. In this study, we investigate the impact of this daylight variation on human color vision. Thirty-eight color normal human observers performed an asymmetric color match in the near peripheral visual field. Unique hues were identified using a naming paradigm. The observers' performance for matching was almost perfectly coincident with the Daylight Locus but declined markedly in other regions. Interobserver variability reached a conspicuous minimum adjacent to the Daylight Locus and was maximal in the red and yellowish-green regions. In the naming task, unique blue and yellow were virtually coincident with the Daylight Locus. The results suggest that the mechanisms of color perception mediated by the phylogenetically older (blue-yellow) color pathway have been strongly influenced by the different phases of daylight.

  8. Investigation of Architectural Strategies in Relation to Daylight and Integrated Design

    DEFF Research Database (Denmark)

    Jørgensen, Michael; Iversen, Anne; Bjerregaard Jensen, Lotte

    2012-01-01

    his paper investigates the use of daylight in three architecturally successful buildings. The aim is to discuss the challenges and opportunities of architectural daylight strategies in relation to integrated design. All these buildings were designed with the focus on a strategy of using daylight...... to create well-lit, exciting spaces and spatial sequences. The original ideas, thoughts, and decisions behind the designs and daylight strategy are compared with answers in questionnaires from test subjects who have experienced the space and lighting conditions created. The results indicate...... that the architectural daylight strategies formulated by the architects and engineers at the beginning of the design process are actually experienced by the “users” in the existing buildings. The architectural daylight strategy was different in each of the three libraries, and analysis of the results shows that daylight...

  9. Loads Bias Genetic and Signaling Switches in Synthetic and Natural Systems

    Science.gov (United States)

    Medford, June; Prasad, Ashok

    2014-01-01

    Biological protein interactions networks such as signal transduction or gene transcription networks are often treated as modular, allowing motifs to be analyzed in isolation from the rest of the network. Modularity is also a key assumption in synthetic biology, where it is similarly expected that when network motifs are combined together, they do not lose their essential characteristics. However, the interactions that a network module has with downstream elements change the dynamical equations describing the upstream module and thus may change the dynamic and static properties of the upstream circuit even without explicit feedback. In this work we analyze the behavior of a ubiquitous motif in gene transcription and signal transduction circuits: the switch. We show that adding an additional downstream component to the simple genetic toggle switch changes its dynamical properties by changing the underlying potential energy landscape, and skewing it in favor of the unloaded side, and in some situations adding loads to the genetic switch can also abrogate bistable behavior. We find that an additional positive feedback motif found in naturally occurring toggle switches could tune the potential energy landscape in a desirable manner. We also analyze autocatalytic signal transduction switches and show that a ubiquitous positive feedback switch can lose its switch-like properties when connected to a downstream load. Our analysis underscores the necessity of incorporating the effects of downstream components when understanding the physics of biochemical network motifs, and raises the question as to how these effects are managed in real biological systems. This analysis is particularly important when scaling synthetic networks to more complex organisms. PMID:24676102

  10. Does Daylight Saving Save Energy? A Meta-Analysis

    OpenAIRE

    Havránek, Tomáš; Herman, Dominik; Irsova, Zuzana

    2016-01-01

    The original rationale for adopting daylight saving time (DST) was energy savings. Modern research studies, however, question the magnitude and even direction of the effect of DST on energy consumption. Representing the first meta-analysis in this literature, we collect 162 estimates from 44 studies and find that the mean reported estimate indicates modest energy savings: 0.34% during the days when DST applies. The literature is not affected by publication bias, but the results vary systemati...

  11. Byron G. Rogers Federal Building Harvests Daylight and Super Savings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-01-01

    Case study describes how the Byron G. Rogers Federal Building replaced existing T12 and T8 luminaires with LED dedicated troffers with advanced controls. Together these measures cut lighting energy use by nearly 60% in the 18-story, 791,000-square-foot facility. The new lighting control system provides automated dimming of lights down to 0% output when daylight provides adequate light levels. The project earned GSA an award for exemplary performance from the Interior Lighting Campaign in 2016.

  12. Daylighting in linear atrium buildings at high latitudes

    Energy Technology Data Exchange (ETDEWEB)

    Matusiak, Barbara

    1998-12-31

    This thesis proposes new criteria for visual comfort based on knowledge of visual perception and a method for estimating the modelling ability of light by using inter-reflection calculations. Simplified calculations are presented for the daylight factor in linear building structures, using the projected solid angle principle, for uniform sky and for CIE overcast sky conditions. The calculations are compared with experimental results. Simple diagrams are created based on calculations of the mean daylight factor in rooms adjacent to a narrow street. These diagrams and presented formulas and tables can be used as a simple design tool. Daylighting strategies for linear atrium buildings at high latitudes are developed and examined. These strategies are divided into three groups: (1) the atrium space and facades as light conductor/reflector, (2) the glass roof as a light conductor, and (3) light reflectors on the neighbouring roof. The atrium space and facade strategies are subdivided into passive and active. The strategies connected to the glazed roof includes different configurations of glazing: horizontal, single pitched, double pitched, and the use of laser cut panels and prismatic panels in the glazed roof. The shapes of reflectors on the neighbouring roof are a flat reflector, a parabolic reflector and a parabolic concentrator. Strategies from all three groups are examined on a physical model of scale 1:20 in the artificial sky of mirror box type. Simulations with artificial sun have also been done. The results from model studies are compared with computer simulations. All the active daylighting systems designed for use in the atrium space or on the atrium facades have a huge potential for use in atrium buildings. From the strategies connected with the glazed roof the negatively sloped glass is found to be the best alternative for glazed roofs at high latitudes. Among the roof reflectors, the flat one performs best. 82 refs., 122 figs., 27 tabs.

  13. Optimal tree design for daylighting in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hongbing, Wang [College of Landscape Architecture, Beijing Forestry University, 35, East Qinghua Rd., Beijing (China); Shanghai Botanical Garden, 1111, Longwu Rd., Shanghai (China); Jun, Qin; Yonghong, Hu [Shanghai Botanical Garden, 1111, Longwu Rd., Shanghai (China); Li, Dong [College of Landscape Architecture, Beijing Forestry University, 35, East Qinghua Rd., Beijing (China)

    2010-12-15

    Urban reforestation is advocated as an efficient countermeasure to the intensification of urban heat islands. The greening and beautification of residential quarters is one of the main concerns of residents, while lighting and ventilation are two main energy-consuming building services. Hence, the tree layout in green space between buildings is important, and it is necessary to determine the relationships between trees and buildings. This study takes Shanghai as a case study to optimize tree design between residential buildings and meet good daylighting requirements. Models were made using software such as AutoCAD and SketchUp. The relationships between maximum tree height and building separation were determined. For the same building layout, there were different tree height limits according to crown shape; the order of decreasing height limits was cylindrical, conical, spherical, and inverted conical crowns. Three cases having different green space between building layouts were studied. Their maximum tree heights differed. Overall, our model helps us realize good daylighting of a building environment. The formula allows us to determine which trees to plant between buildings in that we can predict the effects of future tree growth on building daylighting. (author)

  14. Impact of shading on daylight quality. Simulations with radiance

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.C.

    2001-07-01

    The impact of six exterior shading devices on daylight quality and on the potential for daylight utilisation in a standard, south-oriented office room was investigated through computer simulations with Radiance. The daylight quality was evaluated by considering four performance indicators: the absolute work plane illuminance, the illuminance uniformity on the work plane, the absolute luminance in the visual field and the luminance ratios between the work plane, VDT screen and surrounding surfaces. The results indicate that the overhang, white awning and horizontal venetian blind generated work plane illuminance levels that are more suitable for offices where traditional tasks are carried out. However, these devices did not prevent high luminance values at the window. On the other hand, the grey specular screen produced unacceptably low work plane illuminance, poor illuminance uniformity and unacceptably low luminance levels which resulted in unsuitable luminance ratios between the VDT screen, work plane and surroundings. The 45 deg venetian blind, white screen and blue awning provided work plane illuminance levels suitable for offices where a combination of paper and computer work is carried out. They also provided acceptable illuminance uniformity on the work plane, suitable luminance ratios between the work plane, VDT screen and surroundings and they significantly reduced the luminance of the window. However, the blue awning had a poorer performance in December than in June and the white screen resulted in high luminance values at the window, which indicates that the best device among the ones studied was the 45 deg venetian blind.

  15. Leaching and antimicrobial properties of silver nanoparticles loaded onto natural zeolite clinoptilolite by ion exchange and wet impregnation

    CSIR Research Space (South Africa)

    Missengue, RNM

    2015-11-01

    Full Text Available This study aimed to compare the leaching and antimicrobial properties of silver that was loaded onto the natural zeolite clinoptilolite by ion exchange and wet impregnation. Silver ions were reduced using sodium borohydride (NaBH(sub4...

  16. Human genetic studies in areas of high natural radiation VI. Genetical load and ethnic group

    Energy Technology Data Exchange (ETDEWEB)

    Freire-Maia, A [Faculdade de Ciencias Medicas e Biologicas de Botucatu (Brazil). Departamento de Genetica

    1974-01-01

    The load of mutations disclosed by inbreeding, according to the ethnic group of the parents, has been analyzed in our data. Besides the total of the population, a sample with no alien ancestrals has also been analyzed. Genetic load has been studied for absortions, still births, pos-natal mortality, total mortality, anomalies, total mortality + anomalies, and abnormalities in general.

  17. Human genetic studies in areas of high natural radiation VI. Genetical load and ethnic group

    International Nuclear Information System (INIS)

    Freire-Maia, A.

    1974-01-01

    The load of mutations disclosed by inbreeding, according to the ethnic group of the parents, has been analyzed in our data. Besides the total of the population, a sample with no alien ancestrals has also been analyzed. Genetic load has been studied for absortions, still births, pos-natal mortality, total mortality, anomalies, total mortality + anomalies, and abnormalities in general [pt

  18. Method for including detailed evaluation of daylight levels in Be06

    DEFF Research Database (Denmark)

    Petersen, Steffen

    2008-01-01

    Good daylight conditions in office buildings have become an important issue due to new European regulatory demands which include energy consumption for electrical lighting in the building energy frame. Good daylight conditions in offices are thus in increased focus as an energy conserving measure....... In order to evaluate whether a certain design is good daylight design or not building designers must perform detailed evaluation of daylight levels, including the daylight performance of dynamic solar shadings, and include these in the energy performance evaluation. However, the mandatory national...... calculation tool in Denmark (Be06) for evaluating the energy performance of buildings is currently using a simple representation of available daylight in a room and simple assumptions regarding the control of shading devices. In a case example, this is leading to an overestimation of the energy consumption...

  19. Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan

    Science.gov (United States)

    Nazzal, Ali; Oki, Masato

    Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.

  20. Hybrid daylight/light-emitting diode illumination system for indoor lighting.

    Science.gov (United States)

    Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei

    2014-03-20

    A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.

  1. Using the whole-building design approach to incorporate daylighting into a retail space: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hayter, S.; Torcellini, P.; Eastment, M.; Judkoff, R.

    2000-06-21

    This paper focuses on implementation of daylighting into the Bighorn Center, a collection of home improvement retail spaces in Silverthorne, Colorado, which were constructed in three phases. Daylighting was an integral part of the design of the Phase 3 building. Energy consultants optimized the daylighting design through detailed modeling using an hourly building energy simulation tool. Energy consultants also used this tool to address the building owner's concerns related to customer comfort and increased product sales.

  2. The impact of the daylight saving time on electricity consumption-A case study from Jordan

    International Nuclear Information System (INIS)

    Awad Momani, Mohammad; Yatim, Baharudin; Ali, Mohd Alauddin Mohd

    2009-01-01

    The paper examines the impact of daylight saving time (DST) on electricity consumption in Jordan. Two types of analysis were done: the first analysis examines the impact of DST on the lighting loads based on a survey study made for residential and commercial sectors. The second examines the impact of DST on the over all electricity generation through analyzing the daily load curves (DLCs) before and after the DST onset and removal in 2000 and 2007. The results show that the application of DST during the year 2000 saves the electricity used for illumination by -0.73% but it increases the overall generation at the onset and removal of DST by 0.5% and 1.4% due to increase in the heating and cooling loads. The analysis of DLCs during the year 2007 shows similar effects as in the year 2000 except during the early morning period at the DST onset where DST decreases the demand during this time. The analysis shows that DST decreases the electricity demand at DST onset by 0.2% and increases it at DST removal by 0.3%. A possible decrease in the electricity consumption may take place if the DST is implemented from April to end of August.

  3. Essence of Daylight in the Cistercian Monastic Church of S. Bento de Cástris, Évora, Portugal

    Science.gov (United States)

    Martins, Ana M. T.; Carlos, Jorge S.

    2017-10-01

    Natural light in the Cistercian churches is closely linked not only with the liturgical requirements at the “officium” but also with the canonical hours based on the "ora et labora" dictated by the Rule of St. Benedict. The Cistercian architecture, in its beginnings (12th century forward) is characterized by austerity, simplicity and the play of light and shadow that gives value to the monastic architectural space itself, making it perfect for a contemplative experience. In the Cistercian Monastery the church is the central piece of the monastic building. Nave, transept and apse are the main architectural components to which is added the choir. This paper contextualizes the importance and close connections of natural light, within the Cistercian Monasteries architecture. Thus the essence of daylight is analysed within the Church of the Monastery of S. Bento de Cástris, in Évora, Portugal. This former Monastery (13th - 19th centuries) includes the church, at the south-eastern corner which has not only a high choir, but also a low lateral choir (within the presbytery). Its unchanged exterior walls are made of solid masonry. Although the function of the walls is primarily structural, the windows allow the daylight to penetrate the space of the church. The church has two external façades facing northeast and southeast. The combined orientation effect of the church’s main axis and the sun trajectory determines how the sunlight reaches the interior of this architectural structure. This study presents the qualitative and quantitative analysis of the luminous environment in the church of S. Bento de Cástris, being the first based on the authors’ perception of the effect of the daylight within the different areas of the enclosed space. The appreciation of the spatial experiences was supported by quantitative daylight simulations that were conducted in selected areas within the space. With this paper is intended to contribute to the debate about the specificity

  4. Daylighting as the Driving Force of the Design Process: from the Results of a Survey to the Implementation into an Advanced Daylighting Project

    Directory of Open Access Journals (Sweden)

    Valerio R.M. Lo Verso

    2014-12-01

    Full Text Available This paper presents a study for the transformation of an industrial area in Turin, Italy. The area hosts two buildings (one of which appointed as listed to be transformed into dwellings. A synergic approach was adopted which combined expertise from architecture, social-economics, psychology and building physics sciences. Building physics sciences lead the research team. A user-centered design was pursued, using a bottom-up approach. A specifically developed questionnaire was submitted on-line to potential users. The survey showed that ‘amount of daylight’, ‘size of rooms’, ‘tranquility of the area’ and ‘presence of a private garden’ were perceived by users to be the most positive aspects of both their present and future, ideal home. These results were then implemented into the project. The exploitation of daylight became the driving force of the transformation project. Especially for the listed building, skylights and light wells were designed to bring daylight into the cores of the buildings, which host common spaces such as libraries or study rooms. The amount of daylight was assessed through the legislative index of the average daylight factor and through a climate-based modeling approach, calculating dynamic metrics such as the spatial daylight autonomy and the Useful Daylight Illuminance. The paper critically compares and discusses these two approaches. Finally, the energy demand for lighting was also calculated to analyze how the increased exploitation of daylight may imply a reduced need for electricity for lighting.

  5. Impact of Furniture Layout on Indoor Daylighting Performance in Existing Residential Buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Mousavi

    2018-06-01

    Full Text Available Currently, home-based computing workspaces have developed substantially all over the world, especially in Malaysia. This growing trend attracts computer workers to run a business from their residential units. Hence, visual comfort needs to be considered in addition to thermal comfort for home workers in their residential working rooms. While such rooms are always occupied with furniture, the layout of the furniture may influence the indoor daylighting distribution. Several various furniture layouts can be arranged in a residential working room. However, to have better generalisation, this study focused on the impacts of mostly-used-furniture-layouts (MUFLs on indoor daylighting performance in residential working rooms. The field measurement was conducted in a typically furnished room under a tropical sky to validate the results of the simulation software under different sky conditions. Then, daylight ratio (DR, as a quantitative daylighting variable, and the illuminance uniformity ratio (IUR, CIE glare index (CGI, and Guth visual comfort probability (GVCP, as qualitative daylighting variables, were analysed through simulation experiments. In conclusion, by changing the furniture layout, daylight uniformity recorded the highest fluctuations in the case room among all variables. While various furniture layouts, in a residential working room in the tropics, may even slightly reduce the extreme indoor daylight quantity, they can worsen the indoor daylight quality compared to an unfurnished space. The paper shows that furniture as an interior design parameter cannot help to improve tropical daylighting performance in a building.

  6. Practicality and Performance of Daylight Trough in The Tropics: A Case Study

    Directory of Open Access Journals (Sweden)

    Gene-Harn Lim

    2016-01-01

    Full Text Available The field of office daylighting is vital for both energy efficiency practice and occupants’ visual comfort. With the emergence of green building in Malaysia, building designers are exploring avenues for energy efficiency design; one common strategy is daylighting. The majority literature reviews on daylighting are skewed towards temperate or developed countries, where sky luminous condition is different from that of the Tropics. Conventional daylighting system designs redirect daylight from the envelope or atrium openings, such as light shelves. Presumed to be the pioneer daylight trough in the Tropics, this paper presents the simulated and in-situ lighting level measurements prior to occupancy. This case study presents an as-built daylight trough design which is able to daylight the office space as deep as 6 meters sufficiently. It achieves a lighting power density 1.90W/m2 and saves 39.2% of lighting energy over conventional office lighting energy. Discussed further is the practicality of working with such a system, including cost implication, return on investment and contractual challenges in reaching a consensus on the design. The results reinforce that the effectiveness of daylighting design is very dependable on the sun path and obstacles surrounding the office tower. The RADIANCE simulation correlates well to field measurement results. Further investigation into the light trough, its lighting energy savings, users’ interaction, visual comfort, and glare is still ongoing.

  7. Analysis of impact of daylight time savings on energy use of buildings in Kuwait

    Energy Technology Data Exchange (ETDEWEB)

    Krarti, Moncef, E-mail: moncef.krarti@colorado.ed [CEAE Department, CB 428, University of Colorado, Boulder, CO 80309 (United States); Hajiah, Ali [Kuwait Institute for Scientific Research, Safat (Kuwait)

    2011-05-15

    In this paper, a detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. The simulation results indicate that the adoption of DST has mixed impacts for Kuwait. While the commercial and the governmental sectors may benefit from the DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. The overall impact of the DST implementation is rather minimal with a slight increase energy use of about 0.07% and a slight reduction in peak demand of 0.14% or about 12 MW based on 2005 electrical peak demand for Kuwait. - Research highlights: {yields} A detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. {yields} The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. {yields} It is found that while the commercial and the governmental building sectors may benefit from DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. {yields} Since the residential sector represents the majority of the electrical load in Kuwait, DST adoption was found to cause slight increase in annual electrical energy use by about 0.07% and a slight reduction in electrical peak electrical demand by about 0.14%.

  8. Analysis of impact of daylight time savings on energy use of buildings in Kuwait

    International Nuclear Information System (INIS)

    Krarti, Moncef; Hajiah, Ali

    2011-01-01

    In this paper, a detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. The simulation results indicate that the adoption of DST has mixed impacts for Kuwait. While the commercial and the governmental sectors may benefit from the DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. The overall impact of the DST implementation is rather minimal with a slight increase energy use of about 0.07% and a slight reduction in peak demand of 0.14% or about 12 MW based on 2005 electrical peak demand for Kuwait. - Research highlights: → A detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. → The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. → It is found that while the commercial and the governmental building sectors may benefit from DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. → Since the residential sector represents the majority of the electrical load in Kuwait, DST adoption was found to cause slight increase in annual electrical energy use by about 0.07% and a slight reduction in electrical peak electrical demand by about 0.14%.

  9. Effect of daylight and gamma-radiation on the colour of fabricated textile polymers

    International Nuclear Information System (INIS)

    Wahab, L.A.; Saad, M.M.; Talaat, M.H.

    2003-01-01

    The effects of gamma-irradiation (0-60 mrad) and natural daylight (0-6 months) on the color and other properties of undyed textile polymers (cotton, nylon-6, polyester/cotton blend and wool/polyester blend) were investigated using optical spectroscopy. The change in color was estimated by yellowness index (Y1) and color difference (Delta E) between the irradiated and unirradiated samples. The analysis used for dosimeter is mainly spectrophotometer in the UV and visible spectrum. Systems having a reproducible response are selected. In the case of cotton fabric the change in color and reflection are showing a promise for dosimeter of gamma-radiation. It was concluded that the whiteness (W) of synthetic and blend fabrics decreased much more than that of cotton fabrics

  10. Critical loads of nitrogen deposition and critical levels of atmospheric ammonia for semi-natural Mediterranean evergreen woodlands

    Directory of Open Access Journals (Sweden)

    P. Pinho

    2012-03-01

    Full Text Available Nitrogen (N has emerged in recent years as a key factor associated with global changes, with impacts on biodiversity, ecosystems functioning and human health. In order to ameliorate the effects of excessive N, safety thresholds such as critical loads (deposition fluxes and levels (concentrations can be established. Few studies have assessed these thresholds for semi-natural Mediterranean ecosystems. Our objective was therefore to determine the critical loads of N deposition and long-term critical levels of atmospheric ammonia for semi-natural Mediterranean evergreen woodlands. We have considered changes in epiphytic lichen communities, one of the most sensitive comunity indicators of excessive N in the atmosphere. Based on a classification of lichen species according to their tolerance to N we grouped species into response functional groups, which we used as a tool to determine the critical loads and levels. This was done for a Mediterranean climate in evergreen cork-oak woodlands, based on the relation between lichen functional diversity and modelled N deposition for critical loads and measured annual atmospheric ammonia concentrations for critical levels, evaluated downwind from a reduced N source (a cattle barn. Modelling the highly significant relationship between lichen functional groups and annual atmospheric ammonia concentration showed the critical level to be below 1.9 μg m−3, in agreement with recent studies for other ecosystems. Modelling the highly significant relationship between lichen functional groups and N deposition showed that the critical load was lower than 26 kg (N ha−1 yr−1, which is within the upper range established for other semi-natural ecosystems. Taking into account the high sensitivity of lichen communities to excessive N, these values should aid development of policies to protect Mediterranean woodlands from the initial effects of excessive N.

  11. Assessing natural and anthropogenic influences on water discharge and sediment load in the Yangtze River, China.

    Science.gov (United States)

    Zhao, Yifei; Zou, Xinqing; Liu, Qing; Yao, Yulong; Li, Yali; Wu, Xiaowei; Wang, Chenglong; Yu, Wenwen; Wang, Teng

    2017-12-31

    The water discharge and sediment load of rivers are changing substantially under the impacts of climate change and human activities, becoming a hot issue in hydro-environmental research. In this study, the water discharge and sediment load in the mainstream and seven tributaries of the Yangtze River were investigated by using long-term hydro-meteorological data from 1953 to 2013. The non-parametric Mann-Kendall test and double mass curve (DMC) were used to detect trends and abrupt change-points in water discharge and sediment load and to quantify the effects of climate change and human activities on water discharge and sediment load. The results are as follows: (1) the water discharge showed a non-significant decreasing trend at most stations except Hukou station. Among these, water discharge at Dongting Lake and the Min River basin shows a significant decreasing trend with average rates of -13.93×10 8 m 3 /year and -1.8×10 8 m 3 /year (PYangtze River. (2) No significant abrupt change-points were detected in the time series of water discharge for all hydrological stations. In contrast, significant abrupt change-points were detected in sediment load, most of these changes appeared in the late 1980s. (3) The water discharge was mainly influenced by precipitation in the Yangtze River basin, whereas sediment load was mainly affected by climate change and human activities; the relative contribution ratios of human activities were above 70% for the Yangtze River. (4) The decrease of sediment load has directly impacted the lower Yangtze River and the delta region. These results will provide a reference for better resource management in the Yangtze River Basin. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Application of automated blind for daylighting in tropical region

    International Nuclear Information System (INIS)

    Chaiwiwatworakul, Pipat; Chirarattananon, Surapong; Rakkwamsuk, Pattana

    2009-01-01

    This paper reports an experimental and simulation study on application of automated Venetian blind for daylighting in tropical climate. A horizontal blind system operating automatically under programmed control was constructed and integrated onto the glazed windows to form a window system with an automated blind in a room of a laboratory building. A dimming controller was also integrated to the lighting system of the room. Different operation schemes of the window system were devised and tested in the attempt to maximize energy savings while maintaining the quality of the visual environment in the room. Intensive measurement of illuminance of the interior space was undertaken during the experiments. A methodology for calculation of interior daylight illuminance and associated glare corresponding to the configurations of the experiments was adopted. The method was coded into a computer program. Results of calculation from the program agree well with those from experiments for all the schemes of operation conducted. The program was used to simulate the situation when each scheme of operation was implemented for a whole year. It was found that such window system with automated blind enabled energy savings of 80%, but a more sophisticated scheme also helped maintain the interior visual quality at high level.

  13. Effect of Window Glazing on Colour Quality of Transmitted Daylight

    Directory of Open Access Journals (Sweden)

    Rajendra Dangol

    2017-12-01

    Full Text Available In this study, the colour quality of the daylight transmitted through different window glazing types is evaluated. The analysis considered four different types of window glazing: laminated, monolithic, coated and applied film glazing ranging in luminous transmittance from around 0.97 to <0.1. The spectral transmittance data of different window glazing types are taken from the International Glazing Data Base (IGDB, which is maintained by Lawrence Berkeley National Laboratories (LBNL. The study showed that the CIE CRI does not always seem to be the suitable method to predict the colour quality of daylight in building for particular situations. However, in the context of this study, the prediction of colour rendering properties of window glazing by other metrics such as Colour Quality Scale (version 9, Memory CRI, Ra,D65 (adjusted CRI metric with D65 as the reference illuminant performed better. For most of the daylit situations inside the building, the chromaticity difference criterion was not met. Judging the colour quality of such situations requires different method.

  14. Proposal of the Tubular Daylight System Using Acrylonitrile Butadiene Styrene (ABS Metalized with Aluminum for Reflective Tube Structure

    Directory of Open Access Journals (Sweden)

    Anderson Diogo Spacek

    2018-01-01

    Full Text Available In the search for alternatives to reduce the consumption of electric energy, the possibility of using natural light for lighting through TDD (tubular daylight devices or TDGS (tubular daylight guidance systems appears. These natural luminaires are used in rooms where you want to save electricity and enjoy the benefits of natural light. The present work proposes the construction of a tubular system for the conduction of natural light that replaces aluminum with silver (currently marketed by several companies by polymer metallized with aluminum, offering a low cost. The polymer acrylonitrile butadiene styrene (ABS, coated with aluminum by physical vapor deposition (ionization, was evaluated for some tests to verify characteristics of the structure and the metallized surface. After the tests, the construction of the reflective tube was performed and validated in a real scale of application. The results proved the technical viability of the proposed tube construction for the realization of direct sunlight for illumination using polymeric material. Although it has produced 35% less than the reference tube, it can be marketed at an estimated cost of 50% less.

  15. An urban observatory for quantifying phosphorus and suspended solid loads in combined natural and stormwater conveyances.

    Science.gov (United States)

    Melcher, Anthony A; Horsburgh, Jeffery S

    2017-06-01

    Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.

  16. Daylight-mediated photodynamic therapy of moderate to thick actinic keratoses of the face and scalp

    DEFF Research Database (Denmark)

    Wiegell, S.R.; Fabricius, S.; Philipsen, P.A.

    2012-01-01

    response rate and light dose in patients who received an effective light dose of > 3·5 J cm . Conclusions: Daylight-mediated PDT of moderate to thick AKs was less effective than daylight-mediated PDT of thin AKs especially in some centres. However, nearly all thicker lesions (grades II and III) were...

  17. Daylight and health: A review of the evidence and consequences for the built environment

    NARCIS (Netherlands)

    M.P.J. Aarts; Joost van Hoof; M.B.C. Aries

    2015-01-01

    Daylight has been associated with multiple health advantages. Some of these claims are associations, hypotheses or beliefs. This review presents an overview of a scientific literature search on the proven effects of daylight exposure on human health. Studies were identified with a search strategy

  18. Study of effect of daylight on Building User's Performance Based on Electroencephalograph Signal

    NARCIS (Netherlands)

    Mangkuto, R.A.; Soelami, F.X.N.; Suprijanto, S.

    2009-01-01

    The use of daylighting in building nowadays has become one alternative to save electric energy consumption, particularly during daytime. Daylight is not only useful for reducing cost from electric light sources, but also give benefits both physiologically and psychologically for building users.

  19. Daylighting Concepts for University Libraries and Their Influences on Users' Satisfaction

    Science.gov (United States)

    Kilic, Didem Kan; Hasirci, Deniz

    2011-01-01

    Daylighting, a controlled architectural tool that influences users' perception and behavior, in university libraries and their influences on users' preference and satisfaction was examined in this study. The effects of daylighting in coordination with visual comfort, on university library users were measured in relation to four environmental…

  20. Daylight-mediated photodynamic therapy of basal cell carcinomas - an explorative study

    DEFF Research Database (Denmark)

    Wiegell, S R; Skødt, V; Wulf, H C

    2014-01-01

    BACKGROUND: Studies have shown that daylight-photodynamic therapy (PDT) is an effective treatment of actinic keratoses, nearly pain free and more convenient for both the clinics and patients. Treatment of basal cell carcinomas (BCCs) is another main indication for PDT. OBJECTIVES: The aim...... of this open, uncontrolled, prospective explorative study was to evaluate the efficacy of daylight-PDT for BCCs. METHODS: Twenty-one patients with a total of 32 BCCs located in the face, scalp, chest, back and lower leg received one cycle of daylight-methyl aminolevulinate (MAL)-PDT, consisting of two...... treatments 1 week apart. After sunscreen application and lesion preparation, MAL was applied and patients exposed themselves to daylight for 2½ h. Daylight exposure was monitored with a wrist-borne dosimeter. RESULTS: At 3-month follow-up, complete response was seen in 30 lesions (94%) and in 19 patients (90...

  1. Detailed simulations of lighting conditions in office rooms lit by daylight and artificial light

    DEFF Research Database (Denmark)

    Iversen, Anne

    In this thesis the effect on the annual artificial lighting demand is investigated by employing detailed simulations of lighting conditions in office rooms lit by daylight and artificial. The simulations of the artificial lighting demand is accomplished through daylight simulations in Radiance....... The detailed simulations includes studies of the resolution of different weather data sets in climate-based daylight modeling. Furthermore, influence of the electrical lighting demand by simulating with dynamic occupancy patterns is studied. Finally the thesis explores the influence of obstructions in an urban...... canyon on the daylight availability within the buildings, and hence on the energy consumption for artificial lights. The results from the thesis demonstrates that the effect on the outcome of the daylight simulations when simulating with typical weather data files for the location of Copenhagen...

  2. STRATEGI DAYLIGHTING PADA BANGUNAN MULTI-LANTAI DI ATAS DAN DI BAWAH PERMUKAAN TANAH

    Directory of Open Access Journals (Sweden)

    Danny Santoso Mintorogo

    1999-01-01

    Full Text Available One of the common factor for Energy Saving on buildings has dealed a lot with the lightings on building, especially for multi level floors above and below grade. In order for saving energy on lightings, many daylighting strategies on multi floors building are being used and under-developed by many architects. This paper discusses the strategies of the daylighting techniques on multi floors building both above and below grade Abstract in Bahasa Indonesia : Strategi hemat energi sangat erat hubungan dengan faktor penerangan dalam bangunan, lebih-lebih pada bangunan berlantai banyak diatas atau dibawah permukaan tanah. Untuk menghemat pemakaian energi listrik dari penerangan ini, maka strategi-strategi penerangan alami "Daylighting" terus dikembangkan. Tulisan ini bertujuan memaparkan berbagai strategi daylighting pada bangunan yang berlantai banyak yang dibangun diatas maupun dibawah permukaan tanah. Kata kunci : daylighting, energi

  3. Failure analysis of natural gas buried X65 steel pipeline under deflection load using finite element method

    International Nuclear Information System (INIS)

    Liu, P.F.; Zheng, J.Y.; Zhang, B.J.; Shi, P.

    2010-01-01

    A 3D parametric finite element model of the pipeline and soil is established using finite element method to perform the failure analysis of natural gas buried X65 steel pipeline under deflection load. The pipeline is assumed to be loaded in a parabolic deflection displacement along the axial direction. Based on the true stress-strain constitutive relationship of X65 steel, the elastic-plastic finite element analysis employs the arc-length algorithm and non-linear stabilization algorithm respectively to simulate the strain softening properties of pipeline after plastic collapse. Besides, effects of the soil types and model sizes on the maximum deflection displacement of pipeline are investigated. The proposed finite element method serves as a base available for the safety design and evaluation as well as engineering acceptance criterion for the failure of pipeline due to deflection.

  4. Experimental and theoretical analysis of the combustion process at low loads of a diesel natural gas dual-fuel engine

    International Nuclear Information System (INIS)

    Li, Weifeng; Liu, Zhongchang; Wang, Zhongshu

    2016-01-01

    To construct an effective method to analyze the combustion process of dual fuel engines at low loads, effects of combustion boundaries on the combustion process of an electronically controlled diesel natural gas dual-fuel engine at low loads were investigated. Three typical combustion modes, including h, m and n, appeared under different combustion boundaries. In addition, the time-sequenced characteristic and the heat release rate-imbalanced characteristic were found in the dual fuel engine combustion process. To quantify these characteristics, two quantitative indicators, including the TSC (time-sequenced coefficient) and the HBC (HRR-balanced coefficient) were defined. The results show that increasing TSC and HBC can decrease HC (hydrocarbon) emissions and improve the BTE (brake thermal efficiency) significantly. The engine with the n combustion mode can obtain the highest BTE and the lowest HC emissions, followed by m, and then h. However, the combustion process of the engine will deteriorate sharply if boundary conditions are not strictly controlled in the n combustion mode. Based on the n combustion mode, advancing the start of diesel injection significantly, using large EGR (exhaust gas recirculation) rate and appropriately intake throttling can effectively reduce HC emissions and improve the BTE of dual fuel engines at low loads with relatively high natural gas PES (percentage energy substitution). - Highlights: • We reported three typical combustion modes of a dual-fuel engine at low loads. • Time-sequenced characteristic was put forward and qualified. • HRR-imbalanced characteristic was put forward and qualified. • Three combustion modes appeared as equivalence ratio/diesel injection timing varied. • The engine performance varied significantly with different combustion mode.

  5. A short-term load forecasting model of natural gas based on optimized genetic algorithm and improved BP neural network

    International Nuclear Information System (INIS)

    Yu, Feng; Xu, Xiaozhong

    2014-01-01

    Highlights: • A detailed data processing will make more accurate results prediction. • Taking a full account of more load factors to improve the prediction precision. • Improved BP network obtains higher learning convergence. • Genetic algorithm optimized by chaotic cat map enhances the global search ability. • The combined GA–BP model improved by modified additional momentum factor is superior to others. - Abstract: This paper proposes an appropriate combinational approach which is based on improved BP neural network for short-term gas load forecasting, and the network is optimized by the real-coded genetic algorithm. Firstly, several kinds of modifications are carried out on the standard neural network to accelerate the convergence speed of network, including improved additional momentum factor, improved self-adaptive learning rate and improved momentum and self-adaptive learning rate. Then, it is available to use the global search capability of optimized genetic algorithm to determine the initial weights and thresholds of BP neural network to avoid being trapped in local minima. The ability of GA is enhanced by cat chaotic mapping. In light of the characteristic of natural gas load for Shanghai, a series of data preprocessing methods are adopted and more comprehensive load factors are taken into account to improve the prediction accuracy. Such improvements facilitate forecasting efficiency and exert maximum performance of the model. As a result, the integration model improved by modified additional momentum factor gets more ideal solutions for short-term gas load forecasting, through analyses and comparisons of the above several different combinational algorithms

  6. Innovation of natural essential oil-loaded Orabase for local treatment of oral candidiasis.

    Science.gov (United States)

    Labib, Gihan S; Aldawsari, Hibah

    2015-01-01

    Oral candidiasis may be manifested in the oral cavity as either mild or severe oral fungal infection. This infection results from the overgrowth of Candida species normally existing in the oral cavity in minute amounts based on many predisposing factors. Several aspects have spurred the search for new strategies in the treatment of oral candidiasis, among which are the limited numbers of new antifungal drugs developed in recent years. Previous studies have shown that thyme and clove oils have antimycotic activities and have suggested their incorporation into pharmaceutical preparations. This study aimed to investigate the possibility of the incorporation and characterization of essential oils or their extracted active ingredients in Orabase formulations. Orabase loaded with clove oil, thyme oil, eugenol, and thymol were prepared and evaluated for their antifungal activities, pH, viscosity, erosion and water uptake characteristics, mechanical properties, in vitro release behavior, and ex vivo mucoadhesion properties. All prepared bases showed considerable antifungal activity and acceptable physical characteristics. The release pattern from loaded bases was considerably slow for all oils and active ingredients. All bases showed appreciable adhesion in the in vitro and ex vivo studies. The incorporation of essential oils in Orabase could help in future drug delivery design, with promising outcomes on patients' well-being.

  7. Seasonality in trauma admissions - Are daylight and weather variables better predictors than general cyclic effects?

    Science.gov (United States)

    Røislien, Jo; Søvik, Signe; Eken, Torsten

    2018-01-01

    Trauma is a leading global cause of death, and predicting the burden of trauma admissions is vital for good planning of trauma care. Seasonality in trauma admissions has been found in several studies. Seasonal fluctuations in daylight hours, temperature and weather affect social and cultural practices but also individual neuroendocrine rhythms that may ultimately modify behaviour and potentially predispose to trauma. The aim of the present study was to explore to what extent the observed seasonality in daily trauma admissions could be explained by changes in daylight and weather variables throughout the year. Retrospective registry study on trauma admissions in the 10-year period 2001-2010 at Oslo University Hospital, Ullevål, Norway, where the amount of daylight varies from less than 6 hours to almost 19 hours per day throughout the year. Daily number of admissions was analysed by fitting non-linear Poisson time series regression models, simultaneously adjusting for several layers of temporal patterns, including a non-linear long-term trend and both seasonal and weekly cyclic effects. Five daylight and weather variables were explored, including hours of daylight and amount of precipitation. Models were compared using Akaike's Information Criterion (AIC). A regression model including daylight and weather variables significantly outperformed a traditional seasonality model in terms of AIC. A cyclic week effect was significant in all models. Daylight and weather variables are better predictors of seasonality in daily trauma admissions than mere information on day-of-year.

  8. Seasonality in trauma admissions – Are daylight and weather variables better predictors than general cyclic effects?

    Science.gov (United States)

    Søvik, Signe; Eken, Torsten

    2018-01-01

    Background Trauma is a leading global cause of death, and predicting the burden of trauma admissions is vital for good planning of trauma care. Seasonality in trauma admissions has been found in several studies. Seasonal fluctuations in daylight hours, temperature and weather affect social and cultural practices but also individual neuroendocrine rhythms that may ultimately modify behaviour and potentially predispose to trauma. The aim of the present study was to explore to what extent the observed seasonality in daily trauma admissions could be explained by changes in daylight and weather variables throughout the year. Methods Retrospective registry study on trauma admissions in the 10-year period 2001–2010 at Oslo University Hospital, Ullevål, Norway, where the amount of daylight varies from less than 6 hours to almost 19 hours per day throughout the year. Daily number of admissions was analysed by fitting non-linear Poisson time series regression models, simultaneously adjusting for several layers of temporal patterns, including a non-linear long-term trend and both seasonal and weekly cyclic effects. Five daylight and weather variables were explored, including hours of daylight and amount of precipitation. Models were compared using Akaike’s Information Criterion (AIC). Results A regression model including daylight and weather variables significantly outperformed a traditional seasonality model in terms of AIC. A cyclic week effect was significant in all models. Conclusion Daylight and weather variables are better predictors of seasonality in daily trauma admissions than mere information on day-of-year. PMID:29425210

  9. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy—Use of Greenhouses and Artificial Light Sources

    Directory of Open Access Journals (Sweden)

    Catharina M. Lerche

    2016-02-01

    Full Text Available Daylight-mediated photodynamic therapy (daylight PDT is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor “daylight PDT” and investigated their ability to photobleach protoporphyrin IX (PpIX. Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector, white light-emitting diode (LED lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB radiation passes through the greenhouse glass, so sun protection is not needed.

  10. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy—Use of Greenhouses and Artificial Light Sources

    DEFF Research Database (Denmark)

    Lerche, Catharina; Heerfordt, Ida M; Heydenreich, Jakob

    2016-01-01

    to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light...... was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation...

  11. Performance of a daylight redirecting glass shading system demonstration in an office building

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend; Traberg-Borup, Steen

    2011-01-01

    This paper evaluates the daylighting performance of a prototype external dynamic integrated shading and light redirecting system. The demonstration project was carried out on a building with an open-plan office. The prototype and original façades were placed on the same floor with the same...... orientation and similar surroundings. The existing façade was used as the reference for measurements and simulations. The focus of this research project was to employ available simulation tools for the system performance evaluation. This was accompanied by measurements of the daylight conditions...... in the investigated space. The prototype system improved daylighting conditions compared to the existing shading system....

  12. Fatal alcohol-related traffic crashes increase subsequent to changes to and from daylight savings time.

    Science.gov (United States)

    Hicks, G J; Davis, J W; Hicks, R A

    1998-06-01

    On the hypothesis that sleepiness and alcohol interact to increase the risk of alcohol-related traffic fatalities, the percentages of alcohol-related fatal traffic crashes were assessed for the entire state of New Mexico for the years 1989-1992, for each of the seven days that preceded the changes to and from Daylight Savings Time and for each of the 14 days which followed the changes to and from Daylight Savings Time. Consistent with our hypothesis the percentage of alcohol-related fatal crashes increased significantly during the first seven days after these changes in Daylight Savings Time.

  13. Theoretical and experimental analysis of daylight performance for various shading systems

    Energy Technology Data Exchange (ETDEWEB)

    Tsangrassoulis, A [Group Building Enviromental Studies, Lab. of Meteorology, Dept. of Applied Physics, Univ. of Athens (Greece); Santamouris, M [Group Building Enviromental Studies, Lab. of Meteorology, Dept. of Applied Physics, Univ. of Athens (Greece); Asimakopoulos, D [Group Building Enviromental Studies, Lab. of Meteorology, Dept. of Applied Physics, Univ. of Athens (Greece)

    1997-12-31

    The daylight coefficient approach is used for the theoretical analysis of various shading systems. Once a set of these coefficients has been calculated, it is very easy to calculate illuminance in the interior of a room under various sky luminance distributions. The present paper examines a method based on daylight coefficients to evaluate daylight in the interior of a room. The method is compared with existing radiosity and ray-tracing methods. The examined method is experimentaly validated using measurements obtained in a PASSYS test-cell equipped with shading devices. (orig.)

  14. IEA Task 31. Daylighting Buildings in the 21{sup st} Century

    Energy Technology Data Exchange (ETDEWEB)

    Scartezzini, J.-L.; Morel, N.; Andersen, M.; Lindelhoef, D.

    2006-02-15

    This report for the Swiss Federal Office of Energy (SFOE) takes a look at work being carried out within the framework of the International Energy Agency's Solar Heating and Cooling Programme, Task 31 concerning the daylighting of buildings. Research activities in the task's four subtasks, user perspectives and requirements, integration and optimisation of daylighting systems, daylighting design tools and performance tracking network and design support groups are reported on. Objectives, projects and outcomes of each subtask are presented. Swiss contributions to the work done in these subtasks are reviewed and main achievements due to Swiss contributions are listed. Practical examples are quoted.

  15. Neural correlates of the natural observation of an emotionally loaded video.

    Directory of Open Access Journals (Sweden)

    Melanni Nanni

    Full Text Available Studies based on a paradigm of free or natural viewing have revealed characteristics that allow us to know how the brain processes stimuli within a natural environment. This method has been little used to study brain function. With a connectivity approach, we examine the processing of emotions using an exploratory method to analyze functional magnetic resonance imaging (fMRI data. This research describes our approach to modeling stress paradigms suitable for neuroimaging environments. We showed a short film (4.54 minutes with high negative emotional valence and high arousal content to 24 healthy male subjects (36.42 years old; SD = 12.14 during fMRI. Independent component analysis (ICA was used to identify networks based on spatial statistical independence. Through this analysis we identified the sensorimotor system and its influence on the dorsal attention and default-mode networks, which in turn have reciprocal activity and modulate networks described as emotional.

  16. Contribution of natural ventilation in a double skin envelope to heating load reduction in winter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu-Min; Sohn, Jang-Yeul [Department of Architectural Engineering, Hanyang University, Seoul (Korea); Kim, Soo-Young [Department of Housing and Interior Design, Yonsei University, Seoul (Korea); Shin, Sung-Woo [Department of Architectural Engineering, Hanyang University, Ansan (Korea)

    2009-11-15

    This study examined the contribution of a double skin envelope (DSE) to the heating energy savings brought about by natural ventilation in office buildings. A DSE was applied to the east- and west-facing walls on an actual three-floor building. Field measurements and computer simulations were performed in winter. The results implied that the DSE on the west-facing wall contributed to energy savings when natural ventilation was supplied from the cavity to the indoor space. The DSE facing east was not recommended for energy savings by natural ventilation because of its smaller exposure to solar irradiance. Multiple linear regression models were developed based on field measurements to predict the temperature variation in the cavities, and effective control logics will be discussed in a future study. Of all variables, the outdoor air temperature was the most significant factor influencing the air temperature in the cavity. Computer simulation indicated that the air in the cavity was heated to the required temperature without consuming additional energy when the ratio of the diffused irradiance to global irradiance was smaller than 0.69. The cavity in the DSE worked as a thermal buffer zone and contributed to reducing heating energy consumption by 14.71% in January. (author)

  17. Transient effects of sudden changes of heat load in a naturally ventilated room

    Science.gov (United States)

    Caulfield, C. P.; Bower, D. J.; Fitzgerald, S.; Woods, A. W.

    2006-11-01

    Using reduced numerical models and small-scale laboratory experiments, we investigate the transient effects of changing isolated heat loads discontinuously within a large, ventilated space. We consider the emptying filling box (with high and low openings) driven by a single isolated source of buoyancy. The original steady state consists of a buoyant layer, whose depth (for the simplest case of a point source plume) is determined by the geometric properties of the room alone. When the buoyancy flux of the source is increased, a new layer `fills' the room from the top with a more buoyant layer. The original layer disappears due to entrainment by the rising plume. The behaviour is qualitatively different when the source buoyancy flux is decreased. In this case, the rising plume fluid is now relatively dense, and so it inevitably collapses back to `intrude' below the original layer. In this case, the original layer disappears due to both draining through the upper opening, and penetrative entrainment by the dense plume. We compare the predictions of three numerical models using different penetrative entrainment parametrizations to a sequence of laboratory experiments. This entrainment reduces the density of the intruding layer, and so the rising plume eventually stalls, and no longer reaches the (draining) original layer. We demonstrate that it is necessary to consider the transient effects of penetrative entrainment when the reduction in source buoyancy flux is sufficiently small.

  18. A simple tool to evaluate the effect of the urban canyon on daylight level and energy demand in the early stages of building design

    DEFF Research Database (Denmark)

    Petersen, Steffen; Momme, Amalie Jin; Hviid, Christian Anker

    2014-01-01

    Daylight is a restricted resource in urban contexts. Rooms situated in an urban context often have a significant proportion of the sky and the sun blocked out by the urban building mass. The reduced direct daylight potential makes daylight reflected from outdoor surfaces an important daylight sou...... the impact of urban canyon parameters on indoor environment and energy performance....

  19. Workshop report and proposal for a new IEA Task: Daylight in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, P E; Johnsen, K

    1994-04-01

    The IEA workshop on Daylight in Buildings was held in Copenhagen on March 14-16, 1994. At the workshop, presentations were given on key topics as a basis for discussions by the experts participating in the meeting. The presentations and discussions covered a range of technical, architectural and amenity aspects of daylighting in buildings. A great interest in research collaboration on daylight was expressed, and it was agreed that plenty of work still needs to be done, and that the appropriate form of work would be an IEA Task. It was agreed that daylighting systems and control strategies should be evaluated and tested in test rooms, as well as in existing buildings as case studies. Furthermore, the workshop expressed that one of the best ways to realize and present the Task results to practice would be through a few demonstration buildings, build in different countries and under different climatic conditions. (EG)

  20. External perforated Solar Screens for daylighting in residential desert buildings: Identification of minimum perforation percentages

    KAUST Repository

    Sherif, Ahmed; Sabry, Hanan; Rakha, Tarek

    2012-01-01

    and Saudi Arabia, result in the admittance of direct solar radiation, which leads to thermal discomfort and the incidence of undesired glare. One type of shading systems that is used to permit daylight while controlling solar penetration is " Solar Screens

  1. Estimation of luminous efficacy of daylight and illuminance for composite climate

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Jamil M.; Tiwari, G.N. [Center for Energy Studies, Indian Institute of Technology, Hauz Khas, New Delhi-16 (India)

    2010-07-01

    This Daylighting is one of the basic components of passive solar building design and its estimation is essential. In India there are a few available data of measured illuminance as in many regions of the world. The Indian climate is generally clear with overcast conditions prevailing through the months of July to September, which provides good potential to daylighting in buildings. Therefore, an analytical model that would encompass the weather conditions of New Delhi was selected. Hourly exterior horizontal and slope daylight availability has been estimated for New Delhi using daylight modeling techniques based on solar radiation data. A model to estimate interior illuminance was investigated and validated using experimental hourly inside illuminance data of an existing skylight integrated vault roof mud house in composite climate of New Delhi. The interior illuminance model was found in good agreement with experimental value of interior illuminance.

  2. Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D. B.; Hadley, S. W.; Chin, S-M.

    2008-10-01

    The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called for the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings

  3. Refractive integrated nonimaging solar collectors design and analysis of a novel solar-daylighting-technology

    OpenAIRE

    Pelegrini, Alexandre Vieira

    2009-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. A novel and original category of low-cost static solar-daylighting-collectors named Keywo solar energy, solar collectors, daylighting systems, nonimaging optics, Refractive Integrated Nonimaging Solar Collectors (RINSC) has been designed and thoroughly tested. The RINSC category is based on nonimaging optics and integrates several optical elements, such as prismatic arrays and light guides, i...

  4. Delight2 Daylighting Analysis in Energy Plus: Integration and Preliminary User Results

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, William L.; Hitchcock, Robert J.

    2005-04-26

    DElight is a simulation engine for daylight and electric lighting system analysis in buildings. DElight calculates interior illuminance levels from daylight, and the subsequent contribution required from electric lighting to meet a desired interior illuminance. DElight has been specifically designed to integrate with building thermal simulation tools. This paper updates the DElight capability set, the status of integration into the simulation tool EnergyPlus, and describes a sample analysis of a simple model from the user perspective.

  5. Impact of daylight saving time on the Chilean residential consumption

    International Nuclear Information System (INIS)

    Verdejo, Humberto; Becker, Cristhian; Echiburu, Diego; Escudero, William; Fucks, Emiliano

    2016-01-01

    Since 1970 Chile has had a Daylight Saving Time (DST) policy in order to reduce residential electricity consumption in the country. The time change was set for the first time by executive decree in 1970, and since that date it was applied every year without great changes until 2010. Since then, and to date, decrees have been set in order to increase the duration of the DST, arguing that there are reasons associated with energy savings that justify the extension of the measure that has been adopted by the authority in recent years. In the present study the impact of the application of DST in terms of decreased household electricity consumption is analyzed using two complementary methods, one based on a heuristic approach and the other using an econometric model. The results indicate that there is indeed a marginally small reduction in residential electricity consumption, although these results are not homogeneous throughout the country. - Highlights: • The impact of the application of DST is analyzed in Chilean distribution networks. • The results indicate that there is indeed a marginally small reduction in residential electricity consumption. • A total energy reduction is estimated based on the proposed methodology.

  6. Daylight-mediated photodynamic therapy in Spain: advantages and disadvantages.

    Science.gov (United States)

    Pérez-Pérez, L; García-Gavín, J; Gilaberte, Y

    2014-09-01

    Photodynamic therapy (PDT) is an option for the treatment of actinic keratosis, Bowen disease, and certain types of basal cell carcinoma. It is also used to treat various other types of skin condition, including inflammatory and infectious disorders. The main disadvantages of PDT are the time it takes to administer (both for the patient and for health professionals) and the pain associated with treatment. Daylight-mediated PDT has recently been reported to be an alternative to the conventional approach. Several studies have shown it to be similar in efficacy to and better tolerated than classic PDT for the treatment of mild to moderate actinic keratosis. Nevertheless, most of these studies are from northern Europe, and no data have been reported from southern Europe. The present article reviews the main studies published to date, presents the treatment protocol, and summarizes our experience with a group of treated patients. Copyright © 2013 Elsevier España, S.L.U. y AEDV. All rights reserved.

  7. Combining annual daylight simulation with photobiology data to assess the relative circadian efficacy of interior spaces

    Energy Technology Data Exchange (ETDEWEB)

    Pechacek, C.S.; Andersen, M. [Massachusetts Inst. of Technology, Cambridge, MA (United States). Dept. of Architecture, Building Technology; Lockley, S.W. [Harvard Medical School, Boston, MA (United States). Div. of Sleep Medicine, Brigham and Women' s Hospital

    2008-07-01

    This paper addressed the issue of hospital design and the role of daylight in patient health care. It presented a new approach for integrating empirical data and findings in photobiology into the performance assessment of a space, thus combining both visual and health-related criteria. Previous studies have reported significant health care outcomes in daylit environments, although the mechanism and photoreceptor systems controlling these effects remain unknown. This study focused on furthering the previous studies beyond windows to describing the characteristics of daylight that may promote human health by providing daylighting for the appropriate synchronization of circadian rhythms, and then make specific daylighting recommendations, grounded in biological findings. In particular, this study investigated the use of daylight autonomy (DA) to simulate the probabilistic and temporal potential of daylight for human health needs. Results of photobiology research were used to define threshold values for lighting, which were then used as goals for simulations. These goals included spectrum, intensity and timing of light at the human eye. The study investigated the variability of key architectural decisions in hospital room design to determine their influence on achieving the goals. The simulations showed how choices in building orientation, window size, user-window position and interior finishes affect the circadian efficacy of a space. Design decisions can improve or degrade the health potential for the space considered. While the findings in this research were specific to hospitals, the results can be applied to other building types such as office buildings and residences. 33 refs., 7 figs.

  8. Performance of Anidolic Daylighting Systems in tropical climates - Parametric studies for identification of main influencing factors

    Energy Technology Data Exchange (ETDEWEB)

    Linhart, Friedrich; Scartezzini, Jean-Louis [Solar Energy and Building Physics Laboratory (LESO-PB), Swiss Federal Institute of Technology in Lausanne (EPFL), 1015 Lausanne (Switzerland); Wittkopf, Stephen K. [School of Design and Environment, Department of Architecture, National University of Singapore, 4 Architecture Drive, Singapore 117566 (Singapore)

    2010-07-15

    Making daylight more available in buildings is highly desirable, not only for reasons of energy-efficiency, but also for improvement of occupants' health and well-being. Core-daylighting, that is daylight provision in areas situated at considerable distances from facades and windows, is currently one of the main challenges in sustainable building design. Anidolic Daylighting Systems (ADSs) are one very promising technology in the field of core-daylighting, but commercial solutions that are not only well-performing but also financially competitive are not yet widely available. This article presents results of parametric studies on Anidolic Integrated Ceilings (AICs), a special type of ADS, for identification of main influencing factors. The article describes a reliable method for simulating ADS and AIC performance under given sky conditions. Various simulation results for the example location Singapore are discussed in detail, it is concluded that the main influencing factors are coating material, system dimensions and external obstruction, and those influencing factors' potential impacts are quantified. It is shown that AIC overall efficiencies can reach up to almost 50% in Singapore. The essentially new results presented in this article can be of great help to architects, engineers and scientists in the future, when it comes to precisely dimensioning ADS for various buildings and daylight conditions. (author)

  9. Flat Optical Fiber Daylighting System with Lateral Displacement Sun-Tracking Mechanism for Indoor Lighting

    Directory of Open Access Journals (Sweden)

    Ngoc Hai Vu

    2017-10-01

    Full Text Available An essential impact which can improve the indoor environment and save on power consumption for artificial lighting is utilization of daylight. Optical fiber daylighting technology offers a way to use direct daylight for remote spaces in a building. However, the existing paradigm based on the precise orientation of sunlight concentrator toward the Sun is very costly and difficult to install on the roof of buildings. Here, we explore an alternative approach using mirror-coated lens array and planar waveguide to develop a flat optical fiber daylighting system (optical fiber daylighting panel with lateral displacement Sun-tracking mechanism. Sunlight collected and reflected by each mirror-coated lens in a rectangular lens array is coupled into a planar waveguide using cone prisms placed at each lens focus. This geometry yields a thin, flat profile for Sunlight concentrator. Our proposed concentrating panel can be achieved with 35 mm thickness while the concentrator’s width and length are 500 mm × 500 mm. The commercial optical simulation tool (LightToolsTM was used to develop the simulation models and analyze the system performance. Simulation results based on the designed system demonstrated an optical efficiency of 51.4% at a concentration ratio of 125. The system can support utilizing a lateral displacement Sun-tracking system, which allows for replacing bulky and robust conventional rotational Sun-tracking systems. This study shows a feasibility of a compact and inexpensive optical fiber daylighting system to be installed on the roof of buildings.

  10. The performance of BAF using natural zeolite as filter media under conditions of low temperature and ammonium shock load

    International Nuclear Information System (INIS)

    He Shengbing; Xue Gang; Kong Hainan

    2007-01-01

    Natural zeolite and expanded clay were used as filter media for biological aerated filter (BAF) to treat municipal wastewater in parallel in whole three test stages. The stage one test results revealed that zeolite BAF and expanded clay BAF have COD and NH 3 -N removals in the range of 84.63-93.11%, 85.74-96.26%, 82.34-93.71%, and 85.06-93.2%, respectively, under the conditions of water temperature of 20-25 deg. C and hydraulic load of 2-3 m 3 /(m 2 h). At the following stage two, the influent NH 3 -N concentration was increased to about double value of the stage one, and it was investigated that the effluent NH 3 -N of expanded clay BAF increased significantly and then gradually restored to normal condition in 2 weeks, while the effluent NH 3 -N of zeolite BAF kept stable. At stage three, the low reactor temperature has also different effects on these two BAFs, under conditions of water temperature of 7-10 deg. C, hydraulic load of 2-3 m 3 /(m 2 h), zeolite BAF and expanded clay BAF have COD and NH 3 -N removals in the range of 74.5-88.47% (average of 81.57%), 71.73-88.49% (average of 81.06%), 71.91-87.76% (average of 80.49%), and 38.41-77.17% (average of 65.42%), respectively. Three stages test results indicated that the zeolite BAF has a stronger adaptability to NH 3 -N shock load and low temperature compared to expanded clay BAF. In addition, the detection of the amounts of heterobacteria and nitrobacteria of two biological aerated filters in three stages also showed the zeolite filter media was more suitable to the attached growth of nitrobacteria, which is helpful to the improvement of nitrification performance in zeolite BAF

  11. New Biofunctional Loading of Natural Antimicrobial Agent in Biodegradable Polymeric Films for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Bakhtawar Ghafoor

    2016-01-01

    Full Text Available The study focuses on the development of novel Aloe vera based polymeric composite films and antimicrobial suture coatings. Polyvinyl alcohol (PVA, a synthetic biocompatible and biodegradable polymer, was combined with Aloe vera, a natural herb used for soothing burning effects and cosmetic purposes. The properties of these two materials were combined together to get additional benefits such as wound healing and prevention of surgical site infections. PVA and Aloe vera were mixed in a fixed quantity to produce polymer based films. The films were screened for antibacterial and antifungal activity against bacterial (E. coli, P. aeruginosa and fungal strains (Aspergillus flavus and Aspergillus tubingensis screened. Aloe vera based PVA films showed antimicrobial activity against all the strains; the lowest Aloe vera concentration (5% showed the highest activity against all the strains. In vitro degradation and release profile of these films was also evaluated. The coating for sutures was prepared, in vitro antibacterial tests of these coated sutures were carried out, and later on in vivo studies of these coated sutures were also performed. The results showed that sutures coated with Aloe vera/PVA coating solution have antibacterial effects and thus have the potential to be used in the prevention of surgical site infections and Aloe vera/PVA based films have the potential to be used for wound healing purposes.

  12. Dental prostheses mimic the natural enamel behavior under functional loading: A review article

    Directory of Open Access Journals (Sweden)

    Ahmed A. Madfa

    2016-02-01

    Full Text Available Alumina- and zirconia-based ceramic dental restorations are designed to repair functionality as well as esthetics of the failed teeth. However, these materials exhibited several performance deficiencies such as fracture, poor esthetic properties of ceramic cores (particularly zirconia cores, and difficulty in accomplishing a strong ceramic–resin-based cement bond. Therefore, improving the mechanical properties of these ceramic materials is of great interest in a wide range of disciplines. Consequently, spatial gradients in surface composition and structure can improve the mechanical integrity of ceramic dental restorations. Thus, this article reviews the current status of the functionally graded dental prostheses inspired by the dentino-enamel junction (DEJ structures and the linear gradation in Young's modulus of the DEJ, as a new material design approach, to improve the performance compared to traditional dental prostheses. This is a remarkable example of nature's ability to engineer functionally graded dental prostheses. The current article opens a new avenue for recent researches aimed at the further development of new ceramic dental restorations for improving their clinical durability.

  13. Functionalized antibiofilm thin coatings based on PLA–PVA microspheres loaded with usnic acid natural compounds fabricated by MAPLE

    Energy Technology Data Exchange (ETDEWEB)

    Grumezescu, Valentina [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, PO Box MG-36, Bucharest-Magurele, Bucharest (Romania); University Politehnica of Bucharest, Faculty of Applied Chemistry and Materials Science, Department of Science and Engineering of Oxidic Materials and Nanomaterials, Polizu Street no 1-7, 011061 Bucharest (Romania); Socol, Gabriel [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, PO Box MG-36, Bucharest-Magurele, Bucharest (Romania); Grumezescu, Alexandru Mihai, E-mail: grumezescu@yahoo.com [University Politehnica of Bucharest, Faculty of Applied Chemistry and Materials Science, Department of Science and Engineering of Oxidic Materials and Nanomaterials, Polizu Street no 1-7, 011061 Bucharest (Romania); Holban, Alina Maria [Faculty of Biology, University of Bucharest, Microbiology Immunology Department, Aleea Portocalelor 1-3, Sector 5, 77206 Bucharest (Romania); Ficai, Anton [University Politehnica of Bucharest, Faculty of Applied Chemistry and Materials Science, Department of Science and Engineering of Oxidic Materials and Nanomaterials, Polizu Street no 1-7, 011061 Bucharest (Romania); Truşcǎ, Roxana [S.C. Metav-CD S.A., 31Rosetti Str., 020015 Bucharest (Romania); Bleotu, Coralia [Stefan S Nicolau Institute of Virology, Bucharest (Romania); Balaure, Paul Cǎtǎlin [Department of Organic Chemistry, Faculty of Applied Chemistry and Materials Science, Politehnica Universitiy of Bucharest, Polizu Street no 1-7, 011061 Bucharest (Romania); Cristescu, Rodica [National Institute for Lasers, Plasma and Radiation Physics, Lasers Department, PO Box MG-36, Bucharest-Magurele, Bucharest (Romania); Chifiriuc, Mariana Carmen [Faculty of Biology, University of Bucharest, Microbiology Immunology Department, Aleea Portocalelor 1-3, Sector 5, 77206 Bucharest (Romania)

    2014-05-01

    We report the fabrication of thin coatings of PLA–PVA microspheres loaded with usnic acid by matrix assisted pulsed laser evaporation (MAPLE) onto Ti substrate. The obtained coatings have been physico-chemically characterized by scanning electron microscopy (SEM) and infrared microscopy (IRM). In vitro biological assays have been performed in order to evaluate the influence of fabricated microsphere thin coatings on the Staphylococcus aureus biofilm development as well as their biocompatibility. SEM micrographs have revealed a uniform morphology of thin coatings, while IRM investigations have proved both the homogeneity and functional groups integrity of prepared thin coatings. The obtained microsphere-based thin coatings have proved to be efficient vehicles for usnic acid natural compound with antibiofilm activity, as demonstrated by the inhibitory activity on S. aureus mature biofilm development, opening new perspectives for the prevention and therapy associated to biofilm related infections.

  14. Dynamics of CD4 Lymphocytes and Viral Load at the Natural History of Perinatal HIV-infection

    Directory of Open Access Journals (Sweden)

    T. A. Daminov

    2015-01-01

    Full Text Available This article presents the analysis of indicators of CD4 lymphocyte count and viral load in the natural history (in the absence of ART in perinatally HIV-infected children. It was revealed that perinatal way of transmission is characterized by a higher rate of immunodeficiency progression. It may be associated with intrauterine infection, as well as an early defeat HIV immature immune system of the child. The concentration of virus in perinatally infected children since the beginning of the observation and in 30 months after infection is more than in parenterally infected children in 5 and 2 times, respectively, which determines a infavourable version of the disease in perinatally infected children.

  15. Parasite load in the blood and skin of dogs naturally infected by Leishmania infantum is correlated with their capacity to infect sand fly vectors.

    Science.gov (United States)

    Borja, Lairton Souza; Sousa, Orlando Marcos Farias de; Solcà, Manuela da Silva; Bastos, Leila Andrade; Bordoni, Marcelo; Magalhães, Jairo Torres; Larangeira, Daniela Farias; Barrouin-Melo, Stella Maria; Fraga, Deborah Bittencourt Mothé; Veras, Patrícia Sampaio Tavares

    2016-10-15

    The sand fly Lutzomyia longipalpis is primarily responsible for the transmission of visceral leishmaniasis (VL) in the New World, and dogs are considered to be the main urban reservoir of this disease. In order to improve the efficacy of control measures, it is essential to assess the transmission capacity of Leishmania infantum to the sand fly vector by naturally infected dogs. The present study investigated the existence of correlations between canine clinical presentation and the intensity of parasite load in the blood, skin and spleen of naturally infected dogs. In addition, we also attempted to establish correlations between the intensity of parasite load in canine tissue and the parasite load detected in sandflies five days after feeding on naturally infected dogs. A total of 23 dogs were examined and classified according to clinical manifestation of canine VL. Blood samples, splenic aspirate and skin biopsies were collected and parasite DNA was quantified by qPCR. Canine capacity to infect Lu. longipalpis with parasites was evaluated by xenodiagnosis and parasite loads were measured five days after feeding. No significant differences were observed with respect to canine clinical manifestation and the parasite loads detected in the blood, skin and spleen samples obtained from naturally infected dogs. Regardless of clinical canine visceral leishmaniasis (CVL) presentation and the degree of parasite burden, almost half of the dogs successfully infected sandflies with parasites, albeit to a low number of sandflies with correspondingly low parasite loads. Parasite loads in both canine blood and skin were shown to be positively correlated with the canine infectiousness to the sand fly vector, and positive correlations were also observed with respect to these tissues and the sand fly infection rate, as well as the parasite load detected in sandflies following xenodiagnosis. In conclusion, this indicates that parasite loads in both blood and skin can function as

  16. Evening daylight may cause adolescents to sleep less in spring than in winter

    Science.gov (United States)

    Figueiro, Mariana G.; Rea, Mark S.

    2012-01-01

    Sleep restriction commonly experienced by adolescents can stem from greater sleep pressure by the homeostatic processes and from phase delays of the circadian system. With regard to the latter potential cause, we hypothesized that because there is more natural evening light during the spring than winter, a sample of adolescent students would be more phase delayed in spring than in winter, would have later sleep onset times and, because of fixed school schedules, would have shorter sleep durations. Sixteen eighth-grade subjects were recruited for the study. We collected sleep logs and saliva samples to determine their dim light melatonin onset (DLMO), a well-established circadian marker. Actual circadian light exposures experienced by a subset of twelve subjects over the course of seven days in winter and in spring using a personal, head-worn, circadian light measurement device are also reported here. Results showed that this sample of adolescents was exposed to significantly more circadian light in spring than in winter, especially in the evening hours when light exposure would likely delay circadian phase. Consistent with the light data, DLMO and sleep onset times were significantly more delayed, and sleep durations were significantly shorter in spring than in winter. The present ecological study of light, circadian phase, and self-reported sleep suggests that greater access to evening daylight in the spring may lead to sleep restriction in adolescents while attending school. Therefore, lighting schemes that reduce evening light in the spring may encourage longer sleep times in adolescents. PMID:20653452

  17. Daylight Management in Mediterranean Cities: When Shortage Is Not the Issue

    Directory of Open Access Journals (Sweden)

    Judit Lopez-Besora

    2016-09-01

    Full Text Available Natural resources such as daylight and sunlight are highly appreciated in countries with prevailing overcast skies. Taking advantage of this scarce resource contributes to saving energy on artificial lighting. In contrast to northern, southern European cities are distinguished by a large number of days with direct sunlight caused by a propitious climate condition. While it is a positive issue in terms of energy availability, the abundance of it can be counterproductive if management measures are not taken. Apart from the thermal consequences, lighting penetration into buildings causes a great contrast between inside and outside. This is especially critical when the visual system does not have enough time to adapt, as happens at entrance areas. The aim of this study is to analyze the light contrast between these areas and the urban outside in sunny conditions. To attain this objective, light data from five entrance spaces and their contiguous streets were analyzed and measured. The results were divided into three zones in the visual scene, showing an increasing contrast from top to bottom of the visual field. It may be concluded that interventions applied to urban areas and building pavements can improve visual adaptation in the transition zone.

  18. Low cost data acquisition module for evaluating the quantitative performance of daylight systems

    Energy Technology Data Exchange (ETDEWEB)

    Ciampini, F.; Scarazzato, P.S. [Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, P.O. Box 6021, CEP 13083-852 Campinas (Brazil); Neves, A.A.R. [Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin, Departamento de Eletronica Quantica, P.O. Box 6165, 13083-970 Campinas (Brazil); Pereira, D.C.L.; Yamanaka, M.H. [Universidade de Sao Paulo, Faculdade de Arquitetura e Urbanismo, Departamento de Tecnologia da Arquitetura, Rua do Lago, 878 CEP 05508-080, Sao Paulo (Brazil)

    2007-09-15

    The search for efficient, auto-sustainable constructions that allows the user a contact with the outer environment has stimulated the development of advanced strategies, in various devices, for the exploitation of the daylight. A low cost data acquisition system was developed in this study, to observe the distribution of the natural light inside a prototype and to evaluate the quantitative performance for redirecting systems. The luminous sensor is a light dependent resistor, that responds to the illuminance with a reduction in the resistance when illuminated, through a log-log dependence. Calibration curves are set up to relate the change of resistance to absolute illuminance. It therefore provides a continuous investigation of the illuminance for various sampled points in the interior test space with a 0.03% digital error due to the 12-bit resolution. The final measured error of 5% is mainly due to the system calibration and resistance memory history. The circuit connects to a standard parallel port of any Personal Computer and supplies 64 analog inputs, one for each luminous sensor. The circuit can be easily modified to attend different quantities of analog inputs or communication ports. (author)

  19. The effect of fibre layering pattern in resisting bending loads of natural fibre-based hybrid composite materials

    Directory of Open Access Journals (Sweden)

    Jusoh Muhamad Shahirul Mat

    2016-01-01

    Full Text Available The effect of fibre layering pattern and hybridization on the flexural properties of composite hybrid laminates between natural fibres of basalt, jute and flax with synthetic fibre of E-glass reinforced epoxy have been investigated experimentally. Results showed that the effect fibre layering pattern was highly significant on the flexural strength and modulus, which were strongly dependent on the hybrid configuration between sandwich-like (SL and intercalation (IC sequence of fibre layers. In addition, specific modulus based on the variation densities of the hybrid laminates was used to discover the best combination either basalt, jute or flax with E-glass exhibits superior properties concerning on the strength to weight-ratio. Generally, SL sequence of glass/basalt exhibited superior strength and stiffness compared with glass/jute and glass/flax in resisting bending loads. In terms of hybridization effect, glass/jute was found to be the best combination with E-glass compared to the rest of natural fibres investigated in the present study. Hence, the proper stacking sequences and material selection are among predominant factors that influence on mechanical properties and very crucial in designing composite hybrid system to meet the desired requirements.

  20. Simulation of Daylighting Conditions in a Virtual Underground City

    Directory of Open Access Journals (Sweden)

    Cristiano Merli Alcini

    2015-06-01

    Full Text Available From the Piranesi fantastic architectures to the animation movies and video games of the last thirty years, a new design approach has been introduced and developed: the design of the virtual space. Designing the "virtual" means experiencing a multidisciplinary approach where architecture, engineering, and urban planning meet the new horizons of information and communication technology. This study is focused on virtual space, which is an underground city. Mankind have always made and used underground environments: the possibilities of unlimited spaces to potential development, the reduced needs for raw materials for the construction and the protection from outdoor weather are some of the reasons that prompted humans to the realization of underground spaces in the past. These reasons and the availability of innovative technologies could encourage a breakthrough in the realization of new underground environments. A recent example is represented by the Underground City of Montreal (RÉSO. We present the architectural design of a virtual underground city, which is called Arch[ane], and its evaluation. The underground city is modular and the studied module is composed of eight floors with a total depth of 400 m and dimensions of 800 m × 800 m. The study comprises the evaluation of the effect of sunlight on each eight floors of the city. Daylighting simulations were performed considering different cities at different latitudes, days, and hours. The results have shown that the particular design of the underground city with skylights gives significant values of illuminance at a certain depth. Furthermore, the simulation results show how huge can be the potentialities of software to simulate extremely big environments.

  1. A randomized, multicentre study of directed daylight exposure times of 11/2 vs. 21/2 h in daylight-mediated photodynamic therapy with methyl aminolaevulinate in patients with multiple thin actinic keratoses of the face and scalp

    DEFF Research Database (Denmark)

    Wiegell, S.R.; Fabricius, S.; Philipsen, P.A.

    2011-01-01

    , time of day or time of year during which the treatment was performed. Treatment was well tolerated, with a mean ± SD maximal pain score of 1·3 ± 1·5. Conclusions: Daylight-mediated MAL-PDT is an effective, convenient and nearly pain-free treatment for patients with multiple thin AKs. Daylight-mediated......, the inconvenience of clinic attendance and discomfort during therapy are significant drawbacks. Daylight-mediated PDT could potentially reduce these and may serve as an alternative to conventional PDT. Objectives: To compare the efficacy of methyl aminolaevulinate (MAL)-PDT with 11/2 vs. 21/2 h of daylight exposure...

  2. The influence of the static wind load concept on the material requirements for reinforced-concrete natural-draught cooling towers

    International Nuclear Information System (INIS)

    Harnach, R.

    1977-01-01

    The natural wind is the decisive risk factor in natural-draught cooling towers; therefore, the establishment of an assumed velocity is indispensable for the safety and reliability of the construction. In the framework of a statistical wind concept, static substitution loads for the assumed dynamic wind pressure have been determined, also including dynamic wind effects and the resonance response of the structure. On this basis, it has been studied how wind loads with different periodicity affect the material requirements of reinforced-concrete natural-draught cooling towers. It is found that the additional steel requirements, related to the total building cost, remain within acceptable limits even for extreme wind loads. (orig.) [de

  3. Glazing façade modules : daylighting performance simulation for Bragança, Coimbra, Évora and Faro

    OpenAIRE

    Sacht, Helenice Maria; Bragança, L.; Almeida, Manuela Guedes de; Caram, Rosana

    2012-01-01

    The daylighting performance improvement is one better strategy to reduce the artificial lighting consumption in buildings and obviously requires solar radiation from the exterior. Daylighting comes not only from direct sunlight but also from illumination provided by the sky on overcast days. Particular attention must be given to daylighting while designing a building when the aim is to maximize visual comfort or to reduce energy consumption. Visual comfort of glazing façades is a fundamental ...

  4. Architecture, energy and daylight. Study of seven buildings; Arkitektur, energi og dagslys. Undersoegelse af syv bygninger

    Energy Technology Data Exchange (ETDEWEB)

    Christoffersen, J.; Petersen, E.; Svensson, O.

    2001-07-01

    The purpose of this research project was to enhance the designer's knowledge for designing buildings, rooms and window openings which utilise daylight in such a way that aesthetic and functional requirements can be met and energy consumption for electric lighting can be reduced at the same time. It was not the purpose of the project to develop guidelines but only to demonstrate how good daylight conditions and energy conservation can be achieved. The daylight conditions in the seven selected buildings were registered and assessed by the panel on two field trips in the spring of 1999. During these visits, the research team registered the location of rooms, their orientation, windows, artificial lighting etc. After the field trips, the buildings were photographed and the research group performed measurements and analyses of the lighting conditions in the rooms. However, the quality of daylight cannot be determined based only on measurements. The four professionals therefore supplemented the measurements with a subjective evaluation. The study of these seven buildings led to a number of results that must be assumed to be generally valid. A main result is that good daylight conditions in no way prevents or impedes the creation of good architecture. On the contrary, quality of daylight creates both functional as well as aesthetically satisfactory architecture. In all the investigated buildings, the ratio of glass areas to floor area is highter than 10%. In Denmark, this ratio would ensure reasonable daylight access and a view out. However, when size of glass area and daylight measurements are compared, the relationship between them is not straight-forward. The quantity and quality of daylight in buildings depend on other factors too, such as the depth of window openings, solar shading devices, opposite buildings, outdoor vegetation etc. The study points out that there are no standard solutions of how to design facades and window openings which satisfy all

  5. Daylighting performance evaluation of a bottom-up motorized roller shade

    Energy Technology Data Exchange (ETDEWEB)

    Kapsis, K.; Athienitis, A.K.; Zmeureanu, R.G. [Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, QC (Canada); Tzempelikos, A. [School of Civil Engineering, Purdue University, West Lafayette, IN (United States)

    2010-12-15

    This paper presents an experimental and simulation study for quantifying the daylighting performance of bottom-up roller shades installed in office spaces. The bottom-up shade is a motorized roller shade that opens from top to bottom operating in the opposite direction of a conventional roller shade, so as to cover the bottom part of the window, while allowing daylight to enter from the top part of the window, reaching deeper into the room. A daylighting simulation model, validated with full-scale experiments, was developed in order to establish correlations between the shade position, outdoor illuminance and work plane illuminance for different outdoor conditions. Then, a shading control algorithm was developed for application in any location and orientation. The validated model was employed for a sensitivity analysis of the impact of shade optical properties and control on the potential energy savings due to the use of daylighting. The results showed that Daylight Autonomy for the bottom-up shade is 8-58% higher compared to a conventional roller shade, with a difference of 46% further away from the facade, where the use of electric lighting is needed most of the time. The potential reduction in energy consumption for lighting is 21-41%. (author)

  6. Effectiveness of daylighting design and occupant visual satisfaction in a LEED gold laboratory building

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Ying; Oswald, Anne [Department of Design and Environmental Analysis, Cornell University, Ithaca, NY 14853 (United States); Yang, Xiaodi [School of Architecture, Carnegie Mellon University, Pittsburgh, PA 15213 (United States)

    2011-01-15

    Using daylight as primary light source has been widely recognized as an important strategy to reduce building energy demand and enhance indoor environment quality. However, to design and operate a building to make full use of daylight, which is a dynamic light source, to meet diverse occupant needs remains a challenge. This paper reports a post-occupancy study of the visual environment in a laboratory building on a university campus, and puts a spotlight on the building occupants as it examines the effectiveness of the daylighting design and systems integration in creating a visual environment to support occupant comfort and satisfaction while reducing artificial lighting demand. Results show generally high satisfaction with daylit work environment and positive effect of the horizontal shading strategy. Issues about the integration between daylighting and electric lighting systems and level of occupant control are identified and discussed for improving the effectiveness of daylighting and enhancing the quality of the visual environment in the building of study. A multiple-tool methodology is developed and tested, which included occupant surveys, interviews, illuminance measurements, continuous data loggers, fisheye-lens camera and glare-identifying software, and documentation of spatial settings, systems features, and user behavior. (author)

  7. Performance of integrated systems of automated roller shade systems and daylight responsive dimming systems

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byoung-Chul; Choi, An-Seop; Jeong, Jae-Weon [Department of Architectural Engineering, Sejong University, Kunja-Dong, Kwangjin-Gu, Seoul (Korea, Republic of); Lee, Eleanor S. [Building Technologies Department, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2011-03-15

    Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90% of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system. (author)

  8. Daylight saving time transitions and hospital treatments due to accidents or manic episodes

    Directory of Open Access Journals (Sweden)

    Lönnqvist Jouko

    2008-02-01

    Full Text Available Abstract Background Daylight saving time affects millions of people annually but its impacts are still widely unknown. Sleep deprivation and the change of circadian rhythm can trigger mental illness and cause higher accident rates. Transitions into and out of daylight saving time changes the circadian rhythm and may cause sleep deprivation. Thus it seems plausible that the prevalence of accidents and/or manic episodes may be higher after transition into and out of daylight saving time. The aim of this study was to explore the effects of transitions into and out of daylight saving time on the incidence of accidents and manic episodes in the Finnish population during the years of 1987 to 2003. Methods The nationwide data were derived from the Finnish Hospital Discharge Register. From the register we obtained the information about the hospital-treated accidents and manic episodes during two weeks before and two weeks after the transitions in 1987–2003. Results The results were negative, as the transitions into or out of daylight saving time had no significant effect on the incidence of accidents or manic episodes. Conclusion One-hour transitions do not increase the incidence of manic episodes or accidents which require hospital treatment.

  9. Daylight saving time transitions and hospital treatments due to accidents or manic episodes

    Science.gov (United States)

    Lahti, Tuuli A; Haukka, Jari; Lönnqvist, Jouko; Partonen, Timo

    2008-01-01

    Background Daylight saving time affects millions of people annually but its impacts are still widely unknown. Sleep deprivation and the change of circadian rhythm can trigger mental illness and cause higher accident rates. Transitions into and out of daylight saving time changes the circadian rhythm and may cause sleep deprivation. Thus it seems plausible that the prevalence of accidents and/or manic episodes may be higher after transition into and out of daylight saving time. The aim of this study was to explore the effects of transitions into and out of daylight saving time on the incidence of accidents and manic episodes in the Finnish population during the years of 1987 to 2003. Methods The nationwide data were derived from the Finnish Hospital Discharge Register. From the register we obtained the information about the hospital-treated accidents and manic episodes during two weeks before and two weeks after the transitions in 1987–2003. Results The results were negative, as the transitions into or out of daylight saving time had no significant effect on the incidence of accidents or manic episodes. Conclusion One-hour transitions do not increase the incidence of manic episodes or accidents which require hospital treatment. PMID:18302734

  10. A Study on the Optimal Duration of Daylight Saving Time (DST in Korea

    Directory of Open Access Journals (Sweden)

    Byeong-Hee Mihn

    2009-09-01

    Full Text Available Daylight saving time aims at spending effective daylight in summer season. Korea had enforced daylight saving time twelve times from 1948 to 1988. Since 1988, it is not executed, but it is recently discussed the resumption of DST. In this paper, we investigate the trend of DST in other countries, review the history of DST in Korea, and suggest the optimal DST duration in terms of astronomical aspects (times of sunrise and sunset. We find that the starting day of DST in Korea is apt for the second Sunday in Mayor the second Sunday in April according to the time of sunrise or to the difference between Korean standard meridian and observer`s, respectively. We also discuss time friction that might be caused by time difference between DST and Korea Standard Time (KST.

  11. Determining daylight and view preferences from the use of blinds in apartments

    DEFF Research Database (Denmark)

    Petersen, Mads Dines

    2015-01-01

    preferences have significant influence on the daylight level and view as well as possible impact on the building’s energy consumption. Therefore, it is important to conduct further studies in the area in order to be able to design solutions that supports the user preferences better and through that improves...... for the inhabitants’ health and well-being, as well as the energy consumption. Present research is an important contribution, because of the increased knowledge about daylights impact on health and well-being as well as daylights impact on the energy consumption in our buildings. However, it is often seen...... that curtains or blinds, often close off new apartment buildings with large glass areas in dense urban context. Such observations indicate that there can be a discrepancy between the intentions of the design team or architect and the perception of the user. The paper presents the results of observations...

  12. Solar shading for low energy use and daylight quality in offices: Simulations, measurements and design tools

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.C.

    2001-11-01

    This thesis investigates the impact of solar shading devices on energy use and daylight quality in office rooms. The impact on energy use is analysed through computer simulations with the dynamic energy simulation program Derob-LTH while the impact on daylight quality is investigated through measurements in full-scale experimental office rooms and simulations with the program Radiance. This thesis also includes a literature review of research on solar shading as well as design tools to incorporate shading devices at an early stage in the design of buildings. This thesis indicates that, in cold countries, shading devices may provide more annual energy savings than any solar-protective (reflective, tinted) glazing and that the optimum glazing transmittance is orientation- and climate-dependent. For example, high annual energy savings are obtained on the south facade with higher transmittance glazings (compared with the east and west facade) because the potential for passive solar gain utilisation in the winter is high in comparison with the annual cooling demand. Exterior shading devices like awnings and overhangs may reduce the cooling demand dramatically but they are not suitable as daylight (glare) control devices. Devices like screens and venetian blinds are preferable because they cover the entire window area, which prevents sunlight patches in the room and the direct view of the bright sky. Screens and venetian blinds also reduce daylight in the room to levels that are suitable for computer work. However, it is essential that the screen is of a diffusing type since screens with a strong (specular) transmittance component result in poor daylight quality. The study on daylight quality also indicated that a screen transmittance of around 15 % may be optimum for a standard (3.5 by 6.0 m{sup 2}) south-oriented office room with a window covering around 25 % of the facade area (12 % of the floor area)

  13. Natural compositional variation of the river Meuse (Maas) suspended load: a 13 ka bulk geochemical record from the upper Kreftenheye and Betuwe Formations in northern Limburg

    NARCIS (Netherlands)

    Tebbens, L.A.; Veldkamp, A.; Kroonenberg, S.B.

    2000-01-01

    Unambiguously pristine and largely unpolluted sediments from the Late Weichselian and Holocene infillings of the Meuse residual channels in northern Limburg (the Netherlands) have been sampled to determine the natural compositional variation of the river’s suspended load. Bulk geochemical and

  14. Singapore's Zero-Energy Building's daylight monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Grobe, Lars; Wittkopf, Stephen; Pandey, Anupama Rana; Xiaoming, Yang; Seng, Ang Kian; Scartezzini, Jean-Louis; Selkowitz, Stephen

    2010-02-28

    A setup to monitor the daylighting performance of different glazing types in Singapore is presented. The glazing is installed in the facade of four dedicated testing chambers in BCAA's Zero Energy Building in Singapore. These test rooms are equipped with sensors that both record illuminances on the work plane, and luminances as seen by occupants. The physical and logical design of the monitoring system is presented. Criteria to assess the daylighting performance are introduced, and initial results of the work in progress are presented.

  15. Estimation Methodology for the Electricity Consumption with the Daylight- and Occupancy-Controlled Artificial Lighting

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Strømberg, Ida Kristine

    2017-01-01

    Artificial lighting represents 15-30% of the total electricity consumption in buildings in Scandinavia. It is possible to avoid a large share of electricity use for lighting by application of daylight control systems for artificial lighting. Existing methodology for estimation of electricity...... consumption with application of such control systems in Norway is based on Norwegian standard NS 3031:2014 and can only provide results from a rough estimate. This paper aims to introduce a new estimation methodology for the electricity usage with the daylight- and occupancy-controlled artificial lighting...

  16. The effect of daylight saving time options on electricity consumption of Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Karasu, Servet [Rize University, Rize Vocational School, 53100, Rize (Turkey)

    2010-09-15

    Most of the developed countries in the world use Daylight Saving Time (DST) as an energy conservation method. This study focuses on the effects of DST on electrical lighting in the buildings in Turkey. Turkey might adjust its daylight saving time to decrease energy consumption. For this purpose, five scenarios are considered and compared to status quo. The scenario with a 30-minute forward shift to single DST from April to October, stands out as the best solution to conserve electricity across the entire country. The results of the study show that maximum saving is obtained in this scenario by at least 0.7% on the consumption of lighting electricity. (author)

  17. Economic feasibility of maximising daylighting of a standard office building with efficient electric lighting

    DEFF Research Database (Denmark)

    Fontoynont, Marc; Ramananarivo, Karine; Soreze, Thierry Silvio Claude

    2016-01-01

    This paper investigates the cost of developing various daylighting strategies for a standard office building in relation to their ability to reduce electric lighting consumption. The reference building design for this study corresponds to a typical configuration that minimises the construction...... costs and is typical of the French market. We have compared scenarios that entail moving service spaces to the periphery, increasing ceiling height and adding light wells of various shapes. These special features increased the proportion of the indoor area with sufficient daylight by up to 40...

  18. On the development of new SPMN diurnal video systems for daylight fireball monitoring

    Science.gov (United States)

    Madiedo, J. M.; Trigo-Rodríguez, J. M.; Castro-Tirado, A. J.

    2008-09-01

    Convenciones Ecológicas y Medioambientales (CIECEM, University of Huelva), in the environment of Doñana Natural Park (Huelva province). In this way, both stations, which are separated by a distance of 75 km, will work as a double video station system in order to provide trajectory and orbit information of mayor bolides and, thus, increase the chance of meteorite recovery in the Iberian Peninsula. The new diurnal SPMN video stations are endowed with different models of Mintron cameras (Mintron Enterprise Co., LTD). These are high-sensitivity devices that employ a colour 1/2" Sony interline transfer CCD image sensor. Aspherical lenses are attached to the video cameras in order to maximize image quality. However, the use of fast lenses is not a priority here: while most of our nocturnal cameras use f0.8 or f1.0 lenses in order to detect meteors as faint as magnitude +3, diurnal systems employ in most cases f1.4 to f2.0 lenses. Their focal length ranges from 3.8 to 12 mm to cover different atmospheric volumes. The cameras are arranged in such a way that the whole sky is monitored from every observing station. Figure 1. A daylight event recorded from Sevilla on May 26, 2008 at 4h30m05.4 +-0.1s UT. The way our diurnal video cameras work is similar to the operation of our nocturnal systems [1]. Thus, diurnal stations are automatically switched on and off at sunrise and sunset, respectively. The images taken at 25 fps and with a resolution of 720x576 pixels are continuously sent to PC computers through a video capture device. The computers run a software (UFOCapture, by SonotaCo, Japan) that automatically registers meteor trails and stores the corresponding video frames on hard disk. Besides, before the signal from the cameras reaches the computers, a video time inserter that employs a GPS device (KIWI-OSD, by PFD Systems) inserts time information on every video frame. This allows us to measure time in a precise way (about 0.01 sec.) along the whole fireball path. EPSC Abstracts

  19. Application of a spectral sky in Radiance for daylighting calculations including non-image-forming light effects

    NARCIS (Netherlands)

    Khademagha, P.; Aries, M.B.C.; Rosemann, A.L.P.; van Loenen, E.J.

    2016-01-01

    Daylight is dynamic and rich in the blue part of the spectrum. To date, the spectral composition of daylight is ignored in sky models used in Radiance. Spectral sky composition is particularly important when non-image-forming (NIF) light effects are concerned, since the action spectrum for these

  20. Distinguishing Natural and Anthropogenic Sources of Chemical Loading on a Watershed-Scale, Mill River Watershed, Massachusetts

    Science.gov (United States)

    Rhodes, A. L.; Newton, R. M.; Pufall, A.

    2001-05-01

    The Mill River Watershed (MRW), a 125 km2 catchment of the Connecticut River, possesses heterogeneous topography, geology, and human settlement patterns suitable for distinguishing natural sources of chemical loading to rivers from anthropogenic sources. The MRW is divided into catchments by drainage patterns of dominant tributaries. Catchments are further classified into land-use zones, defined by intensity of human activity. Water chemistry in Zone I areas, where human activity is minimal to absent, serves as a baseline for assessing human impacts on water quality from within the watershed. Zone II areas are primarily affected by water removal from drinking water reservoirs on two tributaries ( ~9500 m3 per day, combined). Zone III regions receive runoff from agricultural, residential, and transportation areas. Since 1997, water samples collected from 13 sites in MRW have been analyzed for specific conductance, temperature, pH, ANC, base cations (Ca, Mg, Na, K, NH4), anions (Cl, SO4, NO3, PO4), and dissolved silica. GIS software was used to calculate percent area of different land uses that drain to each sample site. For the majority of sample sites in MRW, average concentrations of both NO3 and SO4 show a positive, linear relationship with percent area of anthropogenic land (R2> 0.91). Concentrations of Cl increase linearly with road density (R2= 0.95). However, two Zone III sites receiving additional point-source pollution show higher NO3 and SO4 concentrations than predicted by land use; concentrations reflect 20 and 50% more anthropogenic area than actually exists. Removal of drinking water from the larger reservoir also produces 20 and 30% more NO3 and SO4 than predicted by land use, showing that water removal concentrates pollution. Low-gradient, Zone III sites that receive highway runoff show elevated salt concentrations that persist throughout the year. Salt-impacted regions show a strong correlation between Na and Cl (R2 = 0.86 to 0.95). Cl typically

  1. The environment of nature reserves under anthropogenic load: air transport of pollution to the North of European Russia

    Science.gov (United States)

    Vinogradova, A. A.; Ivanova, Yu. A.; Veremeychik, A. O.

    2012-04-01

    Nature reserves are created to keep in their original states natural environment, flora and fauna of various ecological systems, territories, climatic zones, etc. Now natural objects everywhere exist under anthropogenic loading from man-made activities. It is impossible to avoid atmospheric or river transport of pollution to the environment of reserved territories. The main idea of the work is to analyze atmospheric transport of anthropogenic metals (Ni, Cu, Pb, Fe, Al), as well as of soot (black carbon - BC) from Russian large industrial areas (source-regions) to the territories of nature reserves at the North of European Russia - the Kostomukshsky reserve (KR) in Karelia (64.57°N, 30.67°E) and the Nenetzky reserve (NR) at the Pechora River mouth (68,5°N, 53,5°E). The basic data for these 2 points were back trajectories of air mass transport calculated for every day of January, April, July, and October during 10 years from 2001 to 2010. We used NCEP/NCAR Reanalysis Data Files with HYSPLIT 4 model and two approaches for analyzing the trajectories. The main source-regions were chosen for each reserve. The annual source emissions for the last decade are generalized from the data published by Roshydromet of Russia (http://www.nii-atmosphere.ru/files/PUBL/Eg_2008.doc). The deposition velocity was a sum of dry and wet components. The equal values of deposition velocities onto the surface were assumed for all impurities because they are mainly on submicron aerosol particles under atmospheric transport for a long distance. The seasonal and spatial variations of averaged deposition velocity were accounted in accordance with surface properties and precipitation regimes. As a result, the maximal air concentrations of aerosol pollutants are observed in cold seasons, whereas the maximal fluxes onto the surface occur in warm period. Thus, it's possible that the cleanest air does not indicate the same surface. Fe and Al are the crust (dust or soil) elements. Thus, their main

  2. Window design : visual and thermal consequences : analysis of the thermal and daylighting performance of windows

    NARCIS (Netherlands)

    Bergem-Jansen, P.M. van; Soeleman, R.S.

    1979-01-01

    Selected results of an analysis for the thermal and lighting requirements associated with windows in utility buildings are presented. This analysis concerns the effects of r¡indow size and shape, orientation and of different ways of supplementing the daylight by artifieial light for a typical office

  3. The Dynamics of Daylighting at a Residential College Building with the Internal Courtyard Arrangement

    Directory of Open Access Journals (Sweden)

    Adi Ainurzaman Jamaludin

    2015-11-01

    Full Text Available Dayasari residential college building was designed with the internal courtyard that allows for numerous implementations of bioclimatic design strategies, especially on daylighting. The field measurement was conducted at eight unoccupied student rooms, selected as samples to represent ten scenarios and orientations that concerned with the level of radiation and penetration of sunlight. This study reveals the contribution of the internal courtyard in the residential college which allows the daylight penetration at the corridor areas and interior of the rooms through the transom over the entrance door, up to ten hours daily. Different amounts of daylight were measured in specific room scenarios to suggest on the most comfortable indoor living space. The recorded mean value for indoor varied from 37 to 286 lux, while in the corridor area 192 to 3,848 lux. However, the use of the large overhangs over the windows, wall openings in the room and trees with large canopy in the landscape setting should critically justify when the adequacy of daylight was drastically reduced in certain rooms.

  4. The characterisation of the daylighting properties of special glazings and solar shading devices

    NARCIS (Netherlands)

    Dijk, H.A.L. van; Bakker, L.G.

    1998-01-01

    Within the EU DGXII R&D Programme JOULE a project, called REVIS. started in 1998 and will be completed within 2.5 years, with the objective to develop detailed daylight product information of novel products of glazings and solar shading devices. This involves a test procedure, definition of product

  5. PULSE: Integrated Parametric Modeling for a Shading System : From Daylight Optimization to Additive Manufacturing

    NARCIS (Netherlands)

    Teeling, M.V.M.T.; Turrin, M.; de Ruiter, P.; Turrin, Michela; Peters, Brady; O'Brien, William; Stouffs, Rudi; Dogan, Timur

    2017-01-01

    This paper presents a parametric approach to an integrated and performance-oriented design, from the conceptual design phase towards materialization. The novelty occurs in the use of parametric models as a way of integrating multidisciplinary design constraints, from daylight optimization to the

  6. OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB

    Directory of Open Access Journals (Sweden)

    SIREGAR Mhd. Akbar Anthony

    2016-12-01

    Full Text Available One way to reduce energy consumption in buildings is to use daylighting. However, daylight can cause visual discomfort in the form of glare. Center of Art, Design, and Language (CADL Institut Teknologi Bandung is a building that has windows on west and east facades, so the probability of glare occurrence is high. In this research, CADL was optimized so that the percentage of time that Daylight Glare Probability below 0.21 (%DGP<0.21 is more than 50% and spatial daylight autonomy with illuminance 150 lux and 50% (sDA150lux,50% is more than 30%. In the optimization, vertical blinds, horizontal blinds, and curtains were added. Vertical blinds and horizontal blinds were varied by changing the blade’s opening angle and area covering the windows, while curtains were varied only by changing the area covering the windows. The results show that %DGP<0.21 can be increased beyond 50%, but in some rooms, sDA150,50% also decrease below 30%. The most frequent optimum solutions are vertical blinds 75%-60o.

  7. Practical approach to the use of daylight photodynamic therapy with topical methyl aminolevulinate for actinic keratosis

    DEFF Research Database (Denmark)

    Morton, C A; Wulf, H C; Szeimies, R M

    2015-01-01

    INTRODUCTION: Daylight-mediated photodynamic therapy has been shown to be an effective therapy for actinic keratoses (AKs) and a simple and tolerable treatment procedure in three randomized Scandinavian studies and two recent Phase III randomized controlled studies in Australia and Europe...

  8. A review of methods for the evaluation of the energy contribution of daylight in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Attenborough, M; Goodwin, A

    1996-07-01

    A review has been undertaken of energy prediction methods and daylight calculation methods currently in use in the UK. This was based on a literature review and discussions with large engineering practices and academics involved in the areas of daylighting and energy simulation research. The aim of this review was to identify manual methods or computer programs that are capable of determining energy use in non-domestic buildings and of taking into account the energy savings resulting from daylighting. One potential application for these methods is in supporting anticipated energy targets for non-domestic buildings within Building Regulations and other energy labelling schemes. The review has identified a range of methods which are capable of predicting overall energy use while accounting for daylight. These vary in complexity from empirical methods such as ESICHECK and the CIBSE Energy Code through to dynamic energy simulation models such as DOE 2 and ESP. For each of the methods identified a brief assessment has been made of their technical capabilities ease of use and availability. These assessments have been based on discussions with users and program developers. Descriptions of the various methods are given. (Author)

  9. Effect of daylight saving time on lighting energy use: a literature review

    NARCIS (Netherlands)

    Aries, M.B.C.; Newsham, G.R.

    2008-01-01

    The principal reason for introducing (and extending) daylight saving time (DST) was, and still is, projected energy savings, particularly for electric lighting. This paper presents a literature review concerning the effects of DST on energy use. Simple estimates suggest a reduction in national

  10. Change in the Classroom Deportment of Children Following Change From Daylight Saving Time.

    Science.gov (United States)

    Hicks, Robert A.; And Others

    1980-01-01

    The deportment of each student in a third-grade classroom was rated by the teacher before and after the fall change from daylight savings time, to see if this disruption in circadian rhythms alters behavior. The deportment of boys improved significantly while the deportment of girls was significantly disrupted. (Author/SJL)

  11. Simple tool to evaluate the impact of daylight on building energy consumption

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Nielsen, Toke Rammer; Svendsen, Svend

    2008-01-01

    This paper presents a simple building simulation tool for integrated daylight and thermal analysis. The tool is capable of importing the thermal and visual properties for different glazings and shading positions from the Window Information System (WIS) program. A coupled ray-tracing and radiosity...

  12. Simple tool to evaluate the impact of daylight on building energy consumption

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Nielsen, Toke Rammer; Svendsen, Svend

    2008-01-01

    This paper presents a simple building simulation tool for integrated daylight and thermal analysis. The tool is capable of importing the thermal and visual properties for different glazings and shading positions from the Window Information System (WIS) program. Radiosity methodology is used...

  13. 75 FR 36089 - Payment System Risk Policy; Daylight Overdraft Posting Rules

    Science.gov (United States)

    2010-06-24

    ... FEDERAL RESERVE SYSTEM [OP-1385] Payment System Risk Policy; Daylight Overdraft Posting Rules... Payment System Risk Policy, the Board is announcing posting rules for a new same-day automated clearing... Kirkpatrick, Senior Financial Services Analyst, Payment System Risk (202-452-2796), or Jennifer Davidson...

  14. 77 FR 22666 - Payment System Risk Policy; Daylight Overdraft Posting Rules

    Science.gov (United States)

    2012-04-17

    ... FEDERAL RESERVE SYSTEM 12 CFR Part 204 [Docket No. OP-1440] Payment System Risk Policy; Daylight.... SUMMARY: The Board of Governors of the Federal Reserve System (Board) has revised its Policy on Payment...), Division of Reserve Bank Operations and Payment Systems. For users of Telecommunications Device for the...

  15. 78 FR 70046 - Payment System Risk Policy; Daylight Overdraft Posting Rules

    Science.gov (United States)

    2013-11-22

    ... FEDERAL RESERVE SYSTEM [Docket No. OP--1471] Payment System Risk Policy; Daylight Overdraft... Reserve Policy on Payment System Risk (PSR policy) to eliminate certain posting rules to conform with... Services Analyst (202- 452-2404), Division of Reserve Bank Operations and Payment Systems. For users of...

  16. Chromatic illumination discrimination ability reveals that human colour constancy is optimised for blue daylight illuminations.

    Directory of Open Access Journals (Sweden)

    Bradley Pearce

    Full Text Available The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K, all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.

  17. Daylighting simulation : comparison of softwares for architect's utilization

    Energy Technology Data Exchange (ETDEWEB)

    Christakou, D.E.; Amorim, C.N.D. [Brazil Univ., Brasilia (Brazil). Faculty of Architecture and Urbanism

    2005-07-01

    This study analyzed and compared 4 daylighting software packages to determine the primary benefits and limits of each one, while considering the priorities for the use of the software by architects. The complex task of daylight simulation is an important step in designing buildings, particularly when the main objective is comfort and energy conservation. Simulation is not yet commonly practiced by professional architects because of the complexities of various software packages, the lack of user friendly interfaces and difficulty in interpreting results. The 4 software packages that were evaluated in this study were: (1) Desktop Radiance, (2) Rayfront, (3) Relux 2004 Vision, and (4) Lightscape. Criteria such as interfaces, flexibility, and help manuals were also analyzed in an effort to establish a frame of the main points to be considered when choosing daylighting software for architectural use, both in educational and office environments. Simulations of a test room were performed in which some parameters were modified to verify the performance of the following main criteria: flexibility in adapting to the architect's workflow; the use of state of the art algorithms; numerical precision; and, access possibility by Brazilian architects. The results demonstrate the potential of software's improvement, particular in terms of user interfaces and help manuals. The study showed that Relux 2004 Vision is the most adequate for architect's use. Rayfront and Desktop Radiance presented more difficulties in the design process, but Desktop Radiance had the advantage of being enclosed in AUTOCAD, a well known interface. Lightscape had a user friendly interface but was not as intuitive as Relux. It was concluded that the ideal daylighting simulation software does not yet exist. The ideal software should integrate diverse factors and combine edition and modeling tools beyond luminous evaluation and thermal consequences of daylight use. 5 refs., 3 tabs., 4 figs.

  18. Alumina physically loaded by thiosemicarbazide for selective preconcentration of mercury(II) ion from natural water samples

    International Nuclear Information System (INIS)

    Ahmed, Salwa A.

    2008-01-01

    The multifunctional ligand, thiosemicarbazide, was physically loaded on neutral alumina. The produced alumina-modified solid phase (SP) extractor named, alumina-modified thiosemicarbazide (AM-TSC), experienced high thermal and medium stability. This new phase was identified based on surface coverage determination by thermal desorption method to be 0.437 ± 0.1 mmol g -1 . The selectivity of AM-TSC phase towards the uptake of different nine metal ions was checked using simple, fast and direct batch equilibration technique. AM-TSC was found to have the highest capacity in selective extraction of Hg(II) from aqueous solutions all over the range of pH used (1.0-7.0), compared to the other eight tested metal ions. So, Hg(II) uptake was 1.82 mmol g -1 (distribution coefficient log K d = 5.658) at pH 1.0 or 2.0 and 1.78, 1.73, 1.48, 1.28 and 1.28 mmol g -1 (log K d = 4.607, 4.265, 3.634, 3.372 and 3.372), at pH 3.0, 4.0, 5.0, 6.0 and 7.0, respectively. On the other hand, the metal ions Ca(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II) showed low uptake values in range 0.009-0.720 mmol g -1 (log K d < 3.0) at their optimum pH values. A mechanism was suggested to explain the unique uptake of Hg(II) ions based on their binding as neutral and chloroanionic species predominate at pH values ≤3.0 of a medium rich in chloride ions. Application of the new phase for the preconcentration of ultratrace amounts of Hg(II) ions spiked natural water samples: doubly distilled water (DDW), drinking tap water (DTW) and Nile river water (NRW) using cold vapor atomic absorption spectroscopy (CV-AAS) was studied. The high recovery values obtained using AM-TSC (98.5 ± 0.5, 98.0 ± 0.5 and 103.0 ± 1.0) for DDW, DTW and NRW samples, respectively based on excellent enrichment factor 1000, along with a good precision (R.S.D.% 0.51-0.97%, n 3) demonstrate the accuracy and validity of the new modified alumina sorbent for preconcentrating ultratrace amounts of Hg(II) with no

  19. Combined daylight and intelligent LED lighting - getting the daylight into the buildings; Kombineret dagslys og intelligent LED belysning - fae dagslys ind i bygningerne. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Dam-Hansen, C.; Corell, D.D.; Thorseth, A.; Behrensdorff Poulsen, P. [Technical Univ. of Denmark, DTU Fotonik, DTU Risoe Campus, Roskilde (Denmark); Markvart, J.; Iversen, A.; Logadottir, A. [Aalborg Univ., Statens Byggeforskningsinstitut (SBi), Koebenhavn (Denmark)

    2013-03-15

    The main result of the project is the construction of the new intelligent and dynamic LED lighting system for demonstration and research purposes, and a number of extensive user testing is completed. The LED lighting system is a total system for office lighting with ceiling fixtures and desk lamps, which has made it possible to create a general and workplace lighting in two offices each with two work places. The system is installed in a day light laboratory for such two office spaces. All lamps can be controlled via a developed computer interface, and the desk lamps are further manually controllable by a user via two buttons for color temperature and brightness, respectively. The new intelligent and dynamic lighting system is based on color mixing LED technology and makes it possible to control the color composition, color coordinates and thus the color temperature of the light. Control-wise, the system is pre-programmed to produce white light with a correlated color temperature from 2700 K to 7000 K. The color composition is optimized from the desire for a very good color given at a general CRI value of 92-97 over the area. The system can be dimmed 20-100 %, with no significant change in the light's color properties. A mini-spectrometer is calibrated and built-in in the system and provides the current estimate of daylight brightness and color temperature through measurement of daylight color scheme in the visible range. The system uses daylight properties to control the light from the LED lighting system. The results of user tests show, that the developed possibility to automatically control of light in the office depending on the daylight color temperature is considered to be equally preferred and results in equally satisfied users as a traditional lighting system with even lighting in the room. On the other hand, user results showed that there were both energy savings and more satisfied users to be gained by providing users the opportunity to self-adjust either

  20. Variability of bed mobility in natural, gravel-bed channels and adjustments to sediment load at local and reach scales

    Science.gov (United States)

    Thomas E. Lisle; Jonathan M. Nelson; John Pitlick; Mary Ann Madej; Brent L. Barkett

    2000-01-01

    Abstract - Local variations in boundary shear stress acting on bed-surface particles control patterns of bed load transport and channel evolution during varying stream discharges. At the reach scale a channel adjusts to imposed water and sediment supply through mutual interactions among channel form, local grain size, and local flow dynamics that govern bed mobility...

  1. Effects of daylight-saving time changes on stock market volatility: a comment.

    Science.gov (United States)

    Kamstra, Mark J; Kramer, Lisa A; Levi, Maurice D

    2010-12-01

    In a recent article in this journal, Berument, Dogan, and Onar (2010) challenged the existence of the previously documented daylight-saving effect. Kamstra, Kramer, and Levi's original finding (2000) was that average stock market returns on Mondays following time changes are economically and statistically significantly lower than typical Monday returns. Kamstra, et al. hypothesized that the effect may arise due to heightened anxiety or risk aversion on the part of market participants after they experience a 1-hr. disruption in their sleep habits, in accordance with prior findings in the psychology literature linking sleep desynchronosis with anxiety. Berument, et al. replicated the original findings using ordinary least squares estimation, but when they modeled the mean of returns using a method prone to producing biased estimates, they obtained puzzling results. The analysis here, based on standard, unbiased modeling techniques, shows that the daylight-saving effect remains intact in the U.S.

  2. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    DEFF Research Database (Denmark)

    Freiesleben, Trine Holm; Sohbati, Reza; Murray, Andrew

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure...... and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescenceedepth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated...... events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible...

  3. Computer Modeling of Daylight-Integrated Photocontrol of Electric Lighting Systems

    Directory of Open Access Journals (Sweden)

    Richard Mistrick

    2015-05-01

    Full Text Available This article presents a variety of different approaches to both model and assess the performance of daylight-integrated electric lighting control systems. In these systems, the output of a controlled lighting zone is based on a light sensor reading and a calibrated control algorithm. Computer simulations can consider the simulated illuminance data generated from both the electric lighting system and a daylight delivery system whose performance is addressed using typical meteorological year (TMY weather data. Photosensor signals and the operation of a control system’s dimming algorithms are also included. Methods and metrics for evaluating simulated performance for the purpose of making informed design decisions that lead to the best possible installed system performance are presented.

  4. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.; Sabry, Hanan M.; Gadelhak, Mahmoud I.

    2012-01-01

    usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space

  5. Technology Assessments of High Performance Envelope with Optimized Lighting, Solar Control, and Daylighting

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; Thanachareonkit, Anothai; Touzani, Samir; Dutton, Spencer; Shackelford, Jordan; Dickerhoff, Darryl; Selkowitz, Stephen

    2016-09-01

    The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.

  6. Using the Life Satisfaction Approach to Value Daylight Savings Time Transitions: Evidence from Britain and Germany

    OpenAIRE

    Daniel Kuehnle; Christoph Wunder

    2015-01-01

    Daylight savings time (DST) represents a public good with costs and benefits. We provide the first comprehensive examination of the welfare effects of the spring and autumn transitions for the UK and Germany. Using individual-level data and a regression discontinuity design, we estimate the effect of the transitions on life satisfaction. Our results show that individuals in both the UK and Germany experience deteriorations in life satisfaction in the first week after the spring transition. We...

  7. Daylight Savings Time Transitions and the Incidence Rate of Unipolar Depressive Episodes.

    Science.gov (United States)

    Hansen, Bertel T; Sønderskov, Kim M; Hageman, Ida; Dinesen, Peter T; Østergaard, Søren D

    2017-05-01

    Daylight savings time transitions affect approximately 1.6 billion people worldwide. Prior studies have documented associations between daylight savings time transitions and adverse health outcomes, but it remains unknown whether they also cause an increase in the incidence rate of depressive episodes. This seems likely because daylight savings time transitions affect circadian rhythms, which are implicated in the etiology of depressive disorder. Therefore, we investigated the effects of daylight savings time transitions on the incidence rate of unipolar depressive episodes. Using time series intervention analysis of nationwide data from the Danish Psychiatric Central Research Register from 1995 to 2012, we compared the observed trend in the incidence rate of hospital contacts for unipolar depressive episodes after the transitions to and from summer time to the predicted trend in the incidence rate. The analyses were based on 185,419 hospital contacts for unipolar depression and showed that the transition from summer time to standard time were associated with an 11% increase (95% CI = 7%, 15%) in the incidence rate of unipolar depressive episodes that dissipated over approximately 10 weeks. The transition from standard time to summer time was not associated with a parallel change in the incidence rate of unipolar depressive episodes. This study shows that the transition from summer time to standard time was associated with an increase in the incidence rate of unipolar depressive episodes. Distress associated with the sudden advancement of sunset, marking the coming of a long period of short days, may explain this finding. See video abstract at, http://links.lww.com/EDE/B179.

  8. Apolux : an innovative computer code for daylight design and analysis in architecture and urbanism

    Energy Technology Data Exchange (ETDEWEB)

    Claro, A.; Pereira, F.O.R.; Ledo, R.Z. [Santa Catarina Federal Univ., Florianopolis, SC (Brazil)

    2005-07-01

    The main capabilities of a new computer program for calculating and analyzing daylighting in architectural space were discussed. Apolux 1.0 was designed to use three-dimensional files generated in graphic editors in the data exchange file (DXF) format and was developed to integrate an architect's design characteristics. An example of its use in a design context development was presented. The program offers fast and flexible manipulation of video card models in different visualization conditions. The algorithm for working with the physics of light is based on the radiosity method representing the surfaces through finite elements divided in small triangular units of area which are fully confronted to each other. The form factors of each triangle are determined in relation to all others in the primary calculation. Visible directions of the sky are also included according to the modular units of a subdivided globe. Following these primary calculations, the different and successive daylighting solutions can be determined under different sky conditions. The program can also change the properties of the materials to quickly recalculate the solutions. The program has been applied in an office building in Florianopolis, Brazil. The four stages of design include initial discussion with the architects about the conceptual possibilities; development of a comparative study based on 2 architectural designs with different conceptual elements regarding daylighting exploitation in order to compare internal daylighting levels and distribution of the 2 options exposed to the same external conditions; study the solar shading devices for specific facades; and, simulations to test the performance of different designs. The program has proven to be very flexible with reliable results. It has the possibility of incorporating situations of the real sky through the input of the Spherical model of real sky luminance values. 3 refs., 14 figs.

  9. Experimental primers containing synthetic and natural compounds reduce enzymatic activity at the dentin–adhesive interface under cyclic loading

    Science.gov (United States)

    Sousa, Ana Beatriz Silva; de Mattos Pimenta Vidal, Cristina; Leme-Kraus, Ariene Arcas; de Carvalho Panzeri Pires-de-Souza, Fernanda; Bedran-Russo, Ana K.

    2016-01-01

    Objective To evaluate the effect of experimental primers (chlorhexidine, enriched mixture of proanthocyanidins and doxycycline) on the adhesive properties and gelatinolytic activity at dentin-resin interfaces of occlusal Class I restorations. Methods The inactivation of enzymes by the experimental primers was assessed by fluorescence assay and gelatin zymography. To assess the adhesive properties, occlusal Class I cavities were prepared in sound human molars, etched with phosphoric acid and restored with one of the primers and an etch-and-rinse adhesive system (Adper Single Bond Plus - 3M ESPE). After the restorative procedures, the specimens were divided into two subgroups (n = 6) consisting of storage in incubation buffer or axial cyclic loading at 50 N and 1,000,000 cycles. Then, the sectioned and sliced specimens were assigned to in situ zymography assay and microtensile bond strength (TBS) test. Results Fluorescence assay and gelatin zymography revealed that the experimental primers inactivated rMMPs. In situ zymography (2-way ANOVA, Tukey, p 0.05). Significance The use of experimental primers impaired the enzymatic activity at the dentin-adhesive interface after cyclic loading and the activity of rMMPs. Cyclic loading did not have a significant effect on the bond strength. PMID:27524231

  10. Effects of daylight-saving time changes on stock market returns and stock market volatility: rebuttal.

    Science.gov (United States)

    Kamstra, Mark J; Kramer, Lisa A; Levi, Maurice D

    2013-02-01

    In a 2011 reply to our 2010 comment in this journal, Berument and Dogen maintained their challenge to the existence of the negative daylight-saving effect in stock returns reported by Kamstra, Kramer, and Levi in 2000. Unfortunately, in their reply, Berument and Dogen ignored all of the points raised in the comment, failing even to cite the Kamstra, et al. comment. Berument and Dogen continued to use inappropriate estimation techniques, over-parameterized models, and low-power tests and perhaps most surprisingly even failed to replicate results they themselves reported in their previous paper, written by Berument, Dogen, and Onar in 2010. The findings reported by Berument and Dogen, as well as by Berument, Dogen, and Onar, are neither well-supported nor well-reasoned. We maintain our original objections to their analysis, highlight new serious empirical and theoretical problems, and emphasize that there remains statistically significant evidence of an economically large negative daylight-saving effect in U.S. stock returns. The issues raised in this rebuttal extend beyond the daylight-saving effect itself, touching on methodological points that arise more generally when deciding how to model financial returns data.

  11. Daylight Design of Office Buildings: Optimisation of External Solar Shadings by Using Combined Simulation Methods

    Directory of Open Access Journals (Sweden)

    Javier González

    2015-05-01

    Full Text Available Integrating daylight and energy performance with optimization into the design process has always been a challenge for designers. Most of the building environmental performance simulation tools require a considerable amount of time and iterations for achieving accurate results. Moreover the combination of daylight and energy performances has always been an issue, as different software packages are needed to perform detailed calculations. A simplified method to overcome both issues using recent advances in software integration is explored here. As a case study; the optimization of external shadings in a typical office space in Australia is presented. Results are compared against common solutions adopted as industry standard practices. Visual comfort and energy efficiency are analysed in an integrated approach. The DIVA (Design, Iterate, Validate and Adapt plug-in for Rhinoceros/Grasshopper software is used as the main tool, given its ability to effectively calculate daylight metrics (using the Radiance/Daysim engine and energy consumption (using the EnergyPlus engine. The optimization process is carried out parametrically controlling the shadings’ geometries. Genetic Algorithms (GA embedded in the evolutionary solver Galapagos are adopted in order to achieve close to optimum results by controlling iteration parameters. The optimized result, in comparison with conventional design techniques, reveals significant enhancement of comfort levels and energy efficiency. Benefits and drawbacks of the proposed strategy are then discussed.

  12. Transition into daylight saving time influences the fragmentation of the rest-activity cycle

    Directory of Open Access Journals (Sweden)

    Tuulio-Henriksson Annamari

    2006-01-01

    Full Text Available Abstract Background Daylight saving time is widely adopted. Little is known about its influence on the daily rest-activity cycles. We decided to explore the effects of transition into daylight saving time on the circadian rhythm of activity. Methods We monitored the rest-activity cycles with the use of wrist-worn accelerometer on a sample of ten healthy adults for ten days around the transition into summer time. Identical protocols were carried out on the same individuals in two consecutive years, yielding data on 200 person-days for analysis in this study. Results There was no significant effect on the rest-activity cycle in the sample as a whole. Fragmentation of the rest-activity cycle was enhanced in a subgroup of persons having sleep for eight hours or less (P = 0.04 but reduced in those who preferred to sleep for more than eight hours per night (P = 0.05. The average level of motor activity was increased in persons having the morning preference for daily activity patterns (P = 0.01. Conclusion Transition into daylight saving time may have a disruptive effect on the rest-activity cycle in those healthy adults who are short-sleepers or more of the evening type.

  13. The shift to and from daylight savings time and motor vehicle crashes.

    Science.gov (United States)

    Lambe, M; Cummings, P

    2000-07-01

    The objective of the study was to examine whether the shifts to and from daylight savings time in Sweden have short-term effects on the incidence of traffic crashes. A database maintained by the Swedish National Road Administration was used to examine crashes from 1984 through 1995, that occurred on state roads the Monday preceding, the Monday immediately after (index Monday), and the Monday 1 week after the change to daylight savings time in the spring and for the corresponding three Mondays in the autumn. The Mondays 1 week before and after the time changes were taken as representing the expected incidence of crashes. Crash incidence was calculated per 1000 person-years using population estimates for each year of the study. The association between 1 h of possible sleep loss and crash incidence was estimated by the incidence rate ratio from negative binomial regression. The incidence rate ratio was 1.04 (95% CI, 0.92-1.16) for a Monday on which drivers were expected to have had 1 h less sleep, compared with other Mondays. In the spring, the incidence rate ratio for crashes was 1.11 (95% CI, 0.93-1.31) for Mondays after the time change compared to other spring Mondays. The corresponding rate ratio for the fall was 0.98 (95% CI, 0.84-1.15) It was concluded that the shift to and from daylight savings time did not have measurable important immediate effects on crash incidence in Sweden.

  14. Color tuning in alert macaque V1 assessed with fMRI and single-unit recording shows a bias toward daylight colors.

    Science.gov (United States)

    Lafer-Sousa, Rosa; Liu, Yang O; Lafer-Sousa, Luis; Wiest, Michael C; Conway, Bevil R

    2012-05-01

    Colors defined by the two intermediate directions in color space, "orange-cyan" and "lime-magenta," elicit the same spatiotemporal average response from the two cardinal chromatic channels in the lateral geniculate nucleus (LGN). While we found LGN functional magnetic resonance imaging (fMRI) responses to these pairs of colors were statistically indistinguishable, primary visual cortex (V1) fMRI responses were stronger to orange-cyan. Moreover, linear combinations of single-cell responses to cone-isolating stimuli of V1 cone-opponent cells also yielded stronger predicted responses to orange-cyan over lime-magenta, suggesting these neurons underlie the fMRI result. These observations are consistent with the hypothesis that V1 recombines LGN signals into "higher-order" mechanisms tuned to noncardinal color directions. In light of work showing that natural images and daylight samples are biased toward orange-cyan, our findings further suggest that V1 is adapted to daylight. V1, especially double-opponent cells, may function to extract spatial information from color boundaries correlated with scene-structure cues, such as shadows lit by ambient blue sky juxtaposed with surfaces reflecting sunshine. © 2012 Optical Society of America

  15. The role of fenestration in promoting daylight performance. The mosques of Alexandria since the 19th century

    Directory of Open Access Journals (Sweden)

    Ingy I. El-Darwish

    2016-12-01

    Full Text Available Mosques have always been sacred places with distinctive sustainable environments. Fenestration in the prayers’ zone whether clerestories, screened windows, dome lighting and other light features have managed to produce significant spiritual human comfort areas. This paper focuses on fenestration of divine mosques and relates them to promoting daylight performance. The research process emphasizes the importance of daylight performance by promoting simulation tools on historical mosques of Alexandria since the 19th century that has witnessed change over time. The paper is a step toward sustainable lighting schemes in prayers’ zones that help to achieve human comfort as well as minimize use of energy. This study aimed at investigating the daylight performance by the use of climate based daylighting metrics which is “Daylight Autonomy” (DA. Daylight Autonomy is evaluated in the year round for the day lighted prayer periods to evaluate the behavior of fenestration of the different selected sample of mosques since the 19th century in Alexandria on a simulation tool in order to check whether it complies with the required illuminate and glare levels. The research findings are an attempt to lead to performative design guidelines introducing a contemporary interpretation for use in enhancing new designs of these holistic buildings.

  16. Diluted Operation of a Heavy-Duty Natural Gas Engine - Aiming at Improved Effciency, Emission and Maximum Load

    OpenAIRE

    Kaiadi, Mehrzad

    2011-01-01

    Most heavy-duty engines are diesel operated. Severe emission regulations, high fuel prices, high technology costs (e.g. catalysts, fuel injection systems) and unsustainably in supplying fuel are enough reasons to convenience engine developers to explore alternative technologies or fuels. Using natural gas/biogas can be a very good alternative due to the attractive fuel properties regarding emission reduction and engine operation. Heavy-duty diesel engines can be easily converted for natur...

  17. Influence of Injector Location on Part-Load Performance Characteristics of Natural Gas Direct-Injection in a Spark Ignition Engine

    Energy Technology Data Exchange (ETDEWEB)

    Sevik, James [Argonne National Lab. (ANL), Argonne, IL (United States); Pamminger, Michael [Argonne National Lab. (ANL), Argonne, IL (United States); Wallner, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Scarcelli, Riccardo [Argonne National Lab. (ANL), Argonne, IL (United States); Boyer, Brad [Ford Motor Co., Detroit, MI (United States); Wooldridge, Steven [Ford Motor Co., Detroit, MI (United States); Hall, Carrie [Illinois Inst. of Technology, Chicago, IL (United States); Miers, Scott [Michigan Technological Univ., Houghton, MI (United States)

    2016-04-05

    Interest in natural gas as an alternative fuel source to petroleum fuels for light-duty vehicle applications has increased due to its domestic availability and stable price compared to gasoline. With its higher hydrogen-to-carbon ratio, natural gas has the potential to reduce engine out carbon dioxide emissions, which has shown to be a strong greenhouse gas contributor. For part-load conditions, the lower flame speeds of natural gas can lead to an increased duration in the inflammation process with traditional port-injection. Direct-injection of natural gas can increase in-cylinder turbulence and has the potential to reduce problems typically associated with port-injection of natural gas, such as lower flame speeds and poor dilution tolerance. A study was designed and executed to investigate the effects of direct-injection of natural gas at part-load conditions. Steady-state tests were performed on a single-cylinder research engine representative of current gasoline direct-injection engines. Tests were performed with direct-injection in the central and side location. The start of injection was varied under stoichiometric conditions in order to study the effects on the mixture formation process. In addition, exhaust gas recirculation was introduced at select conditions in order to investigate the dilution tolerance. Relevant combustion metrics were then analyzed for each scenario. Experimental results suggest that regardless of the injector location, varying the start of injection has a strong impact on the mixture formation process. Delaying the start of injection from 300 to 120°CA BTDC can reduce the early flame development process by nearly 15°CA. While injecting into the cylinder after the intake valves have closed has shown to produce the fastest combustion process, this does not necessarily lead to the highest efficiency, due to increases in pumping and wall heat losses. When comparing the two injection configurations, the side location shows the best

  18. Modeling illumination performance of plastic optical fiber passive daylighting system

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, F; Ahmad, A [Universiti Teknologi MARA, Shah Alam (Malaysia). Faculty of Electrical Engineering; Ahmed, A Z [Universiti Teknologi MARA, Shah Alam (Malaysia). Bureau of Reseaarch and Consultancy

    2006-12-15

    of the most direct methods of utilizing solar energy for energy conservation is to bring natural light indoors to light up an area. This paper reports on the investigation of the feasibility to utilize large core optical fibers to convey and distribute solar light passively throughout residential or commercial structures. The focus of this study is on the mathematical modeling of the illumination performance and the light transmission efficiency of solid core end light fiber for optical day lighting systems. The Meatball simulations features the optical fiber transmittance for glass and plastic fibers, illumination performance over lengths of plastic end-lit fiber, spectral transmission, light intensity loss through the large diameter solid core optical fibers as well as the transmission efficiency of the optical fiber itself. It was found that plastic optical fiber has less transmission loss over the distance of the fiber run which clearly shows that the Plastic Optical Fiber should be optimized for emitting visible light. The findings from the analysis on the performance of large diameter optical fibers for day lighting systems seems feasible for energy efficient lighting system in commercial or residential buildings.

  19. Modeling illumination performance of plastic optical fiber passive daylighting system

    International Nuclear Information System (INIS)

    Sulaiman, F.; Ahmad, A.; Ahmed, A.Z.

    2006-01-01

    One of the most direct methods of utilizing solar energy for energy conservation is to bring natural light indoors to light up an area. This paper reports on the investigation of the feasibility to utilize large core optical fibers to convey and distribute solar light passively throughout residential or commercial structures. The focus of this study is on the mathematical modeling of the illumination performance and the light transmission efficiency of solid core end light fiber for optical day lighting systems. The Meatball simulations features the optical fiber transmittance for glass and plastic fibers, illumination performance over lengths of plastic end-lit fiber, spectral transmission, light intensity loss through the large diameter solid core optical fibers as well as the transmission efficiency of the optical fiber itself. It was found that plastic optical fiber has less transmission loss over the distance of the fiber run which clearly shows that the Plastic Optical Fiber should be optimized for emitting visible light. The findings from the analysis on the performance of large diameter optical fibers for day lighting systems seems feasible for energy efficient lighting system in commercial or residential buildings

  20. Enhancing load-following and/or spectral shift capability in single-sparger natural circulation boiling water reactors

    International Nuclear Information System (INIS)

    Oosterkamp, W.J.

    1992-01-01

    This patent describes a method for obtaining load-following capability in a coiling water reactor (BWR) wherein housed within a reactor pressure vessel (RPV) is a nuclear core disposed within a shroud having a shroud head and which with the RPV defines an annulus region disposed beneath the nuclear core, an upper steam dome connected to a steam outlet in the RPV, a core upper plenum formed within the shroud head and disposed atop the nuclear core, a chimney mounted atop the shroud head and in fluid communication with the core upper plenum and with a steam separator having a skirt which is in fluid communication with the steam dome, the region outside of the chimney defining a downcomer region, there being a water level established therein under normal operation of the BWR, and the RPV containing a feedwater inlet. It comprises: disposing a single sparger connected to the feedwater inlet above the steam separator skirt bottom about the interior circumference of the RPV at an elevation at approximately the water level established during normal operation of the BWR; and adjusting the feedwater flow through the inlet and into the sparger to vary the water level to be above, at or below the elevational location of the sparger in response to load-following need

  1. Daylight photocatalysis performance of biomorphic CeO2 hollow fibers prepared with lens cleaning paper as biotemplate

    International Nuclear Information System (INIS)

    Qian, Junchao; Chen, Feng; Wang, Fang; Zhao, Xiaobing; Chen, Zhigang

    2012-01-01

    Highlights: ► A novel, simple and eco-friendly approach for hierarchical, biomorphic CeO 2 hollow fibers with mesoporous tube walls is presented by using paper as template. ► The biomorphic CeO 2 fibers was composed of nanosheets with bimodal pore-size mesoporous distribution and exhibited high light-harvesting under sunlight irradiation. ► The CeO 2 microfibers biomimicking the natural plant structures have promising application for photodegradation of organic pollutants in water. -- Abstract: Hierarchical, biomorphic CeO 2 hollow fibers with mesoporous tube walls have been fabricated using lens cleaning paper as biotemplates. After sintered at 550 °C in air, the cellulosic fibers of paper were converted into micro-tubes composing of CeO 2 crystallites with grain size about 8 nm. The photocatalytic activity of the CeO 2 fibers was evaluated by photodegradation efficiency of methylene blue in aqueous solution under daylight irradiation. The characterized results show that the CeO 2 fibers faithfully replicated micro-fibrous structure derived from original template and possessed dramatic enhanced photocatalytic activity compared with bulk CeO 2 . This simple biotemplate method provides a cost-effective and eco-friendly route to obtain high performance photocatalysts.

  2. Daylight photocatalysis performance of biomorphic CeO{sub 2} hollow fibers prepared with lens cleaning paper as biotemplate

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Junchao; Chen, Feng [Department of Material Science and Engineering, Jiangsu University, 212013 Zhenjiang (China); Wang, Fang; Zhao, Xiaobing [Department of Materials Science and Engineering, Changzhou University, 213164 Changzhou (China); Chen, Zhigang, E-mail: ziyou1900@gmail.com [Department of Material Science and Engineering, Jiangsu University, 212013 Zhenjiang (China); Jiangsu Key Laboratory for Environment Functional Materials, 215009 Suzhou University of Science and Technology, Suzhou (China); State Key laboratory of Crystal Material, Shandong University, 250100 Jinan (China)

    2012-08-15

    Highlights: ► A novel, simple and eco-friendly approach for hierarchical, biomorphic CeO{sub 2} hollow fibers with mesoporous tube walls is presented by using paper as template. ► The biomorphic CeO{sub 2} fibers was composed of nanosheets with bimodal pore-size mesoporous distribution and exhibited high light-harvesting under sunlight irradiation. ► The CeO{sub 2} microfibers biomimicking the natural plant structures have promising application for photodegradation of organic pollutants in water. -- Abstract: Hierarchical, biomorphic CeO{sub 2} hollow fibers with mesoporous tube walls have been fabricated using lens cleaning paper as biotemplates. After sintered at 550 °C in air, the cellulosic fibers of paper were converted into micro-tubes composing of CeO{sub 2} crystallites with grain size about 8 nm. The photocatalytic activity of the CeO{sub 2} fibers was evaluated by photodegradation efficiency of methylene blue in aqueous solution under daylight irradiation. The characterized results show that the CeO{sub 2} fibers faithfully replicated micro-fibrous structure derived from original template and possessed dramatic enhanced photocatalytic activity compared with bulk CeO{sub 2}. This simple biotemplate method provides a cost-effective and eco-friendly route to obtain high performance photocatalysts.

  3. Modulation of drug release from nanocarriers loaded with a poorly water soluble drug (flurbiprofen) comprising natural waxes.

    Science.gov (United States)

    Baviskar, D T; Amritkar, A S; Chaudhari, H S; Jain, D K

    2012-08-01

    In this study, flurbiprofen (FLB) Solid Lipid Nanoparticles (SLN) composed from a mixture of beeswax and carnauba wax, Tween 80 and egg lecithin as emulsifiers have been prepared. FLB was incorporated as model lipophilic drug to assess the influence of matrix composition in the drug release profile. SLN were produced by microemulsion technique. In vitro studies were performed in Phosphate Buffered Saline (PBS). The FLB loaded SLN showed a mean particle size of 75 +/- 4 nm, a polydispersity index approximately 0.2 +/- 0.02 and an entrapment efficiency (EE) of more than 95%. Suspensions were stable, with zeta potential values in the range of -15 to -17 mV. DSC thermograms and UV analysis indicated the stability of nanoparticles with negligible drug leakage. Nanoparticles with higher beeswax content in their core exhibited faster drug release than those containing more carnauba wax.

  4. Statistically-Based Comparison of the Removal Efficiencies and Resilience Capacities between Conventional and Natural Wastewater Treatment Systems: A Peak Load Scenario

    Directory of Open Access Journals (Sweden)

    Long Ho

    2018-03-01

    Full Text Available Emerging global threats, such as climate change, urbanization and water depletion, are driving forces for finding a feasible substitute for low cost-effective conventional activated sludge (AS technology. On the other hand, given their low cost and easy operation, nature-based systems such as constructed wetlands (CWs and waste stabilization ponds (WSPs appear to be viable options. To examine these systems, a 210-day experiment with 31 days of peak load scenario was performed. Particularly, we conducted a deliberate strategy of experimentation, which includes applying a preliminary study, preliminary models, hypothetical tests and power analysis to compare their removal efficiencies and resilience capacities. In contrast to comparable high removal efficiencies of organic matter—around 90%—both natural systems showed moderate nutrient removal efficiencies, which inferred the necessity for further treatment to ensure their compliance with environmental standards. During the peak period, the pond treatment systems appeared to be the most robust as they indicated a higher strength to withstanding the organic matter and nitrogen shock load and were able to recover within a short period. However, high demand of land—2.5 times larger than that of AS—is a major concern of the applicability of WSPs despite their lower operation and maintenance (O&M costs. It is also worth noting that initial efforts on systematic experimentation appeared to have an essential impact on ensuring statistically and practically meaningful results in this comparison study.

  5. natural

    Directory of Open Access Journals (Sweden)

    Elías Gómez Macías

    2006-01-01

    Full Text Available Partiendo de óxido de magnesio comercial se preparó una suspensión acuosa, la cual se secó y calcinó para conferirle estabilidad térmica. El material, tanto fresco como usado, se caracterizó mediante DRX, área superficial BET y SEM-EPMA. El catalizador mostró una matriz de MgO tipo periclasa con CaO en la superficie. Las pruebas de actividad catalítica se efectuaron en lecho fijo empacado con partículas obtenidas mediante prensado, trituración y clasificación del material. El flujo de reactivos consistió en mezclas gas natural-aire por debajo del límite inferior de inflamabilidad. Para diferentes flujos y temperaturas de entrada de la mezcla reactiva, se midieron las concentraciones de CH4, CO2 y CO en los gases de combustión con un analizador de gases tipo infrarrojo no dispersivo (NDIR. Para alcanzar conversión total de metano se requirió aumentar la temperatura de entrada al lecho a medida que se incrementó el flujo de gases reaccionantes. Los resultados obtenidos permiten desarrollar un sistema de combustión catalítica de bajo costo con un material térmicamente estable, que promueva la alta eficiencia en la combustión de gas natural y elimine los problemas de estabilidad, seguridad y de impacto ambiental negativo inherentes a los procesos de combustión térmica convencional.

  6. Corrosion characteristics of a 4-year naturally corroded reinforced concrete beam with load-induced transverse cracks

    International Nuclear Information System (INIS)

    Fu, Chuanqing; Jin, Nanguo; Ye, Hailong; Jin, Xianyu; Dai, Wei

    2017-01-01

    Highlights: • A comprehensive study of corrosion characteristics of a naturally corroded RC beam. • New insights on the role of cracks in corrosion propagation of steel in concrete. • EMPA and 3D laser scanning provide quantitative analysis of corroded rebar. - Abstract: This work studies the corrosion characteristics of reinforcement in a 4-year naturally corroded concrete beam after accelerated chloride penetration. The results show that the presence of transverse cracks in the tension surface of reinforced concrete beam can globally exacerbate the loss of cross-sectional area of rebar. However, there is no strong correlation between the width of transverse cracks, with the width of longitudinal cracks and loss of cross-sectional area of corroded rebar at a specific location. The self-healing of cracks and sacrificing roles of stirrups at crack tips seem to reduce the impacts of cracks on the corrosion propagation.

  7. Development and in vitro evaluation of diclofenac sodium loaded mucoadhesive microsphere with natural gum for sustained delivery.

    Science.gov (United States)

    Amin, Md Lutful; Jesmeen, Tasbira; Sutradhar, Kumar Bishwajit; Mannan, Md Abdul

    2013-12-01

    The objective of this study was to develop and evaluate mucoadhesive microsphere of diclofenac sodium with natural gums for sustained delivery. Guar gum and tragacanth were used along with sodium alginate as mucoadhesive polymers. Microspheres were formulated using orifice-ionic gelation method. Particle size, surface morphology, swelling study and drug entrapment efficiency of the prepared microspheres were determined. In vitro evaluation was carried out comprising of mucoadhesion and drug release study. The prepared microspheres were discrete and free flowing. Sodium alginate and natural gum, at a ratio of 1:0.25, showed good mucoadhesive property and they had high drug entrapment efficiencies. They also exhibited the best rate retarding effect among all the formulations. Drug entrapment efficiency of all the microspheres ranged from 80.42% to 91.67%. An inverse relationship was found between extent of crosslinking and drug release rate. Release rate was slow and extended in case of the formulations of 1:0.25 ratio (F1 and F3), releasing 68.36% and 70.56% drug respectively after 8 hours. Tragacanth-containing microspheres of F1 showed superiority over other formulations, with best mucoadhesive and rate retarding profile. The correlation value (r(2)) indicated that the drug release of all the formulations followed Higuchi's model. Overall, the results indicated that mucoadhesive microspheres containing natural gum can be promising in terms of prolonged delivery with good mucoadhesive action, targeting the absorption site to thrive oral drug delivery.

  8. Optimal sun-shading design for enhanced daylight illumination of subtropical classrooms

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Ming-Chin [Architecture and Building Research Institute, MOI (China); Chiang, Che-Ming [Department of Architecture, National Cheng-Kung University, Tainan 701 (China); Chou, Po-Cheng [Department of Interior Design, Shu-Te University, No. 59 Hun-Shan Road, Yenchau 82445, Kaohsiung County (China); Chang, Kuei-Feng [Department of Real Estate Management, National Pingtung Institute of Commerce (China); Lee, Chia-Yen [Department of Mechanical and Automation Engineering, Da-Yeh University, Changhua 515 (China)

    2008-07-01

    This study investigates the feasibility of fitting windows with sun-shadings in order to minimize the lighting power costs in daylight-illuminated classrooms lit from a single side in subtropical regions. An IES-CPC model is created of a representative classroom in Taiwan, and a series of simulations is performed to determine the average illuminance value and the uniformity of the illuminance distribution in the classroom under various lighting conditions with no sun-shadings fitted to the window. The numerical results are found to be in good agreement with the experimental measurements obtained using an array of nine-channel photometers. Having confirmed the validity of the simulation scheme, the illumination properties of four different sun-shading designs are considered. The results show that a double-layered sun-shading represents the optimal sun-shading design in terms of achieving a uniform illumination distribution within the classroom. Given appropriate physical dimensions, this daylight access device achieves the minimum illuminance requirement of 500 lx and improves the lighting uniformity ratio from 0.25-0.35 to 0.40-0.42. Furthermore, using this sun-shading device, the required illuminance ratio of 0.5 can be obtained simply by switching on one of the three rows of lights in the classroom. Accordingly, the daylight access device not only improves the illuminance conditions within the classroom, but also reduces the lighting power cost by 71.5% compared to the case where all of the lights are turned on. (author)

  9. Daylight Utilization with Light Pipe in Farm Animal Production: A Simulation Approach

    Directory of Open Access Journals (Sweden)

    Alejandro Pacheco Diéguez’

    2016-06-01

    Full Text Available Light pipes offer a passive way to bring daylight inside deep buildings, such as agricultural buildings. However, the lack of reliable performance predictability methods for light pipes represents a major obstacle preventing their widespread use. This paper evaluates a simulation approach for performance prediction and identifies key light pipe design parameters affecting their daylight transmission performance. The study was carried out through continuous monitoring of daylight in two full-scale, identical pig stables fitted with two light pipe systems, Solatube® and Velux®. The experiment included three continuously measuring sensors in each stable and an outdoor sensor during 2013 and 2014. A forward raytracing tool, TracePro®, was used for illuminance prediction and parametric simulations. The simulation results for overcast skies indicated discrepancies between the simulated and average measurement results below 30% in all cases. The discrepancies for clear skies were somewhat higher, i.e., below 30% for 67% of the cases. The higher discrepancies with clear skies were due to the overestimation of absolute sunlight levels and absence of an advanced and detailed optical characterization of the dome collector’s surface. The parametric results have shown that light pipes’ performance is better during summer time, in sunny climates, at low to mid-latitudes, which provides higher solar altitudes than during winter and cloudy climates at high latitudes. Methods to improve the luminous transmittance for low solar altitudes occurring in Scandinavia include: bending or tilting the pipe, increasing the aspect ratio, improving the pipe specular reflectance, tilting the collector to the south, and using optical redirecting system in the collector.

  10. The influence of the lateral distances between buildings on the availability of indoor daylighting

    Directory of Open Access Journals (Sweden)

    Andrea Coelho Laranja

    2014-12-01

    Full Text Available This study addresses aspects related to daylighting in the indoor environment, more specifically the influence of lateral distances between obstructing buildings on the availability of indoor daylighting, taking the height of the buildings and width of the roads into account. In accordance with the adopted methodology, comparisons were made of the percentage of illuminance values of the internal environment by using UDI (Useful Daylight Illuminance ranges on a selected point within an interior environment with an opening oriented to the North. The percentages of illuminance values were generated by simulation using the TropLux program in a rectangular geometry environment inserted in an urban setting in the city of Vitória, Espírito Santo (Latitude 20°19'S. The simulations were carried out for three types of sky patterns recognized by the CIE (Commission Internationale L'aclairage. One of the main results of this study was that, in locations with sky types 3 (overcast, 7 (partly cloudy, and 12 (clear, there were greater variations in the average annual internal illuminance when there were changes in the lateral distances between the obstructing buildings that were not directly in front of the building that was being analyzed. It was also found that in area with sky types 3 (overcast, 7 (partly cloudy, and 12 (clear, changes in the lateral distances between the three obstructing buildings had little effect on percentage changes in the 100≤UDI≤500 lux range and 500≤UDI ≤2000 lux range.

  11. Impact of solar shading on daylight quality. Measurements in experimental office rooms

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.C.

    2001-07-01

    The impact of ten solar shading screens and one venetian blind on daylight quality was studied through measurements in two south-oriented experimental office rooms. The daylight quality was assessed by considering five performance indicators: the daylight factor, the work plane illuminance, the illuminance uniformity on the work plane, the absolute luminance in the field of view and the luminance ratios between the paper task, the walls and the VDT screen. The measurements were carried out under perfect sunny conditions and overcast conditions. The results show that the shading devices can be divided into three distinct groups. Group 1 consists of all dark-coloured screens; Group 2 includes the closed venetian blind while Group 3 includes the white screens and the horizontal venetian blind. The devices of Group 1 produced unacceptably low work plane illuminance and vertical luminance values which resulted in unsuitable luminance ratios between the task, the walls and VDT screen. However, these devices reduced the luminance of the window (sky) to acceptable levels. The devices of Group 3 did not prevent high window luminance but yielded higher levels of work plane illuminance and inner wall luminance, which makes them suitable for traditional paper tasks. They also generated high wall luminance values which resulted in a number of unacceptable luminance ratios between the task, walls and VDT screen. The closed venetian blind (Group 2) was the only device which scored well on all performance indicators considered. It provided ideal illuminance levels for paper and VDT tasks and resulted in favourable wall luminance values for computer work.

  12. Critical analysis of the daylight saving time; Analisis critico al horario del verano

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes Rubio, Hernando [Universidad Autonoma Metropolitana Ciudad-Ixtapalapa, Mexico, D.F., (Mexico)

    2001-07-01

    The critical analysis is presented as a synthesis of the problem untied since the implementation of the daylight saving time. The often related history is retaken to introduce the reader into the context of the causes of a such program. The geometric aspect of the solar trajectories is discussed and the length of the day as a function of the latitude and the time of the year to have technical elements for the time displacement in a certain region. The technical implementation of the daylight saving time based on three elements is justified: time of dawn and the decline (length of the day), national economic motivation and tourism industry. Stands out that although the daylight saving time schedule has a set of social and economic benefits it is not centered in the individual but in the society as a whole. The errors in handling the information and the misinformation are pointed out as the main causes of the controversy, the discord and the political manipulation of competing groups. [Spanish] El analisis critico se presenta como una sintesis del problema desatado desde la implementacion del horario de verano. La historia muchas veces contada se retoma para introducir al lector en el contexto de las causas de un tal programa. Se discute el aspecto geometrico de las trayectorias solares y la longitud del dia como una funcion de la latitud y de la epoca del ano para tener elementos tecnicos para el desplazamiento horario en una region determinada. Se justifica la implementacion tecnica del horario de verano en funcion de tres elementos: hora de alba y del ocaso (longitud del dia), motivacion economica nacional e industria turistica. Se destaca que si bien el horario de verano tiene un conjunto de beneficios sociales y economicos no se centra en el individuo sino en la sociedad en su conjunto. Se senalan los errores de manejo de la informacion y la desinformacion como los principales causantes de la polemica, el desacuerdo y la manipulacion politica de grupos

  13. Overheating and Daylighting; Assessment Tool in Early Design of London’s High-Rise Residential Buildings

    Directory of Open Access Journals (Sweden)

    Bachir Nebia

    2017-08-01

    Full Text Available High-rise residential buildings in dense cities, such as London, are a common response to housing shortage. The apartments in these buildings may experience different levels of thermal and visual comfort, depending on their orientation and floor level. This paper aims to develop simplified tools to predict internal temperatures and daylighting levels, and propose a tool to quickly assess overheating risk and daylight performance in London’s high-rise residential buildings. Single- and double-sided apartments in a high-rise building were compared, and the impact of their floor level, glazing ratio, thermal mass, ventilation strategy and orientation was investigated. Using Integrated Environmental Solutions Virtual Environment (IES VE, temperature and daylight factor results of each design variable were used to develop early design tools to predict and assess overheating risks and daylighting levels. The results indicate that apartments that are more exposed to solar radiations, through either orientation or floor level, are more susceptible to overheat in the summer while exceeding the daylighting recommendations. Different design strategies at different levels and orientations are subsequently discussed.

  14. Analysing the impact of reflectance distributions and well geometries on vertical surface daylight levels in atria for overcast skies

    Energy Technology Data Exchange (ETDEWEB)

    Du, Jiangtao; Sharples, Steve [School of Architecture, University of Sheffield, Crookesmoor Building, Conduit Road, Sheffield S10 1FL (United Kingdom)

    2010-07-15

    This study investigated the impacts of different diffuse reflectance distributions and well geometries on vertical daylight factors and vertical internally reflected components in atria. Two forms of reflectance distribution patterns of wall surface were examined: horizontal and vertical reflectance band variation. The square atrium models studied have a broader WI range of 0.25-2.0, which represent shallow, medium and high atria. Radiance, a powerful package based on backward ray tracing technique, was used for the simulations of vertical daylight levels. The results show that different reflectance distributions of square atrium walls do have an impact on the vertical daylight factors and vertical internally reflected components under overcast sky condition. The impact relates to the orientation of the band with different reflectance distributions on the wall. Compared with the vertical band surface, the horizontal band surface has a much more complicated effect. The horizontal distributions of the reflectances significantly affects the vertical daylight levels at the locations more than 30% atrium height on the wall. For an atrium with a height more than 1/2 the width, the effect tends to increase with the increasing well index. The vertical distributions of the reflectance, nevertheless, do not substantially take effect on the vertical daylight levels in atria except for some special reflectance distribution patterns. (author)

  15. Effects of Daylight Saving Time changes on stock market volatility: a reply.

    Science.gov (United States)

    Berument, Hakan; Dogan, Nukhet

    2011-12-01

    There is a rich array of evidence that suggests that changes in sleeping patterns affect an individual's decision-making processes. A nationwide sleeping-pattern change happens twice a year when the Daylight Saving Time (DST) change occurs. Kamstra, Kramer, and Levi argued in 2000 that a DST change lowers stock market returns. This study presents evidence that DST changes affect the relationship between stock market return and volatility. Empirical evidence suggests that the positive relationship between return and volatility becomes negative on the Mondays following DST changes.

  16. Effect of short-term simulated daylight exposure on optically brightened papers

    International Nuclear Information System (INIS)

    Green, Phil; Honess, Mike

    2010-01-01

    Two optically brightened commercial papers were subjected to 72 hours continuous exposure to graphic arts daylight simulating fluorescent lamps at 1.4 and 4.4 klux. At the higher illuminance level, a CIELAB colour difference of 1.0 was reached in approximately 3 and 50 hours for the two papers. The colour differences produced by the 1.4 klux exposure were greater than that predicted by assuming a linear relationship between intensity and colour change, by a factor of 1.8.

  17. Development of a new model to predict indoor daylighting: Integration in CODYRUN software and validation

    Energy Technology Data Exchange (ETDEWEB)

    Fakra, A.H., E-mail: fakra@univ-reunion.f [Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT), University of La Reunion, 117 rue du General Ailleret, 97430 Le Tampon (French Overseas Dpt.), Reunion (France); Miranville, F.; Boyer, H.; Guichard, S. [Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT), University of La Reunion, 117 rue du General Ailleret, 97430 Le Tampon (French Overseas Dpt.), Reunion (France)

    2011-07-15

    Research highlights: {yields} This study presents a new model capable to simulate indoor daylighting. {yields} The model was introduced in research software called CODYRUN. {yields} The validation of the code was realized from a lot of tests cases. -- Abstract: Many models exist in the scientific literature for determining indoor daylighting values. They are classified in three categories: numerical, simplified and empirical models. Nevertheless, each of these categories of models are not convenient for every application. Indeed, the numerical model requires high calculation time; conditions of use of the simplified models are limited, and experimental models need not only important financial resources but also a perfect control of experimental devices (e.g. scale model), as well as climatic characteristics of the location (e.g. in situ experiment). In this article, a new model based on a combination of multiple simplified models is established. The objective is to improve this category of model. The originality of our paper relies on the coupling of several simplified models of indoor daylighting calculations. The accuracy of the simulation code, introduced into CODYRUN software to simulate correctly indoor illuminance, is then verified. Besides, the software consists of a numerical building simulation code, developed in the Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT) at the University of Reunion. Initially dedicated to the thermal, airflow and hydrous phenomena in the buildings, the software has been completed for the calculation of indoor daylighting. New models and algorithms - which rely on a semi-detailed approach - will be presented in this paper. In order to validate the accuracy of the integrated models, many test cases have been considered as analytical, inter-software comparisons and experimental comparisons. In order to prove the accuracy of the new model - which can properly simulate the illuminance - a

  18. Integrated control of sun shades, daylight and artificial light; Integreret regulering af solafskaermning, dagslys og kunstlys

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, K.; Christoffersen, J.; Soerensen, Henrik; Jessen, G.

    2011-07-01

    The project established a basis of calculation and a practical basis for optimum choice of solar shading and integrated control strategies for both new buildings and for office, commercial and institutional buildings to be renovated with new calculation models for controlling solar shading integrated in the BSim program. A complete and applicable model for optimum, integrated solar shading control was established, focusing on thermal and visual comfort criteria towards energy consumption for heating, cooling and lighting. A prototype was tested in the daylight laboratory at Danish Building Research Institute-Aalborg University and at University of Southern Denmark. (LN)

  19. Yellowing of coated papers under the action of heat, daylight radiation, and nitrogen oxide gas

    International Nuclear Information System (INIS)

    Mailly, V.; Le Nest, J.F.; Tosio, J.M.S.; Silvy, J.

    1997-01-01

    In the area of coated papers, a high degree of whiteness is often required to carry a quality image. Coated papers however are sensitive to the environment where they are stored and have tendency to yellow. The aim of this work was to study the influence of(i) daylight radiation and (ii) nitrogen oxide gas (NO2 ) on the yellowing of coated papers. In a previous study (l), we had established the presence of NO2 in the environment of some coating machines because of the transformation of ammonium hydroxide (NH4 OH, a component of some coating colors) into nitrogen oxide through the burners of hot air supplier-systems

  20. Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Gregory; Mistrick, Ph.D., Richard; Lee, Eleanor; McNeil, Andrew; Jonsson, Ph.D., Jacob

    2011-01-21

    We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.

  1. Daylight saving time can decrease the frequency of wildlife–vehicle collisions

    Science.gov (United States)

    Ellis, William A.; FitzGibbon, Sean I.; Barth, Benjamin J.; Niehaus, Amanda C.; David, Gwendolyn K.; Taylor, Brendan D.; Matsushige, Helena; Melzer, Alistair; Bercovitch, Fred B.; Carrick, Frank; Jones, Darryl N.; Dexter, Cathryn; Gillett, Amber; Predavec, Martin; Lunney, Dan

    2016-01-01

    Daylight saving time (DST) could reduce collisions with wildlife by changing the timing of commuter traffic relative to the behaviour of nocturnal animals. To test this idea, we tracked wild koalas (Phascolarctos cinereus) in southeast Queensland, where koalas have declined by 80% in the last 20 years, and compared their movements with traffic patterns along roads where they are often killed. Using a simple model, we found that DST could decrease collisions with koalas by 8% on weekdays and 11% at weekends, simply by shifting the timing of traffic relative to darkness. Wildlife conservation and road safety should become part of the debate on DST. PMID:27881767

  2. Does extending daylight saving time save energy? Evidence from an Australian experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kellogg, R. [California Univ., Berkeley, CA (United States). Dept. of Agricultural and Resource Economics; Wolff, H. [California Univ., Berkeley, CA (United States). Dept. of Agricultural and Resource Economics]|[Forschungsinstitut zur Zukunft der Arbeit (IZA), Bonn (Germany)

    2007-03-15

    Several countries are considering extending Daylight Saving Time (DST) in order to conserve energy, and the U.S. will extend DST by one month beginning in 2007. However, projections that these extensions will reduce electricity consumption rely on extrapolations and simulations rather than empirical evidence. This paper, in contrast, examines a quasiexperiment in which parts of Australia extended DST in 2000 to facilitate the Sydney Olympics. Using detailed panel data and a triple differences specification, we show that the extension did not conserve electricity, and that a prominent simulation model overstates electricity savings when it is applied to Australia. (orig.)

  3. Use of a Novel Rover-mounted Fluorescence Imager and Fluorescent Probes to Detect Biological Material in the Atacama Desert in Daylight

    Science.gov (United States)

    Weinstein, S.; Pane, D.; Warren-Rhodes, K.; Cockell, C.; Ernst, L. A.; Minkley, E.; Fisher, G.; Emani, S.; Wettergreen, D. S.; Wagner, M.

    2005-01-01

    We have developed an imaging system, the Fluorescence Imager (FI), for detecting fluorescence signals from sparse microorganisms and biofilms during autonomous rover exploration. The fluorescence signals arise both from naturally occurring chromophores, such as chlorophyll of cyanobacteria and lichens, and from fluorescent probes applied to soil and rocks. Daylight imaging has been accomplished by a novel use of a high-powered flashlamp synchronized to a CCD camera. The fluorescent probes are cell permanent stains that have extremely low intrinsic fluorescence (quantum yields less than 0.01) and a large fluorescence enhancement (quantum yields greater than 0.4) when bound to the target. Each probe specifically targets either carbohydrates, proteins, nucleic acids or membrane lipids, the four classes of macromolecules found in terrestrial life. The intent of the probes is to interrogate the environment for surface and endolithic life forms.

  4. Properties of rubber blends based on natural rubber loaded with different fillers and cured by gamma radiation

    International Nuclear Information System (INIS)

    Mohamed, R.M.

    2011-01-01

    In this investigation system styrene butadiene rubber (1502 type) and natural rubber were blended in different ratios namely, NR/SBR (0/100), NR/SBR (25/75), NR/SBR (50/50), NR/SBR (75/25) and NR/SBR (100/0). All the samples were subjected to gamma irradiation dose up to 250 kGy. The improvement in the mechanical properties, physico-mechanical properties and thermal properties was followed as a function of irradiation dose and blend ratio. The SBR /NR (50/50) blend with reasonable properties were filled with 40 p hr of Hisil (highly fined silicon), HAF carbon black (high abrasion furnace), TiO 2 titanium dioxide and clay; the reinforcing ability of these fillers was found to follow the order: Hisil > HAF carbon black > Clay > TiO 2 The effect of different kinds of enhancing agents (coagent) namely: N, N- methylene di acrylamide (MDA), trimethylol propane tri methacrylate (TMPTMA) and tetramethylol - methane tetraacrylate (TMMT) on the properties of the obtained composites as a function of irradiation dose was studied. The data obtained showed that the enhancement character of the co agents follow the order: TMMT >TMPTMA > MDA >unenhanced composites. This investigation showed also the effect of gamma irradiation on improving the above mentioned properties in the presence of filler and co agents. Moreover, radiation dose at 100 kGy is sufficient enough for obtained the desired properties. The obtaining composites can be used in many industrial applications such as radio controlled model race car tires to footwear applications; the SBR component adds the toughness while the natural rubber provides superior resilience and energy return when used in footwear.

  5. Development of new types of sun shielding systems based on daylight conducting sun shielding glass slats; Udvikling af nye typer solafskaermningssystemer baseret paa dagslysdirigerende solafskaermende glaslameller

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, A.; Svendsen, Svend (Danmarks Tekniske Univ., DTU Byg, Kgs. Lyngby (Denmark)); Laustsen, J.B. (NIRAS A/S (Denmark)); Traberg-Borup, S.; Johnsen, Kjeld (Statens Byggeforskningsinstitut, Aalborg Univ. (Denmark))

    2009-11-15

    The project has developed a new solar shading system consisting of reflective reflective glass slats, which both must act as general sun shading and also be able to improve daylight conditions inside the building when it's needed, by reflecting light further into the room. Simulations with the program IESve / Radiance are performed of daylight conditions in an office room using the developed solar shading concept. The calculation model is used to optimize the glass slat system's shape and dimensions (slat angle, width and distance). The calculations have shown that a slat angle of 30 degrees gives the best daylight conducting effect in overcast weather. At this position, compared with the same facade without sun shading, a slight reduction of daylight factor close to the windows is obtained while the back of the room is largely unchanged. Compared with traditional slat systems the reflective glass slats provide higher daylight factors in the building. Daylight measurements are performed in a daylight laboratory. Measurements show that the daylight factor in cloudy weather is reduced by approx. 20% 1.2 m from the facade where there are usually plenty of light while it is unchanged or slightly higher at the back of the room where there often are problems with too little daylight. On a clear day with direct sunlight and the reflective slats in shading position the result is a reduction of illumination through the whole room. The developed sun shading system reduces sun irradiance in reflective position without diminishing daylight conditions in the building under overcast conditions when the slats are angled in daylight conducting position. The glass slat system's effect on the thermal indoor environment and energy consumption are analyzed using calculations in the program BSim and by measurements of the sun shading system mounted in the Passys test cell at the Technical University of Denmark. (ln)

  6. Iron loading effects in Fe/SSZ-13 NH3-SCR catalysts: nature of the Fe-ions and structure-function relationships

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Feng; Zheng, Yang; Kukkadapu, Ravi K.; Wang, Yilin; Walter, Eric D.; Schwenzer, Birgit; Szanyi, Janos; Peden, Charles HF

    2016-05-06

    Using a traditional aqueous solution ion-exchange method under a protecting atmosphere of N2, a series of Fe/SSZ-13 catalysts with various Fe loadings were synthesized. UV-Vis, EPR and Mössbauer spectroscopies, coupled with temperature programmed reduction and desorption techniques, were used to probe the nature of the Fe sites. The major monomeric and dimeric Fe species are extra-framework [Fe(OH)2]+ and [HO-Fe-O-Fe-OH]2+. Larger oligomers with unknown nuclearity, poorly crystallized Fe2O3 particles, together with isolated Fe2+ ions, are minor Fe-containing moieties. Reaction rate and Fe loading correlations suggest that isolated Fe3+ ions are the active sites for standard SCR while the dimeric sites are the active centers for NO oxidation. NH3 oxidation, on the other hand, is catalyzed by sites with higher nuclearity. A low-temperature standard SCR reaction network is proposed that includes redox cycling of both monomeric and dimeric Fe species, for SCR and NO2 generation, respectively. The authors gratefully acknowledge the US Department of Energy (DOE), Energy Efficiency and Renewable Energy, Vehicle Technologies Program for the support of this work. The research described in this paper was performed at the Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory (PNNL). PNNL is operated for the US DOE by Battelle.

  7. Effects of non-fatiguing respiratory muscle loading induced by expiratory flow limitation during strenuous incremental cycle exercise on metabolic stress and circulating natural killer cells.

    Science.gov (United States)

    Rolland-Debord, Camille; Morelot-Panzini, Capucine; Similowski, Thomas; Duranti, Roberto; Laveneziana, Pierantonio

    2017-12-01

    Exercise induces release of cytokines and increase of circulating natural killers (NK) lymphocyte during strong activation of respiratory muscles. We hypothesised that non-fatiguing respiratory muscle loading during exercise causes an increase in NK cells and in metabolic stress indices. Heart rate (HR), ventilation (VE), oesophageal pressure (Pes), oxygen consumption (VO 2 ), dyspnoea and leg effort were measured in eight healthy humans (five men and three women, average age of 31 ± 4 years and body weight of 68 ± 10 kg), performing an incremental exercise testing on a cycle ergometer under control condition and expiratory flow limitation (FL) achieved by putting a Starling resistor. Blood samples were obtained at baseline, at peak of exercise and at iso-workload corresponding to that reached at the peak of FL exercise during control exercise. Diaphragmatic fatigue was evaluated by measuring the tension time index of the diaphragm. Respiratory muscle overloading caused an earlier interruption of exercise. Diaphragmatic fatigue did not occur in the two conditions. At peak of flow-limited exercise compared to iso-workload, HR, peak inspiratory and expiratory Pes, NK cells and norepinephrine were significantly higher. The number of NK cells was significantly related to ΔPes (i.e. difference between the most and the less negative Pes) and plasmatic catecholamines. Loading of respiratory muscles is able to cause an increase of NK cells provided that activation of respiratory muscles is intense enough to induce a significant metabolic stress.

  8. The Ability of Tourist Natural Trails to Resist Tourism Load and Possibilities for Reducing the Environmental Impacts : Case Study of the Slovak Paradise National Park (Slovakia

    Directory of Open Access Journals (Sweden)

    Janočková Jana

    2015-09-01

    Full Text Available The strictly protected natural area of Sucha Bela Gorge, located in the Slovak Paradise National Park, Slovakia, is exposed to environmental degradation by heavy tourist loads. Although educational and technical measures have been put in place, there is ongoing debate whether and how to limit the intensity of tourist visits. This study evaluates the ability of the trail leading through the gorge to resist trampling disturbance and to minimise the environmental impacts in the wider area of Sucha Bela by keeping tourists from moving off the designated areas. Aspects of trail layout, geological and geomorphological structures, terrain altering during the summer season, and acceptable tourist flow were investigated.The results show the current development would be acceptable in the case of limited off-trail movement. It therefore seems appropriate to review the trail allocation and marking, and to focus on environmental education rather than on limiting tourist visits.

  9. Demonstration with Energy and Daylighting Assessment of Sunlight Responsive Thermochromic (SRT) Window Systems

    Energy Technology Data Exchange (ETDEWEB)

    Broekhuis, Michael; Liposcak, Curtis; Witte, Michael; Henninger, Robert; Zhou, Xiaohui; Petzen, George; Buchanan, Michael; Kumar, Sneh

    2012-03-31

    Pleotint, LLC was able to successfully extrude thermochromic interlayer for use in the fenestration industry. Pleotint has developed a thermochromic sytem that requires two thermochromic colors to make a neutral color when in the tinted state. These two colors were assembled into a single interlayer called a tri-layer prelam by Crown Operations for use in the glass lamination industry. Various locations, orientations, and constructions of thermochromic windows were studied with funds from this contract. Locations included Australia, California, Costa Rica, Indiana, Iowa, Mexico. Installed orientations included vertical and skylight glazing applications. Various constructions included monolithic, double pane, triple pane constructions. A daylighting study was conducted at LinEl Signature. LinEl Signature has a conference room with a sylight roof system that has a west orientation. The existing LinEl Signature conference room had constant tint 40% VLT transparent skylights. Irradiance meters were installed on the interior and exterior sides of a constant tint skylight. After a month and a half of data collection, the irradiance meters were removed and the constant tint skylights were replaced with Pleotint thermochromic skylight windows. The irradiance meters were reinstalled in the same locations and irradiance data was collected. Both data sets were compared. The data showed that there was a linear relationship with exterior and interior irradiance for the existing constant tint skylights. The thermochromic skylights have a non-linear relationship. The thermochromic skylights were able to limit the amount of irradiance that passed through the thermochromic skylight. A second study of the LinEl Signature conference was performed using EnergyPlus to calculate the amount of Illuminance that passed through constant tint skylights as compared to thermochromic skylights. The constant tint skylights transmitted Illuminance is 2.8 times higher than the thermochromic

  10. Modified optical fiber daylighting system with sunlight transportation in free space.

    Science.gov (United States)

    Vu, Ngoc-Hai; Pham, Thanh-Tuan; Shin, Seoyong

    2016-12-26

    We present the design, optical simulation, and experiment of a modified optical fiber daylighting system (M-OFDS) for indoor lighting. The M-OFDS is comprised of three sub-systems: concentration, collimation, and distribution. The concentration part is formed by coupling a Fresnel lens with a large-core plastic optical fiber. The sunlight collected by the concentration sub-system is propagated in a plastic optical fiber and then collimated by the collimator, which is a combination of a parabolic mirror and a convex lens. The collimated beam of sunlight travels in free space and is guided to the interior by directing flat mirrors, where it is diffused uniformly by a distributor. All parameters of the system are calculated theoretically. Based on the designed system, our simulation results demonstrated a maximum optical efficiency of 71%. The simulation results also showed that sunlight could be delivered to the illumination destination at distance of 30 m. A prototype of the M-OFDS was fabricated, and preliminary experiments were performed outdoors. The simulation results and experimental results confirmed that the M-OFDS was designed effectively. A large-scale system constructed by several M-OFDSs is also proposed. The results showed that the presented optical fiber daylighting system is a strong candidate for an inexpensive and highly efficient application of solar energy in buildings.

  11. Cloud and radiance measurements with the VIS/NIR Daylight Whole Sky Imager at Lindenberg (Germany)

    Energy Technology Data Exchange (ETDEWEB)

    Feister, U. [Deutscher Wetterdienst, Meteorologisches Observatorium Lindenberg (Germany); Shields, J. [Scripps Inst. of Oceanography, Univ. of California, San Diego (United States)

    2005-10-01

    Ground-based cloud data acquired with the whole sky imager (WSI) are analyzed in relation to measurements of solar radiation performed at the Lindenberg Meteorological Observatory. Cloud fractions derived by the cloud detection algorithm from WSI images acquired during daylight hours between 2002 and 2004 are compared with conventional cloud observations for the two sites Potsdam and Lindenberg, and also with ceilometer data of cloud-base heights at Lindenberg. The comparison statistics are discussed in the context of different principles of measurement. A few case studies illustrate the strong scattering effect of clouds on solar radiance and irradiance measured at the ground in different spectral regions. Particularly clouds close to the apparent position of the sun lead to strong enhancements of solar diffuse irradiance incident on horizontal planes and hemispheres that substantially exceed corresponding clear-sky values. Irradiances derived from WSI sky radiance fields are shown in comparison to pyranometer data of diffuse irradiance and radiative transfer model calculations performed for clear sky conditions. Examples of spectral sky radiances with moving contrails illustrate the significant enhancement the contrails have compared to clear sky, even though they may have a relatively small direct effect on global irradiance values. As contrails are observed at Lindenberg for about 18 to 19% of daylight hours, and part of them become clouds, the indirect impact of these changes on solar irradiance received at the ground may not be negligible. (orig.)

  12. Development of Optical Fiber-Based Daylighting System and Its Comparison

    Directory of Open Access Journals (Sweden)

    Irfan Ullah

    2015-07-01

    Full Text Available Fiber-optic daylighting systems have been shown to be a promising and effective way to transmit sunlight in the interior space whilst reducing electric lighting energy consumption. To increase efficiency in terms of providing uniform illumination in the interior, the current need is to illuminate optical fiber-bundle with uniform light flux. To this end, we propose a method for achieving collimated light, which illuminates the fiber-bundle uniformly. Light is collected through a parabolic concentrator and focused toward a collimating lens, which distributes the light over each optical fiber. An optics diffusing structure is utilized at the end side of the fiber bundle to spread light in the interior. The results clearly reveal that the efficiency in terms of uniform illumination, which also reduces the heat problem for optical fibers, is improved. Furthermore, a comparison study is conducted between current and previous approaches. As a result, the proposed daylighting system turns out convenient in terms of energy saving and reduction in greenhouse gas emissions.

  13. Light-scattering properties of a Venetian blind slat used for daylighting applications

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Annica M. [Department of Engineering Sciences, Angstroem Laboratory, Uppsala University (Sweden); Jonsson, Jacob C. [Environmental Energy Technology Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2010-12-15

    The low cost, simplicity, and aesthetic appearance of external and internal shading devices, make them commonly used for daylighting and glare-control applications. Shading devices, such as Venetian blinds, screens, and roller shades, generally exhibit light scattering and/or light redirecting properties. This requires the bi-directional scattering distribution function (BSDF) of the material to be known in order to accurately predict the daylight distribution and energy flow through the fenestration system. Acquiring the complete BSDF is not a straightforward task, and to complete the process it is often required that a model is used to complement the measured data. In this project, a Venetian blind slat with a white top surface and a brushed aluminum bottom surface was optically characterized. A goniophotometer and an integrating sphere spectrophotometer were used to determine the angle resolved and hemispherical reflectance of the sample, respectively. The acquired data were fitted to a scattering model providing one Lambertian and one angle dependent description of the surface properties. These were used in combination with raytracing to obtain the complete BSDFs of the Venetian blind system. (author)

  14. Comparative Study of Two Daylighting Analysis Methods with Regard to Window Orientation and Interior Wall Reflectance

    Directory of Open Access Journals (Sweden)

    Yeo Beom Yoon

    2014-09-01

    Full Text Available The accuracy and speed of the daylighting analysis developed for use in EnergyPlus is better than its predecessors. In EnergyPlus, the detailed method uses the Split-flux algorithm whereas the DElight method uses the Radiosity algorithm. Many existing studies have addressed the two methods, either individually or compared with other daylight analysis methods like Ray tracing but still there is lack of detailed comparative study of these two methods. Our previous studies show that the Split-flux method overestimates the illuminance, especially for the areas away from the window. The Radiosity method has the advantage of accurately predicting this illuminance because of how it deals with the diffuse light. For this study, the EnergyPlus model, which has been calibrated using data measured in a real building in previous studies, has also been used. The calibrated model has a south oriented window only. This model is then used to analyze the interior illuminance inside the room for north, west and east orientation of the window by rotating the model and by changing the wall reflectance of the model with south oriented window. Direct and diffuse component of the illuminance as well as the algorithms have been compared for a detailed analysis.

  15. Low levels of vitamin D poorly responsive to daylight exposure in patients with therapy-resistant schizophrenia.

    Science.gov (United States)

    Bogers, Jan P.A.M.; Bostoen, Tijmen; Broekman, Theo G.

    2016-01-01

    Low vitamin D levels are associated with schizophrenia, but the possible association between vitamin D levels and illness severity or duration of exposure to daylight has barely been investigated. To compare vitamin D levels in therapy-refractory severely ill schizophrenia patients and members of staff. To investigate the influence of daylight exposure on vitamin D levels in patients. Vitamin D was measured in patients with therapy-resistant schizophrenia in April, after the winter, and in patients and staff members in June, after an exceptionally sunny spring. Vitamin D levels in April and June were compared in patients, and levels in June were compared in patients and staff. The influence of daylight was taken into account by comparing the time patients spent outdoors during the day with the recommended minimum time for adequate vitamin D synthesis, and by comparing time spent outdoors in patients and staff. Patients had high rates of vitamin D deficiency (79-90%) and lower levels of vitamin D than staff members (p vitamin D levels did not normalize, despite the considerably longer than recommended exposure of the skin to daylight (p vitamin D deficiency of therapy-resistant schizophrenia patients is pronounced and cannot be explained by differences in skin pigmentation or by an inactive, indoor lifestyle on the ward. Even theoretically sufficient exposure of the patients to daylight did not ameliorate the low vitamin D levels. While vitamin D deficiency probably plays a role in somatic health problems, it may also play a role in schizophrenia. Interestingly, exposure to daylight during an unusually sunny spring was not sufficient to correct the vitamin D deficiency seen in the patients. This emphasizes the need to measure and correct vitamin D levels in these patients.

  16. A method for apportionment of natural and anthropogenic contributions to heavy metal loadings in the surface soils across large-scale regions.

    Science.gov (United States)

    Hu, Yuanan; Cheng, Hefa

    2016-07-01

    Quantification of the contributions from anthropogenic sources to soil heavy metal loadings on regional scales is challenging because of the heterogeneity of soil parent materials and high variability of anthropogenic inputs, especially for the species that are primarily of lithogenic origin. To this end, we developed a novel method for apportioning the contributions of natural and anthropogenic sources by combining sequential extraction and stochastic modeling, and applied it to investigate the heavy metal pollution in the surface soils of the Pearl River Delta (PRD) in southern China. On the average, 45-86% of Zn, Cu, Pb, and Cd were present in the acid soluble, reducible, and oxidizable fractions of the surface soils, while only 12-24% of Ni, Cr, and As were partitioned in these fractions. The anthropogenic contributions to the heavy metals in the non-residual fractions, even the ones dominated by natural sources, could be identified and quantified by conditional inference trees. Combination of sequential extraction, Kriging interpolation, and stochastic modeling reveals that approximately 10, 39, 6.2, 28, 7.1, 15, and 46% of the As, Cd, Cr, Cu, Ni, Pb, and Zn, respectively, in the surface soils of the PRD were contributed by anthropogenic sources. These results were in general agreements with those obtained through subtraction of regional soil metal background from total loadings, and the soil metal inputs through atmospheric deposition as well. In the non-residual fractions of the surface soils, the anthropogenic contributions to As, Cd, Cr, Cu, Ni, Pb, and Zn, were 48, 42, 50, 51, 49, 24, and 70%, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Natural and anthropogenic trace metal contamination and load assessment in the Oum Er-Rbia river basin, Morocco

    International Nuclear Information System (INIS)

    Schone, Selina; Zahry, Fatiha; Matschullat, Jorg; Bounakhla, Moussa

    2008-01-01

    Due to natural constraints and its fast socio-economic development Morocco is confronted with serious problems both in terms of water quantity and water quality management. In order to counteract the water quality degradation a comprehensive understanding of the geochemical and hydrological functioning as well as the bahavior of inorganic contaminants in large riverine systems under semiarid conditions shall be developed within the scope of this pilot study. Within the scope of a dissertation project Mrs Zahry has already investigated the physical and geochemical characteristics of the oum Er-Rbia river basin in Morocco. Water, sediment and suspended matter samples were analyzed in order to assess the trace metal contamination of the river. Due to the lack of the local geochemical backgrounds levels the results were normalised to common international standards. But because of the spatial and temporal variability of the geochemical background global standards are not appropriate to answer regional and local problems. Following up the work of Mrs Zahry the project shall for the first time ever in Morocco provide local geochemical backgrounds levels of various media in the large-scale Oum ErRbia river basin to establish regional geochemical standards and to assess the watercourse contamination in terms of anthropogenic contributions of trace metals. The research project will be conducted in cooperation between the CNESTEN, Morocco and the Technical University Bergakademie Freiberg in Germany. The project has started of the aquisation of geo-basis data to develop a sampling strategy. All field investigations (sampling, run-off measurements), analytical work and data analysis will be done in direct collaboration with the Moroccan Scientists [fr

  18. Annual dynamics of daylight variability and contrast a simulation-based approach to quantifying visual effects in architecture

    CERN Document Server

    Rockcastle, Siobhan

    2013-01-01

    Daylight is a dynamic source of illumination in architectural space, creating diverse and ephemeral configurations of light and shadow within the built environment. Perceptual qualities of daylight, such as contrast and temporal variability, are essential to our understanding of both material and visual effects in architecture. Although spatial contrast and light variability are fundamental to the visual experience of architecture, architects still rely primarily on intuition to evaluate their designs because there are few metrics that address these factors. Through an analysis of contemporary

  19. Design methodology and criteria for daylight and thermal comfort in nearly-zero energy office buildings in Nordic climate

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth

    The objective of this PhD thesis was to arrange for an integrated building design with respect to thermal comfort, daylighting and energy use, applicable for office buildings in Nordic climate. In order to achieve this, it is suggested that modelling of mean radiant temperature (MRT) should...... into the simulation tool IDA ICE. Furthermore, the control of solar shading is given attention, since it is a crucial link between the thermal and daylighting performance. The thesis presents results of an occupant survey with 46 subjects, which was carried out to investigate occupants’ preferences towards...

  20. Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed

    Energy Technology Data Exchange (ETDEWEB)

    Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew

    2013-08-31

    Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in a sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the

  1. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.

    2012-11-01

    In desert sunny clear-sky regions solar penetration can become excessive. This can cause non-uniform daylight distribution, glare and high solar heat gain, affecting both visual and thermal comfort. Shading devices, such as solar screens, were usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space under the desert sunny clear-sky. The larger aim is to arrive at efficient solar screen designs that suit the different orientations.The study was divided into three consecutive phases. In phase one, the effect of the two parameters on Daylight Availability was tested. The solar screen was axially rotated by three different angles at 10° increments. Also, the aspect ratio of the screen opening in both horizontal and vertical directions was changed systematically. Simulation was conducted using the annual Daylight Dynamic Performance Metrics (DDPMs). In phase two, the Annual Daylight Glare Probability (DGP) metric was evaluated for the cases that were found adequate in phase one. In the third phase, the annual solar energy transmittance through the screen was calculated for the cases that achieved acceptable performance in the two previous phases in order to identify the more energy efficient screens.Solar screens with openings having horizontal aspect ratios were found to be the most effective, while those with vertical aspect ratios were achieved the lowest performance. In the North orientation, since almost all the cases that were tested in this research provided acceptable daylighting performance, the designer now have a variety of options to choose from. Preference should be given to screen openings of horizontal aspect ratios, especially the 12:1 and 18:1 (H:V) screens that achieved the best performance where 92% of the space was " daylit" in comparison with only 53

  2. Development and in vitro characterization of poly(lactide-co-glycolide microspheres loaded with an antibacterial natural drug for the treatment of long-term bacterial infections

    Directory of Open Access Journals (Sweden)

    Reinbold J

    2016-09-01

    Full Text Available Jochen Reinbold,1 Teresa Hierlemann,1 Helena Hinkel,1 Ingrid Müller,2 Martin E Maier,3 Tobias Weindl,4 Christian Schlensak,1 Hans Peter Wendel,1 Stefanie Krajewski1 1Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Tuebingen, Tuebingen, 2Department of Pharmaceutical Engineering, Albstadt-Sigmaringen University, Sigmaringen, 3Institute of Organic Chemistry, University Tuebingen, Tuebingen, 4Aimecs GmbH, Pfarrkirchen, Germany Abstract: Biodegradable polymers, especially poly(lactide-co-glycolide (PLGA, have good biocompatibility and toxicological properties. In combination with active ingredients, a specialized drug delivery system can be generated. The aim of the present study was to develop a drug delivery system consisting of PLGA microspheres loaded with the natural active ingredient totarol, which has several antimicrobial mechanisms. Totarol, isolated from the Podocarpus totara tree, was purified using column chromatography, and the eluate was checked for purity using thin layer chromatography. The spherically shaped microspheres with mean diameters of 147.21±3.45 µm and 131.14±3.69 µm (totarol-loaded and -unloaded microspheres, respectively were created using the single emulsion evaporation method. Furthermore, the encapsulation efficiency, in a range of 84.72%±6.68% to 92.36%±0.99%, was measured via UV/vis spectroscopy. In a 90-day in vitro drug release study, the release of totarol was investigated by UV/vis spectroscopy as well, showing a release of 53.76%. The toxicity on cells was determined using BJ fibroblasts or Human Embryonic Kidney cells and an 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide assay, which showed no influence on the cell growth. The minimal inhibitory concentration was ascertained. A totarol concentration between 64 µg/mL and 128 µg/mL was necessary to inhibit the bacterial growth over a period of 24 hours. Biofilm formation on the surface of totarol-loaded

  3. Occurrence of Leishmania infantum in the central nervous system of naturally infected dogs: Parasite load, viability, co-infections and histological alterations.

    Science.gov (United States)

    Oliveira, Valéria da Costa; Boechat, Viviane Cardoso; Mendes Junior, Artur Augusto Velho; Madeira, Maria de Fátima; Ferreira, Luiz Claudio; Figueiredo, Fabiano Borges; Campos, Monique Paiva; de Carvalho Rodrigues, Francisco das Chagas; Carvalhaes de Oliveira, Raquel de Vasconcellos; Amendoeira, Maria Regina Reis; Menezes, Rodrigo Caldas

    2017-01-01

    Zoonotic visceral leishmaniasis is caused by the protozoan Leishmania infantum and little is known about the occurrence and pathogenesis of this parasite in the CNS. The aims of this study were to evaluate the occurrence, viability and load of L. infantum in the CNS, and to identify the neurological histological alterations associated with this protozoan and its co-infections in naturally infected dogs. Forty-eight Leishmania-seropositive dogs from which L. infantum was isolated after necropsy were examined. Cerebrospinal fluid (CSF) samples were analyzed by parasitological culture, quantitative real-time PCR (qPCR) and the rapid immunochromatographic Dual Path Platform test. Brain, spinal cord and spleen samples were submitted to parasitological culture, qPCR, and histological techniques. Additionally, anti-Toxoplasma gondii and anti-Ehrlichia canis antibodies in serum and distemper virus antigens in CSF were investigated. None of the dogs showed neurological signs. All dogs tested positive for L. infantum in the CNS. Viable forms of L. infantum were isolated from CSF, brain and spinal cord in 25% of the dogs. Anti-L. infantum antibodies were detected in CSF in 61% of 36 dogs. Inflammatory histological alterations were observed in the CNS of 31% of the animals; of these, 66% were seropositive for E. canis and/or T. gondii. Amastigote forms were associated with granulomatous non-suppurative encephalomyelitis in a dog without evidence of co-infections. The highest frequency of L. infantum DNA was observed in the brain (98%), followed by the spinal cord (96%), spleen (95%), and CSF (50%). The highest L. infantum load in CNS was found in the spinal cord. These results demonstrate that L. infantum can cross the blood-brain barrier, spread through CSF, and cause active infection in the entire CNS of dogs. Additionally, L. infantum can cause inflammation in the CNS that can lead to neurological signs with progression of the disease.

  4. Occurrence of Leishmania infantum in the central nervous system of naturally infected dogs: Parasite load, viability, co-infections and histological alterations.

    Directory of Open Access Journals (Sweden)

    Valéria da Costa Oliveira

    Full Text Available Zoonotic visceral leishmaniasis is caused by the protozoan Leishmania infantum and little is known about the occurrence and pathogenesis of this parasite in the CNS. The aims of this study were to evaluate the occurrence, viability and load of L. infantum in the CNS, and to identify the neurological histological alterations associated with this protozoan and its co-infections in naturally infected dogs. Forty-eight Leishmania-seropositive dogs from which L. infantum was isolated after necropsy were examined. Cerebrospinal fluid (CSF samples were analyzed by parasitological culture, quantitative real-time PCR (qPCR and the rapid immunochromatographic Dual Path Platform test. Brain, spinal cord and spleen samples were submitted to parasitological culture, qPCR, and histological techniques. Additionally, anti-Toxoplasma gondii and anti-Ehrlichia canis antibodies in serum and distemper virus antigens in CSF were investigated. None of the dogs showed neurological signs. All dogs tested positive for L. infantum in the CNS. Viable forms of L. infantum were isolated from CSF, brain and spinal cord in 25% of the dogs. Anti-L. infantum antibodies were detected in CSF in 61% of 36 dogs. Inflammatory histological alterations were observed in the CNS of 31% of the animals; of these, 66% were seropositive for E. canis and/or T. gondii. Amastigote forms were associated with granulomatous non-suppurative encephalomyelitis in a dog without evidence of co-infections. The highest frequency of L. infantum DNA was observed in the brain (98%, followed by the spinal cord (96%, spleen (95%, and CSF (50%. The highest L. infantum load in CNS was found in the spinal cord. These results demonstrate that L. infantum can cross the blood-brain barrier, spread through CSF, and cause active infection in the entire CNS of dogs. Additionally, L. infantum can cause inflammation in the CNS that can lead to neurological signs with progression of the disease.

  5. Daylight for energy-saving lamps. Recognizing with lighting sources free of charge; Tageslicht vor Energiesparlampen. Kostenlos verfuegbare Lichtquellen einplanen

    Energy Technology Data Exchange (ETDEWEB)

    David, Holger

    2010-07-01

    With saving energy in the lighting, politics, economics and private households set on compact fluorescent lamps, so called energy-saving lamps. A more economical and pollution free alternative is the increased use of daylight, which is free of charge and felt more pleasant by humans.

  6. Switching From Conventional Photodynamic Therapy to Daylight Photodynamic Therapy For Actinic Keratoses: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Tomás-Velázquez, A; Redondo, P

    2017-05-01

    Actinic keratosis is a precursor lesion to the most common nonmelanoma skin cancer. Conventional photodynamic therapy (PDT) has been shown to be effective, but the procedure is time-consuming, can be very painful, and requires infrastructure. These shortcomings led to the emergence of daylight PDT. To obtain a global estimate of efficacy, we undertook a systematic literature review and performed a meta-analysis of the available evidence on the efficacy and safety of daylight PDT as compared to conventional PDT in the treatment of actinic keratosis and/or field cancerization. The conclusion is that the difference in efficacy is clinically negligible (global estimate of the mean response rate difference, -3.69%; 95% CI, -6.54% to -0.84%). The adverse effects of daylight PDT are mild and localized (79% of patients report no discomfort), and patients report less pain (P<.001). Daylight PDT gives good to excellent cosmetic results in more than 90% of patients, and patient satisfaction is greater (P<.001). Copyright © 2016 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Photoageing of Baltic amber-influence of daylight radiation behind window glass on surface colour and chemistry

    DEFF Research Database (Denmark)

    Shashoua, Yvonne

    2011-01-01

    The aim of this study was to provide evidence about the interaction between Baltic amber and daylight behind window glass, essential to understanding the mechanisms by which the material degrades in museum environments and to propose techniques for preventive conservation based on the control...

  8. Students' Perception of Daylight Illumination in the School Workshop as a Determinant for Effective Students' Task Performance in Workshop Practice

    Science.gov (United States)

    Amasuomo, Japo Oweikeye Morto; Alio, Abigail Ngozi

    2013-01-01

    The study investigated daylight illumination in the school workshop as a determinant for effective students' task performance in workshop practice. 183 NCE Technical students in 300 Level which comprised of 73 and 112 students from Federal Colleges of Education (Technical), Asaba and Omoku, Nigeria respectively during the 2008/2009 academic…

  9. Lost sleep and cyberloafing: Evidence from the laboratory and a daylight saving time quasi-experiment.

    Science.gov (United States)

    Wagner, David T; Barnes, Christopher M; Lim, Vivien K G; Ferris, D Lance

    2012-09-01

    The Internet is a powerful tool that has changed the way people work. However, the ubiquity of the Internet has led to a new workplace threat to productivity-cyberloafing. Building on the ego depletion model of self-regulation, we examine how lost and low-quality sleep influence employee cyberloafing behaviors and how individual differences in conscientiousness moderate these effects. We also demonstrate that the shift to Daylight Saving Time (DST) results in a dramatic increase in cyberloafing behavior at the national level. We first tested the DST-cyberloafing relation through a national quasi-experiment, then directly tested the relation between sleep and cyberloafing in a closely controlled laboratory setting. We discuss the implications of our findings for theory, practice, and future research.

  10. Dynamic window daylighting systems: electropolymeric technology for solar responsive building envelopes

    Science.gov (United States)

    Krietemeyer, Elizabeth A.; Smith, Shane I.; Dyson, Anna H.

    2011-04-01

    Human health and energy problems associated with the lack of control of sunlight in contemporary buildings have necessitated research into dynamic windows for energy efficient buildings. Existing window technologies have made moderate progress towards greater energy performance for facades but remain limited in their response to dynamic solar conditions, building energy requirements, and variable user preferences for visual comfort. Recent developments in electropolymeric display technology provide opportunities to transfer electroactive polymers to windows that can achieve high levels of geometric and spectral selectivity through the building envelope in order to meet the lighting, thermal and user requirements of occupied spaces. Experimental simulations that investigate daylight quality, energy performance, and architectural effects of electropolymeric glazing technology are presented.

  11. Discomfort glare with complex fenestration systems and the impact on energy use when using daylighting control

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Sabine; McNeil, Andrew; Lee, Eleanor S.; Kalyanam, Raghuram

    2015-11-03

    Glare is a frequent issue in highly glazed buildings. A modelling approach is presented that uses discomfort glare probability and discomfort glare index as metrics to determine occupants’ behaviour. A glare control algorithm that actuated an interior shade for glare protection based on the predicted perception was implemented in a building simulation program. A reference case with a state-of-the-art base glazing was compared to the same glazing but with five different complex fenestration systems, i.e., exterior shades. The windows with exterior shades showed significant variations in glare frequencies. Energy use intensity in a prototypical office building with daylighting controls was greatly influenced for the systems with frequent glare occurrence. While the base glazing could benefit from glare control, some of the exterior shades showed significantly greater energy use when discomfort glare-based operation of interior shades was considered.

  12. Impact of daylight savings time on spontaneous pregnancy loss in in vitro fertilization patients.

    Science.gov (United States)

    Liu, Constance; Politch, Joseph A; Cullerton, Evan; Go, Kathryn; Pang, Samuel; Kuohung, Wendy

    2017-01-01

    Transition into daylight savings time (DST) has studied negative impacts on health, but little is known regarding impact on fertility. This retrospective cohort study evaluates DST impact on pregnancy and pregnancy loss rates in 1,654 autologous in vitro fertilization cycles (2009 to 2012). Study groups were identified based on the relationship of DST to embryo transfer. Pregnancy rates were similar in Spring and Fall (41.4%, 42.2%). Pregnancy loss rates were also comparable between Spring and Fall (15.5%, 17.1%), but rates of loss were significantly higher in Spring when DST occurred after embryo transfer (24.3%). Loss was marked in patients with a history of prior spontaneous pregnancy loss (60.5%).

  13. Window Material Daylighting Performance Assessment Algorithm: Comparing Radiosity and Split-Flux Methods

    Directory of Open Access Journals (Sweden)

    Yeo Beom Yoon

    2014-04-01

    Full Text Available Windows are the primary aperture to introduce solar radiation to the interior space of a building. This experiment explores the use of EnergyPlus software for analyzing the illuminance level on the floor of a room with reference to its distance from the window. For this experiment, a double clear glass window has been used. The preliminary modelling in EnergyPlus showed a consistent result with the experimentally monitored data in real time. EnergyPlus has two mainly used daylighting algorithms: DElight method employing radiosity technique and Detailed method employing split-flux technique. Further analysis for illuminance using DElight and Detailed methods showed significant difference in the results. Finally, we compared the algorithms of the two analysis methods in EnergyPlus.

  14. Impact of daylight saving time on road traffic collision risk: a systematic review.

    Science.gov (United States)

    Carey, Rachel N; Sarma, Kiran M

    2017-07-02

    Bills have been put forward in the UK and Republic of Ireland proposing a move to Central European Time (CET). Proponents argue that such a change will have benefits for road safety, with daylight being shifted from the morning, when collision risk is lower, to the evening, when risk is higher. Studies examining the impact of daylight saving time (DST) on road traffic collision risk can help inform the debate on the potential road safety benefits of a move to CET. The objective of this systematic review was to examine the impact of DST on collision risk. Major electronic databases were searched, with no restrictions as to date of publication (the last search was performed in January 2017). Access to unpublished reports was requested through an international expert group. Studies that provided a quantitative analysis of the effect of DST on road safety-related outcomes were included. The primary outcomes of interest were road traffic collisions, injuries and fatalities. Twenty-four studies met the inclusion criteria. Seventeen examined the short-term impact of transitions around DST and 12 examined long-term effects. Findings from the short-term studies were inconsistent. The long-term findings suggested a positive effect of DST. However, this cannot be attributed solely to DST, as a range of road collision risk factors vary over time. The evidence from this review cannot support or refute the assertion that a permanent shift in light from morning to evening will have a road safety benefit. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Economic analysis of the daylight-linked lighting control system in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, In-Ho; Nam, Eun-Ji [Department of Architectural Engineering, College of Engineering, Dongguk University, 26-3, Pil-dong, Chung-gu, Seoul 100-715 (Korea)

    2010-08-15

    The objective of this study is to perform an economic analysis of the daylight-linked automatic on/off lighting control system installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the energy cost was calculated by using the daylight and building energy analysis simulation. When the lighting control was utilized, an economic analysis was performed using a payback period that was calculated by comparing the initial cost of installing the lighting control system with the annual energy cost which was reduced thanks to the application of the lighting control. The results showed that the lighting energy consumption, when the lighting control was applied, was reduced by an average of 30.5% compared with the case that there was not lighting control applied. Also, the result for total energy consumption showed that, when lighting control was applied, this was reduced by 8.5% when the glazing ratio was 100%, 8.2% for 80%, and 7.6% for 60% when compared to non-application. The payback period was analyzed in terms of the number of floors in a building; 10 floors, 20 floors, 30 floors, and 40 floors. Hence, the building with 40 floors and glazing ratio 100% resulted in the shortest payback period of 8.8 years, the building with 10 floors and glazing ratio 60% resulted in the longest period of 12.7 years. In other words, the larger the glazing ratio and the number of building floors are, the shorter the payback period is. (author)

  16. Functionalized graphene quantum dots loaded with free radicals combined with liquid chromatography and tandem mass spectrometry to screen radical scavenging natural antioxidants from Licorice and Scutellariae.

    Science.gov (United States)

    Wang, Guoying; Niu, XiuLi; Shi, Gaofeng; Chen, Xuefu; Yao, Ruixing; Chen, Fuwen

    2014-12-01

    A novel screening method was developed for the detection and identification of radical scavenging natural antioxidants based on a free radical reaction combined with liquid chromatography with tandem mass spectrometry. Functionalized graphene quantum dots were prepared for loading free radicals in the complex screening system. The detection was performed with and without a preliminary exposure of the samples to specific free radicals on the functionalized graphene quantum dots, which can facilitate charge transfer between free radicals and antioxidants. The difference in chromatographic peak areas was used to identify potential antioxidants. This is a novel approach to simultaneously evaluate the antioxidant power of a component versus a free radical, and to identify it in a vegetal matrix. The structures of the antioxidants in the samples were identified using tandem mass spectrometry and comparison with standards. Fourteen compounds were found to possess potential antioxidant activity, and their free radical scavenging capacities were investigated. The order of scavenging capacity of 14 compounds was compared according to their free radical scavenging rate. 4',5,6,7-Tetrahydroxyflavone (radical scavenging rate: 0.05253 mL mg(-1) s(-1) ) showed the strongest capability for scavenging free radicals. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Evaluation of viremia, proviral load and cytokine profile in naturally feline immunodeficiency virus infected cats treated with two different protocols of recombinant feline interferon omega.

    Science.gov (United States)

    Leal, Rodolfo O; Gil, Solange; Duarte, Ana; McGahie, David; Sepúlveda, Nuno; Niza, Maria M R E; Tavares, Luís

    2015-04-01

    This study assesses viremia, provirus and blood cytokine profile in naturally FIV-infected cats treated with two distinct protocols of interferon omega (rFeIFN-ω). Samples from FIV-cats previously submitted to two single-arm studies were used: 7/18 received the licensed/subcutaneous protocol (SC) while 11/18 were treated orally (PO). Viremia, provirus and blood mRNA expression of interleukin (IL)-1, IL-4, IL-6, IL-10, IL-12p40, Interferon-γ and Tumor Necrosis Factor-α were monitored by Real-Time qPCR. Concurrent plasma levels of IL-6, IL-12p40 and IL-4 were assessed by ELISA. IL-6 plasma levels decreased in the SC group (p = 0.031). IL-6 mRNA expression (p = 0.037) decreased in the PO group, albeit not sufficiently to change concurrent plasma levels. Neither viremia nor other measured cytokines changed with therapy. Proviral load increased in the SC group (p = 0.031), which can be justified by a clinically irrelevant increase of lymphocyte count. Independently of the protocol, rFeIFN-ω seems to act on innate immunity by reducing pro-inflammatory stimulus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Energy optimised lighting in buildings with simultaneous improvement of quality of life by daylight utilisation and innovative lamps and ballast techniques; Energieoptimierte Beleuchtung bei gleichzeitiger Verbesserung der Lebensqualitaet durch Nutzung von Tageslicht und neuer Lampen- und Vorschalttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Kaase, Heinrich; Aydinli, Sirri; Gramm, Stefan; Thiel, Stefan [Technische Universitaet Berlin, Fakultaet IV Elektrotechnik und Informatik, FG Lichttechnik, Berlin (Germany); De Boer, Jan; Erhorn, Hans [Fraunhofer-Institut fuer Bauphysik, Stuttgart (Germany); Kuhn, Tilman; Wienold, Jan [Fraunhofer-Institut fuer Solare Energiesysteme, Freiburg (Germany); Hillmann, Gustav; Korolkow, Margarethe [IBUS GmbH, Berlin (Germany); Piazena, Helmut [Universitaetsklinikum Charite, Berlin (Germany)

    2012-06-15

    The scientific and technical goals of this project were developed in five parts. The individual topics arising from current issues, they still have a generally applicable nature. The consortium has worked on the following subprojects: (1) Development of a measurement technique to determine energy and photometric key figures of daylight components with a round robin test with three institutes. (2) Implementation of a detailed evaluation and documentation process for daylighting of interior spaces in different climate zones. (3) For lighting control in private living areas a ''Power Line Carrier Communication'' system has been evaluated and the advantages of a wireless transmission system were identified. (4) In a home for elderly quantitative studies on the well-being, for the fulfillment of visual tasks and the capability of melatonin suppression at different scenarios of general lighting with two different color temperatures of lamps (''warm white'' with TCP = 3000 K and ''cold white daylight'' with TCP = 6500 K) and vertical illuminance at the eyes of the subjects between 100 lx and 700 lx were performed. (5) For two school buildings in Berlin, the final energy consumption of the existing lighting system, the reference building and a re-planning were determined. It became clear in both examples that the existing lighting system exceeds the permitted value (EnEV 2009) by far. A good redesign, however, can be significantly less than the maximum allowed value. These studies were accompanied by a one-year monitoring of energy consumption. A cross-sectional analysis of 48 schools with a total of 86 buildings shows a substantial need for renovation of school buildings that were built before 1990.

  19. A randomized, multicentre study of directed daylight exposure times of 1½ vs. 2½ h in daylight-mediated photodynamic therapy with methyl aminolaevulinate in patients with multiple thin actinic keratoses of the face and scalp

    DEFF Research Database (Denmark)

    Wiegell, Stine; Fabricius, S; Stender, I M

    2011-01-01

    Actinic keratoses (AKs) are common dysplastic skin lesions that may differentiate into invasive squamous cell carcinomas. Although a superior cosmetic outcome of photodynamic therapy (PDT) is advantageous compared with equally effective treatments such as cryotherapy and curettage, the inconvenie......, the inconvenience of clinic attendance and discomfort during therapy are significant drawbacks. Daylight-mediated PDT could potentially reduce these and may serve as an alternative to conventional PDT....

  20. Daylighting analysis of rooflights through model measurements in the artificial sky

    Energy Technology Data Exchange (ETDEWEB)

    Filetoht, Levente I. [University of Technnology and Economics, Budapest, Hungary (Hungary)

    2000-07-01

    In investigating the daylighting of rooflights, it can be assumed that they are behaving as luminaires-having a major role in the lighting features of the interior space. Until now there is not enough precise information on these daylighting systems, and because of this, it is difficult to predict precisely the quality and quantity of illuminance and the light distribution in the interior. The exact behavior of the rooflights are complex and sophisticated. Their features are based on their geometry, reflectance and transmittance of their non-transparent, transparent and translucent surfaces. The effect of these features can not be predicted of calculated using the traditional mathematical methods. I am investigating roof-lighting systems taking into account the complex effects of their parts, using a completely new method based on a series of model measurements under artificial sky. Investigating the roof-light as a complex system which consist of relatively large surfaces and the effects of surfaces on other surfaces. Considering the different illuminance fields of the different types of roof-lighting systems. I will be able to determine the light distribution and efficiency of the system as well. The results of this research will lead to the development of a new computer software which is beyond the scope of this paper. [Spanish] Al investigar la iluminacion de luz de dia de luces de techo puede suponerse que se estan comportando como luminarias teniendo un papel principal en las caracteristicas de iluminacion del espacio interior. Hasta ahora no existe ninguna informacion precisa de estos sistemas de iluminacion de dia y a causa de ello es dificil predecir con precision la calidad y cantidad de iluminancia y la distribucion de la luz en el interior. El comportamiento exacto de las luces de techo es complejo y sofisticado. Sus caracteristicas estan basadas en su geometria, reflectancia y trasmitancia de sus superficies no transparentes, transparentes y

  1. Loading of free radicals on the functional graphene combined with liquid chromatography-tandem mass spectrometry screening method for the detection of radical-scavenging natural antioxidants.

    Science.gov (United States)

    Wang, Guoying; Shi, Gaofeng; Chen, Xuefu; Chen, Fuwen; Yao, Ruixing; Wang, Zhenju

    2013-11-13

    A novel free radical reaction combined with liquid chromatography electrospray ionization tandem mass spectrometry (FRR-LC-PDA-ESI/APCI-MS/MS) screening method was developed for the detection and identification of radical-scavenging natural antioxidants. Functionalized graphene was prepared by chemical method for loading free radicals (superoxide radical, peroxyl radical and PAHs free radical). Separation was performed with and without a preliminary exposure of the sample to specific free radicals on the functionalized graphene, which can facilitate reaction kinetics (charge transfers) between free radicals and potential antioxidants. The difference in chromatographic peak areas is used to identify potential antioxidants. The structure of the antioxidants in one sample (Swertia chirayita) is identified using MS/MS and comparison with standards. Thirteen compounds were found to possess potential antioxidant activity, and their free radical-scavenging capacities were investigated. The thirteen compounds were identified as 1,3,5-trihydroxyxanthone-8-O-β-D-glucopyranoside (PD1), norswertianin (PD2), 1,3,5,8-tetrahydroxyxanthone (PD3), 3, 3', 4', 5, 8-penta hydroxyflavone-6-β-D-glucopyranosiduronic acid-6'-pentopyranose-7-O-glucopyranoside (PD4), 1,5,8-trihydroxy-3-methoxyxanthone (PD5), swertiamarin (PS1), 2-C-β-D-glucopyranosyl-1,3,7-trihydroxylxanthone (PS2), 1,3,7-trihydroxylxanthone-8-O-β-D-glucopyranoside (PL1), 1,3,8-trihydroxyl xanthone-5-O-β-D-glucopyranoside (PL2), 1,3,7-trihydroxy-8-methoxyxanthone (PL3), 1,2,3-trihydroxy-7,8-dimethoxyxanthone (PL4), 1,8-dihydroxy-2,6-dimethoxy xanthone (PL5) and 1,3,5,8-tetramethoxydecussatin (PL6). The reactivity and SC50 values of those compounds were investigated, respectively. PD4 showed the strongest capability for scavenging PAHs free radical; PL4 showed prominent scavenging capacities in the lipid peroxidation processes; it was found that all components in S. chirayita exhibited weak reactivity in the superoxide

  2. Impact of façade window design on energy, daylighting and thermal comfort in nearly zero-energy houses

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Skarning, Gunnlaug Cecilie Jensen; Hviid, Christian Anker

    2015-01-01

    a solution space defined by targets for daylighting and thermal comfort. In contrast with existing guidelines, the results show an upper limit for energy savings and utilisation of solar gains in south-oriented rooms. Instead, low U-values are needed in both north- and south oriented rooms before large......Appropriate window solutions are decisive for the design of 'nearly zero-energy' buildings with healthy and comfortable indoor environment. This paper focuses on the relationship between size, orientation and glazing properties of façade windows for different side-lit room geometries in Danish...... 'nearly zero-energy' houses. The effect of these parameters on space heating demand, daylighting and thermal environment is evaluated by means of EnergyPlus and DAYSIM and presented in charts illustrating how combinations of design parameters with minimum space heating demand can be selected within...

  3. A geostatistical analysis of IBTS data for age 2 North Sea haddock ( Melanogrammus aeglefinus ) considering daylight effects

    DEFF Research Database (Denmark)

    Wieland, Kai; Rivoirard, J.

    2001-01-01

    to ordinary kriging being most pronounced for years characterized by a high portion of night hauls and a low mean catch rate at night. This demonstrates that external drift kriging with a day/night indicator but preferably with time of day is capable of compensating successfully for daylight effects...... are included in the estimation without any correction for possible daylight effects. In the present study, ordinary kriging was used to correct for sampling irregularities and external drift kriging with a day/night indicator or a cosine function of time of day was applied to account additionally for diurnal...... differences in the catch rates. Only minor differences between the standard indices and the abundance estimates obtained by ordinary kriging were found. In contrast, the external drift kriging, particularly with time of day, yielded higher estimates of mean abundance for all years with the differences...

  4. Light-scattering properties of a woven shade-screen material used for daylighting and solar heat-gain control

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Jacob; Jonsson, Jacob C.; Lee, Eleanor S.; Rubin, Mike

    2008-08-01

    Shade-screens are widely used in commercial buildings as a way to limit the amount of direct sunlight that can disturb people in the building. The shade screens also reduce the solar heat-gain through glazing the system. Modern energy and daylighting analysis software such as EnergyPlus and Radiance require complete scattering properties of the scattering materials in the system. In this paper a shade screen used in the LBNL daylighting testbed is characterized using a photogoniometer and a normal angle of incidence integrating sphere. The data is used to create a complete bi-directional scattering distribution function (BSDF) that can be used in simulation programs. The resulting BSDF is compared to a model BADFs, both directly and by calculating the solar heat-gain coefficient for a dual pane system using Window 6.

  5. Modeling Performance of an Airborne Infrared Sensor Used by a Man-in-the-Loop in Tactical Aircraft during Daylight Operations

    National Research Council Canada - National Science Library

    Harder, James

    1998-01-01

    .... The best monochromatic tactical aircraft displays are contrast limited during daylight operations and are able to reproduce only a fraction of the available dynamic range of current generation IR imaging sensors...

  6. Balancing the daylighting and energy performance of solar screens in residential desert buildings: Examination of screen axial rotation and opening aspect ratio

    KAUST Repository

    Sabry, Hanan; Sherif, Ahmed; Gadelhak, Mahmoud; Aly, Mohamed

    2014-01-01

    Solar screens are typically used to control solar access into building spaces. They proved their usefulness in improving the daylighting and energy performance of buildings in the hot arid desert environments which are endowed with abundance

  7. Energy Savings by Using Daylight for Basic Urban Shapes : With a Case Study of Three Different Street Types

    OpenAIRE

    Sundborg, Bengt

    2016-01-01

    During winter the sun is in short supply. But research at KTH shows that solar radiation can be facilitated while energy consumption for lighting is reduced. This provided that the buildings are appropriately designed. But, unfortunately, the sunlight is often not taken into account and the results are the opposite. The energy savings depend on good town planning where the daylight is accessible for longer periods of time during the day, both indoors and outdoors. Then, the periods of use for...

  8. Enhanced Photocatalytic Degradation of Methyl Orange Dye under the Daylight Irradiation over CN-TiO₂ Modified with OMS-2.

    Science.gov (United States)

    Hassan, Mohamed Elfatih; Chen, Jing; Liu, Guanglong; Zhu, Duanwei; Cai, Jianbo

    2014-12-12

    In this study, CN-TiO₂ was modified with cryptomelane octahedral molecular sieves (OMS-2) by the sol-gel method based on the self-assembly technique to enhance its photocatalytic activity under the daylight irradiation. The synthesized samples were characterized by X-ray diffraction (XRD), UV-vis spectroscopy, Fourier transform infrared spectroscopy (FT-IR) and porosimeter analysis. The results showed that the addition of OMS-2 in the sol lead to higher Brunauer-Emmett-Teller (BET) surface area, pore volume, porosity of particle after heat treatment and the specific surface area, porosity, crystallite size and pore size distribution could be controlled by adjusting the calcination temperature. Compared to the CN-TiO₂-400 sample, CN-TiO₂/OMS-2-400 exhibited greater red shift in absorption edge of samples in visible region due to the OMS-2 coated. The enhancement of photocatalytic activity of CN-TiO₂/OMS-2 composite photocatalyst was subsequently evaluated for the degradation of the methyl orange dye under the daylight irradiation in water. The results showed that the methyl orange dye degradation rate reach to 37.8% for the CN-TiO₂/OMS-2-400 sample under the daylight irradiation for 5 h, which was higher than that of reference sample. The enhancement in daylight photocatalytic activities of the CN-TiO₂/OMS samples could be attributed to the synergistic effects of OMS-2 coated, larger surface area and red shift in adsorption edge of the prepared sample.

  9. Establishment and verification of solar radiation calculation model of glass daylighting roof in hot summer and warm winter zone in China

    OpenAIRE

    Zheng, Caidan; Wu, Peihao; Costanzo, Vincenzo; Wang, Yuchen; Yang, Xiaokun

    2017-01-01

    In this paper, solar heat gain through glass daylighting roof is deeply studied by theoretical calculation method, taking Guangzhou in the Hot Summer and Warm Winter (HSWW) zone as an example. The direct solar radiation is calculated by Bouguer formula whereas the diffuse solar radiation is calculated by Berlage formula, representing the basis for the calculation method of the solar radiation intensity through the glass daylighting roof. Through the establishment of solar radiation calculatio...

  10. Exposure to Non-Extreme Solar UV Daylight: Spectral Characterization, Effects on Skin and Photoprotection

    Directory of Open Access Journals (Sweden)

    Claire Marionnet

    2014-12-01

    Full Text Available The link between chronic sun exposure of human skin and harmful clinical consequences such as photo-aging and skin cancers is now indisputable. These effects are mostly due to ultraviolet (UV rays (UVA, 320–400 nm and UVB, 280–320 nm. The UVA/UVB ratio can vary with latitude, season, hour, meteorology and ozone layer, leading to different exposure conditions. Zenithal sun exposure (for example on a beach around noon under a clear sky can rapidly induce visible and well-characterized clinical consequences such as sunburn, predominantly induced by UVB. However, a limited part of the global population is exposed daily to such intense irradiance and until recently little attention has been paid to solar exposure that does not induce any short term clinical impact. This paper will review different studies on non-extreme daily UV exposures with: (1 the characterization and the definition of the standard UV daylight and its simulation in the laboratory; (2 description of the biological and clinical effects of such UV exposure in an in vitro reconstructed human skin model and in human skin in vivo, emphasizing the contribution of UVA rays and (3 analysis of photoprotection approaches dedicated to prevent the harmful impact of such UV exposure.

  11. Exposure to non-extreme solar UV daylight: spectral characterization, effects on skin and photoprotection.

    Science.gov (United States)

    Marionnet, Claire; Tricaud, Caroline; Bernerd, Françoise

    2014-12-23

    The link between chronic sun exposure of human skin and harmful clinical consequences such as photo-aging and skin cancers is now indisputable. These effects are mostly due to ultraviolet (UV) rays (UVA, 320-400 nm and UVB, 280-320 nm). The UVA/UVB ratio can vary with latitude, season, hour, meteorology and ozone layer, leading to different exposure conditions. Zenithal sun exposure (for example on a beach around noon under a clear sky) can rapidly induce visible and well-characterized clinical consequences such as sunburn, predominantly induced by UVB. However, a limited part of the global population is exposed daily to such intense irradiance and until recently little attention has been paid to solar exposure that does not induce any short term clinical impact. This paper will review different studies on non-extreme daily UV exposures with: (1) the characterization and the definition of the standard UV daylight and its simulation in the laboratory; (2) description of the biological and clinical effects of such UV exposure in an in vitro reconstructed human skin model and in human skin in vivo, emphasizing the contribution of UVA rays and (3) analysis of photoprotection approaches dedicated to prevent the harmful impact of such UV exposure.

  12. Effect of daylight saving time on lighting energy use: A literature review

    International Nuclear Information System (INIS)

    Aries, Myriam B.C.; Newsham, Guy R.

    2008-01-01

    The principal reason for introducing (and extending) daylight saving time (DST) was, and still is, projected energy savings, particularly for electric lighting. This paper presents a literature review concerning the effects of DST on energy use. Simple estimates suggest a reduction in national electricity use of around 0.5%, as a result of residential lighting reduction. Several studies have demonstrated effects of this size based on more complex simulations or on measured data. However, there are just as many studies that suggest no effect, and some studies suggest overall energy penalties, particularly if gasoline consumption is accounted for. There is general consensus that DST does contribute to an evening reduction in peak demand for electricity, though this may be offset by an increase in the morning. Nevertheless, the basic patterns of energy use, and the energy efficiency of buildings and equipment have changed since many of these studies were conducted. Therefore, we recommend that future energy policy decisions regarding changes to DST be preceded by high-quality research based on detailed analysis of prevailing energy use, and behaviours and systems that affect energy use. This would be timely, given the extension to DST underway in North America in 2007

  13. Robustness of circadian clocks to daylight fluctuations: hints from the picoeucaryote Ostreococcus tauri.

    Directory of Open Access Journals (Sweden)

    Quentin Thommen

    Full Text Available The development of systemic approaches in biology has put emphasis on identifying genetic modules whose behavior can be modeled accurately so as to gain insight into their structure and function. However, most gene circuits in a cell are under control of external signals and thus, quantitative agreement between experimental data and a mathematical model is difficult. Circadian biology has been one notable exception: quantitative models of the internal clock that orchestrates biological processes over the 24-hour diurnal cycle have been constructed for a few organisms, from cyanobacteria to plants and mammals. In most cases, a complex architecture with interlocked feedback loops has been evidenced. Here we present the first modeling results for the circadian clock of the green unicellular alga Ostreococcus tauri. Two plant-like clock genes have been shown to play a central role in the Ostreococcus clock. We find that their expression time profiles can be accurately reproduced by a minimal model of a two-gene transcriptional feedback loop. Remarkably, best adjustment of data recorded under light/dark alternation is obtained when assuming that the oscillator is not coupled to the diurnal cycle. This suggests that coupling to light is confined to specific time intervals and has no dynamical effect when the oscillator is entrained by the diurnal cycle. This intriguing property may reflect a strategy to minimize the impact of fluctuations in daylight intensity on the core circadian oscillator, a type of perturbation that has been rarely considered when assessing the robustness of circadian clocks.

  14. Effect of filler loading of characteristic natural rubber latex (NRL) film filled with nanocrystal cellulose (NCC) and dipersion agent polyvinylpyrrolidone (PVP)

    Science.gov (United States)

    Harahap, Hamidah; Lubis, Yuni Aldriani; Taslim, Iriany, Nasution, Halimatuddahliana; Agustini, Hamda Eka

    2018-04-01

    A study has been conducted on the effect of filler loading on NRL films filled with NCC from corn cob waste. This study reviews on the filler loading of NRL film characteristics. The process begins with the production of NCC filler and then proceed with the production NRL film which is processed by coagulant dipping method. NRL is filled with NCC and PVP as dispersion agent of 2, 4, 3, 8 grams (filler loading) and 1% PVP by weight. The production of NRL film started with pre-vulcanization process at 70 °C and followed by vulcanization process at 110 °C for 20 minutes. The results showed that higher filler loading improved the higher crosslink density and mechanical properties of NRL film.

  15. The impact of daylight saving time on electricity consumption: Evidence from southern Norway and Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Mirza, Faisal Mehmood, E-mail: faisal.mirza@umb.no [Department of Economics and Resource Management, Norwegian University of Life Sciences (UMB), P.O. Box 5003, 1432 As (Norway); Bergland, Olvar, E-mail: olvar.bergland@umb.no [Department of Economics and Resource Management, Norwegian University of Life Sciences (UMB), P.O. Box 5003, 1432 As (Norway)

    2011-06-15

    This paper examines the impact of daylight saving time (DST) on electricity consumption in southern Norway and Sweden. As DST was implemented in both the countries in 1980, we do not have a clear counterfactual in the form of a control period to identify the impact of DST directly with before and after or with and without analysis. This problem in the study is resolved by using 'equivalent day normalization technique' to identify the impact of DST. The difference-in-difference (DID) average treatment effects model suggests an annual reduction of at least 1.0 percent in electricity consumption for both Norway and Sweden due to DST. The average annual electricity consumption reduction corresponding to DST effects equals 519 and 882 GWh for southern Norway and Sweden, resulting in an annual financial saving of 16.1 million Euros and 30.1 million Euros, respectively. The distribution of treatment effects across different hours of the day indicates a small but significant reduction in electricity consumption during the morning and a steep decline during the evening hours in both countries. - Highlights: > We assess the impact of DST on electricity consumption in southern Norway and Sweden. > DST reduces electricity consumption by 1.3 percent in both countries. > The impact is smaller during the morning hours but larger during evening hours. > Respective annual financial savings equal Euro 16.1 and 30.1 million for Norway and Sweden. > Average annual electricity savings equal 519 and 882 GWh for two countries, respectively.

  16. The impact of daylight saving time on electricity consumption: Evidence from southern Norway and Sweden

    International Nuclear Information System (INIS)

    Mirza, Faisal Mehmood; Bergland, Olvar

    2011-01-01

    This paper examines the impact of daylight saving time (DST) on electricity consumption in southern Norway and Sweden. As DST was implemented in both the countries in 1980, we do not have a clear counterfactual in the form of a control period to identify the impact of DST directly with before and after or with and without analysis. This problem in the study is resolved by using 'equivalent day normalization technique' to identify the impact of DST. The difference-in-difference (DID) average treatment effects model suggests an annual reduction of at least 1.0 percent in electricity consumption for both Norway and Sweden due to DST. The average annual electricity consumption reduction corresponding to DST effects equals 519 and 882 GWh for southern Norway and Sweden, resulting in an annual financial saving of 16.1 million Euros and 30.1 million Euros, respectively. The distribution of treatment effects across different hours of the day indicates a small but significant reduction in electricity consumption during the morning and a steep decline during the evening hours in both countries. - Highlights: → We assess the impact of DST on electricity consumption in southern Norway and Sweden. → DST reduces electricity consumption by 1.3 percent in both countries. → The impact is smaller during the morning hours but larger during evening hours. → Respective annual financial savings equal Euro 16.1 and 30.1 million for Norway and Sweden. → Average annual electricity savings equal 519 and 882 GWh for two countries, respectively.

  17. Incidence of myocardial infarction with shifts to and from daylight savings time.

    Science.gov (United States)

    Jiddou, Monica R; Pica, Mark; Boura, Judy; Qu, Lihua; Franklin, Barry A

    2013-03-01

    Modulators of normal bodily functions such as the duration and quality of sleep might transiently influence cardiovascular risk. The transition to daylight savings time (DST) has been associated with a short-term increased incidence ratio (IR) of acute myocardial infarction (AMI). The present retrospective study examined the IR of AMIs that presented to our hospitals the week after DST and after the autumn switch to standard time, October 2006 to April 2012, with specific reference to the AMI type. Our study population (n = 935 patients; 59% men, 41% women) was obtained from the electronic medical records of the Royal Oak and Troy campuses of the Beaumont Hospitals in Michigan. Overall, the frequency of AMI was similar in the spring and autumn, 463 (49.5%) and 472 (50.5%), respectively. The IR for the first week after the spring shift was 1.17 (95% confidence interval 1.00 to 1.36). After the transition from DST in the autumn, the IR for the same period was lower, but not significantly different, 0.99 (95% confidence interval 0.85 to 1.16). Nevertheless, the greatest increase in AMI occurred on the first day (Sunday) after the spring shift to DST (1.71, 95% confidence interval 1.09 to 2.02; p <0.05). Also, a significantly greater incidence was found of non-ST-segment myocardial infarction after the transition to DST in the study group compared with that in the control group (p = 0.022). In conclusion, these data suggest that shifts to and from DST might transiently affect the incidence and type of acute cardiac events, albeit modestly. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Instrumentation and measurements of temperatures of a load of bricks in a tunnel kiln using natural gas; Instrumentacao e medicao de temperaturas em uma carga de tijolos no interior de um forno tunel a gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Jahn, T.G.; Lehmkuhl, W.A.; Hartke, Rafael Fernando; Dadam, A.P.; Nicolau, V.P. [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil)

    2004-07-01

    The analysis of the thermal efficiency of ceramics kilns, a big difficulty is the experimental determination of the temperature distribution inside the kiln load. The biggest challenge is the instrumentation, since the sensors should accompany the brick load through out the kiln, which may reach a length greater than 100 m, with their connection cables exposed to temperature greater than 300 deg C. These results are important to identify under what conditions are submitted internal layers of the brick load, to determine the best brick arrangements in cart load. This work permits a best understanding of firing cycles used in the tunnels kilns. The mathematical treatment and understanding of the data will permit to create experimental analysis tools, which should be useful in other problems. (author)

  19. Load Estimation from Modal Parameters

    DEFF Research Database (Denmark)

    Aenlle, Manuel López; Brincker, Rune; Fernández, Pelayo Fernández

    2007-01-01

    In Natural Input Modal Analysis the modal parameters are estimated just from the responses while the loading is not recorded. However, engineers are sometimes interested in knowing some features of the loading acting on a structure. In this paper, a procedure to determine the loading from a FRF m...

  20. Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight

    DEFF Research Database (Denmark)

    Nielsen, Martin Vraa; Svendsen, Svend; Bjerregaard Jensen, Lotte

    2011-01-01

    The façade design is and should be considered a central issue in the design of energy-efficient buildings. That is why dynamic façade components are increasingly used to adapt to both internal and external impacts, and to cope with a reduction in energy consumption and an increase in occupant...... them with various window heights and orientations. Their performance was evaluated on the basis of the building’s total energy demand, its energy demand for heating, cooling and lighting, and also its daylight factors. Simulation results comparing the three façade alternatives show potential...

  1. MAL Daylight Photodynamic Therapy for Actinic Keratosis: Clinical and Imaging Evaluation by 3D Camera.

    Science.gov (United States)

    Cantisani, Carmen; Paolino, Giovanni; Pellacani, Giovanni; Didona, Dario; Scarno, Marco; Faina, Valentina; Gobello, Tommaso; Calvieri, Stefano

    2016-07-11

    Non-melanoma skin cancer is the most common skin cancer with an incidence that varies widely worldwide. Among them, actinic keratosis (AK), considered by some authors as in situ squamous cell carcinoma (SCC), are the most common and reflect an abnormal multistep skin cell development due to the chronic ultraviolet (UV) light exposure. No ideal treatment exists, but the potential risk of their development in a more invasive form requires prompt treatment. As patients usually present with multiple AK on fields of actinic damage, there is a need for effective, safe, simple and short treatments which allow the treatment of large areas. To achieve this, daylight photodynamic therapy (DL-PDT) is an innovative treatment for multiple mild actinic keratosis, well tolerated by patients. Patients allocated to the PDT unit, affected by multiple mild-moderate and severe actinic keratosis on sun-exposed areas treated with DL-PDT, were clinically evaluated at baseline and every three months with an Antera 3D, Miravex(©) camera. Clinical and 3D images were performed at each clinical check almost every three months. In this retrospective study, 331 patients (56.7% male, 43.3% female) were treated with DL-PDT. We observed a full clearance in more than two-thirds of patients with one or two treatments. Different responses depend on the number of lesions and on their severity; for patients with 1-3 lesions and with grade I or II AK, a full clearance was reached in 85% of cases with a maximum of two treatments. DL-PDT in general improved skin tone and erased sun damage. Evaluating each Antera 3D images, hemoglobin concentration and pigmentation, a skin color and tone improvement in 310 patients was observed. DL-PDT appears as a promising, effective, simple, tolerable and practical treatment for actinic damage associated with AK, and even treatment of large areas can be with little or no pain. The 3D imaging allowed for quantifying in real time the aesthetic benefits of DL

  2. Fatal accidents following changes in daylight savings time: the American experience.

    Science.gov (United States)

    Varughese; Allen

    2001-01-01

    Objective: This study examines specific hypotheses that both sleep loss and behavioral changes occurring with the time shifts for Daylight Savings Time (DST) significantly effect the number of fatal traffic accidents in the United States of America.Background: It has been reported that there is a significant increase in the number of automobile accidents in the spring shift to DST due to the loss of 1 h of sleep. But the extra hour gained at night with the shift from DST in the fall has been variably reported to be associated with increases and decreases in the number of automobile accidents which may reflect either behavioral anticipation with an extended late night prior to the change or the benefit of extra sleep after the change.Methods: Data from 21 years of United States' fatal automobile accidents were gathered. The mean number of accidents on the days at the time of the shifts (Saturday, Sunday and Monday) was compared to the average of the corresponding mean number of accidents on the matching day of the weeks preceding and following the shift. This was repeated for each DST shift. The number of accidents for a particular shift was also correlated with the year of the accidents.Results: There was a significant increase in accidents for the Monday immediately following the spring shift to DST (t=1.92, P=0.034). There was also a significant increase in number of accidents on the Sunday of the fall shift from DST (P<0.002). No significant changes were observed for the other days. A significant negative correlation with the year was found between the number of accidents on the Saturdays and Sundays but not Mondays.Conclusions: The sleep deprivation on the Monday following shift to DST in the spring results in a small increase in fatal accidents. The behavioral adaptation anticipating the longer day on Sunday of the shift from DST in the fall leads to an increased number of accidents suggesting an increase in late night (early Sunday morning) driving when

  3. MAL Daylight Photodynamic Therapy for Actinic Keratosis: Clinical and Imaging Evaluation by 3D Camera

    Directory of Open Access Journals (Sweden)

    Carmen Cantisani

    2016-07-01

    Full Text Available Non-melanoma skin cancer is the most common skin cancer with an incidence that varies widely worldwide. Among them, actinic keratosis (AK, considered by some authors as in situ squamous cell carcinoma (SCC, are the most common and reflect an abnormal multistep skin cell development due to the chronic ultraviolet (UV light exposure. No ideal treatment exists, but the potential risk of their development in a more invasive form requires prompt treatment. As patients usually present with multiple AK on fields of actinic damage, there is a need for effective, safe, simple and short treatments which allow the treatment of large areas. To achieve this, daylight photodynamic therapy (DL-PDT is an innovative treatment for multiple mild actinic keratosis, well tolerated by patients. Patients allocated to the PDT unit, affected by multiple mild−moderate and severe actinic keratosis on sun-exposed areas treated with DL-PDT, were clinically evaluated at baseline and every three months with an Antera 3D, Miravex© camera. Clinical and 3D images were performed at each clinical check almost every three months. In this retrospective study, 331 patients (56.7% male, 43.3% female were treated with DL-PDT. We observed a full clearance in more than two-thirds of patients with one or two treatments. Different responses depend on the number of lesions and on their severity; for patients with 1–3 lesions and with grade I or II AK, a full clearance was reached in 85% of cases with a maximum of two treatments. DL-PDT in general improved skin tone and erased sun damage. Evaluating each Antera 3D images, hemoglobin concentration and pigmentation, a skin color and tone improvement in 310 patients was observed. DL-PDT appears as a promising, effective, simple, tolerable and practical treatment for actinic damage associated with AK, and even treatment of large areas can be with little or no pain. The 3D imaging allowed for quantifying in real time the aesthetic benefits

  4. T-cell tropism of simian T-cell leukaemia virus type 1 and cytokine profiles in relation to proviral load and immunological changes during chronic infection of naturally infected mandrills (Mandrillus sphinx).

    Science.gov (United States)

    Souquière, Sandrine; Mouinga-Ondeme, Augustin; Makuwa, Maria; Beggio, Paola; Radaelli, Antonia; De Giuli Morghen, Carlo; Mortreux, Franck; Kazanji, Mirdad

    2009-08-01

    Although a wide variety of non-human primates are susceptible to simian T-cell leukaemia virus type 1 (STLV-1), little is known about the virological or molecular determinants of natural STLV-1 infection. We determined STLV-1 virus tropism in vivo and its relation to the immune response by evaluating cytokine production and T-cell subsets in naturally infected and uninfected mandrills. With real-time PCR methods, we found that STLV-1 in mandrills infects both CD4(+) and CD8(+) T cells; however, proviral loads were significantly higher (P = 0.01) in CD4(+) than in CD8(+) cells (mean STLV-1 copies number per 100 cells (+/- SD) was 7.8 +/- 8 in CD4(+) T cells and 3.9 +/- 4.5 in CD8(+) T cells). After culture, STLV-1 provirus was detected in enriched CD4(+) but not in enriched CD8(+) T cells. After 6 months of culture, STLV-1-transformed cell lines expressing CD3(+), CD4(+) and HLADR(+) were established, and STLV-1 proteins and tax/rex mRNA were detected. In STLV-1 infected monkeys, there was a correlation between high proviral load and elevated levels of interleukin (IL)-2, IL-6, IL-10, interferon-gamma and tumour necrosis factor-alpha. The two monkeys with the highest STLV-1 proviral load had activated CD4(+)HLADR(+) and CD8(+)HLADR(+) T-cell subsets and a high percentage of CD25(+) in CD4(+) and CD8(+) T cells. Our study provides the first cellular, immunological and virological characterization of natural STLV-1 infection in mandrills and shows that they are an appropriate animal model for further physiopathological studies of the natural history of human T-cell leukaemia viruses.

  5. Parasite load induces progressive spleen architecture breakage and impairs cytokine mRNA expression in Leishmania infantum-naturally infected dogs.

    Science.gov (United States)

    Cavalcanti, Amanda S; Ribeiro-Alves, Marcelo; Pereira, Luiza de O R; Mestre, Gustavo Leandro; Ferreira, Anna Beatriz Robottom; Morgado, Fernanda N; Boité, Mariana C; Cupolillo, Elisa; Moraes, Milton O; Porrozzi, Renato

    2015-01-01

    Canine Visceral Leishmaniasis (CVL) shares many aspects with the human disease and dogs are considered the main urban reservoir of L. infantum in zoonotic VL. Infected dogs develop progressive disease with a large clinical spectrum. A complex balance between the parasite and the genetic/immunological background of the host are decisive for infection evolution and clinical outcome. This study comprised 92 Leishmania infected mongrel dogs of various ages from Mato Grosso, Brazil. Spleen samples were collected for determining parasite load, humoral response, cytokine mRNA expression and histopathology alterations. By real-time PCR for the ssrRNA Leishmania gene, two groups were defined; a low (lowP, n = 46) and a high parasite load groups (highP, n = 42). When comparing these groups, results show variable individual humoral immune response with higher specific IgG production in infected animals but with a notable difference in CVL rapid test optical densities (DPP) between highP and lowP groups. Splenic architecture disruption was characterized by disorganization of white pulp, more evident in animals with high parasitism. All cytokine transcripts in spleen were less expressed in highP than lowP groups with a large heterogeneous variation in response. Individual correlation analysis between cytokine expression and parasite load revealed a negative correlation for both pro-inflammatory cytokines: IFNγ, IL-12, IL-6; and anti-inflammatory cytokines: IL-10 and TGFβ. TNF showed the best negative correlation (r2 = 0.231; pdogs with high parasite load associated with a structural modification in the splenic lymphoid micro-architecture. We also discuss the possible mechanism responsible for the uncontrolled parasite growth and clinical outcome.

  6. The daylight saving time in Mexico; El cambio de horario durante la epoca del verano en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The daylight saving time in Mexico for energy saving is analyzed; such a change is made forwarding the clocks one hour in all Mexico the first Sunday of April and backing them an hour the last Sunday of October. Mention is made the reasons why Mexico adopted this measure, the social-economic impact that brings along and the benefits of this daylight saving time. The case of countries that also apply this measure is analyzed. It is expected that this measure attains benefits for the society either collectively or individually through the ecology and the economy. [Espanol] Se analiza el cambio de horario en la epoca de verano en Mexico para ahorrar energia; dicho cambio se realiza al adelantar una hora al reloj en todo el territorio de Mexico el primer domingo de abril y retrazarlo una hora el ultimo domingo de octubre. Se mencionan las razones por las cuales Mexico adopto esta medida, el impacto socio-economico que traera consigo y los beneficios del cambio de horario. Se aborda la situacion de los paises que tambien aplican esta medida. Se espera que esta medida logre beneficios para la sociedad, ya sea en modo colectivo o individual, para la ecologia y para la economia.

  7. Continuous daylight in the high-Arctic summer supports high plankton respiration rates compared to those supported in the dark

    KAUST Repository

    Mesa, Elena

    2017-04-21

    Plankton respiration rate is a major component of global CO2 production and is forecasted to increase rapidly in the Arctic with warming. Yet, existing assessments in the Arctic evaluated plankton respiration in the dark. Evidence that plankton respiration may be stimulated in the light is particularly relevant for the high Arctic where plankton communities experience continuous daylight in spring and summer. Here we demonstrate that plankton community respiration evaluated under the continuous daylight conditions present in situ, tends to be higher than that evaluated in the dark. The ratio between community respiration measured in the light (Rlight) and in the dark (Rdark) increased as the 2/3 power of Rlight so that the Rlight:Rdark ratio increased from an average value of 1.37 at the median Rlight measured here (3.62 µmol O2 L-1 d-1) to an average value of 17.56 at the highest Rlight measured here (15.8 µmol O2 L-1 d-1). The role of respiratory processes as a source of CO2 in the Arctic has, therefore, been underestimated and is far more important than previously believed, particularly in the late spring, with 24 h photoperiods, when community respiration rates are highest.

  8. The daylight saving time in Mexico; El cambio de horario durante la epoca del verano en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Covarrubias Ramos, Rogelio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The daylight saving time in Mexico for energy saving is analyzed; such a change is made forwarding the clocks one hour in all Mexico the first Sunday of April and backing them an hour the last Sunday of October. Mention is made the reasons why Mexico adopted this measure, the social-economic impact that brings along and the benefits of this daylight saving time. The case of countries that also apply this measure is analyzed. It is expected that this measure attains benefits for the society either collectively or individually through the ecology and the economy. [Espanol] Se analiza el cambio de horario en la epoca de verano en Mexico para ahorrar energia; dicho cambio se realiza al adelantar una hora al reloj en todo el territorio de Mexico el primer domingo de abril y retrazarlo una hora el ultimo domingo de octubre. Se mencionan las razones por las cuales Mexico adopto esta medida, el impacto socio-economico que traera consigo y los beneficios del cambio de horario. Se aborda la situacion de los paises que tambien aplican esta medida. Se espera que esta medida logre beneficios para la sociedad, ya sea en modo colectivo o individual, para la ecologia y para la economia.

  9. Spanish-Portuguese consensus statement on use of daylight-mediated photodynamic therapy with methyl aminolevulinate in the treatment of actinic keratosis.

    Science.gov (United States)

    Gilaberte, Y; Aguilar, M; Almagro, M; Correia, O; Guillén, C; Harto, A; Pérez-García, B; Pérez-Pérez, L; Redondo, P; Sánchez-Carpintero, I; Serra-Guillén, C; Valladares, L M

    2015-10-01

    Daylight-mediated photodynamic therapy (PDT) is a new type of PDT that is as effective as conventional PDT in grade 1 and 2 actinic keratosis but with fewer adverse effects, resulting in greater efficiency. The climatic conditions in the Iberian Peninsula require an appropriately adapted consensus protocol. We describe a protocol for the treatment of grade 1 and 2 actinic keratosis with daylight-mediated PDT and methyl aminolevulinate (MAL) adapted to the epidemiological and clinical characteristics of Spanish and Portuguese patients and the climatic conditions of both countries. Twelve dermatologists from different parts of Spain and Portugal with experience in the treatment of actinic keratosis with PDT convened to draft a consensus statement for daylight-mediated PDT with MAL in these countries. Based on a literature review and their own clinical experience, the group developed a recommended protocol. According to the recommendations adopted, patients with multiple grade 1 and 2 lesions, particularly those at risk of developing cancer, are candidates for this type of therapy. Daylight-mediated PDT can be administered throughout the year, although it is not indicated at temperatures below 10°C or at excessively high temperatures. Likewise, therapy should not be administered when it is raining, snowing, or foggy. The procedure is simple, requiring application of a sunscreen with a protection factor of at least 30 based exclusively on organic filters, appropriate preparation of the lesions, application of MAL without occlusion, and activation in daylight for 2hours. This consensus statement represents a practical and detailed guideline to achieve maximum effectiveness of daylight-mediated PDT with MAL in Spain and Portugal with minimal adverse effects. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  10. Load forecasting

    International Nuclear Information System (INIS)

    Mak, H.

    1995-01-01

    Slides used in a presentation at The Power of Change Conference in Vancouver, BC in April 1995 about the changing needs for load forecasting were presented. Technological innovations and population increase were said to be the prime driving forces behind the changing needs in load forecasting. Structural changes, market place changes, electricity supply planning changes, and changes in planning objectives were other factors discussed. It was concluded that load forecasting was a form of information gathering, that provided important market intelligence

  11. The effect of dynamic solar shading on energy, daylighting and thermal comfort in a nearly zero-energy loft room in Rome and Copenhagen

    DEFF Research Database (Denmark)

    Skarning, Gunnlaug Cecilie Jensen; Hviid, Christian Anker; Svendsen, Svend

    2017-01-01

    alternatives in buildings with very low space-heating demand, this study mapped and compared energy, daylighting and thermal comfort for various combinations of window size and glazing properties, with and without dynamic shading. The study considered a loft room with sloped roof windows and moderate venting...... as defined by the Adaptive Thermal Comfort (ATC) model....... options in nearly zero-energy homes in Rome and Copenhagen. The more flexible solution space with dynamic shading made it possible to either reduce the time with operative temperatures exceeding the comfort limit by 40–50 h or increase daylighting by 750–1000 h more than could be achieved without shading...

  12. Balancing the daylighting and energy performance of solar screens in residential desert buildings: Examination of screen axial rotation and opening aspect ratio

    KAUST Repository

    Sabry, Hanan

    2014-05-01

    Solar screens are typically used to control solar access into building spaces. They proved their usefulness in improving the daylighting and energy performance of buildings in the hot arid desert environments which are endowed with abundance of clear skies.The daylighting and energy performance of solar screens is affected by many parameters. These include screen perforation, depth, reflectivity and color, aspect ratio of openings, shape, tilt angle and rotation. Changing some of these parameters can improve the daylighting performance drastically. However, this can result in increased energy consumption. A balanced solution must be sought, where acceptable daylighting performance would be achieved at minimum energy consumption.This paper aims at defining solar screen designs that achieve visual comfort and at the same time minimum energy consumption in residential desert settings. The study focused on the effect of changing the solar screen axial rotation and the aspect ratio of its openings under the desert clear-sky. The individual and combined effects of changing these parameters were studied.Results of this study demonstrated that a non-rotated solar screen that has wide horizontal openings (aspect ratio of 18:1) proved to be successful in the north and south orientations. Its performance in the east/west orientations was also superior. In contrast, the screen that was rotated along its vertical axis while having small size openings (aspect ratio of 1:1) proved to be more successful in the east/west orientations. Its performance in the north orientation was also good. These solutions enhanced daylighting performance, while maintaining the energy consumption at a minimum.Moreover, it was observed that combining two screen parameters which proved useful in previous studies on daylighting or thermal performance does not add up to better solutions. The combined solutions that were tested in this study did not prove successful in satisfying daylighting and thermal

  13. Continuous activation of PpIX by daylight is as effective as and less painful than conventional photodynamic therapy for actinic keratoses; a randomized, controlled, single-blinded study

    DEFF Research Database (Denmark)

    Wiegell, S.R.; Hædersdal, Merete; Philipsen, P.A.

    2008-01-01

    of the face and scalp were treated with MAL-PDT in two symmetrical areas. One area was illuminated by red LED light (37 J cm(-2)) after 3-h incubation with MAL under occlusive dressing. The other area was treated with daylight for 2.5 h after the MAL cream had been under occlusion for half an hour. Results We...... found no significant difference in the treatment effect between the two treatments (P = 0.13), with a reduction of AK lesions of 79% in the daylight area compared with 71% in the LED area. Treatment response in the daylight area did not depend on the intensity of the daylight. Illumination with LED...... of porphyrins during its formation. Objectives The objective of this randomized controlled study was to compare response rates and adverse effects after methyl aminolevulinate (MAL)-PDT using conventional red light-emitting diode (LED) light vs. daylight. Patients/methods Twenty-nine patients with AK...

  14. Effects of accelerated artificial daylight aging on bending strength and bonding of glass fibers in fiber-embedded maxillofacial silicone prostheses.

    Science.gov (United States)

    Hatamleh, Muhanad M; Watts, David C

    2010-07-01

    The purpose of this study was to test the effect of different periods of accelerated artificial daylight aging on bond strength of glass fiber bundles embedded into maxillofacial silicone elastomer and on bending strength of the glass fiber bundles. Forty specimens were fabricated by embedding resin-impregnated fiber bundles (1.5-mm diameter, 20-mm long) into maxillofacial silicone elastomer. Specimens were randomly allocated into four groups, and each group was subjected to different periods of accelerated daylight aging as follows (in hours); 0, 200, 400, and 600. The aging cycle included continuous exposure to quartz-filtered visible daylight (irradiance 760 W/m(2)) under an alternating weathering cycle (wet for 18 minutes, dry for 102 minutes). Pull-out tests were performed to evaluate bond strength between fiber bundles and silicone using a universal testing machine at 1 mm/min crosshead speed. Also a three-point bending test was performed to evaluate bending strength of the fiber bundles. One-way ANOVA and Bonferroni post hoc tests were carried out to detect statistical significance (p aging only. After 200 hours of exposure to artificial daylight and moisture conditions, bond strength between glass fibers and heat-cured silicones is optimal, and the bending strength of the glass fiber bundles is enhanced.

  15. Impact of windows and daylight exposure on overall health and sleep quality of office workers: a case-control pilot study.

    Science.gov (United States)

    Boubekri, Mohamed; Cheung, Ivy N; Reid, Kathryn J; Wang, Chia-Hui; Zee, Phyllis C

    2014-06-15

    This research examined the impact of daylight exposure on the health of office workers from the perspective of subjective well-being and sleep quality as well as actigraphy measures of light exposure, activity, and sleep-wake patterns. Participants (N = 49) included 27 workers working in windowless environments and 22 comparable workers in workplaces with significantly more daylight. Windowless environment is defined as one without any windows or one where workstations were far away from windows and without any exposure to daylight. Well-being of the office workers was measured by Short Form-36 (SF-36), while sleep quality was measured by Pittsburgh Sleep Quality Index (PSQI). In addition, a subset of participants (N = 21; 10 workers in windowless environments and 11 workers in workplaces with windows) had actigraphy recordings to measure light exposure, activity, and sleep-wake patterns. Workers in windowless environments reported poorer scores than their counterparts on two SF-36 dimensions--role limitation due to physical problems and vitality--as well as poorer overall sleep quality from the global PSQI score and the sleep disturbances component of the PSQI. Compared to the group without windows, workers with windows at the workplace had more light exposure during the workweek, a trend toward more physical activity, and longer sleep duration as measured by actigraphy. We suggest that architectural design of office environments should place more emphasis on sufficient daylight exposure of the workers in order to promote office workers' health and well-being.

  16. Continuous ultra-low-intensity artificial daylight is not as effective as red LED light in photodynamic therapy of multiple actinic keratoses

    DEFF Research Database (Denmark)

    Wiegell, Stine Regin; Heydenreich, Jakob; Fabricius, Susanne

    2011-01-01

    Daylight-mediated photodynamic therapy (PDT) is a simple and tolerable treatment of nonmelanoma skin cancer. It is of interest which light intensity is sufficient to prevent accumulation of protoporphyrin IX (PpIX) and effectively treat actinic keratoses (AKs). We compared the efficacy of PDT...

  17. Daylight-saving time: Consumption and demand saving and pollutants emission reduction; El cambio de horario de verano: Ahorros en consumo y demanda, y reduccion de contaminantes

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Gaudencio; Diaz, Rodrigo; Fiscal, Raul; Alquicira, Claudia; Martinez, Serafin; Maqueda, Martin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    This paper presents some of the saving obtained in demand and in fuels with the daylight-saving time, as well as the main aspects considered to make an evaluation of it. [Espanol] Se presentan los ahorros obtenidos en consumo, demanda y combustibles con el cambio de horario de verano, asi como los principales aspectos considerados para efectuar la evaluacion de los mismos.

  18. Combination of ablative fractional laser and daylight-mediated photodynamic therapy for actinic keratosis in organ transplant recipients – a randomized controlled trial

    DEFF Research Database (Denmark)

    Togsverd-Bo, Katrine; Lei, Ulrikke; Erlendsson, A M

    2015-01-01

    BACKGROUND: Topical photodynamic therapy (PDT) for actinic keratoses (AK) is hampered by pain during illumination and inferior efficacy in organ-transplant recipients (OTR). OBJECTIVES: We assessed ablative fractional laser (AFL)-assisted daylight photodynamic therapy (PDT) (AFL-dPDT) compared...

  19. Photodynamic therapy of actinic keratoses with 8% and 16% methyl aminolaevulinate and home-based daylight exposure: a double-blinded randomized clinical trial

    DEFF Research Database (Denmark)

    Wiegell, S.R.; Haedersdal, M.; Eriksen, P.

    2009-01-01

    Background Photodynamic therapy (PDT) is an effective but time-consuming and often painful treatment for actinic keratosis (AK). Home-based daylight-PDT has the potential to facilitate treatment procedure and to reduce associated pain due to continuous activation of small amounts of porphyrins...

  20. Daylight photodynamic therapy with methyl aminolevulinate cream as a convenient, similarly effective, nearly painless alternative to conventional photodynamic therapy in actinic keratosis treatment

    DEFF Research Database (Denmark)

    Rubel, D M; Spelman, L; Murrell, D F

    2014-01-01

    BACKGROUND: Daylight photodynamic therapy (DL-PDT) of actinic keratosis (AK) has shown preliminary efficacy and safety results comparable to conventional photodynamic therapy (c-PDT), using methyl aminolevulinate (MAL) cream. OBJECTIVES: To demonstrate the efficacy and safety of DL-PDT vs. c...

  1. A statistical analysis of the energy policy act of 2005, its changes to the daylight saving program, and impact on residential energy consumption

    Science.gov (United States)

    Murray, Patrick L.

    Government programs designed to decrease resource consumption, improve productivity and capitalize on extended daylight hours in the summer have been developed and implemented throughout the world for nearly three hundred years. In 2005, The United States government adopted an extended daylight savings program that increases the number of weeks where the country observes Daylight Saving Time (DST) from 31 to 35 weeks. The program took effect in March 2007. Arguments in support of DST programs highlight the portion of electricity consumption attributed to residential lighting in the evening hours. Adjusting clocks forward by one hour in summer months is believed to reduce electricity consumption due to lighting and therefore significantly reduce residential energy consumption during the period of DST. This paper evaluates the efficacy of the changes to DST resulting from the Energy Policy Act of 2005. The study focuses on changes to household electricity consumption during the extended four weeks of DST. Arizona, one of two states that continue to opt out of DST serves as the study's control for a comparison with neighboring states, Colorado, Nebraska, Nevada, New Mexico, Oklahoma, Texas and Utah. Results from the regression analysis of a Difference in Difference model indicate that contrary to evaluations by Congress and the Department of Energy, the four week period of Extended Daylight Saving Time does not produce a significant decrease in per capita electricity consumption in Southwestern states.

  2. Daylight-saving time: Consumption and demand saving and pollutants emission reduction; El cambio de horario de verano: Ahorros en consumo y demanda, y reduccion de contaminantes

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Gaudencio; Diaz, Rodrigo; Fiscal, Raul; Alquicira, Claudia; Martinez, Serafin; Maqueda, Martin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    This paper presents some of the saving obtained in demand and in fuels with the daylight-saving time, as well as the main aspects considered to make an evaluation of it. [Espanol] Se presentan los ahorros obtenidos en consumo, demanda y combustibles con el cambio de horario de verano, asi como los principales aspectos considerados para efectuar la evaluacion de los mismos.

  3. Physicochemical characterization by AFM, FT-IR and DSC and biological assays of a promising antileishmania delivery system loaded with a natural Brazilian product.

    Science.gov (United States)

    Marquele-Oliveira, Franciane; Torres, Elina Cassia; Barud, Hernane da Silva; Zoccal, Karina Furlani; Faccioli, Lúcia Helena; Hori, Juliana I; Berretta, Andresa Aparecida

    2016-05-10

    The control and treatment of Leishmaniasis, a neglected and infectious disease affecting approximately 12 million people worldwide, are challenging. Leishmania parasites multiply intracellularly within macrophages located in deep skin and in visceral tissues, and the currently employed treatments for this disease are subject to significant drawbacks, such as resistance and toxicity. Thus, the search for new Leishmaniasis treatments is compulsory, and Ocotea duckei Vattimo, a plant-derived product from the biodiverse Brazilian flora, may be a promising new treatment for this disease. In this regard, the aim of this work was to develop and characterize a delivery system based on solid lipid nanoparticles (SLN) that contain the liposoluble lignan fraction (LF) of Ocotea duckei Vattimo, which targets the Leishmania phagolysosome of infected macrophages. LF-loaded SLNs were obtained via the hot microemulsion method, and their physical and chemical properties were comprehensively assessed using PCS, AFM, SEM, FT-IR, DSC, HPLC, kinetic drug release studies, and biological assays. The size of the developed delivery system was 218.85±14.2 nm, its zeta potential was -30 mV and its entrapment efficiency (EE%) was high (the EEs% of YAN [yangambin] and EPI-YAN [epi-yangambin] markers were 94.21±0.40% and 94.20±0.00%, respectively). Microscopy, FT-IR and DSC assays confirmed that the delivery system was nanosized and indicated a core-shell encapsulation model, which corroborated the measured kinetics of drug release. The total in vitro release rates of YAN and EPI-YAN in buffer (with sink conditions attained) were 29.6±8.3% and 34.3±8.9%, respectively, via diffusion through the cellulose acetate membrane of the SLN over a period of 4 h. After 24 h, the release rates of both markers reached approximately 45%, suggesting a sustained pattern of release. Mathematical modeling indicated that both markers, YAN and EPI-YAN, followed matrix diffusion-based release kinetics (Higuchi

  4. Parametric analysis of parameters for electrical-load forecasting using artificial neural networks

    Science.gov (United States)

    Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael

    1997-04-01

    Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.

  5. Multiple assessment of the soil cover in the area of natural monuments Tra-Tau and Yurak-Tau monadnocks under conditions of technogenic loads

    Science.gov (United States)

    Gabbasova, I. M.; Suleymanov, R. R.; Khabirov, I. K.; Komissarov, M. A.; Garipov, T. T.; Sidorova, L. V.; Nazyrova, F. I.

    2014-02-01

    The soil cover of Tra-Tau and Yurak-Tau shikhans (monadnocks) has been examined. Leached and typical medium-deep chernozems are developed on colluvial fans on the footslopes and on the lower parts of slopes, whereas typical calcareous thin slightly and moderately gravelly chernozems are developed on the upper and medium parts of slopes. The leached and typical chernozems of the footslopes correspond to zonal soils of the adjacent plain areas, though they have some specific features related to the local topographic conditions. These soils are somewhat thinner than plain chernozems and are characterized by the perfect granular water-stable structure, the high content of humus of the humate type, the high content of exchangeable cations, strong acid-base buffering, and high enzymatic activity. These features predetermine their high tolerance towards technogenic impacts. The concentrations of highly hazardous substances of the first toxicity class (mercury, arsenic, lead, and cadmium) and of moderately hazardous substances of the second toxicity class (copper, zinc, and nickel), as well as the concentrations of low-hazardous elements (manganese and iron) in these soils do not exceed provisional maximum permissible concentrations of these substances in soils irrespectively of the slope aspect. No changes in the physicochemical and biological properties of the soils under the impact of technogenic loads from Sterlitamak industrial center have been identified.

  6. Beam loading

    OpenAIRE

    Boussard, Daniel

    1987-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superco...

  7. NATURAL LIGHTING OF DEEP ARCHITECTURAL SPACE: THE PERCEPTION OF NEW ZEALAND ARCHITECTS

    Directory of Open Access Journals (Sweden)

    Richard Barrett

    2008-07-01

    Full Text Available The paper considers aspects of a survey carried out amongst a group of registered New Zealand architects in order to establish their knowledge and experience in using core-daylighting systems and methods (Barrett, 2003. Core-daylighting comprises systems and methods for bringing natural light into deep architectural space where conventional methods (such as windows and skylights cannot readily be used. Examples of these methods are: atria (Matusiak, 1998, sun tracking heliostats, sun and light pipes, light scoops, Fresnel lenses, anidolic zenithal systems, prismatic daylight systems, light shelves, tapping mirrors, light reflectors and louvres (Littlefair, 1991, 1996 & 2000, lightwells, internal courts (Lam, 1986, fibre optic cable (Kay,1999, and other systems for light re-direction. The survey was carried out using a questionnaire as described below (Survey Methods. The findings were analysed, resulting in a clear indication that the respondents were not especially experienced or knowledgeable, and a majority felt this to be an area of their skill base in need of development. Whilst the survey was strictly intended to gather quantitative material, respondents were invited to comment freely as they progressed through to completion of the questionnaire. This paper draws on this qualitative data as an insight into several areas, including the attitudes of respondents towards their clients when making decisions about designing buildings for natural daylighting.

  8. Laboratory and pilot-scale field experiments for application of iron oxide nanoparticle-loaded chitosan composites to phosphate removal from natural water.

    Science.gov (United States)

    Kim, Jae-Hyun; Kim, Song-Bae; Lee, Sang-Hyup; Choi, Jae-Woo

    2018-03-01

    The aim of this study was to apply iron oxide nanoparticle-chitosan (ION-chitosan) composites to phosphate removal from natural water collected from the Seoho Stream in Suwon, Republic of Korea. Laboratory batch experiments showed that phosphate removal by the ION-chitosan composites was not sensitive to pH changes between pH values of 5.0 and 9.0. During six cycles of adsorption-desorption, the composites could be successfully regenerated with 5 mM NaOH solution and reused for phosphate removal. Laboratory fixed-bed column experiments (column height = 10 and 20 cm, inner diameter = 2.5 cm, flow rate = 8.18 and 16.36 mL/min) demonstrated that the composites could be successfully applied for phosphate removal under dynamic flow conditions. A pilot-scale field experiment was performed in a pilot plant, which was mainly composed of chemical reactor/dissolved air flotation and an adsorption tower, built nearby the Seoho Stream. The natural water was pumped from the Seoho Stream into the pilot plant, passed through the chemical reactor/dissolved air flotation process, and then introduced into the adsorption tower (height = 100 cm, inner diameter = 45 cm, flow rate = 7.05 ± 0.18 L/min) for phosphate removal via the composites (composite volume = 80 L, composite weight = 85.74 kg). During monitoring of the adsorption tower (33 days), the influent total phosphorus (T-P) concentration was in the range of 0.020-0.046 mgP/L, whereas the effluent T-P concentration was in the range of 0.010-0.028 mgP/L. The percent removal of T-P in the adsorption tower was 52.3% with a phosphate removal capacity of 0.059 mgP/g.

  9. Beam loading

    CERN Document Server

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  10. Beam loading

    International Nuclear Information System (INIS)

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed. (author)

  11. Load sensor

    NARCIS (Netherlands)

    Van den Ende, D.; Almeida, P.M.R.; Dingemans, T.J.; Van der Zwaag, S.

    2007-01-01

    The invention relates to a load sensor comprising a polymer matrix and a piezo-ceramic material such as PZT, em not bedded in the polymer matrix, which together form a compos not ite, wherein the polymer matrix is a liquid crystalline resin, and wherein the piezo-ceramic material is a PZT powder

  12. Carbohydrate Loading.

    Science.gov (United States)

    Csernus, Marilyn

    Carbohydrate loading is a frequently used technique to improve performance by altering an athlete's diet. The objective is to increase glycogen stored in muscles for use in prolonged strenuous exercise. For two to three days, the athlete consumes a diet that is low in carbohydrates and high in fat and protein while continuing to exercise and…

  13. A study on the performance enhancement of low-temperature solar applications : Daylighting and Adsorption Desalination System

    International Nuclear Information System (INIS)

    Kim, Yeong Min

    2011-02-01

    Thermal applications of solar energy are categorized by low, medium and high temperature. The present study has explored two major applications of solar energy widely researched and practiced these days. Of these, one deals with the utilization of solar energy for lighting in buildings, which is responsible for a great portion of electricity consumption, especially, for office and public buildings. Rapid improvements in lighting technology harnessing solar energy (daylight) have greatly contributed to radically reduce its consumption levels - and thereby reduce CO 2 emissions and cost. The other case considered here for solar utilization is so-called solar desalination using adsorbents (silica gels). This technology utilizes a silica gel adsorbent (desiccant) as a medium between an evaporator and a condenser to reject and facilitate latent heat of vaporization. Vapour is adsorbed and desorbed between evaporation and condensation phases. 1. Daylighting simulation A lighting upgrade is an obvious step toward improving a building's energy consumption, which could be easily assessed by using computer simulations. The present study has carried out a series of computer simulations for a lightless space as well as an actual classroom (in Jeju National University) when sun pipe systems are installed. They were first modeled by ECOTECT before RADIANCE was called in to conduct lighting analysis. Simulations were performed for equinoxes and solstices when the sun is at its highest altitude, i.e. at noon (12 PM). A lightless space and classroom of the same dimensions revealed the effectiveness of sun pipe systems to improve indoor lighting conditions throughout the year. 2. Development of adsorption desalination system utilizing silica-gel Some major components of an adsorption desalination system were designed and fabricated to assess its desalination efficiency when packs of silica-gel were used at different operating conditions. The amount of fresh water yield was studied

  14. A study on the performance enhancement of low-temperature solar applications : Daylighting and Adsorption Desalination System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeong Min

    2011-02-15

    Thermal applications of solar energy are categorized by low, medium and high temperature. The present study has explored two major applications of solar energy widely researched and practiced these days. Of these, one deals with the utilization of solar energy for lighting in buildings, which is responsible for a great portion of electricity consumption, especially, for office and public buildings. Rapid improvements in lighting technology harnessing solar energy (daylight) have greatly contributed to radically reduce its consumption levels - and thereby reduce CO{sub 2} emissions and cost. The other case considered here for solar utilization is so-called solar desalination using adsorbents (silica gels). This technology utilizes a silica gel adsorbent (desiccant) as a medium between an evaporator and a condenser to reject and facilitate latent heat of vaporization. Vapour is adsorbed and desorbed between evaporation and condensation phases. 1. Daylighting simulation A lighting upgrade is an obvious step toward improving a building's energy consumption, which could be easily assessed by using computer simulations. The present study has carried out a series of computer simulations for a lightless space as well as an actual classroom (in Jeju National University) when sun pipe systems are installed. They were first modeled by ECOTECT before RADIANCE was called in to conduct lighting analysis. Simulations were performed for equinoxes and solstices when the sun is at its highest altitude, i.e. at noon (12 PM). A lightless space and classroom of the same dimensions revealed the effectiveness of sun pipe systems to improve indoor lighting conditions throughout the year. 2. Development of adsorption desalination system utilizing silica-gel Some major components of an adsorption desalination system were designed and fabricated to assess its desalination efficiency when packs of silica-gel were used at different operating conditions. The amount of fresh water yield was

  15. A modified model for estimation of daylight factor for skylight integrated with dome roof structure of mud-house in New Delhi (India)

    Energy Technology Data Exchange (ETDEWEB)

    Chel, Arvind; Tiwari, G.N.; Singh, H.N. [Centre for Energy Studies (CES), Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016 (India)

    2010-10-15

    The daylight factor model given by Charted Institute of Building Services Engineers (CIBSE) was modified in this paper to incorporate time variations with respect to zenith angle ({theta}{sub z}) and vertical height (h) of working surface above ground surface which was normalized with central height (H) of skylight dome. The modified model contains constant exponents which are determined using linear regression analysis based on hourly experimental data of inside and outside illuminance for each month of the year 2007-2008. The prediction of modified model is found in good agreement with experimental observed inside illuminance data on the basis of values of root mean square percentage error (e) and correlation coefficient (r). The annual average daylight factor values for big and small dome skylight rooms are determined as 2.3% and 4.4% respectively. The energy saving potential of skylight rooms for selected climatic locations in India is also presented in this paper. (author)

  16. Load sensor

    OpenAIRE

    Van den Ende, D.; Almeida, P.M.R.; Dingemans, T.J.; Van der Zwaag, S.

    2007-01-01

    The invention relates to a load sensor comprising a polymer matrix and a piezo-ceramic material such as PZT, em not bedded in the polymer matrix, which together form a compos not ite, wherein the polymer matrix is a liquid crystalline resin, and wherein the piezo-ceramic material is a PZT powder forming 30-60% by volume of the composite, and wherein the PZT powder forms 40-50% by volume of the composite.

  17. Workshop - Solar cells and daylight. Solar cell house. House building with integrated solar cell systems; Workshop - Solceller og dagslys. Solcellehus. Boligbyggeri med integrerede solcelleanlaeg

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Mio; Hansen, Ellen Kathrine

    2005-04-15

    The workshop 'Solar cells and daylight' at Aarhus School of Architecture aimed at studying and developing architectural potentials of integrating solar cell systems in building components for future house building. The aim of the process was to stress that technical conditions such as energy technological component design might work as central points of support in the future shaping and organisation of qualitative and functional design of houses. (BA)

  18. Daylight methyl-aminolevulinate photodynamic therapy versus ingenol mebutate for the treatment of actinic keratoses: an intraindividual comparative analysis.

    Science.gov (United States)

    Genovese, Giovanni; Fai, Dario; Fai, Carlotta; Mavilia, Luciano; Mercuri, Santo R

    2016-05-01

    Daylight-photodynamic therapy (D-PDT) and ingenol mebutate (IM) are novel therapies directed to actinic keratoses (AK). The purpose of our study was to compare effectiveness, tolerability, cosmetic outcome and patient preference of D-PDT versus IM in the treatment of grade I and II AK. Twenty-seven patients with AK on the face or scalp were enrolled. Each patient received, in a 25 cm(2) target area, D-PDT on right side and IM on left side. Overall 323 AK were treated. Both target areas achieved complete response in 40.47% of the cases and average AK clearance rate was similar for D-PDT and IM (p=0.74). In D-PDT areas mean grade II AK clearance rate was lower compared with that of grade I AK (p=0.015). In IM areas grade I and II AK average clearance rates were similar (p=0.28). At week 1 and month 1, mean local skin responses (LSR) score were higher in areas treated with IM. IM areas showed more severe pain and cosmetic sequelae. D-PDT had similar effectiveness to IM, even if IM demonstrated higher grade II AK clearance rate. Tolerability profile was superior for D-PDT in terms of LSR and pain. D-PDT was more cosmetically acceptable. Patients preferred D-PDT to IM in most cases. © 2016 Wiley Periodicals, Inc.

  19. Rapid microwave-assisted nonaqueous synthesis and growth mechanism of AgCl/Ag, and its daylight-driven plasmonic photocatalysis.

    Science.gov (United States)

    Jiang, Jing; Zhang, Lizhi

    2011-03-21

    We report on a rapid microwave-assisted nonaqueous synthesis and the growth mechanism of AgCl/Ag with controlled size and shape. By rationally varying the reaction temperature and the microwave irradiation time, we achieved the transformation of nanocubes to rounded triangular pyramids by a combined process of "oriented attachment" and Ostwald ripening. The surface plasmon resonance (SPR) properties of the as-prepared AgCl/Ag have been found to be somewhat dependent on the size, morphology, and composition. The as-prepared AgCl/Ag exhibits high photocatalytic activity and good reusability for decomposing organic pollutants (such as methyl orange (MO), rhodamine B (RhB), and pentachlorophenol (PCP)) under indoor artificial daylight illumination (ca. 1 mW cm(-2)). The AgCl/Ag has also been found to display a superior ability to harvest diffuse indoor daylight (ca. 5 mW cm(-2)), and could complete the degradation of 10 mg  L(-1) MO within 15 min. Experiments involving the trapping of active species have shown that the photocatalytic degradation of organic pollutants in the AgCl/Ag system may proceed through direct hole transfer. This study has revealed that plasmonic daylight photocatalysis may open a new frontier for indoor pollutant control around the clock under fluorescent lamp illumination. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Assessment of building facade performance in terms of daylighting and the associated energy consumption in architectural spaces: Vertical and horizontal shading devices for southern exposure facades

    Energy Technology Data Exchange (ETDEWEB)

    Alzoubi, Hussain H.; Al-Zoubi, Amneh H. [Department of Architecture, Jordan University of Science and Technology, Irbid 22110 (Jordan)

    2010-08-15

    This paper examines the effect of vertical and horizontal shading devices on the quality of daylight in buildings and the associated energy saving. Excessive daylight in architectural spaces contributes negatively to the energy consumption in buildings. Blinds and shading devices are good solutions to attenuate the surplus amount of daylight in spaces. Accordingly, this study evaluates the effect of shading devices on the amount of light flux and the associated solar energy in buildings. It estimates the energy consumption attributed to lighting spaces for three common positions of shading devices. Computer simulation strategy was undertaken to correlate the illuminance level in spaces with room geometry and architectural shading elements. The Holophane model for lighting calculations was used to estimate the average illuminance level on workplane and correlate it with the expected saving energy in buildings. The study concluded that there is an optimal orientation for shading devices that keeps the internal illuminance level within the acceptable range with minimum amount of solar heat gain. (author)

  1. Influence of Compression Ratio on High Load Performance and Knock Behavior for Gasoline Port-Fuel Injection, Natural Gas Direct Injection and Blended Operation in a Spark Ignition Engine

    Energy Technology Data Exchange (ETDEWEB)

    Pamminger, Michael; Sevik, James; Scarcelli, Riccardo; Wallner, Thomas; Hall, Carrie

    2017-03-28

    Natural Gas (NG) is an alternative fuel which has attracted a lot of attention recently, in particular in the US due to shale gas availability. The higher hydrogen-to-carbon (H/C) ratio, compared to gasoline, allows for decreasing carbon dioxide emissions throughout the entire engine map. Furthermore, the high knock resistance of NG allows increasing the efficiency at high engine loads compared to fuels with lower knock resistance. NG direct injection (DI) allows for fuel to be added after intake valve closing (IVC) resulting in an increase in power density compared to an injection before IVC. Steady-state engine tests were performed on a single-cylinder research engine equipped with gasoline (E10) port-fuel injection (PFI) and NG DI to allow for in-cylinder blending of both fuels. Knock investigations were performed at two discrete compression ratios (CR), 10.5 and 12.5. Operating conditions span mid-load, wide-open-throttle and boosted conditions, depending on the knock response of the fuel blend. Blended operation was performed using E10 gasoline and NG. An additional gasoline type fuel (E85) with higher knock resistance than E10 was used as a high-octane reference fuel, since the octane rating of E10-NG fuel blends is unknown. Spark timing was varied at different loads under stoichiometric conditions in order to study the knock response as well as the effects on performance and efficiency. As anticipated, results suggest that the knock resistance can be increased significantly by increasing the NG amount. Comparing the engine operation with the least knock resistant fuel, E10 PFI, and the fuel blend with the highest knock resistance, 75% NG DI, shows an increase in indicated mean effective pressure of about 9 bar at CR 12.5. The usage of reference fuels with known knock characteristics allowed an assessment of knock characteristic of intermediate E10-NG blend levels. Mathematical correlations were developed allowing characterizing the occurrence of knocking

  2. Effect of internal woven roller shade and glazing on the energy and daylighting performances of an office building in the cold climate of Shillong

    International Nuclear Information System (INIS)

    Singh, Ramkishore; Lazarus, I.J.; Kishore, V.V.N.

    2015-01-01

    Highlights: • We simulated a number of glazing and interior roller shade alternatives. • Office room has been simulated for three window-to-wall ratios in a cold climate. • Daylighting and energy performances have been assessed for each alternative. • Maximum energy savings have been estimated in the office with a 30% glazed area. • Energy saving decreases for larger glazed area and fabric transmittance. - Abstract: The energy and visual performances of the façades are defined by many parameters including façade size, properties of glazings and shadings, and their arrangements as well as control strategies. In this study, a number of combinations of internal woven roller shades and four double glazings have been proposed and assessed in integrated manner in order to improve the energy efficiency and visual comfort in new or existing office buildings. Office rooms facing south, east, north and west have been simulated for cold climate, by varying glazed areas and proposed glazing and shading alternatives. Results have been calculated, compared and analyzed in terms of the energy consumptions, energy saving potentials, daylight autonomy, useful daylight illuminance and discomfort glare free time, for each of the combinations. Simulation results show that the choice of glazing and shading alternatives can have substantial impact on energy and visual performances of the office space. Regardless of façade orientation, the maximum energy saving is achieved for a window-to-wall ratio (WWR) of 30%. Saving potential decreases significantly for larger glazed area and for each façade orientation. For all façade orientations and glazed areas (except for 30% WWR in the north wall), a bare low-e coated double glazing (U = 1.616 W/m"2 K, SHGC = 0.209, τ_v = 0.301) is found to be the most energy efficient choice. For 30% north glazing, the energy efficiency can be maximized with a different bare low-e coated double glazing (U = 1.628 W/m"2 K, SHGC = 0.370, τ_v = 0

  3. Year-round daylight saving time will save more energy in India than corresponding DST or time zones

    International Nuclear Information System (INIS)

    Ahuja, Dilip R.; SenGupta, D.P.

    2012-01-01

    Many countries have experimented with daylight saving time (DST) to save energy and to align human activities more closely to the daily cycle of light and darkness. Using a novel methodology, we estimate the year-round energy savings to be obtained from advancing Indian Standard Time (IST), from the introduction of DST, and from dividing the country into two time zones. We find that the option of advancing IST consistently saves more energy than the corresponding DST option, which in turn saves more energy than the corresponding time zones option. This is because the energy benefits of advancing IST accrue for the entire year throughout the country, whereas the benefits of DST are confined to summer months and the benefits of two time zones are largely in the lower energy consuming eastern region. We recommend advancing IST by half-hour to being six hours ahead of UTC. This confers the advantages of DST and time zones without their disadvantages and is forecast to save more than 2 billion kWh of electricity every year during evening peaks that are difficult to supply. While these results are India-specific, similar exercises would be useful to many other countries. - Highlights: ► Advancing IST (YRDST) consistently saves more energy than the corresponding DST. ► DST consistently saves more energy than dividing India into two time zones. ► There are also many non-energy benefits of advancing IST. ► Results are for India; countries with DST may find it useful to consider YRDST.

  4. Organic Light-Emitting Diode with Color Tunable between Bluish-White Daylight and Orange-White Dusk Hue

    Directory of Open Access Journals (Sweden)

    Shih-Yun Liao

    2014-01-01

    Full Text Available The varying color of sunlight diurnally exhibits an important effect on circadian rhythm of living organisms. The bluish-white daylight that is suitable for work shows a color temperature as high as 9,000 K, while the homey orange-white dusk hue is as low as 2,000 K. We demonstrate in this report the feasibility of using organic light-emitting diode (OLED technology to fabricate sunlight-style illumination with a very wide color temperature range. The color temperature can be tuned from 2,300 K to 9,300 K, for example, by changing the applied voltage from 3 to 11 V for the device composing red and yellow emitters in the first emissive layer and blue emitter in the second. Unlike the prior arts, the color-temperature span can be made much wider without any additional carrier modulation layer, which should enable a more cost effective fabrication. For example, the color-temperature span is 7,000 K for the above case, while it is 1,700 K upon the incorporation of a nanoscale hole modulation layer in between the two emissive layers. The reason why the present device can effectively regulate the shifting of recombination zone is because the first emissive layer itself possesses an effective hole modulation barrier of 0.2 eV. This also explains why the incorporation of an extra hole modulation layer with a 0.7 eV barrier did not help extend the desirable color-temperature span since excessive holes may be blocked.

  5. Load testing circuit

    DEFF Research Database (Denmark)

    2009-01-01

    A load testing circuit a circuit tests the load impedance of a load connected to an amplifier. The load impedance includes a first terminal and a second terminal, the load testing circuit comprising a signal generator providing a test signal of a defined bandwidth to the first terminal of the load...

  6. La representación de la luz natural en el proyecto arquitectónico

    OpenAIRE

    Meneses Bedoya, Edgar Alonso

    2016-01-01

    The representation of natural light is placed in the context of architectural drawing, showing that despite the leading role of daylight in architecture, the representation of its phenomenology was limited to the geometric layout of the shadows in space; however, with the addition of IT technology and virtual simulation, this representation takes on a new communicative dimension through the use of realistic images that can represent phenomenology light as it is perceived and assist the archit...

  7. electrical load survey electrical load survey and forecast

    African Journals Online (AJOL)

    eobe

    scattered nature of the area and low load factor. In this ... employment and allow decentralized production of the ... and viable concept from energy production and .... VII Yr. ×. kWh. VIII Yr. ×. kWh. IX Yr. ×. kWh. X Yr. ×. kWh. 1. Residential. 147.

  8. Sustainable building with closed cavity facades. Top energy efficiency and more daylight; Nachhaltig bauen mit Closed Cavity Fassaden. Hoechste Energieeffizienz und mehr Tageslicht

    Energy Technology Data Exchange (ETDEWEB)

    Rudolf, Bernhard

    2012-08-15

    Facades have a key function within the sustainable construction since the energy conservation significantly depends on the building envelope. Beside an enhanced energy efficiency, the Green Building shall offer an improved utilization of day-lighting and comfortable indoor climatic conditions. Here, the innovative Closed Cavity Facade new standards. The former 'Poseidon building' in Frankfurt/Main (Federal Republic of Germany) and the multi-storey building of the Roche company in Basel (Switzerland) are equipped with this facade. The energy costs, operational costs as well as the maintenance costs are reduced sustainably using this closed bivalved facade.

  9. Loads and loads and loads: The influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Directory of Open Access Journals (Sweden)

    Beat eMeier

    2015-06-01

    Full Text Available In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load can affect prospective memory performance. The existence of multiple target events increases prospective load and adding complexity to the to-be-remembered action increases retrospective load. In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of prospective load on costs in the ongoing task for categorical targets (Experiment 2, but not for specific targets (Experiment 1. Retrospective load and ongoing task load both affected remembering the retrospective component of the prospective memory task. We suggest that prospective load can enhance costs in the ongoing task due to additional monitoring requirements. Retrospective load and ongoing task load seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  10. Daylight Redirecting Window Films

    Science.gov (United States)

    2013-09-01

    28 4.1.3 Fort Bliss , TX .......................................................................................29 4.1.4 Marine Corps Air Ground...Norfolk; Shawn Bogdan, Matt Siler and Kyle Hess at Naval War College, Newport; Marisela Leyva at Fort Bliss , TX; Clovis Vaughn and Andrew Burton at...team at Heschong Mahone Group (now part of TRC Companies): Lisa Heschong, Abhijeet Pande, Mudit Agarwal and Tim Perry for their immense contribution

  11. Daylight Redirecting Window Film

    Science.gov (United States)

    2013-12-01

    Fort Bliss , TX; Clovis Vaughn and Andrew Burton at 29 Palms, CA; Doug Taber at Naval Post Graduate School (NPS), Monterey; and Mitch Hailey at Naval...Agarwal and Tim Perry for their immense contribution to this project. Finally, throughout the project, the guidance and counseling of Vern Novstrup at...and control) VA Norfolk Z-133 1 1 1 6 72 48 120 CA 29 Palms 1416 5 7 14 13 108 31 62 RI Newport Hewitt Hall 2 5 9 19 88 24 40 TX Fort Bliss

  12. Wind Structure and Wind Loading

    DEFF Research Database (Denmark)

    Brorsen, Michael

    The purpose of this note is to provide a short description of wind, i.e. of the flow in the atmosphere of the Earth and the loading caused by wind on structures. The description comprises: causes to the generation of windhe interaction between wind and the surface of the Earthhe stochastic nature...

  13. Sunscope natural light systems : tubular skylights

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This brochure described a tubular skylight designed by Sunscope Natural Light Systems. The Sunscope is a super-reflective light system in which daylight is reflected down a cylinder to a translucent ceiling fixture that diffuses natural light throughout the room in which it is placed. The Sunscope requires no structure changes, is installed in less than 3 hours, and requires no drywall repairs or repainting. The system eliminates the need for daytime electric lighting, and causes no winter heat losses or summer heat gains. Available in 3 sizes, the Sunscope has no moving parts and is fully maintenance-free. The system was designed for use in commercial and residential applications. 7 figs.

  14. One-pot solvothermal synthesis of highly efficient, daylight active and recyclable Ag/AgBr coupled photocatalysts with synergistic dual photoexcitation

    International Nuclear Information System (INIS)

    Zhang, Caihong; Ai, Lunhong; Li, Lili; Jiang, Jing

    2014-01-01

    Highlights: • Ag/AgBr photocatalysts were controllably synthesized by solvothermal process. • Ag/AgBr composites showed excellent daylight driven photocatalytic activity. • The remarkable activity is attributed to the synergistic dual photoexcitation. -- Abstract: Efficient light harvesting has been considered to be critical for manipulating the photocatalytic behavior of photocatalysts, because it directly determines the generation of reactive redox charge carriers involved in photoreaction process. In this study, we present a successful example on efficient conversion of solar energy by Ag/AgBr coupled photocatalysts that hold unique synergistic dual photoexcitation. A series of Ag/AgBr coupled photocatalysts were controllably synthesized by an easily manipulated mild solvothermal process. The physicochemical properties of the as-prepared Ag/AgBr coupled photocatalysts were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS) and UV–vis diffuse reflectance spectroscopy (DRS). The results showed the solvothermal reaction time played key role for control of crystalline structure, morphology, composition, and visible light absorption ability of the resulting photocatalysts. The as-prepared Ag/AgBr coupled photocatalysts exhibited remarkable photocatalytic performance and good reusability for decomposing organic dyes in aqueous solution under the irradiation of commercial 20 W cool daylight fluorescent lamp, owing to the synergistic dual photoexcitation cooperating between plasmonic Ag nanoparticles and narrow-band-gap AgBr

  15. Natural light illumination system.

    Science.gov (United States)

    Whang, Allen Jong-Woei; Chen, Yi-Yung; Yang, Shu-Hua; Pan, Po-Hsuan; Chou, Kao-Hsu; Lee, Yu-Chi; Lee, Zong-Yi; Chen, Chi-An; Chen, Cheng-Nan

    2010-12-10

    In recent years, green energy has undergone a lot of development and has been the subject of many applications. Many research studies have focused on illumination with sunlight as a means of saving energy and creating healthy lighting. Natural light illumination systems have collecting, transmitting, and lighting elements. Today, most daylight collectors use dynamic concentrators; these include Sun tracking systems. However, this design is too expensive to be cost effective. To create a low-cost collector that can be easily installed on a large building, we have designed a static concentrator, which is prismatic and cascadable, to collect sunlight for indoor illumination. The transmission component uses a large number of optical fibers. Because optical fibers are expensive, this means that most of the cost for the system will be related to transmission. In this paper, we also use a prismatic structure to design an optical coupler for coupling n to 1. With the n-to-1 coupler, the number of optical fibers necessary can be greatly reduced. Although this new natural light illumination system can effectively guide collected sunlight and send it to the basement or to other indoor places for healthy lighting, previously there has been no way to manage the collected sunlight when lighting was not desired. To solve this problem, we have designed an optical switch and a beam splitter to control and separate the transmitted light. When replacing traditional sources, the lighting should have similar characteristics, such as intensity distribution and geometric parameters, to those of traditional artificial sources. We have designed, simulated, and optimized an illumination lightpipe with a dot pattern to redistribute the collected sunlight from the natural light illumination system such that it equals the qualities of a traditional lighting system. We also provide an active lighting module that provides lighting from the natural light illumination system or LED auxiliary

  16. Synthetic jet actuation for load control

    NARCIS (Netherlands)

    de Vries, Hein; van der Weide, Edwin Theodorus Antonius; Hoeijmakers, Hendrik Willem Marie

    2014-01-01

    The reduction of wind turbine blade loads is an important issue in the reduction of the costs of energy production. Reduction of the loads of a non-cyclic nature requires so-called smart rotor control, which involves the application of distributed actuators and sensors to provide fast and local

  17. Distribution load estimation (DLE)

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A; Lehtonen, M [VTT Energy, Espoo (Finland)

    1998-08-01

    The load research has produced customer class load models to convert the customers` annual energy consumption to hourly load values. The reliability of load models applied from a nation-wide sample is limited in any specific network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to find improvements to the load models or, in general, improvements to the load estimates. In Distribution Load Estimation (DLE) the measurements from the network are utilized to improve the customer class load models. The results of DLE will be new load models that better correspond to the loading of the distribution network but are still close to the original load models obtained by load research. The principal data flow of DLE is presented

  18. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A. [VTT Energy, Espoo (Finland)

    1996-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  19. Distribution load estimation - DLE

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, A [VTT Energy, Espoo (Finland)

    1997-12-31

    The load research project has produced statistical information in the form of load models to convert the figures of annual energy consumption to hourly load values. The reliability of load models is limited to a certain network because many local circumstances are different from utility to utility and time to time. Therefore there is a need to make improvements in the load models. Distribution load estimation (DLE) is the method developed here to improve load estimates from the load models. The method is also quite cheap to apply as it utilises information that is already available in SCADA systems

  20. Temperatura de color correlacionada de la luz natural: análisis dinámico en espacios interiores

    Directory of Open Access Journals (Sweden)

    Monteoliva, J. M.

    2015-12-01

    Full Text Available Currently daylight studies are focused on visual amenity. This new trend arises from the need of professionals and researchers to define indicators of daylight quality. One such indicator is the correlated color temperature (CCT. In this paper, the influence of windows orientation and shading systems in color perception of the environment (CCT is discussed. To achieve this goal a dynamic (spatial and temporal characterization methodology of daylight source CCT is proposed. The analysis was performed on a scale model of an indoor space, under clear sky conditions. Results showed the importance of the window orientation in the indoor CCT of daylight, obtaining variations of up to 50 %. It is also noted that shading device cause changes in indoor configurations and sensations. Also here the impact of shading systems and glass on the TCC of natural light entering a space was analyzedActualmente los estudios de la iluminación natural focalizan en la amabilidad visual del espacio. Esta nueva tendencia surge de la necesidad de profesionales e investigadores de definir indicadores de la calidad de la iluminación natural. Uno de ellos es la temperatura de color correlacionada (TCC. En este trabajo, se propone analizar la influencia de la orientación de las ventanas y sus sistemas de sombreado en la percepción de color del ambiente (TCC. Para ello se propone una metodología de caracterización dinámica (espacial y temporal de la TCC de la fuente luz natural. El análisis se desarrolló en un modelo a escala de un espacio interior, bajo condiciones de cielo claro. Los resultados han evidenciado la importancia de la orientación de la ventana en la TCC de un espacio, obteniendo variaciones de hasta el 50 %. De manera complementaria, se detecta la capacidad de modificar la TCC de los ambientes interiores que poseen las superficies vidriadas y los dispositivos de control solar.

  1. Energy efficiency analysis of reconfigured distribution system for practical loads

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2016-09-01

    Full Text Available In deregulated rate structure, the performance evaluation of distribution system for energy efficiency includes; loss minimization, improved power quality, loadability limit, reliability and availability of supply. Energy efficiency changes with the variation in loading pattern and the load behaviour. Further, the nature of load at each node is not explicitly of any one type rather their characteristics depend upon the node voltages. In most cases, load is assumed to be constant power (real and reactive. In this paper voltage dependent practical loads are represented with composite load model and the energy efficiency performance of distribution system for practical loads is evaluated in different configurations of 33-node system.

  2. Study of elevated temperature design standard against thermal loads

    International Nuclear Information System (INIS)

    Kasahara, Naoto; Asayama, Tai; Morishita, Masaki

    2001-01-01

    Elevated temperature components must be designed against both pressure and thermal loads. In the case of sodium circuits of fast breeder reactors, a restriction from the pressure load becomes small because of the high boiling point of sodium. Design approaches for thermal loads (displacement-controlled) are compared with those against pressure loads (load-controlled). Considering differences between those two approaches, a concept of the elevated temperature design standard that takes the nature of thermal loads fully into account is proposed. This concept is a basis of load evaluation techniques and an inelastic analysis guide, that are being developed. Finally, problems and plans to realize the above concept are discussed. (author)

  3. Quantifying the radiant exposure and effective dose in patients treated for actinic keratoses with topical photodynamic therapy using daylight and LED white light

    Science.gov (United States)

    Manley, M.; Collins, P.; Gray, L.; O'Gorman, S.; McCavana, J.

    2018-02-01

    Daylight photodynamic therapy (dl-PDT) is as effective as conventional PDT (c-PDT) for treating actinic keratoses but has the advantage of reducing patient discomfort significantly. Topical dl-PDT and white light-PDT (wl-PDT) differ from c-PDT by way of light sources and methodology. We measured the variables associated with light dose delivery to skin surface and influence of geometry using a radiometer, a spectral radiometer and an illuminance meter. The associated errors of the measurement methods were assessed. The spectral and spatial distribution of the radiant energy from the LED white light source was evaluated in order to define the maximum treatment area, setup and treatment protocol for wl-PDT. We compared the data with two red LED light sources we use for c-PDT. The calculated effective light dose is the product of the normalised absorption spectrum of the photosensitizer, protoporphyrin IX (PpIX), the irradiance spectrum and the treatment time. The effective light dose from daylight ranged from 3  ±  0.4 to 44  ±  6 J cm-2due to varying weather conditions. The effective light dose for wl-PDT was reproducible for treatments but it varied across the treatment area between 4  ±  0.1 J cm-2 at the edge and 9  ±  0.1 J cm-2 centrally. The effective light dose for the red waveband (615-645 nm) was 0.42  ±  0.05 J cm-2 on a clear day, 0.05  ±  0.01 J cm-2 on an overcast day and 0.9  ±  0.01 J cm-2 using the white light. This compares with 0.95  ±  0.01 and 0.84  ±  0.01 J cm-2 for c-PDT devices. Estimated errors associated with indirect determination of daylight effective light dose were very significant, particularly for effective light doses less than 5 J cm-2 (up to 83% for irradiance calculations). The primary source of error is in establishment of the relationship between irradiance or illuminance and effective dose. Use of the O’Mahoney model is recommended using a

  4. Shot loading platform analysis

    International Nuclear Information System (INIS)

    Norman, B.F.

    1994-01-01

    This document provides the wind/seismic analysis and evaluation for the shot loading platform. Hand calculations were used for the analysis. AISC and UBC load factors were used in this evaluation. The results show that the actual loads are under the allowable loads and all requirements are met

  5. Fifty years of genetic load

    International Nuclear Information System (INIS)

    Wallace, B.

    1991-01-01

    This book discusses the radiation effects on Drosophila. It was originally thought that irradiating Drosophila would decrease the average fitness of the population, thereby leading to information about the detrimental effects of mutations. Surprisingly, the fitness of the irradiated population turned out to be higher than that of the control population. The original motivation for the experiment was as a test of genetic load theory. The average fitness of a population is depressed by deleterious alleles held in the population by the balance between mutation and natural selection. The depression is called the genetic load of the population. The load dose not depend on the magnitude of the deleterious effect of alleles, but only on the mutation rate

  6. Marian E. Koshland Integrated Natural Science Center at Haverford College, Haverford, Pennsylvania

    Energy Technology Data Exchange (ETDEWEB)

    2005-06-01

    This publication is one a in series of case studies for ''Laboratories for the 21st Century,'' a joint program of the U.S. Environmental Protection Agency and the U.S. Department of Energy. It is geared toward architects and engineers who are familiar with laboratory buildings, and encourages the design, construction, and operation of safe, sustainable, high-performance laboratories. Featured technologies of this laboratory include fume hoods, controls, mechanical systems, electrical loads, sustainable design/planning, and daylighting.

  7. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D.

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially. PMID:26082709

  8. Loads and loads and loads: the influence of prospective load, retrospective load, and ongoing task load in prospective memory.

    Science.gov (United States)

    Meier, Beat; Zimmermann, Thomas D

    2015-01-01

    In prospective memory tasks different kinds of load can occur. Adding a prospective memory task can impose a load on ongoing task performance. Adding ongoing task load (OTL) can affect prospective memory performance. The existence of multiple target events increases prospective load (PL) and adding complexity to the to-be-remembered action increases retrospective load (RL). In two experiments, we systematically examined the effects of these different types of load on prospective memory performance. Results showed an effect of PL on costs in the ongoing task for categorical targets (Experiment 2), but not for specific targets (Experiment 1). RL and OTL both affected remembering the retrospective component of the prospective memory task. We suggest that PL can enhance costs in the ongoing task due to additional monitoring requirements. RL and OTL seem to impact the division of resources between the ongoing task and retrieval of the retrospective component, which may affect disengagement from the ongoing task. In general, the results demonstrate that the different types of load affect prospective memory differentially.

  9. Measurement of alpha-aerosol activity concentration by a moving filter device. Numerical simulation of both filter activity load and continuous monitoring process by compensation of natural activity by means of ABPD and AERD; Bilanzierung der Alpha-Aktivitaetskonzentration der Raumluft mit einem Schrittbandfiltergeraet. Numerische Simulation des Verlaufs der Bestaubung und der kontinuierlichen Auswertung mit Kompensation der natuerlichen Aktivitaet durch ABPD und AERD

    Energy Technology Data Exchange (ETDEWEB)

    Kraut, W.; Schwarz, W. [Duale Hochschule Baden-Wuerttemberg (DHBW), Karlsruhe (Germany). Studiengang Sicherheitswesen; Kraut, B. [Berthold Technologies GmbH und Co.KG, Bad Wildbad (Germany)

    2016-07-01

    Moving filter aerosol monitors offer the advantage of better measurement conditions by reducing the load of dust and activity. But at the same time the dynamical follow up of increasing or decreasing activity air concentrations is getting more complex by superposition oft the filter movement, especially if there are both short lived natural and long lived artificial activity to be monitored. The paper shows by a pure numerical simulation of activity load and measurement of Radon-daughters and long lived artificial activity, that a stable determination of activity concentration is possible right from the beginning of sampling. This is accomplished by multivariate regression analysis to separate short lived Po-218 and long lived artificial - Activity. Po-214 activity is compensated by means of ABPD and AERD techniques. The Model allows for variable activity concentrations during sampling. Results are presented.

  10. Wind Loads on Structures

    DEFF Research Database (Denmark)

    Dyrbye, Claes; Hansen, Svend Ole

    Wind loads have to be taken into account when designing civil engineering structures. The wind load on structures can be systematised by means of the wind load chain: wind climate (global), terrain (wind at low height), aerodynamic response (wind load to pressure), mechanical response (wind...... pressure to structural response) and design criteria. Starting with an introduction of the wind load chain, the book moves on to meteorological considerations, atmospheric boundary layer, static wind load, dynamic wind load and scaling laws used in wind-tunnel tests. The dynamic wind load covers vibrations...... induced by wind turbulence, vortex shedding, flutter and galloping. The book gives a comprehensive treatment of wind effects on structures and it will be useful for consulting engineers designing wind-sensitive structures. It will also be valuable for students of civil engineering as textbook...

  11. Carbohydrate-Loading Diet

    Science.gov (United States)

    ... Grape juice (12 ounces) 55 225 Lunch Milk, chocolate, reduced fat (12 ounces) 45 285 4 slices ... usual during carbohydrate loading to get the same benefits as a man does. Despite carbohydrate loading, you ...

  12. Autonomous Propellant Loading Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The AES Autonomous Propellant Loading (APL) project consists of three activities. The first is to develop software that will automatically control loading of...

  13. Fuel pellet loading apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus is described for loading a predetermined amount of nuclear fuel pellets into nuclear fuel elements and particularly for the automatic loading of fuel pellets from within a sealed compartment. (author)

  14. Limit loads in nozzles

    International Nuclear Information System (INIS)

    Zouain, N.

    1983-01-01

    The static method for the evaluation of the limit loads of a perfectly elasto-plastic structure is presented. Using the static theorem of Limit Analysis and the Finite Element Method, a lower bound for the colapso load can be obtained through a linear programming problem. This formulation if then applied to symmetrically loaded shells of revolution and some numerical results of limit loads in nozzles are also presented. (Author) [pt

  15. Working memory load modulates microsaccadic rate.

    Science.gov (United States)

    Dalmaso, Mario; Castelli, Luigi; Scatturin, Pietro; Galfano, Giovanni

    2017-03-01

    Microsaccades are tiny eye movements that individuals perform unconsciously during fixation. Despite that the nature and the functions of microsaccades are still lively debated, recent evidence has shown an association between these micro eye movements and higher order cognitive processes. Here, in two experiments, we specifically focused on working memory and addressed whether differential memory load could be reflected in a modulation of microsaccade dynamics. In Experiment 1, participants memorized a numerical sequence composed of either two (low-load condition) or five digits (high-load condition), appearing at fixation. The results showed a reduction in the microsaccadic rate in the high-load compared to the low-load condition. In Experiment 2, five red or green digits were always presented at fixation. Participants either memorized the color (low-load condition) or the five digits (high-load condition). Hence, visual stimuli were exactly the same in both conditions. Consistent with Experiment 1, microsaccadic rate was lower in the high-load than in the low-load condition. Overall, these findings reveal that an engagement of working memory can have an impact on microsaccadic rate, consistent with the view that microsaccade generation is pervious to top-down processes.

  16. Spatial electric load forecasting

    CERN Document Server

    Willis, H Lee

    2002-01-01

    Spatial Electric Load Forecasting Consumer Demand for Power and ReliabilityCoincidence and Load BehaviorLoad Curve and End-Use ModelingWeather and Electric LoadWeather Design Criteria and Forecast NormalizationSpatial Load Growth BehaviorSpatial Forecast Accuracy and Error MeasuresTrending MethodsSimulation Method: Basic ConceptsA Detailed Look at the Simulation MethodBasics of Computerized SimulationAnalytical Building Blocks for Spatial SimulationAdvanced Elements of Computerized SimulationHybrid Trending-Simulation MethodsAdvanced

  17. Cognitive Load and Cooperation

    DEFF Research Database (Denmark)

    Døssing, Felix Sebastian; Piovesan, Marco; Wengström, Erik Roland

    2017-01-01

    We study the effect of intuitive and reflective processes on cooperation using cognitive load. Compared with time constraint, which has been used in the previous literature, cognitive load is a more direct way to block reflective processes, and thus a more suitable way to study the link between...... intuition and cooperation. Using a repeated public goods game, we study the effect of different levels of cognitive load on contributions. We show that a higher cognitive load increases the initial level of cooperation. In particular, subjects are significantly less likely to fully free ride under high...... cognitive load....

  18. Optimisation of load control

    International Nuclear Information System (INIS)

    Koponen, P.

    1998-01-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  19. Optimisation of load control

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland)

    1998-08-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  20. The methodology for the evaluation of the energy saving by the daylight saving time in Mexico; Metodologia para la evaluacion del ahorro de energia debido al cambio de horario durante la epoca del verano

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    A description is made of the methodology for the evaluation of energy saving by the daylight saving time in Mexico. A mathematical model was developed that would allow the quantitative evaluation of the energy saving by the daylight saving time, through measurements of the consumption of different users from the domestic commercial and industrial sector, considering the various variables that impact the consumption [Espanol] Se describe la metodologia para la evalucion del ahorro de energia por el cambio de horario de verano en Mexico. Se desarrollo un modelo matematico que permitiera evaluar cuantitativamente el ahorro de energia debido al cambio de horario durante la epoca de verano, atraves de mediciones de consumos de los diferentes usuarios de los sectores domestico, comercial e industrial, considerando las diversas variables que impactan en el consumo

  1. The methodology for the evaluation of the energy saving by the daylight saving time in Mexico; Metodologia para la evaluacion del ahorro de energia debido al cambio de horario durante la epoca del verano

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    A description is made of the methodology for the evaluation of energy saving by the daylight saving time in Mexico. A mathematical model was developed that would allow the quantitative evaluation of the energy saving by the daylight saving time, through measurements of the consumption of different users from the domestic commercial and industrial sector, considering the various variables that impact the consumption [Espanol] Se describe la metodologia para la evalucion del ahorro de energia por el cambio de horario de verano en Mexico. Se desarrollo un modelo matematico que permitiera evaluar cuantitativamente el ahorro de energia debido al cambio de horario durante la epoca de verano, atraves de mediciones de consumos de los diferentes usuarios de los sectores domestico, comercial e industrial, considerando las diversas variables que impactan en el consumo

  2. Daylight and solar control in buildings. General evaluation and optimization of a new angle selective glazing facade

    Energy Technology Data Exchange (ETDEWEB)

    Frontini, Francesco

    2011-07-01

    Buildings account for almost 40% of the overall energy consumption in Europe. For the future energy scenarios, the building envelope, especially the facades, becomes really important as it provides the necessary area for the installation of PV modules or solar collectors to produce energy, using renewable energy sources. A new multifunctional building integrated photovoltaic (BIPV) glazed facade for this application is presented here. The new angle-selective see through facade combines four important tasks in one element: solar control, glare protection, visual contact and electricity generation. Mathematical analysis and complex simulations with the software Radiance are performed to optimize the geometry and to assess the visual impact and optical properties of the new window. In order to evaluate the impact of the new facade in building spaces a new method for modelling the total solar energy transmittance, in building energy simulations software, for complex glazing facades is presented. The new black-box-model (BBM) is implemented into ESP-r software and is validated. The BBM is used to assess the impact of modelling accurately the g-value of complex facade within building simulation. It is shown that the new method can significantly increase the accuracy of heating/cooling loads and room temperatures. (orig.)

  3. Experimental analysis on a 1:2 scale model of the double light pipe, an innovative technological device for daylight transmission

    Energy Technology Data Exchange (ETDEWEB)

    Baroncini, C.; Boccia, O.; Chella, F.; Zazzini, P. [D.S.S.A.R.R. Faculty of Architecture, University ' ' G. D' Annunzio' ' Viale Pindaro 42, 65127 Pescara (Italy)

    2010-02-15

    In this paper the authors present the double light pipe, an innovative technological device, designed as an evolution of a traditional light pipe, which distributes daylight to underground areas of a building, illuminating, at the same time, the passage areas thanks to a larger collector and a second transparent pipe attached to the first one. Unlike the traditional light pipe, thanks to this double illuminating function it can be located in the middle of a room, despite its encumbrance. In this paper the technological design of the double light pipe is presented and the results of an experimental analysis on a reduced scale (1:2) model are shown. Internal illuminance data over horizontal and vertical work-planes were measured in various sky conditions with or without direct solar radiation. Being this innovative device obtained by a light pipe integrated with a second pipe, it performs like a traditional light pipe for the final room and, at the same time, illuminates the intermediate room giving it uniform and high quality light, particularly indicated for wide plant areas, such as show-rooms or museums. (author)

  4. Relative roles of emissions and meteorology in the diurnal pattern of urban PM10: analysis of the daylight saving time effect.

    Science.gov (United States)

    Muñoz, Ricardo C

    2012-06-01

    Daylight saving time (DST) is a common practice in many countries, in which Official Time (OT) is abruptly shifted 1 hour with respect to solar time on two occasions every year (in fall and spring). All anthropogenic emitting processes tied to OT like job and school commuting traffic, abruptly change in this moment their timing with respect to solar time, inducing a sudden shift between emissions and the meteorological factors that control the dispersion and transport of air pollutants. Analyzing 13 years of hourly particulate matter (PM10) concentrations measured in Santiago, Chile, we demonstrate that the DST practice has observable non-trivial effects in the PM10 diurnal cycle. The clearest impact is in the morning peak of PM10 during the fall DST change, which occurs later and has on average a significant smaller magnitude in the days after the DST change as compared to the days before it. This decrease in magnitude is most remarkable because it occurs in a period of the year when overall PM10 concentrations increase due to generally worsening of the dispersion conditions. Results are shown for seven monitoring stations around the city, and for the fall and spring DST changes. They show clearly the interplay of emissions and meteorology in conditioning urban air pollution problems, highlighting the role of the morning and evening transitions of the atmospheric boundary layer in shaping the diurnal pattern of urban air pollutant concentrations.

  5. Concentrated loads on concrete

    DEFF Research Database (Denmark)

    Lorenzen, Karen Grøndahl; Nielsen, Mogens Peter

    1997-01-01

    This report deals with concentrated loads on concrete.A new upper bound solution in the axisymmetrical case of a point load in the center of the end face of a cylinder is developed.Based on previous work dealing with failure mechanisms and upper bound solutions, new approximate formulas are devel......This report deals with concentrated loads on concrete.A new upper bound solution in the axisymmetrical case of a point load in the center of the end face of a cylinder is developed.Based on previous work dealing with failure mechanisms and upper bound solutions, new approximate formulas...

  6. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  7. Load regulating expansion fixture

    International Nuclear Information System (INIS)

    Wagner, L.M.; Strum, M.J.

    1998-01-01

    A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located there between. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig

  8. Laterally loaded masonry

    DEFF Research Database (Denmark)

    Raun Gottfredsen, F.

    In this thesis results from experiments on mortar joints and masonry as well as methods of calculation of strength and deformation of laterally loaded masonry are presented. The strength and deformation capacity of mortar joints have been determined from experiments involving a constant compressive...... stress and increasing shear. The results show a transition to pure friction as the cohesion is gradually destroyed. An interface model of a mortar joint that can take into account this aspect has been developed. Laterally loaded masonry panels have also been tested and it is found to be characteristic...... that laterally loaded masonry exhibits a non-linear load-displacement behaviour with some ductility....

  9. Electrical load modeling

    Energy Technology Data Exchange (ETDEWEB)

    Valgas, Helio Moreira; Pinto, Roberto del Giudice R.; Franca, Carlos [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Lambert-Torres, Germano; Silva, Alexandre P. Alves da; Pires, Robson Celso; Costa, Junior, Roberto Affonso [Escola Federal de Engenharia de Itajuba, MG (Brazil)

    1994-12-31

    Accurate dynamic load models allow more precise calculations of power system controls and stability limits, which are critical mainly in the operation planning of power systems. This paper describes the development of a computer program (software) for static and dynamic load model studies using the measurement approach for the CEMIG system. Two dynamic load model structures are developed and tested. A procedure for applying a set of measured data from an on-line transient recording system to develop load models is described. (author) 6 refs., 17 figs.

  10. Spatial peak-load pricing

    International Nuclear Information System (INIS)

    Arellano, M. Soledad; Serra, Pablo

    2007-01-01

    This article extends the traditional electricity peak-load pricing model to include transmission costs. In the context of a two-node, two-technology electric power system, where suppliers face inelastic demand, we show that when the marginal plant is located at the energy-importing center, generators located away from that center should pay the marginal capacity transmission cost; otherwise, consumers should bear this cost through capacity payments. Since electric power transmission is a natural monopoly, marginal-cost pricing does not fully cover costs. We propose distributing the revenue deficit among users in proportion to the surplus they derive from the service priced at marginal cost. (Author)

  11. Load Balancing in Hypergraphs

    Science.gov (United States)

    Delgosha, Payam; Anantharam, Venkat

    2018-03-01

    Consider a simple locally finite hypergraph on a countable vertex set, where each edge represents one unit of load which should be distributed among the vertices defining the edge. An allocation of load is called balanced if load cannot be moved from a vertex to another that is carrying less load. We analyze the properties of balanced allocations of load. We extend the concept of balancedness from finite hypergraphs to their local weak limits in the sense of Benjamini and Schramm (Electron J Probab 6(23):13, 2001) and Aldous and Steele (in: Probability on discrete structures. Springer, Berlin, pp 1-72, 2004). To do this, we define a notion of unimodularity for hypergraphs which could be considered an extension of unimodularity in graphs. We give a variational formula for the balanced load distribution and, in particular, we characterize it in the special case of unimodular hypergraph Galton-Watson processes. Moreover, we prove the convergence of the maximum load under some conditions. Our work is an extension to hypergraphs of Anantharam and Salez (Ann Appl Probab 26(1):305-327, 2016), which considered load balancing in graphs, and is aimed at more comprehensively resolving conjectures of Hajek (IEEE Trans Inf Theory 36(6):1398-1414, 1990).

  12. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1985-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years. 23 refs., 9 tabs

  13. Load Induced Blindness

    Science.gov (United States)

    Macdonald, James S. P.; Lavie, Nilli

    2008-01-01

    Although the perceptual load theory of attention has stimulated a great deal of research, evidence for the role of perceptual load in determining perception has typically relied on indirect measures that infer perception from distractor effects on reaction times or neural activity (see N. Lavie, 2005, for a review). Here we varied the level of…

  14. Structural load combinations

    International Nuclear Information System (INIS)

    Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

    1986-01-01

    This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane earthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10 -6 or 1.0 x 10 -5 during a lifetime of 40 years

  15. Load event: Aircraft crash

    International Nuclear Information System (INIS)

    Fritsch, H.

    1985-01-01

    The bibliography includes 48 quotations, up to the year 1983, on the following issues: Experiments and computational methods. Design load for the dimensioning of reinforced concrete buildings and components with respect to the dynamic load in the event of an aircraft crash. (orig./HP) [de

  16. Fiber Bundle Model Under Heterogeneous Loading

    Science.gov (United States)

    Roy, Subhadeep; Goswami, Sanchari

    2018-03-01

    The present work deals with the behavior of fiber bundle model under heterogeneous loading condition. The model is explored both in the mean-field limit as well as with local stress concentration. In the mean field limit, the failure abruptness decreases with increasing order k of heterogeneous loading. In this limit, a brittle to quasi-brittle transition is observed at a particular strength of disorder which changes with k. On the other hand, the model is hardly affected by such heterogeneity in the limit where local stress concentration plays a crucial role. The continuous limit of the heterogeneous loading is also studied and discussed in this paper. Some of the important results related to fiber bundle model are reviewed and their responses to our new scheme of heterogeneous loading are studied in details. Our findings are universal with respect to the nature of the threshold distribution adopted to assign strength to an individual fiber.

  17. Load Balancing Scientific Applications

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Olga Tkachyshyn [Texas A & M Univ., College Station, TX (United States)

    2014-12-01

    The largest supercomputers have millions of independent processors, and concurrency levels are rapidly increasing. For ideal efficiency, developers of the simulations that run on these machines must ensure that computational work is evenly balanced among processors. Assigning work evenly is challenging because many large modern parallel codes simulate behavior of physical systems that evolve over time, and their workloads change over time. Furthermore, the cost of imbalanced load increases with scale because most large-scale scientific simulations today use a Single Program Multiple Data (SPMD) parallel programming model, and an increasing number of processors will wait for the slowest one at the synchronization points. To address load imbalance, many large-scale parallel applications use dynamic load balance algorithms to redistribute work evenly. The research objective of this dissertation is to develop methods to decide when and how to load balance the application, and to balance it effectively and affordably. We measure and evaluate the computational load of the application, and develop strategies to decide when and how to correct the imbalance. Depending on the simulation, a fast, local load balance algorithm may be suitable, or a more sophisticated and expensive algorithm may be required. We developed a model for comparison of load balance algorithms for a specific state of the simulation that enables the selection of a balancing algorithm that will minimize overall runtime.

  18. Status of load management

    Energy Technology Data Exchange (ETDEWEB)

    Juchymenko, A

    1983-08-01

    A summary is presented of the status of load management, defined as any activity by an electric utility to affect the size and characteristics of its load. Load management is currently viewed by electric utilities as an important tool for marketing electricity in a competitive fuel situation. A major aim of the National Energy Program is to reduce Canada's dependence on oil by 1990 to 10% of the energy used by all markets. As a result, electricity may play a greater role in the supply of primary energy. Research in load management has been directed mostly towards the residential market, especially direct control of domestic hot water heaters and air conditioners. Studies conducted in Canada and the U.S. to determine user's receptiveness to direct control of loads and thermal energy storage systems indicate that these load management techniques are in most cases not acceptable to customers, who prefer voluntary reduction in demand. The potential exists in the industrial market to use load management to assist in electrifying many of the fossil fuel-fired processes at competitive energy prices. Some of the more important applications include an industrial heat pump to heat liquids to 120{degree}C, induction heating for melting and heat treating of metals, and mechanical vapor recompression equipment to produce proces steam. 21 refs., 2 figs., 2 tabs.

  19. Study on simulation methods of atrium building cooling load in hot and humid regions

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Yiqun; Li, Yuming; Huang, Zhizhong [Institute of Building Performance and Technology, Sino-German College of Applied Sciences, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Wu, Gang [Weldtech Technology (Shanghai) Co. Ltd. (China)

    2010-10-15

    In recent years, highly glazed atria are popular because of their architectural aesthetics and advantage of introducing daylight into inside. However, cooling load estimation of such atrium buildings is difficult due to complex thermal phenomena that occur in the atrium space. The study aims to find out a simplified method of estimating cooling loads through simulations for various types of atria in hot and humid regions. Atrium buildings are divided into different types. For every type of atrium buildings, both CFD and energy models are developed. A standard method versus the simplified one is proposed to simulate cooling load of atria in EnergyPlus based on different room air temperature patterns as a result from CFD simulation. It incorporates CFD results as input into non-dimensional height room air models in EnergyPlus, and the simulation results are defined as a baseline model in order to compare with the results from the simplified method for every category of atrium buildings. In order to further validate the simplified method an actual atrium office building is tested on site in a typical summer day and measured results are compared with simulation results using the simplified methods. Finally, appropriate methods of simulating different types of atrium buildings are proposed. (author)

  20. Lumbriculus variegatus loading study

    Data.gov (United States)

    U.S. Environmental Protection Agency — Results from sediment bioaccumulation tests with Lumbriculus variegatus with evaluating the effects of organism loading density. This dataset is associated with the...

  1. LOADING SIMULATION PROGRAM C

    Science.gov (United States)

    LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for simulating hydrology, sediment, and general water quality

  2. LOADING SIMULATION PROGRAM C

    Data.gov (United States)

    U.S. Environmental Protection Agency — LSPC is the Loading Simulation Program in C++, a watershed modeling system that includes streamlined Hydrologic Simulation Program Fortran (HSPF) algorithms for...

  3. Cognitive load theory

    NARCIS (Netherlands)

    Kirschner, Paul A.; Kirschner, Femke; Paas, Fred

    2010-01-01

    Kirschner, P. A., Kirschner, F. C., & Paas, F. (2009). Cognitive load theory. In E. M. Anderman & L. H. Anderman (Eds.). Psychology of classroom learning: An encyclopedia, Volume 1, a-j (pp. 205-209). Detroit, MI: Macmillan Reference.

  4. Static Loads Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides the capability to perform large-scale structural loads testing on spacecraft and other structures. Results from these tests can be used to verify...

  5. Load proportional safety brake

    Science.gov (United States)

    Cacciola, M. J.

    1979-01-01

    This brake is a self-energizing mechanical friction brake and is intended for use in a rotary drive system. It incorporates a torque sensor which cuts power to the power unit on any overload condition. The brake is capable of driving against an opposing load or driving, paying-out, an aiding load in either direction of rotation. The brake also acts as a no-back device when torque is applied to the output shaft. The advantages of using this type of device are: (1) low frictional drag when driving; (2) smooth paying-out of an aiding load with no runaway danger; (3) energy absorption proportional to load; (4) no-back activates within a few degrees of output shaft rotation and resets automatically; and (5) built-in overload protection.

  6. Plug Load Data

    Data.gov (United States)

    National Aeronautics and Space Administration — We provide MATLAB binary files (.mat) and comma separated values files of data collected from a pilot study of a plug load management system that allows for the...

  7. Harmonics mitigation on industrial loads using series and parallel ...

    African Journals Online (AJOL)

    Most industrial loads are inductive in nature and therefore absorb Volts Ampere Reactance (VARs) leading to lagging power factor. Some inductive loads also produce current and voltage signals with frequencies in integer multiples of the 50 or 60 Hz fundamental frequencies called harmonics. Harmonics in power system ...

  8. Load power device, system and method of load control and management employing load identification

    Science.gov (United States)

    Yang, Yi; Luebke, Charles John; Schoepf, Thomas J.

    2018-01-09

    A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

  9. Comparison between simplified load spectra in accordance with Germanische Lloyd guidelines, and load spectra derived from time domain simulations

    Energy Technology Data Exchange (ETDEWEB)

    Rees, M [Aerodyn Energiesysteme gmbH, Rendsburg (Germany)

    1996-09-01

    The Germanische Lloyd guideline allows calculations of load spectra in two fundamentally different ways. In the case of the so-called `simplified load spectra` the maximum amplitude of fluctuation of a load component is formed as {+-}75% of the average value of the purely aerodynamic loads of this component at rated wind conditions, together with an overlay of mass-related loads. The second method allowed in the GL guideline is the calculation of load spectra from simulation results in the time domain. For a number of average wind speeds the time-dependent characteristics of the load components are calculated taking account of the natural spatial turbulence of the wind. These are converted into load spectra using the rainflow method. In a parametric study the load spectra are calculated according to both methods and compared. The calculations are performed for turbines with rated powers of 100 kW to 2000 kW, with two and three blades, and also for stall-controlled and pitch-controlled turbines. The calculated load spectra are compared with each by means of 1 P fatigue equivalent load spectra. The influence of individual parameters is presented, as is the validity of the simplified load spectra. (au)

  10. Natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, J W

    1967-08-01

    This report on the natural gas industry of Canada includes: composition and uses of natural gas, production statistics, exploration and development, reserve estimates, natural gas processing, transportation, and marketing. For the Canadian natural gas industry, 1966 was a year of moderate expansion in all phases, with a strong demand continuing for sulfur and liquid hydrocarbons produced as by-products of gas processing. Value of natural gas production increased to $199 million and ranked sixth in terms of value of mineral ouput in Canada. Currently, natural gas provides over 70% of Canada's energy requirements. Proved remaining marketable reserves are estimated to be in excess of a 29-yr supply.

  11. Peak load arrangements : Assessment of Nordel guidelines

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    taken after consultation with parties in other Nordic countries, and involving also regulators and TSOs. In NordREG's view there are basically three principles that should be guiding any decision to introduce peak load arrangements in the Nordic countries: i), the peak load arrangements should be introduced only in situations when security of supply cannot be met without these arrangements. Since the decision to introduce peak load arrangements might be of a political/legal nature, the length of such arrangement cannot be fixed. However, there should be a regular evaluation by the competent authority of any need or prolonged need for peak load arrangements and its effects of price formation in the Nordic market. ii), when peak load arrangements are introduced they should be designed to minimize the adverse effects on price formation in the Nordic market. Furthermore, if there are to be peak load arrangements, there might be a need for how to distinguish these peak load reserves from other reserves at the disposal of the TSOs. However, this issue needs further discussions and development. iii), Nordic consultation should be carried out where the views of all relevant authorities and stake holders in the market affected are invited. It is recommended that the governments consult with their Nordic counter parties before submitting legal proposals on peak load arrangements affecting Nordic price formation. These consultations should also be with regulators and TSOs who are involved in the design of the actual peak load arrangements. (Author)

  12. Placing rooms in the right light. Targeted daylight and optimised artificial lighting help to improve comfort; Raeume ins richtige Licht ruecken. Gezielt eingesetztes Tageslicht und optimierte kuenstliche Beleuchtung helfen, das Wohlbefinden zu verbessern

    Energy Technology Data Exchange (ETDEWEB)

    Durst, Anna

    2012-11-01

    Regardless whether in the office, at home or in school, too little daylight or unfavourable lighting impair visibility in rooms and strain the eyes. Based on the example of schools and homes for the elderly, it was investigated how new lighting concepts and new lamp, luminaire and ballast technology can help to improve the situation. A measurement system was used to monitor the lighting and energy properties. The new lighting systems and optimised technology enabled the electrical energy requirements in a school to be reduced by around two thirds. (orig.)

  13. Natural phenomena hazards, Hanford Site, Washington

    International Nuclear Information System (INIS)

    Conrads, T.J.

    1998-01-01

    This document presents the natural phenomena hazard loads for use in implementing DOE Order 5480.28, Natural Phenomena Hazards Mitigation, and supports development of double-shell tank systems specifications at the Hanford Site in south-central Washington State. The natural phenomena covered are seismic, flood, wind, volcanic ash, lightning, snow, temperature, solar radiation, suspended sediment, and relative humidity

  14. Natural Gas

    OpenAIRE

    Bakar, Wan Azelee Wan Abu; Ali, Rusmidah

    2010-01-01

    Natural gas fuel is a green fuel and becoming very demanding because it is environmental safe and clean. Furthermore, this fuel emits lower levels of potentially harmful by-products into the atmosphere. Most of the explored crude natural gas is of sour gas and yet, very viable and cost effective technology is still need to be developed. Above all, methanation technology is considered a future potential treatment method for converting the sour natural gas to sweet natural gas.

  15. Exploring the Impact of Natural Light Exposure on Sleep of Healthy Older Adults: A Field Study

    Directory of Open Access Journals (Sweden)

    Mariëlle P. J. Aarts

    2018-05-01

    Full Text Available Studies among people with dementia demonstrated that the sleep quality and rhythm improves significantly when people are exposed to ambient bright light. Since almost half of the healthy older people also indicate to suffer from chronic sleep disorders, the question arises whether ambient bright light can be beneficial to healthy older people. Particularly the effect on sleep/wake rhythm in relation to the exposure to natural light is the focus. It was hypothesised that the sleep quality would be worse in winter due to a lower daylight dose than in summer due to the lower illuminance and exposure duration. A field study was conducted to examine the relationship between daylight exposure and sleep quality in 14 healthy older adults living independently in their own dwellings in the Netherlands. All participants were asked to take part of the study both during the summer period as well as during the winter period. Therefore, they had to wear an actigraph for five consecutive days which measured sleep, activity and light exposure. Results confirmed that people were significantly longer exposed to high illumination levels (>1000 lx in summer than in winter. Sleep quality measures, however, did not differ significantly between summer and winter. A significant, positive correlation was found between exposure duration to high illuminance from daylight during the day and the sleep efficiency the following night in summer, implying that being exposed to high illuminance for a longer time period has a positive effect on sleep efficiency for the individual data. There was also a tendency of less frequent napping in case of longer exposure duration to light for both seasons. Sleep quality does not differ between summer and winter but is related to the duration of the exposure to bright light the day prior to the night.

  16. Problems of natural lighting for deepened buildings and underground premises under screen effect of high-rise construction

    Directory of Open Access Journals (Sweden)

    Larionova Kira

    2018-01-01

    Full Text Available The main rationale and objective of the submitted research work is to create a quality lighting environment in the premises of deepened buildings and below-ground structures under screen effect of high-rise construction (high-rise buildings. It is noted, that in modern megapolises, a deficiency of vacant urban territories leads to the increased density of urban development with increased amount of high-rise construction and tendency to increase efficiency in the use of underground space. The natural lighting of premises in underground buildings and structures is the most efficient way, but it can be implemented only under use of roof lighting system in the form of roof monitors or skylights. In this case the levels of indoor natural lighting will be affected with serious screening effect of high-rise buildings in surrounding development. Such an situation is not regulated, or even considered by the contemporary building Codes and Regulations on natural lighting of interiors. The authors offered a new formula for a daylight factor calculation with roof lighting system in the described cases. The results of theoretical calculations and experimental studies showed very similar values. This proved the truth of the offered formula and elaborated method of calculation on the basis of an offered hypothesis. It prooves, that it is possible to use some factor and guide points in the daylight factors design under system of side natural lighting in the same design for a system of roof lighting.

  17. Problems of natural lighting for deepened buildings and underground premises under screen effect of high-rise construction

    Science.gov (United States)

    Larionova, Kira; Stetsky, Sergey

    2018-03-01

    The main rationale and objective of the submitted research work is to create a quality lighting environment in the premises of deepened buildings and below-ground structures under screen effect of high-rise construction (high-rise buildings). It is noted, that in modern megapolises, a deficiency of vacant urban territories leads to the increased density of urban development with increased amount of high-rise construction and tendency to increase efficiency in the use of underground space. The natural lighting of premises in underground buildings and structures is the most efficient way, but it can be implemented only under use of roof lighting system in the form of roof monitors or skylights. In this case the levels of indoor natural lighting will be affected with serious screening effect of high-rise buildings in surrounding development. Such an situation is not regulated, or even considered by the contemporary building Codes and Regulations on natural lighting of interiors. The authors offered a new formula for a daylight factor calculation with roof lighting system in the described cases. The results of theoretical calculations and experimental studies showed very similar values. This proved the truth of the offered formula and elaborated method of calculation on the basis of an offered hypothesis. It prooves, that it is possible to use some factor and guide points in the daylight factors design under system of side natural lighting in the same design for a system of roof lighting.

  18. Tips for daylighting with windows

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alastair [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Selkowitz, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-10-01

    These guidelines provide an integrated approach to the cost-effective design of perimeter zones in new commercial buildings and existing building retrofits. They function as a quick reference for building designers, through a set of easy steps and rules-of-thumb, emphasizing “how-to” practical details. References are given to more detailed sources of information, should the reader wish to go further. The design method used in this document emphasizes that building decisions should be made within the context of the whole building as a single functioning system rather than as an assembly of distinct parts. This integrated design approach looks at the ramifications of each individual system decision on the whole building. For example, the decision on glazing selection will have an effect on lighting, mechanical systems, and interior design. Therefore, the entire design team should participate and influence this glazing decision—which typically rests with the architect alone. The benefit of an integrated design approach is a greater chance of success towards long-term comfort and sustained energy savings in the building.

  19. Ocean Tide Loading Computation

    Science.gov (United States)

    Agnew, Duncan Carr

    2005-01-01

    September 15,2003 through May 15,2005 This grant funds the maintenance, updating, and distribution of programs for computing ocean tide loading, to enable the corrections for such loading to be more widely applied in space- geodetic and gravity measurements. These programs, developed under funding from the CDP and DOSE programs, incorporate the most recent global tidal models developed from Topex/Poscidon data, and also local tide models for regions around North America; the design of the algorithm and software makes it straightforward to combine local and global models.

  20. DYNAMIC LOAD DAMPER MODELING

    Directory of Open Access Journals (Sweden)

    Loktev Aleksey Alekseevich

    2013-01-01

    Full Text Available The authors present their findings associated with their modeling of a dynamic load damper. According to the authors, the damper is to be installed onto a structure or its element that may be exposed to impact, vibration or any other dynamic loading. The damper is composed of paralleled or consecutively connected viscous and elastic elements. The authors study the influence of viscosity and elasticity parameters of the damper produced onto the regular displacement of points of the structure to be protected and onto the regular acceleration transmitted immediately from the damper to the elements positioned below it.

  1. Design-Load Basis for LANL Structures, Systems, and Components

    Energy Technology Data Exchange (ETDEWEB)

    I. Cuesta

    2004-09-01

    This document supports the recommendations in the Los Alamos National Laboratory (LANL) Engineering Standard Manual (ESM), Chapter 5--Structural providing the basis for the loads, analysis procedures, and codes to be used in the ESM. It also provides the justification for eliminating the loads to be considered in design, and evidence that the design basis loads are appropriate and consistent with the graded approach required by the Department of Energy (DOE) Code of Federal Regulation Nuclear Safety Management, 10, Part 830. This document focuses on (1) the primary and secondary natural phenomena hazards listed in DOE-G-420.1-2, Appendix C, (2) additional loads not related to natural phenomena hazards, and (3) the design loads on structures during construction.

  2. Lateral loadings on snubber assemblies

    International Nuclear Information System (INIS)

    Raphael, L.S.

    1981-01-01

    This paper examines the installation of snubber assemblies in power plants with respect to transverse or lateral loads as well as axial loads. Evaluation of the effects of low level, lateral loads was performed by analytical means. At higher loadings, the snubber assembly could no longer be treated as a column; therefore, the effects of lateral loadings was determined by test. The test consisted of applying both lateral and axial loads simultaneously. Results of both the analysis and the test showed that the application of lateral loads had a considerable effect on the snubber assemblies

  3. Fuel Load (FL)

    Science.gov (United States)

    Duncan C. Lutes; Robert E. Keane

    2006-01-01

    The Fuel Load method (FL) is used to sample dead and down woody debris, determine depth of the duff/ litter profile, estimate the proportion of litter in the profile, and estimate total vegetative cover and dead vegetative cover. Down woody debris (DWD) is sampled using the planar intercept technique based on the methodology developed by Brown (1974). Pieces of dead...

  4. HIV Viral Load

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  5. Loading device for incinerator

    International Nuclear Information System (INIS)

    Hempelmann, W.

    1983-01-01

    An incinerator for radioactive waste is described. Heat radiation from the incinerator into the loading device is reduced by the design of the slider with a ceramic plate and the conical widening of the pot, and also by fixing a metal plate between the pot and the floor. (PW) [de

  6. Side loading filter apparatus

    International Nuclear Information System (INIS)

    Reynolds, K.E.

    1981-01-01

    A side loading filter chamber for use with radioactive gases is described. The equipment incorporates an inexpensive, manually operated, mechanism for aligning filter units with a number of laterally spaced wall openings and for removing the units from the chamber. (U.K.)

  7. EQUATING FACULTY LOADS.

    Science.gov (United States)

    OOSTING, KENNETH W.

    AT ALPENA COMMUNITY COLLEGE, A NORMAL TEACHING LOAD FOR ANY FACULTY MEMBER IS 14-16 SEMESTER HOURS, WITH 75-125 STUDENTS AND 2-3 PREPARATIONS. VARIATIONS FROM THE SCHEDULE ARE IN ACCORDANCE WITH SPECIFIC FORMULAS RELATING TO TOTAL MEMBERS OF STUDENTS, NUMBERS OF PREPARATIONS, ASSIGNMENT TO ENGLISH COMPOSITION CLASSES, NEW COURSES, AND CLASSES…

  8. Probabilistic Load Flow

    DEFF Research Database (Denmark)

    Chen, Peiyuan; Chen, Zhe; Bak-Jensen, Birgitte

    2008-01-01

    This paper reviews the development of the probabilistic load flow (PLF) techniques. Applications of the PLF techniques in different areas of power system steady-state analysis are also discussed. The purpose of the review is to identify different available PLF techniques and their corresponding...

  9. Duration of load revisited

    DEFF Research Database (Denmark)

    Hoffmeyer, Preben; Sørensen, John Dalsgaard

    2007-01-01

    A duration of load study representing 13 years of testing was recently terminated. Preliminary results have been published over the years. This paper represents the final account of the study, which was focused on the influ-ence of moisture content on time to failure for structural timber subject...

  10. Robust surgery loading

    NARCIS (Netherlands)

    Hans, Elias W.; Wullink, Gerhard; van Houdenhoven, Mark; Kazemier, Geert

    2008-01-01

    We consider the robust surgery loading problem for a hospital’s operating theatre department, which concerns assigning surgeries and sufficient planned slack to operating room days. The objective is to maximize capacity utilization and minimize the risk of overtime, and thus cancelled patients. This

  11. Temoporfin-loaded liposomes

    DEFF Research Database (Denmark)

    Kuntsche, Judith; Freisleben, Ines; Steiniger, Frank

    2010-01-01

    . In contrast, if phospholipids with longer fatty acid chains (distearoylphosphatidylcholine/-glycerol) were used, phase transitions were well above body temperature even at high drug load. Size and thermal behavior were not distinctly influenced by the addition of pegylated lipids but cryo-electron microscopic...

  12. Distribution load forecast with interactive correction of horizon loads

    International Nuclear Information System (INIS)

    Glamochanin, V.; Andonov, D.; Gagovski, I.

    1994-01-01

    This paper presents the interactive distribution load forecast application that performs the distribution load forecast with interactive correction of horizon loads. It consists of two major parts implemented in Fortran and Visual Basic. The Fortran part is used for the forecasts computations. It consists of two methods: Load Transfer Coupling Curve Fitting (LTCCF) and load Forecast Using Curve Shape Clustering (FUCSC). LTCCF is used to 'correct' the contaminated data because of load transfer among neighboring distribution areas. FUCSC uses curve shape clustering to forecast the distribution loads of small areas. The forecast for each small area is achieved by using the shape of corresponding cluster curve. The comparison of forecasted loads of the area with historical data will be used as a tool for the correction of the estimated horizon load. The Visual Basic part is used to provide flexible interactive user-friendly environment. (author). 5 refs., 3 figs

  13. Load research manual. Volume 1. Load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  14. Daylight-driven photocatalytic degradation of ionic dyes with negatively surface-charged In{sub 2}S{sub 3} nanoflowers: dye charge-dependent roles of reactive species

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Suxiang [Xuchang University, Key Laboratory of Micro-Nano Materials for Energy Storage and Conversion of Henan Province, Institute of Surface Micro and Nano Materials, and School of Chemistry and Chemical Engineering (China); Cai, Lejuan, E-mail: 494169965@qq.com [Central China Normal University, Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, College of Chemistry (China); Li, Dapeng, E-mail: lidapengabc@126.com; Fa, Wenjun; Zhang, Yange; Zheng, Zhi [Xuchang University, Key Laboratory of Micro-Nano Materials for Energy Storage and Conversion of Henan Province, Institute of Surface Micro and Nano Materials, and School of Chemistry and Chemical Engineering (China)

    2015-12-15

    Even though dye degradation is a successful application of semiconductor photocatalysis, the roles of reactive species in dye degradation have not received adequate attention. In this study, we systematically investigated the degradation of two cationic dyes (rhodamine B and methylene blue) and two anionic dyes (methyl orange and orange G) over negatively surface-charged In{sub 2}S{sub 3} nanoflowers synthesized at 80 °C under indoor daylight lamp irradiation. It is notable to find In{sub 2}S{sub 3} nanoflowers were more stable in anionic dyes degradation compared to that in cationic dyes removal. The active species trapping experiments indicated photogenerated electrons were mainly responsible for cationic dyes degradation, but holes were more important in anionic dyes degradation. A surface-charge-dependent role of reactive species in ionic dye degradation was proposed for revealing such interesting phenomenon. This study would provide a new insight for preparing highly efficient daylight-driven photocatalyst for ionic dyes degradation.

  15. PLURALIZING NATURE

    DEFF Research Database (Denmark)

    Clemmensen, Thomas Juel

    2014-01-01

    Denmark is widely recognised for its democratic approach to planning and the idea of planning for the common good. This interest in the common good and common values seems also to be reflected in the way which nature restoration is planned and managed – one common nature directed by the public...... authorities. But nature restoration is far from being a neural undertaking. Just like any other type of heritage production it can be the source of dissonance – ‘our’ nature is not necessary ‘their’ nature. Often this dissonance is managed in ways, which are not particular sensitive to site......-specificity. As exemplified by the Skjern River Restoration Project (1999-2003), one interpretation of the landscape sometimes suppresses other valid interpretations neglecting its diverse history. However, evidence from Switzerland suggests that planning for the common good, in the case of nature restoration, does...

  16. A Statistical Model for Natural Gas Standardized Load Profiles

    Czech Academy of Sciences Publication Activity Database

    Brabec, Marek; Konár, Ondřej; Malý, Marek; Pelikán, Emil; Vondráček, Jiří

    2009-01-01

    Roč. 58, č. 1 (2009), s. 123-139 ISSN 0035-9254 R&D Projects: GA AV ČR 1ET400300513 Institutional research plan: CEZ:AV0Z10300504 Keywords : disaggregation * generalized additive models * multiplicative model * non-linear effects * segmentation * semiparametric regression model Subject RIV: JE - Non-nuclear Energetics, Energy Consumption ; Use Impact factor: 1.060, year: 2009

  17. Ice load reducer for dams : laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Lupien, R.; Cote, A.; Robert, A. [Institut de Recherche d' Hydro-Quebec, Varennes, PQ (Canada)

    2009-07-01

    Many studies have focused on measuring static ice loads on various hydraulic structures in Canada. This paper discussed a Hydro-Quebec research project whose main purpose was to harmonize the ice thrust value in load combinations for use in general hydraulic works or for specific cases. The objectives of the project were to obtain a better understanding of existing data and to characterize sites and their influence on ice thrust; study the structural mechanisms involved in the generation of ice thrust, their consequences on the structural behaviour of ice and the natural mitigating circumstances that may be offered by ice properties or site operating procedures; and examine the relevance of developing an ice load reducer for works that might not fit the harmonized design value. The paper presented the main research goals and ice load reducer goals, with particular focus on the four pipe samples that were planned, built and tested. The experimental program involved checking the pipe shape behaviour in terms of flexibility-stiffness; maximum deformations; maximum load reduction; permanent deformations; and, ability to shape recovering. The testing also involved examining the strength versus strain rate; creep versus strain rate; and creep capacity under biaxial state of tension and compression. It was concluded that the two phenomena involved in generation of ice thrust, notably thermal expansion and water level changes, had very low strain rates. 8 refs., 2 tabs., 16 figs.

  18. Natural Philosophy

    OpenAIRE

    Blair, Ann M.

    2006-01-01

    Natural philosophy” is often used by European historians as an umbrella term to designate the study of nature before it can easily be identified with what we call “science” today, to avoid the modern and potentially anachronistic connotations of that term. But “natural philosophy” (and its equivalents in different languages) was also an actor's category, a term commonly used throughout the early modern period and typically defined quite broadly as the study of natural bodies. As the central ...

  19. Dissonant Nature

    DEFF Research Database (Denmark)

    Clemmensen, Thomas Juel

    2013-01-01

    Nature restoration is far from being a neural undertaking. Just like any other type of heritage production it can be the source of dissonance – ‘our’ nature is not necessary ‘their’ nature. Often this dissonance is managed in ways, which are not particular sensitive to site-specificity. As exempl...... and allows for multiple interpretations to coexist. Evidence can be found in the Re-naturalization of River Aire (2002-2015), a restoration project, which reveals approaches that could be labelled landscape architecture specific....

  20. Temporal naturalism

    Science.gov (United States)

    Smolin, Lee

    2015-11-01

    Two people may claim both to be naturalists, but have divergent conceptions of basic elements of the natural world which lead them to mean different things when they talk about laws of nature, or states, or the role of mathematics in physics. These disagreements do not much affect the ordinary practice of science which is about small subsystems of the universe, described or explained against a background, idealized to be fixed. But these issues become crucial when we consider including the whole universe within our system, for then there is no fixed background to reference observables to. I argue here that the key issue responsible for divergent versions of naturalism and divergent approaches to cosmology is the conception of time. One version, which I call temporal naturalism, holds that time, in the sense of the succession of present moments, is real, and that laws of nature evolve in that time. This is contrasted with timeless naturalism, which holds that laws are immutable and the present moment and its passage are illusions. I argue that temporal naturalism is empirically more adequate than the alternatives, because it offers testable explanations for puzzles its rivals cannot address, and is likely a better basis for solving major puzzles that presently face cosmology and physics. This essay also addresses the problem of qualia and experience within naturalism and argues that only temporal naturalism can make a place for qualia as intrinsic qualities of matter.